accessories - Littelfuse
Accessories
ACCESSORIES
Software............................................................................................. 468
Electrical............................................................................................. 469
Ground Reference Modules, High-Tension Couplers,
& Relay Testers................................................................................... 472
Remote Indication............................................................................... 473
Communication Adapters & Modules................................................ 476
Terminations & Adapters.................................................................... 477
Liquid Level Control............................................................................ 478
Current Transformers (CTs)
CT Selection Guide............................................................................. 479
Current Transformers.......................................................................... 480
Instrumentation & Metering Transformers......................................... 481
Current Transformer Sizing Chart........................................................ 482
Mounting Adapters and Enclosures
Panel-Mount Adapters........................................................................ 483
DIN-Rail & Mounting Adapters.......................................................... 485
Brackets & Clips.................................................................................. 486
Enclosures & Watertight Covers......................................................... 487
Sockets................................................................................................ 488
For More Information…
on Retrofits, Panel Mount Adapters
and more accessories, visit
Littelfuse.com/relayaccessories
©2017 Littelfuse Protection Relays & Controls
467
www.littelfuse.com/relayaccessories
Accessories
Software
SOFTWARE
Protection Relays and Alarm Systems are supplied with
free software. The software simplifies programming and
allows the user to save setpoint files and reuse them for
similar applications.
The software gives the ability to change parameters and
see the impact on the protection time current curves. It
also allows another device curve to be entered to view
simple coordination.
SOFTWARE
Product
Solutions-M
Relay Interface
Software
Features
Provides the ability to configure and monitor Modbus
networks. The features include data logging, real-time data
monitoring and fault and event monitoring. Devices can be
added and configured manually or the software can scan
an existing network to identify devices which can be used
as is or reconfigured by the user. Setpoints for each device
can be uploaded and downloaded for easy monitoring and
reconfiguration.
Accessory For
RS485
TCP/IP networks
MotorSaver and
PumpSaver Devices
Provides remote access to metering, control, data logging, and
programming features. Setpoints can be accessed individually,
downloaded as a file, and protective curves can be plotted.
Metered data can be observed or logged for later study.
FPU-32 MPS FPS
MPU-32 Firmware
Update Utility
Used to update relay firmware to add new features.
FPU-32 MPS EL731
FPS
MPU-32
SE-MON330
Used to receive data from the SE-330. It displays relay set
points and measured values, and features data logging of
information at a selectable interval.
SE-330 SE-330HV
SE-330AU
SE-COMM-RIS
Relay Interface
Software
SE-FLASH
Relay Interface Software
VMPU
Virtual Motor
Protection Relay
VMPS
Virtual Motor
Protection System
VFPU
Virtual Feeder
Protection Relay
MPU-32 Tutorial
MPU-32 Online
Self-Training Tutorial
www.littelfuse.com/relayaccessories
Allows the user to scroll through the MPU-32 Motor Protection
Relay menu.
MPU-32
Allows the user to scroll through the MPS Motor Protection
System menu.
MPS
Allows the user to scroll through the FPU-32 Feeder Protection
Relay menu.
FPU-32
Online Self-Training tutorial for MPU-32 programming.
MPU-32
468
©2017 Littelfuse Protection Relays & Controls
Accessories
Electrical
ELECTRICAL
ELECTRICAL ACCESSORIES
Product
Features
Used in installations with more than one breaker
and more than one Littelfuse Arc-Flash Relay. It
separates the trip paths, so the breakers can be
tripped independently from each other.
PGA-1100.0010
Diode Logic Unit
Full datasheet and ordering information available at
www.littelfuse.com/pga1100
P1004-XX-(X)
Versa-Pot
PART NUMBER
WITH WIRE LEADS
VALUE
P1004-199
50kΩ
P1004-174
100KΩ
P1004-175
200KΩ
P1004-95
P1004-95-X
P1004-17
P1004-16
100kΩ
500kΩ
P1004-16-X
1MΩ
P1004-15
1.5MΩ
P1004-14
2MΩ
P1004-12
P1004-12-X
P1004-13
3MΩ
Panel mountable, industrial potentiometer
recommended for remote time delay adjustment.
The shaft is slotted for screwdriver adjustment and
serrated for slip-proof finger adjustment. Accepts
Versa-Knob or Lock Shaft. May be ordered with
two 8 in. (20.3 cm) wires soldered to pot
(clockwise increase) and female quick connect
terminals on other ends by adding suffix -X to end of
part number.
Specifications
Rating
Taper
Shaft Rotation
Tolerance
0.25W at 55°C
Linear
300° ±5°
±10%
5MΩ
P0700-7
Versa-Knob
P0700-8
Lock Shaft
P1004-9
P1004-10
P1004-31
Mini-Pot
PART NUMBER
VALUE
P1004-9
500kΩ
P1004-10
1MΩ
P1004-31
3MΩ
P0700-21
Mini-Knob
©2017 Littelfuse Protection Relays & Controls
Accessory For
PGR-8800AF0500 AF0100
D0920D1000
P1004-95 & P1004-95-X:
Consult individual datasheet for
compatibility
P1004-174 & P1004-175:
PHS Series
P1004-16 & P1004-16-X:
Series:ERDMERDI ERD3 TRB TRM
TRS TS1TS6
P1004-15, P1004-14, P1004-13, P1004-12,
& P1004-12-X:
Series: ORB ORM ORS TAC1 THD7 TRB TRM TRS TS1 TS2
TS4 TS6 TSD7TSU2000
Versa-Knob is designed for 0.25 in (6.35 mm) shaft
of Versa-Pot. Semi-gloss industrial black finish.
P1004-XX-(X)
Fits 0.25 in. (6.35 mm) potentiometer shafts. Locks
by tightening nut onto four tapered/slotted fingers.
Pressure on the shaft locks control against
mis-adjustment. Nickel plated brass finish.
P1004-XX-(X)
A high quality, industrial potentiometer for remote
time delay adjustment. The shaft extends through
the timer’s center hole for easy panel mounting. Use
mini-mount bracket for standup mounting of timer.
Adjustment by screwdriver or mini-knob. May be
ordered with two 3 in. (7.6 cm) wires soldered to
pot (clockwise increase) and female quick connect
terminals on other ends by adding suffix -X to end of
part number.
Specifications
Rating
Taper
Shaft Rotation
Tolerance
Series: TAC1
TS1
TS2
TS4
TS6
TSD7 TSU2000
0.25W at 55°C
Linear
300° ±5°
±10%
Versa-Knob is designed for 0.25 in (6.35 mm) shaft
of Versa-Pot. Semi-gloss industrial black finish.
469
P1004-XX-(X)
www.littelfuse.com/relayaccessories
Accessories
Electrical
ELECTRICAL
ELECTRICAL ACCESSORIES
Product
Features
P0200-19
Heat Sink Compound
2 grams
P0200-20
Heat Sink Compound
100 grams
P1015-18
Quick Connect
Screw Adaptor
P1015-13
P1015-64
P1015-14
Female Quick
Connect Terminals
Accessory For
Single package/container of heat sink compound
consisting of primarily zinc oxide and having a 12
month shelf life (EOD date on the label). P0200-19
mounts one high current, plated 2 x 2 in. (50.8 x
50.8 mm) timer or flasher. P0200-20 mounts
50+ units.
Any 2 x 2 in. (50.8 x 50.8 mm) plated timer
or flasher.
Screw adaptor terminal designed for use with all
modules with 0.25 in. (6.35 mm) male quick
connect terminals. Screw terminal accepts ring
or spade terminals.
Modules with 0.25 in. (6.35 mm)
male quick connect terminals.
Consult the individual datasheet to
determine compatibility.
These 0.25 in. (6.35 mm) female terminals are
constructed with an insulator barrel to provide
strain relief.
Consult individual datasheet to
determine compatibility.
Dials for use with remote Versa-Pot and panel
mounted Mini-Pot. Reverse screen printed on clear
plastic to avoid damage to printed image.
P1004-9 P1004-10P1004-12
P1004-13P1004-16P1004-31
P1004-95
P0400
Time Adjustment Dials
PART NUMBER
RANGE
INCREMENTS
P0400-12
0.05 - 1s
0.1s
P0400-86
0.1 - 10m
1m
P0400-82
0.1 - 10s
1s
P0400-17
1 - 30s
5s
P0400-83
1 - 60s
10s
P0400-27
0 - 10
MRD*
*Multiplier Reference Dial
VTPXX
The VTP Series mounts on modules with in-line
adjustment terminals. Rated at 0.25W at 55°C.
Available in resistance values from 5K Ω to 5MΩ
VTP
PART NUMBER
RT VALUE
RANGE
PART NUMBER
RT VALUE
RANGE
VTP0E
250kΩ
0.5 - 20s
VTP3L
2MΩ
0.1 - 4m
VTP1B
0.5MΩ
0.05 - 3s
VTP4B
3MΩ
0.05 - 3s
VTP1C
0.5MΩ
0.1 - 10s
VTP4F
3MΩ
0.5 - 60s
VTP1D
0.5MΩ
0.5 - 10s
VTP4J
3MΩ
2 - 180s
VTP2A
1MΩ
0.05 - 1s
VTP4P
3MΩ
1 - 100m
VTP2C
1MΩ
0.1 - 10s
VTP5G
5MΩ
1 - 100s
VTP2E
1MΩ
0.5 - 20s
VTP5K
5MΩ
10 - 1000s
VTP2F
1MΩ
0.5 - 60s
VTP5N
5MΩ
0.1 - 10m
VTP2J
1MΩ
2 - 180s
VTP5P
5MΩ
1 - 100m
VTP2P
1MΩ
1 - 100m
VTPDF
50KΩ
0.5 - 60s
VTP3B
2MΩ
0.05 - 3s
www.littelfuse.com/relayaccessories
470
Series:TAC1 THD7 THDM TS1
TS2 TS4
TS6 TSD7
©2017 Littelfuse Protection Relays & Controls
Accessories
Electrical
ELECTRICAL
ELECTRICAL ACCESSORIES
Product
Features
LPSM003ZXID
Indicating Fuse Holder
LPSM003Z
Accessory For
Littelfuse POWR-SAFE Dead Front holders provide
optimum protection to personnel for Class CC and
Midget-Style fuses. 600 VAC/DC
Series:DLMUHLMUPLM
PLMUPLR PLS
TVM TVWWVM
10 x 38 fast acting, high-interrupting capacity,
current-limiting type fuse. 600 VAC/500 VDC
FH3P
Non-indicating Fuse Holder
0KLK002.T
Midget Fuse (2 Amp)
LPSM003ZXID LPSM003Z
The VRM6048 accessory module allows the voltage
monitor to monitor a 3-phase 550 to 600VAC Line.
VRM6048
Voltage Monitor
Accessory Module
575VAC
VRM Module
→
460VAC
Voltage Monitor
Adjustment
If the measured line voltage is 575VAC, connect as shown and adjust/select the voltage monitor for 460VAC operation.
Package
Molded housing with
encapsulated circuitry
Mounting
Surface mount with one #10
(M5 x 0.8) plastic screw. May
be DIN Rail mounted using P1023-20 Adaptor.
Termination
Screw terminals with captive
wire clamps for up to No.12 AWG wire.
Operating
-40° to 70°C
Storage
-40° to 85°C
Humidity
95% relative, non-condensing
VoltageInput Output*
600VAC
480VAC 575VAC
460VAC 550VAC
440VAC
Series:PLM
PLR
PLS
TVM
TVW
(manufactured after
December 2003)
*The VRM6048 must be connected as shown. If the voltage
monitor is disconnected, the VRM output voltage equals the
input voltage.
The V150LA10AP, a transient voltage surge
suppressor, is a radial leaded varistors (MOVs) that
is designed to be operated continuously across AC
power lines. This UL recognized varistor requires
very little mounting space.
V150LA10AP
LA Varistor
MAX. OPERATING VOLTAGE
PRODUCT
V150LA10AP
AC (V)
DC (V)
150
200
©2017 Littelfuse Protection Relays & Controls
MAX IMPULSE
CURRENT 80.20 μs
CURRENT WAVE
VARISTOR VOLTAGE AT
1MA DC TEST CURRENT
Any of our products that operate below
150 VAC or 200 VDC.
PEAK CLAMPING VOLTAGE
WITH 80.20 μs WAVE
(A)
MIN. (V)
MAX. (V)
VC (V)
1PK (A)
4500
216
264
395
50
471
CAPACITANCE
DISC
DIAMETER
SIZE (MM)
800
14
www.littelfuse.com/relayaccessories
Accessories
Ground Reference Modules, High-Tension Couplers, & Relay Testers
GR MODULES, HIGH-TENSION COUPLERS, & RELAY TESTERS
GROUND-REFERENCE MODULES
Product
SE-GRM024
Ground Reference
Module
SE-GRM048
Ground Reference
Module
SE-GRM125
Ground Reference
Module
SE-GRM250
Ground Reference
Module
SE-GRM500
Ground Reference
Module
SE-GRM780
Ground Reference
Module
SE-GRM1000
Ground Reference
Module
Features
Accessory For
Connects the SE-601 relay to an ungrounded 24 Vdc bus.
SE-601
Connects the SE-601 relay to an ungrounded 48 Vdc bus.
SE-601
Connects the SE-601 relay to an ungrounded 125 Vdc bus.
SE-601
Connects the SE-601 relay to an ungrounded 250 Vdc bus.
SE-601
Connects the SE-601 relay to an ungrounded 500 Vdc bus.
SE-601
Connects the SE-601 relay to an ungrounded 780 Vdc bus.
SE-601
Connects the SE-601 relay to an ungrounded 1000 Vdc bus.
SE-601
HIGH-TENSION COUPLERS
Product
PGH-5000
High Tension Couplers
PGH-6000
High Tension Couplers
Features
Accessory For
Allows 5-kV systems to be connected to relay.
PGR-6100
PGR-3200
Allows 6-kV systems to be connected to relay.
PGR-6100
PGR-3200
PROTECTION RELAY TESTERS
Product
SE-100T
Ground-Fault Relay Tester
SE-400
Ground-Fault-Relay Test Unit
www.littelfuse.com/relayaccessories
Features
Accessory For
Tests the current pickup level ground-fault protection. Tests
the entire ground-fault circuit.
Any Relay on Substations, MCCs,
Central Distribution Panels,
Switchboards, and Test Benches
Tests the current pickup level, time delay and coordination of
ground-fault protection. Tests the entire ground-fault circuit.
Any Relay on Substations, MCCs,
Central Distribution Panels,
Switchboards, and Test Benches
472
©2017 Littelfuse Protection Relays & Controls
Accessories
Remote Indication
INPUT MODULES & METERS
INPUT MODULES
Product
MPS-RTD
Temperature Input Module
MPS-DIF
Differential Current Module
MPU-CIM
Current Input Module
Features
Provides 8 programmable inputs to connect Pt100, Ni100, Ni120,
and Cu10 RTDs.
MPU-32
MPS
Adds motor differential protection, compatible with core balance
and summation current transformer connections.
MPU-32
MPS
Interface between current transformers and MPU-32 or
FPU-32 series relays. Reduces potential for open CT hazard.
MPU-32
FPU-32
Line-of-sight light sensor detects an arc as small as 3 kA within a
2-m half-sphere. Local LED continually displays sensor health or
trip state.
PGA-LS10
Point Sensor
PGA-LS20
Accessory For
PGR-8800AF0500
AF0100
PGR-8800AF0500
Used to detect light and coordinate with current detection to
eliminate nuisance tripping. 8 m (26.2 ft) active; 10 m (32.8 ft) total. AF0100
Fiber-Optic Sensor
PGA-LS30
Used to detect light and coordinate with current detection to
eliminate nuisance tripping. 18 m (59 ft) active; 20 m (66 ft) total
PGR-8800AF0500
AF0100
Light Sensor
Line-of-sight light sensor detects an arc as small as 3 kA within a
2-m halfsphere. Available in both 180˚ and 360˚.
D0920
A0220
Line-of-sight light sensor detects an arc as small as 3 kA within a
2-m half-sphere. Available with 10 or 15 m cable.
Fiber-Optic Sensor
A0200/A0300
Arc Detecting Point Sensor
LCSC10T12
Toroidal Current Sensor
Full datasheet and ordering information available at
www.littelfuse.com/a0220
Remote monitoring of currents up to 50A.
Inner diameter 9.14 mm (0.36”)
PGR-8800
AF0100 D1000
AF0500 D0920
DCSA Series
REMOTE INDICATION & METERS
Product
RK-105
Remote Indication
and Reset Assembly
RK-105I
Remote Indication
Assembly
RK-102
Industrial Remote Indication
and Reset Kit
RK-132
Industrial Remote Indication
and Reset Kit
RK-325
Remote Indication
and Reset Assembly
©2017 Littelfuse Protection Relays & Controls
Features
Accessory For
Panel-mounted remote indication and reset with NEMA 1 rating.
SE-105
SE-107
Panel-mounted remote indication with NEMA 1 rating.
SE-105
SE-107
Panel-mounted remote indication and reset, standard 22 mm
mounting, with NEMA 4 and NEMA 13 rating.
SE-105
SE-107
Panel-mounted remote indication and reset, standard 22 mm
mounting, with NEMA 4 and NEMA 13 rating.
SE-134C
SE-135
SE-145
Panel-mounted remote indication and reset with NEMA 1 rating.
SE-325
473
www.littelfuse.com/relayaccessories
Accessories
Remote Indication
METERS & SENSING RESISTORS
REMOTE INDICATION & METERS
Product
RK-325I
Remote Indication
Assembly
RK-302
Remote Indication
and Reset Kit
RK-332
Remote Indication
and Reset Kit
PGA-0500
Analog % Current Meter
PGA-0510
Features
Panel-mounted remote indication with NEMA 1 rating.
SE-325
Panel-mounted remote indication and reset, standard 22 mm
mounting with NEMA 4 and NEMA 13 rating.
SE-325
Panel-mounted remote indication and reset, standard 22 mm
mounting with NEMA 4 and NEMA 13 rating.
SE-330SE-330AU
SE-330HV
Panel-mounted analog meter displays ground-fault current
as a percentage of the set point.
SE-601
PGR-4300
PGR-6100
Panel-mounted analog ohmmeter displays insulation resistance
from 0 Ω to infinity.
Analog Ohm Meter
Accessory For
PGR-3200
PGR-6101-120
SE-701
SE-703
SE-704
PGR-6100 SENSING RESISTORS
Product
ER-600VC (PGE-600V)
Sensing Resistor
SE-MRE-600
Enclosure
ER-5KV (PGE-05KV)
Sensing Resistor
ER-5WP (PGE-05WV)
Sensing Resistor
ER-15KV (PGE-15KV)
Sensing Resistor
ER-25KV (PGE-25KV)
Sensing Resistor
ER-35KV (PGE-35KV)
Sensing Resistor
ER-72KV (PGE-72KV)
Sensing Resistor
www.littelfuse.com/relayaccessories
Features
Used on systems up to 1 kV. (Continuous duty)
Used in outdoor enclosures. (ER-600VC ordered separately)
Accessory For
SE-330
SE-330AU
SE-325
ER-600VC
Used on systems up to 5 kV. (Continuous duty)
SE-330
SE-330AU
SE-325
Used on systems up to 5 kV, includes weather-protected
terminals for use in outdoor enclosures. (Continuous duty)
SE-330
SE-330AU
SE-325
Used on systems up to 15 kV. (Non-continuous duty)
SE-330
SE-330AU
SE-325
SE-330HV
Used on systems up to 25 kV. (Non-continuous duty)
SE-330
SE-330AU
SE-325
SE-330HV
Used on systems up to 35 kV. (Non-continuous duty)
SE-330
SE-330HV
SE-330AU
Used on systems up to 72 kV. (Non-continuous duty)
474
SE-330HV
©2017 Littelfuse Protection Relays & Controls
Accessories
Remote Indication
REMOTE INDICATION & MONITORING
REMOTE INDICATORS & MONITORS
Product
RM1000
RM1000-3R
RM1000 NEMA 4
Motor-monitoring Device
Features
Motor-monitoring device to be used in conjunction with the
777 family of products (excluding the P1 Series), 77C family of
products, and the 601 voltage monitors, via Modbus protocol
with a communications module. The RM1000/777 motor
management system combines unsurpassed electronic motor
protection and critical, user-friendly, motor monitoring.
Accessory For
777 Series
77C Series
601 Series
Full datasheet available at www.littelfuse.com/rm1000
RM2000
RM2000CBM+
RM2000-RTDW
Motor-monitoring Device
Motor-monitoring device to be used in conjunction with the
777 family of products (excluding the P1 Series), 77C family
of products and the Model 601 voltage monitors, via Modbus
protocol with a communications module. The RM2000/777
motor management system combines unsurpassed electronic
motor protection and critical, user-friendly, motor monitoring.
777 Series
77C Series
601 Series
Full datasheet available at www.littelfuse.com/rm2000
INFORMER
Remote diagnostic tool
Hand-held diagnostic tool designed for use with single-phase
pump relays. The Informer uses an infrared receiver to access
information sent from the relay which can be helpful for
troubleshooting the system. Comes with IR Kit-12 (12" long).
Full datasheet available at www.littelfuse.com/informer
IR Kit-36 (36" long)
Informer Fiber Optic Kit
INFORMER-MS
Remote diagnostic tool
Use with the Informer. Simply attaches to the face of the unit
to provide remote diagnostics without opening the panel.
Hand-held diagnostic tool designed for use with the Littelfuse
455 Series. The Informer-MS uses an infrared receiver to read
valuable information transmitted from the 455, which can be
helpful for troubleshooting the system
111P 111P-ENCL 232-Insider
233P-ENCL 234-P 235P-ENCL
111-Insider-P
231-Insider-P
233P-1.5 233P-1.5-ENCL
235P
LSRX1 111-Insider-P455
LSRX-C231-Insider-P
455 Series
Full datasheet available at www.littelfuse.com/informer-ms
OL-RESET
Remote Reset Module
777-MRSW
Manual Remote Reset Kit
(24” long)
M500
Electronic Megohmmeter
©2017 Littelfuse Protection Relays & Controls
Allows the 777 line of motor and pump relay products to
be manually reset without opening the panel door. Simply
connect the module to the 777 communication port, connect
a wire to each of the two applicable pins on the OL-RESET
and to a normally-open push-button switch (sold separately).
Mount the push-button switch in a convenient location.
777 Series
Allows the 777 line of motor and pump relay products to
be manually reset without opening the panel door. Simply
connect the 9-pin adapter to the 777 communication port and
mount the push-button switch in a convenient location.
777 Series
Automatic, portable, battery-powered insulation tester. This unit is specifically designed as an
inexpensive alternative to costly swing needle megohmmeters. The M500 measures insulation
resistance values of motors, generators and transformers up to 1000 megohms at 500VAC, indicating
the condition of insulation on the zone scale. Its compact design and ease of use makes the M500 a
great diagnostic tool for motor rewind shops, electrical maintenance personnel and pump installers.
475
www.littelfuse.com/relayaccessories
Accessories
Communication
COMMUNICATION ADAPTERS & MODULES
COMMUNICATION ADAPTERS
Product
RS485-RS232
Converter with cable
& plug
RS485-USB
Converter with cable
& plug/RS232:USB
AC700-CUA
Communications Adapter
Features
Accessory For
Allows RS485 devices to be connected to a PC via the
RS232 (serial) port. The converter provides convenient
terminal blocks for making signal and DC power supply
connections. An optional power supply may be required for
laptops or other computers with low power serial ports, or
for very large networks. Pre-wired for easy installation on the
RS485MS-2W module.
RS485MS-2W
Allows RS485 devices to be connected to a PC via the USB
port. The converter provides convenient terminal blocks for
making signal and DC power supply connections. An optional
power supply may be required for laptops or other computers
with low power serial ports, or for very large networks.
Pre-wired for easy installation on the RS485MS-2W module.
RS485MS-2W
Optical network-interface and firmware-upgrade
communication adapter. Field-installed.
EL731
COMMUNICATION MODULES
Product
RS485MS-2W
Communication Module
CIO-DN-P
CIO-120-DN-P
Communication link to PLC/
SCADA/monitoring systems
CIO-EN
Communication link to PLC/
SCADA/monitoring systems
Features
This module is required when the RM1000, RM2000 or other
Modbus capable device is used with 77X-type products.
Full datasheet available at www.littelfuse.com/rs485ms2w
Convenient and cost-effective Devicenet™ interfaces capable
of providing discrete control and monitoring of motor starters,
drives and other devices over a Devicenet™ network.
Accessory For
Series: RM1000 RM2000
77X
777 Series
Full datasheet available at www.littelfuse.com/ciodnp-cio120dnp
The CIO-EN Module (non-POE) is a convenient and costeffective Modbus-TCP and Modbus-RTU interface capable of
providing discrete control and monitoring of an overload relay
over a Modbus network.
777 Series
Full datasheet available at www.littelfuse.com/cioen
CIO-MB
CIO-120-MB
Communication link to PLC/
SCADA/monitoring systems
CIO-777-PR
Communication link to PLC/
SCADA/monitoring systems
Convenient and cost-effective Modbus-RTU interfaces capable
of providing discrete control and monitoring of an overload
relay over a Modbus network.
Full datasheet available at www.littelfuse.com/ciomb-cio120mb
Convenient and cost-effective Profibus interface capable of
providing discrete control and monitoring of motor starters,
drives and other devices over a Profibus network.
777 Series ending in P, -P, or -P2
Full datasheet available at www.littelfuse.com/cio777pr
CIO-601CS-DN-P1
Convenient and cost-effective DeviceNet™ device capable of
providing discrete control and monitoring of motor starters,
drives and other devices over a DeviceNet™ network.
COM 4-20
Send a 4-20mA signal proportional to the output power. It can
also be used to send the input power by setting the efficiency
setting on the 777-AccuPower monitor to one. This module
allows communication to a PLC with an analog input and no
Modbus input.
Communication link to PLC/
SCADA/monitoring systems
777 Series
601-CS-D-P1
777-AccuPower
Full datasheet available at www.littelfuse.com/com420
www.littelfuse.com/relayaccessories
476
©2017 Littelfuse Protection Relays & Controls
Accessories
Terminations & Adapters
TERMINATIONS & ADAPTERS
TERMINATIONS & ADAPTERS
Product
1N5339B
Features
Accessory For
5 W axial-lead ground-check termination. Included with SE-105
and SE-107.
SE-105
SE-107
50 W ground-check termination that is robust and compact for
submersible pumps. Wire lead simplifies installation.
(Replacement for 1N4553B)
SE-105
SE-107
50 W ground-check termination with convenient mounting holes and
screw terminals.
SE-105
SE-107
Temperature compensated 50 W ground-check termination with
convenient mounting holes and screw terminals.
SE-105
SE-107
SE-134C
Temperature compensated 50 W ground-check termination with
convenient mounting holes and screw terminals.
SE-105
SE-107
SE-134C
Temperature compensated 12 W ground-check termination, ideal for
use in cable-coupler end caps and submersible pumps. Mounting
holes and wire leads.
SE-105
SE-107
SE-134C
Temperature compensated 50 W ground-check termination with
convenient mounting holes and screw terminals.
SE-135
SE-145
Temperature compensated 12 W ground-check termination, ideal for
use in cable-coupler end caps and submersible pumps. Mounting
holes and wire leads.
SE-135
SE-145
Termination Assembly
Temperature compensated 50 W ground-check termination with
convenient mounting holes and screw terminals.
SE-135
SE-145
SE-TA12A
SE-TA12B
Used together to allow an SE-134C to monitor a splitter box and
two cables.
SE-134C
Termination Device
SE-TA6-SM
Stud-Mount Termination
Assembly
SE-TA6
Termination Assembly
SE-TA6A
(PGA-0T6A)
Termination Assembly
SE-TA6A-WL
Termination Assembly
SE-TA6ASF-WL
Small-Format Termination
Assembly with Wire Leads
SE-TA12A
Termination Assembly
SE-TA12ASF-WL
Small-Format Termination
Assembly with Wire Leads
SE-TA12A-WL
Termination Assemblies
PPI-600V
Parallel Path Isolator
RK-13
Relay Interface Module
SE-485-DIN
Industrial RS-485 to RS-232
Converter
SE-485-PP
Port-Powered Serial
Converter
CA-945
Serial Connector Adapter Kit
SE-ICUSB232
USB to RS-232 Converter
©2017 Littelfuse Protection Relays & Controls
Parallel ground-path rejection for ground-check monitors. Eliminates
intermachine arcing and prevents stray DC currents from flowing in a
monitored ground wire.
SE-105SE-107
SE-134CSE-135
Separate ground-fault and ground-check indication contacts for the
SE-105, and separate ground-fault and resistor-fault contacts for the
SE-325. Used to provide output to a PLC and operate standard pilot
lights. Complete with conformally coated circuit boards.
SE-105
SE-107
SE-325
MPS
FPS
Industrial network quality RS-485 to RS-233 serial converter.
DIN-rail mounted, 24 Vdc required.
Converts an RS-485 signal to an RS-232 signal. Used for set-point
programming and updating flash memory. 115.2 kbit/s maximum
transfer rate.
Connects an RJ45 to a 9-pin serial connector. Includes 1.5 m cable
and plug-in adapter.
Connects a 9-pin serial cable to a USB port.
477
MPU-32 FPU-32 MPS
FPS
MPU-32
FPU-32
SE-330CA-945
SE-330AUSE-330HV
SE-485-PPSE-485-DIN
www.littelfuse.com/relayaccessories
Accessories
Liquid Level Control
LIQUID LEVEL PROBES & PROBE HOLDERS
LIQUID LEVEL CONTROL ELECTRODES
Product
Features
Threaded stainless steel probe measuring 24 in. (61 cm)
long. Designed for use with PHST-38QTN liquid level
control electrodes.
LLP-24
Liquid Level Probe
Accessory For
PHST-38QTN
PHST-38QTN
Probe Holder
P0700-409
Protective Boot
4.20 (106.68) REF
.75
(19.05)
.80 MAX
(19.05)
.74 MIN
(18.80)
2.25 +.05
(57.15 +1.27)
3/8” NPT
NO.8–32 THDS
Inches (Millimeters)
.68
(17.27)
REF
Designed for use with all conductive liquid level controls.
Composed of insulators and metal parts made of number
300 series stainless steel. These internally conductive probe
holders are designed for a maximum steam pressure of
240 PSI; 400° F maximum. Maximum voltage from electrode
to ground. PHST-38QTN is UL 353 Recognized.
Series:LLC1 LLC2 LLC4
LLC5LLC6 LLC8
PC-XXX-LLC-CZ
PC-XXX-LLC-GM
460-15-100-LLS
Accessories
Current Transformers (CTs)
CT SELECTION GUIDE
RESISTANCE
GROUNDING
GROUNDCONDUCTOR
MONITORING
GROUND-FAULT
PROTECTION
PRODUCT
PHASE CTS
PAGE #
No CTs required
1-20 mA
N/A
–
PGR-3100
No CTs required
Indication only
N/A
–
PGR-3200
No CTs required
Warnings at 30 kΩ & 50 kΩ,
Alarm at 10 kΩ
N/A
–
CT200 Series
10-198 A
EFCT Series
50 mA-4.95 A
SE-CS30 Series
300 mA-29.7 A
SE-704
SE-CS30 Series
10 mA-5 A
N/A
480
EL731
EFCT Series
30-5,000 mA AC and DC
N/A
480
SE-105/SE-107
CT200 Series
0.5-4 A
N/A
480
SE-134C/SE-135
SE-CS10 Series
0.5-12.5 A
N/A
480
CT200 Series
12-200 A
EFCT Series
100 mA-5 A
SE-CS30 Series
600 mA-30 A
CT200 Series
0.5-4 A
CT200 Series
10-200 A
EFCT Series
50 mA-5 A
SE-CS30 Series
300 mA-30 A
480
CT200
10-200 A
480
EFCT Series
(5-A Primary)
50 mA-5 A
SE-CS30 Series
(30-A Primary)
300 mA-30 A
SE-701/SE-703
SE-330
MPU-32*
MOTOR & PUMP
PROTECTION
GROUND-FAULT TRIP LEVEL
(or insulation level)
SE-601
SE-325
MPS*
480
N/A
480
480
480
N/A
480
480
N/A
480
480
N/A
480
1-A, 5-A Secondary CTs
480
480
MPU-32-X69X-PMA16
Existing CTs can be used
or same as MPU-32.
480
MPS-469X-PMA24
Existing CTs can be used
or same as MPS.
480
FEEDER
PROTECTION
FPU-32*
FPS*
ARC-FLASH
PROTECTION
GROUND-FAULT CT
PGR-8800 ‡
CT200 Series
10-200 A
480
EFCT Series
50 mA-5 A
SE-CS30 Series
300 mA-30 A
480
CT200
10-200 A
480
EFCT Series
(5-A Primary)
50 mA-5 A
SE-CS30 Series
(30-A Primary)
300 mA-30 A
N/A
N/A
1-A, 5-A Secondary CTs
1-A, 5-A Secondary CTs
480
480
480
5-A Secondary CTs
(optional)
480
Note: See page 502 for additional information on CT selection. See page 482 for CT sizing chart.
*Phase CTs should be selected with a primary rating of 100-300% of rated current to maintain specified accuracy.
‡Select a CT with a primary rating approximately equal to the system’s rated current.
©2017 Littelfuse Protection Relays & Controls
479
www.littelfuse.com/relayct
Accessories
Current Transformers (CTs)
CURRENT TRANSFORMERS
CURRENT TRANSFORMERS
Product
CT200 (PGC-2056)
Current Transformer
CT200L (PGC-2089)
Current Transformer
EFCT-26 (PGC-3026)
Ground-Fault Current
Transformer
EFCT-1 (PGC-3082)
Ground-Fault Current
Transformer
EFCT-2 (PGC-3140)
Ground-Fault Current
Transformer
EFCT-1FC (PGC-31FC)
Flux Conditioner
SE-CS10-2.5 (PGC-4064)
Current Sensor
SE-CS10-4 (PGC-4108)
Current Sensor
SE-CS10-6 (PGC-4160)
Current Sensor
SE-CS10-8 (PGC-4210)
Current Sensor
SE-CS30-26 (PGC-5025)
Ground-Fault Current Transformer
SE-CS30-70 (PGC-5060)
Ground-Fault Current Transformer
SE-CS30-4 (PGC-5095)
Ground-Fault Current Transformer
SE-CS30-5 (PGC-5130)
Ground-Fault Current Transformer
SE-CS30-8 (PGC-5200)
Ground-Fault Current Transformer
SE-CS40-6
Current Sensor
Features
Inner Diameter
Accessory For
Detects phase current or ground-fault
current (200-A primary)
56 mm
(2.20")
FPS FPU-32 MPS
MPU-32 PGR-8800 SE-105/107
SE-330 SE-325 SE-701
Detects phase current or ground-fault
current (200-A primary)
89 mm
(3.50")
FPS FPU-32 MPS
MPU-32 PGR-8800 SE-105
SE-107 SE-701
Sensitive current transformer used to
detect ground-fault current (5-A primary)
26 mm
(1.02")
EL731
MPS
SE-701
FPS MPU-32
FPU-32
SE-330 Sensitive current transformer used to
detect ground-fault current (5-A primary)
82 mm
(3.23")
EL731
MPS
SE-701
FPS MPU-32
FPU-32
SE-330 Sensitive current transformer used to
detect ground-fault current (5-A primary)
140 mm
(5.50")
EL731
MPS
FPS MPU-32 FPU-32
SE-701
Fits in the EFCT-1 window to reduce
saturation and prevent false operation
due to large surge currents
70 mm
(2.75")
EFCT-1
Detects ground-fault current
64 mm
(2.50")
SE-134C
SE-135
SE-145
Detects ground-fault current
108 mm
(4.25")
SE-134C
SE-135
SE-145
Detects ground-fault current
160 mm
(6.31")
SE-134C
SE-135
SE-145
Detects ground-fault current
210 mm
(8.25")
SE-134C
SE-135
SE-145
Current Transformer for low-level
ground faults, flux conditioner
is standard (30-A primary)
25 mm
(0.98")
FPS FPU-32 MPS
MPU-32 PGR-6100 PGR-6101
SE-330SE-701 SE-704
Current Transformer for low-level
ground faults, flux conditioner
is standard (30-A primary)
60 mm
(2.36")
FPS FPU-32 MPS
MPU-32 PGR-6100 PGR-6101
SE-330SE-701 SE-704
Current Transformer for low-level
ground faults, flux conditioner
is standard (30-A primary)
95 mm
(3.74")
FPS FPU-32 MPS
MPU-32 PGR-6100 PGR-6101
SE-330SE-701 SE-704
Current Transformer for low-level
ground faults, flux conditioner
is standard (30-A primary)
130 mm
(5.12")
FPS FPU-32 MPS
MPU-32 PGR-6100 PGR-6101
SE-330SE-701 SE-704
Current Transformer for low-level
ground faults, flux conditioner
is standard (30-A primary)
200 mm
(7.87")
FPS FPU-32 MPS
MPU-32 PGR-6100 PGR-6101
SE-330SE-701 SE-704
Detects ground-fault current
160 mm
(6.31”)
SE-135 SE-145
NOTE: Contact factory for additional CT offerings.
www.littelfuse.com/relayct
480
©2017 Littelfuse Protection Relays & Controls
Accessories
Current Transformers (CTs)
INSTRUMENTATION & METERING TRANSFORMERS
Description
Littelfuse offers a wide array of instrument rated current
transformers in 1-3 inch diameter opening.
Voltage class: 600V
BIL rating: 10kV
Dimensional Drawing
DONUT STYLE
Donut Style
Foot Mounted
2RL
56RL
76RL
Ordering Information
DONUT MODEL
WINDOW
CURRENT RATIO
CT-0050-D10
1.0"
50:5
CT-0075-D10
1.0"
75:5
CT-0100-D10
1.0"
100:5
CT-0150-D10
1.0"
150:5
CT-0200-D10
1.0"
200:5
CT-0300-D10
1.0"
300:5
CT-0200-D20
2.0"
200:5
CT-0300-D20
2.0"
300:5
CT-0400-D20
2.0"
400:5
CT-0500-D20
2.0"
500:5
FOOTED MODEL
WINDOW
CURRENT RATIO
CT-0050-F10
1.0"
50:5
CT-0100-F10
1.0"
100:5
CT-0150-F10
1.0"
150:5
CT-0200-F10
1.0"
200:5
CT-0300-F10
1.0"
300:5
CT-1200-F15
1.5"
1200:5
CT-0150-F20
2.0"
150:5
CT-0200-F20
2.0"
200:5
CT-0300-F20
2.0"
300:5
CT-0400-F20
2.0"
400:5
CT-0600-F20
2.0"
600:5
Series
CT-0400-F30
3.0"
400:5
Current Ratio
CT-0800-F30
3.0"
800:5
xxx:5 current ratio
FOOT MOUNTED WITH BRASS TERMINALS
2SFT
56SFT
76SFT
Part Numbering System
CT - xxx - D10
Window Size
Style
10 = 1.0 inch
15 = 1.5 inches
20 = 2.0 inches
30 = 3.0 inches
D = Donut Style
F = Footed Style
©2017 Littelfuse Protection Relays & Controls
481
www.littelfuse.com/relayct
Accessories
Current Transformers (CTs)
INSTRUMENTATION & METERING TRANSFORMERS
INSTRUMENTATION AND METERING TRANSFORMERS
Product
Features
Inner Diameter
Littelfuse offers a wide array of
instrument rated current transformers in
1-3 inch diameter opening.
CT-XXXX-DXX
Series
Donut Style Transformer
Full datasheet and ordering information
available at www.littelfuse.com/ctxxxxdxx
Littelfuse offers a wide array of
instrument rated current transformers in
1-3 inch diameter opening.
CT-XXXX-FXX
Series
Footed Style Transformer
Full datasheet and ordering information
available at www.littelfuse.com/ctxxxxfxx
Accessory For
25.4 - 76.2 mm
(1 - 3")
Series:
777
ECSW LSRU
TCSA DCSA ECS
LSR-0
LSR-XX
LSRXTCS
LCSC10T12
25.4 - 76.2 mm
(1 - 3")
Series:
777
ECSW LSRU
TCSA DCSA ECS
LSR-0
LSR-XX
LSRXTCS
LCSC10T12
Current Transformer Sizing Chart
Conductor
Size
(AWG/kcmil)
Installation Instructions:
Minimum CT Window Size (Inner Diameter in mm)
When installing the Zero-Sequence CTs,
ensure the following:
Number of Conductors
1
3
4
6
8
12
12
4
8
9
11
13
15
10
6
10
11
14
16
19
8
7
12
14
17
20
24
6
9
15
18
22
25
31
4
11
19
22
28
32
39
3
13
22
25
31
36
44
2
14
25
28
35
40
49
1
16
28
32
39
45
55
1/0
18
31
36
44
51
62
2/0
20
35
40
49
57
69
3/0
23
39
45
55
64
78
4/0
25
44
51
62
72
88
250
28
48
55
67
78
95
350
33
56
65
80
92
113
500
39
67
78
95
110
135
750
48
82
95
117
135
165
1000
55
95
110
135
156
191
www.littelfuse.com/relayct
482
1. Only the load carrying conductors pass
through the center of the CT. This means
L1 + N for 1-phase and L1+ L2 + L3 for
3-phase.
2. The power conductors pass through
the center of the CT and are preferably
bound together to keep the conductors
uniformly spaced.
3. The power conductors pass perpendicular
to the CT and, where practical, continue
perpendicular to the CT on both sides of
the CT for 3”.
4. The power conductors should not be
installed in a way that allows them to run
along the side edges of the CT.
5. Where practical, locate the CT away
from noise-generating devices such as
transformers, frequency converters, etc.
©2017 Littelfuse Protection Relays & Controls
Accessories
Mounting Adapters and Enclosures
PMA SERIES
Panel Mount Adapters — Retrofits
Example Shown: PMA-3
Description
A variety of protection relay retrofit adapter plates are
available for the products listed below. These adapter plates
simplify the process of updating electromechanical or poorly
functioning existing relays. Consult factory if you have a
specific product to replace that is not featured. Adapters are
available in either plate style for panel mounting or drawout
style depending on the relay being replaced.
Motor, feeder and ground-fault protection upgrades are
available for electromechanical or solid state relays that are
nearing the end of their life.
Features & Benefits
FEATURES
BENEFITS
Mounting
Fits in existing mounting holes and panel openings
Plate style or drawout style adapters are available to
fit various outdated relays
Multiple adapter sizes
Adapter Plates
RELAY TO REPLACE
Example of a panel mount adapter (PMA-3). Relay is for
illustrative purposes only and must be purchased separately
from adapter plate. For more information on our complete
offering of panel mount adapters see the following page.
PANEL MOUNT
NEW RELAY
AB BULLETIN 1406
PMA-14
MPS
FPL-GFRM
PMA-6
SE-701/SE-704
GE S1
PMA-9
MPU-32/FPU-32
GE LODTRAK III
PMA-10
MPU-32
GE MULTILIN 169, 269, or 369
PMA-13
MPS
PMA-16
MPU-32
PMA-16
FPU-32
GE MULTILIN 469
PMA-24
MPS
GE MULTILIN P4A
PMA-15
MPU-32/FPU-32
GEC/MCGG
PMA-3
SE-701/SE-704
GE & WESTINGHOUSE FT-11
PMA-12
MPU-32
P&B GOLDS
Contact Factory
FPU-32
WESTINGHOUSE CO9 & CO11
Contact Factory
FPU-32
For a complete list of the Littelfuse Panel Mount Adapter Plates please see next page.
©2017 Littelfuse Protection Relays & Controls
483
www.littelfuse.com/relayaccessories
Accessories
Mounting Adapters and Enclosures
PANEL-MOUNT ADAPTERS
PANEL MOUNT ADAPTERS
Product
Features
Accessory For
PMA-2
Used when replacing the AB Bulletin 1406.
PMA-3
Adapter Plate
Used when replacing GEC/MCGG ground-fault relays.
Requires PMA-55 or PMA-60.
PMA-4
Used when replacing the Multilin 139/239.
MPU-32
PMA-6
Adapter Plate
Used when replacing FPL-GFRM ground-fault relays.
Requires PMA-55 or PMA-60.
SE-701
PMA-7
Used when replacing the GE Lodtrak II.
MPU-32
PMA-8
Used when replacing an Atkinson Omser II with an SE-130-Series Monitor.
SE-134CSE-135
PMA-9
Adapter Plate
Used when replacing relays in the GE S1 Case.
Requires PMA-55 or PMA-60.
MPU-32FPU-32
PMA-10
Used when replacing the GE Lodtrak III.
MPU-32
PMA-12
Used when replacing GE and Westinghouse FT-11 relays.
MPU-32
PMA-13
Used when replacing the GE Multilin 169, 269, or 369.
MPS
PMA-14
Used for rough cutouts and when replacing the AB Bulletin 1406.
MPS
PMA-15
Used for rough cutouts and when replacing the GE Multilin P4A.
MPU-32FPU-32
PMA-16-RTDB
The PMA-16 mounting plate is used when replacing the GE Multilin 169, 269,
and 369 relays. The PMA-16-RTDB is a mounting bracket for the optional
MPS-RTD Temperature Input Module.
MPU-32FPU-32
PMA-17
Used when replacing Sprecher & Schuh Cet 4.
MPU-32
PMA-18
Used when replacing Sprecher & Schuh Cet 3.
MPU-32
PMA-21
Used when replacing an ABB RACIF.
FPU-32
PMA-23
Custom mounting plate for FPU-32 to replace 3 Westinghouse C0 relays.
FPU-32
PMA-24
Used when replacing the GE Multilin 469.
PMA-55
Used to panel mount the SE-601 and SE-701.
SE-601
PGR-4300
SE-701
SE-704
PMA-60
Used to panel mount the relay; IP 53 and NEMA 3 rating, tamper resistant.
SE-601
PGR-4300
SE-701
SE-704
MPU-32-SMK
Used to surface mount the MPU-32 or FPU-32.
MPU-32FPU-32
Adapter Plate
Adapter Plate
Adapter Plate
Adapter Plate
Adapter Plate
Adapter Plate
Adapter Plate
Adapter Plate
Adapter Plate
PMA-16
Adapter Plate
Mounting Bracket
Adapter Plate
Adapter Plate
Adapter Plate
Adapter Plate
Adapter Plate
Adapter Plate
Adapter Plate
Surface-Mount Kit
MPU-32
SE-704SE-701
MPS
Note: Relays are not included with the PMA-Series Panel Mount Adapters.
www.littelfuse.com/relayaccessories
484
©2017 Littelfuse Protection Relays & Controls
Accessories
Mounting Adapters and Enclosures
DIN-RAIL & MOUNTING ADAPTERS
DIN RAIL & MOUNTING ADAPTERS
Product
Features
Industry standard 35 mm aluminum or steel DIN rail.
C103PM aluminum rail is available in a 36 in.
(91.4 cm) length.
C103PM (Al)
DIN Rail
AC700-SMK
DIN-rail and Surface-mount adapter for back-plane
mounting.
Mount Adapter
D0050
Plastic clip allowing DIN-rail mounting of the
PGR-8800 and AF0500 Arc-Flash Relay.
DIN-Rail Adapter Clip
Allows any 2 x 2 in. (50.8 x 50.8 mm) or 2 x 3 in.
(50.8 x 76.2 mm) module to be mounted on a 35 mm
DIN type rail. Comes complete with mounting
hardware (one #10 - 24 x 1.00 screw and one
#10 - 24 x 1.25 screw) for 0.75 in. (19 mm) and 1 in.
(25.4 mm) thick modules.
P1023-20
DIN Rail Mount Adaptor
Accessory For
Can be used with all DIN-rail
compatible units.
EL731
AF0500
PGR-8800
Consult the individual datasheet to
determine part compatibility.
P0500-178
Surface Mount Adapter
P0500-178 is surface mountable with 2 Quick
Mount Fasteners.
ASXX/DSXX
Series Timers
P0500-179 snaps onto DIN Rail.
ASXX/DSXX
Series Timers
Inches
(Millimeters)
P0500-179
DIN Rail Mount Adapter
Inches
(Millimeters)
©2017 Littelfuse Protection Relays & Controls
485
www.littelfuse.com/relayaccessories
Accessories
Mounting Adapters and Enclosures
BRACKETS & CLIPS
BRACKETS & CLIPS
Product
Features
Accessory For
BZ1
Front Panel Mount Kit
Provides an easy method of through-the-panel
mounting of 8-pin or 11-pin plug-in timers, flashers,
and other controls. May be mounted in panels up to
0.125 in. (3.2 mm) thick. Includes two clamps and
two screws.
1.9 +/-.02
(48.3 +/-.5)
2.6 +/-.02
(66.0 +/-.5)
PANEL
OPENING
Illustrates panel opening size
required to mount BZ1.
Inches (Millimeters)
P1023-6
P1023-7
Mounting Brackets
0.56
(14.3)
0.19
(4.8)
1.5
(38.1)
0.47
(11.9)
d
Series:
ARP FS500 LLC4 LLC5 LLC6
PLMPLMU
PLRPLSPRLM
TDB TDBHTDBL TDI TDIH
TDIL TDM TDMBTDMHTDML
TDR TDS TDSHTDSL TRB
TRDUTRM TRS TRU
1.25
(31.8)
Provides a convenient method of mounting modules.
The 90° orientation of mounting slots makes
installation/removal of modules quick and easy.
Made from steel with a cadmium surface finish.
PART
NUMBER
MOUNTING
HOLE SIZE
MOUNTING METHOD
P1023-6
0.19 in. (4.8 mm)
#8 (M4 x 0.7) screw
P1023-7
0.25 in (6.35 mm) Mini-Pot
Used on many 2" x 2" timers. Refer to
individual series datasheet to determine
if this accessory is compatible.
2.1
(53.3)
Inches (Millimeters)
PSCRB8
Hold-down Brackets
PSC8
PSC11
Hold-down Clips
P1023-2
P Clamp
www.littelfuse.com/relayaccessories
Designed for use with P1011-6 socket. Securely
mounts 8-pin plug-in controls in any position, and
provides protection against vibration. Sold in pairs.
Securely mounts plug in controls in any position.
Also provides protection against vibration. Select the
PSC8 for use with NDS-8, or the PSC11 for use with
NDS-11 sockets. Sold in pairs.
Removable P clamp bracket for mounting MSM
Series timers and FS100 and FS400 Series flashers.
486
P1011-6
NDS-8 Socket
Timers Series:
Flasher Series:
NDS-11 Socket
MSM
FS100
FS400
©2017 Littelfuse Protection Relays & Controls
Accessories
Mounting Adapters and Enclosures
ENCLOSURES & WATERTIGHT COVERS
ENCLOSURES
Product
NGRM-ENC
NGR Monitor Control Panel
Features
NEMA 4 painted steel control panel, complete with the SE-325
or SE-330, and a fused 600/480:120 V PT for relay control power.
Suitable for indoor or outdoor mounting, CSA certified. When
NGR Monitor is back-plane mounted, 22-mm NEMA 4 indicators
and reset button are included. Please contact factory for
additional information.
Accessory For
SE-325
SE-330
www.littelfuse.com/ngrm-enc
NEMA-3R-L A
Enclosure
RM-1000-ENCL
Enclosure
Metal NEMA-3R electrical box with lenses for viewing the
single-phase PumpSaver® status lights. H 6.0” x W 6.0” x D 4.0”
Single-Phase PumpSaver®
Steel enclosure for protecting the RM1000 from weather and
vandalism. Protects from UV, hail, and it seals to keep rain from
contacting the RM1000 connections. The enclosure also features
a built-in padlock tab (padlock not included).
H 6.4” x W 6.3” x D 1.7”
RM1000
WATERTIGHT COVERS
Product
MPU-16A-Y92A-96N
Watertight Cover
SE-IP65CVR-G
Watertight Cover
SE-IP65CVR-M
Watertight Cover
SE-MRE-600
Moisture-Resistant
Enclosure Kit
©2017 Littelfuse Protection Relays & Controls
Features
Watertight cover for outdoor applications.
Watertight cover. Tamper-resistant. IP65 protection.
Watertight cover. Tamper-resistant. IP65 protection.
Protects the connection terminals from snow and rain in
outdoor applications.
487
Accessory For
MPU-32
FPU-32
SE-134CSE-135
SE-330SE-330AU
SE-330HVSE-400
MPS
FPS
ER-600VC
ER-1000HV
www.littelfuse.com/relayaccessories
Accessories
Mounting Adapters and Enclosures
SOCKETS
SOCKETS
Product
OT08PC
Octal Socket 8-Pin
NDS-8
Octal Socket 8-Pin
Screw terminals with
captive wire clamps
P1011-6
Octal Socket 8-Pin
OT11PC
Magnal Socket 11-Pin
SD12-PC
Rectangle Socket 12-pin
NDS-11
11-pin Magnal Socket
Screw terminals with
captive wire clamps
www.littelfuse.com/relayaccessories
Features
Accessory For
8-pin 35mm DIN rail or surface mount octal socket. Rated at
10A @ 600VAC and has pressure clamp terminals.
AWG 12 to 22 (3.2 to 0.33 mm²)
wire sizes. Consult individual
datasheet for compatibility
8-pin 35mm DIN rail or surface mount octal socket. Rated at
10A @ 300VAC. Surface mounted with two #6 (M 3.5 x 0.6)
screws or snaps onto a 35 mm DIN rail. A spring mechanism
allows easy removal. Uses PSC8 hold-down clips.
Up to two #14 AWG
(2.45 mm²) wire size
Series:
ARP FS500LLC4LLC5
PRLM TDB
TDBH TDBL
TDI TDIH TDILTDM
TDMBTDMH TDMLTDR
TDS TDSH TDSLTRDU
TRM TRS
TRU 8-pin surface mount socket with binder head screw terminals.
Rated at 10A @ 600VAC. UL Listed combination when
used with TDM, TDB, TDS Series timers. Uses PSCRB8
hold-down brackets.
Series:
ARP FS500
PRLM TDB
TDR TDS
TRM TRS
Magnal Sockets are for plug-in units
11-pin Plug-in units
Series:
ARP LLC6 TDBTDBH
TDBLTDMBTDS TDSH
TDSL TRB TRDUTRM
TRSTRU
12-pin surface Rectangle Socket.
11 pin 35 mm DIN rail or surface mount socket. Rated at
10A @ 300VAC. Surface mounted with two #6 (M 3.5 x 0.6)
screws or snaps onto a 35 mm DIN rail. A spring mechanism
allows easy removal. Uses PSC11 hold-down clips.
488
LLC4 LLC5
TDM TDMB
TRBTRDU
TRU
ACBC-120
AWG 12 to 22
(3.2 to 0.33 mm²) wire sizes
Series: ARP LLC6 TDBTDBH
TDBLTDMBTDS TDSH
TDSL TRB TRDUTRM
TRSTRU
©2017 Littelfuse Protection Relays & Controls
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF