ELECTRONICS CATALOGUE.cdr

ELECTRONICS CATALOGUE.cdr
ELECTRONICS
1
A.F. OSCILLATOR (BRIDGE EXPERIMENTS)
8
A fix frequency Oscillator for
Bridge Experiments, workable on
220 Volts 50 Hz, Giving variable
output 0 to 10 volts P-P at 1000
Hz. Accuracy ±2% Output
2
General use of instruments is in ultra
sound and letcher wire experiments.
Generate frequency 3 MHz with high
output volts. The frequency is
A.F. OSCILLATOR (FUNCTION GENERATOR)
Generates frequency from 1 Hz
to 250 KHz in 6 steps wave form
is sine square and Triangular.
Output is variable from 0 to 10
Volts Accuracy ± 3% or 2 Hz.
Output Impedance 50
ohms. Solid State. Workable on 220 v 50 Hz complete I.C.
version with coarse and fine controls for output and
3
9
10
A.F. OSCILLATOR (DIGITAL)
continuous variation in three
control.
coarse steps and a fine
12
R.F. OSCILLATOR
13
CRYSTAL MARKER GENERATOR
Instruments is standard frequency generator, workable 220V
50 Hz, crystal used is of fundamental frequency of 1 MHz,
Frequency output level is T.T.L. compatible. Four decade
dividing circuit is used to make it variable 1 Hz to 1 MHz.
7
CONDUCTIVITY BRIDGE
This instrument is to measure
Conductance of Electrolyte
solution or its Resistance directly.
Working frequencies are 50 Hz
and 1 KHz. Direct calibration in
MHO. Resistance 0.1 Ohms to 1
Meg ohms. Conductance 1 MHO
to 1 Micro Mhz
Ohms. The instrument is solid state and workable on 220
Volts 50 Hz. Sine, Square waves, Read out Digital.
Variable 100 KHz to 30 MHz. The
instrument is to deliver modulated
output and continuous wave form.
The frequency range is covered in
eight bands , modulation frequency is
400 Hz, and also available on output
PULSE GENERATOR
The instrument produces
rectangular pulses. The pulse
rate and the pulse width is
variable. The pulse amplitude
can be selected to trigger T.T.L.
Circuit. Specification :Pulse Time : 10 Micro sec. to 1 sec. variable
External Triggering : 2-20 Volts.
Pulse Width : 1 Micro sec. to 1 sec.
A.F. OSCILLATOR (FUNCTION GENERATOR) CUM DIGITAL
Frequency Meter Variable from 1
Hz to 1 MHz in five decade
ranges Accuracy ±2% or 1 Hz.
Six steps output 1 mV to 20V
open circuit, continuously
variable. Frequency response
±0.3 db from 20 Hz to 20 KHz.
Setting at KHz, 0-5 dB, 10 Hz
to100 KHz. Output Impedance
600
6
T.V. PATTERN GENERATOR (BLACK AND WHITE)
The instrument find application for
checking coloured T.V. Line frame,
time bass, linearity, picture,
dimensions, video, I.F. sound and
functional performance of
Audio/Video Stages. It give four
coloured and three
11
5
R.F. OSCILLATOR (AM/FM)
Union instrument for testing Radio and T.V. Set variable from
200 KHz to 280 MHz in seven band output modulated at 400
Hz and 1 KHz with calibrated dial. F.M. modulating
automatically switched above 50 MHz, output variable 0 to
200 m.V for the desired channel. The design is as per
C.C.I.R. standard. Workable on 220 V 50 Hz (The Pattern
same as above, with digital read
out. specification ; wave form
sin\sq \triangular frequency
Range:1Hz to 250 k Hz in five
selectable bands. Amplitude:
1to10 V P-P for
4
R.F. OSCILLATOR
T.V. PATTERN GENERATOR (BLACK AND WHITE)
L.C.R. BRIDGE
Fully Solid state instrument,
workable on 220 V 50 Hz or on 9
Volts Battery, useful for the wide
range measurement of
Resistance, Capacitance and
I n d u c t a n c e .
Resistance Range : 0.01 Ohms to 1 Meg Ohms in seven
ranges. Capacitance 2 PF to 110 MFD. Inductance 2 micro
Henries to 110 Henry in seven ranges Accuracy ±1%, D-
The Instrument generate seven
type of pattern and sound of 1 KHz.
It is ideal for T.V. Testing and
alignment of sync circuit and quick
testing of R.F. I.F. Video and sound
circuits. The equipment work on all
P O P U L A R S C I E N C E A P PA R AT U S W O R K S H O P S P V T. L T D .
3724, Opp. Kali Bari Mandir, Ambala Cantt 133001 Haryana (India)
1
ELECTRONICS
14
DUAL TRACE OSCILLOSCOPE
It is a 20 MHz Dual Channel
Oscilloscope that s ideal for,
professionals as well as
students undergoing
technical studies. It is a
rugged, light weight
instrument that features a
brijght, sharply defined trace
on a 80 by 100 mm cathode
ray tube. The internal trigger
signal
is ac coupled. An external triggering signal or an external Zaxis modulation signal can be applied via a front panel or
rear panel connector and the source selector switch. The
horizontal system provides calibration sweep speeds from
0.2s to 0.1 Micro S per division. For greater measurement
accuracy a x5 magnifier circuit extends the maximum
sweep speed to 20 ns per division. Special Features :
Synchronisation of the signals from the two channels can be
identified by a Red LED, marked as "READY", present on
the right hand side top on the front panel.
Frequency Bandwidth
Deflection Factor
Sweep Factor
15
DC - 20 MHz
5mV/div-10V x div x 5
0.2s-0.1s/div. ±5%
Specifications :
Band width
Sensitivity
Input Impedance
Square wave calibration
Triggering
amplifier or
Sweep Time Factor
Horizontal Amplifier :
Band width
Display
18
POWER OUTPUT METER
The instrument is to measure power directly across on load.
The calibration is on a analogue meter and variable load can
be selected by an band switch. The variation of load is 4, 8,
16, 32, 250, 600, 5000 ohms, range is 0-10 watts in two steps.
0 to 1 and 1 to 10 watts F.S.D., workable on 220 Volts, 50 Hz.
19
V.T.V.M.
Workable on 220 V 50 Hz
compiled in steel cabinet,
Rectangular meter 110x90mm.
Suitable for measurement of A.C.
/ D.C., Resistance 0-1000M.
Ohms in
seven ranges R.F. 0.50 Volts R.M.S. in 4 ranges.
D.C. Range : 1.5, 5, 15, 150, 500, 1500 FS-D
20
ABSORPTION WAVE METER
The instrument is to detect Radio frequency radiations. The
wave length and strength can be known by tuning on L.C.
Circuit. It consists of variable capacitor and two plugable
21
ABSORPTION WAVE METER
Same as above with six coils 100 KHz to 100 MHz.
22
TRANSISTOR TESTOR
Instrument is to test P.N.P. and N.P.N. transistors general
purpose and low power. The indicator comprises an moving
coil meter calibrated in gain or hfe. Socket provided for
connecting transistor. Workable 220 V 50 Hz.
23
DISTORTION FACTOR METER
Instrument is measure unwanted
distorted signal in an amplifier, by
feeding pure sine wave and
amplified signal passing through
filters and distorted signal
measured on meter in terms of
percentage.
The instrument consists of sine wave generator filter circuit
Vertical D.C. to 10 MHz (3db)
10mV/Cm Maximum
1 M Ohm.
2 VP-P.
Internal from vertical
external.
0.1 us/Div. 0.1s/div. ±5%.
24
Q METER
The instrument is to measure ! (Quality factor) of an inductor.
which is necessary to know when designing coils or
transformer, measuring frequency is 1 KHZ or 10 KHZ.
Measuring range is 0.1 to 100. Moving coil meter is used as
indicator. Workable 220 V 50Hz. Balancing dial is directly
DC to 1 MHz.
8x8 cm square
OSCILLOSCOPE
This instrument is for college laboratory workable on 220
Volts. A.C. Vertical bandwidth 10 HZ to 2 MHz. Cathode Ray
tube dimensions 8 cm. Sensitivity vertical 30 mV/Cm. Time
base frequency 16 Hz to 50 KHz with Lock and Fine
arrangement All controls for Focus, Intensity. X and Y shift are
on rear panel. Built in arrangement for 50 Hz output for
SIGNAL TRACER
The instrument is used to locate faults in radio receiver.
Workable on 220 Volt Hz. Probe 100 KHz to 30 MHz is
provided to detect R.F. and I.F. Signal. The audible capability
OSCILLOSCOPE
Fully Solid state workable on 220
volts 50 Hz. All supplies are
stabilized for accurate and stable
operation. Single beam with a band
width DC to 10 MHz. The accurate
triggering of time base enable clear
and stable display on screen 8x8
cm. Vertical deflection can be
selected for either A.C. or D.C.
provision or attenuation in the input
circuit, calibrated from 5 mV to
50V/cm.
16
17
25
CLAMP ON METER
Instrument is to measure alternating voltage and
current without connecting the same, measurement
is by induction effect in coil
Measuring Range : 0 - 500 V A.C.
0 - 500 Amps. A.C.
P O P U L A R S C I E N C E A P PA R AT U S W O R K S H O P S P V T. L T D .
Phone : 91-171-2600082, 2641462 (O),4006082 , +91-94160-20462 (M) Telefax : 91-171-2641462
2
ELECTRONICS
26
31
SOUND LEVEL METER
The instrument is to measure sound pressure in public
palaces, workshop, machinery mills, vehicles. The sound is
picked up and amplified attenuated and fed moving coil meter
32
27
STROBOSCOPE
HANDY DIGITAL IC/MEMORY TESTER
Digital IC Tester for testing TTL / CMOS / DRAM/ Most of the
Digital circuits use 74 series TTL, 40/45 series CMOS & 41/44
series DRAM. It is essential to test the ICs before it is put into
t h e c i r c u i t . T h i s Te s t e r i s a l s o u s e f u l f o r
s e r v i c i n g / m a i n t e n a n c e .
The IC Tester is having 24 Pin ZIF socket for testing the ICs. It
has its own display of 16x1 LCD and own menu for guiding the
user. It has the function of selecting the IC number, Auto
Search for unknown ICs, and test the ICs. Its average search
time is less than 0.8 se
33
DRAM Series
&
ZIF
Average search time
sec.
Dimension
Weight
29
34
24 Pin socket
Less than 0.8
30
35
DIGITAL MILLI VOLT/MILLI-AMP SOURCE AND METERS
(Thermo-Couple Calibrators) Provide continuously variable
voltage and current outputs. The range of current output
variable from 0-200 mA and the range of voltage output of 0200 millivolts DC. Selection of current and voltage output
available by means of a front panel control. Choice of
measurement of output source voltage. Output source
current of unknown external voltage possible by front panel
control on 3.5 digit display. Source impedance of 2 ohms for
voltage source. Input impedance of DVM more than 10 M
PHOTO ELECTRIC COLORIMETER
The instrument is unique for analytical laboratory. Operate on
220 Volts 50 Hz. Light source is from highly established
Power Supply with Sensitive Photo Voltic Cell and slow
motion shutting diaphragm. Transmittance 0-100 and optical
Density 0-2. Test Tube dia 12 mm, Eight coloured filters.
DIGITAL MULTIMETER
Hand held 9 volts battery operated. Measurement range from
0.1 millivolts to 1000 volts for DCV in 5 ranges, 0.1 millivolts to
750V AC in 5 ranges, 0.01 ohms to 20 Meg ohms in 6 ranges.
Diode testing facility. Audio buzzer for continuity 3.5 digit for
DIGITAL CONDUCTIVITY METER
The instrument is designed to read
Conductance of Solution and has
wide range of measurement .02
Micro MHo to 1 MHo and in 3.5
Digits read out Accuracy +0.5% or 1
Digit Display L.E.D. or L.C.D.
7400 to 741245
4000 to 40257 &
4501 to 4585
4164 to 414000
4464 to 441000
16x11x45 cm
0.34 kg.
DIGITAL CAPACITANCE METER
Useful for manufacturers and users of all kinds of
condensers, co-axil and multicore cables transformers,
motors and other components where measurement of
capacitance is necessary. Display the value of capacitance
directly on 4 digit display. Capacitance measurement range
from 1 pF to 10,000 microfarads in 7 full scale range.
Accuracy of measurement + 0.5% + 2 least counts. Display
reading directly without any need of balancing. Over range
indication and test leads compensation facilities available.
FEATURES :
Can test 74 Series TTL.
Can test CD 40/45 Series CMOS.
Can test 41/44 Series DRAM.
24 Pin ZIF socket for testing Ics.
SPECIFICATIONS :
TTL Series
CMOS Series
DIGITAL FREQUENCY METER
Display frequency on 6 digit
display, Range of measurement
from 1 Hz to 50 MHz. Sensitivity of
signal 20 mV r.m.s. from 10 Hz to 1
MHz, increasing to 50 mV r.m.s. as
1 MHz and 50 MHz. Input
protection to 550 V (DC + peak
AC). Resolution of 0.1 Hz
to 10 Hz and 100 Hz for gatings period of 1 seconds,
Accuracy better than ±001% 1 least count. Uses Oven
Instrument is to see the stroboscopic effect and determine the
speed of moving articals without connecting it with revolving
wheel shaft. Measuring range : 100 RPM to 10,000 RPM. with
28
A.C. MILLI VOLTMETER TYPE
Measuring Range 1 MV to 20 V AC Selectable in range 199.9,
1999 mV, 19.99VDisplay 3.5 digit. Mains operated 220V 50
36
PHOTO ELECTRIC COLORIMETER
Do with digital meter.
37
DIGITAL MAINS FREQUENCY METER
The instrument for precise sensing of Mains Frequency, has
three Digit Display, Crystal Control reference, Panel
mounting type cabinet. Power supply and all necesasary
38
DIGITAL LUX METER
L.C.D. display workable on 9 Volts Battery 3.5 Digit, precisely
calibrated in terms of LUX Power, three ranges 0-200, 2000,
20,000 LUX.
P O P U L A R S C I E N C E A P PA R AT U S W O R K S H O P S P V T. L T D .
E-mail : [email protected] Website : www.psawcatalogue.com, www.popularscientific.com
3
ELECTRONICS
39
DIGITAL PH/MV METER
48
Useful for precise and stable pH/mV measurement and ionic
activity with specific electrodes, useful for Chemical,
Pharmaceutical, Pesticide, Medical, Soil, Agriculture, Water
and Laboratories, pH measurement 0 to 14pH corresponding
mV measurement 0 to ±199.9 mV. Resolution ±0.01 pH,
Accuracy ±1% Temperature Compensation of solution also
40
DIGITAL FLUX METER (GAUSS METER)
1. 100 V Power Supply with Voltmeter and
Microamparemeter.
2. Lamp Hose for illumination of light
49
1. Photo Voltic Cell mounted
2. Lamp House for illumination of light.
3. Optical Bench Double Rod
4. Connection leads
5. Power Supply with meters.
DIGITAL L.C.R. METER
Capacity measurement 0-10,000
micro farad, Resistance upto 20M
ohms and inductance upto 2,000
Henries, D & Q value is also direct
readable. 4 Digit L.E.D. display.
APP. TO DETERMINE INVERSE SQUARE LAW IN PHOTO VOLTIC CELL
Activity :- To draw characteristics between distance and
intensity of light. The apparatus consists of :
Workable on 220 Volt 50 Hz. Measuring range upto 2K/20K
gausses. Direct reading calibrated in terms of gausses, 3.5
digits display. Complete with Hall probe. Accuracy ±0.5%
41
PHOTO CELL CHARACTERS
Object :- To draw V & I characteristics of Photo (gas Filled)
Contents :-
50
APP. TO DRAW SPECTRAL, AZIMUTHAL ANGLE & STOPPING
POTENTIAL OF GIVEN PHOTO VOLTIC CELL
The apparatus consists of :42
DIGIAL L.C.R. METER HAND HELD
1. Photo voltic cell mounted
2. Micrometer slit with mounting
3. Light source with coloured glass fiters
4. Optical Bench Double Rod
5. Low voltage D.C. source for stopping potential
Hand held L.C.D. display instrument with wide range of
measurement. Inductor 1 mH to 100H, capacity 1 pF to 100
mF Resistance .1 ohms to 20 meg ohms.
43
DIGITAL POTENTIOMETER
A digital instrument with precise potentiometeric
measurement of ionic solution. Measuring range 0-200 milli
43
44
51
DIGITAL R.P.M. METER
Non contact type with digital readout workable on 9V Battery
L.C.D. display. Complete with senser and working manual.
52
45
G.M. COUNTER DIGITAL
Instrument consists of
power supply for G.M. Tube
with digital read out meter. 6
Digit counting system with
its power supply. Controls
for reset, start and stop
through on panel. One
46
53
LED CHARACTERISTICS APPARATUS
To study V-I Characteristics of a LED.Instrument consists of
DC Regulated Power Supply 0-3 VDC/25mA, two round
meters for voltage & current measurement, LED mounted on
the panel, connections of Supplies & LED brought on
PHOTO CELL MOUNTED ON BASE
54
PLANK'S CONSTANT APPARATUS
CHARACTERISTICS OF OPTO ELECTRONIC DEVICES
To study VI Characteristics of Photo Transistor, Photo Diode
& LED. Instrument consists of DC Regulated Power Supply 03 VDC/150mA, two round meters for voltage & current
measurement, Photo Transistor, Photo Diode & LED
mounted on the panel, connections of Supplies, Meters &
Components brought on terminals with light source.
Activity : To determine stopping potential h in Photo Cell
(Vacum Type) The apparatus consists of :
1. A vacuum type photo cell mounted in housing, along with
three coloured glass filters.
2. Lamp house for monocrometic light
3. Optical Bench Double Rod
4. Low voltage D.C. source with moving coil meters
PHOTOELECTRIC RELAY APPARATUS
To study the operation LDR by relay. Instrument comprises
one Relay, LDR mounted on front panel, Lamp holder with
10W Bulb mounted with power supply. The effect of relay is
demonstrated by bulbs.
Dimension 8"x6"x5".
Valve version Photo Cell (VACUM TYPE) fitted in housing.
Useful for PLANK'S CONSTANTAPPARATUS.
47
LDR CHARACTERISTICS APPARATUS
To plot a graph, Current versus Intensity of Light at different
value of voltages. Instrument comprises of DC Regulated
Power Supply 0-3 VDC/100mA, two round meters for voltage
& current measurement, LDR mounted on the panel,
connections of Supplies & LDR brought on terminals with light
55
PHOTODIODE CHARACTERISTICS APPARATUS
To plot a current versus Intensity of light at different value of
voltages. Instrument consists of DC Regulated Power Supply
0-10 VDC/50mA, two round meters for voltage & current
measurement, Photo diode mounted on the panel,
connections of supplies & photodiode brought out at
t e r m i n a l s
w i t h
l i g h t
s o u r c
P O P U L A R S C I E N C E A P PA R AT U S W O R K S H O P S P V T. L T D .
3724, Opp. Kali Bari Mandir, Ambala Cantt 133001 Haryana (India)
4
ELECTRONICS
56
PHOTO TRANSISTOR CHARACTERISTICS APPARATUS
2.
Power supply, for cathode voltage to CRT. Provided with
high resistance voltmeter, Also having solenoid supply
with coarse and fine control arrangement, an ampare
meter is used to measure current passing in solenoid.
3. Cathode Ray Tube mounted to moveable inner side of
To plot a graph, current versus Intensity of light at different
value of voltages. Instrument comprises of DC Power Supply
0-10VDC/50mA, two meters for voltage & current
measurement, Photo Transistor mounted on the panel,
connections of supplies & photo transistor brought on
64
57
MERCURY VAPOUR LAMP (HG) FOR USE WITH ABOVE PHOTO VOLTAIC CELL
A Mercury (Hg) Vapour Lamp 80 Watt with choke is fitted
inside wooden box and wooden box is provided with slit,
useful for above apparatus
58
SOLAR CELL MOUNTED
Solar cell mounted.
59
SOLAR CELL CHARACTERISTICS APPARATUS
Activity : To draw V & I characteristics of a solar cell.
The apparatus consists of :
1. Moving coil meters fitted on panel with power supply
2. Lamp house with power supply
3. Solar cell mounted
4. Optical Bench Double Rod
65
60
PLANK'S CONSTANT APPARATUS USING SOLAR CELLACTIVITY :
TO DETERMINE THE STOPPING POTENTIAL BY USING SOLAR CELL.
The apparatus consists of :
1. Low voltage D.C. power supply with voltmeter and micro
ampere meter
2. Lamp house for illumination of light
3. Solar cell mounted
4. Optical Bench Double Rod
5. Connection leads
61
62
63
66
E/M BY HELICAL METHOD (SOLENOID METHOD)
1. Standard Solenoid of multi-turned layers fitted on
wooden
E/M BY SHORT SOLENOID METHOD (MEGNETRON METHOD)
To study charge of an electron by
short solenoid method. Kit
consists of Low voltage DC
Power Supply with filament
voltage, variable High
voltage and Solenoid current source. Two meters are
provided for Anode Voltage and solenoid current. One
E/M BY THOMSON (BAR MAGNET METHOD)
Having three major parts to
measure electron for e/m by
Helical Method, i.e.
POWER SUPPLY FOR MILLIKAN'S OIL DROP APP.
Specially designed for use with Millikan's Oil Drop Apparatus.
It give IC regulated D.C. output 0.300 volt continuously
variable to be applied to condenser plates and a 6 volt at 3A
A.C. supply for the lamp house.
PHOTO MULTIPLIER TUBE 931 WITH HOUSING
Activity : To measure e/m of
Electron by Thomson
Method Bar Magnet
method. One method
of demonstration
modern
physics in the controlled bending of stream of high speed
electrons in a magnetic field. The actual measurement by
students of the ratio of the charge on the electron to its
equally minute mass imparts a stimulating sense of
achievement. e/m apparatus has been perfected to the point
where it is possible for this fundamentally important
measurement to be carried out with good accuracy. Power
Supply : E.H.T. 800V D.C. for cathode Voltage to C.R. tube.
0-100 volts D.C. with moving coil meters to measure the
Deflecting voltage either y1 or y2 Plates.
Cathode Ray tube fitted on wooden frame with scale divided
MILLIKAN'S OIL DROP APPARATUS
The noted oil drop experment by which Prof.
Robert A. Millikan measured the charge on
the
electron can be repeated by the student
with this equipment. The latest improved
design
is based upon the experience and
recommendation of teachers.
Principal elements of the
assembly are specially designed
condenser, a light source and a
measuring microscope. The All are
mounted on a
common support. Consisting of a heavy cast iron base which
is mounted on a steel pillar that carries the microscope and
the lamp house. The microscope can be adjustedsmoothly
by slow motion screws in the horizontal as well as in the
67
E/M BY MAGNETIC FOCUSING METHOD
To study charge of an electron by using Magnetic Focusing
method. Kit comprises of High voltage Power Supply with
intensity, focus X, Y deflection & Solenoid current controls.
Two meters provided for acceleration voltage & for solenoid
current controls. One 3" CRT mounted on Teak Wood Stand
68
MICROPROCESSOR TRAINING KIT
Kit is based on 8085 Microprocessor and is designed to
provide ease in interaction with 8 bit Microprocessor
c
a
p
a
b
i
l
i
t
i
e
s
.
This Kit can be used to train engineers about the
Microprocessor Technology, to control any Industrial process
and to develop Software for 8085 system.
This Kit has a powerful monitor in 4/8 bytes EPROM. The
monitor can be extended to incorporate an Assembler and
Dissembler for 8085.
The Input/Output structure includes programmable 241/O
lines. It has got 16 bit programmable Timber/Counter using
8253 for generation of any type of counting. Different types of
INTERFACING MODULES from us can be hooked with this
kit to perform simple experiments & projects in the lab. These
P O P U L A R S C I E N C E A P PA R AT U S W O R K S H O P S P V T. L T D .
Phone : 91-171-2600082, 2641462 (O),4006082 , +91-94160-20462 (M) Telefax : 91-171-2641462
5
ELECTRONICS
69
DIODE VALVE CHARACTERISTICS APPARATUS (POWER SUPPLY
78
VI Characteristics of Diode Valve. Instrument consists of DC
Regulated Power Supply 0-300VDC/30ma, 6.3V AC/1Amp,
two meter for voltage & current measurement, valve diagram
Printed, connections of Supplies & Valve brought on
70
71
SAME SET ABOVE, FOR WORK FUNCTION OF DIODE WITH
CIRCUIT DIAGRAM AND THREE METERS.
72
79
80
81
82
83
Calculation of 'H' Parameters, such as current gain, input
impedance, output impedance. Instrument consist of Two DC
Regulated Power Supplies 0-10VDC, 500mA/50mA 0-1V DC
at 30mA, Four meter, One PNP Transistor mounted,
connections of Supplies, Meters & Transistor are on terminals
PN JUNCTION/ZENER DIODE CHARACTERISTICS APPARATUS
(FORWARD & REVERSE V-I CHARACTERISTICS) PSAW -B3A
To study Forward & Reverse Characteristic of PN Junction
Diode & Zener Diode. Instrument comprises of two DC Power
Supplies, two meters double range to measure voltages &
current, PN Junction Diode & Zener Diode mounted &
75 V R TUBE CHARACTERISTICS
76 'H' PARAMETERS OF PNP TRANSISTOR IN COMMON EMITTER MODE
ZENER DIODE CHARACTERISTICS APPARATUS (FORWARD &
REVERSE V-I CHARACTERISTICS)
To study Forward & Reverse V-I Characteristics of Zener
Diode. Instrument comprises of DC Regulated Power Supply
0-25 VDC 15mA, two meters for voltage & current
measurement, Zener Diodes mounted on panel, connections
74 THYRATRON VALVE CHARACTERISTICS APPARATUS
To draw VI Characteristics of Thyratron valve at various Grid
Voltage Instrument comprises of Two DC Regulated Power
Supplies 10V 300 uA and 0-25 VDC /250mA, valve diagram is
Printed on Front panel, connections of Supplies & Valve
brought on terminals.
VOLTAGE STABILIZATION CHARACTERISTICS OF ZENER DIODE
To study Input Voltage, Output Voltage Char. & Output
Voltage, Load Characteristics. Instrument consists of DC
Power Supply, two round meters to measure input voltage &
output voltage, one Zener Diode mounted on panel &
connections brought out at terminals.
Dimension 10"x8"x4".
73 IONIZATION POTENTIAL OF MERCURY
To draw V-I Characteristcs of Thyratron valve and to drive
Ionization Potential of DC Power Supply 0-3 VDC/50mA & AC
6.3V 0 to 25V 500mA, two meters for voltage & current
measurement, valve diagram is Printed on Front panel,
connections of Supplies & Valve brought terminals.
SEMICONDUCTOR DIODE/PN JUNCTION DIODE CHAR. APPARATUS
To study Forward & Reverse Characteristics of PN Junction
Diode.Instrument comprises of Two DC Power Supplies 050V 2mA, 0 to 1V 200 mA two meters for voltage & current
measurement, PN Junction Diodes mounted connections of
Supplies, Meters & Diodes brought on terminals.
TETRODE/PENTODE VALVE CHARACTERISTICS APPARATUS WITH
STABELISED POWER SUPPLY
Plate & Screen Characteristics of Tetrode & Pentode Valve.
Two Power supply variable 0-300V 50 mA & 25 VDC/25
mA, AC 6.3 VAC/1Amp, five round meters for voltage &
current measurement, connections of Supplies & Valve
brought on terminals.
Valve 6SJ7
FET CHARACTERISTICS APPARATUS
To plot static & Transfer Characteristics. Instrument consist of
Two DC Regulated Power Supplies 0-10V DC/ 10mA &0-5
VDC, three meters for voltage & current measurement, FET
BFW10 mounted on the panel, connections of Supplies,
Meters & FET brought on terminals.
TRIODE VALVE CHARACTERISTICS APPARATUS WITH STABILIZED
POWER SUPPLY
VI Characteristics of Triode Valve various Grid voltages.
Instrument comprises of DC Regulated Power Supply
(PSAW -3) 0-300VDC/30mA & 0-25 VDAAC 6.3 VAC /1Amp.
three round meters for voltage & current measurement. Valve
ECC82
SCR CHARACTERISTICS APPARATUS
To plot Anode current Vs Anode Cathode Voltage
Characteristics. Instrument consist of Two DC Regulated
Power Supplies 0-3VDC/50mA & 0-150V DC, three meters
for voltage & current measurement, SCR mounted on panel,
connections of supplies. Meters & SCR brought on terminals.
84
ENERGY BAND GAP OF PN JUNCTION DIODE
To plot reverse saturation current Vs Temperature in reverse
biased PN junction Diode. Instrument consists of DC
Regulated Power Supply 0-IV DC/500 mA, two round meters
for voltage & current measurement, one PN Junction Diode is
in Oven, 100ºC thermometer provided with temperature
77 TRANSISTOR CHARACTERISTICS APPARATUS
Input & Output Characteristics of
Common Base PNP & NPN
Transistors Input & Output
Characteristics of Common
Emitter PNP & NPN Transistors.
Instrument consist of Two DC
Regulated Power Supplies 010VDC/500 mA/ 50 mA & 0-1 VDC/30 mA, four round meters
for voltage & current measurement, one PNP & one NPN
Transistor mounted behind the panel, connections of
Supplies & Transistors brought out on terminals.
85
THERMISTOR CHARACTERISTICS APPARATUS
To plot -ve Resistance co-efficient Characteristics of a
Thermistor. Instrument comprises of DC Regulated Power
Supply 0-IV-DC/1 mA, two meters for voltage & current
measurement, one Thermistor and a Oven. Connections of
Supplies, Meters & Thermistor brought on terminals provided
P O P U L A R S C I E N C E A P PA R AT U S W O R K S H O P S P V T. L T D .
E-mail : [email protected] Website : www.psawcatalogue.com, www.popularscientific.com
6
ELECTRONICS
86
UJT CHARACTERISTICS APPARATUS
93 CHARACTERISTICS & APPLICATIONS THYRISTORS
To plot V-I Characteristics & to measure interbase resistance.
Instrument comprises of Two DC Regulated Power Supplies
0-10V, DC/30 mA & 0-IV, three round meters for voltage &
current measurement, one UJT 2N2646 mounted on panel,
connections of Supplies, Meters & UJT brought on terminals.
87
RESISTIVITY OF SEMICONDUCTORS BY FOUR PROBE METHOD AT
DIFFERENT TEMPERATURES AND DETERMINATION OF BAND-GAP
The experiment consists of the
following :
(i) Four Probe Arrangement
(ii) Oven (upto 200ºC)
(iii) Sample : Ge Crystal
mounted
(iv) Thermometer (0-200ºC)
(v)Four Probe Setup
(a) Constant Current power
supply digital Accuracy : +0.25%
of the
reading +1 digit Load Regulation : 0.03% for no load to full
load
(b)Electronic Millivoltmeter 200 mV Accuracy : + 0.1% of
To study Characteristics & Applications of Diac, Triac, UJT &
SCR. Instrument comprises of Three DC Regulated Power
Supplies 0-15 VDC/150mA, 0-50 VDC/100 mA & 0-2.5V
DC/200 mA, four dual range meters for voltage & current
measurement, UJT, SCR, Diac, Triac & their supportive
components mounted on panel, connections of Supplies,
94
DIAC CHARACTERISTICS APPARATUS
To study VI Characteristics of Diac. Instruement comprises of
DC Regulated Power Supply 0-50 VDC/100mA, two round
meters for voltage & current measurement, one Diac
mounted on panel, connections of Supplies & diac brought at
95 TRIAC CHARACTERISTICS APPARATUS
To study the MT Characteristics with Gate Signal. Instrument
comprises of Two DC Regulated Power Supplies 025VDC/100mA & 0-5 VDC/200 mA, three round meters for
voltage & current measurement, Triac mounted on panel,
connections of Supplies & Triac brought on terminals.
96 WAVE LENGTH OF LIGHT OF LASER
88
SUSCEPTIBILITY OR FE CL3 SOLUTION
To study different pattern of laser light and determine its wave
length. Complete apparatus with Laser Source 5 Milli Watts
with Power Supply opreatable 220V 50Hz, Optical Bench and
Riders, Set of 13 experiment Kit, Laser fitted with beam
expander. Single Slit, Coarse Grating, Multiple Slip, Single
Taper Slit, Holes A, B, C, D, Gray Filter, Multiple slit, Circular
To study susceptibility of Ferous Solution in strong magnetic
field, complete apparatus consisting of electromagnet of 7.5
K.G. strength with its Power Supply 0-100V variable 4 Amps.
Digital Gauss Meter 0-20 Kg with Hall Probe., Graduated
89
HALL EFFECT EXPERIMENT
The set up consists of Electromagnet of 7-5 K.G., Power
Supply for Electromagnet 0-100V, 4 Amps with meter,
Germanium Crystal mounted and its constant current power
supply 0-20mA fitted with two Digital Meters for Halls Voltage
90
VERIFICATION OF VARIOUS LAWS & CONVERTION OF SIGNAL
97
Instrument consists of Sine Wave generator, Step Down
Transformer, Circuit Diagram for Peak & average Value
measurement Printed and connections brought on terminals.
ULTRASONIC DIFFRACTION GRATING EXPERIMENT
To d e t e r m i n e v e l o c i t y o f u l t r a s o n i c w a v e )
Complete apparatus with R.F. Oscillator 3-8 Mhz, Crystal with
tank, Specto meter of 9" bed, Sodium Lamp with Wooden Box
and Transformer.
98
To calculate dielectric constant of liquids and solids. The
instrument consists of high frequency oscillator of tuneable
with outer gang condenser optimum tunning is indicated on
meter. The change after placing dielectric between parallel
99
OHM'S LAW APPARATUS
To verify Ohm's law i.e. V = IR
Instrument consists of Two moving coil meters to measure
voltage & current, One wire wound Potentiometer, Circuit
diagram Printed Connections brought on terminals for
connecting 6 Volts battery & One wire wound Resistance and
MOSFET CHARACTERISTICS APPARATUS
To plot VDS VSID for different values of VGS. Instrument
comprises of Two DC Power Supplies 0-10V, DC 10mA & 05V DC, three meters for voltage & current measurement, one
Mosfet no. TRF 840 mounted on panel, connections of
RESISTANCES IN SERIES & PARALLEL APPARATUS
To verify properties of Resistances when connected in series
& parallel. Instrument comprises of Two moving coil meters to
measure voltage & current, circuit diagram for series &
parallel connections Printed, Resistance mounted along
91 DIELECTRIC CONSTANT APPARATUS
92
MEASUREMENT OF PEAK, AVERAGE & RMS VALUE OF A AC SIGNAL
100 CHARGING & DISCHARGING OF CONDENSOR
To study RC time constant using various sets of Resistance &
Capacitors. Instrument comprises of DC Power Supply with
selector switch to select different voltages, One
Microammeter, Circuit diagram is Printed, Terminals are
provided for connecting different values of Reistance &
P O P U L A R S C I E N C E A P PA R AT U S W O R K S H O P S P V T. L T D .
3724, Opp. Kali Bari Mandir, Ambala Cantt 133001 Haryana (India)
7
ELECTRONICS
101 FLASHING & QUENCHING OF NEON APPARATUS
To Calculate Charge & Discharge time of a Condensor.
Instrument consists of High voltage DC Power Supply
100VDC/30 mA, 3 Capacitors (Paper Type) connected can
be selected using toggle switches & One Neon lamp.
VERIFICATION OF NETWORK THEOREMS
109 VERIFICATION OF NETWORK THEOREMS
To verify Superposition, Norton's Thevinin's & Maximum
Power Transfer Theorems. Instrument comprises of 3 Fixed
output DC Power Supplies of 12V & 5V at 100 mA current, 4
moving coil meters, Circuit diagram for all the 4 Theorems
Printed on the front panel & connections of Supplies, Meters,
Resistances & Potentiometers brought on Terminals.
102 BH CURVE APPARATUS (WITH DIFFERENT METERIAL
To trace Hystersis curves. Instrument comprises of AC Power
Supply 3-15 VAC, Output selectable using band switch,
Circuit daigram for BH Curve Printed, Components
connected panel, provision for connecting external
Inductance, Input & Output Connections brought on terminal.
110 VERIFICATION OF SUPERPOSITION THEOREM
Instrument consists of Two Fixed output DC Regulated
Power Supplies of 12V & 5V at 500 mA current, Three moving
coil meters, Circuit diagram Printed on the front panel &
103 CONVERTION OF GALVANOMETER INTO A VOLTMETER AND CURRENT METER
Instrument comprises of DC Regulated Power Supply 0-10
VDC/500 mA, two round meters (One Voltmeter & One
Galvanometer), Three set of Resistances mounted on panel,
connections of Supplies, Meters & Resistances brought on
104 LCR RESONANCE APPARATUS (SERIES & PARALLEL)
111 VERIFICATION OF NORTON'S THEOREM
Instrument consists of One Fixed output DC Power Supply of
12V at 250 mA current, Two moving coil meters, Circuit
diagram Printed on the front panel & connections of Supplies,
112 VERIFICATION OF THEVININ'S THEOREM
To plot Frequency Vs Current Characteristics of LCR circuit,
connection in series parallel. Instrument comprises of 1
Resistance, 1 Capacitors, & 1 Insductance connected &
connections brought out at Terminals. 2 AC moving coil
meters to measure voltage & current with Audio Frequency
Instrument comprises of One Fixed output DC Power Supply
of 12V at 250 mA current, Two moving coil meters, Circuit
diagram Printed on the front panel & connections of Supplies,
113 VERIFICATION OF NORTON'S & THEVININ'S THEOREMS
105 LCR IMPEDANCE CIRCUIT
To calculate AC power factor of LCR circuit when connected
in series on AC voltage. Instrument comprises of AC Power
Supply100 V, selectable using bandswitch, 2 AC moving coil
meter to measure voltage & current, 1 Resistances, 1
Capacitors & 1 Inductance connected & connections brought
114 VERIFICATION OF RECIPROCITY THEOREM
Instrument comprises of One Fixed output DC Power Supply
of 12V at 300 mA current, Two moving coil meters, Circuit
diagram Printed on the fornt panel & connections of Supplies,
115 VERIFICATION OF MAXIMUM POWER TRANSFER THEOREM IN DC CIRCUITS
106 RC CIRCUIT (TRANSIENT RESPONSE)
Instrument comprises of One Fixed output DC Power Supply
of 12V at 300 mA current, Two moving coil meters, Circuit
diagram Printed on the front panel & connections of Supplies,
Meters, Potentiometer & Resistances brought at terminals.
To study RC circuit as Low Pass & High Pass Filters. Circuit
diagram for low Pass, High Pass Filter Printed, Three
Resistances, Three capacitors are provided and connections
brought out on terminals.
107 CLIPPING & CLAMPING CIRCUIT APPARATUS
DEMONSTRATION MODELS
116 DEMONSTRATION MODEL FOR EXPERIMENTS OF MW RADIO CIRCUITS
To study effect of Positive & Negative Clipping & Clamping on
Sine Wave. Two fix Output DC Power Supplies connected in
series of Diodes for Positive & Negative Clipping, Circuit
diagram for Clipping & Clamping Printed, Components
placed inside & connections brought at terminal. Dimension
To study working & various faults of MW Transistor Receiver
and Signal/noise and output. The until complied on Phenolic
sheet with top side nicely screen printed & circuit diagram
drawn. Components are soldered along the circuit important
connection are brought out on terminals. Instrument consists
of Power Supply, AGC section, IF section, Oscillator section,
Antenna section & output section. Also provided with 6 VDC
108 HALF WAVE/FULL WAVE & BRIDGE RECTIFIER APPARATUS
To study Efficiency & Ripple factor in case of Half wave, Full
wave & Bridge rectifier on load & study filters.
Instrument comprises of AC Power Supply, 2 meters to
measure Output Voltage & current, Junction Diodes, Filter
Circuit kit, load Resistances selectable using toggle switches
& all important connections on terminals. Dimension
117
DEMONSTRATION MODEL OF TRANSISTOR CASSETTE PLAYER/RECORDER
TRAINER KIT (TWO IN ONE)
To study working & various faults of MW Transistor receiver,
To study working & various faults of Cassette Player and To
Study working & various faults of Tape Recorder.
The whole unit is made up on Phenolic sheet with top side
nicely screen printed & reverse side is Printed circuit layout
(PCB). Components are mounted on PCB tags for easy
replacement/Fault creation. Acrylic Cover is provided at the
top to protect the instrument.
D1 Demonstration Televison (Black & white)
D2Demonstration Coloured Television
P O P U L A R S C I E N C E A P PA R AT U S W O R K S H O P S P V T. L T D .
Phone : 91-171-2600082, 2641462 (O),4006082 , +91-94160-20462 (M) Telefax : 91-171-2641462
8
ELECTRONICS
118
119
LINEAR I.C. TRAINER
STUDY OF TRANSISTOR AMPLIFIER CIRCUITS
To study Frequency Response, Input Impedance, Output
Impedance & -ve Feed Back of Common Base, Common
Emitter & Common Collector Transistor Amplifiers.
Instrument components mounted on the front panel &
important points brought on terminals OPT Audio Frequency
126 STUDY OPERATIONAL AMPLIFIER AS ADDER, SUBTRACTOR,
INTEGRATOR AND DIFFERENTIATOR
Instrument comprises of 2 DC Regulated Power Supplies of
0-5 VDC, Power Supply ±15VDC, 2 Dual range, round
meters to measure input and output voltages & Combination
of Resistances, Capacitors mounted on Front Panel.
OPT. Audio Frequency Function Generator PSAW -93, CRO
PSAW -96.
STUDY THE EFFECT OF NEGATIVE FEED BACK OF TRANSISTOR AMPLIFIER
(i) Voltage gain
(ii) Input Resistance
(iii) Output Impedance
120 FET COMMON SOURCE AMPLIFIER
Study of Voltage Gain and Frequency Response of a
Common Source Amplifier. Instrument comprises of DC
Regulated Power Supply, Circuit diagram is printed,
Components mounted on the front panel & connections of
important points brought on terminals. OPT Audio Frequency
127 STUDY OF OPERATIONAL AMPLIFIER AS DIFFERENTIATOR & INTEGRATOR
128 STUDY OF OPERATIONAL AMPLIFIER AS SCHMITT TRIGGER
129 STUDY OF OPERATIONAL AMPLIFIER AS SINE TO SQUARE WAVE CONVERTER
STUDY OF OPERATIONAL AMPLIFIER AS SQUARE TO TRIANGULAR &
TRINAGULAR TO SQUARE WAVE CONVERTOR.
130
STUDY OF OPERATIONAL AMPLIFIER AS CLIPPING AND CLAMPING CIRCUIT
121 BIASING OF TRANSISTOR (BJT)
To Study of different Biasing Circuit for Transistor such as
Fixed Bias Method, Collector to Base Bias, Emitter Resistor
Bias and Voltage Divider Bias Methods. Instrument consists
of One DC Regulated Power Supply, One NPN Transistor, 2
meters to measure the voltage and current, Different types of
Resistances connected inside & connections brought on
terminal. Dimension 8"x6"x4".
122 R.C. COUPLED AMPLIFIER (TWO STAGE)
Study of voltage gain & frequency response of a R.C.
Coupled Transistor Amplifer Opt. Function Generator PSAW
CHARACTERISTICS OPERATIONAL AMPLIFIERS
123 OPERATIONAL AMPLIFIER AS INVERTING & NON INVERTING AMPLIFIER
To study Operational Amplifier as Inverting & Non Inverting
Amplifier. Insturment comprises of DC Power Supplies of 500
mA & ±15V DC, circuit diagram Printed & different
Resistances can be connected externally for various
observations. Dimension 10"x7"x3". Digital Multimeter 3.5
124 STUDY OF OPERATIONAL AMPLIFIER
To study operational Amplifier as Inverting, (a) Unity gain
buffer stage (b) Non-Inverting Amplifier (c) Inverting Amplifier
(d) Summing Amplifier (e) Difference Amplifier Instrument
comprises of 3 DC Regulated Power Supplies of 0 to ±15V
and 0 to 6V.
125 STUDY OF CHARACTERISTICS OF OPERATIONAL AMPLIFIER
To study the basic characteristics of OP-Amp as Input Offset
Current, Offset Voltage, Slew Rate, Band Width and Null
Balancing.
Instrument comprises of ±15 VDC Regulated Power Supply,
2 round meters, Different type of Resistance and Capacitors,
IC 741 connected inside & connectiions brought out at 4mm
Sockets.
OPT. DMM, Audio Frequency Function Generator PSAW-93
131 STUDY OF OPERATIONAL AMPLIFIER AS VOLTAGE COMPARATOR
Instrument consists of + 15 VDC Regulated Power Supply, 1
meter, Combination of Resistances, Zener Diode & IC 741
132 STUDY OF OPERATIONAL AMPLIFIER AS V TO I TO I TO V CONVERTOR
Instrument comprises of + 15 VDC Regulated Power Supply,
2 round meters, combination of Resistances & IC 741
Connected inside & connections brought out at sockets on
133 STUDY OF OPERATIONAL AMPLIFIER AS VOLTAGE AND CURRENT FEED BACK AMPLIFIER
To study the operational amplifier application as voltage and
c u r r e n t f e e d b a c k a m p l i f i e r .
Instrument comprises of +15VDC Regulated Power Supply, 2
round meters of Dual range, combination of Resistances & IC
741 connected inside & connections brought out at sockets
on front panel.
134 STUDY OF INSTRUMENTATION AMPLIFIER
Calculate the Voltage Gain of Instrumentation Amplifier and
draw a curve between V & R. Instrument comprises of One
+15VDC Regulated Power Supply, 2 DC Regulated short
circuit and overload protected continuously variable Power
Supplies, 3 no. IC 741 placed inside & connections brought
out at sockets. One Potentiometer and combination of
135 STUDY OF LOGRITHEMIC AMPLIFIER
To study the Log. Antilog and Ideality factor for Log Amplifier
and plot a graph of V1-V0 for Antilog Amplifier.
Instrument comprises of DC Regulated short circuit and
overload protected continuously variable Power Supply,
±15VDC, one Potentiometer, IC 741 and Diode 4007/OA 79.
STUDY OF MULTIVIBRATORS
All the Multivibrators Kits are with DC Power Supply,
Circuit Diagram Printed & Components mounted on front Panel.
Kits require CRO as Accessories.
136 MONOSTABLE MULTIVIBRATOR USING IC 555
P O P U L A R S C I E N C E A P PA R AT U S W O R K S H O P S P V T. L T D .
E-mail : [email protected] Website : www.psawcatalogue.com, www.popularscientific.com
9
ELECTRONICS
137 MONOSTABLE MULTIVIBRATOR USING TRANSISTORS.
150
VERIFICATION OF LOGIC GATES & DEMORGAN'S THEOREMS USING TTL LOGIC GATES
3 input AND gate, NAND gate, NOR gate, 2 input EX_OR
gate, single input NOT gates.
Instrument comprises of DC Regulated Power Supply
Gages, IC's placed inside the cabinet & connections brought
at sockets. 4 SPDT swtiches provided for selecting logic '1' &
gates, NOR gate, NAND gate & Demorgan's Theorems can
151
VERIFICATION OF TRUTH TABLES OF LOGIC GATES USING NAND GATE
138 ASTABLE MULTIVIBRATOR USING IC 555
139 ASTABLE MULTIVIBRATOR USING TRANSISTORS
140 BISTABLE MULTIVIBRATOR USING IC 555
141 BISTABLE MULTIVIBRATOR USING TRANSISTORS
To verify the truth table of AND
gate, OR gate, NAND gate, NOR
gate & NOT gate using NAND.
Instrument comprises of Power
Supply 2 Red LED output
indicators, circuit diagram printed
for 4 'NAND', and gates & their
respective IC's placed inside the
142 MONOSTABLE & FREE RUNNING MULTIVIBRATORS USING IC 555
143 MONOSTABLE & FREE RUNNING MULTI VIBRATORS USING TRANSISTORS
OSCILLATORS
144 HARTLEY OSCILLATOR
To study the Frequency generated by a Hartley Oscillator
Instrument comprises of DC Regulated Power Supply, Circuit
diagram Printed & components mounted on panel.
F65 STUDY OF 4 BIT ADDER AND SUB-TRACTOR
To study the 4 Bit Adder and Sub-tractor using IC 7483.
Instrument comprises of DC Regulated Power Supply
5V/150mA, 4 Logic inputs selectable using SPDT switches, 4
output LED indicators, circuit diagram Printed & connections
brought out at sockets on the front panel.
145 COLPITT OSCILLATOR
To study the Frequency and Wave shape generated by a
Colpitt Oscillator. Instrument comprises of DC Power Supply,
Circuit diagram Printed & components mounted on front
F65A DIGITAL TRAINER KIT TO VERIFY ADDERS & SUB-TRACTORS USING OR, EX-OR,
AND & NOT GATES
To verify the truth table of Digital
Half Adder, Half Sub-tractor, Full
Adder & Full Sub-tractor using
OR, AND, EX-OR & NOT gates.
Instrument comprises of Power
Supply 5V for logic inputs, 4
switches for selecting logic '1' &
logic '0', 2 LED output indicators,
circuit
diagram printed for 1 two input 'OR' gate, 2 two input 'AND'
gates, 2 'NOT' gates & 2 EX-OR gates &
146 PHASE SHIFT OSCILLATOR
To study the Frequency and Wave shape generated by a
Phase Shift Oscillator. Instrument comprises of DC Power
Supply, Circuit diagram Printed & components mounted on
f r o n t
p a n e l .
147 WEIN BRIDGE OSCILLATOR USING OPERATIONAL AMPLIFIER IC 741
To study the Frequency and Waveshape generated by a
Wein Oscillator. Instrument comprises of DC Power Supply,
Circuit diagram Printed & components mounted on front
F65B DIGITAL TRAINER TO VERIFY HALF ADDER USING OR, EX-OR & AND GATES
148 LOGIC GATES EXPERIMENT
To verify the truth table for TTL
AND, OR, NOT, NAND, NOR.
Instrument comprises of 5V
Power Supply for logic '1' & logic
'0'. TTL IC's for 'AND', 'OR', 'NOT'
gates & Components soldered on
the front panel & connections
brought out at sockets.
149 VERIFICATION OF BOOLEON IDENTITIES & DEMORGAN'S THEOREMS
To verify the truth table of 3 input AND gate, NAND gate, NOR
gate, single input NOT gates, Booleon expressions &
Demorgan's Theorems.
Instrument comprises of DC Power Supply, 4 swtiches for
selecting logic '1' & logic '0', 2 Red LED output indicators,
circuit diagram printed for 5 'OR', 5 'AND' & 4 'NOT' gaes &
F65C DIGITAL TRAINER TO VERIFY HALF SUB-TRACTOR USING OR, EX-OR & AND GATES
F65D DIGITAL TRAINER TO VERIFY FULL ADDER USING OR, EX-OR & AND GATES
F65E DIGITAL TRAINER TO VERIFY FULL SUB-TRACTOR USING OR, EX-OR & AND GATES
F62 DIGITAL TRAINER TO VERIFY ADDERS & SUB-TRACTOR USING NAND GATES
To verify the truth table of Digital Half Adder, Half Sub-tractor,
Full Adder & Full Sub-tractor using NAND gates.
F52A STUDY OF 4 BIT BINARY TO GRAY CODE CONVERTOR
Instrument comprises of DC Regulated Power Supply
5/VDC/150mA, 4 Logic inputs selectable using SPDT
switches, 4 output LED indicators, circuit diagram Printed,
IC's placed inside & connections brought out at sockets on
F45 STUDY OF 4 BIT RIPPLE COUNTER (FORWARD & REVERSE)
To Verify Truth tables of 4 Bit Forward & Reverse Counters
using 4 JK Flip Flops. Instrument consists of Power Supply, 1
Hz monoshot clock pulse, Two output indicators, Circuit
diagram for 4 'JK' flip-flops Printed & connections for inputs &
P O P U L A R S C I E N C E A P PA R AT U S W O R K S H O P S P V T. L T D .
3724, Opp. Kali Bari Mandir, Ambala Cantt 133001 Haryana (India)
10
ELECTRONICS
F48 STUDY OF 4 BIT BCD COUNTER/DECIMAL TO BINARY ENCODER USING IC 7490
F43B DIGITAL TRAINER TO STUDY 'RS' TYPE, 'JK' & 'T' TYPE FLIP-FLOP
Instrument comprises of DC Regulated Power Supply 1 Hz
clock pulse, four output indicators, Circuit diagram for IC 7490
Printed & connections for various inputs & outputs brought
out at the sockets on the front panel.
To study & verify Truth tables of 'RS', 'D' Type, 'T' Type & 'JK'
f l i p f l o p s u s i n g N A N D g a t e s .
Instrument comprises of DC Power Supply, 4 logic inputs,
logic '1' & logic '0' selectable using switches, 1 Hz clock pulse,
Two output indicators, Circuit diagram for 'RS' & 'JK' flip-flows
Printed & connections for inputs & outputs brought out on the
F48A STUDY OF 4 BIT BCD COUNTER/DECIMAL TO BINARY ENCODER USING NAND GATES
To convert Decimal input to Binary output using NAND gates.
Instrument comprises of Power Supply 10 logic inputs
selectable using SPDT switches, four output indicators,
Circuit diagram Printed & connections for various input &
outputs brought out a sockets on the front panel.
Study of 4-Bit Up Down Counter
F42
To Verify Truth table of RS flops using NAND gates.
Instrument consist of Power Supply 2 Logic '1' & 2 logic '0'
inputs, 1Hz clock pulse, Two output indicators, Circuit
diagram for 'RS' flip-flop is Printed & connections for inputs &
outputs brought out at the sockets, 1 NOT gate for converting
TO STUDY & VERIFY TRUTH TABLE OF 4 BIT UP & DOWN COUNTER USING IC 74193.
Instrument comprises 4 SPDT switches for selecting logic '1'
& logic '0', 1 Hz clock pulse, four output indicators, Circuit
diagram for IC 74193 Printed & connections for various inputs
& outputs brought out at the sockets, two switches for
F42A STUDY & VERIFY TRUTH TABLES OF 'JK' & 'JK MASTER SLAVE' FLIP FLOP
To verify truth table of 'JK' & "JK Master Slave' flip flops using
IC 7472 & IC 7476. Instrument consist of Power Supply
switches provided for selecting logic '1' & logic '0', 1 Hz clock
pulse, Two output indicators. Circuit diagram for 'JK' & 'JK
Master slave' flip-flops are Printed & connections for inputs &
F49 STUDY OF LEFT, RIGHT & PROGRAMMABLE SHIFT REGISTER
To study & verify truth table of Left, Right & Programmable
Shift Register using IC 7495. Instrument comprises of Power
Supply, 4 SPDT switches Circuit diagram for IC 7495 Printed
& connections for various inputs & outputs brought out at the
F56
F56A STUDY OF 2-1 MULTIPLEXER USING AND, OR & NOT GATES
F57
F66 STUDY OF ENCODER & DECODER CIRCUITS (DEMIMAL TO BCD ENCODER
& BCD TO 7-SEGMENT DECODER)
To study Decimal to BCD Encoder
& BCD to 7 segment Decoder.
Instrument comprises of DC Power
Supply 4 SPDT switches for
slecting logic '1' & logic '0', 1 Hz
clock pulse, four output indicators,
Circuit diagram for IC 7490, IC
7447 & 7-segment
F58
STUDY OF 16-1 (SIXTEEN INPUT & ONE OUTPUT) MULTIPLEXER USING IC 74150
STUDY OF ONE INPUT/.FOUR OUTPUT DEMULTIPLEXER USING IC 74155
To study 18 line Demultiplexer circuit IC 74155. Instrument
comprises of Power Supply, 4 SPDT switches for selecting
logic '1' & logic '0', four output indicator, Circuit diagram for IC
74155 Printed & connections for various inputs & outputs
brought out at sockets on front panel.
F59
F70
STUDY OF 4-16 (ONE INPUT/SIXTEEN OUTPUT) DEMULTIPLEXER USING IC 74154
STUDY OF RAM (RANDOM ACCESS MEMORY) CIRCUIT
To study and verify the truth table of RAM circuit. Instrument
comprises of DC Power Supply 5VDC, 10 logic inputs
selectable Instrument comprises of DC Power Supply 5VDC,
10 logic inputs selectable using SPDT switches, 4 LED output
indicators, IC 7489 placed inside & connections brought out
at sockets on the front panel.
F43A DIGITAL TRAINER TO STUDY & VERIFY TRUTH TABLES OF FLIP FLOPS
To study & verify Truth table of
'RS', 'D' Type, 'T' Type, 'JK' & 'JK
Master slave' flip flops using
T T L I C ' s .
Instrument comprises of Power
Supply, 4 logic inputs, logic '1' &
logic '0' selectable using
switches, 1 Hz clock pulse, Two
output indicators, Circuits
diagram for
'RS', 'JK' & 'JK Master Slave' flip-flops Printed, their
STUDY OF 8-1 LINE (FOUR INPUT & ONE OUTPUT) MULTIPLEXER USING IC 74153
To study 8-1 line Multiplexer circuit using. Instrument
comprises of Power Supply, 6 sockets for logic '1' & logic '0'
each, one output indicator, Circuit diagram for IC 74153
Printed & connections for various inputs & outputs brought
BCD TO DECIMAL DECODER USING IC. 7492.
Instrument consist 4 spot
switches for selcting logic '1',
'0'. Ten LED's for output.
STUDY & VERIFY TRUTH TABLES OF 'RS' & 'D' TYPE FLIP FLOP USING NAND GATES
F78
ANALOG/DIGITAL TRAINER (BREAD BOARD TYPE)
The instrument comprises 6 variable resistors, Power
Supplies ±5V, ±15/Variable), ±15 Volt Fix, 1 Hz to 250 KHz.
Function Generator, clock pulse, logic output, logic input, two
P O P U L A R S C I E N C E A P PA R AT U S W O R K S H O P S P V T. L T D .
Phone : 91-171-2600082, 2641462 (O),4006082 , +91-94160-20462 (M) Telefax : 91-171-2641462
11
ELECTRONICS
F79
LOGIC GATE CIRCUIT TRAINER/DIGITAL COMPUTER-II [BREAD BOARD MODEL]
STUDY OF TRANSMITTER & RECEIVER USING FIBER OPTICS CABLE
1.Study and verify Truth tubes of Logic Gates.
2.Verification of Boolean identities & Demorgan's theorems.
3.Study and verify truth tables of Digital Addres and Sub
tractors
4.Study of Flip-Flops and verification of their truth tables.
5.Study of Counters, Shift Registers and verification of their
truth tables.
6.Study of Encoders, Decorders and verification of their
truth tables.
7.Study of Multiplexers, Demultiplexers and verification of
their truth tables.
Instrument comprises of Two DC Regulated Power
Supplies of 5VDC/1Amp & ±15VDC/150mA, 10 Logic
inputs with LED indicators selectable using SPDT switches,
1Hz clock pulses. Bread Board is mounted on front panel to
perform various experiments, 10 number logic output
To construct a Optical Transmitter and calculate its Output
Power. Transmission of Signal through Fiber Optic Cable. To
construct a Optical Receiver and calculate its output power.
To study the Attenuation of Signal when transmitted from
Transmitter to Receiver end. Instrument comprises of DC
Power Supply 6VDC and 3VDC. Preamplifier stages consists
of MIC (Microphone), Photodetector, Transistors (548) and
biasing network Resistance and Capacitors. Power amplifier
stages with impedance matching transformers (Driver
Transformers, Transistors (8550) and biasing network of
Resistances and Capacitors. Output section having LEDs
LOGIC GATE CIRCUIT TRAINER USING TTL IC'S
Verify truth tables of TTL logic gates, Booleon expressions,
De-Morgan's Theorems, Adders, Sub stractors, Flip Flops,
Counters, Shift Registers, Encoders, Decoders, Multiplexers
&
De-multiplexers using 74 series of
TTL IC's.
Instrument comprises of 10 Debunced logic inputs, 10 red
LED output indicators, 5 VDC/1 Amp Regulated short circuit &
overload protected Power Supply, 1 Hz clock pulse, all the
TO VERIFY SWITCH DEBOUNCER
Using I.C. 7400. The Kit consist 1 spot switch for input & two
output LED's. To measure the output voltage sockets are also
provided.
TO MEASURE THE CLOCK PULSE I.C. 7400
The Kit is to measure the clock pulse using NAND Gate I.C
have 1 switch for input & output on LED with terminal to
measure the clock pulse frequency.
F72 ANALOG TO DIGITAL (A/D) CONVERTER
To study analog to Digital & Digital to Analog convertors using
R-2R network & Successive Approximation Method.
Instrument comprises of DC Regulated Power Supplies
5VDC/100mA, 0-10V DC/200mA, +15 VDC/250mA, 1
Voltmeter, 4 SPDT switch provided for selecting logic '1' &
logic '0', one output indicator, Circuit diagram Printed on the
front panel & connections of various inputs & output brought
F73A DIGITAL TO ANALOG (D/A) CONVERTOR USING R-2R NETWORK
To study Digital to Analog converter using R-2R network.
Instrument comprises of DC Regulated Power Supplies
5VDC/150mA, 15VDC/150mA, 1 Voltmeter, 1 SPDT switches
provided for selecting logic '1' & '0', one output indicator,
Circuit diagram printed on the fron panel & connections of
F73 DIGITAL TO ANALOG (D/A) CONVERTER USING WEIGHTED REGISTER NETWORK
To study digital to analog convertors using weighted register
network. Instrument comprises of DC Regulated Power
Supplies 5VDC/150mA, + 15 VDC/150mA, 1 Voltmeter, 4
SPDT switches provided for selecting logic '1' & logic '0', one
output indicator, Circuit diagram printed on the front panel &
STUDY OF AMPLITUDE MODULATION & DEMODULATION
Measurement of Amplitude Modulation Index (Depth of
modulation), side band frequencies (upper side band & lower
side band) and Frequency of demodulated signal.
Instrument consists of DC Regulated Power Supply , Sine
wave Oscillator 100 Hz - 1KHz Frequency Circuit diagram
drawn & Components placed on the panel. Connections of
Supplies & Components brought on terminal
Accessories : RF Signal Generator PSAW-92 and CRO
STUDY OF FREQUENCY MODULATION & DEMODULATION
Measurement of Frequency Modulation Index (Depth of
modulation), side band frequencies (upper side band & lower
side band) and Frequency of demodulated signal.
Instrument consists of DC Power Supply, Square wave
Oscillator 1KHz Frequency Output, Circuit diagram dream &
Components placed on panel. Opt. CRO PSAW -96 & RF
STUDY OF FREQUENCY MODULATION
Measurement of Frequency Modulation Index (Depth of
modulation) Comprises of DC Power Supply, since wave
Oscillator with 1KHz Frequency Output, Circuit diagram
printed & Components placed on the panel. Connections
STUDY OF PULSE AMPLITUDE MODULATION & DEMODULATION
Measurement of Pulse Amplitude Modulation Index (Depth of
modulation) and Frequency of demodulated signal.
Comprises of DC Regulated Power Supply, AF Sine wave,
carrier wave oscialltor using IC 555, Circuit diagram Printed &
Components mounted behind the panel. Connections of
Supplies & Components brought on terminals.
Opt. CRO PSAW-96.
a.Study of Pulse Amplitude Modulation
b.Study of Pulse Amplitude Demodulation
c. Study of Pulse Width Modulation & Demodulation
Modulation of Carrier Signal in Pulse Width Mode and
STUDY OF PULSE POSITION MODULATION & DEMODULATION
Modulation of Carrier Signal in Pulse Position Mode and
Frequency of demodulated Sginal. Instrument comprises of
DC Regulated Power Supply 5 VDC/150mA, AF Sine wave
Oscillator with 100 Hz. 10KHz Frequency Output, RF
Oscillator using IC 555, Circuit diagram printed &
Components mounted behind the panel. Connections of
supplies & Components brought out at 4mm Sockets.
P O P U L A R S C I E N C E A P PA R AT U S W O R K S H O P S P V T. L T D .
E-mail : [email protected] Website : www.psawcatalogue.com, www.popularscientific.com
12
ELECTRONICS
STUDY OF PULSE POSITION & PULSE WIDTH MODULATION
DECADE CAPACITANCE BOX
Modulation of Carrier Signal in Pulse Position & Pulse Width
Mode using External AF Signal and Frequency of
Demodulated Signal.
Instrument comprises of DC Regulated Power Supply 5
VDC/150mA, Carrier Wave Oscillator using IC 555, Circuit
diagram printed & Components mounted behind the panel.
Connections of Supplies & Components brought out at 4mm
Sockets.
Opt. Audio Frequency Function Generator PSAW -93 and
Easy operated band switch mounted on bakelite panel,
Housed in teak wook case.
Single Dial .1 mfd to 1 mfd
2 Dials .01 mfed to 1.1 mfd
3 Dials .001 mfd to 1.11 mfd
DECADE RESISTANCE BOX
minimum contact resistance, mounted on bakalite sheet
with terminals
Single Dial 1K Ohms to 10K Ohm
2 Dials 10 Ohms to 1000 Ohms
3 Dials 1 Ohms to 1000 Ohms
STUDY OF PHASE LOCKED LOOP (PLL) CIRCUIT USING IC 565
To study the phase locked loop circuit and calculate the lock
range Frequency and capture range Frequency. Instrument
comprises of Two DC Regulated Power Supplies, IC 565,
combination of Resistance, Capacitors & One Potentiometer
connected inside & Connections brought out at front panel.
Opt. Audio Frequency Function Generator PSAW -93 and
1
ACTIVE & PASSIVE FILTER CIRCUITS (STUDY OF FREQUENCY RESPONSE)
CIRCUIT DIAGRAM FOR ALL THE FILTERS IS PRINTED ON PANEL AND
TE-93
COMPONENTS PLACED ALONG, CONNECTIONS OF IMPORTANT POINTS
&
BROUGHT OUT AT SOCKETS. REQUIRE AUDIO FREQUENCY FUNCTION
CRO TE-96
GENERATOR
Study of "T" type Passive Low Pass, High Pass, Band
Pass & Band Stop; Filters
Study of "T" type Passive Constant K High Pass Filter
Study of M-Derived "T" type Passive Low Pass Filter
Study of M-Derived "T" type Passive High Pass Filter
Study of "p" type Passive Low Pass, High Pass, Band Pass
& Band Stop Filter
Study of "p" type Passsive Low Pass Filter
Study of "p" type Passive Band Pass Filter
Study of "p" type passive High Pass Filter
Study of "p" type Passive Constant K High Pass Filter
Study of Twin-T Active Notch Filter using Op-Amplifier
Study of Active Filters (Low Pass, IInd order Low Pass, &
High Pass Filter) using Op-Amplifier.
Note : All the Passive Filter Circuit Kits has been prepared
using Passive Components (e.g. using Resistances,
2
POWER SUPPLIES : MODEL
Main = 220V 50HGz. H.T. Output 0 to 300 Volts 30mA. L.T.
6.3 V 3 Amps.
Bias = 0 to 20V ±5mA with two meters for H.T. Volt and
Current.
3
POWER SUPPLIES : MODEL
Stabilized Power Supply Main 230 Volt 50 Hz. Out put H.T. 0
to 300V 50mA. L.T. - 6.3 Volt 3 Amps. Bias = 0 to 25V positive
and negative, Stabilization + 1% with three meters for HT
Volts. He current and bias Voltage suitable for Triode value
4
POWER SUPPLIES : MODEL
Same as above, output, current 100mA. With three
meters for continuous working suitable for electroforsis
5
STANDARD FILTERS
POWER SUPPLIES : MODEL
Dual Power Supply for Pentode Valve Experiment, both
stabiles ±1% workable on 220 Volt 50 Hz. With five meters.
HT1 = 0 to 300 Volts 50 mA
HT 2 = 0 to 300 Volts 25 mA
Bias = 0 to 25 volts 5 mA
L.T. = 6.3 Volt 3 Amps.
Set of Eight Filters Optical
Set of Five Filters Optical
Set of Three Filters Optical
TRANSFORMER HIGH VOLTAGE
For Gas discharge tube. 2.5, 3, 3.5, 4KV.
POWER SUPPLIES : MODEL
The Power supplies are built in suitably sized steel cabinet
employing modern technique and circuit, workable on 220 V
50 Hz. Meters for measuring voltage and current are built in
protection with fuse or automatic.
Output HT = 0 to 300 Volts 30mA. LT. Variable to 1 to 6, 3
Amps with 2 meters for Volt/Current. Suitable for Diode Valve
5
DECADE INDUCTANCE BOX
Very low contact resistance band switch mounted on a
bakelite panel and teak wood case.
Single Dial .1 H to 1 H
2 Dials .01, H to 1.1 H
3 Dials .01 H to 11.1 H
4 Dials .001 H to 11.1 H
FIXED VOLTAGE I.C. REGULATED POWER SUPPLIES
High quality, well filtered giving smooth fixed D.C. Voltage.
Deal for running many training boards like operational
amplifiers (Type-741), Integrated Circuit Timer (Type-555)
(A) 5V or 6V at 500 mA
(b) 5V or 6V at 1A
(c) 9V or 12V at 500 mA
(d) 9V or 12V at 1A
P O P U L A R S C I E N C E A P PA R AT U S W O R K S H O P S P V T. L T D .
3724, Opp. Kali Bari Mandir, Ambala Cantt 133001 Haryana (India)
13
ELECTRONICS
FIXED VOLTAGE I.C. REGULATED DUAL POWER SUPPLIES
11
Two fixed voltages are provided in this unit.
(a) ±5V or ±6V at 500 mA
(b) ±5V or 6V at 1A
(c) ±9V or ±12V at 500 mA
(d) ±9V or 12V at 1A
(e) ±15V or ±18V at 500 mA
Dual Solid State Power Supply Variable from 0 to 15 Volts
positive and 0-15 Volts negative at 500 mA continuously
variable and + 5 Volts fixed supply at 400 mA for operational
amplifiers and other I.C. experiments with two meters.
Regulation ±0.1% with short circuit protection and overload
12
7
REGULATED POWER SUPPLY, MODEL
Two fixed voltages are provided in this unit.
(a) ±5V or ±6V at 500 mA
(b) ±5V or 6V at 1A
(c) ±9V or ±12V at 500 mA
(d) ±9V or 12V at 1A
(e) ±15V or ±18V at 500 mA
(f) ±15V or 18V at 1A
Application
:
General purpose low cost laboratory
Power source ideally suited for
analog
8
Output
+12V
:
and digital IC’s
Four fixed voltages, viz. +5V, -5V,
Current
Regulation
:
:
and -12V
300mA max. for each
±0.05% for no load to full load
DIGITAL REGULATED POWER SUPPLY
Output Voltage
a) 0-15V
(b) 0-15V
(c) 0-15V
(d) 0-15V
(e) 0-15V
(f) 0-30V
(g) 0-30V
(h) 0-30V
(i) 0-30V
Meters
2DPM(3½ digit)
2DPM(3½ digit)
2DPM(3½ digit)
2DPM(3½ digit)
2DPM(3½ digit)
2DPM(3½ digit)
2DPM(3½ digit)
3A
5A
2DPM(3½ digit)
2DPM(3½ digit)
Application : EHT source for photo multiplier tubes and
other radiation detectors.
Polarity : +ve or -ve as required. Output : 0 to 1500V
continuously variable Max. Current : 1 mA Load
Regulation : ±.5% for no load to full load Display : 3½ digit,
7 segment LED display with auto polarity
Power Supply : 220V ±10%, 50 Hz
Protection : Protected against overload and short circuit by
POWER SUPPLY MODEL
Most useful as stand by Dual Power Supply for Transistors
and I.C. experiments workable on 220 Volts 50 Hz, can
deliver output 0-30 Volts, at 1 Amps Positive and 0-30 Volts at
1 Amps. Negative, Stabilization ±0.1% with four meters.
10
POWER SUPPLY MODE
This supply is designed to meet requirement of general
laboratory Continuously variable 0 to 30 V.D.C. at current 0 to
3 Amps, continuous. Load regulation ±.01% line regulation
BATTERY CHARGERS
All battery chargers are compiled in steel cabinet workable on
220 V 50 Hz. protected with fuse. Meter for output current.
Full wave bridge circuit is employed. Tested for continuous
operation.
Model PSAW -15
Model PSAW -16
Model PSAW -17
Model PSAW-18
Model PSAW-19
Model PSAW-20
Model PSAW-21
6/12V 2 Amps.
18V 2 Amps : Automatic
6/12V 3 Amps.
6/12V 4 Amps.
6/12V 5 Amps.
6/12V 6 Amps.
18V 3 Amps : Automatic
BATTERY ELIMINATORS
Output Current
1A
2A
3A
5A
10A
1A
2A
HT-11 HIGH VOLTAGE POWER SUPPLY, MODEL
9
POWER SUPPLY MODE
POWER SUPPLY MODEL
Transistorised, workable on 220 Volts 50 Hz. Variable: 0-30
Volts current 1 Amps, with 2 meters for Volts and current
Stabilization ±5%.
Workable on 220V 50 Hz. Housed in steel cabinet. Socket or
Band-Switch provided for Selection of Volts output, with
ON/OFF switch and main indication.
Model PSAW-23
Model PSAW-24
Model PSAW-25
Model PSAW-26
Model PSAW-27
Model PSAW-28
2 to 6 V 1 Amps.
2 to 12 V 2 Amps.
2 to 12 V 3 Amps.
2 to 12 V 4 Amps.
2 to 12V 5 Amps.
2 to 12V 6 Amps.
Higher Voltage/current Battery Eliminators and Chargers can
TRANSFORMERS & STABILIZERS
Triode Transformers are wound with double enamelled
copper wire and on cores of silicon alloy steel and vaccum
MANUAL VARIABLE TRANSFORMERS
Model PSAW-29
Model PSAW-30
Model PSAW-31
Model PSAW-32
Model PSAW-33
.2 VA
.3 VA
,5 VA
1 KVA
1.5 KVA
AUTOMATIC TRANSFORMERS
Model PSAW-35
Model PSAW-36
Model PSAW-37
Model PSAW-38
P O P U L A R S C I E N C E A P PA R AT U S W O R K S H O P S P V T. L T D .
Phone : 91-171-2600082, 2641462 (O),4006082 , +91-94160-20462 (M) Telefax : 91-171-2641462
.5 VA
1 KVA
1.5 KVA
2.5 KVA
14
ELECTRONICS
Model PSAW-40
Model PSAW-41
Model PSAW-42
Transformer for Microscope.
Demonstration Transformer.
Sodium lamp Transformer 35
Watt.
Transformer High Voltage for
Model PSAW-43
DIMMERSTATE/VARIAC/AUTO TRANSFORMER
Variac These variable transformer deliver continuously
variable A.C. voltage. The output is variable from 0-270 Volts
from mains input of 240 volts. Contact between the winding
and load is through a carbon brush which covers at least one
turn of wire at all times. The areas of winding swept by the
brush is plated with metal which eliminates oxidations and
ensures a long working life with negligible maintenance.
Specifications :
Constructions : Enclosed in a metal box, has air cooling. The
voltage is adjusted and indicated by a knob and dial on the
t
o
p
.
Termination : Mains input via main cable. Output via insulated
4mm socket terminals as well as 3-pin 5 amp. socket.
Indication : An ON/OFF and indicator is provided.
Overload Protection : Slow blow fuse in output line.
Output Volts :
0-240 V (line voltage connection)
0-270 V (over voltage connection)
This sturdily constructed Auto Transformer, ideal for
operating heating devices, A.C. Motors and others
equipment reguiring adjusting input voltage. This item is
supplied with different current capacities as per requirement
in hand. Output voltage 0-270V remains the same in each
case. Rest specifications are as above.
a) Current Capacity : 2 Amp.
b) Current Capacity : 4 Amp.
UNIVERSAL MOISTURE METER
UNIVERSAL MOISTURE METER MODEL AG-U
The most versatile instrument for the measurement of
Moisture content in Grains, Seeds and Pulses. Operatable on
220 V 50 Hz and Battery. The instruments is made to operate
very easily and takes less than a minute to complete the
test. rugged in construction, aluminum casted and the
electrical unit is contained in. the bevel gear mechanism is of
best steel. The whole instrument is protected in wooden box.
Specification :
Measuring Range
Accuracy
Dimension
Weight
cover.
Power Supply
8-40%
± 0.2%
40 x 32 x 17 cm
19.5 Kg. without wooden
4 Battery Cells or 220 V 50 Hz
NOTE : The instrument is approved by food corporation of
TRIODE MOISTURE METER
TRIODE MOISTURE METER MODEL AG-1
: is a light weight portable instrument designed to detect
moisture in food grains, pulses, oil seeds, vegetable seeds,
spices and other granular substances. The grains are
compressed & conductivity noted.
It is a self contained instrument for compressing the sample
to predetermined thickness and then sensing conductivity on
a analoguye meter. A thermometer is installed to take instant
temperature and for easy reading of moisture percentage
circular scale is given on the top of instrument.
The electrical circuit is designed for very low power
consumption and it works on two small battery cells or on AC
mains.
Specification :
Measuring Range :
Accuracy
8-40%
± 0.2%
GRAINS MOISTURE METER
GRAINS MOISTURE METER MODEL AG-5
Direct Reading Microprocessor system with automatic
temperature compensation workable on battery and mains.
L.E.D. display, consistent reading, fault free operation.
Specification :
RANGE
SAMPLE
DIMENSION
:
:
:
8 TO 40%
6 GRAINS or 200 mg.
1/2
1/2
7 “ x 7 “ x 5”
PORTABLE LIGHT WEIGHT, SELF CONTAINED WITH ALL
ACCESSORIES
We are manufacturer of this item since 1962, our moisture
meters are approved by food corporation of India, central
ware housing corporation state ware housing corporation
and food & supply department, rice mills and agriculture
department and search labs.
DIGITAL MOISTURE METER
DIGITAL MOISTURE METER MODEL AG-3
Micro controller based Universal type, with rugged
mechanical construction, accurate moisture content is direct
readable on 3 digit L.E.D. display.
temperature and
conductive result are automatically compensated for final
moisture percentage reading. No conversion table is needed
Specification :
Range
Accuracy
Dimension
Main Featurers
8-40%
± 0.2%
29.5 x 17 x 19.5 cm
· Easy operation, press and take reading
· Direct Reading on digital display
· No Adjustment
P O P U L A R S C I E N C E A P PA R AT U S W O R K S H O P S P V T. L T D .
E-mail : [email protected] Website : www.psawcatalogue.com, www.popularscientific.com
15
ELECTRONICS
INFRARED MOISTURE BALANCE
INFRARED MOISTURE BALANCE MODEL AG-4
A basic method for determination of moisture content,
measure moisture percentage by weight and drying
simultaneously. Infra Red radiation are reflected by a buld
and its temperature is controlled by a regulator.
Specification :
Range
Accuracy
Dimension
Weight
Sample Weight
Specification :
Range
Accuracy
Dimention
Operation
Electrode Size
0-100 Saturation %
± 0.5%
22 x 10 x 10cm.
Battery 9V
20 Cm.
0-100%
± 0.2%
28 x 35 cm.
20 Kgs. Approx
5 gm, 20gm, 25gmor as
DIGITAL SEED COUNTER
DIGITAL SEED COUNTER MODEL AG-2
With mechanical Viberator, having electronic adjustable
speed for different Grains. 4 digit counter and adjustable
timer. The counting is automatic with Infrared Sensors.
MOISTURE METER FOR WOOD
MOISTURE METER FOR WOOD MODEL PSAW -W
Direct reading of moisture in Timber, Pulp, Cotton wood. the
instr4ument is housed in cabinet highly finished the test
procedure is written on the panel, complete with probe and
battery.
Specification :
Measuring Range
Accuracy
6.8-30%
± 0.5%
MOISTURE METER FOR WOOD MODEL PSAW -WD
Microprocessor based, Digital, high accuracy portable
instrument, workable on battery cells, complete with probe
Automatic temperature compensation.
Specification :
Range
Accuracy
6 to 30%
± 0.3%
MOISTURE METER FOR SOIL
MOISTURE METER FOR SOIL MODEL AG-7
The instrument is calibrated in percentage saturation in soil
and reads from 0-100. It is cell operated on analogue Meter.
With 9V Battery.
Specification :
Range
Accuracy
Dimension
0-100 Saturation %
± 0.5%
22 x 10 x 10 cm.
MOISTURE METER FOR SOIL MODEL AG-8
The instrument is for detecting saturation percentage of water
in soil. It is workable on 9 V Battery 3.5 Digit display. Complete
with 20 cm electrode and wooden box.
P O P U L A R S C I E N C E A P PA R AT U S W O R K S H O P S P V T. L T D .
3724, Opp. Kali Bari Mandir, Ambala Cantt 133001 Haryana (India)
16
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project