Complimentary Reference Material This PDF has been made available as a complimentary service for you to assist in evaluating this model for your testing requirements. TMG offers a wide range of test equipment solutions, from renting short to long term, buying refurbished and purchasing new. Financing options, such as Financial Rental, and Leasing are also available on application. TMG will assist if you are unsure whether this model will suit your requirements. Call TMG if you need to organise repair and/or calibrate your unit. If you click on the “Click-to-Call” logo below, you can all us for FREE! TMG Corporate Website TMG Products Website Disclaimer: All trademarks appearing within this PDF are trademarks of their respective owners. Form 080/01 Audio Analyzer R&SUPV Preliminary Specifications ANALOG ANALYZERS.....................................................................................................................................................................................3 INPUTS ............................................................................................................................................................................................................3 MEASUREMENT FUNCTIONS .............................................................................................................................................................................3 ANALOG GENERATORS .................................................................................................................................................................................5 OUTPUTS .........................................................................................................................................................................................................5 SIGNALS ..........................................................................................................................................................................................................5 DIGITAL ANALYZERS......................................................................................................................................................................................7 DIGITAL AUDIO INPUTS (OPTION R&S UPV-B2)...............................................................................................................................................7 I2S INPUT (OPTION R&S UPV-B41) ................................................................................................................................................................7 MEASUREMENT FUNCTIONS .............................................................................................................................................................................8 DIGITAL GENERATORS ..................................................................................................................................................................................9 DIGITAL AUDIO OUTPUTS (O PTION R&S UPV-B2) ...........................................................................................................................................9 I2S OUTPUT (OPTION R&S UPV-B41) ............................................................................................................................................................9 SIGNALS ........................................................................................................................................................................................................10 FFT ANALYZER ..............................................................................................................................................................................................11 FILTER .............................................................................................................................................................................................................11 SWEEP .............................................................................................................................................................................................................12 DISPLAY OF RESULTS..................................................................................................................................................................................12 AUDIO MONITOR ............................................................................................................................................................................................13 MODIFICATION R&S UPV-U1........................................................................................................................................................................13 GENERAL DATA .............................................................................................................................................................................................13 ORDERING INFORMATION ...........................................................................................................................................................................14 2 ® R&S UPV Version 01.00, October 2004 Analog analyzers Analog measurements are available with four different bandwidths, specifications and measurement functions. Analyzer Frequency range Bandwidth 22 kHz Bandwidth 40/80 kHz Bandwidth 250 kHz DC/10 Hz to 21.76 kHz1 DC/10 Hz to 40/80 kHz1 DC/10 Hz to 250 kHz1 Level measurements (rms) Accuracy Frequency response (ref. to 1 kHz) at 1 kHz 20 Hz to 20 kHz 20 kHz to 50 kHz 50 kHz to 100 kHz 100 kHz to 250 kHz ±0.05 dB, typ. ±0.025 dB ±0.01 dB, typ. 0.003 dB (Vin <3 V) 2 20 Hz to 50 Hz: add −0.06 dB ±0.03 dB (Vin <3 V)2 ±0.1 dB ±0.3 dB Inputs XLR connectors Voltage range Measurement ranges Input impedance Crosstalk attenuation Common-mode rejection (Vin <3 V) Generator output 2 channels, balanced (unbalanced measurements possible with XLR/BNC Adapter R&S UPL-Z1), floating/grounded and AC/DC coupling switchable 0.1 µV to 110 V (rms, sine) 18 mV to 100 V, in steps of 5 dB 100 kΩ ±1 % shunted by 120 pF (230 pF for ≥ 6 V ranges), each pin against ground. 300 Ω ±0.5 %, Pmax 2 W 600 Ω ±0.5 %, Pmax 1 W frequency <22 kHz, 600 Ω >120 dB at 50 Hz >90 dB at 1 kHz >86 dB at 20 kHz >80 dB each input channel switchable to any output channel, input impedance: balanced 200 kΩ, unbalanced 100 kΩ Measurement functions RMS value, wideband Accuracy Integration time Noise (input shorted) Spectrum DC voltage Voltage range Accuracy Measurement ranges FFT analysis Measurement speed AUTO Measurement speed AUTO FAST AUTO FAST/AUTO GEN TRACK VALUE 22/40/80 kHz bandwidth A weighted CCIR unweighted ±0.05 dB, typ. ±0.025 dB, at 1 kHz, sine ±0.1 dB additional error 200/4000 samples min., at least 1 cycle 100 samples min., at least 1 cycle 0.1 ms to 10 s 80 kHz bandwidth 250 kHz bandwidth post-FFT <2.8 µV <7 µV 0 V to ±110 V ±(1% of measured value + 0.1% of measurement range) 100 mV to 100 V, in steps of 10 dB see FFT analyzer section 1 DC/AC coupling 2 Vin ≥ 3 V additional ±0.02 dB from 5 kHz to 50 kHz Version 01.00, October 2004 <1 µV, 0.7 µV typ. <1.4 µV, 1 µV typ. ® R&S UPV 3 Total harmonic distortion (THD) Fundamental Frequency tuning Weighted harmonics Accuracy Inherent distortion Bandwidth 22 kHz 3 4 Inherent distortion Bandwidth 40/80/250 kHz 3 4 Spectrum 10 Hz to 110 kHz automatic to input or generator signal or fixed through entered value any combination of d2 to d9, up to 250 kHz Harmonics <50 kHz ±0.5 dB Harmonics <100 kHz ±0.7 dB Harmonics <250 kHz ±1 dB Fundamental 20 Hz to 10.95 kHz <–110 dB, typ. –115 dB Fundamental 10 Hz to 20 Hz <–100 dB Fundamental 50 Hz to 20 kHz <–100 dB, typ. –105 dB Fundamental 20 kHz to 110 kHz <–90 dB, typ. –95 dB bar chart showing signal and distortion THD+N and SINAD Fundamental Frequency tuning Input voltage Bandwidth Accuracy Inherent distortion analyzer bandwidth 22 kHz 5 Inherent distortion analyzer bandwidth 40/80 kHz 5 Inherent distortion analyzer bandwidth 250 kHz 5 Spectrum 10 Hz to 110 kHz automatic to input or generator signal or fixed through entered value typ. >100 µV with automatic tuning upper and lower frequency limit selectable, one weighting filter in addition Bandwidth < 50 kHz ±0.5 dB (Demo units +0.5/-1.3 dB) <100 kHz ±0.7 dB (Demo units +0.7/-1.5 dB) ≤ 250 kHz ±1 dB (Demo units +1/-1.8 dB) Bandwidth 20 Hz to 22 kHz typ. –110 dB at 1 kHz, 2.5 V <–105 dB +2 µV 6 typ. –108 dB +1.5 µV Bandwidth 20 Hz to 22 kHz <–95 dB + 2.5 µV, typ. –100 dB +1.75 µV 20 Hz to 80 kHz <–88 dB + 5 µV, typ. –95 dB + 3.5 µV Bandwidth 20 Hz to 22 kHz <–95 dB + 2.5 µV, typ. –100 dB +1.75 µV 20 Hz to 110 kHz <–88 dB + 5 µV, typ. –95 dB + 3.5 µV post-FFT Time domain display (WAVEFORM) Standard mode Trace length 512 kS per channel max. Frequency Frequency range Accuracy 20 Hz to 250 kHz ±10 ppm Phase Frequency range Accuracy 20 Hz to 250 kHz 20 Hz to 22 kHz 22 kHz to 50 kHz 50 kHz to 100 kHz 100 kHz to 250 kHz ±0.4 ° ±0.6 ° ±1.0 ° ±1.5 ° 3 Total inherent distortion of analyzer and generator (with option R&S UPV-B1), analyzer with dynamic mode precision. 4 >3.5 V: typ. 3 dB less; <0.5 V: sensitivity reduced by inherent noise. 5 Total inherent distortion of analyzer and generator (with option R&S UPV-B1), analyzer with dynamic mode precision. 6 At full-scale level of measurement range (<–100 dB + 2 µ V with auto range), <–100 dB for input voltage >3.5 V. 4 ® R&S UPV Version 01.00, October 2004 Analog generators 24-bit ∆Σ-D/A converters are used for analog signal generation. The characteristics of the basic generator can be improved and extended with a low-distortion RC oscillator (Low Distortion Generator R&S UPV-B1): – sine with reduced distortion – frequency range up to 200 kHz Outputs XLR connectors, 2 channels, floating/grounded switchable, balanced/unbalanced switchable, short-circuit-proof; max. current <120 mA with external feed Balanced Voltage Crosstalk attenuation Source impedance Load impedance Output balance 0.1 mV to 20 V (rms, sine, open-circuit) frequency <20 kHz typ. 10 Ω , 200 Ω (150 Ω with R&S UPV-U1) >400 Ω (incl. source impedance) at 1 kHz at 20 kHz >115 dB ± 0.5%, 600 Ω ± 0.5% >75 dB >60 dB Unbalanced Voltage Crosstalk attenuation Source impedance Load impedance 0.1 mV to 10 V (rms, sine, open-circuit) frequency <20 kHz 5Ω >200 Ω >115 dB Signals Sine Frequency range Frequency accuracy Level accuracy Frequency response (ref. to 1 kHz) Inherent distortion THD+N Sweep parameters 0.1 Hz to 80 kHz ±10 ppm at 1 kHz 20 Hz to 20 kHz / 70 kHz / 80 kHz Measurement bandwidth 20 Hz to 22 kHz 20 Hz to 80 kHz frequency, level ±0.05 dB ±0.01 dB / ±0.05 dB / ±0.1 dB <–103 dB, typ. –107 dB <–90 dB Sine (with low distortion generator option) Frequency range Frequency accuracy Level accuracy Frequency response (ref. to 1 kHz) Harmonics Inherent distortion (THD) Inherent distortion (THD+N) 7 Sweep parameter 7 10 Hz to 200 kHz 10 Hz to 100 kHz 100 kHz to 200 kHz at 1 kHz 10 Hz to 20 kHz 20 kHz to 100 kHz 100 kHz to 150 kHz 150 kHz to 200 kHz measurement bandwidth 20 Hz to 20 kHz, voltage 1 V to 5 V Fundamental 1 kHz, 1 V to 10 V 20 Hz to 7 kHz 7 kHz to 20 kHz 20 kHz to 50 kHz 50 kHz to 100 kHz Fundamental Meas. Bandwidth 1 kHz, 2.5 V 22 kHz 20 Hz to 20 kHz 22 kHz 20 Hz to 20 kHz 100 kHz ±0.5 % ±0.75 % ±0.05 dB ±0.01 dB ±0.05 dB ±0.15 dB ±0.25 dB typ. <–115 dB (<–120 dB at 1 kHz) <–120 dB typ. <–105 dB <–100 dB <–90 dB <–80 dB –110 dB typ. <–100 dB +2 µV <–88 dB +5 µV frequency, level Total inherent distortion of analyzer and generator, analyzer with dynamic mode precision. Version 01.00, October 2004 ® R&S UPV 5 Stereo sine only with Second Analog Generator, Option R&S UPV-B3 Frequency range Frequency Phase Level Sweep parameters 0.1 Hz to 80 kHz adjustable for each channel -360° to 360° (same frequency in both channels) adjustable for each channel or channel ratio 2/1 frequency and level of channel 1 MOD DIST for measuring the modulation distortion Frequency range Level ratio (LF:UF) Level accuracy Inherent distortion (level ratio LF:UF = 4:1) Lower Frequency Upper Frequency selectable from 10:1 to 1:1 ±0.5 dB at 7 kHz, 60 Hz Sweep parameters upper frequency, level DFD for measuring the difference tone Frequency range difference freqency center frequency ±0.5 dB DFD d2 DFD d3 center frequency, level Level accuracy Inherent distortion 8 Sweep parameters 30 Hz to 2700 Hz 8 x LF to 21.75 kHz –108 dB typ. –103 dB typ. 80 Hz to 2 kHz 200 Hz to 20.75 kHz –120 dB typ. –103 dB typ. DIM (only with Second Analog Generator, Option R&S UPV-B3) for DIM measurements to DIN-IEC 268-3 (dynamic intermodulation distortion) square/sine 3.15/15 kHz or 2.96/14 kHz square/sine amplitude ratio 4:1 bandwidth (3 dB) 30/100 kHz selectable 50 V (25 V unbalanced) Waveform Max. level (VPP) Level accuracy Inherent distortion 9 Sweep parameters ±0.5 dB –105 dB typ. level 2 Sine burst, Sine burst Burst time Interval Low level Bandwidth Sweep parameters 1 sample up to 60 s, 1-sample resolution burst time up to 60 s, 1-sample resolution 0 to burst level, absolute or relative to burst level (0 with sine2 burst) 80 kHz burst frequency, level, time, interval Noise Distribution Gaussian, triangular, rectangular Arbitrary Waveform loaded from file File format Clock rate *.arb memory depth max. 16 k 48/96/192 kHz with bandwidth setting to 22/40/80 kHz Polarity test signal Sinus2 burst with following characteristics: Frequency ON time Interval 8 9 6 1.2 kHz 1 cycle (0.8333 ms) 2 cycles (1.6667 ms) Center frequency >5 kHz, difference frequency <1 kHz; DFD d2–100 dB (typ.) with DC offset. Input voltage >200 mV, typ. values apply from 0.5 to 5 V. ® R&S UPV Version 01.00, October 2004 FM signal Carrier frequency Modulation frequency Modulation 2 Hz to 21.75 kHz 1 mHz to 21.75 kHz 0 % to 100 % AM signal Carrier frequency Modulation frequency Modulation 2 Hz to 21.75 kHz 1 mHz to 21.75 kHz 0 % to 100 % DC voltage Level range Accuracy DC offset 10 Accuracy Residual offset 0 V to ±10 V (±5 V unbalanced), sweep possible ±2 % 0 V to ±10.0 V (±5 V unbalanced) ±2% ±1% of rms value of AC signal Digital Analyzers Frequency limits specified for measurement functions apply to a sampling rate of 48 kHz. For other sampling rates limits are calculated according to the formula: fnew = f48 kHz x sampling rate/48 kHz. Digital Audio Inputs (Option R&S UPV-B2) Balanced input XLR connector, transformer coupling Impedance Level (Vpp) Unbalanced input 110 Ω min. 200 mV, max. 12 V BNC, grounded Impedance Level (Vpp) Optical input 75 Ω min. 100 mV, max. 5 V TOSLINK Channels 1, 2 or both Audio bits 8 to 24 Clock rate 30 kHz to 200 kHz Format professional and consumer format to AES3 or IEC-958 as well as user-defin-able formats at all inputs I2S Input (Option R&S UPV-B41) Input Level 25-contact DSUB connector (male) Channels Low < 0.8 V (-5 V min) High > 2 V (10 V max) 10 kΩ at Vin -0.5 V to 5.5 V 100 Ω at Vin -5 V to -0.5 V and 5 V to 10 V 1, 2 or both multiplexed Word Length 16/24/32 bits per channel Audio bits 8 to 32 Word clock rate 6.75 kHz to 400 kHz Impedance 10 No DC offset for signal generation with Low Dist ON. With DC offset the AC voltage swing will be reduced; specified inherent distortion values apply to DC offset = 0. Version 01.00, October 2004 ® R&S UPV 7 Measurement functions All measurements at 24 bit, full scale RMS value, wideband Measurement bandwidth Accuracy Integration time Filter Spectrum up to 0.5 times the clock rate AUTO FAST AUTO FIX ±0.1dB ±0.01 dB ±0.001 dB AUTO FAST/AUTO 200/4000 samples min., at least 1 cycle GEN TRACK 100 samples min., at least 1 cycle VALUE 0.1 ms to 10 s weighting filters and user-definable filters, up to 3 filters can be combined post-FFT of filtered signal DC voltage Measurement range Accuracy 0 to ±FS ±1% FFT analysis see FFT analyzer section Total harmonic distortion (THD) Fundamental Frequency tuning Weighted harmonics Accuracy Inherent distortion11 10 Hz to 21.90 kHz automatic to input or generator signal or fixed through entered value any combination of d2 to d9, up to 21.90 kHz ±0.3 dB < -155 dB Spectrum bar chart showing signal and distortion THD+N and SINAD Fundamental Frequency tuning Stopband range Bandwidth Accuracy Inherent distortion 11 10 Hz to 21.90 kHz automatic to input or generator signal or fixed through entered value fundamental ±28 Hz, max. up to 2nd harmonic upper and lower frequency limit selectable, one weighting filter in addition ±0.3 dB Bandwidth 20 Hz to 21.90 kHz <–142 dB Spectrum post-FFT of filtered signal Time domain display (WAVEFORM) Standard mode Trace length 512 kS per channel max. Frequency12 Frequency range Accuracy 20 Hz to 20 kHz ±10 ppm Phase12 Frequency range Accuracy 11 20 Hz to 20 kHz ±0.4° Total inherent distortion of analyzer and generator. 12 Only for measurement functions RMS, FFT and THD+N, accuracy applies to 8k FFT with zoom factor 2, Rife-Vincent-2 window; S/N ratio >70 dB. Phase and group delay in high rate mode only with RMS without filter. 8 ® R&S UPV Version 01.00, October 2004 Digital Generators Frequency limits specified for the signals apply to a sampling rate of 48 kHz. For other sampling rates limits are calculated according to the formula: fnew = f48 kHz x sampling rate/48 kHz. Digital Audio Outputs (Option R&S UPV-B2) Balanced output XLR connector, transformer coupling Impedance 110 Ω, short-circuit-proof 0 V to 8 V, in 240 steps Level (Vpp into 110 Ω) Accuracy Unbalanced output Impedance Level (Vpp into 75 Ω) Accuracy ±1 dB (rms) BNC, transformer coupling 75 Ω, short-circuit-proof 0 V to 2 V, in 240 steps Optical output ±1 dB (rms) TOSLINK Channels 1, 2 or both Audio bits 8 to 24 Clock rate 30 kHz to 200 kHz Format internal: generator clock or synchronization to analyzer external: synchronization to word clock input, DARS professional and consumer format to AES3 or IEC-958 as well as user-definable formats at all outputs I2S Output (Option R&S UPV-B41) Output 25-contact DSUB connector (male) Impedance Level Channels 50 Ω, short-circuit-proof LVTTL 1, 2 or both multiplexed Word length 16/24/32 bits per channel Audio bits 8 to 32 Word clock rate Master clock rate word length 16/32 bit word length 24 bit Internal Clock External Wordclock or Masterclock Sync to Internal Clock, External Wordclock word length 16 bit word length 24 bit word length 32 bit Sync to External Masterclock word length 16/32 bit word length 24 bit 432 kHz to 51.2 MHz Clock Input (TX CLK IN) BNC Synchronisation Master/Word clock ratio *) Level Impedance 6.75 kHz to 400 kHz 6.75 kHz to 200 kHz 64, 128, 256, 512 96, 192, 384 128, 256, 512 128, 256, 512 192, 384 < 0.8 V low (min -5 V) > 2 V high (max 10 V) 10 kΩ at Vin -0.5 V to 5.5 V 100 Ω at Vin -5 V to -0.5 V or 5 V to 10 V *) Master clock 51.2 MHz max. Version 01.00, October 2004 ® R&S UPV 9 Signals All signals with 24 bit, full scale General characteristics Dither Frequency accuracy DC offset for sine, stereo sine, DFD and MOD DIST Distribution: Gaussian, triangular, rectangular Level: 0.5 LSB to 1 FS internal clock ±10 ppm relative to clock rate ±1 ppm 0 to ±1 FS adjustable Sine Frequency range Total harmonic distortion (THD) Sweep parameters 2 Hz13 to 21.90 kHz <–155 dB frequency, level Stereo sine Frequency range Frequency Phase Level Sweep parameters 2 Hz13 to 21.9 kHz adjustable for each channel -360° to 360° (same frequency in both channels) adjustable for each channel or channel ratio 2/1 frequency and level of channel 1 MOD DIST for measuring the modulation distortion Frequency range Sweep parameters Lower frequency Upper frequency selectable from 10:1 to 1:1 Level LF:UF 1:1 4:1 10:1 upper frequency, level DFD for measuring the difference tone Frequency range Difference frequency Center frequency DFD d2 DFD d3 Center frequency, level Level ratio (LF:UF) Inherent distortion 11 Inherent distortion 11 Sweep parameters 3013 to 2700 Hz13 8 x LF13 to 21.90 kHz Tbd Tbd Tbd 80 Hz to 2 kHz13 200 Hz13 to 20,90 kHz Tbd Tbd 2 Sine burst, Sine burst Burst time Interval Low level Sweep parameters 1 sample to 60 s, 1 sample resolution burst time up to 60 s, 1-sample resolution 0 to burst level, absolute or referred to burst level (0 for sine2 burst) burst frequency, level time, interval Noise Distribution Gaussian, triangular, rectangular Arbitrary waveform loaded from file File format Clock rate *.arb sampling rate of generator 13 10 memory depth max. 16 k Fixed frequency independent of clock rate. ® R&S UPV Version 01.00, October 2004 Polarity test signal Sine2 burst with following characteristics: Frequency ON time Interval 1.2 kHz13 1 cycle 2 cycles FM signal Carrier frequency Modulation frequency Modulation 2 Hz13 to 21.9 kHz 1 mHz13 to 21.9 kHz 0 % to 100 % AM signal Carrier frequency Modulation frequency Modulation 2 Hz13 to 21.9 kHz 1 mHz13 to 21.9 kHz 0 % to 100 % DC voltage Level range 0 to ±1 FS, can be swept FFT analyzer Frequency range FFT size Digital DC to 0.5 * Sample Rate Analog Bandwidth 22/40/80/250 kHz DC to 22,5/43,5/87/250 kHz Digital 170 dB Analog bandwidth 22/40/80 kHz 120 dB Analog bandwidth 250 kHz 100 (120) dB Digital –170 dB Analog bandwidth 22/40/80 kHz –140 dB Analog bandwidth 250 kHz –120 (-140) dB 512, 1k, 2k, 4k, 8k, 16k, 32k, 64k, 128k, 256k points Window functions Rectangular, Hann, Blackman-Harris, Rife-Vincent 1-3, Hamming, Flat Top Dynamic range Noise floor Filter For all analog and digital analyzers and generators. All filters are digital filters. Analyzer Generator Weighting filters Version 01.00, October 2004 Pre-Filter 1 weighting or user-definable filter Function Filter up to 3 weighting or user-definable filters 1 weighting or user-definable filter – A weighting – CCIR 1k weighted – CCIR 2k weighted – CCIR unweighted – CCITT – C Message – DC noise highpass – Deemphasis J.17, 50/15, 50, 75 – IEC Tuner – Jitter weighted – Rumble weighted, unweighted ® R&S UPV 11 User-definable filters Design parameters Highpass, lowpass filters Bandpass, bandstop filters Notch Third octave and octave filters File-defined filters Analog notch filter Characteristics Frequency range Frequency tuning Stopband Passband 8th order elliptical, type C (for highpass and lowpass filters also 4th order), passband ripple +0/–0.1 dB, stopband attenuation approx. 20 dB to 120 dB selectable in steps of approx. 10 dB (highpass and lowpass filters: stopband attenuation 40 to 120 dB) limit frequencies (–0.1 dB) selectable, stopband indicated passband (–0.1 dB) selectable, stopband indicated center frequency and width (–0.1 dB) selectable, stopband indicated center frequency selectable, bandwidth (–0.1 dB) indicated any 8th order filter cascaded from 4 biquads, defined in the z plane by poles/zeroes or coefficients For measurements on signals with high S/N ratio, this filter improves the dynamic range of the analyzer by up to 30 dB to 140 dB for analyzer bandwidth 22/40/80 kHz, or 120 dB for analyzer bandwidth 250 kHz (typical noise floor of FFT). The filter is also used for measuring THD, THD+N and MOD DIST with dynamic mode precision. available in analog analyzers with measurement functions: – rms, wideband – rms, selective – quasi-peak – FFT analysis 10 Hz to 110 kHz center frequency (fc) – automatic to input signal – coupled to generator – fixed through entered value typ. >30 dB, fc ±0.5% typ. –3 dB at 0.77 x fc and 1.3 x fc, typ. +0/–1 dB outside 0.5 x fc to 2 x fc Sweep Generator sweep Parameters Sweep Stepping frequency, level, with bursts also interval and duration, one- or two-dimensional linear, logarithmic, single, continuous – automatic after end of measurement Sweep speed Two-channel rms measurement 20 Hz to 20 kHz, 30-point generator sweep logarithmic (frequency measurement switched off, Low Dist off). with GEN TRACK AUTO FAST AUTO 0.5 s 1s 2.5 s Display of results Units Level (analog) Level (digital) Distortion Frequency Phase Reference value (level) 12 ® R&S UPV V, dBu, dBV, W, dBm, difference (∆), deviation (∆%) and ratio (without dimension, %, dBr) to reference value FS, %FS, dBFS, LSBs deviation (∆%) or ratio (dBr) to reference value % or dB, referenced to signal amplitude, THD and THD+N in all available level units (absolute or relative to selectable reference value) Hz, difference (∆), deviation (∆%) and ratio (as quotient f/fref, 1/3 octave, octave or decade) to reference value (entered or stored, current generator frequency) °, rad, difference (∆) to reference value (entered or stored) Fixed value (entered or stored). Version 01.00, October 2004 Graphical display of results Monitor Display of results Display functions 8,4“ LCD, colour - numeric display – combi display with numeric value, bargraph, min./max. and limits (for each numeric result) –sweep trace – spectrum - waveform – list of results – bar graph for THD and intermodulation measurements – autoscale – X- and Y-axis zoom – 2 vertical and 2 horizontal cursor lines – search function for max. values – marker for harmonics (spectrum) – change of unit and scale also possible for loaded traces Test reports Functions – screen copy to printer Remote control (option R&S UPV-K4) via IEC 625-2 (IEEE 488) and LAN; commands largely to SCPI Audio monitor Loudspeaker Built in Headphone connector 6.3 mm jack Output voltage (Vp) Source impedance Recommended headphone impedance 7 V max. 100 Ω, short-circuit-proof 600 Ω Modification R&S UPV-U1 Change of source impedance of analog generator to 150 Ω (instead of 200 Ω set as standard) at the factory General data Operating temperature range Storage temperature range Humidity EMC Vibration, sinusoidal Vibration, random Shock Power supply Safety Conformity marks Dimensions (W x H x D) Weight Version 01.00, October 2004 5 °C to +45 °C meets EN 60068 2-1, EN 60068 2-2 –20 °C to +60 °C Max 80% at +45 °C (no condensation) Meets EN 55011/22 5 Hz to 55 Hz, max. 1.8 g at 55 Hz; 55 Hz to 150 Hz, 0.5 g const. Meets EN 60068-2-6, EN 61010-1 10 Hz to 300 Hz, acceleration 1.2 g (rms), meets EN 60068-2-64 40 g shock spectrum, meets EN 60068-2-27, MIL-STD 810 E 100/120/220/230 V ±10%, 50 Hz to 60 Hz, 300 VA Meets EN 61010-1, CAN/CSA-C22.2 No. 1010.1, UL Std. No. 61010B-1 VDE-GS, cCSAus 465 mm x 197 mm x 495 mm 15.0 kg when fully equipped ® R&S UPV 13 Ordering information Order designation Type Order No. Audio Analyzer Accessories supplied R&S UPV 1146.2003.02 Power cable, Quick Start Guide and CDROM (with operating manual) R&S UPV-B1 R&S UPV-B2 R&S UPV-B3 R&S UPV-K4 R&S UPV-B41 R&S UPL-Z1 R&S UPV-U1 1146.5202.02 1146.4306.02 1146.4806.02 1401.9001.02 1146.5402.02 1078.3704.02 1146.1507.02 ZZA-411 1096.3283.00 1146.2084.31 1146.2084.32 1146.2084.39 1157.6870.03 1157.7060.02 Options Low Distortion Generator Digital Audio I/O 192 kHz Second Analog Generator Remote Control I²S Interface XLR/BNC Adapter Set 150 Ohm Modification Recommended extras 19“ Rack Adapter Betriebshandbuch (deutsch) Operating Manual (englisch, UK) Operating Manual (englisch, US) USB Keyboard USB Mouse 14 ® R&S UPV PSL-Z2 PSL-Z10 Version 01.00, October 2004 Product brochure see PD 0758.1306.12 and at www.rohde-schwarz.com (search term: UPV) 16 ® R&S UPV Version 01.00, October 2004 www.rohde-schwarz.com R&S® is a registered trademark of Rohde & Schwarz GmbH & Co. KG · Trade names are trademarks of the owners · Printed in Germany (BI sk) <PD number> · Audio Analyzer R&S® UPV · Version 01.00 · October 2004 · Data without tolerance limits is not binding · Subject to change
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement