for Surround - Studio Technologies

for Surround - Studio Technologies
for Surround
Model 74 Central Controller and
Model 75 Control Console
User Guide
Issue 3, November 2016
This User Guide is applicable for systems consisting of:
Model 74: serial number M74-00151 and later;
Model 75: M75-00151 and later
Copyright © 2016 by Studio Technologies, Inc., all rights reserved
www.studio-tech.com
50221-1116, Issue 3
This page intentionally left blank.
for Surround
Table of Contents
Introduction ................................................................... 5
Installation ....................................................................10
Configuration ................................................................16
Operation ......................................................................34
Technical Notes ............................................................39
Specifications ...............................................................44
Appendix A – MIDI Messages ......................................45
Block Diagrams
Model 74 Central Controller
Model 75 Control Console
Model 74/75 User Guide
Studio Technologies, Inc.
Issue 3, November 2016
Page 3
for Surround
This page intentionally left blank.
Issue 3, November 2016
Page 4
Model 74/75 User Guide
Studio Technologies, Inc.
for Surround
Introduction
What This User Guide Covers
This User Guide is designed to assist you
when installing and using the Model 74
Central Controller and the Model 75
Control Console.
StudioComm for Surround
The StudioComm for Surround Model 74
Central Controller and Model 75 Control
Console work together to provide 5.1
surround and stereo source monitoring capabilities, along with a full-featured
headphone “talkback” cue system. The
system is a perfect fit for contemporary facilities that need to perform a variety of audio tasks. These can include surround and
stereo mixing and monitoring, live recording of voice, music, and sound effects, and
on-air broadcast applications. The system’s
features were carefully selected to provide extensive capabilities while remaining
simple to operate. Of overriding concern
is maintaining the quality of the connected
audio sources. This is accomplished using
a combination of excellent circuit design
and carefully selected components. The
Model 74/Model 75 combination is ideal for
adding surround monitoring capability to
disk-based recording systems. It’s also well
suited for upgrading a post-production or
broadcast facility to support multi-channel
monitoring.
A complete StudioComm for Surround
74/75 system begins with the Model 75
Control Console, a compact user control
surface that is intuitive and comfortable
to use. It is designed to reside at the operator’s location. The Model 75 connects
to the Model 74 Central Controller using
Model 74/75 User Guide
Studio Technologies, Inc.
a single 9-pin cable. Occupying one rack
space, the Model 74 provides all audio
input and output circuitry, signal routing
and control, and power supply functions.
To complete the system up to four Model
35 Talent Amplifier modules can be added.
These connect to the Model 74 using
standard 3-pin XLR audio cables. Model
35 units are typically deployed in voiceover booths, studio areas, or other locations where voice or music talent needs
access to a headphone cue feed. Each
unit provides a stereo audio amplifier, user
controls, and support for one or two pairs
of headphones.
Model 74 Central Controller
The Model 74 Central Controller is a
single rack-space (1U) unit that contains
analog, digital, and power supply electronics. Four analog sources can be connected: two surround (5.1) and two stereo. In
many applications the first surround input,
Surround A, will be connected to a multichannel output on an audio console or
digital audio workstation. The second surround input, Surround B, will be connected
to a playback device such as a disk storage system. For film or video post applications Surround A would be considered the
direct source, while Surround B would be
considered the playback source.
The two stereo inputs, Stereo A and
Stereo B, are provided for general-purpose
use and can be connected to a variety
of 2-channel direct and playback sources.
For flexibility, the surround and stereo
inputs are compatible with balanced or
unbalanced signals having a nominal level
range of –12 dBV to +6 dBu. Fifteen-turn
trim potentiometers are used to precisely
calibrate the input signals.
Issue 3, November 2016
Page 5
for Surround
connectors. The Model 74’s audio path
features low-noise, low-distortion analog
switches for input source selection and
laser-trimmed voltage-controlled-amplifier
(VCA) integrated circuits for monitor level
control. One 9-pin D-subminiature connector is used to connect the Model 74 to the
Model 75 Control Console. A second 9-pin
“D-sub” connector is used to interface
remote control signals with the Model 74.
The Model 74’s talent amplifier output uses
a 3-pin male XLR connector. An infrared
receiver module can connect to the Model
74 using a 3.5 mm jack.
The Model 74 provides two 6-channel
monitor outputs. A powerful system feature
is the ability to configure the monitor outputs to meet the exact needs of an installation. In a “straight-ahead” application the
monitor outputs might be configured to
support two independent surround (5.1)
loudspeaker systems. Alternately, one
surround and one stereo monitor system
could be connected. However, other more
unique configurations are also possible.
These include supporting alternate surround monitor speaker systems or adding
additional subwoofer or surround speakers. The monitor outputs are electronically
balanced and designed for connection to
audio power amplifiers or amplified loudspeakers. Protection circuitry provides
power-up and power-down protection of
the connected loudspeaker systems.
An advanced 8-bit microcontroller provides
the logic “horsepower” for the Model 74.
AC mains power is connected directly to
the Model 74, which is factory selected
for 100, 120, or 220/240 V operation.
The internal power supply utilizes two
toroidal mains transformers for quiet
audio operation.
Audio input and output connections are
made using four 25-pin D-subminiature
Figure 1. Model 74 Central Controller Front Panel
Surround
Input A
trim pots
Surround
Input B
trim pots
Stereo
Input A
trim pots
Data
active LED
Stereo
Input B
trim pots
Power
present LED
Figure 2. Model 74 Central Controller Back Panel
AC mains
input connection
To/from
Model 75
Control
Output to
Model 35
Talent
Amplifiers
Remote
control
inputs
Issue 3, November 2016
Page 6
Monitor B output
and line-level
talkback input
Infrared
receiver
input
Surround Input B
and Stereo Input B
connections
Surround Input A
and Stereo Input A
connections
Monitor A output and
line-level cue audio
outputs
Model 74/75 User Guide
Studio Technologies, Inc.
for Surround
Figure 3. Model 75 Control Console Front Panel
Channel mute/solo
Mute/solo
mode select
Talkback
microphone
Stereo to mono
downmix
5.1 to stereo
downmix
Monitor Output
• Speaker system
select
• Reference level
• Mute all
• Dim
• Rotary level control
Input source
select
Talkback
Model 75 Control Console
The Model 75 Control Console is a compact, self-contained unit designed to be
located at the operator’s position. It allows
fingertip control of all monitoring and talkback parameters. Numerous LED indicators provide complete status information. A
major strength of the Model 75 is its ability
to configure, under software control, many
of the operating parameters. All configuration parameters are stored in non-volatile
memory. The Model 75 Control Console
connects to, and is powered by, the Model
74 Central Controller. The Model 75 generates MIDI system-exclusive messages
to control the Model 74. Remote-control
signals connected to the Model 74 Central
Controller are routed to the Model 75 via
pins in the 9-pin interconnecting cable.
The Model 75 provides four buttons and
associated LEDs for selection of the surround and stereo sources to be monitored.
Model 74/75 User Guide
Studio Technologies, Inc.
While in most cases only one input source
will be monitored at a time, multiple inputs
can be selected for simultaneous monitoring. This allows two, three, or all four of
the inputs to be combined (“summed”).
While there is no independent control of
the input levels, this feature can be useful
for creating rough mixes from the source
signals. It is also a fast, effective means of
making a “seat-of-the-pants” check on the
phase relationship between synchronized
signals.
The monitor output levels are controlled
using a large, easy-to-use rotary control.
The “curve” or “taper” of the level control
can be configured to match an operator’s
preference. The choices available are true
logarithmic and modified logarithmic. The
level control auto mute all function allows
the monitor output channels to mute automatically whenever the rotary level control
is in its fully counterclockwise (minimum)
Issue 3, November 2016
Page 7
for Surround
position. This is useful in applications such
as on-air broadcast. By using the reference
level function, the monitor output level can
be set to a pre-configured value. This is
provided for audio-with-picture applications
that require a specific monitor level. The
reference level is easily configured by taking an electronic “snapshot” of the position
of the rotary level control.
One button controls which monitor output,
A or B, is active. For operator convenience,
the dim function allows the monitor output
level to be reduced by a fixed dB amount.
The dim level is configured from four available levels. A mute all function allows
all of the monitor output channels to be
simultaneously muted. The mute/solo section provides individual channel control.
One pushbutton switch sets the operating
mode for either mute or solo. In the mute
mode, individual channels can be muted
as required. In the solo mode, one channel can be monitored while the others are
automatically muted. Depending on the
configuration, multiple channels can be
simultaneously selected for “soloing.” The
flexibility of having both mute and solo
available allows an operator to quickly
select the most comfortable and productive
operating mode.
Two functions allow the format of the
monitored sources to be checked for
level or phase inconsistencies. The 5.1
to stereo downmix function is used to
create a stereo signal from a 5.1 (surround) source. The stereo to mono downmix function allows a stereo signal to be
added (summed) and monitored. The two
downmix functions can be simultaneously
enabled, allowing a surround signal to be
checked for mono compatibility. The operating mode of the stereo to mono downmix
function can be selected from two choices:
Issue 3, November 2016
Page 8
mono-to-left-and-right or mono-to-center.
This allows support for both music and
audio-with-picture applications. A bandpass
filter feature is associated with the stereo to
mono downmix function. It is included to assist an operator in determining compatibility
with “real world” playback environments.
A bandpass filter can be inserted into the
path of the mono signal, allowing
the response of a monaural loudspeaker
associated with an inexpensive television or
portable radio to be simulated.
To support the headphone cue system
functions the Model 75 Control Console
includes three pushbutton switches and
an integral microphone. As expected, one
button is used to enable the talkback function. The other two buttons are used to set
the talkback level over an 8-step range.
These buttons are also used to select
which audio source is routed to the headphones. Two choices are provided: the left
and right channels of the source selected
for monitoring, or the left and right channels
associated with Stereo input B.
In many cases the talkback button contained in the Model 75 will be used to initiate the talkback function. However, some
applications may benefit from being able
to remotely activate talkback. A hard-wired
signal can be connected to the remote
talkback input. In this way various types
of external wired and wireless equipment
can be interfaced. An infrared (IR) receiver
module can also be directly connected.
This allows the use of a wireless transmitter
to enable talkback. The microphone contained within the Model 75 Control Console
provides crisp, clear talkback audio. But
some installations may benefit from using
an alternate source of talkback audio. This
capability is provided by the Model 74’s
line-level talkback audio input.
Model 74/75 User Guide
Studio Technologies, Inc.
for Surround
For flexibility, the system is designed to
easily integrate with recording consoles,
specialized playback systems, and audiofor-picture machine-control electronics.
Four hard-wired remote-control input functions are provided: mute all, dim, talkback,
and input select. By providing access to
the StudioComm’s mute all and dim functions, talkback or slate activity from an
audio console or other communications
system can control the monitor output
level. The remote talkback input allows
an externally provided contact closure or
logic signal to control the talkback function.
This allows easy integration with additional
wired or wireless talkback devices. The
remote input select function is provided
expressly for audio post applications, allowing automatic switching of the StudioComm’s input source whenever the mode
of a recording system changes between
playback and record. This function, referred historically as PEC/direct switching,
allows accurate monitoring during dialog
replacement, Foley, or other overdub
sessions.
In most cases Model 35 Talent Amplifier
modules will serve as the user’s headphone control center. Each Model 35
contains amplifier circuitry, stereo level
control, mono switch, and two output jacks.
For convenience, a microphone mounting
stand adapter is included with each Model
35. In addition to the talent amplifier output, the Model 74 also provides a stereo
line-level cue output. This allows interfacing with other headphone cue systems or
could connect to a transmission system
associated with a remotely located studio
or control room. The line-level cue output
can also serve as a source of “slate” audio
for workstations.
Model 74/75 User Guide
Studio Technologies, Inc.
Level control
Stereo/
mono
switch
Headphone
outputs
Figure 4. Model 35 Talent Amplifier Front Panel
To additional
Model 35
Talent Amplifiers
From Model 74
or another Model 35’s
loop thru connector
Figure 5. Model 35 Talent Amplifier Back Panel
Additional Details
It’s interesting to note that while each
of the two surround inputs has a channel that’s labeled LFE, the corresponding channel on each of the two monitor
outputs is labeled SUB. The term LFE, an
abbreviation for low-frequency enhancement, is used to indicate an audio source.
So LFE is appropriate in reference to the
inputs Surround A and Surround B. But the
term SUB, short for subwoofer, is correct
for the monitor outputs as they are intended to connect to a powered subwoofer or
an amplifier associated with a subwoofer
loudspeaker. In this case the monitor
outputs are feeding subwoofer loudspeakers which are reproducing the LFE content
Issue 3, November 2016
Page 9
for Surround
that arrives via the surround inputs. (It
would be confusing, and technically incorrect, to refer to LFE loudspeakers.)
Installation
In this section you will be installing the
Model 74 Central Controller in an equipment rack. Audio input, monitor output, and
headphone cue system connections will be
made. One or more Model 35 Talent Amplifiers will be connected. A location will be
selected for the Model 75 Control Console
and it will be connected to the Model 74.
If required, external equipment will be
interfaced to the remote control inputs.
AC mains power will be connected to the
Model 74.
System Components
The shipping carton contains one each of
the following: Model 74 Central Controller,
Model 75 Control Console, 9-pin D-sub
interconnecting cable, and user guide.
Units destined for North America also
include an AC mains cord. Your dealer or
distributor will provide an AC mains cord
for non-North American destination. Model
35 Talent Amplifiers will be contained in
separate cartons.
Mounting the Model 74
The Model 74 Central Controller requires
one space (1U) in a standard 19-inch
equipment rack. Select a location that is
convenient to both the analog audio signals and the Model 75 Control Console. A
cable is provided to connect the Model 75
with the Model 74. Secure the Model 74
into the equipment rack using two mounting screws per side.
Issue 3, November 2016
Page 10
Audio Connections
Line-level audio signal connections are
made by way of four 25-pin female D-sub
connectors, located on the Model 74’s back
panel. To implement all the available features four cable harnesses, each with a 25pin D-sub plug (male) on one end and the
desired connectors on the other end, are
necessary. These cable harnesses are not
supplied by Studio Technologies. Note that
our friends in some locations may use the
term “loom” instead of harness.
The wiring scheme used by the D-sub connectors comply with that made familiar by
TASCAM®. Wiring harnesses prepared for
connecting to the Model 74’s surround and
stereo inputs are identical to DA-88-style
input harnesses. A wiring harness prepared
for the monitor output A and line-level cue
outputs is identical to that of a DA-88-style
output harness. A wiring harness prepared
for the fourth D-sub is slightly different. It is
used for connecting with the six channels
of monitor output B as well as the linelevel talkback input. As such, it will require
careful attention when selecting the right
terminations, e.g., six male plugs and one
female connector. Please refer to Figures 6
through 11 for the exact connection details.
Be certain to note that the Model 74’s D-sub
connectors use 4-40 threads.
Unless there’s a special need, it may be
cost and time effective for you to purchase
commercially made cable harnesses. Let
the large market for DA-88-style cabling
help you painlessly install your system!
There is one caveat to using pre-made
harnesses. The sex of the connector associated with the line-level talkback input may
need to be changed. Even so, using premade cables harnesses may still provide
helpful.
Model 74/75 User Guide
Studio Technologies, Inc.
for Surround
Signal
High (+)
Signal
Low (–)
Shield
SURROUND A-L
24
12
25
SURROUND A-R
10
23
11
SURROUND A-C
21
9
22
SURROUND A-LFE
7
20
8
SURROUND A-LS
18
6
19
SURROUND A-RS
4
17
5
STEREO A-L
15
3
16
STEREO A-R
1
14
2
Connections
Notes: 1) Connector type on Model 74 is 25-pin female
D-subminiature (DE-25F). Installer must provide male
(DE-25M). Connector uses 4-40 threaded inserts for
locking with mating plug.
2) Wiring scheme follows TASCAM DA-88 convention.
Standard DA-88-type wiring harnesses are directly
compatible, with the exception of 4-40 screw threads
being required.
Figure 6. Connections for Inputs Surround A
and Stereo A
Signal
High (+)
Signal
Low (–)
Shield
SURROUND B-L
24
12
25
SURROUND B-R
10
23
11
SURROUND B-C
21
9
22
SURROUND B-LFE
7
20
8
SURROUND B-LS
18
6
19
SURROUND B-RS
4
17
5
STEREO B-L
15
3
16
STEREO B-R
1
14
2
Connections
Notes: 1) Connector type on Model 74 is 25-pin female
D-subminiature (DE-25F). Installer must provide male
(DE-25M). Connector uses 4-40 threaded inserts for
locking with mating plug.
2) Wiring scheme follows TASCAM DA-88 convention.
Standard DA-88-type wiring harnesses are directly
compatible, with the exception of 4-40 screw threads
being required.
Figure 7. Connections for Inputs Surround B
and Stereo B
Model 74/75 User Guide
Studio Technologies, Inc.
Surround and Stereo Inputs
The connector labeled Surround Input A
and Stereo Input A, as well as the connector labeled Surround Input B and Stereo
Input B are used to interface with the two
6-channel (5.1 surround) and two 2-channel
(stereo) input circuits. Please refer to Figures 6 and 7 for details on the exact pin out
of the D-sub connectors. Each input circuit
is electronically balanced and intended
for connection to balanced or unbalanced
sources with nominal signal levels of
–12 dBV to +6 dBu. A 15-turn trim potentiometer is associated with each input
channel, allowing the input sensitivity to
be adjusted to match the source’s level.
The configuration section of this guide
provides details on using the trim pots.
Balanced sources should be wired so that
signal high is connected to +, signal low to
–, and shield to the shield connection. With
an unbalanced source, connect signal high
to the + connection, and shield to both the
– and the shield connections. If connecting
to an unbalanced source in this manner results in hum or noise, try connecting signal
high to +, and shield to –; leave the shield
connection unterminated.
It is highly recommended that at least one
of the surround inputs be wired by way of
an audio patch bay. This will allow the channels associated with that input source to
be easily rerouted. While signals generated
within a facility will normally follow a specific
format, such as left, right, center, LFE, left
surround, and right surround, it is possible
that media provided by an outside facility
will follow a different scheme.
Issue 3, November 2016
Page 11
for Surround
Signal
High (+)
Signal
Low (–)
Shield
MONITOR OUT A-L
24
12
25
MONITOR OUT A-R
10
23
11
MONITOR OUT A-C
21
9
22
MONITOR OUT A-SUB
7
20
8
MONITOR OUT A-LS
18
6
19
MONITOR OUT A-RS
4
17
5
CUE OUT-L
15
3
16
CUE OUT-R
1
14
2
Connections
Notes: 1) Connector type on Model 74 is 25-pin female
D-subminiature (DE-25F). Installer must provide male
(DE-25M). Connector uses 4-40 threaded inserts for
locking with mating plug.
2) Wiring scheme follows TASCAM DA-88 convention.
Standard DA-88-type wiring harnesses are directly
compatible, with the exception of 4-40 screw threads
being required.
Figure 8. Connections for Monitor Output A and
Line-Level Cue Outputs
Signal
High (+)
Signal
Low (–)
Shield
MONITOR OUT B-L
24
12
25
MONITOR OUT B-R
10
23
11
MONITOR OUT B-C
21
9
22
MONITOR OUT B-SUB
7
20
8
MONITOR OUT B-LS
18
6
19
MONITOR OUT B-RS
4
17
5
UNUSED
15
3
16
TALKBACK INPUT
1
14
2
Connections
Notes: 1) Connector type on Model 74 is 25-pin female
D-subminiature (DE-25F). Installer must provide male
(DE-25M). Connector uses 4-40 threaded inserts for
locking with mating plug.
2) Wiring scheme follows TASCAM DA-88 convention.
Standard DA-88-type wiring harnesses are directly
compatible, with the exception of 4-40 screw threads
being required.
Figure 9. Connections for Monitor Output B and
Line-Level Talkback Inputs
Issue 3, November 2016
Page 12
Monitor Outputs
Two connectors are used to support the
two 6-channel (5.1 surround) monitor
outputs. Please refer to Figures 8 and 9 for
details on the exact “pin outs” of the D-sub
connectors.
The monitor output channels are intended
for connection to audio amplifiers associated
with monitor loudspeakers, or to the inputs
of loudspeakers that contain integrated amplifiers. The monitor outputs are electronically balanced and capable of driving balanced
or unbalanced loads of 600 ohms or greater.
While balanced operation is preferred, unbalanced operation does not pose a problem.
To connect to an unbalanced load connect
the + terminal as signal high, and both the
– and shield as the signal low/shield. For
optimal unbalanced operation, it is important
to connect both – and shield together directly
on the D-sub plug, not at the other end of the
harness.
Note that while the Model 74’s electronically
balanced output circuits are capable of driving loads of 600 ohms or greater, the output
level will drop slightly as the load impedance
approaches 600 ohms. A 0.5 dB difference
in output level can be expected as the load
impedance changes from 10 k ohms to 600
ohms. This drop is not insignificant and leads
to the recommendation that input loads be
10 ohms or greater.
It’s important to note that the two 6-channel
monitor outputs can be used to create a wide
variety of monitor system implementations.
Configuration choices allow the two outputs
to perform tasks more nuanced than just
serving as a 6-channel A/B switching matrix.
Please carefully review the configuration
section of this user guide prior to connecting
to the monitor outputs; don’t let the system’s
unique flexibility go underutilized!
Model 74/75 User Guide
Studio Technologies, Inc.
for Surround
Headphone Cue System
Two outputs and one input are associated
with the headphone cue system. The talent
amplifier output supplies audio and DC
power for supporting Model 35 Talent
Amplifier units. Using this method a greatsounding, flexible cue system can be
easily created. A stereo line-level output
associated with the headphone cue system is also available. A source of line-level
audio can be connected and can serve as
the talkback audio source. This source can
be used in place of the microphone contained in the Model 75 Control Console.
Talent Amplifier Output
Up to four Model 35 Talent Amplifiers can
be connected to the Model 74’s talent
amplifier output. The output connector is a
3-pin male XLR. For best performance, use
low-capacitance shielded microphone-type
cable to distribute the talent amplifier signal. If there is a choice, select cables with
the heaviest wire gauge commonly available. This will reduce voltage drop when
using long cable runs. Refer to the Technical Notes section for additional information.
The simplest installation would use a
microphone cable to connect the Model 74
to the first talent amplifier; the loop through
connector on that talent amp sending the
signal on to the next talent amp.
For convenience, you may want to wire
your facility to allow easy access to the
talent amplifier signal at all locations where
talent amplifiers might be used. The talent amplifiers connect to the Model 74 in
parallel, so the connectors on the distribution panels or mult boxes should be wired
in parallel.
Model 74/75 User Guide
Studio Technologies, Inc.
Warning: Do not connect the Model
74’s talent amplifier output to anything
but Studio Technologies’ talent amplifiers. Some audio equipment may be
damaged by the DC voltage contained
on pin 2 of the talent amplifier output
connector.
Included with each Model 35 Talent
Amplifier is a nifty mounting adapter that
allows the unit to be conveniently attached
to a microphone stand. Please refer to the
documentation provided in the Model 35’s
shipping carton for details.
Line-Level Cue Output
A 2-channel (stereo) line-level output
provides access to the headphone cue
system signals. The line-level cue output
channel is intended for connection to
an audio amplifier associated with a
headphone cue system. It could also be
useful for connecting with a remotely
located studio or production facility. Using
ISDN or IP-based technology, being able
to send audio signals to literally any part of
the world has become a fairly simple task.
The headphone cue signals are accessible
on one of the 25-pin female D-subminiature connectors, located on the Model 74’s
back panel. Please refer to Figure 8 for
details on the exact “pin out” of the D-sub.
The line-level cue outputs are electronically balanced, capacitor coupled, and
intended to drive balanced or unbalanced
loads of 600 ohms or greater. While balanced operation is preferred, unbalanced
operation does not pose a problem. To
connect to an unbalanced load connect
the + terminal as signal high, and both the
– and shield as the signal low/shield.
Issue 3, November 2016
Page 13
for Surround
Note that while the line-level cue outputs
are electronically balanced, signal is only
driven on the + connection. The – connection serves only as a signal-balancing
return path. This simplified output circuit
was deemed appropriate for headphone
cue system applications. It provides good
audio quality even though its circuitry is not
as sophisticated as that used by the monitor output channels.
Line-Level Talkback Input
An alternate source of talkback audio can
be connected to the Model 74. This audio
source can be used instead of the microphone contained in the Model 75. A configuration parameter selects which source
is active.
The audio source should have a nominal
level of +4 dBu and can be balanced or
unbalanced. Pins on one of the 25-pin
female D-subminiature connectors are used
to connect the signal. Refer to Figure 9 for
details. Balanced sources should be wired
so that signal high is connected to +, signal
low to –, and shield to the shield connection. With an unbalanced source, connect
signal high to the + connection, and shield
to both the – and the shield connections. If
connecting to an unbalanced source in this
manner results in hum or noise, try connecting signal high to +, and shield to –;
leave the shield connection unterminated.
Remote Control Inputs
Support is provided for four hard-wired
remote control input functions: mute all,
dim, talkback, and remote input select.
The inputs are “pulled up” to +5 volts DC
by way of resistors and are active when
brought to the logic low state. Inputs of
this type are commonly referred to as GPI
inputs. While the input circuitry is proIssue 3, November 2016
Page 14
Pin
Signal
1
Shield
2
Spare A (to Model 74)
3
Spare B (to Model 74)
5
Remote Mute All (to Model 75)
6
Remote Dim (to Model 75)
7
Remote Talkback (to Model 75)
8
Remote Input Select (to Model 75)
9
Remote Control Common (to Model 75)
Note:
1) Connector type on Model 74 is 9-pin female
D-subminiature (DE-9F). Installer must provide male
(DE-9M). Connector uses 4-40 threaded inserts for
locking with mating plug.
Figure 10. Connector Pin Out for Remote
Control Inputs
tected from over-current and static (ESD)
discharge, care should be taken to prevent
nasty signals from reaching them. The
inputs are active only when held in the low
state; they can’t be configured to change
state (“latch”) in response to a logic pulse.
A female 9-pin D-subminiature connector,
labeled Remote Control Inputs, is located
on the back panel of the Model 74. It is
used to interface with the four remote
control inputs. Refer to Figure 10 for exact
connection details. Note that pin 1 (shield)
and pin 9 (remote control common) are
electrically identical. In addition to connecting to system common, they connect to the
Model 74’s chassis and mains earth connection. For convenience, the shield of the
interconnecting cable should be connected
to pin 1 (shield), while the return signals of
the remote control sources should connect
to pin 9 (remote control common).
Note that although the remote control connections are physically made to the D-sub
on the Model 74’s back panel, the remote
control input circuitry is actually located in
the Model 75 Control Console. Conductors in the cable linking the Model 74 to the
Model 74/75 User Guide
Studio Technologies, Inc.
for Surround
Pin
Signal
Direction
1
Power Supply Common
74 to/from 75
2
+15 Volts DC
74 to 75
3
Data (MIDI System-Exclusive)
75 to 74
4
Data Common
74 to/from 75
5
Remote Mute All
74 to 75 (Note 2)
6
Remote Dim
74 to 75 (Note 2)
7
Remote Talkback
74 to 75 (Note 2)
8
Remote Input Select
74 to 75 (Note 2)
9
Talkback Mic Audio
75 to 74
Notes: 1) Connector types on Model 74 and Model 75 are
9-pin female D-subminiature (DE-9F). Connectors use
4-40 threaded inserts for locking with mating plug
(DE-9M).
2) Remote control sources connect to D-sub on
Model 74, then passively route to Model 75 via
74/75 interface D-sub.
Figure 11. Connections between Model 74 and
Model 75
Model 75 route the remote control signals
to the actual input circuitry.
Connecting the Model 74 to
the Model 75
A cable with 9-pin D-sub plugs (DE-9M) on
each end is used to interconnect the Model
74 Central Controller with the Model 75
Control Console. A cable, approximately
20-feet (6.1-meters) long, is provided with
each system. The connector labeled To/
From Control Console on the back panel
of the Model 74 is used to connect to the
Model 75.
Should a cable of different length be required, it should be wired in a one-to-one
fashion for all nine pins. Pin 1 serves as
signal common and must be connected
at both ends. A shield connection for the
cable should also be connected to pin 1 on
the Model 74’s end. For best performance
the cable generally should not exceed
50 feet (15.3 meters) in length.
Model 74/75 User Guide
Studio Technologies, Inc.
The reality is that a cable longer in length
than 50 feet should work correctly, as long
as an excellent-quality cable is utilized. We
define “excellent” as extensive shielding
along with very low capacitance. The low
cable capacitance is important as it limits
the amount of data-signal waveform distortion. As far as determining an actual maximum length, just test and see how far away
you can go—if it works, it works! A termination resistor connected from pin 3 to pin 4
at the Model 75’s end of the interconnecting
cable may help to support a longer cable
“run.” The value of the termination resistor
should be in the range of 3.3 k (3300) to
10 k (10000) ohms. A commonly available
¼-watt, 5% tolerance resistor is perfectly
acceptable.
Infrared Remote Control Input
An infrared (IR) receiver module can be
directly connected to the Model 74. This
allows, with an appropriate IR transmitter,
wireless activation of the talkback function. The IR receiver connects to the Model
74 using a 3.5 millimeter 3-conductor jack
which is located on the back panel. The jack
complies with the standard convention for
IR receiver modules: data on the tip lead,
ground on the ring lead, and 12 volts DC
on the sleeve lead. Compatible modules
are available from a number of companies.
As an example, the Xantech® 291-80 looks
nice and works adequately. For excellent
performance under compact florescent lighting conditions the Russound® SaphIR 860
Phantom has proven its worth.
For correct wireless talkback operation
selecting and programming a compatible
transmitter is necessary. Refer to the
Configuration section of this user guide
for details.
Issue 3, November 2016
Page 15
for Surround
AC Mains Power
The Model 74 is internally configured to
operate from an AC mains power source of
nominal 100, 120, or 220/240 volts, 50/60
hertz. Units shipped to North America are
factory selected for 120 volt operation.
Units bound for Japan must be selected for
100 volts, while our friends “down under”
and in Europe receive units set for 220/240
volts. Before connecting the Model 74 to
AC mains power, check that it is configured
to match the local mains voltage. Look on
the back panel (adjacent to the power entry
connector) for the factory-configured voltage. Note that an incorrect configuration
could prevent operation, or cause damage to the unit. Should it be necessary to
change the unit’s operating voltage it must
be performed only at the factory or by a
competent service technician.
The Model 74 uses an IEC-320 C14compatible connector to mate with the
AC mains cord. The wire colors in the AC
mains cord should conform to the internationally recognized CEE color code and
must be wired accordingly:
Connection
Neutral (N)
Line (L)
Protective Earth (E)
Wire Color
Light Blue
Brown
Green/Yellow
Safety Warning: The Model 74 does
not contain an AC mains disconnect
switch. As such, the AC mains cord
plug serves as the disconnection device. Safety considerations require that
the plug and associated outlet be easily accessible to allow rapid disconnection of AC mains power should it prove
necessary.
Issue 3, November 2016
Page 16
As soon as AC mains power is applied, the
Model 74’s power present LED will flash for
a few seconds. After the completion of a
software startup interval the power present
LED will light steadily. The data active LED
on the Model 74 will flash once upon power up, then briefly light upon completion of
the Model 75’s power-up sequence. The
Model 75 will go through its own power-up
sequence, lighting each LED in secession.
Configuration
After the physical installation has been
completed, several configuration issues
must be addressed. On the Model 74 the
surround and stereo inputs must be calibrated using the trim potentiometers. The
operating parameters of the system should
be set using the Model 75 Control Console’s configuration mode.
Level Calibration
Sixteen 15-turn trim potentiometers are
located on the front panel of the Model 74
Central Controller. Taking time to carefully
adjust the trim pots will ensure that accurate monitoring can take place. Each trim
pot allows input signals with a nominal level of –12 dBV to +6 dBu to be utilized. With
care, it’s easy to calibrate the surround and
stereo inputs to within one-quarter of a dB
of the desired value.
The monitor outputs are used as the
measuring point when adjusting the trim
pots. A laboratory-grade audio level meter or equivalent is required for accurate
calibration. In addition, the audio sources
connected to the inputs must be able to
generate continuous audio signals at their
nominal operating level.
Model 74/75 User Guide
Studio Technologies, Inc.
for Surround
Procedure
This procedure will calibrate the surround
and stereo input channels. The trim pots
will be adjusted in groups corresponding
to their associated input sources.
1. Begin by turning the audio amplifiers
or amplified speakers to their off state.
This will protect the loudspeakers and
the operator’s ears from possible
damage.
2. Rotate the level control on the Model
75 to the fully clockwise (maximum)
position.
10. After the calibration procedure has
been completed, rotate the level control on the Model 75 to the fully counterclockwise (minimum) position.
11. After ensuring that the Model 75’s level
control is set to minimum, return AC
mains power to the power amps or
amplified speakers.
Model 75 Operating Parameters
Many StudioComm functions can be configured to meet the exact needs of your
installation. Here’s an overview of what you
can configure:
3. Using the Model 75 Control console,
select Surround A as the input source
and Speaker System A as the selected
monitor output.
• Input channels active
4. On the Model 74, connect the audio
level meter to the left channel of monitor output A.
• Solo
5. Confirm that the audio source’s left
channel is generating a steady signal
at precisely its reference level.
• Speaker systems/monitor outputs
• Talkback
• Power-up mute all
• Level control response
• Level control audio mute all
• Reference level
6. Observing the level meter, adjust
Surround A, trim pot L, to give a precise +4 dBu level at the left channel
output of monitor output A.
• Remote input select
7. Disconnect the level meter from the
left channel of the monitor output.
• Remote dim
8. Repeat steps 4-7 for the right, center,
LFE, left surround, and right surround
channels of Surround A.
• Auto dim off
9. Repeat steps 3-8 for Surround B,
Stereo A, and Stereo B. Obviously, the
stereo inputs have only left and right
channels, requiring only that two trim
pots be adjusted for each.
Model 74/75 User Guide
Studio Technologies, Inc.
• Dim level
• Remote mute all
• Remote talkback
• Talkback dim
• Mono
The Model 75 configuration diagrams,
located at the end of this section, give
details on how each parameter is set. An
overview of each configurable parameter
is provided in the following paragraphs.
Issue 3, November 2016
Page 17
for Surround
Entering and Exiting the Configuration
Mode
A small button is located on the back of the
Model 75 Control Console, adjacent to the
9-pin D-sub connector. Pressing and holding this button for two seconds places the
Model 75 into the configuration mode. In
the configuration mode the Model 75’s array of buttons and LEDs no longer perform
their normal functions, but instead allow
you to observe and change many of the
operating parameters. The mute/solo mode
LEDs light alternately to indicate that the
configuration mode is active.
To leave the configuration mode and return
the Model 75 to normal operation, once
again press and hold the configure button
for two seconds. Note that configuration
changes are stored only after the configuration mode has been exited.
Our apologies to those of you who find the
configure button a pain to use, but it’s supposed to be that way! Seriously, the top of
the button is slightly recessed from the
back panel, making it harder to accidentally activate. We didn’t want normal operation to cease because someone pushed
the Model 75 into a “rats nest” of music
scores or track sheets!
There is no problem frequently “tweaking” the Model 75’s operating parameters
to achieve the desired performance. The
configuration data is stored in non-volatile
memory, which is rated for thousands of
read and write cycles and a retention time
in tens of years.
Input Channels Active
This configuration is a bit tricky to understand, but is really quite simple. The
configuration parameter for the number of
channels active for each input is provided
Issue 3, November 2016
Page 18
for those special cases where a source
has less channels than its usual, e.g., less
than six for Surround A or B.
Let’s look at an example. Surround A is
connected to a 6-channel source, so its
default configuration is fine. But the source
for Surround B is special, having only
three channels: left, center, and right. This
makes it not so “cool” for the operator to
select Surround B for monitoring, as the
unconnected left surround, right surround,
and LFE input channels will get routed to
their respective monitor outputs. Will the
unused input channels pick up significant
noise or hum? Unlikely, but why take a
chance at having a problem. Simply use
the input channels active configuration
function to disable the three unused channels. Now when Surround B is selected,
only the appropriate channels are selected
for monitoring.
Note that when a channel associated with
an input is disabled the input routing circuitry, under software control, no longer
selects it, but the corresponding monitor
output channel does not mute. With our
example, when selecting Surround B, our
mythical L/C/R source, all selected monitor
output channels will remain active, but the
input routing circuitry won’t enable the LS,
RS, and LFE inputs. While to some people
this might seem confusing and possibly a
design fault, it was implemented this way
because the StudioComm system allows
multiple inputs to be simultaneously selected for monitoring; a surround source might
be selected at the same time as a stereo
source. Muting the outputs in response to
a single input channel being selected simply would not do!
Model 74/75 User Guide
Studio Technologies, Inc.
for Surround
A special mode has been included to
disable an input from being accessed
by the operator. This might be useful, for
example, when Stereo B is not connected
to a source, and has no valid reason to
be selected. This might also be useful
when connecting a special source, such
as a house “tie line” or router output, that
shouldn’t normally be accessible. Disabling
an input is simple to perform, just disable
all channels associated with it; six for Surround A and B, two for Stereo A and B. To
confirm that an input has been disabled, all
LEDs associated with that input will flash
on and off. Once the Model 75 is returned
to the normal operating mode the disabled
input cannot be selected.
Speaker Systems/Monitor Outputs
The configuration parameters associated
with the speaker system selection button and monitor output channels offer an
extremely powerful resource. With just a
few button presses a wide range of monitor system implementations can be easily
created. But spending time establishing
the goals, and what steps are needed to
achieve them, can prove very valuable.
Studying the configuration chart may at
first be confusing but should soon cause
comments such as “cool” and “wow, I can
really do that?” to spill out!
Physically, the Model 74 Central Controller
supports the connection of two 6-channel
monitor loudspeaker systems. They are
designated A and B. This means that there
are two output connections for each channel, e.g., two for left, two for right, two for
center, etc. On the Model 75 Control Console a pushbutton allows speaker system
A or speaker system B to be selected.
The configuration parameters allow which
of the twelve physical outputs are active
Model 74/75 User Guide
Studio Technologies, Inc.
when speaker system A is selected, and
which of the twelve physical outputs are
active when speaker system B is selected.
There are no restrictions on what outputs
are active in any situation.
Talkback
Four configurable parameters are related
to the talkback function. The talkback button on the Model 75 can be configured to
operate in either a push-to-talk or latching
(push on/push off) mode.
The talkback function can be set to add
(sum) talkback audio with the selected
cue source. Alternately, it can be configured so that talkback audio will interrupt
and replace the cue source whenever the
talkback function is enabled.
The talkback audio source can be selected
from two choices. In most cases it’s appropriate to use the microphone contained
in the Model 75. For more specialized
applications a source connected to the
line-level talkback input can be effective.
A configuration option enables or disables
the ability to send a source of cue audio
to the talent amplifier and line-level cue
outputs. Typically this option will be set
for enable. In certain situations it may be
desirable to only send talkback audio out
the talent amplifier and line-level talkback
outputs. An example of where this setting
could be appropriate is when one of the
line-level talkback outputs is used, along
with an amplifier and loudspeaker, to create a “stage announce” signal.
Solo
Solo operation can be configured to satisfy operator preference. The additive solo
mode matches the functionality found in
most recording consoles. In this mode,
Issue 3, November 2016
Page 19
for Surround
multiple channels can be simultaneously
“soloed,” allowing those channels to be
monitored at the same time. Other operators may prefer the exclusive solo mode.
When this mode is selected, only one
channel can be selected for solo at a time.
The additive solo mode is the default
setting.
Power-Up Mute All
By default, upon application of AC mains
power the monitor outputs remain muted
after the system’s power-up sequence
has been performed. Then an operator
must manually press the mute all button
to enable the monitor outputs. There may
be cases where having the monitor output
channels return to their respective states
as left at the time of the previous loss of
AC mains power, allowing normal operation automatically to resume.
Level Control Response
As expected, the level control on the Model
75 Control Console is used to adjust the
output level of the monitor output channels.
The amount of rotation required to reach
a specific level can be selected from two
modes. This can be described as allowing
the “curve” or “taper” of the level control to
be configured. The two available modes
are true logarithmic and modified logarithmic. In the true logarithmic mode the level
control provides a precise logarithmic performance over its entire rotation, e.g., the
output level is half of its maximum when
the control is set at its midpoint, i.e., 50%
of its “travel.” In the true log mode, normal
listening may require the level control to
be set to approximately the “2-o’clock”
position.
Other users may be more comfortable
with the response given by the modified
Issue 3, November 2016
Page 20
logarithmic mode. This provides a much
greater output level during the first 50% of
the level control’s travel. When configured
for the modified log mode, normal listening
may require the level control to be set to
the 11- or 12-o’clock position. The modified log mode more closely matches the
monitor level control performance found in
many audio consoles. As such it is selected as the default mode.
It’s important to note that changing the
level control response mode will impact the
reference level. Changing from modified
log to true log, or vice-versa, will change
the reference level. Technically, the mathematical value stored as the reference
level does not change, but the loudness
that is heard by the operator will change.
Be warned! Changing the level control
response may require the reference level
to be recalibrated.
Level Control Auto Mute All
The level control auto mute all function
automatically mutes the monitor output
channels whenever the rotary level control
is in its fully counterclockwise position. In
some applications it may be desirable to
disable this function. When disabled the
rotary level control adjusts the monitor
output level over the approximately 72 dB
range; no automatic muting takes place.
Reference Level
For audio-with-picture applications it’s
critical that mixing be done in reference
to a known monitor loudspeaker level. This
is often referred to as mixing to “85 dB” on
the monitors. The Model 75 Control Console allows a precise monitor output level
setting to be stored, and then enabled by
pressing the button labeled Ref Level.
Model 74/75 User Guide
Studio Technologies, Inc.
for Surround
Setting the reference level is very simple:
1. Set up a precision sound pressure
level (SPL) measuring device at the
desired listening location.
2. Place the StudioComm system in the
normal operating mode, not the configuration mode. Be certain that the
reference and dim functions are not
active.
3. Use the Model 75 Control Console to
select the input source that contains
the desired reference signal source,
e.g., pink noise.
4. Select the desired monitor output,
speaker system A or B.
5. Observing the SPL meter, adjust the
Model 75’s rotary level control until
the desired reference output level has
been reached.
6. Being careful not to touch the position
of the rotary level control, enter the
configuration mode by pressing and
holding the configuration button located on the Model 75’s back panel.
7. Once the configuration mode has been
entered, the monitor outputs will mute.
Press and hold the reference button
until its associated LED lights. This will
take approximately five seconds. The
LED will light to indicate that a “snapshot” of the new reference level has
been taken.
8. To store the new reference level in
memory, exit the configuration mode by
again pressing and holding the configure button.
This level is now permanently stored as
the reference level. Only by repeating the
procedure can the value be changed.
Model 74/75 User Guide
Studio Technologies, Inc.
Once the configuration mode has been
exited, the monitor output channels will
again become active. Confirm that the correct level has been stored by pressing the
reference button. The SPL meter should
again display the desired level. If not,
repeat the calibration procedure.
You might wonder why you have to press
and hold the reference button for five seconds before the selected value is stored.
This is provided specifically so that some
careless person won’t accidentally change
the reference level while they are “playing
around” in the configuration mode! Only if
you know the “secret” will you be able to
store a new value.
Remote Input Select
The remote input select function requires
configuring two parameters: mode and
input to be selected. The mode can be
selected from three choices: disabled,
exclusive, and non-exclusive. As expected,
when configured for disabled, the function
cannot be activated. When configured for
exclusive, whenever the function is activated only the specified input will be active.
When configured for non-exclusive, whenever the function is activated the specified
input will be added (summed) with any
other input or inputs that are already active. The input can be selected from among
the two surround and two stereo input
sources.
Dim Level
The dim function is used to reduce the
monitor output level by a preset amount.
The reduction is in dB relative to the monitor output’s current level. There are four
dim level values available: 10, 15, 20,
and 25 dB.
Issue 3, November 2016
Page 21
for Surround
Remote Mute All
Two configuration choices are associated
with the remote mute all function: disabled
and enabled. To utilize the function simply
configure it for enabled.
Remote Dim
Two configuration choices are associated
with the remote dim function: disabled and
enabled. To utilize the function simply configure it for enabled.
Remote Talkback
Two configuration choices are associated
with the remote talkback function: disabled and enabled. To utilize the function
simply configure it for enabled. Note that
this setting applies to both the hard-wired
remote talkback input and the infrared (IR)
receiver talkback input. The function must
be enabled for either of these inputs to be
active.
Auto Dim Off
The auto dim off function is unique, making the dim function respond to real-world
operating conditions. When enabled, the
function automatically turns the dim function off if a change is made to the control
room level potentiometer while the unit
is already in dim mode. This prevents a
heart-stopping blast of audio when an
engineer presses the dim button to turn
dim on, but actually turns it off because the
unit was already in the dim mode. While it’s
hard to explain unless you’ve used a console and experienced this in person, trust
us, this situation does happen! Auto dim
off is a wonderful “real-world” function and
in most cases should be enabled.
Talkback Dim
The talkback dim mode selects whether
the dim function is enabled whenever the
Issue 3, November 2016
Page 22
talkback function is active. In most applications it’s desirable to have the monitor
loudspeakers dim whenever talkback is
active. This ensures that headphone cue
system users will clearly hear voice cue
signals, rather than being overwhelmed
with audio signals coming from the loudspeaker system. However, there may be
special applications where it’s not desirable for dim to enable when talkback is
active. This could include the case where
the monitor system is normally set by a
user to operate at a very low SPL level.
Stereo to Mono Downmix Modes
The stereo to mono downmix operating
mode can be selected from two choices:
mono-to-left-and-right or mono-to-center.
For music mixing it’s common to have a
mono function combine (sum) the signals
from the left and right, or 5.1 downmixed to
left and right, channels and route the result
to both the left and right output channels.
For broadcast and cinema use, it may be
more appropriate to combine the left and
right signals and route the result to the
monitor system’s center channel. By
default the mode is set to the mono-tocenter mode.
Mono Attenuation
To meet the needs of the operator and
specific program content, an attenuation
level when mono-to-center is active can
be configured. The choices are 0, 3, 4, and
6 dB. Selecting 0 dB is equivalent to the
attenuation function being disabled. This
results in no attenuation occurring when
stereo to mono downmix is active. This
is provided for those special cases when
the stereo to mono downmix mode is set
to mono-to-center and no phase coherent signals are expected to be part of the
left and right, or 5.1 downmixed to left and
Model 74/75 User Guide
Studio Technologies, Inc.
for Surround
right, channels. While the 0 dB setting is
not generally appropriate for music mixing,
it may find use in broadcast and cinema
applications. The 3 dB and 4 dB settings
are good choices for the mono-to-center
mode when monitoring mixes that have
significant phase coherence, such as
music sources. The 6 dB setting is provided for compatibility with the mono function
found on many audio consoles. As the
factory default, the 3 dB attenuation value
was selected.
Auto 5.1 to Stereo Downmix
The 5.1 to stereo downmix function can
be configured to automatically enable
whenever the stereo to mono downmix
function is enabled. This is provided to
ensure accurate monitoring of 5.1 sources
when stereo to mono downmix is enabled.
This is the default mode, although it can
be changed as desired.
Restore Factory Defaults
The restore factory defaults function is provided primarily for factory use. In this way
a system can be shipped with the default
settings selected. While you are welcome
to use this function, be careful so that your
configuration efforts aren’t wasted. Specifically, be aware that the reference level
is reset to minimum level. All the other
parameters are fairly easy to set up, but
resetting the reference level would require
getting out an SPL meter and a calibrated
signal source. This is a hassle you may not
need!
Model 74/75 User Guide
Studio Technologies, Inc.
Infrared Transmitter
Configuration
To support the infrared (IR) remote
talkback function an IR transmitter
module must be obtained and configured.
As of the writing of this user guide Studio
Technologies’ does not offer such a device.
The Model 75’s software was designed to
support the use of many 3rd-party “universal” remote controls. Units from retailer RadioShack®, priced as low as US$10, have
been used successfully. For a talkback
command to be recognized the remote
control should be programmed to emulate
an RCA DVD player’s play command. (It’s
also possible that a setting for the Microsoft® Xbox® will also work!) The universal
remote may offer several choices for this
sequence. A little experimentation may be
required so that a compatible emulation is
selected. The Model 74 requires a baud
rate of 650.
Issue 3, November 2016
Page 23
for Surround
Model 75 Configuration—Entering and Exiting
Configuration Mode
and hold the configuration
 Press
button for two seconds to enter or
exit the configuration mode.
These LEDs will light alternately
when configuration mode is active.
Issue 3, November 2016
Page 24
Model 74/75 User Guide
Studio Technologies, Inc.
for Surround
Model 75 Configuration—Input Channels Active
and hold an input
 Press
button (one at a time) to
display and select which
channels associated with
that input are active.
When an input button is pressed, these
LEDs display which input channels are
active for that input. A lit LED indicates
that the channel is active. Use the buttons
to change the configuration.
Default:
For Surround A and Surround B, all six channels (L, C, R, LS, RS, LFE) are active.
For Stereo A and Stereo B, both channels (L, R) are active.
Note:
A special input disable function is available. By disabling all channels associated with a specific input, that
input will no longer be available during normal operation. While in the configuration mode, all LEDs associated
with an input will flash to indicate that the input has been disabled. This function is useful if an input is not going
to have a source associated with it. Then during normal operation this input cannot be selected, minimizing
any confusion caused by selecting an invalid input source.
Model 74/75 User Guide
Studio Technologies, Inc.
Issue 3, November 2016
Page 25
for Surround
Model 75 Configuration—Speaker Systems/Monitor Outputs
When an output button is pressed, these LEDs display which
output(s) are assigned to speaker systems A and B:
Press Surround A button to assign output A to speaker system A;
Press Surround B button to assign output B to speaker system A;
Press Stereo A button to assign output A to speaker system B;
Press Stereo B button to assign output B to speaker system B.
and hold an output button (one
 Press
at a time) to display and select which
A lit LED indicates that the output is assigned to that speaker system.
output channels are assigned to
speaker systems A and B. The LFE
button is used for the sub outputs.
Speaker
System A
Speaker
System B
Output B Output A
Default:
For Speaker System A all six channels are assigned to output A only.
For Speaker System B all six channels are assigned to output B only.
Note:
A special output disable function is available. By disabling all outputs associated with either speaker system A
or B, that system will no longer be available during normal operation. This function is useful if only one output
is going to be utilized. Then during normal operation this output cannot be selected, minimizing any confusion
caused by selecting an invalid speaker system.
Issue 3, November 2016
Page 26
Model 74/75 User Guide
Studio Technologies, Inc.
for Surround
Model 75 Configuration—Talkback
While holding the
Talkback button, these
LEDs display the
status of the talkback
audio source. Press
the Surround A button
to select Model 75 mic
as talkback source.
Press Surround B to
select Aux TB In as
talkback source.
Surround A LED lit
indicates Model 75 mic
as talkback source.
Surround B LED lit
indicates Aux TB In as
talkback source.
While holding
the Talkback
button, press
the Ref Level
button to enable or disable
cue audio program source;
LED on means
cue audio program source
enabled.

Default:
Press and hold the
Talkback button to
display and configure
talkback functions.
While holding the Talkback button,
press the Dim button to toggle
between latching or momentary
operation; LED on means the
button is set to latch.
While holding the Talkback button,
press the Mute All button to toggle
between talkback adds to or talkback interrupts cue audio; LED
on means talkback interrupts.
Talkback button is set for momentary operation.
Talkback adds to cue audio mode enabled.
Talkback audio source is Model 75 mic.
Cue program audio enabled.
Model 74/75 User Guide
Studio Technologies, Inc.
Issue 3, November 2016
Page 27
for Surround
Model 75 Configuration—Solo, Power-Up Mute All, Level
Control Response, and Level Control Auto Mute All
When the Speaker System A/B button
is pressed, these LEDs display the
status of the solo mode. When LED L
is lit additive solo mode is enabled;
when LED C is lit exclusive solo mode
is enabled. Use the buttons to change
the configuration.
When the Speaker System A/B button is
pressed, these LEDs display the status of
the power-up mute all function. When LED R
is lit the state of mute all is saved at power
down and followed upon power up; when
LED LS is lit the system is always in mute all
upon power up. Use the buttons to change
the configuration.
When the Speaker System A/B button is
pressed, these LEDs display the status
of the level control response mode. When
LED RS is lit the level control provides a
true logarithmic response. When LED LFE
is lit the level control provides a modified
logarithmic response. Use the buttons to
change the configuration.

Press and hold
the Speaker
System A/B button
to display and
select the status
of the solo mode,
power-up mute
all function, level
control response
mode, and level
control auto mute
all function.
Press and hold the Speaker System A/B
button to display and select the status of
the level control auto mute all function. When
the LED is lit the function is enabled. Use the
button to change the configuration.
Default:
Additive solo mode enabled.
Upon power up, mute all function enabled.
Level control provides modified logarithmic response.
Level control auto mute all function enabled.
Issue 3, November 2016
Page 28
Model 74/75 User Guide
Studio Technologies, Inc.
for Surround
Model 75 Configuration—Reference Level
and hold the Ref button for five
 Press
seconds to take a “snapshot” of the level
control’s present setting. The Ref LED will
light when the “snapshot” has been taken.
Default:
Fully attenuated (minimum) monitor output level.
Note:
The 5-second delay is a safety feature, ensuring that the reference level will not be accidently changed.
To permanently store the new value, you must still exit the configuration mode.
Model 74/75 User Guide
Studio Technologies, Inc.
Issue 3, November 2016
Page 29
for Surround
Model 75 Configuration—Remote Input Select
These LEDs display the mode of the remote input select function.
LED L lit means that the function is disabled. LED C lit means that
the function provides exclusive input select. LED R lit means that
the function provides non-exclusive input select. Use the buttons
to change the configuration.
When the Mute All button is pressed, these LEDs display
the input associated with the remote input select function:
and hold the Mute All button
 Press
to display and configure the remote
LED Surround A lit means Surround A;
LED Surround B lit means Surround B;
LED Stereo A lit means Stereo A;
LED Stereo B lit means Stereo B.
input select function.
Use the buttons to select the input.
Default:
Remote input select function disabled.
Surround A associated with remote input select function.
Issue 3, November 2016
Page 30
Model 74/75 User Guide
Studio Technologies, Inc.
for Surround
Model 75 Configuration—Dim Level, Remote Mute All, Remote
Dim, Remote Talkback, Auto Dim Off, and Talkback Dim
These LEDs display the configuration
of remote mute all. LED L lit means that
remote mute all is disabled; LED C lit
means enabled. Use the buttons to
change the configuration.
These LEDs display the configuration
of remote dim. LED R lit means that
remote dim is disabled; LED LS lit
means enabled. Use the buttons to
change the configuration.
These LEDs display
the status of the remote talkback inputs
(hard-wired and IR).
LED RS lit means
that the inputs are
disabled; LED LFE
lit means the inputs
are enabled. Use the
buttons to change
the configuration.
Press Mute All to
toggle the automatic
dim off function; LED
on means auto dim
off function is active.
When the Dim button is pressed, these
LEDs display the selected dim level:
LED Surround A lit means 25 dB dim;
LED Surround B lit means 20 dB dim;
LED Stereo A lit means 15 dB dim;
LED Stereo B lit means 10 dB dim.
Use the buttons to select the dim level.
Default:
and hold the Dim button to display
 Press
and select the dim level, remote mute all,
remote dim, talkback remote input, and
auto and talkback dim off configurations.
Press the Talkback button to toggle the
talkback dim function; LED on means
talkback dim function is active.
20 dB dim level.
Remote mute all disabled.
Remote dim disabled.
Remote talkback inputs (hard-wired and IR) disabled.
Auto dim off enabled.
Talkback dim enabled.
Model 74/75 User Guide
Studio Technologies, Inc.
Issue 3, November 2016
Page 31
for Surround
Model 75 Configuration—Stereo to Mono Downmix

Press and hold the Mono button to display
and configure the stereo to mono downmix
mode, whether 5.1 to stereo downmix is
automatically activated when stereo to mono
downmix is activated, and the attenuation
level when mono is active.
When the Mono button is pressed, these LEDs display the
mode of the stereo to mono downmix function. When LED L
is lit the mono-to-left-and-right mode is selected. When LED C
is lit the mono-to-center mode is selected. Use the buttons to
change the configuration.
When the
Mono button is
pressed, this
LED displays
whether 5.1 to
stereo downmix
is automatically
activated when
the stereo to
mono downmix function
is active. LED
lit means that
5.1 to stereo
downmix will
automatically
activate. Use
the button to
change the
configuration.
When the Mono button is pressed, these LEDs display
the attenuation level when mono-to-center is active:
LED Surround A lit means 6 dB;
LED Surround B lit means 4 dB;
LED Stereo A lit means 3 dB;
LED Stereo B lit means 0 dB.
Use the buttons to select the attenuation level.
Default:
Stereo to mono downmix mode: mono-to-center.
3 dB attenuation when mono-to-center is active.
5.1 to stereo downmix automatically activated when stereo to mono downmix activated.
Issue 3, November 2016
Page 32
Model 74/75 User Guide
Studio Technologies, Inc.
for Surround
Model 75 Configuration—Restore Factory Defaults
and hold both Surround A and Stereo B buttons for five seconds to restore Model
 Press
75 factory defaults. Once defaults have been restored, the LEDs will light. After buttons
are released, configuration mode will be exited and normal operation will resume.
Factory Defaults: All channels associated with each input are active.
Speaker system A all six channels are assigned to output A only.
Speaker system B all six channels are assigned to output B only.
Talkback button is set for momentary operation.
Talkback adds to cue audio mode enabled.
Talkback audio source is Model 75 mic.
Cue program audio enabled.
Additive solo mode enabled.
Upon power up, mute all function enabled.
Level control operates modified logarithmic.
Level control auto mute all function enabled.
Reference level is set for fully attenuated (minimum) monitor output level.
Remote input select function disabled.
Surround A associated with remote input select function.
20 dB dim level.
Remote mute all disabled.
Remote dim disabled.
Remote talkback inputs (hard-wired and IR) disabled.
Auto dim off enabled.
Talkback dim enabled.
Stereo to mono downmix mode: mono-to-center.
3 dB attenuation when mono-to-center is active.
5.1 to stereo downmix automatically activated when stereo to mono downmix activated.
Note:
The 5-second delay is a safety feature, ensuring that the factory defaults will not be accidently restored.
Model 74/75 User Guide
Studio Technologies, Inc.
Issue 3, November 2016
Page 33
for Surround
Operation
Now that you’ve installed and configured
the system, you’re ready to go. You should
find operation very easy.
Model 74 Central Controller
The Model 74’s front panel contains
two LEDs. The power LED should be lit
whenever AC mains power is connected.
The data LED will light whenever a MIDI
system-exclusive message is received
from the Model 75.
Model 75 Control Console
StudioComm operation is controlled using
the Model 75 Control Console and, if connected, the remote control inputs. To make
things easy to describe, we’ve divided
the StudioComm functions into six main
groups: input source selection, downmix,
monitor output functions, mute/solo, headphone cue system/talkback, and remote
controls.
Input Source Selection
Input source selection is simple. To select
an input source for routing to the monitor outputs, press one of the four input
source buttons. The corresponding LED
will light to let you know that the input has
been selected. You can select more than
one input source simultaneously; up to all
four. The selected inputs will be summed
(combined). Start by pressing and holding
the button associated with the first desired input source. While the button is still
pressed, add the extra inputs by momentarily pressing the buttons associated with
them. The LEDs will light to tell you which
inputs have been selected.
Issue 3, November 2016
Page 34
A recall feature is an integral part of the
input selection process. It’s a bit confusing
to explain, but simple once you experience
it in “real time.” A one-sentence explanation would describe the input recall feature
as allowing the system to return to the
previously selected input (or inputs) by
simply pressing one button. It was included
specifically for film-post applications where
it’s important to be able to change quickly
between a combination of inputs, such as
two “stems,” and a single input.
Let’s begin the explanation with an example: A film-post facility where the usual
monitoring setup has both Surround A and
Surround B simultaneously selected, while
Stereo A is occasionally selected to monitor a cue track. To select both inputs, press
and hold the button associated with Surround A, then press Surround B’s button,
then release both buttons. Surround A and
B are now selected for monitoring. To monitor Stereo A press the button associated
with it. To return to monitoring Surround
A and B, simply press Stereo A’s button
again. The recall feature has returned the
system to the previously selected inputs.
That’s all there is to it!
A special configuration mode allows an input to be disabled. This would be appropriate if an input is not connected to an audio
source. If you press an input source button
and the previously selected input source
does not change, the newly selected input
has been disabled.
Downmix
Two downmix functions allow an operator to perform “real-world” compatibility
checks. They can also be referred to as
format functions because they allow conversion between various audio formats,
e.g., 5.1 (surround) signals converted
Model 74/75 User Guide
Studio Technologies, Inc.
for Surround
to stereo or stereo signals converted to
mono. How these functions affect the audio
signals will greatly depend on how the
Model 75 is configured. Being aware of the
selected configuration will allow the functions to serve a more useful role.
5.1 to Stereo
The 5.1 to stereo downmix function allows
surround signals to be mixed or “folded
down” into a stereo (left and right) signal.
Phase relationships and inter-channel level
issues can be quickly observed. Please
refer to the Technical Notes section of this
guide for a detailed description of how the
5.1 to stereo function mixes the surround
sources to stereo.
Using the 5.1 to stereo function simply
requires the button labeled Downmix
Stereo to be pressed. The button is always
set to “latch” the function on and off. The
associated LED lights when the function is
enabled. The stereo signal created by the
5.1 to stereo downmix function is routed to
the left and right channels of the selected
monitor output.
Depending on how the Model 75 Control
Console is configured, the 5.1 to stereo
downmix function may automatically enable whenever the stereo to mono downmix function is enabled. This is provided
to ensure an operator hears a valid mono
signal when a surround source is selected
as an input.
Stereo to Mono
The operating characteristics of the stereo
to mono downmix function depend on the
Model 75 Control Console’s configuration.
Two stereo to mono downmix modes are
available, as are four attenuation levels.
In the mono-to-left-and-right mode the
function combines (sums) the signals on
Model 74/75 User Guide
Studio Technologies, Inc.
the left and right channels and routes the
result to both the left and right channels
of the selected monitor output. This method is the same as found on many stereooriented audio consoles. Useful for music
mixing, it’s not true monaural but rather
binaural.
The mono-to-center mode of the stereo to
mono downmix function combines (sums)
the left and right channels and routes the
result to the center channel of the selected
monitor output. This function allows a more
accurate reproduction of a mono signal,
but may not be suitable for all operators.
To enable the stereo to mono downmix
function simply requires the button labeled
Downmix Mono to be pressed. The button
is always set to “latch” the function on and
off. The associated LED will light whenever
the function is enabled.
Bandpass Filter for Mono-to-Center
Mode
A special feature has been included to assist an operator in determining compatibility with “real-world” playback environments.
A bandpass filter can be inserted into the
path of the stereo to mono downmix signal when it is being routed to the center
channel. This allows the simulation of the
response of a loudspeaker associated with
an inexpensive monaural television or portable radio. The filter passes signals in the
range of 100 Hz to 5 kHz, while rejecting
those above and below.
To highlight for clarity, the bandpass filter
is only available for use when the stereo
to mono downmix function has been configured for the mono-to-center mode. For a
detailed technical description of the bandpass filter please refer to the Technical
Notes section of this guide.
Issue 3, November 2016
Page 35
for Surround
To enable the bandpass filter feature
requires knowing a “secret” button push
method. But it’s not much of a secret, as
you simply press and hold the downmix
mono button for two seconds to enable the
function. From that point forward, whenever the stereo to mono downmix function
is enabled the bandpass filter will also be
enabled. To indicate that the bandpass filter is enabled, the LED associated with the
downmix mono button will flash whenever
its associated function is enabled. To disable the bandpass function, press and hold
the downmix mono button for two seconds.
The change will be indicated by the LED,
which will now light steadily whenever
the stereo to mono downmix function is
enabled.
Monitor Output Functions
Four buttons and one rotary control are
associated with the monitor output functions. The buttons control operation of the
speaker system selection, reference level,
mute all, and dim. The rotary level control
is used to manually set the monitor output
level.
Speaker Systems
One button allows selection between
speaker system A and speaker system B.
There are two LEDs associated with the
function, providing a visual display of the
active system. It’s important to remember that the performance of the speaker
systems is installation specific. Using the
Model 75’s configuration choices, the
monitor output channels associated with
speaker system A and speaker system B
are selected.
Note that the Model 75 Control Console
can be configured to disable either of the
monitor outputs. If the monitor button is
Issue 3, November 2016
Page 36
pressed and nothing happens, this must
be the case!
Reference Level
The reference level button, labeled Ref
Level, sets the monitor output level to a
preset value. This level is normally set
by a technician, using a sound pressure
level (SPL) meter, at the time of system
installation. The LED associated with the
reference level function lights whenever
the function is active. Whenever reference
level mode is active the rotary level control
is disabled.
The reference level LED also serves as a
calibration aid. If the reference level mode
is not active and the rotary level control
is set at precisely the same level as that
stored for the reference value, the reference level LED will flash.
Mute All
The mute all function is highly complicated
to operate—not! Pressing the mute all button causes the monitor outputs to mute.
The mute all button is always set to “latch”
the function on and off. The LED associated with the mute all button will light whenever mute all is active. Note that if mute all
is enabled via the remote mute all function,
the mute all LED will flash.
Dim
The dim function is quite self-explanatory.
Press the dim button to enable the dim
mode, which reduces the monitor output
level by a preset amount. The dim button
is always set to “latch” the function on and
off. Dim activity applies no matter whether
the monitor output level is being set by the
rotary control or the reference button. The
dim level can be configured for 10, 15, 20,
or 25 dB, so one of those values will apply
Model 74/75 User Guide
Studio Technologies, Inc.
for Surround
when dim is active. The LED associated
with the dim button will light whenever dim
is active.
Other functions can also cause the dim
function to enable. Depending on how the
Model 75 is configured, it may also enable
whenever the talkback function is active.
The remote dim function allows a hardwired control signal to enable dim. If dim
is enabled via remote dim, the dim LED
will flash.
If the auto dim off function is enabled,
whenever dim is on and the rotary level
control is changed, dim will automatically
return to the off state. However, auto dim
off will not occur if the rotary control is
changed while either the talkback or remote dim functions are active. This ensures that the talkback function and the
external equipment controlling the remote
dim input will function appropriately.
Rotary Level Control
The rotary level control is used to manually
adjust the monitor output level. It is active
any time the reference level function is not
active. When the rotary level control is set
to give the same output level as the preset
reference level, the reference level LED will
flash.
By default, when the rotary level control is
set to its fully counterclockwise position,
the monitor output channels automatically
mute. This feature is provided for those
users accustomed to having a completely
quiet output when the level control is set
to its minimum position.
A Model 75 configuration parameter allows the level control’s automatic mute all
function to be disabled. When disabled,
the rotary level control simply adjusts the
monitor output level over its approximately
Model 74/75 User Guide
Studio Technologies, Inc.
72 dB of range. When the control is in its
fully counterclockwise position, low level
audio signals can be present on the monitor
outputs. This level control operating mode
may be preferable for those users who do
not like the abrupt level change that occurs
when the automatic mute all function activates. When the automatic mute all function
is disabled, the mute all button can be used
to achieve a full monitor output mute.
Mute/Solo
The mute/solo mode button and the six
monitor output channel buttons, along with
associated LEDs, work together to provide
excellent operating flexibility. The mute/solo
mode switch allows the operator to select
between mute and solo functions. Going
from mute mode to solo mode, or viceversa, clears all active mutes or solos.
Pressing the mode switch twice is a legitimate means of quickly clearing muted or
soloed channels.
In the mute mode, multiple channels can
be muted simultaneously. A channel that
is muted has its associated LED turned on.
The solo mode can operate in one of two
ways: additive or exclusive. How solo operates follows the configuration set in the
Model 75 Control Console. In additive solo
mode, multiple channels can be soloed
simultaneously. A channel that is soloed
has its associated LED flash on and off,
while the LEDs on the non-soloed channels
are not lit.
As expected, in the exclusive solo mode
pressing a channel button will cause that
channel to be soloed. But, in addition, any
other channel or channels being soloed
will go back to their normal, non-solo
condition. Thus the exclusive solo mode
allows rapid “soloing” of individual channels.
Should more than one channel need to be
Issue 3, November 2016
Page 37
for Surround
simultaneously soloed, simply push and
hold a channel button, then add the extra
channels by momentarily pressing their
buttons.
audio source or it will replace (interrupt)
the source. Note that it’s also possible to
configure the system so that no cue audio
source will be present at any time.
Headphone Cue System/Talkback
The headphone cue system and its associated talkback function is simple to use, but
does offer a number of user and configuration options. On the Model 75, three buttons and one LED are used to control these
functions.
A Model 75 function allows the cue audio
source to be selected from between two
choices. The first choice is the left and
right audio channels being sent to the
monitor outputs. These channels are post
(after) the input source buttons and the
downmix functions; whatever is being
heard out of the left and right monitor loudspeakers will be heard in the headphone
cue system. The second cue audio choice
is Stereo B. If this choice is selected, the
source or sources selected for the monitor outputs will have no impact on what is
heard in the headphone cue system.
The talkback button on the Model 75 is used
to enable the talkback function. Depending
on the Model 75’s configuration, the button may provide a push-to-talk or a latching
(push on/push off) action. In most cases
enabling the talkback function will also
cause the dim function to enable. However,
be aware that a Model 75 configuration
does allow talkback to not enable dim. The
LED associated with the talkback button will
light whenever talkback is enabled using the
button on the Model 75. Remotely enabling
talkback, using a hard-wired connection or
an infrared (IR) source, will cause the talkback LED to flash.
By using the two talkback level buttons,
the talkback level can be selected over an
8-step range. To adjust the talkback level,
enable the talkback function and press the
up or down button as required. The LED
associated with the talkback button will flash
each time the level is increased or decreased until the top or bottom of the range
is reached. At this point, if you continue to
press the same level button the LED won’t
flash, indicating you’re at the top or bottom
of the 8-step level range.
Depending on how the talkback function
has been configured, talkback audio will
either add to (sum with) the selected cue
Issue 3, November 2016
Page 38
It’s a simple matter to determine which
cue audio source is selected and, if desired, change to the other one. When the
talkback function is not active, press both
the talkback level up and level down buttons. The four input source LEDs will no
longer reflect the selected monitor source
(or sources) but instead will display the
selected cue audio source. Observing the
LED associated with Stereo B, if it is not lit
the cue audio source is the left and right
channels being sent to the monitor outputs.
If the LED associated with Stereo B is
flashing, the cue audio source is Stereo B.
To change the selected cue audio source,
press the Stereo B button.
Note that the Model 75 doesn’t provide an
overall level adjustment for the cue audio
and talkback output signals that are sent
to the talent amplifier and line-level cue
outputs. As was previously discussed, the
relative level of the talkback audio versus
the cue audio can be adjusted. This reflects the StudioComm’s system architecModel 74/75 User Guide
Studio Technologies, Inc.
for Surround
ture and isn’t a design deficiency. The overall
level for a pair of headphones connected to
a Model 35 Talent Amplifier is adjusted using
the Model 35’s level control. A headphone
cue system connected to the Model 74’s
line-level cue output must have its own level
controls.
Remote Controls
Four hard-wired remote control signals
can be connected to the system and configured for the desired operating characteristics: mute all, dim, talkback, and input select.
In addition, an infrared (IR) receiver can be
connected to allow wireless activation of the
talkback function.
When remote mute all is activated the LED
on the Model 75 associated with mute all
will flash. If mute all was already active
when the remote mute all function is activated, the LED will change from being steadily
lit to flashing.
When remote dim is activated the LED on
the Model 75 associated with the dim function will flash. If dim was already active when
remote dim is activated, the LED will change
from being steadily lit to flashing.
When remote talkback is activated, either
via a hard-wired connection or an infrared
(IR) signal, the LED on the Model 75 associated with the talkback function will flash.
If dim was already active when remote talkback is activated, the LED will change from
being steadily lit to flashing.
When remote input select is activated, the
LED on the Model 75 associated with the
selected input will flash. If the function is set
for exclusive, no other LEDs will be lit. If the
function is set for non-exclusive, the LED
associated with remote input select will
flash, while the LEDs associated with any
other active inputs will remain steadily lit.
Model 74/75 User Guide
Studio Technologies, Inc.
Model 35 Talent Amplifier
Up to four Model 35 Talent Amplifiers can
be connected to a Model 74. The power
present LED on each Model 35 should be
lit whenever it’s connected to a poweredup Model 74. The user is provided with a
rotary level control, stereo/mono button,
and two ¼-inch 3-conductor (stereo) headphone jacks. One or two pairs of headphones with a total impedance of 75 ohms
or greater can be connected. Adjust the
control to achieve the desired output level.
To highlight, the headphone output level is
only adjusted using the Model 35’s rotary
control; there are no headphone level adjustments available on the Model 75. Using
the button the output can be selected for
stereo or mono. When selected for mono,
the left and right channels are combined
(summed) and routed to both the left and
right outputs.
Warning: Protect your ears! The
Model 35 Talent Amplifier is capable
of driving headphones to extremely
high sound pressure levels. Hearing
experts advise against continuous extended play, especially at high levels.
Technical Notes
Downmix
The downmix functions are implemented in
the Model 74 Central Controller’s hardware
using analog circuitry. From the factory
5.1 to stereo downmix is defined as: center dropped in level by 6 dB and routed
to left and right; left surround dropped in
level by 3 dB and routed to left; right surround dropped in level by 3 dB and routed
to right; LFE muted. By making simple
Issue 3, November 2016
Page 39
for Surround
resistor changes the level changes can be
easily revised. In addition, provision has
been made to allow the LFE signal to be
routed to the left and right channels during
downmix.
While no soldering is required, a competent technician is required to perform any
changes to the downmix function. This will
help to ensure a safe and successful modification. Page 5 of the Model 74 schematic
contains the circuitry that implements the
downmix function. Please contact the factory for a copy of the schematic.
ceived from the factory, one 22 k ohm 6-pin
single-inline-package (SIP) resistor is used
to configure the filter for nominally 100 Hz.
To revise the high-pass frequency this SIP
resistor can be replaced. The SIP resistor
must be an isolated-terminal-type, providing
three independent resistors in one assembly.
Alternately, using ¼-watt 1%-tolerance resistors is appropriate.
A simple formula is used to determine the
resistance required for a specific filter frequency: R = 2,250,000 ÷ F, where R is resistance in ohms and F is frequency in hertz.
Bandpass Filter
Low-Pass Filter
The bandpass filter associated with the
mono-to-center downmix mode is created
by cascading (connecting in series) a
high-pass and a low-pass active filter.
Each filter is a Sallen-Key type, with a
12 dB-per-octave response. The high-pass
filter has a nominal –3 dB point at 100 Hz;
the low-pass at 5 kHz. For a detailed description of the filters, refer to page 5 of
the Model 74 schematic diagram.
Components were selected at the factory
so that the low-pass filter section’s output
has a –3 dB point of nominally 5 kHz. (To
be more precise, the math calculations work
out to be 5.25 kHz.)
High-Pass Filter
Components were selected at the factory
so that the high-pass filter section’s output
has a –3 dB point of nominally 100 Hz. (To
be more precise, the math calculations
work out to be 102 Hz.) For some applications it may be optimal to adjust this frequency. The Model 74 makes this a simple
task, with no soldering or complicated
procedures required. Refer to page 5 of
the schematic for details.
The frequency of the high-pass filter is
configured by means of three resistors,
each identical in value. A 6-position socket,
located on the Model 74’s printed circuit
board, is used to hold the resistors. As reIssue 3, November 2016
Page 40
The frequency of the low-pass filter is
configured by means of two ¼-watt, 1%tolerance resistors, each identical in value.
One 6-pin socket, located on the Model 74’s
printed circuit board, is used to hold the
resistors. From the factory, two 14.3 k ohm
resistors configure the filter for nominally 5
kHz. One resistor is inserted into socket pins
1 and 2, the second into pins 3 and 4. To
revise the frequency, these can be replaced
with two other resistors, or one 6-pin SIP
resistor package. It’s important to note that
the SIP resistor must be an isolated-terminal-type, providing three independent resistors in one assembly. For details refer to
page 5 of the Model 74 schematic diagram.
A simple formula is used to determine
the resistance required for a specific filter
frequency: R = 75,000,000 ÷ F, where R is
resistance in ohms and F is frequency in
hertz.
Model 74/75 User Guide
Studio Technologies, Inc.
for Surround
Monitor Output Gain
Structure
“Hot” Disconnection of the
Model 75 Control Console
The Model 74 Central Controller’s monitor
outputs are configured for unity gain. When
the rotary level control on the Model 75
Control Console is set for maximum level
(fully clockwise) the output level is essentially the same as the input level. The input
trim potentiometers allow precise adjustment of the input circuitry. This was provided so that level variations in input sources,
the Model 74’s circuitry, and the associated
power amplifiers can be “trimmed out.”
Should you need to relocate the Model 75
while your StudioComm system is operating, there is no reason why you can’t
disconnect the cable, move the unit, and
then reconnect the cable. If the Model 75
is disconnected while it is operating, the
active operating parameters are saved in
non-volatile memory and the Model 74
Central Controller will continue to operate as before the connection was broken.
No clicks, pops, or other noises will occur
when the Model 75 is again connected.
The Model 75 will go through its standard
power-up sequence, send a message to
reset power-up defaults, then send the
operating parameters as are stored in its
memory. Depending on its configuration
settings vis-à-vis power-up, the Model 74’s
monitor outputs may be placed in their
mute mode.
Definition of Levels
Whenever possible, when describing audio
signal levels Studio Technologies has opted to use the dBu designation as it seems
to be quite rational. The dBu designation
refers to dB referenced to 0.775 V, with no
reference to load impedance. This takes
into account today’s audio scene where
signals have a low source impedance and
a high input impedance.
The Model 74 is designed to interface
with audio signals that have nominal signal levels of –12 dBV to +6 dBu. You might
wonder why “dBV” came into the picture.
Most people don’t realize that equipment
that utilizes “–10” levels usually mean
–10 dBV—substantially different from
–10 dBu (–10 dBV = –7.78 dBu). The dBV
designation is simply a different way of
measuring signal level and is often used
when dealing with portable or consumer
audio equipment. The dBV designation
refers to dB referenced to 1.0 V, rather
than dBu which refers to 0.775 V.
Model 74/75 User Guide
Studio Technologies, Inc.
Monitor Output Transient
Protection
The Model 74 Central Controller contains
a power up/power down protection feature. This limits the chance of damage to
the monitor loudspeakers during the time
when AC mains voltage is connected,
disconnected, or has dropped significantly
from nominal. During testing it was found
that upon power up the monitor outputs
remained very quiet; during power down
a moderate “tick” was the worst that was
heard. A combination of hardware and
software is used to monitor one “rail” of
the internal power supply. Upon initial
connection of AC mains power electromechanical relays maintain a short circuit
condition on the monitor outputs. If the
AC mains input voltage exceeds 90% of
Issue 3, November 2016
Page 41
for Surround
nominal for approximately four seconds
the relays are allowed to function normally. Whenever the AC mains input voltage drops below approximately 85% of
nominal the relays immediately go to their
mute state. The Model 74 will stay in this
low-voltage state unit the AC mains voltage has again exceed 90% of nominal for
approximately four seconds. Any time the
Model 74 is in the low-voltage state the
power LED, located on the front panel, will
flash.
Mono-to-Center Polarity
It’s worthwhile to note that a polarity inversion takes place whenever the stereo
to mono downmix’s mono-to-center function is active. By design, the input signals
experience a 180-degree inversion in the
Model 74’s mono-to-center combining
circuitry. This should not cause a problem
as monitoring audio signals over a single
loudspeaker is considered polarity insensitive. Only during electrical testing would
this condition be detected.
Talent Amplifier Cable Length
There are no hard and fast rules defining
the maximum cable length when connecting Model 35 Talent Amplifiers to the Model
74 Central Controller. The maximum cable
length is directly related to the amount of
resistance in the connecting cable; the
lower the resistance per foot (or meter),
the longer the cable can be. (Although
cable capacitance affects high frequency
performance, resistance is the limiting factor is this case.)
To lay out the facts in grammar-school
story problem format: for correct operation,
a Model 35 needs to see at least 20 volts
DC between pins 1 and 2 of their input
Issue 3, November 2016
Page 42
connector. The Model 74’s talent amplifier
output voltage across pins 1 and 2 is 27
volts DC, with a maximum current draw of
200 milliamperes. This difference between
the voltage supplied and the voltage required results in a maximum voltage drop
of 7 volts over the interconnecting cables.
Since cable is rated in ohms per 1000
feet (or ohms per 1000 meters), you need
to know what the maximum cable resistance is. This can be easily calculated by
dividing the maximum voltage drop by the
maximum current flow: 7 volts divided by
200 milliamperes (0.2 A) = 35 ohms. For
example, a standard 20 AWG microphone
cable is Belden 8412, which has 10.9
ohms resistance per conductor per 1000
feet. Since we’re using two conductors to
carry the signal (pins 1 and 2) you’d get
21.8 ohms per 1000 feet of microphone
cable. With our 35 ohm maximum resistance you’d be able to use 1600 feet (492
meters) of this cable.
By using the numbers provided you can
select a cable, and its maximum length,
for your application.
Model 74 to Model 75
Connections
Figure 11 gives a detailed view of
the signals that connect between the
Model 74 Central Controller and the Model
75 Control Console. The Model 74 provides +15 volt DC power for the Model 75.
The Model 75 generates MIDI systemexclusive messages and sends them to the
Model 74. From the outside world, the four
hard-wired remote control input sources
connect to the Model 74. They then route,
via the interface cable, from the Model 74
to the actual input circuitry, located in the
Model 75.
Model 74/75 User Guide
Studio Technologies, Inc.
for Surround
It should be noted that the infrared (IR)
remote talkback circuit “tags along” with
the hard-wired remote talkback input. An
IR receiver module connects via input
circuitry to the Model 74’s microcontroller
integrated circuit. Under software control
IR-generated requests for talkback are
decoded. A logic output pin on the microcontroller goes to logic high (+5 volts
DC) whenever talkback is detected. This
signal drives the input of an optocoupler
integrated circuit. The optocoupler’s output
transistor is connected directly across pin
7 (remote talkback) and pin 9 (ground) on
the two 9-pin D-subminiature connectors.
In this way the IR talkback input is “OR’d”
(connected in parallel) with the hard-wired
remote talkback input. The signal reaches
the Model 75 Control Console where it
performs the talkback function. The Model
75 doesn’t have the logic to recognize a
remote talkback signal that is generated by
a hard-wired connection or a IR request.
Spare Remote Control Inputs
Figure 10 lists two spare (unused) remote
control inputs. These inputs are provided
for future special applications. It’s interesting to note that they are quite unlike
the four hard-wired remote control inputs.
Inside the Model 74, the four hard-wired
remote control inputs are directly routed
to the connector that links to the Model
75 Control Console. The microcontroller
in the Model 75 monitors and acts upon
those four signals. The two spare inputs
stay within the Model 74, connecting to
input ports on the Model 74’s microcontroller; they do not connect to the Model
75. Inside the Model 74 these spare inputs
are “pulled” to logic high (5 volts) and ESDprotected prior to connecting to the Model
74’s microcontrollers.
Model 74/75 User Guide
Studio Technologies, Inc.
Issue 3, November 2016
Page 43
for Surround
Specifications
Model 74 Central Controller
General Audio:
Frequency Response: 20 Hz-20 kHz ±0.1 dB
(down 0.5 dB @ 60 kHz), monitor outputs
Distortion (THD+N): 0.04%, measured at 1 kHz,
+4 dBu, monitor outputs
Line-Level Talkback Input:
Level: +4 dBu, nominal
Type: electronically balanced
Impedance: 24 k ohms, nominal
Infrared Receiver Input:
Type: intended for use with industry-standard
receiver module; data rate 650 baud
Remote Control Inputs: 4
S/N Ratio: 87 dB, ref +4 dBu out, 20 Hz-20 kHz,
monitor outputs
Type: +5 volts DC logic, activates on closure to
system common
Crosstalk: 78 dB, typical, ref +4 dBu in,
20 Hz-20 kHz, monitor outputs
Functions: mute, dim, talkback, input select
Audio Inputs: 16, organized as two 6-channel “5.1”
inputs and two 2-channel “stereo” inputs
Type: electronically balanced, compatible with
balanced or unbalanced sources
Impedance: 24 k ohms
Nominal Level: –12 dBV to +6 dBu, adjustable
Level Calibration: 15-turn trim potentiometers
Monitor Outputs: 2, 6-channel
Type: electronically balanced, compatible with
balanced or unbalanced loads
Maximum Level: +27 dBu into 10 k ohms, +26 dBu
into 600 ohms
Talent Amplifier Output:
Compatibility: provides power and audio signals
for up to four Model 35 Talent Amplifiers
Downmix:
Functions: 5.1 to stereo, stereo to mono (monoto-left-and-right, mono-to-center)
5.1 to Stereo: LS @ –3 dB summed with L; RS @
–3 dB summed with R, C @ –6 dB summed with
L and R; LS, RS, and sub monitor outputs mute
Stereo to Mono (Mono-to-Left-and-Right):
L summed with R to L and R or L summed with R
to C; attenuation independently configurable; C, LS,
RS, and sub monitor outputs mute
Stereo to Mono (Mono-to-Center): L summed
with R to C; attenuation independently configurable;
L, R, LS, RS, and sub monitor outputs mute
Stereo to Mono (Mono-to-Center) Bandpass
Filter:
Response: –3 dB @ 100 Hz and 5 kHz, nominal,
12 dB/octave
Type: DC power with two channels of unbalanced
audio
Connectors:
Connections: common on pin 1, DC (+27 volts
nominal, 200 milliamperes maximum) modulated
with channel 1 audio (–10 dBu nominal) on pin 2,
and channel 2 audio (–10 dBu nominal) on pin 3
Talent Amplifier Output: 3-pin male XLR
Line-Level Cue Output: 1, stereo
Nominal Level: +4 dBu, nominal
Type: electronically balanced, capacitor-coupled,
intended to drive balanced or unbalanced loads of
600 ohms or greater
Source Impedance: 100 ohms, nominal
Maximum Level: +20 dBu into 10 k ohms
Issue 3, November 2016
Page 44
Audio: 4, 25-pin female D-subminiature (DE-25F)
To/From Model 75: 9-pin female D-subminiature
(DE-9F)
Remote Control Inputs: 9-pin female D-subminiature (DE-9F)
Infrared Receiver Input: 3.5 mm 3-conductor jack
AC Mains: 3-blade, IEC 320 C14-compatible
(mates with IEC 320 C13)
AC Mains Requirement:
100, 120, or 220/240 V, ±10%, factory configured,
50/60 Hz, 26 watts maximum
Model 74/75 User Guide
Studio Technologies, Inc.
for Surround
Dimensions (Overall):
19.00 inches wide (48.3 cm)
1.72 inches high (4.4 cm)
9.58 inches deep (24.3 cm)
Mounting: one space (1U) in a standard 19-inch
rack
Weight: 9.5 pounds (4.3 kg)
Model 75 Control Console
Application: supports Model 74 Central Controller
Power: provided by Model 74 Central Controller
Output Data: generates MIDI system-exclusive
messages
Connector: 9-pin female D-subminiature (DE-9F)
Dimensions (Overall):
7.2 inches wide (18.3 cm)
2.2 inches high (5.6 cm)
5.4 inches deep (13.7 cm)
Weight: 1.8 pounds (0.82 kg)
Model 35 Talent Amplifier
Load: intended for connection to one or two pairs
of headphones with total impedance of 75 ohms or
greater
Appendix A
Controlling the Model 74
The Model 74 Central Controller uses MIDI
system-exclusive messages to control all
functions. The Model 75 Control Console
is programmed to generate a subset of
what the Model 74 is capable of doing.
By using standard MIDI messages, the
Model 74 can be used for a wide range of
special applications. Any device that can
be programmed to send system-exclusive
MIDI messages can be used to control the
Model 74.
General Notes
All MIDI messages to be acted upon are
system-exclusive type (F0H). No channel
mode, system common, or system real
time messages are utilized.
Studio Technologies, Inc. manufacturer’s
ID number is 00H 00H 56H.
The Model 74’s product device ID number
is 07H.
Maximum Output Voltage: 16 V peak-to-peak into
150 ohms @ 1% THD+Noise
Distortion (THD+N): 0.03%
Frequency Response: 20 Hz-20 kHz ±0.5 dB
Dimensions (Overall):
4.2 inches wide (10.7 cm)
2.0 inches high (5.1 cm)
5.3 inches deep (13.5 cm)
Weight: 0.8 pounds (0.7 kg)
Specifications and information contained in this
User Guide subject to change without notice.
Model 74/75 User Guide
Studio Technologies, Inc.
Issue 3, November 2016
Page 45
for Surround
Function: Reset to Power Up Default Configuration
Byte
Value
Description
1
F0H
System-Exclusive Message
2
00H
1st Byte of Studio Tech ID
3
00H
2nd Byte of Studio Tech ID
4
56H
3rd Byte of Studio Tech ID
5
07H
Product ID (Model 74)
6
00H
Function, Restore Power Up Default Configuration
7
F7H
EOX, End of System-Exclusive Message
Notes: Action taken after message is received:
Set all input sources to off.
Set all monitor output channels to off.
Set monitor output level to minimum.
Set stereo to mono downmix function to off.
Set 5.1 to stereo downmix function to off.
Issue 3, November 2016
Page 46
Model 74/75 User Guide
Studio Technologies, Inc.
for Surround
Function: Input Source and Associated Channels
Byte
Value
Description
1
F0H
System-Exclusive Message
2
00H
1st Byte of Studio Tech ID
3
00H
2nd Byte of Studio Tech ID
4
56H
3rd Byte of Studio Tech ID
5
07H
Product ID (Model 74)
6
01H
Function, Input Source and Associated Channels
7
0nH
Input Source, range 1-4:
1=Surround A
2=Surround B
3=Stereo A
4=Stereo B
8
nnH
Input Channel Status Bit Map (sum values from all six channels):
Channel 1 (L): off=00; on=01
Channel 2 (R): off=00; on=02
Channel 3 (C): off=00; on=04
Channel 4 (LFE): off=00; on=08
Channel 5 (LS): off=00; on=10
Channel 6 (RS): off=00; on=20
9
F7H
EOX, End of System-Exclusive Message
Note:
Inputs 3 and 4 only have input channels 1 (L) and 2 (R) associated with them.
Channels 3 (C), 4 (LFE), 5 (LS), and 6 (RS) are not physically present on inputs
3 and 4.
Model 74/75 User Guide
Studio Technologies, Inc.
Issue 3, November 2016
Page 47
for Surround
Function: Monitor Output Channel Status
Byte
Value
Description
1
F0H
System-Exclusive Message
2
00H
1st Byte of Studio Tech ID
3
00H
2nd Byte of Studio Tech ID
4
56H
3rd Byte of Studio Tech ID
5
07H
Product ID (Model 74)
6
02H
Function, Monitor Output Channel Status
7
nnH
Monitor Output A Channel Status using Output Relays
Bit Map (sum values from all six channels):
Channel 1 (L): off=00; on=01
Channel 2 (R): off=00; on=02
Channel 3 (C): off=00; on=04
Channel 4 (SUB): off=00; on=08
Channel 5 (LS): off=00; on=10
Channel 6 (RS): off=00; on=20
8
nnH
Monitor Output B Channel Status using Output Relays
Bit Map (sum values from all six channels):
Channel 1 (L): off=00; on=01
Channel 2 (R): off=00; on=02
Channel 3 (C): off=00; on=04
Channel 4 (SUB): off=00; on=08
Channel 5 (LS): off=00; on=10
Channel 6 (RS): off=00; on=20
9
nnH
Monitor Output Channel Status using Input Analog Switches
Bit Map (sum values from all six channels):
Channel 1 (L): normal=00; mute=01
Channel 2 (R): normal=00; mute=02
Channel 3 (C): normal=00; mute=04
Channel 4 (LFE): normal=00; mute=08
Channel 5 (LS): normal=00; mute=10
Channel 6 (RS): normal=00; mute=20
10
F7H
EOX, End of System-Exclusive Message
Issue 3, November 2016
Page 48
Model 74/75 User Guide
Studio Technologies, Inc.
for Surround
Function: Monitor Output Level - Normal
Byte
Value
Description
1
F0H
System-Exclusive Message
2
00H
1st Byte of Studio Tech ID
3
00H
2nd Byte of Studio Tech ID
4
56H
3rd Byte of Studio Tech ID
5
07H
Product ID (Model 74)
6
03H
Function, Monitor Output Level - Normal
7
nnH
Monitor Output Level, MSB, range 00-7F
8
0nH
Monitor Output Level, LSB, range 0-1
9
F7H
EOX, End of System-Exclusive Message
Notes: Control console sends new value each time monitor output level is changed.
Monitor output level is 8-bit precision, spread over two MIDI bytes: 00H 00H lowest;
7FH 01H highest. MIDI byte 7 is monitor output level bits 2-8; MIDI byte 8 is
monitor output level bit 1.
Dim function is performed by control console and is sent using monitor output level
command.
Model 74/75 User Guide
Studio Technologies, Inc.
Issue 3, November 2016
Page 49
for Surround
Function: Monitor Output Level - Reverse
Byte
Value
Description
1
F0H
System-Exclusive Message
2
00H
1st Byte of Studio Tech ID
3
00H
2nd Byte of Studio Tech ID
4
56H
3rd Byte of Studio Tech ID
5
07H
Product ID (Model 74)
6
04H
Function, Monitor Output Level - Reverse
7
nnH
Monitor Output Level, MSB, range 00-7F
8
0nH
Monitor Output Level, LSB, range 0-1
9
F7H
EOX, End of System-Exclusive Message
Notes: Not sent by control console. Provided for special applications.
Monitor output level is 8-bit precision, spread over two MIDI bytes: 00H 00H highest;
7FH 01H lowest. MIDI byte 7 is monitor output level bits 2-8; MIDI byte 8 is monitor
output level bit 1.
Dim function is performed by control console and is sent using monitor output level
command.
Issue 3, November 2016
Page 50
Model 74/75 User Guide
Studio Technologies, Inc.
for Surround
Function: Stereo to Mono Downmix
Byte
Value
Description
1
F0H
System-Exclusive Message
2
00H
1st Byte of Studio Tech ID
3
00H
2nd Byte of Studio Tech ID
4
56H
3rd Byte of Studio Tech ID
5
07H
Product ID (Model 74)
6
05H
Function, Stereo to Mono Downmix
7
0nH
Status, range 0-3:
0=off
1=on, L+R sent to left and right channels of monitor output
2=on, L+R sent to center channel of monitor output
3=on, Bandpassed L+R sent to center channel of monitor output
8
F7H
EOX, End of System-Exclusive Message
Model 74/75 User Guide
Studio Technologies, Inc.
Issue 3, November 2016
Page 51
for Surround
Function: 5.1 to Stereo Downmix
Byte
Value
Description
1
F0H
System-Exclusive Message
2
00H
1st Byte of Studio Tech ID
3
00H
2nd Byte of Studio Tech ID
4
56H
3rd Byte of Studio Tech ID
5
07H
Product ID (Model 74)
6
06H
Function, 5.1 to Stereo Downmix
7
0nH
Status, range 0-1:
0=off
1=on
8
F7H
EOX, End of System-Exclusive Message
Issue 3, November 2016
Page 52
Model 74/75 User Guide
Studio Technologies, Inc.
for Surround
Function: Cue Audio
Byte
Value
Description
1
F0H
System-Exclusive Message
2
00H
1st Byte of Studio Tech ID
3
00H
2nd Byte of Studio Tech ID
4
56H
3rd Byte of Studio Tech ID
5
07H
Product ID (Model 74)
6
07H
Function, Cue Audio
7
0nH
Cue Audio Source:
0=No Source
1=Stereo B
2=Source follows L/R Output
8
F7H
EOX, End of System-Exclusive Message
Model 74/75 User Guide
Studio Technologies, Inc.
Issue 3, November 2016
Page 53
for Surround
Function: Talkback
Byte
Value
Description
1
F0H
System-Exclusive Message
2
00H
1st Byte of Studio Tech ID
3
00H
2nd Byte of Studio Tech ID
4
56H
3rd Byte of Studio Tech ID
5
07H
Product ID (Model 74)
6
08H
Function, Talkback
7
0nH
Talkback Level, range 0-7, 7 is loudest
8
0nH
Talkback Status:
n=0 Off
n=1 On, Source is Model 75 Mic
n=2 On, Source is Line-Level Talkback Input
9
F7H
EOX, End of System-Exclusive Message
Issue 3, November 2016
Page 54
Model 74/75 User Guide
Studio Technologies, Inc.
DIFFERENTIAL
LINE RECEIVER
ALL MONITOR OUTPUTS
+4dBu NOMINAL
ADJUSTABLE
GAIN BUFFER
LEVEL
CONTROL
BUFFER
L
L
TRIM
R
SURROUND
INPUT A
(-12dBV TO +6dBu)
R
DIFFERENTIAL
LINE DRIVER
VCA
5.1 TO
STEREO
DOWNMIX
MUTING/
ROUTING
RELAYS
OUTPUT A
MUTING/
ROUTING
RELAYS
OUTPUT A
MUTING/
ROUTING
RELAYS
OUTPUT A
MUTING/
ROUTING
RELAYS
OUTPUT A
MUTING/
ROUTING
RELAYS
OUTPUT A
MUTING/
ROUTING
RELAYS
OUTPUT A
L
OUTPUT B
STEREO
TO MONO
DOWNMIX &
BANDPASS
C
C
VCA
LFE
OUTPUT B
LFE
ANALOG
SWITCHES
LS
R
RS
LS
VCA
SURROUND INPUT B IDENTICAL TO SURROUND INPUT A
C
OUTPUT B
RS
L
STEREO INPUT A
(-12dBV TO +6dBu)
R
VCA
SUB
OUTPUT B
L
STEREO INPUT B
(-12dBV TO +6dBu)
R
VCA
VCA
+12IR
POWER
S
IR RECEIVER INPUT
(3.5mm JACK)
LS
OUTPUT B
RS
OUTPUT B
DATA
DATA
INTERFACE
T
R
CURRENT
SHARING
POWER
SUPPLY
+16V
TO/FROM
CONTROL
CONSOLE
(9-PIN D-SUB)
+V1
D/A OUT
8-BIT
MICROCONTROLLER
& SUPPORT
LOGIC
DATA
INTERFACE
TB AUDIO
REMOTE TB
3
REMOTE
CONTROL
INPUTS
(9-PIN D-SUB)
DATA BUS
OPTOCOUPLED
OUTPUT
+V2
GPI
INPUTS
A/D IN
2
FROM TALENT AMP
L
POWER
MODULATOR
[+27VDC W/L CH AUDIO @-10dBu NOMINAL]
A/D IN
[R CH AUDIO @-10dBu NOMINAL]
ANALOG
SWITCHES
A/D IN
TO A/D INPUT
2
3
1
OUTPUT TO
TALENT AMPLIFIERS
(XLR-M)
R
ANALOG
SWITCH
AUX TB
INPUT
CUE OUTPUT
(+4dBu)
L
AC MAINS
FACTORY CONFIGURABLE
FOR 100, 120, or 220/240V
50/60Hz OPERATION
FUSE
POWER
SUPPLY
1
POWER
SUPPLY
2
+15
+12
+5
-5
-15
+V2
+V1
+12IR
8-STEP
LEVEL
CONTROL
M74BD_B
STUDIO TECHNOLOGIES, INC.
R
MODEL 74
CENTRAL CONTROLLER
BLOCK DIAGRAM
DRAWING NO.
DATE
31162
03/17/08
PAGE
01
OF
01