Important: Note that the XSNet Series manuals may cover multiple models. To establish if a particular feature or specification in this manual applies to the unit at hand, consult the datasheet of the given model.
Quick Start Guide
This quick start guide describes how to install and use the Hardened Managed PoE (Power over Ethernet)
Ethernet Switch. This is the switch of choice for harsh environments constrained by space.
Physical Description
The Port Status LEDs and Power Inputs
Note: The EU Declaration of Conformity for this product can be found at www.siqura.com/support-files.
XSNet C4208SW
Functional Description
Meets EN61000-6-2 & EN61000-6-4 EMC Generic Standard Immunity for industrial environment.
RS-232 console, Telnet, SNMP v1 & v2c & v3, RMON, Web Browser, and TFTP management.
Supports Command Line Interface in RS-232 console.
Supports 8192 MAC addresses. Provides 2M bits memory buffer.
Port 1 ~ Port 4 support IEEE802.3at Power over Ethernet (PoE) Power Sourcing Equipment (PSE) and/or Port 5 ~ Port 8 support IEEE802.3af Power over Ethernet (PoE) Power Sourcing Equipment
(PSE).
Power Input Assignment
Power3 47-57VDC
+ 47-57VDC
Power2
- Power Ground
Power1
+ 47-57VDC
- Power Ground
Terminal
Block
Earth Ground
Relay Output Rating 1A @ 250VAC
Relay Alarm Assignment
FAULT
*Warning signal disable for following:
1. The relay contact closes if Power1 and
Power2 are both failed but Power3 on.
2. The relay contact closes if Power3 is failed but Power1 and Power2 are both on.
10/100Mbps-full/half-duplex, Auto MDI/MDIX.
The C4208SW PoE is equipped with 2x 1000Base-FX SFP slots.
Store-and-forward mechanism. Full wire-speed forwarding rate.
Alarms for power and port link failure by relay output.
Operating voltage and Max. current consumption: 0.31A @ 48VDC. Power consumption: Power consumption: 181.6W Max. (Full load with PoE), 15W Max. (Without PoE).
Field Wiring Terminal: Use Copper Conductors Only, 60/75°C, 12-24 AWG torque value 7 lb-in.
-40°C to 75°C (-40°F to 167°F) operating temperature range. Tested for functional operation @ -40°C to 85°C (-40°F to 185°F).
For use in Pollution Degree 2 Environment.
10/100Base-TX
LINK/ACT
Steady
Flashing
A valid network connection established.
Transmitting or receiving data.
ACT stands for ACTIVITY.
Steady Power Device (PD) is connected.
PoE
Off Power Device (PD) is disconnected.
1000Base SFP
LINK/ACT
Steady
Flashing
A valid network connection established.
Transmitting or receiving data.
ACT stands for ACTIVITY.
DC Terminal Block Power Inputs: There are two power inputs can be used to power up this switch.
Redundant power supplies function is supported.
Supports Din-Rail or Panel Mounting installation.
Console Configuration
Connect to the switch console:
Connect the DB9 straight cable to the RS-232 serial port of the device and the RS-232 serial port of the terminal or computer running the terminal emulation application. Direct access to the administration console is achieved by directly connecting a terminal or a PC equipped with a terminal-emulation program (such as HyperTerminal) to the switch console port.
Configuration settings of the terminal-emulation program:
Baud rate: 115,200bps
Data bits: 8
Parity: none
Stop bit: 1
Flow control: none
Press the “Enter” key. The Command Line Interface (CLI) screen should appear as below:
Logon to Exec Mode (View Mode):
At the “switch_a login:” prompt just type in “root” and press <Enter> to logon to Exec Mode (or View
Mode). And the “switch_a>” prompt will show on the screen.
1 V2
XSNet C4208SW
Web Configuration
Login the switch:
Specify the default IP address (192.168.1.10) of the switch in the web browser. A login window will be shown as below:
Logon to Privileged Exec Mode (Enable Mode):
At the “switch_a>” prompt just type in “enable” and press <Enter> to logon to Privileged Exec Mode (or
Enable Mode). And the “switch_a#” prompt will show on the screen.
Logon to Configure Mode (Configure Terminal Mode):
At the “switch_a#” prompt just type in “configure terminal” and press <Enter> to logon to Configure
Mode (or Configure Terminal Mode). And the “switch_a(config)#” prompt will show on the screen.
Set new IP address and subnet mask for Switch:
At the “switch_a(config)#” prompt just type in “interface vlan1.1” and press <Enter> to logon to vlan 1
(vlan1.1 means vlan 1). And the “switch_a(config-if)#” prompt will show on the screen.
Command Syntax: “ip address A.B.C.D/M”. “A.B.C.D” specifies IP address. “M” specifies IP subnet mask. “M”= 8: 255.0.0.0, 16:255.255.0.0, or 24: 255.255.255.0.
For example, At the “switch_a(config-if)#” prompt just type in “ip address 192.168.1.10/24” and press
<Enter> to set new IP address (192.168.1.10) and new IP subnet mask (255.255.255.0) for Switch.
Enter the factory default login ID: root.
Enter the factory default password (no password).
Then click on the “Login” button to log on to the switch.