Fire Detection Systems
Product catalog 2013
Valid from April 2013
Fire Detection Systems
Contents
1
2
3
4
5
6
7
8
9
General Hints
3-6
Foreword
Contact
Abbreviations
Symbols
3
4
5
6
Control Panels
1
2
8-31
IQ8Control
Extinguishing System
8-27
28-31
3
Power Supply
34-38
4
Power Supply Units
Voltage Converters
Batteries (rechargeable)
Accessories
34-35
36
37
38
Display and Operating Units
40-45
LED Indicator Panel
LCD Indicator Panel
System 3000
40
41
42-45
Network Technology
48-56
essernet
Multiprotocol Gateway
48-52
53-56
Management Systems
58-69
WINMAGplus
WINMAGLite
Difference WINMAGLite vs. WINMAGplus
58-67
68
69
Automatic Detectors
72-104
Detector Series 9000 Conventional
Series IQ8Quad (Intelligent Addressable)
Detectors for Hazardous Areas
Base Series IQ8Quad
Accessories
72
73-84
85-89
90
91-104
Manual Call Points
106-120
Large Design - ABS
Large Design - Aluminum
Large Design - Accessories
Special Design
106-109
110-112
113-116
117-120
Transponders
122-132
esserbus
122-132
10 Wireless Components
134-140
Wireless Modules
134-140
5
6
7
8
9
10
11
12
13
14
15
1
Contents
11 Detectors for Special Applications
Flame and Heat Detector
Air Duct Detector
Line Heat Detectors
Line Smoke Detectors
Aspirating Smoke Detectors
Accessories
12 Alarm Devices
188-208
188-197
198-206
207-208
13 Door Release System
210-219
14 Installation & Service
Installation Accessories
Housings
Services
15 Appendix
Planning Guide
Orders Forms
Part Number Index
Index
www.hls-austria.com
142-146
147-149
150-158
159-165
166-184
185
IQ8Alarm
Conventional
Remote Indicators
Automatic Door Systems
Door Holding Devices
Triggering Devices
2
142-185
210-212
213-217
218-219
222-232
222-228
229-231
232
234-250
234
235-240
241-243
244-250
Foreword
General Hints
Introduction
Dear business partners,
you are looking at your personal issue of our 2013 product catalog. We would be happy
if you could take the time to assure yourself of our comprehensive product range. Your
satisfaction has been our top priority ever since our company was founded. Because of
this, all changes and innovations made meet our basic principle to only offer products
of maximum quality at a good price-performance ratio to you.
1
2
The high level of customer satisfaction which we have maintained for years now is
represented by renowned references from all over the world such as:
3
4
5
Office Center Rivergate, Vienna, Austria
•
Power Plant Belchatow, Poland
•
Megasport Arena Kodinka, Russia
6
The success of these extraordinary projects is tied closely to your success. We would
therefore like to further extend our cooperation together with you under the motto
"Safety is a matter of partnership". Use this possibility of talking to us and tell us your
suggestions and wishes so we can build the future together in this more and more
difficult market environment.
7
8
Please visit our website www.hls-austria.com and find all information for downloading.
We are looking forward to our continued mutual success!
9
Your Honeywell Life Safety Austria Team
10
11
12
13
14
15
3
General Hints
Contact
Representative Offices of Honeywell Life Safety Austria
Headquarters
Honeywell Life Safety Austria GmbH
Lemböckgasse 49
1230 Vienna, Austria
Phone:+43 1 600 6030
Fax: +43 1 600 6030-900
E-mail: [email protected]
Internet: www.hls-austria.com
Czech Republic / Slovakia
Representative Office of Honeywell Life Safety
Austria GmbH
V Parku 2326/18
148 00 Prague 4 - Chodov, Czech Republic
Phone: +420 242 442 280
Fax: +420 242 442-119
E-mail: [email protected]
Internet: www.hls-czech.com
Poland
Representative Office of Honeywell Life Safety
Austria GmbH
Ul.Marynarska 15, bud. New City
02-674 Warsaw, Poland
Phone: +48 22 313 09 70
Fax: +48 22 313 09 79
E-mail: [email protected]
Internet: www.hls-poland.com
Romania
Honeywell Life Safety Romania S.R.L.
Salcâmilor str. 2 bis
305500 Lugoj, Romania
Phone: +40 256 35 00 00
Fax: +40 256 35 49 53
E-mail: [email protected]
Internet: www.hls-romania.com
Russia
Representative Office of Honeywell Life Safety
Austria GmbH
8th floor, Kievskaya str., 7
121059 Moscow, Russia
Phone: +7 495 231 26 92
Fax: +7 495 795 08 81
E-mail: [email protected]
Internet: www.hls-russia.com
Ukraine
Representative Office of Honeywell Life Safety
Austria GmbH
Office Center „IRVA“, Block A
Radyscheva str. 10/14
03680 Kiev, Ukraine
Phone: +380 44 351 15 50
Fax: +380 44 351 15 51
E-mail: [email protected]
Internet: www.hls-russia.com
Turkey
Representative Office of Honeywell Life Safety
Austria GmbH
Bostancı İbrahimağa Sokak
Somal Plaza Floor 5, No:10
34740 Suadiye Kadıköy/Istanbul, Turkey
Phone: +90 216 410 61 41
Fax: +90 216 410 43 97
E-mail: [email protected]
Internet: www.hls-turkey.com
4
www.hls-austria.com
Honeywell Life Safety Romania S.R.L.
Upground - BOC Office Building
3 George Constantinescu, Building A, 4th Floor, District 2
020339 Bucharest, Romania
Phone: +40 31 224 36 10
Fax: +40 21 204 81 65
E-mail: [email protected]
Internet: www.hls-romania.com
Abbreviations
General Hints
Abbreviations
1
The list below provides a brief explanation of various Abbreviations used in this product guide.
2
acc.
approx.
=
=
according to
approximately
ARS
=
DIBT
=
MCP
=
manual call point
aspirating detector
MFAB
MM
=
=
master box
micromodule
3
German Institut for
OMF
=
operating module front
4
dual in line
German Institut for
PAM
=
series 9200
pcb
=
printed circuit board
Standardization
pcs.
=
pieces
PLC
PM
=
=
programmable logic control
delay and verify functions
PTB
=
National Institute of Natural
Technical Approvals
DIL
DIN
=
=
DIP
=
dual in parallel
DKC
DRS
=
=
display keyboard card
digital receiving station
EDD
EDP
EL
=
=
=
series 9000
Esser Data Protocol
Line voltage
5
6
7
EN
=
EOL resistor =
European Norm
end-of-line resistor
Ex
explosion proof
=
and Engineering Sciences
RIP
=
remote indicating panel
ROR
=
rate-of-rise heat detector
SHV
=
smoke heat ventilation
=
module
surface mounted
technology
SMD
FACP
FAS
=
=
fire alarm control panel
fire alarm system
FBF
FD
=
=
firepanel for Fire Brigade
fire detection
FDC
FDOP
FDS
=
=
=
FSA
=
HU
=
SOC
SZI
=
=
switch-on control
single zone indicator
fire detection panel
fire brigade panel
fire detection system
TAL
=
technical alarm module
TM
=
coincidence detection
door release system
USB
UV
=
=
universal serial bus
ultra-violet
VDE
=
VdS
=
VGA
VPP
=
=
Association for Electrical,
Electronic and Information
Technologies
Association of German
Property Insurance
Companies
video graphics array
voltage peak-peak
used for 19 inch rack e.g. "6HU"
1 HU = 44.45mm
I/O
IP
IR
=
=
=
input/ output
ingress protection rating
infrared
LAN
LCD
LED
LF
LPCB
=
=
=
=
=
local area network
liquid cristal display
light emitting diode
low frequency
LRS
=
8
9
10
11
12
13
14
15
Loss Prevention Certification
Board
high sensitivity aspiration
detector
5
General Hints
Symbols
Symbols used
=
List of contents which the part number includes
=
Packing unit
=
Information, important notice
such as special versions, dependencies etc.
=
Available as from...
IP type of protection
The type of protection indicates the suitability of electric operating materials (for example, devices, lights and installation material)
against solid foreign objects and for various ambient conditions.
Levels of protection for protection from touch and foreign bodies (1st digit)
Digit
Protection from touch
Protection from foreign bodies
0
No protection
No protection
1
Protection from large-sized body parts
(diameter 50 mm)
Large foreign bodies
(diameter from 50 mm)
2
Finger protection
(diameter 12 mm)
Medium-size foreign bodies
(diameter from 12.5 mm)
3
Tools and wires
(diameter from 2.5 mm)
Small foreign matter
(diameter from 2.5 mm)
4
Tools and wires
(diameter from 1 mm)
Grain-shaped foreign matter
(diameter from 1 mm)
5 (K)
Wire protection (as IP 4) dust-protected
Dust accumulation
6 (K)
Wire protection (as IP 4) dust-proof
No ingress of dust
Levels of protection for the protection from water (2nd digit)
Digit
Protection from water
0
No protection
1
Protection from vertically dripping water
2
Protection from diagonally (15°) falling drip water
3
Protection from falling spray water up to 60°, against the vertical
4
Protection against splashing water
5
Protection from hose water (nozzle) from any angle
6
Protection from strong hose water (flooding)
7
Protection from temporary submersion
8
Protection from permanent submersion
Example:
IP64: Completely dust-proof - protected against splashing water - nearly leak-proof.
6
www.hls-austria.com
1
2
3
4
5
6
7
8
9
10
Control Panels
IQ8Control
Extinguishing System
8-27
28-31
11
12
13
14
15
7
Control Panels
IQ8Control
IQ8Control C / Intelligent Addressable
Features
Approval: VdS, CNBOP, BOSEC
• Max. two micromodules
• Max. two esserbus analog loop modules
• Short circuit and open circuit resistant loop opera­
The IQ8Control C as an efficient fire alarm control panel for the property supervision of ​
small to mid-sized objects facilitates simultaneous detection, control and alarm signaling ​
both on the analogous ring as well as on the spur.
Within the multifunctional IQ8Control C panel, the operation type (powered-loop or non-​
powered-loop) can be selected via a jumper located on the control panel power supply unit.
Depending on which loop operation type has been selected, the respective loop module/​
modules are required.
tion
• Loop installation with I-Y(ST)Y 0.8 mm cable for a ​
maximum length of 3.5 km
• Up to 127 esserbus devices (fire detectors r​ espectively manual call points)/detector zones ​per loop
• Up to 32 esserbus transponders per loop/​opera-
Technical Data
• Operation types TM and PM as per DIN VDE 0833 ​
Rated voltage
Rated frequency
Rated current
Quiescent current
tion of wireless components (see chapter ​10)
- 2 to avoid unwanted alarms being triggered
• Fire brigade operating panel and alarm transmis­
sion unit interface on the peripheral module
• Three common relays, freely programmable, ​
•
•
•
•
•
•
•
•
•
•
monitored, floating for up to 24 V DC/1A (on the ​
peripheral module)
TTY or RS 485, RS 232 interface
Integration in the short circuit and open circuit ​
resistant essernet network with up to 31 fire ​
detection panels depends on transmission rate
Connection to graphical supervisor WINMAG via ​
serial essernet interface (SEI)
Operating panel with alphanumerical display
8 x 40 backlit LCD display
Event memory for up to 10,000 events
All System 8000 micromodules are compatible
Printer interface for internal printer
Two batteries with monitoring circuit
Monitored input for external power supply unit
Current consumption for ext. devices
Battery capacity
Ambient temperature
Storage temperature
Type of protection
Housing
Color
Weight
Dimensions
CE certificate
- The IQ8Control fire detection panels are fully compatible with FACP 8000 panels within ​
essernet applications
- FACP 8000 micromodules are also compatible with IQ8Control devices
- Housing form and color comply with the FACP 8000 generation
- The IQ8Control panels can only be programmed with the tools 8000 software solution (part no. ​
789861) and the field bus interface (part no. 789862.10) or directly via USB with the RS-232 ​
interface (part no. 769828), with the field bus interface or the RS232 interface.
Additional features for powered loop
• Max. 2 analog powered loop modules
• BUS powered, synchronously controlled, acoustic ​
alarm signalling devices as per DIN EN 54-3 with ​
alarm tone as per DIN 33404
• Up to 48 powered loop base sounders (series ​
9200) per loop
• Up to 32 powered loop IQ8Alarm per loop
• Up to 48 IQ8Quad with alarm device per loop
Connection example
8
www.hls-austria.com
230 V AC
50 ... 60 Hz
0.35 A (standard); 0,7 A (powered loop)
approx. 215 mA (basic configuration without operating ​
unit)
approx. 230 mA (basic configuration with operating ​
unit)
2 A
2 x 12 Ah, 2 x 24 Ah in extension housing
-5 °C ... 45 °C
-5 °C ... 50 °C
IP 30
ABS, 10% glass fibre reinforced, V - 0
gray similar to Pantone 538
approx. 6.5 kg
W: 450 mm H: 320 mm D: 185 mm
0786-CPD-20827
Control Panels
IQ8Control
1
IQ8Control C Design and Order Diagram
2
1.
Choice of the
housing type
3
IQ8ControlC standard housing 808003
4
IQ8ControlC for 19” cabinet 808139
Slot for one micromodule as standard
2.
Choice of the
control panel
modules
(only 1 module at a time)
5
772478
Extension module with
one additional micromodule slot
772477
Peripheral module with
one additional micromodule slot
772479
Peripheral module
6
7
3.
Choice of the
micromodules
4.
Choice
of the
operating front*
804382.D0
Analog loop module powered loop
784382.D0
Analog loop module
771670
Master box interface
module
784840.10
essernet module 62.5kBd
787531
3-relay module
784842
RS 232/TTY
serial interface module
784385
Master box interface
module
784841.10
essernet module 500kBd
787532
3-relay
common fault module
8
9
787530
4-relay module
10
language codes available:
01 Germany
02 England
03 Italy
04 Portugal
05 Poland
06 Spain
07 Austria
08 Netherlands
09 Czech Republic
10 Russia
11 Hungary
12 Denmark
13 Sweden
14 Croatia
15 France
16 Slovakia
17 Switzerland / French
18 Romania
19 Slovenia
20 Turkey
21 Greece
22 Belgium / Flemish
23 Belgium / Walloon
25 Arabic / English
27 Serbian
11
7860_ _
Operating front
7861_ _
Operating front w.
SZI f. 64 detector
zones
7868_ _
Operating front with
printer,
w/o take-up reel*
7863_ _
Operating front for
printer,
w. take-up reel**
786000
SZI front for 192
detector zones
786100
Filler panel front,
neutral for
IQ8Control C/M
12
13
7864_ _
7865_ _
Operating front w.
Operating front with 1/4 VGA display &
1/4 VGA display
SZI for 64 zones
7869_ _
Operating front w. 1/4 VGA
display, printer , w/o take-up reel
788093
19” rack mounting kit for
SZI 192 detector zones
14
All operating fronts, except SZI 192 detector zones are suitable for both housing types
*Space for only 1 battery **Requires an additional extension housing
15
5.
Choice of a
extension housing
(optional)
789300
Battery extension housing
789302
Extension housing for SZI
192 detector zones
789301
Extension housing for batteries and
SZI 192 detector zones
*Please note, not all variants are available in all languages! Please contact your sales representative for availability.
9
Control Panels
IQ8Control
Control Panels
808003
Fire alarm control panel IQ8Control C
1
Basic design.
The operating front must be ordered separately and is not included in the price.
Housing with standard rear panel and front frame for operating panel fronts, interface board, ​
power supply module, system software.
808139
Fire alarm control panel IQ8Control C for 19" cabinet
1
As 808003 but 19" version (7 HU) for upright cabinet installation.
The operating front must be ordered separately and is not included in the price.
FACP 808003 IQ8Control C, including 19" installation frame and flat cable for 19" installation ​
750707.
10
www.hls-austria.com
Control Panels
IQ8Control
Accessories FACP IQ8Control C
1
789300
2
Battery extension housing
1
Extension housing for additional batteries.
Technical Data
Ambient temperature
Storage temperature
Type of protection
Housing
Weight
Dimensions
3
-5 °C ... 45 °C
-10 °C ... 50 °C
IP 30
ABS, 10% glass fiber reinforced, V - 0
approx. 5 kg (without battery)
W: 450 mm H: 320 mm D: 185 mm
4
Batteries are not included and must be ordered separately.
5
Housing complete with battery rear panel, connecting cable for battery, mounting positions for 2 ​
x 12V/24Ah batteries. Neutral front and material for attaching to the existing panel housing, ​
battery connecting cables, 800 mm.
6
Assembling the housing parts
Take off the
4 standard covers.
Insert the
2 connecting elements.
Put the 2 housings
on top of each other
and push them together.
7
8
9
10
1.
2.
3.
11
Connection between the central housing and the extension housing
789301
Extension housing for batteries and SZI 192 detector zones
12
1
Technical Data
Quiescent current
Current consumption
Ambient temperature
Type of protection
Housing
Color
Weight
Dimensions
approx. 5 mA
1.5 mA when LED activated
-5 °C ... 45 °C
IP 30
ABS, 10% glass fiber reinforced, V - 0
gray similar to Pantone 538
approx. 5.5 kg (without battery)
W: 450 mm H: 320 mm D: 185 mm
13
14
This housing cannot be used if an operating module front with single zone indicator unit for 64 ​
zones is already fitted. Batteries are not included and must be ordered separately.
A single zone indicator unit can only be used in connection with an operating module front.
15
Housing complete with battery rear panel, connecting cable for batteries, mounting positions for ​
2 x 12V/24Ah batteries, single zone indicator front for 192 detector zones and material for ​attaching to the existing panel housing.
11
Control Panels
789302
IQ8Control
Extension housing for SZI 192 detector zones
1
The housing can be used to mount additional modules, e.g. an esserbus transponder.
Technical Data
Quiescent current
Current consumption
Ambient temperature
Type of protection
Housing
Color
Weight
Dimensions
approx. 5 mA
1.5 mA when LED activated
-5 °C ... 45 °C
IP 30
ABS, 10% glass fiber reinforced, V - 0
gray similar to Pantone 538
approx. 5 kg
W: 450 mm H: 320 mm D: 185 mm
This housing cannot be used if an operating module front with single zone indicator unit for 64 ​
zones is already fitted. A SZI unit can only be used in combination with an operating module ​
front.
Housing complete with standard rear panel, single zone indicator front for 192 detector zones ​
and material for attaching to the existing panel housing.
12
www.hls-austria.com
Control Panels
IQ8Control
1
IQ8Control M / Intelligent Addressable
Features
Approval: VdS, CNBOP, BOSEC
• Max. five micromodules, with peripheral module ​
VdS-system recognition: S 294050
• Max. seven esserbus analog loops, with extension ​
The IQ8Control M as an efficient fire alarm control panel for the property supervision of ​
mid-sized to large objects, facilitates simultaneous detection, control and alarm signalling ​
both on the analogous ring as well as on the spur.
The loop operation type of the panel (powered-loop or non-powered-loop) can be selected ​
via a jumper located on the power supply card.
Depending on which loop operation type has been selected, the respective analog module/​
modules should be used.
772477
module 772476
• Short circuit and open circuit tolerant loop opera­
tion
• Loop installation with I-Y(ST)Y 0.8 mm cable for a ​
maximum length of 3.5 km
• Up to 127 esserbus devices (fire detectors r​ espectively manual call points)/detector zones ​per loop
• Up to 32 esserbus transponders per loop/​opera-
Technical Data
• Operation types TM and PM as per DIN VDE 0833 ​
Rated voltage
Rated frequency
Rated current
Output voltage
Quiescent current
tion of wireless components (see chapter ​10)
- 2 to avoid unwanted alarms being triggered
• Fire brigade operating panel and transmission ​
interface on the peripheral module
• Three common relays, freely programmable, ​
•
•
•
•
•
•
•
•
•
•
monitored, floating for up to 30 V DC/1A (on the ​
peripheral module)
TTY or RS485 or RS 232 interface
Integration in the short circuit and open circuit ​
resistant essernet network with up to 31 fire ​
detection panels depends on transmission rate
Connection to graphical supervisor WINMAG via ​
serial essernet interface (SEI)
Operating panel with alphanumerical display
4 x 80 backlit LCD display
Event memory for up to 10,000 events
All Systems 8000 micromodules are compatible
Printer interface for internal printer
Two batteries with monitoring circuit
Monitored input for external power supply unit
Additional features for powered loop
• Max. 6 analog powered loops and expandable up ​
to 124 power loops
• BUS supplied, synchronously controlled, acoustic ​
alarm signalling devices as per DIN EN 54 - 3 with ​
alarm tone as per DIN 33404
• Up to 48 powered loop base sounders (series ​
9200) per loop
• Up to 32 powered loop IQ8Alarm per loop
• Up to 48 IQ8Quad with alarm device per loop
Current consumption for ext. devices
Battery capacity
Ambient temperature
Storage temperature
Type of protection
Housing
Color
Weight
Dimensions
CE certificate
2
3
4
5
230 V AC
50 ... 60 Hz
0.35 A (standard); 0,7 A (powered loop)
12 V DC
approx. 215 mA (basic configuration without operating ​
unit)
approx. 230 mA (basic configuration with operating ​
unit)
2 A
max. 2 x 12 V/24 Ah
-5 °C ... 45 °C
-10 °C ... 50 °C
IP30
ABS, 10% glass fiber reinforced, V - 0
gray similar to Pantone 538
approx. 11.5 kg
W: 450 mm H: 640 mm D: 185 mm
0786-CPD-20827
6
7
8
9
- The IQ8Control fire detection panels are fully compatible with FACP 8000 panels within ​
essernet applications
- FACP 8000 micromodules are also compatible with IQ8Control devices
- Housing form and color comply with the FACP 8000 generation
- The IQ8Control panels can only be programmed with the tools 8000 software solution (part no. ​
789861) and the field bus interface (part no. 789862.10) or directly via USB with the RS-232 ​
interface (part no. 769828), with the field bus interface or the RS232 interface.
10
11
external equipment
12
12V DC
Fiber optic converter
essernet
Loop length max. 1 km
(with repeater max. 3 km)
Repeater
13
esserbus-PLus
Loop length max. 3.5 km
IQ8Control C
IQ8Control M
Management system
WINMAG
14
esserbus transponder
15
Application example
13
Control Panels
IQ8Control
IQ8Control M Design and Order Diagram (Basic Design)
1.
Choice of the
housing type
Wall housing
808004
IQ8Control M for 19" cabinet
808219
Slot for one micromodule as standard
2.
Choice of the
control panel
modules
2 Extension modules
or
1 Extension module
+
1 Peripheral module
3.
Choice of the
micromodules
4.
Choice
of the
operating front*
772478
Extension module
with one additional
micromodule slot
772476
Extension module with
three additional
micromodule slots
772479
Peripheral module
772477
Peripheral module
with one additional
micromodule slot
804382.D0
Analog loop module powered loop
784382.D0
Analog loop module
771670
Master box interface
module
784840.10
essernet module 62,5kBd
787531
3-relay module
784842
RS 232/TTY
Serial interface module
784385
Master box interface
module
784841.10
essernet module 500kBd
787532
3-relay
common fault module
787530
4-relay module
language codes available:
01 Germany
02 England
03 Italy
04 Portugal
05 Poland
06 Spain
07 Austria
08 Netherlands
09 Czech Republic
10 Russia
11 Hungary
12 Denmark
13 Sweden
14 Croatia
15 France
16 Slovakia
17 Switzerland / French
18 Romania
19 Slovenia
20 Turkey
21 Greece
22 Belgium / Flemish
23 belgium / Walloon
25 Arabic / English
27 Serbian
7860xx
Operating front
7861xx
Operating front w.
SZI f. 64 detector
zones
7868xx
Operating front
with printer
7864xx
Operating front
with 1/4 VGA
display
7865xx
Operating front w.
1/4 VGA display &
SZI for 64 zones
7869xx
Operating front w. 1/4 VGA
display, printer , w/o take-up reel
7863xx
Operating front for
printer,
w. take-up reel*
786000
SZI front for 192
detector zones
786100
Filler panel front,
neutral
788093
19” rack mounting kit for
SZI 192 detector zones
All operating fronts, except SZI 192 detector zones are suitable for both housing types
*Requires an additional extension housing
5.
Choice of a
extension housing
(optional)
789303
Extension housing f. additional modules
789304
Extension housing incl. printer
with paper take-up reel
*Please note, not all variants are available in all languages! Please contact your sales representative for availability.
14
www.hls-austria.com
Control Panels
IQ8Control
1
Control Panels
808004
2
Fire alarm control panel IQ8Control M
1
Basic design.
The operating front must be ordered separately and is not included in the price.
3
Housing with rear panel and front frame for operating panel fronts, interface board, power ​
supply module and system software.
4
5
808219
Fire alarm control panel IQ8Control M for 19" cabinet
1
As 808004 but 19" version (7HU) for upright cabinet installation.
6
The operating front must be ordered separately and is not included in the price.
FACP IQ8Control M 808004, including 19" mounting frame and flat cable for 19" installation ​
750707.
7
8
789303
Extension housing
9
1
The standard extension housing can be used to mount additional modules, e.g. esserbus ​
transponders.
10
Technical Data
Features
• For the installation of up to 6 transponders and FO ​
converters with installation kit 788650.
Ambient temperature
Storage temperature
Type of protection
Housing
Color
Weight
Dimensions
-5 °C ... 45 °C
-10 °C ... 50 °C
IP30
ABS plastic, 10% glass fiber reinforced, V - 0
gray similar to Pantone 538
approx. 5 kg
W: 450 mm H: 320 mm D: 185 mm
11
12
Housing complete with standard rear panel, neutral front and material for attaching to the e​ xisting control panel housing.
13
Assembling the housing parts
Take off the
4 standard covers.
Insert the
2 connecting elements.
Put the 2 housings
on top of each other
and push them together.
14
15
1.
2.
3.
Connection between the central housing and the extension housing
15
Control Panels
IQ8Control
IQ8Control C/M
IQ8Control C/M Operating Fronts
Features
• alphanumerical display
• 2 x 20 backlit LCD display
ESSER - front (786001, 786101, 786301, 786401, 786501, 786801 and 786901) is also ​
available with the respective country specification - except the special versions. When ordering, ​
please fill in the last two digits with the specific language code.
(Not all variants are available in all languages. Please contact your sales representative for ​
details)
Example:
The German version of the standard operating front C/M would have the Part No. 7860-01.
For the Dutch version, the number would have to be changed to Part No. 7860-08.
Specific language code:
01 German (Germany)
02 English
03 Italian
04 Portuguese
05 Polish
06 Spanish
07 German (Austria)
08 Dutch
09 Czech
10 Russian
11 Hungarian
12 Danish
13 Swedish
14 Croatian
15 French (France)
16 Slovakian
17 French (Switzerland)
18 Romanian
20 Turkish
21 Greek
22 Flemish (Belgium - Dutch)
23 Walloon (Belgium - French)
25 Arabic / English
27 Serbian
52 Chinese
786002
Operating front, English
1
786102
Operating front with single zone indication 64, English
1
Technical Data
Current consumption
16
www.hls-austria.com
single zone indication: per activated LED 1.5mA
Control Panels
786802
IQ8Control
1
Operating front w. printer, w/o take-up reel, English
1
Available until Q4/2013
2
3
4
786302
Operating front for printer and w. take-up reel, English
1
The printer kit with paper take-up reel (Part No. 784892) must be ordered separately.
5
Available until Q4/2013
6
7
786402
Operating module front with 1/4 VGA display, English
8
1
Technical Data
Resolution
320 x 240 pixels
9
Remote diagnosis is not possible if a two-line extra text is programmed.
10
786502
11
Operating module front 1/4 VGA and SZI for 64 zones, English
1
Technical Data
Current consumption
Resolution
single zone indication: per activated LED 1.5mA
320 x 240 pixels
12
Remote diagnosis is not possible if a two-line extra text is programmed.
13
14
786902
Operating module front with 1/4 VGA display and printer, English
1
Technical Data
Current consumption
Resolution
15
printer: 45mA
320 x 240 pixels
Remote diagnosis is not possible if a two-line extra text is programmed.
Available until Q4/2013
17
Control Panels
786000
IQ8Control
SZI front for 192 detector zones
1
Technical Data
Quiescent current
Current consumption
approx. 5 mA
single zone indication: per actuated LED 1.5mA
Including insertable foils with country-specific version.
786100
Filler panel front, neutral for IQ8Control C/M
1
788093
19” rack mounting kit for SZI 192 detector zones
1
7 HU for upright cabinet mounting.
Technical Data
Quiescent current
Current consumption
approx. 5 mA
1.5 mA per actuated LED
772445 mounting frame
786000 SZI front for 192 detector zones, including insertable foils with country-specific version
18
www.hls-austria.com
Control Panels
IQ8Control
1
Control Panel Modules for IQ8Control C/M
772479
Peripheral module
2
1
The peripheral module contains a fire brigade operating panel interface as well as an alarm ​
transmission unit interface and three freely programmable, optionally monitored or up to ​
30 V DC floating common relays. The peripheral module can only be used on system ​
terminal 1 of the control panel interface board.
3
Technical Data
Quiescent current
4
approx. 15 mA
Only one 772477/78/79 module can be plugged onto the interface board.
772477
5
Peripheral module with one additional micromodule slot
1
As 772479 but with one additional micromodule slot. The peripheral module can only be ​
used on system terminal 1 of the control panel interface board.
6
Technical Data
Quiescent current
approx. 15 mA (without micromodule)
7
Only one 772477/78/79 module can be plugged onto the basic module.
772478
8
Extension module with one additional micromodule slot
1
The extension module is plugged onto the interface board of the control panel. The exten­
sion module can only be used on system terminal 1 of the control panel interface board.
9
Technical Data
Quiescent current
approx. 5 mA (without micromodule)
Only one 772477/78/79 module can be plugged onto the interface board.
772476
10
Extension module with 3 additional micromodule slots
11
1
The extension module is plugged onto the interface board of the control panel. This exten­
sion module can be used on plug connectors 1 and 2 of the basic control panel module.
Technical Data
Quiescent current
12
approx. 5 mA (without micromodule)
The 772476 extension module can only be used in the IQ8Control M fire alarm control panel.
13
14
15
19
Control Panels
IQ8Control
Micromodules for IQ8Control C/M
784382.D0
Analog loop module
1
Single loop circuit module for up to 127 Series 9200/IQ8Quad intelligent fire detectors or ​
bus devices, divisible into 127 zones.
Technical Data
Quiescent current
804382.D0
approx. 25 mA
Analog loop module powered loop
1
Single loop circuit module for up to 127 bus devices, and esserbus PLus (powered loop) ​
devices according to the load factor. Series 9200/IQ8Quad intelligent fire detectors and ​
esserbus transponders (Part No. 80xxxx) or addressable sounders and powered loop base ​
sounders.
Technical Data
Quiescent current
approx. 25 mA
Powered loop compatible only with IQ8Control and FlexES.
784385
Master box interface module
1
Single master box interface module for activating and processing acknowledgement ​
signals from master boxes; programmable as constant or pulsed master box activation.
Technical Data
Quiescent current
771670
approx. 15 mA
Master box interface module
1
Single master box interface module for activating and processing acknowledgement ​
signals from master boxes; programmable as constant or pulsed master box activation, for ​
potential-free triggering.
Technical Data
Quiescent current
784842
approx. 15 mA
RS 232/TTY serial interface module
1
Serial interface module with optional RS 232 or TTY type, for operating external devices ​
such as external printers, printers, modems for remote diagnosis.
Technical Data
Quiescent current
787530
approx. 35 mA (RS 232)
approx. 55 mA (TTY)
4-relay module
1
4-relay module with freely programmable output functions, each of which can operate as ​
an NC or NO contact (not monitored) for potential-free activation.
Technical Data
Quiescent current
Contact load relay
787531
approx. 10 mA
max. 30 V DC/1 A
3-relay module
1
3-relay module with output functions which can be programmed either as NC or NO ​
contacts, 3 x latching "monitored" relay outputs.
Technical Data
Quiescent current
Contact load relay
20
www.hls-austria.com
approx. 5 mA
max. 30 V DC/1 A
Control Panels
787532
IQ8Control
1
3-relay common fault module
1
3-relay module with pre-set functions such as common fault, 2 x freely programmable ​
monitored relay outputs.
2
Technical Data
Quiescent current
Contact load relay
approx. 15 mA
max. 30 V DC/1 A
3
4
5
6
7
8
9
10
11
12
13
14
15
21
Control Panels
IQ8Control
Accessories for IQ8Control C/M
804880
Kit DCF77 radio time module for IQ8Control & FlexES Control
1
Used in conjunction with the Kit DCF77 allows radio reception of the DCF77 time signal ​
(CET and CEST time). The DCF77 time signal is sent from a German central transmission ​
point in Frankfurt/Main and Mainflingen and can be received at a distance of up to approx. ​
2,000 km.
By connecting the Kit DCF77 to the fire alarm system IQ8Control, the system time will be ​
automatically set to this time signal. This applies to stand-alone fire alarm control panel.
Each fire alarm control panel (FACP) or essernet network must only be connected to a single ​
DCF77 time master.
784892
Printer kit with paper take-up reel for IQ8Control C/M
1
40 characters, printer with fixed print head.
When the printer is installed in the FACP IQ8Control C, the battery case, including toroidal t​ransformer, must be replaced by the mounting rack. The batteries and the toroidal transformer ​must
be installed in an additional extension housing, either 789300 or 789301.
Mounting frame complete with Part No. 736234 plain text thermal printer including winder and ​
end-of-paper recognition.
Available until Q4/2013
Accessories
736235 Printer paper for printer 736233 / 736234 / 784892
736235
Printer paper for printer 736233/736234/784892
1
Printer paper for part no. 736233 printer without paper take-up reel and for part no. ​
736234 printer with take-up reel.
Technical Data
Dimensions
736264
L: 2500 mm W: 58 mm
Printer paper for printer 736259
1
For printers (part no. 736259) with paper take-up reel.
Technical Data
Dimensions
772445
L: 2500 mm W: 60 mm
Mounting frame 19" IQ8Control C/M
1
Mounting frame with 6 HU for mounting of operating front and printer.
22
www.hls-austria.com
Control Panels
IQ8Control
1
Accessories for System 8000 and IQ8
743212
2
Spare key 1D009 for FACP
1
For upright cabinets 769163 and 769164.
3
Two keys.
4
5
743245
Lever lock - type 17 for key no. 801
1
To lock and unlock the HMI of fire alarm panels 2001, IQ8Control C/M, 8000 M/C, 8007, ​
8008.
6
Two keys and one cylinder lock.
7
8
769914
Spare key 801 for FACP
9
1
To lock and unlock the HMI of fire alarm panels 2001, IQ8Control C/M, 8000 M/C, 8007, ​
8008.
10
Two keys.
11
743248
12
Lever lock - type for key no. 901
1
To lock and unlock the housing frame of fire alarm panels IQ8Control C/M, 8000 M/C and ​
FlexES.
13
Two keys and one cylinder lock.
14
15
769915
Spare key 901 for FACP
1
For fire alarm panels 2001, IQ8Control C/M, 8000 C/M, 8008 for printer and housing.
Two keys.
23
Control Panels
744030
IQ8Control
Dummy cover 19", 2 HU
1
For covering free installation space in upright cabinets and wall cabinets, 2 HU.
Technical Data
Material
Color
sheet steel
gray similar to Pantone 538
One height unit (HU) covers 44.45 mm.
744027
Dummy cover 19", 3 HU
1
As 744030, but 3 HU.
Technical Data
Color
744028
Dummy cover 19", 5 HU
1
As 744030, but 5 HU.
744029
Dummy cover 19", 9 HU
1
As 744030, but 9 HU.
24
www.hls-austria.com
gray similar to Pantone 538
Control Panels
IQ8Control
1
Maintenance and Test Equipment
789861
tools 8000 programming software
2
Convenient Windows programming software CD for programming the fire alarm panels ​
belonging to Series 8000 C/M, 8008, IQ8Control, FlexES control, Gateway and extended ​
supplementary text in ¼ VGA display.
3
For programming, the 789862.10 field bus interface is required.
4
System requirements:
- FACP 8000 C/M, FACP 8008 or IQ8Control C/M as of software version V2.20
- PC/Notebook as of Windows XP, Vista and Windows 7 but no Windows NT (no USB support)
- Recommended configuration: 512 MB RAM, 500 MHz CPU
5
This software is also to be used for the LCD panels 785101 and 785103.
789860.10
6
tools 8000 PLus equipment starter kit
1
Complete package for programming of the fire alarm control panels 8007, 8000C/M, 8008, ​
Gateway, ABIGA and IQ8Control via PC or Notebook.
7
The field bus interface is used as a programming interface between the FACP and the PC/​notebook.
Furthermore, the field bus interface facilitates the direct connection of a ring bus to the c​ onvenient monitoring of a finished installation and the elimination of possible cabling mistakes.
789861
789862.10
789863
789864
8
Programming software for System 8000 and IQ8Control
Field bus and control panel interface PLus
USB cable
Serial connecting cable
9
Accessories
BME2Z002 Switched-mode power supply with cylindrical plug
789866
USB programming cable for extinguishing panel 8010
10
11
Control panel
USB
12
13
Field bus interface
14
esserbus-PLus
Loop length max. 3,5 km
esserbus-transponder
15
Application example
25
Control Panels
789862.10
IQ8Control
Field bus interface PLus
1
Interface for the programming of the fire alarm control panels 8007, 8000C/M, 8008, ​
gateway, ABIGA and IQ8Control or for the direct field-side connection of a single installed ​
analog loop. With the optional switched-mode power supply BME2Z002, bus-supplied ​
alarm signaling equipment can be tested independently from the control panel via the ​
direct connection to the field bus interface 789862.10. (V1.12 or above of programming ​
software tools 8000 is required)
Technical Data
Ambient temperature
Storage temperature
Type of protection
Housing
Color
Weight
Dimensions
5 °C ... 45 °C
0 °C ... 50 °C
IP40
plastic, PS (Polystyrene)
white, similar to RAL 9010 / gray, similar to RAL 7035
approx. 300 g
W: 68 mm H: 30 mm D: 135 mm
Connecting cables 789863 and 789864 are not included in delivery.
Windows NT does not support any USB interface. Therefore the use of the programming ​software tools 8000 is possible under Windows NT only with the usage of programming ​interface
RS 232 (part no. 769828).
One interface and two 6-pin plugs.
Accessories
BME2Z002 Switched-mode power supply with cylindrical plug
USB
Power supply for bus supplied
alarm signaling devices
Field bus interface
EFI-Plus
esserbus-PLus
Loop length max. 3,5 km
esserbus-transponder
Application example
789863
USB cable A/B for 789862 field bus & panel interface
1
For connecting service PC / laptop with the tools 8000 field bus and panel interface.
Technical Data
Cable length
26
www.hls-austria.com
1.8 m
Control Panels
789864
IQ8Control
1
Serial connecting cable for 789862
1
For connecting the field bus interface to panels 8007, 8000C/M, 8008, Gateway, ABIGA and ​
IQ8Control. With 4-pin special plug for the control panel.
2
Technical Data
Cable length
1.9 m
3
4
BME2Z002
Switched-mode power supply with cylindrical plug
1
Technical Data
Output voltage
Output current
5
12 V DC
1A
6
7
769828
Control panel interface RS 232
8
1
Interface for programming all Series 8000 fire alarm control panels, extinguishing panel ​
8010 and 5008 intrusion detection control panels with a notebook and programming soft­
ware.
9
- IDT 770597 programming software and 381137 maintenance software
- FDT tools 8000 programming software (789861)
- LKDE programming software for extinguishing panel 8010 / series 3 and 4
10
Technical Data
Dimensions
W: 65 mm H: 125 mm D: 30 mm
11
9-pin PC serial interface required!
Interface cable 756649
789866
12
USB programming cable for extinguishing panel 8010
1
13
Connecting lead for programming the extinguishing control panel 8010.
Fieldbus interface
14
USB
Connecting cable, Part-No. 789866
15
esserbus
Extinguishing panel 8010
27
Control Panels
Extinguishing System
Extinguishing System 8010 - Wall Mounting
1
Approval: VdS
Features
Addressable control device with integrated fire detection module for an extinguishing area ​
in accordance with VdS 2496 and EN 12094-1. The extinguishing panel 8010 is an elec­
tronic control device for extinguishing systems with integrated fire detection module, ​
compatible with Series 9200 and IQ8Quad detectors. It is additionally provided with ​
respective detection zones for manual alarm, post flooding and emergency stop as well as ​
two zones for extinguishing system fault. Complex control functions can be realised by ​
using the 13 control groups (relays). Up to 8 extinguishing areas on the esserbus of the ​
fire detection system communication transponders (optional). Respectively max. 16 ​
communication transponders per FACP 8000 C/M or IQ8Control 8000 or IQ8Control can be ​
networked via the 808615
• 1 Extinguishing area for max. 1.600 m² acc. to ​
Technical Data
•
•
•
•
•
•
•
•
•
•
•
•
VdS
8 detector zones for up to 30 Series 9200 and ​
IQ8Quad automatic detectors each (for two-​
detector dependency up to 25 detectors)
1 zone for manual alarm
1 zone for emergency stop
1 zone for post flooding
1 zone for extinguishing system fault
1 zone for blocking extinguishing system
1 control input for buzzer OFF
1 control input for control panel reset
8 relays, monitored or floating 30V DC/2A
3 relays, floating 30V DC/2A
2 mains voltage relays, floating 230V AC/2A
All outputs are provided with fuses
Rated voltage
Rated frequency
Quiescent current
Rated current
Battery capacity
Ambient temperature
Storage temperature
Type of protection
Housing
Color
Weight
Dimensions
CE certificate
230 V AC
50 ... 60 Hz
approx. 100 mA
0.7 A
2 x 12 V/24 Ah
-5 °C ... 45 °C
-10 °C ... 50 °C
IP 30
sheet steel approx. 1.25 mm
gray (similar to RAL 7035), blue (similar toRAL 5003)
approx. 18.3 kg (without battery)
W: 488 mm H: 625 mm D: 210 mm
0786-CPD-20223
The free programming software can be downloaded from our website (downloads section).
Accessories
Indicating and operating unit 788400 (stand alone operation mode required), 788615 esserbus ​
communication transponder, control zone indicator and 788016 alarm counter.
esserbus
Loop length max. 3.5 km
Extinguishing
panel 8010
IQ8Control
Monitoring
Module
Extinguishing Agent
Tank
Valve
Selector
Valve
Application example
788012.40
Extinguishing panel 8010 series 4 w/o operating unit
788013.40
Extinguishing panel 8010 series 4 with operating unit, German
As 788012.40 but with operating unit Part. No. 788400.
Technical Data
Weight
28
www.hls-austria.com
approx. 18.3 kg
Control Panels
Extinguishing System
1
Extinguishing Control Panel 8010 - Rack Mounting, 3HU
Features
• 8 detector zones for up to 30 Series 9200 or ​
IQ8Quad automatic fire detectors per detector ​
zone (max. 25 detectors in two-detector depend­
ency)
• 1 detector zone manual alarm
• 1 detector zone emergency stop
• 1 detector zone post flooding
• 1 detector zone blocked extinguishing system
• 1 control input buzzer off
• 1 control input reset control panel
• 8 monitorable relays 30V DC /2A
• 3 floating relays 30V DC /2A
• 2 relays for mains voltage 230V (connection at the​
back)
• Each output is protected by fuses
• Electronically controlled exhauster control
Operating unit:
• 13 LED-indication with inscription fields for indic­
ating activated outputs
• Mechanical alarm counter
• LED display to indicate the detector zone status
• LED collective display
• Keypad can be intuitively handled
• Key operated switch for keypad activation
• Emergency current supply 2 batteries 12V/12Ah ​
(not supplied as standard)
Addressable extinguishing panel as per EN 12094-1 for extinguishing zone control in ​
compliance with VdS 2496, with integrated fire detection unit and optional convenient ​
operating and indicating panel.
The slide-in concept enables space-saving, ergonomic integration into a 19-inch housing ​
for installation heights of only 3 height units (13.34 cm). Peripherals are connected at the ​
back of the housing via plug-in cable connections to accessible connection terminals, ​
allowing convenient installation within the housing before the insert is integrated. With the ​
communication transponder (part no. 808615), a maximum of eight extinguishing control ​
panels can be networked on one esserbus or powered loop in fire alarm systems FACP ​
8000 or IQ8Control. Via the programming interface plugged to the front, the extinguishing ​
panel settings can be adjusted to the specific requirements and information can be trans­
ferred for visualizing to the master fire alarm system via the loop.
2
3
4
5
Technical Data
Rated voltage
Rated frequency
Quiescent current
Rated current
Battery capacity
Ambient temperature
Storage temperature
Type of protection
Housing
Dimensions
CE certificate
230 V AC
50 ... 60 Hz
approx. 100 mA
0.7 A
2 x 12 V DC/12 Ah
-5 °C ... 45 °C
-10 °C ... 50 °C
IP 30
sheet steel
W: 483 mm H: 132 mm D: 403 mm (without grip)
0786-CPD-20223
6
7
8
The use of heavy duty rails from the respective cabinet manufacturer is recommended for i​nstallation in 19-inch upright cabinets.
9
Special
Connection module
incl. connection cable
(Part No. 788653
or 788654)
10
11
Fire alarm and
extinguishing
panel
No.1 to No.5
12
13
14
15
Power supply 230 V
Installation of multiple extinguishing panels in one upright cabinet
788014.40
Extinguishing control panel 8010 Series 4 with operating unit, ​German
1
Approval: VdS
Accessories
788653 Terminal card for panel 8010 in 19-inch technology (3 HU), 1 m
788654 Terminal card for panel 8010 in 19-inch technology (3 UH), 2 m
29
Control Panels
788014.40.GB
Extinguishing System
Extinguishing control panel 8010 Series 4 with operating unit, ​English
1
Approval: VdS
As 788014, but English version.
Accessories
788653 Terminal card for panel 8010 in 19-inch technology (3 HU), 1 m
788654 Terminal card for panel 8010 in 19-inch technology (3 UH), 2 m
788014.40.PL
Extinguishing control panel 8010 Series 4 with operating unit, ​Polish
As 788014, but Polish version.
788014.40.RU
Extinguishing control panel 8010 Series 4 with operating unit, ​Russian
As 788014, but Russian version.
788014.40.CZ
Extinguishing control panel 8010 Series 4 with operating unit, ​Czech
As 788014, but Czech version.
788014.40.SK
Extinguishing control panel 8010 Series 4 with operating unit, ​Slovakian
As 788014, but Slovak version.
788014.40.RO
Extinguishing control panel 8010 Series 4 with operating unit, ​Romanian
As 788014, but Romanian version.
788015.40
Extinguishing control panel 8010 Series 4 w/o operating unit
1
Approval: VdS
Accessories
788653 Terminal card for panel 8010 in 19-inch technology (3 HU), 1 m
788654 Terminal card for panel 8010 in 19-inch technology (3 UH), 2 m
Accessories
788653
Terminal card for panel 8010, 1 m
1
Length of plug-in connection cables: 1 m
2 x 50-pin connection cable 1m D-Sub50
1 x terminal card for top hat rail or C-rail mounting with D-Sub pin connectors
1 x terminal card for top hat rail or C-rail mounting with D-Sub multipoint connectors
788654
Terminal card for panel 8010, 2 m
1
As 788653 but plug-in connection cable with 2 m length.
30
www.hls-austria.com
Control Panels
Extinguishing System
Options for Extinguishing Control Panel 8010
1
788400
2
Indicating and operating panel for ECP 8010, German
1
Integrated detector zone indication in German. Can be set to status indication for control ​
outputs. LED for relevant extinguishing system function indication.
3
4
5
788401
Indicating and operating panel for ECP 8010, English
1
As 788400, but English.
6
7
8
788402
Indicating and operating panel for ECP 8010, Polish
9
As 788400, but Polish.
788404
Indicating and operating panel for ECP 8010, Czech
10
As 788400 but Czech.
788406
Indicating and operating panel for ECP 8010, Romanian
11
As 788400 but Romanian.
788016
12
Panel 8010-option with control group indicator and alarm counter, ​German
1
Additional LEDs for indicating activated control outputs and mechanical alarm counter. The ​
indicators are mounted to the second recess of the 8010 releasing control equipment. The ​
PCB connection cable is connected to the 788400 indicating and operating panel.
13
Foil with German description
14
15
788023.10
Multiple-sector interface in housing
1
Approval: VdS
For the formation of multiple-sector control, up to four extinguishing panels 8010 can be ​
networked via a multiple-sector interfaces. The cascading of a max. of 3 multiple-sector ​
interface is possible for multi-sector control of a max. of 10 extinguishing panels 8010.
31
Notes
32
www.hls-austria.com
1
2
3
4
5
6
7
8
9
10
Power Supply
Power Supply Units
34-35
Voltage Converters
36
Batteries (rechargeable)
37
Accessories
38
11
12
13
14
15
33
Power Supply
Power Supply Units
Power Supply - Housing Version
1
Approval: VdS, CNBOP
The power supply ZSP135-DR is dedicated to work in fire detection and building automa­
tion systems. It is a source of guaranteed 24V voltage. It is manufactured as a wall box ​
with a lock. It has a space inside to mount two batteries. The controller protects the ​
internal battery bank against too low discharge by means of the built-in disconnect device. ​
The power supply complies with the norm EN 54 and EN 12101-10.
Features
• light indication of the state of the power supply
• floating mode with temperature compensation
• equalize charging of the battery with the charging ​
current limitation
• detection of low and high voltage of the battery
• detection of a battery circuit break
• electronic low voltage disconnect of the battery
• monitoring of output fuses
• continuous testing of the rectifier’s operation
• monitoring of the internal temperature
• visual and remote indication of alarm
960000.10.GB
Application:- components of fire alarm systems
- actuators of smoke extraction systems and fire and smoke dampers
- fire alarm control panels
- devices of industrial automation
Technical Data
Rated voltage
Output voltage
Efficiency
Cooling
Ambient temperature
Type of protection
230 V AC
24 V DC
> 80 %
Convection
-25 °C ... 55 °C
IP43
External power supply 2 A / 24 V DC 17Ah EN 54-4
Batteries for power supplies ZSP135-DR should be ordered separately.
Technical Data
Output current
Rated Output Current
Battery capacity
Weight
Dimensions
960001.10.GB
max.2 A
1 A
max. 17 Ah
approx. 18 kg (incl. batteries)
W: 390 mm H: 350 mm D: 90 mm
External power supply 3 A / 24 V DC 17Ah EN54-4
Batteries for power supplies ZSP135-DR should be ordered separately.
Technical Data
Output current
Rated Output Current
Battery capacity
Weight
Dimensions
960002.10.GB
max.3 A
2 A
max. 17 Ah
approx. 18 kg (incl. batteries)
W: 390 mm H: 350 mm D: 90 mm
External power supply 3 A / 24 V DC 28Ah EN 54-4
Batteries for power supplies ZSP135-DR should be ordered separately.
Technical Data
Output current
Rated Output Current
Battery capacity
Weight
Dimensions
34
www.hls-austria.com
max.3 A
1.5 A
max. 28 Ah
approx. 28.3 kg (incl. batteries)
W: 390 mm H: 350 mm D: 140 mm
Power Supply
960003.10.GB
Power Supply Units
1
External power supply 5 A / 24 V DC 17Ah EN 54-4
Batteries for power supplies ZSP135-DR should be ordered separately.
2
Technical Data
Output current
Rated Output Current
Battery capacity
Weight
Dimensions
960004.10.GB
max.5 A
4 A
max. 17 Ah
approx. 18 kg (incl. batteries)
W: 390 mm H: 350 mm D: 90 mm
3
4
External power supply 5 A / 24 V DC 28Ah EN 54-4
Batteries for power supplies ZSP135-DR should be ordered separately.
5
Technical Data
Output current
Rated Output Current
Battery capacity
Weight
Dimensions
960005.10.GB
max.5 A
3.5 A
max. 28 Ah
approx. 28.3 kg (incl. batteries)
W: 390 mm H: 350 mm D: 140 mm
6
7
External power supply 5 A / 24 V DC 40Ah EN 54-4
Batteries for power supplies ZSP135-DR should be ordered separately.
8
Technical Data
Output current
Rated Output Current
Battery capacity
Weight
Dimensions
960006.10.GB
max.5 A
3 A
max. 40 Ah
approx. 42.3 kg (incl. batteries)
W: 450 mm H: 350 mm D: 180 mm
9
External power supply 7 A / 24 V DC 28Ah EN 54-4
10
Batteries for power supplies ZSP135-DR should be ordered separately.
Technical Data
Output current
Rated Output Current
Battery capacity
Weight
Dimensions
960007.10.GB
11
max.7 A
5.5 A
max. 28 Ah
approx. 28.3 kg (incl. batteries)
W: 390 mm H: 350 mm D: 140 mm
12
External power supply 7 A / 24 V DC 40Ah EN 54-4
13
Batteries for power supplies ZSP135-DR should be ordered separately.
Technical Data
Output current
Rated Output Current
Battery capacity
Weight
Dimensions
14
max.7 A
5 A
max. 40 Ah
approx. 42.3 kg (incl. batteries)
W: 450 mm H: 350 mm D: 180 mm
15
35
Power Supply
781335
Voltage Converters
DC / DC converter 12 V / 24 V DC
1
Approval: VdS
This converter generates 24 V as power supply for special detectors. The input voltage of ​
12 V is taken from the fire alarm control panel or an external 12 V power supply. Mounted ​
inside the FACP (mounting kit 788605), this module can supply up to 4 special detectors ​
with a maximum current of 125 mA each or 1 special detector with 500 mA. This module ​
can be integrated in cabinets 120240, 788600 and 788601. Please pay attention to the ​
primary current consumption (12 V) in case of mains failure.
Technical Data
Features
• Each output is separately fused
781336
Operating voltage
Output voltage
Output current
Ambient temperature
Storage temperature
Type of protection
Weight
Dimensions
9 ... 15 V DC
24 V DC ± 10 %
max. 500 mA (4 x 125 mA)
-10 °C ... 50 °C
-15 °C ... 55 °C
IP 40 (housing)
approx. 150 g
W: 65 mm H: 72 mm D: 20 mm
DC / DC converter output voltage
1
Approval: VdS
This converter generates 12 V as "electrically isolated" power supply for one special ​
detector. The input voltage of 12 V is taken from the fire alarm control panel or an external ​
power supply. This module can be integrated in cabinets 120240, 788600, 788601, and ​
788603. Please pay attention to the primary current consumption (12 V) in case of mains ​
failure.
Technical Data
Features
• Direct current potentials are electrically isolated
• Voltage interface, for instance, for operating ​
transponders connected to an extinguishing ​
control panel 8010 Series 3 configured for 12 V ​
DC operation
• Suitable for max 1.5 mm² connection terminals
• Short circuit resilient
781337
Operating voltage
Output voltage
Output current
Ambient temperature
Storage temperature
Type of protection
Weight
Dimensions
10 ... 28 V DC
12 V DC ± 10 %
max. 800 mA
-10 °C ... 50 °C
-15 °C ... 55 °C
IP 40 (housing)
approx. 70 g
W: 65 mm H: 72 mm D: 20 mm
The module can also be used in explosion endangered zones for the galvanic separation of the
esserbus ​voltage supply.
DC / DC converter output voltage 24 V DC
1
Approval: VdS
This converter generates 24 V as power supply for one special detector. The input voltage ​
of 12 V is taken from the fire alarm control panel or an external power supply. This module ​
can be integrated in cabinets 120240, 788600, 788601, and 788603. Please pay attention ​
to the primary current consumption (12 V) in case of mains failure.
Technical Data
Features
• Direct current potentials are electrically isolated
• Suitable for max 1.5 mm² connection terminals
• Short circuit resilient
36
www.hls-austria.com
Operating voltage
Output voltage
Output current
Ambient temperature
Storage temperature
Type of protection
Weight
Dimensions
10 ... 28 V DC
24 V DC ± 10 %
max. 400 mA
-10 °C ... 50 °C
-15 °C ... 55 °C
IP 40 (housing)
approx. 70 g
W: 65 mm H: 72 mm D: 20 mm
Power Supply
Batteries (rechargeable)
1
The listed lead storage accumulators are maintenance-free, sealed electrolyte batteries. ​
They are relatively position-independent (should not be charged upside-down), deep-​
cycled, cycle-resistant and long-lasting (4 to 5 years). Charge voltage at an ambient ​temperature of +20°C: 12 V DC (6 x 2.3 V per cell) 13.8 volts, this can be subject to toler­ances.
2
Technical data sheets are available on demand.
3
The batteries comply with the VDE 0833-1 regulations for hazard alarm systems and are VdS ​
approved.
018001
Battery 12 V DC / 1.2 Ah capacity
4
018002
Battery 12 V DC / 2.1 Ah capacity
5
018004
Battery 12 V DC / 7 Ah capacity
6
018011
Battery 12 V DC / 12 Ah capacity
7
2 x Fast-On Adapters from 6.3 mm to 4.3 mm
8
018006
Battery 12 V DC / 26 Ah capacity
9
2 x Fast-On Adapters from M6 to 6.3 mm each 2 x M5 hexagon head cap screws, washers and ​
snap rings.
018007
10
Battery 12 V DC / 17 Ah capacity
2 x Fast-On Adapters from M6 to 6.3mm each 2 x M5 hexagon head cap screws, washers and ​
snap rings.
018009
11
Battery 12 V DC / 38 Ah capacity
12
2 x Fast-On Adapters from M6 to 6.3mm each 2 x M6 hexagon head cap screws, 4 x washers ​
and snap rings.
13
018010
Battery 12V DC / 65Ah capacity
2 x Fast-On Adapters from M6 to 6.3mm each 2 x M6 hexagon head cap screws, 4 x washers ​
and snap rings.
14
15
37
Power Supply
785753
Accessories
Accumulator / battery kit
1
Terminals for the connection of batteries with a minimum capacity of 12 Ah.
018051
9 V Alkaline Manganese battery
1
805597
3.6V Lithium battery
1
4 Lithium batteries for use in wireless detector base (Part no. 805593.10), wireless ​
gateway for detectors (Part no. 805594.10) and wireless universal interface (Part no. ​
805601.10/805602.10).
4 pcs
38
www.hls-austria.com
1
2
3
4
5
6
7
8
9
10
Display and Operating Units
LED Indicator Panel
40
LCD Indicator Panel
41
System 3000
42-45
11
12
13
14
15
39
Display and Operating Units
764790
LED Indicator Panel
Standard LED remote indicator panel
1
Approval: VdS
Additional indicator for up to 32 alarm, trouble or collective signals. Connection via an ​integrated 32-pin terminal strip. The indicator is controlled via relay contacts or semicon­ductor
outputs with positive-guided contacts in the hazard detection system. With key for ​lamp
testing, integrated buzzer and easy-to-maintain terminal card. Elegant plastic ​housing for
surface mounting.
Technical Data
Operating voltage
Quiescent current @ 12 V DC
Alarm current @ 12 V DC
Display
Connection terminal
Ambient temperature
Storage temperature
Air humidity
Type of protection
Housing
Color
Weight
Dimensions
10 ... 15 V DC
approx. 1 mA
approx. 380 mA (incl. 32 LED & buzzer)
32 LED, red
max. 1.5mm²
-5 °C ... 50 °C
-25 °C ... 75 °C
≤ 95% (w/o condensation)
IP 40
ABS plastic
white (similar to RAL 9003), front blue (similar to RAL ​
5003)
approx. 1000 g
W: 270 mm H: 221 mm D: 71 mm
This indicator panel is not suitable for application as an initial warning device for the fire brigade.
804791
Loop LED remote indicator panel for 32 messages
1
Approval: VdS
As 764790 but with integrated and wired esserbus transponder 32 LED's for operation as a ​
remote indicating panel for the esserbus. For connection to the esserbus and powered loop ​
in fire alarm systems 8000 and IQ8Control.
Technical Data
Operating voltage
Quiescent current @ 12 V DC
Alarm current @ 12 V DC
Display
Connection terminal
Ambient temperature
Storage temperature
Air humidity
Type of protection
Housing
Color
Weight
Dimensions
10 ... 15 V DC
approx. 1 mA
approx. 380 mA (incl. 32 LED & buzzer)
32 LED, red
1.5 mm²
-5 °C ... 50 °C
-25 °C ... 75 °C
≤ 95% (w/o condensation)
IP 40
ABS plastic
white (similar to RAL 9003), front blue (similar to RAL ​
5003)
approx. 1000 g
W: 270 mm H: 221 mm D: 71 mm
Isolator (part no. 788612) not included, please order separately.
This indicator panel is not suitable for application as an initial warning device for the fire brigade.
40
www.hls-austria.com
Display and Operating Units
785101
LCD Indicator Panel
1
LCD indicator panel, English
1
Features
• Display of zone and detector status information of ​
the FACP with additional text
• Event memory for 200 messages
• Free programming up to a max. of 4,000 addi­
tional texts, each with 2 x 20 characters
• Sequential message interrogation via scroll keys
• Monitoring of the serial interface
• Internal buzzer, can be switched off via key
• Function test of the display elements
• ON-OFF operation
785107
The LCD indicator panel 785101 is used as an add-on device for the remote display of ​
FACP status information of the System 8000 IQ8Control relating to detectors and detector ​
zones.
Event messages are displayed via LED collective indicators and on the 2-line LCD display ​
with the associated detector zone number and a programmable additional text. Each ​
message is signaled via the built-in buzzer. The buzzer can be acknowledged by pressing a ​
button.
Up to 31 LCD indicator panels can be operated on an RS 485 bus, either directly on the RS ​
485 interface of the basic card of FACP 8007/8000C/8000M/IQ8Control or using a ​common
RS 485 converter (e.g. RS 232/RS 485 converter 764852) on another serial inter­face (e.g.
RS 232). In connection with panel 8008, only possible with RS 232/TTY micro­module
(784842) and RS 232/RS 485 converter (764852).
The additional texts are programmed using the tools 8000 software package and a service ​
PC connected via the 769862.10 programming interface.
2
3
4
5
Technical Data
Operating voltage
Quiescent current
Alarm current @ 12 V DC
Ambient temperature
Storage temperature
Type of protection
Housing
Color
Weight
Dimensions
8.5 ... 14 V DC
approx. 30 mA
approx. 60 mA
0 °C ... 45 °C
0 °C ... 50 °C
IP30
plastic (ABS)
white, similar RAL 9001
approx. 750 g
W: 206 mm H: 177 mm D: 48.5 mm
6
7
8
LCD indicator panel, Polish
As 785101, but Polish version.
785109
9
LCD indicator panel, Czech
10
As 785101, but Czech version.
785113
LCD indicator panel, Hungarian
11
As 785101, but Hungarian version.
785115
LCD indicator panel, Turkish
12
As 785101, but Turkish version.
13
14
15
41
Display and Operating Units
System 3000
Fire Brigade Operating Panels
784710
Fire brigade operating panel, German
1
Approval: VdS
The fire department operating unit (in accordance with DIN 14661) is an additional device ​
for fire detection systems that contains transmission units to the fire department. The ​
essential display and operating elements of the fire alarm control panel are located on the ​
fire department operating unit (FDOU). The fire department can handle all necessary alarm ​
measures via the FDOU – so they do not need any special introduction to the control panel.
Technical Data
Operating voltage
Quiescent current @ 12 V DC
Alarm current @ 12 V DC
Ambient temperature
Storage temperature
Type of protection
Housing
Color
Weight
Dimensions
10.5 ... 30 V DC
approx. 18 mA
approx. 75 mA
0 °C ... 50
-10 °C ... 60 °C
IP 30
sheet steel
gray, similar toRAL 7032
approx. 3.4 kg
W: 255 mm H: 185 mm D: 58 mm
This fire department operating unit is not compatible to any FlexES control!
The fire brigade operating panel is supplied without locking cylinder (DIN 18252). It should be ​
acquired in accordance with the guidelines provided by the regional fire brigade.
784710.PL
Fire brigade operating panel, Polish
As 784710 but Polish version.
LCD Indicator Panels
784743
Fire department indicating panel FAT3000
1
Approval: VdS
Microprocessor-controlled fire department indicating panel in compliance with DIN 14662 ​
as an additional indicator for fire alarm panels. Serial connection to the fire alarm panel via ​
variable interfaces TTY, DUAL RS 485, RS232 and ESPA 4.4.4 (on board), conventional a​ nd
redundant activation, plain text display with 4 x 20 characters, collective LED indication ​
(alarm, trouble, deactivation). Simple handling with 4 buttons (buzzer OFF/level/scroll ​
buttons). Additional text (> 4000 texts) can be programmed using a PC with serial interface ​
connection, event memory, redundancy via loop structure for up to 16 FAT, power supply ​
and signaling pathway are monitored to prevent short or open circuits, full functional range ​
during breakdown of one circuit. The ESPA interface enables direct connection of telecom­
munication and paging systems.
ser.- IF
UB
Technical Data
ESPA 4.4.4
RS 232
telecom device
or pager
FACP
Operating voltage
Quiescent current @ 12 V DC
Alarm current @ 12 V DC
Ambient temperature
Storage temperature
Type of protection
Housing
Color
Weight
Dimensions
8 ... 30 V DC
approx. 65 mA
approx. 125 mA
-5 °C ... 40 °C
-10 °C ... 60 °C
IP 30
sheet steel
gray, similar to RAL 7032
approx. 3.5 kg
W: 255 mm H: 185 mm D: 58 mm
The module can only be used when combined with a System 8000 or IQ8Control Fire Alarm ​
Control Panel.
Programming software "FatProgWin" is included.
784743.PL
Fire brigade operating panel, Polish
As 784743 but Polish version.
42
www.hls-austria.com
Display and Operating Units
System 3000
1
Plain Text Indicator and Operating Panels
2
784725.PL
1
Sheet steel housing with two leaves for surface mount or flush mount installation with ​
central leaf opening for both door leaves. The right-hand housing door can be individually ​
opened by means of a built-in CL1 lock. Door opening through fire brigade locking ​
(suitable for half profile cylinder installation). In the left-hand half of the housing, a 784743 ​
fire service indicator panel and a fire service operating panel 784710 are installed. The ​
housing is designed for receiving a transmission unit or a manual call point. The fire ​
service indicator panel is actuated via the serial interface in the control panel. The fire ​
service operating panel is connected to the control panel interface. A maximum of 2 x 100 ​
DIN A4 / horizonal layout fire brigade route maps can be integrated.
3
4
5
Technical Data
Operating voltage
Quiescent current @ 12 V DC
Alarm current @ 12 V DC
Ambient temperature
Storage temperature
Type of protection
Housing
Color
Weight
Dimensions
10 ... 30 V DC
approx. 50 mA
approx. 180 mA
-5 °C ... 40 °C
-10 °C ... 60 °C
IP30
sheet steel
red, similar to RAL 3000
approx. 15 kg
W: 710 mm H: 560 mm D: 100 mm
6
7
Only in combination with the System 8000, IQ8Control fire detection panels. For redundant ​
operation, redundancy module ADP-N3E (Part No. 784744) is required.
8
Double-leaf sheet steel housing
Fire service indicating panel 784743
Fire service operating panel 784710
9
10
11
12
13
14
15
43
Display and Operating Units
System 3000
Adapter
784744
Adapter module ADP-N3E
1
Microprocessor-controlled module for installation (mounting rail) in System 8000 or ​
IQ8Control fire alarm panels. In compliance with DIN 14675, the TTY interface can be used ​
for redundant transmission when the adaptor is connected and when the fire department ​
indicating panel FAT3000 is used for initially informing the fire department. Additional text ​
(> 4,000 texts) can be programmed using a PC with serial interface connection.
Technical Data
Features
• Input: TTY from the internal FACP interface
• Output: DUAL RS 485 to the FAT interface
Operating voltage
Quiescent current @ 12 V DC
Contact load relay
Connection terminal
Ambient temperature
Storage temperature
Weight
Dimensions
8 ... 30 V DC
approx. 55 mA
30 V DC / 1 A
max 2 x 0.8 mm²
-5 °C ... 40 °C
-10 °C ... 60 °C
approx. 100 g
W: 80 mm H: 150 mm D: 30 mm
The top hat rail module (part no. 788652) and the module housing for snap-on mounting rail ​
(part no. 788603.10) can be used for installation. The interface is compatible with FAT3000 ​
(784743). Power is supplied by the fire alarm panel or an external power supply unit. Maximum ​
data line length: 800 m.
784734
Adapter module ADP-N3S
1
Same as 784744 but for the integration of another fire detection system into an existing ​
redundant FAT 3000 bus in an ADP-N3E adaptor module. Unlike the ADP N3E, the ADP-​
N3S does not provide power supply for redundant operation.
Technical Data
Operating voltage
Quiescent current @ 12 V DC
Contact load relay
Connection terminal
Ambient temperature
Storage temperature
Weight
Dimensions
784753
8 ... 30 V DC
approx. 60 mA
30 V DC / 1 A
max 2 x 0.8 mm²
-5 °C ... 40 °C
-10 °C ... 60 °C
approx. 100 g
W: 80 mm H: 150 mm D: 30 mm
Adapter module ADP-PRS-422
1
Additional module for connecting a paging system to a Series 8000 / IQ8Control fire alarm ​
system with ADP-N3E. To connect the paging system via an electrically isolated RS232 ​
interface, an ADP-PRS-422 is used.
Technical Data
Operating voltage
Quiescent current @ 12 V DC
Dimensions
8 ... 30 V DC
approx. 5 mA
W: 100 mm H: 80 mm D: 20 mm
This adapter is not compatible to any FlexES control!
RS 422, max.
line length
1.000 m
FACP with adapter pcb
Part No. 784744
Connection example
44
www.hls-austria.com
RS 232, max.
line length
15 m
Adapter module ADP- PRS-422
Part No. 784753
Nurse call
system
Display and Operating Units
784754
System 3000
Adapter module ADP-PRS-232
1
The adapter module is an additional module suitable for electrically isolated connection of a​
paging system to a FAT 3000. The FAT 3000 programming interface (RS232 terminal) is ​
used for communication with the paging system. If an electrically isolated connection ​
between the FAT and the paging system is required, an ADP-PRS-232 must be used addi­
tionally.
2
1
3
Technical Data
Operating voltage
Quiescent current @ 12 V DC
Dimensions
8 ... 30 V DC
approx. 5 mA
W: 100 mm H: 80 mm D: 20 mm
4
The ADP PRS-422 module can also be used to connect a PC to the serial interface 784847.
RS 232, max.
line length
15 m
Fire department
indicating panel
FAT3000 Part No. 784743
RS 232, max.
line length
15 m
5
Nurse call
system
6
Adapter module
ADP- PRS-232
Part No. 784754
7
Connection example
8
9
10
11
12
13
14
15
45
Notes
46
www.hls-austria.com
1
2
3
4
5
6
7
8
9
10
Network Technology
essernet
48-52
Multiprotocol Gateway
53-56
11
12
13
14
15
47
Network Technology
essernet
The essernet is a short circuit and open circuit resistant 2-wire backbone for networking ​
fire detection and intrusion detection panels from the ESSER product range. The essernet ​
permits both hierarchy-restricted and hierarchy-free programming of panels. The essernet ​
has been tested and approved by the VdS. The hardware components are listed in the ​
respective equipment approvals of the fire detection panels.
Up to 31 panels can be networked with each other in a ring loop. Superior functions and ​
functions covering different panels can be programmed. The status of the entire system ​
can be read off on anything from one to all panels as desired. Likewise, the system can be ​
operated entirely from one panel.
Networking can be carried out via a simple telecommunication cable, e.g. IY-ST-Y 2 x 0.8 ​
mm, with 784840.10 or using a data cable, e.g. IBM type 1 as well as CAT5 cable, with ​
784841.10. With the essernet repeaters, cable distances of up to 3000 m between two
panels ​are possible. An optical waveguide fibre is possible with the converters, which are
listed ​below.
Third-party or management systems (e.g. WINMAGplus) can be connected via the serial ​
essernet interface.
3,5 km
Segment lenght max. 1 km
Application example
784840.10
essernet module, 62.5kBd
1
Network interface module for up to 16 network users (e.g. panels respectively SEI). ​
Protocol: similar to DIN 19245 - 1 (Profibus). Topology: loop structure, short circuit and ​
open circuit resistant.
Technical Data
Quiescent current @ 12 V DC
Cable
Cable length
784841.10
approx. 150 mA
telecommunications cable I Y (St) Y n x 2 x 0.8 mm
1000 m (max. between 2 users)
essernet module, 500kBd
1
Network interface module same as 784840.10 essernet loop module, but for a maximum
of ​31 network users (e.g. panels respectively SEI).
Technical Data
Quiescent current @ 12 V DC
Cable
Cable length
48
www.hls-austria.com
approx. 150 mA
IBM type 1,2,6 or similar (e.g. BELDEN 1634A)
1000 m (IBM Typ1 max. between 2 users), max. 400 m ​
when Cat3 cable or higher
Network Technology
784865
essernet
1
essernet repeater, 62.5kBd
1
Approval: VdS
2
The essernet repeater increases the maximum distance between two fire alarm control ​
panels in the essernet by up to 1000 m. Standard telephone cables can be used as connec­
tion leads. Two repeaters can be operated in line.
3
Technical Data
Operating voltage
Current consumption @ 12 V DC
Quiescent current @ 12 V DC
Ambient temperature
Storage temperature
Cable
Type of protection
Housing
Material
Color
Weight
Dimensions
784843
8 ... 18 V DC
approx. 100 mA
approx. 100 mA
-10 °C ... 70 °C
-20 °C ... 80 °C
telecommunications cable IY(St)Y n x 2 x 0.8 mm
IP 65
die-cast aluminum
die-cast aluminum
gray
approx. 520 g
W: 125 mm H: 60 mm D: 80 mm
4
5
6
essernet repeater, 500kBd
1
7
Approval: VdS
As 784865 but with 500kBd baud rate. IBM type 1, type 2 or type 6 cables can be used as ​
connection leads.
8
Technical Data
Operating voltage
Current consumption @ 12 V DC
Quiescent current @ 12 V DC
Ambient temperature
Storage temperature
Cable
Type of protection
Housing
Material
Color
Weight
Dimensions
8 ... 18 V DC
approx. 100 mA
approx. 100 mA
-10 °C ... 70 °C
-20 °C ... 80 °C
IBM-Typ 1, -Typ 2 or -Typ 6 or similar
IP65
die-cast aluminum
die-cast aluminum
gray
approx. 520 g
W: 125 mm H: 60 mm D: 80 mm
9
10
11
The respective 784841 essernet module must be ordered separately.
784763
12
Fiber optic converter for essernet, multimode, F-ST male
1
Fitted on locking device for C-rail mounting. Depending on the glass fiber used, distances ​
of up to 3 km are possible. Suitable for 50/125 µm and 62.5/125 µm multi-mode fibers.
13
Technical Data
Operating voltage
Current consumption @ 12 V DC
Application temperature
Storage temperature
FO-Connector
Type of protection
Weight
Features
9 ... 30 V DC
approx. 100 mA
-40 °C ... 85 °C
-55 °C ... 125 °C
F-ST
IP40
approx. 100 g
14
15
Prefabricated connecting cable included for connection to the essernet module in the FACP.
• Two multi-mode fibres are required per network ​
section.
• The fibres must be connected directly to each ​
other (not via a multiplexer).
• Fibre optics type G50 / 125 μm = max. attenuation ​
6 dB corresponding to a length of approx. 2000 m
• Fibre type G62.5 / 125 μm = max. attenuation 9 ​
dB corresponding to a length of approx. 3000 m.
• Up to 16 FOC connections per essernet network at ​
a transfer rate of 62.5 kBd.
• Up to 31 connections per essernet network at a ​
transfer rate of 500 kBd with LWL-converter from ​
Index “A“.
49
Network Technology
784764
essernet
Fiber optic converter for essernet, multimode, F-SMA male
1
As 784763, but with F-SMA male connection.
Technical Data
Operating voltage
Current consumption @ 12 V DC
Application temperature
Storage temperature
FO-Connector
Type of protection
Weight
9 ... 30 V DC
approx. 100 mA
-40 °C ... 85 °C
-55 °C ... 125 °C
F-SMA
IP40
approx. 100 g
Including prefabricated connection line for connection to the essernet module in the FACP.
784766
Fiber optic converter for essernet, single-mode
1
The fiber optic converter for essernet, required to connect two single-mode fibers, must be ​
installed directly into the control panel’s housing. This is done by mounting it directly to ​
the top-hat rail without any further mounting fixtures.
Technical Data
Features
• Two mono-mode fibres are required per network ​
section.
• The fibers must be connected directly without ​
•
•
•
•
•
•
interruption (e.g. no connection via multiplexers ​
permitted)
Fiber type G9/125 μm
max. permitted attenuation of 17 dB corresponds ​
to a length of approx. 20 km or
Fiber type G10/125 μm
max. permitted attenuation of 17 dB corresponds ​
to a length of approx. 20 km
Up to 16 optical fiber paths per essernet network
are possible with a transmission rate of 62.5 kBd
Up to 31 optical fiber paths per essernet network ​
are possible with a transmission rate of 500 kBd
784855
Operating voltage
Current consumption @ 12 V DC
Current consumption @ 24 V DC
Ambient temperature
Storage temperature
Wavelength
FO-Connector
Type of protection
Housing
Material
Mounting
Weight
Dimensions
9 ... 30 V DC
approx. 70 mA
approx. 35 mA
-5 °C ... 50 °C
-10 °C ... 55 °C
1300 nm
F-ST
IP40
aluminum
aluminum
mounting rail
approx. 200 g
W: 55 mm H: 24 mm D: 105 mm
Max. optical loss per FO-segment (20 km):
G9/125 µm: 17 dB, G10/125 µm: 17 dB
Accessories
788602 Top hat rail
788652 Mounting rail for FACP 8000 and IQ8Control
Serial essernet interface EDP, unidirectional
1
The serial essernet interface can be used as a gateway to link remote computers that ​
support the Esser data protocol (EDP). The EDP version (unidirectional) is only provided ​
with information from the essernet, remote control is not possible.The unit includes a slot ​
for an essernet module and is therefore a fully functional unit within the short circuit and ​
open circuit resistant essernet.
Technical Data
Features
• Serial data rate 19.2kBd
• RS 485 interface on-board for a max. length of ​
1,000 m
Operating voltage
Current consumption @ 12 V DC
Ambient temperature
Storage temperature
The essernet micromodule and the interface module are not included and must be ordered ​separately in accordance with the required essernet type and the serial transmission standard.
Accessories
788606
772386
772387
784840.10
784841.10
50
www.hls-austria.com
10.5 ... 28 V DC
approx. 60 mA
-5 °C ... 50 °C
-10 °C ... 50 °C
Housing kit
Interface-module RS 232/V24
Interface-module TTY/CL 20mA
essernet micromodule (62.5kBd)
essernet micromodule (500kBd)
Network Technology
784856
essernet
1
Serial essernet interface EDP, bidirectional
1
As 784855 but bidirectional with remote control options e.g. for the connection to a BMS ​
building management system.
2
Technical Data
Operating voltage
Current consumption @ 12 V DC
Ambient temperature
Storage temperature
10.5 ... 28 V DC
approx. 60 mA
-5 °C ... 50 °C
-10 °C ... 50 °C
3
The essernet micromodule and the interface module are not included and must be ordered ​separately, depending on the type of essernet and the serial transmission mode.
4
Accessories
788606
772386
772387
784840.10
784841.10
Housing kit
Interface-module RS 232/V24
Interface-module TTY/CL 20mA
essernet micromodule (62.5kBd)
essernet micromodule (500kBd)
5
6
784859
8000 FACP remote serial essernet interface
1
The serial essernet interface is a router with internal RS485 interface for interfacing an ​
8000, IQ8Control or FlexES fire alarm panel over relatively large distances e.g. subnetworks.
Features
• RS 485 interface on board for a max. length of ​
1,000 m
7
Information from the connected fire alarm panel is received via a router/router link and ​
made available in the host essernet. Whereat the first SEI is connected as Master and the ​
second SEI as Slave.
It has a slot for an essernet loop module and is thus an integral device in the short circuit ​
and open circuit resistant essernet. For remote function, you can use the integrated RS 485 ​
interface.
8
9
The essernet micromodule and the interface module are not included and must be ordered ​separately, depending on the type of essernet and the serial transmission mode.
10
770432 SEI setup
Accessories
788606
772386
772387
784840.10
784841.10
11
Housing kit
Interface-module RS 232/V24
Interface-module TTY/CL 20mA
essernet micromodule (62.5kBd)
essernet micromodule (500kBd)
12
13
14
15
51
Network Technology
essernet
Accessories
788606
Housing kit
1
Housing for the serial essernet interface.
Technical Data
Type of protection
Housing
Color
IP31
ABS plastic
white similar to RAL 9003, front blue similar to RAL ​
5003
W: 270 mm H: 221 mm D: 71 mm
Dimensions
772386
Interface module RS232/V24
1
For the serial essernet interface for a max. length of 15 m.
772387
Interface module TTY/CL 20mA
1
For the serial essernet interface for a max. length of 1,000 m.
013405.10
Hardware option TCP/IP converter, Ethernet RS232/RS485
1
This hardware option is used for the connection of an remote essernet via a (for example) ​
company-wide Ethernet LAN to a WINMAGplus control center via TCP/IP. Through this, the ​
device is used as a protocol converter between the SEI contained on the essernet and the ​
WINMAGplus control center available in the Ethernet LAN.
Technical Data
Features
• Transmission with RS232 max. length 15 m and ​
•
•
•
•
•
•
•
•
52
with RS485 max. length 1,000 m
Serial interface: RS232, RS422 or RS485 (2- and ​
4-wire), configurable via software
Transmission speed: 300 bauds to max. 230 ​
kBaud configurable via software
Serial connection: D-Sub 25, socket
Ethernet interface: 10Base-T/100Base-TX
Transmission speed: 10/100/auto Mbit, configur­
able via software
Mode of transmission: half- /full-duplex or auto­
matic, configurable via software
Network access: RJ45
Supported protocol: ARP, UDP, TCP, ICMP, ​
Telenet, TFTP, AutoIP, DHCP, HTTP, SNMP, TCP, ​
UDP and Telnet, TFTP
www.hls-austria.com
Operating voltage
Ambient temperature
Storage temperature
Type of protection
Housing
Weight
Power consumption
Dimensions
9 ... 30 V DC
0 °C ... 60 °C
-40 °C ... 85 °C
IP30
metal
approx. 200 g
1.5 W
W: 90 mm H: 64 mm D: 23 mm
System requirements for operation and software configuration: Windows® 2000 / XP.
Bidirectional or unidirectional data transfer depends on the SEI used, thus serial essernet i​nterface EDP unidirectional Part No. 784855 or bidirectional Part No. 784856. Up to 20 TCP/IP ​
converters can be connected per personal computer.
Management system
essernet
SEI
RS232
Ethernet
TCP/IP converter
RS485
Network Technology
1
Multiprotocol Gateway
1
Gateway for protocol conversion of the essernet data protocol into different standard software ​
protocols.
The multiprotocol gateways are a group of devices which have been specially optimized for ​
the conversion of the essernet data protocol to/into standard software protocols. The focus ​
here is especially the communication with higher-priority building services management ​
systems as well as with devices by other manufacturers. Device configuration is carried ​
out based on one text file per protocol driver as well as one other text file which sets the ​
connections between essernet object statuses to those of another protocol. This is advant­
ageous as it allows for easy revision with small changes, especially when the naming ​
conventions are adhered to in the target protocol. The basic configuration is created under ​
specification of the target protocol by conversion of project data export of the program­
ming software 'tools 8000' which results in a format that can be loaded by the gateway. ​
The gateway is equipped with an access-restricted web user-interface with independent ​
user management. This facilitates the upload of project data, remote diagnostics, status ​
query of all data points and if the corresponding ESSER modules are used switching via ​
the gateway without additional software. Hardware with different performance levels is ​
available for varying project requirements. Thus it is possible to choose the most cost-effi­
cient model according to the type of target protocol and number of connections required ​
from the essernet data protocol into the selected target protocol.
2
3
4
5
6
Service for installers:
7
We offer a number of gateway services. These services cover everything from calculating ​
data points to selecting suitable hardware, from creating loadable project planning for the ​
gateways to designing project-specific macros, as well as on site start-up. Gateway ​
support training is offered once the gateways are installed. This training includes mainten­
ance or expansion/reprogramming within the object, e.g. when a system has been ​
expanded and the new data points need to be transmitted into the target protocol.
The training and support is done by the development and supplier of the gateways. For part​
numbers and prizes please contact your sales representative.
8
9
Technical connection:
A serial essernet interface (SEI) (uni-directional or bi-directional) as well as an RS232/ V24 ​
interface module is needed for the connection of the multiprotocol gateways to the ​
essernet. If a FlexES FACP is used in the essernet it is possible to use the internal RS485 ​
interface for connection if the RS485/RS232 interface converter is also applied. Switching ​
functions such as turning individual detectors or whole detector zones on and off are ​
possible if the internal interface of the FlexES or a bi-directional SEI is used for the gateway ​
connection. In addition to the driver for the essernet protocol, delivery includes one of the ​
drivers listed on the order sheet at the end of the catalog in standard software protocols. ​
The multiprotocol gateway is designed for 230 V.
10
11
12
Different gateway models currently available:
13
ESSER Data Protocol (EDP) to:
BACnet Client or Server
OPC Server
MODBUS IP
EIB/Instabus
LONTalk
PROFIBUS-DP
14
15
53
Network Technology
Multiprotocol Gateway
If a gateway is used for the EDP connection over an OPC server, the OPC-DCOM communication ​
for the server component requires a networked PC with Windows XP or higher. This OPC server ​
component is included in this gateway model.
Additional hardware for the connection of the standard software protocol, as specified in the ​
order, is included in the delivery of the respective gateway variant.
For ordering the multiprotocol gateway, please refer to the order form at the end of the catalog.
Accessories
784855
784856
772386
788606
Serial essernet interface EDP (unidirectional)
Serial essernet interface EDP (bidirectional)
Interface module RS232/V24
Housing kit
Gateway
Modbus IP
Building Management
System
Modbus
Network
RS435 / RS232 converter
Serial essernet
interface
Communication
Transponder
Extinguishing
Control Panel
Serial Connection
Ethernet
Application example
54
www.hls-austria.com
essernet
esserbus
Network Technology
Multiprotocol Gateway
1
MPG DP500
1
The Multiprotocol Gateway DP500 is suitable for usage in small objects in which only a ​
small number of detection points must be transmitted. The maximum number of detection ​
points is 330 indicating and 200 indicating and switching. Here, a fire detector is valid as a ​
detection point. Because of its small dimensions and the integrated mounting rail supports,​
this device can be easily mounted into existing housing.
2
3
Technical Data
Features
Interfaces:
• 1 x RS485 BACnet MS/TP (B+, A-, AGND, screen)
• 1 x RS232 Rx, Tx, GND, RTS,CTS
• 1 x serial port RS232 9-pin fully allocated
• 1 x RJ45 10/100 Base-T
• 1 x USB
• CPU: ATMEL ARM9 200 MHz
• RAM 32 MB SDRAM
• Memory: 256MB Flash-RAM
• Operating system: Linux Real-time
Rated voltage
Rated frequency
Operating voltage
Output voltage
Power consumption
Output current
Ambient temperature
Mounting
Air humidity
Weight
Dimensions
100 - 240 V AC (power supply)
47 ... 63 Hz (power supply)
12 ... 26 V DC
24 V DC (power supply)
8W
2,5 A (power supply)
0 °C ... 50 °C
top hat rail mounting support
20% to 80% , non-condensing
approx. 400 g
approx. 0.6 kg (power supply)
W: 168 mm H: 33 mm D: 76 mm
W: 78 mm H: 93 mm D: 67 mm (power supply)
4
5
6
This device is not expandable via an internal card. One RS-485 interface is already integrated.
7
Multiprotocol Gateway, power supply, cross-over data cable, serial connection cable
8
• Power LED, green
• RxD LED, yellow
• TxD LED, yellow
• Status LED, multi-color
• Network media LED, orange
• Network activity LED, green
9
10
• 1 x digital input
• 1 x digital output (relay 1250W)
• Internal temperature sensor
• Network - bias resistors, 560 Ohm (DIP switches)
• Network – termination resistors 120 Ohm (DIP ​
11
switch)
12
MPG DP7500
1
The Multiprotocol Gateway DP7500 is suitable for usage in mid-sized objects. The ​
maximum number of detection points is 5000 indicating and 3000 indicating and ​switching. One fire detector counts here as a detection point. This device is ready for rear ​wall
mounting and can be integrated into existing upright cabinets.
Features
• Interface:
• 4 x RS232 9-pol (optional Com4 RS485 optoisol­
ated)
• 1 x RJ45 100/10 Base-T
• 1 x RJ45 1Gbit Base-T
• 4 x USB
• CPU: Pentium M 800MHz
• RAM: 512MB DDR-RAM
• Memory: 40GB HD, optional DiscOnChip
• Operating system: QNX
13
14
Technical Data
Rated voltage
Rated frequency
Operating voltage
Output voltage
Power consumption
Output current
Ambient temperature
Mounting
Air humidity
Weight
Dimensions
100 ... 240 V AC (power supply)
47 ... 63 Hz (power supply)
10 ... 30 V DC
24 V DC (power supply)
40 W
2,5 A (power supply)
5 °C ... 50 °C
back plane mounting
back plane mounting (power supply)
5% to 90%, non-condensing
approx. 3000 g
approx. 0.6 kg (power supply)
W: 292 mm H: 81 mm D: 145 mm
W: 78 mm H: 93 mm D: 67 mm (power supply)
15
Multiprotocol Gateway, power supply, cross-over data cable, serial connection cable
55
Network Technology
Multiprotocol Gateway
MPG DP35000
1
The Multiprotocol Gateway DP35000 is suitable for usage in large objects. The maximum ​
number of detection points is 23,000 indicating and 14,000 indicating and switching. One ​
fire detector counts here as a detection point. This device is constructed for upright ​cabinets with 19” slide-in unit and requires 4 rack units of free space for mounting.
Technical Data
Features
• Interfaces:
• 2 x RS232 9-pol
• 1 x RJ45 100/10 Base-T
• 4 x USB
• CPU: Intel PIII 1100MHz MMX™
• RAM: 256MB SDRAM
• Memory: 64MB non-volatile medium (Flash)
• Operating system: QNX
Rated voltage
Rated frequency
Power consumption
Display
Ambient temperature
Mounting
Air humidity
Weight
Dimensions
230 V AC
50 ... 60 Hz
300 W
Power LED and status LED
0 °C ... 45 °C
19" slide-in unit
20% to 80%, non-condensing
approx. 8000 g
W: 483 mm H: 178 mm D: 281 mm
Integrated power supply
Multiprotocol Gateway, cross-over data cable, serial connector cable
1
2
3
4
5
6
7
8
9
10
Management Systems
WINMAGplus
58-67
WINMAGLite
68
Difference WINMAGLite vs. WINMAGplus
69
11
12
13
14
15
57
Management Systems
1
WINMAGplus
Windows management system for hazard detection systems
• Modular construction and freely programmable
• Direct control of the network devices
• List of measures to be taken for fire-fighting ​
WINMAGplus has been specially developed to meet the requirements of managing and ​
integrating hazard detection systems on a single PC platform. WINMAGplus simultan­
eously manages and displays graphically a number of security applications, using a ​
common user interface including: fire detection technology; voice alarm public address; ​
intrusion detection technology; access control technology; video technology; rescue route ​
technology/escape door control, personnel protection systems and locating systems as ​
well as fence monitoring systems. Apart from security systems, a multitude of building ​
management control systems such as lighting, elevator control and fault detection ​
systems as well as door/gate/barrier control systems can be managed and graphically ​
displayed.
Database and user interface are designed in line with current standards: messages are ​
displayed both graphically and in text format. WINMAGplus offers various application ​
options, ranging from clearly displayed messages to active control of all detection devices. ​
Based on our security networks IGIS-Loop and essernet, WINMAGplus is not only a highly ​
professional system but also the best possible integrated visual data and management ​
solution.
• Individual allocation of usage rights incl. priority ​
Program:
Features
• Compatible with Windows XP Professional SP2, ​
Windows of 2003 servers and Windows Vista
forces
•
•
•
•
•
•
•
•
•
•
•
•
•
scheduling
Integrated simulation-functions
Extensive recording of events and operations
Visualization of messages
Up to 12 active graphics simultaneously repres­
entable
Integration of video sequences possible
Information output via Windows print manager to ​
multiple printers etc.
Time program/calendar function
Integrated database standard
Activation of other programs from WINMAGplus ​
possible
Efficient programming language (SIAS) for ​
customer-specific adjustment of interface and ​
processes in case of alarm
Remote control possible via modem (optional)
10 printers per workstation possible
Multiple monitors can be used. 4 of 8 screens ​
may be selected.
Thanks to its modular design, WINMAGplus offers suitable software for systems of any ​
size and type of application, ranging from WINMAGplus basic package for single-station ​
systems with one subsection being connected to the WINMAGplus multi-station system ​
with multiple subsections being connected. Licensing enables the program options ​
purchased and it legitimises program use. A dongle is acquired together with a license. The ​
dongle must be plugged into a parallel interface or into a USB port of the WINMAGplus ​
computer. With multi-station systems, every computer that is networked must be equipped ​
with a dongle. Workstations that are not networked do not need a dongle. The license is for ​
one version level (until version 7). If updating is effected to versions prior to V6.0 to V10.0 ​
and later versions, you automatically receive a dongle. If the dongle is removed during ​
operation, WINMAGplus runs for max. 72 hours in online mode.
Our services for installers:
Our WINMAGplus services include everything from entering alarm points to generating ​
diagrams. First of all, operators are made familiar with WINMAGplus. Then we work out t​he
specifications together with the customer and develop SIAS programs. We design ​
complete application packages and train your personnel. Until the final acceptance, we ​
offer support for all installation processes and assist you during daily operation via a ​
remote maintenance tool if required.
Interfaces, drivers:
Besides our security system drivers included in our product catalog, we offer a variety of ​
drivers for all kinds of trades and manufacturers. Due to the continuously rising number of ​
drivers, the current list of drivers can be requested when required. If the driver you need is ​
not available, we will develop a driver geared to your requirements. Alternatively, all instru­
ments can be connected via the standard OPC interface. This is an international standard, ​
which is supported by a multitude of manufacturers irrespective of their product lines. For ​
developing your own drivers, we can provide you with the connection server and a ​
developer’s package. Thus, individual WINMAGplus drivers can be created.
Hardware and software requirements:
Pentium 3 GHz or higher, minimum 512 MB RAM, minimum 1 GB of hard disk space, XGA ​
graphics card with minimum 4 MB video memory, monitor with min. 1024x768 pixels, sound ​
card with external speakers, Windows XP Professional SP 2, Windows 2003 Server, Vista and
Windows 7, Internet ​Explorer version 6.0 or higher.
To order WINMAGplus licenses, please use the order form found in the back of the catalog.
58
www.hls-austria.com
Management Systems
013610
WINMAGplus
1
Control center software CD WINMAGplus basic kit
WINMAGplus control center software CD for hazard detection systems, license not ​
included, compatible Windows XP Professional (SP3) 32-Bit version, Windows Server ​
2003 32-/64-Bit version, Windows Vista 32-/64-Bit version, Windows 7 32-/64-Bit version
and Windows Server 2008 32-/​64-Bit version. With the aid of this basic software and the
corresponding licenses, hazard ​detection systems can be operated and managed via PC.
Hazard reports are indicated in ​text form and graphically. In this way, the PC can also be
used as an electronic emergency ​control point. As of WINMAG version 10, this version can
be used as an upgrade (only for ​existing WINMAG versions 6 or older).
2
3
For demonstration purposes only, the WINMAGplus basic version operates without a license as ​a
full version for a total of twenty 8-hour days, after which the program switches to offline mode. ​
After expiry of the test time, all connections to all components are cut off. Starting in offline ​
mode does not reduce the number of test runs. The demo mode is a full-function editing ​environment. All components function except the online communication. Each process can also ​be
tested in demo mode through simulation and all editing functions can be used.
4
5
Please use order form printed in the appendix.
6
You can also download this software free of charge from our protected download area at
​www.hls.austria.com.
Basic Licenses
013631
7
Basic license for WINMAGplus USB port
8
This basic license is used to activate the basic software package/demo version to operate ​
as unrestricted visualizing software for server workstations and for network clients. For ​
interfacing control panels to server workstations, further licenses are required (see 013601 ​
– 013606, 013608, 013611, 013613, 013625).
9
Please use order form printed in the appendix.
10
Dongle for USB port
013630
Basic license for WINMAGplus parallel port
11
Basic licence for WINMAGplus control centre software including dongle for the parallel ​
port.
12
Basic license for WINMAGplus control center software including dongle for the parallel port.
This basic license is used to activate the basic software package/demo version to operate ​
as unrestricted visualizing software for server workstations and for network clients. For ​
interfacing control panels to server workstations, further licenses are required (see 013601 ​
– 013606, 013608, 013611-013613, 013625).
13
Please use order form printed in the appendix.
14
Dongle for parallel port
013633
15
Basic license for USB port 3-month duration
Dongle with USB port for licensing of the software. The data medium contains the license ​
information as well as the activation of the program options FDS, AC, FT and video.
The term is restricted to 3 months.
A one-time extension for a further 3 months is possible (part no. 013634).
Please use order form printed in the appendix.
Dongle for USB port and license disk
59
Management Systems
WINMAGplus
Upgrade Package
013634
Basic license extension for USB port
License file for extending the duration of 013633 an additional 3 months (only possible ​
once).
Please use order form printed in the appendix.
License disk
013616
WINMAG upgrade to WINMAGplus
Upgrade of a WINMAG installation from version 6 to the newest WINMAGplus control ​
center software.
For updating WINMAG V1 - 5 please use part no. 013617 in order form.
Please use order form printed in the appendix.
License file
013617
WINMAG installation upgrade as of version 6
WINMAG installation upgrade to the most recent WINMAGplus control centre software ​
version
WINMAG installation upgrade to the most recent WINMAGplus control center software version
An existing WINMAG as of version 6 can be upgraded to the most recent WINMAGplus ​
control center software version. For each installation with dongle (each connected PC) an ​
upgrade version must be separately ordered.
Please use order form printed in the appendix.
013645
WINMAG replacement dongle USB instead of parallel
Upgrade of basic software WINMAGplus. As a consequence of hardware exchange, the ​
parallel dongle needs to be replaced by a USB dongle.
Please use order form printed in the appendix.
Extension Licenses
013609
WINMAGplus control center software - subsequent upgrade
This order number serves as an auxiliary number for a subsequent optional extension or ​
(e.g. additional client or subsequent connection of video systems) to an existing WINMAG ​
installation from V 6.0. to V10 and WINMAGplus. The appropriate licenses must be o​ rdered
separately. The dongle need not be submitted.
Please use order form printed in the appendix.
013601
WINMAGplus license - intrusion detection technology
License option for WINMAG/WINMAGplus basic software. Required if intrusion detection ​
systems are connected to WINMAG.
This license may be ordered separately (subsequently) only in conjunction with the auxiliary ​
number 013609. The update number of the basic license must be included when ordering. The ​
license is used for connection of the Honeywell intrusion detection systems MB/HB, 5008 and
Galaxy..
Please use order form printed in the appendix.
60
www.hls-austria.com
Management Systems
013643
WINMAGplus
1
WINMAGplus license - Galaxy Dimension
License option for WINMAG/WINMAGplus basic software. Required if Honeywell Galaxy
Dimension intrusion detection ​technology is connected to WINMAG.
2
This license may be ordered separately (as subsequent optional upgrade) only in conjunction ​
with the auxiliary number 013609. The update number of the basic license must be included ​
when ordering. The license is used for connection of the Honeywell intrusion detection systems.
3
Please use order form printed in the appendix.
013626
WINMAGplus license - fire detection technology
4
License option for WINMAG/WINMAGplus basic software. Required if fire detection ​
systems are connected to WINMAG.
5
This license may be ordered separately (as subsequent optional upgrade) only in conjunction ​
with the auxiliary number 013609. The update number of the basic license must be included ​
when ordering. The license is used for connection of the Honeywell IQ8Control, system 8000 ​
1024, 1016 and FlexES Control fire detection systems.
6
Please use order form printed in the appendix.
013603
WINMAGplus license - access control
7
License option for WINMAG/WINMAGplus basic software. Required if access control ​
system devices are to be connected to WINMAG (e.g. ACS 2 and ACS 8). MultiAccess and/​
or IQ MultiAccess software package is also required.
8
This license may be ordered separately (as a subsequent optional update) only in conjunction ​
with the auxiliary number 013609. The update number of the basic license must be included ​
when ordering. The license is used for the connection of the Honeywell ACS and (IQ) ​MultiAccess access control systems.
9
Please use order form printed in the appendix.
013604
10
WINMAGplus license - video technology
License option for WINMAG/WiINMAGplus basic software. Required if video technology ​
equipment is to be operated via WINMAG. The crossbars can execute such commands as ​
pan, zoom, tilt, select monitor etc., depending on the model. The following video crossbars ​
are currently supported: Ernitec M 500 and M 1000; Honeywell MaxPRO 32; Philips LTC ​
8x00; Fusion series II / III; Geutebrück Vicrosoft; Geutebrück Multiscope; Honeywell ​
Fusion; HDPR series; contact your supplier for additional brands.
11
12
This license may be ordered separately (as a subsequent optional update) only in conjunction ​
with the auxiliary number 013609. The update number of the basic license must be included ​
when ordering.
13
Please use order form printed in the appendix.
14
013605
WINMAGplus license - rescue route technology/escape door ​control
License option for WINMAG/WINMAGplus basic software. Required if rescue route techno­
logy/escape door control equipment (only Honeywell Security) is to be operated via ​
WINMAG.
The status of escape doors is graphically displayed.
15
This license may be ordered separately (as a subsequent optional update) only in conjunction ​
with the auxiliary number 013609. The update number of the basic license must be included ​
when ordering. The license is used for connecting Honeywell rescue route technology/escape ​
door control equipment.
Please use order form printed in the appendix.
013623
WINMAGplus license - interfacing DEZ 9000
Option for connecting the DEZ 9000 remote control unit to the WINMAG/WINMAGplus ​
system. The connection also enables the installation of applications working on the basis ​
of VdS- 2465 transmission protocols to the WINMAG system.
Please use order form printed in the appendix.
61
Management Systems
013608
WINMAGplus
WINMAGplus license - RTD
License option for WINMAG/WINMAGplus basic license. Enables operation of WINMAG via ​
modem, using DS 7600 and DGA 2400 to ESSER IDT (HB and MB series) and fire detec­
tion systems (1024 series).
This license may be ordered separately (as a subsequent optional update) only in conjunction ​
with the auxiliary number 013609. The update number of the basic license must be included ​
when ordering.
Please use order form printed in the appendix.
013656
WINMAGplus license nurse call systems
Optional for WINMAGplus basic software. Required if it is to be connected to WINMAGplus ​
call system devices (e.g. Clino Phon 99) over the IPC control.
This license may be ordered separately (subsequently) only in conjunction with the auxiliary ​
number 013609. The update number of the basic license must be included when ordering. The ​
license is used for connection of the Honeywell intrusion detection systems MB/HB, 5008.
Please use order form printed in the appendix.
013619
WINMAG license HeiTel video connection
Licence option for WINMAG/WINMAGplus basic software. Required if HeiTel video systems​
are to be connected to WINMAG.
This license may be ordered separately (subsequently) only in conjunction with the auxiliary ​
number 013609. The update number of the basic license must be included when ordering. The ​
license is used for connection of the Honeywell intrusion detection systems MB/HB, 5008.
Please use order form printed in the appendix.
013620
WINMAG license MaxPRO VMS
License option for WINMAG/WINMAGplus basic software. Required if intrusion detection ​
systems are connected to WINMAG.
This license may be ordered separately (subsequently) only in conjunction with the auxiliary ​
number 013609. The update number of the basic license must be included when ordering. The ​
license is used for connection of the Honeywell intrusion detection systems MB/HB, 5008.
Please use order form printed in the appendix.
Connection Server
013606
WINMAGplus license connection server
License option for WINMAG/WINMAGplus basic software. Connection Server is a software ​
module that enables the connection of a 3rd party device to WINMAG. Connection Server ​
offers a convenient interface with which data and control commands can be exchanged bi-​
directionally in detection point format using WINMAG.
This license may be ordered separately (as a subsequent optional update) only in conjunction ​
with the auxiliary number 013609. The update number of the basic license must be included ​
when ordering.
Please use order form printed in the appendix.
013607
Connection server developers kit
This developers kit can be used to program WINMAG/WINMAGplus connections to third ​
party devices. The package contains the connection server developers kit including full ​
documentation plus a one-day training session in Albstadt (Germany).
Please use order form printed in the appendix.
Dongle for USB port and license file
62
www.hls-austria.com
Management Systems
WINMAGplus
1
OPC
013590
2
Universal gateway for PC (software)
Gateway software as a standalone solution for the allocation of data points on host control ​
center systems via OPC, ESPA 4.4.4.
3
Hardware and software requirements:
Pentium 3 GHz or higher, min. 512 MB RAM , min. 1 GB hard disk, XGA graphics card with min. ​
4 MB video memory, monitor with 1024 x 768 pixels or more, sound card with external ​speakers, Windows XP Professional SP2 and Windows 2003 Server, Windows Vista, Internet ​
Explorer 6.0 or higher.
4
Part No. 013590 may only be ordered in connection with Part No. 013618.
5
Please use order form printed in the appendix.
013618
Data points package
6
Package of 500 data points for project-related allocation of OPC tags, ESPA data points, ​
etc.
The data points package can only be ordered in connection with the license 013590 universal ​
gateway for PC and/or license 013611 OPC server.
7
Please use order form printed in the appendix.
013611
8
WINMAGplus license – OPC server
Option for WINMAG/WINMAGplus basic software. Required if WINMAGplus is to act as an ​
OPC server.
9
The OPC server license can only be ordered in conjunction with the 013618 license. This license ​
may be ordered separately (as a subsequent optional update) only in conjunction with the a​ uxiliary number 013609. The update number of the basic license must be included when ​ordering.
10
Please use order form printed in the appendix.
11
013612
WINMAGplus license – OPC client
Option for WINMAG/WINMAGplus basic license. This is required if WINMAG is to display ​
data from devices with OPC interfaces.
12
This license may be ordered separately (as a subsequent optional update) only in conjunction ​
with the auxiliary number 013609. The update number of the basic license must be included ​
when ordering.
13
Please use order form printed in the appendix.
14
15
63
Management Systems
WINMAGplus
Options
013613
Option - notification
License option for WINMAG/WINMAGplus basic license. Required if SMS (text message), ​
fax or e-mail are to be sent from WINMAG.
This license may be ordered separately (as a subsequent optional update) only in conjunction ​
with the auxiliary number 013609. The update number of the basic license must be included ​
when ordering. An ISDN connection (S0) as well as an ISDN card are required for the ​notification function.
Please use order form printed in the appendix.
013650
Option – escalation
Option for the WINMAG/WINMAGplus basic license. Required if short text messages ​
dispatched by WINMAG are to be acknowledged. Without acknowledgment, pre-​
programmed escalation plans can be activated.
This license may be ordered separately (as a subsequent optional update) only in conjunction ​
with the auxiliary number 013609. The update number of the basic license must be included ​
when ordering. For the escalation license, the 013613 notification license is required. A PC ​
sound card is required for this function.
Please use order form printed in the appendix.
013651
Option – DTMF control option
Option for the WINMAG/WINMAGplus basic license. Facilitates the execution of control ​
sequences via dual tone multi frequency (DTMF). With this, for example, it is possible to ​
switch system outputs connected to WINMAG on or off via mobile phone.
This license may be ordered separately (as a subsequent optional update) only in conjunction ​
with the auxiliary number 013609. The update number of the basic license must be included ​
when ordering.
Please use order form printed in the appendix.
013652
Option – ability for customized interface rights (client-side)
Option for the WINMAG/WINMAGplus basic license, allowing individual assignment of ​
interfaces and rights to several operators.
This license may be ordered separately (as a subsequent optional update) only in conjunction ​
with the auxiliary number 013609. The update number of the basic license must be included ​
when ordering.
Please use order form printed in the appendix.
013660
Option – WEBX
1
License option for the basic WINMAG/WINMAGplus license, allowing display of all system ​
statuses via Internet or Intranet, using standard browsers (max. 5).
This license may be ordered separately (as a subsequent optional update) only in conjunction ​
with the auxiliary number 013609. The update number of the basic license must be included ​
when ordering.
Please use order form printed in the appendix.
013624
Option – redundance
Option for redundant connection of essernet and IGIS-Loop security networks to the ​
WINMAG server. Interface operation for redundant networks is based on master/backup ​
operation and prevents data loss in WINMAG objects in case of disruption of network ​
connections caused by cable defects or COM port failure.
Please use order form printed in the appendix.
64
www.hls-austria.com
Management Systems
013625
WINMAGplus
Option – client
1
License option for WINMAG/WINMAGplus basic license. Enables operation of one client ​
station in a computer network with one server workstation. The license must be installed at ​
the server workstation. Clients require only the WINMAG software to be installed. One ​
WINMAG client license is needed per client.
2
1
This license may be ordered separately (as a subsequent optional update) only in conjunction ​
with the auxiliary number 013609. The update number of the basic license must be included ​
when ordering.
3
Please use order form printed in the appendix.
013640.10
4
WINMAGplus - remote-access package
With this remote-access package, WINMAG/WINMAGplus applications can be remotely ​
serviced and supported via modem. The package includes four hours of telephone support ​
within the first twelve months.
5
No modem is included with the package and must be provided in accordance with the existing ​
transmission technology.
6
Please use order form printed in the appendix.
013653
7
WINMAGplus – 4-monitor support option
Option for WINMAGplus basic license. Enables the allocation of 4 monitors from a choice ​
of 8 monitors. This option only works with WINMAGplus.
8
This option requires a special graphics card with up to 8 outputs in the WINMAG hardware.
This option must be ordered per workstation which uses the multi-monitor option.
013655
9
WINMAGplus – AutoCAD option
10
Option for WINMAGplus basic license. Enables the placement of detectors and groups ​
directly from ACAD LT. The drawings are saved as dxf files. The detectors/groups are ​
placed as hyperlinks in the ACAD drawing and stored. When importing these ACAD draw­
ings into WINMAGplus, the symbols of the disciplines are automatically placed onto the ​
correct position in the drawing. An ACAD license must be provided by the customer.
11
Please use order form printed in the appendix.
12
013614
WINMAGplus – OEM option
1
Option for WINMAGplus basic software for customizing WINMAGplus to individual ​
customer-specific wishes.
May cause changes to symbols/text and the front end.
13
These licenses may be ordered separately (as a subsequent optional update) only in conjunction ​
with the auxiliary number 013609. The update number of the basic license must be included ​
when ordering.
14
Please use order form printed in the appendix.
15
65
Management Systems
WINMAGplus
Application Example
1.
WINMAGplus single station system with an essernet connection
FACP
max. 1000 m
max. 15 m
Serial
essernet
interface
essernet
max. 1000 m
WINMAGplus control centre
WINMAGplus software requirements:
1 x CD WINMAGplus control center software
1 x Basic license WINMAGplus control center software
1 x License fire detection technology
Part No. 013610
Part No. 013631
Part No. 013626
2.
WINMAGplus multi station system - one server and two clients
FACP
with an essernet connection
max. 1000 m
max. 1000 m
max. 100 m
max. 15 m
WINMAGplus server
Serial
essernet
interface
LAN
LAN
WINMAGplus client 1
WINMAGplus software requirements:
1 x CD WINMAGplus control center software
1 x Basic license WINMAGplus control center software
1 x Licence fire detection technology
2 x License WINMAGplus client
66
www.hls-austria.com
WINMAGplus client 2
Part No. 013610
Part No. 013631
Part No. 013626
Part No. 013625
essernet
max. 1000 m
Management Systems
WINMAGplus
1
Application Example
3.
2
FACP
WINMAGplus multi station system - one server and two clients
with a multi subsection connection
IAP
3
max. 15 m
Video technology
crossbar or digital
video recorder e. g.
WINMAGplus server
max. 100 m
IGIS-Loop
4
IGIS-LOOP
controller
5
IAP
6
LAN
7
WINMAGplus client 1
WINMAGplus client 2
WINMAGplus software requirements:
1 x CD WINMAGplus control center software
1 x Basic licence WINMAGplus control center software
1 x License intrusion detection technology
1 x License fire detection technology
1 x License access control technology
1 x License video technology
2 x License WINMAGplus client
8
Part No. 013610.10
Part No. 013631.10
Part No. 013601.10
Part No. 013626.10
Part No. 013603.10
Part No. 013604.10
Part No. 013625.10
ACS 2 plus
Access control
IQMultiAccess
4.
9
10
FACP
WINMAGplus multi station system - 1 main server,
1 redundant server, 3 client workstations
- with an essernet connection
11
max. 15 m
max. 100 m
WINMAGplus server 1
Serial
essernet
interfaces
max. 15 m
FACP
12
essernet
13
WINMAGplus server 2
LAN
14
FACP
15
WINMAGplus client 1
WINMAGplus software requirements:
Server 1
1 x CD WINMAGplus control center software
1 x Basic license WINMAGplus control center software
1 x License fire detection technology
4 x License WINMAGplus client
1 x License option redundance
WINMAGplus client 2
Part No. 013610.10
Part No. 013631.10
Part No. 013602.10
Part No. 013625.10
Part No. 013624.10
WINMAGplus client 3
Server 2
1 x Basic license WINMAGplus control center software
Part No. 013631.10
1 x License fire detection technology
Part No. 013610.10
67
Management Systems
WINMAGLite
Digital Recorder
Fusion e. g.
SEI
FAP
or
IAP
or
Access
Control
WINMAGLite
Application example
013635
WINMAGLite with USB dongle
WINMAGLite is a cost effective first step to hazard detection systems management. Ease of​
operability as well as pre-defined, practical central control panel and detection point types ​
facilitate the commissioning and operation of WINMAGLite.
Features
• Cost-effective management software for hazard ​
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
detection systems
Visualizing and controlling of only one hazard ​
detection central control panel (FDS, VAPA, IDS, ​
RRT, AC)
Visualizing and controlling of VisiOprime or ​
Fusion video management systems
Management of up to 500 detection points
Processing of up to 100 status reports per second
Processing of up to 100 macro processes
Connection of log and alarm printers
Information display via monitor and/or printer ​
(Windows standard printer)
Adjustable program background
Flexible, window-oriented graphics
Display and location of detectors in diagrams
Status information indicators
Pre-defined alarm reports
Simulation function
Extensive event and operation logging
Users possible
WINMAGLite is perfect for small systems for which no expansions or connection of further ​
hazard detection control panels are planned in the near future. Thus, the Lite version is ​
perfectly suitable for a broad range of applications, even for WINMAG professionals.
Especially small objects can be professionally secured due to a combination of a hazard ​
detection system with the Honeywell video management systems of Honeywell VisiOprime. ​
WINMAGLite provides the user with almost all basic WINMAG functions. Unlike the full ​
version, this version can initially connect only one hazard detection central control panel.
The user has access to pre-defined programs which can automatically be adjusted via a ​
text editor to the respective situation on site.
The alarm stack which was implemented in previous WINMAG versions is replaced t​hrough
symbols displayed in the top bar which indicate alarms. The new feature improves ​overall
clarity so that the user can react more quickly in the case of an alarm.
Hardware and software requirements:
Pentium processor 3 GHz or higher, min. 512 MB RAM , min. 1 GB hard disk, XGA graphics card ​
with min. 4 MB video memory, monitor with 1024 x 768 pixels or more, sound card with ​
external speakers, Windows XP Professional SP2, Vista, Windows 7 and Windows 2003 Server,
Internet Explorer ​6.0 or higher.
Please use order form printed in the catalog.
Training for this product is offered. Please contact our training department.
Basic CD control center software package WINMAGLite
Accessories
Please take note that for connecting one essernet is needed consisting of SEI and fire alarm system.
013636
WINMAGLite upgrade to WINMAGplus full version
If the WINMAGLite system limits have been reached, an upgrade to the full version of ​
Winmagplus is possible, since both systems have access to the same database. WINMAG ​
options are not part of the upgrade and must be ordered separately.
WINMAGplus options are not included in the upgraded version and must be ordered separately.
Please use order form on www.esser-systems.com.
68
www.hls-austria.com
Management Systems
Difference WINMAGLite vs. WINMAGplus
1
Difference WINMAGLite vs. WINMAGplus
2
Differences between WINMAG Lite and WINMAG plus
WINMAG Lite is the inexpensive starter version of the hazard management system WINMAG plus with reduced features. It is used
for visualization and control of a single hazard detection control panel. The following table shows the most important features of
both programs.
In this comparison, you can see whether WINMAG Lite is sufficient for an application or WINMAG plus must be used.
The data structure of WINMAG Lite and WINMAG plus is identical. It is possible to change from WINMAG Lite to the full version.
Item No.
Interfaces
I/O points per object
Setting of I/O points
Special I/O Types
Event display
Meta data
Alarm stack
User
Tool bars
SIAS-programs
SIAS language
Alarm display
Alarm criteria
Graphics
Supported monitors
Number of graphics
Graphics displayable at once
Symbol actions
Creating special symbols
Multi station functions
Mandantory
Timer programs
State monitoring
Printer allocation
Licensing
System configuration list
WINMAG Lite
013635
1 hazard detection control + any
Fusion video devices
500
individual
yes
yes
yes
not available
3 predefined, can be renamed
predefined
predefined, no special programs
no individual programming
counter and pop-ups with individual text
predefined
identical to WINMAG plus, but without
- multi-monitor
- AutoCAD
2
unlimited
13
predefined list
no
no
no
no
no
1
dongle without options
3
4
WINMAG plus
013630/13631+ Options
as desired, depending on options
5
32000
individual
yes
yes
yes
yes
unlimited, free definable
configurable
configurable, extensible
full featured
identical to WINMAG Lite, in addition
alarm programs with alarm stacks
configurable
several formats like
- bmp, jpg, png, emf, wmf
- AutoCAD-Integration (optional)
4 from 8 (optional)
unlimited
48
configurable, special functions
yes
yes
yes
yes
yes
15
dongle with options
6
7
8
9
10
11
12
13
14
15
69
Notes
70
www.hls-austria.com
1
2
3
4
5
6
7
8
9
10
Automatic Detectors
Detector Series 9000 Conventional
72
Series IQ8Quad (Intelligent Addressable)
73-84
Detectors for Hazardous Areas
85-89
Base Series IQ8Quad
Accessories
90
11
12
91-104
13
14
15
71
Automatic Detectors
Features
• Detector series preferably for connection to third-​
party control panels
• Detector series can be used with all ESSER fire ​
alarm panels
• All detectors without switch-on-control
• Green marking on housing for heat detectors
• Up to 30 detectors can be connected per zone
• Rated voltage UN = 9 V
• Low closed-circuit current
• The detector alarm current can be programmed ​
for the adaptation to other manufacturer’s panels
• Large operating voltage range
• Detector design based on SMD technology
• All detectors can be programmed on one primary ​
Detector Series 9000 Conventional
Automatic conventional fire detectors with high reliability used for premises and items of ​
property with low and medium concentration of valuable assets.
The detector alarm current can be adjusted for 12V zone voltage to max. 50mA by means ​
of connecting a resistor of 1kohm to max. 62ohm located between terminals 4 and 5. ​
Resistor value can be calculated with the following formula: R = 2.4V / (I alarm - 9.4mA)
Technical Data
Operating voltage
Alarm current @ 9 V DC
Display
Storage temperature
Air humidity
Type of protection
Material
Color
Weight
Dimensions
loop
• Standard detector base 781590, detector base ​
•
•
•
•
•
•
781588 with relay output (30 V / 1 A) or detector ​
base 781592 with optocoupler output ​
(30 V / 0.4 A) can be used for all series 9000 ​
detectors
Easy installation
Pre-mounting plate with snap-in adapter
Detector base with base adapter 781498 up to ​
IP43
Optional detector lock
Detector removal tool for max. 9 m mounting ​
height
Reverse polarity protected
761306
8 ... 28 V DC
typ. 9 mA
red LED / light pipe
-25 °C ... 75 °C
≤ 95% (without condensation)
IP40, IP43 with base adapter 781498
ABS
white, similar to RAL 9010
approx. 90 g
Ø: 90 mm H: 61 mm
Ø: 90 mm H: 72 mm (incl. base)
Accessories
767800 Mounting bracket
781590 Detector base for series 9000/9200
781588 Detector base with relay contact for series 9000
Optical smoke detector incl. base with relay output for base ​transceiver
stations (BTS)
1
The conventional detector with relay contact (Part. No. 761306) consists of a Series 9000 ​
optical smoke detector (Part. No. 761362) and a detector base which facilitates a direct ​
connection to a 48 V DC voltage supply. Thus the detector does not have to be operated in ​
connection
with a fire alarm control panel. If the detector detects a fire alarm, a floating relay contact ​
switches and the alarm can then be forwarded. The relay contact is set to "normally closed" ​
by default, but can also be configured to "normally open" with a
soldered link on the base circuit board. A typical application for this detector is the monit­
oring of mobile stations.
Technical Data
Operating voltage
Quiscent current
Area to be monitored
Height to be monitored
Application temperature
42 ... 58 V DC
ca. 40 μA
max. 110 m²
max. 12 m
-20 °C ... 72 °C
Included is a special base with relay output.
72
www.hls-austria.com
Automatic Detectors
Series IQ8Quad (Intelligent Addressable)
1
Automatic intelligent fire detectors with high reliability, used for premises and items of ​
property with medium and high concentration of valuable assets.
Detector series IQ8Quad features, system advantages
Designed for optimal operation on System 8000, IQ8Control and FlexES Control fire alarm
systems.
with multisensor detectors for the detection of all types of fires, even under the most diffi­
cult operating conditions.
Detector with and without loop isolator
2
3
Different options of installation
-wiring in loop and spur combination, e.g.
-maximum number of detectors with cable lengths of up to 3500 m with installation cable ​
for fire detection, e.g. cables I-Y(St)Yn x 2 x 0.8 mm
-up to 127 detectors and detector zones per loop installation
-up to 32 detectors per zone
4
Easy commissioning
5
-automatic detector addressing
-fixed address assignment of detector location, even after detectors have been replaced or ​
added
-localization of wire breaks and short circuits on loop
-detector-LED used as alarm indicator and as an indicator for detectors in service
-adaptation to changing operating conditions
-dedicated LED for indicating operation (green LED)
-disconnection of individual detectors, detector zones and detection areas
-disconnection of individual sensors or several sensors at once within a multisensor ​
detector; either manually or depending on programmed time of the day
6
7
Automatic adaptation to varying environmental conditions
8
-compensation of changing levels of air pressure, humidity, smoke concentration ​according to the double chamber principle
-electronic compensation of long-term influences like aging or pollution
9
Reliable detection
-constant alarm sensitivity of multisensor detector for all types of fire
-large signal to noise ratio due to the special design of the sensors and the electronics to ​
suppress electromagnetic interference
10
Reliable false alarm suppression
-high immunity against false alarms by means of timed evaluation of different sensor ​
criteria
-signal patterns not typical for fires are eliminated by using special filter algorithms
-automatic self-monitoring of detector electronics
-continuous loop monitoring even during short-circuits through isolating the relevant ​
segment
-automatic monitoring of all sensors to guarantee operational capacity and correct condi­
tion.
11
12
Increased operating reliability
-short-circuit and wire break tolerant through monitoring from both ends of the loop
-alarm decision inside detector
-fail-safe circuit activated if communication fails
13
Maintenance
-automatic maintenance request
-heat detector identification through a black circle on the light transmission plate
-multisensor gas detector identification through a golden loop on the circle transmission ​
plate
-operating time-, alarm- and fault counter in each detector
-automatic, cyclic loop check
-complete status interrogation from the control panel
-interrogation of operating data from all detectors on loop via standard service PC and ​
detector interface
14
15
Comprehensive range of accessories
-standard detector base and relay base
-base adapter for ceiling mounting
-dust cover for fire detector or detector base
-kit for suspended ceiling mounting
-RF base
73
Automatic Detectors
Series IQ8Quad (Intelligent Addressable)
Detector without Integrated Alarm Devices
Technical Data
117
62
Fire detector with base
Alarm current w/o communication curtain
Air speed
Storage temperature
Air humidity
Type of protection
Material
Color
Weight
Dimensions
approx. 18 mA
0 ... 25.4 m/s
-25 °C ... 75 °C
< 95 % (non-condensing)
IP 43 (with base + option)
ABS plastic
white, similar to RAL 9010
approx. 110 g
Ø: 117 mm H: 49 mm (62 mm incl. base)
Special-color on demand
The detectors part no. 802271, 802371, 802373 and 802374 are ​approved in the scope of the
DIBt system authorization for the operation with an Automatic Door ​System.
Detector base is not supplied as standard
Accessories
767800 Mounting bracket
805590 Standard detector base for IQ8Quad
805591 Detector base with relay contact for IQ8Quad
802171
Fixed heat detector IQ8Quad
1
Approval: VdS, BOSEC
Automatic heat detector with fast semiconductor sensor to guarantee reliable detection of ​
fires with strong heat generation. Intelligent fire detector with decentralized intelligence, ​
automatic function self-test, CPU failure mode, alarm and operating data memory, alarm ​
indicator, soft-addressing and operating indication.
The detector is provided with an integrated isolator. A parallel detector indicator can be ​
connected.
Technical Data
Operating voltage
Quiescent current @ 19 V DC
Area to be monitored
Height to be monitored
Application temperature
Detector specification
8 ... 42 V DC
approx. 40 μA
max. 30 m²
max. 7.5 m
-20 °C ... 50 °C
EN 54 - 5 A1S / -17
Special marking for heat detector on the light pipe: black ring.
802177
Fixed heat detector class B IQ8Quad
1
Approval: VdS
As 802171, but for increased operating temperature according to EN 54-5 Class B.
Technical Data
Operating voltage
Quiescent current @ 19 V DC
Area to be monitored
Height to be monitored
Application temperature
Detector specification
8 ... 42 V DC
approx. 40 μA
max. 30 m²
max. 6 m
-20 °C ... 65 °C
EN 54-5 BS / -17
Special marking for heat detector on the light pipe: black ring.
74
www.hls-austria.com
Automatic Detectors
802271
Series IQ8Quad (Intelligent Addressable)
1
Rate-of-rise heat detector IQ8Quad
1
Approval: VdS, BOSEC
2
Automatic heat detector with fast semiconductor sensor to guarantee reliable detection of ​
fires with rapidly rising temperatures and integrated fixed temperature function for the ​
detection of fires with slowly rising temperatures. Intelligent fire detector with decentral­
ized intelligence, automatic function self-test, CPU failure mode, alarm and operating data ​
memory, alarm indicator, soft-addressing and operating indication.
The detector is provided with an integrated isolator. A parallel detector indicator can be ​
connected.
3
4
Technical Data
Operating voltage
Quiescent current @ 19 V DC
Area to be monitored
Height to be monitored
Application temperature
Detector specification
8 ... 42 V DC
approx. 40 μA
max. 30 m²
max. 7.5 m
-20 °C ... 50 °C
EN 54-5 A1 / -17
5
6
Special marking for heat detector on the light pipe: black ring.
7
802371
Optical smoke detector IQ8Quad
1
Approval: VdS, BOSEC
8
Optical smoke detector to guarantee safe and early detection of fire. Intelligent fire detector ​
with decentralized intelligence, automatic function self-test, CPU failure mode, alarm and ​
operating data memory, alarm indicator, soft-addressing and operating indication. The ​
detector is provided with an integrated isolator. A parallel detector indicator can be ​
connected.
9
Technical Data
10
Operating voltage
Quiescent current @ 19 V DC
Area to be monitored
Height to be monitored
Application temperature
Detector specification
8 ... 42 V DC
approx. 50 μA
max. 110 m²
max. 12 m
-20 °C ... 72 °C
EN 54-7 / -17
11
12
802373
OT multisensor detector IQ8Quad
1
13
Approval: VdS
Multisensor detector with integrated optical detector and heat detector, with time-​controlled signal analysis and weighted data combination of both detector functions for ​detecting smouldering fires and fires with extreme heat generation. Intelligent detector with ​
decentralized intelligence, self-function test, CPU redundancy mode, automatic adaptation ​
to the environments, alarm and operating data storage, alarm indication and soft ​addressing.
The loop isolator is integrated in the detector. A parallel detector indicator is additionally ​
attachable.
14
15
Technical Data
Operating voltage
Quiescent current @ 19 V DC
Area to be monitored
Height to be monitored
Application temperature
Detector specification
9 ... 42 V DC
approx. 50 μA
max. 110 m²
max. 12 m
-20 °C ... 50 °C
EN 54-7/-5 A2 /-17, CEA 4021
75
Automatic Detectors
802375
Series IQ8Quad (Intelligent Addressable)
OTblue multisensor detector IQ8Quad
1
Approval: VdS
Multisensor with integrated optical detector and heat detector. The optical measurement ​
chamber is provided with a newly developed sensor technology, enabling the detection of ​
open fires, smouldering fires and fires with high heat generation. Especially for open fires, ​
the classical ionization technology implemented in ionization detectors is replaced by the ​
new detection technology. The detector is capable of identifying the TF1 and TF6 test fires ​
described in the EN 54-9:1982 specification.
The OTblue multisensor is an intelligent detector with time-related signal analysis, signal ​
correlation of the sensor data, decentralized intelligence, automatic function self-test, CPU ​
failure mode, automatic adaptation to environmental conditions, alarm and operating data ​
memory, alarm indicator and soft-addressing.
The detector is provided with an integrated isolator and a parallel detector indicator can be ​
connected.
Technical Data
Operating voltage
Quiescent current @ 19 V DC
Area to be monitored
Height to be monitored
Application temperature
Material
Detector specification
802374
9 ... 42 V DC
approx. 50 μA
max. 110 m²
max. 12 m
-20 °C ... 50 °C
ABS
EN 54-7/-5 A2 /-17, CEA 4021
O2T multisensor IQ8Quad
1
Approval: VdS, BOSEC
Multisensor detector provided with two built-in optical smoke sensors with different s​ cattered light angles as well as additional heat detector sensor evaluation to guarantee the ​
detection of different types of fire from smouldering fires to open fires with constant sens­
itivity level. Smoke sensor signal identification to ensure smoke classification and reduc­
tion of deceptive alarms caused, for instance, by water vapor or dust.
Because of its excellent detection characteristics, the detector is also able to identify the ​
standardized TF1 and TF6 test fires. The O²T multisensor detector is also suitable for ​applications with higher temperatures of up to +65 °C. The detector is provided with an ​integrated isolator. A parallel detector indicator can be connected.
Technical Data
Operating voltage
Quiescent current @ 19 V DC
Area to be monitored
Height to be monitored
Application temperature
Detector specification
76
www.hls-austria.com
8 ... 42 V DC
approx. 60 μA
max. 110 m²
max. 12 m
-20 °C ... 65 °C
EN 54-7/-5 B /-17, CEA 4021
Automatic Detectors
802473
Series IQ8Quad (Intelligent Addressable)
1
OTG multisensor (CO) IQ8Quad
1
Approval: VdS
2
Multisensor detector with integrated smoke detector, heat detector and gas sensor (CO) for ​
preventive and early detection of fires ranging from smouldering fires to open fires through ​
combined evaluation of scattered light, temperature and gas. An alarm is actuated at ​
carbon monoxide (CO) concentration levels that are life-threatening for humans. The ​
detector is provided with an integrated isolator. A parallel detector indicator can be ​
connected.
Gas sensor (CO) helps to detect fire alarms, but can additionally serve to signal technical
alarm when concentration exceeds safe value without fire situation.
3
4
Technical Data
Operating voltage
Quiescent current @ 19 V DC
CO pre-alarm
CO alarm
Area to be monitored
Height to be monitored
Application temperature
Detector specification
8 ... 42 V DC
approx. 65 μA
approx. 75 ppm
approx. 100 ppm
max. 110 m²
max. 12 m
-20 °C ... 50 °C
EN 54-7/-5 A2 /-17, CEA 4021
5
6
In the course of installation, we recommend testing the integrated CO sensor with our CO test ​
gas (Part no. 805583) or CO capsule (Part no. 805553).
Durability CO sensor: approx. 5 years
Technical alarm range CO: 10 ppm … 150 ppm
7
Gas sensors (CO) mainly react to the carbon monoxide arising from a fire (CO). They have, ​
however, also a cross sensitivity to other gases, as for example hydrogen (H2), acetylene (C2H2) ​
or nitric oxide (NO).
8
Special marking for gas detector on the light pipe: gold ring.
9
10
11
12
13
14
15
77
Automatic Detectors
Series IQ8Quad (Intelligent Addressable)
O2T Detector with Integrated Alarm Devices
Features
Detection
• The reliable O²T multisensor principle for ​consistent response performance at the highest ​level of
security against false alarms
Flash lamp
• Loop powered - no need for external power ​
supply
• No additional short address
• Automatic synchronization of various IQ8Quad ​
alarm signaling devices
• High flash energy
Sounder
• Loop powered - no need for external power ​
supply
• No additional short address
• Automatic synchronization of various IQ8Quad ​
alarm signaling devices
• Maximum sound level: 92 dB (A) at 1 m
• Maximum sound pressure can be set
• Multiple signal patterns can be combined to one ​
signal
• Signal pattern and repetition rates can be set
• 20 different signal tones, incl. DIN-tone
Speech massage with sounder
• Loop powered - no need for external power ​
supply
• No additional short address
• Automatic synchronization of various IQ8Quad ​
alarm signaling devices
• Maximum sound level: 92 dB (A) at 1 m
• Maximum sound pressure can be set
• Multiple signal patterns can be combined to one ​
signal
• Signal pattern and repetition rates can be set
• 20 different signal tones, incl. DIN-tone
• Speech messages can be played in up to 5 ​languages
• 5 alarm messages per languages are prepro­
grammed
The IQ8Quad smoke detectors with built-in alarm device incorporate up to 4 different func­
tionalities (detect, flash, sound, and/or speech) depending on the type (O²T/F, O²T/So, O²T/​
Sp, O²T/FSp) of detector.
- fire detection as per EN 54-7
- integrated heat sensor as per EN 54-5
- optical alarm via flash lamp
- acoustic alarm via sounder as per EN 54-3/A2
- acoustic alarm speech messages as per EN 54-3/A2
- short-circuit isolator as per EN 54-17
Detection
Multisensor detectors with two built-in optical smoke sensors with different scattered light ​
angles as well as additional heat detector sensor evaluation for detecting everything from ​
smouldering fires to open fires with consistent response performance. Smoke sensor ​
signal identification to ensure smoke classification and reduction of false alarms caused, ​
for instance, by water vapor or dust. Each detector is provided with an integrated isolator.
Alarm signaling
The alarm signaling device is activated by the control panel. No further short address ​
needs to be allocated. It is programmed with tools 8000 as of software version 1.05.
Alarm tone / speech message programming
For detectors with speech message and/or alarm tone function with up to five language ​
options, up to 4 signals can be programmed. Two signals are reserved for alarm signaling ​
and evacuation in the case of fire. Two further signals can be programmed for other events.​
Each signal can consist of up to four signal components, enabling one signal to be ​
programmed as a DIN tone combined with subsequent speech messages in three different ​
languages.
Alarm tones can be chosen from a table with various tone types. For application in schools, ​
a break signal to signify the breaks between class can be activated.
Four different speech messages, each in three languages, are available:
- "An incident has been reported in the building. Please await further instructions.”
- "Attention” please. This is an emergency. Please leave the building by the nearest avail­
able exit.”
- "This is a fire alarm. Please leave the building immediately by the nearest available exit.”
- “This is a test message. No action is required. “
When the basic setting is selected, signals / signal components can be continuously ​
repeated until the signalling function is interrupted by the control panel. They can also be ​
programmed with a repetition rate of one to three times. Thus, the break signal in schools ​
can be deliberately set to only one repetition. In the same way, the total signal can be set to ​
continuous repetition, with the DIN tone being played only once while subsequent speech ​
messages are played up to three times.
Sound pressure programming
The sound level [dB (A)] can be set to eight levels, from approximately 64dB (A) to approx­
imately 92dB (A).
78
www.hls-austria.com
Automatic Detectors
Series IQ8Quad (Intelligent Addressable)
1
All the security you need in one housing with four functions: detection, flasher, sounder ​
and speech alarm.
All IQ8Quad detectors with built-in alarm devices can only be operated on the powered loop. For ​
physical reasons, an increased sound level leads to a higher current consumption rate of the ​
alarm device, the respective load factor must be considered when calculating the maximum ​
number on the loop. Altogether up to 127 bus devices per loop can still be connected.
Please consider that extra training is required when dealing with IQ8Quad with a built-in alarm ​
device. The training includes installation planning and commissioning techniques. For further ​
information take a look at our training brochure. Information concerning the calculation can be ​
found in the "Project Planning Support“ chapter.
signal 1
(evacuation)
sequence 1
sequence 2
sequence 3
sequence 4
signal 2
(alarm)
sequence 1
sequence 2
sequence 3
sequence 4
signal 3
(event 1)
sequence 1
sequence 2
sequence 3
sequence 4
signal 4
(event 2)
sequence 1
sequence 2
sequence 3
sequence 4
2
3
4
5
6
Signals
7
8
9
10
11
12
13
14
15
79
Automatic Detectors
Series IQ8Quad (Intelligent Addressable)
O2T Detector with Integrated Alarm Devices
Country code
acc. to ISO
3166 -Alpha-2
Language
code acc.
to ISO 639-1 Evacuation 1
de
Germany
(DE)
en
Great Britain
(GB)
fr
France
(FR)
es
Spain
(ES)
it
Italy
(IT)
Evacuation 2
Alarm
Testmessage
All-Clear
Dies ist ein
Feueralarm. Bitte
verlassen Sie das
Gebäude umgehend über die
nächsten Fluchtwege. Die Feuerwehr ist alarmiert.
Achtung, Achtung!
Dies ist eine Gefahrenmeldung. Bitte
verlassen Sie das
Gebäude über die
nächsten
Ausgänge.
Achtung, im Gebäude ist eine
Gefahrensituation
gemeldet worden.
Bitte bleiben Sie
ruhig, und warten
Sie auf weitere
Anweisungen.
Dies ist eine
Testdurchsage.
Die Gefahrensituation
ist jetzt behoben. Wir
entschuldigen uns
für jegliche
Unannehmlichkeiten.
This is a fire alarm.
Please leave the
building immediately by the nearest
available exit.
Attention please.
This is an emergency. Please leave the
building by the
nearest available exit.
An incident has
been reported in the
building. Please
await further
instructions.
This is a test
message.
No action is
required.
The emergency is
now cancelled. We
apologize for any
inconvenience.
Ceci est une alarme
incendie,veuillez
évacuer
immédiatement les
locaux par la sortie
la plus proche.
Votre attention s'il
vous plaît, ceci est
une alarme. Veuillez
évacuer les locaux
par la sortie la plus
proche.
Un incident est
signalé dans le
batiment. Merci de
garder votre calme
et attendez les
prochaines
instructions.
Ceci est un test.
L'alarme est à
présent annulée.
Veuillez nous excuser
pour le désagrément.
Esto es una alarma
de incendio.
Abandonen
por favor el edificio
inmediatamente
por la salida de
evacuación
más cercana.
Atención. Esto es
una emergencia.
Por favor
abandonen el
edificio por la
salida de
evacuación
más cercana.
Atención, se ha
reportado un
incidente
en el edificio.
Aguarden por favor
otras instrucciones.
Esto es un
mensaje
de prueba.
No se requiere
ninguna acción.
La emergencia ha
sido cancelada.
Pedimos disculpas
por las molestias
causadas.
Attenzione.
Allarme incendio.
Abbandonare
l'edificio tramite
l'uscita di
emergenza più
vicina.
Attenzione.
Allarme in corso.
Vi preghiamo di
recarvi presso
l'uscita di
emergenza più
vicina.
Attenzione.
E' stato rilevato un
allarme.Ulteriori
disposizioni vi
verranno
comunicate
appena possibile.
Attenzione.
E' in corso una
prova di allarme.
Non è richiesta
alcuna azione.
Attenzione. Cessato
allarme.La situazione
di normalità è stata
ripristinata.
Standard speech messages of IQ8Quad detectors and IQ8Alarm
No.
Description
Frequency
School bell
complex
2
FP 1063.1 Telecoms
BS 5839 Pt1
Alternating 800 / 970 Hz at 2 Hz
3
BS 5839 Pt1
Alternating 800 / 970 Hz at 1 Hz
f
4
BS 5839 Pt1
Intermittent 970 Hz at 1 Hz 0.5 sec.
f
5
BS 5839 Pt1
Intermittent 2850 Hz at 1 Hz 0.5 sec.
f
6
BS 5839 Pt1
Intermittent 970 Hz 1/4 sec. ON - 1 sec. OFF
f
7
BS 5839 Pt1
Continuous 970 Hz
f
8
BS 5839 Pt1
Sweep tone 800 Hz tp 970 Hz at 7 Hz
f
9
BS 5839 Pt1
Sweep tone 800 Hz to 970 Hz at 1 Hz
f
10
DIN Tone
DIN 33404 Part 3
1200 - 500 Hz at 1 Hz
f
11
French fire sound
554 Hz / 100 ms + 440 Hz / 400 ms + 10 %
f
12
NL - Slow Whoop
500 Hz - 1200 Hz at 3.5 sec. break of 0.5 sec.
f
13
US - Horn
Continuous 485 Hz
f
14
US - Horn with
Temporal Pattern
Intermittent 485 Hz
(0.5 sec. ON; 0.5 sec. OFF; 3 times; 1.5 sec. OFF; Repeat)
f
15
US - March
Time
Alternating 485 Hz
(0.25 sec. ON; 0.25 sec. OFF; Repeat)
f
16
US - Slow
Whoop
Sweep tone 500 Hz to 1200 Hz
(4.0 sec. ON; 0.5 sec. OFF; Repeat)
f
17
US - Siren
18
US - Hi/Lo
Sweep tone 600 Hz to 1200 Hz
(1.0 sec. ON, Repeat)
Alternating 100 Hz / 800 Hz
(0.25 sec. ON; Alternate; 0.25 sec. ON; Alternate; Repeat)
19
US - NFPA
Whoop
IMO
GA-Signal
Sweep tone 422 Hz to 775 Hz
(upwards sweep 0.85 sec.; 3 times; 1 sec. OFF; Repeat)
Intermittent 800 Hz (1,0 sec. ON; 1,0 sec.
OFF: 7 times; 2.0 sec. ON: 2.0 sec. OFF; Repeat)
20
IQ8Quad detector and IQ8Alarm tone table
80
Pulse rate
1
www.hls-austria.com
complex
f
0,25 sec.
0,25 sec.
t
0,5 sec.
0,5 sec.
0,5 sec.
0,5 sec.
0,5 sec.
0,5 sec.
0,25 sec.
t
1,5 sec.
t
1,5 sec.
1,0 sec.
t
t
t
10 ms
t
1,0 sec.
t
1,0 sec.
t
0,1 sec.
0,4 sec.
t
3,5 sec. 0,5 sec.
t
t
0,5 sec.
1,5 sec.
0,5 sec.
f
f
f
f
t
0,25 sec.
0,25 sec.
t
4,0 sec. 0,5 sec.
t
1,0 sec.
t
0,25 sec.
0,25 sec.
0,85 sec.
1,0 sec.
1,0 sec.
t
1,0 sec.
t
t
Automatic Detectors
Series IQ8Quad (Intelligent Addressable)
1
Detector with Integrated Alarm Devices
Technical Data
117
65
Fire detector with base
Operating voltage
Area to be monitored
Height to be monitored
Air speed
Application temperature
Storage temperature
Air humidity
Type of protection
Material
Color
Weight
Dimensions
2
8 ... 42 V DC
max. 110 m²
max. 12 m
0 ... 25.4 m/s
-20 °C ... 65 °C
-25 °C ... 75 °C
≤ 95 % (without condensation)
IP 42
ABS plastic
white, similar to RAL 9010
approx. 145 g
Ø: 117 mm H: 59 mm
Ø: 117 mm H: 67 mm (incl. base)
3
4
Detector bases are not supplied as standard.
The 769836 demo package is available for presentations. Further data can be viewed in the ​
accessories section for automatic detectors.
5
Special-colors on demand!
6
It is not possible to use the detector base with relay (part no. 805591).
7
When connected with parallel indicator does not allow to program parallel indicator.
Detector base is not supplied as standard
8
Accessories
767800 Mounting bracket
805590 Standard detector base for IQ8Quad
9
IQ8Control C
10
flash
signal
11
speech
12
esserbus-PLus
Loop length max. 3.5 km
13
14
speech
esserbus transponder
15
flash
sound
speech
Application example
81
Automatic Detectors
802383
Series IQ8Quad (Intelligent Addressable)
O2T/F multisensor IQ8Quad
1
Approval: VdS
O²T/F multisensor IQ8Quad with integrated flasher
In addition to smoke detection with the conventional O²T multisensor technology, the ​
detector is provided with a built-in flash lamp.
Technical Data
Quiescent current @ 19 V DC
Load factor
Lighting energy
Strength of light
Signal flashing lamp
Detector specification
approx. 75 μA
2
approx. 3 Y
max. 15,8 cd peak / 2,63 cd effective
red
EN 54-7/-5 B/-17, CEA 4021
Not suitable for application in detector base 805591!
802382
O/So optical smoke detector IQ8Quad
1
Approval: VdS
O/So optical smoke detector IQ8Quad with integrated sounder
Scatter smoke detector for safe and early detection of smouldering fires with light smoke ​
generation. Intelligent detector with decentralised intelligence, automatic function self-test, ​
CPU failure mode, alarm and operating data memory, alarm indicator, soft-addressing and ​
operating indication. The detector is provided with a loop isolator.
Along with smoke detection components, the detector is provided with a built-in sounder.
Technical Data
Quiescent current @ 19 V DC
Load factor
Sound level
Detector specification
Specification
approx. 50 μA
2
max. 92 dB (A), +/- 2 db (A) @ 1m for DIN tone
EN 54-7, EN 54-17
EN 54-3 acoustic signaling device
Not suitable for application in detector base 805591!
802384
O2T/So multisensor IQ8Quad
1
Approval: VdS
O²T/So multisensor IQ8Quad with integrated sounder
In addition to smoke detection with the conventional O²T multisensor technology, the ​
detector is provided with a built-in alarm signalling device. The sound level can be set to ​
eight different levels.
Technical Data
Quiescent current @ 19 V DC
Load factor
Sound level
Type of protection
Detector specification
Specification
approx. 80 μA
2
max. 92 dB (A), +/- 2 db (A) @ 1m for DIN tone
IP 42
EN 54-7/-5 B/-17, CEA 4021
EN 54-3 acoustic signaling device
Not suitable for application in detector base 805591!
82
www.hls-austria.com
Automatic Detectors
802386
Series IQ8Quad (Intelligent Addressable)
1
O2T/Sp multisensor IQ8Quad
1
Approval: VdS
2
O²T/Sp multisensor IQ8Quad with integrated sounder and speech
In addition to smoke detection with conventional O²T multisensor technology, the detector ​
is provided with a built-in voice alarm device. It can be set to eight different levels.
3
Technical Data
Quiescent current @ 19 V DC
Load factor
Sound level
Detector specification
Specification
approx. 90 μA
3
max. 92 dB (A), +/- 2 db (A) @ 1m for DIN tone
EN 54-7/-5 B/-17, CEA 4021
EN 54-3 acoustic signaling device
EN 54-3 acoustic speech signaling device
4
5
Not suitable for application in detector base 805591!
Programmed with 5 standard languages: German, English, Spanish, French and Italian
802385
6
7
O2T/FSp multisensor IQ8Quad
1
Approval: VdS
8
O²T/FSp multisensor IQ8Quad with integrated flasher, sounder and speech
In addition to smoke detection with the conventional O²T multisensor technology, the ​
detector is provided with a built-in voice alarm device. It can be set to eight different levels.
9
Technical Data
Quiescent current @ 19 V DC
Load factor
Sound level
Lighting energy
Strength of light
Signal flashing lamp
Detector specification
Specification
approx. 90 μA
3
max. 92 dB (A), +/- 2 db (A) @ 1m for DIN tone
approx. 3 Y
max. 15,8 cd peak / 2,63 cd effective
red
EN 54-7/-5 B/-17, CEA 4021
EN 54-3 acoustic signaling device
EN 54-3 acoustic speech signallng device
10
11
12
Not suitable for application in detector base 805591!
Programmed with 5 standard languages: German, English, Spanish, French and Italian
13
802386.SV98
O2T/Sp multisensor IQ8Quad, special language
1
14
Approval: VdS
As 802386, but special language.
When ordering, please note the “Ordering information for IQ8Quad and IQ8Alarm” and fill in ​
“Order form for individual combination of languages” printed in the appendix.
15
Programmed with individual combination of up to 5 standard languages.
83
Automatic Detectors
802386.SV99
Series IQ8Quad (Intelligent Addressable)
O2T/Sp multisensor IQ8Quad, customized version
1
Approval: VdS
As 802386, but with individual text and/or sounds. The max. recording time per device is ​
169 seconds.
When ordering, please note the “Ordering information for IQ8Quad and IQ8Alarm” and fill in ​
“Order form for individual combination of languages” printed in the appendix.
802385.SV98
O2T/FSp multisensor detector IQ8Quad with composition of other ​languages
1
Approval: VdS
O²T/FSp multisensor IQ8Quad with integrated flasher, sounder and speech
As 802385, but with an individual combination of national languages, see special order ​
form in the appendix.
When ordering, please note the “Ordering information for IQ8Quad and IQ8Alarm” and fill in ​
“Order form for individual combination of languages” printed in the appendix.
Cancellations or returns are not possible.
Not suitable for application in detector base 805591!
Programmed with an individual combination of up to 5 languages.
802385.SV99
O2T/FSp multisensor detector IQ8Quad, customized version
1
Approval: VdS
O²T/FSp multisensor IQ8Quad with integrated flasher, sounder and speech
As 802385, but with individual text and/or sounds. The max. recording time per device is ​
169 seconds.
When ordering, please note the "Ordering information for IQ8Quad and IQ8Alarm" and fill in ​
“Order form for individual combination of languages” printed in the appendix.
Costs for the recording of customer-specific texts and/or tones can be obtained by request.
Cancellations or returns are not possible.
Not suitable for application in detector base 805591!
Programmed according to customer specifications.
84
www.hls-austria.com
Automatic Detectors
Detectors for Hazardous Areas
1
IQ8Quad Ex (i) Intrinsically Safe
Technical Data
117
62
Fire detector with base
Data according to ATEX:
Max. Input Voltage (Ui)
Max. Input current (Ii)
Max. Output current (Io)
Max. internal capacity (Ci)
Ambient temperature (Ta)
EC-type examination certificate
Ex-category
Explosion protection
Common technical data:
Operating voltage
Alarm current @ 9 V DC
Air speed
Storage temperature
Type of protection
Material
Color
Weight
Dimensions
2
21 V DC
252 mA
10 mA
1 nF
-20 °C ... 70 °C
TÜV 09 ATEX 554910
II 2G (with Ex-Barrier Part No. 804744 or 764744)
Ex ib IIC T4 Gb
3
4
8 ... 42 V DC
typ. 18 mA
0 ... 25.4 m/s
-25 °C ... 75 °C
IP 43 (incl. base + option)
ABS
white, similar to RAL 9010
approx. 110 g
Ø: 117 mm H: 49 mm (62 mm incl. base)
5
6
Detector bases are not supplied as standard.
Additional detectors for the explosion zones can be found in the chapters manual call points and ​
special detectors. Detailed information about installation and operation can be found in the ​documentation part no. 798920.
7
All of the following IQ8Quad explosion-proof fire detectors must be operated with the 805590 ​
base. In the case of operation in standard zones, no individual addressing is possible!
8
For usage in zone 1 and zone 2 in case of operation
- with individual addressing the Ex-Barrier part no. 804744,
- in conventional zones the Ex-Barrier part no. 764744 must be used!
9
The Ex-Barrier separates intrinsically safe and non-intrinsically safe circuits before the explosion ​
prone area to be monitored (explosion zone).
10
Individual addressable operating
Zone 1
11
esserbus / esserbus-PLus
Ex area: IIC T2
12
Ex-Barrier (Part No. 804744)
Conventional operating
13
Zone 1
esserbus / esserbus-PLus
external power supply
Ex-Barrier (Part No. 764744)
14
Ex area: IIC T2
esserbus transponder 4 zone / 2 relay
15
Application example
85
Automatic Detectors
803271.EX
Detectors for Hazardous Areas
Rate-of-rise detector IQ8Quad Ex (i)
1
Approval: G 209223
Automatic heat detector with quick semiconductor sensor for the reliable recognition of ​
fires with fast rate of temperature rise as well as integrated fixed temperature heat function ​
for the recognition of fires with slow temperature rise. Intelligent fire detector with decent­
ralized intelligence, automatic function self-test, emergency mode, storage of alarm and ​
operating data, alarm display. Soft addressing and separate operational display is only ​
possible when operating an esserbus / esserbus-PLus IQ8Quad detector without loop isol­
ator, especially for usage in explosion zones. Operation with individual addressing at Ex-​
Barrier 804744 and as standard detector at Ex-Barrier 764744.
Technical Data
Quiescent current @ 19 V DC
Area to be monitored
Height to be monitored
Application temperature
Detector specification
approx. 40 μA
max. 30 m²
max. 7.5 m
-20 °C ... 50 °C
EN 54-5 A1R
Special marking for heat detector on light pipe: black ring
Accessories
805590 Standard detector base for IQ8Quad
803371.EX
Optical smoke detector IQ8Quad Ex (i)
1
Approval: G 209224
Scattered-light smoke detector for reliable early recognition of fires. Intelligent fire detector ​
with decentralized intelligence, automatic function self-test, emergency mode, storage of ​
alarm and operating data, alarm display. Soft addressing and separate operational display ​
is only possible when operating an esserbus / esserbus-PLus IQ8Quad detector without ​
loop isolator, especially for usage in explosion zones. Operation with individual addressing ​
at Ex-Barrier 804744 and as standard detector at Ex-Barrier 764744.
Technical Data
Quiescent current @ 19 V DC
Area to be monitored
Height to be monitored
Application temperature
Detector specification
approx. 50 μA
max. 110 m²
max. 12 m
-20 °C ... 70 °C
EN 54-7
Accessories
805590 Standard detector base for IQ8Quad
803374.EX
O2T intelligent detector IQ8Quad Ex (i)
1
Approval: G 209225
Intelligent detector with two integrated optical smoke sensors with different scattered-light ​
angles as well as additional heat detector sensor evaluation for the recognition of smoul­
dering fires up to open fires with uniform characteristics. Comparison of the heat sensor ​
signals for smoke classification and reduction of deceptive alarms, e.g. from steam or ​
dust. Due to its excellent detection characteristics, the detector is also able to recognize ​
TF1 and TF6 test fires, described in the standards. The O²T intelligent detector is also suit­
able for a higher operating temperature of up to +65 °C. Intelligent fire detector with ​decentralized intelligence, automatic function self-test, emergency mode, storage of alarm ​and
operating data, alarm display. Soft addressing and separate operational display is only ​
possible when operating an esserbus / esserbus-PLus IQ8Quad detector without loop isol­
ator, especially for usage in explosion zones. Operation with individual addressing at Ex-​
Barrier 804744 and as standard detector at Ex-Barrier 764744.
Technical Data
Quiescent current @ 19 V DC
Area to be monitored
Height to be monitored
Application temperature
Detector specification
Accessories
approx. 60 μA
max. 110 m²
max. 12 m
-20 °C ... 65 °C
EN 54-7
805590 Standard detector base for IQ8Quad
86
www.hls-austria.com
Automatic Detectors
Detectors for Hazardous Areas
1
Ex-Accessories
804744
2
Ex-barrier for intrinsic safe detectors series IQ8Quad Ex (i)
1
Design certificate BAS 00 ATEX 7087
Ex-Barrier for the operation of intrinsically safe IQ8Quad Ex (i) series detectors directly on ​
the esserbus/esserbus PLus with individual addressing in connection with the detector ​
base 805590.
3
Technical Data
4
Ambient temperature
Type of protection
Weight
CE certificate
Dimensions
-20 °C ... 60 °C
IP 20
approx. 100 g
(CPD) EN 54-18:2005
W: 20 mm H: 107 mm D: 115 mm
5
A safety barrier does not replace an overvoltage protection according to IEC 801, DIN VDE 0185 ​
and 0855.
You can find more detailed information on the installation and the operation for IQ8Quad Ex (i) ​
Series detectors in the documentation part no. 798920.
System requirements
6
7
- Number of detectors up to max. 10 fire detectors per Ex barrier
- Max. 4 Ex barriers per loop.
- At least one esserbus device with a isolator must be installed between two Ex barriers.
- Total loop length up to max. 3500 m.
- For each Ex barrier the total loop length must be reduced about 200 meters.
- Cable length (spur) within the Ex area max. 400 m per Ex barrier.
- Load factor 3 per Ex barrier. (Use load factor calculation tool).
8
9
Individual addressable operating
Zone 1
10
esserbus / esserbus-PLus
Ex area: IIC T2
11
Ex-Barrier (Part No. 804744)
Application example
12
13
14
15
87
Automatic Detectors
764744
Detectors for Hazardous Areas
Ex-barrier for intrinsic safe detectors series IQ8Quad Ex (i) and ​9100
1
Design certificate BAS01 ATEX 7005
Ex-Barrier for the operation of intrinsically safe IQ8Quad Ex (i) series detectors in connec­
tion with the detector base 805590 as well as the 9100 Ex (i) series in connection with the ​
detector base 781590.
Technical Data
Ambient temperature (Ta)
Dimensions
-20 °C ... 60 °C
W: 12.5 mm H: 115 mm D: 110 mm
A safety barrier does not replace an overvoltage protection according to IEC 801,
DIN VDE 0185 and 0855. VdS approval is not required.
You can find more detailed information on the installation and the operation in the ​documentation part no. 798920 for IQ8Quad Ex (i) Series detectors and part no. 798913 for ​9100 Ex (i)
Series detectors.
System requirements
- Number of detectors up to max. 8 fire detectors per zone.
- Loop length per zone up to max. 300 m. (Total length measured from the terminals of the ​
detector zone).
Conventional operating
Zone 1
esserbus / esserbus-PLus
external power supply
Ex-Barier (Part No. 764744)
Ex area: IIC T2
esserbus transponder 4 zone / 2 relay
Application example
764745
Isolation and assembly block for safety barrier
1
For insulated (earth-free) mounting of 764744 barriers onto standard hat rail.
Isolation block
Part No. 764745
Ex barrier
ground
Hatrail
88
www.hls-austria.com
Automatic Detectors
764752
Detectors for Hazardous Areas
Housing for Ex-barrier
1
Polyester-housing for the installation of up to max. 10 Ex-barriers with integrated inside ​
mounting rail. Also for operational application under extreme environmental conditions ​
suitable.
2
1
Technical Data
Type of protection
Housing
Color
Dimensions
IP66
glass-fiber reinforced polyester
gray, similar to RAL 7000
W: 255 mm H: 250 mm D: 160 mm
3
4
Mounting material
Features
• chemically resilient
• temperature resilient
• flame retardant
• non-corrosive
• sea water resistant
• non-halogen, UV resistant
764754
5
6
Cable gland M16
7
1
Threaded cable connection for housing 764752.
Technical Data
Ambient temperature
Type of protection
Material
Color
Cable diameter
8
-20 °C ... 95 °C
IP66
Polyamide
blue, similar to RAL 9005
8 mm
9
10
11
12
13
14
15
89
Automatic Detectors
805590
Base Series IQ8Quad
Standard detector base for IQ8Quad
1
Standard IQ8Quad detector base for the series IQ8Quad. When removing the detector, the ​
loop is automatically closed. The base features a protective function against detector ​
removal, which can be used if required.
Technical Data
Features
Connection terminal
Application temperature
Storage temperature
Air humidity
Material
Color
Weight
Dimensions
Ø 0.6 mm to 2 mm²
-20 °C ... 72 °C
-25 °C ... 75 °C
< 95 % (non-condensing)
ABS
white, similar to RAL 9010
approx. 60 g
Ø: 117 mm H: 24 mm (incl. detector 62 mm)
• A lot of space for wire connection
• Automatic closing of the loop bus wiring system ​
Cable entry on the side or through the bottom plate.
• Detector extraction locking is enclosed in the base
Wago clamps for looping in wires, e.g. type 243-204 (Ø 0.5 mm - Ø 1.0 mm) or 273-104 (0.75 ​
mm² - 2.5 mm²) can be mounted on the detector base.
for detector extraction
805591
Detector base with relay contact for IQ8Quad
1
IQ8Quad detector base with relay contact output. Contact: floating NO or NC contact ​selectable via jumper. Default setting: NO contact.
Technical Data
Current consumption
Contact load relay
Connection terminal
Application temperature
Storage temperature
Air humidity
Material
Color
Weight
Dimensions
5 µA (w/o detector, active relay)
30 V DC/1 A
Ø 0.6 mm to 2 mm²
-20 °C ... 72 °C
-25 °C ... 75 °C
< 95 % (non-condensing)
ABS
white, similar to RAL 9010
approx. 80 g
Ø: 117 mm H: 24 mm (incl. detector 62 mm)
Cable entry on the side or through the bottom plate. Connection of remote indicators not ​
allowed!
Wago clamps for looping in wires, e.g. type 243-204 (Ø 0.5 mm - 1.0 mm) or 273-104 (0.75 ​
mm2 - 2.5 mm2) can be mounted on the detector base.
Not suitable for application with IQ8Quad with integrated alarm device type 802383, 802384, ​
802385 and 802386 as well as 802385.SVxx and 802386.SVxx!
90
www.hls-austria.com
Automatic Detectors
Accessories
Accessories series 9000 / 9100 / 9200
1
769803
2
Detector dismounting tool for series 9000/9100/9200
1
With the help of this special tool, detectors belonging to series 9000 / 9100 / 9200 can be ​
opened and dismounted for cleaning by authorized installation staff.
3
For ionization smoke detectors see national regulation for protection against radiation!
4
5
789855
Detector cover for detectors series 9x00 with base adapter
1
For detectors with base adapters 781497 and 781498 for protecting the detectors against ​
contamination during construction or renovation works.
6
50 pcs
7
8
789856
Detector cover for detectors series 9x00 and/or base
9
1
For detectors with base, suitable for protecting the detectors against contamination during ​
construction or renovation works.
50 pcs
10
11
12
13
14
15
91
Automatic Detectors
Accessories
Accessories series IQ8Quad
805588
Detector cover for IQ8Quad w/o built-in alarm sounder
1
The cover plate protects the IQ8Quad detector against contamination during construction ​
or renovation works.
The detector covers can only be used for IQ8Quad fire detectors without built-in alarm sounder! ​
Application only for detector types with part nos: 802171, 802271, 802371, 802374, 802375,
802473, 803371.EX, 803171.EX and 803374.EX.
50 pcs
805587
Base cover for IQ8Quad
1
The cover plate protects the IQ8Quad detector base against contamination during ​construction or renovation works.
50 pcs
805589
Detector cover for IQ8Quad with built-in alarm sounder
1
The cover plate protects the IQ8Quad detector against contamination during construction ​
or renovation works.
The detector covers can only be used for IQ8Quad fire detectors with built-in alarm sounder! ​
Application only for detector types with part nos: 802283, 802384, 802386 and 802385.
50 pcs
805571
Flush mount kit for base IQ8Quad
1
Adapter for installation in ceilings and for mounting the detector bases IQ8Quad (part nos. ​
805590 and 805591) to the bottom side of false ceilings.
Technical Data
Application temperature
Storage temperature
Type of protection
Material
Color
Weight
175 117
mm mm
140 mm
20 mm
3
mm
92
www.hls-austria.com
60
mm
45 mm
-20 °C ... 72 °C
-25 °C ... 75 °C
IP 40
ABS, plastic
white, similar to RAL 9010
approx. 165 g (with surface ring)
Automatic Detectors
805574
Accessories
1
4inch trim ring and snap-in mounting clips for IQ8Quad detector ​base
1
Snap-in mounting clips and trim ring for base installation, e.g. for installation on 4” elec­
trical boxes.
2
Technical Data
Material
Color
Dimensions
ABS plastic
white, similar to RAL 9010
Ø: 155 mm H: 19 mm (outside)
3
1 x trim ring and 2 x snap-in mounting clips
4
5
6
Application example
805576
7
Label plate for detector base IQ8Quad
1
8
Before or after the installation of the detector, the label plate can be inserted at the side slot ​
of the IQ8Quad detector base.
For identification purposes the detector can be provided with the detector address and detector ​
zone for ceilings with a maximum height of 3 m.
9
A label can be attached to the inscription field. Blank labels can be marked when using a PC, e.g. ​
SIGEL part no. LP725-white (58 x 18 mm) or other suppliers of writing materials.
10
There is a help file in the download area for creating the printing material.
Applicable for base 805590/91 with 805570; for 805593.10, 805594.10.
Not to be used for base 805590/91 in combination with 805571, 805572, 805573, 805574.
11
10 pcs
12
13
14
Application example
15
93
Automatic Detectors
805577
Accessories
Mounting adapter for intermediate ceilings
1
The mounting adapter is used for the quick and secure attachment of bases of the IQ8Quad ​
detector series, 9x00, IQ8Alarm & alarm signaling devices, parallel detector indicators, etc. ​
to suspended ceiling systems. It saves the usage of special hollow cavity fasteners, since ​
the mounting screws of the bases are screwed directly into the slots of the mounting ​
adapter. The mounting adapter offers additional advantages in the fixing of the cables, ​
rigid/flexible cable inlays and threaded cable connections.
Technical Data
Material
ABS
10 pieces
Dimensions in mm
39,0
2,8 31,0
44,0
49,0
10,0
40,0
23,0
99,0
21,5
Application examples for fixing of the cables, rigid/flexible cable inlays and threaded cable connections
767800
Mounting bracket for lintel installation
1
Mounting bracket for all bases/detectors of the IQ8Quad group, series 9x00, RAS 2103 and ​
for IQ8Alarm & all alarm devices.
The distance between the mounting holes is 6 cm and the diameter is approx. 5 mm.
Technical Data
Material
Color
aluminum
white, similar to RAL 9010
Mounting bracket and installation material
805570
IP43 protection for detector base IQ8Quad, flat design
1
For installation in environments with dust and humidity. The IP protection protects the ​
IQ8Quad detector base against dust and humidity. It increases the protection level to IP 43. ​
For easy mounting to the base, the IP protection is provided with an adhesive film.
Technical Data
Type of protection
Material
Color
10 pcs
94
www.hls-austria.com
IP43
SBR/NR
white, similar to RAL 9010
Automatic Detectors
805573
Accessories
1
IP43 protection for IQ8Quad detector bases, deep design
1
As 805570 but as universal protection. Additionally, the seal prevents humidity from ​entering at the sides.
2
Technical Data
Type of protection
Material
Color
IP43
rubber
white, similar to RAL 9010
3
5 pcs
4
805572
IP43 moisture-proof surface-mounted base adapter for IQ8Quad ​detector base
5
1
The damp location base adapter was specifically designed for surface mount installation by ​
means of cable conduits. The adapter is provided with three 20 mm (diameter) cable ​
entries.
6
The built-in seal protects the adapter against condensed water.
Technical Data
Type of protection
Material
Color
IP43
PC
white, similar to RAL 9010
7
3 x screw connections are included
58,5
58,5
8
43,6
29,8
40,0
43,6
9
2,6
2,0
17,0
10
20,0
145,0
11
117,0
6,0
12
6,0
60,0
3,0 ø
15,5
117,0
8,4
6,4
13
17,8
115,0
5,5 ø
26,0
26,0
14
2,0
15
16,0
Dimension drawing
95
Automatic Detectors
781482
Accessories
Kit for suspended installation
1
Kit for detector bases 781590, 805590, 805591 and 801593 for suspended installation ​
with pendulum stabilizer, cable entry at the top, pull relief by means of PG cable entry ​
including junction box with terminals. The detector height can be adjusted individually ​
depending on the cable length to bridge over the heat cushion below the ceiling.
Technical Data
Material
Installation
Color
Dimensions
ABS plastic
attached to the zone cable
white, similar to RAL 9010
Ø: 84 mm H: 15 mm (aluminum-stabilizer)
It is not possible to use telescopic rods.
Not suitable for Series 3000.
as shown
Heat cushion: Smoke-free area
Filled with smoke:
Detection guaranteed
6-pole terminal
inside
Cable entry with cord grip
Detector base can be equipped with
IP protection 805570 or 805573
96
www.hls-austria.com
Standard detector cable
Gap between screws suitable
for detector series
78xxxx and 80xxxx
Automatic Detectors
781550
Accessories
Protective cage
1
Protective cage for detectors
Steel basket for protection from damage and also unauthorized disconnection of the ​
detector.
2
1
Technical Data
Material
Color
Dimensions
steel with paint coating
white, similar to RAL 9010
Ø: 140 mm H: 115 mm
3
Can be used with all bases, IP43 moisture-proof adapter, also for wireless base and wireless ​
gateway.
4
5
6
7
8
9
Application example with IQ8Wireless detector base and IQ8Alarm
805560
10
EMC shield for IQ8Quad detector base
1
In fire alarm systems where a high electromagnetic interference/EMI load (e.g. by fluores­
cent lamps or electrical control devices) must be expected it is recommended to mount the ​
EMI-Module in the standard detector base (Part no. 805590) of the corresponding fire ​
alarm detectors.
11
The EMI-Module must only be operated in conjunction with standard IQ8Quad detector base ​
(without relay board) and only for detectors without integrated alarm devices (part no. 802382 ​
to 802386, incl. adapted variants).
12
10 pcs
13
14
15
850054
Special painting IQ8Quad detector base
The IQ8 detector base is painted and delivered according to the required RAL color.
For identical colors, we suggest to order a suitable number for serial purposes.
​
When ordering please specify:
- RAL code
- Glossy, semi-matt, matt finishing
850055
Special painting IQ8Quad
As 850084 but for automatic detectors of the IQ8Quad series.
97
Automatic Detectors
Accessories
Accessories for Several Detector Series
805580
Detector removal tool
1
It is suitable for removing Series 9x00 as well as IQ8Quad detectors. Through optional ​
adaptation of the suction cup in the respective insertion on the detector removal tool, the ​
IQ8Quad detector covers (Part Nos. 805588 + 805589) and the base covers for IQ8Quad ​
(Part No. 805587) can be attached as well as removed. The detector removal tool can be ​
adapted to the telescope rod part no. 060426 and 060427 as well as with 805581 to ​
769813.
Snap on detector removal tool, then spin clockwise and remove the detector.
Application example
805581
Adapter for Esser pole (part no. 769813)
1
The adapter for the 769813 pole is designed for attaching the 805580 detector removal ​
tool and the 805582 smoke detector tester.
060427
Plastic telescopic rod
1
Extendable detector pull-down pole made of glass-fiber reinforced plastic for adapting the ​
805580 detector removal tool as well as testers with part nos. 060429 and 805582.
Technical Data
Material
Length
Features
• Length of 1.26m in retracted state
• 4 segments, lockable
98
www.hls-austria.com
Fiberglass
4.5 m
Automatic Detectors
060426
Accessories
Plastic telescopic extension
1
Telescopic extension for plastic telescopic rod (part no. 060427). Up to 3 telescopic exten­
sions can be attached to the telescopic rod. The maximum height that can be reached is ​
increased to 9 m.
2
1
Technical Data
Material
Length
Fiberglass
1.13 m
3
4
Features
• Easy aid for daily maintenance of high ceilings
• Stable construction
• Important for attaching and releasing detectors
• Extremely high level of flexural strength due to ​
5
fiber-plastic composite material
6
• Totalock TM for easy and secure locking
805586
Carrying bag for test equipment including cover for telescopic ​rods
7
The carrying bag has many pockets and compartments in which the ESSER smoke alarm ​
testers, test gas bottles, all cables and other maintenance accessories can be stored. So ​
everything you need for maintenance can always be found in one place. The upholstered, ​
adjustable shoulder strap ensures very easy and comfortable transport. An additional ​
advantage: the bag protects equipment from dirt and moisture.
8
Technical Data
9
1
Dimensions
W: 480 mm H: 420 mm D: 260 mm (carrying bag)
1 x carrying bag and 1 x cover for telescopic rods/extensions
10
Features
• Exterior lid with Velcro fastening transportation ​
straps for telescopic rod and extensions
11
• Inside lid with 2 storage compartments for battery ​
•
•
•
•
backs 060431
Inside compartment with up to three optional ​dividers
Big front pocket, with up to two optional dividers
Wide shoulder strap with sliding shoulder pad and ​
additional handles
Cover with carrying strap for up to 4 telescopic ​
rods 060427 and/or extensions 060426
12
Capacity of the
protective
carrying bag:
2 x battery baton
13
1 x telescopic rod
14
3 x smoke detector tester
15
Front pocket for charger,
test gas, etc.
Up to 4 telescopic rods
in a special cover
Capacity of the transport bag
99
Automatic Detectors
805551
Accessories
Multi-stimulus detector tester
1
Features
• Generation of smoke, heat and CO in a single test ​
unit
• Clearing cycle of the detector via integrated ventil­
ator for better reset
• Simultaneous or sequential testing with various ​
stimuli
• Suitable for single and multi-criteria detectors
• Suitable for smoke-, heat- and gas- (CO) ​detectors
• Targeted heat rays provide fast activation of heat ​
•
•
•
•
•
sensors (up to 90°C/194°F, and/or adjustable up ​
to 100°C/212°F)
Test activation via infrared barrier, no mechanical ​
triggering, no ceiling contact necessary
Easy, fast and efficient testing, as changing of ​
testing device is not necessary
Multilingual and user-friendly menu control
Battery operated portable device
Environmentally friendly and safe through usage ​
of test cartridges instead of test gas cans
Detector tester kit Testifire 2001 for the functional testing of point-type fire detectors with ​
various sensors. The activating stimuli for smoke, heat and CO (carbon monoxide) are ​
generated in this testing unit. Thus the changing of test tools for different types of ​detectors is no longer necessary.
All fire detector types can be tested with only one test instrument. The test tool is suitable ​
for all optical smoke detectors, ionization detectors, CO detectors and heat detectors. It ​
facilitates fast and effective testing of single and intelligent multi-sensor detectors. So ​
testing of the different sensors can be carried out one after another or for all at the same ​
time.
The required stimuli are generated on demand at the time of test from the corresponding ​
capsule (smoke or CO). Pressurized gas cans are no longer being used.
The selection of the testing stimuli, as well as their combination and sequence are menu ​
driven via keypad and are represented on the display (multilingual). So e.g. simultaneous ​
or sequential testing, or also a combination thereof, can be easily programmed and then ​
carried out at the detector. The activation of the testing device occurs automatically, as ​
soon as the detector interrupts the light barrier integrated in the device. If necessary, a ​
clearing phase can be chosen between the respective testing criteria that enables the ​
stimuli to be blown out of the detector immediately for the next test by the integrated vent­
ilator.
The respectively active criterion is represented by a multi-coloured LED indicator and is ​
clearly recognizable even from large distances. The fill-level of the respective test r​ esources
capsules can be shown in the display. Warnings are indicated automatically e.g. i​f a
​ ith
capsule is nearly empty. The capsules offer much higher test capacities in comparison w
aerosol cans.
The power supply of the testing head occurs via Ni-MH batteries (metal hydride batteries) ​
in the adapter between testing head and telescopic rod. Charging of the battery occurs with ​
the charger optionally via adapter (100-230 V AC) or via 12 V DC input (vehicle cigarette ​
lighter).
Suitable for IQ8Quad and 9x00 detector series.
Technical Data
Battery charging
Heat detector response threshold
Ambient temperature
Storage temperature
Air humidity
75-90 minutes
up to 90°C adjustable up to 100°C
5 °C ... 45 °C
-10 °C ... 50 °C
< 85 % (non-condensing)
Detector tester kit Testifire 2001 consists of:
Testing head, smoke capsule, CO capsule, 2 Ni-MH battery packs, charger
Accessories
805552
805553
060426
060427
060431
Smoke capsule for Multi-stimulus detector tester 805550/51
CO capsule for Multi-stimulus detector tester 805551 (Testifire TC3)
Plastic telescopic extension
Plastic telescopic rod
Spare battery baton
Selection of different test criteria displayed
100
www.hls-austria.com
Automatic Detectors
805550
Accessories
1
Multi-stimulus detector tester TF1001
1
Detector tester Testfire 1001 as 805551, but for testing of detectors with smoke and heat ​
sensors.
2
Technical Data
Battery charging
Heat detector response threshold
Application temperature
Storage temperature
Air humidity
Features
• Creation of smoke and heat with one single test ​
•
•
•
•
•
•
•
•
•
•
device
Desmoking of detector via an integrated fan for ​
fast resetting
Simultaneous or successive testing with different ​
activating materials
Suitable for single criterion and multi-criterion ​
detectors
Suitable for smoke and heat detectors
Targeted heat radiation facilitates quick activation ​
of the thermal sensors (up to 90°C/194°F and/or ​
can be switched up to 100°C/212°F)
Test activation through infrared barrier, no mech­
anical triggering, ceiling contact not necessary
Quick, easy and efficient testing since there is no ​
need to exchange test device
Multilingual and user-friendly menu
Portable battery-powered device
Environmentally friendly and safe through usage ​
of test cartridges instead of test gas cans
75-90 minutes
up to 90°C adjustable up to 100°C
5 °C ... 45 °C
-10 °C ... 50 °C
< 90 % (non-condensing)
3
Detector tester kit Testifire 1001 consists of:
Testing head, smoke capsule, 2 Ni-MH battery packs, charger
4
Accessories
805552
060426
060427
060431
Smoke capsule for Multi-stimulus detector tester 805550/51
Plastic telescopic extension
Plastic telescopic rod
Spare battery baton
5
6
Smoke
Heat
CO
Menu
Status
Example of testing
with only one stimuli
Smoke 1
Heat 2
CO 3
Menu
Status
Example of sequential
testing (all criteria
successively)
Smoke 1
Heat 1
CO
Menu
7
Status
Example of a
simultaneous testing
(smoke + heat at the
same time)
8
Smoke 1
Heat 1
CO 2
Menu
9
Status
Example of
combination of
simultaneous and
sequential testing)
10
11
Selection of different test criteria displayed
805552
Smoke capsule for multi-stimulus detector tester 805550/51
12
1
Replacement smoke capsule (Testifire TS3) for the testing of smoke detectors series ​
IQ8Quad and 9x00 with optical and/or ionization sensors. Suitable for the multi-stimulus ​
detector tester 805550/51.
13
14
Features
15
• Non-flammable, non-toxic materials
• Production of test gas only during the testing
• Does not cause any residue in the sensor ​
chamber
• Suitable for optical and ionization detectors
• No test gas storage under pressure – no ​dangerous goods
• More productivity than the spray can
101
Automatic Detectors
805553
Accessories
CO capsule for multi-stimulus detector tester 805551
1
Replacement CO capsule (Testifire TC3) for the testing of detectors with carbon monoxide ​
sensors (CO). Especially suited for the IQ8Quad OTG multisensor detector 802473 (with ​
CO sensor). Suitable for the multi-stimulus detector tester 805551.
The IQ8Quad OTG multisensor detector (CO) 802473 is generally tested either
-with the test gas 060430.10, suitable for the smoke detector tester 805582, or
-with 805552, suitable for the multi-stimulus detector tester 805551.
Features
The 802473 is VdS-approved as a smoke detector, the CO test gas is required for the additional ​
triggering of the electrochemical CO gas cell.
• Non-flammable CO activating material
• Generation of small amounts of CO
• Generation of CO during testing only
• No storing of pressurized CO - no dangerous ​
goods
• More productivity than the spray can
805582
Smoke detector tester
1
The smoke detector tester is designed for electric function control for the IQ8Quad and ​
series 9x00 detectors. After an aerosol has been released, the operation capacity of the ​
measuring chamber can be tested by using the transceiver. The smoke detector tester is ​
adapted to the rod (Part No. 060427).
The telescopic rod is not supplied as standard.
Accessories
060426 Plasitc telescopic extension
060427 Plastic telescopic rod
060430.10
Test gas for smoke detecetor tester 805582
1
For IQ8Quad and series 9x00 detectors, suitable for smoke detector tester 805582.
Technical Data
Content
250 ml (per bottle)
Not suitable for Series 9000, 9100 and 9200 ionization smoke detectors.
Please take note that this item has to be handled as dangerous goods (aerosols, non-flammable, ​
UN1950)
805583
CO test gas for smoke detector tester 805582
1
Test gas for testing carbon monoxide CO-detectors. Specifically designed for the OTG ​
multisensor (CO) IQ8Quad 802473, suitable for smoke detector tester 805582.
Technical Data
Content
250 ml (per bottle)
The OTG multisensor detector (CO) IQ8Quad (part no. 802473) should only be tested in ​connection with test gas 060430.10 suitable for smoke detector tester 805582. Detector 802473 ​has
been approved as smoke detector by VdS and the CO test gas is used to additionally trigger t​he
electrochemical CO-gas cell.
Please take note that this item has to be handled as dangerous goods (aerosols, non-flammable, ​
UN1950)
102
www.hls-austria.com
Automatic Detectors
060429
Accessories
1
Test head for heat detector together with battery and charger
1
Technical Data
Battery charging
Ambient temperature
Storage temperature
Air humidity
75-90 minutes (if completely discharged)
5 °C ... 45 °C
-10 °C ... 50 °C
< 85 % (non-condensing)
2
3
Test head, 2 battery batons, charger
Accessories
Features
060426 Telescopic extension
060427 Plastic telescopic rod
060431 Spare battery baton
4
• Mains cable is not required for testing
• Power supply with rechargeable NiMH battery in ​
•
•
•
•
•
•
•
5
the adapter of the telescopic rod
Time based termination of testing after 120 ​
seconds in order to prevent any heat-related ​
damages of the detectors
Detector head is switched off after not being used ​
for 5 minutes
Adjustable inclination angle of detector head for ​
an optimal orientation towards the object which ​
has to be tested
Testing height up to 6 meters with telescopic rod ​
and up to 9 meters with its extension device
Excess-current protection for the battery
Display of operating status of the detector head ​
with Duo-LED (red/green)
Battery can be charged via mains supply or via ​
cigarette lighter in vehicles
060431
6
7
8
9
Spare battery baton
1
10
Replacement battery pack (NiMH) for Test Head 060429 and 805551.
11
12
769870.20
Smoke detector tester
13
1
Smoke detector tester allows fast and reliable functionality testing for Series IQ8Quad and ​
9x00 smoke detectors. Through reduced mechanically controlled actuation pressure, ​
suspended installed detectors can also be tested. Control electronics guarantee a defined ​
spray impulse. Spray can and batteries can be easily replaced.
14
Technical Data
Operating voltage
Testing capacity
2 x 9 V batteries
approx. 2000 applications / can
15
Telescopic rod 769813 is required.
Substitute for 769870.10!
1 x test gas 769070
2 x 9V batteries 018051
1 x bellows for IQ8Quad and 9x00
Accessories
769070 Test gas
018051 9V battery
103
Automatic Detectors
769871.20
Accessories
Conversion kit for smoke detector tester 769870
1
The conversion kit (part no. 769871.20) is used to convert the smoke detector tester (part ​
no. 769870 and 769870.10) to test the functions of IQ8Quad and 9x00 smoke detectors.
The conversion kit includes special contact fields to test smoke detectors and the associ­
ated expansion bellows.
Substitute for 769871!
1 x bellows for Series IQ8Quad and Series 9x00
1 x contact spring
3 x fixing screws
769070
Test gas for smoke detector testers 769870.10 and 769870
1
For series 9x00 and IQ8Quad detectors.
Technical Data
Content
150 ml (per bottle)
CFC-free test gas, suitable for approx. 2000 applications.
Please take note that this item has to be handled as dangerous goods (aerosols, flammable, ​
UN1950).
769813
Telescopic rod
1
For smoke detector tester 769870.20 (length 3.75 m, three pieces, locking devices).
Technical Data
Length
769814
3.75 m
Extension pole
1
For smoke detector tester 769870.20, detector removal tool 769804 and telescopic rod ​
769813 (length 4 m, two pieces, locking devices).
Technical Data
Length
769080
4m
Smoke pellets for testing purposes
1
Pellets for the generation of dense bright smoke. To charge detectors with smoke for ​
testing purposes and verification of air flow. The pellets are lit with an open flame (e.g. ​
matches, lighter etc.). Extinguishing is not necessary. Please ensure the use of a non-​flammable base. After ignition the pellet will burn to complete ash (without formation of ​
flames).
Without oil
6 pcs. smoke pellets
Features
• 40 sec. burning-time per smoke pellet
• 18 m³ smoke produced per smoke pellet
104
www.hls-austria.com
1
2
3
4
5
6
7
8
9
10
Manual Call Points
Large Design - ABS
106-109
Large Design - Aluminum
110-112
Large Design - Accessories
113-116
Special Design
117-120
11
12
13
14
15
105
Manual Call Points
Large Design - ABS
1
133
36
133
Features
• Slimline design
• Plug-in connection clamps
• Optional terminal clamps
• 2 x cable entries on top, at the bottom and on the ​
rear panel
• Fixing on standard flush mounted installation box
• Test function via manual call point service key
• Detectors that are not ready for operation can be ​
marked with the "out of order" label by reversing ​
the enclosed operating front foil
The advanced generation of manual call points with fragile elements meets the latest multi­
cultural requirements of the EN 54 - 11 standards as type B (double action). The elegant ​
detector housing, available in 5 different RAL colors, is provided with a pictogram, which is ​
easy to comprehend for foreign people, illiterates as well as children.
Depending on individual requirements, optional labeling foils can be used which can easily ​
replace the pictogram without special tools. The triggering element is protected by a pane ​
of glass and is indicated by arrows.
If required, optional labeling foils can be used, which can easily replace the pictogram. The ​
triggering element is protected by a glass pane and is indicated by arrows. The innovative ​
manual call points can be tested by using the service key to activate the triggering mech­
anism, which is hidden by a faceplate. Clever design structures allow easy installation.
The manual call points consist of a housing and an electronic module, each of the two ​
parts must be ordered separately.
Type B definition - double action in accordance with EN 54-11 § 3.4.2
(excerpt taken from EN standard):
Manual fire alarm unit, for which the alarm status cannot be set until an alarm is additionally ​
triggered by the user after the fragile element has been broken or its position has been changed.
Take note, for a LARGE MCP you have to order the electronic module and the MCP housing ​
separately to have a complete MCP.
Not all possible combinations of electronic modules and housings are approved by VdS. When ​
using the manual call point as a fire detector for manual actuation in compliance with the EN 54-​
11 standards, a red housing together with the provided pictogram must be used. When using ​
the manual call point in heat exhaust or extinguishing system areas, the appropriate housing ​
color must be chosen in compliance with the correct standards.
Wago clamps for looping in wires, e.g. type 273-100 (0.5 mm² - 1.5 mm²) or 273-104 ​
(0.75 mm² - 2.5 mm²) can be mounted inside the MCP.
MCP out of order
Application example
106
www.hls-austria.com
Easy to maintain the change of condition
by turning the operating foil
MCP ready for use
Manual Call Points
Large Design - ABS
1
Plastic Housing - Large Design
1
Housing for electronic module 80490x.
2
Technical Data
Type of protection
Housing
Installation
Weight
Dimensions
IP44
ASA plastic
surface mount
approx. 83 g (w/o electronic module)
W: 133 mm H: 133 mm D: 36 mm
3
Housing with glass pane (704910)
Plastic key (769910)
4
Accessories
704910
769910
769911
769916
704917
704911
704900
Spare glass for manual call points
Plastic spare key
Metal key for large MCP
Service key
Option IP55 shrink sleeve for large MCP 80490x
Universal foil for large MCP housing ABS
5
6
Housing with glass pane, red, similar to RAL 3020
7
Technical Data
Dimensions
W: 133 mm H: 133 mm D: 36 mm
8
The red manual call point housing is only available with the pictogram (as shown) in compliance ​
with EN 54-11.
Please note that in compliance with EN54-11 the labeling must come with the burning house ​
symbol.
Pictogram according to EN54-11
704901
9
Pictogram according to EN 54-11
10
Housing with glass pane, blue, similar to RAL 5015
The 804902 electronic module in a blue housing complies with the EN 12094-3 and thus can be ​
applied as an electronic stop button for gas extinguishing systems in dry, non-hazardous ​
production sites.
For different use such as application as "HOUSE ALARM" push button, ready-made labels are ​
provided.
11
12
Labeling foil set (white) for various international applications.
704902
Housing with glass pane, yellow, similar to RAL 1021
13
The 804900 or 804901 electronic module in a yellow housing 704902 complies with the EN ​
12094-3 and thus can be applied as electronic control module for gas extinguishing systems in ​
dry, non-hazardous production sites.
For different use such as application as "HOUSE ALARM" push button, ready-made labels are ​
available.
14
Labeling foil set (black) for various international applications.
704903
15
Housing with glass pane, orange, similar to RAL 2011
Labeling foil set (black) for various international applications.
704904
Housing with glass pane, green, similar to RAL 6002
Labeling foil set (white) for various international applications.
107
Manual Call Points
Large Design - ABS
Electronic Modules Standard
1
Technical Data
Operating voltage
Alarm current @ 9 V DC
No. of detector/zone
Alarm display
Connection terminal
Application temperature
Storage temperature
Type of protection
Housing
Weight
Detector specification
Dimensions
804900
8 ... 30 V DC
typ. 9 mA
10 detectors per zone (according to VdS)
LED, red
max. 2,5 mm² (AWG 26-14)
-20 °C ... 70 °C
-30 °C ... 75 °C
IP 44 (in housing), IP 55 (with accessory)
PC ASA plastic
approx. 236 g (with housing)
EN 54-11, Type B
W: 133 mm H: 133 mm D: 36 mm
Conventional MCP electronic module
1
Approval: VdS, CNBOP
With alarm indicator, suitable for connection to a standard detector zone.
In combination with the yellow housing (part no. 704902), the electronic module is approved as ​
an electronic control unit for gas extinguishing systems.
The 804900 electronic module with yellow housing conforms to the EN 12094-3 standard and ​
can be used as an electronic control unit for gas extinguishing systems in dry, non-hazardous ​
industrial premises.
CNBOP certificate valid only with additional "Pozar" sign available as option (part no. 704911).
804901
Conventional MCP electronic module with second microswitch
1
Approval: VdS, CNBOP
As 804900, but with second and potential-free switch contact.
Technical Data
Contact load
30 V DC / 1 A
In combination with the yellow housing (part no. 704902), the electronic module is approved as ​
an electronic control unit for gas extinguishing systems.
The 804901 electronic module with yellow housing conforms to the EN 12094-3 standard and ​
can be used as an electronic control unit for gas extinguishing systems in dry, non-hazardous ​
industrial premises.
CNBOP certificate valid only with additional "Pozar" sign available as option (part no. 704911).
804902
Conventional MCP electronic module w/o snap-on function
1
Approval: VdS with blue housing 704901
As 804900, but without snap-on function.
This electronic module is only approved as an electric stop push-button for gas extinguishing ​
systems when combined with the blue housing (part no. 704901). The electronic module ​
804902 with blue housing complies with the EN 12094-3 standard and therefore it can be used ​
as an electric stop push-button for gas extinguishing systems in dry, non-hazardous branches.
In case the manual call point is used as a "house alarm" push-button, pre-printed labels are ​
provided in the manual call point package.
108
www.hls-austria.com
Manual Call Points
Large Design - ABS
1
Electronic Modules IQ8MCP
1
Technical Data
Operating voltage
Quiescent current @ 19 V DC
Alarm current w/o communication curtain
No. of detector/zone
Operation indicator
Alarm display
Connection terminal
Application temperature
Storage temperature
Type of protection
Housing
Weight
Detector specification
Dimensions
804905
2
8 ... 42 V DC
approx. 45 μA
approx. 18 mA
10 detectors per zone, 127 detectors/loop (according to ​
VdS)
LED, green
LED, red
max. 2.5 mm² (AWG 26-14)
-20 °C ... 70 °C
-30 °C ... 75 °C
IP 44 (in housing), IP 55 (with accessory)
PC ASA plastic
approx. 236 g (in housing)
pr EN 54-11, type B
W: 133 mm H: 133 mm D: 36 mm
3
4
5
IQ8MCP electronic module
6
1
Approval: VdS, CNBOP
Addressable electronic module suitable for use in the esserbus and powered loop with ​
alarm latch and alarm indicator. Optional connection for conventional MCP. Without BUS ​
connection, the detector operates as conventional MCP. Built-in loop isolator in the manual ​
call point.
804906
7
CNBOP certificate valid only with additional "Pozar" sign available as option (part no. 704911).
8
IQ8MCP electronic module w/o isolator but with relay
9
1
Approval: VdS, CNBOP
10
Addressable electronic module with relay, suitable for use in the esserbus and powered ​
loop with alarm latch and alarm indicator. Without BUS connection, the detector operates ​
as conventional MCP.
Without built-in loop isolator and optional connection for conventional MCP.
11
The relay output is activated with the triggering of this detector. The relay output can be ​
programmed in the System 8000 and IQ8Control fire alarm control panel customer data as ​
a control group with freely programmable trigger functions.
12
CNBOP certificate valid only with additional "Pozar" sign available as option (part no. 704911).
13
Technical Data
Contact load relay
30 V DC / 1 A
14
15
109
Manual Call Points
Large Design - Aluminum
Both housing and electronic module need to be ordered. Not all possible combinations of ​electronic modules and housings are approved by VdS. The approved combinations are listed in ​the
VdS approval field for the corresponding electronic module.
Electronic Module Series 9000
704477.10
MCP electronic module Series 9000 with second micro-switch
1
Approval: VdS with housing 704801.10
printed with pictograms in accordance with EN 54-11
Technical Data
Operating voltage
Alarm current @ 9 V DC
Contact load
No. of detector/zone
Alarm display
Connection terminal
Application temperature
Storage temperature
Type of protection
Weight
Detector specification
Dimensions
8 ... 30 V DC
typ. 9 mA
30 V DC/1A
10 detectors per zone (according to VdS)
LED, red
0,6 ... 1,5 mm²
-20 °C ... 70 °C
-30 °C ... 75 °C
IP 43 (with housing)
IP 54 (with housing and option 704070)
approx. 100 g (w/o housing)
EN 54-11, type B
W: 95 mm H: 95 mm D: 25 mm
Electronic Module Series 9200
804473.10
MCP electronic module Series 9200 with zone isolator
1
Approval: VdS with housing 704801.10
Printed with pictograms in accordance with EN 54-11
Technical Data
Operating voltage
Quiescent current @ 19 V DC
Alarm current @ 9 V DC
Alarm current w/o communication curtain
Contact load
No. of detector/zone
Alarm display
Connection terminal
Application temperature
Storage temperature
Type of protection
Weight
Detector specification
Dimensions
110
www.hls-austria.com
8 ... 42 V DC
approx. 45 μA
typ. 9 mA
approx. 18 mA
30 V DC/1A
10/zone, 127/loop (VdS)
LED, red
0,6 ... 1,5 mm²
-20 °C ... 70 °C
-30 °C ... 75 °C
IP 43 (with housing)
IP 54 (with housing and option 704070)
approx. 100 g (w/o housing)
EN 54-11, type B
W: 95 mm H: 95 mm D: 25 mm
Manual Call Points
Large Design - Aluminum
1
Aluminium Die-Cast Housings
1
Technical Data
Type of protection
Material
Installation
Weight
Dimensions
2
IP43, IP54 with kit 704070
aluminum, die-cast
surface mount
approx. 600 g
W: 126 mm H: 126 mm D: 42 mm
3
red = similar to RAL 3000; blue = similar to RAL 5009; yellow = similar to RAL 1018
Key: 769910, 769911 (accessory)
4
Housing with glass pane and plastic key, fixing material, 1 x multilingual "out of order" paper ​
insert, 2 x cable entries, 2 x dummy plugs
704801.10
5
Housing with glass, red, in compliance with EN 54-11
1
Printed with pictograms in accordance with EN 54-11.
6
Technical Data
Color
red, similar to RAL 3000
7
8
704804
MCP housing with glass, red, printed: house alarm-ESSER
Technical Data
Color
704854
9
red, similar to RAL 3000
MCP housing with glass, blue, printed: house alarm-ESSER
10
Technical Data
Color
blue, similar to RAL 5009
11
704874
MCP housing with glass, yellow, printed: house alarm-ESSER
Technical Data
Color
12
yellow, similar to RAL 1018
13
14
15
111
Manual Call Points
Large Design - Aluminum
MCP - Housing Neutral Version without Printed Pictogramm
1
704800
MCP housing aluminum, red, neutral
1
Technical Data
Color
704850
red, similar to RAL 3000
MCP housing aluminum, blue, neutral
1
Technical Data
Color
704870
blue, similar to RAL 5009
MCP housing aluminum, yellow, neutral
1
Technical Data
Color
704890
yellow, similar to RAL 1018
MCP housing aluminum, gray, neutral
1
Technical Data
Color
112
www.hls-austria.com
gray, similar to RAL 7035
Manual Call Points
704910
Large Design - Accessories
1
Spare glass pane for MCP housings 70490x, 7048xx and 761694
1
Spare glass pane for detector housings large design 70490x, 7048xx, 761694 and 761697 ​
in compliance with EN 54-11.
2
Technical Data
Dimensions
W: 80 mm H: 80 mm
3
10 pcs
4
701040
Spare glass pane red for MCP housings 7047xx and 7048xx
1
Spare glass pane, printed with red circle segments (similar to RAL 3000) for all 7047xx ​
and 7048xx manual call points (large design).
5
Technical Data
Dimensions
W: 80 mm H: 80 mm
6
10 multilingual "out of order" paper labels are included.
10 pcs
769921
7
"Out of order" sign for large MCP, multilingual
8
1
Plastic sign for all 7047xx, 7048xx and 70490x manual call points (large design).
Technical Data
Dimensions
9
W: 80 mm H: 80 mm
10
704915
11
Operating panel foil for large manual call point 80490x, neutral
1
Replacement operating panel foil, neutral without logo, for large design 80490x manual call​
points in resistant plastic design. The foil is designed as a double-sided insert. Comple­
menting the standards-compliant symbolism for manual fire alarms according to EN 54-11 ​
(type B), it contains a symbol on the back for the removal from service of the alarm and is ​
easily accessible at all times for possible maintenance operations.The out-of-order repres­
entation occurs via an internationally understandable construction worker symbol and ​
multilingual text.
12
13
Technical Data
Material
Dimensions
PP (0.3 mm)
W: 72 mm H: 75.7 mm
14
10 pcs.
15
MCP “Out of Order”
Easy to maintain the change of condition
by turning the operating foil.
MCP ready for use
Application example
113
Manual Call Points
704917
Large Design - Accessories
Option IP55 shrink sleeve for large MCP 80490x
1
10 shrink sleeves for clamp terminals to increase protection class to IP55.
10 pcs
IP44
IP55
Application example without (IP44) and with (IP55) shrink sleeve
704911
Foil for front face with universal text for large MCP ABS 70490x
1
Universal, punched foil set (transparent with white imprint) for the labeling field, different ​
from the standard version.
Transparent foil with white lettering.
10 pcs
704912
Foil for front face with universal text for large MCP ABS, black ​lettering
1
As 704911, but with black imprint.
10 pcs
704070
IP54 kit for large manual call points 7048xx
1
Cable entries to increase protection class from IP 43 to IP 54 for manual call points in die-​
cast aluminium housings (7048xx).
Technical Data
Material
Color
Cable diameter
as shown
114
www.hls-austria.com
PS
gray, similar to RAL 7035
6 mm
Manual Call Points
769910
Large Design - Accessories
1
Plastic key for large MCP
1
Plastic key type D for all manual call points (large design).
2
Please note that for activating the test functionality of electronic modules (part no. 80490x), the ​
service key 769916 is required.
3
4
769911
Metal key for large MCP
1
Metal key type D for all detector housings (large design).
5
Please note that for activating the test functionality of electronic modules (part no. 80490x), the ​
service key 769916 is required.
6
7
769916
Service key for electronic module (part no. 80490x)
8
1
With this metal service key, the test functionality of the manual call point is activated and ​
reset by authorized persons only.
The key is suitable for all electronic modules with part nos. 80490x from index 05 and ​
yellow locking.
9
10
781682
11
Weather protective cover for MCP housings 7047/48xx, red
1
Protective housing with protruding roof edge, for all 7047xx and 7048xx detector housings ​
for increased mechanical protection as well as for protection from bad weather conditions.
12
Technical Data
Material
Color
Dimensions
PVC
red, similar to RAL 3000
W: 135 mm H: 153 mm D: 62 mm
13
Please mention for the manual call point, large design plastic (e.g. IQ8MCP), the protection ​
cover part no. 781693 and the related accessories.
14
Weather protective cover and mounting material
781692
Weather protective cover for MCP housings 7047/48xx, blue
15
1
Protective cover similar to 781682.
Technical Data
Color
blue, similar to RAL 5009
Weather protective cover and mounting material
115
Manual Call Points
781693
Large Design - Accessories
Protective cover for manual call points, German
1
Technical Data
Ambient temperature
Type of protection
Material
Weight
Dimensions
-40 °C ... 49 °C
IP 44
Polycarbonate
approx. 590 g
W: 180 mm H: 260 mm D: 100 mm
This protective cover prevents false alarms, without hampering real alarms. This device consists ​
of a rack and a lid, made of transparent polycarbonate.
It prevents inadvertent activation, vandalism, dust and water from triggering false alarms. The ​
protective cover is suitable for all manual call points.
Features
Accessory for installation
• Easy to install
Application example
781694
Protective cover for manual call points, English
As 781693, but ESSER-English:
781698
Surface spacer for protective cover
1
The spacer is required for surface mount wiring.
Technical Data
Weight
Dimensions
approx. 510 g
W: 180 mm H: 260 mm D: 50 mm
Accessory for installation
781699
IP55 kit for protective cover
1
Mounting kit - self-adhesive sealing kit for protective cover (781693, 781694) and an ​
increased protection level from IP 44 to IP 55.
781699
781698
78169x
Application example
116
www.hls-austria.com
Manual Call Points
761694
Special Design
Addressable manual call point, IP66
1
Addressable manual call point in conformity with EN 54-11 Type B with loop isolator for ​
manually triggering fire alarms or hazard alarms. For outdoor application or application in ​
damp environments.
2
1
Technical Data
Operating voltage
Quiescent current @ 19 V DC
No. of detector/zone
Alarm display
Connection terminal
Application temperature
Storage temperature
Type of protection
Housing
Color
Weight
Dimensions
8 ... 42 V DC
approx. 45 μA
max. 10 (according to VdS), 127 / loop
LED, red
max. 1,5 mm²
-20 °C ... 70 °C
-25 °C ... 75 °C
IP66
PC-plastic
red, similar to RAL 3000
approx. 475 g
W: 135 mm H: 135 mm D: 61 mm
3
4
5
Please take note, our part no. 769910 and 769911 can be used as spare keys.
6
Substitute for 761695.
To indicate that the detector is "out-of-order" the operator has to insert the paper inlay, which has ​
a corresponding pictogram and wording.
7
1 x glass 704910
1 x key and “out of order” sign respectively “Außer Betrieb”
8
Accessories
704910 Spare glass for MCP
769910 Plastic key for large MCP
769911 Metal key for large MCP
706030
9
Manual call point IP67, small housing, red
1
Features
• Sealed to IP 67
• Unique ‘plug and play’ installation concept
• Anti-tamper facility
• Enhanced aesthetics and compact design
• Approved to EN 54-11
The outdoor MCP is an IP 67 sealed product. The enhanced environmental protection ​
allows the unit to be installed in many external environments where water and dirt are likely​
to be present, making it a true waterproof and outdoor product.
The manual call point has a unique ‘plug and play’ concept designed specifically to reduce ​
installation time. The product utilizes a special terminal block, where all initial installation ​
cabling is terminated. This terminal block is then simply connected to the back of the MCP. ​
The housing is supplied with three standard 20mm knock outs for cable entries, accom­
modating all types of surface wiring installations.
The MCP also helps to preserve the integrity of the overall system as illegal removal of the ​
product lid will result in the call point operating and the system triggering an alarm.
10
Technical Data
13
Application temperature
Storage temperature
Air humidity
Type of protection
Material
Weight
Detector specification
Dimensions
11
12
-30 °C ... 70 °C
-30 °C ... 70 °C
< 95 % non condensing
IP 67
PC/ABS
approx. 240 g
EN 54-11
W: 97.5 mm H: 93 mm D: 71 mm
14
15
1 x Cable gland included
Accessories
706031 Spare glass pane (5 pcs)
706032 Spare key
706033 Plastic cover
117
Manual Call Points
Special Design
Manual Call Point for Hazardous Areas
706030.EX
Ex manual call point IP67, small housing, red
1
Approval: LPCB, ATEX
Features
• Sealed to IP67
• Unique ‘plug and play’ installation concept
• Anti-tamper facility
• Enhanced aesthetics and compact design
• Approved to EN 54-11
The Ex MCP is built especially for installation in hazardous areas. It is intended for outdoor ​
use within intrinsically safe systems using suitable barriers.
The outdoor MCP is an IP 67 sealed product. The enhanced environmental protection ​
allows the unit to be installed in many external environments where water and dirt are likely​
to be present, making it a true waterproof and outdoor product.
The manual call point has a unique ‘plug and play’ concept designed specifically to reduce ​
installation time. The product utilizes a special terminal block, where all initial installation ​
cabling is terminated. This terminal block is then simply connected to the back of the MCP. ​
The housing is supplied with three standard 20mm knock outs for cable entries, accom­
modating all types of surface wiring installations.
The MCP also helps to preserve the integrity of the overall system as illegal removal of the ​
product lid will result in the call point operating and the system triggering an alarm.
Technical Data
Application temperature
Storage temperature
Air humidity
Type of protection
Material
Weight
Detector specification
ATEX certificate
Ex-category
Dimensions
-25 °C ... 70 °C
-25 °C ... 70 °C
< 93 % ±3% non condensing
IP67
PC/ABS
approx. 350 g
EN 54-11
Sira 06ATEX2131X
II 1GD EEXiaIICT
W: 97.5 mm H: 93 mm D: 71 mm
! Attention – cable glands not included in delivery.
Accessories
706031 Spare glass plane (5 pcs)
706032 Spare key
706033 Plastic cover
764744 Ex-barrier
118
www.hls-austria.com
Manual Call Points
Special Design
1
761697
2
Explosion-proof conventional manual call point, IP66
1
Approval: VdS, PTB 97 ATEX 3197
Explosion-proof encapsulated conventional manual call point for hazardous areas in ​
conformity with EN 54-11 Type B for the manual actuation of a fire alarm and/or a hazard ​
alarm, as a detector for usage in explosion-hazardous areas both inside and outside.
3
The operating front foil has been designed as a double-sided insert. Complementary to the ​
symbolism conforming to the standards for manual call points in compliance with EN 54-​
11 (Type B), it has a symbol and multilingual text on the back for the ‘out of order’ status ​
of the detector and is always available for possible maintenance work.
4
5
The labeling foil of the manual call point also has a double-sided design. In compliance ​
with EN 54-11, it contains the standard symbol of a burning house. On the back, the ​
symbol is supplemented with the word “FIRE” (multilingual).
6
Technical Data
Data according to ATEX:
Ex-category
Explosion protection
Common technical data:
Operating voltage
Alarm current
No. of detector/zone
Circuit
Connection terminal
Application temperature
II 2G
Ex e d mb IIC T6, T5
7
12 ... 24 V DC
approx. 9 mA
max. 10 detectors per Zone (according to VdS)
1 k/10 k (internal)
0,6 mm ... 4 mm²
-55 °C ... 65 °C
-55 °C ... 85 °C (T5)
-55 °C ... 85 °C
IP66
Glass fiber reinforced polyester resin
red, similar to RAL 3000
approx. 1.8 kg
DIN 14678 Form K
W: 136 mm H: 138 mm D: 88 mm
Storage temperature
Type of protection
Housing
Color
Weight
Detector specification
Dimensions
8
9
10
Substitute for 761696.
Out of
11
Außer
Order
Betrieb
Please note, an allen key (size 4) is needed for opening and resetting
the MCP,
and is not ​
included in the scope of delivery.
incl. 1 x glass pane 704910, 1 x kit of double-sided operating front foil (with “out of order” on ​
the back), 1 x kit of double-sided labeling foil (multilingual)
Accessories
fuera
de servicio
704910 Spare glass pane for MCP housings
961650 Cable gland
Out of
Order
fuera
de servicio
12
hors
service
13
Außer
Betrieb
hors
service
POZAR
14
FEUER
FIRE
FEU
FUEGO
15
Feuerwehr
Operating front foils and labelling
foils
FEUER
POZAR
FIRE
FEU
FUEGO
Feuerwehr
119
Manual Call Points
961699
Special Design
Ex stop-button (conventional) IP66, blue housing
1
As 761697 but located in a blue housing, conforms to EN 12094-3. Therefore, it ​can be
used as an electrical stop-button for gas extinguishing systems even in areas with ​explosion hazards.
961698
Ex manual call point (conventional) IP66, yellow housing
As 761697 but located in a yellow housing, conforms to EN 12094-3. There­fore, it can be
used as an electronic control unit for gas extinguishing systems even in ​areas with explosion hazards.
1
120
www.hls-austria.com
1
2
3
4
5
6
7
8
9
10
Transponders
esserbus
122-132
11
12
13
14
15
121
Transponders
esserbus
Professional fire detection systems are expected to provide more than reliable fire detec­
tion and signaling alarms to the fire department. Over time, the continuous progress in ​
technical units has led to many improvements in monitoring and control systems. At the ​
same time the specifications of the European standards are becoming more and more ​
demanding. These complex requirements towards control and monitoring of individual ​
parts of a unit was reason enough to redesign our assortment of esserbus transponders.
Essentially the new assortment consists of the so-called "alarm transponder" which is used ​
for both the connection of non-addressable detectors (point-type detectors, manual ​detectors and special detectors) as well as for the operation of conventional alarm ​signaling
devices (signaling devices, signal flasher and combination alarm signaling ​devices). Monitoring of the lines in accordance with the latest standards is ensured via ​"EOL modules"
(end-of-line modules).
The second part is formed by the "FCT" (fire control transponder) and the IQ8TAL being ​
loop-powered input and output transponders with a contact input and a floating relay ​
output for monitoring of contacts and transmission of technical alarms for equipment ​
monitoring.
These modules are for interfacing to other disciplines which are not a part of the fire detec­
tion system itself. Thanks to their intelligent concept they significantly expand the range of ​
monitoring and control functions as part of the building management.
esserbus transponders need ONLY ONE loop address per device.
122
www.hls-austria.com
Transponders
808623
esserbus
1
esserbus alarm transponder 4 IN 2 OUT
1
Approval: VdS
Features
• Only one loop address is needed per transponder
• Conventional connection of standard fire ​detectors
•
•
•
•
•
•
•
•
•
•
•
•
•
and signaling devices
Loop monitoring in compliance with EN 54-13
Integrated line insolator
Programmable relay outputs
Programmable relay reset function
Max. 100 transponders per fire alarm control ​
panel
Max. 31 transponders per loop
Max. 127 detector zones per loop
Detector numbers per zone input of the ​transponder:
Max. 30 conventional detectors (without SOC)
Max. 10 conventional detectors (with SOC)
Max. 10 Manual call points (MCP)
Max. 10 Technical Alarm Modules (TAM)
Max. 5 audible alarm devices per each output ​
(observe calculation table in tools 8000)
2
The esserbus transponder functions as a device on the multifunctional primary line. The ​
connection of four zones with automatic standard detectors, manual call points (non-​
addressable) as well as special detectors is possible. In addition, two programmable relay ​
outputs are also available.
Both relay outputs of the transponder may be used to reset a connected third-party ​
detector. The reset function relates to the corresponding special detector, e.g. by switching ​
the appropriate input to GND or by a short interruption of the detectors supply voltage. ​
Therefore the control mode >Reset-Relay< as well as the desired relay operation mode ​
(normally closed or open) must be configured with the programming software tools 8000 ​
from V1.15 and above. The relay output will be activated for the selected reset time (1 to ​
14 seconds) if the assigned input (G1 for relay 1 / G2 for relay 2) of the transponder is ​
reset. Refer to the detectors manual for the required reset time.
3
4
5
Monitoring via the EOL terminating devices (Part no. 808624/808626) is required for the ​
connection of fire detectors and for the controlling of alarm signaling devices. The ​
enclosed resistors can be used to connect the floating contacts.
6
The esserbus alarm transponder requires an external voltage supply for operation of 4
monitoring inputs. An optional Voltage ​Converter (Part no. 781336) is also required for
12V DC operation. The esserbus alarm ​transponder external voltage supply can be monitored during operation. The transponder relay outputs and esserbus loop operation are
powered directly from the loop and requires no external power supply.
7
8
The EOL-I terminating device (Part no. 808626) is to be used for standard-compliant ​monitoring of detector zone inputs. The EOL-O (Part no. 808624) is to be used for ​standardcompliant monitoring of connected alarm signaling devices.
9
Technical Data
External power supply:
Operating voltage
Quiescent current @ 12 V DC
Quiescent current @ 24 V DC
Current consumption @ 12 V DC
Current consumption @ 24 V DC
esserbus loop power supply:
Operating voltage
Quiescent current @ 19 V DC
General technical data:
Contact load relay
Ambient temperature
Storage temperature
Type of protection
Weight
CE certificate
Dimensions
10 ... 28 V DC
approx. 12 mA
approx. 6 mA
max. 120 mA
max. 100 mA
10
11
8 ... 42 V DC
250 μA
30 V DC / 1 A
-10 °C ... 50 °C
-25 °C ... 75 °C
IP40 (with housing), IP55 (with high IP housing)
approx. 28 g
0786-CPD-20947
W: 82 mm H: 72 mm D: 20 mm
12
13
Installation Accessory Pack: 6x10 K, 4x1 K resistors
14
Accessories
788603.10
788600
788650.10
788601
788651.10
788655
788656
808624
808626
Module housing for snap-on mounting rail
Housing surface mount, gray
Housing surface mount, white
Housing flush mount, gray
Housing flush mount, white
High IP housing base
High IP housing
EOL-O Terminating device
EOL-I Terminating device
15
123
Transponders
esserbus
808623.10
esserbus transponder 4 IN 2 OUT for UniVario
1
Approval: VdS
The interface connects max. 2 industrial detectors from the UniVario product range. These
detectors are supplied with energy via the 9 V DC group voltage input. For meeting the ​
standard requirements of monitoring, an EOL-UV terminal element is connected to the
detector base of the UniVario detector. The interface requires external voltage supply. Addi­
tionally, two optionally monitored relay outputs are available.
Technical Data
Features
• Loop monitoring in compliance with EN 54-13
• Integrated line insolator
• Programmable relay outputs
• Programmable relay reset function
• Max. 100 transponders per fire alarm control ​
panel
• Max. 31 transponders per loop
• Max. 127 detector zones per loop
• Detector numbers per zone input of the ​transponder:
• Max. 30 conventional detectors (without SOC)
• Max. 10 conventional detectors (with SOC)
• Max. 10 Manual call points
• Max. 10 Technical Alarm Modules (TAM)
• Max. 5 audible alarm device (observe calculation ​
table in tools 8000)
External power supply:
Operating voltage
Quiescent current @ 12 V DC
Quiescent current @ 24 V DC
Current consumption @ 12 V DC
Current consumption @ 24 V DC
esserbus loop power supply:
Operating voltage
Quiescent current @ 19 V DC
General technical data:
Contact load relay
Ambient temperature
Storage temperature
Type of protection
Weight
CE certificate
Dimensions
www.hls-austria.com
8 ... 42 V DC
250 μA
30 V DC / 1 A
-10 °C ... 50 °C
-25 °C ... 75 °C
IP40 (with housing), IP55 (wirh high IP housing)
approx. 28 g
0786-CPD-20947
W: 82 mm H: 72 mm D: 20 mm
The transponder must be supplied with 24 V DC external power supply (Ubext) when used for
monitoring of Univario detectors. 781336 DC/DC converter can be used for conversion of 12 V
DC power supply to 24 V DC.
Installation Accessory Pack: 6x10 K, 4x1 K resistors
Accessories
788603.10
788600
788650.10
788601
788651.10
788655
788656
808624
808626
124
10 ... 28 V DC
approx. 12 mA
approx. 6 mA
max. 120 mA
max. 100 mA
Module housing for snap-on mounting rail
Housing surface mount, gray
Housing surface mount, white
Housing flush mount, gray
Housing flush mount, white
High IP housing base
High IP housing
EOL-O Terminating device
EOL-I Terminating device
Transponders
808600.230
esserbus
1
esserbus transponder FCT set 230 V
1
Approval: VdS
2
The FCT is used for the monitoring and operation of fire control systems such as ventila­
tion, pressure monitor pumps, extinguishing agent sprinklers, fire dampers, smoke control ​
flaps, elevators and many more. Time-dependent machine shutdowns can be carried out ​
via two freely programmable relays. The pluggable modules (up to two modules can be ​
connected) are each equipped with a contact input for operational feedback.
3
The comprehensive "fail-safe" function ensures that the transponder maintains full func­
tionality and remains a self-sufficient activation device even if the fire alarm control panel ​
or field bus fails.
4
Using the 230 V version the mains voltage can be switched directly and be simultaneously ​
used to power the transponder output. It is also possible to indirectly monitor the function
of the ​mains voltage using internal logic.
5
• Time-dependent control of relay outputs
• Optional: relay outputs with programmable ​
The esserbus transponder FCT 12-24 V or 230 V is used as a loop device for the IQ8Con­
trol or FlexES control fire alarm control panels. The tools 8000 programming software (as ​
of version V1.15.1) is necessary for the start-up.
6
• Reduction of amount of data transmitted to panel
Technical Data
Features
• 230 V AC operation with optional function monit­
oring
• Comprehensive fail-safe function during failure of ​
the loop or mains voltage
• Freely programmable relays
• Monitoring contacts for monitoring of external ​
devices
impulse lengths
via build-in logic processing
• Integrated loop isolator
• Optional IP protection base for usage in difficult ​
ambient conditions
External power supply:
Rated voltage
Rated frequency
Rated current
esserbus loop power supply:
Operating voltage
Quiescent current @ 19 V DC
General technical data:
Contact load relay
Connection terminal
Ambient temperature
Storage temperature
Type of protection
CE certificate
Dimensions
7
230 V AC
50 ... 60 Hz
0.01 A
8
8 ... 42 V DC
45 μA
30 V DC/4 A, 230 V AC/4 A
max. 2,5 mm²
-5 °C ... 45 °C
-10 °C ... 50 °C
IP30 (with housing)
IP55 (with high IP housing)
0786-CPD-20991
W: 235 mm H: 61.5 mm D: 140 mm
9
10
The FCT cannot be operated in the following systems:
FACP 80, System 3000 (FACP 3007/3008), FACP 8008, FACP 8000 C/M, Extinguishing panel ​
8010
11
- FCT control module
- 1x FCT electronic module (part no. 804981)
- surface mounted housing (part no. 788653)
12
Accessories
788655
804981
808600.24
High IP housing base
FCT electronic module
13
esserbus transponder FCT set 12 - 24 V
14
1
Approval: VdS
As 808600.230, but 24 V operating voltage.
15
Technical Data
External power supply:
Operating voltage
Current consumption @ 24 V DC
Contact load relay
10 ... 30 V DC
approx. 10 mA, max. 100 mA
30 V DC/4 A, 230 V AC/4A
The FCT cannot be operated in the following systems:
FACP 80, System 3000 (FACP 3007/3008), FACP 8008, FACP 8000 C/M, Extinguishing panel ​
8010
125
Transponders
804981
esserbus
IQ8FCT electronic module
1
Pluggable electronic module for FCT expansion with another monitoring contact input and
relay output.
Technical Data
Features
• Tool-free installation on the FCT through simple ​
Quiescent current @ 19 V DC
Alarm current
No. of modules/loop
Operation indicator
Alarm display
approx. 45 μA
approx. 9 mA
max. 127 per loop
green LED
red LED
connection of the module
• Contact input for monitoring fire event controls
• Addressable for individual localization of the fire ​
event control
• Integrated isolator
• Relay output for control of fire protection equipment
804980
IQ8TAL electronic module
As 804981 but, with TAL functionality (1 input / 1 output)
1
Technical Data
Quiescent current @ 19 V DC
Alarm current
No. of modules/loop
Operation indicator
Alarm display
808610.10
approx. 45 μA
approx. 9 mA
max. 127 per loop
green LED
red LED
esserbus transponder 12 relays 8bit
1
Approval: VdS, BOSEC
Features
• Only one loop address is needed per transponder
• Max. 100 transponders per fire alarm control ​
panel
• Max. 32 transponders per loop
• Max. 32 transponders per detector zone
The esserbus transponder works as a loop device on the multi-functional primary line. ​
With the 12 relays module, it is possible to expand the number of control groups per
control unit. ​Depending on the control unit, it can be integrated or used with fire detectors
in mixed ​operation. The esserbus transponder can be optionally extended by adding the
additional ​isolator board 788612. esserbus transponder voltage supply: via the multi-functional ​primary line. The esserbus transponder can be wired with an external switching
voltage of ​12V DC or 24V DC for the K1 to K12 relays. The external voltage supply of the
transponder ​can be programmed to be monitored in the customer data in the operating
mode. In the ​“floating” operating mode, no external switching voltage of the relays is
necessary. 11 ​relays are freely programmable. The maximum line length from the transponder to the ​external device is up to 1000 m.
Technical Data
External power supply:
Operating voltage
Quiescent current @ 12 V DC
esserbus loop power supply:
Operating voltage
Quiescent current @ 19 V DC
General technical data:
Contact load relay
Ambient temperature
Storage temperature
Type of protection
Weight
CE certificate
Dimensions
10 ... 28 V DC
approx. 3 mA
8 ... 42 V DC
250 μA
30 V DC / 1 A
-10 °C ... 50 °C
-25 °C ... 75 °C
IP40 (with housing), IP55 (with high IP housing)
approx. 110 g
0786-CPD-20611
W: 150 mm H: 82 mm D: 20 mm
External power supply is only optional - the transponder is fully operational with loop powering
only.
Accessories
788612
788600
788650.10
788601
788651.10
788655
788656
126
www.hls-austria.com
Loop isolator PCB
Surface mounting housing gray, similar to RAL 7035
Surface mounting housing white, similar to RAL 9003
Flush mounting housing gray, similar to RAL 7035
Flush mounting housing white, similar to RAL 9003
High IP housing base
High IP housinf
Transponders
808611.10
esserbus
1
esserbus transponder 32 LED
1
Approval: VdS, CNBOP, BOSEC
2
Features
The esserbus transponder works as a loop device on the multi-functional primary line. 32 ​
outputs for direct LED control (e.g. indicator) are found on this esserbus transponder ​
module. There is one terminal screw per output on the switching mechanism. The module ​
can be extended by adding the additional isolator board 788612. esserbus transponder ​
voltage supply: via the multi-functional primary line. The esserbus transponder requires an ​
external power supply.
The external voltage supply of the transponder can be programmed to be monitored in ​
operating mode. The maximum line length from the transponder to the external device is ​
up to 100 m.
• Only one loop address is needed per transponder
• Max. 100 transponders per fire alarm control ​
Technical Data
5
panel
• Max. 32 transponders per loop
• Max. 32 transponders per detector zone
Operating voltage
Quiescent current @ 12 V DC
Ambient temperature
Storage temperature
Type of protection
Weight
Dimensions
3
4
10 ... 15 V DC
approx. 3 mA
-10 °C ... 50 °C
-25 °C ... 75 °C
IP40 (with housing)
approx. 95 g
W: 150 mm H: 82 mm D: 20 mm
6
7
Accessories
788612
788600
788650.10
788601
788651.10
808613.30
Loop isolator PCB
Surface mounting housing gray, similar to RAL 7035
Surface mounting housing white, similar to RAL 9003
Flush mounting housing gray, similar to RAL 7035
Flush mounting housing white, similar to RAL 9003
8
esserbus transponder SIE
9
1
Approval: VdS
Features
• Only one loop address is needed per transponder
• Max. 100 transponders per fire alarm control ​
panel
• Max. 31 transponders per loop
• Max. 32 transponders per detector zone
The esserbus transponder SIE is designed for operation as Standard Interface Extin­
guishing (SIE) for the analog loop (esserbus / esserbus-PLus) of the Fire Alarm System ​
8000 and IQ8Control.
10
An external power supply of 12 V DC or 24 V DC can be connected to the esserbus ​transponder. The voltage converter (Part no. 781336) is required for 12 V DC operation. ​The
transponder’s external voltage supply can be programmed with supervision.
11
Technical Data
12
Operating voltage
Quiescent current @ 12 V DC
Current consumption
Contact load relay
Ambient temperature
Storage temperature
Type of protection
Weight
Dimensions
10 ... 28 V DC
approx. 10 mA
max. 120 mA
30 V DC/1 A
-10 °C ... 50 °C
-25 °C ... 75 °C
IP40 (with housing)
approx. 28 g
W: 82 mm H: 72 mm D: 20 mm
13
14
1 x additional equipment pack with 3.3 k and 680 R terminating resistor for SST
15
Accessories
788603.10
788600
788650.10
788601
788651.10
788612
781336
Module housing for C-mounting bar or top hat rail mounting
Housing surface mount, gray
Housing surface mount, white
Housing flush mount, gray
Housing flush mount, white
Loop isolator PCB
DC/DC converter output voltage
127
Transponders
808615
esserbus
esserbus communication transponder
1
With this esserbus transponder the extinguishing relay output 8010 can be integrated on ​
the bus of panel 8000, IQ8Control and FlexES, thus enabling several extinguishing zones to ​
be networked with each other. On each bus, a maximum of eight 8010 extinguishing relay ​
outputs can be operated and respectively a maximum of 16 communication transponders ​
per FACP8000 C/M, IQ8Control and FlexES. All indicators and controls can be activated ​
from the fire alarm panel. The communication transponder occupies one address on the ​
esserbus.
Technical Data
Current consumption
Ambient temperature
Storage temperature
Type of protection
Weight
Dimensions
max. 28 mA
-10 °C ... 50 °C
-25 °C ... 75 °C
IP 40 (with housing)
approx. 28 g
W: 72 mm H: 65 mm D: 20 mm
Mounting: in the housing of the 8010 extinguishing relay output
Including loop isolator PCB (Part. No. 788612)
808619.10
esserbus FSA transponder for fire doors
1
Approval: VdS
The transponder is suitable for usage for various applications: in stand-alone operation or ​
on the esserbus. In esserbus operation, the Series 9200 automatic fire detectors and those ​
of the IQ8Quad family (see features for types) can be used as detectors in door arrester ​
systems (FSA - Fire, Failure and Shut-Off). In FSA transponder loop operation, the door ​
arrester system status is indicated on the fire alarm control panel.
For stand-alone operation, detectors of the IQ8Quad family are supported without loop ​
isolator (see features for types).
Features
• Only one loop address is needed per transponder
• Usage of series 9200 intelligent detectors (such ​
•
•
•
•
•
•
•
•
•
as OT, OTI, O²T detectors) as FSA detectors is ​
possible
Connection of IQ8Quad O detectors (Part no. ​
802371), TD Detectors (Part no. 802271), OT ​
detectors (Part no. 802373) and O²T detectors ​
(Part no. 802374) (DIBt-approved) as FSA ​detectors is possible
FSA detectors programmable as devices in the ​
loop
Status indicator of door arrester system to the fire ​
alarm control panel
Actuation of the locking device also via the auto­
matic fire detectors in non-FSA operation
Stand-alone operation of the FSA transponders is ​
possible
Usage of IQ8Quad O detectors (Part no. 803371), ​
TD detectors (Part no. 803271) and O²T detectors ​
(Part no. 803374) in stand-alone operation of the ​
FSA transponders to the standard detector group ​
is possible
Max. 100 transponders per fire alarm control ​
panel
Max. 32 transponders per analog loop
Max. 127 detector zones per analog loop
• Detector numbers per zone input of the ​transponder:
• Max. 30 conventional detectors (without SOC)
• Max. 10 conventional detectors (with SOC)
• Max. 10 Manual call points
• Max. 10 Technical Alarm Modules (TAM/TAL)
128
www.hls-austria.com
For operation, the transponder requires an external supply voltage. It is possible to monitor ​
this voltage.
Technical Data
Operating voltage
Quiescent current @ 12 V DC
Current consumption
Contact load relay
Ambient temperature
Storage temperature
Type of protection
Weight
Dimensions
10 ... 28 V DC
approx. 6 mA (from UB ext)
max. 28 mA (from UB ext)
max. 30 V DC/1 A or 48 V DC/0,5 A
-5 °C ... 50 °C
-25 °C ... 75 °C
IP 40 (with housing)
approx. 70 g
W: 72 mm H: 65 mm D: 20 mm (PC Board)
Corresponding connection examples for FSA transponder operation in stand-alone operation or ​
as a device in the fire detection System 8000 can be found in the chapter containing automatic ​
door release systems.
Accessories
788612
788603.10
788600
788650.10
788601
788651.10
808625
Loop isolator PCB
Module housing for C-mounting bar or top hat rail mounting
Housing surface mount, gray
Housing surface mount, white
Housing flush mount, gray
Housing flush mount, white
EOL-Z
Transponders
808630.10
esserbus
1
Refurbishment zone transponder RZT 8000
1
Approval: VdS
Features
The refurbishment zone transponder is a stand-alone participant on the esserbus for the ​
fire alarm system 8000, IQ8Control and FlexES Control fire alarm control panels. Individual
automatic fire ​detectors and manual call points (conventional technology) from other
manufacturers can ​be connected to the 4 zone inputs. The voltage of all 4 zones can be
configured to 24 V via ​the internal DC/DC module. An additional reset module is not
required to operate third-​party detectors.
The two relay outputs are available for general control purposes.
• Only one loop address is needed per transponder
• Max. 100 transponders per fire alarm control ​
Technical Data
panel
• Max. 31 transponders per loop
• Max. 32 transponders per detector zone
2
3
4
External power supply:
Operating voltage
Current consumption
esserbus loop power supply:
Operating voltage
Quiescent current @ 19 V DC
General technical data:
Contact load relay
Ambient temperature
Storage temperature
Type of protection
Weight
CE certificate
Dimensions
10,5 ... 15 V DC
max. 1.250 mA
5
8 ... 42 V DC
250 μA
6
max. 30 V DC / 1 A or 48 V DC/0,5 A
-10 °C ... 50 °C
-25 °C ... 75 °C
IP40 (with housing), IP55 (with high IP housing)
approx. 150 g
0786-CPD-20615
W: 150 mm H: 82 mm D: 20 mm
7
8
Whether or not a connection is possible must be individually checked in advance by the t​echnical sales department.
Accessories
788612
788600
788601
788650.10
788651.10
788605
788655
788656
808631.10
Loop isolator PCB
Housing surface mount, gray
Housing flush mount, gray
Housing surface mount, white
Housing flush mount, white
Mounting kit
High IP housing base
High IP housing
9
10
11
Refurbishment zone transponder RZT / 12 V
1
As 808630.10, but rated voltage is 12 V DC, not configurable.
12
Technical Data
External power supply:
Operating voltage
Current consumtion
10,5 ... 13,8 V DC
max. 1.250 mA
13
14
15
129
Transponders
esserbus
Accessories esserbus Transponders
788612
Loop isolator for transponders
1
Loop isolator PCB to be mounted on esserbus transponders. To isolate short circuit failure ​
and wire break on the loop.
Technical Data
Ambient temperature
Storage temperature
Weight
Dimensions
788655
-20 °C ... 50 °C
-20 °C ... 75 °C
approx. 10 g
W: 32 mm H: 20 mm D: 10 mm
High IP housing base
1
High IP housing base for extreme environmental conditions.
Technical Data
Type of protection
IP55
Accessory for FCT transponders and transponder in 788656 housing. Cable entry requires use of
cable glands 704147, 704148.
788656
High IP housing
1
Housing for FCT transponder. Can also be used for other esserbus transponder to increase
IP rating in connection with 788655.
Technical Data
Type of protection
IP55
Housing + front cover
788655 base must be ordered separatelly for IP55 protection.
808624
EOL-O terminating device
1
The EOL-O terminating device is mounted on the last control input device in the detector ​
zone and is used to monitor alarm signaling devices.
Features
• Used for monitoring of control outputs with ​
conventional alarm signaling devices being ​
connected
• Additionally recognizes creeping interruptions and ​
short-circuits
• Loop monitoring in compliance with EN 54-13
808626
EOL-I terminating device
1
The EOL-I terminating device is mounted on the last device in the detector zone and is ​
used to monitor detector zone inputs.
Features
• Used for monitoring of detector zone inputs with ​
standard fire detectors being connected
• Additionally recognizes creeping interruptions and ​
short-circuits
• Loop monitoring in compliance with EN 54-13
130
www.hls-austria.com
Transponders
esserbus
1
Technical Alarm Modules
804868
2
IQ8TAL technical alarm module 1 IN 1 OUT
1
Approval: VdS
Features
• One contact input and one floating relay output
• Voltage supply via the field bus
• Test and reset function
• Higher IP protection
• Programmable inverse monitoring functionality of ​
•
•
•
•
the contact input
Total cable length of the monitoring input line up
to ​500 m
Integrated loop isolator
Max. 127 transponder TAL electronic modules per ​
analog loop
DC/AC load switching by relay output
The IQ8TAL Technical Alarm Module is a fully-fledged loop device of the IQ8Control and
FlexES Control fire ​detection system and facilitates the detection and forwarding of technical alarms.
3
The IQ8TAL is equipped with an integrated loop isolator, a contact input and a relay output. ​
The relay can be optionally configured as a normally-closed contact or as a normally-open ​
contact. The IQ8TAL does not need a separate voltage supply.
4
In order to increase the IP protection class, the optional IP protection kit (Part No. 704965) ​
can be used.
5
The functionality of the Technical Alarm Module can be tested with the included key and the​
alarm status can be reset directly at the IQ8TAL.
6
Technical Data
Quiescent current @ 19 V DC
Contact load relay
Operation indicator
Alarm display
Connection terminal
Operating temperature
Storage temperature
Type of protection
CE certificate
Housing
Color
Weight
Dimensions
approx. 45 μA
30 V DC/AC/1 A
green LED
red LED
max. 2.5 mm² (AWG 26-14)
-20 °C ... 70 °C
-30 °C ... 75 °C
IP43 (in housing),
IP55 (with cover 704965 and cable glands 704147/48)
0786-CPD-20792
PC/ASA plastic
blue, similar to RAL 5015
approx. 110 g
W: 88 mm H: 88 mm D: 21 mm
W: 88 mm H: 88 mm D: 57 mm (with surface-mounted ​
housing)
7
8
9
10
Please note that for surface mounting, the mount housing (part no. 704981) must be used. ​
Compatible with all IQ8 Control systems with firmware V3.08 and tools 8000 V1.14 or superior.
11
2 x 10 k (terminating), 1 x 1 k (alarm), 1 x 6.8 k (inverse operation)
Accessories
12
704965 Protective kit for MCP and TAL, transparent
704981 Surface mount housing for small MCP and TAL, blue
704981
13
Surface mount housing for small MCP and TAL, blue, similar to RAL 5015
Blue, for small design electronic modules. Cable entry requires cable glands 704147,
704148.
14
15
131
Transponders
804867
1
esserbus
IQ8FCT fire control transponder 1 IN 1 OUT
Approval: VdS
As IQ8TAL 804868, but with additional FCT software functionality.
Technical Data
Color
CE certificate
gray, similar to RAL 7035
0786-CPD-20792
The FCP cannot be operated on the following systems:
Fire Alarm Control Panel 80, System 3000 (Fire Alarm Control Panel 3007/3008), Fire Alarm ​
Control Panel 8008, Fire Alarm Control Panel 8000 C/M, Extinguishing System 8010
Features
•
•
•
•
Runtime monitoring
Monitoring 2 states with one input
Steady or impulsive triggering of relay output
Max. 127 IQ8 FCT transponders per loop
704985
Accessories
704965 Protective kit for MCP and TAL, transparent
704981 Surface mount housing for small MCP and TAL, blue
Surface mount housing for small MCP and IQ8FCT, gray, similar to RAL 7035
1
Gray, for small design electronic modules. Cable entry requires cable glands 704147,
704148.
704965
Protective kit for MCP and TAL, transparent
1
Transparent, suitable for small MCPs. The cover serves as a protection to prevent inad­
vertent activation and to protect from high humidity.
Technical Data
Type of protection
IP55
Cover and two neoprene seals
Application example: Manual call point with mounted cover
132
www.hls-austria.com
1
2
3
4
5
6
7
8
9
10
Wireless Components
Wireless Modules
134-140
11
12
13
14
15
133
Wireless Components
Features
• Radiocommunication transmission features
• Interference-proof transmission via dual band ​
with frequency hopping @ 433 MHz and 868 MHz
• Bi-directional data traffic
• Permanent automatic interference monitoring of ​
transmission path
• In case of interferences, automatic modification of ​
frequency band and radiocommunication channel
• Band blocking detection
• High transmission range (in the open air: max. ​
300 m)
• Automatic interference detection due to low field ​
strength levels
Wireless Modules
The following wireless modules are only compatible with IQ8Control and FlexES Control
panel. Communica­tion between the RF devices is set up via a dual band transmission
mode. The RF-​technology applies frequency hopping to enable highest transmission security. In case of ​interference, the frequency band and the radiocommunication channels are
automatically ​modified. If the entire band and the receiver are blocked due to high interference level, a ​fault signal is transmitted to the fire alarm panel. Thus, secure and reliable
wireless trans­mission is provided.
The transmission range in open air is up to 300 m. Inside the building, the transmission ​
range varies, depending on building structure, wall thickness or use of concrete steel.
IQ8Wireless radio technology facilitates the cable-free connection of IQ8Quad automatic ​
fire detectors (with and without alarm signaling devices), manual call points and the ​
IQ8Alarm alarm signaling device to the IQ8Control and FlexES Control fire alarm system.
Already existing fire alarm systems can be expanded using the wireless technology or ​
complete fire alarm systems can be realized for smaller objects with wireless components ​
as well.
The allocation of the wireless components to a wireless transponder or wireless gateway ​
takes place via the tools 8000 programming software.
The status of the batteries is checked automatically and their necessary replacement is ​
displayed early on as a detector failure on the fire alarm control panel and/or the wireless ​
transponder*.
The optimal installation site as well as the maximum possible transmission distance can be ​
conveniently and quickly transmitted via the tools 8000 integrated field strength measure­
ment.
* during allocation of the wireless components via wireless transponder
Please take into account that the use of wireless components requires extra training, covering ​
project planning and commissioning. For further information see our training brochure.
These devices were designed, produced and labeled for operation within the countries of the ​
European Union (EU) in accordance with the current EU standards and requirements. In case the ​
device is installed outside of the EU, national guidelines and requirements must be taken into ​
consideration.
For further information, please contact your local sales representative.
max. 10 control groups
max. 32 wireless detectors
12 V DC
esserbus or
esserbus-PLus
esserbus-PLus
max.
10 wireless
call points
Connection example
134
www.hls-austria.com
Wireless Components
805593.10
Wireless Modules
1
IQ8Wireless detector base
1
Approval: VdS
2
With the IQ8Wireless base, the wireless component is located in the base onto which the ​
respective fire detectors is placed. The wireless base facilitates the connection of the ​
IQ8Quad TM, TD, O, O²T and OTG detectors via a wireless transmission line to the
esser­bus/esserbus-PLus and integrates them via wireless transponder or wireless gateway
into ​the fire alarm system.
A maximum of 32 radio bases per wireless transponder and/or 10 per radio gateway can ​
be allocated.
Wireless base
135 mm
43,5
mm
Wireless base with Detector
86
mm
Features
The wireless detector base suitable for
• Fixed heat detector (Part. No. 802171, 802177)
• Rate-of-rise heat detector (Part. No. 802271, ​
803271)
• Optical smoke detector (Part. No. 802371, ​
803371)
• O²T multisensor (Part. No. 802374, 803374)
• OTG multisensor (Part. No. 802473)
The wireless detector base features
• Individual detector identification on the control ​
panel
• Regular functionality check for each detector
• Alarm and operation display on the detector
• Alarm and fault transmission in accordance with ​
EN 54-2
• Easy detector or battery replacement with d​ etector
removal tool
• Fault signal when the mounted wireless base and ​
the inserted detector are removed
• Permanent monitoring of battery voltage
• Up to 3 years battery life depending on detector ​
type and environmental conditions
3
4
Technical Data
Operating voltage
Current consumption
Battery operating time
Range inside
Range outside
Frequency band 1
Frequency band 2
Data transmission speed
Application temperature
Storage temperature
4 x 3,6 V batteries
approx. 50 µA
approx. 3 years*
max. 30 m
max. 300 m
433 MHz with 16 channels
868 MHz with 7 channels
19,2 Kbit/s
-5 °C ... 55 °C
-20 °C ... 70 °C (w/o batteries)
15 °C ... 35 °C (with batteries)
< 95 %
IP42
0786-CPD-20622
ABS-V0
white, similar to RAL 9010
approx. 315 g (incl. batteries)
EN 54-18:2005/-25:2009
Ø: 135 mm H: 49 mm (with detector H: 88 mm)
Air humidity
Type of protection
CE certifacate
Material
Color
Weight
Specification
Dimensions
5
6
7
8
The batteries to be used are components of the device approval according to EN 54 and are ​
specified by the manufacturer. With the IQ8Wireless radio components, only the approved b​ atteries with Part no. 805597 may be used. Use of batteries other than those specified by us ​automatically voids the product’s device approval (VdS-approval) and may not be used for e​ xample
in Germany in fire alarm systems under legal building regulations.
9
10
*The battery operating time is dependent on the type of detector/device used, as well as the ​
application temperature and additional surrounding conditions. It can be substantially reduced ​
by increased current consumption of the wireless devices in the case of alarm, wireless i​nterfe​ lease
rence or poor transmission, or even possibly through contact resistance at the contacts. P
note important instructions for usage of batteries in FB 798941.
11
4 x lithium battery 3.6V (part no. 805597)
1 x IQ8 detector socket (part no. 805570)
12
Accessories
805597 4 x 3.6V lithium batteries
Room 1
Room 1
13
Room 1
14
2
1
Room 1
3
Room 1
15
Room 1
Expansion via IQ8Wireless gateway with IQ8Wireless detector base
850056
Special painting wireless detector base 805593.10
The wireless detector base is painted and delivered according to the required RAL color. ​
For identical colors, we suggest to order a suitable number for serial purposes.
When ordering please specify:
- RAL code
- Glossy, semi-matt, matt finishing
135
Wireless Components
805594.10
Wireless Modules
IQ8Wireless gateway for devices
1
Approval: VdS
Wireless base
135 mm
43,5
mm
Wireless base with detector
86
mm
Features
• The wireless gateway can be mounted between ​
detector base and IQ8Quad detector. No additional ​
wiring required
• Suitable for IQ8Quad detectors w/o alarm devices
• The connection of an remote LED indicator for ​
this detector is possible
• Wireless communication with up to 10 wireless
devices
• Maximum 10 wireless bases
• Maximum 10 wireless interfaces with IQ8MCP ​
manual call points
• Maximum 10 wireless interfaces ​with IQ8Quad/
IQ8Alarm alarm signaling devices
• All wireless devices are integrated as individually ​
addressable on the esserbus / esserbus-PLus
• esserbus integration of all radiocommunication ​
devices as individually addressable users
• The radiocommunication devices can be allocated ​
•
•
•
•
•
•
•
•
•
in up to 10 detector zones
Up to 9 wireless gateways per loop
Alarm and trouble transmission in accordance ​
with EN 54-2
Easy detector or battery replacement via detector ​
removal tool
Trouble signal when removing the gateway and ​
the detector
Permanent monitoring of battery voltage
One gateway requires one loop address
The total number of loop devices of the loop will ​
be reduced by only 12 devices for each connected ​
IQ8Wireless Gateway
Max. 18 IQ8Wireless Gateways per FACP IQ8Con­
trol C
Max. 45 IQ8Wireless Gateways per FACP IQ8Con­
trol M and FACP FlexES control
850057
This wireless gateway is especially designed for convenient and time-saving expansion of ​
an already existing IQ8Control/FlexES control fire detection system. By removing a detector ​
already installed on the loop and adding the wireless gateway to the standard IQ8 detector ​
base, up to 10 additional fire detectors equipped with wireless detector bases or 10 ​
addressable manual call points can be added to the existing system. Up to 10 components ​
with alarm signaling functions – IQ8Alarm alarm signaling devices and/or IQ8Quad fire ​
alarms with integrated alarm signaling device – can be connected per wireless gateway via ​
the universal wireless interface. And all this without any additional cabling. Depending on ​
the surrounding conditions, the wireless transmission can reach up to 200m. The wireless ​
gateway must fundamentally be operated with an IQ8Quad detector. It integrates the intelli­
gent IQ8 wireless components into the esserbus or esserbus-PLus via the wireless base or ​
wireless interface, thus making these components fully individually addressable loop ​
devices.
Up to 9 wireless gateways can be operated on the loop. Each wireless gateway reduces the ​
maximum number of esserbus devices by 12 pieces.
Technical Data
Operating voltage
Voltage supply
Current consumption
Battery operating time
Range inside
Range outside
Frequency band 1
Frequency band 2
Transmitter power
Sensitivity
Data transmission speed
Application temperature
Storage temperature
Air humidity
Type of protection
CE certificate
Material
Color
Weight
Specification
Dimensions
The standard detector base version IQ8Quad 805590 is not included in the RF gateway package.
The batteries to be used are components of the device approval according to EN 54 and are ​
specified by the manufacturer. With the IQ8Wireless radio components, only the approved b​ atteries with part no. 805597 may be used. Use of batteries other than those specified by us ​automatically voids the product’s device approval (VdS-approval) and may not be used for e​ xample
in Germany in fire alarm systems under legal building regulations.
*The battery operating time is dependent on the type of detector/device used, as well as the ​
application temperature and additional surrounding conditions. It can be substantially reduced ​
by increased current consumption of the wireless devices in the case of alarm, wireless i​nterference or poor transmission, or even possibly through contact resistance at the contacts. P
​ lease
note important instructions for usage of batteries in FB 798941.
4 x lithium battery 3.6V (Part No. 805597)
Accessories
805597 4 x 3.6V lithium batteries
Special painting wireless gateway 805594.10
As 850056 but for wireless gateway
136
www.hls-austria.com
8 ... 42 V DC (via loop)
4 x 3.6 V lithium battery
400 µA to max. 2,5 mA
approx. 3 years*
max. 20 m
max. 200 m
433 MHz with 16 channels
868 MHz with 7 channels
10 mW
-100 dBm
19,2 Kbit/s
-5 °C ... 55 °C
-20 °C ... 70 °C (w/o batteries)
15 °C ... 35 °C (with batteries)
< 95 % (non-condensing)
IP42
0786-CPD-20620
ABS
white, similar to RAL 9010
approx. 265 g (incl. batteries)
EN 54-17:2005/-18:2005/-25:2009
Ø: 135 mm H: 49 mm (with detector H: 88 mm)
Wireless Components
Wireless Modules
805595.10
1
IQ8Wireless transponder for devices, wall mount
1
Approval: VdS
136
mm
280
mm
144
mm
200 mm
39
mm
This wireless transponder is designed for wall mounting. The wireless transponder ​
communicates with up to 32 other wireless devices. These can be wireless of various types ​
from intelligent automatic fire detectors or wireless interfaces with manual call points and/​
or alarm signaling devices of the IQ8-family. Using the System IQ8Control/FlexES control, ​
the wireless transponder integrates the intelligent automatic detectors (with and without ​
alarm signaling devices), manual call point and alarming device IQ8Alarm in the esserbus / ​
esserbus-PLus via the wireless base and/or wireless interface. The detector base allows ​
esserbus integration of intelligent automatic detectors as bus devices with individual ​
addressing via the transponder. Up to 10 transponders can be operated on one loop. The ​
transponder can be linked with the loop as well as with a conventional detector zone or it ​
can be operated as a stand-alone unit. Potential-free outputs for common fault and ​
common fire are available. For system 8000 the transponder for RF devices can only be ​
connected by using a potential-free relay to 4 IN/2 Out or 1 IN transponder, because it is
not ​compatible with panel 8000 and it cannot be used as a bus device.
2
The transponder needs an external supply voltage for operation.
6
3
4
5
Technical Data
Features
• RF communication with up to 32 users
• maximum 32 wireless bases
• maximum 10 wireless interfaces with IQ8MCP ​
•
•
•
•
•
•
•
manual call points
maximum 10 control groups for wireless interface ​
with IQ8Quad/IQ8Alarm alarm signaling devices
esserbus integration of all RF devices as individu­
ally addressable users
The RF devices can be assigned in up to 32 ​
detector zones
Alarm and fault transmission in accordance with ​
EN 54-2
Connection to esserbus of IQ8Control and FlexES
Control panel as ​bus device as well as to a
conventional detector ​zones
Stand-alone operation
Potential-free outputs for common fault and ​
common fire
Operating voltage
Quiescent current @ 12 V DC
Alarm current @ 12 V DC
Quiescent current @ 24 V DC
Alarm current @ 24 V DC
Range inside
Range outside
Frequency band 1
Frequency band 2
Data transmission speed
Contact load relay
Application temperature
Storage temperature
Air humidity
Type of protection
CE certificate
Housing
Color
Weight
Specification
Dimensions
7
8 ... 30 V DC (external)
approx. 17 mA
approx. 18 mA
approx. 9 mA
approx. 10 mA
max. 30 m
max. 300 m
433 MHz with 16 channels
868 MHz with 7 channels
19,2 Kbit/s
30 V DC/1 A
-5 °C ... 55 °C
-10 °C ... 60 °C
< 95 %
IP42
0786-CPD-20621
ASA + PC
white, similar to RAL 9010
approx. 250 g
EN 54-17:2005/-18:2005/-25:2009
W: 200 mm H: 280 mm D: 39 mm (with detector H: 88 ​
mm)
8
9
10
11
12
The external power supply of the IQ8Wireless transponder can come from the fire alarm control ​
panel or from an external power unit.
The voltage for the wireless transponder can be supplied by the fire alarm control panel or an ​
external power supply. An individual, separately protected supply line is to be installed for the ​
voltage supply. The external voltage supply is monitored by the wireless transponder. If the ​
wireless transponder is installed as a device on the IQ8Control/FlexES control, fire system, ​
analog loop, a disturbance is transmitted to the fire detection control unit via the loop and is ​
indicated there.
30 up to 300 m
max. 32 wireless detectors
8 ...12
30 VV DC
DC
13
14
Max. 10 control groups
with alarm devices
15
max. 10 wireless call points
esserbus-PLus
esserbus/esserbus-PLus
Max. 3 m
137
Wireless Components
805601.10
Wireless Modules
IQ8Wireless universal interface w/o cover, red
1
Approval: VdS
The radio interface allows the IQ8 manual call point (small or large design) to be connected ​
on the wireless esserbus/esserbus-PLus loops.
The radio interface connects the intelligent IQ8 manual call point to the esserbus/powered ​
loop via the IQ8wireless transponder or the IQ8wireless gateway. Thus, the devices are ​
automatically converted into individually addressable loop devices.
Technical Data
Features
Radio interface suitable for:
• IQ8 manual call point - electronic module, large ​
design (part no. 804905/ 804906)
• IQ8 manual call point – complete package, small ​
design (part no. 804971)
• IQ8 manual call point - electronic module, small ​
design (part no. 804955), only with mounting ​
frame (part no. 704967)
• IQ8Quad detectors (with and without alarm ​signaling devices)
• IQ8Alarm alarm signaling device (part no. ​8073xx
and 8072xx)
Radio interface features:
• The IQ8 components are individually identified on ​
the fire alarm control panel
• Regular functionality performance checks of IQ8 ​
components
• Fault signal when the IQ8 components are ​
removed from the fire alarm control panel
• Operating mode display directly at the IQ8 manual ​
call point and IQ8Quad detector
• Alarm and fault message transmission in compli­
ance with EN 54-2
• Easy detector removal and battery replacement ​
using multifunctional key
• Remote operation of IQ8 components possible ​
(max. 3 meters) via 2-wire line
• Constant battery status monitoring
• Early battery replacement notification at the fire ​
alarm control panel
Operating voltage
Current consumption
Battery operating time
Range inside
Range outside
Frequency band 1
Frequency band 2
Data transmission speed
Application temperature
Storage temperature
Air humidity
Type of protection
CE certificate
Material
Color
Weight
Specification
Dimensions
4 x 3,6 V batteries
approx. 30 μA
approx. 3 years*
max. 30 m
max. 300 m
433 MHz with 16 channels
868 MHz with 7 channels
19,2 Kbit/s
-5 °C ... 55 °C
-20 °C ... 70 °C (w/o batteries)
15 °C ... 35 °C (with batteries)
< 95 % (non-condensing)
IP42
0786-CPD-20623
PC/ASA plastic
red, similar to RAL 3020
approx. 285 g (incl. batteries, without attachment)
EN 54-18:2005/-25:2009
W: 135 mm H: 135 mm D: 20 mm (without a​ ttachment)
Small manual call points must be used with mounting frame Part no. 704967.
The batteries to be used are components of the device approval according to EN 54 and are ​
specified by the manufacturer. With the IQ8Wireless radio components, only the approved b​ atteries with Part no. 805597 may be used. Use of batteries other than those specified by us ​automatically voids the product’s device approval (VdS-approval) and may not be used for e​ xample
in Germany in fire alarm systems under legal building regulations.
*The battery operating time is dependent on the type of detector/device used, as well as the ​
application temperature and additional surrounding conditions. It can be substantially restricted ​
by increased current consumption of the wireless devices in the case of alarm, wireless i​nterfe​ lease
rence or poor transmission, or even possibly through contact resistance at the contacts. P
note important instructions for usage of batteries in FB 798941.
4 x lithium battery 3.6V (Part No. 805597)
Accessories
704967 Mounting frame for small MCP, red
805603 IQ8Wireless-mounting frames for IQ8Alarm, red
805601.10
805602.10
Application example for large MCP
138
www.hls-austria.com
704967
Wireless Components
805602.10
Wireless Modules
1
IQ8Wireless universal interface w/o cover, white
1
Approval: VdS
2
As 805601.10 but white color.
Accessories
3
704967 Mounting frame for small MCP, white
805603 IQ8Wireless-mounting frames for IQ8Alarm, white
805604 IQ8Wireless-mounting frames for IQQuad, white
4
805603
5
IQ8Wireless mounting frames for IQ8Alarm, red and white
1
The mounting frame is used for the mounting of the IQ8Alarm alarm signaling devices onto​
the IQ8Wireless wireless interface 805601.10/805602.10.
6
Technical Data
Color
red, similar to RAL 3020
white, similar to RAL 9010
approx. 64 g
W: 133 mm H: 133 mm D: 21 mm
Weight
Dimensions
7
1 x mounting frame red
1 x mounting frame white
=
IQWireless interface +
IQ8Alarm
8
+
IQWireless interface
805601.10 (red) or
805602.10 (white)
9
+
Mounting frames
805603
10
IQ8Alarm devices
8072xx or 8073xx
11
Application example
805604
IQ8Wireless mounting frame for IQ8Quad detectors, white
12
1
The mounting frame is used for the mounting of the IQ8Quad fire detector with or without ​
integrated alarm signaling device onto the IQ8Wireless wireless interface 805602.10.
Technical Data
Color
Weight
Dimensions
13
white, similar to RAL 9010
approx. 41 g
W: 133 mm H: 133 mm D: 21 mm
14
=
IQWireless interface +
IQ8Quad detector with
integrated alarm device
+
IQWireless interface
805602.10
+
Mounting frame
805604
+
Standard detector base
805590
15
IQ8Quad detector
with integrated
alarm device
80238x
Application example
139
Wireless Components
704967
Wireless Modules
Mounting frame for small MCP, red and white
1
The mounting frame is useful for mounting MCPs on different international flush mount ​
boxes and IQ8Wireless interface 805601.10, 805602.10.
Technical Data
Color
red, similar to RAL 3020
white, similar to RAL 9010
W: 132 mm H: 132 mm D: 8 mm
Dimensions
2 x fastening screws are included (red and white)
or
Application example: Mounting frame with small MCP
805605
IQ8Wireless cover for wireless interface, red and white
1
For applications in which the IQ8 components are not to be directly mounted (remote ​
connection) on the IQ8Wireless wireless interface 805601.10/805602.10, the wireless ​
interface can be used with the filler panel.
Technical Data
Color
red, similar to RAL 3020
white, similar to RAL 9010
approx. 33 g
W: 133 mm H: 133 mm D: 8 mm
Weight
Dimensions
1 x red cover plate
1 x white cover plate
Max. 10 wireless MCPs
8 ... 12
30 VV DC
DC
esserbus/esserbus-PLus
esserbus-PLus
max. loop
loop length
length 3,5
3,5 km
max.
8 ... 12
30 VV DC
DC
Application example
140
www.hls-austria.com
Operation via
wireless interface and
2-wire connection
(max. 3 meter)
1
2
3
4
5
6
7
8
9
10
Detectors for Special Applications
Flame and Heat Detector
142-146
Air Duct Detector
147-149
Line Heat Detectors
150-158
Line Smoke Detectors
159-165
Aspirating Smoke Detectors
166-184
Accessories
11
12
185 13
14
15
141
Detectors for Special Applications
Flame and Heat Detector
Flame Detectors
782311
UV flame detector UniVario
1
Approval: VdS
UV flame detector for the recognition of fast developing fires with flame formation. Optical
window of detector is constantly monitored for excessive contamination appearance.
Opera­tion, fault and fire statuses are displayed via LEDs on the detector. The supply voltage
and ​the wiring take place directly via the standard detector zone at the esserbus transponder ​(part no. 808623.10). Resetting of the detector is also carried out directly via the
esserbus ​transponder (part no. 808623.10).
Technical Data
Features
• Direct linking and voltage supply via standard ​
•
•
•
•
•
detector group at the esserbus transponder (Part ​
no. 808623.10)
Base installation and alignment via included ​
mounting bracket (Part no. 783312)
High IP protection for indoor and outdoor usage
Operation and fault status displayed on the ​
detector
Self-monitoring via internal sensors
Maximum level of response sensitivity according ​
to EN54-10, Class 1
Operating voltage
Quiescent current @ 9 V DC
Alarm current @ 9 V DC
Area to be monitored
Height to be monitored
Ambient temperature
Storage temperature
Air humidity
Type of protection
CE certificate
Detector specification
Housing
Color
Weight
Dimensions
9 V DC
approx. 500 μA
typ. 15 mA
max. 676 m²
max. 45 m
-20 °C ... 80 °C
-40 °C ... 85 °C
≤ 95% (w/o condensation)
IP67
0786-CPD-20567
EN 54-10, Class 1
Die cast aluminum
red, similar to RAL 3000
approx. 945 g (incl. base and bracket)
W: 130 mm H: 140 mm D: 92 mm
Detector base and mounting bracket are not supplied!
782315
3fold-IR-flame detector UniVario
1
UniVario threefold IR flame detector ESSER 3-channel infrared flame detector for recogni­
tion of quickly developing fires with flame development. Optical windows of the IR sensors ​
are fully monitored. The detector achieves a high level of resistance towards disturbance ​
variables via 3-channel infrared evaluation. Voltage supply and connection occur directly ​
via the standard detector zone at the esserbus transponder (part no. 808623.10). The
detector is also reset ​directly via the esserbus transponder (part no. 808623.10).
Technical Data
Features
• 3-channel infrared flame detector
• High level of protection against disturbance vari­
•
•
•
•
ables due to optimized hardware and develop­ment
of special algorithms
Maximum level of response sensitivity according ​
to EN54-10, Class 1
Each optical channel has separate functional ​
monitoring
Direct linking and voltage supply via standard ​
detector group at the esserbus transponder (Part ​
no. 808623.10)
Base installation and alignment via included ​
mounting bracket (Part no. 783312)
High IP protection for indoor and outdoor usage
•
• Operation and fault status displayed on the ​
detector
142
www.hls-austria.com
Operating voltage
Quiescent current
Alarm current @ 9 V DC
Area to be monitored
Height to be monitored
Ambient temperature
Storage temperature
Air humidity
Type of protection
Detector specification
Housing
Color
Weight
Dimensions
9 V DC
approx. 2.3 mA
typ. 15 mA
max. 676 m²
max. 45 m
-20 °C ... 80 °C
-40 °C ... 85 °C
≤ 95% (w/o condensation)
IP67
EN 54-10, Class 1
Die cast aluminum
red, similar to RAL 3000
approx. 991 g (incl. base and bracket)
W: 130 mm H: 140 mm D: 92 mm
Detector base and mounting bracket are not supplied!
Detectors for Special Applications
Flame and Heat Detector
1
Heat Sensor
782310
2
Heat detector UniVario
1
For detection of open fires with fast development of heat. For usage in polluted industrial ​
environments, interior and exterior areas. Voltage supply and connection occur directly via ​
the standard detector zone at the esserbus transponder (Part No. 808623.10). The detector
is ​also reset directly via the esserbus transponder.
3
Technical Data
Features
• Microcontroller functional monitoring of heat ​
sensors as well as software and hardware
• Quick fire detection with high level of protection ​
•
•
•
•
•
against false alarms
Comparison to typical false variables using intelli­
gent evaluation algorithms
High level of electromagnetic compatibility
Various mounting possibilities
Oil-tight and high level IP 67 protection class as ​
well as resistance to impact and vibration
Buil-in alarm and temperature measurement
memory
782302
Operating voltage
Quiescent current
Alarm current @ 9 V DC
Response temperature
Ambient temperature
Storage temperature
Air humidity
Type of protection
Detector specification
Housing
Color
Weight
Dimensions
4
9 V DC
approx. 0.15 mA
typ. 15 mA
0 °C ... 90 °C
-20 °C ... 80 °C
-40 °C ... 85 °C
≤ 95%
IP67
EN 54-5 A1, A2, B, C, indices S, R
Die cast aluminum
red, similar to RAL 3000
approx. 995 g (incl. base and bracket)
W: 130 mm H: 140 mm D: 85 mm
5
6
7
Detector base and mounting bracket are not supplied!
8
Heat detector UniVario, 200 mm
9
1
Same as 782310 but with sensor rod length of 200 mm.
Technical Data
Quiescent current
Response temperature
Detector specification
Weight
10
approx. 0.25 mA
54 °C ... 400 °C
EN 54-5 A1, A2, B, C, D, E, F, G, indices S, R
approx. 1 kg
11
Detector base and mounting bracket are not supplied!
782303
12
Heat detector UniVario, 400 mm
Same as 782302 but with sensor rod length of 400 mm.
13
Technical Data
Weight
approx. 1.1 kg
14
Detector base and mounting bracket are not supplied!
782304
Heat detector UniVario, 600 mm
15
Same as 782302 but with sensor rod length of 600 mm.
Technical Data
Weight
approx. 1.2 kg
Detector base and mounting bracket are not supplied!
143
Detectors for Special Applications
782306
Flame and Heat Detector
Heat detector UniVario Flex, 2 m
1
Same as 782310 but with elastic sensor tube for installation in areas with poor accessibility such ​as shafts and canals.
Technical Data
Response temperature
Weight
54 °C ... 400 °C
approx. 1.3 kg
Detector base and mounting bracket are not supplied!
782307
Heat detector UniVario Flex, 6 m
Same as 782306 but with sensor tube length of 6 m.
Technical Data
Weight
approx. 1.4 kg
Detector base and mounting bracket are not supplied!
782308
Heat detector UniVario Flex, 9 m
Same as 782306 but with sensor tube length of 9 m.
Technical Data
Weight
approx. 1.5 kg
Detector base and mounting bracket are not supplied!
Accessories
783312
Mounting bracket for UniVario detector
1
Mounting bracket for alignment of the UniVario series detectors.
783313
UniVario standard base
1
Standard detector base for detectors of the UniVario product family.
Technical Data
Weight
Dimensions
Features
• Simple detector exchange via standard base prin­
ciple
• Fast installation via simple plug-in
• Generous space for cabling for user-friendly ​
installation
144
www.hls-austria.com
approx. 350 g
W: 130 mm H: 140 mm D: 36 mm
Detectors for Special Applications
Flame and Heat Detector
1
Explosion-Proof Detectors
761347
2
IR flame detector X 9800
1
Approval: VdS, FM, ATEX
3
The pressure-proof, fully enclosed infrared flame detector particularly distinguishes itself ​
through reliable operation in difficult conditions. An integrated LED and three relays ​
provide information regarding the state of operation, failure, and alarm. Contamination ​
resistance and heated optics to prevent condensation and formation of ice also allow for ​
external operation. Typical areas of application are turbines, petrochemistry and the auto­
motive industry.
Features
• Visual range: 90°
• Maintenance with magnets, no test lamp required
• Status display directly at the detector via 3-colour ​
LED for operation, fault and alarm
• Monitoring and resetting via esserbus transponder ​808623 in loop operation
4
Monitoring on the loop and resetting take place via the esserbus transponder 808623.
Monitoring on a conventional line requires a reset module. This device requires ​a separate
voltage supply of 24 V DC.
5
Technical Data
Operating voltage
Current consumption @ 24 V DC
Detection range
Height to be monitored
Ambient temperature
Storage temperature
Air humidity
Ex-category
Explosion protection
Type of protection
Housing
Weight
Detector specification
EC-type examination certificate
CE certificate
Dimensions
6
24 V DC
approx. 87.5 mA
max. 25 m
max. 20 m
-40 °C ... 75 °C
-55 °C ... 85 °C
< 95 % (non-condensing)
II 2 GD
EEx d IIC T5-T6, T86°C
IP66
Die cast aluminum
approx. 2.7 kg (+ 6,0 kg fixture)
EN 54-10, Class 1
DEMKO 02 ATEX 132195
0786-CPD-20779
Ø: 122 mm H: 246 mm
7
8
9
10
Please note: for mounting of the holder, a 14 mm allen key is necessary and is not included in ​
delivery.
If you intend to use the internal heater the current consumption raises to 567 mA @ 30 V DC.
11
Mounting bracket, 1 x metal EX cable gland
12
13
14
15
145
Detectors for Special Applications
761349
Flame and Heat Detector
UV/IR flame detector X 5200
1
Approval: VdS, FM, ATEX
The pressure-proof, fully enclosed ultraviolet/infrared ​flame detector, enables UV and IR
sensors to monitor the same detection zone with a ​visual angle of 90°. Triggering occurs
only by activation of the IR and UV sensors. A LED ​provides information regarding the
state of operation, failure and alarm. Three relays (fire, ​failure and additional alarm) are
integrated for connection to a fire detection system. ​Contamination resistance and heated
optics to prevent condensation and formation of ice ​also allow for external operation.
Typical areas of application are turbines, munitions ​depots, natural gas depots and aircraft
hangars.
Features
• Visual range: 90°
• Maintenance with magnets, no test lamp required
• Status display directly at the detector via 3-colour ​
LED for operation, fault and alarm
• Actuation and resetting via esserbus transponder ​
808613.10 in loop operation
Monitoring on the loop and resetting take place via the esserbus transponder 808623.
Monitoring on a conventional line requires a reset module. This device requires ​a separate
voltage supply of 24 V DC.
Technical Data
Operating voltage
Current consumption @ 24 V DC
Detection range
Height to be monitored
Ambient temperature
Storage temperature
Air humidity
Ex-category
Explosion protection
Type of protection
Housing
Weight
Detector specification
EC-type examination certificate
CE certificate
Dimensions
24 V DC
approx. 117 mA
max. 25 m
max. 20 m
-40 °C ... 75 °C
-55 °C ... 85 °C
< 95 % (non-condensing)
II 2 GD
EEx d IIC T5-T6, T86°C
IP 66
Die cast aluminum
approx. 2.7 kg (+ 6,0 kg fixture)
EN 54-10, Class 1
DEMKO 02 ATEX 132195
0786-CPD-20778
Ø: 122 mm H: 246 mm
Please note: for mounting of the holder, a 14 mm allen key is necessary and is not included in ​
delivery.
If you intend to use the internal heater the current consumption raises to 583 mA @ 30 V DC.
Mounting bracket, 1 x metal EX cable gland
146
www.hls-austria.com
Detectors for Special Applications
781443
Air Duct Detector
1
Venturi air duct housing for IQ8Quad OTblue-LKM (802379)
1
Approval: VdS
Features
Ventilation air duct housing for usage of the OTblue-LKM 802379 air duct smoke detector ​
in combination with Venturi tubes 781446, 781447 or 781448. The housing is mounted on ​
the outside of the air ducts.
The Venturi tube enters the duct and leads the air out of the duct through the detection ​
chamber of the detector back to the tube and finally back into the duct. During operation, ​
the detector and the alarm LED is visible so that an external parallel detector indicator is ​
not required.
The housing need not to be opened for maintenance purposes. Inspection of the detector is​
performed quickly and easily via a separate opening in the front of the housing.
• Single-tube air analysis system based on the ​
Technical Data
•
•
•
•
Venturi principle
Optimum utilization of air flow velocity through ​
new Venturi tube design
Integrated maintenance opening in the front cover ​
so that air duct smoke detector can be tested
Suitable for air duct widths from 0.6 to 2.8 m
Integrated air flow display
Type of protection
Housing
Color
Weight
Dimensions
2
3
4
5
IP 54
ABS plastic
gray
approx. 800 g
W: 180 mm H: 235 mm D: 183 mm
6
Construction kit includes pipe gasket and cap. The following items are not included: IQ8Quad ​
OTblue LKM or detector base as well as the Venturi tube.
Correct diameter
calculation dh:
Correct assembly site
7
Mounting on air ducts with
mounting kit part no.781449
8
Turnaround of
air flow
H
Air flow
W
d h = 2 x Hx W
H+W
9
5d
Air intake e.g.
10
Air outlet e.g.
Air flow
D
dh = D
5d
11
5d
12
Application example with detector
13
14
15
147
Detectors for Special Applications
Air Duct Detector
Accessories
802379
IQ8Quad OTblue-LKM
1
Approval: VdS
Specially addressable IQ8Quad multi-criteria detector for application as air duct smoke ​
detector in housing kit 781443. The detection methods are based on state-of-the-art ​
sensor technology that enables the detection of open fires, smouldering fires and fires with ​
intense heat generation. In addition to that, extremely small particles can be detected ​
without using ionization sensor. The loop isolator is integrated in the detector.
Technical Data
Operating voltage
Quiescent current @ 19 V DC
Air speed
Application temperature
Storage temperature
Type of protection
Housing
Weight
Detector specification
Specification
Dimensions
9 ... 42 V DC
approx. 50 μA
1 ... 20 m/s
-20 °C ... 50 °C
-25 °C ... 75 °C
IP 43 (with base + option)
ABS plastic, white, similar RAL 9010
approx. 110 g
EN 54-7, EN 54-5
EN 54-7/-17, CEA 4021
Ø: 117 mm H: 62 mm (incl. base)
Only suitable for application in air duct construction set 781443.
Accessories
805590 Standard detector base for IQ8Quad
805591 Detector base with relay contact for IQ8Quad
781444
Filter cartridge for air duct module 781443
1
Cartridge for use in unclean environmental conditions.
781446
Venturi tube for IQ8Quad air duct housing set 781443, 0.6 m
1
Venturi tube 0.6 m for application with air duct housing set 781443 with a lenght between
140 mm ​and 600 mm.
Technical Data
Material
aluminum
Required borehole in the duct: 38 mm
781447
Venturi tube for IQ8Quad air duct housing set 781443, 1.5 m
1
Venturi tube 1.5 m for application with air duct housing set 781443 with a lenght between
600 mm ​and 1400 mm.
Technical Data
Material
aluminum
Required borehole in the duct: 38 mm
Venturi tube, plastic gasket and rubber seal
148
www.hls-austria.com
Detectors for Special Applications
781448
Air Duct Detector
1
Venturi tube for IQ8Quad air duct housing set 781443, 2.8 m
1
Venturi tube 2.8 m for application with air duct housing set 781443 with a lenght between
1400 mm ​and 2700 mm.
2
Technical Data
Material
aluminum
3
Required borehole in the duct: 38 mm
Venturi tube, plastic gasket and rubber seal
4
781449
Mounting set for round and insulated air ducts
1
Mounting set for mounting the 781443 air duct housing set to round and / or insulated ​air
ducts.
5
Venturi tube, plastic gasket and rubber seal
6
781445
Weather protection housing for air duct housing set 781443
7
1
Protects the air duct detector in difficult environmental conditions such as ​outside areas.
The weather resistant housing can be subsequently fixed above the already mounted and ​
installed air duct housing 781443.
8
Technical Data
Type of protection
Material
Weight
Dimensions
9
IP65
galvanized steel
approx. 1.8 kg
Ø: 282 mm H: 280 mm
10
11
12
Opened condition
13
14
15
149
Detectors for Special Applications
Line Heat Detectors
Line Heat Detector LWM-1
761290
Line heat detector LWM-1
1
Approval: VdS
The LWM-1 enables early detection of fires or overheating. It is specifically designed for ​
application in narrow rooms or rough environmental conditions. The system consists of an ​
LWM-1 evaluation unit and a special sensor cable, which must be selected according to the ​
type of application. The integration on the loop and the resetting function is carried out via ​
the esserbus transponder 808623.
Integration on a conventional line requires a reset module. The device ​requires a separate
voltage supply of 24 V DC. For the galvanic separation of D.C. voltage ​potentials the voltage
converter 781337 is to be used in order to avoid ground faults.
Features
• Maximum sensor cable length of 300 m
• Resistant against mechanical and chemical ​
impact, corrosion, humidity and dust
• Calibration switch setting
• VdS approval as per EN 54-5 A1 applicable up to ​
7.5 m ceiling height
Technical Data
Operating voltage
Quiescent current @ 24 V DC
Current consumption @ 24 V DC
Starting current @ 24 V DC
Current consumption in the case of fault
Display
• Early fire detection with heat detector classes A1, ​
A2, B and C
• High chemical and / or mechanical resistance by ​
using special sensor cables
• 3 floating relay contacts for fire and fault signalling
• Separate reset input for resetting via esserbus ​
transponder 808623 during loop operation
Sensor cable lenght
Operating temperature
Air humidity
Type of protection
Material
Color
Weight
Dimensions
10 ... 30 V DC
approx. 25 mA
approx. 25 mA (DIFF- or MAX-alarm)
< 100 mA
max. 15 mA
LED green: in operation, permanent light; LED red: ​
alarm diff., permanent light, locked; LED red: alarm ​
max., permanent light, locked; LED yellow: fault, ​flashing light, locked
max. 300 m, dependent on ambient temperature
-20 °C ... 50 °C
≤ 95% (w/o condensation)
IP65
ABS plastic
gray similar to RAL 7035
approx. 550 g
W: 200 mm H: 120 mm D: 80 mm
For ​application in Ex areas please read the instructions in the manual.
esserbus
transponder
esserbus /
esserbus PLus
24 V DC
Application example
150
www.hls-austria.com
Monitored area
Detectors for Special Applications
Line Heat Detectors
1
Accessories
761243
2
Termination sleeve set for sensor cable
1
The set contains four thermo-shrinking sleeves for one end point.
3
4
5
761244
Connection sleeve set for sensor cable
1
The set contains six thermo-shrinking sleeves for one interconnection point.
6
7
8
761245
Sensor cable (PVC), blue
9
1
Sensor cable for use in non-aggressive atmosphere, but with high humidity for the 761290
line heat detector.
10
Technical Data
Dimensions
Operating temperature
Ø: 3.15 mm
-5 °C ... 100 °C
11
The price stated is the price per meter. Order quantity at least 5 m or a multiple thereof.
Cable clamp and anchor 970140-42 or equivalent are suitable.
761246
Sensor cable, black
12
1
Sensor cable with nylon cover for protection against acids and bases for the ​761290 line
heat detector.
Technical Data
Dimensions
Operating temperature
13
Ø: 4.8 mm
-60 °C ... 100 °C
The price stated is the price per meter. Order quantity at least 5 m or a multiple thereof.
761247
14
Sensor cable with steel braiding, black
1
15
For reducing the mechanical load of the cable under extreme conditions for the line ​heat
detector 761290, the sensor cable is additionally protected by a stainless s​ teel braid.
Technical Data
Dimensions
Operating temperature
Ø: 5.8 mm
-60 °C ... 100 °C
​ ancelThe price stated is the price per meter. Order quantity at least 5 m or a multiple thereof. C
lations or returns are not possible.
Cable clamp (without silicon sleeve) and anchor 970140-43 or equivalent are suitable.
970301
Ex-i terminal box for 970300
Ex-i terminal box for 970300 SD Series surge protection systems. Holds up to 24 ​terminals.
1 x M32 for cable diameter 12-21 mm (24 x Ex-i)
12 x M20 for cable diameter 5.5-13 mm (12 x PE/PA)
151
Detectors for Special Applications
970302
Line Heat Detectors
Cable turnbuckle for floating roof tank
1
The cable turnbuckle for floating roof tank allows to obtain continuity of electrical connec­
tion between heat detection sensor cable and evaluation unit. The cable turnbuckle, ​
installed on the border of the tank body and connected to the start/end of line box located ​
on the roof, follows the movement of the roof coiling and uncoiling the cable as the tank’s ​
roof rises and falls. The mechanism is enclosed within a stainless steel cabinet. Connection ​
cable is chemical and temperature resistant.
The unit can be installed both in vertical or horizontal position.
A removable plate allows the inspection of the state of the spring and its maintenance ​
without removing the unit from its work position.
Technical Data
Operating voltage
Type of protection
Material
Weight
Dimensions
300 V DC
IP42
stainless steel (box), carbon steel (spring)
approx. 25 kg
W: 400 mm H: 400 mm D: 150 mm
Heat sensing cable and start/end of line box (907303) are not included.
The cable must be flame retardant, chemical and temperature resistant.
Max. 4 conductors 1mm².
1 x stainless steel box incl. removable rain shield
970303
Start/end of line box for LWM-1
1
The start/end of line box installed on the floating roof forms the connection between the ​
sensor cable and the cable turnbuckle.
Technical Data
Ambient temperature
Explosion protection
Type of protection
Material
Color
Dimensions
-20 °C ... 40 °C
ATEX II 2G EEx e II
IP66
glass reinforced polyester (housing), stainless steel ​
(screws)
black (with blue label)
W: 122 mm H: 119 mm D: 91 mm
Heat sensing cable and cable turnbuckle (907302) are not included.
152
www.hls-austria.com
Detectors for Special Applications
Line Heat Detectors
1
Intelligent Line Heat Detector DTS
1
Approval: VdS, UL, ATEX
Features
• Temperature monitoring with fiber optic sensor
cable (Part No. ​970150 or 970153)
• 2 sensor channels per evaluation unit
• Open line and loop configuration of sensor cable
•
•
•
•
•
•
possible
Up to 256 freely configurable alarm zones
Up to 5 individual alarm parameters per zone
Configuration of „negative“ alerts, which can also ​
be used for ice warnings
Fiber break detection and location
Automatic fiber break recovery
Up to 1 m detection resolution along sensor cable
970120
2
The DTS system (Distributed Temperature Sensing) has the capacity to not only detect
fires ​quickly, but to also localize individual fires precisely within a few meters. This is done
unaf­fected by wind, because not only convective but also radiant and transmitted heat is
detected. Addition­ally the size and fire spread direction can be monitored over a longer
period, because the ​sensor cable is able to withstand temperatures up to 750°C without
loosing monitoring ​capability.
Not only alarm reporting is provided, but also precise temperature profile measurement
with configurable special resolution along sensor cable and configurable sampling time
intervals.
The system can be easily integrated into existing management platforms (e.g. SCADA ​
systems) by either communicating directly over Ethernet (TCP/IP) using SCPI (standard ​
commands for programmable instruments) or Modbus (IP or RTU).
3
4
5
Technical Data
Operating voltage
Power consumption
Ambient temperature
Storage temperature
Air humidity
6
10 ... 30 V DC
15 W @ 20 °C
-10 °C ... 60 °C
-40 °C ... 80 °C
< 95 %
7
Evaluation unit DTS 19", 1 km
8
Evaluation unit in a rack mount housing.
Technical Data
Weight
Dimensions
970121
9
approx. 9 kg
W: 448 mm H: 88 mm D: 364 mm 2 HU, 19"
Evaluation unit DTS 19", 2 km
10
As 970120, but with a 2 km detection range.
970122
Evaluation unit DTS 19", 3 km
11
As 970120, but with a 3 km detection range.
970123
12
Evaluation unit DTS 19", 4 km
As 970120, but with a 4 km detection range.
970124
13
Evaluation unit DTS 19", 8 km
As 970120, but with a 8 km detection range.
970220
14
Evaluation unit DTS, 1 km
As 970120, but in a wall mount housing.
15
Technical Data
Weight
Dimensions
970221
approx. 17 kg
W: 400 mm H: 500 mm D: 150 mm
Evaluation unit DTS, 2 km
As 970220, but with a 2 km detection range.
970222
Evaluation unit DTS, 3 km
As 970220, but with a 3 km detection range.
970223
Evaluation unit DTS, 4 km
As 970220, but with a 4 km detection range.
970224
Evaluation unit DTS, 8 km
As 970220, but with a 8 km detection range.
153
Detectors for Special Applications
Line Heat Detectors
Accessories
970129
Internal extention with Modbus IP connectivity
970130
Optional 2nd channel for evaluation unit DTS
Option to connect a second sensor cable to an evaluation unit or to make a redundant loop.
970131
I/O connection set
Cable connection set to connect evaluation unit relay outputs with fire alarm system.
970135
DTS interface box
1
The DTS system can easily be integrated into SCADA systems, direct process control or ​
external connections to fire control panels. The DTS interface box provides access via the ​
Modbus protocol RS 232, RS 422 and RS 485, as well as TCP/IP. Through a virtual host ​
concept the data is available for each sensor (channel) as a Modbus unit. Meaning only ​
one unit is required even for multiple channel operation. 10000 register holdings and 3000 ​
register coil definitions can be assigned flexibly to each Modbus unit.
Technical Data
Features
• Modbus: RTU or IP
• Entire temperature trace data
• Independent alarm parameter per zone
• Several status conditions such as fiber break
Operating voltage
Ambient temperature
Storage temperature
Air humidity
Weight
Dimensions
12 ... 48 V DC
-10 °C ... 60 °C
-20 °C ... 80 °C
5% to 95% (non condensing)
approx. 200 g
W: 111 mm H: 77 mm D: 26 mm
• LAN: Ethernet 10/100 Mbps, RJ 45
• Serial Interface: RS-232/422/485, DB9 male
970136
Relay controller set
1
If the application requires driving more than the embedded 20 relay outputs of the DTS ​
instrument, the relay controller sets should be used. In combination with the DTS interface ​
box it is capable of controlling up to 256 additional relay outputs per channel. Each relay ​
output can be assigned flexibly to any defined alarm condition.
Technical Data
Operating voltage
Current consumption @ 24 V DC
Ambient temperature
Storage temperature
Air humidity
Weight
Dimensions
24 V DC
approx. 350 mA (Controller)
0 °C ... 55 °C
-25 °C ... 85 °C
5% to 95% (non condensing)
approx. 200 g
W: 55 mm H: 100 mm D: 70 mm (Controller)
1 x power supply
1 x pre-programmed relay controller
1 x digital output module
1 x end module
8 x relays with accessories for easy wiring
970137
DTS extension set
The DTS Extension Set adds another digital output module and 8 relays. For example, to ​
offer 48 relays, 1 relay controller and 5 DTS Extension Sets would be necessary.
Technical Data
Operating voltage
Current consumption @ 24 V DC
Ambient temperature
Storage temperature
Air humidity
154
www.hls-austria.com
24 V DC
approx. 25 mA (each IO card/relay)
0 °C ... 55 °C
-25 °C ... 85 °C
5% to 95% (non condensing)
Detectors for Special Applications
970140
Line Heat Detectors
1
Steel anchor with plastic clamp for DTS cables
1
Features
• For indoor and outdoor applications
• Applicable for dynamic loads
• UV-stabilized: 5 times better than PA6/PA66
• Very low moisture absorption
• High chemical resistance
• Halogen free as per IEC-Norm 754-2
Self-locking plastic cable clamps with zinc-plated steel anchor, ideal for installation on ​
concrete walls and ceilings. With this mounting solution the sensor cable is fast and ​securely installed. This plastic cable clamp provides excellent resistance against corrosive ​and
chemical atmospheres as well as an uncritical characteristic relating to fire (halogen ​free).
The plastic cable clamp in combination with the metal free cable is especially suitable ​for
use in rail tunnels where metal free components are often required.
To fix the clamps on the concrete a special concrete dowel type is used. The metal dowel is ​
an anchor made of steel, which is placed into a drilled hole and anchored by deformation-​
controlled expansion. The anchor may be deployed in structures subject to dry internal ​
conditions and also in structures subject to external atmospheric exposure in humid ​
internal conditions or in other particular aggressive conditions e.g. immersion in seawater, ​
chloride atmosphere or atmosphere with chemical pollution (e.g. in desulphurization plants ​
or road tunnels where de-icing materials are used).
3
4
5
Technical Data
Ambient temperature
Type
Material
Color
Dimensions
970141
2
6
-40 °C ... 110 °C
K6 x 30/15
polyamide (clamp),
zinc plated steel (anchor)
dark grey, similar to RAL 7001(clamp)
Ø: 6 mm L: 61 mm (metal anchor)
7
Please note: for mounting of the anchor, one setting tool (Part No. 970144) is necessary and is ​
not included in delivery.
Other anchor lengths on request.
8
100 x plastic clamps
100 x anchor
1 x SDS drill
9
Stainless steel anchor with plastic clamp for DTS cable
1
As 970140 but with stainless steel anchor.
10
Technical Data
11
Type
Material
Dimensions
K6 x 30/15
stainless steel (anchor)
Ø: 6 mm L: 61 mm (metal anchor)
12
100 x plastic clamps
100 x anchors
1 x SDS drill
970142
13
Steel anchor with steel clamp for DTS cables
1
As 970140 but with steel clamp, protected by rubber. The steel clamp complies with DIN ​
3016
14
Technical Data
Material
steel zinc plated with rubber protection
(clamp)
15
100 x steel clamps
100 x anchors
1 x SDS drill
155
Detectors for Special Applications
970143
Line Heat Detectors
Stainless steel anchor with stainless steel clamp for DTS cables
1
As 970142 but with stainless steel anchor and clamp.
Technical Data
Type
Material
Dimensions
K6 x 30/15
stainless steel with rubber protection
(clamp)
Ø: 6 mm L: 61 mm (metal anchor)
100 x steel clamps
100 x anchors
1 x SDS drill
970144
Setting tool for anchor installation
To fix the metal anchor it is necessary to have one setting tool.
1 x setting tool
970145
Micro splice-box for DTS FO cable
970146
Splice-box IP67 for DTS FO cable, steel
970147
Splice-box IP66 for DTS FO cable, stainless steel
970150
FO sensor cable DTS safety FRNC
1
Fast responding sensor cable with tight buffered fiber. Compact dimensions, high flexibility ​
and good bending behaviour. High tensile strength by Aramid yarns. The cable has a ​
halogen-free and flame-retardant cable sheath.
Technical Data
Explosion protection
Material
Weight
ATEX 1 GD, 111/112
FRNC outer sheath, Armid fibers, thight-buffered fibers
approx. 17 kg /km
Sensor cable will be delivered in requested length.
156
www.hls-austria.com
Detectors for Special Applications
970151
Line Heat Detectors
Sensor cable connectors for FO cable 970150
1
To reduce deployment cost and tim, we are optionally offering preassembled pig tails. This ​
enable quick and easy onsite installation, with no need to organize a fusion splicer, splice ​
box to get the sensing cable connected to the DTS instrument. Pig tails are supplied with ​
E2000 8° angled connectors. For safe transportation and installation the connectors and ​
pig tails are covered by a flexible tube to ensure proper protection.
2
3
2x Connectors
970152
Terminators for FO cable 970150
4
970153
FO sensor cable steel FRNC
5
1
Fast responding sensor cable armoured, with stainless steel loose tubes and outer sheath. ​
High permissible tensile strength, high crush resistance. Longitudinally and laterally water­
tight. Excellent rodent protection. The cable has a halogen-free and flame retardant cable ​
sheath.
6
7
Technical Data
Explosion protection
Material
Weight
ATEX 1 GD, 111/112
FRNC outer sheath, stainless steel wires, gel-free ​stainless steel loose tube, fibres with primary coating
approx. 25 kg /km
8
Sensor cable will be delivered in requested length.
9
970154
Sensor cable connectors for FO cable 970153
As 970151 but for FO sensor cable steel FRNC (Art. No. 970153).
10
2x Connectors
970155
Terminators for FO cable 970153
11
970160
E2000 APC 8° pigtail
12
1
E2000 8° angled connectors with a 5 m pigtail offered to splice the sensing cables.
13
14
15
970161
E2000 APC adapter to connect two connectors 970160
1
Used to connect two E2000 APC (Art. No. 970160) connectors.
157
Detectors for Special Applications
970165
Line Heat Detectors
Cutting tool for FO steel sensor cable 970153
1
Recommended to cut the stainless steel tube, to properly remove the cable sheath and ​
splicing the pigtail to the sensing fiber.
970170
158
www.hls-austria.com
Cable drum for FO sensor cable 970150 or 970153
Detectors for Special Applications
Line Smoke Detectors
1
Fireray
761315
2
Fireray 50 RV with one prism
1
Approval: VdS
Features
• Compact housing
• Range 5 m to 50 m
• Robust construction
• Complies with EN 54-12 standard
• Monitoring and resetting is carried out via the ​
esserbus transponder 808623 during loop ​operation
The detector consists of an integrated infrared transmitter and receiver. The signal is
reflected by a ​prism and analysed by the receiving element. Signal reaching the threshold
will trigger an ​alarm.
3
Integration on the loop and the resetting function is carried out via the esserbus ​transponder 808623.
Integration on conventional line requires use of a reset module. The detector ​requires a
separate voltage supply of 24 V DC.
4
5
The Fireray is installed approx. 0.3 to 0.8 m underneath the ceiling and its reflector with the ​
same ceiling distance opposite. There should be no reflecting obstacles in the transmission ​
zone (approx. 2 degrees).
6
Technical Data
Operating voltage
Quiescent current @ 24 V DC
Alarm current @24 V DC
Contact load
Range
Ambient temperature
Storage temperature
Air humidity
Type of protection
Housing
Color
Weight
Detector specification
CE certificate
Dimensions
10.2 ... 30 V DC
approx. 4 mA
approx. 15 mA
max. 30 V DC / 1 A
5 to 50 m
-20 °C ... 55 °C
-35 °C ... 60 °C
0% ... 93%, (non-condensing)
lP50
ABS plastic, flame resistant
gray, similar to RAL 7035
approx. 670 g
EN 54-12
0786-CPD-20045
W: 210 mm H: 117 mm D: 120 mm
7
8
9
10
1 prism 761322
esserbus
transponder
esserbus /
esserbus PLus
Monitored area
11
12
1 retro mirror
24 V DC
Operating range: 5 up to 50 m
13
Application example
14
761316
Fireray 100 RV with four prisms
1
15
As 761315, but with four prisms.
4 prisms 761323
159
Detectors for Special Applications
761317
Line Smoke Detectors
Fireray 5000, line smoke detector, incl. controller, 100 m
1
Approval: VdS, LPCB, UL
The Fireray 5000 combines an infrared transmitter and receiver in one detector head. The
trans­mission signal is reflected by a prism and analyzed on smoke concentration by the
receiving unit. The trans­mitting/receiving unit contains an electricactuator which always
keeps the IR-ray in the optimal orientation.
Electric actuator in detector head allows for remote manual alignment via remote controller
and its LCD display, keypad and laser indicator. The automatic, self-alignment mechanism
keeps detector head perfectly aligned with reflective prism regardless of vibrations or building construction movement.
Features
• Remote system controller
• LASER assisted alignment
• Automatic contamination compensation
• Automatic IR beam path alignment
• Electric remote detector head orientation adjustment
Technical Data
Operating voltage
Quiescent current @ 24 V DC
Current consumption
Alarm current @ 24 V DC
Contact load
Range
Ambient temperature
Storage temperature
Type of protection
14 ... 28 V DC
approx. 10 mA
8 mA ... 12 mA (niedrigen Strom-Modus typ 10)
approx. 50 mA
100 mA / 30 V DC
8 ... 100 m
-20 °C ... 55 °C
-40 °C ... 85 °C
IP54
4 prisms 761322+761323
1
761317.50
Fireray 5000, line smoke detector, incl. controller, 50 m
1
As 761317, but with a 50 m detection range.
Technical Data
Range
1 prism 761322
160
www.hls-austria.com
8... 50 m
Detectors for Special Applications
761318
Line Smoke Detectors
1
Fireray Eexd, line smoke detector for EX areas
1
Approval: VdS, LPCB, ATEX
2
Explosion-proof infrared line smoke detector.
Consisting of transmitter, receiver, and remote evaluation unit for light and dark smoke.
Features
• Low current consumption
• Automatic self check drift compensation
• 3 x selectable sensitivity/threshold levels
• Remote/low level control equipment (safe area)
3
Integration on the loop and the resetting function is carried out via the esserbus ​transponder 808623.
Integration on a conventional line requires use of a reset module. The detector ​requires a
separate voltage supply of 24 V DC.
4
Technical Data
Operating voltage
Quiescent current @ 24 V DC
Alarm current @24 V DC
Range
Ambient temperature
Explosion protection
Type of protection
CE certificate
EC-type examination certificate
Housing
Weight
Dimensions
11.5 ... 28 V DC
approx. 8 mA
16.5 mA
10 ... 100 m
-20 °C ... 55 °C
II 2 GD EEx d IIB T6
IP67 (transmitter/receiver)
0786-CPD-20176
Sira 03 ATEX 1504
aluminum alloy (transmitter/receiver)
steel (controller)
approx. 4 kg (transmitter/receiver)
approx. 1.1 kg (evaluating unit)
W: 124 mm H: 121 mm D: 124 mm (Sensor)
W: 210 mm H: 260 mm D: 88 mm (evaluation unit)
5
6
7
8
1x wall bracket 761313
9
10
11
12
13
14
15
161
Detectors for Special Applications
Line Smoke Detectors
Accessories
761317.H
Fireray 5000 detector head
Additional detector head for Fireray 5000 (761317).
761317.50.H
Fireray 5000 detector head
1
Additional detector head for Fireray 5000 (761317.50).
761312
Ceiling pendant mount for Fireray
1
Ceiling pendant mount for F2000, F5000, F50RV, F100RV and universal bracket 761314
Technical Data
Weight
761313
approx. 3.4 kg
Wall bracket for Fireray Eexd
1
Technical Data
Weight
approx. 1.6 kg
Fireray Eexd is not included!
761314
Univ. bracket for F5000 or prism plate 761440/761441
1
Universal bracket for a F5000 detector head or prism plate 761440 or 761441
Technical Data
Weight
162
www.hls-austria.com
approx. 300 g
Detectors for Special Applications
761322
Line Smoke Detectors
1
1 prism for Fireray
1
Technical Data
Range
Dimensions
5 to 25 m for Fireray 2000 and up to 50 m for ​Fireray
50 RV
W: 100 mm H: 100 mm
2
3
4
761323
3 prisms for Fireray
1
The prisms are mounted on an aluminium mounting plate.
5
Technical Data
Range
Dimensions
25 to 35 m for Fireray 2000 and up to 100 m for ​Fireray
100 RV
W: 200 mm H: 200 mm
6
7
761440
Plate for 1 prism
8
1
Prism plate for 1 prism for use with bracket 761314
Technical Data
Weight
approx. 150 g
9
Prism and bracket are not included!
10
761441
11
Plate for 4 prism
1
Prism plate for 4 prisms for use with bracket 761314
12
Technical Data
Weight
approx. 300 g
Prisms and bracket are not included!
13
14
15
163
Detectors for Special Applications
Line Smoke Detectors
Open-area Smoke Imaging Detection (OSID)
1
The line smoke detector OSID using dual wavelength detects only repeatable absolute ​
smoke obscuration values, while rejecting the presence of dust particles or solid intruding ​
objects. This is already provided using the simplest configuration – one imager and one ​
emitter. One imager can work with up to seven emitters.
An optical imaging array in the OSID detector provides a wider viewing angle to locate and ​
capture images. Consequently, the system is easier to install and align and can compensate​
for drift caused by natural shifts in building structures.
Features
• Patented dual wavelength, UV & IR, particle type
•
•
•
•
•
•
•
identification
High immunity to dust, fogging, steam, reflections ​
and object intrusion
High tolerance to vibration and structural move­
ment
Easy alignment with large adjustment and viewing ​
angles
Simple installation, commissioning and mainten­
ance
Simple DIP switch configuration
3D volumetric coverage
Maximum detection range up to 150 meters
In addition, OSID requires only limited free space (15 - 20 cm) in ist line of view. Therefore,
the ​solution can be deployed safely between ceilings and supporting structures, moving ​
cranes, etc.
Each component can be mounted directly to the surface or can be secured with the ​
supplied mounting brackets.
Technical Data
Operating voltage
Range
Alignment angle
Ambient temperature
Air humidity
Type of protection
Detector specification
CE certificate
Application example
164
www.hls-austria.com
20 ... 30 V DC
< 150 m
-60° ... 60° (h), -15 ... 15° (v)
-10 °C ... 55 °C
10% ... 95% (non condensing)
IP44 (electronics)
IP66 (optics housing)
EN 54-12
0333-CPD-075387
Detectors for Special Applications
761300
Line Smoke Detectors
1
Imager, 7° coverage, 24 V DC
1
Features
• Field of view coverage: horizontal 7°, vertical 4°
Imager for use with OSID emitter (Part No.: 761303 – 761305).
2
Technical Data
Current consumption @ 24 V DC
Weight
Dimensions
approx. 4 mA @ 1 imager, 7 mA @ 7 imagers
approx. 651 g
W: 130 mm H: 198 mm D: 96 mm
3
Accessories
761310
761303
761304
761305
761301
OSID Installation Kit
Emitter - Standard Power, battery version
Emitter - Standard Power, wired at 24 V DC
Emitter - High Power, wired at 24 V DC
4
Imager, 38° coverage, 24 V DC
5
1
As 761300 but with field of view coverage: horizontal 38°, vertical 19°.
761302
6
Imager, 80° coverage, 24 V DC
1
As 761300 but with field of view coverage: horizontal 80°, vertical 48°.
761303
7
Emitter, standard power, battery version
1
Features
• Built-in 5 year battery
Emitter to be used with OSID imager (Part No.: 761300 - 761302).
The emitter has a built-in battery, so no external power supply is required.
8
Technical Data
Weight
Dimensions
approx. 563 g
W: 130 mm H: 198 mm D: 96 mm
9
Accessories
761310
761300
761301
761302
761304
OSID Installation Kit
Imager - 7° Coverage, 24 V DC
Imager - 38° Coverage, 24 V DC
Imager - 80° Coverage, 24 V DC
10
11
Emitter, standard power, wired at 24 V DC
1
As 761303 but wired.
12
Technical Data
Current consumption @ 24 V DC
761305
approx. 0,35 mA
13
Emitter, high power, wired at 24 V DC
1
As 761304 but with high powered emitter.
14
Technical Data
Current consumption @ 24 V DC
761310
approx. 0,8 mA
OSID installation kit
15
1
1 x Laser alignment tool
1 x Test filter
1 x PC cable
1 x Cleaning cloth
1 x Manual
165
Detectors for Special Applications
Aspirating Smoke Detectors
LRS Conventional Technology
761519
Laser FOCUS VLF-250 - ESSER, multilingual
1
Approval: VdS, UL, FM Global, CPCB
Active stand-alone aspirating smoke detection system based on laser technology for the
early detection of ​fires in small areas.
Integration on the loop and resetting function is carried out via the esserbus ​transponder
808623.
Integration on a conventional line requires use of a reset module. The device r​ equires a
separate voltage supply of 24 V DC.
Features
• Plug & play function (simple installation and ​
commissioning)
• Laser based smoke detection
• Programmable alarm threshold value from
0,005%/m up to 20%​/m
• Two-level air filtering
• Integrated bargraph display
• Buil-in replaceble air filter
• Air flow monitoring with adjustable fault threshold
• Connection of an extraction pipe with max lenght
of 25 m or 2 x 25 m
• Integrated debugging function
• Event memory for up to 18,000 events
• Relay output: 3 changeover relays
• Actuation and resetting is carried out via ​esserbus
Technical Data
Operating voltage
Quiescent current @ 24 V DC
Alarm current @ 24 V DC
Area to be monitored
Ambient temperature
Air humidity
Type of protection
Weight
CE certificate
Specification
Dimensions
18 ... 30 V DC
approx. 220 mA
approx. 295 mA
max. 250 m²
0 °C ... 40 °C (detector)
-20 °C ... 60 °C (sampled air)
5% ... 95% (without condensation)
IP 30
approx. 2 kg
0832-CPD-0771
EN 54-20 class A, B, C
W: 255 mm H: 185 mm D: 90 mm
Accessories
761512 Spare air filter
transponder 808623 during loop ​operation
• Stand-alone system
761519.500
Laser FOCUS VLF-500 - ESSER, multilingual
As 761519, but with a monitored area of 500 m".
Connection of an extraction pipe with max lenght of 50 m or 2 x 30 m.
Technical Data
Quiescent current @ 24 V DC
Alarm current @ 24 V DC
Area to be monitored
166
www.hls-austria.com
approx. 410 mA
approx. 490 mA
max. 500 m²
Detectors for Special Applications
761515
Aspirating Smoke Detectors
1
LRS compact - ESSER, German
1
Approval: VdS, LPCB, UL
Active stand-alone early aspirating smoke detection system using laser technology.
2
Integration on the loop and the resetting function is carried out via the esserbus ​transponder 808623.
Integration on a conventional line requires use of a reset module. The device r​ equires a
separate voltage supply of 24 V DC.
3
Technical Data
Features
• Adjustable sensitivity from 0,005%/m up to
20%​/m obscuration
• 3 programmable alarm thresholds (alarm, pre ​
alarm, main alarm).
• For an increased protection from false alarms, all ​
alarm thresholds can be given a delay of 0-60 sec
• 2 fault levels (maintenance, fault)
• 3 potential-free contacts (switching capacity
•
•
•
•
•
•
•
•
•
30 V ​DC / 2 A) consisting of 1 potential-free changeover ​contact and 2 potential-free switching
contacts
Filter and air flow monitoring for easier main­
tenance
Event memory for up to 12,000 events
For use with an extraction pipe with a total length ​
of max. 80 m or 2 x 50 m
Automatic learning function for determining ​
optimum sensitivity level (the units remain oper­
ative during this learning phase)
Main alarm, pre alarm, trouble and operation ​
status are indicated on the front panel
Loop integration and resetting is carried out via
the ​esserbus transponder 808623 during loop ​
operation
Stand-alone system
Build-in replaceble air filter
Air flow monitoring with adjustable fault threshold
Quiescent current @ 24 V DC
Alarm current @ 24 V DC
Operating voltage
Contact load
Connection terminal
Ambient temperature
Storage temperature
Air humidity
Type of protection
Housing
Color
Weight
CE certificate
Specification
Dimensions
4
approx. 170 mA
approx. 190 mA
18 ... 30 V DC
30 V DC/2 A
0.2 to 2.5 mm²
-10 °C ... 39 °C
-20 °C ... 60 °C
< 95 % (non-condensing)
IP30
polycarbonate
gray, similar to RAL 7035
approx. 1.9 kg
0832-CPD-0770 /-0986
EN 54-20, Class A, B, C
W: 225 mm H: 225 mm D: 85 mm
5
6
7
Programming via Vesda System Configuration software (VSC).
Design via ASPIRE software.
8
Accessories
761512 Spare air filter
9
10
11
12
762406
LRS compact - ESSER, English
1
13
As 761515, but with English frontplate.
14
15
167
Detectors for Special Applications
761516
Aspirating Smoke Detectors
LRS compact net - ESSER, German
1
As 761515, but with networking functionality.
Features
• Configuration via programming unit LRS ​200
(761504) / 210 (761505) or PC with PC inter­face
LRS 300 (761506) and VESDA System Configurator software (not included)
• The environmental conditions may be ​compensated by using an additional reference ​detector
• Integration of up to 99 detector units via the ​proprietary “VESDAnet™” bus system
• Indicating and operating panel can be connected ​
via the VESDAnet™ (761501, 762401)
762407
LRS compact net - ESSER, English
1
As 761516, but with English frontplate.
168
www.hls-austria.com
Detectors for Special Applications
Aspirating Smoke Detectors
1
Accessories
761501
2
Indicating and operating module LRS 110 - ESSER, German
1
Approval: VdS
3
For displaying the current smoke density and the alarm level of the LRS 100 detector unit ​
and the LRS compact/net. In addition, the alarm and fault status are shown by LEDs. ​Different functions e.g. buzzer off and reset can be controlled via the key pad. The unit is ​also
equipped with 7 freely configurable, floating contacts.
4
Technical Data
Operating voltage
Current consumption
Connection terminal
Ambient temperature
Type of protection
Housing
Color
Weight
Dimensions
18 ... 30 V DC
110 ... 130 mA
ø 0,2 ... 2,5 mm²
0 °C ... 39 °C
IP30
metal
gray, similar to RAL 7035
approx. 1 kg
W: 140 mm H: 150 mm D: 90 mm
5
6
As the LRS compact/net recognises up to three alarm states, the LED''s for main alarm 1 and ​
main alarm 2 are activated jointly.
For flush mounting, order kit with Part No. 761511 separately.
Programming via interfaced network.
762401
7
8
Indicating and operating module LRS 110 - ESSER, English
1
As 761501, but with English frontplate.
761517
9
VESDAnet™ connection box
10
1
This connection box enables external devices to be connected to VESDANet™. For ​
example, a handheld programmer LRS 200 (Part no. 761504) / LRS 210 (Part no. 761505)
or PC with PC interface LRS 300 (Part no. 761506) can be connected to configure the
system.
11
12
761506
13
LRS 300 PC-interface
1
All components on the VESDAnet™can be ​programmed via the interface and PC with VSC
software.
14
Technical Data
Current consumption
Dimensions
70 mA
W: 190 mm H: 100 mm D: 40 mm
15
The two required cables are included.
762504
Programming unit LRS 200
1
762505
Programming unit LRS 210
1
169
Detectors for Special Applications
761512
Aspirating Smoke Detectors
Spare air filter for VESDA aspirating systems
1
Two-stage air filter for detector units LRS compact (Part. No. 761515, 762406)/ LRS
compact net (Part. No. 761516, 762407)/ Laser Focus (Part. No. 761519, 761519.500).
761509
Air filter for LRS aspirating systems
1
External filter for LRS aspirating system for extremely polluted environments.
Technical Data
Color
Dimensions
170
www.hls-austria.com
gray, similar to RAL 7035
W: 206 mm H: 59 mm D: 33 mm
Detectors for Special Applications
Aspirating Smoke Detectors
1
Titanus EB Aspirating Smoke Detection
Features
2
• Highest application flexibility through modular ​
Smoke
aspirating
system
design
• Fully integrated esserbus device and direct ​
•
•
•
•
•
•
•
•
•
connection to the esserbus/esserbus-PLus ​
(powered loop)
Programming and commissioning via the fire ​
alarm control panel (System 8000 / IQ8Control / ​
FlexES)
Easy commissioning through pre-set system ​
configuration at delivery
Parameters for response sensitivity can be ​configured at the detector module
Up to 180/200 m (no air filtr) length pipe per
detector module
Up to 24/32 (no air filter) suction holes
Two-detector dependency can be set up in compli­
ance with VdS guidelines
Parallel detector indicator (Part No. 801824) can ​
be connected
System design via Titanus PipeXpress software
System diagnostics using DIAG3 tool (801549)
deep freeze
New:
• Direct reset via integrated reset function
esserbus / esserbus-PLus
Loop length max. 3.5 km
3
24 V DC
4
Manufacturer-configured for
operation with one pipe
801515.10
801521.10
X
X
801522.10
801531.10
801532.10
781521.10
781531.10
X
X
5
X
Manufacturer-configured for
operation with two pipes
X
X
"Info alarm" display at the unit
and at the fire alarm panel
X
X
X
"Pre-alarm" display at the unit
and at the fire alarm panel
X
X
X
"Fire alarm" display at the unit
and at the fire alarm panel
X
X
X
X
X
X
X
"Fault" display at the unit and
at the fire alarm panel
X
X
X
X
X
X
X
X
X
Bargraph
6
7
X
8
Plug-and-play commissioning
X
Direct connection to the
esserbus/powered loop
X
X
X
X
X
Operating temperature range
from -10°C to +55°C
X
X
X
X
X
Operating temperature range
from -40°C to +60°C
X
X
X
X
9
* Titanus Pro Sens EB and Titanus Top Sens EB for extreme temperature environments
(frozen storages e.g.) and accessories are available on request.
10
Application example
801515.10
Compact unit Titanus Pro Sens EB
11
1
Approval: VdS, FM
Active system for the early detection of fires. It serves for room and furnishing protection ​
and can be directly connected to esserbus / esserbus PLus. The compact aspirating s​ moke
detection system Titanus Pro Sens EB is completely supplied with detector module D
​ M-TP50L. Plug & Play operation for fast and simple commissioning through pre-​programmed
standard functions and pre-configured detector modules.
12
13
Technical Data
Features
• Fire and fault indication directly at the unit and at ​
the fire alarm control panel
• Fast commissioning through automatic initializing ​
•
•
•
•
process and plug & play operation
Air flow monitoring for detecting pipe burst or ​
tube blocking
Protection against disturbances when imple­
mented LOGIC SENS function is activated
Integrated and pre-configured detector module ​
(part no. 801523.10)
Integrated esserbus transponder (part no.
808623)
Operating voltage
Quiescent current @ 24 V DC
Alarm current @ 24 V DC
Contact load relay
Connection terminal
Ambient temperature
Storage temperature
Air humidity
Type of protection
Housing
Color
Weight
CE certificate
Specification
Dimensions
14 ... 30 V DC
approx. 275 mA @ 9 V fan voltage
approx. 285 mA @ 9 V fan voltage
30 V DC/1 A max. 24 W
max. 1.5 mm²
-20 °C ... 60 °C
-25 °C ... 65 °C
≤ 95% w/o condensation
IP20 (IP52 with optional sealing kit)
ABS plastic
white, similar to RAL 9018
approx. 1.35 kg
0786-CPD-20791
EN 54-20 class A, B, C
W: 200 mm H: 292 mm D: 113 mm
14
15
Isolator not included with delivery, can be optionally ordered under part no. 788612.
Pre-configured Titanus Pro Sens EB basic device including esserbus transponder, Titanus Pro
Sens EB front foil and pre-configured detector module DM-TP-​50L.
171
Detectors for Special Applications
801521.10
Aspirating Smoke Detectors
Basic unit Titanus Pro Sens EB
1
Approval: VdS, FM
Basic unit for wall mounting, ready to accommodate a DM-TP-xx detector module. ​Titanus
Pro Sens EB can be directly connected to esserbus / esserbus PLus. The unit is ​supplied
with front foil for single-pipe operation.
Technical Data
Features
• Pre-configured for connecting DM-TP-xx ​detector
module
• Optical status display for alarm and fault indica­
tion on the front foil
• Extendable for integrating up to two DM-TP-xx ​
detector modules to connect a second pipe
• Ports for two suction pipes with outside diameter ​
of 25 mm
• Port for air return pipe
Operating voltage
Quiescent current @ 24 V DC
Alarm current @24 V DC
Contact load relay
Connection terminal
Ambient temperature
Storage temperature
Air humidity
Type of protection
Housing
Color
Weight
CE certificate
Specification
Dimensions
14 ... 30 V DC
approx. 275 mA at 9 V fan voltage
approx. 285 mA @ 9 V fan voltage
30 V DC/1 A max. 24 W
max. 1,5 mm²
-20 °C ... 60 °C
-25 °C ... 65 °C
≤ 95% w/o condensation
IP20 (IP52 with optional sealing kit)
ABS plastic
white, similar to RAL 9018
approx. 1.35 kg
0786-CPD-20791
EN 54-20 class A, B, C
W: 200 mm H: 292 mm D: 113 mm
Isolator not included with delivery, can be optionally ordered under part no. 788612.
Pre-configured basic device including esserbus transponder and ​front foil.
801522.10
Basic unit Titanus Pro Sens 2 EB
1
As 801521.10, but with front foil for double pipe operation.
Technical Data
Quiescent current @ 24 V DC
Alarm current @24 V DC
172
www.hls-austria.com
approx. 295 mA at 9 V fan voltage
approx. 315 mA @ 9 V fan voltage
Detectors for Special Applications
801531.10
Aspirating Smoke Detectors
1
Basic unit Titanus Top Sens EB
1
Approval: VdS, FM
2
Basic unit for wall mounting, ready for receiving a detector module DM-TT-xx. It is ​
provided with three alarm levels for information alarm, pre-alarm and main alarm as well ​
as with a bargraph display to indicate the specific smoke density level. Titanus Top Sens EB​
can be directly connected to the esserbus / esserbus PLus.
The device is supplied with front foil for single-pipe operation.
3
Technical Data
Features
• Pre-configured for usage with DM-TT-xx ​detector
module
• Optical status display for information alarm, pre-​
alarm, main alarm and fault indication
• Integrated bar graph display to optically indicate ​
the current smoke level
• Ports for two suction pipes with an outside ​
diameter of 25 mm
• Port for air return pipe
Operating voltage
Quiescent current @ 24 V DC
Alarm current @24 V DC
Contact load relay
Connection terminal
Ambient temperature
Storage temperature
Air humidity
Type of protection
Specification
Housing
Color
Weight
Dimensions
14 ... 30 V DC
approx. 260 mA @ 9 V fan voltage
approx. 290 mA @ 9 V fan voltage
30 V DC/1 A max. 24 W
max. 1,5 mm²
-20 °C ... 60 °C
-25 °C ... 65 °C
≤ 95% w/o condensation
IP20 (IP52 with optional sealing kit)
EN 54-20 class A, B, C
ABS plastic
white, similar to RAL 9018
approx. 1.35 kg
W: 200 mm H: 292 mm D: 113 mm
4
5
6
7
Isolator not included with delivery, can be optionally ordered under part no. 788612.
8
Pre-configured basic device including esserbus transponder and ​front foil.
801532.10
Basic unit Titanus Top Sens 2 EB
9
1
As 801531.10, but pre-configured to receive up to two DM-TT-xx detector modules.
Titanus Top Sens 2 EB is directly connectable to esserbus / esserbus PLus. The device is
shipped equipped with the front foil for the double pipe operation.
10
Technical Data
Quiescent current @ 24 V DC
Alarm current @24 V DC
approx. 310 mA at 9 V fan voltage
approx. 370 mA @ 9 V fan voltage
11
12
13
14
15
173
Detectors for Special Applications
Aspirating Smoke Detectors
Detector Module for Titanus Pro Sens EB Aspirating Smoke Detection
801523.10
Detector module 0.5 %/ m Type DM-TP-50
1
Detector module for instalation in Titanus Pro Sens EB aspirating smoke detection ​systems
(Part. No. 801515.10, 801521.10, 801522.10) with a response sensitivity of 0.5 ​% light
opacity / m.
Early fire detection via HPLS technology. Installation into Titanus Pro Sens EB systems ​
without tools and adjustable via DIL switch on the outside of the detector module. The ​
parameterization option allows sensitivity adjustments for the aspirating smoke detection ​
system.
Technical Data
Features
• Response sensitivity adjustable at the module
• Fast commissioning through automatic initializing ​
Ambient temperature
Sensitivity settings
Housing
Weight
-20 °C ... 60 °C
0,5; 1,0 % / m
ABS plastic
approx. 100 g
process
• Status display for status and fault diagnosis
• Installation into Titanus Pro Sens EB without tools
• Air flow monitoring for detecting pipe burst and ​
tube blockage
801524.10
Detector module 0.10%/ m DM-TP-10L
1
As 801523.10 but with higher response sensitivity of 0.10% light opacity / m.
Technical Data
Sensitivity settings
801525.10
0,1; 0,2; 0,4; 0,8 % / m
Detector module 0.015%/ m DM-TP-01L
1
As 801524.10 but, with higher response sensitivity of 0.015 % light opacity/m.
Technical Data
Sensitivity settings
174
www.hls-austria.com
0,015; 0,03; 0,06; 0,12 % / m
Detectors for Special Applications
Aspirating Smoke Detectors
Detector Module for Titanus Top Sens EB Aspirating Smoke Detection
1
801533.10
2
Detector module 0.5%/ m DM-TT-50L
1
Detector module for application in Titanus Top Sens aspirating smoke detection systems ​
(part nos. 801531.10, 801532.10) with a response sensitivity of 0.5% light opacity / m. ​
Early fire detection via HPLS technology. Installation into Titanus Top Sens EB systems ​
without using any tools and adjustable via DIL switch on the outside of the detector ​
module. The parameter setting option allows sensitivity adjustments for the aspirating ​
smoke detection system.
3
4
Technical Data
Features
Ambient temperature
Sensitivity settings
Housing
Weight
-20 °C ... 60 °C
0,5; 1,0 % / m
ABS plastic
approx. 100 g
5
• Response sensitivity adjustable at the module
• Fast commissioning through automatic initializing ​
6
process
• Status display for status and fault diagnosis
• Installation into Titanus Pro Sens EB without tools
• Air flow monitoring for detecting pipe burst and ​
tube blockage
801534.10
7
Detector module 0.10%/ m DM-TT-10L
8
1
As 801533.10, but with a higher response sensitivity of 0.10 % light opacity/m.
Technical Data
Sensitivity settings
801535.10
9
0,1; 0,2; 0,4; 0,8 % / m
Detector module 0.015%/ m DM-TT-01L
10
1
As 801534.10 but, with a higher response sensitivity of 0.015 % light opacity/m.
Technical Data
Sensitivity settings
11
0,015; 0,03; 0,06; 0,12 % / m
12
13
14
15
175
Detectors for Special Applications
Aspirating Smoke Detectors
Accessories
801543.10
Sound absorber for Titanus EB aspirating smoke detection ​systems
1
Sound absorber for reducing sound levels in Titanus EB aspirating smoke detection ​
systems for sound-sensitive applications. The sound absorber is connected to the ​outlet
pipe and reduces the sound level during operation by up to 10 dB(A).
Installation either directly at the air release or with 10 cm maximum distance from the air ​
release.
Technical Data
Application temperature
Material
Color
Weight
Dimensions
-30 °C ... 60 °C
ABS plastic
gray, similar to RAL 7035
approx. 454 g
W: 122 mm H: 194 mm D: 96 mm
Aspirating
smoke
detector
Sound
absorber
End cap
Application example
801544.10
Air filter for aspirating smoke detectors
1
Air filter for usage in areas with interfering environmental influences e.g. dust.
Technical Data
Application temperature
Material
Color
Dimensions
-30 °C ... 60 °C
ABS plastic
gray, similar to RAL 7035
W: 122 mm H: 194 mm D: 96 mm
Filter cartridges (1 x 60 ppi, 1 x 45 ppi, 1 x 25 ppi)
801604
Replacement air filter pads for 801544.10
1
Replacement cartridge for air filters (801544.10), consisting of one fine, medium and
coarse ​filter pad each.
Filter cartridges (1 x 60 ppi, 1 x 45 ppi, 1 x 25 ppi)
1 Set
801600
Special air filter
1
Special filter for use in areas with extreme pollution high filtering performance and high
volume.
Technical Data
Dimensions
Features
• Filter cartridge filters particles up to a size of 7.5 ​
μm
• Housing resistant to different organic and inor­
ganic chemicals, fuels and hot water
176
www.hls-austria.com
L: 418 mm
Detectors for Special Applications
801605
Aspirating Smoke Detectors
1
Replacement filter element for 801600
1
Technical Data
Application temperature
Material
Dimensions
-20 °C ... 60 °C
Polypropylene
Ø: 64 mm L: 254 mm
2
3
4
801540
Detector holder for aspirating smoke detection systems Titanus EB
1
Device holder for mounting aspirating smoke detection systems to frames or for self-​
supporting mounting.
5
Technical Data
Weight
Dimensions
801541
approx. 1.16 kg
L: 92 mm W: 432 mm
6
Reset module for Titanus EB detectors
7
1
Module for resetting Titanus Pro Sens EB and Titanus Top Sens EB aspirating smoke ​
detection system via the fire alarm control panel.
8
Technical Data
Current consumption
Dimensions
5 to 50 mA
L: 45 mm W: 57 mm
9
Contact your sales representative for additional application details.
801542
10
Back-flow valve for Titanus EB
1
Valve for cleaning aspirating pipes through air purging via compressed air. In systems ​with
air purging, the non-return valve is mounted at the end of the pipe branch and ​facilitates
dirt build-up removal from pipes.
11
Technical Data
Color
Dimensions
dark gray
Ø: 25 mm
12
13
801547
Front foil Titanus Pro Sens 2 EB
1
Front foil for indicating alarms when using two detector modules.
14
15
177
Detectors for Special Applications
801548
Aspirating Smoke Detectors
Front foil Titanus Top Sens 2 EB
1
Front foil for indicating staged alarms and smoke density levels when using two ​detector
modules.
801549
DIAG3 diagnostics tool for Titanus EB
1
Diagnostics tool for Titanus EB aspirating smoke detector systems for reading the meas­
urement data and device configurations as well as for localization of faults.
Diagnostics interface, connecting cable and diagnostic software
178
www.hls-austria.com
Detectors for Special Applications
Aspirating Smoke Detectors
1
Accessories for Aspirating Smoke System
2
Technical Data
Ambient temperature
Material
Dimentions
Color
950101
-10 °C ... 60 °C
PVC
Ø: 25 mm
dark gray
3
PVC pipe, diameter 25 mm
4
1
Length=4m
10 pcs
950119
5
PVC 90° bend for 25 mm pipe
6
1
10 pcs
7
8
950104
PVC 90° angle for 25 mm pipe
9
1
10 pcs
10
11
950107
12
PVC 45° angle for 25 mm pipe
1
10 pcs
13
14
15
950110
PVC T-piece for 25 mm pipe
1
10 pcs
179
Detectors for Special Applications
950116
Aspirating Smoke Detectors
PVC sleeve for 25 mm pipe
1
10 pcs
950113
PVC end cap for 25 mm pipe
1
10 pcs
950447
PVC T-piece with opening
1 pcs
761543.10
Corrugated polyester hose
1
This article will be charged per meter.
761549
Ceiling lead-through adapter ABS
1
For instalation on flexible hose.
761542.10
Suction hose set for 25 mm pipe
1
For flexible installation in object surveillance or suspended ceilings.
Technical Data
Dimensions
L: 3000 mm
1 x T-piece, 3 m polyester hose, 1 x ceiling lead-through adapter ​with threaded joint
T-piece
False
ceiling
Suspended ceiling
Application example: monitoring of room
180
www.hls-austria.com
Pipe
Polyester hose
Aspirator sampling
assembly
Detectors for Special Applications
801602
Aspirating Smoke Detectors
1
Three-way ball valve (PVC)
1
For manual disconnection of aspirating smoke detectors from connected piping system ​
during the blow cleaning process with compressed air.
2
Technical Data
Ambient temperature
Material
Dimensions
0 °C ... 50 °C
PVC
L: 131 mm
3
includes three transition screw joints for connection to a 25 mm piping system
4
801606
Condensate trap for aspirating smoke detectors
1
Condensate trap with sintered metal filter for separation and absorption of condensed ​
liquids, used for protecting aspirating smoke detectors against humidity condensate, oil
etc.
5
Technical Data
Ambient temperature
Material
Color
Weight
Dimensions
6
0 °C ... 80 °C
ABS
light gray
approx. 620 g
W: 68 mm H: 680 mm D: 36 mm
Features
7
Air filter
• Plastic housing with manual outlet valve
• Plug connectors for attaching to a piping system
8
9
Inlet
Outlet
Condensate separator
10
Aspirating
smoke
detector
11
Outlet
12
Application example
761535
13
Adhesive, 0.5 kg can with brush-in-cap
1
Adhesive for connecting ABS and PVC pipes.
14
15
761536
PVC detergent, 1l
1
Detergent for cleaning PVC pipes and fittings before glueing.
181
Detectors for Special Applications
950123
Aspirating Smoke Detectors
PVC pipe clip for 25 mm pipe
1
20 Stück
761546.10
Pipe cutter for PVC / ABS pipes
1
Pipe cutter for plastic pipes 6-35 mm
761547
Labels-sampling points wrap round VESDA systems
1
The labels-sampling points wrap round serves for the marking of the aspirating holes of
the ​PVC/ABS pipe.
Please note the Labels-Sampling Points Wrap Round are not used for tapering the intake points.
Roll with 200 labels.
801550
Banderole for suction-reducing foil
1
Banderole for securing the suction-reducing foils on the pipe system. The red marking is ​
used for the localization of the aspirating holes in the object.
10 pcs
182
www.hls-austria.com
Detectors for Special Applications
Aspirating Smoke Detectors
1
Aspiration Reducing Foils
1
Not suitable for LRS systems with blow-free cleaning and for LRS systems in deep freeze
storages. Special aspirating foils for such application are available on request.
2
3
10 pcs
4
950298
Aspiration reducing film sheet, 2.0 mm
5
10 pcs
950299
6
Aspiration reducing film sheet, 2.5 mm
10 pcs
7
950301
Aspiration reducing film sheet, 3.0 mm
10 pcs
950950
8
Aspiration reducing film sheet, 3.2 mm
9
10 pcs
950303
10
Aspiration reducing film sheet, 3.4 mm
10 pcs
950304
11
Aspiration reducing film sheet, 3.6 mm
10 pcs
950305
12
Aspiration reducing film sheet, 3.8 mm
13
10 pcs
950306
Aspiration reducing film sheet, 4.0 mm
14
10 pcs
950311
15
Aspiration reducing film sheet, 4.2 mm
10 pcs
950307
Aspiration reducing film sheet, 4.4 mm
10 pcs
950308
Aspiration reducing film sheet, 4.6 mm
10 pcs
183
Detectors for Special Applications
950310
Aspirating Smoke Detectors
Aspiration reducing film sheet, 5.0 mm
10 pcs
950312
Aspiration reducing film sheet, 5.2 mm
10 pcs
950313
Aspiration reducing film sheet, 5.6 mm
10 pcs
950314
Aspiration reducing film sheet, 6.0 mm
10 pcs
950315
Aspiration reducing film sheet, 6.8 mm
10 pcs
950316
184
www.hls-austria.com
Aspiration reducing film sheet, 7.0 mm
Detectors for Special Applications
781332
Accessories
Reset module for hat rail mounting
1
Module for connecting a third-party detector (with relay contact for alarm and ​fault) to
conventional primary loop for remote resetting. Remote reset function can be controlled
via the relay ​contact on the reset module. Total power consumption depends on the detectors that are ​connected. The following detector types can be connected: aspirating ​smoke
detection system, flame detectors, Fireray, line type heat and smoke detectors etc.
2
1
3
Technical Data
Operating voltage
Quiescent current
Current consumption @ 12 V DC
Current consumption @ 24 V DC
Contact load relay
Dimensions
10.5 ... 28 V DC
approx. 0.5 mA (from detector zone)
approx. 1 mA (Relay active: 35 mA)
approx. 10 mA (Relay active: 55 mA)
30 V DC/1 A
W: 37 mm H: 107 mm D: 13 mm (PC-Board)
4
Version: Module housing for hat rail mounting.
781333
5
Reset module with mounting bracket
6
1
As 781332, but with mounting bracket.
Reset module including bracket and mounting material.
7
8
9
10
11
12
13
14
15
185
Notes
186
www.hls-austria.com
1
2
3
4
5
6
7
8
9
10
Alarm Devices
IQ8Alarm
188-197
Conventional
198-206
Remote Indicators
207-208
11
12
13
14
15
187
Alarm Devices
IQ8Alarm
IQ8Alarm acoustic and visual alarm according to EN 54-3. No matter whether multilingual
speech alarm, flexible signal combination or ​user-friendly programming interfaces, all
these features are also available when using ​IQ8Alarm.
32
112
112
The IQ8Alarm range offers distinct advantages vs conventional signalling devices. Saves
installation and cabling costs but provides better functional safety with loop cabling.
25
60
75
90
60
75
Features
• Completely bus supplied alarm device
• Powered loop compatible
• 5 different signaling device types:
•
•
•
•
acoustic / ​optical / acoustic - speech /
acoustic - optical / acoustic - optical - speech
Multilingual speech alarm in 5 different languages
out of 21 languages available
Alarm signaling, cancellation, evacuation and test
alarm can be ​respectively programmed in different
languages
Up to 32 alarm devices for each powered loop
Each alarm device with built-in isolator
Acoustic alarm signaling:
• Sound pressure level up to 99 dB(A) @ 1 m
• Volume programmable in 8 steps via tools 8000
• 20 different signaling tones, including DIN tone
• Speech alarm: 5 pre-programmed alarm texts and ​
other country-typical alarm signals
• 4 signal patterns, each configurable with selection
of 4 parts selected from tone and speech texts
• Acoustic and visual signal synchronisation within a
fire alarm control panel IQ8Control / FlexES Control
Optical alarm signaling:
• Flash intensity equivalent to 3W Xenon flash light
• Light intensity: max. 3.87cd effective, max. 24cd ​
peak
Advantages with IQ8Alarm at a glance:
Remote programming via standard programming software tools8000 for IQ8Quad and
IQ8Alarm individually or collectively in sectors
Voltage supply from the loop
Universal, modern design
Signaling device in compliance with EN 54 with 20 different signaling tones including DIN ​
tone in compliance with DIN 33404-3
On the following pages, you will find more detailed information about IQ8Alarm features
and types.
Technical Data
Operating voltage
Quiescent current @ 19 V DC
Load factor
Sound level
Frequency of flash
Lighting energy
Light intensity
Ambient temperature
Air humidity
Type of protection
CE certificate
Housing
Weight
Specification
Dimensions
8 ... 42 V DC (via powered loop)
approx. 55 μA
3
97 dB(A) +/- 2 dB @ 1 m
approx. 1 Hz
approx. 3 W
max. 24,4 cd peak/ 4,1 cd effective (red flash)
-10 °C ... 50 °C
< 95 % (non-condensing)
IP30
(IP65 with socket 806201 / 806202)
0786-CPD-20213
ABS plastic
approx. 300 g
EN 54-3 acoustic signaling device, EN 54-17 (isolators)
EN 54-3 acoustic speech signaling device (Q2/2011)
Ø: 112 mm D: 75 mm
Ø: 112 mm D: 90 mm (with IP 65 socket)
Please consider:
- Admissible maximum loop length at given loop diameter
- Admissible maximum number of alarm device per loop/panel
- Maximum number of 127 bus devices for each loop
- esserbus-PLus loop load factor calculator tool should be used for loop/panel calculation
Systems requirements:
IQ8Control with firmware 3.04 or higher
FlexES Control
esserbus-Plus loop micromodules
Programming software tools 8000 from version V1.09
Attention - operation with FACP'S 8000 C/M, 8007/8 is not possible!!!
Alarm signaling with speech compliant with EN 54-3 / A2 should consist of following parts:
1 - alarm tone
2 - silence
3 - speech message alarm
4 - silence
Total alarm signal should not exceed 30 seconds.
188
www.hls-austria.com
Alarm Devices
IQ8Alarm
1
IQ8Alarm
2
3
4
5
6
7
8
9
10
11
12
13
14
15
189
Alarm Devices
IQ8Alarm
IQ8Alarm - Acoustic Alarm Devices
807205
IQ8Alarm sounder, white
1
Approval: VdS
Addressable, completely bus powered and short circuit / open circuit resistant alarm s​ ignaling device compliant with EN 54-3. Provides up to 20 different programmable ​signaling
tones including DIN tone in accordance with DIN 33404 Part 3 for acoustic alarm s​ ignaling.
The volume can be set to 8 different levels. Its flat design enables optimum ​adaptation to
different interiors. It is made of shock and scratch resistant plastic. Option­ally, bases
806201 and 806202 with side cable entry, knock-outs and weatherproof protection can be ​
installed.
Technical Data
Color
Specification
white, similar to RAL 9010
EN 54-3 acoustic alarm device, EN 54-17 isolators
Accessories
806201 IP65 base, white
807206
IQ8Alarm sounder, red
1
Approval: VdS
As 807205, but red.
Technical Data
Color
Specification
Accessories
806202 IP65 base, red
190
www.hls-austria.com
red, similar to RAL 3020
EN 54-3 acoustic alarm device, EN 54-17 isolators
Alarm Devices
807322
IQ8Alarm
1
IQ8Alarm speech alarm, white
1
Approval: VdS
2
As 807205, but with additional speech alarm function.
Technical Data
Color
Specification
white, similar to RAL 9010
EN 54-3 acoustic signaling device
EN 54-3 acousitc speech signaling device (Q2/2011)
EN 54-17 isolators
3
Programmed with 5 standard languages (D/GB/FR/ES/IT).
4
Accessories
806201 IP65 base, white
5
6
807322.SV98
7
IQ8Alarm speech alarm, white - special language
1
As 807322, but with individual selection of speech message languages. Max. recording
time per ​device is 169 seconds.
8
When ordering, please note the "Ordering information for IQ8Quad and IQ8Alarm" and fill in ​
“Order form for individual combination of languages” printed in the appendix.
Cancellations or returns are not possible.
9
Programmed with an individual selection of up to 5 sets of messages in national languages.
10
Accessories
806201 IP65 base, white
11
12
13
807322.SV99
IQ8Alarm speech alarm, white - customized version
1
Same as 807322, but with individual speech message text and/or sound tone.
14
When ordering, please note the "Ordering information for IQ8Quad and IQ8Alarm" and fill in ​
“Order form for individual combination of languages” printed in the appendix.
Costs for the recording of customer specific texts and/or tones can be obtained on request.
Cancellations or returns are not possible.
15
Programmed according to customer specifications.
Accessories
806201 IP65 base, white
191
Alarm Devices
807332
IQ8Alarm
IQ8Alarm speech alarm, red
1
Approval: VdS
As 807322, but red.
Technical Data
Color
Specification
red, similar to RAL 3020
EN 54-3 acoustic signaling device
EN 54-3 acousitc speech signaling device (Q2/2011)
EN 54-17 isolators
Accessories
806202 IP65 base, red
807332.SV98
IQ8Alarm speech alarm, red - special language
1
As 807322.SV98, but red.
When ordering, please note the "Ordering information for IQ8Quad and IQ8Alarm" and fill in ​
“Order form for individual combination of languages” printed in the appendix.
Cancellations or returns are not possible.
Accessories
806202 IP65 base, red
807332.SV99
IQ8Alarm speech alarm, red - customized version
1
As 807322.SV99, but red.
When ordering, please note the "Ordering information for IQ8Quad and IQ8Alarm" and fill in ​
“Order form for individual combination of languages” printed in the appendix.
Costs for the recording of customer specific texts and/or tones can be obtained on request.
Cancellations or returns are not possible.
Accessories
806202 IP65 base, red
192
www.hls-austria.com
Alarm Devices
IQ8Alarm
1
IQ8Alarm - Combined Alarm and Speech Signaling Device
807224
2
IQ8Alarm combined alarm signaling device
1
Approval: VdS
3
Addressable, completely bus powered and short circuit / open circuit resistant alarm s​ ignaling device compliant with EN 54-3. Provides up to 20 different programmable ​signaling
tones including DIN tone in accordance with DIN 33404 Part 3 for acoustic and ​optical
alarm signaling. The volume can be set to 8 different levels. Its flat design enables ​
optimum adaptation to different interiors. It is made of shock and scratch resistant plastic. ​
Optionally, bases 806201 and 806202 with side cable entry, knock-outs and weatherproof
protection ​(IP65) can be installed.
4
5
Technical Data
Light intensity
Color
Specification
max. 24,4 Cd peak/ 4,1 Cd effective (red flash)
red, similar to RAL 3020
EN 54-3 acoustic signaling device
EN 54-17 isolators
6
Accessories
806202 IP65 base, red
807372
7
8
IQ8Alarm combined speech alarm
1
Approval: VdS
9
As 807224, but with speech alarm for powered loop connection.
Technical Data
Light intensity
Specification
10
max. 24,4 Cd peak/ 4,1 Cd effective (red flash)
EN 54-3 acoustic signaling device
EN 54-3 acoustic speech signaling device (Q2/2011)
EN 54-17 isolators
11
Programmed with 5 standard languages (DE/GB/FR/ES/IT).
Accessories
806202 IP65 base, red
12
13
14
15
193
Alarm Devices
807372.SV98
IQ8Alarm
IQ8Alarm combined speech alarm - special language
1
Approval: VdS
As 807372, but with individual selection of speech message languages. Max. recording
time per device is 169 seconds.
When ordering, please note the "Ordering information for IQ8Quad and IQ8Alarm" and fill in ​
“Order form for individual combination of languages” printed in the appendix.
Cancellations or returns are not possible.
Programmed with an individual selection of up to 5 sets of messages in national languages.
Accessories
806202 IP65 base, red
807372.SV99
IQ8Alarm combined speech alarm - customized version
1
Approval: VdS
As 807372, but with individual texts and/or sound tones. The max. recording time per
device is ​169 seconds.
When ordering, please note the "Ordering information for IQ8Quad and IQ8Alarm" and fill in ​
“Order form for individual combination of languages” printed in the appendix.
Costs for the recording of customer specific texts and/or tones can be obtained on request.
Cancellations or returns are not possible.
Programmed in accordance with customer specification.
Accessories
806202 IP65 base, red
194
www.hls-austria.com
Alarm Devices
IQ8Alarm
1
IQ8Alarm - Optical Alarm Signaling Devices
807212
2
IQ8Alarm optical alarm signaling device, amber
1
Approval: VdS
3
Addressable, completely bus powered and short circuit / open circuit resistant alarm s​ ignaling device for optical alarm signaling. Its flat and unobtrusive design enables ​optimum
adaptation to different interiors.
4
Technical Data
Light intensity
Color
max. 24 Cd peak/3,87 Cd effective
base: white, similar RAL 9010
cap: amber
5
806201 IP65 base, white
6
7
807213
8
IQ8Alarm optical alarm signaling device, transparent, blue, green
1
Approval: VdS
9
As 807212, but transparent, blue and green.
Technical Data
Light intensity
Color
10
transparent: max. 17,39 Cd peak/2,16 Cd effective
blue: max 5,06 Cd peak/0,62 Cd effective
green: max. 2,72 Cd peak/0,33 Cd effective
base: white, similar RAL 9010
cap: blue, green, transparent
11
806201 IP65 base, white
12
13
14
15
195
Alarm Devices
807214
IQ8Alarm
IQ8Alarm optical alarm signaling device, red
1
Approval: VdS
As 807212, but red.
Technical Data
Strength of light
Color
806202 IP65 base, red
196
www.hls-austria.com
max. 20.91 cd peak/3.41cd effective
base, cap: red, similar to RAL 3020
Alarm Devices
IQ8Alarm
1
Accessories
806201
2
Base IP65 for IQ8Alarm, white
1
White base for IQ8Alarm device to increase protection type. The base has side cable ​entry.
3
Technical Data
Type of protection
Color
IP65
white, similar to RAL 9010
4
For IP65 additional cable glands must be ordered separately.
5
806202
Base IP65 for IQ8Alarm, red
1
Red base for IQ8Alarm device to increase protection type. The base has side cable entry.
6
Technical Data
Type of protection
Color
IP65
red, similar to RAL 3020
7
For IP65 additional cable glands must be ordered separately.
8
850060
Special painting for IQ8Alarm
9
IQ8Alarm device is painted and delivered according to the required RAL color. For ​identical
colors, it is suggested to order a suitable number of additional pcs. for maintenance
purposes..
10
When ordering please specify:
- RAL code
- Glossy, semi-matt, matt finishing
767800
11
Mounting bracket for lintel installation
1
Mounting bracket for all bases/detectors of the IQ8Quad group, series 9x00 and ​for
IQ8Alarm & all alarm devices.
12
The distance between the mounting holes is 6 cm and the diameter is approx. 5 mm.
13
Technical Data
Material
Color
aluminum
white, similar to RAL 9010
14
Mounting bracket and installation material
15
197
Alarm Devices
Conventional
Audible Alarm Devices
766225
Sounder with low-profile base, red
1
Approval: VdS, LPCB
The alarm signalling device offers a selection of 32 acoustic signals including the DIN ​
German standard as well as additional country-specific acoustic signals.
The configuration is carried out via a five-pin DIL-switch. Up to two different acoustic ​
signals can be activated independently.
Technical Data
Features
• Flat design
• Suitable for 12 and 24 V DC operating voltage
• Low current consumption
• Adjustable volume
• Sound tone selection
• 32 tones available, 6 tones compliant with
EN 54-3
• Sounders syncronization
• Built-in diode for reverse polarity monitoring
Operating voltage
Quiescent current
Alarm current @ 12 V DC
Alarm current @ 24 V DC
Starting current
Sound level @ 24 V DC
Sound level @ 12 V DC
Ambient temperature
Type of protection
CE certificate
Specification
Housing
Color
Dimensions
9 ... 28 V DC
0 mA
approx. 7 mA for DIN-Tone, 3 to 16 mA for other tones
15 mA for DIN-Tone, 5 to 32 mA for other tones
approx. 32 mA
103 dB(A) for DIN-Tone, 100 to 112 dB(A) for other
96 dB(A) for DIN-Tone, 93 to 102 dB(A) for other tones
-25 °C ... 70 °C
IP54 and IP65 with 766237/766230
0832-CPD-0128
EN 54-3
ABS V0
red, similar to RAL 3001
Ø: 93 mm H: 63 mm
Ø: 93 mm H: 91 mm (incl. base 766237/38)
Suitable for using outside or in humid environments only with optional bases with side cable
entry (766237) via cable glands.
Shallow IP54 base is included.
Accessories
766237 IP65 base, red
766230 IP65 base, red
766226
Sounder with low-profile base, white
1
As 766225, but white.
Technical Data
Color
Accessories
766238 IP65 base, white
198
www.hls-austria.com
white, similar to RAL 9010
Alarm Devices
766237
Conventional
1
Base with side cable entry, red
1
For alarm sounder 766225, flashlights 766410, 766411, 766412, ​766413 and combined
alarm devices 766240, 766240.20 including rubber seal.
2
Technical Data
Type of protection
Color
Dimensions
IP65
red, similar to RAL 3001
Ø: 94 mm H: 47 mm
3
Rubber seal and two screws
4
IP65 protection level is only reached when side cable entry is made using cable glands (not
included).
766238
5
Base with side cable entry, white
1
As 766237, but white for sounder 766236 and flashlight 766414.
6
Technical Data
Color
white, similar to RAL 9003
7
8
766230
1
Base with side cable entry, red
9
For alarm sounder 766225, flashlights 766410, 766411, 766412, 766413 and combined
alarm devices 766240, 766240.20 including rubber seal.
Technical Data
Type of protection
Color
10
IP65
red, similar to RAL 3001
Rubber seal and two screws
11
IP65 protection level is only reached when side cable entry is made using cable glands (not
included).
12
766239
Sounder, red
13
1
Approval: LPSB
Alarm signaling device offers a selection of 32 signaling tones which can be selected via ​
DIL-switch. Volume control via potentiometer.
14
Technical Data
Operating voltage
Quiescent consumption @ 24 V DC
Alarm current @ 24 V DC
Sound level @ 24 V DC
Ambient temperature
Storage temperature
Type of protection
Housing
Color
Dimensions
CE Certificate
18 ... 28 V DC
0 mA
240 mA with DIN-tone
112 dB(A)
-10 °C ... 55 °C
-25 °C ... 70 °C
IP 21C
ABS
red, similar to RAL 3001
W: 108 mm H: 91 mm
0832-CPD-0141
15
199
Alarm Devices
766262
Conventional
Cover plate for 766261 signal base
1
For covering the connection when operated without detector.
Technical Data
Color
white, similar to RAL 9010
Cover plate and one screw
200
www.hls-austria.com
Alarm Devices
Conventional
1
Explosion-Proof
045040
2
Ex sounder DS10
1
Approval: VdS
3
Sounder is especially suitable for explosion endangered areas (zone 2 and 22). ​The robust
aluminum die-cast housing is resistant to chemicals and environmental influences. ​DS10
complies with the technical requirementsof DIN 33404 - 3 "hazard signals for ​workplaces".
4
Technical Data
Features
• 32 tone signals selectable
• ATEX approved
• 12 V / 24 V operating voltage
• Robust, IP67 die-cast aluminum housing
Ex-category
Explosion protection
Operating voltage
Current consumption @ 12 V DC
Current consumption @ 24 V DC
Sound level
Ambient temperature
Storage temperature
Air humidity
Type of protection
Material
Category
Color
Weight
Specification
Dimensions
ATEX certificate
CE certificate
3G/3D
II 3G Ex nA II T4, II 3D Ex tD A22 IP67 T135°C
10 ... 15 V DC or 19 ... 29 V DC
approx. 300 mA
approx. 420 mA
110 dB(A) ± 3 dB
-25 °C ... 55 °C
-40 °C ... 70 °C
≤ 90%
IP66/IP67
aluminum die cast
II 3GD
red, similar to RAL 3000
approx. 1.95 kg
EN 54-3
W: 150 mm H: 150 mm D: 143 mm
PDG 0301
0786-CPD-20005
5
6
7
8
According to ATEX certificate, DS10 can be used in zones 2 and 22.
9
766253
Ex horn, 12 V DC
1
Approval: VdS
10
This ex horn is especially suitable for application in explosion endangered areas at industrial work­places zones 1 and 2 and complies with the technical ​requirements of DIN 33404 3 standard. Robust aluminium die-cast housing is resistant to ​chemicals and environmental influences.
11
Technical Data
Features
• 32 tone signals selectable
• Quartz controlled sound synchronization
• ATEX approved
• LM6 aluminum die-cast housing
• Self-extinguishing aluminum cone, similar to UL ​
94 VO
Ex-category
Explosion protection
Operating voltage
Current consumption @ 12 V DC
Sound level
Ambient temperature
Storage temperature
Air humidity
Type of protection
Material
Color
Weight
Dimensions
ATEX certificate
12
2G
II 2G EEx d IIC T4
12 V DC
approx. 195 mA;
110 dB(A) ± 3 dB @ 1 m (depending on signaling tone)
-50 °C ... 55 °C
-50 °C ... 70 °C
≤ 90 %
IP67
aluminum die cast LM6
red, similar to RAL 3000
approx. 3.16 kg
Ø: 181 mm L: 263 mm
KEMA 99 ATEX 7906
13
14
15
201
Alarm Devices
Conventional
Optical Alarm Devices
766303
Flashing light, 12 V DC, amber
1
Technical Data
Operating voltage
Alarm current
Frequency of flash
Lighting energy
Ambient temperature
Storage temperature
Type of protection
Housing
Color
Weight
Dimensions
12 V DC
350 mA
approx. 1 Hz
approx. 4 J
-20 °C ... 50 °C
-25 °C ... 55 °C
IP54
ABS plastic
gray, similar to RAL 7035 (base)
approx. 360 g
Ø: 108 mm H: 133 mm
Wall bracket included
766304
Flashing light, 24 V DC, amber
1
As 766303, but 24 V DC operating voltage.
Technical Data
Operating voltage
Alarm current
24 V DC
250 mA
Wall bracket included
766305
Flashing light, 12 V DC, red
1
As 766303, but with red lens.
766306
Flashing light, 24 V DC, red
1
As 766304, but 24 V DC operating voltage and red lens.
766307
Flashing light, 12 V DC, green
1
As 766303, but with green lens.
766308
Flashing light, 24 V DC, green
1
As 766304, but 24 V DC operating voltage and green lens.
202
www.hls-austria.com
Alarm Devices
766410
Conventional
1
Optical alarm signaling device, red
1
Approval: VdS
2
Technical Data
Features
• Suitable for 12 and 24 V DC operating voltage
• Type A and B for indoor and outdoor operation
• Automatic flash syncronization
• Built-in diode for reverse polarity monitoring
Quiescent current
Operating voltage
Alarm current @ 12 V DC
Alarm current @ 24 V DC
Frequency of flash
Light intensity
Application temperature
Air humidity
Type of protection
Material
Weight
Dimensions
0 mA
9 ... 60 V DC
approx. 185 mA
approx. 88 mA
approx. 1 Hz
5 Cd
-25 °C ... 70 °C
< 93 % (non-condensing)
IP54, IP65 with 766230/37/38 socket
base ABS
lens PC
approx. 150 g
Ø: 94 mm H: 67 mm (incl. shallow base)
Ø: 94 mm H: 92 mm (incl. base 766230/37/38)
3
4
5
Shallow IP54 base in delivery included.
6
Suitable for using outside or in humid environments only with optional bases with side cable
entry (Part No. 766230/37/38) via cable glands.
7
Accessories
766237 IP65 base red
766230 IP65 base red
767800 Mounting bracket
766411
8
Optical alarm signaling device, amber
9
1
as 766410, but with amber color lens.
Technical Data
Light intensity
10
10 Cd
Accessories
766238 IP65 base white
767800 Mounting bracket
11
12
766412
Optical alarm signaling device, green
13
1
As 766410, but with green color lens.
Technical Data
Light intensity
14
10 Cd
Accessories
766238 IP65 base white
767800 Mounting bracket
15
203
Alarm Devices
766413
Conventional
Optical alarm signaling device, blue
1
As 766410, but with blue color lens.
Technical Data
Light intensity
7 Cd
Accessories
766238 IP65 base white
767800 Mounting bracket
766414
Optical alarm signaling device, transparent
1
As 766410, but with transparent color lens.
Technical Data
Light intensity
Accessories
766238 IP65 base white
767800 Mounting bracket
204
www.hls-austria.com
22 Cd
Alarm Devices
Conventional
1
Combined Alarm Devices
766240
2
Combined optical-acoustic alarm device, 12 V DC, red
1
Approval: VdS, CPCB
3
Combined sounder and flashlight for indoor and outdoor installation (with 766237/38/30).
Alarm sounder and flashing light may ​be activated separately. Floating tone going by 1 Hz
beat between 1200 and 500 Hz (DIN ​tone).
4
Technical Data
Features
• Automatic sounder and flashlight syncronization
• Separate activation of sounder and flashlight
possible
• Built-in diode for reverse polarity monitoring
Operating voltage
Quiescent current
Alarm current @ 12 V DC
Sound level @ 12 V DC
Frequency of flash
Lighting energy
Light intensity
Ambient temperature
Storage temperature
Air humidity
Type of protection
Material
Color
Weight
Dimensions
CE certificate
Specification
9 ... 15 V DC
0 mA
approx. 101 mA (flash lamp + sounder for DIN tone)
91 dB for DIN tone
approx. 1 Hz
0.7 J
10 cd
-10 °C ... 55 °C
-15 °C ... 60 °C
< 93 % (non-condensing)
IP54, IP65 (with 766237/38/30)
ABS plastic (UV-stabilised)
red, similar to RAL 3001
approx. 350 g
Ø: 93 mm H: 92 mm
Ø: 93 mm H: 120 mm (incl. base)
0786-CPD-20005
EN 54-3
5
6
7
8
9
Shallow IP54 base in delivery included.
Outdoor instalation possible only with IP base (Part No. 766237/30) with additional cable
glands.
10
Accessories
766237 IP65 base red
766230 IP65 base red
767800 Mounting bracket
11
766240.20
Combined optical-acoustic alarm device, 24 V DC, red
1
Approval: VdS, CPCB
12
As 766240, but with 32 different alarm tones which can be selected via DIL switch. Alarm
sounder and flashing ​light may be activated separately.
13
Technical Data
Operating voltage
Alarm current @ 24 V DC
Sound level @ 24 V DC
Dimensions
Features
14
18 ... 28 V DC
approx. 66 mA (flashlight + sounder) for DIN tone,
52 to 85 mA for all tones
98 dB for DIN tone, 83 to 110 dB(A) for all tones
Ø: 93 mm H: 120 mm (incl. deep base)
15
Deep base (Part No. 766237) IP65 in delivery included.
• 32 selectable tones, 6 tones compliant with
EN 54-3
• Adjustable sound volume
205
Alarm Devices
766240.30
Conventional
Combined optical-acoustic alarm device, 24 V DC, red
As 766240.20, but with shallow base.
1
Technical Data
Dimensions
Ø: 93 mm H: 92 mm (incl. shallow base)
Deep base (Part No. 766237) IP65 in delivery included.
766240.10
Combined optical-acoustic alarm device, 24 V DC, red, Asserta type
Asserta sounder beacon is designed to cope with harsh environments requiring IP66
protection level and is compliant with EN54-3. 32 different alarm tones can be selected.
High volume alarm ​sounder and very strong flashing light may be activated separately.
1
Technical Data
Operating voltage
Quiscent current
Alarm current @ 24 V DC
Features
• 32 alarm tones selectable
• Volume regulation
• Separate activation of sounder and flashlight
possible
• Built-in diode for reverse polarity monitoring
Lighting energy
Frequency of flash
Sound level @ 24 V DC
Volume regulation
Ambient temperature
Type of protection
Material
Color
Weight
Dimensions
CE certificate
9 ... 60 V DC
0 mA
approx.230 mA (lamp),
approx. 31 mA (sounder) for DIN tone, 14 to 41 mA for
all tones
2,5 J (flashlight)
1 Hz
106 ... 111 dB (A), 109 dB (A) for DIN tone
10 dB (A)
-25 °C ... 75 °C
IP66
ABS/PC
red, similar to RAL 3001
approx. 0,8 kg
W: 174 mm H: 165 mm D: 132 mm
0832-CPD-0570
IP66 protection rating requires use of cable glands for cable entry (not included).
206
www.hls-austria.com
Alarm Devices
Features
• Shapely, light-weight and compact design
• Prism with all around 180 ° visible LEDs with a ​
wide area of ilumination and high on/off contrast
• Connection terminal max. 1,5 mm²
Remote Indicators
1
These indicators are used primarily for signaling alarms from smoke detectors installed
above ​suspended ceilings, between floors or in other inaccessible locations. The indicators
have ​an elegant plastic housing with a clearly visible illuminated field. It comprises two
parts - ​the base which is installed onto a wall or ceiling and the lid which is fitted to the
base with a ​clip.
2
Technical Data
Ambient temperature
Storage temperature
Air humidity
Type of protection
Housing
Color
Weight
Dimensions
-20 °C ... 70 °C
-35 °C ... 85 °C
< 95 % (non-condensing)
IP50
ABS plastic
white, similar to RAL 9010
approx. 60 g
W: 85 mm H: 82 mm D: 27 mm
3
4
Cable length from the remote indicator to detector base or voltage supply max. 100 m.
781804
5
Remote indicator for conventional detector series 9000, red lens
6
1
Red prism is illuminated by 4 pulsed LEDs to optimize energy consumption.
Connection by 3/4 wire cable to detector socket.
Technical Data
Operating voltage
Quiescent current @ 12 V DC
Alarm current
Frequency of flash
Alarm indicator
7
6 ... 12 V DC
approx. 0.005 mA
approx. 9 mA
approx. 1.5 Hz
4 red LEDs
8
Operation only with conventional automatic fire detectors series 9000 and
standard detector base 781590.
Features
• 4 pulsed LEDs
• Power-saving compact indicator
• Viewing angle 180°
781814
9
- Adapter module (Part No. 781487) required
- max. 3 indicators per detector / max. 3 detectors per indicator
- max. 60 remote indicators per zone (with max. 20 detectors)
- for each additional detector, decrease 3 remote indicators
(e.g. 21 detectors -> max. 57 remote indicators 30 detectors -> max. 30 remote indicators).
10
Remote indicator for detector series 9000, 9200 and IQ8Quad, red lens
11
1
Red prism is continuously or pulsed illuminated by 3 LEDs.
Connection by 2-wire cable to detector socket. The voltage supply mode can be selected by
jumper settings.
12
Technical Data
Operating voltage
Alarm current @ 1,8 V DC
Alarm indicator
1.8 ... 3 V DC (mode 1)
8 ... 15 V DC (mode 2)
approx. 9 mA
3 red LEDs
13
Detectors series 9000
Features
• 3 continuously or pulsed LEDs
• Power-saving compact indicator
• Viewing angle 180°
• Default activation by detector connected to
• Configurable activation by any system event
programmable via tools8000 software
850059
14
- Standard detector base 781590 and adapter module 781487 required
- Max. 2 detectors per indicator / max. 2 indicators per detector
- Remote indicator is lit continuously when activated.
15
Detectors series 9200 / IQ8Quad
- Standard detector base 781590 or base 801593 required for series 9200 detectors
- Standard base 805590 required for series IQ8Quad
- 1 remote indicator per detector
- Indicator flashes when activated (Pulse frequency approx.1 Hz)
Special painting remote indicator 781814
Remote indicator is painted and delivered according to the required RAL color. For ​identical
colors, it is suggested to order a suitable number of additional pieces for maintenance
purposes.
When ordering please specify:
- RAL code
- Glossy, semi-matt, matt finishing
207
Alarm Devices
801824
Remote Indicators
Remote indicator for detector series 9200 and IQ8Quad, red lens
1
Red prism is illuminated by 4 pulsed LEDs for operation on esserbus and esserbus-PLus ​
to optimize energy consumption.
Build-in current consumption stabilizator and energy storing capacitor for elimination of
current peaks on esserbus/PLus loop and for increasing flash intensity.
Technical Data
Features
• 4 pulsed LEDs
• Ultra power-saving compact indicator
• Viewing angle 180°
• Default activation by detector connected to
• Configurable activation by any system event
programmable via tools8000 software
850058
Operating voltage
Quiescent current
Alarm current
Frequency of flash
Alarm indicator
8 ... 42 V DC
approx. 0.007 mA
approx. 150 µA
approx. 1.5 Hz
4 red LEDs
Detectors series 9200 / IQ8Quad
• Standard detector base Part. No. 781590 or base Part. No. 801593 required for series 9200 ​
detectors
• Standard base Part. No. 805590 required for series IQ8Quad
• max. 3 indicators per detector
• max. 103 remote indicators per loop
Special painting remote indicator 801824
Remote indicator is painted and delivered according to the required RAL color. For ​identical
colors, it is suggested to order a suitable number of additional pieces for maintenance
purposes.
When ordering please specify:
- RAL code
- Glossy, semi-matt, matt finishing
801825
Remote indicator for detector series 9200 and IQ8Quad, blue lens
1
Blue prism is illuminated by 4 pulsed LEDs to optimise energy consumption. Connec­tion
via 3/4-wire cable to detector socket. For special applications such as indication of assaults
on jailers in ​any prison cell of penitentiaries and correctional facilities.
Technical Data
Operating voltage
Quiescent current
Alarm current
Frequency of flash
Alarm indicator
Features
• 4 pulsed LEDs
• Power-saving compact indicator
• Viewing angle 180°
208
www.hls-austria.com
14 ... 42 V DC
approx. 0.007 mA
approx. 150 μA
approx. 1.5 Hz
4 red LEDs
Automatic Fire Detectors series 9200 / IQ8Quad
• Standard detector base Part. No. 781590 or base Part. No. 801593 required for series 9200 ​
detectors
• Standard detector base Part. No. 805590 required for series IQ8Quad detectors
• Max. 3 indicators per detector / max. 2 detectors per indicator
• Max. 103 remote indicators per analog loop
• Do not connect remote indicator to detector base Part. No. 781593
• Cable length to detector base or voltage supply max. 100 m
1
2
3
4
5
6
7
8
9
10
Door Release System
Automatic Door Systems
210-212
Door Holding Devices
213-217
Triggering Devices
218-219
11
12
13
14
15
209
Door Release System
Automatic Door Systems
Automatic door closing systems for the demarcation of buildings and objects in closed fire ​
compartments for the protection of people and valuables in case of fire.
Automatic door systems consist of triggering devices and locking devices.
In the event of fire, signals created by automatic triggering device cause a ​release of
locking device. Actuation by the manual triggering device also leads to ​release of locking
device.
Fire doors close and prevent the spreading of fires and of any present smoke to ​bordering
areas in a building. This way, fire and dangerous fire aerosols are contained a​ nd human life
as well as valuables are protected.
Locking device consists of e.g. a clamping magnet with corresponding anchor plate and/​or
of an automatic door closer. Triggering device consists of a controller, fire detector and
release key pushbutton (manual triggering device).
In terms of building directives in Germany, automatic door systems are subject to approval
by Deutschen ​Institut for Bautechnik in Berlin and need a system authorization (for this,
see certificates ​of approval from the DIBt).
Arrester system for fire barriers
Authorization number: Z-6.5-430
System SAL 9000 FSA Smoke Heat Ventilation Module
Authorization number: Z.-6.5-1457
System 8000 FSA system authorization
Authorization number: Z-6.5-1764
System IQ8FSA 8619 system authorization
Authorization number: Z-6.5-1759
System 8000 FSA Plus system authorization
Authorization number: Z-6.5-1808
For stand-alone operation of FSA transponder (Part No. 808619.10) 9000 series detectors (Part
No. 761162, 761262, 761362) can be used as arrester system detectors.
210
www.hls-austria.com
Door Release System
Automatic Door Systems
1
Connection Examples
2
3
4
5
6
Release
pushbutton
7
8
9
10
11
12
13
14
Release
pushbutton
Release
pushbutton
15
211
Door Release System
Release
pushbutton
Release
pushbutton
212
www.hls-austria.com
Automatic Door Systems
Door Release System
Door Holding Devices
1
Holding Magnets with 400 N Holding Force
The door holding magnets from this product line are generally vacuum cast and feature ​
IP65 protection class by the basic device. The magnets are quality-controlled and are ​
subjected to sampling tests twice per year by the VdS. In addition, all dimensions are in ​
accordance with European specifications and tested in compliance with the EN1155.
2
3
960120
Door magnet with release button incl. flexible anchor, 400 N
1
Release button changeable to the left or right from the base. Cable entry is ​possible from
behind the unit, as well as through the base, left or right side using ​included grommets.
In combination with angled mounting plates the unit can be installed to either floor or wall.
4
Integrated reverse-polarity protection diode and spark supressing diode.
5
Technical Data
Operating voltage
Power consumption
Type of protection
Dimensions
CE certificate
24 V DC
1.6 W
IP54 (magnet); IP42 (connection)
W: 85 mm H: 110 mm D: 38 mm
0786-CPD-20435
6
7
960121
Door magnet with distance pipe incl. flexible anchor, 400 N, 175 mm
1
Approval: VdS
8
Magnet rotary head is fully rotational and is thus suitable for both floor ​and wall installations. Customer may shorten distance pipe if necessary.
Integrated reverse-polarity protection diode and spark supressing diode.
Manual release button on pipe available.
Wall distance: 175 mm
Floor distance: 150 mm
9
10
Technical Data
Operating voltage
Power consumption
Type of protection
Dimensions
CE certificate
960122
24 V DC
1.6 W
IP54 (magnet); IP42 (connection)
W: 90 mm H: 80 mm Distance: 150/175 mm
0786-CPD-20435
11
12
Door magnet with distance pipe incl. flexible anchor, 400 N, 325 mm
1
As 960121, but with wall distance 325 mm or floor distance 300 mm.
13
Technical Data
Dimensions
960123
W: 90 mm H: 80 mm Distance: 300/325 mm
14
Door magnet with distance pipe incl. flexible anchor, 400 N, 475 mm
1
As 960121, but with wall distance 475 mm or floor distance 450 mm.
15
Technical Data
Dimensions
960124
W: 90 mm H: 80 mm Distance: 450/475 mm
Door magnet w/o release button incl. flexible anchor, 400 N
1
Version with terminal clamp and installation plate.
Integrated reverse-polarity protection diode and spark supressing diode.
Suitable for wall installation.
Technical Data
Operating voltage
Power consumption
Type of protection
Dimensions
CE certificate
24 V DC
1.6 W
IP54 (magnet); IP42 (connection)
W: 55 mm H: 55 mm D: 33 mm
0786-CPD-20435
213
Door Release System
Door Holding Devices
Holding Magnets with 490 N Holding Force
960100
Wall-mounted door magnet with release button, 490 N
1
Wall-mounted direct current door magnet.
Technical Data
Operating voltage
Power consumption
Dimensions
CE certificate
24 V DC
1.5 W
W: 85 mm H: 120 mm D: 38 mm
0786-CPD-20249
Delivery without anchorplate
960101
Floor-mounted door magnet with release button, 490 N
1
Approval: VdS
Floor-mounted door magnet made of plastic material with 30% glass fiber content.
Integrated reverse-polarity protection diode and spark supressing diode.
Technical Data
Operating voltage
Power consumption
Type of protection
Material
Dimensions
CE certificate
960102
24 V DC
1.5 W
IP65
PA6, 30% GF
W: 121 mm H: 121 mm D: 86 mm
0786-CPD-20249
Rotary door magnet with release button, 490 N
1
Approval: VdS
Plastic rotary head of the door magnet is fully rotational and is thus ​suitable for floor,
ceiling and wall installations.
Integrated reverse-polarity protection diode and spark supressing diode.
Wall distance: 175 mm
Floor/ceiling distance: 150 mm
Technical Data
Operating voltage
Power consumption
Type of protection
Dimensions
CE certificate
960103
24 V DC
1.5 W
IP65
W: 70 mm H: 70 mm Distance: 150/175 mm
0786-CPD-20249
Door magnet w/o release button, 490 N
1
Door magnet for wall-mounting with free stranded wire.
Integrated reverse-polarity protection diode and spark supressing diode.
Technical Data
Operating voltage
Power consumption
Type of protection
Dimensions
CE certificate
214
www.hls-austria.com
24 V DC
1.5 W
IP65
W: 55 mm H: 55 mm D: 5 mm
0786-CPD-20249
Door Release System
Door Holding Devices
1
Explosion-Proof
767145
Ex door magnet, 588 N
2
1
Approval: VdS, TÜV ATEX
Explosion-proof and encapsulated holding magnet for explosion endangered areas.
Wall-mounted with cable entry via cable gland.
3
Technical Data
Operating voltage
Power consumption
Holding force
Ambient temperature
Ex-category
Explosion protection
Type of protection
Dimentions
EC-type examination certificate
24 V DC
3W
588 N
0 °C ... 35 °C
II 2G (gas) and 2D (dust)
EExme II T6 (gas) and T73°C IP6X (dust)
IP56
W: 130 mm H: 117 mm D: 106 mm
TÜV01 ATEX 1778 X
4
5
6
Delivery without anchor plate.
on demand
7
Approved anchor plates must be used in EX zones.
1
767153
8
Ex door magnet, 1568 N
As 767145, but with 1568 N holding force.
9
Technical Data
Holding force
1568 N
10
11
12
13
14
15
215
Door Release System
960127
Door Holding Devices
Wall and floor swivel brackt for door magnet 960120, angled, 150 mm
1
This swivel bracket is specially intended for use with 960120 door magnet and thus allows
floor or wall installa­tion by means of distance pipe.
960128
Wall and floor swivel bracket for door magnet 960120, angled, 300 mm
1
As 960127, but with 300 mm pipe length.
960129
Floor-mounted brackt for door magnet 960120
1
This brackt is especially intended for 960120 door magnet. Thus a parallel door installation
is possible. Magnet ​can either be installed within the side panels (to protect from vandalism) or adjacent to the ​side panels (standard). Due to the increased gauge of steel used,
this base is suitable for ​heavy use (schools etc).
216
www.hls-austria.com
Door Release System
Door Holding Devices
1
Anchor Plates
960109
Fixed anchor plate for door magnets 960100-960103
2
The door-mounted anchor plate electromagnetically binds the magnetic clamp with the ​
door. The anchor plate is flexible mounted on the mounting plate and thus can balance out ​
any oblique angles (max. 5°). The diameter of the plate is larger that the diameter of the ​
magnet. The holding surface is grounded and protected against corrosion with zinc ​
coating.
3
Technical Data
4
1
Dimensions
960110
Ø: 55 mm W: 55 mm H: 55 mm D: 18 mm
5
Flexible anchor plate for door magnets 960100-960103
1
The flexible anchor plate is designed for doors with an angle. The anchor plate is 60° ​
adjustable and fixable in each direction through an articulated joint. The surface is ​
grounded and protected against corrosion.
6
Technical Data
Dimensions
7
Ø: 55 mm W: 55 mm H: 55 mm D: 50 mm
8
Door Closer
9
767123
Door closer, hold-open size 2-5
1
10
Slide bar with integrated, electromechanical hold-open device. Opening angle (80° to 130°) ​
and adjustable release force.
Technical Data
Operating voltage
Power consumption
Color
Weight
Dimensions
11
24 V DC
1.4 W
silver
approx. 3.5 kg
L: 275 mm W: 53 mm H: 60 mm
12
DIBt-approved for:
Smoke alarm switch RAS 2103: Z-6.5-1457
Door control systems for fire shutters: Z-6.5-430
Fire alarm system 8000 FSA: Z-6.5-1764
FSA transponder: Z-6.5-1759
13
on request
14
15
217
Door Release System
Triggering Devices
Power Supply Units for Door Release System
765612
Power supply unit for automatic door release systems, 12 V, 3 A
1
Surface mount housing for fire door release systems.
Technical Data
Rated voltage
Rated frequency
Output voltage
Output current
Ambient temperature
Storage temperature
Air humidity
Type of protection
Housing
Color
Weight
Dimensions
765624
230 V AC/115 V AC
50 ... 60 Hz
12 V DC
max. 3 A
-10 °C ... 40 °C
-20 °C ... 85 °C
≤ 95 % (without condensation)
IP20
ABS plastic
white, similar to RAL 9010
approx. 800 g
W: 195 mm H: 140 mm D: 70 mm
Power supply unit for automatic door release systems, 24 V, 1.5 A
1
As 765612, but with 24 Volt.
Technical Data
Output voltage
Output current
218
www.hls-austria.com
24 V DC
max 1.5 A
Door Release System
Triggering Devices
1
Release Pushbuttons
767813.10
2
Surface mount release pushbutton for automatic door release system, ​German
1
Surface mount release key for manual actuation of locking devices with double rocker ​
switch insert.
3
Technical Data
Contact load
Type of protection
Housing
Color
Weight
250 V AC/10 A
IP44
ABS plastic
gray, similar to RAL 7035
approx. 120 g
4
5
767814.10
Flush mount release pushbutton for automatic door release system, ​German
6
1
Flush mount release pushbutton for manual actuation of locking devices with double rocker
switch ​insert.
7
Technical Data
Contact load
Type of protection
Housing
Color
Weight
796349
250 V AC/10 A
IP44
ABS plastic
white
approx. 95 g
8
9
Label for release pushbutton
1
Red sticker label for release pushbutton 767813 and 767814.
10
10 pcs
11
12
13
14
15
219
Notes
220
www.hls-austria.com
1
2
3
4
5
6
7
8
9
10
Installation & Service
Installation Accessories
222-228
Housings
229-231
Services
232
11
12
13
14
15
221
Installation & Service
Installation Accessories
Surge Protection
764730
OVP module for TTY interfaces and standard detector zones
Approval: UL, VdS
1
Overvoltage protection module as 4-pin, rail-mounted device (764757 base module
required).
Space-saving, compact surge protector module for the protection of 2-wire ​symmetrical
interfaces with electrical isolation.
Technical Data
Rated voltage
Rated current
max. cont. operating voltage a.c.
max. cont. operating voltage d.c.
Nom. discharge current (80/20)/line
Total nom. discharge current
Total lightning imp. current (10/350)
Lightning imp. current (10/350)/line
Ambient temperature
Type of protection
24 V
1 A @ 45 °C
23.3 V AC
33 V DC
10 kA
20 kA
10 kA
2.5 kA
-40 °C ... 80 °C
IP20
Low resistance ground connection is a must for proper surge protection functioning.
Accessories
764737 Base for overvoltage protection module
764731
OVP module for essernet and RS-485 interfaces
Approval: UL
1
Space-saving compact surge protector with LifeCheck for the protection of 2-wire radiofrequency bus systems, with either direct or indirect shield grounding.
Technical Data
Rated voltage
Rated current
max. cont. operating voltage a.c.
max. cont. operating voltage d.c.
Nom. discharge current (80/20)/line
Total nom. discharge current
Total lightning imp. current (10/350)
Lightning imp. current (10/350)/line
Ambient temperature
Type of protection
5V
1 A @ 45 °C
4.2 V AC
6 V DC
10 kA
20 kA
9 kA
2.5 kA
-40 °C ... 80 °C
IP20
Accessories
764737 Base for overvoltage protection module
Low resistance ground connection is a must for proper surge protection functioning.
764732
OVP module including base for 230 V power supply line
Approval: UL, VdS
1
Two-pin surge protector comprising base element and protection module, with ​potentialfree telecommunications contact for independent fault forwarding.
Technical Data
Rated voltage
max. cont. operating voltage a.c.
max. cont. operating voltage d.c.
Nominal load current a.c.
Total discharge current (8/20) [L+N-PE]
Combined impulse
Combined impulse [L+N-PE]
Voltage protection level [L/N-PE]
Voltage protection level [L-N]
Response time [L/N-PE]
Response time [L-N]
Ambient temperature
Type of protection
230 V AC
255 V AC
255 V DC
25 A
5 kA
6 kV
10 kV
≤ 1500 V
≤ 1250 V
≤ 100 ns
≤ 25 ns
-40 °C ... 80 °C
IP20
Base element and connected protection module
Low resistance ground connection is a must for proper surge protection functioning.
222
www.hls-austria.com
Installation & Service
764733
Installation Accessories
1
OVP module for esserbus / esserbus-PLUS loop
Approval: UL, VdS
1
Space-saving compact surge protector module for protection of 2-wire ​symmetrical interfaces with electrical isolation.
Two overvoltage protection module of this type is required for each loop in places of
exiting/entering the building.
2
3
Technical Data
Rated voltage
Rated current
max. cont. operating voltage a.c.
max. cont. operating voltage d.c.
Nom. discharge current (80/20)/line
Total nom. discharge current
Total lightning imp. current (10/350)
Lightning imp. current (10/350)/line
Ambient temperature
Type of protection
48 V
1 A @ 45 °C
38.1 V AC
54 V DC
10 kA
20 kA
10 kA
2.5 kA
-40 °C ... 80 °C
IP20
4
5
Low resistance ground connection is a must for proper surge protection functioning.
6
Accessories
764737 Base for overvoltage protection module
764734
1
7
OVP module for analog telephone lines
Space-saving compact surge protector module for the protection of 1-wire pair of ​symmetrical interfaces with electrical isolation.
8
Technical Data
Rated voltage
Rated current
max. cont. operating voltage a.c.
max. cont. operating voltage d.c.
Nom. discharge current (80/20)/line
Total nom. discharge current
Total lightning imp. current (10/350)
Lightning imp. current (10/350)/line
Ambient temperature
Type of protection
180 V
0.75 A @ 45 °C
127 V AC
180 V DC
10 kA
20 kA
5 kA
2.5 kA
-40 °C ... 80 °C
IP20
9
10
11
Low resistance ground connection is a must for proper surge protection functioning.
Accessories
12
764737 Base for overvoltage protection module
764735
1
OVP module for ISDN telephone lines
13
For ISDN S0 bus with RJ45 connections.
The additional screw terminal connection on the protected output enables a double wiring ​
of the S0 bus (distribution function).
14
Technical Data
Rated voltage
Rated current
max. cont. operating voltage d.c.
Nom. discharge current (80/20)/line
Total nom. discharge current
Ambient temperature
Type of protection
5V
0.2 A
7.5 V DC
2.5 kA
10 kA
-40 °C ... 80 °C
IP10
15
No base is required for this OVP module.
Low resistance ground connection is a must for proper surge protection functioning.
223
Installation & Service
764736
Installation Accessories
OVP module for control outputs
Power-coordinated compact surge protector for the protection of ungrounded DC power ​
supplies for mounting-rail installation.
Protection of monitored and potential-free control outputs up to 36 volts.
1
Technical Data
Rated voltage
Rated current
max. cont. operating voltage d.c.
Nom. discharge current (80/20)/line
Total nom. discharge current
Total lightning imp. current (10/350)
Lightning imp. current (10/350)/line
Ambient temperature
Type of protection
36 V
7 A @ 40 °C
45 V DC
10 kA
20 kA
5 kA
2.5 kA
-40 °C ... 80 °C
IP20
No base is required for this OVP module..
Low resistance ground connection is a must for proper surge protection functioning.
764737
Base module for OVP modules
Approval: UL, VdS
Base part as very space-saving, 4-pin, universal feed-through terminal to accommodate t​he
surge protector module without signal interruption.
The secure grounding of the surge protector module is established via the mounting rail ​
support base by means of a snap-on attachment.
As no components of the protection circuit are located in the base part, maintenance work ​
is limited to the protection modules.
1
Technical Data
Ambient temperature
Type of protection
-40 °C ... 80 °C
IP20
Tool-free mounting on 35 mm installation rails.
970300
Surge protection module for Line heat detector LWM-1 (761290)
1
The surge protection device features compact housing, proven reliable hybrid circuitry,
simple installation and optional ​‘loop disconnect’ (a feature which allows commissioning
and maintenance to be carried ​out without removal of the surge protection device). Simple
manual operation clamps secure the module onto 35 mm installation rail, which ​automatically provides the essential high-integrity earth connection.
Features
• Range of ATEX Certified, intrinsically safe surge ​
•
•
•
•
•
224
protectors
Ultra-slim space saving design; easy installation
Multistage hybrid protection circuitry - 20 kA ​
maximum surge current
Range of voltage ratings - to suit all process I/O ​
applications
Low resistance version
Standard: EN 50014:1997, EN 50020:2002, EN ​
50284:1999
www.hls-austria.com
Technical Data
Ambient temperature
Storage temperature
Weight
-40 °C ... 80 °C
-10 °C ... 80 °C
approx. 70 g
To be used in conjunction with 970301 Ex-I terminal box.
One LWM-1 sensor cable is a 2-pair cable, which requires 2 surge protection modules
761270 for both pairs.
Installation & Service
Installation Accessories
1
Interface Converters
764852
2
Converter RS 232 / RS 485
1
For converting serial interface from RS 232 to RS 485 and vice versa. Suitable for installationrail ​mounting.
3
Technical Data
Operating voltage
Current consumption @ 12 V DC
Housing
Weight
Dimensions
Features
• RS485 2 and 4 wire compatible
• RS485 automatic mode
• No re-configuration of transmission parameters ​
12 ... 24 V DC /AC
approx. 85 mA
plastic small-design housing
approx. 500 g (incl. power supply)
W: 105 mm H: 75 mm D: 22 mm
4
5
1 x RS232/RS485 converter
1 x power supply unit
6
required
• Min. 1 kV electrical isolation
• Top hat rail housing according to DIN EN 50022-​
35
• Suitable as "non-intelligent" converter for RS485
field buses (e.g. profibus, CS31, etc.) <> ​RS232
764855
7
8
Converter RS 232 / TTY
1
When using this converter as serial communication transmitter for longer distances a
printer ​with a serial or parallel interface or a fire alarm panel or an intruder alarm panel can
be ​operated at a distance of up to 1000 m from the management system.
9
Please note that two RS 232 / TTY converters are required for each serial (RS 232).
Features
10
1 x line extension application RS232/TTY converter
1 x serial connecting plug
1 x parallel connection plug
1 x power supply unit
11
• RS-232 data transmission speed rate up to 128
kbps
12
• TX, RX Active/Passive selectable
• 20 or 60 mA selectable
• DTE/DCE device setting selectable
• TD/RD LED indicators
• Power LED indicator
13
14
15
225
Installation & Service
Installation Accessories
Accessories
767510
Control relay for top-hat rail mounting
1
Technical Data
Operating voltage
Relay contact load
Ambient temperature
788602
12 V DC
250 V AC/DC, 6 A
-20 °C ... 55 °C
Top-hat rail
1
Technical Data
Dimensions
L: 400 mm
Mounting kit
788652
Installation rail for FACP 8000 C/M and IQ8Control C/M housing
1
The top hat rail installation kit can be retrofitted into the IQ8Control unit housing. The hat ​
rail is fitted to the mounting board via two screws. A maximum of two 788603.10 transponder ​housings (option) can be mounted to the 788652 installation rail.
Technical Data
Dimensions
L: 35 mm W: 175 mm (standard-snap-on installation ​
rail)
Installation rail and accessories
Application example
788603.10
Transponder housing for top-hat installation rail
1
For snap-on mounting on installation rail of esserbus transponders resp. with 82 x 72 mm
PCB size. ​Angled cable entry.
Technical Data
Material
Color
1x UM-profile and 2x side panels
Application example
226
www.hls-austria.com
plastic
green
Installation & Service
788605
Installation Accessories
1
Mounting kit
1
Mounting kit required for mounting esserbus transponders in extension housings.
2
4 x spacer bolts and 2 x fixing screws
3
4
057633
Installation frame for transmission units and transponders
1
Installation frame specially designed for 8000C/M and IQ8Control C/M fire alarm panels ​
(IQ8Control C only with extension housing).
5
Technical Data
Dimensions
W: 280 mm H: 130 mm D: 25 mm
6
1 x Installation frame, 1 x Insulation foil and installation material
7
8
9
10
11
12
Application example
704147
Cable gland M12 with nut
13
1
Polyamide cable gland to increase the protection level of cable entry in device housing.
Technical Data
Ambient temperature
Type of protection
Material
Color
Cable diameter
704148
-20 °C ... 95 °C
IP67
Polyamide
gray
3 ... 6.5 mm
14
15
Cable gland M16 with nut
1
Polyamide cable gland to increase the protection level of cable entry in device housing.
Technical Data
Ambient temperature
Type of protection
Material
Color
Cable diameter
-20 °C ... 95 °C
IP67
Polyamide
gray
5 ... 8 mm
227
Installation & Service
050510
Installation Accessories
Mains interference suppression filter type 2VK3
1
Mains interference suppression filter is intended for later installation in all mains-oper­ated
devices in which problems due to HF disturbances in mains may appear.
Technical Data
Rated voltage
Rated current
Rated frequency
Ambient temperature
Dimensions
115 V-250 V AC
2A
50 ... 60 Hz
-10 °C ... 40 °C
W: 52.6 mm H: 46 mm D: 23.1 mm (without flange)
Mains interference suppression filter and terminal block
070450
Additional relay 12V DC
1
Small PCB with relay, connection terminals, two changeover contacts.
382040
8-fuse card
1
Approval: VdS
Fuse card with 8 x 0.5 A fuses for individual power supply protection of each area, zone ​
and device. It can be used with all Esser control panels and power supply units.
Technical Data
Contact load
Connection terminal
Ambient temperature
Storage temperature
Air humidity
Weight
Dimensions
30 V DC / 1 A
0,6 mm to max. 1,5 mm²
-5 °C ... 50 °C
-25 °C ... 75 °C
≤ 95 % (without condensation)
approx. 85 g
W: 65 mm H: 72 mm D: 15 mm
Installation possible in housings: Part No. ​788600, 788601, 788650, 788650.10, 788651, ​
788651.10, 788603 and 788603.10
228
www.hls-austria.com
Installation & Service
Housings
1
Housings
788600
2
Surface-mount housing, gray
1
Standard housing for esserbus transponders, voltage distributer card 382030 and DC/DC
converters 781335, 781336, 781337.
3
The following esserbus transponder types can be installed inside:
- 2 esserbus transponders: 808613.10, 808613.301, 808614.10, 808622, 808623,
808323.10, 808619.10
- 1 esserbus transponders: 808610.40, 808611.10, 808630.10, 808631.10
4
Technical Data
Type of protection
Material
Color
Dimensions
788601
IP40
ABS
gray, similar to RAL 7035
W: 189 mm H: 131 mm D: 47 mm
5
6
Flush-mount housing, gray
1
As 788600, but as flush-mount version.
7
Technical Data
Type of protection
Material
Color
Dimensions
IP40
ABS
gray, similar to RAL 7035
W: 189 mm H: 131 mm D: 47 mm
W: 207 mm H: 149 mm (cover)
8
9
788650.10
Surface-mount housing, white
1
As 788600, but white.
10
11
12
788651.10
Flush-mount housing, white
13
1
As 788601, but white.
14
15
229
Installation & Service
788655
Housings
High IP housing base
1
High IP housing base for extreme environmental conditions.
Technical Data
Type of protection
IP55
Accessory for FCT transponders and transponder in 788656 housing. Cable entry requires use of
cable glands 704147, 704148.
788656
High IP housing
1
Housing for FCT transponder. Can also be used for other esserbus transponder to increase
IP rating in connection with 788655.
Technical Data
Type of protection
IP55
Housing + front cover
788655 base must be ordered separatelly for IP55 protection.
230
www.hls-austria.com
Installation & Service
788030
Housings
Fire protection housing F30 RO
1
Fire protection cabinet allows to install a fire alarm control panel s​ eries IQ8Control and
FlexES Control in accordance with MLAR and LAR requirements of the different federal ​
states. The duration of the functional integrity of the electrical security and safety systems
must account for at least 30 minutes for:
2
- fire detection systems including the corresponding transmission systems
- systems that alarm and broadcast directives to visitors and employees, when these ​
systems must be operational in cases of fire.
3
1
Features
• Fire resistance F30, certified in accordance with ​
DIN 4102 part 2
• Functional integrity of over 30 minutes, in accord­
ance with DIN 4102 part 12
• Fire load insulation of over 30 minutes in accord­
ance with DIN 4102 part 11
• Protection type conforming IP41
• Smoke-proof
• Surface mounted
• Integrated mounting rail system for FACP IQ8Con­
•
•
•
•
•
•
•
trol / FlexES Control
Locking via pivoting lever without locking cylinder
Cable sealing for bundle inlet above
Push rod door fastener with 2 point interlock
Mounting straps
Material surface coating A2 non-​combustible in
accordance with DIN 4102 part 1
Colour light grey (other colours available for an ​
additional charge)
Ventilation system includes active ventilation via
top fans and ​thermo-regulated control
Fire Alarm Control Panel IQ8Control C/M and FlexES Control required by building laws that
control and power esserbus-PLus warning devices can be installed in this fire protection
housing in ​accordance with DIN4102 part 2 with approval according to DIBT. The housing
is a ​component of VdS device approval and, as an approved cabinet, supplies power to ​the
warning devices for over 30 minutes. Other housings do not fulfill the approval require­
ments and may not be used. In addition, the housing fulfills fire load insulation ​requirements in accordance with §40 paragraph 2 of the MBO, therefore Fire Alarm Control ​Panel
IQ8Control and FlexES Control can be used for necessary emergency and evacuation exits
as well. ​Should the interior of the housing ignite, the air intake openings will automatically
close ​and a fire spread will be prevented. Maximum one Fire Alarm Control Panel IQ8Control C/M or FlexES Control including transmission device may be built into the housing. As ​
operation level 1 cannot be reached in accordance with EN 54-2, an FAT (fire brigade indicating panel) can be necessary ​for initial information after consultation with the responsible fire department. It is to be ​assured that the fire protection housing door always
remains closed during normal opera­tion.
4
5
6
7
8
Technical Data
Type of protection
Color
IP41
light gray (other colors available for an additional ​
charge)
approx. 164 kg
Weight
9
Mounting material, sealing kit and cable sealing material incl. base 805590, without detector
Front view
Side view
10
Top view
11
12
1324
mm
340
mm
1200
mm
13
14
500 mm
624 mm
434 mm
15
Dimensions illustration
788031
Fire protection housing F30 LO
As 788030, but door hinge left.
231
Installation & Service
798655
Services
Log book for FAS
1
Multilingual file for fire alarm systems suitable for logging operating states, events and ​
maintenance work, etc.
232
www.hls-austria.com
1
2
3
4
5
6
7
8
9
10
Appendix
Planning Guide
234
Orders Forms
Part Number Index
235-240 11
241-243
Index
244-250
12
13
14
15
233
Appendix
Planning Guide
Planning Guide for Loop Installation
This is a planning guide for loop-powered alarm devices.
The alarm current of each alarm device is defined as a load factor. When added up, the total load factor defines the
loop length and the maximum number of alarm devices.
The maximum load factor of all alarm devices may not exceed 96. Altogether up to 127 bus devices per loop can still
be connected. The "load factor" download file for easier load factor calculation is available within our customer sec tion at http://www.esser-system.com.
Load factors:
Part No.
802382
802383
802384
802385
802386
807205
807206
807212
807213
807214
807224
807322
807332
807372
806282
Type of alarm signalling device
Load factor
O/So optical smoke detector IQ8Quad ................................................................2
O2T/F multisensor IQ8Quad with integr. flash .....................................................2
O2T/So multisensor IQ8Quad with integr. sounder ..............................................2
O2T/FSp multisensor IQ8Quad with integr. flash, sounder and speech ...............3
O2T/SpSo multisensor IQ8Quad with integr. sounder and speech .....................3
Sounder IQ8Alarm, housing: white ......................................................................3
Sounder IQ8Alarm, housing: red .........................................................................3
Optical alert device IQ8Alarm, housing: white, lens: amber ................................3
Optical alert device IQ8Alarm, housing: white, lens: white, blue, green ..............3
Optical alert device IQ8Alarm, housing: red, lens: red ........................................3
Combi sounder IQ8Alarm, housing: red, Lens: red .............................................3
Speech alarm unit IQ8Alarm, housing: white ......................................................3
Speech alarm unit IQ8Alarm, housing: red .........................................................3
Combi speech alarm unit IQ8Alarm, housing: red, lens: red ...............................3
Addressable base sounder esserbus-PLus ..........................................................2
Table 1.1: Maximum loop length depending on the total load factor
Maximum powered loop length
total load factor
up to 700 m ................................................................................................................. 91 up to 96
up to 800 m ................................................................................................................. 85 up to 90
up to 900 m ................................................................................................................. 79 up to 84
up to 1000 m ............................................................................................................... 73 up to 78
up to 1100 m ............................................................................................................... 67 up to 72
up to 1300 m ............................................................................................................... 61 up to 66
up to 1500 m ............................................................................................................... 55 up to 60
up to 1700 m............................................................................................................... 49 up to 54
up to 2000 m............................................................................................................... 43 up to 48
up to 2500 m............................................................................................................... 37 up to 42
up to 3000 m .............................................................................................................. 31 up to 36
up to 3500 m............................................................................................................... 1 up to 30
Example 1:
How many IQ8Alarm alarm signaling devices with load factor 3.0 can be connected to one analog loop?
96 (max. total load factor): 3.0 (load factor) = up to 32 IQ8Alarm devices can be connected
to each loop depending on the loop length (up to 700 m)
Example 2:
Various types of alarm signaling devices are connected to one loop:
Load factor
4 x 807205 alarm devices with load factor 3,0
= 4 x 3,0
27 x O2T/So multisensor IQ8Quad (802384) with load factor 2,0
= 27 x 2,0
total load factor
= 12
+
= 54
= 66
As shown in table 1.1, the maximum loop length for a total load factor of 66 is 1300 m (at a wire gauge 0.8 mm).
Example 3:
For alarm signaling with sounder, 25 x 802384 IQ8Quad O²T/So
detectors are installed - each in one office. What is the maximum loop length?
Load factor for one 802384 IQ8Quad O²T/So detector = 2 (load factor)
25 IQ8Quad O²T/So x 2 (load factor) = 50 (total load factor)
As shown in table 1.1, the maximum loop length is 1700 m (at a wire gauge 0.8 mm).
234
www.hls-austria.com
Orders Forms
Appendix
OA-No.
1
Order Form WINMAGplus / WINMAGLite
Telefax master
Honeywell Life Safety Austria GmbH
Lemböckgasse 49
1230 Vienna, Austria
2
Fax +43 1 600 60 30-900
3
4
1. License data
Please fill in the form for data collection
5
End user data (data must be entered: min. 8, max. 45 characters)
Name:
6
Street:
Town/City/Country:
Property:
7
Installer data: (data must be entered: min. 3, max. 45 characters)
8
Name:
Street:
Town/City/Country:
9
Contact person:
Entry of data optional: (max. 12 characters)
Phone:
10
Fax:
Email: (max. 45 characters)
(Please note that when completing this field, you agree that the licensing file will be sent via E-Mail.)
11
2. Ordering
One of the following must be selected.
2.1 WINMAG control center software basic package (select options on page 2)
1 x 013610 WINMAGplus basic package
1 x 013635 WINMAGLite
12
13
2.2 WINMAGplus retrofitting of options (select options on page 2)
1 x 013609 retrofitting of options from V6.0
14
2.3 WINMAG Upgrade
1 x 013616 Upgrade WINMAG from V 6.0 to WINMAGplus
1 x 013617 Upgrade WINMAG up to V 5.0 to WINMAGplus
for USB interface
15
for Parallel interface
license number
1 x 013636 WINMAGLite Upgrade to WINMAGplus basic package
license number
1 x 013645 WINMAG-Dongle-CrossDate from parallel to USB port
license number
235
Appendix
Orders Forms
Order from WINMAGplus - Part 2
Telefax master
3. Options a basic license is required for each connection)
Multi-station / distributed PCs
Part No.
Designation
013631
Basic license (USB Port 1))
013633
Basic license, including dongle for USB port
013590
Universal Gateway for Workstations (USB Port)
013601
License intrusion detection technology
013626
License fire detection technology
013603
License access control technology
013604
License CCTV technology
013605
License escape door control
013657
WINMAGplus license VA/PA
013656
WINMAGplus license nurse call systems
013606
License Connection Server
013607
Connection server developers kit
013608
License - WINMAGplus remote data transmission
013609
WINMAGplus control centre software -
Computer
Computer
(3 month runtime version)
post installation upgrade
013611
License OPC-Server
013612
License OPC-Client
013613
License Notification
013614
License OEM
013618
License 500 OPC/BacNet Datapoints
013619
License translation tool
013623
License interfacing DEZ 9000
013624
Option redundance
013625
License - WINMAGplus client
013634
One-time basic license for USB port (extension of 3 month)
for Part No. 013633.10
013640.10
WINMAGplus control centre software - remote-access kit
013650
License Escalation
013651
License DTMF
013652
License Customized rights
013653
License 4 x Multi Screen2)
013654
License - WINMAGplus control centre software
013655
License AutoCAD
013660
License WEBX
Update number3)
(for Winmag Version > Version 6)
One of the listed part-numbers has to be chosen
Number of PC’s, to which network data are given
3)
The update number is given by the info dialog window, or up from version 8, from the textfile lizenzinfo.txt
1)
2)
Date/Signature
236
www.hls-austria.com
Computer
Orders Forms
Appendix
Bestellinformation für Alarmgeber IQ8Quad und IQ8Alarm
1
Die Artikel 802385, O²T/FSp-Multisensormelder IQ8Quad und 807372, Kombi Sprachalarmgeber IQ8Alarm, können auch
in anderer Zusammensetzung von Landessprachen bestellt werden.
In diesen Sprachalarmgebern sind standardmäßig folgende fünf Sprachen programmiert. Die jeweiligen Sprachen sind
mit den fünf Standard-Sprachdurchsagen des IQ8Quad (Art.-Nr. 802385) und dem IQ8Alarm (Art.-Nr. 807372) belegt.
2
3
Länder-Code
gem. ISO 3166
-Alpha-2
SprachenCode gem.
ISO 639-1
Evakuierung 1
Evakuierung 2
Alarm
Dies ist ein
Feueralarm. Bitte
verlassen Sie das
Gebäude umgehend
über die nächsten
Fluchtwege. Die
Feuerwehr ist alarmiert.
Achtung, Achtung!
Dies ist eine Gefahrenmeldung. Bitte verlassen
Sie das Gebäude
über die nächsten
Ausgänge.
Achtung, im Gebäude
ist eine Gefahrensituation
gemeldet worden. Bitte
bleiben Sie ruhig,
und warten Sie auf
weitere Anweisungen.
Dies ist eine
Testdurchsage.
en
This is a fire alarm.
Please leave the
building immediately
by the nearest
available exit.
Attention please.
This is an emergency.
Please leave the
building by the
nearest available exit.
An incident has been
reported in the building.
Please await further
instructions.
This is a test
message.
No action is
required.
fr
Ceci est une
alarme incendie,
veuillez évacuer
immédiatement
les locaux par la
sortie la plus proche.
Votre attention
s'il vous plaît, ceci
est une alarme.
Veuillez évacuer
les locaux par la
sortie la plus proche.
Votre attention s'il vous
plaît,ceci est une
alarme. Veuillez
évacuer les locaux
par la sortie la plus
proche.
Esto es una alarma de
incendio. Abandonen
por favor el edificio
inmediatamente por
la salida de
evacuación
más cercana.
Atención. Esto es una
emergencia. Por favor
abandonen el edificio
por la salida de
evacuación
más cercana.
Atención, se ha
reportado un
incidente
en el edificio.
Aguarden por favor
otras instrucciones.
Esto es un
mensaje
de prueba.
No se requiere
ninguna acción.
La emergencia ha
sido cancelada.
Pedimos disculpas
por las molestias
causadas.
Attenzione.
Allarme incendio.
Abbandonare l'edificio
tramite l'uscita di
emergenza più vicina.
Attenzione.
Allarme in corso.
Vi preghiamo di recarvi
presso l'uscita di
emergenza più vicina.
Attenzione.
E' stato rilevato un
allarme.Ulteriori
disposizioni vi
verranno comunicate
appena possibile.
Attenzione.
E' in corso una
prova di allarme.
Non è richiesta
alcuna azione.
Attenzione. Cessato
allarme.La situazione
di normalità è stata
ripristinata.
de
Deutschland
(DE)
England
(GB)
Frankreich
(FR)
es
Spanien
(ES)
it
Italien
(IT)
Testnachricht
Ceci est un test.
Entwarnung
4
Die Gefahrensituation
ist jetzt behoben. Wir
entschuldigen
uns für jegliche
Unannehmlichkeiten.
5
The emergency is
now cancelled. We
apologise for any
inconvenience.
6
7
L'alarme est à
présent annulée.
Veuillez nous
excuser pour le
désagrément.
8
9
10
Standard Sprachdurchsagen der IQ8Quad Melder und IQ8Alarm
Nr.
Beschreibung
Frequenz
Pulsrate
Komplex
1
Schulglocke
Komplex
2
FP 1063.1 Telecoms
BS 5839 Pt1
Alternierend 800 / 970 Hz bei 2 Hz
3
BS 5839 Pt1
Alternierend 800 / 970 Hz bei 1 Hz
f
4
BS 5839 Pt1
Intermittierend 970 Hz bei 1Hz 0,5 Sek.
f
5
BS 5839 Pt1
Intermittierend 2850 Hz bei 1Hz 0,5 Sek.
f
6
BS 5839 Pt1
Intermittierend 970 Hz 1/4 Sek. an – 1 Sek. aus
f
7
BS 5839 Pt1
Permanent 970 Hz
f
8
BS 5839 Pt1
Sweep tone 800 Hz bis 970 Hz bei 7 Hz
f
f
0,25 Sek.
0,25 Sek.
9
BS 5839 Pt1
Sweep tone 800 Hz bis 970Hz bei 1Hz
f
10
DIN Ton
DIN 33404 Part 3
1.200 - 500 Hz bei 1 Hz
f
11
Franz. fire sound
554 Hz/100 ms + 440 Hz / 400 ms + 10 %
f
12
NL - Slow Whoop
500 Hz - 1.200 Hz bei 3,5 Sek., Unterbrechung von 0,5 Sek.
f
13
US - Horn
Permanent 485 Hz
f
14
US - Horn with
Temporal Pattern
Intermittierend 485 Hz (0,5 Sek. an; 0,5 Sek. aus; 3 Mal;
1,5 Sek. aus; Wiederholung)
f
15
US - March Time
Alternierend 485 Hz (0,25 Sek. an;
0,25 Sek. aus; Wiederholung)
16
US - Slow Whoop
Sweep tone 500 Hz bis 1.200 Hz
(4,0 Sek. an; 0,5 Sek. aus; Wiederholung)
17
US - Siren
18
US - Hi/Lo
19
US - NFPA Whoop
20
IMO GA-Signal
Sweep tone 600 Hz bis 1200 Hz
(1,0 Sek. an, Wiederholung)
Alternierend 100 Hz / 800 Hz (0,25 Sek. an;
Alternierend; 0,25 Sek. an, Alternierend, Wiederholung)
Sweep tone 422 Hz bis 775 Hz (aufwärts
sweep 0,85 Sek.; 3 Mal; 1 Sek. aus; Wiederholung)
Intermittierend 800 Hz (1,0 Sek. an; 1,0 Sek.
aus: 7 Mal; 2,0 Sek. an: 2,0 Sek. aus; Wiederholung)
11
t
12
0,5 Sek.
0,5 Sek.
0,5 Sek.
0,5 Sek.
0,5 Sek.
0,5 Sek.
0,25 Sek.
t
1,5 Sek.
t
1,5 Sek.
1,0 Sek.
t
13
t
t
10 ms
t
1,0 Sek.
t
14
1,0 Sek.
t
0,1 Sek.
0,4 Sek.
t
3,5 Sek. 0,5 Sek.
t
15
t
0,5 Sek.
1,5 Sek.
0,5 Sek.
f
f
f
f
f
f
t
0,25 Sek.
0,25 Sek.
t
4,0 Sek. 0,5 Sek.
t
1,0 Sek.
t
0,25 Sek.
0,25 Sek.
0,85 Sek.
1,0 Sek.
1,0 Sek.
t
1,0 Sek.
t
t
Tontabelle der IQ8Quad Melder und IQ8Alarm
237
Appendix
Orders Forms
Order Information: Individual Combination of Languages
Up to five languages can be provided per alarm signaling device.
Other combinations of languages can be ordered in accordance with the following order form.
The delivery time is four weeks. Please note that returns or cancellations are not possible.
Order numbers for individual combination of languages:
IQ8Quad O²T/FSp Multi-sensor Detector
IQ8Alarm "Combi" Speech Alarm
802385.SV98
807372.SV98
Description:
Individual combination of languages
802385.SV98 / 807372.SV98
For example:
Phrase 1 Phrase 6 Phrase 11 Phrase 16 Phrase 21 -
802385.SV98
NL_nl
GB_en
DE_de
TR_tr
RU_ru
_____
5
10
15
20
25
NL_nl
GB_en
DE_de
TR_tr
RU_ru
The message type per language is always the
same unless indicated otherwise in the chart:
"Additional languages for individual combination”:
1 Evacuation 1
2 Evacuation 2
3 Alarm
4 Test message
5 All clear signal
Order Information: Customized Combination
In case you should need individual texts differing from the standard speech messages, additional signal tones or other languages which are not listed in the order form, please contact the technical sales consultant in your area.
Order numbers for individual programming of speech announcements / signal tones:
IQ8Quad O²T/FSp Multi-sensor Detector
IQ8Alarm "Combi" Speech Alarm
802385.SV99
807372.SV99
Description:
Individual combination of customer-specific
special texts / special tones 802385.SV99 / 807372.SV99
802385.SV99
NL_nl
GB_en
DE_de
TR_tr
RU_ru
Extra
For example:
Phrase 1 Phrase 6 Phrase 11 Phrase 16 Phrase 21 Phrase 26 -
5
10
15
20
25
31
NL_nl
GB_en
DE_de
TR_tr
RU_ru
Extra
(customer specific special texts / special tones)
Information about delivery time and price of recording special texts and special tones available upon request. Please note
that the maximum recording time is 169 seconds. Also please note that returns or cancellations are not possible.
The programming of speech and/or tone data is carried out at the factory according to your specifications.
The programming of the customer data is carried out via the tools 8000 programming software.
Please take a look at the relevant instructions in the online help.
238
www.hls-austria.com
Orders Forms
Appendix
Additional Languages for Individual Combination
Country code
acc. to ISO
3166 -Alpha-2
BA
Language
code acc.
to ISO
639-1
Evacuation 2
Alarm
Test-message
All-Clear
bs
Ovo je požarni alarm Molimo
da odmah napustite zgradu
koristeći najbliži raspoloživi izlaz.
Pažnja. Ovo je obavještenje o
opasnosti. Molimo napustite
zgradu koristeći najbliži
raspoloživi izlaz.
U zgradi se dogodio incident.
Molimo sačekajte dalja uputstva.
Ovo je poruka za ispitivanje
sistema. Možete nastaviti sa
vašim akltivnostimo.
Opasnost je prestala.
Izvinjavamo se radi eventualnih
neugodnosti.
pt
Atenção.
Esta é uma emergência.
Por favor, abandonem o edifício
pela saída de emergência
mais próxima.
Isto é um alarme de incêndio.
Abandonem por favor, o edifício
imediatamente pela saída
de emergência mais próxima
Atenção foi reportado um
incidente no edifício.
Aguardem, por favor,
outras instruções.
Esta é uma mensagem de teste.
Não se requer nenhuma ação.
A emergência foi cancelada.
Pedimos desculpas pelos
problemas causados
da
Brandalarmen er aktiveret forlad
venligst bygningen, anvend
nærmeste nødudgang.
Dette er en nødsituation, forlad
bygningen brug de opmærkede
flugtveje.
Et varsel om brand bliver undersøgt,
afvent nærmer besked.
Dette er en test melding
ingen tiltag nødvendig.
Normal tilstand er genoprettet,
faren er overstået.
fi
Huomio, kiinteistössä on havaittu
automaattinen paloilmoitus. Poistu
rakennuksesta käyttäen ohjattuja
reittejä. Hissien käyttö on kielletty.
Huomio, turvallisuussyistä
Huomio, paloilmoitin on ilmoittanut
kiinteistöstä on poistuttava
mahdollisesta vaaratilanteesta.
välittömästi. Käytä ohjattuja reittejä. Tutkimme asiaa ja annamme pian
lisätietoja.
Paloilmoitinjärjestelmää
testataan.
Palohälytys on ohi. Tilanne on
palautunut normaaliksi.
el
Αυτό είναι ένα μήνυμα συναγερμού
για πυρκαγιά. Παρακαλώ
εγκαταλείψτε το κτίριο αμέσως
από τις εξόδους κινδύνου. Η
πυροσβεστική έχει ειδοποιηθεί.
Προσοχή, προσοχή! Αυτό είναι
ένα μήνυμα για κατάσταση
κινδύνου. Παρακαλώ εγκαταλείψτε
το κτίριο από τις επόμενες εξόδους.
Προσοχή στο κτίριο υπάρχει
κατάσταση κινδύνου. Παρακαλώ
παραμείνετε ψύχραιμοι και περιμένετε
επόμενες οδηγίες.
Αυτή είναι μια δοκιμαστική
ανακοίνωση.
Η κατάσταση κινδύνου έχει
αρθεί. Ζητούμε συγγνώμη
για τυχόν δυσάρεστες
καταστάσεις που προκλήθηκαν.
ca
Aixó es una alarma d´incendi.
Siusplau abandonin l´edifici
inmediatament per la sortida
d´evacuació més propera.
Atenció. Aixó es una emergencia.
Siusplau abandonin l´edifici per la
sortida d´evacuació més propera.
Atenció. S´ha notificat un
incident a l´edifici. Siusplau,
esperin altres instruccions.
Aixó es un missatge
de prova. No es
requereix cap acció.
L´alarma ha estat
cancel.lada. Preguem
disculpin les molesties.
hr
Ovo je pozarni alarm. Molimo
odmah napustite objekt koristeci
najblizi izlaz za nuzdu. Vatrogasna
postaja je alarmirana.
Pozor! Pozor! Ovo je priopcenje o
neposrednoj opasnosti. Molimo
odmah napustite objekt koristeci
najblizi izlaz za nuzdu.
Pozor! U objektu je prijavljena
opasnost. Molimo ostanite
mirni i pricekajte daljnje
upute.
Ovo je probno
priopcenje. Nikakve
mjere nisu neophodne.
Opasnost je prestala.
Ispricavamo se radi
eventualnih neugodnosti.
nl
Attentie,
er is een brandalarm.
Verlaat het gebouw via de
dichtstbijzijnde uitgang.
Attentie,
er is een calamiteit.
Verlaat het gebouw via de
dichtstbijzijnde uitgang.
Attentie,
er volgt een blussing,
verlaat de ruimte.
Dit is een testalarm,
dit is een testalarm.
Einde alarmmelding,
einde alarmmelding.
no
Brannalarmen er utløst, forlat
bygget, bruk de oppmerkede
rømningsveiene.
Dette -er en nødsituasjon, forlad
bygget, bruk de oppmerkede
rømningsveiene.
Et automatisk varsel om brann blir
undersøkt, avvent nærmere beskjed.
Dette er en testmelding,
ingen tiltak nødvendig.
Normaltilstand er
gjenopprettet, faren er over.
pl
Uwaga! Wystąpił alarm pożarowy.
Proszę natychmiast opuścić
budynek najbliższym dostępnym
wyjściem ewakuacyjnym.
Proszę o uwagę! To jest komunikat Uwaga. W budynku wystąpiło
alarmowy. Proszę opuścić budynek zdarzenie alarmowe. Proszę spokojnie
najbliższym dostępnym wyjściem
oczekiwać dalszych instrukcji.
ewakuacyjnym.
To jest komunikat testowy.
Nie są wymagane żadne
działania.
Stan alarmu został odwołany.
Przepraszamy za wszelkie
niedogodności i utrudnienia.
pt
Isto é um alarme de incêndio.
Por favor abandonem o edifício
imediatamente pela saída de
evacuação mais próxima.
Atenção. Isto é uma emergência.
Por favor abandonem o edifício
pela saída de emergência mais
próxima.
Atenção, isto é apenas um
ensaio
O alarme foi cancelado. Queiram
desculpar o inconveniente.
ro
Atenţiune, atenţiune! S-a declanşat
o alarmă de incendiu. Vă rugăm
părăsiţi imediat clădirea pe cea mai
apropiată cale de evacuare.
Alarma a fost transmisă la pompieri.
Atenţiune! Acesta este un mesaj de Atenţiune. În clădire a fost semnalat
urgenţă. Vă rugăm părăsiţi clădirea un incident. Vă rugăm să vă păstraţi
pe cea mai apropiată cale de ieşire. calmul şi să aşteptaţi noi instrucţiuni.
Situaţia de urgenţă a luat
sfârşit. Ne cerem scuze
pentru eventualele
inconveniente.
Acesta este un mesaj de test.
12
sr
Ovo je požarni alarm! Molimo
vas da odmah napustite zgradu
koristeći najbliži raspoloživi izlaz.
Pažnja! Ovo je obaveštenje o
opasnosti. Molimo vas da
naupustite zgradu koristeći
najbliži raspoloživi izlaz.
U zgradi se desio incident.
Molimo vas da sečekate dalja
uputsva.
Ovo je poruka za ispitivanje
sistema.
Možete nastaviti sa vašim
aktivnostima.
Opasnost je prestala.
Izvinjavamo se zbog
eventualnih neugodnosti.
13
ru
Внимание. Пожарная тревога.
Пожалуйста покиньте помещение
через ближайшие аварийные
выходы.
Внимание. Это предупреждение о
пожарной опасности. Пожалуйста
покиньте помещение через
ближайшие выходы.
Внимание. Поступило
предупреждение о пожарной
опасности. Пожалуйста сохраняйте
спокойствие и ждите дальнейшей
информации.
Отмена пожарной тревоги.
Ситуация нормализовалась.
Извините за причинённые
неудобства.
Тестовое сообщение. Идет
проверка системы
пожарной сигнализации.
Brandlarmet är utlöst, lämna
omedelbart byggnaden genom
närmaste utgång.
Detta är en nödsituation, lämna
omedelbart byggnaden genom
närmaste utgång.
Larm om brand i byggnaden blir
undersökt, invänta närmare besked.
Detta är ett testmeddelande,
ingen åtgärd är nödvändig.
Normalt tillstånd är återupprättat,
faran är över.
sk
Toto je požiarny poplach. Opusťte
prosim okamžite budovu najbližším
núdzovým východom!
Pozor, hrozí nebezpečenstvo.
Opusťte prosim budovu
najbližším núdzovým
východom!
V budove bola vyhlásená
pohotovosť. Počkajte prosim
na ďalšie pokyny.
Toto je testovacie
hlásenie. Nie je
potrebne naň
reagovať.
Pohotovosť bola
odvolaná.Ospravedlňujeme
sa za pripadne ťažkosti.
cs
Toto je požární poplach.
Prosím, opusťte okamžitě
budovu nejbližším únikovým
východem.
Pozor, hrozí nebezpečí.
Prosím, opusťte budovu
nejbližším únikovým
východem.
V budově byla vyhlášena
pohotovost. Prosím, vyčkejte
dalších instrukcí.
Toto je testovací
hlášení. Není třeba na
něj reagovat.
Pohotovost je nyní
odvolána. Omlouváme se
za případné obtíže.
tr
Dikkat ! Dikkat ! Acil
Yangın Uyarısı. Lütfen
dirhal binayı boşaltın.
Acil bir durum var. Lütfen
binayı en yakın çıkış
noktasından terkedin.
Bu bir yangın uyarısıdır. Bu
bir yangın uyarısıdır.
Talimatlar için beklemede
kalın. Talimatlar için beklemede
kalın.
Yangın uyarısı test
edilmektedir. Bir şey
yapmanız gerekmiyor.
Bir şey yapmanız
gerekmiyor.
Tehlike geçmiştir. Tehlike
geçmiştir. Bir şey yapmanız
gerekmiyor.
hu
Tűzriadó! Kérem, azonnal
hagyják el az épületet az
Önökhöz legközelebb eső
kijáraton!
Figyelem! Vészhelyzet!
Kérem, azonnal hagyják el
az épületet az Önökhöz
legközelebb eső kijáraton!
Az épületben váratlan esemény
történt. További utasításig
kérem várjanak!
Ez egy tesztüzenet.
Vészhelyzet törölve. Az
esetleges
kellemetlenségekért
elnézésüket kérjük.
Bosnia
BR
Brasil
CN
1
Evacuation 1
2
3
zh
China
Mandarin
DK
4
Denmark
FI
Finland
GR
Greece
ES
Catalonia
HR
Croatia
NL
Netherlands
NO
5
6
7
8
9
Norway
PL
10
Poland
PT
Portugal
RO
Romania
RS
Serbia
RU
Russia
SE
sv
Atenção, ocorreu um incidente no
edifício. Por favor aguardem mais
instruções.
11
14
15
Sweden
SK
Slovakia
CZ
Czech
Republic
TR
Turkey
HU
Hungary
239
Appendix
Orders Forms
Order Form for Individual Combination of Languages
Honeywell Life Safety Austria GmbH
Lemböckgasse 49
1230 Vienna, Austria
1. Customer Data
Fax +43 1 600 60 30-900
Telefax master
Please fill out the following form for the registration of these data.
Company:
Customer ID:
Street:
Zip Code/City:
Contact Person:
E-mail:
Telephone:
Fax:
Property:
Order Number / Order Text:
Novar Order Number:
2. Type / Amount
802385.SV98
Amount
807372.SV98
Amount
3. Languages
Languages
max. 5 languages
Bosnian
Brazilian
Chinese Mandarin
Danish
German
English
Finnish
French
Greek
Dutch
Italian
Catalan
Croatian
Norwegian
Polish
Portuguese
Romanian
Russian
Swedish
Slovak
Spanish
Czech
Turkish
Hungarian
Country Code according
to Speech ISO 3166
BA
BR
CN
DK
DE
GB
FI
FR
GR
NL
IT
ES
HR
NO
PL
PT
RO
RU
SE
SK
ES
CZ
TR
HU
Repeat Orders or Additions
For repeat orders or additions please give the Order No. or
the serial number of the detector with special languages.
Code according to
ISO 639-1
bs
pt
zh
da
de
en
fi
fr
el
nl
it
ca
hr
no
pl
pt
ro
ru
sv
sk
es
cs
tr
hu
Order number:
Serial number:
To be filled out by Novar GmbH:
Please forward to Production when filled out!
Order number:
Position:
Date/Signature
240
www.hls-austria.com
Part Number Index
Part No.
Page
013405.1052
01359063
01360160
01360361
01360461
01360561
01360662
01360762
01360862
01360960
01361059
01361163
01361263
01361364
01361465
01361660
01361760
01361863
01361962
01362062
01362361
01362464
01362565
01362661
01363059
01363159
01363359
01363460
01363568
01363668
013640.1065
01364361
01364560
01365064
01365164
01365264
01365365
01365565
01365662
01366064
01800137
01800237
01800437
01800637
01800737
01800937
01801037
01801137
01805138
045040201
Part No.
Page
050510228
057633227
06042699
06042798
060429103
060430.10102
060431103
070450228
382040228
701040113
704070114
704147227
704148227
704477.10110
704800112
704801.10111
704804111
704850112
704854111
704870112
704874111
704890112
704900107
704901107
704902107
704903107
704904107
704910113
704911114
704912114
704915113
704917114
704965132
704967140
704981131
704985132
706030117
706030.EX118
73623522
73626422
74321223
74324523
74324823
74402724
74402824
74402924
74403024
761243151
761244151
761245151
Part No.
Page
761246151
761247151
761290150
761300165
761301165
761302165
761303165
761304165
761305165
76130672
761310165
761312162
761313162
761314162
761315159
761316159
761317160
761317.50160
761317.50.H162
761317.H162
761318161
761322163
761323163
761347145
761349146
761440163
761441163
761501169
761506169
761509170
761512170
761515167
761516168
761517169
761519166
761519.500166
761535181
761536181
761542.10180
761543.10180
761546.10182
761547182
761549180
761694117
761697119
762401169
762406167
762407168
762504169
762505169
Part No.
1
Page
764730222
764731222
764732222
764733223
764734223
764735223
764736224
764737224
76474488
76474588
76475289
76475489
76479040
764852225
764855225
765612218
765624218
766225198
766226198
766230199
766237199
766238199
766239199
766240205
766240.10206
766240.20205
766240.30206
766253201
766262200
766303202
766304202
766305202
766306202
766307202
766308202
766410203
766411203
766412203
766413204
766414204
767123217
767145215
767153215
767510226
767800
94, 197
767813.10219
767814.10219
769070104
769080104
76980391
2
3
4
5
6
7
8
9
10
11
12
13
14
15
241
Part Number Index
Part No.
Page
769813104
769814104
76982827
769870.20103
769871.20104
769910115
769911115
76991423
76991523
769916115
769921113
77167020
77238652
77238752
77244522
77247619
77247719
77247819
77247919
781332185
781333185
78133536
78133636
78133736
781443147
781444148
781445149
781446148
781447148
781448149
781449149
78148296
78155097
781682115
781692115
781693116
781694116
781698116
781699116
781804207
781814207
782302143
782303143
782304143
782306144
782307144
782308144
782310143
782311142
782315142
242
www.hls-austria.com
Part No.
Page
783312144
783313144
784382.D020
78438520
78471042
784710.PL42
784725.PL43
78473444
78474342
784743.PL42
78474444
78475344
78475445
78476349
78476450
78476650
784840.1048
784841.1048
78484220
78484349
78485550
78485651
78485951
78486549
78489222
78510141
78510741
78510941
78511341
78511541
78575338
78600018
78600216
78610018
78610216
78630217
78640217
78650217
78680217
78690217
78753020
78753120
78753221
788012.4028
788013.4028
788014.4029
788014.40.CZ30
788014.40.GB30
788014.40.PL30
788014.40.RO30
Part No.
Page
788014.40.RU30
788014.40.SK30
788015.4030
78801631
788023.1031
788030231
788031231
78809318
78840031
78840131
78840231
78840431
78840631
788600229
788601229
788602226
788603.10226
788605227
78860652
788612130
788650.10229
788651.10229
788652226
78865330
78865430
788655
130, 230
788656
130, 230
78930011
78930111
78930212
78930315
78985591
78985691
789860.1025
78986125
789862.1026
78986326
78986427
78986627
796349219
798655232
801515.10171
801521.10172
801522.10172
801523.10174
801524.10174
801525.10174
801531.10173
801532.10173
801533.10175
Part No.
Page
801534.10175
801535.10175
801540177
801541177
801542177
801543.10176
801544.10176
801547177
801548178
801549178
801550182
801600176
801602181
801604176
801605177
801606181
801824208
801825208
80217174
80217774
80227175
80237175
80237375
80237476
80237576
802379148
80238282
80238382
80238482
80238583
802385.SV9884
802385.SV9984
80238683
802386.SV9883
802386.SV9984
80247377
803271.EX86
803371.EX86
803374.EX86
804382.D020
804473.10110
80474487
80479140
804867132
804868131
80488022
804900108
804901108
804902108
804905109
Part Number Index
Part No.
Page
804906109
804980126
804981126
805550101
805551100
805552101
805553102
80556097
80557094
80557192
80557295
80557395
80557493
80557693
80557794
80558098
80558198
805582102
805583102
80558699
80558792
80558892
80558992
80559090
80559190
805593.10135
805594.10136
805595.10137
80559738
805601.10138
805602.10139
805603139
805604139
805605140
806201197
806202197
807205190
807206190
807212195
807213195
807214196
807224193
807322191
807322.SV98191
807322.SV99191
807332192
807332.SV98192
807332.SV99192
807372193
807372.SV98194
Part No.
Page
807372.SV99194
80800310
80800415
80813910
80821915
808600.24125
808600.230125
808610.10126
808611.10127
808613.30127
808615128
808619.10128
808623123
808623.10124
808624130
808626130
808630.10129
808631.10129
85005497
85005597
850056135
850057136
850058208
850059207
850060197
950101179
950104179
950107179
950110179
950113180
950116180
950119179
950123182
950298183
950299183
950301183
950303183
950304183
950305183
950306183
950307183
950308183
950310184
950311183
950312184
950313184
950314184
950315184
950316184
950447180
Part No.
Page
950950183
960000.10.GB34
960001.10.GB34
960002.10.GB34
960003.10.GB35
960004.10.GB35
960005.10.GB35
960006.10.GB35
960007.10.GB35
960100214
960101214
960102214
960103214
960109217
960110217
960120213
960121213
960122213
960123213
960124213
960127216
960128216
960129216
961698120
961699120
970120153
970121153
970122153
970123153
970124153
970129154
970130154
970131154
970135154
970136154
970137154
970140155
970141155
970142155
970143156
970144156
970145156
970146156
970147156
970150156
970151157
970152157
970153157
970154157
970155157
Part No.
1
Page
970160157
970161157
970165158
970170158
970220153
970221153
970222153
970223153
970224153
970300224
970301151
970302152
970303152
2
3
4
5
6
7
8
9
10
11
12
13
14
15
243
Index
Keyword
Page
A
Accumulator / battery kit
Adapter for Esser pole (part no. 769813)
Adapter module ADP-N3E
Adapter module ADP-N3S
Adapter module ADP-PRS-232
Adapter module ADP-PRS-422
Additional relay 12V DC
Addressable manual call point, IP66
Adhesive, 0.5 kg can with brush-in-cap
Air filter for aspirating smoke detectors
Air filter for LRS aspirating systems
Analog loop module
Analog loop module powered loop
Aspiration reducing film sheet, 2.0 mm
Aspiration reducing film sheet, 2.5 mm
Aspiration reducing film sheet, 3.0 mm
Aspiration reducing film sheet, 3.2 mm
Aspiration reducing film sheet, 3.4 mm
Aspiration reducing film sheet, 3.6 mm
Aspiration reducing film sheet, 3.8 mm
Aspiration reducing film sheet, 4.0 mm
Aspiration reducing film sheet, 4.2 mm
Aspiration reducing film sheet, 4.4 mm
Aspiration reducing film sheet, 4.6 mm
Aspiration reducing film sheet, 5.0 mm
Aspiration reducing film sheet, 5.2 mm
Aspiration reducing film sheet, 5.6 mm
Aspiration reducing film sheet, 6.0 mm
Aspiration reducing film sheet, 6.8 mm
Aspiration reducing film sheet, 7.0 mm
38
98
44
44
45
44
228
117
181
176
170
20
20
183
183
183
183
183
183
183
183
183
183
183
184
184
184
184
184
184
B
Back-flow valve for Titanus EB
Banderole for suction-reducing foil
Base cover for IQ8Quad
Base IP65 for IQ8Alarm, red
Base IP65 for IQ8Alarm, white
Base module for OVP modules
Base with side cable entry, red
Base with side cable entry, white
Basic license extension for USB port
Basic license for USB port 3-month duration
Basic license for WINMAGplus parallel port
Basic license for WINMAGplus USB port
Basic unit Titanus Pro Sens 2 EB
Basic unit Titanus Pro Sens EB
Basic unit Titanus Top Sens 2 EB
244
www.hls-austria.com
177
182
92
197
197
224
199
199
60
59
59
59
172
172
173
Keyword
Page
Basic unit Titanus Top Sens EB
173
3.6V Lithium battery
38
Battery 12 V DC / 1.2 Ah capacity
37
Battery 12 V DC / 2.1 Ah capacity
37
Battery 12 V DC / 7 Ah capacity
37
Battery 12 V DC / 12 Ah capacity
37
Battery 12 V DC / 17 Ah capacity
37
Battery 12 V DC / 26 Ah capacity
37
Battery 12 V DC / 38 Ah capacity
37
Battery 12V DC / 65Ah capacity
37
Battery extension housing
11
BME2Z00227
C
Cable drum for FO sensor cable 970150 or 970153
158
Cable gland M12 with nut
227
Cable gland M16
89
Cable gland M16 with nut
227
Cable turnbuckle for floating roof tank
152
Carrying bag for test equipment including cover for telescopic rods
99
Ceiling lead-through adapter ABS
180
Ceiling pendant mount for Fireray
162
CO capsule for multi-stimulus detector tester 805551 102
Combined optical-acoustic alarm device, 12 V DC, red 205
Combined optical-acoustic alarm device, 24 V DC, red 205, 206
Combined optical-acoustic alarm device, 24 V DC, red,
Asserta type
206
Compact unit Titanus Pro Sens EB
171
Condensate trap for aspirating smoke detectors
181
Connection server developers kit
62
Connection sleeve set for sensor cable
151
Control center software CD WINMAGplus basic kit
59
Control panel interface RS 232
27
Control relay for top-hat rail mounting
226
Conventional MCP electronic module
108
Conventional MCP electronic module with second microswitch108
Conventional MCP electronic module w/o snap-on function
108
Conversion kit for smoke detector tester 769870
104
Converter RS 232 / RS 485
225
Converter RS 232 / TTY
225
Corrugated polyester hose
180
CO test gas for smoke detector tester 805582
102
Cover plate for 766261 signal base
200
Cutting tool for FO steel sensor cable 970153
158
Index
Keyword
Page
D
Data points package
63
DC / DC converter 12 V / 24 V DC
36
DC / DC converter output voltage
36
DC / DC converter output voltage 24 V DC
36
Detector base with relay contact for IQ8Quad
90
Detector cover for detectors series 9x00 and/or base
91
Detector cover for detectors series 9x00 with base adapter
91
Detector cover for IQ8Quad with built-in alarm sounder 92
Detector cover for IQ8Quad w/o built-in alarm sounder 92
Detector dismounting tool for series 9000/9100/9200 91
Detector holder for aspirating smoke detection systems
Titanus EB
177
Detector module 0.5%/ m DM-TT-50L
175
Detector module 0.5 %/ m Type DM-TP-50
174
Detector module 0.10%/ m DM-TP-10L
174
Detector module 0.10%/ m DM-TT-10L
175
Detector module 0.015%/ m DM-TP-01L
174
Detector module 0.015%/ m DM-TT-01L
175
Detector removal tool
98
DIAG3 diagnostics tool for Titanus EB
178
Door closer, hold-open size 2-5
217
Door magnet with distance pipe incl. flexible anchor, 400 N,
175 mm
213
Door magnet with distance pipe incl. flexible anchor, 400 N,
325 mm
213
Door magnet with distance pipe incl. flexible anchor, 400 N,
475 mm
213
Door magnet with release button incl. flexible anchor, 400
N213
Door magnet w/o release button, 490 N
214
Door magnet w/o release button incl. flexible anchor, 400 N
213
DTS extension set
154
DTS interface box
154
Dummy cover 19", 2 HU
24
Dummy cover 19", 3 HU
24
Dummy cover 19", 5 HU
24
Dummy cover 19", 9 HU
24
E
E2000 APC 8° pigtail
157
E2000 APC adapter to connect two connectors 970160 157
EMC shield for IQ8Quad detector base
97
Emitter, high power, wired at 24 V DC
165
Emitter, standard power, battery version
165
Emitter, standard power, wired at 24 V DC
165
Keyword
1
Page
EOL-I terminating device
130
EOL-O terminating device
130
esserbus alarm transponder 4 IN 2 OUT
123
esserbus communication transponder
128
esserbus FSA transponder for fire doors
128
esserbus transponder 4 IN 2 OUT for UniVario
124
esserbus transponder 12 relays 8bit
126
esserbus transponder 32 LED
127
esserbus transponder FCT set 12 - 24 V
125
esserbus transponder FCT set 230 V
125
esserbus transponder SIE
127
essernet module, 62.5kBd
48
essernet module, 500kBd
48
essernet repeater, 62.5kBd
49
essernet repeater, 500kBd
49
Evaluation unit DTS, 1 km
153
Evaluation unit DTS, 2 km
153
Evaluation unit DTS, 3 km
153
Evaluation unit DTS, 4 km
153
Evaluation unit DTS, 8 km
153
Evaluation unit DTS 19", 1 km
153
Evaluation unit DTS 19", 2 km
153
Evaluation unit DTS 19", 3 km
153
Evaluation unit DTS 19", 4 km
153
Evaluation unit DTS 19", 8 km
153
Ex-barrier for intrinsic safe detectors series IQ8Quad Ex (i)
87
Ex-barrier for intrinsic safe detectors series IQ8Quad Ex (i)
and 9100
88
Ex door magnet, 588 N
215
Ex door magnet, 1568 N
215
Ex horn, 12 V DC
201
Ex-i terminal box for 970300
151
Ex manual call point (conventional) IP66, yellow housing
120
Ex manual call point IP67, small housing, red
118
Explosion-proof conventional manual call point, IP66 119
Ex sounder DS10
201
Ex stop-button (conventional) IP66, blue housing
120
Extension housing
15
Extension housing for batteries and SZI 192 detector zones
11
Extension housing for SZI 192 detector zones
12
Extension module with 3 additional micromodule slots 19
Extension module with one additional micromodule slot 19
Extension pole
104
External power supply 2 A / 24 V DC 17Ah EN 54-4
34
External power supply 3 A / 24 V DC 17Ah EN54-4
34
External power supply 3 A / 24 V DC 28Ah EN 54-4
34
2
3
4
5
6
7
8
9
10
11
12
13
14
15
245
Index
Keyword
Page
External power supply 5 A / 24 V DC 17Ah EN 54-4
35
External power supply 5 A / 24 V DC 28Ah EN 54-4
35
External power supply 5 A / 24 V DC 40Ah EN 54-4
35
External power supply 7 A / 24 V DC 28Ah EN 54-4
35
External power supply 7 A / 24 V DC 40Ah EN 54-4
35
Extinguishing control panel 8010 Series 4 with operating
unit, Czech
30
Extinguishing control panel 8010 Series 4 with operating
unit, English
30
Extinguishing control panel 8010 Series 4 with operating
unit, German
29
Extinguishing control panel 8010 Series 4 with operating
unit, Polish
30
Extinguishing control panel 8010 Series 4 with operating
unit, Romanian
30
Extinguishing control panel 8010 Series 4 with operating
30
unit, Russian
Extinguishing control panel 8010 Series 4 with operating
unit, Slovakian
30
Extinguishing control panel 8010 Series 4 w/o operating
unit30
Extinguishing panel 8010 series 4 with operating unit,
German28
Extinguishing panel 8010 series 4 w/o operating unit
28
F
FB inform./operating system, DIN A4 horizontal layout,
Polish43
Fiber optic converter for essernet, multimode, F-SMA male
50
Fiber optic converter for essernet, multimode, F-ST male49
Fiber optic converter for essernet, single-mode
50
Field bus interface PLus
26
Filler panel front, neutral for IQ8Control C/M
18
Filter cartridge for air duct module 781443
148
Fire alarm control panel IQ8Control C
10
Fire alarm control panel IQ8Control C for 19" cabinet
10
Fire alarm control panel IQ8Control M
15
Fire alarm control panel IQ8Control M for 19" cabinet 15
Fire brigade operating panel, German
42
Fire brigade operating panel, Polish
42
Fire department indicating panel FAT3000
42
Fire protection housing F30 LO
231
Fire protection housing F30 RO
231
Fireray 50 RV with one prism
159
Fireray 100 RV with four prisms
159
Fireray 5000 detector head
162
Fireray 5000, line smoke detector, incl. controller, 50 m160
246
www.hls-austria.com
Keyword
Page
Fireray 5000, line smoke detector, incl. controller, 100 m
160
Fireray Eexd, line smoke detector for EX areas
161
Fixed anchor plate for door magnets 960100-960103 217
Fixed heat detector class B IQ8Quad
74
Fixed heat detector IQ8Quad
74
Flashing light, 12 V DC, amber
202
Flashing light, 12 V DC, green
202
Flashing light, 12 V DC, red
202
Flashing light, 24 V DC, amber
202
Flashing light, 24 V DC, green
202
Flashing light, 24 V DC, red
202
Flexible anchor plate for door magnets 960100-960103217
Floor-mounted brackt for door magnet 960120
216
Floor-mounted door magnet with release button, 490 N214
Flush-mount housing, gray
229
Flush-mount housing, white
229
Flush mount kit for base IQ8Quad
92
Flush mount release pushbutton for automatic door release
system, German
219
Foil for front face with universal text for large MCP ABS
70490x114
Foil for front face with universal text for large MCP ABS,
black lettering
114
FO sensor cable DTS safety FRNC
156
FO sensor cable steel FRNC
157
Front foil Titanus Pro Sens 2 EB
177
Front foil Titanus Top Sens 2 EB
178
8-fuse card
228
H
Hardware option TCP/IP converter, Ethernet RS232/RS485
52
Heat detector UniVario
143
Heat detector UniVario, 200 mm
143
Heat detector UniVario, 400 mm
143
Heat detector UniVario, 600 mm
143
Heat detector UniVario Flex, 2 m
144
Heat detector UniVario Flex, 6 m
144
Heat detector UniVario Flex, 9 m
144
High IP housing
130, 230
High IP housing base
130, 230
Housing for Ex-barrier
89
Housing kit
52
Housing with glass pane, blue, similar to RAL 5015
107
Housing with glass pane, green, similar to RAL 6002 107
Housing with glass pane, orange, similar to RAL 2011 107
Housing with glass pane, red, similar to RAL 3020
107
Housing with glass pane, yellow, similar to RAL 1021 107
Index
Keyword
Page
Housing with glass, red, in compliance with EN 54-11 111
I
Imager, 7° coverage, 24 V DC
165
Imager, 38° coverage, 24 V DC
165
Imager, 80° coverage, 24 V DC
165
Indicating and operating module LRS 110 - ESSER, English
169
Indicating and operating module LRS 110 - ESSER,
German169
Indicating and operating panel for ECP 8010, Czech
31
Indicating and operating panel for ECP 8010, English 31
Indicating and operating panel for ECP 8010, German 31
Indicating and operating panel for ECP 8010, Polish
31
Indicating and operating panel for ECP 8010, Romanian 31
Installation frame for transmission units and transponders
227
Interface module RS232/V24
52
Interface module TTY/CL 20mA
52
Internal extention with Modbus IP connectivity
154
I/O connection set
154
IP43 moisture-proof surface-mounted base adapter for
IQ8Quad detector base
95
IP43 protection for detector base IQ8Quad, flat design 94
IP43 protection for IQ8Quad detector bases, deep design95
IP54 kit for large manual call points 7048xx
114
IP55 kit for protective cover
116
IQ8Alarm combined alarm signaling device
193
IQ8Alarm combined speech alarm
193
IQ8Alarm combined speech alarm - customized version194
IQ8Alarm combined speech alarm - special language 194
IQ8Alarm optical alarm signaling device, amber
195
IQ8Alarm optical alarm signaling device, red
196
IQ8Alarm optical alarm signaling device, transparent, blue,
green195
IQ8Alarm sounder, red
190
IQ8Alarm sounder, white
190
IQ8Alarm speech alarm, red
192
IQ8Alarm speech alarm, red - customized version
192
IQ8Alarm speech alarm, red - special language
192
IQ8Alarm speech alarm, white
191
IQ8Alarm speech alarm, white - customized version 191
IQ8Alarm speech alarm, white - special language
191
IQ8FCT electronic module
126
IQ8FCT fire control transponder 1 IN 1 OUT
132
IQ8MCP electronic module
109
IQ8MCP electronic module w/o isolator but with relay 109
IQ8Quad OTblue-LKM
148
IQ8TAL electronic module
126
Keyword
1
Page
IQ8TAL technical alarm module 1 IN 1 OUT
131
IQ8Wireless cover for wireless interface, red and white 140
IQ8Wireless detector base
135
IQ8Wireless gateway for devices
136
IQ8Wireless mounting frame for IQ8Quad detectors, white
139
IQ8Wireless mounting frames for IQ8Alarm, red and white
139
IQ8Wireless transponder for devices, wall mount
137
IQ8Wireless universal interface w/o cover, red
138
IQ8Wireless universal interface w/o cover, white
139
3fold-IR-flame detector UniVario
142
IR flame detector X 9800
145
Isolation and assembly block for safety barrier
88
2
3
4
5
6
K
7
Kit DCF77 radio time module for IQ8Control & FlexES
Control22
Kit for suspended installation
96
8
L
Label for release pushbutton
Label plate for detector base IQ8Quad
Labels-sampling points wrap round VESDA systems
Laser FOCUS VLF-250 - ESSER, multilingual
Laser FOCUS VLF-500 - ESSER, multilingual
LCD indicator panel, Czech
LCD indicator panel, English
LCD indicator panel, Hungarian
LCD indicator panel, Polish
LCD indicator panel, Turkish
Lever lock - type 17 for key no. 801
Lever lock - type for key no. 901
Line heat detector LWM-1
Log book for FAS
Loop isolator for transponders
Loop LED remote indicator panel for 32 messages
LRS 300 PC-interface
LRS compact - ESSER, English
LRS compact - ESSER, German
LRS compact net - ESSER, English
LRS compact net - ESSER, German
9
219
93
182
166
166
41
41
41
41
41
23
23
150
232
130
40
169
167
167
168
168
10
11
12
13
14
15
M
Mains interference suppression filter type 2VK3
228
Manual call point IP67, small housing, red
117
Master box interface module
20
MCP electronic module Series 9000 with second microswitch110
247
Index
Keyword
Page
MCP electronic module Series 9200 with zone isolator 110
MCP housing aluminum, blue, neutral
112
MCP housing aluminum, gray, neutral
112
MCP housing aluminum, red, neutral
112
MCP housing aluminum, yellow, neutral
112
MCP housing with glass, blue, printed: house alarm-ESSER
111
MCP housing with glass, red, printed: house alarm-ESSER
111
MCP housing with glass, yellow, printed: house alarmESSER111
Metal key for large MCP
115
Micro splice-box for DTS FO cable
156
Mounting adapter for intermediate ceilings
94
Mounting bracket for lintel installation
94, 197
Mounting bracket for UniVario detector
144
22
Mounting frame 19" IQ8Control C/M
Mounting frame for small MCP, red and white
140
Mounting kit
227
Mounting set for round and insulated air ducts
149
MPG DP500
55
MPG DP7500
55
MPG DP35000
56
Multiple-sector interface in housing
31
Multi-stimulus detector tester
100
Multi-stimulus detector tester TF1001
101
O
O2T/F multisensor IQ8Quad
82
O2T/FSp multisensor detector IQ8Quad, customized
version84
O2T/FSp multisensor detector IQ8Quad with composition
of other languages
84
O2T/FSp multisensor IQ8Quad
83
O2T intelligent detector IQ8Quad Ex (i)
86
O2T multisensor IQ8Quad
76
O2T/So multisensor IQ8Quad
82
O2T/Sp multisensor IQ8Quad
83
O2T/Sp multisensor IQ8Quad, customized version
84
O2T/Sp multisensor IQ8Quad, special language
83
Operating front, English
16
Operating front for printer and w. take-up reel, English 17
Operating front with single zone indication 64, English 16
Operating front w. printer, w/o take-up reel, English
17
Operating module front 1/4 VGA and SZI for 64 zones,
English17
Operating module front with 1/4 VGA display and printer,
English17
Operating module front with 1/4 VGA display, English 17
248
www.hls-austria.com
Keyword
Page
Operating panel foil for large manual call point 80490x,
neutral113
Optical alarm signaling device, amber
203
Optical alarm signaling device, blue
204
Optical alarm signaling device, green
203
Optical alarm signaling device, red
203
Optical alarm signaling device, transparent
204
Optical smoke detector incl. base with relay output for base
transceiver stations (BTS)
72
Optical smoke detector IQ8Quad
75
Optical smoke detector IQ8Quad Ex (i)
86
Option - ability for customized interface rights (client-side)
64
Optional 2nd channel for evaluation unit DTS
154
Option - client
65
Option - DTMF control option
64
Option - escalation
64
Option IP55 shrink sleeve for large MCP 80490x
114
Option - notification
64
Option - redundance
64
Option - WEBX
64
OSID installation kit
165
O/So optical smoke detector IQ8Quad
82
OTblue multisensor detector IQ8Quad
76
OTG multisensor (CO) IQ8Quad
77
OT multisensor detector IQ8Quad
75
"Out of order" sign for large MCP, multilingual
113
OVP module for analog telephone lines
223
OVP module for control outputs
224
OVP module for esserbus / esserbus-PLUS loop
223
OVP module for essernet and RS-485 interfaces
222
OVP module for ISDN telephone lines
223
OVP module for TTY interfaces and standard detector
zones222
OVP module including base for 230 V power supply line
222
P
Panel 8010-option with control group indicator and alarm
counter, German
31
Peripheral module
19
Peripheral module with one additional micromodule slot 19
Pipe cutter for PVC / ABS pipes
182
Plastic key for large MCP
115
Plastic telescopic extension
99
Plastic telescopic rod
98
Plate for 1 prism
163
Plate for 4 prism
163
Index
Keyword
Page
Power supply unit for automatic door release systems, 12
V, 3 A
218
Power supply unit for automatic door release systems, 24
V, 1.5 A
218
Printer kit with paper take-up reel for IQ8Control C/M 22
Printer paper for printer 736233/736234/784892
22
Printer paper for printer 736259
22
1 prism for Fireray
163
3 prisms for Fireray
163
Programming unit LRS 200
169
Programming unit LRS 210
169
Protective cage
97
Protective cover for manual call points, English
116
Protective cover for manual call points, German
116
Protective kit for MCP and TAL, transparent
132
PVC 45° angle for 25 mm pipe
179
PVC 90° angle for 25 mm pipe
179
PVC 90° bend for 25 mm pipe
179
PVC detergent, 1l
181
PVC end cap for 25 mm pipe
180
PVC pipe clip for 25 mm pipe
182
PVC pipe, diameter 25 mm
179
PVC sleeve for 25 mm pipe
180
PVC T-piece for 25 mm pipe
179
PVC T-piece with opening
180
R
19” rack mounting kit for SZI 192 detector zones
18
Rate-of-rise detector IQ8Quad Ex (i)
86
Rate-of-rise heat detector IQ8Quad
75
Refurbishment zone transponder RZT / 12 V
129
Refurbishment zone transponder RZT 8000
129
3-relay common fault module
21
3-relay module
20
4-relay module
20
Relay controller set
154
8000 FACP remote serial essernet interface
51
Remote indicator for conventional detector series 9000, red
lens207
Remote indicator for detector series 9000, 9200 and
IQ8Quad, red lens
207
Remote indicator for detector series 9200 and IQ8Quad,
blue lens
208
Remote indicator for detector series 9200 and IQ8Quad,
red lens
208
Replacement air filter pads for 801544.10
176
Replacement filter element for 801600
177
Reset module for hat rail mounting
185
Reset module for Titanus EB detectors
177
Keyword
Reset module with mounting bracket
Rotary door magnet with release button, 490 N
RS 232/TTY serial interface module
Page
1
185
214
20
2
S
3
Sensor cable, black
151
Sensor cable connectors for FO cable 970150
157
Sensor cable connectors for FO cable 970153
157
Sensor cable (PVC), blue
151
Sensor cable with steel braiding, black
151
Serial connecting cable for 789862
27
Serial essernet interface EDP, bidirectional
51
Serial essernet interface EDP, unidirectional
50
Service key for electronic module (part no. 80490x) 115
Setting tool for anchor installation
156
Smoke capsule for multi-stimulus detector tester
805550/51101
Smoke detector tester
102, 103
Smoke pellets for testing purposes
104
Sound absorber for Titanus EB aspirating smoke detection
systems176
Sounder, red
199
Sounder with low-profile base, red
198
Sounder with low-profile base, white
198
Spare air filter for VESDA aspirating systems
170
Spare battery baton
103
Spare glass pane for MCP housings 70490x, 7048xx and
761694113
Spare glass pane red for MCP housings 7047xx and
7048xx113
Spare key 1D009 for FACP
23
Spare key 801 for FACP
23
Spare key 901 for FACP
23
Special air filter
176
Special painting for IQ8Alarm
197
Special painting IQ8Quad
97
Special painting IQ8Quad detector base
97
Special painting remote indicator 781814
207
Special painting remote indicator 801824
208
Special painting wireless detector base 805593.10
135
Special painting wireless gateway 805594.10
136
Splice-box IP66 for DTS FO cable, stainless steel
156
Splice-box IP67 for DTS FO cable, steel
156
Stainless steel anchor with plastic clamp for DTS cable 155
Stainless steel anchor with stainless steel clamp for DTS
cables156
Standard detector base for IQ8Quad
90
Standard LED remote indicator panel
40
Start/end of line box for LWM-1
152
4
5
6
7
8
9
10
11
12
13
14
15
249
Index
Keyword
Page
Steel anchor with plastic clamp for DTS cables
155
Steel anchor with steel clamp for DTS cables
155
Suction hose set for 25 mm pipe
180
Surface mount housing for small MCP and IQ8FCT, gray,
similar to RAL 7035
132
Surface mount housing for small MCP and TAL, blue,
similar to RAL 5015
131
Surface-mount housing, gray
229
Surface-mount housing, white
229
Surface mount release pushbutton for automatic door
release system, German
219
Surface spacer for protective cover
116
Surge protection module for Line heat detector LWM-1
(761290)224
Switched-mode power supply with cylindrical plug
27
SZI front for 192 detector zones
18
T
Telescopic rod
104
Terminal card for panel 8010, 1 m
30
Terminal card for panel 8010, 2 m
30
Termination sleeve set for sensor cable
151
Terminators for FO cable 970150
157
Terminators for FO cable 970153
157
Test gas for smoke detecetor tester 805582
102
Test gas for smoke detector testers 769870.10 and 769870
104
Test head for heat detector together with battery and
charger103
Three-way ball valve (PVC)
181
tools 8000 PLus equipment starter kit
25
tools 8000 programming software
25
Top-hat rail
226
Transponder housing for top-hat installation rail
226
4inch trim ring and snap-in mounting clips for IQ8Quad
detector base
93
U
UniVario standard base
144
Univ. bracket for F5000 or prism plate 761440/761441 162
Universal gateway for PC (software)
63
USB cable A/B for 789862 field bus & panel interface 26
USB programming cable for extinguishing panel 8010 27
UV flame detector UniVario
142
UV/IR flame detector X 5200
146
V
Venturi air duct housing for IQ8Quad OTblue-LKM
(802379)147
250
www.hls-austria.com
Keyword
Venturi tube for IQ8Quad air duct housing set 781443,
0.6 m
Venturi tube for IQ8Quad air duct housing set 781443,
1.5 m
Venturi tube for IQ8Quad air duct housing set 781443,
2.8 m
VESDAnet™ connection box
148
148
149
169
W
Wall and floor swivel bracket for door magnet 960120,
angled, 300 mm
216
Wall and floor swivel brackt for door magnet 960120,
angled, 150 mm
216
Wall bracket for Fireray Eexd
162
Wall-mounted door magnet with release button, 490 N 214
Weather protection housing for air duct housing set
781443149
Weather protective cover for MCP housings 7047/48xx,
blue115
Weather protective cover for MCP housings 7047/48xx, red
115
WINMAG installation upgrade as of version 6
60
WINMAG license HeiTel video connection
62
WINMAG license MaxPRO VMS
62
WINMAGLite upgrade to WINMAGplus full version
68
WINMAGLite with USB dongle
68
WINMAGplus - 4-monitor support option
65
WINMAGplus - AutoCAD option
65
WINMAGplus control center software - subsequent
upgrade60
WINMAGplus license - access control
61
WINMAGplus license connection server
62
WINMAGplus license - fire detection technology
61
WINMAGplus license - Galaxy Dimension
61
WINMAGplus license - interfacing DEZ 9000
61
WINMAGplus license - intrusion detection technology 60
WINMAGplus license nurse call systems
62
WINMAGplus license - OPC client
63
WINMAGplus license - OPC server
63
WINMAGplus license - rescue route technology/escape
door control
61
WINMAGplus license - RTD
62
WINMAGplus license - video technology
61
WINMAGplus - OEM option
65
WINMAGplus - remote-access package
65
WINMAG replacement dongle USB instead of parallel 60
WINMAG upgrade to WINMAGplus
60
Karadağ Group of Companies
Emniyet Evleri Mah. Yeniçeri Sok. No:17/1
34416 4. Levent - İstanbul - Türkiye
Tel : +90 (212) 280 2781 - 278 2990
Fax : +90 (212) 270 0322 - 264 0823
E - Mail : [email protected]ğ.com.tr
http://www.karadag.com.tr
Part No. 054581.AT.G0
April 2013
Subject to change without notice
©2013 Honeywell International Inc.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement