Product Data Sheet: Rosemount 3051S Series of

Product Data Sheet: Rosemount 3051S Series of
Product Data Sheet
October 2014
00813-0100-4801, Rev TA
Rosemount 3051S Series of Instrumentation
Scalable pressure, flow, and level solutions
Innovation reaching across your operation
With the Rosemount 3051S Series of Instrumentation, you can optimize your operation in these critical
areas: production, quality, energy efficiency, and safety and environment. By leveraging the power of the
scalable Rosemount 3051S across your entire operation, you’ll be able to minimize process variability, gain
greater process insight, reduce maintenance and downtime, and meet regulatory demands. What’s more,
it’s easy for your people to use, ensuring you will realize the full potential of your measurement investment.
Rosemount 3051S Series
October 2014
Rosemount 3051S SuperModule™ Platform
The most advanced pressure, flow, and level measurements

The all-welded hermetic SST design delivers the industry's highest field reliability

Ultra performance provides up to ±0.025% accuracy and 200:1 rangedown

Ultra for Flow performance provides up to ±0.04% of reading and 14:1 flow turndown

15-year stability and 15-year limited warranty

SIL3 Capable: IEC 61508 certified by an accredited 3rd party agency for use in safety
instrumented systems up to SIL 3 [minimum requirement of single use (1oo1) for SIL 2 and
redundant use (1oo2) for SIL 3]
Rosemount 3051S Series selection guide
Rosemount 3051S Coplanar™ differential, gage, or absolute transmitter
See ordering information on page 5.

Coplanar Platform enables integrated manifold, primary element, and seal system solutions

Dual-capacitance Saturn™ sensor technology corrects for overpressure and line pressure
effects

Calibrated spans from 0.1 inH2O to 4000 psi (0,25 mbar to 276 bar)

Available with 316L SST, Alloy C-276, Alloy 400, Tantalum, gold-plated Alloy 400, or
gold-plated 316L SST process isolators
Rosemount 3051S In-Line gage or absolute transmitter
See ordering information on page 15.

Direct threaded connection, manifold or seal system solutions

Piezoresistive sensor technology allows calibrated spans from
0.3 to 10000 psi (20,7 mbar to 689 bar)

Available with 316L SST or Alloy C-276 process isolators
Contents
Rosemount 3051S Coplanar Pressure Transmitter . . . . . . . . 5
Rosemount 3051S/3051SFx (Measurement Type D)/ 3051S ERS
Rosemount 3051S In-Line Pressure Transmitter . . . . . . . . . 15
Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132
Rosemount 3051S MultiVariable Transmitter . . . . . . . . . . . 22
Rosemount 3051S and 3051SMV Wireless Certifications 139
Rosemount 3051SF DP Flowmeters . . . . . . . . . . . . . . . . . . 31
Rosemount 3051SMV/3051SFx (Measurement Type 1-7)
Rosemount 3051S Electronic Remote Sensor (ERS) System 60
Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
Rosemount 3051S Scalable™ Level Transmitter . . . . . . . . . 76
Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
2
www.rosemount.com
October 2014
Rosemount 3051S Series
Rosemount 3051S MultiVariable Transmitter
See ordering information on page 22.

Combines differential pressure, static pressure, and process temperature measurements along
with mass and energy flow in a single device

Compensates for 25+ different variables providing accurate and repeatable flow readings

Customize pressure and temperature compensation for any flow application

Easily configure flow and device parameters with Engineering Assistant™ Software
Rosemount 3051SF DP Flowmeters
See ordering information on page 31.

Integrates the 3051S with Rosemount’s industry leading primary elements to create one
complete flowmeter assembly

Fully assembled, configured and leak tested for out-of-the-box installation

Reduce installed costs by replacing 10 parts traditionally used for a DP Flow installation with
one flowmeter

Reduce straight pipe requirements, lower permanent pressure loss, and achieve accurate
measurement in small line sizes
Rosemount 3051S Electronic Remote Sensor (ERS™) System
See ordering information on page 60.

The industry’s first digital DP Level architecture consists of a single 4-20 mA HART® loop with
two 3051S pressure sensors connected electronically

Unique digital architecture enables stable and repeatable DP Level measurements on tall
vessels, towers, and applications with wide-varying temperatures

Achieve increased process insight and diagnostics with MultiVariable measurements including
DP, Pressure, and Scaled Variable for Tank Level or Volume

Simplify installations and maintenance by eliminating wet or dry legs, heat tracing, and purge systems
Rosemount 3051S Level Transmitter
See ordering information on page 76.

Level transmitters combine world-class 3051S pressure transmitters with direct-mount seals,
all in a single integrated model number

Connect to virtually any process with a comprehensive offering of seal types, sizes, fill fluids,
and diaphragm materials

Combine with an 1199 Remote Mount Seal to form a Tuned-System™ Assembly for a cost
effective, easy-to-install DP Level measurement solution
www.rosemount.com
3
Rosemount 3051S Series
October 2014
Advanced functionality
WirelessHART® (IEC 62591) capabilities
Available on coplanar, in-line, multivariable, DP flowmeters and level transmitters

Quickly deploy new pressure, level and flow measurements in 70% less time

Eliminate wiring design and construction complexities to lower costs by 40 - 60%

Reduce pipe penetrations and impulse piping with industry-leading MultiVariable technology

Extended range antenna capabilities provide access to remote locations

Delivering over a decade of maintenance free performance with 15-year stability and 10-year
power module life
Advanced diagnostic capabilities
Available on coplanar, in-line, DP flowmeters and level transmitters

Provides diagnostic coverage from the process to the transmitter to the host

Prevent on-scale failures by diagnosing electrical loop issues with Power Advisory diagnostics

Statistical Process Monitoring detects abnormal process conditions enabling more productive
and safer operations

Extend diagnostic coverage to Safety Instrumented Systems with IEC 61508 SIL 2/3 capable
rating
Remote display and interface
Available on coplanar, in-line, DP flowmeters, electronic remote sensors, and level
transmitters

Direct mount to the process and access transmitter capabilities and diagnostics at grade

Get access up to 100 feet (30 m) away from the process to ensure personnel safety

Eliminate the need for impulse lines for best practice installations
Rosemount Instrument Manifolds
Available on traditional, coplanar, and in-line transmitters

Designed and engineered to provide optimal performance with Rosemount 3051S Transmitters

Reduce cost and leak points with flangeless coplanar design

Fully integrated manifold and transmitter assemblies come fully leak checked, calibrated and
assembled allowing for one purchase order to save time and cost

Rosemount manifolds provide a wide variety of styles, materials, and configurations to fit any
process
4
www.rosemount.com
October 2014
Rosemount 3051S Series
Rosemount 3051S Coplanar Pressure Transmitter
Rosemount 3051S Coplanar Pressure Transmitters are the industry leader for differential,
gage, and absolute pressure measurement. The Coplanar Platform allows seamless
integration with manifolds, primary elements, and seal solutions. Capabilities include:
3051S Coplanar Pressure
Transmitter

Ultra, Ultra for Flow, and Classic Performance

4-20 mA HART, Wireless, FOUNDATION™ fieldbus protocols

Safety Certification (Option Code QT)

Advanced Diagnostics (Option Code DA2)

Remote Display and Interface (Option Code M7, M8, or M9)
Additional Information
Specifications: page 107
Certifications: page 132
Dimensional drawings: page 145
Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See
page 127 for more information on Material Selection.
Table 1. Rosemount 3051S Scalable Coplanar Pressure Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model
Transmitter type
3051S
Scalable Pressure Transmitter
Performance class(1)
1
Ultra: 0.025 percent span accuracy, 200:1 rangedown, 15-yr stability, 15-yr limited warranty
★
3(2)
Ultra for Flow: 0.04 percent reading accuracy, 200:1 turndown, 15-yr stability, 15-yr limited warranty
★
2
Classic: 0.035 percent span accuracy, 150:1 rangedown, 15-yr stability
★
Connection type
C
★
Coplanar
Measurement type(3)
D
Differential
★
G
Gage
★
A
Absolute
Pressure range
Differential
Gage
1A
-25 to 25 inH2O
(-62,16 to 62,16 mbar)
-25 to 25 inH2O (-62,16 to 62,16 mbar) 0 to 30 psia (0 to 2,06 bar)
★
2A
-250 to 250 inH2O
(-621,60 to 621,60 mbar)
-250 to 250 inH2O (-621,60 to
621,60 mbar)
0 to 150 psia (0 to 10,34 bar)
★
3A
-1000 to 1000 inH2O
(-2,48 to 2,48 bar)
-393 to 1000 inH2O (-0,97 to 2,48 bar)
0 to 800 psia (0 to 55,15 bar)
★
www.rosemount.com
Absolute
5
Rosemount 3051S Series
October 2014
Table 1. Rosemount 3051S Scalable Coplanar Pressure Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
4A
-300 to 300 psi
(-20,68 to 20,68 bar)
-14.2 to 300 psig (-0,97 to 20,68 bar)
5A
-2000 to 2000 psi
(-137,89 to 137,89 bar)
-14.2 to 2000 psig (-0,97 to 137,89 bar) N/A
0A(4)
-3 to 3 inH2O
(-7,46 to 7,46 mbar)
N/A
0 to 4000 psia (0 to 275,79 bar)
★
★
0 to 5 psia (0 to 0,34 bar)
Isolating diaphragm
2(5)
316L SST
★
3
Alloy C-276
★
4(5)
Alloy 400
(6)
5
Tantalum
6(5)
Gold-Plated Alloy 400 (includes Graphite-Filled PTFE O-ring)
7(5)
Gold-Plated 316L SST
(5)
Materials of construction
Process connection
Size
Flange
material
Drain vent
Bolting
000
None (no process flange)
★
A11(7)
Assemble to Rosemount 305 Integral Manifold
★
A12(7)
Assemble to Rosemount 304 or AMF Manifold and SST traditional flange
★
A15
Assemble to Rosemount 304 or AMF manifold to SST Traditional Flange with Alloy C-276 Drain Vents
★
A16(7)
Assemble to 304 or AMF Manifold to DIN SST Traditional Flange
★
A22
Assemble AMF manifold to SST Coplanar Flange
★
B11(7)(8)(9)
Assemble to one Rosemount 1199 Seal
SST
★
B12(7)(8)(9)
Assemble to two Rosemount 1199 Seals
SST
★
C11(7)
Assemble to Rosemount 405C or 405P Primary Element
★
D11(7)
Assemble to Rosemount 1195 integral orifice and Rosemount 305 Integral Manifold
★
EA2(7)
Assemble to Rosemount 485 or 405A Annubar®
Primary Element with Coplanar flange
SST
316 SST
★
EA3(7)
Assemble to Rosemount 485 or 405A Annubar Primary
Element with Coplanar flange
Cast C-276
Alloy C-276
★
EA5(7)
Assemble to Rosemount 485 or 405A Annubar Primary
Element with Coplanar flange
SST
Alloy C-276
★
E11
Coplanar flange
1
CS
316 SST
★
E12
Coplanar flange
1
SST
316 SST
★
E13(5)
Coplanar flange
1
Cast C-276
Alloy C-276
★
E14
Coplanar flange
1/4–18 NPT
Cast Alloy 400
Alloy 400/K-500
★
E15(5)
Coplanar flange
1
SST
Alloy C-276
★
E16(5)
Coplanar flange
1
CS
Alloy C-276
★
6
/4–18 NPT
/4–18 NPT
/4–18 NPT
/4–18 NPT
/4–18 NPT
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 1. Rosemount 3051S Scalable Coplanar Pressure Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
E21
Coplanar flange
RC 1/4
CS
316 SST
★
E22
Coplanar flange
RC 1/4
SST
316 SST
★
E23(5)
Coplanar flange
RC 1/4
Cast C-276
Alloy C-276
★
E24
Coplanar flange
RC /4
Cast Alloy 400
Alloy 400/K-500
★
E25(5)
Coplanar flange
RC 1/4
SST
Alloy C-276
★
E26(5)
Coplanar flange
RC 1/4
CS
Alloy C-276
★
F12
Traditional flange
1
SST
316 SST
★
F13(5)
Traditional flange
1
Cast C-276
Alloy C-276
★
Traditional flange
1
Cast Alloy 400
Alloy 400/K-500
★
F15
Traditional flange
1
SST
Alloy C-276
★
F22
Traditional flange
RC 1/4
SST
316 SST
★
F14
(5)
1
/4–18 NPT
/4–18 NPT
/4–18 NPT
/4–18 NPT
F23(5)
Traditional flange
RC /4
Cast C-276
Alloy C-276
★
F24
Traditional flange
RC 1/4
Cast Alloy 400
Alloy 400/K-500
★
F25(5)
Traditional flange
RC 1/4
SST
Alloy C-276
★
F52
DIN-compliant traditional
flange
1
SST
316 SST
G11
Vertical mount level flange
2-in. ANSI class 150
SST
316 SST
★
G12
Vertical mount level flange
2-in. ANSI class 300
SST
316 SST
★
G21
Vertical mount level flange
3-in. ANSI class 150
SST
316 SST
★
G22
Vertical mount level flange
3-in. ANSI class 300
SST
316 SST
★
G31
Vertical mount level flange
DIN- DN 50 PN 40
SST
316 SST
★
G41
Vertical mount level flange
DIN- DN 80 PN 40
SST
316 SST
★
Bottom vent traditional flange
1
SST
316 SST
F42
Bottom vent traditional flange
RC 1/4
SST
316 SST
F62
DIN-compliant traditional
flange
1
SST
316 SST
M10 bolting
F72
DIN-compliant traditional
flange
1
SST
316 SST
M12 bolting
F32
1
/4–18 NPT
/4–18 NPT
/4–18 NPT
/4–18 NPT
7
/16-in. bolting
★
Transmitter output
4–20 mA with digital signal based on HART protocol
★
F
FOUNDATION fieldbus protocol
★
X(11)
Wireless (requires wireless options and wireless PlantWeb™ housing)
★
A
(10)
www.rosemount.com
7
Rosemount 3051S Series
October 2014
Table 1. Rosemount 3051S Scalable Coplanar Pressure Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Housing style
00
Material
Conduit
entry size
★
★
None (SuperModule spare part, order output code A)
1A
PlantWeb housing
Aluminum
1
1B
PlantWeb housing
Aluminum
M20 x 1.5
★
PlantWeb housing
SST
1
★
PlantWeb housing
SST
M20 x 1.5
★
Wireless PlantWeb housing
Aluminum
1
★
Wireless PlantWeb housing
SST
1
★
★
1J
1K
5A
(12)
5J(12)
/2–14 NPT
/2–14 NPT
/2–14 NPT
/2–14 NPT
2A
Junction Box housing
Aluminum
1
2B
Junction Box housing
Aluminum
M20 x 1.5
★
★
/2–14 NPT
2J
Junction Box housing
SST
1/2–14 NPT
2E
Junction Box housing with output for remote display and interface
Aluminum
1/2–14 NPT
★
2F
Junction Box housing with output for remote display and interface
Aluminum
M20 x 1.5
★
2M
Junction Box housing with output for remote display and interface
SST
1/2–14 NPT
★
7J(13)
Quick Connect (A size Mini, 4-pin male termination)
SST
1C
PlantWeb housing
Aluminum
G1/2
1L
PlantWeb housing
SST
G1/2
2C
Junction Box housing
Aluminum
G1/2
2G
Junction Box housing with output for remote display and interface
Aluminum
G1/2
★
Wireless options (Requires option code X and wireless PlantWeb housing)
Update rate
WA
User Configurable Update Rate
★
Operating frequency and protocol
3
2.4 GHz DSSS, IEC 62591 (WirelessHART)
★
Omni-directional wireless antenna
WK
External Antenna
★
WM
Extended Range, External Antenna
★
WJ
Remote Antenna
WN
High-Gain, Remote Antenna
SmartPower™
1(14)
8
Adapter for Black Power Module (I.S. Power Module Sold Separately)
★
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 1. Rosemount 3051S Scalable Coplanar Pressure Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Other options (include with selected model number)
Extended product warranty
WR3
3-year limited warranty
★
WR5
5-year limited warranty
★
PlantWeb control functionality
A01(15)
FOUNDATION fieldbus Advanced Control Function Block Suite
★
PlantWeb diagnostic functionality
D01(15)
FOUNDATION fieldbus Diagnostics Suite
★
DA2(15)(16)
Advanced HART Diagnostics Suite
★
PlantWeb enhanced measurement functionality
H01(15)(17)
FOUNDATION fieldbus Fully Compensated Mass Flow Block
★
Mounting bracket(18)
B4
Coplanar flange bracket, all SST, 2-in. pipe and panel
★
B1
Traditional flange bracket, CS, 2-in. pipe
★
B2
Traditional flange bracket, CS, panel
★
B3
Traditional flange flat bracket, CS, 2-in. pipe
★
B7
Traditional flange bracket, B1 with SST bolts
★
B8
Traditional flange bracket, B2 with SST bolts
★
B9
Traditional flange bracket, B3 with SST bolts
★
BA
Traditional flange bracket, B1, all SST
★
BC
Traditional flange bracket, B3, all SST
★
Software configuration
C1(19)
Custom software configuration (requires Configuration Data Sheet)
★
C2
Custom flow configuration (requires H01 and Configuration Data Sheet)
★
Gage pressure calibration
Gage pressure calibration on Rosemount 3051S_CA4 only
★
C4(15)(19)
NAMUR alarm and saturation levels, high alarm
★
C5(15)(19)
NAMUR alarm and saturation levels, low alarm
★
C6(15)(19)
Custom alarm and saturation signal levels, high alarm (requires C1 and Configuration Data Sheet)
★
C7(15)(19)
Custom alarm and saturation signal levels, low alarm (requires C1 and Configuration Data Sheet)
★
C8(15)(19)
Low alarm (standard Rosemount alarm and saturation levels)
★
C3
Alarm limit
www.rosemount.com
9
Rosemount 3051S Series
October 2014
Table 1. Rosemount 3051S Scalable Coplanar Pressure Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Hardware adjustments
D1(15)(19)(20)
Hardware adjustments (zero, span, alarm, security)
★
Flange adapter
D2(21)
D9
(21)
1
/2-14 NPT flange adapter
★
RC1/2 SST flange adapter
Custody transfer
D3(22)
Measurement Canada Accuracy Approval
★
Ground screw
D4(23)
External ground screw assembly
★
Drain/vent valve
D5(21)
Delete transmitter drain/vent valves (install plugs)
D7(21)
SST Coplanar flange without drain/vent ports
★
Conduit plug
DO(24)
316 SST Conduit Plug
★
Product certifications(25)
E1
ATEX Flameproof
★
I1
ATEX Intrinsic Safety
★
IA
ATEX FISCO Intrinsic Safety (FOUNDATION fieldbus protocol only)
★
N1
ATEX Type n
★
K1
ATEX Flameproof, Intrinsic Safety, Type n, Dust
★
ND
ATEX Dust
★
E4
TIIS Flameproof
★
I4(12)
TIIS Intrinsic Safety
★
E5
FM Explosion-proof, Dust Ignition-proof
★
I5
FM Intrinsically Safe; Nonincendive
★
IE
FM FISCO Intrinsically Safe (FOUNDATION fieldbus protocol only)
★
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
★
E6(26)
CSA Explosion-proof, Dust Ignition-proof, Division 2
★
I6
CSA Intrinsically Safe
★
IF
CSA FISCO Intrinsically Safe (FOUNDATION fieldbus protocol only)
★
K6(26)
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
★
E7
IECEx Flameproof, Dust
★
I7
IECEx Intrinsic Safety
★
IG
IECEx FISCO Intrinsic Safety (FOUNDATION fieldbus protocol only)
★
10
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 1. Rosemount 3051S Scalable Coplanar Pressure Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
N7
IECEx Type n
★
K7
IECEx Flameproof, Dust, Intrinsic Safety, Type n
★
E2
INMETRO Flameproof
★
I2
INMETRO Intrinsic Safety
★
IB
INMETRO FISCO Intrinsic Safety
★
K2
INMETRO Flameproof, Intrinsic Safety
★
E3
China Flameproof
★
I3
China Intrinsic Safety
★
N3
China Type n
★
EP
Korea Flameproof
★
IP
Korea Intrinsic Safety
★
KP
Korea Flameproof, Intrinsic Safety
★
EM
Technical Regulations Customs Union (EAC) Flameproof
★
IM
Technical Regulations Customs Union (EAC) Intrinsic Safety
★
KM
Technical Regulations Customs Union (EAC) Flameproof, Intrinsic Safety
★
KA(26)
ATEX and CSA Flameproof, Intrinsically Safe, Division 2
★
KB(26)
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
★
KC
FM and ATEX Explosion-proof, Intrinsically Safe, Division 2
★
KD(26)
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe
★
KG
FM, CSA, ATEX and IECEx FISCO Intrinsic Safety
★
Shipboard approvals
SBS
American Bureau of Shipping
★
SBV
Bureau Veritas (BV) Type Approval
★
SDN
Det Norske Veritas (DNV) Type Approval
★
SLL
Lloyds Register (LR) Type Approval
★
Sensor fill fluid
L1(27)
Inert sensor fill fluid
★
Graphite-filled PTFE O-ring
★
O-ring
L2
Bolting material
L4(21)
Austenitic 316 SST bolts
★
L5(21)
ASTM A 193, Grade B7M bolts
★
L6(21)
Alloy K-500 bolts
★
L7(21)(28)
ASTM A453, Class D, Grade 660 bolts
★
L8(21)
ASTM A193, Class 2, Grade B8M bolts
★
www.rosemount.com
11
Rosemount 3051S Series
October 2014
Table 1. Rosemount 3051S Scalable Coplanar Pressure Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Display type(29)
M5
PlantWeb LCD display
★
M7(15)(30)(31)
Remote mount LCD display and interface, PlantWeb housing, no cable, SST bracket
★
M8(15)(30)
Remote mount LCD display and interface, PlantWeb housing, 50 ft. (15 m) cable, SST bracket
★
M9(15)(30)
Remote mount LCD display and interface, PlantWeb housing, 100 ft. (31 m) cable, SST bracket
★
Pressure testing
P1(32)
Hydrostatic testing with certificate
Special cleaning
P2(21)
Cleaning for special services
P3(21)
Cleaning for less than 1PPM chlorine/fluorine
Maximum static line pressure
P9
4500 psig (310 bar) static pressure limit (Rosemount 3051S_CD only)
★
P0(33)
6092 psig (420 bar) static pressure limit (Rosemount 3051S2CD only)
★
Calibration certification
Q4
Calibration certificate
★
QP
Calibration certificate and tamper evident seal
★
Material traceability certification
Q8
Material traceability certification per EN 10204 3.1
★
Quality certification for safety
QS(15)(19)
Prior-use certificate of FMEDA Data
★
QT(34)
Safety-certified to IEC 61508 with certificate of FMEDA data
★
Transient protection
T1(35)(36)
★
Transient terminal block
Drinking water approval
DW(37)
★
NSF Drinking Water Approval
Surface finish certification
Q16
Surface finish certification for sanitary remote seals
★
Toolkit total system performance reports
QZ
Remote Seal System Performance Calculation Report
★
Conduit electrical connector
GE(38)
(38)
GM
12
M12, 4-pin, Male Connector (eurofast®)
★
®
A size Mini, 4-pin, Male Connector (minifast )
★
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 1. Rosemount 3051S Scalable Coplanar Pressure Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
NACE certificate
Q15(39)
Q25
(39)
Certificate of Compliance to NACE MR0175/ISO 15156 for wetted materials
★
Certificate of Compliance to NACE MR0103 for wetted materials
★
Typical model number:
3051S1CD 2A 2 E12 A 1A DA2 B4 M5
(1) For detailed specifications see “Specifications” on page 107.
(2) This option is only available with range codes 2A and 3A, 316L SST or Alloy C-276 isolating diaphragm and silicone fill fluid.
(3) Performance Class code 3 is available with Measurement Type code D only.
(4) 3051S_CD0 is only available with SST traditional flange, 316L SST diaphragm material, and Bolting option L4.
(5) Materials of Construction comply with metallurgical requirements highlighted within NACE MR0175/ISO 15156 for sour oil field production environments.
Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining
environments. Order with Q15 or Q25 to receive a NACE certificate.
(6) Tantalum diaphragm material is only available for ranges 2A - 5A, differential and gage.
(7) “Assemble to” items are specified separately and require a completed model number. Process connection option codes B12, C11, D11, EA2, EA3, and EA5 are
only available on differential Measurement Type, code D.
(8) Consult an Emerson Process Management representative for performance specifications.
(9) Not available with Performance Class code 3.
(10) Requires PlantWeb™ housing.
(11) Only intrinsically safe approval codes apply.
(12) Only available with output code X.
(13) Available with output code A only. Available approvals are FM Intrinsically Safe; Nonincendive (option code I5), CSA Intrinsically Safe (option code I6), ATEX
Intrinsic Safety (option code I1), or IECEx Intrinsic Safety (option code I7). Contact an Emerson Process Management representative for additional information.
(14) Long-Life Power Module must be shipped separately, order Power Module 701PBKKF.
(15) Not available with output code X.
(16) Requires PlantWeb housing and output code A. Includes Hardware Adjustments as standard.
(17) Requires Rosemount Engineering Assistant to configure.
(18) For process connection option code A11, the mounting bracket must be ordered as part of the manifold model number.
(19) Not available with output code F.
(20) Not available with housing style codes 00, 2E, 2F, 2G, 2M, 5A, 5J, or 7J.
(21) Not available with process connection option code A11.
(22) Requires PlantWeb housing and Hardware Adjustments option code D1. Limited availability depending on transmitter type and range. Contact an Emerson
Process Management representative for additional information.
(23) This assembly is included with options EP, KP, E1, N1, K1, ND, E4, E7, N7, K7, E2, E3, KA, KC, KD, IA, IB, IE, IF, IG, KG, T1, K2, N3, EM, and KM.
www.rosemount.com
13
Rosemount 3051S Series
October 2014
(24) Transmitter is shipped with 316 SST conduit plug (uninstalled) in place of standard carbon steel conduit plug.
(25) Valid when SuperModule Platform and housing have equivalent approvals.
(26) Not available with M20 or G ½ conduit entry size.
(27) Only available on differential and gage measurement types. Silicone fill fluid is standard.
(28) Bolts are not considered process wetted. In instances where NACE MR0175/ISO 15156 and NACE MR0103 conformance is required for bolting, L7 is the
recommended bolting option.
(29) Not available with Housing code 7J.
(30) Not available with output code F, option code DA2, or option code QT.
(31) See the 3051S Reference Manual (document number 00809-0100-4801) for cable requirements. Contact an Emerson Process Management representative for
additional information.
(32) P1 is not available with 3051S_CA0.
(33) Requires 316L SST, Alloy C-276, or Gold-plated 316L SST diaphragm material, assemble to Rosemount 305 integral manifold or DIN-compliant traditional flange
process connection, and bolting option L8. Limited to Pressure Range (Differential), ranges 2A – 5A.
(34) Not available with output code F or X. Not available with housing code 7J.
(35) Not available with Housing code 00, 5A, 5J, or 7J.
(36) The T1 option is not needed with FISCO Product Certifications; transient protection is included in the FISCO product certification codes IA, IB, IE, IF, IG, and KG.
(37) Requires 316L SST diaphragm material, glass-filled PTFE O-ring (standard), and Process Connection code E12 or F12.
(38) Not available with Housing code 00, 5A, 5J, or 7J. Available with Intrinsically Safe approvals only. For FM Intrinsically Safe; Nonincendive (option code I5) or FM
FISCO Intrinsically Safe (option code IE), install in accordance with Rosemount drawing 03151-1009. Suitable for use with all IS approvals (I1, I2, I3, I5, I6, I7, IA,
IB, IE, IF, IG, IP, IM, KG).
(39) NACE compliant wetted materials are identified by Footnote 5.
14
www.rosemount.com
October 2014
Rosemount 3051S Series
Rosemount 3051S In-Line Pressure Transmitter
Rosemount 3051S In-Line Pressure Transmitters are the industry leader for Gage and
Absolute pressure measurement. The in-line, compact design allows the transmitter to
be connected directly to a process for quick, easy and cost effective installation.
Capabilities include:
3051S In-Line Pressure
Transmitter

Ultra and Classic Performance

4-20 mA HART, Wireless, FOUNDATION fieldbus protocols

Safety Certification (Option Code QT)

Advanced Diagnostics (Option Code DA2)

Remote Display and Interface (Option Code M7, M8, or M9)
Additional information
Specifications: page 107
Certifications: page 132
Dimensional Drawings: page 147
Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See
page 127 for more information on Material Selection.
Table 2. Rosemount 3051S Scalable In-Line Pressure Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model
Transmitter type
3051S
Scalable Pressure Transmitter
Performance class(1)
1
Ultra: 0.025 percent span accuracy, 200:1 rangedown, 15-yr stability, 15-yr limited warranty
★
2
Classic: 0.035 percent span accuracy, 150:1 rangedown, 15-yr stability
★
Connection type
T
★
In-Line
Measurement type
G
Gage
★
A
Absolute
★
Pressure range
Gage
Absolute
1A
-14.7 to 30 psi (-1,01 to 2,06 bar)
0 to 30 psia (2,06 bar)
★
2A
-14.7 to 150 psi (-1,01 to 10,34 bar)
0 to 150 psia (10,34 bar)
★
3A
-14.7 to 800 psi (-1,01 to 55,15 bar)
0 to 800 psia (55,15 bar)
★
4A
-14.7 to 4000 psi (-1,01 to 275,79 bar)
0 to 4000 psia (275,79 bar)
★
5A
-14.7 to 10000 psi (-1,01 to 689,47 bar)
0 to 10000 psia (689,47 bar)
★
www.rosemount.com
15
Rosemount 3051S Series
October 2014
Table 2. Rosemount 3051S Scalable In-Line Pressure Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Isolating diaphragm
2(2)(3)
3
(2)(3)
316L SST
★
Alloy C-276
★
Process connection
A11(4)
Assemble to Rosemount 306 Integral Manifold
★
B11(4)(5)
Assemble to one Rosemount 1199 Seal
★
E11
1
★
G11
G1/2 A DIN 16288 male (Range 1-4 only)
★
H11
Coned and threaded, compatible with autoclave type F-250-C (Range 5A only)
F11
Non-threaded instrument flange (I-flange) (Range 1-4 only)
/2–14 NPT female
Transmitter output
A
4–20 mA with digital signal based on HART protocol
★
F(6)
FOUNDATION fieldbus protocol
★
X(7)
Wireless (requires wireless options and wireless PlantWeb housing)
★
Housing style
00
Material
Conduit entry
size
★
★
None (SuperModule spare part, order output code A)
1A
PlantWeb housing
Aluminum
1/2–14 NPT
1B
PlantWeb housing
Aluminum
M20 x 1.5
★
1J
PlantWeb housing
SST
1
★
1K
PlantWeb housing
SST
M20 x 1.5
★
Aluminum
1/2–14 NPT
★
★
5A(8)
Wireless PlantWeb housing
/2–14 NPT
5J(8)
Wireless PlantWeb housing
SST
1
2A
Junction Box housing
Aluminum
1
★
2B
Junction Box housing
Aluminum
M20 x 1.5
★
SST
1
★
★
2J
Junction Box housing
/2–14 NPT
/2–14 NPT
/2–14 NPT
2E
Junction Box housing with output for remote display and interface
Aluminum
1
2F
Junction Box housing with output for remote display and interface
Aluminum
M20 x 1.5
★
2M
Junction Box housing with output for remote display and interface
SST
1
★
7J(9)
Quick Connect (A size Mini, 4-pin male termination)
SST
/2–14 NPT
/2–14 NPT
★
1C
PlantWeb housing
Aluminum
G1/2
1L
PlantWeb housing
SST
G1/2
2C
Junction Box housing
Aluminum
G1/2
2G
Junction Box housing with output for remote display and interface
Aluminum
G1/2
16
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 2. Rosemount 3051S Scalable In-Line Pressure Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Wireless options (requires option code X and wireless PlantWeb housing)
Update rate
WA
User Configurable Update Rate
★
Operating frequency and protocol
3
2.4 GHz DSSS, IEC 62591 (WirelessHART)
★
Omni-directional wireless antenna
WJ
Remote Antenna
WK
External Antenna
★
WM
Extended Range, External Antenna
★
WN
High-Gain, Remote Antenna
SmartPower
1(10)
Adapter for Black Power Module (I.S. Power Module Sold Separately)
★
Other options (Include with selected model number)
Extended product warranty
WR3
3-year limited warranty
★
WR5
5-year limited warranty
★
PlantWeb control functionality
A01(11)
FOUNDATION fieldbus Advanced Control Function Block Suite
★
PlantWeb diagnostic functionality
D01(11)
FOUNDATION fieldbus Diagnostics Suite
★
DA2(11)(12)
Advanced HART Diagnostics Suite
★
Mounting bracket
B4
Bracket, all SST, 2-in. pipe and panel
★
Software configuration
C1(13)
Custom software configuration (requires Configuration Data Sheet)
★
C4(11)(13)
NAMUR alarm and saturation levels, high alarm
★
C5(11)(13)
NAMUR alarm and saturation levels, low alarm
★
C6(11)(13)
Custom alarm and saturation signal levels, high alarm (requires C1 and Configuration Data Sheet)
★
C7(11)(13)
Custom alarm and saturation signal levels, low alarm (requires C1 and Configuration Data Sheet)
★
C8(11)(13)
Low alarm (standard Rosemount alarm and saturation levels)
★
Alarm limit
www.rosemount.com
17
Rosemount 3051S Series
October 2014
Table 2. Rosemount 3051S Scalable In-Line Pressure Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Hardware adjustments
D1(11)(13)(14)
Hardware adjustments (zero, span, alarm, security)
★
Custody transfer
D3(15)
Measurement Canada Accuracy Approval
★
Ground screw
D4(16)
External ground screw assembly
★
316 SST Conduit Plug
★
Conduit plug
DO(17)
Product certifications(18)
E1
ATEX Flameproof
★
I1
ATEX Intrinsic Safety
★
IA
ATEX FISCO Intrinsic Safety (FOUNDATION fieldbus protocol only)
★
N1
ATEX Type n
★
K1
ATEX Flameproof, Intrinsic Safety, Type n, Dust
★
ND
ATEX Dust
★
E4
TIIS Flameproof
★
I4(8)
TIIS Intrinsic Safety
★
E5
FM Explosion-proof, Dust Ignition-proof
★
I5
FM Intrinsically Safe; Nonincendive
★
IE
FM FISCO Intrinsically Safe (FOUNDATION fieldbus protocol only)
★
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
★
E6(19)
CSA Explosion-proof, Dust Ignition-proof, Division 2
★
I6
CSA Intrinsically Safe
★
IF
CSA FISCO Intrinsically Safe (FOUNDATION fieldbus protocol only)
★
K6(19)
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
★
E7
IECEx Flameproof, Dust Ignition-proof
★
I7
IECEx Intrinsic Safety
★
IG
IECEx FISCO Intrinsic Safety (FOUNDATION fieldbus protocol only)
★
N7
IECEx Type n
★
K7
IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, Type n
★
E2
INMETRO Flameproof
★
I2
INMETRO Intrinsic Safety
★
IB
INMETRO FISCO Intrinsic Safety
★
K2
INMETRO Flameproof, Intrinsic Safety
★
E3
China Flameproof
★
18
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 2. Rosemount 3051S Scalable In-Line Pressure Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
I3
China Intrinsic Safety
★
N3
China Type n
★
EP
Korea Flameproof
★
IP
Korea Intrinsic Safety
★
KP
Korea Flameproof, Intrinsic Safety
★
EM
Technical Regulations Customs Union (EAC) Flameproof
★
IM
Technical Regulations Customs Union (EAC) Intrinsic Safety
★
KM
Technical Regulations Customs Union (EAC) Flameproof, Intrinsic Safety
★
KA(19)
ATEX and CSA Flameproof, Intrinsically Safe, Division 2
★
KB(19)
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
★
KC
FM and ATEX Explosion-proof, Intrinsically Safe, Division 2
★
KD(19)
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe
★
KG
FM, CSA, ATEX and IECEx FISCO Intrinsic Safety
★
Shipboard approvals
SBS
American Bureau of Shipping
★
SBV
Bureau Veritas (BV) Type Approval
★
SDN
Det Norske Veritas (DNV) Type Approval
★
SLL
Lloyds Register (LR) Type Approval
★
Sensor fill fluid
L1(20)
Inert sensor fill fluid
★
Display type(21)
M5
PlantWeb LCD display
★
M7(11)(22)(23)
Remote mount LCD display and interface, PlantWeb housing, no cable, SST bracket
★
M8(11)(24)
Remote mount LCD display and interface, PlantWeb housing, 50 ft. (15 m) cable, SST bracket
★
Remote mount LCD display and interface, PlantWeb housing, 100 ft. (31 m) cable, SST bracket
★
(11)(24)
M9
Pressure testing
P1
Hydrostatic testing with certificate
Special cleaning
P2(24)
(24)
P3
Cleaning for special services
Cleaning for less than 1PPM chlorine/fluorine
Calibration certification
Q4
Calibration certificate
★
QP
Calibration certificate and tamper evident seal
★
Material traceability certification
Q8
Material traceability certification per EN 10204 3.1
www.rosemount.com
★
19
Rosemount 3051S Series
October 2014
Table 2. Rosemount 3051S Scalable In-Line Pressure Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Quality certification for safety
QS(11)(13)
QT
(25)
Prior-use certificate of FMEDA Data
★
Safety-certified to IEC 61508 with certificate of FMEDA data
★
Transient protection
T1(26)(27)
★
Transient terminal block
Drinking water approval
DW(28)
★
NSF Drinking Water Approval
Surface finish certification
Q16
★
Surface finish certification for sanitary remote seals
Toolkit total system performance reports
QZ
★
Remote Seal System Performance Calculation Report
Conduit electrical connector
GE(29)
M12, 4-pin, Male Connector (eurofast)
★
GM(29)
A size Mini, 4-pin, Male Connector (minifast)
★
NACE certificate
Q15(30)
Certificate of Compliance to NACE MR0175/ISO 15156 for wetted materials
★
Q25(30)
Certificate of Compliance to NACE MR0103 for wetted materials
★
Typical model number:
3051S1TG 2A 2 E11 A 1A DA2 B4 M5
(1) For detailed specifications see “Specifications” on page 107.
(2) Materials of Construction comply with metallurgical requirements highlighted within NACE MR0175/ISO 15156 for sour oil field production environments.
Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining
environments. Order with Q15 or Q25 to receive a NACE certificate.
(3) Isolator diaphragm selection will dictate materials of construction for wetted parts.
(4) “Assemble to” items are specified separately and require a completed model number.
(5) Consult an Emerson Process Management representative for performance specifications.
(6) Requires PlantWeb housing.
(7) Only intrinsically safe approval codes apply.
(8) Only available with output code X.
(9) Only available with output code A. Available approvals are FM Intrinsically Safe; Nonincendive (option code I5), CSA Intrinsically Safe (option code I6), ATEX
Intrinsic Safety (option code I1), or IECEx Intrinsic Safety (option code I7). Contact an Emerson Process Management representative for additional information.
(10) Long-Life Power Module must be shipped separately, order Power Module 701PBKKF.
(11) Not available with output code X.
(12) Requires PlantWeb housing and output code A. Includes Hardware Adjustments as standard.
20
www.rosemount.com
October 2014
Rosemount 3051S Series
(13) Not available with output code F.
(14) Not available with housing style codes 00, 01, 2E, 2F, 2G, 2M, 5A, 5J, or 7J.
(15) Requires PlantWeb housing and Hardware Adjustments option code D1. Limited availability depending on transmitter type and range. Contact an Emerson
Process Management representative for additional information.
(16) This assembly is included with options EP, KP, E1, N1, K1, ND, E4, E7, N7, K7, E2, E3, KA, KC, KD, IA, IB, IE, IF, IG, KG, T1, K2, N3, EM, and KM.
(17) Transmitter is shipped with 316 SST conduit plug (uninstalled) in place of standard carbon steel conduit plug.
(18) Valid when SuperModule Platform and housing have equivalent approvals.
(19) Not available with M20 or G ½ conduit entry size.
(20) Silicone fill fluid is standard.
(21) Not available with Housing code 7J.
(22) Not available with output code F, option code DA2, or option code QT.
(23) See the 3051S Reference Manual (document number 00809-0100-4801) for cable requirements. Contact an Emerson Process Management representative for
additional information.
(24) Not available with process connection option code A11.
(25) Not available with output code F or X. Not available with housing code 7J.
(26) Not available with Housing code 00, 5A, 5J, or 7J.
(27) The T1 option is not needed with FISCO Product Certifications; transient protection is included in the FISCO product certification codes IA, IB, IE, IF, IG, and KG.
(28) Requires 316L SST diaphragm material and Process Connection code E11 or G11.
(29) Not available with Housing code 00, 5A, 5J, or 7J. Available with Intrinsically Safe approvals only. For FM Intrinsically Safe; Nonincendive (option code I5) or FM
FISCO Intrinsically Safe (option code IE), install in accordance with Rosemount drawing 03151-1009. Suitable for use with all IS approvals (I1, I2, I3, I5, I6, I7, IA,
IB, IE, IF, IG, IP, IM, KG).
(30) NACE compliant wetted materials are identified by Footnote 2.
www.rosemount.com
21
Rosemount 3051S Series
October 2014
Rosemount 3051S MultiVariable Transmitter
The Rosemount 3051S MultiVariable Transmitter delivers unprecedented performance
and capabilities by providing superior flow calculations including fully compensated
mass or volume, energy, and totalized flow. Specify the level of compensation that best
matches the application:

Gas, natural gas, and steam measurement: Utilize full compensation (differential
pressure, line pressure, and temperature measurement)

Saturated steam: Utilize differential and line pressure, or differential pressure and
temperature measurement

Liquids: Utilize differential pressure and temperature measurement

Liquids at stable temperatures: Utilize differential pressure measurement

4-20 mA HART, WirelessHART
3051S MultiVariable Transmitter
Additional information
Specifications: page 107
Certifications: page 141
Dimensional drawings: page 145
Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See
page 127 for more information on Material Selection.
Table 3. Rosemount 3051S Scalable MultiVariable Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model
Transmitter type
3051SMV
Scalable MultiVariable Transmitter
Performance class(1)
3051SMV MultiVariable SuperModule, Measurement Types 1 and 2
3(2)
Ultra for Flow: 0.04% reading DP accuracy, 200:1 rangedown,10-year stability, 15-year limited warranty
★
5
Classic MV: 0.04% span DP accuracy, 100:1 rangedown, 5-year stability
★
3051SMV Single Variable SuperModule, Measurement Types 3 and 4
1(3)
Ultra: 0.025% span DP accuracy, 200:1 rangedown, 15-year stability, 15-year limited warranty
★
2
Classic: 0.035% span DP accuracy, 150:1 rangedown, 15-year stability
★
3(2)
Ultra for Flow: 0.04% reading DP accuracy, 200:1 rangedown,15-year stability, 15-year limited warranty
★
MultiVariable type
M
Measurement with Fully Compensated Mass and Energy Flow Calculations
★
P
Measurement of Process Variables Only (No Flow Calculations)
★
Measurement type
1
Differential Pressure, Static Pressure, and Temperature
★
2
Differential Pressure and Static Pressure
★
22
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 3. Rosemount 3051S Scalable MultiVariable Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
3
Differential Pressure and Temperature
★
4
Differential Pressure
★
Differential pressure range
0(3)(4)
-3 to 3 inH2O (-7,46 to 7,46 mbar)
★
1
-25 to 25 inH2O (-62,16 to 62,16 mbar)
★
2
-250 to 250 inH2O (-621,60 to 621,60 mbar)
★
3
-1000 to 1000 inH2O (-2,48 to 2,48 bar)
★
4
-150 to 150 psi (-10,34 to 10,34 bar) for Measurement Types 1 & 2; -300 to 300 psi (-20,68 to 20,68 bar) for Types 3 &
4
★
5
-2000 to 2000 psi (-137,89 to 137,89 bar)
★
Static pressure type
N(5)
None
★
A
Absolute
★
G
Gage
★
Static pressure range
Absolute
Gage
N(5)
None
3
Range 3
0.5 to 800 psia (0,03 to 55,15 bar)
-14.2 to 800 psig (-0,98 to 55,15 bar)
★
4(6)
Range 4
0.5 to 3626 psia (0,03 to 250,00 bar)
-14.2 to 3626 psig (-0,98 to 250,00 bar)
★
★
Temperature input
N(7)
None
★
R(8)
RTD Input [Type Pt 100, -328 to 1562 °F (-200 to 850 °C)]
★
Isolating diaphragm
2(9)
316L SST
★
3(9)
Alloy C-276
★
5(10)
Tantalum
7(9)
Gold-Plated 316L SST
Material type
Process connection
Size
Flange
material
Drain vent
Bolting
000
None (no process flange)
★
A11(11)
Assemble to Rosemount 305/306 Integral Manifold
★
A12(11)
Assemble to Rosemount 304 or AMF Manifold with SST Traditional Flange
★
A15
Assemble to Rosemount 304 or AMF manifold to SST Traditional Flange with Alloy C-276 Drain Vents
★
A16(11)
Assemble to 304 or AMF Manifold to DIN SST Traditional Flange
★
A22
Assemble AMF manifold to SST Coplanar Flange
★
www.rosemount.com
23
Rosemount 3051S Series
October 2014
Table 3. Rosemount 3051S Scalable MultiVariable Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
B11(11)(12) Assemble to one Rosemount 1199 Seal
(11)(12)
★
Assemble to two Rosemount 1199 Seals
★
Assemble to Rosemount 405C or 405P Primary Element
★
Assemble to Rosemount 1195 Integral Orifice and Rosemount 305 Integral Manifold
★
EA2(11)
Assemble to Rosemount 485 or 405A Annubar Primary
Element with Coplanar flange
SST
316 SST
★
EA3(11)
Assemble to Rosemount 485 or 405A Annubar Primary
Element with Coplanar flange
Cast C-276
Alloy C-276
★
EA5(11)
Assemble to Rosemount 485 or 405A Annubar Primary
Element with Coplanar flange
SST
Alloy C-276
★
E11
Coplanar flange
1
Carbon Steel
316 SST
★
E12
Coplanar flange
1/4–18 NPT
SST
316 SST
★
E13(9)
Coplanar flange
1
Cast C-276
Alloy C-276
★
B12
C11(11)
D11
(11)
/4–18 NPT
/4–18 NPT
Coplanar flange
1/4–18 NPT
Cast Alloy 400
Alloy 400/K-500
★
E15(9)
Coplanar flange
1/4–18 NPT
SST
Alloy C-276
★
E16(9)
Coplanar flange
1
Carbon Steel
Alloy C-276
★
E21
Coplanar flange
RC 1/4
Carbon Steel
316 SST
★
Coplanar flange
RC 1/4
SST
316 SST
★
E14
E22
/4–18 NPT
E23(9)
Coplanar flange
RC /4
Cast C-276
Alloy C-276
★
E24
Coplanar flange
RC 1/4
Cast Alloy 400
Alloy 400/K-500
★
E25(9)
Coplanar flange
RC 1/4
SST
Alloy C-276
★
E26(9)
1
Coplanar flange
RC /4
Carbon Steel
Alloy C-276
★
F12
Traditional flange
1/4–18 NPT
SST
316 SST
★
F13(9)
Traditional flange
1/4–18 NPT
Cast C-276
Alloy C-276
★
F14
Traditional flange
1
Cast Alloy 400
Alloy 400/K-500
★
Traditional flange
1
SST
Alloy C-276
★
F15(9)
1
/4–18 NPT
/4–18 NPT
F22
Traditional flange
RC /4
SST
316 SST
★
F23(9)
Traditional flange
RC 1/4
Cast C-276
Alloy C-276
★
F24
Traditional flange
RC 1/4
Cast Alloy 400
Alloy 400/K-500
★
★
1
F25(9)
Traditional flange
RC /4
SST
Alloy C-276
F52
DIN-compliant traditional flange
1/4–18 NPT
SST
316 SST
G11
Vertical mount level flange
2-in. ANSI class 150
SST
★
G12
Vertical mount level flange
2-in. ANSI class 300
SST
★
G14
Vertical mount level flange
2-in. ANSI class 150
Cast C-276
★
G15
Vertical mount level flange
2-in. ANSI class 300
Cast C-276
★
G21
Vertical mount level flange
3-in. ANSI class 150
SST
★
G22
Vertical mount level flange
3-in. ANSI class 300
SST
★
G31
Vertical mount level flange
DIN- DN 50 PN 40
SST
★
24
1
7/16-in. bolting
www.rosemount.com
★
October 2014
Rosemount 3051S Series
Table 3. Rosemount 3051S Scalable MultiVariable Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
EB6
Assemble to Primary Element with Manifold and Coplanar Flange, CS, Alloy C-276
F32
Bottom vent traditional flange
1
SST
316 SST
F42
Bottom vent traditional flange
RC 1/4
SST
316 SST
DIN-compliant traditional flange
1
SST
316 SST
M10 bolting
F72
DIN-compliant traditional flange
1
SST
316 SST
M12 bolting
G41
Vertical mount level flange
DIN- DN 80 PN 40
SST
F62
/4–18 NPT
/4–18 NPT
/4–18 NPT
Transmitter output
A
4–20 mA with digital signal based on HART protocol
★
X(13)
Wireless (requires wireless options and wireless PlantWeb housing)
★
Housing style
Material
Conduit entry size
1A
PlantWeb housing
Aluminum
1
★
1B
PlantWeb housing
Aluminum
M20 x 1.5
★
1J
PlantWeb housing
SST
1/2–14 NPT
★
1K
PlantWeb housing
SST
M20 x 1.5
★
★
★
/2–14 NPT
5A(14)
Wireless PlantWeb housing
Aluminum
1/2–14 NPT
5J(14)
Wireless PlantWeb housing
SST
1/2–14 NPT
1C
PlantWeb housing
Aluminum
G1/2
1L
PlantWeb housing
SST
G1/2
Wireless options (requires option code X and wireless PlantWeb housing)
Update rate
WA
★
User configurable update rate
Operating frequency and protocol
3
★
2.4 GHz DSSS, IEC 62591 (WirelessHART)
Omni-directional wireless antenna
WK
External Antenna
★
WM
Extended Range, External Antenna
★
WN
High-Gain, Remote Antenna
SmartPower
1(15)
★
Adapter for Black Power Module (I.S. Power Module sold separately)
Other options (include with selected model number)
Extended product warranty
WR3
3-year limited warranty
★
WR5
5-year limited warranty
★
www.rosemount.com
25
Rosemount 3051S Series
October 2014
Table 3. Rosemount 3051S Scalable MultiVariable Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
RTD cable (RTD sensor must be ordered separately)
C12
RTD Input with 12 ft. (3.66 m) of Shielded Cable
★
C13
RTD Input with 24 ft. (7.32 m) of Shielded Cable
★
C14
RTD Input with 75 ft. (22.86 m) of Shielded Cable
★
C22
RTD Input with 12 ft. (3.66 m) of Armored Shielded Cable
★
C23
RTD Input with 24 ft. (7.32 m) of Armored Shielded Cable
★
C24
RTD Input with 75 ft. (22.86 m) of Armored Shielded Cable
★
C32
RTD Input with 12 ft. (3.66 m) of ATEX/IECEx Flameproof Cable
★
C33
RTD Input with 24 ft. (7.32 m) of ATEX/IECEx Flameproof Cable
★
C34
RTD Input with 75 ft. (22.86 m) of ATEX/IECEx Flameproof Cable
★
Mounting brackets(16)
B4
Coplanar flange bracket, all SST, 2-in. pipe and panel
★
B1
Traditional flange bracket, Carbon Steel, 2-in. pipe
★
B2
Traditional flange bracket, Carbon Steel, panel
★
B3
Traditional flange flat bracket, Carbon Steel, 2-in. pipe
★
B7
Traditional flange bracket, B1 with SST bolts
★
B8
Traditional flange bracket, B2 with SST bolts
★
B9
Traditional flange bracket, B3 with SST bolts
★
BA
Traditional flange bracket, B1, all SST
★
BC
Traditional flange bracket, B3, all SST
★
Software configuration
C1
Custom software configuration
Note: A Configuration Data Sheet must be completed, see document number 00806-0100-4803.
★
C2
Custom flow configuration
Note: A Custom Fluid Data Sheet must be completed, see document number 00806-0200-4803.
★
C4
NAMUR alarm and saturation levels, high alarm
★
C5
NAMUR alarm and saturation levels, low alarm
★
C6
Custom alarm and saturation signal levels, high alarm
★
C7
Custom alarm and saturation signal levels, low alarm
★
C8
Low alarm (standard Rosemount alarm and saturation levels)
★
Flange adapter
D2(17)
1
D9(17)
RC 1/2 SST flange adapter
★
/2-14 NPT flange adapter
Ground screw
D4(18)
26
★
External ground screw assembly
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 3. Rosemount 3051S Scalable MultiVariable Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Drain/vent valve
D5(17)
(17)
D7
★
Delete transmitter drain/vent valves (install plugs)
Coplanar flange without drain/vent ports
Conduit plug
DO(19)
★
316 SST Conduit Plug
Product certifications
E1
ATEX Flameproof
★
I1
ATEX Intrinsic Safety
★
N1
ATEX Type n
★
ND
ATEX Dust
★
K1
ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E1, I1, N1, and ND)
★
E4
TIIS Flameproof
★
E5
FM Explosion-proof, Dust Ignition-proof
★
I5
FM Intrinsically Safe; Nonincendive
★
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of E5 and I5)
★
E6(20)
CSA Explosion-proof, Dust Ignition-proof, Division 2
★
I6
CSA Intrinsically Safe
★
K6(20)
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of E6 and I6)
★
E7
IECEx Flameproof, Dust Ignition-proof
★
I7
IECEx Intrinsic Safety
★
N7
IECEx Type n
★
K7
IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of E7, I7, and N7)
★
E2
INMETRO Flameproof
★
I2
INMETRO Intrinsic Safety
★
E3
China Flameproof
★
I3
China Intrinsic Safety
★
EM
Technical Regulations Customs Union (EAC) Flameproof
★
IM
Technical Regulations Customs Union (EAC) Intrinsic Safety
★
KM
Technical Regulations Customs Union (EAC) Flameproof, Intrinsic Safety
★
KA(20)(21)
ATEX and CSA Explosion-proof, Intrinsically Safe, Division 2 (combination of E1, E6, I1, and I6)
★
KB(20)(21)
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of E5, E6, I5, and I6)
★
KC(21)
FM and ATEX Explosion-proof, Intrinsically Safe, Division 2 (combination of E5, E1, I5, and I1)
★
KD(20)(21)
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe (combination of E5, E6, E1, I5, I6, and I1)
★
Drinking water approval
DW(22)
★
NSF Drinking Water Certification
www.rosemount.com
27
Rosemount 3051S Series
October 2014
Table 3. Rosemount 3051S Scalable MultiVariable Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Shipboard approvals
SBS
American Bureau of Shipping
★
SBV
Bureau Veritas (BV) Type Approval
★
SDN
Det Norske Veritas (DNV) Type Approval
★
SLL
Lloyds Register (LR) Type Approval
★
Alternate materials of construction
L1
Inert sensor fill fluid (Differential and Gage sensors only) Note: Silicone fill fluid is standard.
★
L2
Graphite-filled PTFE O-ring
★
L4(17)
Austenitic 316 SST bolts
★
L5(17)
ASTM A193, Grade B7M bolts
★
L6(17)
Alloy K-500 bolts
★
L7(17)(23)
ASTM A453, Class D, Grade 660 bolts
★
L8(17)
ASTM A193, Class 2, Grade B8M bolts
★
Digital display
M5
★
PlantWeb LCD display
Wireless assembly options
WTA
Integral assembly to Smart Wireless 775 THUM™ Adapter (Specified Separately)
★
Special procedures
P1(24)
Hydrostatic testing with certificate
★
P9(3)
4500 psig (310 bar) static pressure limit
★
P0(3)(25)
6092 psig (420 bar) static pressure limit
★
P2(17)
Cleaning for special services
P3(17)
Cleaning for less than 1PPM chlorine/fluorine
Special certifications
Q4
Calibration Certificate
★
QP
Calibration Certificate and Tamper Evident Seal
★
Q8
Material Traceability Certification per EN 10204 3.1B
★
Q16
Surface Finish Certification for Sanitary Remote Seals
★
QZ
Remote Seal System Performance Calculation Report
★
Transient protection
T1
★
Transient terminal block
Conduit electrical connector
GE(26)
M12, 4-pin, Male Connector (eurofast)
★
GM(26)
A size Mini, 4-pin, Male Connector (minifast)
★
28
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 3. Rosemount 3051S Scalable MultiVariable Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
NACE certificate
Q15(27)
(27)
Q25
Certificate of Compliance to NACE MR0175/ISO 15156 for wetted materials
★
Certificate of Compliance to NACE MR0103 for wetted materials
★
Cold temperature
BRR
★
-58 °F (-50 °C) Cold Temperature Start-up
Typical model number:
3051SMV 3 M 1 2 G 4 R 2 E12 A 1A B4 C2 M5
(1) For detailed specifications see “Specifications” on page 107.
(2) For Measurement Types 1 & 2, only available with DP range codes 2, 3, and 4, 316L SST and Alloy C-276 isolating diaphragm and silicone fill fluid.
For Measurements Types 3 & 4, only available with DP range codes 2 and 3, 316L SST and Alloy C-276 isolating diaphragm and silicone fill fluid.
(3) Only available with Measurement Type codes 3 and 4.
(4) DP Range 0 is only available with traditional flange, 316L SST diaphragm material, and Bolting option L4.
(5) Required for Measurement Type codes 3 and 4.
(6) For Measurement Type codes 1 and 2 with DP range 1, absolute limits are 0.5 to 2000 psi (0,03 to 137,9 bar) and gage limits are -14.2 to 2000 psig
(-0,98 to 137,9 bar).
(7) Required for Measurement Type codes 2 and 4.
(8) Required for Measurement Type codes 1 and 3. RTD Sensor must be ordered separately.
(9) Materials of Construction comply with metallurgical requirements highlighted within NACE MR0175/ISO 15156 for sour oil field production environments
Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
Order with Q15 or Q25 to receive a NACE certificate.
(10) Tantalum diaphragm material is only available for DP ranges 2-5.
(11) “Assemble to” items are specified separately and require a completed model number.
(12) Consult an Emerson Process Management representative for performance specifications.
(13) Only available with Measurement Type 2 and MultiVariable Type P.
(14) Only available with output code X.
(15) Long-Life Power Module must be shipped separately, order Power Module 701PBKKF.
(16) For process connection option code A11, the mounting bracket must be ordered as part of the manifold model number.
(17) Not available with process connection option code A11.
(18) This assembly is included with certification options EP, KP, E1, N1, K1, ND, E4, E7, N7, K7, E2, E3, KA, KC, KD, EM, KM.
(19) Transmitter is shipped with 316 SST conduit plug (uninstalled) in place of standard carbon steel conduit plug.
(20) Not available with M20 or G ½ conduit entry size.
(21) RTD cable not available with this option.
(22) Requires 316L SST diaphragm material, glass-filled PTFE O-ring (standard), and Process Connection code E12 or F12.
(23) Bolts are not considered process wetted. In instances where NACE MR0175/ISO 15156 and NACE MR0103 conformance is required for bolting, L7 is the recommended
bolting option.
www.rosemount.com
29
Rosemount 3051S Series
October 2014
(24) Not available with DP range 0.
(25) Requires 316L SST or Alloy C-276 diaphragm material, assemble to Rosemount 305 Integral Manifold or DIN-compliant traditional flange process connection, and
bolting option L8. Limited to differential pressure ranges 2-5.
(26) Available with Intrinsically Safe approvals only. For FM Intrinsically Safe; Nonincendive approval (option code I5), install in accordance with Rosemount drawing
03151-1009.
(27) NACE compliant wetted materials are identified by Footnote 9.
30
www.rosemount.com
October 2014
Rosemount 3051S Series
Rosemount 3051SF DP Flowmeters
Rosemount 3051SF Flowmeters integrate the 3051S with industry leading primary
elements. Capabilities include:
3051SFC
3051SFA
3051SFP

Flowmeters are factory configured to meet your application needs (Configuration Data
Sheet required)

MultiVariable capabilities allow scalable flow compensation
(Measurement Types 1-4)

4-20 mA HART, Wireless, and FOUNDATION fieldbus protocols

Ultra for Flow for improved flow performance across wider flow ranges

Integral temperature measurement (Option Code T)

Advanced Diagnostics (Option Code DA2)

Direct or remote mount configurations available
Additional information
Specifications: page 107
Dimensional drawings: page 152
Rosemount 3051SFA Annubar Flowmeter

Annubar flowmeters reduce permanent pressure loss by creating less blockage in the pipe

Ideal for large line size installations when cost, size and weight of the flowmeter are concerns
Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See
page 127 for more information on Material Selection.
Table 4. Rosemount 3051SFA Annubar Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model
3051SFA
Product description
Annubar Flowmeter
Measurement
type
• = Available
— = Unavailable
D
1-7
•
•
Measurement type
1
Fully Compensated Mass & Energy Flow Calculations – Differential & Static Pressures w/
Temperature
—
•
★
2
Compensated Flow Calculations – Differential & Static Pressures
—
•
★
3
Compensated Flow Calculations – Differential Pressure & Temperature
—
•
★
4
Compensated Flow Calculations – Differential Pressure
—
•
★
D
Differential Pressure
•
—
★
www.rosemount.com
31
Rosemount 3051S Series
October 2014
Table 4. Rosemount 3051SFA Annubar Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
5
Process Variables Only (No Flow Calculations) – Differential & Static Pressures w/
Temperature
—
•
6
Process Variables Only (No Flow Calculations) – Differential & Static Pressures
—
•
7
Process Variables Only (No Flow Calculations) – Differential Pressure & Temperature
—
•
D
1-7
Fluid type
L
Liquid
•
•
★
G
Gas
•
•
★
S
Steam
•
•
★
020
2-in. (50 mm)
•
•
★
025
21/2-in. (63.5 mm)
•
•
★
030
3-in. (80 mm)
•
•
★
035
31/2-in. (89 mm)
•
•
★
040
4-in. (100 mm)
•
•
★
050
5-in. (125 mm)
•
•
★
060
6-in. (150 mm)
•
•
★
070
7-in. (175 mm)
•
•
★
080
8-in. (200 mm)
•
•
★
100
10-in. (250 mm)
•
•
★
120
12-in. (300 mm)
•
•
★
140
14-in. (350 mm)
•
•
160
16-in. (400 mm)
•
•
180
18-in. (450 mm)
•
•
200
20-in. (500 mm)
•
•
240
24-in. (600 mm)
•
•
300
30-in. (750 mm)
•
•
360
36-in. (900 mm)
•
•
420
42-in. (1066 mm)
•
•
480
48-in. (1210 mm)
•
•
600
60-in. (1520 mm)
•
•
720
72-in. (1820 mm)
•
•
780
78-in. (1950 mm)
•
•
840
84-in. (2100 mm)
•
•
900
90-in. (2250 mm)
•
•
960
96-in. (2400 mm)
•
•
Line size
32
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 4. Rosemount 3051SFA Annubar Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Pipe I.D. range
D
1-7
C
Range C from the Pipe I.D. table
•
•
★
D
Range D from the Pipe I.D. table
•
•
★
A
Range A from the Pipe I.D. table
•
•
B
Range B from the Pipe I.D. table
•
•
E
Range E from the Pipe I.D. table
•
•
Z
Non-standard Pipe I.D. Range or line sizes greater than 12-in. (300 mm)
•
•
Pipe material/mounting assembly material
C
Carbon steel (A105)
•
•
★
S
316 Stainless Steel
•
•
★
0(1)
No Mounting (customer supplied)
•
•
★
G
Chrome-Moly Grade F-11
•
•
N
Chrome-Moly Grade F-22
•
•
J
Chrome-Moly Grade F-91
•
•
Piping orientation
H
Horizontal Piping
•
•
★
D
Vertical Piping with Downwards Flow
•
•
★
U
Vertical Piping with Upwards Flow
•
•
★
Annubar type
P
Pak-Lok
•
•
★
F
Flanged with opposite side support
•
•
★
L
Flange-Lok
•
•
G
Gear-Drive Flo-Tap
•
•
M
Manual Flo-Tap
•
•
Sensor material
★
S
316 Stainless Steel
•
•
H
Alloy C-276
•
•
1
Sensor size 1 — Line sizes 2-in. (50 mm) to 8-in. (200 mm)
•
•
★
2
Sensor size 2 — Line sizes 6-in. (150 mm) to 96-in. (2400 mm)
•
•
★
3
Sensor size 3 — Line sizes greater than 12-in. (300 mm)
•
•
Sensor size
Mounting type
T1
Compression/Threaded Connection
•
•
★
A1
150# RF ANSI
•
•
★
A3
300# RF ANSI
•
•
★
www.rosemount.com
33
Rosemount 3051S Series
October 2014
Table 4. Rosemount 3051SFA Annubar Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
A6
600# RF ANSI
•
•
★
D1
DN PN16 Flange
•
•
★
D3
DN PN40 Flange
•
•
★
D6
★
DN PN100 Flange
•
•
(2)
900# RF ANSI
•
•
(2)
AF
1500# RF ANSI
•
•
AT(2)
2500 # RF ANSI
•
•
R1
150# RTJ Flange
•
•
R3
300# RTJ Flange
•
•
R6
600# RTJ Flange
•
•
R9(2)
900# RTJ Flange
•
•
RF(2)
1500# RTJ Flange
•
•
RT(2)
2500# RTJ Flange
•
•
D
1-7
•
•
★
A9
Opposite side support or packing gland
0
No opposite side support or packing gland (required for Pak-Lok and Flange-Lok
models)
Opposite Side Support (required for Flanged Models)
C
NPT Threaded Opposite Support Assembly – Extended Tip
•
•
★
D
Welded Opposite Support Assembly – Extended Tip
•
•
★
Packing Gland – Required for Flo-Tap Models
Packing
material
Packing gland material
Rod material
J(3)
Stainless Steel Packing Gland/Cage Nipple
Carbon Steel PTFE
•
•
K(3)
Stainless Steel Packing Gland/Cage Nipple
Stainless
Steel
•
•
L(3)
Stainless Steel Packing Gland/Cage Nipple
Carbon Steel Graphite
•
•
N(3)
Stainless Steel Packing Gland/Cage Nipple
Stainless
Steel
Graphite
•
•
R
Alloy C-276 Packing Gland/Cage Nipple
Stainless
Steel
Graphite
•
•
PTFE
Isolation valve for Flo-Tap Models
0(1)
Not Applicable or Customer Supplied
•
•
1
Gate Valve, Carbon Steel
•
•
2
Gate Valve, Stainless Steel
•
•
5
Ball Valve, Carbon Steel
•
•
6
Ball Valve, Stainless Steel
•
•
34
★
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 4. Rosemount 3051SFA Annubar Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Temperature measurement
D
1-7
T(4)
0
Integral RTD – not available with Flanged model greater than class 600#
•
•
★
(5)
No Temperature Sensor
•
•
★
(4)
Remote Thermowell and RTD
•
•
R
Transmitter connection platform
3
Direct-mount, Integral 3-valve Manifold– not available with Flanged model greater than
class 600
•
•
★
5
Direct -mount, 5-valve Manifold – not available with Flanged model greater than class
600
•
•
★
7
Remote-mount NPT Connections (1/2-in. FNPT)
•
•
★
6
Direct-mount, High Temperature 5-valve Manifold – not available with Flanged model
greater than class 600
•
•
8
Remote-mount SW Connections (1/2-in.)
•
•
Differential pressure range
1
0 to 25 in H2O (0 to 62,16 mbar)
•
•
★
2
0 to 250 in H2O (0 to 621,60 mbar)
•
•
★
3
0 to 1000 in H2O (0 to 2,48 bar)
•
•
★
Static pressure range
A(6)
None
•
•
★
D
Absolute 0 to 800 psia (0 to 55,15 bar)
—
•
★
E(7)
Absolute 0 to 3626 psia (0 to 250,00 bar)
—
•
★
J
Gage -14.2 to 800 psig (-0,98 to 55,15 bar)
—
•
★
K(7)
Gage -14.2 to 3626 psig (-0,98 to 250,00 bar)
—
•
★
Transmitter Output
A
4–20 mA with digital signal based on HART protocol
•
•
★
F
FOUNDATION fieldbus protocol (requires PlantWeb housing)
•
—
★
Wireless (requires wireless options and Wireless PlantWeb housing)
•
—
★
•
—
★
X
(8)(9)
Transmitter housing style
Material
Conduit
entry size
00
None (customer-supplied electrical connection)
1A
PlantWeb housing
Aluminum
1/2-14 NPT
•
•
★
1B
PlantWeb housing
Aluminum
M20 x 1.5
•
•
★
1J
PlantWeb housing
SST
1
/2-14 NPT
•
•
★
1K
PlantWeb housing
SST
M20 x 1.5
•
•
★
2A
Junction Box housing
Aluminum
1/2-14 NPT
•
—
★
2B
Junction Box housing
Aluminum
M20 x 1.5
•
—
★
www.rosemount.com
35
Rosemount 3051S Series
October 2014
Table 4. Rosemount 3051SFA Annubar Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
2E
Junction Box housing with output for remote display
and interface
Aluminum
1
/2-14 NPT
•
—
★
2F
Junction Box housing with output for remote display
and interface
Aluminum
M20 x 1.5
•
—
★
2J
Junction Box housing
SST
1
•
—
★
2M
Junction Box housing with output for remote display
and interface
SST
1
•
—
★
5A(10)
Wireless PlantWeb housing
Aluminum
1
•
—
★
5J(10)
Wireless PlantWeb housing
SST
1
•
—
★
7J(8)(11)
Quick Connect (A size Mini, 4-pin male termination)
★
/2-14 NPT
/2-14 NPT
/2-14 NPT
/2-14 NPT
•
—
1
1C
PlantWeb housing
Aluminum
G /2
•
•
1L
PlantWeb housing
SST
G1/2
•
•
2C
Junction Box housing
Aluminum
G1/2
•
—
2G
Junction Box housing with output for remote display
and interface
Aluminum
G1/2
•
—
D
1-7
Performance class(12)
3051S MultiVariable SuperModule, Measurement Types 1, 2, 5, and 6
3(13)
Ultra for Flow: 0.8% flow rate accuracy, 14:1 flow turndown, 10-year stability, 15-year
limited warranty
•
•
★
5
Classic MV: 1.15% flow rate accuracy, 8:1 flow turndown, 5-yr. stability
—
•
★
3051S Single Variable SuperModule, Measurement Types 3, 4, 7, and D
1
Ultra: up to 0.95% flow rate accuracy, 8:1 flow turndown, 15-year stability, 15-year
limited warranty
•
—
★
2
Classic: up to 1.4% flow rate accuracy, 8:1 flow turndown, 15-year stability
•
—
★
3(13)
Ultra for Flow: 0.8% flow rate accuracy, 14:1 flow turndown, 15-year stability, 15-year
limited warranty
•
•
★
•
—
★
•
—
★
Wireless options (requires option code X and wireless PlantWeb housing)
Update rate, operating frequency and protocol
WA
User Configurable Update Rate
Operating frequency and protocol
3
2.4 GHz DSSS, IEC 62591 (WirelessHART)
Omni-directional wireless antenna
WK
External Antenna
•
—
★
WM
Extended Range, External Antenna
•
—
★
WN
High-Gain, Remote Antenna
•
—
•
—
SmartPower adapter
1(14)
36
Adapter for Black Power Module (I.S. Power Module Sold Separately)
★
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 4. Rosemount 3051SFA Annubar Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Other options (include with selected model number)
Extended product warranty
D
1-7
WR3
3-year limited warranty
•
•
★
WR5
5-year limited warranty
•
•
★
Hydrostatic Testing with Certificate
•
•
Extended Hydrostatic Testing
•
•
Pressure testing
P1(15)
(15)
PX
Special cleaning
P2
Cleaning for Special Services
•
•
PA
Cleaning per ASTM G93 level D (section 11.4)
•
•
•
•
•
•
Material testing
V1
Dye Penetrant Exam
Material examination
V2
Radiographic Examination
Flow calibration
W1
Flow Calibration (Average K)
•
•
WZ
Special Calibration
•
•
Special inspection
QC1
Visual & Dimensional Inspection with Certificate
•
•
★
QC7
Inspection & Performance Certificate
•
•
★
Surface finish
RL
Surface finish for Low Pipe Reynolds Number in Gas & Steam
•
•
★
RH
Surface finish for High Pipe Reynolds Number in Liquid
•
•
★
•
•
★
Material traceability certification
Q8(16)
Material Traceability Certificate per EN 10204:2004 3.1
Code conformance
J2(17)
ANSI / ASME B31.1
•
•
J3(17)
ANSI / ASME B31.3
•
•
•
•
Material conformance
J5(18)
NACE MR-0175 / ISO 15156
www.rosemount.com
37
Rosemount 3051S Series
October 2014
Table 4. Rosemount 3051SFA Annubar Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Country certification
D
1-7
J6
European Pressure Directive (PED)
•
•
J1
Canadian Registration
•
•
★
Installed in flanged pipe spool section
H3
150# Flanged Connection with Rosemount Standard Length and Schedule
•
•
H4
300# Flanged Connection with Rosemount Standard Length and Schedule
•
•
H5
600# Flanged Connection with Rosemount Standard Length and Schedule
•
•
Instrument connections for remote mount option
G2
Needle Valves, Stainless Steel
•
•
★
G6
OS&Y Gate Valve, Stainless Steel
•
•
★
G1
Needle Valves, Carbon Steel
•
•
G3
Needle Valves, Alloy C-276
•
•
G5
OS&Y Gate Valve, Carbon Steel
•
•
G7
OS&Y Gate Valve, Alloy C-276
•
•
Mounting Hardware Shipped Separately
•
•
Attach to Transmitter
•
•
Special shipment
Y1
★
Attach to
H1
Special dimensions
VM
Variable Mounting
•
•
VT
Variable Tip
•
•
VS
Variable length Spool Section
•
•
Transmitter calibration certification
Q4
Calibration Certificate for Transmitter
•
•
★
QP
Calibration Certificate & Tamper Evident Seal
•
•
★
Quality certification for safety
QS(21) (28)
Prior-use Certificate of FMEDA data
•
—
★
QT(20)(21) (28)
Safety certified to IEC 61508 with certificate of FMEDA data
•
—
★
Product certifications
E1
ATEX Flameproof
•
•
★
I1
ATEX Intrinsic Safety
•
•
★
IA
ATEX FISCO Intrinsic Safety; for FOUNDATION fieldbus protocol only
•
—
★
N1
ATEX Type n
•
•
★
ND
ATEX Dust
•
•
★
38
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 4. Rosemount 3051SFA Annubar Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
K1
ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E1, I1, N1, and ND)
•
•
★
E4
TIIS Flameproof
•
•
★
E5
FM Explosion-proof, Dust Ignition-proof
•
•
★
I5
FM Intrinsically Safe; Nonincendive
•
•
★
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of E5
and I5)
•
•
★
E6(19)
CSA Explosion-proof, Dust Ignition-proof, Division 2
•
•
★
I6
CSA Intrinsically Safe
•
•
★
K6(19)
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of
E6 and I6)
•
•
★
E7
IECEx Flameproof, Dust Ignition-proof
•
•
★
I7
IECEx Intrinsic Safety
•
•
★
K7
IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, Type n (combination of E7, I7,
and N7)
•
•
★
E3
China Flameproof
•
•
★
EM
Technical Regulations Customs Union (EAC) Flameproof
•
•
★
IM
Technical Regulations Customs Union (EAC) Intrinsic Safety
•
•
★
KM
Technical Regulations Customs Union (EAC) Flameproof, Intrinsic Safety
•
•
★
KC
FM and ATEX Explosion-proof, Intrinsically Safe, Division 2 (combination of E5, E1, I5,
and I1)
•
•
KD(19)
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe (combination of E5, I5, E6, I6, E1,
and I1)
•
•
Shipboard approvals
D
1-7
SBS
American Bureau of Shipping
•
•
★
SBV
Bureau Veritas (BV) Type Approval
•
•
★
SDN
Det Norske Veritas (DNV) Type Approval
•
•
★
SLL
Lloyds Register (LR) Type Approval
•
•
★
Sensor fill fluid and O-ring options
L1
Inert Sensor Fill Fluid
•
•
★
L2
Graphite-Filled (PTFE) O-ring
•
•
★
LA
Inert Sensor Fill Fluid and Graphite-Filled (PTFE) O-ring
•
•
★
•
•
★
•
—
★
Digital display(20)
M5
PlantWeb LCD display (requires PlantWeb housing)
M7(21)(22)(23) Remote mount LCD display and interface, PlantWeb housing, no cable; SST bracket
M8(21)(22)
Remote mount LCD display and interface, PlantWeb housing, 50 ft. (15 m) cable; SST
bracket
•
—
★
M9(21)(22)
Remote mount LCD display and interface, PlantWeb housing, 100 ft. (31 m) cable; SST
bracket
•
—
★
www.rosemount.com
39
Rosemount 3051S Series
October 2014
Table 4. Rosemount 3051SFA Annubar Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Transient protection
D
1-7
T1(24)
•
•
★
Transient terminal block
Manifold for remote mount option
F2
3-Valve Manifold, Stainless Steel
•
•
★
F6
5-Valve Manifold, Stainless Steel
•
•
★
F1
3-Valve Manifold, Carbon Steel
•
•
F3
3-Valve Manifold, Alloy C-276
•
•
F5
5-Valve Manifold, Carbon Steel
•
•
F7
5-Valve Manifold, Alloy C-276
•
•
•
—
★
PlantWeb control functionality
A01
FOUNDATION fieldbus Advanced Control Function Block Suite
PlantWeb diagnostic functionality
D01
FOUNDATION fieldbus Diagnostics Suite
•
—
★
DA2(25)
Advanced HART Diagnostic Suite
•
—
★
•
—
★
—
•
★
PlantWeb enhanced measurement functionality
H01(26)
FOUNDATION fieldbus Fully Compensated Mass Flow Block
Cold temperature
BRR (27)
-60 °F (-51 °C) Cold Temperature Start-up
Alarm limit(21)(28)
C4
NAMUR Alarm & Saturation Levels, High Alarm
•
•
★
C5
NAMUR Alarm & Saturation Levels, Low Alarm
•
•
★
C6
Custom Alarm & Saturation Levels, High Alarm
•
•
★
C7
Custom Alarm & Saturation Levels, Low Alarm
•
•
★
C8
Low Alarm (Standard Rosemount Alarm & Saturation Levels)
•
•
★
D1(21)(28) (29) Hardware Adjustments (zero, span, alarm, security)
•
—
★
D4(30)
External Ground Screw Assembly
•
•
★
DA(21) (29) (29)
Hardware Adjustments (zero, span, alarm, security) & External Ground Screw Assembly
•
—
★
316 SST Conduit Plug
•
•
★
Hardware adjustments and ground screw
Conduit plug
DO
40
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 4. Rosemount 3051SFA Annubar Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Conduit electrical connector
D
1-7
GE (31)
M12, 4-pin, Male Connector (eurofast)
•
•
★
A size Mini, 4-pin, Male Connector (minifast)
•
•
★
GM
(31)
Typical model number:
3051SFA D L 060 D
C
H
P
S
2
T1
0
0
0
3
2A
A
1A
3
(1) Provide the “A” dimension for Flanged, Flange-Lok, and Threaded Flo-Tap models. Provide the “B” dimension for Flange Flo-Tap models.
(2) Available in remote mount applications only.
(3) The cage nipple is constructed of 304SST.
(4) Temperature Measurement Option code T or R is required for Measurement Type codes 1, 3, 5, and 7.
(5) Required for Measurement Type codes 2, 4, 6, and D.
(6) Required for Measurement Type codes 3, 4, 7, and D.
(7) For Measurement Type codes 1, 2, 5, and 6 with DP range 1, absolute limits are 0.5 to 2000 psi (0,03 to 137,9 bar) and gage limits are
-14.2 to 2000 psig (-0,98 to 137,9 bar).
(8) Only intrinsically safe approval codes apply.
(9) Only available with Measurement Types D and 6.
(10) Only available with output code X.
(11) Only available with output code A.
(12) For detailed specifications see “Specifications” on page 107.
(13) Only available with differential pressure ranges 2 and 3, and silicone fill fluid.
(14) Long-life Power Module must be shipped separately, order Power Module 701PBKKF.
(15) Applies to assembled flowmeter only, mounting not tested.
(16) Instrument Connections for Remote Mount Options and Isolation Valves for Flo-tap Models are not included in the Material Traceability Certification.
(17) Not available with Transmitter Connection Platform 6.
(18) Materials of Construction comply with metallurgical requirements within NACE MR0175/ISO 15156 for sour oil field production environments. Environmental
limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
(19) Not available with M20 or G ½ conduit entry size.
(20) Not available with housing code 7J.
(21) Not available with output code X.Only available with Measurement Type D.
(22) Not available with output code F, option code DA2, or option code QT.
(23) See the 3051S Reference Manual (document number 00809-0100-4801) for cable requirements. Contact an Emerson Process Management representative for
additional information.
(24) Not available with Housing code 5A, 5J, or 7J. External ground screw assembly (option code D4) is included with the T1 option. The T1 option is not needed with
FISCO Product Certifications.
(25) Includes Hardware Adjustments (option code D1) as standard. Not available with output code X. Only available with Measurement Type D.
www.rosemount.com
41
Rosemount 3051S Series
October 2014
(26) Requires Rosemount Engineering Assistant version 5.5.1 to configure.
(27) -58°F (50°C) for Measurement Type 1-7.
(28) Not available with output code F.
(29) Not available with housing codes 2E, 2F, 2G, 2M, 5A, 5J, or 7J.
(30) This assembly is included with options EP, KP, E1, N1, K1, ND, E4, E7, N7, K7, E2, E3, KA, KC, KD, IA, IE, N3, T1, EM, and KM.
(31) Not available with Housing code 5A, 5J, or 7J. Available with intrinsically Safe approvals only. For FM intrinsically Safe; Nonincendive (option code I5) or FM FISCO
Intrinsically Safe (option code IE), install in accordance with Rosemount drawing 03151-1009.
42
www.rosemount.com
October 2014
Rosemount 3051S Series
Rosemount 3051SFC Compact Flowmeter

Compact conditioning flowmeters reduce straight piping requirements to 2D upstream and 2D downstream
from most flow disturbances

Simple installation of compact flowmeters between any existing raised-face flanges
Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See
page 127 for more information on Material Selection.
Table 5. Rosemount 3051SFC Compact Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model
3051SFC
Product description
Compact Orifice Flowmeter
Measurement
type
D
1-7
•
•
• = Available
— = Unavailable
Measurement type
1
Fully Compensated Mass & Energy Flow Calculations – Differential & Static Pressures
w/ Temperature
—
•
★
2
Compensated Flow Calculations – Differential & Static Pressures
—
•
★
3
Compensated Flow Calculations – Differential Pressure & Temperature
—
•
★
4
Compensated Flow Calculations – Differential Pressure
—
•
★
D
Differential Pressure
•
—
★
5
Process Variables Only (No Flow Calculations) – Differential & Static Pressures w/
Temperature
—
•
6
Process Variables Only (No Flow Calculations) – Differential & Static Pressures
—
•
7
Process Variables Only (No Flow Calculations) – Differential Pressure & Temperature
—
•
Primary element technology
A
Annubar Averaging Pitot Tube
•
•
★
C
Conditioning Orifice Plate
•
•
★
P
Orifice Plate
•
•
★
316 SST
•
•
★
005(1)
1/2-in. (15 mm)
•
•
★
010(1)
1-in. (25 mm)
•
•
★
11/2-in. (40 mm)
•
•
★
020
2-in. (50 mm)
•
•
★
030
3-in. (80 mm)
•
•
★
040
4-in. (100 mm)
•
•
★
060
6-in. (150 mm)
•
•
★
080
8-in. (200 mm)
•
•
★
Material type
S
Line size
015
(1)
www.rosemount.com
43
Rosemount 3051S Series
October 2014
Table 5. Rosemount 3051SFC Compact Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
100(2)(3)
10-in. (250 mm)
•
•
★
(2)(3)
12-in. (300 mm)
•
•
★
Primary element type
D
1-7
N000
Annubar Sensor Size 1
•
•
★
N040
0.40 Beta Ratio (β)
•
•
★
N050
0.50 Beta Ratio (β)
•
•
★
0.65 Beta Ratio (β)
•
•
★
120
(4)
N065
Temperature measurement
T(6)
Integral RTD
—
•
★
0(5)
No Temperature Sensor
•
•
★
R(6)
Remote Thermowell and RTD
•
•
Transmitter connection platform
3
Direct-mount
•
•
★
7
Remote-mount, NPT Connections
•
•
★
Differential pressure range
1
0 to 25 inH2O (0 to 62,16 mbar)
•
•
★
2
0 to 250 inH2O (0 to 621,60 mbar)
•
•
★
3
0 to 1000 inH2O (0 to 2,48 bar)
•
•
★
Static pressure range
A(7)
None
•
•
★
D
Absolute 0 to 800 psia (0 to 55,15 bar)
—
•
★
E(8)
Absolute 0 to 3626 psia (0 to 250,00 bar)
—
•
★
J
Gage -14.2 to 800 psig (-0,98 to 55,15 bar)
—
•
★
K(8)
Gage -14.2 to 3626 psig (-0,98 to 250,00 bar)
—
•
★
Transmitter output
A
4–20 mA with digital signal based on HART protocol
•
•
★
F(9)
FOUNDATION fieldbus protocol
•
—
★
X(10)(11)
Wireless
•
—
★
•
—
★
Transmitter housing style
Material
Conduit
entry size
00
None (Customer-supplied electrical connection)
1A
PlantWeb housing
Aluminum
1
/2-14 NPT
•
•
★
1B
PlantWeb housing
Aluminum
M20 x 1.5
•
•
★
•
•
★
•
•
★
1J
PlantWeb housing
SST
1/2-14 NPT
1K
PlantWeb housing
SST
M20 x 1.5
44
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 5. Rosemount 3051SFC Compact Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
2A
Junction Box housing
Aluminum
1
/2-14 NPT
•
—
★
2B
Junction Box housing
Aluminum
M20 x 1.5
•
—
★
2E
Junction Box housing with output for remote display and
interface
Aluminum
1
/2-14 NPT
•
—
★
2F
Junction Box housing with output for remote display and
interface
Aluminum
M20 x 1.5
•
—
★
2J
Junction Box housing
SST
1
•
—
★
2M
Junction Box housing with output for remote display and
interface
SST
1
•
—
★
5A(12)
Wireless PlantWeb housing
Aluminum
1
•
—
★
SST
1
•
—
★
•
—
★
5J(12)
Wireless PlantWeb housing
7J(10)(13)
Quick Connect (A size Mini, 4-pin male termination)
1C
PlantWeb housing
/2-14 NPT
/2-14 NPT
/2-14 NPT
/2-14 NPT
Aluminum
G1/2
•
•
SST
G1/2
•
•
•
—
•
—
Performance class(14)
D
1-7
3051S MultiVariable SuperModule, Measurement Types 1, 2, 5, and 6
•
•
1L
PlantWeb housing
2C
Junction Box housing
Aluminum
G1/2
2G
Junction Box housing with output for remote display and
interface
Aluminum
G1/2
3(15)
Ultra for Flow: 0.75% flow rate accuracy, 14:1 flow turndown, 10-yr stability, 15-yr
limited warranty
•
•
★
5
Classic MV: 1.10% flow rate accuracy, 8:1 flow turndown, 5-yr stability
—
•
★
3051S Single Variable SuperModule, Measurement Types 3, 4, 7, and D
1
Ultra: 0.90% flow rate accuracy, 8:1 flow turndown, 15-yr stability, 15-yr limited
warranty
•
—
★
2
Classic: 1.40% flow rate accuracy, 8:1 flow turndown, 15-yr stability
•
—
★
3(15)
Ultra for Flow: 0.75% flow rate accuracy, 14:1 flow turndown, 15-yr stability, 15-yr
limited warranty
•
•
★
•
—
★
•
—
★
Wireless options (requires option code X and wireless PlantWeb housing)
Update rate, operating frequency, and protocol
WA
User Configurable Update Rate
Operating frequency and protocol
3
2.4 GHz DSSS, IEC 62591 (WirelessHART)
Omni-directional wireless antenna
WK
External Antenna
•
—
★
WM
Extended Range, External Antenna
•
—
★
WN
High-Gain, Remote Antenna
•
—
www.rosemount.com
45
Rosemount 3051S Series
October 2014
Table 5. Rosemount 3051SFC Compact Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
SmartPower
1(16)
Adapter for Black Power Module (I.S. Power Module Sold Separately)
D
1-7
•
—
★
Other options (include with selected model number)
Extended product warranty
WR3
3-year limited warranty
•
•
★
WR5
5-year limited warranty
•
•
★
Installation accessories
A
ANSI Alignment Ring (150#) (Only required for 10-in. [250 mm] and 12-in. [300mm]
line sizes)
•
•
★
C
ANSI Alignment Ring (300#) (Only required for 10-in. [250 mm] and 12-in. [300mm]
line sizes)
•
•
★
D
ANSI Alignment Ring (600#) (Only required for 10-in. [250 mm] and 12-in. [300mm]
line sizes)
•
•
★
G
DIN Alignment Ring (PN 16)
•
•
★
H
DIN Alignment Ring (PN 40)
•
•
★
J
DIN Alignment Ring (PN 100)
•
•
★
B
JIS Alignment Ring (10K)
•
•
R
JIS Alignment Ring (20K)
•
•
S
JIS Alignment Ring (40K)
•
•
•
•
•
•
Remote adapters
E
Flange adapters 316 SST (1/2-in. NPT)
★
High temperature applications
T
Graphite Valve Packing (Tmax = 850 °F)
Flow calibration
WC(17)
Flow Calibration, 3 Pt, Conditioning Option C (All Pipe Schedules)
•
•
WD(18)(19)
Flow Calibration, 10 Pt, Conditioning Option C (All Schedules), Annubar Option A
(Schedule 40)
•
•
•
•
Pressure testing
P1
Hydrostatic Testing with Certificate
Special cleaning
P2(20)
Cleaning for Special Processes
•
•
PA
Cleaning per ASTM G93 Level D (section 11.4)
•
•
Special inspection
QC1
Visual & Dimensional Inspection with Certificate
•
•
★
QC7
Inspection & Performance Certificate
•
•
★
46
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 5. Rosemount 3051SFC Compact Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Transmitter calibration certification
D
1-7
Q4
Calibration Data Certificate for Transmitter
•
•
★
QP
Calibration Certificate and Tamper Evident Seal
•
•
★
Prior-use certificate of FMEDA data
•
—
★
Safety Certified to IEC 61508 with certificate of FMEDA data
•
—
★
•
•
★
Quality certification for safety
QS(21)(22)
QT
(21)(22)(25)
Material traceability certifications
Q8
Material Traceability Certification per EN 10204:2004 3.1
Code conformance
J2
ANSI / ASME B31.1
•
•
J3
ANSI / ASME B31.3
•
•
J4
ANSI / ASME B31.8
•
•
•
•
•
•
Material conformance
J5(23)
NACE MR-0175 / ISO 15156
Country certification
J1
Canadian Registration
Product certifications
E1
ATEX Flameproof
•
•
★
I1
ATEX Intrinsic Safety
•
•
★
IA
ATEX FISCO Intrinsic Safety; for FOUNDATION fieldbus protocol only
•
—
★
N1
ATEX Type n
•
•
★
ND
ATEX Dust
•
•
★
K1
ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E1, I1, N1, and ND)
•
•
★
E4
TIIS Flameproof
•
•
★
E5
FM Explosion-proof, Dust Ignition-proof
•
•
★
I5
FM Intrinsically Safe; Nonincendive
•
•
★
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination
of E5 and I5)
•
•
★
E6(24)
CSA Explosion-proof, Dust Ignition-proof, Division 2
•
•
★
I6
CSA Intrinsically Safe
•
•
★
K6(24)
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination
of E6 and I6)
•
•
★
E7
IECEx Flameproof, Dust Ignition-proof
•
•
★
I7
IECEx Intrinsic Safety
•
•
★
www.rosemount.com
47
Rosemount 3051S Series
October 2014
Table 5. Rosemount 3051SFC Compact Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
K7
IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, Type n (combination of E7,
I7, and N7)
•
•
★
E3
China Flameproof
•
•
★
I3
China Intrinsic Safety
•
•
★
EM
Technical Regulations Customs Union (EAC) Flameproof
•
•
★
IM
Technical Regulations Customs Union (EAC) Intrinsic Safety
•
•
★
KM
Technical Regulations Customs Union (EAC) Flameproof, Intrinsic Safety
•
•
★
KA(24)
ATEX and CSA Flameproof, Intrinsically Safe, Division 2 (combination of E1, I1, E6,
and I6)
•
•
★
KB(24)
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
(combination of E5, E6, I5, and I6)
•
•
★
KC
FM and ATEX Explosion-proof, Intrinsically Safe, Division 2 (combination of E5, E1, I5,
and I1)
•
•
★
KD(24)
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe (combination of E5, E6, E1, I5,
I6, and I1)
•
•
★
Shipboard approvals
D
1-7
SBS
American Bureau of Shipping
•
•
★
SBV
Bureau Veritas (BV) Type Approval
•
•
★
SDN
Det Norske Veritas (DNV) Type Approval
•
•
★
SLL
Lloyds Register (LR) Type Approval
•
•
★
Sensor fill fluid and O-ring options
L1
Inert Sensor Fill Fluid
•
•
★
L2
Graphite-filled (PTFE) O-ring
•
•
★
LA
Inert sensor fill fluid and graphite-filled (PTFE) O-ring
•
•
★
Digital display(25)
M5
PlantWeb LCD display
•
•
★
M7(22)(26)(27)
Remote mount LCD display and interface, PlantWeb housing, no cable, SST bracket
•
—
★
M8(22)(26)
Remote mount LCD display and interface, PlantWeb housing, 50 ft. (15m) cable, SST
bracket
•
—
★
M9(22)(26)
Remote mount LCD display and interface, PlantWeb housing, 100 ft. (31m) cable,
SST bracket
•
—
★
•
•
★
Transient protection
T1(28)
Transient terminal block
Manifold for remote mount option
F2
3-Valve Manifold, SST
•
•
★
F6
5-Valve Manifold, SST
•
•
★
48
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 5. Rosemount 3051SFC Compact Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
PlantWeb control functionality
D
1-7
A01
•
—
★
FOUNDATION fieldbus Advanced Control Function Block Suite
PlantWeb diagnostic functionality
D01
FOUNDATION fieldbus Diagnostics Suite
•
—
★
DA2(29)
Advanced HART Diagnostic Suite
•
—
★
•
—
★
•
•
★
PlantWeb enhanced measurement functionality
H01(30)
FOUNDATION fieldbus Fully Compensated Mass Flow Block
Cold temperature
BRR (31)(32)
-60 °F (-51 °C) Cold Temperature Start-up
Alarm limit(21)(22)
C4
NAMUR Alarm & Saturation Levels, High Alarm
•
•
★
C5
NAMUR Alarm & Saturation Levels, Low Alarm
•
•
★
C6
Custom Alarm & Saturation Levels, High Alarm
•
•
★
C7
Custom Alarm & Saturation Levels, Low Alarm
•
•
★
C8
Low Alarm (Standard Rosemount Alarm & Saturation Levels)
•
•
★
Hardware adjustments and ground screw
D1(21)(22)(32)
Hardware adjustments (zero, span, alarm, security).
•
—
★
D4(33)
External ground screw assembly
•
•
★
DA(21)(22)(32)
Hardware adjustments (zero, span, alarm, security) and external ground screw
assembly
•
—
★
316 SST Conduit Plug
•
•
★
Conduit plug
DO
Conduit electrical connector
ZE(34)
M12, 4-pin, Male Connector (eurofast)
•
•
★
ZM (34)
A size Mini, 4-pin, Male Connector (minifast)
•
•
★
Typical model number:
3051SFC 1 C S 060 N 065 T 3 2 J A 1A 3
(1) Available with primary element technology P only.
(2) For the 10-in. (250 mm) and 12-in. (300 mm) line sizes, the alignment ring must be ordered (Installation Accessories).
(3) 10-in. (250 mm) and 12-in. (300 mm) line sizes not available with Primary Element Technology code A.
(4) For 2-in. (50 mm) line size the beta ratio is 0.6 for Primary Element Technology code C.
(5) Required for Measurement Type codes 2, 4, 6, and D.
(6) Only available with Measurement Type codes 1, 3, 5, 7.
www.rosemount.com
49
Rosemount 3051S Series
October 2014
(7) Required for Measurement Type codes 3, 4, 7, and D.
(8) For Measurement Type codes 1, 2, 5, and 6 with DP range 1, absolute limits are 0.5 to 2000 psi (0,03 to 137,9 bar) and gage limits are
-14.2 to 2000 psig (-0,98 to 137,9 bar).
(9) Requires PlantWeb housing.
(10) Only intrinsically safe approval codes apply.
(11) Only available with Measurement Types D and 6.
(12) Only available with output code X.
(13) Available with output code A only.
(14) For detailed specifications see “Specifications” on page 107.
(15) Only available with differential pressure ranges 2 and 3, and silicone fill fluid.
(16) Long-life Power Module must be shipped separately, order Power Module 701PBKKF.
(17) Available with Primary Element Technology code C only.
(18) Available with Primary Element Technology codes C or A only.
(19) For Annubar Option A, consult factory for pipe schedules other than Sch. 40.
(20) Available with primary element technology C or P only.
(21) Not available with Output Protocol code F.
(22) Not available with output code X. Only available with Measurement Type D.
(23) Materials of Construction comply with metallurgical requirements within NACE MR0175/ISO for sour oil field production environments. Environmental limits
apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
(24) Not available with M20 or G½ conduit entry size.
(25) Not available with housing code 7J.
(26) Not available with output code F, option code DA2, or option code QT.
(27) See the 3051S Reference Manual (document number 00809-0100-4801) for cable requirements. Contact an Emerson Process Management representative for
additional information.
(28) Not available with Housing code 00, 5A, 5J, or 7J. External ground screw assembly (option code D4) is included with the T1 option. The T1 option is not needed
with FISCO Product Certifications.
(29) Includes Hardware Adjustments (option code D1) as standard. Not available with output code X. Only available with Measurement Type D.
(30) Requires Rosemount Engineering Assistant version 5.5.1 to configure.
(31) -58°F (50°C) for Measurement Type 1-7.
(32) Not available with housing codes 2E, 2F, 2G, 2M, 5A, 5J, or 7J.
(33) This assembly is included with options EP, KP, E1, N1, K1, ND, E4, E7, K7, E3, KA, KC, KD, IA, T1, EM, and KM.
(34) Not available with Housing code 5A, 5J, or 7J. Available with Intrinsically Safe approvals only. For FM Intrinsically Safe; Nonincendive (option code I5) or FM FISCO
Intrinsically Safe (option code IE), install in accordance with Rosemount drawing 03151-1009.
50
www.rosemount.com
October 2014
Rosemount 3051S Series
Rosemount 3051SFP Integral Orifice Flowmeter

Precision honed pipe section for increased accuracy in small line sizes

Self-centering plate design prevents alignment errors that magnify measurement inaccuracies in small line
sizes
Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See
page 127 for more information on Material Selection.
Table 6. Rosemount 3051SFP Integral Orifice Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model
3051SFP
Product description
Integral Orifice Flowmeter
Measurement
type
D
1-7
•
•
• = Available
— = Unavailable
Measurement type
1
Fully Compensated Mass & Energy Flow Calculations – Differential & Static Pressures w/
Temperature
—
•
★
2
Compensated Flow Calculations – Differential & Static Pressures
—
•
★
3
Compensated Flow Calculations – Differential Pressure & Temperature
—
•
★
4
Compensated Flow Calculations – Differential Pressure
—
•
★
D
Differential Pressure
•
—
★
5
Process Variables Only (No Flow Calculations) – Differential & Static Pressures w/
Temperature
—
•
6
Process Variables Only (No Flow Calculations) – Differential & Static Pressures
—
•
7
Process Variables Only (No Flow Calculations) – Differential Pressure & Temperature
—
•
316 SST
•
•
★
005
1
•
•
★
010
1-in. (25 mm)
•
•
★
•
•
★
NPT Female Body (not available with Thermowell and RTD)
•
•
★
S1
Socket Weld Body (not available with Thermowell and RTD)
•
•
★
P1
Pipe Ends: NPT threaded
•
•
★
P2
Pipe Ends: Beveled
•
•
★
D1
Pipe Ends: Flanged, DIN PN16, slip-on
•
•
★
D2
Pipe Ends: Flanged, DIN PN40, slip-on
•
•
★
D3
Pipe Ends: Flanged, DIN PN100, slip-on
•
•
★
W1
Pipe Ends: Flanged, ANSI Class 150, weld-neck
•
•
★
Body material
S
Line size
015
/2-in. (15 mm)
1
1 /2-in. (40 mm)
Process connection
T1
(1)
www.rosemount.com
51
Rosemount 3051S Series
October 2014
Table 6. Rosemount 3051SFP Integral Orifice Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
W3
Pipe Ends: Flanged, ANSI Class 300, weld-neck
•
•
★
W6
Pipe Ends: Flanged, ANSI Class 600, weld-neck
•
•
★
A1
Pipe Ends: Flanged, RF, ANSI Class 150, slip-on
•
•
A3
Pipe Ends: Flanged, RF, ANSI Class 300, slip-on
•
•
A6
Pipe Ends: Flanged, RF, ANSI Class 600, slip-on
•
•
R1
Pipe Ends: Flanged, RTJ, ANSI Class 150, slip-on
•
•
R3
Pipe Ends: Flanged, RTJ, ANSI Class 300, slip-on
•
•
R6
Pipe Ends: Flanged, RTJ, ANSI Class 600, slip-on
•
•
P9
Special Process Connection
•
•
Orifice plate material
D
1-7
S
316 SST
•
•
H
Alloy C-276
•
•
M
Alloy 400
•
•
★
Bore size option
0066
0.066-in. (1.68 mm) for 1/2-in. pipe
•
•
★
0109
0.109-in. (2.77 mm) for 1/2-in. pipe
•
•
★
0160
0.160-in. (4.06 mm) for 1/2-in. pipe
•
•
★
0196
0.196-in. (4.98 mm) for 1/2-in. pipe
•
•
★
0260
0.260-in. (6.60 mm) for 1/2-in. pipe
•
•
★
0340
0.340-in. (8.64 mm) for 1/2-in. pipe
•
•
★
0150
0.150-in. (3.81 mm) for 1-in. pipe
•
•
★
0250
0.250-in. (6.35 mm) for 1-in. pipe
•
•
★
0345
0.345-in. (8.76 mm) for 1-in. pipe
•
•
★
0500
0.500-in. (12.70 mm) for 1-in. pipe
•
•
★
0630
0.630-in. (16.00 mm) for 1-in. pipe
•
•
★
0800
0.800-in. (20.32 mm) for 1-in. pipe
0295
•
•
★
1
•
•
★
1
0.295-in. (7.49 mm) for 1 /2-in. pipe
0376
0.376-in. (9.55 mm) for 1 /2-in. pipe
•
•
★
0512
0.512-in. (13.00 mm) for 11/2-in. pipe
•
•
★
0748
0.748-in. (19.00 mm) for 11/2-in. pipe
1022
•
•
★
1
•
•
★
1
★
1.022-in. (25.96 mm) for 1 /2-in. pipe
1184
1.184-in. (30.07 mm) for 1 /2-in. pipe
•
•
0010
0.010-in. (0.25 mm) for 1/2-in. pipe
•
•
0014
0.014-in. (0.36 mm) for 1/2-in. pipe
•
•
1
0020
0.020-in. (0.51 mm) for /2-in. pipe
•
•
0034
0.034-in. (0.86 mm) for 1/2-in. pipe
•
•
52
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 6. Rosemount 3051SFP Integral Orifice Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Transmitter connection platform
D
1-7
D3
Direct-mount, 3-valve Manifold, SST
•
•
★
D5
Direct-mount, 5-valve Manifold, SST
•
•
★
R3
Remote-mount, 3-valve Manifold, SST
•
•
★
R5
Remote-mount, 5-valve Manifold, SST
•
•
★
D4
Direct-mount, 3-valve Manifold, Alloy C-276
•
•
D6
Direct-mount, 5-valve Manifold, Alloy C-276
•
•
D7
Direct-mount, High Temperature, 5-valve Manifold, SST
•
•
R4
Remote-mount, 3-valve Manifold, Alloy C-276
•
•
R6
Remote-mount, 5-valve Manifold, Alloy C-276
•
•
Differential pressure range
1
0 to 25 inH2O (0 to 62,16 mbar)
•
•
★
2
0 to 250 inH2O (0 to 621,60 mbar)
•
•
★
3
0 to 1000 inH2O (0 to 2,48 bar)
•
•
★
Static pressure range
A(2)
None
•
•
★
D
Absolute 0 to 800 psia (0 to 55,15 bar)
—
•
★
E(3)
Absolute 0 to 3626 psia (0 to 250,00 bar)
—
•
★
J
Gage -14.2 to 800 psig (-0,98 to 55,15 bar)
—
•
★
K(3)
Gage -14.2 to 3626 psig (-0,98 to 250,00 bar)
—
•
★
Transmitter output
A
4–20 mA with digital signal based on HART protocol
•
•
★
F
FOUNDATION fieldbus (Requires PlantWeb housing)
•
—
★
X(4)(5)
Wireless (Requires wireless options and wireless PlantWeb housing)
•
—
★
•
—
★
Transmitter housing style
Material
Conduit entry
size
00
None (Customer-supplied electrical connection)
1A
PlantWeb housing
Aluminum
1
/2-14 NPT
•
•
★
1B
PlantWeb housing
Aluminum
M20 x 1.5
•
•
★
•
•
★
1J
PlantWeb housing
SST
1/2-14 NPT
1K
PlantWeb housing
SST
M20 x 1.5
•
•
★
2A
Junction Box housing
Aluminum
1
/2-14 NPT
•
—
★
2B
Junction Box housing
Aluminum
M20 x 1.5
•
—
★
2E
Junction Box housing with output for remote
display and interface
Aluminum
1
•
—
★
www.rosemount.com
/2-14 NPT
53
Rosemount 3051S Series
October 2014
Table 6. Rosemount 3051SFP Integral Orifice Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
2F
Junction Box housing with output for remote
display and interface
Aluminum
M20 x 1.5
•
—
★
2J
Junction Box housing
SST
1
•
—
★
2M
Junction Box housing with output for remote
display and interface
SST
1
•
—
★
5A(6)
Wireless PlantWeb housing
Aluminum
1
•
—
★
(6)
5J
Wireless PlantWeb housing
SST
1
•
—
★
7J(4)(7)
Quick Connect (A size Mini, 4-pin male termination)
★
1C
PlantWeb housing
Aluminum
/2-14 NPT
/2-14 NPT
/2–14 NPT
/2–14 NPT
•
—
1
G /2
•
•
1
1L
PlantWeb housing
SST
G /2
•
•
2C
Junction Box housing
Aluminum
G1/2
•
—
2G
Junction Box housing with output for remote
display and interface
Aluminum
G1/2
•
—
D
1-7
Performance class(8)
3051S MultiVariable SuperModule, Measurement Types 1, 2, 5, and 6
3(9)
Ultra for Flow: 0.95% flow rate accuracy, 14:1 flow turndown, 10-year stability, 15-year
limited warranty
•
•
★
5
Classic MV: 1.25% flow rate accuracy, 8:1 flow turndown, 5-year stability
—
•
★
3051S Single Variable SuperModule, Measurement Types 3, 4, 7, and D
1
Ultra: 1.05% flow rate accuracy, 8:1 flow turndown, 15-year stability, 15-year limited
warranty
•
•
★
2
Classic: 1.50% flow rate accuracy, 8:1 flow turndown, 15-year stability
•
•
★
3(9)
Ultra for Flow: 0.95% flow rate accuracy, 14:1 flow turndown, 15-year stability, 15-year
limited warranty
•
•
★
•
—
★
•
—
★
Wireless options (requires option code X and wireless PlantWeb housing)
Update rate, operating frequency and protocol
WA
User Configurable Update Rate
Operating frequency and protocol
3
2.4 GHz DSSS, IEC 62591 (WirelessHART)
Omni-directional wireless antenna
WK
External Antenna
•
—
★
WM
Extended Range, External Antenna
•
—
★
WN
High-Gain, Remote Antenna
•
—
Adapter for Black Power Module (I.S. Power Module Sold Separately)
•
—
SmartPower
1(10)
54
★
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 6. Rosemount 3051SFP Integral Orifice Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Other options (include with selected model number)
Extended product warranty
D
1-7
WR3
3-year limited warranty
•
•
★
WR5
5-year limited warranty
•
•
★
•
•
•
•
★
•
•
★
•
•
Transmitter/body bolt material
G(11)
High temperature Option (850 °F [454 °C])
Temperature sensor
T(12)
Thermowell and RTD
Optional connection
G1
DIN 19213 Transmitter Connection
Pressure testing
P1(13)
Hydrostatic Testing with Certificate
Special cleaning
P2
Cleaning for Special Services
•
•
PA
Cleaning per ASTM G93 Level D (Section 11.4)
•
•
•
•
•
•
Material testing
V1
Dye Penetrant Exam
Material examination
V2
Radiographic Examination (available only with Process Connection code W1, W3, and
W6)
Flow calibration
WD(14)
Discharge Coefficient Verification
•
•
WZ(14)
Special Calibration
•
•
Special inspection
QC1
Visual & Dimensional Inspection with Certificate
•
•
★
QC7
Inspection & Performance Certificate
•
•
★
•
•
★
Material traceability certification
Q8
Material certification per EN 10204:2004 3.1
Code conformance
J2(15)
ANSI/ASME B31.1
•
•
J3(15)
ANSI/ASME B31.3
•
•
J4(15)
ANSI/ASME B31.8
•
•
www.rosemount.com
55
Rosemount 3051S Series
October 2014
Table 6. Rosemount 3051SFP Integral Orifice Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Materials conformance
J5(16)
NACE MR-0175 / ISO 15156
•
•
Country certification
★
J6
European Pressure Directive (PED)
•
•
J1
Canadian Registration
•
•
•
•
★
Transmitter calibration certification
Q4
Calibration Data Certificate for Transmitter
Quality certification for safety
QS(17)(18)
Prior-use Certificate of FMEDA data
•
—
★
QT(17)(18)(20)
Safety-certified to IEC 61508 with Certificate of FMEDA data
•
—
★
Product certifications
E1
ATEX Flameproof
•
•
★
I1
ATEX Intrinsic Safety
•
•
★
IA
ATEX FISCO Intrinsic Safety; for FOUNDATION fieldbus protocol only
•
—
★
N1
ATEX Type n
•
•
★
ND
ATEX Dust
•
•
★
K1
ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E1, I1, N1, and ND)
•
•
★
E4
TIIS Flameproof
•
•
★
E5
FM Explosion-proof, Dust Ignition-proof
•
•
★
I5
FM Intrinsically Safe; Nonincendive
•
•
★
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of
E5 and I5)
•
•
★
E6(19)
CSA Explosion-proof, Dust Ignition-proof, Division 2
•
•
★
I6
CSA Intrinsically Safe
•
•
★
K6(19)
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of
E6 and I6)
•
•
★
E7
IECEx Flameproof, Dust Ignition-proof
•
•
★
I7
IECEx Intrinsic Safety
•
•
★
K7
IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, Type n (combination of E7, I7,
and N7)
•
•
★
E3
China Flameproof
•
•
★
I3
China Intrinsic Safety
•
•
★
EM
Technical Regulations Customs Union (EAC) Flameproof
•
•
★
IM
Technical Regulations Customs Union (EAC) Intrinsic Safety
•
•
★
KM
Technical Regulations Customs Union (EAC) Flameproof, Intrinsic Safety
•
•
★
KA(19)
ATEX and CSA Flameproof, Intrinsically Safe, Division 2 (combination of E1, I1, E6, and
I6)
•
•
★
56
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 6. Rosemount 3051SFP Integral Orifice Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
KB(19)
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
(combination of E5, E6, I5, and I6)
•
•
★
KC
FM and ATEX Explosion-proof, Intrinsically Safe, Division 2 (combination of E5, E1, I5,
and I1)
•
•
★
KD(19)
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe (combination of E5, I5, E6, I6, E1,
and I1)
•
•
★
Shipboard approvals
D
1-7
SBS
American Bureau of Shipping
•
•
★
SBV
Bureau Veritas (BV) Type Approval
•
•
★
SDN
Det Norske Veritas (DNV) Type Approval
•
•
★
SLL
Lloyds Register (LR) Type Approval
•
•
★
Sensor fill fluid and O-ring options
L1
Inert Sensor Fill Fluid
•
•
★
L2
Graphite-filled (PTFE) O-ring
•
•
★
LA
Inert sensor fill fluid and graphite-filled (PTFE) O-ring
•
•
★
Digital display(20)
M5
PlantWeb LCD display (requires PlantWeb housing)
•
•
★
M7(17)(21)(22)
Remote mount LCD display and interface, PlantWeb housing, no cable, SST bracket
•
—
★
M8(17)(22)
Remote mount LCD display and interface, PlantWeb housing, 50 ft. (15 m) cable, SST
bracket
•
—
★
M9(17)(22)
Remote mount LCD display and interface, PlantWeb housing, 100 ft. (31 m) cable, SST
bracket
•
—
★
•
•
★
•
—
★
Transient protection
T1(23)
Transient terminal block
PlantWeb control functionality
A01
FOUNDATION fieldbus Advanced Control Function Block Suite
PlantWeb diagnostic functionality
D01
FOUNDATION fieldbus Diagnostics Suite
•
—
★
DA2(24)
Advanced HART Diagnostics Suite
•
—
★
•
—
★
—
•
★
PlantWeb enhanced measurement functionality
H01(25)
FOUNDATION fieldbus Fully Compensated Mass Flow Block
Cold temperature
BRR (26)
-60 °F (-51 °C) Cold Temperature Start-up
Alarm limit(17)(18)
C4
NAMUR Alarm & Saturation Levels, High Alarm
•
•
★
C5
NAMUR Alarm & Saturation Levels, Low Alarm
•
•
★
www.rosemount.com
57
Rosemount 3051S Series
October 2014
Table 6. Rosemount 3051SFP Integral Orifice Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
C6
Custom Alarm & Saturation Levels, High Alarm
•
•
★
C7
Custom Alarm & Saturation Levels, Low Alarm
•
•
★
C8
Low Alarm (Standard Rosemount Alarm & Saturation Levels)
•
•
★
Hardware adjustments and ground screw
D
1-7
D1(17)(18)(27)
Hardware Adjustments (zero, span, alarm, security)
•
—
★
External ground screw assembly
•
•
★
•
—
★
•
•
★
(28)
D4
DA(17)(18) (27) Hardware adjustments (zero, span, alarm, security) & External Ground Screw Assembly
Conduit plug
DO
316 SST Conduit Plug
Conduit electrical connector
GE (29)
M12, 4-pin, Male Connector (eurofast)
•
•
GM(29)
A size Mini, 4-pin, Male Connector (minifast)
•
•
Typical model number:
3051SFP 1 S 010 W3
S
0150
D3
1
J
A
1A
3
M5
(1) To improve pipe perpendicularity for gasket sealing, socket diameter is smaller than standard pipe O.D.
(2) Required for Measurement Type codes 3, 4, 7, and D.
(3) For Measurement Type codes 1, 2, 5, and 6 with DP range 1, absolute limits are 0.5 to 2000 psi (0,03 to 137,9 bar) and gage limits are
-14.2 to 2000 psig (-0,98 to 137,9 bar).
(4) Only intrinsically safe approval codes apply.
(5) Only available with Measurement Types D and 6.
(6) Only available with output code X.
(7) Only available with output code A.
(8) For detailed specifications see “Specifications” on page 107.
(9) Only available with differential pressure ranges 2 and 3, and silicone fill fluid.
(10) Long-life Power Module must be shipped separately, order Power Module 701PBKKF.
(11) Not available with 11/2-in. (38 mm) line size.
(12) Thermowell material is the same as the body material.
(13) Does not apply to Process Connection codes T1 and S1.
(14) Not available for bore sizes 0010, 0014, 0020, or 0034.
(15) Not available with DIN Process Connection codes D1, D2, or D3.
(16) Materials of Construction comply with metallurgical requirements within NACE MR0175/ISO for sour oil field production environments. Environmental limits apply
to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
(17) Not available with output code X. Only available with Measurement Type D.
(18) Not available with output code F.
58
www.rosemount.com
October 2014
Rosemount 3051S Series
(19) Not available with M20 or G ½ conduit entry size.
(20) Not available with housing code 7J.
(21) See the 3051S Reference Manual (document number 00809-0100-4801) for cable requirements. Contact an Emerson Process Management representative for
additional information.
(22) Not available with output code F, option code DA2, or option code QT.
(23) Not available with Housing code 5A, 5J, or 7J. The T1 option is not needed with FISCO Product Certifications.
(24) Includes Hardware Adjustments (option code D1) as standard. Not available with output code X. Only available with Measurement Type D.
(25) Requires Rosemount Engineering Assistant version 5.5.1 to configure.
(26) -58°F (50°C) for Measurement Type 1-7.
(27) Not available with housing codes 2E, 2F, 2G, 2M, 5A, 5J, or 7J.
(28) This assembly is included with options EP, KP, E1, N1, K1, ND, E4, E7, K7, E3, KA, KC, KD, IA, T1, EM, and KM.
(29) Not available with Housing code 5A, 5J, or 7J. Available with Intrinsically Safe approvals only. For FM Intrinsically Safe; Nonincendive (option code I5) or
FM FISCO Intrinsically Safe (option code IE), install in accordance with Rosemount drawing 03151-1009.
www.rosemount.com
59
Rosemount 3051S Series
October 2014
Rosemount 3051S Electronic Remote Sensor (ERS)
System
The 3051S ERS System is a flexible, 2-wire 4-20 mA HART architecture that
calculates differential pressure (DP) electronically using two pressure sensors
that are linked together with a non-proprietary electrical wire.
Ideal applications for the 3051S ERS System include tall vessels and distillation
columns that have traditionally required long lengths of capillary or impulse
piping. When used in these types of applications, the 3051S ERS System can
deliver:
1
Secondary
3051SAM
Primary
3

Faster time response

Simplified installations

Reduced maintenance
1. Choose two 3051S ERS Transmitter models. These may be any combination
of 3051SAM and 3051SAL models.
In-Line
3051SAL
Coplanar
More accurate and repeatable DP measurements
How to order
2
Coplanar

2. Decide which model will be the ERS Primary (4-20 mA loop termination and
optional LCD display) and which will be the ERS Secondary. This will be
specified by the “Configuration Type” code in each model number.
3. Specify two full model numbers per the desired configuration.
In-Line
3051SAL1PG4AA1A1020DFF71DA00M5
3051SAM1ST2A2E11A2A
Additional information
Specifications: page 107
Certifications: page 132
Dimensional drawings: page 145
Rosemount 3051SAM Transmitter for ERS Applications

Coplanar and in-line sensor module platforms

Variety of process connections including threaded NPT, flanges, manifolds, and 1199 remote seals

Available with 15-year stability and 15-year limited warranty
Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See
page 127 for more information on Material Selection.
Table 7. Rosemount 3051SAM Transmitter for ERS Applications Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model
Transmitter type
3051SAM
Scalable Advanced Measurement Transmitter
Performance class(1)
1
Ultra: 0.025% span accuracy, 200:1 rangedown, 15-year stability, 15-year limited warranty
★
2
Classic: 0.035% span accuracy, 150:1 rangedown, 15-year stability
★
60
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 7. Rosemount 3051SAM Transmitter for ERS Applications Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Configuration type
P
Electronic Remote Sensor - Primary
★
S
Electronic Remote Sensor - Secondary
★
Pressure module type
Pressure sensor type
G
Coplanar
Gage
★
T
In-Line
Gage
★
E
In-Line
Absolute
★
A
Coplanar
Absolute
Pressure range(2)
Coplanar gage
In-Line gage
In-Line absolute
Coplanar absolute
1A
N/A
-14.7 to 30 psig
(-1,01 to 2,06 bar)
0 to 30 psia
(0 to 2,06 bar)
0 to 30 psia
(0 to 2,06 bar)
★
2A
-250 to 250 inH2O
(-621,60 to 621,60 mbar)
-14.7 to 150 psig
(-1,01 to 10,34 bar)
0 to 150 psia
(0 to 10,34 bar)
0 to 150 psia
(0 to 10,34 bar)
★
3A
-393 to 1000 inH2O
(-0,97 to 2,48 bar)
-14.7 to 800 psig
(-1,01 to 55,15 bar)
0 to 800 psia
(0 to 55,15 bar)
0 to 800 psia
(0 to 55,15 bar)
★
4A
-14.2 to 300 psig
(-0,97 to 20,68 bar)
-14.7 to 4000 psig
(-1,01 to 275,79 bar)
0 to 4000 psia
(0 to 275,79 bar)
0 to 4000 psia
(0 to 275,79 bar)
★
5A
-14.2 to 2000 psig
(-0,97 to 137,89 bar)
-14.7 to 10000 psig
(-1,01 to 689,47 bar)
0 to 10000 psia
(0 to 689,47 bar)
N/A
★
Isolating diaphragm
2(3)
316L SST
★
3(3)
Alloy C-276
★
4(3)(4)
Alloy 400
(4)(5)
Tantalum
(3)(4)
6
Gold-plated Alloy 400 (includes Graphite-Filled PTFE O-Ring)
7(3)(4)
Gold-plated 316L SST
5
Process connection
Coplanar module type
In-Line module type
A11(6)
Assemble to Rosemount 305 Manifold
Assemble to Rosemount 306 Manifold
★
A12(6)
Assemble to Rosemount 304 or AMF Manifold with SST
Traditional Flange
Assemble AMF Manifold to ½-14 NPT Female
Process Connection
★
A15(6)
Assemble to Rosemount 304 or AMF manifold to SST
Traditional Flange with Alloy C-276 Drain Vents
N/A
★
A22(6)
Assemble AMF manifold to SST Coplanar Flange
N/A
★
www.rosemount.com
61
Rosemount 3051S Series
October 2014
Table 7. Rosemount 3051SAM Transmitter for ERS Applications Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
B11(6)(7)
Assemble to One Rosemount 1199 Remote Diaphragm
Seal with SST transmitter flange
Assemble to One Rosemount 1199 Remote
Diaphragm
★
E11
Coplanar Flange (CS), ¼-18 NPT, 316 SST Drain Vents
½ -14 NPT Female
★
E12
Coplanar Flange (SST), ¼-18 NPT, 316 SST Drain Vents
N/A
★
E13(3)
Coplanar Flange (Cast C-276), ¼-18 NPT, Alloy C-276
Drain Vents
N/A
★
E14
Coplanar Flange (Cast Alloy 400), ¼-18 NPT, Alloy
400/K-500 Drain Vents
N/A
★
E15(3)
Coplanar Flange (SST), ¼-18 NPT, Alloy C-276 Drain Vents
N/A
★
E16(3)
Coplanar Flange (CS), ¼-18 NPT, Alloy C-276 Drain Vents
N/A
★
E21
Coplanar Flange (CS), RC ¼, 316 SST Drain Vents
N/A
★
E22
Coplanar Flange (SST), RC ¼, 316 SST Drain Vents
N/A
★
E23(3)
Coplanar Flange (Cast C-276), RC ¼, Alloy C-276 Drain
Vents
N/A
★
E24
Coplanar Flange (Cast Alloy 400), RC ¼, Alloy 400/K-500
Drain Vents
N/A
★
E25(3)
Coplanar Flange (SST), RC ¼, Alloy C-276 Drain Vents
N/A
★
E26(3)
Coplanar Flange (CS), RC ¼, Alloy C-276 Drain Vents
N/A
★
F12
Traditional Flange (SST), 1/4-18 NPT, 316 SST Drain Vents
N/A
★
F13(3)
Traditional Flange (Cast C-276), 1/4-18 NPT, Alloy C-276
Drain Vents
N/A
★
F14
Traditional Flange (Cast Alloy 400), 1/4-18 NPT, Alloy
400/K-500 Drain Vents
N/A
★
F15(3)
Traditional Flange (SST), 1/4-18 NPT, Alloy C-276 Drain
Vents
N/A
★
F22
Traditional Flange (SST), RC ¼, 316 SST Drain Vents
N/A
★
F23(3)
Traditional Flange (Cast C-276), RC ¼, Alloy C-276 Drain
Vents
N/A
★
F24
Traditional Flange (Cast Alloy 400), RC ¼, Alloy 400/K500
Drain Vents
N/A
★
F25(3)
Traditional Flange (SST), RC ¼, Alloy C-276 Drain Vents
N/A
★
F52
DIN-Compliant Traditional Flange (SST), ¼-18 NPT, 316
Drain Vents, 7-16-in. Bolting
N/A
★
G11
Vertical Mount Level Flange (SST), 2-in ANSI Class 150, 316
SST Drain Vents
G1/2 A DIN 16288 male (Range 1-4 only)
★
G12
Vertical Mount Level Flange (SST), 2-in ANSI Class 300, 316
SST Drain Vents
N/A
★
G21
Vertical Mount Level Flange (SST), 3-in ANSI Class 150, 316
SST Drain Vents
N/A
★
G22
Vertical Mount Level Flange (SST), 3-in ANSI Class 300, 316
SST Drain Vents
N/A
★
62
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 7. Rosemount 3051SAM Transmitter for ERS Applications Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
G31
Vertical Mount Level Flange (SST), DIN-DN 50 PN 40, 316
SST Drain Vents
N/A
★
G41
Vertical Mount Level Flange (SST), DIN-DN 80 PN 40, 316
SST Drain Vents
N/A
★
F11
Traditional Flange (CS), ¼-18 NPT, 316 SST Drain / Vents
Non-Threaded Instrument Flange (I-Flange)
F32
Bottom Vent Traditional Flange (SST), ¼-18 NPT, 316 SST
Drain Vents
N/A
F42
Bottom Vent Traditional Flange (SST), RC ¼, 316 SST Drain
Vents
N/A
F62
DIN-Compliant Traditional Flange (316 SST), ¼-18 NPT,
316 Drain Vents, M10 Bolting
N/A
F72
DIN-Compliant Traditional Flange (316 SST), ¼-18 NPT,
316 Drain Vents, M12 Bolting
N/A
Transmitter output
A
★
4–20 mA with digital signal based on HART protocol
Housing style
Material
Conduit entry size
Housings for ERS Primary - Configuration Type code P
1A
PlantWeb housing
Aluminum
1/2–14 NPT
★
1B
PlantWeb housing
Aluminum
M20 x 1.5 (CM 20)
★
1J
PlantWeb housing
SST
1/2–14 NPT
★
1K
PlantWeb housing
SST
M20 x 1.5 (CM 20)
★
★
2E
Junction Box with Remote Display Output
Aluminum
1
2F
Junction Box with Remote Display Output
Aluminum
M20 x 1.5 (CM 20)
★
2M
Junction Box with Remote Display Output
SST
1/2–14 NPT
★
1C
PlantWeb housing
Aluminum
G1/2
1L
PlantWeb housing
SST
G1/2
2G
Junction Box with Remote Display Output
Aluminum
G1/2
/2–14 NPT
Housings for ERS Secondary - Configuration Type code S
2A
Junction Box
Aluminum
1/2–14 NPT
★
2B
Junction Box
Aluminum
M20 x 1.5 (CM 20)
★
★
2J
Junction Box
SST
1
2C
Junction Box
Aluminum
G1/2
/2–14 NPT
Options (include with selected model number)
Extended product warranty
WR3
3-year limited warranty
★
WR5
5-year limited warranty
★
www.rosemount.com
63
Rosemount 3051S Series
October 2014
Table 7. Rosemount 3051SAM Transmitter for ERS Applications Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Electronic remote sensor connection cable
R05
50 ft. (15.2 m) Spool of Electronic Remote Sensor Cable
★
R10
100 ft. (30.5 m) Spool of Electronic Remote Sensor Cable
★
R15
150 ft. (45.7 m) Spool of Electronic Remote Sensor Cable
★
Mounting bracket
B1(4)
Traditional flange bracket, CS, 2-in. pipe
★
Traditional flange bracket, CS, panel
★
B3(4)
Traditional flange flat bracket, CS, 2-in. pipe
★
B4
Bracket, all SST, 2-in. Pipe and Panel
★
B7(4)
Traditional flange bracket, B1 with SST bolts
★
B8(4)
Traditional flange bracket, B2 with SST bolts
★
B9(4)
Traditional flange bracket, B3 with SST bolts
★
BA(4)
Traditional flange bracket, B1, all SST
★
BC(4)
Traditional flange bracket, B3, all SST
★
B2
(4)
Special configuration (software)
C1(8)
Customer Software Configuration (Configuration Data Sheet must be completed)
★
C3
Gage Pressure Calibration on Rosemount 3051SAM_ _A4 only
★
C4(8)
NAMUR Alarm and Saturation Levels, High Alarm
★
C5(8)
NAMUR Alarm and Saturation Levels, Low Alarm
★
C6(8)
Custom Alarm and Saturation Levels, High Alarm (requires C1 and Configuration Data Sheet)
★
C7(8)
Custom Alarm and Saturation Levels, Low Alarm (requires C1 and Configuration Data Sheet)
★
C8(8)
Low alarm (standard Rosemount alarm and saturation levels)
★
Special configuration (hardware)
D2(9)
1/2-14 NPT Flange Adapters
★
D4(10)
External ground screw assembly
★
D5(9)
Delete transmitter drain/vent valves (install plugs)
★
D7(9)
Coplanar flange without drain/vent ports
D9(9)
RC 1/2 Flange Adapters
Product certifications
E1
ATEX Flameproof
★
I1
ATEX Intrinsic Safety
★
N1
ATEX Type n
★
K1
ATEX Flameproof and Intrinsically Safe, Type n, Dust
★
ND
ATEX Dust
★
64
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 7. Rosemount 3051SAM Transmitter for ERS Applications Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
E4
TIIS Flameproof
★
E5
FM Explosion-proof, Dust Ignition-proof
★
I5
FM Intrinsically Safe; Nonincendive
★
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
★
E6(11)
CSA Explosion-proof, Dust Ignition-proof, Division 2
★
I6
CSA Intrinsically Safe
★
K6(11)
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
★
E7
IECEx Flameproof
★
I7
IECEx Intrinsic Safety
★
N7
IECEx Type n
★
K7
IECEx Flameproof, Intrinsic Safety, Type n
★
E2
INMETRO Flameproof
★
I2
INMETRO Intrinsically Safe
★
K2
INMETRO Flameproof, Intrinsic Safety, Type n
★
E3
China Flameproof
★
I3
China Intrinsic Safety, Dust Ignition-proof
★
EP
Korea Flameproof
★
IP
Korea Intrinsic Safety
★
KP
Korea Flameproof, Intrinsic Safety
★
EM
Technical Regulations Customs Union (EAC) Flameproof
★
IM
Technical Regulations Customs Union (EAC) Intrinsic Safety
★
KM
Technical Regulations Customs Union (EAC) Flameproof, Intrinsic Safety
★
KA(11)
ATEX and CSA Flameproof, Intrinsically Safe, Division 2
★
KB(11)
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
★
KC
FM and ATEX Explosion-proof, Intrinsically Safe, Division 2
★
KD(11)
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe
★
Special certifications
Shipboard approvals
SBS
American Bureau of Shipping (ABS) Type Approval
★
SBV
Bureau Veritas (BV) Type Approval
★
SDN
Det Norske Veritas (DNV) Type Approval
★
SLL
Lloyds Register (LR) Type Approval
★
Calibration certification
Q4
Calibration certificate
★
QP
Calibration Certificate and Tamper Evident Seal
★
www.rosemount.com
65
Rosemount 3051S Series
October 2014
Table 7. Rosemount 3051SAM Transmitter for ERS Applications Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Material traceability certification
Q8
★
Material Traceability Certification per EN 10204 3.1
Quality certification for safety
QS
Prior-use certificate of FMEDA Data
★
QT
Safety Certified to IEC 61508 with certificate of FMEDA data
★
Surface finish certification
Q16(12)
★
Surface Finish Certification for Hygienic Remote Seals
Toolkit performance reports
QZ(13)
★
Remote Seal System Performance Calculation Report
Terminal blocks
T1(8)
★
Transient Terminal Block
Sensor fill fluid
L1(14)
Inert Sensor Fill Fluid
★
Graphite-Filled PTFE O-Ring
★
O-ring
L2
Bolting material
L4(9)
Austenitic 316 SST Bolts
★
L5(3)(9)
ASTM A 193, Grade B7M Bolts
★
L6(9)
Alloy K-500 Bolts
★
L7(3)(9)
ASTM A 453, Class D, Grade 660 Bolts
★
L8(9)
ASTM A 193, Class 2, Grade B8M Bolts
★
Display type (ERS primary only)
M5(8)
PlantWeb LCD display
★
M7(8)(15)
Remote Mount LCD display and Interface, PlantWeb housing, No Cable, SST Bracket
★
M8(8)
Remote Mount LCD display and Interface, PlantWeb housing, 50 ft. (15.2 m) Cable, SST Bracket
★
M9(8)
Remote Mount LCD display and Interface, PlantWeb housing, 100 ft. (30.5 m) Cable, SST Bracket
★
Special procedures
Pressure testing
P1
Hydrostatic Testing with Certificate
Special cleaning
P2(9)
Cleaning for Special Services
P3(9)
Cleaning for Less than 1 PPM Chlorine/Fluorine
66
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 7. Rosemount 3051SAM Transmitter for ERS Applications Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
NACE certificate
Q15(16)
Certificate of Compliance to NACE MR0175/ISO 15156 for wetted materials
★
Q25(16)
Certificate of Compliance to NACE MR0103 for wetted materials
★
Typical model number:
3051SAM 1 S T 2A 2 E11 A 2A
(1) For detailed specifications see “Specifications” on page 107.
(2) The pressure range should be specified based on the maximum static pressure, not differential pressure.
(3) Materials of Construction comply with metallurgical requirements highlighted within NACE MR 0175 / ISO 15156 for sour oil field production environments.
Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR 0103 for sour refining
environments. Order with Q15 or Q25 to receive a NACE certificate.
(4) Not available with Pressure Sensor/Module codes T or E.
(5) Tantalum diaphragm material is only available with Pressure Sensor / Module code G.
(6) “Assemble to” items are specified separately and require a completed model number.
(7) Consult an Emerson Process Management representative for performance specifications.
(8) Not available with Configuration Type code S.
(9) Not available with Process Connection code A11.
(10) This assembly is included with options EP, KP, E1, N1, K1, ND, E4, E7, N7, K7, E2, KA, KC, KD, K2, T1, E3, EM, and KM.
(11) Not available with M20 or G ½ conduit entry size.
(12) Q16 is only available when the diaphragm seal has surface finish options.
(13) The QZ report quantifies the performance of the entire ERS system. One report is provided per ERS system. The QZ option is specified on the Primary Transmitter
(Configuration Type code P).
(14) Silicone fill fluid is standard.
(15) See the 3051S Reference Manual (document number 00809-0100-4801) for cable requirements. Contact an Emerson Process Management representative for
additional information.
(16) NACE compliant wetted materials are identified by Footnote 3.
www.rosemount.com
67
Rosemount 3051S Series
October 2014
Rosemount 3051SAL Transmitter for ERS Applications

Integrated transmitter and direct mount seal in a single model number

Variety of process connections including flanged, threaded, and hygienic remote seals

Available with 15-year limited warranty
Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See
page 127 for more information on Material Selection.
A 3051SAL Scalable ERS Level Transmitter consists of 3 parts. First, specify the transmitter model codes found on page 68. Then,
specify a direct mount seal found on page 88. Finish the model number by specifying all desired options on page 71.
ERS Transmitter Model Codes__page 68
Direct Mount Seal Model Codes_page 88
ERS Options____page 71
Table 8. Rosemount 3051SAL Transmitter for ERS Applications Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model
Transmitter type
3051SAL
Scalable Advanced Level Transmitter
Performance class(1)
1
Ultra: 0.055% span accuracy, 150:1 rangedown, 15-year limited warranty
★
2
Classic: 0.065% span accuracy, 150:1 rangedown
★
Configuration type
P
Electronic Remote Sensor - Primary
★
S
Electronic Remote Sensor - Secondary
★
Pressure module type
Pressure sensor type
G
Coplanar
Gage
★
T
In-Line
Gage
★
E
In-Line
Absolute
★
A
Coplanar
Absolute
Pressure range(8)
Coplanar gage
In-Line gage
In-Line absolute
Coplanar
absolute
1A
N/A
-14.7 to 30 psig
(-1,01 to 2,06 bar)
0 to 30 psia
(0 to 2,06 bar)
0 to 30 psia
(0 to 2,06 bar)
★
2A
-250 to 250 inH2O
(-621,60 to 621,60 mbar)
-14.7 to 150 psig
(-1,01 to 10,34 bar)
0 to 150 psia
(0 to 10,34 bar)
0 to 150 psia
(0 to 10,34 bar)
★
3A
-393 to 1000 inH2O
(-0,97 to 2,48 bar)
-14.7 to 800 psig
(-1,01 to 55,15 bar)
0 to 800 psia
(0 to 55,15 bar)
0 to 800 psia
(0 to 55,15 bar)
★
68
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 8. Rosemount 3051SAL Transmitter for ERS Applications Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
4A
-14.2 to 300 psig
(-0,97 to 20,68 bar)
-14.7 to 4000 psig
(-1,01 to 275,79 bar)
0 to 4000 psia
(0 to 275,79 bar)
0 to 4000 psia
(0 to 275,79 bar)
★
5A
-14.2 to 2000 psig
(-0,97 to 137,89 bar)
-14.7 to 10000 psig
(-1,01 to 689,47 bar)
0 to 10000 psia
(0 to 689,47 bar)
N/A
★
Transmitter output
A
★
4-20 mA with Digital Signal Based on HART Protocol
Housing style
Material
Conduit entry size
Housings for ERS Primary - Configuration Type Code P
1A
PlantWeb housing
Aluminum
1
★
1B
PlantWeb housing
Aluminum
M20 x 1.5 (CM 20)
★
★
/2–14 NPT
1J
PlantWeb housing
SST
1
1K
PlantWeb housing
SST
M20 x 1.5 (CM 20)
★
2E
Junction Box with Remote Display
Output
Aluminum
1/2–14 NPT
★
2F
Junction Box with Remote Display
Output
Aluminum
M20 x 1.5 (CM 20)
★
2M
Junction Box with Remote Display
Output
SST
1/2–14 NPT
★
1C
PlantWeb housing
Aluminum
G1/2
1L
PlantWeb housing
SST
G1/2
2G
Junction Box with Remote Display
Output
Aluminum
G1/2
/2–14 NPT
Housings for ERS Secondary - Configuration Type Code S
2A
Junction Box
Aluminum
1/2–14 NPT
★
2B
Junction Box
Aluminum
M20 x 1.5 (CM 20)
★
SST
1
★
2J
2C
Junction Box
Junction Box
Aluminum
/2–14 NPT
1
G /2
Seal system type
Coplanar Pressure Module Type
1
Single Direct Mount Seal System
Welded-Repairable
★
2
Single Direct Mount Seal System
All-Welded
★
All-Welded
★
In-line Pressure Module Type
1
Single Direct Mount Seal System
High side connection type
Single Direct Mount Seal System (between transmitter and remote seal)
0
No Extension
★
2
2-in. (50 mm) Extension
★
www.rosemount.com
69
Rosemount 3051S Series
October 2014
Table 8. Rosemount 3051SAL Transmitter for ERS Applications Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
4
4-in. (100 mm) Extension
★
6
Thermal Range Expander - Silicone 200 Secondary Fill Fluid
★
7
Thermal Range Expander - SYLTHERM™ XLT Secondary Fill Fluid
★
Low side connection type (reference pressure connection)
Single Direct Mount Seal System
00
None (In-Line Pressure Module Type Only)
★
20
316L SST Isolator/SST Transmitter Flange
★
30
Alloy C-276 Isolator/SST Transmitter Flange
★
Temperature limits(2)
Seal fill fluid
Specific
gravity
at 77 °F No
(25 °C) extension
Thermal range
expander
2-in. (50 mm) 4-in. (100 mm)
(process
extension
extension
temperature)
(3)
D
Silicone 200
0.93
-49 to 401 °F
-49 to 401 °F
(-45 to 205 °C) (-45 to 205 °C)
F
Silicone 200 for Vacuum
Applications
0.93
For use in vacuum applications below 14.7 psia (1 bar-a), refer to vapor
pressure curves in Rosemount DP Level Fill Fluid Specification Technical
Note (00840-2100-4016).
★
L
Silicone 704
1.07
32 to 401 °F(4)
(0 to 205 °C)
★
C
Silicone 704 for Vacuum
Applications
1.07
For use in vacuum applications below 14.7 psia (1 bar-a), refer to vapor
pressure curves in Rosemount DP Level Fill Fluid Specification Technical
Note (00840-2100-4016).
★
R
Silicone 705
1.09
68 to 401 °F(4)
(20 to 205 °C)
★
V
Silicone 705 for Vacuum
Applications
1.09
For use in vacuum applications below 14.7 psia (1 bar-a), refer to vapor
pressure curves in Rosemount DP Level Fill Fluid Specification Technical
Note (00840-2100-4016).
★
A
SYLTHERM XLT
0.85
-102 to 293 °F -102 to 293 °F
(-75 to 145 °C) (-75 to 145 °C)
-102 to 293 °F
(-75 to 145 °C)
N/A
★
H
Inert (Halocarbon)
1.85
-49 to 320 °F
-49 to 320 °F
(-45 to 160 °C) (-45 to 160 °C)
-49 to 320 °F
(-45 to 160 °C)
N/A
★
G(5)(6)
Glycerin and Water
1.13
5 to 203 °F
(-15 to 95 °C)
5 to 203 °F
(-15 to 95 °C)
N/A
★
N(5)
Neobee® M-20
0.92
5 to 401 °F(4)
5 to 437 °F
(-15 to 205 °C) (-15 to 225 °C)
5 to 437 °F
(-15 to 225 °C)
N/A
★
P(5)(6)
Propylene Glycol and
Water
1.02
5 to 203 °F
(-15 to 95 °C)
5 to 203 °F
(-15 to 95 °C)
5 to 203 °F
(-15 to 95 °C)
N/A
★
Y(7)
UltraTherm™ 805
1.20
N/A
N/A
N/A
Up to 770 °F
(410 °C)
★
Z(7)
UltraTherm 805 for
Vacuum
1.20
For use in vacuum application below 14.7 psia (1 bar-a), refer to vapor
pressure curves in Rosemount DP Level Fill Fluid Specification Technical
Note (00840-2100-4016).
70
32 to 464 °F(4)
(0 to 240 °C)
68 to 464 °F(4)
(20 to 240 °C)
5 to 203 °F
(-15 to 95 °C)
-49 to 401 °F
(-45 to 205 °C)
32 to 500 °F(4)
(0 to 260 °C)
68 to 500 °F(4)
(20 to 260 °C)
N/A
Up to 599 °F
(315 °C)
Up to 698 °F
(370 °C)
★
★
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 8. Rosemount 3051SAL Transmitter for ERS Applications Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Continue specifying a completed model number by choosing a remote seal type below:
page 88
FF Flush Flanged Seal
Process Connections:
2-in. / DN 50 / 50A
3-in. / DN 80 / 80A
4 in. / DN 100 / 100A
EF Extended Flanged Seal
Process Connections:
3-in. / DN 80 / 80A
4-in. / DN 100 / 100A
page 93
RF Remote Flanged Seal
Process Connections:
½ -in.
¾ -in.
1-in. / DN 25 / 25A
1½-in. / DN 40 / 40A
page 98
FC Flush Flanged Seal - Ring Type Joint (RTJ)
Gasket Surface
2- in.
3 -in.
RC Ring Type Joint (RTJ) Flanged Seal
½-in.
¾-in.
1 -in.
1½- in.
RT Remote Threaded Seal
Process Connections:
¼ - 18 NPT
½ - 14 NPT
¾ - 14 NPT
1 - 11.5 NPT
1¼ - 11.5 NPT
page 104
SC Hygienic Tri-Clamp™ Seal
Process Connections:
1½-in.
2-in.
3-in.
page 105
SS Hygienic Tank Spud Seal
Process Connections:
4-in.
page 91
page 100
page 102
Options (include with selected model number)
Extended product warranty
WR3
3-year limited warranty
★
WR5
5-year limited warranty
★
Electronic remote sensor connection cable(8)
R05
50 ft. (15.2 m) Spool of Electronic Remote Sensor Cable
★
R10
100 ft. (30.5 m) Spool of Electronic Remote Sensor Cable
★
www.rosemount.com
71
Rosemount 3051S Series
October 2014
Table 8. Rosemount 3051SAL Transmitter for ERS Applications Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
R15
150 ft. (45.7 m) Spool of Electronic Remote Sensor Cable
★
Software configuration
C1(9)
Custom Software Configuration (requires Configuration Data Sheet)
★
Gage pressure calibration
C3
Gage Pressure Calibration on Rosemount 3051SAL_ _A4 only
★
Alarm limit
C4(9)
NAMUR Alarm and Saturation Levels, High Alarm
★
C5(9)
NAMUR Alarm and Saturation Levels, Low Alarm
★
C6
Custom Alarm and Saturation Levels, High Alarm (requires C1 and Configuration Data Sheet)
★
C7(9)
Custom Alarm and Saturation Levels, Low Alarm (requires C1 and Configuration Data Sheet)
★
C8(9)
Low Alarm (standard Rosemount alarm and saturation levels)
★
(9)
Ground screw
D4(10)
External Ground Screw Assembly
★
Conduit plug
DO
316 SST Conduit Plug
★
Product certifications
E1
ATEX Flameproof
★
I1
ATEX Intrinsic Safety
★
N1
ATEX Type n
★
K1
ATEX Flameproof and Intrinsically Safe, Type n, Dust
★
ND
ATEX Dust
★
E4
TIIS Flameproof
★
E5
FM Explosion-proof, Dust Ignition-proof
★
I5
FM Intrinsically Safe; Nonincendive
★
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
★
E6
CSA Explosion-proof, Dust Ignition-proof, Division 2
★
I6
CSA Intrinsically Safe
★
K6(11)
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
★
E7
IECEx Flameproof
★
I7
IECEx Intrinsic Safety
★
N7
IECEx Type n
★
K7
IECEx Flameproof, Intrinsic Safety, Type n
★
E2
INMETRO Flameproof
★
I2
INMETRO Intrinsically Safe
★
K2
INMETRO Flameproof, Intrinsic Safety
★
K5
(11)
72
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 8. Rosemount 3051SAL Transmitter for ERS Applications Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
EP
Korea Flameproof
★
E3
China Flameproof
★
I3
China Intrinsic Safety
★
IP
Korea Intrinsic Safety
★
KP
Korea Flameproof, Intrinsic Safety
★
EM
Technical Regulations Customs Union (EAC) Flameproof
★
IM
Technical Regulations Customs Union (EAC) Intrinsic Safety
★
Technical Regulations Customs Union (EAC) Flameproof, Intrinsic Safety
★
KM
(11)
ATEX and CSA Flameproof, Intrinsically Safe, Division 2
★
KB(11)
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
★
KC
FM and ATEX Explosion-proof, Intrinsically Safe, Division 2
★
KD(11)
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe
★
KA
Shipboard approvals
SBS
American Bureau of Shipping (ABS) Type Approval
★
SBV
Bureau Veritas (BV) Type Approval
★
SDN
Det Norske Veritas (DNV) Type Approval
★
SLL
Lloyds Register (LR) Type Approval
★
Sensor fill fluid
L1(12)
Inert Sensor Fill Fluid
★
Graphite-filled PTFE O-ring
★
O-ring
L2
Bolting material
L4
Austenitic 316 SST Bolts
★
L5
ASTM A 193, Grade B7M Bolts
★
L6
Alloy K-500 Bolts
★
L7(13)
ASTM A 453, Class D, Grade 660 Bolts
★
L8
ASTM A 193, Class 2, Grade B8M Bolts
★
Display type (ERS primary only)
M5(9)
PlantWeb LCD display
★
M7(9)(14)
Remote Mount LCD display and Interface, PlantWeb housing, No Cable, SST Bracket
★
M8(9)
Remote Mount LCD display and Interface, PlantWeb housing, 50 ft. (15.2 m) Cable, SST Bracket
★
M9(9)
Remote Mount LCD display and Interface, PlantWeb housing, 100 ft. (30.5 m) Cable, SST Bracket
★
www.rosemount.com
73
Rosemount 3051S Series
October 2014
Table 8. Rosemount 3051SAL Transmitter for ERS Applications Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Special procedures
Pressure testing
P1
Hydrostatic Testing with Certificate
Special cleaning
P2
Cleaning for Special Services
P3
Cleaning for Less than 1 PPM Chlorine/Fluorine
Special certifications
Calibration certification
Q4
Calibration Certificate
★
QP
Calibration certificate with tamper evident seal
★
Material traceability certification
Q8
★
Material traceability certification per EN 10204 3.1
Quality certification for safety
QS
Prior-use certificate of FMEDA Data
★
QT
Safety Certified to IEC 61508 with certificate of FMEDA data
★
Toolkit performance reports
QZ(15)
★
Remote Seal System Performance Calculation Report
Transient protection
T1(9)
★
Transient Terminal Block
NACE certificate
Q15(16)
Certificate of Compliance to NACE MR0175/ISO 15156 for wetted materials
★
Q25(16)
Certificate of Compliance to NACE MR0103 for wetted materials
★
Typical model number:
3051SAL 1 P G 4A A 1A 1 0 20 D FF 7 1 DA 0 0 M5
(1) For detailed specifications see “Specifications” on page 107.
(2) At ambient pressure of 14.7 psia (1 bar-a) and ambient temperature of 70 °F (21 °C). Temperature limits are reduced in vacuum service and may be limited by seal
selection.
(3)
For complete process and ambient temperature limits, see T “Thermal Range Expander temperature operating range” on page 126.
(4) Maximum process temperature is limited by heat transfer to the transmitter electronics and must be further derated if ambient temperature exceeds 70 °F (21 °C).
(5) This is a food grade fill fluid.
(6) Not suitable for vacuum applications.
74
www.rosemount.com
October 2014
Rosemount 3051S Series
(7) Only available with Thermal Range Expander.
(8) The pressure range should be specified based on the maximum static pressure, not differential pressure.
(9) Not available with Configuration Type code S.
(10) This assembly is included with options EP, KP, E1, N1, K1, ND, E4, E7, N7, K7, E2, KA, KC, KD, K2, T1, E3, EM, KM.
(11) Not available with M20 or G½ conduit entry size.
(12) Silicone fill fluid is standard.
(13) Bolts are not considered process wetted. In instances where NACE MR0175/ISO 15156 and NACE MR0103 conformance is required for bolting, L7 is the
recommended bolting option.
(14) See the 3051S Reference Manual (document number 00809-0100-4801) for cable requirements. Contact an Emerson Process Management representative for
additional information.
(15) The QZ report quantifies the performance of the entire ERS system. One report is provided per ERS system. The QZ option is specified on the Primary Transmitter
(Configuration Type code P).
(16) Materials of construction comply with metallurgical requirements highlighted within NACE MR 0175 / ISO 15156 for sour oil field production environments.
Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR 0103 for sour refining
environments.
www.rosemount.com
75
Rosemount 3051S Series
October 2014
Rosemount 3051S Scalable™ Level Transmitter
3051SAL In-Line with
“FF” Flanged Seal
Rosemount 3051S Scalable Level Transmitters combine the features and benefits of a
high-performance 3051S Pressure Transmitter with the durability and reliability of
diaphragm seals all in a single model number.
Product features and capabilities include:
3051SAL Coplanar with
“SS” Hygienic Tank Spud
Seal

Variety of process connections including flanged, threaded, and hygienic seals

Quantified performance for the entire transmitter/seal assembly (QZ option)

HART, FOUNDATION fieldbus, and Wireless protocols
3051SAL Tuned-System
Assembly with
Thermal Range
Expander
Additional information
Specifications: page 107
Product Certifications: page 132
Dimensional drawings: page 145
3051SAL Balanced
System
Rosemount 3051SAL Scalable Level Transmitter
Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See
page 127 for more information on Material Selection.
A 3051SAL Scalable Level Transmitter consists of 3 parts. First, specify the transmitter model codes found on page 76.
Then, specify a direct mount seal found on page 88. Finish the model number by specifying all desired options on page 83.
Transmitter Model Codes_....... page 76
Diaphragm Seal Model Codes_.page 88
Options_______ page 71
Table 9. Rosemount 3051SAL Scalable Level Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model
Transmitter type
3051SAL
Scalable Level Transmitter
Performance class(1)
1
Ultra: 0.055% span accuracy, 150:1 rangedown, 15-year limited warranty
★
2
Classic: 0.065% span accuracy, 150:1 rangedown
★
Configuration type
C
76
Liquid Level Transmitter
★
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 9. Rosemount 3051SAL Scalable Level Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Pressure module type
Pressure sensor type
D
Coplanar
Differential
★
G
Coplanar
Gage
★
T
In-Line
Gage
★
E
In-Line
Absolute
★
A
Coplanar
Absolute
Pressure range
Coplanar DP
Coplanar gage
In-Line gage
In-Line
absolute
Coplanar absolute
1A
N/A
N/A
-14.7 to 30 psig
(-1,01 to 2,06
bar)
0 to 30 psia
(0 to 2,06
bar)
0 to 30 psia
(0 to 2,06 bar)
★
2A
-250 to 250 inH2O
(-621,60 to 621,60
mbar)
-250 to 250 inH2O
(-621,60 to 621,60
mbar)
-14.7 to 150
psig
(-1,01 to 10,34
bar)
0 to 150 psia
(0 to 10,34
bar)
0 to 150 psia
(0 to 10,34 bar)
★
3A
-1000 to 1000 inH2O -393 to 1000 inH2O
(-2,48 to 2,48 bar)
(-0,97 to 2,48 bar)
-14.7 to 800
psig
(-1,01 to 55,15
bar)
0 to 800 psia
(0 to 55,15
bar)
0 to 800 psia
(0 to 55,15 bar)
★
4A
-300 to 300 psi
-14.2 to 300 psig
(-20,68 to 20,68 bar) (-0,97 to 20,68 bar)
-14.7 to 4000
psig
(-1,01 to 275,79
bar)
0 to 4000
psia
(0 to 275,79
bar)
0 to 4000 psia
(0 to 275,79 bar)
★
5A
-2000 to 2000 psi
(-137,89 to 137,89
bar)
-14.7 to 10000
psig
(-1,01 to 689,47
bar)
0 to 10000
psia
(0 to 689,47
bar)
N/A
★
-14.2 to 2000 psig
(-0,97 to 137,89
bar)
Transmitter output
A
4-20 mA with digital signal based on HART protocol
★
F(2)
FOUNDATION fieldbus protocol
★
X(3)
Wireless (Requires wireless options and wireless PlantWeb housing)
★
Housing style
Material
Conduit entry
1A
PlantWeb housing
Aluminum
1
★
1B
PlantWeb housing
Aluminum
M20 x 1.5
★
★
/2–14 NPT
1J
PlantWeb housing
SST
1/2–14 NPT
1K
PlantWeb housing
SST
M20 x 1.5
★
2A
Junction Box housing
Aluminum
1
★
2B
Junction Box housing
Aluminum
M20 x 1.5
★
2E
Junction Box with output for remote
interface
Aluminum
1/2–14 NPT
★
www.rosemount.com
/2–14 NPT
77
Rosemount 3051S Series
October 2014
Table 9. Rosemount 3051SAL Scalable Level Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
2F
Junction Box with output for remote
interface
Aluminum
M20 x 1.5
★
2J
Junction Box housing
SST
1
★
5A
Wireless PlantWeb housing
Aluminum
1
★
5J(4)
Wireless PlantWeb housing
SST
1
★
7J(5)
Quick Connect (A size Mini, 4-pin male
termination)
SST
1C
PlantWeb housing
Aluminum
G1/2
1L
PlantWeb housing
316L SST
G1/2
2C
Junction Box housing
Aluminum
G1/2
2G
Junction Box with output for remote
interface
Aluminum
G1/2
(4)
/2–14 NPT
/2–14 NPT
/2–14 NPT
★
Seal system type
Coplanar Pressure Module Type
1
Direct Mount Single Seal System
Welded-Repairable
★
2
Direct Mount Single Seal System
All Welded
★
3(6)
Tuned-System Assembly - 1 Direct Mount and 1 Remote Mount Seal with
Capillary
Welded-Repairable
★
4(6)
Tuned-System Assembly - 1 Direct Mount and 1 Remote Mount Seal with
Capillary
All Welded
★
5(6)
Balanced System - 2 Remote Mount Seals with Equal Lengths of Capillary
Welded-Repairable
★
(6)
Balanced System - 2 Remote Mount Seals with Equal Lengths of Capillary
All Welded
★
7
Remote Mount Single Seal System with Capillary - 316L Low Side Transmitter
Isolator
Welded-Repairable
★
8
Remote Mount Single Seal System with Capillary - 316L Low Side Transmitter
Isolator
All Welded
★
9
Remote Mount Single Seal System with Capillary - Alloy C-276 Low Side
Transmitter
Isolator
Welded-Repairable
★
A
Remote Mount Single Seal System with Capillary - Alloy C-276 Low Side
Transmitter
Isolator
All Welded
★
6
In-Line Pressure Module Type
1
Direct Mount Single Seal System
All Welded
★
7
Remote Mount Single Seal System with Capillary
Welded-Repairable
★
High side connection type
Direct Mount Single Seal System (between transmitter and remote seal)
0
No Extension
★
2
2-in. (50 mm) Extension
★
4
4-in. (100 mm) Extension
★
78
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 9. Rosemount 3051SAL Scalable Level Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
6(7)
Thermal Range Expander - Silicone 200 Secondary Fill Fluid
★
7(7)
Thermal Range Expander - SYLTHERM XLT Secondary Fill Fluid
★
Tuned-System Assembly
0
No Extension on Direct Mount High Side Connection
2
2-in. (50 mm) Extension on Direct Mount High Side Connection
★
4-in. (100 mm) Extension on Direct Mount High Side Connection
★
6
(7)
Thermal Range Expander - Silicone 200 Secondary Fill Fluid (both direct mount and remote mount capillary)
★
7
(7)
Thermal Range Expander - SYLTHERM XLT Secondary Fill Fluid (both direct mount and remote mount capillary)
★
4
Balanced System
0
6
(7)
7(7)
Standard Balanced System
★
Thermal Range Expander - Silicone 200 Secondary Fill Fluid (both remote mount capillaries)
★
Thermal Range Expander - SYLTHERM XLT Secondary Fill Fluid (both remote mount capillaries)
★
Remote Mount Single Seal System with Capillary
0
Standard Remote Mount Single Seal System with Capillary
★
6(7)
Thermal Range Expander - Silicone 200 Secondary Fill Fluid
★
7(7)
Thermal Range Expander - SYLTHERM XLT Secondary Fill Fluid
★
Low side connection type (reference pressure connection)
Direct Mount Single Seal System
0
None (In-Line Pressure Module Type Only)
★
1 (8)(14)
Assemble to One Rosemount 1199 Remote Seal
★
2
316L SST isolator and SST transmitter flange
★
3
Alloy C-276 isolator and SST transmitter flange
★
Tuned-System Assembly, Balanced, or Single Seal Capillary System
B
0.03-in. (0.711 mm) ID Capillary
★
C
0.04-in. (1.092 mm) ID Capillary
★
D
0.075-in. (1.905 mm) ID Capillary
★
E
0.03-in. (0.711 mm) ID Capillary, PVC Coated with Closed End
★
F
0.04-in. (1.092 mm) ID Capillary, PVC Coated with Closed End
★
G
0.075-in. (1.905 mm) ID Capillary, PVC Coated with Closed End
★
Capillary length(9)
0
No Capillary (required for Direct Mount Single Seal System)
★
A
1 ft (0.3 m)
★
B
5 ft (1.5 m)
★
C
10 ft (3.0 m)
★
D
15 ft (4.5 m)
★
www.rosemount.com
79
Rosemount 3051S Series
October 2014
Table 9. Rosemount 3051SAL Scalable Level Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
E
20 ft (6.1 m)
★
F
25 ft (7.6 m)
★
G
30 ft (9.1 m)
★
H
35 ft (10.7 m)
★
J
40 ft (12.2 m)
★
K
45 ft (13.7 m)
★
L
50 ft (15.2 m)
★
M
0.5 m (1.6 ft)
★
N
1.0 m (3.3 ft)
★
P
1.5 m (4.9 ft)
★
R
2.0 m (6.6 ft)
★
T
2.5 m (8.2 ft)
★
U
3.0 m (9.8 ft)
★
V
3.5 m (11.5 ft)
★
W
4.0 m (13.1 ft)
★
Y
5.0 m (16.4 ft)
★
Z
6.0 m (19.7 ft)
★
1
7.0 m (23 ft)
★
2
8.0 m (26.2 ft)
★
3
9.0 m (29.5 ft)
★
4
10.0 m (32.8 ft)
★
5
11.0 m (36.1 ft)
★
6
12.0 m (39.4 ft)
★
7
13.0 m (42.6 ft)
★
8
14.0 m (45.9 ft)
★
9
15.0 m (49.2 ft)
★
Temperature limits
Specific gravity
at 77 °F (25 °C)
Seal fill fluid
No extension
D
Silicone 200
0.93
F
Silicone 200 for
Vacuum Applications
0.93
80
-49 to 401 °F
(-45 to 205 °C)
(10)
4-in.
2-in. (50 mm)
(100 mm)
extension
extension
-49 to 401 °F
(-45 to 205 °C)
-49 to 401 °F
(-45 to 205 °C)
Thermal range
expander
(process
temperature)
(11)
N/A
For use in vacuum applications below 14.7 psia (1 bar-a), refer to vapor
pressure curves in Rosemount DP Level Fill Fluid Specification Technical
Note (00840-2100-4016).
★
★
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 9. Rosemount 3051SAL Scalable Level Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
32 to 401 °F(12)
(0 to 205 °C)
32 to 464 °F(12)
(0 to 240 °C)
32 to 500
°F(12)
(0 to 260 °C)
Up to 599 °F
(315 °C)
★
L
Silicone 704
1.07
C
Silicone 704 for
Vacuum Applications
1.07
R
Silicone 705
1.09
V
Silicone 705 for
Vacuum Applications
1.09
A
SYLTHERM XLT
0.85
-102 to 293 °F
(-75 to 145 °C)
-102 to 293 °F
(-75 to 145 °C)
-102 to 293 °F
(-75 to 145 °C)
N/A
★
H
Inert (Halocarbon)
1.85
-49 to 320 °F
(-45 to 160 °C)
-49 to 320 °F
(-45 to 160 °C)
-49 to 320 °F
(-45 to 160 °C)
N/A
★
G(13)(14)
Glycerine and Water
1.13
5 to 203 °F
(-15 to 95 °C)
5 to 203 °F
(-15 to 95 °C)
5 to 203 °F
(-15 to 95 °C)
N/A
★
N(13)
Neobee M-20
0.92
5 to 401 °F(12)
(-15 to 205 °C)
5 to 437 °F
(-15 to 225 °C)
5 to 437 °F
(-15 to 225 °C)
N/A
★
P (13)(14)
Propylene Glycol and
Water
1.02
5 to 203 °F
(-15 to 95 °C)
5 to 203 °F
(-15 to 95 °C)
5 to 203 °F
(-15 to 95 °C)
N/A
★
Y (15)
UltraTherm 805
1.20
N/A
N/A
N/A
Up to 770 °F
(410 °C)
★
Z(15)
UltraTherm 805 for
vacuum applications
1.20
For use in vacuum application below 14.7 psia (1 bar-a), refer to vapor
pressure curves in Rosemount DP Level Fill Fluid Specification Technical
Note 900840-2100-4016).
www.rosemount.com
For use in vacuum applications below 14.7 psia (1 bar-a), refer to vapor
pressure curves in Rosemount DP Level Fill Fluid Specification Technical
Note (00840-2100-4016).
★
68 to 500
68 to 464 °F(12)
°F(12)
(20 to 240 °C)
(20 to 260 °C)
★
68 to 401 °F(12)
(20 to 205 °C)
Up to 698 °F
(370 °C)
For use in vacuum applications below 14.7 psia (1 bar-a), refer to vapor
pressure curves in Rosemount DP Level Fill Fluid Specification Technical
Note (00840-2100-4016).
★
★
81
Rosemount 3051S Series
October 2014
Table 9. Rosemount 3051SAL Scalable Level Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Continue specifying a completed model number by choosing a remote seal type below:
Flanged seal assemblies
page 88
FF Flush Flanged Seal
Process Connections:
2-in. / DN 50 / 50A
3-in. / DN 80 / 80A
4 in. / DN 100 / 100A
EF Extended Flanged Seal
Process Connections:
3-in. / DN 80 / 80A
4-in. / DN 100 / 100A
page 93
RF Remote Flanged Seal
Process Connections:
½ in.
¾ in.
1-in. / DN 25 / 25A
1½-in. / DN 40 / 40A
page 96
PF Pancake Seal
2-in. / DN 50 / 50A
3-in. / DN 80 / 80A
page 98
FC Flush Flanged Seal - Ring Type Joint (RTJ) Gasket
Surface
2-in.
3-in.
RC Ring Type Joint (RTJ) Flanged Seal
½-in
¾-in
1 in.
1½ in.
RT Remote Threaded Seal
Process Connections:
¼ - 18 NPT
½ - 14 NPT
¾ - 14 NPT
1 - 11.5 NPT
1¼ - 11.5 NPT
page 104
SC Hygienic Tri-Clamp Seal
Process Connections:
1½-in.
2-in.
3-in.
page 105
SS Hygienic Tank Spud Seal
Process Connections:
4-in.
page 91
page 100
page 102
82
Process connections
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 9. Rosemount 3051SAL Scalable Level Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Wireless options (requires option code X and wireless PlantWeb housing)
Update rate
WA(4)
User Configurable Update Rate
★
Operating frequency and protocol
3
2.4 GHz DSSS, IEC 62591 (WirelessHART)
★
Omni-directional wireless antenna
WK(4)
External Antenna
★
WM(4)
Extended Range, External Antenna
★
WN
High-Gain, Remote Antenna
SmartPower
1(16)(17)
Adapter for Black Power Module (I.S. Power Module Sold Separately)
★
Other options (include with selected model number)
Extended product warranty
WR3
3-year limited warranty
★
WR5
5-year limited warranty
★
PlantWeb control functionality
A01(17)(18)(19)
FOUNDATION fieldbus Advanced Control Function Block Suite
★
PlantWeb diagnostic functionality
D01(17)(18)
FOUNDATION fieldbus Diagnostics Suite
★
DA2(20)
Advanced HART Diagnostics Suite
★
Mounting bracket
B4
Bracket, all SST, 2-in. pipe panel
★
Software configuration
C1(21)
Custom software configuration (requires Configuration Data Sheet)
★
Gage pressure calibration
Gage pressure calibration on Rosemount 3051SAL_ _A4 only
★
C4(18)(21)
NAMUR alarm and saturation levels, high alarm
★
C5(18)(21)
NAMUR alarm and saturation levels, low alarm
★
C6(18)(21)
Custom alarm and saturation signal levels, high alarm (requires C1 and Configuration Data Sheet)
★
C7(18)(21)
Custom alarm and saturation signal levels, low alarm (requires C1 and Configuration Data Sheet)
★
C8(18)(21)
Low alarm (standard Rosemount alarm and saturation levels)
★
C3
Alarm limit
www.rosemount.com
83
Rosemount 3051S Series
October 2014
Table 9. Rosemount 3051SAL Scalable Level Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Hardware adjustments
D1(18)(21)(22)
Hardware adjustments (zero, span, alarm, security)
★
Flange adapter
D2
1
D9
RC 1/2 SST flange adapter
/2-14 NPT flange adapter
★
Ground screw
D4(23)
External ground screw assembly
★
Drain/vent valve
D5
Delete transmitter drain/vent valves (install plugs)
★
316 SST Conduit Plug
★
Conduit plug
DO(24)
Product certifications(25)
E1
ATEX Flameproof
★
I1
ATEX Intrinsic Safety
★
IA
ATEX FISCO Intrinsic Safety (FOUNDATION fieldbus protocol only)
★
N1
ATEX Type n
★
K1
ATEX Flameproof, Intrinsic Safety, Type n, Dust
★
ND
ATEX Dust
★
E4
TIIS Flameproof
★
E5
FM Explosion-proof, Dust Ignition-proof
★
I5
FM Intrinsically Safe; Nonincendive
★
IE
FM FISCO Intrinsically Safe (FOUNDATION fieldbus protocol only)
★
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
★
E6(26)
CSA Explosion-proof, Dust Ignition-proof, Division 2
★
I6
CSA Intrinsically Safe
★
IF
CSA FISCO Intrinsically Safe (FOUNDATION fieldbus protocol only)
★
K6(26)
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
★
D3(27)
Measurement Canada Accuracy Approval
★
E7
IECEx Flameproof, Dust Ignition-proof
★
I7
IECEx Intrinsic Safety
★
IG
IECEx FISCO Intrinsic Safety (FOUNDATION fieldbus protocol only)
★
N7
IECEx Type n
★
K7
IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, Type n
★
E2
INMETRO Flameproof
★
84
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 9. Rosemount 3051SAL Scalable Level Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
I2
INMETRO Intrinsic Safety
★
IB
INMETRO FISCO Intrinsic Safety
★
K2
INMETRO Flameproof, Intrinsic Safety
★
E3
China Flameproof
★
I3
China Intrinsic Safety, Dust Ignition-proof
★
EP
Korea Flameproof
★
IP
Korea Intrinsic Safety
★
KP
Korea Flameproof, Intrinsic Safety
★
EM
Technical Regulations Customs Union (EAC) Flameproof
★
IM
Technical Regulations Customs Union (EAC) Intrinsic Safety
★
KM
Technical Regulations Customs Union (EAC) Flameproof, Intrinsic Safety
★
KA(26)
ATEX and CSA Flameproof, Intrinsically Safe, Division 2
★
KB(26)
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
★
KC
FM and ATEX Explosion-proof, Intrinsically Safe, Division 2
★
KD(26)
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe
★
Shipboard approvals
SBS
American Bureau of Shipping (ABS) Type Approval
★
SBV
Bureau Veritas (BV) Type Approval
★
SDN
Det Norske Veritas (DNV) Type Approval
★
SLL
Lloyds Register (LR) Type Approval
★
Sensor fill fluid
L1(28)
Inert sensor fill fluid
★
Graphite-filled PTFE O-ring
★
O-ring
L2
Bolting material
L4
Austenitic 316 SST bolts
★
L5(29)
ASTM A193, Grade B7M bolts
★
L6
Alloy K-500 bolts
★
ASTM A453, Class D, Grade 660 bolts
★
ASTM A193, Class 2, Grade B8M bolts
★
L7
(29)
L8
Display type(30)
M5(18)(31)(32)
PlantWeb LCD display
★
M7(18)(31)
Remote mount LCD display and interface, PlantWeb housing, no cable, SST bracket
★
M8(18)(31)
Remote mount LCD display and interface, PlantWeb housing, 50 ft. (15 m) cable, SST bracket
★
M9(18)(31)
Remote mount LCD display and interface, PlantWeb housing, 100 ft. (31 m) cable, SST bracket
★
www.rosemount.com
85
Rosemount 3051S Series
October 2014
Table 9. Rosemount 3051SAL Scalable Level Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Pressure testing
P1
Hydrostatic testing with certificate
Special cleaning
P2
Cleaning for special services
P3
Cleaning for less than 1PPM Chlorine/Fluorine
Calibration certification
Q4
Calibration certificate
★
QP
Calibration certificate and tamper evident seal
★
Material traceability certification
Q8
★
Material traceability certification per EN 10204 3.1
Quality certification for safety
QS(18)(21)
Prior-use certificate of FMEDA Data
★
QT(33)
Safety-certified to IEC 61508 with certificate of FMEDA data
★
Toolkit performance reports
QZ
★
Remote Seal System Performance Calculation Report
Transient protection
T1(34)(35)
★
Transient terminal block
Conduit electrical connector
GE(36)
M12, 4-pin, Male Connector (eurofast)
★
GM(36)
A size Mini, 4-pin, Male Connector (minifast)
★
NACE certificate
Q15(29)
(29)
Q25
Certificate of Compliance to NACE MR0175/ISO 15156 for wetted materials
★
Certificate of Compliance to NACE MR0103 for wetted materials
★
Typical model number:
3051SAL 1 C G 2A A 1A 10 20 D FF G 1 DA 0 0
(1) For detailed specifications see “Specifications” on page 107.
(2) Requires PlantWeb housing.
(3) Only intrinsically safe approval codes apply.
(4) Only available with output code X.
(5) Available with output code A only. Available approvals are FM Intrinsically Safe; Nonincendive (option code I5), CSA Intrinsically Safe (option code I6), ATEX Intrinsic
Safety (option code I1), or IECEx Intrinsic Safety (option code I7). Contact an Emerson Process Management representative for additional information.
(6) Low side seal identical to high side seal.
(7) Maximum working pressure (MWP) of the Thermal Range Expander is 1500 psi (103,4 bar).
(8) Requires separate Rosemount 1199 model number to be selected. With option code 1, user must select Seal Location Option code M (low side of transmitter) in the
Rosemount 1199 Remote Mount Seal System Model.
86
www.rosemount.com
October 2014
Rosemount 3051S Series
(9) Capillary Length applies to both high and low side for Balanced Systems. Applies to Low Side Only For Tuned-System Assemblies. Applies to High Side Only for Remote
Mount Single Seal Systems with Capillary.
(10) At ambient pressure of 14.7 psia (1 bar-a) and ambient temperature of 70 °F (21 °C). Temperature limits are reduced in vacuum service and may be limited by seal
selection.
(11) For complete process and ambient temperature limits, see “Thermal Range Expander temperature operating range” on page 126.
(12)Maximum process temperature is limited by heat transfer to the transmitter electronics and must be further derated if ambient temperature
exceeds 70 °F (21 °C).
(13) This is a food grade fill fluid.
(14) Not suitable for vacuum applications.
(15) Only available with Thermal Range Expander
(16) Long-Life Power Module must be shipped separately, order Power Module 701PBKKF.
(17) Not available with output code A.
(18) Not available with output code X.
(19) With option code 10, user must select Seal Location option code M in Table 7 of Rosemount DP Level PDS.
(20) Requires PlantWeb housing and Output code A. Includes Hardware Adjustments as standard.
(21) Not available with output code F.
(22) Not available with housing style codes 2E, 2F, 2G, 2M, 5A, 5J, or 7J.
(23) This assembly is included with options EP, KP, E1, N1, K1, ND, E4, E7, N7, K7, E2, E3, KA, KC, KD. IA, IB, IE. IF, IG, K2, T1, EM, and KM.
(24) Transmitter is shipped with 316 SST conduit plug (uninstalled) in place of carbon steel conduit plug.
(25) Valid when SuperModule Platform and housing have equivalent approvals.
(26) Not available with M20 or G ½ conduit entry size.
(27) Requires PlantWeb housing and Hardware Adjustments option code D1. Limited availability depending on transmitter type and range. Contact an Emerson Process
Management representative for additional information.
(28) Silicone fill fluid is standard.
(29) Materials of construction comply with metallurgical requirements highlighted within NACE MR0175 / ISO 15156 for sour oil field production environments.
Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
Order with Q15 or Q25 to receive a NACE certificate.
(30) Not available with Housing code 01 or 7J.
(31) Not available with output code F, option code DA2, or option code QT.
(32) See the 3051S Reference Manual (document number 00809-0100-4801) for cable requirements. Contact an Emerson Process Management representative for
additional information.
(33) Not available with output code F or X. Not available with housing code 7J.
(34) Not available with Housing code 5A, 5J, or 7J.
(35) The T1 option is not needed with FISCO Product Certifications; transient protection is included in the FISCO product certification codes IA, IB, IE, IF, and IG.
(36) Not available with Housing code 5A, 5J, or 7J. Available with Intrinsically Safe approvals only. For FM Intrinsically Safe; Nonincendive (option code I5) or FM FISCO
Intrinsically Safe (option code IE), install in accordance with Rosemount drawing 03151-1009.
www.rosemount.com
87
Rosemount 3051S Series
October 2014
Diaphragm seals for 3051SAL
Flush Flanged (FF) Seal

Most common seal

Good for use in general applications

Easy installation on flanged connections ranging from 2-in. (DN 50) to 4-in. (DN 100)
Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See
page 127 for more information on Material Selection.
Table 10. Flush Flanged (FF) Seal Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model
Process connection
FF
Flush Flanged Seal
Process connection size
ANSI/ASME B16.5
EN 1092-1/GOST 12815-80
JIS B2238
G
2-in.
DN 50
50 A
★
7
3-in.
N/A
80 A
★
J
N/A
DN 80
N/A
★
9
4-in.
DN 100
100 A
★
Flange/pressure rating
1
ANSI/ASME B16.5 Class 150
★
2
ANSI/ASME B16.5 Class 300
★
4
ANSI/ASME B16.5 Class 600
★
G
PN 40 per EN 1092-1
★
5
ANSI/ASME B16.5 Class 900
6
ANSI/ASME B16.5 Class 1500
7
ANSI/ASME B16.5 Class 2500
H
PN 63 per EN 1092-1
J
PN 100 per EN 1092-1
A
10K per JIS B2238
B
20K per JIS B2238
D
40K per JIS B2238
E
PN 10/16 per EN 1092-1, Available with DN 100 only
Materials of construction
Isolating diaphragm
Upper housing
Flange
CA
316L SST
316L SST
CS
★
DA
316L SST
316L SST
316 SST
★
88
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 10. Flush Flanged (FF) Seal Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
CB(1)
Alloy C-276
316L SST
CS
★
(1)
Alloy C-276
316L SST
316 SST
★
CC
Tantalum
316L SST
CS
★
DC
Tantalum
316L SST
316 SST
★
DB
Flushing connection ring (lower housing)(2)
0
None
★
A
316 SST
★
B
Alloy C-276
★
Flushing connection quantity & size
0
None
★
1
1
One /4-18 NPT Flushing Connection
★
3
Two 1/4-18 NPT Flushing Connections
★
7
One 1/2-14 NPT Flushing Connection
★
9
1
Two /2-14 NPT Flushing Connections
★
Options (include with selected model number)
Cold temperature remote seal applications
SB
Extra Fill Fluid for Cold Temperature Applications
Remote seal diaphragm thickness
SC(3)
0.006-in. (150 μm) Diaphragm Thickness
Flushing connection ring plugs
SD
Alloy C-276 Plug(s) for Flushing Connection(s)
★
SG
SST Plug(s) for Flushing Connection(s)
★
SH
SST Drain/Vent(s) for Flushing Connection(s)
★
Flushing connection ring gaskets
S0
No gasket for lower housing
★
SY
Thermo-tork TN-9000
★
SJ
PTFE Gasket
★
SK
Barium Sulfate-Filled PTFE Gasket
SN
Grafoil Gasket
Remote seal diaphragm coating
SZ(3)
0.0002-in. (5 μm) Gold Plated Diaphragm
SV
PTFE Coated Diaphragm for Non-Stick Purposes
www.rosemount.com
89
Rosemount 3051S Series
October 2014
Table 10. Flush Flanged (FF) Seal Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Complete the 3051SAL model number by specifying options as needed:
page 71
ERS Transmitter Options
page 83
Scalable Level Transmitter Options
(1) Not available with option code SC.
(2) Supplied with Thermo-tork TN-9000 gasket if no other flushing connection ring gasket option is selected.
(3) Not available with Tantalum diaphragms (Material of Construction codes CC and DC).
90
www.rosemount.com
October 2014
Rosemount 3051S Series
Extended Flanged (EF) Seal

Good for use in viscous applications with plugging issues

Seal diaphragm installed flush with inner tank wall to prevent process plugging

Easy installation on 3-in. (DN 80) and 4-in. (DN 100) flanged connections
Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See
page 127 for more information on Material Selection.
Table 11. Extended Flanged (EF) Seal Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model
Process connection
EF
Extended Flanged Seal
Process connection size
ANSI/ASME B16.5
EN 1092-1/GOST 12815-80
JIS
B2238
Extension
diameters
7
3-in. Schedule 80
DN 80
80A
2.58-in. (66 mm)
★
9
4-in. Schedule 80
DN 100
100A
3.50-in. (89 mm)
★
Flange/pressure rating
1
ANSI/ASME B16.5 Class 150
★
2
ANSI/ASME B16.5 Class 300
★
4
ANSI/ASME B16.5 Class 600
★
G
PN 40 per EN 1092-1
★
5
ANSI/ASME B16.5 Class 900
6
ANSI/ASME B16.5 Class 1500
7
ANSI/ASME B16.5 Class 2500
H
PN 63 per EN 1092-1
J
PN 100 per EN 1092-1
A
10K per JIS B2238
B
20K per JIS B2238
D
40K per JIS B2238
E
PN 10/16 per EN 1092-1, Available with DN 100 only
Materials of construction
Isolating diaphragm
Extension/gasket surface
Mounting flange
CA
316L SST
316L SST
CS
★
DA
316L SST
316L SST
316 SST
★
CB
Alloy C-276
Alloy C-276
CS
★
DB
Alloy C-276
Alloy C-276
316 SST
★
www.rosemount.com
91
Rosemount 3051S Series
October 2014
Table 11. Extended Flanged (EF) Seal Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Seal extension length
20
2-in. (50 mm)
★
40
4-in. (100 mm)
★
60
6-in. (150 mm)
★
Options (include with selected model number)
Cold temperature remote seal applications
SB
Extra Fill Fluid for Cold Temperature Applications
★
Remote seal diaphragm thickness
SC
0.006-in. (150 μm) Diaphragm Thickness
Remote seal diaphragm coating
SZ
0.0002-in. (5 μm) Gold Plated Diaphragm
SV
PTFE Coated Diaphragm for Non-Stick Purposes
Complete the 3051SAL model number by specifying options as needed:
page 71
ERS Transmitter Options
page 83
Scalable Level Transmitter Options
92
www.rosemount.com
October 2014
Rosemount 3051S Series
Remote Flanged (RF) Seal

Designed to improve performance on smaller process connections

Easy installation on flanged connections ranging from 1-in. to 1.5-in. (DN 25– DN 40)

Lower housing/flushing ring required
Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See
page 127 for more information on Material Selection.
Table 12. Remote Flanged (RF) Seal Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model
Process connection
RF
Remote Flanged Seal
Process connection size
ANSI/ASME B16.5
EN 1092-1/GOST 12815-80
JIS B2238
2
1-in.
N/A
25A
★
4
11/2.-in.
N/A
40A
★
D
N/A
DN 25
N/A
★
F
N/A
DN 40
N/A
★
1
1
/2-in.
N/A
N/A
A
3/4-in.
N/A
N/A
Flange/pressure rating
1
ANSI/ASME B16.5 Class 150
★
2
ANSI/ASME B16.5 Class 300
★
4
ANSI/ASME B16.5 Class 600
★
G
PN 40 per EN 1092-1
★
5
ANSI/ASME B16.5 Class 900
6
ANSI/ASME B16.5 Class 1500
7
ANSI/ASME B16.5 Class 2500
A
10K per JIS B2238
B
20K per JIS B2238
D
40K per JIS B2238
Materials of construction
Isolating diaphragm
Upper housing
Flange
CA
316L SST
316L SST
CS
★
DA
316L SST
316L SST
316 SST
★
CB
Alloy C-276
316L SST
CS
★
www.rosemount.com
93
Rosemount 3051S Series
October 2014
Table 12. Remote Flanged (RF) Seal Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
DB
Alloy C-276
316L SST
316 SST
★
CC
Tantalum
316L SST
CS
★
DC
Tantalum
316L SST
316 SST
★
Flushing connection ring material (lower housing)(1)
A
316L SST
★
B
Alloy C-276
★
D
Plated CS
★
Flushing connection quantity and size
5
None
★
1
One ¼-18 NPT Flushing Connection
★
3
Two ¼-18 NPT Flushing Connections
★
7
One 1/2-14 NPT Flushing Connection
9
Two 1/2-14 NPT Flushing Connections
Options (include with selected model number)
Cold temperature remote seal application
SB
Extra Fill Fluid for Cold Temperature Applications
★
Remote seal diaphragm thickness
SC(2)
0.006-in. (150 μm) Diaphragm Thickness
Flushing connection ring plugs
SD
Alloy C-276 Plug(s) for Flushing Connection(s)
★
SG
316 SST Plug(s) for Flushing Connection(s)
★
SH
316 SST Drain/Vent(s) for Flushing Connection(s)
★
Flushing ring connection gaskets
SY
C-4401 Gasket
★
SJ
PTFE Gasket
★
SR
Ethylene Propylene Gasket
SN
Grafoil Gasket
S6
TopChem 2000
SK
Barium Sulfate-Filled PTFE Gasket
Remote seal diaphragm coating
SZ(2)
0.0002-in. (5 μm) Gold Plated Diaphragm
SV
PTFE Coated Diaphragm for Non-Stick Purposes
94
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 12. Remote Flanged (RF) Seal Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Complete the 3051SAL model number by specifying options as needed:
page 71
ERS Transmitter Options
page 83
Scalable Level Transmitter Options
(1) Supplied with C-4401 Aramid fiber gasket if no other remote seal gasket material is selected.
(2) Not available with Tantalum diaphragms (Material of Construction codes CC and DC).
www.rosemount.com
95
Rosemount 3051S Series
October 2014
PF Pancake Seal
Table 13. PF Pancake Seal Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model
Process connection
PF
Pancake Seal
★
Process connection size
ANSI
EN 1092-1/GOST 12815-80
JIS B2238
G
2-in.
DN 50
50A
★
7
3-in.
N/A
80A
★
J
N/A
DN 80
N/A
★
Flange/pressure rating
ANSI
EN 1092-1/GOST 12815-80
0
No flanged supplied, seal MWP based on customer
supplied flange
N/A
★
9
N/A
No flanged supplied, seal MWP based on customer
supplied flange
★
1
Class 150
N/A
★
2
Class 300
N/A
★
4
Class 600
N/A
★
G
N/A
PN40
★
5
Class 900
N/A
6
Class 1500
N/A
7
Class 2500
N/A
H
N/A
PN63
J
N/A
PN100
Diaphragm and wetted, upper housing, flange material
Diaphragm and wetted
Upper housing
Flange
LA(1)
316L SST
316L SST
None
★
CA(1)
316L SST
316L SST
CS
★
DA(1)
316L SST
316L SST
316 SST
★
LB
Alloy C-276, Seam Welded
316L SST
None
★
CB
Alloy C-276, Seam Welded
316L SST
CS
★
DB
Alloy C-276, Seam Welded
316L SST
316 SST
★
LC
Tantalum, Seam Welded
316L SST
None
★
CC
Tantalum, Seam Welded
316L SST
CS
★
DC
Tantalum, Seam Welded
316L SST
316 SST
★
96
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 13. PF Pancake Seal Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Flushing connection ring (lower housing)(2)
0
None
★
A
316 SST
★
B
Alloy C-276
★
Flushing connection quantity & size
0
None
★
1
1
One /4-18 NPT Flushing Connection
★
3
Two 1/4-18 NPT Flushing Connections
★
7
One 1/2-14 NPT Flushing Connection
★
9
Two 1/2-14 NPT Flushing Connections
★
Options (include with selected model number)
Flushing connection ring gaskets
S0
No gasket for lower housing
★
SY
Thermo-tork TN-9000
★
SJ
PTFE Gasket
★
SK
Barium Sulfate-Filled PTFE Gasket
SN
Grafoil Gasket
Flushing connection ring plugs
SD
Alloy C-276 Plug(s) for Flushing Connection(s)
★
SG
SST Plug(s) for Flushing Connection(s)
★
SH
SST Drain/Vent(s) for Flushing Connection(s)
★
Remote seal diaphragm thickness
SC(3)
0.006-in. (150 μm) Diaphragm Thickness
Cold temperature remote seal applications
SB
Extra Fill Fluid for Cold Temperature Applications
Remote seal diaphragm coating
SZ(3)
0.0002-in. (5 μm) Gold Plated Diaphragm
SV
PTFE Coated Diaphragm for Non-Stick Purposes
Complete the 3051SAL model number by specifying options as needed:
page 83
Scalable Level Transmitter Options
(1) For use with customer supplied spiral metallic gaskets.
(2) Supplied with Thermo-tork TN-9000 gasket if no other flushing connection ring gasket option is selected.
(3) Not available with Tantalum diaphragms (Material of Construction codes CC and DC).
www.rosemount.com
97
Rosemount 3051S Series
October 2014
FC Flush Flanged Seal - Ring Type Joint (RTJ) Gasket Surface
Table 14. FC Flush Flanged Seal - Ring Type Joint (RTJ) Gasket Surface Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
_The Expanded offering is subject to additional delivery lead time.
Model
Process connection
FC
Flush Flanged Seal - Ring Type Joint Gasket Surface
Process connection size
G
2-in.
7
3-in.
Flange/pressure rating
1
Class 150
2
Class 300
4
Class 600
5
Class 900
6
Class 1500
7
Class 2500
Diaphragm and wetted, upper housing, flange material
Diaphragm and wetted
Upper housing
Flange
DA
316L SST
316L SST
316 SST
KB
Alloy C-276
316L SST
316 SST
MB
Alloy C-276
316L SST
CS
CA
316L SST
316L SST
CS
Flushing connection ring material (lower housing)
0
None
A
316 SST
B
Alloy C-276
2
Duplex 2205 SST
Flushing connection quantity and size
0
None
1
One 1/4-18 NPT Flushing Connection
3
Two 1/4-18 NPT Flushing Connection
7
One 1/2-14 NPT Flushing Connection
9
Two 1/2-14 NPT Flushing Connection
98
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 14. FC Flush Flanged Seal - Ring Type Joint (RTJ) Gasket Surface Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
_The Expanded offering is subject to additional delivery lead time.
Options (include with selected model number)
Flushing ring connection plugs
SD
Alloy C-276 plug(s) for flushing connection(s)
SG
316 SST plug(s) for flushing connection(s)
SH
316 SST vent/drain for flushing connection(s)
Remote seal diaphragm thickness
SC
0.006-in. (150 μm) available with 316L SST, Alloy C-276, and duplex 2507 SST for abrasive applications
Cold temperature remote seal application
SB
Extra fill for cold temp application
Remote seal diaphragm coating
SZ(1)
0.002-in. (5 μm) Gold plated diaphragm
SV(1)
PTFE coated diaphragm for nonstick purposes only
Complete the 3051SAL model number by specifying options as needed:
page 71
ERS Transmitter Options
page 83
Scalable Level Transmitter Options
(1) Only available on 316LSST and Alloy C-276.
www.rosemount.com
99
Rosemount 3051S Series
October 2014
RC Ring Type Joint (RTJ) Flanged Seal
Table 15. RC Ring Type Joint Flanged Seal Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
_The Expanded offering is subject to additional delivery lead time.
Model
Process connection
RC
Flush Flanged Seal - Ring Type Joint Gasket Surface
Process connection size
1
1
A
3/ -in. (Class 150 includes mounting ring bolts and mounting studs)
4
2
1-in.
4
11/2-in.
/2-in. (Class 150 to 1500 includes mounting ring bolts and mounting studs)
Flange/pressure rating
1
Class 150
2
Class 300
4
Class 600
5
Class 900
6
Class 1500
7
Class 2500
Diaphragm and wetted, upper housing, flange material
Diaphragm and wetted
Upper housing
Flange
DA
316L SST
316L SST
316 SST
DB
Alloy C-276
316L SST
316 SST
DC
Tantalum
316L SST
316 SST
Flushing connection ring material (lower housing)
A
316L SST
B
Alloy C-276
F
304L SST
H
Titanium Grade 4
2
Duplex 2205 SST
V
Alloy 400
Flushing ring connection and size
0
None
1
One 1/4-18 NPT Flushing Connections
3
Two 1/4-18 NPT Flushing Connection
7
One 1/2-14 NPT Flushing Connection
9
Two 1/2-14 NPT Flushing Connection
100
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 15. RC Ring Type Joint Flanged Seal Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
_The Expanded offering is subject to additional delivery lead time.
Options (include with selected model number)
Flushing connection ring gaskets
SY
C-4401 Gasket
★
SJ
PTFE Gasket
★
SR
Ethylene Propylene Gasket
SN
Grafoil Gasket
S6
TopChem 2000
SK
Barium Sulfate-Filled PTFE Gasket
Flushing connection ring plugs
SD
Alloy C-276 plug(s) for flushing connection(s)
SG
316 SST plug(s) for flushing connection(s)
SH
316 SST vent/drain for flushing connection(s)
Remote seal diaphragm thickness
C
0.006-in. (150 μm) available with 316L SST, Alloy C-276, and duplex 2507 SST for abrasive applications
Bolt material (optional)
3(1)
304 SST Bolts (only available for Stud Bolt Design)
Cold temperature remote seal application
SB
Extra fill for cold temp application
Remote seal diaphragm coating
SZ(2)
0.002-in. (5 μm) Gold plated diaphragm
SV(1)
PTFE coated diaphragm for nonstick purposes only
Complete the 3051SAL model number by specifying options as needed:
page 71
ERS Transmitter Options
page 83
Scalable Level Transmitter Options
(1) Standard stud bolts are Carbon Steel.
(2) Only available on 316LSST and Alloy C-276.
www.rosemount.com
101
Rosemount 3051S Series
October 2014
Remote Threaded (RT) Seal

For use with threaded process connections (1/4-18 to 1-11.5 NPT)

Rated for use in high-pressure applications (up to 2500 PSI)

Optional flushing connections available
Table 16. RT Threaded Seal Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model
Process connection
RT
Remote Threaded Seal
★
Process connection size
3
1/2-14 NPT
★
4
3/4-14 NPT
★
5
1-11.5 NPT
★
1
1/4-18 NPT
6
11/4 - 11.5 NPT
Pressure rating
0
★
2500 psi
Isolating diaphragm material
Upper housing material
Flange
CA
316L SST
316L SST
CS
★
DA
316L SST
316L SST
316 SST
★
CB
Alloy C-276
316L SST
CS
★
DB
Alloy C-276
316L SST
316 SST
★
CC
Tantalum
316L SST
CS
★
DC
Tantalum
316L SST
316 SST
★
Flushing connection ring material (lower housing)(1)(2)
A
316L SST
★
B
Alloy C-276
★
D
Plated CS
Flushing ring connection quantity & size
5
None
★
1
One 1/4-in. Flushing Connection
★
3
1
Two /4-in. Flushing Connections
7
One /2-14 NPT Flushing Connection
9
Two 1/2-14 NPT Flushing Connection
102
★
1
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 16. RT Threaded Seal Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Options (include with selected model number)
Cold temperature remote seal application
SB
Extra Fill Fluid for Cold Temperature Applications
★
Remote seal diaphragm thickness
SC(3)
0.006-in. (150 μm) Diaphragm Thickness
Remote seal flushing plug, drain/vent
SD
Alloy C-276 Plug(s) for Flushing Connection(s)
★
SG
316 SST Plug(s) for Flushing Connection(s)
★
SH
316 SST Drain/Vent(s) for Flushing Connection(s)
★
Remote seal gasket material
SY
C-4401 Gasket (for use with Flushing Connection Ring)
★
SJ
PTFE Gasket (for use with Flushing Connection Ring)
★
SR
Ethylene Propylene Gasket (for use with Flushing Connection Ring)
★
SN
Grafoil Gasket (for use with Flushing Connection Ring)
★
S6
TopChem 2000 (for use with Flushing Connection Ring)
SK
Barium Sulfate-Filled PTFE Gasket (for use with Flushing Connection Ring)
Remote seal bolt
S3
304 SST Bolts
S4
316 SST Bolts
★
Remote seal diaphragm coating
SZ(3)
0.0002-in. (5 μm) Gold Plated Diaphragm
SV
PTFE Coated Diaphragm for Non-Stick Purposes
Special threads in lower housing
R9
Male Lower Housing Threads
Complete the 3051SAL model number by specifying options as needed:
page 71
ERS Transmitter Options
page 83
Scalable Level Transmitter Options
(1) Supplied with C4401 aramid fiber gasket if no other remote seal gasket material is selected.
(2) Flushing Connection Ring/ Lower Housing assembly bolts provided as standard are carbon steel.
(3) Not available with Tantalum diaphragms (Material of Construction codes CC and DC).
www.rosemount.com
103
Rosemount 3051S Series
October 2014
Hygienic Tri-Clamp (SC) Seal

Good for use in hygienic applications

Easy installation on Tri-Clover style Tri-Clamp connections (1.5-in. to 3-in.)

Conforms to 3-A standard 74-03
Table 17. SC Hygienic Tri-Clover Style Tri-Clamp Seal Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Process connection
SC(1)
★
Tri-Clover Style Tri-Clamp Seal
Process connection size
3(2)(3)
1½-in.
★
5(2)(4)
2-in.
★
7
3-in.
★
Maximum working pressure
0
★
1000 PSI
Isolating diaphragm material
Upper housing material
LA00
316L SST
316L SST
LB00
Alloy C-276
316L SST
★
Options (include with selected model number)
Remote seal diaphragm polishing
R6
Electropolishing
Remote seal diaphragm surface finish
RD
10 μin. (0.25 μm) Ra Diaphragm Surface Finish
RG
15 μin. (0.375 μm) Ra Diaphragm Surface Finish
RH
20 μin. (0.5 μm) Ra Diaphragm Surface Finish
Surface finish certification
Q16(5)
Surface Finish Certification for Hygienic Remote Seals
★
Complete the 3051SAL model number by specifying options as needed:
page 71
ERS Transmitter Options
page 83
Scalable Level Transmitter Options
(1) Clamp and gasket furnished by user. The maximum working pressure is dependent upon the clamp pressure rating.
(2) Consult factory for calibrated spans lower than 5 psi (345 mbar).
(3) 1000 inH2O or 2490 mbar for 1-1/2-in. SC.
(4) 150 inH2O or 373 mbar for 2-in. SC.
(5) Q16 is only available when the diaphragm seal has surface finish options (RD, RG, and RH).
104
www.rosemount.com
October 2014
Rosemount 3051S Series
Hygienic Tank Spud (SS) Seal

Commonly used in hygienic level applications

Seal diaphragm installed flush with inner tank wall

Conforms to 3-A standard 74-03
Table 18. SS Hygienic Tank Spud Seal Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Process connection
SS(1)
★
Hygienic Tank Spud Seal
Process connection size
A
★
4-in. Sch. 5 Tri-Clamp
Maximum working pressure (clamp rating)
0
★
600 PSI (41,37 bar)
Upper housing
A
★
316L SST
Diaphragm and wetted, extension material
Diaphragm and wetted
Extension
AL
316L SST(2)
316L SST(2)
BB
Alloy C-276
316L SST
★
Extension length
2
2-in. (50 mm) Extension
★
6
6-in. (150 mm) Extension
★
Options (include with selected model number)
Remote seal diaphragm thickness
SC
0.006-in. (150 μm) Diaphragm Thickness
Tank spud included with shipment
S1
Tank Spud Included with Shipment
★
Remote seal diaphragm polishing
R6
Electropolishing
Remote seal diaphragm surface finish
RH
20 μin. (0.5 μm) Ra Diaphragm Surface Finish
RG(3)
15 μin. (0.375 μm) Ra Diaphragm Surface Finish
www.rosemount.com
105
Rosemount 3051S Series
October 2014
Table 18. SS Hygienic Tank Spud Seal Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Additional options
Surface finish certification
Q16(4)
Surface Finishing Certification for Hygienic Remote Seals
★
Complete the 3051SAL model number by specifying options as needed:
page 71
ERS Transmitter Options
page 83
Scalable Level Transmitter Options
(1) Clamp and Ethylene Propylene O-ring (conforms to 3-A standard 74 and USP class VI) supplied.
(2) Diaphragm brazed and TIG-welded to extension.
(3) Require Option code R6 (Electropolishing).
(4) Q16 is only available when the diaphragm seal has surface finish options (RG and RH).
106
www.rosemount.com
October 2014
Rosemount 3051S Series
Specifications
Performance specifications
Conformance to specification (±3σ [Sigma])
For zero-based spans, reference conditions, silicone oil fill,
glass-filled PTFE O-rings, SST materials, coplanar flange
(3051SMV, 3051S_C) or 1/2 in.- 14 NPT (3051S_T) process
connections, digital trim values set to equal range points.
Technology leadership, advanced manufacturing techniques,
and statistical process control ensure pressure measurement
specification conformance to ±3σ or better.
Reference accuracy
Stated reference accuracy equations include terminal based
linearity, hysteresis, and repeatability.
For FOUNDATION fieldbus and wireless devices, use calibrated
range in place of span.
Transmitter with coplanar sensor module (single variable)(1)
Differential pressure (3051S_CD, 3051SMV_ _ 3 or 4)
Gage pressure (3051S_CG, 3051SAM_ _G(2))
Ultra for Flow(3)
Ultra
Classic
Ranges 2 - 4
±0.025% of span;
For spans less than 10:1,
±[0.005 + 0.0035(URL / Span)]% of
span
±0.04% of reading up to 8:1
±0.035% of span;
DP turndown from URL;
For spans less than 10:1,
±[0.04 + 0.0023(URL /
±[0.015 + 0.005(URL / Span)]% of span Reading)]% of reading to
200:1 DP turndown from URL
Range 5
±0.05% of span;
For spans less than 10:1,
±[0.005 + 0.0045(URL / Span)]% of
span
±0.065% of span;
N/A
For spans less than 10:1,
±[0.015 + 0.005(URL / Span)]% of span
Range 1
±0.09% of span;
For spans less than 15:1,
±[0.015 + 0.005(URL / Span)]% of
span
±0.10% of span;
For spans less than 15:1,
N/A
±[0.025 + 0.005(URL / Span)]% of span
Range 0
±0.09% of span;
For spans less than 2:1,
±0.045% of URL
±0.10% of span;
For spans less than 2:1,
±0.05% of URL
N/A
Absolute pressure (3051S_CA, 3051SAM_ _A(2))
Ultra
Classic
Ranges 1 - 4
±0.025% of span;
For spans less than 10:1,
±[0.004(URL / Span)]% of span
±0.035% of span;
For spans less than 10:1,
±[0.0065(URL / Span)]% of span
Range 0
±0.075% of span;
For spans less than 5:1,
±[0.025 + 0.01(URL / Span)]% of
span
±0.075% of span;
For spans less than 5:1,
±[0.025 + 0.01(URL / Span)]% of span
(1)
For 3051S Transmitters assembled to 1199 remote seals, use 3051SAL specifications.
(2) Specifications are for each gage/absolute pressure sensor of the ERS system and are not reflective of the DP calculation.
(3) Ultra for Flow is only available for 3051S_CD ranges 2-3. For calibrated spans from 1:1 to 2:1 of URL, add ±0.005% of span analog output error.
www.rosemount.com
107
Rosemount 3051S Series
October 2014
Transmitter with In-Line sensor module(1)
Absolute pressure (3051S_TA, 3051SAM_ _E(2))
Gage pressure (3051S_TG, 3051SAM_ _T(2))
Ultra
Classic
Ranges 1 - 4
±0.025% of span
For spans less than 10:1,
±[0.004(URL / Span)]% of span
±0.035% of span
For spans less than 10:1,
±[0.0065(URL / Span)]% of span
Range 5:
±0.04% of span. For spans less than
10:1 ±0.004% of URL.
±0.065% of span. For spans less than 10:1 ±0.0065% of URL.
(1)
For 3051S transmitters assembled to 1199 remote seals, use 3051SAL specifications.
(2) Specifications are for each gage / absolute pressure sensor of the ERS system and are not reflective of the DP calculation.
Transmitter with MultiVariable sensor module(1)
Differential pressure and static pressure (3051SMV_ _1 or 2)
Classic MV
Ultra for Flow(2)
DP Ranges 2-3
±0.04% of span
For spans less than 10:1,
±[0.01 + 0.004(URL / Span)]% of
span
±0.04% of reading up to 8:1 DP turndown from URL
±[0.04 + 0.0023(URL / Reading)]% of reading to 200:1 DP turndown
from URL
DP Range 4
±0.055% of span
For spans less than 10:1,
±[0.015 + 0.005(URL/Span)]% of
span
±0.05% of reading up to 3:1 DP turndown from URL
±[0.05 + 0.0145(URL/RDG)]% of reading to 100:1 DP turndown from
URL
DP Range 5
±0.065% of span
For spans less than 10:1,
±[0.015 + 0.005(URL/Span)]% of
span
N/A
DP Range 1
±0.10% of span
For spans less than 15:1,
±[0.025 + 0.005(URL / Span)]% of
span
N/A
AP & GP Ranges
3-4(3)
±0.055% of span
For spans less than 10:1,
±[0.0065(URL / Span)]% of span
±0.025% of span
For spans less than 10:1,
±[0.004(URL / Span)]% of span
(1)
For 3051S Transmitters assembled to 1199 remote seals, use 3051SAL specifications.
(2) Ultra for Flow is only available for 3051SMV DP ranges 2-4. For calibrated DP spans from 1:1 to 2:1 of URL, add ±0.005% of span analog output error.
(3) For DP range 4 or 5, Classic MV and Ultra for Flow static pressure accuracy is +/-0.055% of span. For spans less than 5:1, +/-[0.013(URL/Span)]% of span.
Liquid level transmitter
3051SAL
Ranges 2 - 5
108
Ultra
Classic
±0.055% of span
For spans less than 10:1,
±[0.015 + 0.005(URL / Span)]% of
span
±0.065% of span
For spans less than 10:1,
±[0.015 + 0.005(URL / Span)]% of span
www.rosemount.com
October 2014
Rosemount 3051S Series
Process temperature RTD interface(1)
Process temperature (3051SMV_ _1 or 3)
±0.67 °F (0.37 °C)
(1) Specifications for process temperature are for the transmitter portion only. The transmitter is compatible with any Pt 100 (100 ohm platinum) RTD. Examples of
compatible RTDs include Rosemount series 68 and 78 RTD Temperature Sensors.
DP reference accuracy of 3051S ERS System(1)
2 coplanar gage transmitters (3051SAM_ _G)
Ultra
Classic
Ranges 2-4
±0.035% of DP span
±0.078% of DP span
Range 5
±0.071% of DP span
±0.092% of DP span
2 coplanar absolute transmitters (3051SAM_ _A)
Ranges 1-4
Ultra
Classic
±0.035% of DP span
±0.078% of DP span
2 In-Line gage transmitters (3051SAM_ _T)
2 In-Line absolute transmitters (3051SAM_ _E)
Ranges 1-4
Ultra
Classic
±0.035% of DP span
±0.078% of DP span
2 Liquid level transmitters (3051SAL)
Ranges 1-4
Ultra
Classic
±0.092% of DP span
±0.092% of DP span
(1) Reference Accuracy specifications for ERS system assume that the configuration contains two transmitters with identical sensor ranges, each transmitter sensor
is calibrated 0 – URL, and the DP Span = 10% of transmitter URL.
Transmitter total performance
Total performance is based on combined errors of reference accuracy, ambient temperature effect, and line pressure effect at normal
operating conditions (70% of span typical reading, 740 psi (51 bar) line pressure).
Models
3051S_CD
Ranges 2-3
3051S_CG
Ranges 2-5
3051S_CA
Ranges 2-4
3051S_T
Ranges 2-4
3051SMV(2)
Ultra
Classic and Classic MV
Ultra for Flow(1)
±0.1% of span
±0.14% of span
±0.15% of reading
For ±50 F (28 °C) temperature
changes, 0-100% relative
humidity, from 1:1 to 5:1
rangedown
For ±50 °F (28 °C) temperature
changes, 0-100% relative
humidity, over 8:1 DP
turndown from URL
DP Ranges 2-3 For ±50 °F (28 °C)
3051SAM_
Ranges 2-5 temperature changes;
0-100% relative humidity,
(3)
_G
from 1:1 to 5:1 rangedown
3051SAM_ _A(3)
Ranges 2-4
3051SAM_ _T(3)
Ranges 2-4
3051SAM_ _E(3)
Ranges 2-4
3051SAL
Use Instrument Toolkit™ or the QZ Option to quantify the total performance of a remote seal
assembly under operating conditions.
(1) Ultra for Flow is only available for 3051S_CD Ranges 2-3 and 3051SMV DP Ranges 2-4.
(2) For 3051SMV, Transmitter Total Performance specification applies to differential pressure measurement only.
(3) Specifications are for each gage / absolute pressure sensor of the ERS system and are not reflective of the DP calculation.
www.rosemount.com
109
Rosemount 3051S Series
October 2014
MultiVariable flow performance(1)
Mass, energy, actual volumetric, and totalized flow reference accuracy
Models
Ultra for Flow
Classic MV
3051SMV(2)
DP Ranges 2-3 ±0.65% of Flow Rate over a 14:1 flow range
(200:1 DP range)
DP Range 1 N/A
±0.70% of Flow Rate over 8:1 flow range
(64:1 DP range)
±0.90% of Flow Rate over 8:1 flow range
(64:1 DP range)
Annubar Flowmeter (3051SFA)
Ranges 2-3 ±0.80% of flow rate at 14:1 flow turndown
±1.15% of flow rate at 8:1 flow turndown
Compact Annubar Flowmeter (3051SFC_A)
Ranges 2-3
Standard ±1.55% of flow rate at 14:1 flow turndown
Calibrated ±0.80% of flow rate at 14:1 flow turndown
±1.60% of flow rate at 8:1 flow turndown
±1.00% of flow rate at 8:1 flow turndown
Compact Conditioning Orifice Flowmeter (3051SFC_C)
Ranges 2-3
β = 0.4 ±0.75% of flow rate at 14:1 flow turndown
β = 0.50, 0.65 ±1.15% of flow rate at 14:1 flow turndown
±1.10% of flow rate at 8:1 flow turndown
±1.45% of flow rate at 8:1 flow turndown
Compact Orifice Flowmeter(3) (3051SFC_P)
Ranges 2-3
β = 0.4 ±1.30% of flow rate at 14:1 flow turndown
β = 0.50, 0.65 ±1.30% of flow rate at 14:1 flow turndown
±1.45% of flow rate at 8:1 flow turndown
±1.45% of flow rate at 8:1 flow turndown
Integral Orifice Flowmeter (3051SFP)
Ranges 2-3
Bore < 0.160
0.160 ≤ Bore < 0.500
0.500 ≤ Bore ≤ 1.000
1.000 < Bore
±2.55% of flow rate at 14:1 flow turndown
±1.55% of flow rate at 14:1 flow turndown
±1.05% of flow rate at 14:1 flow turndown
±1.55% of flow rate at 14:1 flow turndown
±2.65% of flow rate at 8:1 flow turndown
±1.70% of flow rate at 8:1 flow turndown
±1.25% of flow rate at 8:1 flow turndown
±1.70% of flow rate at 8:1 flow turndown
(1) Flow performance specifications assume device is configured for full compensation of static pressure, process temperature, density, viscosity, gas expansion,
discharge coefficient, and thermal correction variances over a specified operating range using MultiVariable Type M or Flowmeter Measurement Types 1 through
4.
(2) Uncalibrated differential producer (0.2 < beta < 0.6 Orifice) installed per ASME MFC 3M or ISO 5167-1. Uncertainties for discharge coefficient, producer bore, tube
diameter, and gas expansion factor as defined in ASME MFC 3M or ISO 5167-1. Reference accuracy does not include RTD sensor accuracy.
(3) For line sizes less than 2-in. (50mm) or greater than 8 in. (200 mm), see the Rosemount DP Flowmeters and Primary Elements Product Data Sheet (document
number 00813-0100-4485).
110
www.rosemount.com
October 2014
Rosemount 3051S Series
Uncompensated flow performance
Flow performance specifications assume the device only uses DP readings without pressure and temperature compensation.
Models
Ultra
Classic
Ultra for Flow
±1.25% of flow rate at 8:1 flow
turndown
±0.80% of flow rate at 14:1 flow
turndown
Annubar Flowmeter (3051SFA)
Ranges 2-3 ±0.95% of flow rate at 8:1 flow
turndown
Compact Conditioning Orifice Flowmeter (3051SFC_C)
Ranges 2-3
β = 0.4 ±0.90% of flow rate at 8:1 flow
turndown
β = 0.50, 0.65 ±1.25% of flow rate at 8:1 flow
turndown
±1.10% of flow rate at 8:1 flow
turndown
±1.40% of flow rate at 8:1 flow
turndown
±0.75% of flow rate at 14:1 flow
turndown
±1.15% of flow rate at 14:1 flow
turndown
±1.70% of flow rate at 8:1 flow
turndown
±1.25% of flow rate at 8:1 flow
turndown
±1.55% of flow rate at 14:1 flow
turndown
±0.80% of flow rate at 14:1 flow
turndown
±1.80% of flow rate at 8:1 flow
turndown
±1.80% of flow rate at 8:1 flow
turndown
±1.30% of flow rate at 14:1 flow
turndown
±1.30% of flow rate at 14:1 flow
turndown
±2.70% of flow rate at 8:1 flow
turndown
±1.80% of flow rate at 8:1 flow
turndown
±1.35% of flow rate at 8:1 flow
turndown
±1.80% of flow rate at 8:1 flow
turndown
±2.60% of flow rate at 14:1 flow
turndown
±1.60% of flow rate at 14:1 flow
turndown
±1.15% of flow rate at 14:1 flow
turndown
±1.60% of flow rate at 14:1 flow
turndown
Compact Annubar Flowmeter (3051SFC_A)
Ranges 2-3
±1.65% of flow rate at 8:1 flow
turndown
±0.95% of flow rate at 8:1 flow
Calibrated
turndown
Uncalibrated
Compact Orifice Flowmeter(1) (3051SFC_P)
Ranges 2-3
β = 0.4 ±1.35% of flow rate at 8:1 flow
turndown
β = 0.50, 0.65 ±1.35% of flow rate at 8:1 flow
turndown
Integral Orifice Flowmeter (3051SFP)
Ranges 2-3
Bore < 0.160 ±2.65% of flow rate at 8:1 flow
turndown
0.160 ≤ Bore < ±1.70% of flow rate at 8:1 flow
0.500 turndown
0.500 ≤ Bore ≤ ±1.25% of flow rate at 8:1 flow
1.000 turndown
1.000 < Bore ±1.70% of flow rate at 8:1 flow
turndown
(1) For line sizes less than 2-in. (50mm) or greater than 8 in. (200 mm), see the Rosemount DP Flowmeters and Primary Elements Product Data Sheet (document
number 00813-0100-4485).
www.rosemount.com
111
Rosemount 3051S Series
October 2014
Long term stability
Pressure
Ultra and Ultra for Flow(1)
Models
Classic and Classic MV
3051S_CD
Ranges 2-5
3051S_CG
Ranges 2-5
3051S_CA
Ranges 1-4
3051S_T
Ranges 1-5
3051SAM_ _G(2)
3051SAM_ _A(2)
Ranges 2-5 ±0.15% of URL for 15 years; for ±50 °F
(28 °C) temperature changes, up to 1000 psi
Ranges 1-4 (68,95 bar) line pressure
3051SAM_ _T(2)
Ranges 1-5
3051SAM_ _E(2)
Ranges 1-5
3051SMV_ _3,4
Ranges 2-5
3051SF_ _D,3,4
Ranges 2-5
3051SMV_ _1,2
DP Ranges 2-5
3051SF_1,2
±0.20% of URL for 15 years; for
±50 °F
(28 °C) temperature changes, up to
1000 psi (68,95 bar) line pressure
±0.125% of URL for 5 years; for
±0.20% of URL for 10 years; for ±50 °F (28 °C)
±50 °F (28 °C) temperature changes,
AP & GP Ranges 3-4 temperature changes, up to 1000 psi (68,95 bar)
up to 1000 psi (68,95 bar) line
line pressure
pressure
(1) Ultra is only available for 3051S, 3051SMV_ _3 and 4, 3051SF_3, 4, 7, and D. Ultra for Flow is only available on 3051S_CD ranges 2-3, 3051SMV DP ranges 2-4,
and 3051SF DP ranges 2-3.
(2) Specifications are for each gage / absolute pressure sensor of the ERS system and are not reflective of the DP calculation.
Process temperature(1)
Models
3051SMV
3051SF
RTD Interface(1)
The greater of ±0.185 °F (0.103 °C) or 0.1% of reading per year
(excludes RTD sensor stability).
(1) Specifications for process temperature are for the transmitter portion only. The transmitter is compatible with any Pt 100 (100 ohm
platinum) RTD. Examples of compatible RTDs include the Rosemount Series 68 and 78 RTD Temperature Sensors.
Warranty(1)
Models
Ultra and Ultra for Flow
Classic and Classic MV
All 3051S Products(1)
15-year limited warranty(2)
1-year limited warranty(3)
(1) Warranty details can be found in Emerson Process Management Terms & Conditions of Sale, Document 63445, Rev G (10/06).
(2) Rosemount Ultra and Ultra for Flow transmitters have a limited warranty of fifteen (15) years from date of shipment. All other provisions of Emerson Process
Management standard limited warranty remain the same.
(3) Goods are warranted for twelve (12) months from the date of initial installation or eighteen (18) months from the date of shipment by seller, whichever period
expires first.
112
www.rosemount.com
October 2014
Rosemount 3051S Series
Dynamic performance
Total time response at 75 °F (24 °C), includes dead time(1)(2)
3051S_C
3051SF_D
DP Ranges 2-5: 100 ms
Range 1: 255 ms
Range 0: 700 ms
3051S_T
3051SMV_ _1 or 2
3051SF_1, 2, 5, or 6
3051SMV_ _3 or 4
3051SF_3, 4, or 7
ERS System
(3051SAM)
100 ms
DP Range 1: 310 ms
DP Range 2: 170 ms
DP Range 3: 155 ms
AP & GP: 240 ms
DP Ranges 2-5: 145 ms
DP Range 1: 300 ms
DP Range 0: 745 ms
360 ms
(1) For FOUNDATION fieldbus (output code F), add 52 ms to stated values (not including segment macro-cycle).
For option code DA2, add 45 ms (nominal) to stated values.
(2) Consult Instrument Toolkit for transmitter configurations with remote seals including 3051SAL.
Dead time(1)
3051S_C
3051S_T
3051SF_D
3051SAL_C
3051SMV
3051SF_1-7
ERS System (includes
3051SAM,
3051SAL_P, and
3051SAL_S models)
45 ms (nominal)
DP: 100 ms
AP & GP: 140 ms
RTD Interface: 1 s
220 ms
(1) For option code DA2, dead time is 90 milliseconds (nominal).
Sensor update rate(1)
3051S_C or T
3051SF_D
3051SAL_C
3051SMV
3051SF_1-7
22 updates per
sec.
DP: 22 updates per sec.
AP & GP: 11 updates per sec.
RTD Interface: 1 update per
sec.
ERS System (includes
3051SAM, 3051SAL_P,
and 3051SAL_S models)
Calculated Variables:
Mass / Volumetric Flow Rate: 22 updates per
sec.
Energy Flow Rate: 22 updates per sec.
Totalized Flow: 1 update per sec.
11 updates per sec.
(1) Does not apply to Wireless (output code X). See“IEC 62591 (WirelessHART)” on page 123 for wireless update rate.
www.rosemount.com
113
Rosemount 3051S Series
October 2014
Ambient temperature effect
Transmitter with coplanar sensor module (single variable)
Differential pressure: (3051S_CD, 3051SMV_ _3 or 4)
Gage pressure: (3051S_CG, 3051SAM_ _G(1))
Ultra
per 50 °F (28 °C)
Classic
per 50 °F (28 °C)
Ultra for Flow(2)
-40 to 185 °F (-40 to 85 °C)
Ranges 2 - 5(3)
±(0.009% URL + 0.025% span)
from 1:1 to 10:1;
±(0.018% URL + 0.08% span) from
>10:1 to 200:1
±(0.0125% URL +0.0625% span)
from 1:1 to 5:1;
±(0.025% URL + 0.125% span)
from >5:1 to 150:1
±0.13% of reading up to 8:1 DP turndown
from URL;
±[0.13 + 0.0187(URL/Reading)]% of
reading to 100:1 DP turndown from URL
Range 0
±(0.25% URL + 0.05% span) from
1:1 to 30:1
±(0.25% URL + 0.05% span)
from 1:1 to 30:1
N/A
Range 1
±(0.1% URL + 0.25% span)
from 1:1 to 50:1
±(0.1% URL + 0.25% span)
from 1:1 to 50:1
N/A
Absolute pressure: (3051S_CA, 3051SAM_ _A(1))
Ultra
per 50 °F (28 °C)
Classic
per 50 °F (28 °C)
Ranges 2-4
±(0.0125% URL + 0.0625% span)
from 1:1 to 5:1;
±(0.025% URL + 0.125% span)
from >5:1 to 200:1
±(0.0125% URL + 0.0625% span) from 1:1 to
5:1;
±(0.025% URL + 0.125% span) from >5:1 to
150:1
Range 0
±(0.1% URL + 0.25% span)
from 1:1 to 30:1
±(0.1% URL + 0.25% span) from 1:1 to 30:1
Range 1
±(0.0125% URL + 0.0625% span)
from 1:1 to 5:1;
±(0.025% URL + 0.125% span)
from >5:1 to 100:1
±(0.0125% URL + 0.0625% span) from 1:1 to
5:1;
±(0.025% URL + 0.125% span) from >5:1 to
100:1
(1) Specifications are for each gage/absolute pressure sensor of the ERS system and are not reflective of the DP calculation.
(2) Ultra for Flow is only available for 3051S_CD Ranges 2-3 and 3051SMV DP Ranges 2-3.
(3) Use Classic specification for 3051SMV DP Range 5 Ultra and 3051S_CD Range 5 Ultra.
Transmitter with in-line sensor module
Absolute pressure: (3051S_TA, 3051SAM_ _E(1))
Gage pressure: (3051S_TG, 3051SAM_ _T(1))
Ultra
per 50 °F (28 °C)
Classic
per 50 °F (28 °C)
Ranges 2-4
±(0.009% URL + 0.025% span) from 1:1 to 10:1;
±(0.018% URL + 0.08% span) from >10:1 to 200:1
±(0.0125% URL + 0.0625% span)
from 1:1 to 5:1;
±(0.025% URL + 0.125% span)
from >5:1 to 150:1
Range 5
±(0.05% URL + 0.075% span) from 1:1 to 10:1
±(0.05% URL + 0.075% span)
from 1:1 to 10:1
Range 1
±(0.0125% URL + 0.0625% span) from 1:1 to 5:1;
±(0.025% URL + 0.125% span) from >5:1 to 100:1
±(0.0125% URL + 0.0625% span)
from 1:1 to 5:1;
±(0.025% URL + 0.125% span)
from >5:1 to 100:1
(1) Specifications are for each gage/absolute pressure sensor of the ERS system and are not reflective of the DP calculation.
114
www.rosemount.com
October 2014
Rosemount 3051S Series
Transmitter with multivariable sensor module
Differential pressure and static pressure (3051SMV_ _1 or 2)
Models
DP Ranges 2-3
DP Range 4
DP Range 5
DP Range 1
AP & GP
Classic MV
Per 50 °F (28 °C)
±(0.0125% URL + 0.0625% span)
from 1:1 to 5:1;
±(0.025% URL + 0.125% span) for >5:1 to
100:1
±(0.025% URL + 0.125% span) from 1:1 to
30:1
±(0.035% URL + 0.125% span) from 30:1 to
100:1
±(0.025% URL + 0.125% span) from 1:1 to
30:1
±(0.035% URL + 0.125% span) from 30:1 to
100:1
±(0.1% URL + 0.25% span)
from 1:1 to 50:1
±(0.0125% URL + 0.0625% span)
from 1:1 to 10:1;
±(0.025% URL + 0.125% span) for >10:1 to
100:1
Ultra for Flow
-40 to 185 °F (-40 to 85 °C)
±0.13 reading up to 8:1 DP turndown from URL;
±[0.13 + 0.0187(URL/Reading)]% reading to 100:1 DP turndown
from URL
±0.130% of reading less than or equal to 3:1
±[0.050 + 0.065 (URL/RDG)]% of reading greater than 3:1
N/A
Not available
±(0.009% URL + 0.025% span)
from 1:1 to 10:1;
±(0.018% URL + 0.08% span) for >10:1(1)
(1) For DP range 4 or 5, Ultra for Flow ambient temperature effect on static pressure is +/-(0.0125% URL + 0.0625% Span) from 1:1 to 10:1; +/-(0.025% URL + 0.125%
Span) for >10:1.
Liquid level transmitter
3051SAL
Ultra
Classic
See Instrument Toolkit.
See Instrument Toolkit.
Process temperature RTD interface(1)
Process temperature (3051SMV_ _1 or 3)
Classic MV
Per 50 °F (28 °C)(1)
Ultra for Flow
-40 to 185 °F (-40 to 85 °C)
±0.39 °F (0,216 °C) per 50 °F (28 °C)
±0.39 °F (0,216 °C) per 50 °F (28 °C)
(1) Specifications for process temperature are for the transmitter portion only. The transmitter is compatible with any Pt 100 (100 ohm platinum) RTD. Examples of
compatible RTDs include Rosemount series 68 and 78 RTD Temperature Sensors.
www.rosemount.com
115
Rosemount 3051S Series
October 2014
Line pressure effect(1)
3051S_CD
3051SMV (DP Measurement
Only)
Ultra and Ultra for Flow
Classic and Classic MV
Zero Error(2)
Range 2-3 ± 0.025% URL per 1000 psi (68,95 bar)
± 0.05% URL per 1000 psi (68,95 bar)
Range 0 ± 0.125% URL per 100 psi (6,89 bar)
± 0.125% URL per 100 psi (6,89 bar)
Range 1 ± 0.25% URL per 1000 psi (68,95 bar)
± 0.25% URL per 1000 psi (68,95 bar)
Span Error(3)
Range 2-3 ± 0.1% of reading per 1000 psi (68,95 bar) ± 0.1% of reading per 1000 psi (68,95 bar)
Range 0 ± 0.15% of reading per 100 psi (6,89 bar)
± 0.15% of reading per 100 psi (6,89 bar)
Range 1 ± 0.4% of reading per 1000 psi (68,95 bar) ± 0.4% of reading per 1000 psi (68,95 bar)
(1) For zero error specifications for line pressures above 2000 psi (137,89 bar) or line pressure effect specifications for DP Ranges 4-5, see the 3051SMV Reference
Manual (document number 00809-0100-4803) or 3051S Reference Manual (document number 00809-0100-4801).
(2) Zero error can be removed by performing a zero trim at line pressure.
(3) Specifications for option code P0 are 2 times those shown above.
Mounting position effects
Models
Ultra, Ultra for Flow, Classic and Classic MV
3051S_CD or CG
3051SMV_ _ 3 or 4
3051SF_3, 4, 7, or D
3051SAM_ _G
3051S_CA
3051S_T
3051SAM_ _A, T, or E
3051SMV_ _ 1 or 2
3051SF_1, 2, 5, or 6
3051SAL
Zero shifts up to ±1.25 inH2O (3,11 mbar), which can be zeroed
Span: no effect
Zero shifts to ±2.5 inH2O (6,22 mbar), which can be zeroed
Span: no effect
DP Sensor: Zero shifts up to ±1.25 inH2O (3,11 mbar), which can be zeroed
Span: no effect
GP/AP Zero shifts to ±2.5 inH2O (6,22 mbar), which can be zeroed
Sensor: Span: no effect
With liquid level diaphragm in vertical plane, zero shift of up to ±1 inH2O (2,49 mbar). With
diaphragm in vertical plane, zero shift of up to ±5 inH2O (12,43 mbar) plus extension length on
extended units. All zero shifts can be zeroed.
Span: no effect
Vibration effect
Less than ±0.1% of URL when tested per the requirements of IEC60770-1 field or pipeline with high vibration level (10-60 Hz 0.21 mm
displacement peak amplitude / 60-2000 Hz 3g).
For Housing Style codes 1J, 1K, 1L, 2J, and 2M:
Less than ±0.1% of URL when tested per the requirements of IEC60770-1 field with general application or pipeline with low vibration
level (10-60 Hz 0.15 mm displacement peak amplitude / 60-500 Hz 2g).
Power supply effect
Less than ±0.005% of calibrated span per volt change in voltage at the transmitter terminals
116
www.rosemount.com
October 2014
Rosemount 3051S Series
Electromagnetic compatibility (EMC)
Meets all relevant requirements of EN 61326 and NAMUR
NE-21.(1)(2)
(1)
NAMUR NE-21 does not apply to wireless output code X or ERS configurations.
(2)
3051SMV and 3051SF_1, 2, 3, 4, 5, 6, 7 requires shielded cable for both
temperature and loop wiring.
Transient protection (option T1)
Tested in accordance with IEEE C62.41.2-2002, Location
Category B
• 6 kV crest (0.5 μs - 100 kHz)
• 3 kA crest (8 × 20 microseconds)
• 6 kV crest (1.2 × 50 microseconds)
www.rosemount.com
117
Rosemount 3051S Series
October 2014
Functional specifications
Range and sensor limits
Transmitter with coplanar sensor module (single variable)
DP Sensor(1)
(3051S_CD, 3051SMV_ _3, 4,
or D 3051SF_3, 4, or 7,
Range
3051SAL_CD)
AP Sensor(2)
(3051S_CA, 3051SAM_ _A,
3051SAL_ _A)
GP Sensor
(3051S_CG, 3051SAM_ _G,
3051SAL_ _G)
Lower (LRL)(3)
Upper (URL)
Lower (LRL)(4)
Upper (URL)
Lower (LRL)
Upper (URL)
0
-3.00 inH2O
(-7,45 mbar)
3.00 inH2O
(7,45 mbar)
N/A
N/A
0 psia
(0 bar)
5.00 psia
(0,34 bar)
1
-25.00 inH2O
(-62,16 mbar)
25.00 inH2O
(62,16 mbar)
-25.00 inH2O
(-62,16 mbar)
25.00 inH2O
(62,16 mbar)
0 psia
(0 bar)
30.00 psia
(2,06 bar)
2
-250.00 inH2O
(-621,60
mbar)
250.00 inH2O
(621,60 mbar)
-250.00 inH2O
(-621,60 mbar)
250.00 inH2O
(621,60 mbar)
0 psia
(0 bar)
150.00 psia
(10,34 bar)
3
-1000.00
inH2O
(-2,48 bar)
1000.00 inH2O
(2,48 bar)
0.50 psia
(34,47 mbar)
1000.00 inH2O
(2,48 bar)
0 psia
(0 bar)
800.00 psia
(55,15 bar)
4
-300.00 psi
(-20,68 bar)
300.00 psi
(20,68 bar)
0.50 psia
(34,47 mbar)
300.00 psi
(20,68 bar)
0 psia
(0 bar)
4000.00 psia
(275,79 bar)
5
-2000.00 psi
(-137,89 bar)
2000.00 psi
(137,89 bar)
0.50 psia
(34,47 mbar)
2000.00 psi
(137,89 bar)
N/A
N/A
(1) 3051SF Flowmeters only available with ranges 1, 2, and 3.
(2) Range 0 is not available for 3051SAL_ _A.
(3) The Lower Range Limit (LRL) is 0 inH20 (0 mbar) for Ultra for Flow Performance Class and 3051SF flowmeters.
(4) Assumes atmospheric pressure of 14.7 psia (1 bar-a).
Transmitter with in-line sensor module
Range
GP Sensor
(3051S_TG, 3051SAM_ _T, 3051SAL_ _T)
AP Sensor
(3051S_TA, 3051SAM_ _E, 3051SAL_ _E)
Lower (LRL)(1)
Upper (URL)
Lower (LRL)
Upper (URL)
1
-14.70 psig (-1,01 bar)
30.00 psig (2,06 bar)
0 psia (0 bar)
30.00 psia (2,06 bar)
2
-14.70 psig (-1,01 bar)
150.00 psig (10,34 bar)
0 psia (0 bar)
150.00 psia (10,34 bar)
3
-14.70 psig (-1,01 bar)
800.00 psig (55,15 bar)
0 psia (0 bar)
800.00psia (55,15 bar)
4
-14.70 psig (-1,01 bar)
4000.00 psig (275,79 bar)
0 psia (0 bar)
4000.00 psia (275,79 bar)
5
-14.70 psig (-1,01 bar)
10000.00 psig (689,47 bar)
0 psia (0 bar)
10000.00 psia (689,47 bar)
(1) Assumes atmospheric pressure of 14.7 psia (1 bar-a).
118
www.rosemount.com
October 2014
Rosemount 3051S Series
Transmitter with multivariable sensor module
(3051SMV_ _1, 3051SMV_ _2, 3051SF_1, 3051SF_2, 3051SF_5, and 3051SF_6)
DP Sensor
Range
Lower (LRL)(1)
Upper (URL)
1
25.00 inH2O (-62,16 mbar)
25.00 inH2O (62,16 mbar)
2
-250.00 inH2O (-621,60 mbar)
250.00 inH2O (621,60 mbar)
3
1000.00 inH2O (-2,48 bar)
1000.00 inH2O (2,48 bar)
4
150.00 psi (-10,34 bar)
150.00 psi (10,34 bar)
5
-2000.00 psi (137,89 bar)
2000.00 psi (137,89 bar)
(1) Lower (LRL) is 0 inH2O (0 mbar) for Ultra for Flow and 3051SF_ Flowmeters.
Static pressure sensor (GP/AP)
Range
Lower (LRL)
Upper (URL)(1)
3
GP(2)(3): 14.20 psig (0,97 bar)
AP: 0.5 psia (34,47 mbar)
GP: 800.00 psig (55,15 bar)
AP: 800.00 psia (55,15 bar)
4
GP(2)(3): 14.20 psig (0,97 bar)
AP: 0.50 psia (34,47 mbar)
GP: 3626.00 psig (250,00 bar)
AP: 3626.00 psia (250,00 bar)
(1) For SP Range 4 with DP Range 1, the URL is 2000 psi (137,9 bar).
(2) Inert Fill: Minimum pressure = 1.5 psia (0,10 bar) or -13.2 psig (-0,91 bar).
(3) Assumes atmospheric pressure of 14.7 psia (1 bar-a).
Process temperature RTD Interface
(3051SMV_ _1 or 3, 3051SF_1, 3, 5 or 7)(1)
Lower (LRL)
Upper (URL)
-328 °F (-200 °C)
1562 °F (850 °C)
(1) Transmitter is compatible with any Pt 100 RTD sensor. Examples of compatible RTDs include Rosemount Series 68 and 78 RTD Temperature Sensors.
www.rosemount.com
119
Rosemount 3051S Series
October 2014
Minimum span limits
Transmitter with coplanar sensor module (single variable)
DP Sensor(1)
GP Sensor
(3051S_CG, 3051SAM_ _G(3),
(3051S_CD, 3051SMV_ _3 or 4,
(2)
3051SAL_ _G(2)(3))
Range 3051SF_D, 3, 4 or 7, 3051SAL_ _CD )
AP Sensor
(3051S_CA, 3051SAM_ _A(3),
3051SAL_ _A(2)(3))
Ultra &
Ultra for Flow
Classic
Ultra
Classic
Ultra
Classic
0
0.10 inH2O
(0,24 mbar)
0.10 inH2O
(0,24 mbar)
N/A
N/A
0.167 psia
(11,51 mbar)
0.167 psia
(11,51 mbar)
1
0.50 inH2O
(1,24 mbar)
0.50 inH2O
(1,24 mbar)
0.50 inH2O
(1,24 mbar)
0.50 inH2O
(1,24 mbar)
0.30 psia
(20,68 mbar)
0.30 psia
(20,68 mbar)
2
1.25 inH2O
(3,11 mbar)
1.67 inH2O
(4,15 mbar)
1.25 inH2O
(3,11 mbar)
1.67 inH2O
(4,15 mbar)
0.75 psia
(51,71 mbar)
1.00 psia
(68,94 mbar)
3
5.00 inH2O
(12,43 mbar)
6.67 inH2O
(16,58 mbar)
5.00 inH2O
(12,43 mbar)
6.67 inH2O
(16,58 mbar)
4.00 psia
(275,79 mbar)
5.33 psia
(367,49 mbar)
4
1.50 psi
(103,42 mbar)
2.00 psi
(137,89 mbar)
1.50 psig
(103,42 mbar)
2.00 psig
(137,89 mbar)
20.00 psia
(1,38 bar)
26.67 psia
(1,83 bar)
5
10.00 psi
(689,48 mbar)
13.33 psi
(919,01 bar)
10.00 psig
(689,48 mbar)
13.33 psig
(919,01 bar)
N/A
N/A
(1) 3051SF flowmeters only available with ranges 1, 2, and 3.
(2) For 3051SAL models, use Classic minimum span limits.
(3) Specifications are for each gage/absolute pressure sensor of the ERS system and are not reflective of the DP calculation.
Transmitter with in-line sensor module
Rang
e
GP Sensor
(3051S_TG, 3051SAM_ _T(1), 3051SAL_ _T(2))
AP Sensor
(3051S_TA, 3051SAM_ _E(1), 3051SAL_ _E(2))
Ultra
Classic
Ultra
Classic
1
0.30 psig (20,68 mbar)
0.30 psig (20,68 mbar)
0.30 psia (20,68 mbar)
0.30 psia (20,68 mbar)
2
0.75 psig (51,71 mbar)
1.00 psig (68,94 mbar)
0.75 psia (51,71 mbar)
1.00 psia (68,94 mbar)
3
4.00 psig (275,79 mbar)
5.33 psig (367,49 mbar)
4.00 psia (275,79 mbar)
5.33 psia (367,49 mbar)
4
20.00 psig (1,38 bar)
26.67 psig (1,83 bar)
20.00 psia (1,38 bar)
26.67 psia (1,83 bar)
5
1000.00 psig (68,95 bar)
2000.00 psig (137,89 bar)
1000.00 psia (68,95 bar)
2000.00 psia (137,89 bar)
(1) Specifications are for each gage/absolute pressure sensor of the ERS system and are not reflective of the DP calculation.
(2) For 3051SAL models, use Classic minimum span limits.
120
www.rosemount.com
October 2014
Rosemount 3051S Series
Transmitter with multivariable sensor module
(3051SMV_ _1 or 2, 3051SF_1, 2, 5, or 6)
DP Sensor
Range
1
2
3
4
5
Ultra for Flow
Classic MV
0.5 inH2O (1,24 mbar)
1.3 inH2O (3,23 mbar)
5.0 inH2O (12,43 mbar)
1.5 psi (103,42 mbar)
N/A
0.5 inH2O (1,24 mbar)
2.5 inH2O (6,22 mbar)
10.0 inH2O (24,86 mbar)
3.0 psi (206,84 mbar)
20.0 psi (1,38 bar)
Static pressure sensor (GP/AP)
Range
3
4
Ultra for Flow
Classic MV
4.0 psi (275,79 mbar)
18.13 psi (1,25 bar)
8.0 psi (551,58 mbar)
36.26 psi (2,50 bar)
Process temperature RTD Interface
(3051SMV_ _1 or 3, 3051SF_1, 3, 5 or 7)
Minimum Span = 52 °F (11 °C)
DP span considerations for electronic remote sensor applications
It is recommended that the DP rangedown (Operating
Pressure/DP Span) for ERS applications not exceed 100:1.
Consult with your Emerson Process Management sales
representative when considering a 3051S ERS System for
applications beyond 100:1 rangedown.
Service
3051S, 3051SMV_P, 3051SAM, and 3051SF_5, 6, 7, or D (direct process variable output):
Liquid, gas, and vapor applications
3051SAL
Liquid level applications
3051SMV_M and 3051SF_1, 2, 3, or 4 (mass and energy flow output):
Some fluid types are only supported by certain measurement types.
Table 19. Fluid Compatibility with Pressure and Temperature Compensation
• Available
Ordering
code
— Not available
Fluid types
Measurement type
Liquids
Saturated steam Superheated steam Gas and natural gas
1
DP / P/ T (Full Compensation)
•
•
•
•
2
DP / P
•
•
•
•
3
DP / T
•
•
—
—
4
DP only
•
•
—
—
www.rosemount.com
121
Rosemount 3051S Series
October 2014
4–20 mA HART
Zero and span adjustment
Zero and span values can be set anywhere within the range.
Span must be greater than or equal to the minimum span.
3051S ERS System
If supply voltage ≤ 16.74 Vdc:
Maximum Loop Resistance = 277 * (Power Supply Voltage – 16.0)
If supply voltage > 16.74 Vdc:
Maximum Loop Resistance = 43.5 * (Power Supply Voltage – 12.0)
Output
Two-wire 4–20 mA is user-selectable for linear or square root
output. Digital process variable superimposed on 4–20 mA
signal, available to any host that conforms to the HART
protocol.
Load limitations
Maximum loop resistance is determined by the voltage level
of the external power supply, as described by:
3051S and 3051SF_D
Maximum Loop Resistance = 43.5 * (Power Supply Voltage – 10.5)
Load (Ohms)
1387
1000
500
Operating
Region
0
10.5
20
30
Voltage (Vdc)
42.4
The Field Communicator requires a minimum
loop resistance of 250Ω for communication.
Load (Ohms)
Power supply
External power supply required.
•3051S and 3051SF_D: 10.5 to 42.4 Vdc with no load
•3051S and 3051SF_D with Advanced HART Diagnostics
Suite: 12 to 42.4 Vdc with no load
•3051SMV and 3051SF_1-7: 12 to 42.4 Vdc with no load
•3051S ERS System: 16.0 to 42.4 Vdc with no load
1322
Operating
Region
206
0
16 16.74
42.4
Voltage (Vdc)
The Field Communicator requires a minimum
loop resistance of 250Ω for communication.
Advanced HART Diagnostics Suite
(option code DA2)
Statistical Process Monitoring (SPM) provides statistical data
(standard deviation, mean, coefficient of variation) that can
be used to detect process and process equipment
anomalies, including plugged impulse lines, air entrainment,
pump cavitation, furnace flame instability, distillation
column flooding and more. This diagnostic allows you to
take preventative measures before abnormal process
situations result in unscheduled downtime or rework.
Power Advisory diagnostic pro-actively detects and notifies
you of degraded electrical loop integrity before it can affect
your process operation. Example loop problems that can be
detected include water in the terminal compartment,
corrosion of terminals, improper grounding, and unstable
power supplies.
The Device Dashboard presents the diagnostics in a
graphical, task-based interface that provides single click
access to critical process/device information and descriptive
graphical troubleshooting.
3051SMV and 3051SF_1-7
3051S and 3051SF_D with HART Diagnostics
(option code DA2)
Maximum Loop Resistance = 43.5 * (Power Supply Voltage – 12.0)
Suite includes: Statistical Process Monitoring (SPM), Power
Advisory, Status Log, Variable Log, Advanced Process Alerts,
Service Alerts, and Time Stamp capability.
FOUNDATION fieldbus
Power supply
Load (Ohms)
1322
External power supply required; transmitters operate on
9.0 to 32.0 Vdc transmitter terminal voltage.
1000
Current draw
500
17.5 mA for all configurations (including LCD display option)
Operating
Region
FOUNDATION fieldbus parameters
0
12.0
20
30
Voltage (Vdc)
The Field Communicator requires a minimum
loop resistance of 250Ω for communication.
122
Schedule Entries
42.4
Links
Virtual Communications Relationships
(VCR)
14
(max.)
30
(max.)
20
(max.)
www.rosemount.com
October 2014
Rosemount 3051S Series
Standard function blocks
Resource block
• Contains hardware, electronics, and diagnostic information.
Transducer block
• Contains actual sensor measurement data including the sensor
diagnostics and the ability to trim the pressure sensor or recall
factory defaults.
LCD display block
• Configures the local display.
2 analog input blocks
• Processes the measurements for input into other function blocks.
The output value is in engineering or custom units and contains a
status indicating measurement quality.
PID block with auto-tune
• Contains all logic to perform PID control in the field including
cascade and feedforward. Auto-tune capability allows for superior
tuning for optimized control performance.
Backup link active scheduler (LAS)
The transmitter can function as a Link Active Scheduler if the
current link master device fails or is removed from the
segment.
Software upgrade in the Field
Software for the 3051S with FOUNDATION fieldbus is easy to
upgrade in the field using the FOUNDATION fieldbus Common
Device Software Download procedure.
PlantWeb alerts
Enable the full power of the PlantWeb digital architecture by
diagnosing instrumentation issues, communicating
advisory, maintenance, and failure details, and
recommending a solution.
Advanced Control Function Block Suite
(option code A01)
Input Selector Block
• Selects between inputs and generates an output using specific
selection strategies such as minimum, maximum, midpoint,
average, or first “good.”
Arithmetic Block
• Provides pre-defined application-based equations including flow
with partial density compensation, electronic remote sensors,
hydrostatic tank gauging, ratio control and others.
Signal Characterizer Block
• Characterizes or approximates any function that defines an
input/output relationship by configuring up to twenty X, Y
coordinates. The block interpolates an output value for a given input
value using the curve defined by the configured coordinates.
Integrator Block
• Compares the integrated or accumulated value from one or two
variables to pre-trip and trip limits and generates discrete output
signals when the limits are reached. This block is useful for
calculating total flow, total mass, or volume over time.
Output Splitter Block
• Splits the output of one PID or other control block so that the PID
will control two valves or other actuators.
Control Selector Block
• Selects one of up to three inputs (highest, middle, or lowest) that
are normally connected to the outputs of PID or other control
function blocks.
Block
Execution time
Resource
Transducer
LCD Display Block
Analog Input 1, 2
PID with Auto-tune
Input Selector
Arithmetic
Signal Characterizer
Integrator
Output Splitter
Control Selector
N/A
N/A
N/A
20 milliseconds
35 milliseconds
20 milliseconds
20 milliseconds
20 milliseconds
20 milliseconds
20 milliseconds
20 milliseconds
Fully compensated mass flow block (option code H01)
Calculates fully compensated mass flow based on differential
pressure with external process pressure and temperature
measurements over the fieldbus segment. Configuration for
the mass flow calculation is easily accomplished using the
Rosemount Engineering Assistant 5.5.1 software.
FOUNDATION fieldbus Diagnostics Suite
(option code D01)
Statistical Process Monitoring (SPM) provides statistical data
(standard deviation and mean) that can be used to detect
process and process equipment anomalies, including
plugged impulse lines, air entrainment, pump cavitation,
furnace flame instability, distillation column flooding, and
more. This diagnostic allows you to take preventative
measures before abnormal process situations result in
unscheduled downtime or rework.
The Device Dashboard presents the diagnostics in a
graphical, task-based interface that provides single click
access to critical process/device information and descriptive
graphical troubleshooting.
Suite includes: Statistical Process Monitoring (SPM) and
Plugged Impulse Line Detection (PIL).
IEC 62591 (WirelessHART)
Output
IEC 62591 (WirelessHART), 2.4 GHz DSSS
Radio frequency power output from antenna
External Antenna (WK option): Maximum of 10 mW
(10 dBm) EIRP
Extended Range, External Antenna (WM option): Maximum
of 18 mW (12.5 dBm) EIRP
Remote (WJ option) antenna: Maximum of 17 mW (12.3
dBm) EIRP
High-Gain, Remote Antenna (WN option): Maximum of 40
mW (16 dBm) EIRP
Local display
The optional seven-digit LCD display can display
user-selectable information such as primary variable in
engineering units, percent of range, sensor module
temperature, and electronics temperature. The display
updates based on the wireless update rate.
Update rate
User selectable 1 sec. to 60 min.
www.rosemount.com
123
Rosemount 3051S Series
October 2014
Power module
Liquid level transmitter (3051SAL)
Field replaceable, keyed connection eliminates the risk of
incorrect installation, Intrinsically Safe Lithium-thionyl
chloride Power Module with polybutadine terephthalate
(PBT) enclosure. Ten-year life at one minute update
rate.(1)(2)
(1) Reference conditions are 70 °F (21 °C), and routing data for three
additional network devices.
Note: Continuous exposure to ambient temperature limits of
-40 °F or 185 °F (-40 °C or 85 °C) may reduce specified life by less than
20 percent.
Overpressure limit is dependent on the flange rating or sensor
rating (whichever is lower). Use Instrument Toolkit to ensure the
seal system meets all pressure and temperature limits.
Static pressure limits
Coplanar sensor module (single variable)
Operates within specifications between static line pressures of:
DP Sensor(1)
Range
3051S_CD
3051SMV_ _3 or 4
3051SF_3, 4, 7, or D
0
1
2
3
4
5
0.5 psia to 750 psig (0,03 to 51,71 bar)
0.5 psia to 2000 psig (0,03 to 137,90 bar)
0.5 psia to 3626 psig (0,03 to 250,00 bar)
0.5 psia to 3626 psig (0,03 to 250,00 bar)
0.5 psia to 3626 psig (0,03 to 250,00 bar)
0.5 psia to 3626 psig (0,03 to 250,00 bar)
(2) 6.5-year life at one minute update rates when used with 3051SMV.
Overpressure limits
Transmitters withstand the following limits without damage:
Coplanar sensor module (single variable)
DP(1) & GP
3051S_CD,
3051S_CG
Range
3051SMV_ _3 or 4
3051SF_3, 4, 7, or D
3051SAM_ _G
0
1
2
3
4
5
750 psi (51,71 bar)
2000 psi (137,90 bar)
3626 psi (250,00 bar)
3626 psi (250,00 bar)
3626 psi (250,00 bar)
3626 psi (250,00 bar)
AP
3051S_CA
3051SAM_ _A
60 psia (4,14 bar)
750 psia (51,71 bar)
1500 psia (103,42 bar)
1600 psia (110,32 bar)
6000 psia (413,69 bar)
N/A
(1) The overpressure limit of a DP Sensor with the P9 option is 4500 psig
(310,3 bar). The overpressure limit of a DP Sensor with the P0 option
is 6092 psig (420 bar).
In-line sensor module
Range
GP
AP
3051S_TG
3051SAM_ _T
3051S_TA
3051SAM_ _E
1
2
3
4
5
750 psi (51,71 bar)
1500 psi (103,42 bar)
1600 psi (110,32 bar)
6000 psi (413,69 bar)
15000 psi (1034,21 bar)
Coplanar multivariable sensor module (3051SMV_ _1 or 2,
3051SF_1, 2, 5, or 6)
DP
Range
1
2
3
4
5
124
Static pressure range (GP/AP)
3
4
1600 psi (110,32 bar)
1600 psi (110,32 bar)
1600 psi (110,32 bar)
N/A
N/A
2000 psi (137,90 bar)
3626 psi (250,00 bar)
3626 psi (250,00 bar)
3626 psi (250,00 bar)
3626 psi (250,00 bar)
(1) The static pressure limit of a DP Sensor with the P9 option is 4500
psig (310,26 bar). The static pressure limit of a DP Sensor with the P0
option is 6092 psig (420,00 bar).
Coplanar multivariable sensor module (3051SMV_ _1 or 2,
3051SF_1, 2, 5, or 6)
Operates within specifications between static line pressures of
0.5 psia (0,03 bar) and the values in the table below:
DP
Range
Static pressure range (GP/AP)
3
4
1
800 psi (55,15 bar)
2000 psi (137,90 bar)
2
800 psi (55,15 bar)
3626 psi (250,00 bar)
3
800 psi (55,15 bar)
3626 psi (250,00 bar)
4
N/A
3626 psi (250,00 bar)
5
N/A
3626 psi (250,00 bar)
Maximum working pressure limits
Maximum working pressure is the maximum pressure allowed
for normal transmitter operation. For a differential pressure
transmitter, the maximum working pressure is the static line
pressure under which the transmitter can safely operate. If one
side of the transmitter is exposed to the full static line pressure
due to mis-valving, the transmitter will experience an output
shift and must be re-zeroed. For a gage or absolute pressure
transmitter, the maximum working pressure is the same as the
Upper Range Limit (URL). The maximum working pressure of
transmitters with assemble-to options is limited by the lowest
maximum pressure rating of the individual components.
www.rosemount.com
October 2014
Rosemount 3051S Series
Table 20. 3051S Maximum Working Pressure
Range
3051S_CD
3051SAL_ _D
3051SAM_ _D
3051S_CG
3051SAL_ _G
3051SAM_ G
3051S_CA
3051SAL_ _A
3051SAM_ _A
3051S_TA
3051SAL_ _E
3051SAM_ _E
3051S_TG
3051SAL_ _T
3051SAM_ _T
0
750 psi
51.7 bar
5.17 mpa
N/A
5 psia
0.35 bar-a
.035 mpa
N/A
N/A
1
2000 psi
138 bar
13.8 mpa
0.9 psi
0.062 bar
0.0062 mpa
30 psia
2.07 bar-a
0.207 mpa
30 psia
2.07 bar-a
0.207 mpa
30 psia
2.07 bar-a
0.207 mpa
2
3626 psi
250 bar
25 mpa
9 psi
0.62 bar
0.062 mpa
150 psia
10.3 bar
1.03 mpa
150 psia
10.3 bar-a
1.03 mpa
150 psi
10.3 bar
1.03 mpa
3
3626 psi
250 bar
25 mpa
36 psi
2.48 bar
0.248 mpa
800 psia
55.2 bar-a
5.52 mpa
800 psia
55.2 bar-a
5.52 mpa
800 psia
55.2 bar
5.52 mpa
4
3626 psi
250 bar
25 mpa
300 psi
20.7 bar
2.07 mpa
4000 psia
276 bar-a
27.6 mpa
4000 psia
276 bar-a
27.6 mpa
4000 psia
276 ba
27.6 mpa
5
3626 psi
250 bar
25 mpa
2000 psi
138 bar
13.8 mpa
N/A
10000psia
690 bar-a
69.0 mpa
10000psia
690 bar
69.0 mpa
Note
The maximum working pressure limit of a DP Sensor with the P9 option is 4500 psig (310,26 bar). The maximum working pressure
limit of a DP Sensor with the P0 option is 6092 psig (420,00 bar).
Table 21. 3051SMV maximum working pressure
(3051SMV1M1[X]G[Y]R2E12A1A)
X = DP
Range
Y = 3 (DP/AP
Range)
Y = 4 (GP/AP
Range)
1
800 psi
55.2 bar
5.52 mpa
2000 psi
138 bar
13.8 mpa
2
800 psi
55.2 bar
5.52 mpa
3626 psi
250 bar
25 mpa
3
800 psi
55.2 bar
5.52 mpa
3626 psi
250 bar
25 mpa
Temperature limits
Ambient
-40 to 185 °F (-40 to 85 °C)
With LCD display(1): -40 to 175 °F (-40 to 80 °C)
With option code P0: -20 to 185 °F (-29 to 85 °C)
(1)
LCD display may not be readable and LCD display updates will be
slower at temperatures below -4 °F (-20 °C).
Storage
-50 to 185 °F (-46 to 85 °C)
With LCD display: -40 to 185 °F (-40 to 85 °C)
With Wireless Output: -40 to 185 °F (-40 to 85 °C)
Process temperature limits
At atmospheric pressures and above:(8)
Burst pressure limits
Coplanar sensor module
(3051S_C, 3051SMV, 3051SF, 3051SAM_ _G or A)
10000 psig (689,47 bar)
In-line sensor module
(3051S_T, 3051SAM_ _T or E)
• Ranges 1-4: 11000 psi (758,42 bar)
• Range 5: 26000 psi (1792,64 bar)
www.rosemount.com
125
Rosemount 3051S Series
October 2014
Coplanar sensor module
3051S_C, 3051SMV, 3051SF, 3051SAM_ _G or A
Thermal Range Expander temperature operating
range
100
(1)(2)
Silicone Fill Sensor
80
(3)
with Level Flange
-40 to 3003 °F (-40 to 149 °C)(3)
with 305 Integral
Manifold
-40 to 300 °F (-40 to 149 °C)(3)(4)
Inert Fill Sensor(1)(5)
-40 to 185 °F (-40 to 85 °C)(6) (7)
In-Line sensor module
3051S_T, 3051SAM_ _T or E
Silicone Fill Sensor(1)
-40 to 250 °F (-40 to 121 °C)(3)
Inert Fill Sensor(1)
-22 to 250 °F (-30 to 121 °C)(3)
3051SAL Level Transmitter
Silicone 705
40
UltraTherm
805
20
0
410°C
-40 to 300 °F (-40 to 149 °C)(3)(4)
370°C
with Traditional Flange
Silicone 704
60
315°C
-40 to 250 °F (-40 to 121 °C)
Ambient Temperature (°C)
with Coplanar Flange
-20
-40
-60
-80
-30
10
50
90
130
170
210
250
Process Temperature (°C)
290
330
370
410
Humidity limits
0–100% relative humidity
SYLTHERM XLT
-102 to 293 °F (-75 to 145 °C)
Silicone 704(8)
32 to 401 °F (0 to 205 °C)
Turn-on time(1)
Silicone 705(8)
68 to 401 °F (20 to 205 °C)
UltraTherm(8)
-49 to 401 °F (-45 to 205 °C)
When power is applied to the transmitter during startup,
performance will be within specifications per the time period
described below:
Silicone 200
-49 to 401 °F (-45 to 205 °C)
Inert (Halocarbon)
-49 to 320 °F (-45 to 160 °C)
Glycerin and Water
5 to 203 °F (-15 to 95 °C)
Neobee M-20®(9)
5 to 401 °F (-15 to 205 °C)
Propylene Glycol and
Water
5 to 203 °F (-15 to 95 °C)
Transmitter
Turn-on time (typical)
3051S, 3051SF_D, 3051SAL_ _C
Diagnostics
3051SMV, 3051SF_1-7
3051S ERS System
2 seconds
5 seconds
5 seconds
6 seconds
(1) Does not apply to wireless option code X.
(1) Process temperatures above 185 °F (85 °C) require derating the ambient
limits by a 1.5:1 ratio. For example, for process temperature of 195 °F (91
°C), new ambient temperature limit is equal to 170 °F (77 °C). This can be
determined as follows:
(195 °F - 185 °F) x 1.5 = 15 °F,
185 °F - 15 °F = 170 °F
(2) 212 °F (100 °C) is the upper process temperature limit for DP Range 0.
(3) 220 °F (104 °C) limit in vacuum service; 130 °F (54 °C) for pressures below
0.5 psia.
(4) -20 °F (-29 °C) is the lower process temperature limit with option code P0.
(5) 32 °F (0 °C) is the lower process temperature limit for DP Range 0.
Volumetric displacement
Less than 0.005 in3 (0,08 cm3)
Damping(1)
Analog output response time to a step change is user-selectable
from 0 to 60 seconds for one time constant. For 3051SMV,
3051SF_1-7, each variable can be individually adjusted.
Software damping is in addition to sensor module response
time.
(1) Does not apply to wireless option code X.
(6) For 3051S_C, 160 ° F (71 °C) limit in vacuum service.
For 3051SMV_ _ 1, 2, 140 ° F (60 °C) limit in vacuum service.
Failure mode alarm
(7) Not available for 3051S_CA.
4-20 mA HART (output option code A)
(8) Upper temperature limit is 464 °F (240 °C) for a 2-in. direct-mount
extension, 500 °F (260 °C) for a 4-in. direct-mount extension, and 599 °F
(315 °C) for an In-Line Thermal Range Expander direct-mount
connection.
(9) Upper temperature limit is 437 °F (225 °C) for a 2-in. direct-mount
extension or greater.
126
If self-diagnostics detect a gross transmitter failure, the analog
signal will be driven offscale to alert the user. Rosemount
standard (default), NAMUR, and custom alarm levels are
available (see below).
High or low alarm signal is software-selectable or
hardware-selectable via the optional switch (option D1).
www.rosemount.com
October 2014
Rosemount 3051S Series
Process connections
Alarm configuration
Default
(1)
NAMUR compliant
(2)(3)
Custom levels
High alarm
Low alarm
≥ 21.75 mA
≤ 3.75 mA
≥ 22.5 mA
≤ 3.6 mA
20.2 - 23.0 mA
3.4 - 3.8 mA
(1) Analog output levels are compliant with NAMUR recommendation NE
43, see option codes C4 or C5.
Coplanar sensor module
(3051S_C, 3051SMV, 3051SF, 3051SAM_ _G or A)
Standard
1
/4-18 NPT on 21/8-in. centers
Flange
Adapters
1
/2-14 NPT and RC 1/2 on 2-in. (50.8 mm), 21/8-in.
(54.0 mm), or 21/4-in. (57.2 mm) centers
In-line sensor module
(3051S_T, 3051SAM_ _T or E)
Standard
1
(2) Low alarm must be 0.1 mA less than low saturation and high alarm must
be 0.1 mA greater than high saturation.
F11 Code
Non-threaded instrument flange (available in SST
for sensor ranges 1-4 only)
(3) For 3051SMV and option code DA2, low alarm custom values are 3.6 - 3.8
mA.
G11 Code
G 1/2 A DIN 16288 male (available in SST for
sensor ranges 1-4 only)
H11 Code
Autoclave type F-250C (Pressure relieved 9/16-18
gland thread; 1/4 OD high pressure tube 60° cone;
available in SST for sensor range 5 only)
Safety-certified transmitter failure values(1)
Device Safety accuracy: ± 2.0% of analog output span (2)
Level transmitter
(3051SAL)
Device Safety response time: 1.5 seconds
(1) Does not apply to wireless option code X.
FF Seal
PF Seal
(2) Trip values in the DCS or safety logic solver should be derated by this
device safety accuracy.
/2-14 NPT Female
EF Seal
2-in. (DN 50), 3-in. (DN 80), or 4-in. (DN 100);
ANSI Class 150, 300, 600, 900, 1500, and 2500
flange; JIS 10K, 20K, or 40K flange; PN 10/16 or
PN 40 flange
RF Seal
1-in. (DN 25) or 11/2-in. (DN 40); ANSI Class 150,
300, or 600 flange; JIS 10K, 20K, or 40K flange;
PN 40 flange
Physical specifications
RT Seal
1/4-18, 1/2-14, 3/4-14, or 1-11.5 NPT Female
Material selection
FC Seal
2-in. or 3-in.; ANSI Class 150, 300, 600, 900,
1500, 2500 flange; PN 63 or PN 100 flange
RC Seal
1
/2-in., 3/4-in., 1-in., or 11/2-in.; ANSI Class 150,
300, 600, 900, 1500, 2500 flange; PN 63 or PN
100 flange
SC Seal
11/2-in, 2-in, or 3-in. Hygienic Tri-Clover Style
Tri-Clamp
SS Seal
4-in. Hygienic Tank Spud
Emerson provides a variety of Rosemount products with various
product options and configurations including materials of
construction that can be expected to perform well in a wide
range of applications. The Rosemount product information
presented is intended as a guide for the purchaser to make an
appropriate selection for the application. It is the purchaser’s
sole responsibility to make a careful analysis of all process
parameters (such as all chemical components, temperature,
pressure, flow rate, abrasives, contaminants, etc.), when
specifying product materials, options, and components for the
particular application. Emerson Process Management is not in a
position to evaluate or guarantee the compatibility of the
process fluid or other process parameters with the product
options, configuration, or materials of construction selected.
Electrical connections
1
/2–14 NPT, G1/2, and M20 × 11/2 conduit. HART interface
connections fixed to terminal block for Output code A and X.
www.rosemount.com
127
Rosemount 3051S Series
Process-wetted parts
Process isolating diaphragms
Coplanar sensor module
(3051S_C, 3051SMV)
316L SST (UNS S31603), Alloy C-276 (UNS N10276), Alloy 400
(UNS N04400), Tantalum (UNS R05440), Gold-Plated Alloy
400, Gold-plated 316L SST
B11 Code Low side process connection is SST
In-line sensor module
(3051S_T)
316L SST (UNS S31603), Alloy C-276 (UNS N10276)
Level transmitter
(3051SAL)
FF Seal
EF Seal
RF Seal
RT Seal
PF Seal
FC Seal
RC Seal
SC Seal
SS Seal
316L SST, Alloy C-276, Tantalum
Bolts
Plated carbon steel per ASTM A449, Type 1
Austenitic 316 SST per ASTM F593
ASTM A453, Class D, Grade 660 SST
ASTM A193, Grade B7M alloy steel
ASTM A193, Class 2, Grade B8M SST
Alloy K-500
Sensor module fill fluid
Silicone is standard.
Inert is available as option code (L1).(1)
Inert for In-Line series uses Fluorinert® FC-43.
Inert for Coplanar series uses Halocarbon.
Seal fill fluid (liquid level only)
3051SAL: Silicone 200, Silicone 704, Silicone 705, UltraTherm
805, inert, SYLTHERM XLT, Neobee M-20, glycerin and water,
propylene glycol and water.
Paint for aluminum housing
Polyurethane
Cover O-rings
Buna-N
316L SST, Alloy C-276
Drain/vent valves
316 SST, Alloy C-276, or Alloy 400/K-500(1) material
(Drain vent seat: Alloy 400, Drain vent stem: Alloy K-500)
(1)
October 2014
Wireless antenna
External Antenna (WK / WM): PBT/PC integrated
omni-directional antenna
Remote Antenna (WN): Fiberglass omni-directional antenna
Alloy 400/K-500 is not available with 3051SAL.
Process flanges and flange adapters
Plated carbon steel
SST: CF-8M (Cast 316 SST) per ASTM A743
Cast C-276: CW-12MW per ASTM A494
Cast Alloy 400: M-30C per ASTM A494
Wetted O-rings
Glass-filled PTFE
(Graphite-filled PTFE with Isolating Diaphragm code 6)
3051SAL mounting flange
Zinc-cobalt plated CS or 316 SST
3051SAL seal extension
CF-3M (Cast 316L SST, material per ASTM A743) or
CW-12MW (Cast C-276, material per ASTM A494)
Non-wetted parts
Electronics housing
Low-copper aluminum alloy or CF-8M (Cast 316 SST)
NEMA® 4X, IP 66, IP 68 (66 ft (20 m) for 168 hours)
Note: IP 68 not available with Wireless Output.
Coplanar sensor module housing
SST: CF-3M (Cast 316L SST)
(1)
128
Inert is not available with 3051S_CA.
www.rosemount.com
October 2014
Rosemount 3051S Series
Power module
Field replaceable, keyed connection eliminates the risk of
incorrect installation, Intrinsically Safe Lithium-thionyl chloride
Power Module with PBT enclosure Shipping weights
Sensor module weights
Coplanar sensor module(1)
3.1 lb (1,4 kg)
In-line sensor module
1.4 lb (0,6 kg)
(1) Flange and bolts not included.
Transmitter weights(1)
Transmitter with coplanar sensor module
(3051S_C, 3051SMV, 3051SAM_ _G or A)
Junction Box housing, SST
Flange
6.3 lb (2,8 kg)
PlantWeb housing, SST Flange
6.7 lb (3,1 kg)
Wireless PlantWeb housing,
SST Flange
7.3 lb (3,3 kg)
Transmitter with in-line sensor module (3051S_T,
3051SAM_ _T or E)
Junction Box housing
3.2 lb (1,4 kg)
PlantWeb housing
3.7 lb (1,7 kg)
Wireless PlantWeb housing
4.2 lb (1,9 kg)
(1) Fully functional transmitter with sensor module, housing, terminal
block, and covers. Does not include LCD display.
www.rosemount.com
129
Rosemount 3051S Series
October 2014
Transmitter option weights
Option code
Option
Add lb (kg)
1J, 1K, 1L
SST PlantWeb housing
3.5 (1,6)
2J
SST Junction Box housing
3.4 (1,5)
7J
SST Quick Connect
0.4 (0,2)
2A, 2B, 2C
Aluminum Junction Box housing
1.1 (0,5)
1A, 1B, 1C
Aluminum PlantWeb housing
1.1 (0,5)
(1)
M5
LCD display for Aluminum PlantWeb housing ,
LCD display for SST PlantWeb housing(1)
0.8 (0,4)
1.6 (0,7)
B4
SST Mounting Bracket for Coplanar Flange
1.2 (0,5)
B1, B2, B3
Mounting Bracket for Traditional Flange
1.7 (0,8)
B7, B8, B9
Mounting Bracket for Traditional Flange with SST Bolts
1.7 (0,8)
BA, BC
SST Bracket for Traditional Flange
1.6 (0,7)
B4
SST Mounting Bracket for In-Line
1.3 (0,6)
F12, F22
SST Traditional Flange with SST Drain Vents(2)
3.2 (1,5)
F13, F23
Cast C-276 Traditional Flange with Alloy C-276 Drain Vents(2)
3.6 (1,6)
E12, E22
SST Coplanar Flange with SST Drain Vents(2)
1.9 (0,9)
F14, F24
Cast Alloy 400 Traditional Flange with Alloy 400/K-500 Drain Vents(2)
3.6 (1,6)
F15, F25
SST Traditional Flange with Alloy C-276 Drain Vents(2)
3.2 (1,5)
G21
Level Flange—3 in., 150
12.6 (5,7)
G22
Level Flange—3 in., 300
15.9 (7,2)
G11
Level Flange—2 in., 150
6.8 (3,1)
G12
Level Flange—2 in., 300
8.2 (3,7)
G31
DIN Level Flange, SST, DN 50, PN 40
7.8 (3,5)
G41
DIN Level Flange, SST, DN 80, PN 40
13.0 (5,9)
(1) Includes LCD display and display cover.
(2) Includes mounting bolts.
Transmitter component weights
Item
Weight in lb. (kg)
Aluminum Standard Cover
0.4 (0,2)
SST Standard Cover
1.3 (0,6)
Aluminum Display Cover
0.7 (0,3)
SST Display Cover
1.5 (0,7)
Wireless Extended Cover
0.7 (0,3)
LCD Display(1)
0.1 (0,04)
Junction Box Terminal Block
0.2 (0,1)
PlantWeb Terminal Block
0.2 (0,1)
Power Module
0.5 (0,2)
(1) Display only
130
www.rosemount.com
October 2014
Rosemount 3051S Series
3051SAL weights without supermodule platform, housing, or transmitter options
Flange
Flush
lb. (kg)
2-in. Ext.
lb (kg)
4-in. Ext.
lb (kg)
6-in. Ext.
lb (kg)
2-in., 150
9.5 (4,3)
N/A
N/A
N/A
3-in., 150
15.7 (7,1)
16.4 (7,4)
17.6 (8,0)
18.9 (8,6)
4-in., 150
21.2 (9,6)
20.9 (9,5)
22.1 (10,0)
23.4 (10,6)
2-in., 300
11.3 (5,1)
N/A
N/A
N/A
3-in., 300
19.6 (8,9)
20.3 (9,2)
21.5 (9,8)
22.8 (10,3)
4-in., 300
30.4 (13.8)
30.3 (13,7)
31.5 (14,3)
32.8 (14,9)
2-in., 600
12.8 (5,8)
N/A
N/A
N/A
3-in., 600
22.1 (10,0)
22.8 (10,3)
24.0 (10,9)
25.3 (11,5)
DN 50 / PN 40
11.3 (5,1)
N/A
N/A
N/A
DN 80 / PN 40
16.0 (7,3)
16.7 (7,6)
17.9 (8,1)
19.2 (8,7)
DN 100 / PN 10/16
11.2 (5,1)
11.9 (5,4)
13.1 (5,9)
14.4 (6,5)
DN 100 / PN 40
12.6 (5,7)
13.3 (6,0)
14.5 (6,6)
15.8 (7,1)
www.rosemount.com
131
Rosemount 3051S Series
October 2014
Rosemount 3051S/3051SFx (Measurement Type D)/
3051S ERS Certifications
European Directive Information
A copy of the EC Declaration of Conformity can be found at the
end of the Quick Start Guide. The most recent revision of the EC
Declaration of Conformity can be found at
www.rosemount.com.
Ordinary Location Certification from FM
Approvals
Note
Transmitters marked with NI CL 1, DIV 2 can be installed in
Division 2 locations using general Division 2 wiring methods or
Nonincendive Field Wiring (NIFW). See Drawing 03151-1006.
IE
FM FISCO Field Device
Certificate:3012350
Standards: FM Class 3600 – 2011, FM Class 3610 – 2010,
FM Class 3611 – 2004, FM Class 3810 – 2005,
NEMA 250 –2003
Markings: IS CL I, DIV 1, GP A, B, C, D; (-50 °C ≤ Ta ≤
+60 °C); when connected per Rosemount
drawing 03151-1006; Type 4x
As standard, the transmitter has been examined and tested to
determine that the design meets the basic electrical,
mechanical, and fire protection requirements by FM Approvals,
a nationally recognized test laboratory (NRTL) as accredited by
the Federal Occupational Safety and Health Administration
(OSHA).
North America
Special Condition for Safe Use (X):
1. The Model 3051S/3051S ERS Pressure Transmitter
contains aluminum and is considered to constitute a
potential risk of ignition by impact or friction. Care must
be taken into account during installation and use to
prevent impact and friction.
The US National Electrical Code (NEC) and the Canadian
Electrical Code (CEC) permit the use of Division marked
equipment in Zones and Zone marked equipment in Divisions.
The markings must be suitable for the area classification, gas,
and temperature class. This information is clearly defined in the
respective codes.
Canada
United States of America
E6
CSA Explosionproof, Dust-Ignitionproof, and Division 2
Certificate: 143113
Standards: CAN/CSA C22.2 No. 0-10, CSA Std C22.2 No.
25-1966, CSA Std C22.2 No. 30-M1986,
CAN/CSA C22.2 No. 94-M91, CSA Std C22.2
No. 142-M1987, CSA Std C22.2 No.
213-M1987, ANSI/ISA 12.27.01-2003, CSA
Std C22.2 No. 60529:05
Markings: Explosionproof Class I, Division 1, Groups B, C,
D; Dust-Ignitionproof Class II, Division 1,
Groups E, F, G; Class III; suitable for Class I, Zone
1, Group IIB+H2, T5; suitable for Class I,
Division 2, Groups A, B, C, D; suitable for Class I,
Zone 2, Group IIC, T5; when connected per
Rosemount drawing 03151-1013; Type 4x
I6
CSA Intrinsically Safe
Certificate: 1143113
Standards: CAN/CSA C22.2 No. 0-10, CSA Std C22.2 No.
30-M1986, CAN/CSA C22.2 No. 94-M91, CSA}
Std C22.2 No. 142-M1987, CSA Std C22.2 No.
157-92, ANSI/ISA 12.27.01-2003, CSA Std
C22.2 No. 60529:05
Markings: Intrinsically Safe Class I, Division 1; suitable for
Class 1, Zone 0, IIC, T3C; when connected per
Rosemount drawing 03151-1016; Type 4x
E5
FM Explosionproof (XP) and Dust-Ignitionproof (DIP)
Certificate: 3008216
Standards: FM Class 3600 – 2011, FM Class 3615 – 2006,
FM Class 3616-2011, 3810 – 2005, ANSI/NEMA
250 – 2003
Markings: XP CL I, DIV 1, GP B, C, D; DIP CL II, DIV 1, GP E, F,
G; CL III;T5(-50 °C ≤ Ta ≤ +85 °C); Factory
Sealed; Type 4X
I5
FM Intrinsic Safety (IS) and Nonincendive (NI)
Certificate: 3012350
Standards: FM Class 3600 – 2011, FM Class 3610 – 2010,
FM Class 3611 – 2004, FM Class 3810 – 2005,
NEMA 250 –2003
Markings: IS CL I, DIV 1, GP A, B, C, D; CL II, DIV 1, GP E, F,
G; Class III; Class 1, Zone 0 AEx ia IIC T4; NI CL 1,
DIV 2, GP A, B, C, D; T4(-50°C ≤ Ta ≤ +70°C)
[HART]; T4(-50 °C ≤ Ta ≤ +60 °C) [fieldbus];
when connected per Rosemount drawing
03151-1006; Type 4x
Special Condition for Safe Use (X):
1. The Model 3051S/3051S ERS Pressure Transmitter
contains aluminum and is considered to constitute a
potential risk of ignition by impact or friction. Care must
be taken into account during installation and use to
prevent impact and friction.
132
www.rosemount.com
October 2014
IF
Rosemount 3051S Series
CSA FISCO Field Device
Certificate: 1143113
Standards: CAN/CSA C22.2 No. 0-10, CSA Std C22.2 No.
30-M1986, CAN/CSA C22.2 No. 94-M91, CSA
Std C22.2 No. 142-M1987, CSA Std C22.2 No.
157-92, ANSI/ISA 12.27.01-2003, CSA Std
C22.2 No. 60529:05
Markings: FISCO Intrinsically Safe Class I, Division 1;
suitable for Class I, Zone 0; T3C; when installed
per Rosemount drawing 03151-1016; Type 4X
Europe
E1
ATEX Flameproof
Certificate: KEMA 00ATEX2143X
Standards: EN 60079-0:2012, EN 60079-1: 2007, EN
60079-26:2007 (3051SFx models with RTD are
certified to EN60079-0:2006)
Markings:
II 1/2 G Ex d IIC T6…T4 Ga/Gb,
T6(-60 °C ≤ Ta ≤ +70 °C), T5/
T4(-60 °C ≤ Ta ≤ +80 °C)
Model
Ui
Ii
Pi
Ci
Li
3051S
…A…M7, M8,
or M9; 3051SF
…A…M7, M8,
or M9;
3051SAL…C…
M7, M8, or M9
30 V
300 mA
1.0 W
11.4 nF
60 μH
3051SAL or
3051SAM
30 V
300 mA
1.0 W
11.4 nF
33 μH
3051SAL…M7,
M8, or M9
3051SAM…M7
, M8, or M9
30 V
300 mA
1.0 W
11.4 nF 93 μ H
RTD Option for
3051SF
5V
500 mA
0.63 W
-60 °C to +70 °C
T5
-60 °C to +80 °C
T4
-60 °C to +120 °C
1. The Model 3051S Transmitters fitted with transient
protection are not capable of withstanding the 500V test
as defined in Clause 6.3.13 of EN 60079-11:2012. This
must be taken into account during installation.
2. The terminal pins of the Model 3051S SuperModule must
be provided with a degree of protection of at least IP20 in
accordance with IEC/EN 60529.
IA
Special Conditions for Safe Use (X):
1. The device contains a thin wall diaphragm. Installation,
maintenance and use shall take into account the
environmental conditions to which the diaphragm will be
subjected. The manufacturer’s instructions for installation
and maintenance shall be followed in detail to assure
safety during its expected lifetime.
2. For information on the dimensions of the flameproof
joints, the manufacturer shall be contacted.
I1
ATEX Intrinsic Safety
Certificate: BAS01ATEX1303X
Standards: EN 60079-0: 2012, EN 60079-11: 2012
Markings:
II 1 G Ex ia IIC T4 Ga, T4(-60 °C ≤ Ta ≤ +70 °C)
Input Parameters
Model
Ui
Ii
Pi
Ci
Li
SuperModule
30 V
300 mA
1.0 W
30 nF
0
3051S...A;
3051SF…A;
3051SAL…C
30 V
300 mA
1.0 W
12 nF
0
3051S…F;
3051SF…F
30 V
300 mA
1.3 W
0
0
3051S …F…IA;
3051SF …F…IA
17.5
V
380 mA
5.32 W
0
0
www.rosemount.com
N/A
Special Conditions for Safe Use (X):
Temperature class Process temperature
T6
N/A
ATEX FISCO Field Device
Certificate: BAS01ATEX1303X
Standards: EN 60079-0: 2012, EN 60079-11: 2012
Markings:
II 1 G Ex ia IIC T4 Ga, T4(-60 °C ≤ Ta ≤ +70 °C)
FISCO
Voltage Ui
17.5 V
Current Ii
380 mA
Power Pi
5.32 W
Capacitance Ci
0
Inductance Li
0
Special Conditions for Safe Use (X):
1. The Model 3051S Transmitters fitted with transient
protection are not capable of withstanding the 500V test
as defined in Clause 6.3.13 of EN 60079-11:2012. This
must be taken into account during installation.
2. The terminal pins of the Model 3051S SuperModule must
be provided with a degree of protection of at least IP20 in
accordance with IEC/EN 60529.
133
Rosemount 3051S Series
ND ATEX Dust
Certificate: BAS01ATEX1374X
Standards: EN 60079-0: 2012, EN 60079-31: 2009
Markings:
II 1 D Ex ta IIIC T105 °C T50095 °C Da,
(-20 °C ≤ Ta ≤ +85 °C), Vmax = 42.4V
October 2014
Special Conditions for Safe Use (X):
1. The device contains a thin wall diaphragm. Installation,
maintenance and use shall take into account the
environmental conditions to which the diaphragm will be
subjected. The manufacturer’s instructions for installation
and maintenance shall be followed in detail to assure
safety during its expected lifetime.
Special Conditions for Safe Use (X):
1. Cable entries must be used which maintain the ingress
protection of the enclosure to at least IP66.
2. For information on the dimensions of the flameproof joints
the manufacturer shall be contacted.
2. Unused cable entries must be filled with suitable blanking
plugs which maintain the ingress protection of the
enclosure to at least IP66.
3. Cable entries and blanking plugs must be suitable for the
ambient temperature range of the apparatus and capable
of withstanding a 7J impact test.
Certificate: IECEx BAS 09.0014X (Dust)
Standards: IEC 60079-0:2011, IEC 60079-31:2008
Markings: Ex ta IIIC T105°C T50095°C Da,
(-20 °C ≤ Ta ≤ +85 °C), Vmax = 42.4V
Special Conditions for Safe Use (X):
4. The SuperModule(s) must be securely screwed in place to
maintain the ingress protection of the enclosure(s).
N1
1. Cable entries must be used which maintain the ingress
protection of the enclosure to at least IP66.
ATEX Type n
Certificate: BAS01ATEX3304X
Standards: EN 60079-0: 2012, EN 60079-15: 2010
Markings:
II 3 G Ex nA IIC T5 Gc, (-40 °C ≤ Ta ≤ +85 °C),
Vmax = 45V
2. Unused cable entries must be filled with suitable blanking
plugs which maintain the ingress protection of the
enclosure to at least IP66.
3. Cable entries and blanking plugs must be suitable for the
ambient temperature range of the apparatus and capable
of withstanding a 7J impact test.
Special Condition for Safe Use (X):
1. The equipment is not capable of withstanding the 500V
insulation test required by clause 6.5 of EN
60079-15:2010. This must be taken into account when
installing the equipment.
Note
RTD Assembly is not included with the 3051SFx Type n Approval.
134
I7
IECEx Intrinsic Safety
Certificate: IECEx BAS 04.0017X
Standards: IEC 60079-0: 2011, IEC 60079-11: 2011
Markings: Ex ia IIC T4 Ga, T4(-60°C ≤ Ta ≤ +70°C)
Input parameters
Model
International
E7
4. The 3051S- SuperModule must be securely screwed in
place to maintain the ingress protection of the enclosure.
Ui
Ii
Pi
Ci
Li
SuperModule
30 V
300 mA
1.0 W
30 nF
0
IECEx Flameproof and Dust
Certificate: IECEx KEM 08.0010X (Flameproof)
Standards: IEC 60079-0:2011, IEC 60079-1: 2007, IEC
60079-26:2006, (3051SFx models with RTD are
certified to IEC 60079-0:2004)
Markings: Ex d IIC T6…T4 Ga/Gb, T6(-60 °C ≤ Ta ≤ +70 °C),
T5/T4(-60 °C ≤ Ta ≤ +80 °C)
3051S...A;
3051SF…A;
3051SAL…C
30 V
300 mA
1.0 W
12 nF
0
3051S…F;
3051SF…F
30 V
300 mA
1.3 W
0
0
3051S …F…IA;
3051SF …F…IA
17.5
V
380 mA
5.32 W
0
0
Temperature class Process temperature
3051S
…A…M7, M8,
or M9; 3051SF
…A…M7, M8,
or M9;
3051SAL…C…
M7, M8, or M9
30 V
300 mA
1.0 W
11.4 nF
60 μH
3051SAL or
3051SAM
30 V
300 mA
1.0 W
11.4 nF
33 μH
3051SAL…M7,
M8, or M9
3051SAM…M7
, M8, or M9
30 V
300 mA
1.0 W
11.4 nF
93 μ H
RTD Option for
3051SF
5V
500 mA
0.63 W
N/A
N/A
T6
-60 °C to +70 °C
T5
-60 °C to +80 °C
T4
-60 °C to +120 °C
www.rosemount.com
October 2014
Rosemount 3051S Series
Special Conditions for Safe Use (X):
IG
IECEx FISCO
Certificate: IECEx BAS 04.0017X
Standards: IEC 60079-0: 2011, IEC 60079-11: 2011
Markings: Ex ia IIC T4 Ga, T4(-60 °C ≤ Ta ≤ +70 °C)
1. The Model 3051S Transmitters fitted with transient
protection are not capable of withstanding the 500V test
as defined in Clause 6.3.13 of IEC 60079-11:2011. This
must be taken into account during installation.
FISCO
2. The terminal pins of the Model 3051S SuperModule must
be provided with a degree of protection of at least IP20 in
accordance with IEC/EN 60529.
3. The Model 3051S enclosure may be made of aluminum
alloy and given a protective polyurethane paint finish;
however, care should be taken to protect it from impact or
abrasion if located in a zone 0 area.
I7
IECEx Intrinsic Safety – Group I - Mining (I7 with Special
A0259)
Certificate: IECEx TSA 14.0019X
Standards: IEC 60079-0: 2011, IEC 60079-11: 2011
Markings: Ex ia I Ma (-60 °C ≤ Ta ≤ +70 °C)
Special Conditions for Safe Use (X):
1. If the apparatus is fitted with an optional 90V transient
suppressor, it is not capable of withstanding the 500V
insulation test required by clause 6.6.13 of IEC60079-11.
This must be taken into account when installing the
apparatus.
2. It is a condition of safe use that the following parameters
shall be taken into account during installation.
Ii
Pi
Ci
Li
SuperModule
30 V
300 mA
1.0 W
30 nF
0
3051S...A;
3051SF…A;
3051SAL…C
30 V
300 mA
1.0 W
12 nF
0
3051S…F;
3051SF…F
30 V
300 mA
1.3 W
0
0
3051S …F…IA;
3051SF …F…IA
17.5
V
380 mA
5.32 W
0
0
3051S …A…M7,
M8, or M9;
3051SF …A…M7,
M8, or M9;
3051SAL…C…
M7, M8, or M9
30 V
300 mA
1.0 W
11.4 nF
60 μH
3051SAL or
3051SAM
30 V
300 mA
1.0 W
11.4 nF
33 μH
3051SAL…M7,
M8, or M9
3051SAM…M7,
M8, or M9
30 V
300 mA
1.0 W
11.4 nF
93 μ H
RTD Option for
3051SF
5V
500 mA
0.63 W
N/A
N/A
Current Ii
380 mA
Power Pi
5.32 W
Capacitance Ci
0
Inductance Li
0
1. The Model 3051S Transmitters fitted with transient
protection are not capable of withstanding the 500V test
as defined in Clause 6.3.13 of IEC 60079-11:2011. This
must be taken into account during installation.
2. The terminal pins of the Model 3051S SuperModule must
be provided with a degree of protection of at least IP20 in
accordance with IEC/EN 60529.
3. The Model 3051S enclosure may be made of aluminum
alloy and given a protective polyurethane paint finish;
however, care should be taken to protect it from impact or
abrasion if located in a zone 0 area.
N7
Ui
17.5 V
Special Conditions for Safe Use (X):
Input parameters
Model
Voltage Ui
IECEx Type n
Certificate: IECEx BAS 04.0018X
Standards: IEC 60079-0: 2011, IEC 60079-15: 2010
Markings: Ex nA IIC T5 Gc, (-40 °C ≤ Ta ≤ +85 °C)
Special Conditions for Safe Use (X):
1. The equipment is not capable of withstanding the 500V
insulation test required by clause 6.5 of IEC
60079-15:2010. This must be taken into account when
installing the equipment.
Brazil
E2
INMETRO Flameproof
Certificate: CEPEL 03.0140X [Mfg USA, Singapore,
Germany], CEPEL 07.1413X [Mfg Brazil]
Standards: ABNT NBR IEC 60079-0:2008, ABNT NBR IEC
60079-1:2009, ABNT NBR IEC 60529:2009
Markings: Ex d IIC T* Ga/Gb, T6(-40 °C ≤ Ta ≤ +65 °C),
T5(-40 °C ≤ Ta ≤ +80 °C), IP66(Al)/IP66W(SST)
Special Conditions for Safe Use (X):
3. It is a condition of manufacture that only the apparatus
fitted with housings, junction boxes, covers and sensor
module housings made out of stainless steel are used in
Group I applications.
www.rosemount.com
1. For ambient temperature above 60 °C, cable wiring must
have minimum isolation temperature of 90 °C, to be in
accordance to equipment operation temperature.
2. The device contains a thin wall diaphragm. Installation,
maintenance and use shall take into account the
environmental conditions to which the diaphragm will be
subjected. The manufacturer’s instructions for installation
and maintenance shall be followed in detail to assure
safety during its expected lifetime.
135
Rosemount 3051S Series
I2
October 2014
INMETRO Intrinsic Safety
Certificate: CEPEL 05.0722X [Mfg USA, Singapore,
Germany], CEPEL 07.1414X [Mfg Brazil]
Standards: ABNT NBR IEC 60079-0:2008, ABNT NBR IEC
60079-11:2009, ABNT NBR IEC
60079-26:2008, ABNT
NBR IEC 60529:2009
Markings: Ex ia IIC T4 Ga, T4(-20 °C ≤ Ta ≤ +70 °C),
IP66(Al)/IP66W(SST)
Special Conditions for Safe Use (X):
1. The Model 3051S Transmitters fitted with transient
protection are not capable of withstanding the 500V test
as defined in Clause 6.4.12 of IEC 60079-11. This must be
taken into account during installation.
HART
Fieldbus
RTD (for
3051SFx)
Voltage Ui
30 V
30 V
5V
Current Ii
300 mA
300 mA
500 mA
Power Pi
1W
1.3 W
0.63 W
Capacitance Ci
12 nF
0
0
Inductance Li
0
0
0
IB
INMETRO FISCO
Certificate: CEPEL 05.0722X [Mfg USA, Singapore,
Germany], CEPEL 07.1414X [Mfg Brazil]
Standards: ABNT NBR IEC 60079-0:2008, ABNT NBR IEC
60079-11:2009, ABNT NBR IEC
60079-26:2008, ABNT
NBR IEC 60529:2009
Markings: Ex ia IIC T4 Ga, T4(-20 °C ≤ Ta ≤ +40 °C),
IP66(Al)/IP66W(SST)
FISCO
Voltage Ui
17.5 V
Current Ii
380 mA
Power Pi
5.32 W
Capacitance Ci
0
Inductance Li
0
Special Condition for Safe Use (X):
1. The Model 3051S Transmitters fitted with transient
protection are not capable of withstanding the 500V test
as defined in Clause 6.4.12 of IEC 60079-11. This must be
taken into account during installation.
China
E3
China Flameproof and Dust Ignition-proof
Certificate: 3051S: GYJ091035 [Mfg USA], GYJ111400X
[Mfg China, Singapore]
3051SFx: GYJ071086 [Mfg USA, China,
Singapore]
Standards: 3051S: GB3836.1-2000, GB3836.2-2000,
GB12476.1-20003051SFx: GB3836.1-2000,
GB3836.2-2000, GB12476.1-2000
Markings: 3051S: Ex d IIC T5/T6; DIP A20TA105°C; IP66
3051SFx: Ex d IIC T5/T6; Ex d IIB+H2T3~T5; DIP
A21 TA T3~T5
Special Conditions for Safe Use (X):
1. Only the pressure transmitters, consisting of 3051SC
Series, 3051ST Series, 3051SL Series and 300S Series, are
certified.
2. The ambient temperature range is (-20 ~+60) °C.
3. The relation between temperature class and maximum
temperature of process medium is as follows:
Temperature
class
Temperature of process
medium (°C)
T5
≤ 95 °C
T4
≤ 130 °C
T3
≤ 190 °C
4. The earth connection facility in the enclosure should be
connected reliably.
5. During installation, use and maintenance of transmitter,
observe the warning “Don’t open the cover when the
circuit is alive.”
6. During installation, there should be no mixture harm to
flameproof housing.
7. Cable entry, certified by NEPSI with type of protection Ex d
IIC in accordance with GB3836.1-2000 and
GB3836.2-2000, should be applied when installation in
hazardous location. 5 full threads should be in
engagement when the cable entry is assembled onto the
transmitter. When pressure transmitter is used in the
presence of combustible dust, the ingress of protection of
the cable entry should be IP66.
8. The diameter of cable should observe the instruction
manual of cable entry. The compressing nut should be
fastened. The aging of seal ring should be changed in time.
9. Maintenance should be done in non-hazardous location.
10. End users are not permitted to change any components
inside.
11. When installation, use and maintenance of transmitter,
136
www.rosemount.com
October 2014
Rosemount 3051S Series
observe following standards:
•GB3836.13-1997 “Electrical apparatus for explosive gas
atmospheres Part 13: Repair and overhaul for apparatus
used in explosive gas atmospheres”
•GB3836.15-2000 “Electrical apparatus for explosive gas
atmospheres Part 15: Electrical installations in hazardous
area (other than mines)”
•GB50257-1996 “Code for construction and acceptance of
electric device for explosion atmospheres and fire hazard
electrical equipment installation engineering”
•GB15577-1995 “Safe regulation for explosive dust
atmospheres”
•GB12476.2-2006 “Electrical apparatus for use in the
presence of combustible dust – Part 1-2: Electrical apparatus
protected by enclosures and surface temperature limitation
– Selection, installation and maintenance”
I3
China Intrinsic Safety
Certificate: 3051S: GYJ111401X [Mfg USA, China,
Singapore]
3051SF: GYJ11.1707X [Mfg USA, China,
Singapore]
Standards: 3051S: GB3836.1-2000, GB3836.4-2000
3051SF: GB3836.1/4-2010, GB3836.20-2010
GB12476.1-2000
Markings: 3051S: Ex ia IIC T4
3051SF: Ex ia IIC T4 Ga, DIP A20 TA105 °C IP66
Special Conditions for Safe Use (X):
6. The product complies to the requirements for FISCO field
devices specified in IEC60079-27:2008. For the connection
of an intrinsically safe circuit in accordance FISCO model,
FISCO parameters of this product are as above.
7. End users are not permitted to change any components
inside, but to settle the problem in conjunction with
manufacturer to avoid damage to the product.
8. When installation, use and maintenance of this product,
observe the following standards:
•GB3836.13-1997 “Electrical apparatus for explosive gas
atmospheres Part 13: Repair and overhaul for apparatus
used in explosive gas atmospheres”
•GB3836.15-2000 “Electrical apparatus for explosive gas
atmospheres Part 15: Electrical installations in hazardous
area (other than mines)”
•GB3836.16-2006 “Electrical apparatus for explosive gas
atmospheres Part 16: Inspection and maintenance of
electrical installation (other than mines)”
•GB50257-1996 “Code for construction and acceptance of
electric device for explosion atmospheres and fire hazard
electrical equipment installation engineering”
N3
China Type n
Certificate: 3051S: GYJ101112X [Mfg China]
3051SF: GYJ101125X [Mfg China]
Standards: GB3836.1-2000, GB3836.8-2003
Markings: Ex nL IIC T5
Special Conditions for Safe Use (X):
1. Symbol “X” is used to denote specific conditions of use:
For output code A and F: This apparatus is not capable of
withstanding the 500V r.m.s. insulation test required by
Clause 6.4.12 of GB3836.4-2000.
1. Symbol “X” is used to denote specific conditions of use:
The apparatus is not capable of withstanding the 500V test
to earth for one minute. This must be taken into
consideration during installation.
2. The ambient temperature range is:
2. The ambient temperature range is: -40 °C ≤ Ta ≤ 70 °C.
Output code
3. Cable glands, conduit or blanking plugs, certified by NEPSI
with Ex e or Ex n protection type and IP66 degree of
protection provided by enclosure, should be used on
external connections and redundant cable entries.
Ambient temperature
A
-50 °C ≤ Ta ≤+70 °C
F
-50 °C ≤ Ta ≤+60 °C
4. Energy limiting parameters:
3. Intrinsically safe parameters:
Output Housing
code
code
Maximum Maximum Maximum Maximum Maximum
input
input
input
internal
internal
Display voltage: current:
power: parameters: parameters:
code
Ui (V)
Ii (mA)
Pi (W)
Ci (nF)
Li (uH)
A
=00
/
30
300
1
38
0
A
00
/
30
300
1
11.4
2.4
00
M7/M8
/M9
30
300
1
0
58.2
A
F
00
/
30
300
1.3
0
0
F
FISCO
00
/
17.5
500
5.5
0
0
4. The product should be used with Ex-certified associated
apparatus to establish explosion protection system that
can be used in explosive gas atmospheres. Wiring and
terminals should comply with the instruction manual of
the product and associated apparatus.
5. The cable between this product and associated apparatus
should be shielded cables (the cables must have insulated
shield). The shield has to be grounded reliably in
non-hazardous area.
www.rosemount.com
Model
Maximum Maximum Maximum Maximum Maximum
input
input
input
internal
internal
voltage: current:
power: parameters: parameters:
Ui (V)
Ii (mA)
Pi (W)
Ci (nF)
Li (uH)
Terminal
3051S-C/T
1 to 5
30
300
1
30
0
3051S HART,
4-20mA/SIS
+,- and
CAN
30
300
1
11.4
0
3051S
fieldbus/Profibus
+ and -
30
300
1.3
0
0
3051S FISCO
+ and -
17.5
380
5.32
0
0
Remote Mount
Housing
+ and -
30
300
1
24
60
Note
Remote Mount Housing is for direct connection to the Model
3051S HART Terminals +,- and CAN by a cable whose maximum
capacitance and inductance do not exceed 24nF and 60uH
respectively.
137
Rosemount 3051S Series
5. 3051S Type Pressure Transmitter comply to the
requirements for FISCO field devices specified in
IEC60079-27:2008. For the connection of an intrinsically
safe circuit in accordance FISCO model, FISCO parameters
of 3051S type Pressure Transmitter are listed in the table
above.
October 2014
Combinations
K1
Combination of E1, I1, N1, and ND
K2
Combination of E2 and I2
K5
Combination of E5 and I5
K6
Combination of E6 and I6
K7
Combination of E7, I7, and N7
KA
Combination of E1, I1, E6, and I6
KB
Combination of E5, I5, E6, and I6
KC
Combination of E1, I1, E5, and I5
8. Maintenance should be done in non-hazardous location.
KD
Combination of E1, I1, E5, I5, E6, and I6
9. End users are not permitted to change any components
inside, but to settle the problem in conjunction with
manufacturer to avoid damage to the product.
KG
Combination of IA, IE, IF, and IG
10. When installation, use and maintenance of this product,
observe following standards:
•GB3836.13-1997 “Electrical apparatus for explosive gas
atmospheres Part 13: Repair and overhaul for apparatus
used in explosive gas atmospheres”
•GB3836.15-2000 “Electrical apparatus for explosive gas
atmospheres Part 15: Electrical installations in hazardous
area (other than mines)”
•GB3836.16-2006 “Electrical apparatus for explosive gas
atmospheres Part 16: Inspection and maintenance of
electrical installation (other than mines)”
•GB50257-1996 “Code for construction and acceptance of
electric device for explosion atmospheres and fire hazard
electrical equipment installation engineering”.
KP
6. The product should be used with associated
energy-limited apparatus certified by NEPSI in accordance
with GB 3836.1-2000 and GB 3836.8-2003 to establish
explosion protection system that can be used in explosive
gas atmospheres.
7. The cables between this product and associated
energy-limited apparatus should be shielded cables (the
cables must have insulated shield). The shielded has to be
grounded reliably in non-hazardous area.
Japan
E4
Japan Flameproof
Certificate: TC15682, TC15683, TC15684, TC15685,
TC15686, TC15687, TC15688, TC15689,
TC15690, TC17099, TC17100, TC17101,
TC17102, TC18876
Markings: Ex d IIC T6
Republic of Korea
EP
IP
Republic of Korea Intrinsic Safety
Certificate: 12-KB4BO-0202X [HART – Mfg USA],
12-KB4BO-0204X [Fieldbus – Mfg USA],
12-KB4BO-0203X [HART – Mfg Singapore],
13-KB4BO-0296X [Fieldbus – Mfg Singapore]
Markings: Ex d IIC T4
EM, IM, KM Contact an Emerson Process Management
representative for additional information.
Combination of EP and IP
Additional Certifications
SBS American Bureau of Shipping (ABS) Type Approval
Certificate: 00-HS145383-6-PDA
Intended Use: Measure gauge or absolute pressure of
liquid, gas or vapor applications on ABS
classed vessels, marine, and offshore
installations.
ABS Rules: 2013 Steel Vessels Rules 1-1-4/7.7, 1-1-A3,
4-8-3/1.7, 4-8-3/1.11.1, 4-8-3/13.1
SBV Bureau Veritas (BV) Type Approval
Certificate: 31910/A0 BV
Requirements: Bureau Veritas Rules for the Classification of
Steel Ships
Application: Class Notations: AUT-UMS, AUT-CCS,
AUT-PORT and AUT-IMS
SDN Det Norske Veritas (DNV) Type Approval
Certificate: A-13243
Intended Use: Det Norske Veritas’ Rules for Classification of
Ships, High Speed & Light Craft, and Det
Norske Veritas’ Offshore Standards
Application:
Republic of Korea Flameproof
Certificate: 12-KB4BO-0180X [Mfg USA],
11-KB4BO-0068X [Mfg Singapore]
Markings: Ex d IIC T5 or T6
Technical Regulation Customs Union (EAC)
138
KM Combination of EM and IM
Location classes
Type
Temperature
Humidity
Vibration
EMC
Enclosure
3051S
D
B
A
A
D / IP66 / IP68
SLL Lloyds Register (LR) Type Approval
Certificate: 11/60002(E3)
Application: Environmental categories ENV1, ENV2, ENV3,
and ENV5
D3
Custody Transfer – Measurement Canada Accuracy
Approval Certificate: AG-0501, AV-2380C
www.rosemount.com
October 2014
Rosemount 3051S Series
Rosemount 3051S and 3051SMV Wireless Certifications
European Directive Information
Special Conditions for Safe Use (X):
1. The model 3051SMV Wireless PDP Transmitter shall only
be used with the 701PBKKF Rosemount SmartPower
Battery Pack.
A copy of the EC Declaration of Conformity can be found at the
end of the Quick Start Guide. The most recent revision of the EC
Declaration of Conformity can be found at
www.rosemount.com.
2. The transmitter may contain more than 10% aluminum
and is considered a potential risk of ignition by impact or
friction.
Telecommunication compliance
All wireless devices require certification to ensure that they
adhere to regulations regarding the use of the RF spectrum.
Nearly every country requires this type of product certification.
Emerson is working with governmental agencies around the
world to supply fully compliant products and remove the risk of
violating country directives or laws governing wireless device
usage.
FCC and IC
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following conditions: This device may not cause
harmful interference. This device must accept any interference
received, including interference that may cause undesired
operation. This device must be installed to ensure a minimum
antenna separation distance of 20 cm from all persons.
3. The surface resistivity of the antenna is greater than 1G Ω .
To avoid electrostatic charge build-up, it must not be
rubbed or cleaned with solvents or a dry cloth.
Note
Transmitters marked with NI CL 1, DIV 2 can be installed in Division 2
locations using general Division 2 wiring methods or Nonincendive Field
Wiring (NIFW). See Drawing 03151-1000.
Canada
I6
Ordinary Location Certification from FM
Approvals
As standard, the transmitter has been examined and tested to
determine that the design meets the basic electrical,
mechanical, and fire protection requirements by FM Approvals,
a nationally recognized test laboratory (NRTL) as accredited by
the Federal Occupational Safety and Health Administration
(OSHA).
Europe
I1
North America
The US National Electrical Code (NEC) and the Canadian
Electrical Code (CEC) permit the use of Division marked
equipment in Zones and Zone marked equipment in Divisions.
The markings must be suitable for the area classification, gas,
and temperature class. This information is clearly defined in the
respective codes.
FM Intrinsic Safety (IS) and Nonincendive (NI)
Certificate: 3027705
Standards: FM Class 3600 – 2011, FM Class 3610 – 2010,
FM Class 3611 – 2004, FM Class 3810 – 2005,
NEMA 250 – 2003
Markings: IS CL 1, DIV 1, GP 1, B, C, D; CL II, DIV 1, GP E, F,
G; CL III; CL 1, ZONE 0 AEx ia IIC T4; NI CL 1,
DIV2, GPA, B, C, D, T4; DIP CL II, DIV 1, GP E, F,
G; CL III, T5; T4 (-50 °C ≤ Ta ≤ +70 °C)/
T5 (-50 °C ≤ Ta ≤ +85 °C); when connected per
Rosemount drawing 03151-1000; Type 4X
www.rosemount.com
ATEX Intrinsic Safety
Certificate: Baseefa13ATEX0127X
Standards: EN 60079-0: 2012, EN 60079-11: 2012
Markings:
II 1 G Ex ia IIC T4 Ga, T4(-60 °C ≤ Ta ≤+70 °C)
Special Conditions for Safe Use (X):
1. The Model 3051S Wireless and Model 3051SMV Wireless
enclosure may be made of aluminum alloy and given a
protective polyurethane paint finish; however, care should
be taken to protect it from impact or abrasion if located in
a zone 0 area.
United States of America
I5
CSA Intrinsically Safe
Certificate: 1143113
Standards: CAN/CSA C22.2 No. 0-10, CSA Std C22.2 No.
30-M1986, CAN/CSA C22.2 No. 94-M91, CSA
Std C22.2 No. 142-M1987, CSA Std C22.2 No.
157-92, ANSI/ISA 12.27.01-2003, CSA Std
C22.2 No. 60529:05
Markings: Intrinsically Safe Class I, Division 1; suitable for
Class 1, Zone 0, IIC, T3C; when connected per
Rosemount drawing 03151-1010; Type 4x
2. The surface resistivity of the antenna is greater than 1G Ω .
To avoid electrostatic charge build-up, it must not be
rubbed or cleaned with solvents or dry cloth.
International
I7
IECEx Intrinsic Safety
Certificate: IECEx BAS 13.0068X
Standards: IEC 60079-0: 2011, IEC 60079-11: 2011
Markings: Ex ia IIC T4 Ga, T4(-60 °C ≤ Ta ≤ +70 °C)
139
Rosemount 3051S Series
October 2014
Special Conditions for Safe Use (X):
1. The Model 3051S Wireless and Model 3051SMV Wireless
enclosure may be made of aluminum alloy and given a
protective polyurethane paint finish; however, care should
be taken to protect it from impact or abrasion if located in
a zone 0 area.
2. The surface resistivity of the antenna is greater than 1G Ω .
To avoid electrostatic charge build-up, it must not be
rubbed or cleaned with solvents or dry cloth.
Brazil
I2
INMETRO Intrinsic Safety
Certificate: CEPEL 08.1618
Standards: ABNT NBR IEC60079-0:2008, ABNT NBR
IEC60079-11:2009, ABNT NBR IEC
60079-26:2008, ABNT NBR IEC 60529:2009
Markings: Ex ia IIC T5/T4 Ga, T5(-60 °C ≤ Ta ≤ +40 °C),
T4(-60 °C ≤ Ta ≤ +70 °C), IP66(Al)/IP66W(SST)
Note
Not currently available on the 3051S MultiVariable Wireless Transmitter.
China
I3
China Intrinsic Safety
Certificate: 3051S Wireless: GYJ111401X 3051SFX:
GYJ11.1707X [Flowmeters]
Standards: GB3836.1-2010, GB3836.4-2010,
GB3836.20-2010, GB12476.1-2000
Markings: Ex ia IIC T4(-50 °C~+70 °C)
Special Condition for Safe Use (X):
1. See appropriate certificate.
Note
Not currently available on the 3051S MultiVariable Wireless Transmitter.
Japan
I4
TIIS Intrinsically Safe
Certificate: TC18649, TC18650, TC18657
Markings: Ex ia IIC T4, T4 -20 ~ 60 °C
Note
Not currently available on the 3051S MultiVariable Wireless Transmitter.
Republic of Korea
IP
Contact an Emerson Process Management representative
for additional information
Technical Regulation Customs Union (EAC)
IM Contact an Emerson Process Management representative
for additional information.
140
www.rosemount.com
October 2014
Rosemount 3051S Series
Rosemount 3051SMV/3051SFx (Measurement Type 1-7)
Certifications
European Directive Information
Canada
A copy of the EC Declaration of Conformity can be found at the
end of the Quick Start Guide. The most recent revision of the EC
Declaration of Conformity can be found at
www.rosemount.com.
E6
CSA Explosionproof, Dust-Ignitionproof, and Division 2
Certificate: 1143113
Standards: CAN/CSA C22.2 No. 0-10, CSA Std C22.2 No.
25-1966, CSA Std C22.2 No. 30-M1986,
CAN/CSA C22.2 No. 94-M91, CSA Std C22.2
No. 142-M1987, CSA Std C22.2 No.
213-M1987, ANSI/ISA 12.27.01-2003, CSA
Std C22.2 No. 60529:05
Markings: Explosionproof Class I, Division 1, Groups B, C,
D; Dust-Ignitionproof Class II, Division 1,
Groups E, F, G; Class III; suitable for Class I,
Division 2, Groups A, B, C, D; Type 4x
I6
CSA Intrinsically Safe
Certificate: 1143113
Standards: CAN/CSA C22.2 No. 0-10, CSA Std C22.2 No.
30-M1986, CAN/CSA C22.2 No. 94-M91, CSA
Std C22.2 No. 142-M1987, CSA Std C22.2 No.
157-92, ANSI/ISA 12.27.01-2003, CSA Std
C22.2 No. 60529:05
Markings: Intrinsically Safe Class I, Division 1; suitable for
Class 1, Zone 0, IIC, T3C; when connected per
Rosemount drawing 03151-1207; Type 4x
Ordinary Location Certification from FM
Approvals
As standard, the transmitter has been examined and tested to
determine that the design meets the basic electrical,
mechanical, and fire protection requirements by FM Approvals,
a nationally recognized test laboratory (NRTL) as accredited by
the Federal Occupational Safety and Health Administration
(OSHA).
North America
The US National Electrical Code (NEC) and the Canadian
Electrical Code (CEC) permit the use of Division marked
equipment in Zones and Zone marked equipment in Divisions.
The markings must be suitable for the area classification, gas,
and temperature class. This information is clearly defined in the
respective codes.
United States of America
E5
I5
FM Explosionproof (XP) and Dust-Ignitionproof (DIP)
Certificate: 3008216
Standards:FM Class 3600 – 2011, FM Class 3615 – 2006,
FM Class 3616-2011, 3810 – 2005, ANSI/NEMA
250 – 2003
Markings: XP CL I, DIV 1, GP B, C, D; DIP CL II, DIV 1, GP E, F,
G; CL III; T5(-50°C ≤ Ta ≤ +85°C); Factory Sealed;
Type 4X
FM Intrinsic Safety (IS) and Nonincendive (NI)
Certificate: 3031960
Standards: FM Class 3600 – 1998, FM Class 3610 – 2007,
FM Class 3611 – 2004, FM Class 3810 – 2005,
NEMA 250 – 1991
Markings: IS CL I, DIV 1, GP A, B, C, D; CL II, DIV 1, GP E, F,
G; Class III; Class 1, Zone 0 AEx ia IIC T4; NI CL 1,
DIV 2, GP A, B, C, D; T4(-50°C ≤ Ta ≤ +70°C)
when connected per Rosemount drawing
03151-1206; Type 4x
Note
Transmitters marked with NI CL 1, DIV 2 can be installed in Division 2
locations using general Division 2 wiring methods or Nonincendive Field
Wiring (NIFW). See Drawing 03151-1206.
Europe
E1
ATEX Flameproof
Certificate: KEMA 00ATEX2143X
Standards: EN 60079-0:2012, EN 60079-1: 2007, EN
60079-26:2007
Markings: II 1/2 G Ex d IIC T6…T4 Ga/Gb, T6(-60 °C ≤ Ta ≤
+70 °C), T5/T4(-60 °C ≤ Ta ≤ +80 °C)
Temperature class Process temperature
T6
-60 °C to +70 °C
T5
-60 °C to +80 °C
T4
-60 °C to +120 °C
Special Conditions for Safe Use (X):
1. The device contains a thin wall diaphragm. Installation,
maintenance and use shall take into account the
environmental conditions to which the diaphragm will be
subjected. The manufacturer’s instructions for installation
and maintenance shall be followed in detail to assure
safety during its expected lifetime.
2. For information on the dimensions of the flameproof joints
the manufacturer shall be contacted.
www.rosemount.com
141
Rosemount 3051S Series
I1
October 2014
ATEX Intrinsic Safety
Certificate: Baseefa08ATEX0064X
Standards: EN 60079-0: 2012, EN 60079-11: 2012
Markings:
II 1 G Ex ia IIC T4 Ga, T4(-60 °C ≤ Ta ≤ +70 °C)
International
E7
IECEx Flameproof and Dust
Certificate: IECEx KEM 08.0010X (Flameproof)
Standards: IEC 60079-0:2011, IEC 60079-1: 2007, IEC
60079-26:2006
Markings: Ex d IIC T6…T4 Ga/Gb, T6(-60 °C ≤ Ta ≤ +70 °C),
T5/T4(-60 °C ≤ Ta ≤ +80 °C)
HART
SuperModule
only
RTD (for
3051SFx)
Voltage Ui
30 V
7.14 V
30 V
Current Ii
300 mA
300 mA
2.31 mA
Power Pi
1W
887 mW
17.32 mW
Capacitance Ci
12 nF
0.11 μF
30
T6
-60 °C to +70 °C
Inductance Li
0
0
0
T5
-60 °C to +80 °C
T4
-60 °C to +120 °C
Temperature Process
class
temperature
Special Conditions for Safe Use (X):
1. If the equipment is fitted with the optional 90V transient
suppressor, it is incapable of withstanding the 500V
isolation from earth test and this must be taken into
account during installation
Special Conditions for Safe Use (X):
1. The device contains a thin wall diaphragm. Installation,
maintenance and use shall take into account the
environmental conditions to which the diaphragm will be
subjected. The manufacturer’s instructions for installation
and maintenance shall be followed in detail to assure
safety during its expected lifetime.
2. The enclosure may be made of aluminum alloy and given a
protective polyurethane paint finish; however, care should
be taken to protect it from impact or abrasion if located in
a Zone 0 environment.
2. For information on the dimensions of the flameproof joints
the manufacturer shall be contacted.
ND ATEX Dust
Certificate: BAS01ATEX1374X
Standards: EN 60079-0: 2012, EN 60079-31: 2009
Markings:
II 1 D Ex ta IIIC T105°C T50095 °C Da,
(-20 °C ≤ Ta ≤ +85 °C), Vmax = 42.4V
Special Conditions for Safe Use (X):
Certificate: IECEx BAS 09.0014X (Dust)
Standards: IEC 60079-0:2011, IEC 60079-31:2008
Markings: Ex ta IIIC T105 °C T50095 °C Da,
(-20 °C ≤ Ta ≤ +85 °C), Vmax = 42.4V
Special Conditions for Safe Use (X):
1. Cable entries must be used which maintain the ingress
protection of the enclosure to at least IP66.
1. Cable entries must be used which maintain the ingress
protection of the enclosure to at least IP66.
2. Unused cable entries must be filled with suitable blanking
plugs which maintain the ingress protection of the
enclosure to at least IP66.
2. Unused cable entries must be filled with suitable blanking
plugs which maintain the ingress protection of the
enclosure to at least IP66.
3. Cable entries and blanking plugs must be suitable for the
ambient temperature range of the apparatus and capable
of withstanding a 7J impact test.
3. Cable entries and blanking plugs must be suitable for the
ambient temperature range of the apparatus and capable
of withstanding a 7J impact test.
4. The SuperModule(s) must be securely screwed in place to
maintain the ingress protection of the enclosure(s).
N1
ATEX Type n
Certificate: Baseefa08ATEX0065X
Standards: EN 60079-0: 2012, EN 60079-15: 2010
Markings:
II 3 G Ex nA IIC T4 Gc, (-40 °C ≤ Ta ≤ 70 °C),
Vmax = 45V
4. The 3051S- SuperModule must be securely screwed in
place to maintain the ingress protection of the enclosure.
I7
IECEx Intrinsic Safety
Certificate: IECEx BAS 08.0025X
Standards: IEC 60079-0: 2011, IEC 60079-11: 2011
Markings: Ex ia IIC T4 Ga, T4(-60 °C ≤ Ta ≤ +70 °C)
HART
Special Condition for Safe Use (X):
1. If fitted with a 90V transient suppressor, the equipment is
not capable of withstanding the 500V electrical strength
test as defined in Clause 6.5.1 of EN 60079-15:2010. This
must be taken into account during installation.
142
SuperModule
only
RTD (for
3051SFx)
Voltage Ui
30 V
7.14 V
30 V
Current Ii
300 mA
300 mA
2.31 mA
Power Pi
1W
887 mW
17.32 mW
Capacitance Ci
12 nF
0.11 μ F
0
Inductance Li
0
0
0
www.rosemount.com
October 2014
Rosemount 3051S Series
2. For processes with temperatures above 135 °C, the user
must assess whether the SuperModule temperature class
is suitable for such applications, because in this situation
there is a risk of the SuperModule temperature being
above T4.
Special Conditions for Safe Use (X):
1. If the equipment is fitted with the optional 90V transient
suppressor, it is incapable of withstanding the 500V
isolation from earth test and this must be taken into
account during installation.
2. The enclosure may be made of aluminum alloy and given a
protective polyurethane paint finish; however, care should
be taken to protect it from impact or abrasion if located in
a Zone 0 environment.
N7
IECEx Type n
Certificate: IECEx BAS 08.0026X
Standards: IEC 60079-0: 2011, IEC 60079-15: 2010
Markings: Ex nA IIC T5 Gc, (-40 °C ≤ Ta ≤ 70 °C)
Special Condition for Safe Use (X):
1. If fitted with a 90V transient suppressor, the equipment is
not capable of withstanding the 500V electrical strength
test as defined in Clause 6.5.1 of IEC 60079-15:2010. This
must be taken into account during installation.
HART
SuperModule
only
RTD (for
3051SFx)
Voltage Ui
30 V
7.14 V
30 V
Current Ii
300 mA
300 mA
2.31 mA
Power Pi
1W
887 mW
17.32 mW
Capacitance Ci
12 nF
0.11 μ F
0
Inductance Li
0
0
0
China
E3
China Flameproof and Dust Ignition-proof
Certificate: 3051SMV: GYJ14.1039X [Mfg USA, China,
Singapore] 3051SFx: GYJ071086 [Mfg USA,
China, Singapore]
Standards: 3051SMV: GB3836.1-2010, GB3836.2-2010,
GB3836.20-2010
3051SFx: GB3836.1-2000, GB3836.2-2000,
GB12476.1-2000
Markings: 3051SMV: Ex d IIC T6/T5 Ga/Gb
3051SFx: Ex d IIC T6/T5; Ex d IIB+H2T3~T5; DIP
A21 TA T3~T5
I3
China Intrinsic Safety
Certificate: 3051SMV: GYJ14.1040X [Mfg USA, China,
Singapore]
3051SFx: GYJ11.1707X [Mfg USA, China,
Singapore]
Standards: 3051SMV: GB3836.1-2010, GB3836.4-2010,
GB3836.20-2010
3051SFx: GB3836.1/4-2010, GB3836.20-2010,
GB12476.1-2000
Markings: 3051SMV: Ex ia IIC T4 Ga
3051SFx: Ex ia IIC T4 Ga, DIP A20 TA105°C IP66
Brazil
E2
INMETRO Flameproof
Certificate: CEPEL 03.0140X [Mfg USA, Singapore,
Germany], CEPEL 07.1413X [Mfg Brazil]
Standards: ABNT NBR IEC 60079-0:2008, ABNT NBR IEC
60079-1:2009, ABNT NBR IEC 60529:2009
Markings: Ex d IIC T* Ga/Gb, T6(-40 °C ≤ Ta ≤ +65 °C),
T5(-40 °C ≤ Ta ≤ +80 °C), IP66(Al)/IP66W(SST)
Special Conditions for Safe Use (X):
1. For ambient temperature above 60 °C, cable wiring must
have minimum isolation temperature of 90 °C, to be in
accordance to equipment operation temperature.
2. The device contains a thin wall diaphragm. Installation,
maintenance and use shall take into account the
environmental conditions to which the diaphragm will be
subjected. The manufacturer’s instructions for installation
and maintenance shall be followed in detail to assure
safety during its expected lifetime.
I2
INMETRO Intrinsic Safety
Certificate:NCC 12.1158X [Mfg USA, Germany]
Standards: ABNT NBR IEC 60079-0:2008, ABNT NBR IEC
60079-11:2009, ABNT NBR IEC 60079-26:2008
Markings: Ex ia IIC T4 Ga, T4(-60 °C ≤ Ta ≤ +70 °C),
IP66(Al)/IP66W(SST)
Special Conditions for Safe Use (X):
Japan
E4
Japan Flameproof
Certificate:TC19070, TC19071, TC19072, TC19073
Markings: Ex d IIC T6
Technical Regulation Customs Union (EAC)
EM, IM, KM Contact an Emerson Process Management
representative for additional information.
1. If the equipment is fitted with the optional 90V transient
suppressor, it is incapable of withstanding the 500V
isolation from earth test and this must be taken into
account during installation.
www.rosemount.com
143
Rosemount 3051S Series
October 2014
Combinations
K1
Combination of E1, I1, N1, and ND
K2
Combination of E2 and I2
K5
Combination of E5 and I5
K6
Combination of E6 and I6
K7
Combination of E7, I7, and N7
KA
Combination of E1, I1, E6, and I6
KB
Combination of E5, I5, E6, and I6
KC
Combination of E1, I1, E5, and I5
KD
Combination of E1, I1, E5, I5, E6, and I6
Additional Certifications
SBS American Bureau of Shipping (ABS) Type Approval
Certificate: 00-HS145383-6-PDA
Intended Use: Measure gauge or absolute pressure of
liquid, gas or vapor applications on ABS
classed vessels, marine, and offshore
installations.
ABS Rules: 2013 Steel Vessels Rules 1-1-4/7.7, 1-1-A3,
4-8-3/1.7, 4-8-3/1.11.1, 4-8-3/13.1
D3
144
Custody Transfer – Measurement Canada Accuracy
Approval Certificate: AG-0501, AV-2380C
www.rosemount.com
October 2014
Rosemount 3051S Series
Dimensional Drawings
Figure 1. Transmitter with Coplanar Sensor Module and Flange
PlantWeb Housing
Junction Box Housing
Wireless Housing
Front view
Front view
Front view
4.20
4.20
(107)
Extended Range
External Antenna
4.20
4.20
(107)
(107)
(107)
External
Antenna
8.53
8.57
(217)
(217)
8.53
8.57
(217)
(217)
6.88
(174)
90°
11.16
(283)
4.20
(107)
9.63
9.63
9.67
(245)
(245)
9.67
(245)
(245)
Side view
Side view
Side view
3.45 (88)
4.51
4.55
(114)
(116)
3.55
(90.1)
6.71
(170)
6.05
(153)
7.72
(196)
8.57
(217)
9.67
(245)
6.55
6.44
(166)
(164)
6.55 (166)
6.55
(166)
Dimensions are in inches (millimeters).
www.rosemount.com
145
Rosemount 3051S Series
October 2014
Figure 2. Transmitter with Coplanar Sensor Module and Traditional Flange
PlantWeb Housing
Junction Box Housing
Wireless Housing
Front view
Front view
Front view
Extended Range
External Antenna
External
Antenna
6.88
(174)
9.30
(236)
9.30
(236)
3.40
(86)
1.10
(28)
Side view
4.20
(107)
3.40
(86)
1.10
(28)
3.40
(86)
Side view
90°
11.16
(283)
7.81
(198)
1.10
(28)
Side view
3.45 (88)
3.55
(90.1)
6.71
(170)
6.05
(155)
7.72
(196)
9.30
(236)
1.63 (41)
1.63 (41)
2.13 (54)
2.13
(54)
Dimensions are in inches (millimeters).
146
www.rosemount.com
October 2014
Rosemount 3051S Series
Figure 3. Transmitter with In-Line Sensor Module (for ranges 1A-4A, 1/2” NPT 316L SST process wetted
connection). For detailed dimensions on other configurations, see Type I drawings at rosemount.com.
PlantWeb Housing
Junction Box Housing
Wireless Housing
Front view
Front view
Front view
Extended Range
External Antenna
4.20
(107)
4.20
(107)
External
Antenna
6.88
(174)
3.55
(90.1)
11.16
(283)
4.20
(107
8.04
(204)
8.04
(204)
Side view
Side view
5.17
(131)
5.21 (132)
3.45
(88)
4.55 (116)
4.51
(114)
90°
Side view
6.88
(174)
6.71
(170)
6.05
(155)
8.19
(208)
Dimensions are in inches (millimeters).
www.rosemount.com
147
Rosemount 3051S Series
October 2014
Figure 4. PlantWeb Housing, Junction Box Housing, and Quick Connect with In-Line SuperModule Platform
4.55
(116)
4.20
(107)
3.45
(88)
1.50
(38)
2.57
(65)
7.97
(202)
8.04
(204)
6.22
(158)
1.37
(35)
I-Flange
Process
Connector
2.40
(61)
Dimensions are in inches (millimeters).
148
www.rosemount.com
October 2014
Rosemount 3051S Series
Figure 5. High Gain, Remote Mount Antenna (WN option)
Dimensions are in inches (millimeters).
www.rosemount.com
149
Rosemount 3051S Series
October 2014
Figure 6. Coplanar Mounting Configurations (B4 Bracket)
Pipe Mount
Panel Mount
Front view
Front view
Front view
2.60
2.58
(66)
(66)
4.51
4.55
(114)
(116)
6.15
6.15
(156)
(156)
2.81
2.81
(71)
(71)
3.54
3.54
(90)
(90)
4.73
4.72
(120)
(120)
6.25
6.25
(159)
(159)
Dimensions are in inches (millimeters).
Figure 7. Traditional Mounting Configurations
Pipe Mount
Pipe Mount (Flat Bracket)
Panel Mount
10.71 (272)
2.62
(67)
8.10
(205)
8.10
(205)
0.93
(24)
2.62
(67)
3.40
(86)
3.40
(86)
4.85
(123)
7.70 (196)
Dimensions are in inches (millimeters).
150
www.rosemount.com
October 2014
Rosemount 3051S Series
Figure 8. In-Line Mounting Configurations (B4 Bracket)
Pipe Mount
Front view
Panel Mount
Side view
Side view
2.59
(65)
4.51 (114)
6.15
(156)
6.15
2.81
(71)
6.25
(159)
3.08
(78)
4.72 (120)
Dimensions are in inches (millimeters).
Figure 9. Remote Display Mounting Configurations (B4 Bracket)
Pipe Mount
Front view
Panel Mount
Side view
Side view
2.34
(59)
5.17 (131)
4.48
(114
2.66
(68)
2.66
(68)
8.72 (221)
6.15
(156)
4.72 (120)
3.08
(78)
6.25 (158)
Dimensions are in inches (millimeters).
www.rosemount.com
151
Rosemount 3051S Series
October 2014
Figure 10. Rosemount 3051SFA Annubar Flowmeter
Rosemount 3051SFA Annubar Flowmeter(1)
Front view
Side view
Top view
D
C
B
A
(1) The Pak-Lok Annubar model is available up to 600# ANSI [1440 psig at 100 °F (99 bar at 38 °C)].
Table 22. 3051CFA Annubar Flowmeter Dimensional Data
Sensor size
A (Max)
B (Max)
C (Max)
D (Max)
1
8.50(215.9)
17.10 (434.3)
8.66 (220.0)
7.00 (177.8)
2
11.00(279.4)
19.60 (497.8)
8.66 (220.0)
7.00 (177.8)
3
12.00 (304.8)
20.60 (523.2)
8.66 (220.0)
7.00 (177.8)
Dimensions are in inches (millimeters)
152
www.rosemount.com
October 2014
Rosemount 3051S Series
Figure 11. Rosemount 3051SFC Compact Orifice Flowmeter
Rosemount 3051SFC Compact Orifice Flowmeter
Orifice plate front view
Orifice plate side view
E
C
D
primary element type code A
Orifice plate top view
B
A
1.125 (28.58)
primary element type code C and P
E
D
B
A
C
F
1.125 (28.58)
Dimensions are in inches (millimeters).
www.rosemount.com
153
Rosemount 3051S Series
October 2014
Table 23. Dimensional Drawings
Primary
element
type
A
B
Transmitter
height
Type A
5.62
(143)
Transmitter
Height + A
8.53 (217)
7.75 (197) - closed 6.00 (152) - closed 10.0 (254) - closed
8.25 (210) - open 6.25 (159) - open 10.25 (260.3) - open
Type P and C
5.62
(143)
Transmitter
Height + A
7.70 (196)
7.75 (197) - closed 6.00 (152) - closed 10.2 (257.8) - closed Max of
8.25 (210) - open 6.25 (159) - open 10.4 (264.2) - open 7.2 (184)
C
D
E
F
-
Dimensions are in inches (millimeters).
154
www.rosemount.com
October 2014
Rosemount 3051S Series
Figure 12. Rosemount 3051SFP Integral Orifice Flowmeter
Rosemount 3051SFP Integral Orifice Flowmeter
Front view
Bottom view
Side view
11.73
(297,9)
8.8 (223.46)
7.7 (195.6)
Flow
5.3
(134.14)
B.D.
K(1) Downstream
J Upstream
Dimensions are in inches (millimeters).
Line size
Dimension
J (Beveled/Threaded pipe ends)
J (RF slip-on, RTJ slip-on, RF-DIN slip on)
J (RF 150#, weld neck)
J (RF 300#, weld neck)
J (RF 600#, weld neck)
K (Beveled/Threaded pipe ends)
K (RF slip-on, RTJ slip-on, RF-DIN slip on)(1)
K (RF 150#, weld neck)
K (RF 300#, weld neck)
1
/2-in. (15 mm)
1-in. (25 mm)
11/2-in. (40 mm)
12.54 (318.4)
12.62 (320.4)
14.37 (364.9)
14.56 (369.8)
14.81 (376.0)
5.74 (145.7)
5.82 (147.8)
7.57 (192.3)
7.76 (197.1)
20.24 (514.0)
20.32 (516.0)
22.37 (568.1)
22.63 (574.7)
22.88 (581.0)
8.75 (222.2)
8.83 (224.2)
10.88 (276.3)
11.14 (282.9)
28.44 (722.4)
28.52 (724.4)
30.82 (782.9)
31.06 (789.0)
31.38 (797.1)
11.91 (302.6)
11.99 (304.6)
14.29 (363.1)
14.53 (369.2)
(1) Downstream length shown here includes plate thickness of 0.162-in. (4.11 mm).
www.rosemount.com
155
Rosemount 3051S Series
October 2014
Figure 13. Rosemount 3051S Scalable Level Transmitter with FF Seal
Rosemount 3051S Scalable Level Transmitter with FF(1)(2)- Coplanar Style
5.17
(131)
4.51
(114)
8.57
(217,7)
+ Direct Mount
Extension Length
Rosemount 3051S Scalable Level Transmitter with FF(1)(2) - In-Line Style
5.17
(131)
8.04
(204)
Dimensions are in inches (millimeters).
(1) FF (FFW) seal dimensions and pressure ratings can be found in the Rosemount DP Level Transmitters and 1199 Remote Seals Product Data Sheet,
(00813-0100-4016).
(2) Lower housing (flushing ring) is available with FFW style flange.
156
www.rosemount.com
October 2014
Rosemount 3051S Series
Figure 14. Rosemount 3051S Scalable Level Transmitter with Thermal Range Expander
Rosemount 3051S Scalable Level Transmitter with Thermal Range Expander – Coplanar Style
Rosemount 3051S Scalable Level Transmitter with Thermal Range Expander – In-Line Style
Dimensions are in inches (millimeters).
www.rosemount.com
157
Rosemount 3051S Series
October 2014
Figure 15. Rosemount 3051S Scalable Level Transmitter with EF Seal
Rosemount 3051S Scalable Level Transmitter with EF(1)- Coplanar Style
5.17
(131)
4.51
(114)
8.57
(217.7)
+ Direct Mount
Extension Length
Rosemount 3051S Scalable Level Transmitter with EF(1) - In-Line Style
5.17
(131)
8.04
(204)
Dimensions are in inches (millimeters).
(1) EF (EFW) seal dimensions and pressure ratings can be found in the Rosemount DP Level Transmitters and 1199 Remote Seals Product Data Sheet,
(00813-0100-4016).
158
www.rosemount.com
October 2014
Rosemount 3051S Series
Figure 16. Rosemount 3051S Scalable Level Transmitter with RF Seal
Rosemount 3051S Scalable Level Transmitter with RF(1)- Coplanar Style
5.17
(131)
4.51
(114)
8.57
(217.7)
+ Direct Mount
Extension Length
Rosemount 3051S Scalable Level Transmitter with RF(1) - In-Line Style
5.17
(131)
8.04
(204)
Dimensions are in inches (millimeters).
(1) RF (RFW) seal dimensions and pressure ratings can be found in the Rosemount DP Level Transmitters and 1199 Remote Seals Product Data Sheet,
(00813-0100-4016).
www.rosemount.com
159
Rosemount 3051S Series
October 2014
Figure 17. Rosemount 3051S Scalable Level Transmitter with RT Seal
Rosemount 3051S Scalable Level Transmitter with RT(1)- Coplanar Style
5.17
(131)
4.51
(114)
8.57
(217)
+ Direct Mount
Extension Length
Rosemount 3051S Scalable Level Transmitter with RT(1) - In-Line Style
4.51
(114)
8.04
(204)
Dimensions are in inches (millimeters).
(1) RT (RTW) seal dimensions can be found in the Rosemount DP Level Transmitters and 1199 Remote Seals Product Data Sheet, (00813-0100-4016).
160
www.rosemount.com
October 2014
Rosemount 3051S Series
Figure 18. Rosemount 3051S Scalable Level Transmitter with SS Seal
Rosemount 3051S Scalable Level Transmitter with SS(1)- Coplanar Style
5.17
(131)
4.51
(114)
8.57
(217.7)
+ Direct Mount
Extension Length
Rosemount 3051S Scalable Level Transmitter with SS(1) - In-Line Style
5.17
(131)
8.04
(204)
Dimensions are in inches (millimeters).
(1) SS (SSW) seal dimensions and pressure ratings can be found in the Rosemount DP Level Transmitters and 1199 Remote Seals Product Data Sheet,
(00813-0100-4016).
www.rosemount.com
161
Rosemount 3051S Series
October 2014
Figure 19. Rosemount 3051S Scalable Level Transmitter with SC Seal
Rosemount 3051S Scalable Level Transmitter with SC(1)- Coplanar Style
5.17
(131)
4.51
(114)
8.57
(217.7)
+ Direct Mount
Extension Length
Rosemount 3051S Scalable Level Transmitter with SC(1) - In-Line Style
5.17
(131)
8.04
(204)
Dimensions are in inches (millimeters).
(1) SC (SCW) seal dimensions and pressure ratings can be found in the Rosemount DP Level Transmitters and 1199 Remote Seals Product Data Sheet,
(00813-0100-4016).
162
www.rosemount.com
October 2014
Rosemount 3051S Series
Accessories
Engineering Assistant software packages
Rosemount Engineering Assistant (EA)
software packages
Code Product description
The Rosemount Engineering Assistant software supports flow
configuration for the 3051S MultiVariable and 3051S
FOUNDATION fieldbus Fully Compensated Mass Flow Block (H01
option). The package is available with or without modem and
connecting cables. All configurations are packaged separately.
For best performance of the EA Software, the following
computer hardware and software is recommended:
Note
Engineering Assistant version 6.1 or later requires the use
of Microsoft®.NET Framework version 2.0 or later. If.NET
version 2.0 is not currently installed, the software will be
automatically installed during the Engineering Assistant
installation. Microsoft.NET version 2.0 requires an
additional 200 MB of disk space.
Minimum system requirements for Engineering
Assistant 5.5.1 for the 3051S FOUNDATION fieldbus
with fully compensated mass flow block (H01
option)
EA
Engineering Assistant Software Program
Code Software media
2
EA Rev. 5 (Compatible with 3095, 3051S FOUNDATION
fieldbus, and 333)
3
EA Rev. 6 (Compatible with 3051SMV only)
Code Language
E
English
Code Modem and connecting cables
0
None
H
Serial Port HART Modem and Cables
B
USB Port HART Modem and Cables
C
FOUNDATION fieldbus PCM-CIA Interface Card and Cables
Code License
N1
Single PC license
N2
Site license
Typical model number:
EA
2
E
0
N1

PC Compatible Pentium 400 or above

Operating System: Windows™ XP Professional (32-bit) or
Windows Vista (32-bit)

256 MB RAM

535 MB free hard disk space

RS232 serial port or USB port (for use with HART modem)
USB Port HART Modem and Cables
Only(1)
03095-5105-0002

CD-ROM
FOUNDATION fieldbus PCM-CIA Interface
Card and Cables Only
03095-5108-0001
Long-life Power Module for Wireless
option
701PBKKF
Minimum system requirements for Engineering
Assistant 6 for the 3051SMV

Pentium-grade Processor: 500MHz or faster

Operating System: Microsoft Windows 2000 (32-bit),
Windows XP Professional (32-bit), or Windows 7

256 MB RAM

100 MB of available hard disk space

RS232 serial port or USB port (for use with HART modem)

CD-ROM
www.rosemount.com
Accessories
Item description
Part number
Serial Port HART Modem and Cables Only 03095-5105-0001
(1) Supported by SNAP-ON™ EA with AMS Device Manager version 6.2 or
higher.
163
Rosemount 3051S Series
Product Data Sheet
00813-0100-4801, Rev TA
Emerson Process Management
Rosemount Inc.
8200 Market Boulevard
Chanhassen, MN 55317 USA
T (U.S.) 1-800-999-9307
T (International) (952) 906-8888
F (952) 906 8889
www.rosemount.com
Emerson Process Management Asia
Pacific Pte Ltd
1 Pandan Crescent
Singapore 128461
Tel +65 6777 8211
Fax +65 6777 0947
Service Support Hotline : +65 6770 8711
Email : [email protected]
October 2014
Emerson Process Management
Latin America
1300 Concord Terrace, Suite 400
Sunrise, Florida 33323 USA
Tel + 1 954 846 5030
Emerson Process Management
Blegistrasse 23
P.O. Box 1046
CH 6341 Baar
Switzerland
Tel +41 (0) 41 768 6111
Fax +41 (0) 41 768 6300
Emerson FZE
P.O. Box 17033
Jebel Ali Free Zone
Dubai UAE
Tel +971 4 811 8100
Fax +971 4 886 5465
Standard Terms and Conditions of Sale can be found at www.rosemount.com\terms_of_sale.
The Emerson logo is a trade mark and service mark of Emerson Electric Co.
Annubar, Coplanar, ERS, Instrument Toolkit, MultiVariable, Saturn, Scalable, SmartPower, SuperModule, THUM Adapter, Tri-Clamp, Tuned-System,
Rosemount, and the Rosemount logotype are registered trademarks of Rosemount Inc.
PlantWeb and SNAP-ON are registered trademarks of one of the Emerson Process Management group of companies.
HART and WirelessHART are registered trademarks of the HART Communication Foundation.
FOUNDATION fieldbus is a trademark of the Fieldbus Foundation.
eurofast and minifast are registered trademarks of TURCK.
Microsoft and Windows are registered trademarks of Microsoft Corporation in the United States and other countries.
SYLTHERM is a trademark of Dow Corning Corporation.
Neobee is a registered trademark of Stepan Specialty Products, LLC.
NEMA is a registered trademark and service mark of the National Electrical Manufacturers Association.
GRAFOIL is a registered trademark of GrafTech International Holdings Inc.
All other marks are the property of their respective owners.
© 2014 Rosemount Inc. All rights reserved.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement