Measuring Instrument Catalog for Educational and Research

Measuring Instrument Catalog for Educational and Research
Measuring Instrument Catalog
for Educational and Research Institutions
LCR Meters / Impedance Analyzers
Power Meters / Power Analyzers
Data Acquisition / Oscilloscopes
Data Loggers
Resistance Meters / Battery Testers
Electrometers / Picoammeters
Digital Multimeters
Current Probes / Current Sensors
LCR Meters / Impedance Analyzers
Ideal for measuring these component characteristics:
The ion conductivity of solid electrolytes
(zirconia, electrolyte membranes)
The dielectric constant of foods such as bread dough and chocolate
The frequency characteristics of materials such as
magnetic materials and piezoelectric ceramics
Biological impedance (measuring body fat and visceral fat)
The impedance of the electrolyte in batteries and capacitors
Corrosion of steel rebar in reinforced concrete
The resonance frequency of contactless IC tags
The capacitance (C-V characteristics) of MOS FETs
Capacitance between the ground and plants
(to forecast the length of plant roots)
The impedance of fuel cells
The dielectric constant (C) of LCD cells
Measurement
A rich lineup covering a wide range of measurement frequencies
frequency
Impedance Analyzers
IM7580A
LCR Meters
1MHz ----------------- 300 MHz
IM7581
100 kHz ----------------------------- 300 MHz
IM7583
1MHz ---------------------- 600 MHz
IM7585
1MHz ---------------------------- 1.3 GHz
IM7587
1MHz ---------------------------------- 3 GHz
IM3570
4 Hz -------------------------------------------------------- 5MHz
IM3590
1mHz -------------------------------------------------- 200 kHz
IM3536
4 Hz -------------------------------------------------------------- 8MHz
IM3533
1mHz -------------------------------------------------- 200kHz
IM3523
4 0 Hz --------------------- 200kHz
DC
100mHz
Example application
IM3590
1Hz
10Hz
100 Hz
1kHz
10 kHz
100 kHz
1 MHz
10 MHz
100 MHz
1 GHz
Temperature measurement and time
interval measurement
When used with an optional temperature probe, the Impedance Analyzer IM3590 can display graphs that
include the temperature at which each measurement was made. You can display a temperature characteristics graph by selecting temperature as one axis on the X-Y display. In addition, the instrument can perform time interval measurement with up to 801 points, making it possible to display graphs of variations
over time that include temperature characteristics.
Data describing variations over time obtained by
means of interval measurement
(Change in the capacitance of a laminated ceramic capacitor)
The temperature sensor (Sheath Type Temperature Probe 9478) has
a waterproof sheath, allowing it to be directly inserted into liquids.
Sheath material: SUS316
Waterproofness: EN60529:1991, IP67
Example application
IM3590
Equivalent circuit analysis of electrochemical components
Evaluating electrochemical components and materials by estimating an equivalent circuit during measurement provides a way to
deepen your understanding of the characteristics of reactions,
electrodes, and electrolytes. The Impedance Analyzer IM3590 provides equivalent circuit models for electrochemical components
and materials, allowing it to evaluate liquid resistance, charge
transfer resistivity, and electric double-layer capacitors.
Equivalent circuit
analysis results
Equivalent circuit
model
Equivalent circuit analysis
screen
(Alkaline battery)
2
X-Y display screen
(Temperature characteristics for the capacitance
of a laminated ceramic capacitor)
LCR Meters / Impedance Analyzers
Example application
Evaluation and analysis of transmit/receive coil characteristics
Overview of
contactless power
transfer
Contactless power transfer technology, which lets you charge mobile phones and consumer
electronics like phones, electric toothbrushes, and electric shavers simply by placing them
on a stand, is becoming increasingly common. Research into the commercialization of highcapacity contactless power transfer as a technology for charging electric vehicles and plugin hybrid vehicles is progressing at a rapid pace.
Receive coil
Transmit coil
Overview of
wireless tag
In addition, research into the commercialization of wireless tag technologies such as RF-ID
is also continuing as we move into the “Internet of Things” (IoT) era.
Evaluation and analysis of transmit/receive coil characteristics plays an essential role in
the development of contactless power transfer and wireless tag technologies. Impedance
analyzers such as the IM7585 can analyze not only coil frequency characteristics, but also
values for elements in equivalent circuit models. Use these instruments to optimize coil design.
Wireless tag
Receiver/
transmitter
Equivalent circuit analysis of a loop antenna
C1
IC chip
R1
L1
Loop antenna
Equivalent circuit
Example application
Equivalent circuit analysis results
Evaluation and analysis of the characteristics of piezoelectric elements
Piezoelectric elements convert electric signals to mechanical movement and vice versa.
When an electrical signal is applied externally, the element's shape changes, allowing it to
be used in buzzers and other sound-producing components. Another example is its application in pressure and inclination sensors, whereby an electrical signal in response to changes
in the element's shape is output.
The impedance/frequency characteristics of piezoelectric elements include resonance points
and anti-resonance points. Frequency sweep measurement using an impedance analyzer is
an ideal way to ascertain the frequency of each of those points. Impedance analyzers such
as the IM7585 can analyze not only frequency characteristics, but also values for elements
in equivalent circuit models. Use these instruments to analyze the characteristics of piezoelectric elements.
Overview of piezoelectric element characteristics
Equivalent circuit analysis of a piezoelectric element
C0
L1
C1
Equivalent circuit
R1
Equivalent circuit analysis results
3
LCR Meters / Impedance Analyzers
Instruments do not ship with a test fixture or probe. A test fixture designed specifically for use with the specific Impedance Analyzer is required.
IMPEDANCE ANALYZER IM7580 series
NEW
High-speed, highly stable measurement
Choose from five models to meet your
measurement frequency.
l Compact, half-rack footprint with space-saving test head
l Comprehensive contact check (via DCR testing, Hi-Z reject or waveform judgment)
l Make frequency sweeps, level sweeps and time interval measurements in Analyzer Mode
Model No. (Order Code)
IM7587-01, IM7585-01, IM7583-01, IM7581-01, IM7580A-1 (Connection cable 1m is bunbled)
IM7587-02, IM7585-02, IM7583-02, IM7581-02, IM7580A-2 (Connection cable 2m is bunbled)
Basic specifications
IM7587
IM7585
IM7583
IM7581
IM7580A
1 MHz to 3 GHz
1 MHz to 1.3 GHz
1 MHz to 600 MHz
100 kHz to 300 MHz
1 MHz to 300 MHz
Appearance
Measurement
frequency
Measurement range
(depending on measurement frequency)
Measurement
signal level
Basic accuracy
Power
Voltage
Current
Dimensions Main unit
Test head
and mass
L: 0.0053 nH to 0.795 mH L: 0.0123 nH to 0.795 mH L: 0.0265 nH to 0.795 mH
L: 0.0531 nH to 7.95 mH
L: 0.0531 nH to 0.795 mH
C: 0.011 pF to 1.59 μF
C: 0.0245 pF to 1.59 μF C: 0.0531 pF to 1.59 μF
C: 0.1061 pF to 15.9 μF
C: 0.1061 pF to 1.59 μF
-40.0 dBm to +1.0 dBm
-40.0 dBm to +7.0 dBm
4 mV to 502 mVrms
4 mV to 1001 mVrms
0.09 mA to 10.04 mArms
0.09 mA to 20.02 mArms
Z : 0.65% rdg. θ: 0.38°
Z : 0.72% rdg. θ: 0.41°
215 mm (8.46 in) W × 200 mm (7.87 in) H × 348 mm (13.70 in) D, 8.0 kg (282.2 oz) 215 mm (8.46 in) W × 200 mm (7.87 in) H × 268 mm (10.55 in) D, 6.5 kg (229.3 oz)
90 mm (3.54 in) W × 64 mm (2.52 in) H × 24 mm (0.94 in) D, 300 g (10.58 oz)
61 mm (2.40 in) W × 55 mm (2.17 in) H × 24 mm (0.94 in) D, 175 g (6.2 oz)
Shared specifications
LCR mode, Analyzer mode (sweeps with measurement frequency
Measurement modes and measurement level), Continuous measurement mode
Measurement
Z, Y, θ, Rs (ESR), Rp, X, G, B, Cs, Cp, Ls, Lp, D (tanδ), Q
parameters
Measurable range 100 mΩ to 5 kΩ
Z: 0.00 m to 9.99999 GΩ / Rs, Rp, X: ± (0.00 m to 9.99999 GΩ)
Ls, Lp: ± (0.00000 n to 9.99999 GH) / Q: ± (0.00 to 9999.99)
θ: ± (0.000° to 180.000°), Cs, Cp: ± (0.00000 p to 9.99999 GF)
Display range
D: ± (0.00000 to 9.99999), Y: (0.000 n to 9.99999 GS)
G, B: ± (0.000 n to 9.99999 GS), Δ%: ± (0.000 % to 999.999 %)
Output impedance 50 Ω
Measurement speeds FAST: 0.5 ms (Analog measurement time, typical value)
Contact check, Comparator, BIN measurement (classification),
Panel loading/saving, Memory function, Equivalent circuit
Functions
analysis, Correlation compensation
EXT I/O (Handler), USB communication, USB memory, LAN,
Interfaces
RS-232C (optional), GP-IB (optional)
100 to 240 V AC, 50/60 Hz, 70 VA max.
Power supply
Equivalent circuit analysis function
Analyze individual component values (L/C/R)
for elements in the following five circuits based
on measurement results.
A: Analysis results
SMD TEST FIXTURE (option)
SMD TEST FIXTURE
IM9201
TEST FIXTURE
STAND
IM9200
ADAPTER
IM9906
(3.5mm to 7mm)
TEST HEAD
(Bundled with Hioki impedance analyzer)
4
Frequency range
Compatible package sizes (EIA)
Compatible electrode structure
Maximum voltage
Additional uncertainty
DC to 3 GHz
0201, 0402, 0603, 0805, 1206, 1210
Bottom electrodes
±42 Vpeak (AC+DC)
Impedance : ±Ze [%]
Phase : ±0.58 × Ze [ ° ]
Ze = Ae + (Zse / Zx + Yoe × Zx) × 100
Zx : Measured impedance value [Ω]
Ae : 4 × f 2 [%]
Zse : (100 + 500 × f ) / 1000 [Ω]
Yoe : (10 + 100 × f ) / 1000000 [S]
f [GHz]
SMD TEST FIXTURE IM9201
TEST FIXTURE STAND IM9200
ADAPTER(3.5 mm to 7 mm) IM9906
CALIBRATION KIT IM9905
LCR Meters / Impedance Analyzers
Instruments do not supplied with measurement probes or test fixtures. Please select and purchase the measurement probe or test fixture options appropriate for your application separately.
IMPEDANCE ANALYZER IM3570
CHEMICAL IMPEDANCE ANALYZER IM3590
Model No. (Order Code) IM3590
Model No. (Order Code) IM3570
Single Device Solution for
High Speed Testing and Frequency Sweeping
l LCR measurement, DCR measurement, sweep measurement, continuous
measurement and high-speed testing achieved with one instrument
l High-speed testing, achieving maximum speeds of 1.5ms (1 kHz) and
0.5ms (100kHz) in LCR mode
l Perfect impedance analyzer for testing the resonance characteristics of
piezoelectric elements, C-D and low ESR measurement of functional polymer
capacitors, DCR and L-Q measurement of inductors (coils and transformers)
l Perform frequency sweeps, level sweeps, and time interval
measurements in analyzer mode
l Broad 1 mHz to 200 kHz signal source range supports measurements of
ion behavior and solution resistance
l Continuous measuring and high-speed testing of LCR and sweep
measurements with a single instrument
l Measure internal impedance of batteries with no load
l Perform high-speed sweep measurements in as little as 2 ms
l Basic accuracy of ±0.05% is ideal for applications from component testing to R&D
l Measure LCR impedance for Cole-Cole plots and equivalent-circuit
analyses of electro-chemical components and materials
IM3570
Basic specifications
Measurement modes
Measure Electrochemical Components
and Materials, Batteries, and EDLCs
IM3590
LCR mode, Analyzer mode (Sweeps with measurement frequency and
measurement level), Continuous measurement mode
Measurement
parameters
Basic accuracy
Measurement frequency
Z, Y, θ, Rs (ESR), Rp, Rdc (DC resistance), X, G, B, Cs, Cp, Ls, Lp,
D (tanδ), Q
Z: ±0.08 % rdg. θ: ±0.05°
4 Hz to 5 MHz (5 digits setting resolution, minimum resolution 10 mHz)
V mode/CV mode: 5 mV to 5 Vrms (up to 1 MHz)
Measurement signal level 10 mV to 1 Vrms (1.0001 MHz to 5 MHz), 1 mVrms steps
CC mode: 10 μA to 50 mArms (up to 1 MHz)
(Normal mode)
10 μA to 10 mArms (1.0001 MHz to 5 MHz), 10 μArms steps
Measurement signal level V/CV: 5 mV to 1 Vrms (up to 100 kHz), 1 mVrms steps
(Low impedance high accuracy mode) CC:10 μA to 100 mArms (100 mΩ and 1Ω ranges of up to 100 kHz), 10 μArms steps
Normal mode: 100 Ω, Low impedance high accuracy mode: 10 Ω
Output impedance
0.5 ms (100 kHz, FAST, display OFF, representative value)
Measurement speeds
EXT I/O (handler), RS-232C, GP-IB, USB communication, USB memory,
Interfaces
LAN
90 to 264 V AC, 50/60 Hz, 150 VA max.
Power supply
330 mm (12.99 in) W × 119 mm (4.69 in) H × 307 mm (12.09 in) D, 5.8 kg (204.6 oz)
Dimensions and mass
LCR METER IM3536
Measurement frequency
DC, 4 Hz to 8 MHz
l High-speed measurement of 1ms (fastest time)
l Basic accuracy:±0.05% rdg
l Guaranteed accuracy range from 1 mΩ
l DC bias function: Measure under conditions simulating
actual use or in accordance with industry standards
Basic specifications
Model No. (Order Code)
Measurement
modes
Measurement
parameters
Basic accuracy
LCR mode, Continuous measurement mode (LCR mode / Analyzer mode),
Analyzer mode (Sweeps with measurement frequency and measurement
level, temperature characteristics, equivalent circuit analysis)
Z, Y, θ, Rs (ESR), Rp, Rdc (DC resistance), X, G, B, Cs, Cp, Ls, Lp,
D (tanδ), Q, T, σ (conductivity), ε (dielectric constant)
Z: ±0.05% rdg. θ: ±0.03°
1 mHz to 200 kHz (5 digits setting resolution, minimum resolution 1 mHz)
V mode/CV mode: 5 mV to 5 Vrms, 1 mVrms steps
CC mode: 10 μA to 50 mArms, 10 μArms steps
V mode/CV mode: 5 mV to 2.5 Vrms, 1 mVrms steps
CC mode:10 μA to 100 mArms, 10 μArms steps
Normal mode: 100 Ω, Low impedance high accuracy mode: 25 Ω
2 ms (1 kHz, FAST, display OFF, representative value)
EXT I/O (Handler), USB communication (high-speed), USB memory
Optional: Choose 1 from RS-232C, GP-IB, or LAN
100 to 240 V AC, 50/60 Hz, 50 VA max.
330 mm (12.99 in) W × 119 mm (4.69 in) H × 168 mm (6.61 in) D, 3.1 kg (109.3 oz)
LCR METER IM3533
LCR METER IM3523
Measurement frequency
DC, 1mHz to 200kHz
Measurement frequency
DC, 40Hz to 200kHz
l Basic accuracy:±0.05% rdg
l Built-in low impedance high precision mode
effective for testing low inductance or the ESR
of aluminum electrolysis capacitance
l Frequency sweep testing (IM3533-01 only)
l Basic accuracy:±0.05% rdg
l Built-in comparator and BIN functions
l Rapid 2msec test time
IM3536
LCR, Continuous testing
Z, Y, θ, X, G, B, Q, Rdc (DC resistance), Rs (ESR), Rp,
Ls, Lp, Cs, Cp, D (tanδ), σ, ε
Z: ±0.05 % rdg. θ: ±0.03°
V/ CV: 4 Hz to 1.0000 MHz: 10 mV to 5 V (Max. 50 mA)
Measurement signal
1.0001 MHz to 8 MHz: 10 mV to 1 V (Max. 10mA)
CC: 4 Hz to 1.0000 MHz: 10 μA to 50 mA (Max. 5 V)
level(Normal mode)
1.0001 MHz to 8 MHz: 10 μA to 10 mA (Max. 1 V)
Measurement signal level V/CV: 4 Hz to 1.0000 MHz: 10 mV to 1 V (Max. 100 mA)
(Low impedance high accuracy mode) CC: 4 Hz to 1.0000 MHz: 10 μA to 100 mA (Max. 1 V)
Normal mode: 100 Ω
Output impedance
Low impedance high accuracy mode: 10 Ω
Measurement speeds 1 ms (1 MHz, FAST, display OFF, representative value)
100 to 240 V AC, 50/60 Hz, 50 VA Max.
Power supply
Dimensions and
330 mm (12.99 in) W × 119 mm (4.69 in) H × 230 mm
(9.06 in) D, 4.2 kg (148.1 oz)
mass
IM3533
IM3533-01(Advanced function model)
LCR, Transformer testing (N, M, ΔL), Continuous testing (LCR mode)
-01only: Analyzer, Continuous Testing (Analyzer mode)
Z, Y, θ, Rs (ESR), Rp, Rdc (DC resistance), X, G, B, Cs, Cp, Ls,
Lp, D (tanδ), Q, N, M, ΔL, T
Z: ±0.05% rdg. θ: ±0.03°
V/CV mode: 5 mV to 5 Vrms, 1 mVrms steps
CC mode: 10 μA to 50 mArms, 10 μArms steps
IM3523
LCR, Continuous testing
Z, Y, θ, Rs (ESR), Rp, Rdc (DC resistance),
X, G, B, Cs, Cp, Ls, Lp, D (tanδ), Q
Z: ±0.05% rdg. θ: ±0.03°
V/CV mode: 5 mV to 5 Vrms,
1 mVrms steps
CC mode: 10 μA to 50 mArms,
10 μArms steps
V/CV mode: 5 mV to 2.5 Vrms, 1 mVrms steps
--CC mode: 10 μA to 100 mArms, 10 μArms steps
Normal mode: 100 Ω
100 Ω
Low impedance high accuracy mode: 25 Ω
2 ms (1 kHz, FAST, display OFF, representative value)
2 ms (1 kHz, FAST, representative value)
100 to 240 V AC, 50/60 Hz, 50 VA Max.
100 to 240 V AC, 50/60 Hz, 50 VA Max.
330 mm (12.99 in) W × 119 mm (4.69 in) H × 168 mm (6.61 in) 260 mm (10.24 in) W × 88 mm (3.46 in)
D, 3.1 kg (109.3 oz)
H × 203 mm (7.99 in) D, 2.4 kg (84.7 oz)
5
Power Meters / Power Analyzers
Depending on the model, please purchase separately-sold voltage cords and current sensors appropriate for the application.
Use for measurement applications like these…
Measuring and managing power use as part of energy-saving activities
Evaluating the conversion efficiency of inverters with SiCs
Analyzing vector control of high-efficiency synchronous motors
Measuring reactor loss in chopper circuits
Measuring the efficiency of power conditioners used in solar power systems
Measuring loss in high-frequency transformers
Evaluating the transmission efficiency of wireless power systems
Evaluating the efficiency of high-efficiency motors
Measuring the power consumption, standby power,
and harmonics of household electronics
Measuring the energy efficiency of electric vehicles
Pulse
encoder
Inverter
Battery
Torque
sensor
Motor
Step-up DC
DC
Reactor
Load
Load
Power supply
Displays torque signal and pulse encoder waveforms
Variety of clamp sensor corresponding to the high frequency band
5 MS/s speed and high 18-bit resolution
make SiC measurements a reality
High-frequency and low power factor
device evaluation
High resolution is required for the high precision measurement of PWM
waveforms for SiC semiconductors with low ON resistance. TrueHD
18-bit is achieved at a level of precision that has never been seen before.
Reactors are used for high harmonic current suppression
as well as the voltage step up/down of chopper circuits.
The PW6001’s outstanding high frequency characteristics,
highspeed sampling, and noise-suppressing performance are
extremely effective in evaluating high-frequency, low power
factor devices.
2
AC/DC Current Box PW9100’s phase characteristic
compensation example (representative value)
0
degree [ °]
Measurement of very low power
levels when switching is Low
Current Sensor Phase Shift Function
In addition to the PW6001’s flat, broad frequency characteristics, sensor phase error compensation allows highly accurate
high-frequency and low power factor device analysis.
-2
-4
Phase
Phase (when using the phase
-6
compensation function)
-8
16-bit resolution
Hioki 3390
Input waveform
-10
18-bit resolution
PW6001
10
100
1k
10 k
100 k
Frequency [Hz]
1M
10 M
POWER ANALYZER PW6001
NEW
Improve Power Conversion Efficiency
Industry-Leading Accuracy and Max. 12 Channels
(When synchronizing two 6-channel models connected via optical link)
l Basic accuracy of ±0.02%*1 for power measurement (*1 PW6001 accuracy only.
Instrument delivers accuracy of ±0.04% even after the current sensor accuracy has been added.)
l High noise resistance and stability
(80 dB/100 kHz CMRR, ±0.01%/°C temperature characteristics)
Model No. (Order Code)
PW6001-01 (1 ch) PW6001-04 (4 ch)
PW6001-02 (2 ch) PW6001-05 (5 ch)
PW6001-03 (3 ch) PW6001-06 (6 ch)
Motor analysis, D/A output
PW6001-11 (1 ch) PW6001-14 (4 ch)
PW6001-12 (2 ch) PW6001-15 (5 ch)
PW6001-13 (3 ch) PW6001-16 (6 ch)
l 10 ms data refresh while maintaining maximum accuracy
l DC basic accuracy of ±0.02%*2, which is key for stable, accurate efficiency
measurement (*2 PW6001 accuracy only)
l Accurate measurement even when the load is characterized by large fluctuations;
TrueHD 18-bit resolution, 5MS/s sampling
l Wide frequency bandwidth of DC, or 0.1 Hz to 2 MHz
Basic specifications
Measurement line type Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire, three-phase 4-wire
Max. 6 channels; each input unit provides 1 channel for simultaneous voltage and current input
Number of input
(Voltage measurement unit: Photoisolated input, resistance voltage divider, Current measurement unit: Isolated input from current sensor)
channels
Voltage range: 6 to 1500 V, 8 ranges
Measurement
Current range (Probe 1) : 400 mA to 1 kA (depends on current sensor)
range
Current range (Probe 2) : 100 mA to 50 kA (depends on current sensor)
DC, 0.1 Hz to 2 MHz
Frequency band
Voltage: ±0.02 % rdg. ±0.02 % f.s. Current: ±0.02 % rdg. ±0.02 % f.s. + current sensor accuracy
Basic accuracy
Active power: ±0.02 % rdg. ±0.03 % f.s. + current sensor accuracy
Voltage (U), current (I), active power (P), apparent power (S), reactive power (Q), power factor (λ),
Measurement items phase angle (φ), frequency (f), efficiency (η), loss (Loss), voltage ripple factor(Urf), current ripple
factor (Irf), current integration (Ih), power integration (WP), voltage peak (Upk), current peak (Ipk)
Harmonic measurement Harmonic active power, select calculation orderfrom 2nd order to 100th order
Waveform recording Always 50 kS/s, 16 bits, Recording capacity: 1 Mword × ((voltage + current) × number of channels + motor waveforms)
100 to 240 V AC, 50/60 Hz, 200 VA max.
Power supply
Dimensions and mass 430 mm (16.93 in)W × 177 mm (6.97 in)H × 450 mm (17.72 in)D, 14 kg (49.4 oz) (PW6001-16)
Note: Optional voltage cords and current sensor are required for taking measurements. Specify the number of built-in channels and
inclusion of Motor Analysis & D/A Output upon order for factory installation. These options cannot be changed or added at a later date.
6
High-Precision Sensors
PW9100-03 (Direct Current Input: 50 A AC/DC input, 3 ch)PW910004 (Direct Current Input: 50 A AC/DC input, 4 ch)
CT6862-05 (Pull-through type: 50 A AC/DC input)
CT6863-0 (Pull-through type: 200 A AC/DC input)
(Pull-through type: 500 A AC/DC input)
9709-05
CT6865-05 (Pull-through type: 1000 A AC/DC input)
CT6843-05 (Clamp type: 200 A AC/DC input)
CT6841-05 (Clamp type: 20 A AC/DC input)
CT6844-05 (Clamp type: 500 A AC/DC input)
CT6845-05 (Clamp type: 500 A AC/DC input)
CT6846-05 (Clamp type: 1000 A AC/DC input)
Wide-Band Current Probes
CT6701
CT6700
3276
3275
3274
3273-50
(DC to 120 MHz bandwidth, 1 mA to 5 A rms)
(DC to 50 MHz bandwidth, 1 mA to 5 A rms)
(Wide DC to 100 MHz bandwidth, 10 mA-class to 30 Arms)
(Wide DC to 2 MHz bandwidth, up to 500 A rms)
(Wide DC to 10 MHz bandwidth, up to 150 A rms)
(Wide DC to 50 MHz bandwidth, 10 mA-class to 30 Arms)
Voltage measurement
L9438-50 (Black/ Red, Alligator clip ×2)
L1000
(Red/ Yellow/ Blue/ Gray each 1, Black 4, Alligator clip ×8)
Power Meters / Power Analyzers
Depending on the model, please purchase separately-sold voltage cords and current sensors appropriate for the application.
POWER ANALYZER 3390
Model No. (Order Code)
3390 (main unit, clamp sensor is sold separately)
AC/DC CURRENT
SENSOR 9709
Maximum accuracy of ±0.16% achieved with current sensors (when combined with the 9709)
l Measure the primary and secondary sides of inverters
l Advanced motor analysis functions
l Wide band measurement:DC, 0.5 Hz to150 kHz
l Display and save Waveforms at 500 kS/s sampling
l Portable design can be transported away from the workbench
l Supports inverter noise measurement - Perform harmonic analysis
and noise analysis while simultaneously viewing the inverter waveform
Basic specifications
Measurement line Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire, three-phase
4-wire, Voltage 4 channels, Current 4 channels, Isolated between each channel
type
Number of input channels Voltage: 4 ch (Isolated input) Current: 4 ch (Isolated input)
Voltage range: 15 to 1500 V, 7 ranges, Current range: 400 mA to 500 A
Measurement range (depends on current sensor, 20A/ 50A/ 200A/ or 500A rated)
DC, 0.5 Hz to 150 kHz (Synchronization frequency range: 0.5 Hz to 5 kHz)
Frequency band
Voltage: ±0.05 % rdg. ±0.05 % f.s.
Current: ±0.05 % rdg. ±0.05 % f.s. + current sensor accuracy
Basic accuracy
Active power: ±0.05 % rdg. ±0.05 % f.s. + current sensor accuracy
Voltage, Current, Voltage/current waveform peak, Active power, Reactive
Measurement
power, Apparent power, Power factor, Phase angle, Frequency, Current inteitems
gration, Power integration, Efficiency, Loss, Voltage/current ripple factor
RMS value, Content factor, Phase angle, Phase difference, Total distortion,
Harmonic
Disequilibrium factor (Number of harmonic orders: Max. 100th order)
measurement
Noise measurement Maximum analysis frequency: 100 kHz
Rectification switching, Scaling, Averaging, Efficiency/loss calculation, Δ – Y calculation
Functions
100 to 240 V AC, 50/60 Hz, 140 VA max.
Power supply
Dimensions and mass 340 mm (13.39 in)W × 170 mm (6.69 in)H × 157 mm (6.18 in)D, 4.8 kg (169.3 oz)
Optional Functions
Voltage, torque, rotation, frequency, slip, motor output
Motor testing
16 channels, Waveform output (8ch Max., ±2V)/Analog output (DC±5V)
D/A Output
CLAMP ON POWER LOGGER PW3360
Model No. (Order Code)
Basic specifications
PW3360-20 (English model, main unit only)
PW3360-21 (English model, with harmonic
analysis function)
Portable Power Loggers
for Energy Audits and
Energy Conservation
l Supports single to three-phase, 4-wire circuits
l Measure between 90V to 780V
l Measure leakage current from a range setting as low as 50.000 mA
(using an optional sensor)
l The QUICK SET function guides you in making the right connections
l Choose PW3360-21 for harmonic measurements up to the 40th order
Dimensions and mass 180 mm (7.09 in)W × 100 mm (3.94 in)H × 48 mm (1.89 in)D, 550 g (19.4 oz)
For load current measurement
(1 sensor necessary for single-phase measurements, and 2 or 3 sensors required for 3-phase measurements)
POWER LOGGER VIEWER SF1001
9694 (5A AC rated current)
For leak current measurement
9660 (100A AC rated current)
9675 (10 A AC rated current)
9661 (500A AC rated current)
9657-10 (100 A AC rated current)
9669 (1000A AC rated current)
CT9667-01/-02/-03 (5000/500 A AC rated current)
9695-02* (50A AC rated current, Not CE marked)
9695-03*(100A AC rated current, Not CE marked) *Requires the Connection cord 9219
Data can be loaded into a PC for expanded
display, aggregation and analysis
l Trend graph display function
l Summary display function
l Waveform display
l Harmonic display
Measurement line 50/60 Hz, Single phase 2 wires (1/2/3 circuits), Single phase 3 wires (1 circuit), Three
phases 3 wires (1 circuit), Three phases 4 wires (1 circuit), Current only: 1 to 3 channels
type
Voltage, current, frequency, active power, reactive power (with lag/lead display),
apparent power, power factor (with lag/lead display) or displacement power factor (with lag/lead display), active energy (consumption, regeneration), reactive
energy (lag, lead), active power demand quantity (consumption, regeneration),
Measurement
reactive power demand quantity (lag, lead), active power demand value (conitems
sumption, regeneration), reactive power demand value (lag, lead), and other.
[PW3360-21 only]: Harmonic voltage level, harmonic current level, harmonic
power level, content percentage, phase angle, total harmonic distortion (THD-F
or THD-R), up to 40th order
Harmonic measurement Harmonic voltage level, harmonic current level, harmonic power level, content per(PW3360-21 only)
centage, phase angle, total harmonic distortion (THD-F or THD-R), up to 40th order
AC adapter Z1006 or Battery pack 9459
Power supply
l Copy function
l Print function
l Report printing
POWER HiTESTER 3333, 3334 / POWER METER PW3335, PW3336, PW3337
Basic specifications
3333 (AC)
3334 (AC/DC)
PW3335 (AC/DC)
PW3336, PW3337 (AC/DC)
Appearance
Measurement line
type
Voltage ranges
Current ranges
Frequency band
Basic accuracy (W)
Single-phase 2-wires, single-phase 3-wires, 3-phase
3-wires, 3-phase 4-wires (PW3337 only)
200 V AC (300 V Max.)
AC/DC 15 V to 300 V, 4 ranges
AC/DC 6 V to 1000 V, 8 ranges
AC/DC 15 V to 1000 V, 7 ranges
50 mA to 20 A AC, 6 ranges (30 A Max.) AC/DC 100 mA to 30.00 A, 6 ranges AC/DC 1 mA to 20 A, 14 ranges (30A max.)
AC/DC 200 mA to 50 A, 8 ranges (65A max.)
45 Hz to 5 kHz
DC, 45 Hz to 5 kHz
DC, 0.1 Hz to 100 kHz
±0.1% rdg. ±0.1% f.s. (45 Hz to 66 Hz)
±0.1% rdg. ±0.05% f.s. (45 Hz to 66 Hz, at Input < 50% f.s.)
Voltage, Current, Active power, Apparent Voltage, Current, Active power, Apparent power, Reactive power, Power factor, Phase angle, Frequency,
Voltage, Current, Active power,
power, Power factor, Frequency,
Efficiency, Current integration, Active power integration, Integrated time, Voltage waveform peak value,
Measurement items Apparent power, Power factor
Integration (current, active power),
Current waveform peak value, Voltage crest factor, Current crest factor, Time average current, Time average
Waveform peak (voltage and current)
active power, Voltage ripple factor, Current ripple factor, harmonic (according to IEC61000-4-7), and other
Key Features/funcAccording to IEC62301, JIS62301
High-current measurement up to 65 A of direct input
Accuracy guaranteed for 1 year/3 years, Analog output
Auto-range integration, and other
Automatically changes the range for each wiring mode, and other
tions
Dimensions and
mass
Model No.
(Order code)
Single-phase/ two-wires
160 mm (6.30 in)W × 100 mm (3.94 in) 210 mm (8.27 in)W × 100 mm (3.94 in) 210 mm (8.27 in)W × 100 mm (3.94 in)H ×
H × 227 mm (8.94 in)D, 1.9 kg (67.0 oz) H × 245 mm (9.65 in)D, 2.5 kg (88.2oz) 245 mm (9.65 in)D, 3 kg (105.8oz)
3333 (basic model)
3333-01 (with GP-IB interface)
3334 (basic model)
3334-01 (with GP-IB interface)
305 mm (12.01 in)W × 132 mm (5.20 in)H × 256 mm
(10.08 in)D, 5.6 kg (197.5 oz)
PW3335 (with LAN, RS-232C)
PW3335-01 (with LAN, GP-IB)
PW3335-02 (with LAN, RS-232C, D/A output)
PW3335-03
(2ch, GP-IB installed model)
PW3335-04
PW3336-03
(with LAN, RS-232C, external current sensor terminal)
(with LAN, RS-232C, GP-IB, D/A output, external current sensor terminal)
PW3336 (2ch model)
PW3336-01
PW3336-02
(2ch, D/A output installed model)
PW3337 (3ch model)
PW3337-01
(3ch, GP-IB installed model)
PW3337-02
(3ch, D/A output installed model)
PW3337-03
(2ch, GP-IB, D/A output installed model) (3ch, GP-IB, D/A output installed model)
7
Data Acquisition / Oscilloscopes
Use for measurement applications like these…
Measuring the voltage waveforms of fuel cell injection systems used in automobiles
Measuring control waveforms for inverter-controlled robots
Testing the charge and discharge characteristics of lithium-ion batteries
Evaluating inverters used in solar power systems
Testing the characteristics (strain, torque, etc.) of machinery (bearings, etc.)
Testing the on-off characteristics of circuit breakers and switches
Measuring the inductive voltage (lightning surge) during lightning strikes
Diagnosing engine deterioration
Testing for fatigue in metal materials (load, displacement, etc.)
Measuring ultrasonic welding waveforms
Diagnosing and measuring deterioration and failure in
combination with an AE sensor
Measuring concrete stress and load
Recording gear eccentricity (X-Y)
Recording pulse rate and electrocardiogram data
Measuring current control signals used by
electric-discharge machining equipment
(recording output from laser Doppler vibrometers)
Advanced Functions
Logic waveform
LOGIC PROBE 9320-01
LOGIC PROBE MRMR9321-01
(9320: large terminal type)
(MR9321: large terminal type)
4ch, For voltage/contact signal ON/OFF detection
Memory Recorder Mode
Logic Input
Recorder Mode
X-Y Input
Instruments feature large capacity semiconductor memory, allowing them to record data
for up to 32 channels (number of channels varies with model) with room to spare.
The input signal is converted to digital form and displayed and printed in real time. The
maximum chart speed is 20 mm/s (in the 500 ms/DIV range). After the end of measurement, measurement data for the last 2000 DIV *1 are still in memory and can be viewed
with the back-scroll function or printed out again.
4 isolated channels, ON/OFF detection of AC/DC voltage
By using logic probe (sold separately), you can record on/off data for relay contact signals, digital signals such as 5 to 24 V signals, and AC relay drive voltages.
Hioki Memory Recorders provide memory for storing X-Y composite waveforms consisting of two digitally converted signals. Waveforms can be observed on the screen in real
time, and there are no limitations on recording time. Waveforms can also be reprinted.
FFT Analysis
FFT capability includes single-signal FFT for analyzing
frequency components, two-signal FFT for transfer
function analysis, and octave analysis for acoustic
analysis. The source signal can be selected from
waveform data captured by the memory recorder, and
isolating required sections is also possible.
(Number of data points: 1,000 to 10,000)
REC & MEM Mode
During the real-time recording of a signal in Recorder mode, when an anomaly is detected by triggers, that portion is stored in memory using the highspeed sampling of
Memory Recorder mode. In the meantime, the Recorder function works independently
and never stops. This function is highly convenient when it is desirable to record both
abnormal phenomena and normal level fluctuations.
X-Y Waveform Display
Hioki memory recorders let you observe X-Y composite waveforms (Lissajous waveforms) that occur
between two signals. Any channel can be set as the
X or Y axis. In addition to its composition capacity
in Memory mode, the instruments can also display real-time images of unlimited recording time
in Recorder mode.
On-site Printouts
RMS Recorder Mode
8
This function is designed exclusively for use on 50/60 Hz power supply lines and DC.
High-speed sampling is applied to calculate the rms value from the waveform data and
the result is recorded as a graph.
A dedicated thermal printer unit allows the instrument to print observed waveforms in the field (the
printer unit is optional for the 8860-50, 8861-50,
MR8880, and MR8827.)
Data Acquisition / Oscilloscopes
Memory HiCorders can not operate alone. You must purchase optional input modules and input cords separately.
MEMORY HiCORDER MR8847A
Generate and record in a single unit
NEW
l Supports a wide variety of measurements with a total of
13 plug-in modules (5 new modules added)
l Generate and record with a single unit
l Direct 1000 V high voltage input testing
l High-speed sampling up to 20MS/s with fully isolated inputs
l 16 analog + 16 logic channels to 64 logic + 10 analog channels
l High-speed sampling with waveform judgement function
l Soil-resistant construction strong against adverse working environments
l Big buttons coated to withstand industrial oil and residue
l Drop-in paper loading and one-touch setup, along with high-speed
50mm/s printing
Model No. (Order Code)
MR8847-51 (MR8847A, 64MW memory, main unit only)
MR8847-52 (MR8847A, 256MW memory, main unit only)
MR8847-53 (MR8847A, 512MW memory, main unit only)
Basic specifications
Input modules
Number of channels
Main unit MR8847-51/ -52/ -53 cannot operate alone.
You must install one or more optional input modules in the unit.
[8 analog input modules]: 16 analog channels + 16 logic channels (standard)
[5 analog input modules + 3 logic input modules]: 10 analog channels + 64 logic channels
5 mV to 20 V/div, 12 ranges, resolution : 1/100 of range (using the 8966)
Measurement ranges
5 mV to 50 V/div, 5 ranges, resolution : 1/1 000 000 of range (using the MR8990)
(20 div full-scale)
200 mV to 50 V/div, 8 ranges, resolution : 1/1600 of range (using the U8794)
400 V DC (using the 8966/8968), 500 V DC (using the MR8990), 1000 V DC (using the U8974)
Max. allowable input
Frequency characteristics (-3dB) DC to 5 MHz (using the 8966), DC (using the MR8990), DC to 100 kHz (using the U8794)
Time axis (Memory function) 5 µs to 5 min/div (100 samples/div) 26 ranges, External sampling (100 samples/div, or free setting)
MR8847-51: Total 64 MW, 32 MW/ch (using 2 Analog channels), to 4 MW/ch (using 16 Analog channels)
MR8847-52: Total 256 MW, 128 MW/ch (using 2 Analog channels), to 16 MW/ch (using 16 Analog channels)
Memory capacity
MR8847-53: Total 512 MW, 256 MW/ch (using 2 Analog channels), to 32 MW/ch (using 16 Analog channels)
MEMORY (high-speed recording), RECORDER (real-time recording), X-Y RECORDER (X-Y real-time recording), FFT
Measurement functions
Waveform judgment (at Memory or FFT function)
Other functions
CF card slot (standard) ×1 (up to 2GB, FAT, or FAT-32 format), SSD (128 GB, optional), USB memory stick (USB 2.0)
Removable storage
216 mm (8.50 in) × 30 m (98.43 ft), thermal paper roll, Recording speed : Max. 50 mm (1.97 in)/s
Printing
[LAN] 100BASE-TX (FTP server, HTTP server), [USB] USB2.0 compliant, series A receptacle ×1, series B
External interfaces
receptacle ×1, (File transfer internal drive/CF card to PC, or remote control from PC)
351 mm (13.82 in) W × 261 mm (10.28 in) H × 140 mm (5.51 in) D, 7.6 kg (268.1 oz) (main unit only)
Dimensions and mass
ANALOG UNIT 8966 (2 ch, Voltage input)
TEMP UNIT 8967 (2 ch, thermocouple temperature input)
HIGH RESOLUTION UNIT 8968 (2 ch, voltage input)
STRAIN UNIT 8969 (2 ch, strain gauge type converter amp)
FREQ UNIT 8970 (2 ch, for frequency)
CURRENT UNIT 8971 (2 ch, for measuring current)
DC/RMS UNIT 8972 (2 ch, Voltage/RMS rectifier)
LOGIC UNIT 8973 (4 terminals, 16 ch)
DIGITAL VOLTMETER UNIT MR8990 (2 ch, DC Voltage input)
HIGH VOLTAGE UNIT U8974 (2ch, voltage input)
Generator modules
ARBITRARY WAVEFORM GENERATOR UNIT U8793 (2 ch)
WAVEFORM GENERATOR UNIT MR8790 (4 ch)
PULSE GENERATOR UNIT MR8791 (8 ch)
MEMORY HiCORDER MR8875
Model No. (Order Code)
MR8875 (Max. 16-60ch, 32MW memory, main unit only)
1000 V Direct Input Multi-channel Logger
l 1000V input and instantaneous DC or RMS waveform measurement
with new Analog Unit MR8905
l Tough against vibrations and extreme temperatures,
with strengthened body ideal for in-vehicle testing and road tests
l 3 different power supplies
l Mixed Measurement of Various Signals,
Install input modules according to your specific needs
l Save directly to the SD Card in real time for uninterrupted long-term logging
Basic specifications
Number of input units
Number of channels
Measurement ranges
(20 div full-scale)
Max. rated voltage
Up to 4 units
Max. 16 analog channels (Max. 60 channels when using the MR8902) + standard 8 logic channels + 2 pulse channels
5 mV to 10 V/div, 11 ranges (when using the MR8901), 500 mV to 50 V/div, 7 ranges (when using the MR8905),
resolution : 1/1250 of range
[Between terminals] 150 V DC, [Between terminal to earth] 100 V AC, DC (when using the MR8901)
Frequency characteristics DC to 100 kHz (-3 dB, when using the MR8901)
200 µs to 5 min/div, 21 ranges, sampling period: 1/100 of range, External sampling possible
Time axis
[Using MR8901] 500 kS/s (2 μs period, all channels simultaneously)
[Using MR8902] 10 ms (all input channels are scanned at high speed during every recording interval)
Max. sampling rate
[Using MR8903] 200 kS/s (5 μs period, all channels simultaneously)
External sampling: 200 kS/s (5 μs period)
Measurement functions High-speed function (high speed recording), Real-time calculation between channels, FFT calculation, or other functions
Removable storage
Communication
interfaces
Power supply
Dimensions and mass
Input modules
Main unit cannot operate alone,
You must install one or more optional input modules in the unit.
(4ch, Voltage measurement) (15ch, Voltage / Thermocouple
measurement)
(4ch, Voltage measurement, Strain gauge converter input)(Up to
15 analog channels each equivalent to a 16-bit analog signal,
and up to 16 logic channels each equivalent to a 1-bit logic signal)
(2ch, High-voltage DC/RMS measurement)
SD card slot ×1, USB 2.0 memory
LAN: 100BASE-TX (DHCP, DNS supported, FTP server/ client, WEB server, send E-mail, command control)
USB: USB 2.0 compliant, series mini-B receptacle ×1 (setting / measure with communication command, or file transfer
SD card to PC), series A receptacle ×2 (USB memory, USB mouse/ key-board)
1) AC adapter Z1002: 100 to 240 V AC (50/60 Hz), 56 VA
2) Battery pack Z1003: 7.2 V DC, 36 VA, continuous operation time: 1 hour with back light ON (AC adapter has priority
when used in combination with battery pack), Charges while installed in the MR8875, recharging time: 3 hours
3) External DC Power: 10 to 28 V DC, 56 VA, (please contact your HIOKI distributor for connection cord)
298 mm (11.73 in)W × 224 mm (8.82 in)H × 84 mm (3.31 in)D, 2.4 kg (84.7 oz), (excluding input units and the Battery pack Z1003)
9
Data Acquisition / Oscilloscopes
Memory HiCorders can not operate alone. You must purchase optional input modules and input cords separately.
MEMORY HiCORDER 8860-50/8861-50
Model No. (Order Code)
8860-50 (main unit only, input modules up to 4 units)
8861-50 (main unit only, input modules up to 8 units)
Logger & Oscilloscope, in a single unit
l The capacity of the memory up to 2GW (8861-50)
l 20 MS/s high-speed sampling (with 8956 Analog Unit)
l Multi-channel logging on up to 64 or 128 channels (with 8958 Scanner Unit)
l Dual-timebase sampling for simultaneous fast and slow monitoring
Input modules
The Memory HiCorder 8860-50 and 8861-50 cannot operate alone.
You must install one or more optional input modules in the unit.
Input modules
8860-50
Basic specifications
8861-50
Max. 16 analog channels (Max. 64 channels when Max. 32 analog channels (Max. 128 channels when
Number of channels
using the 8958) + standard 16 logic channels
using the 8958) + standard 16 logic channels
5 mV to 20 V/div, 12 ranges (when using the 8956), Resolution : 1/100 of range, 20 div f.s.
Measurement ranges
DC 400V (when using the 8956)
Max. allowable input
Frequency characteristics
DC to 10 MHz (-3dB, when using the 8956)
Time axis (MEM)
5 µs to 5 min/div, 26 ranges, sampling period : 1/100 of range, external sampling, dual timebase possible
12-bits × 32M-words/ch (1ch at 8860-50, 2ch at 8861-50) to 2M-words/ch (16ch at 8860-50, 32ch at 8861-50)
Memory capacity
*Memory capacity can be expanded 32 times. (Optional memory board)
Measurement func- MEM (high-speed recording) REC (real-time recording) REC & MEM (realtime recording + highspeed recording) FFT (frequency analysis) Real-time Save (records directly to storage media)
tions
USB 2.0 memory × 3, PC card Type II slot × 2, Hard disk drive (option) × 1
Removable storage
USB 2.0, LAN, Monitor output (15 pin D-sub output), *GP-IB is Not Available
External interfaces
Level/Window/Period/Glitch/Slope/Voltage drop/Event setting/Logic pattern
Trigger types
330 mm (12.99 in) W × 250 mm (9.84 in) H ×
Dimensions and mass 330 mm (12.99 in) W × 250 mm (9.84 in) H ×
284.5 mm (11.20 in) D, 10.5 kg (370.4 oz)
(printer not installed) 184.5 mm (7.26 in) D, 8 kg (282.2 oz)
ANALOG UNIT 8956 (2 ch, Voltage input)
HIGH RESOLUTION UNIT 8957 (2 ch, Voltage input)
16ch SCANNER UNIT 8958 (16 ch, Voltage or Temperature input with thermocouple)
DC/RMS UNIT 8959 (2 ch, Voltage or RMS rectifier)
STRAIN UNIT 8960 (2 ch, Distortion measurement for strain gauge converter)
HIGH VOLTAGE UNIT 8961 (2 ch, Voltage input)
ANALOG UNIT 8936 (2 ch, Voltage input)
VOLTAGE/TEMP UNIT 8937 (2 ch, Voltage or Temperature input with thermocouple)
STRAIN UNIT 8939 (Distortion measurement for strain gauge converter, not CE Marked)
F/V UNIT 8940 (2 ch, Frequency, Voltage input, Current input with clamp-on sensor)
4ch ANALOG UNIT 8946 (4 ch, Low voltage input)
CHARGE UNIT 8947 (2 ch, Charge-output type piezoelectric acceleration pick-up sensor)
Factory-installed options (Must specify when ordering)
Memory boards are not built in as a standard feature. Choose one board for Model 8860-50,
and two of the same capacity for the 8861-50, for factory pre-installation.
MEMORY BOARD 9715-50 (32 Megaword capacity)
MEMORY BOARD 9715-51 (128 Megaword capacity)
MEMORY BOARD 9715-52 (512 Megaword capacity)
MEMORY BOARD 9715-53 (1 Gigaword capacity)
HD UNIT 9718-50 (Built in type, 80 GB)
MEMORY BACKUP UNIT 9719-50
A4 PRINTER UNIT 8995
A6 PRINTER UNIT 8995-01
DC POWER UNIT 9684
PROBE POWER UNIT 9687
MEMORY HiCORDER MR8827
NEW
The next generation of Memory HiCorders that deliver multichannel waveform recording of a diverse array of signals
l 32 analog + 32 logic channels to 28 analog + 64 logic channels
l High-speed sampling up to 20MS/s with fully isolated inputs
l Safe measurement with all isolated analog inputs
l Large capacity memory of total 512M-words
l Measure various system signals from high voltage to ultra low voltage simultaneously
Model No. (Order Code)
MR8827 (Max. 32ch, 512MW memory, main unit only)
Basic specifications
[16 analog input modules]: 32 analog channels +32 logic channels
[14 analog input modules + 2 logic input modules]: 28 analog channels + 64 logic
[Analog unit 8966]: 5 mV/div to 20 V/div, 12 ranges, resolution : 1/100 of range (using 12-bit A/D)
Measurement ranges
[High resolution unit 8968]: 5 mV/div to 20 V/div, 12 ranges, resolution : 1/1600 of range (using 16-bit A/D)
(20 div full-scale)
[Digital voltmeter unit MR8990]: 100 mV f.s. to 1000 V f.s., 5 ranges, resolution : 1/1000,000 of range (using 24-bit A/D)
Max. allowable input 500 V DC (using the MR8990), 400 V DC (using the 8966/8968)
Frequency characteristics DC to 5 MHz (-3 dB, using the 8966), DC to 100 kHz (-3 dB, using the 8968), N/A (using the MR8990)
Number of channels
Time axis (MEM)
Memory capacity
5 µs to 5 min/div, 26 ranges, at 100 points/div resolution
128M-words/ch (using 4 Analog channels) to 16M-words/ch (using 32 Analog channels), Total capacity 512MW memory
Measurement functions Memory (high-speed recording), Recorder (real-time recording), X-Y recorder, FFT
Numerical calculation, Waveform processing, Waveform judgment (at Memory, or FFT function)
Other functions
Input modules
MR8827 cannot operate alone.
You must install one or more optional input modules in the unit.
ANALOG UNIT 8966 (2 ch, Voltage input)
TEMP UNIT 8967 (2 ch, thermocouple temperature input)
HIGH RESOLUTION UNIT 8968 (2 ch, voltage input)
STRAIN UNIT 8969 (2 ch, strain gauge type converter amp)
FREQ UNIT 8970 (2 ch, for frequency)
CURRENT UNIT 8971 (2 ch, for measuring current)
DC/RMS UNIT 8972 (2 ch, Voltage/RMS rectifier)
LOGIC UNIT 8973 (4 terminals, 16 ch)
DIGITAL VOLTMETER UNIT MR8990 (2 ch, DC Voltage input)
HIGH VOLTAGE UNIT U8974 (2ch, voltage input)
Generator modules
Must specify when ordering
Printing
ARBITRARY WAVEFORM GENERATOR UNIT U8793 (2 ch)
WAVEFORM GENERATOR UNIT MR8790 (4 ch)
PULSE GENERATOR UNIT MR8791 (8 ch)
External interfaces
Factory-installed option
Data storage media
USB memory stick, CF card, Built-in SSD unit (option, 128GB)
216 mm (8.50 in) × 30 m (98.43 ft), thermal paper roll, Recording speed : Max. 50 mm (1.97 in)/s
LAN: 100BASE-TX, USB 2.0 series A receptacle 2 port (for USB memory, mouse)
USB 2.0 series B receptacle (for communication to PC, mass storage)
Dimensions and mass 401 mm (15.79 in)W × 233 mm (9.17 in)H × 388 mm (15.28 in)D (including protruding parts except handle)
12.6 kg (444.4 oz)
(main unit only)
10
SSD UNIT U8330 (Built-in type, 128 GB)
PRINTER UNIT U8350
Data Acquisition / Oscilloscopes
Memory HiCorders can not operate alone. You must purchase optional input modules and input cords separately.
MEMORY HiCORDER MR8870
Model No. (Order Code)
Basic specifications
Number of channels
Measurement ranges
MR8870-20 (2ch)
Max. allowable input
2 analog channels + 4 logic channels (standard)
Note: Isolated analog channels, isolated input and frame, logic has common GND
10 mV to 50 V/div (10 div full-scale), 12 ranges, Resolution: 1/100 of range
Between terminals: 400 VDC, Between terminal to earth: 300 VAC, DC CAT II
Frequency characteristics DC to 50 kHz (-3 dB)
100 µs to 5 min/div, 20 ranges,at 100 points/div resolution
Time axis (MEM)
A Single Memory Recorder that can Observe Waveforms like an Oscilloscope and Record RMS Value Fluctuations
l Mode for recording instantaneous waveform and RMS fluctuations
l Save values in real time to a CF card
l Record four channels at once by synchronizing two instruments
with the bundled PC application
l Fast, 1MS/s performance despite the compact size
l Built-in, compact-yet-sharp QVGA-TFT wide LCD
l Compact and easy to carry
l Easy, intuitive operation
MEMORY HiCORDER MR8880
Model No. (Order Code)
MR8880-20 (4ch, printer unit option)
Recording intervals
(RMS)
Measurement functions
Removable storage
Power supply
Dimensions and mass
WAVE PROCESSOR 9335
Model No. (Order Code)
4 analog channels + 8 logic channels (standard)
Note: Isolated analog channels, isolated input and frame, logic has common GND
10 mV to 100 V/div (10 div full-scale), 13 ranges, resolution: 1/640 of range
Measurement ranges
Between terminals: 600 V AC/DC
Max. allowable input
Between terminal to earth: 600 V AC/DC CAT III; 300 V AC/DC CAT IV
Frequency characteristics DC to 100 kHz (±3dB)
High-speed: 100 µs to 100 ms/div, 10 ranges, Sampling period: 1/100 of range
Time axis
Power supply
Dimensions and mass
Basic specifications
Operating environment
Display functions
9335
File loading
Data conversion
Other
Display, Convert, Calculate,
and Print Waveforms with a PC
CF card TYPE I slot ×1 (Up to 2 GB)
[AC Adapter Z1005] 100 to 240 VAC (50/60 Hz) , 30 VA max.
(when using the AC adapter and charging the 9780 with the instrument)
[Battery Pack 9780] 3 VA, continuous operating time of approx. 2 hr.
(25°C reference value; when used with the Z1005, the Z1005 takes priority),
charging time of 200 min. using the AC adapter (25°C reference value) (option)
[External DC power] 10 to 16 V, 10 VA max.
(connection cord of 3 m or less is available by special-order)
176 mm (6.93 in)W × 101 mm (3.98 in)H × 41 mm (1.61 in)D, 600 g (21.2 oz)
(with the Battery pack 9780 installed)
Number of channels
Removable storage
l CAT III 600V isolation performance; directly measure a 480V power line
l 4 completely isolated channels let you simultaneously record data
on a 3-phase power line plus have one extra channel
l Tough against harsh environments; -10°C to 50°C operating temperature range
l Built to withstand mechanical shocks and vibrations
(ships standard with side protectors)
l Make settings easily with PRESETS function
Memory recorder (high speed recording), RMS recorder (50/60 Hz, DC only)
Basic specifications
Recording intervals
(Real-time function)
Measurement functions
Capture high- to low-voltage
signals in a single device
1 ms to 1 min., 16 settings, sampling period: 200 μs (fixed)
Print functions
100 µs to 1 minute, 19 selections (simultaneous sampling in all channels)
High-speed function, Real-time function (actual time recording)
CF card slot ×1 (Up to 2 GB), USB 2.0 memory ×1
[AC adapter Z1002] 100 to 240 V AC (50/60 Hz), 45 VA (include AC adapter,
when Real-time recording), 107 VA (include AC adapter, when Real-time recording and printing)
[Battery pack Z1000] AC adapter has priority when used in combination with battery
pack, recharge with AC adapter 3 hours, Continuous use 3 hours (with back-light ON)
[LR6 (AA) alkaline batteries] ×8, Continuous use 40 minutes,
(with back-light ON, cannot be used with the Printer unit)
[DC power supply] 10 to 28 V DC (cable available by special order)
205 mm (8.07 in)W × 199 mm (7.83 in)H × 67 mm (2.64 in)D, 1.66 kg (58.6 oz)
(with the Battery pack installed)
Computer running under Windows 10/8/7 (32/64-bit), Vista (32-bit), XP
Waveform display, X-Y display, Digital value display, Cursor function, Scroll
function, Maximum number of channels (32 channels analog, 32 channels
logic), Gauge display (time, voltage axes), Graphical display
Readable data formats (.MEM, .REC, .RMS, .POW),
Maximum loadable file size: Maximum file size that can be saved by a given
device (file size may be limited depending on the computer configuration)
Conversion to CSV format, Tab delimited, Space delimited, Data culling
(simple), Convert for specified channel, Batch conversion of multiple files
Parameter calculation, Search, Clipboard copy, Launching of other applications
Printing image file output (expanded META type, ".EMF"),
Supported printer: usable on any printer supported by operating system
Print formatting: (1 up, 2-to-16 up, 2-to-16 rows, X-Y 1-to-4 up, preview, hard copy
Depending on the version of 9335,there is a model that can not be used. Please check the specifications of the Memory Hicorder.
l Display waveform screens, X-Y graphs, and numerical results
l Rich printing and hard copy functions to assist in creating reports
l Save in CSV format and export to spreadsheet application (EXCEL)
iPad App for Memory HiCorder
HMR Terminal
Outline specifications
Supported models
Operating environment
Functions
Analyze Memory
HiCorder waveforms right on your iPad
l Free app (exclusively for iPad) downloadable from the App Store
l iPad-unique gestures let you analyze measurement data any way you like
l Multi-channel support - up to 32 channels of waveform data at your fingertips
MR8740, MR8741, MR8847-01/-02/-03, MR8847-51/-52/-53, MR8827, 8847
* calculated waveforms and logical waveforms not supported
iOS on the iPad (Apple Inc. )
• Data acquisition: Send to iPad via FTP using a WiFi router, or load to iPad via
iTunes (PC app)
• Intuitively operate waveform level searches, maximum / minimum / average
values, zero position adjustment, and more at your fingertips
• Waveform monitoring
• Meter setting
* Logic waveforms and computational waveforms are not supported.
Data can be viewed by the iPad using Hioki’s dedicated apps available from the App
Store. Search for “HIOKI” and download the “HMR Terminal” app.
*iOS is a registered trademark of Cisco Technology, Inc. and/or its affiliates in the United States and certain other countries.
*iPhone, iPad, iPad mini, iPad Pro and iPod touch are trademarks of Apple Inc.
*Apple and the Apple logo are trademarks of Apple Inc. App Store is a service mark of Apple Inc.
11
Data Loggers
Battery pack is sold separately
Countries where wireless use is supported: Japan, the USA, Canada, the EU, and other licensed countries
For an updated list of supported countries and regions, please visit www.hioki.com.
Use for measurement applications like these…
Measuring variations in body temperature caused by water pressure (while installed in a wetsuit)
Measuring temperature distribution in electromagnetic cooking appliances
Measuring the charging and discharging of batteries
Measuring heat island phenomena
Measuring the temperature of solar panels
Measuring the temperature distribution in clothing and bedding
Capturing a range of data at wind power installations
Measuring the temperature distribution in seawater
Measuring temperature in agricultural greenhouses
Measuring temperature in geothermal power generation
Measuring environmental conditions in living spaces
Measuring the temperature distribution in forests and soil
Model No. (Order Code) LR8410-20
WIRELESS LOGGING STATION LR8410
Logging Multi-point Data Has Never Been
So Easy with a Wireless Logger
(English model, main unit only)
The LR8410-20 alone is not capable of making measurements. One or more input modules are necessary to measure.
LR8410-20 alone is not capable of making measurements. One or more input modules are necessary to measure.
Basic specifications (LR8410)
Number of chan- Connect up to seven LR8510 series units wirelessly (using Bluetooth®
wireless technology) to measure or collect data from up to 105 channels.
nels
100 ms(*), 200 ms to 1 hour, 16 selections (All input channels are
Recording
scanned within each recording interval.) (*) Setting not available when
intervals
the thermocouple burnout detection setting is on
Internal memory: 8 M-words, Data storage media: SD memory card
or USB memory stick (Only data recorded to a genuine HIOKI SD
Data storage
memory card is guaranteed)
Save waveform data in real time to the SD memory card or USB
memory stick, Numerical value calculations, Waveform calculations,
Functions
4ch alarm output (not isolated, common ground), and others
LAN: 100BASE-TX, USB 2.0 series mini-B receptacle ×1
Interface
[AC adapter] Using the AC adapter Z1008 (100 to 240 V AC, 50/60 Hz),
45 VA Max. (including AC adapter), 15 VA Max. (exclusive of AC adapter)
[Internal battery] Using the Battery pack Z1007 (optional accessory), 3
Power supply
hours of continuous use (at 23 ˚C reference data), 7 VA Max.
[External power] 10 to 28 V DC, 15 VA Max. (Please contact your
HIOKI distributor for connection cord)
Dimensions and 230 mm (9.06 in) W × 125 mm (4.92 in) H × 36 mm (1.42 in) D, 700 g
(24.7 oz) (excluding Battery pack)
mass
Model No. (Order Code)
LR8423
(main unit only)
l Capture logging data using Bluetooth® wireless technology. Install logging
modules in hard-to-reach locations (over line-of-sight distances of up to 30
meters *1 ) (*1) The presence of obstructions may shorten this range
l Choose an input unit based on the parameters you wish to measure
(LR8410/LR8415: 15-channel, Wireless mini logger series: 1 or 2-channel)
l Easily add up to 7 input units wirelessly to keep your environment free of
tangled wires (for a total of up to 105 channels when using 15-channel units)
l Quick Set guide makes configuration a breeze
Basic specifications (LR8510/LR8511)
15 analog channels; isolated scanning method input (4 terminals: push-button type)
[Voltage] ±10 mV to ±100 V, 1-5 V f.s., max. 500 nV resolution
[Temperature: Thermocouples] -200 ˚C to 2000 ˚C (depends on sensor),
WIRELESS UNIVER- Thermocouples (K, J, T, or other), max. 0.01 ˚C resolution
[Temperature: Pt 100, JPt 100 sensor] -200 ˚C to 800 ˚C, max. 0.01 ˚C resoluSAL UNIT
tion (not isolated between channels)
LR8511
[Resistance] 0 Ω to 200 Ω f.s., max. 0.5 mΩ resolution (not isolated between channels)
[Humidity] 5.0 to 95.0 % rh (use with optional sensor), 0.1 % rh resolution
(not isolated between channels)
15 analog channels; isolated scanning method input (2 terminals: M3 screw type)
WIRELESS VOLT[Voltage] ±10 mV to ±100 V, 1-5 V f.s., max. 500 nV resolution
AGE/TEMP UNIT
[Temperature: Thermocouples] -200 ˚C to 2000 ˚C (depends on sensor),
LR8510
Thermocouples (K, J, T, or other), max. 0.01 ˚C resolution
300 V AC, DC
Max. rated voltage from
isolated terminals to ground (max. voltage from terminals to chassis ground without damage)
[AC adapter] Using the AC adapter Z1008 (100 to 240 V AC, 50/60 Hz), 23
VA Max. (including AC adapter), 7 VA Max. (exclusive of AC adapter)
[Internal battery] Using the Battery Pack Z1007 (optional accessory), 24 hours of
Power supply
continuous use (at 100 ms recording interval, 23 ˚C reference data), 120 hours of
continuous use (at 1 minute recording interval, 23 ˚C reference data), 0.4 VA Max.
[External power] 10 to 28 V DC, 7 VA Max.
Dimensions and mass 150 mm (5.91 in) W × 90 mm (3.54 in) H × 56 mm (2.20 in) D, 340 g (12.0 oz)
MEMORY HiLOGGER 8423
600-channel Data Logger with 10ms Sampling
l Capture data with 15 to a maximum of 600 channels
l Send data to the PC in real time
l Isolated to sustain up to 600 V between modules and earth
l USB 2.0, LAN 100BASE-TX, store to 1GB PC Card
l Simultaneous fast- and low-speed sampling allows for media storage space efficiency
Basic specifications
No. of connectable units Max. 8 units (total 120 channels), Bundle 8 modules together to achieve a 120-ch system, Bundle 5 systems together to enable a maximum of 600 channels of simultaneous recording
[No. of channels] 15 analog channels, isolated scanning method input (2 terminals: M3 screw type)
Measurement param[Voltage measurement range] ±150 mV to ±100 V, 1-5V, Max. resolution 5 µV, Max. allowable input: 100 VDC, between channels: 200 VDC, to earth: 600 VAC/DC
eters Model 8948
[Temperature range] -200˚C to 2000˚C (depend on the sensor), thermocouples (K, J, E, T, N, R, S, B, W), Max. resolution 0.01˚C
[No. of channels] 15 analog channels, isolated scanning method input (4 terminals: push-button type) (not isolated between channels at resistance temperature sensor & humidity sensor)
[Voltage measurement range] ±150 mV to ±60 V, 1-5V, Max. resolution 5 µV, Max. allowable input: 60 VDC, between channels: 120 VDC, to earth: 600 VAC/DC
Measurement param[Temperature range] -200˚C to 2000˚C (depend on the sensor), thermocouples (K, J, E, T, N, R, S, B, W), Max. resolution 0.01˚C
eters Model 8949
[Resistance temperature sensor range] -200˚C to 800˚C, (Pt 100, JPt 100), Max. resolution 0.01˚C [Humidity] 5.0 to 95.0% rh, (use with optional sensor), resolution 0.1% rh
[No. of channels] 15 channels, digital/pulse input (2 terminals: M3 screw type, CH1-5, CH6-10, CH11-15 are common GND, No-voltage ‘a’ contact, open collector or voltage input)
[Totalized pulses] 0 to 1000M pulse, Max. resolution 1 pulse [Rotation count] 0 to 5000/n (r/s), Resolution 1/n (r/s) *n = pulses per rotation (1 to 1,000)
Measurement param[Digital input] Record ON/OFF digital signal per interval [Max. allowable input] 50 VDC, between channels: 33 VACrms or 70 VDC, to earth: 600 VAC/DC, (Upper limit
eters Model 8996
voltage that does not cause damage when applied between CH1-5, CH6-10, CH11-15 each channel and chassis, and between each UNITs)
10 ms to 1 hr, 19 ranges (5s to 1hr when combined with humidity measurement), Dual sampling: Recording intervals can be specified for every input module (high-speed and low-speed)
Recording intervals
Measurement data are saved to the CF Card in real time, Trigger function, Digital filter (Input unit), Alarm output (use with the Alarm unit 8997), Data acquisiFunction
tion is controlled by the PC data acquisition program, FTP server function, HTTP server function
Using the AC adapter 9418-15 (100 to 240 V, 50/60 Hz), 55 VA Max. (include AC adapter), 20 VA Max. (main unit only) (when connected with 8 units),
Power supply
External DC Power: 9.6 V to 15.6 VDC, 20 VA Max. (when connected with 8 units) (Please contact HIOKI for connection cord)
Dimensions and mass 67 mm (2.64 in) W × 133 mm (5.24 in) H × 125 mm (4.92 in) D, 600 g (21.2 oz) (main unit 8423 only)
12
Data Loggers
Battery pack is sold separately
MEMORY HiLOGGER LR8400 Series
Portable Handheld 30- to 60- channel Data Loggers
with 10ms Simultaneous Sampling
l Compact size despite 30-channel standard capabilities
l Write data to USB memory stick or CF card in real-time
l Expand up to 30 additional channels
l Protected against unexpected power outages
l Built in with USB 2.0 or 100 BASE-TX LAN interfaces
l 5.7" TFT color display
Model No. (Order Code)
LR8400-20 (Voltage/temp unit LR8500 ×2, 30 ch, English model)
LR8401-20 (Universal unit LR8501 ×2, 30 ch, English model)
LR8402-20 (Universal unit ×1, Voltage/temp unit ×1, 30 ch, English model)
Built-in units cannot be removed or changed
Basic specifications
Analog input Universal unit LR8501 Actual functionality will depend on combination of units installed
Note: Isolated from each channel to chassis
Number of channels
15 analog channels; isolated scanning method input (4 terminals: push-button type)
±10 mV to ±100 V, 1-5 V f.s. Max. resolution: 500 nV, (Isolated between channels and from each channel to chassis)
Voltage
Temperature: Thermocouples -200 ˚C to 2000 ˚C (depends on sensor), Thermocouples (K, J, E, T, N, R, S, B, W,) Max. resolution 0.01 ˚C, (Isolated between channels and from each channel to chassis)
Temperature: Pt 100, JPt 100 sensor -200 ˚C to 800 ˚C, Max. resolution 0.01 ˚C (Not isolated between channels)
0 Ω to 200 Ω f.s. Max. resolution 0.5 mΩ (Not isolated between channels)
Resistance
5.0 to 95.0 % rh (use with optional sensor), resolution 0.1 % rh, (Not isolated between channels nor from each channel to chassis)
Humidity
[Max. rated voltage between isolated input channels] 300 V DC, [Max. allowable input] ±100 V DC, [Max. rated voltage from isolated terminals to ground] 300 V AC, DC
Other
Analog input Votage/temp unit LR8500 Actual functionality will depend on combination of units installed
Note: Isolated from each channel to chassis
Number of channels
15 analog channels; isolated scanning method input (2 terminals: M3 screw type)
±10 mV to ±100 V, 1-5 V f.s. Max. resolution: 500 nV, (Isolated between channels and from each channel to chassies)
Voltage
Temperature: Thermocouples -200 ˚C to 2000 ˚C (depends on sensor), Thermocouples (K, J, E, T, N, R, S, B, W), Max. resolution 0.01 ˚C, (Isolated between channels and from each channel to chassies)
5.0 to 95.0 % rh (use with optional sensor), resolution 0.1 % rh, (Not isolated between channels nor from each channel to chassies)
Humidity
[Max. rated voltage between isolated input channels] 300 V DC, [Max. allowable input] ±100 V DC, [Max. rated voltage from isolated terminals to ground] 300 V AC, DC
Other
Common specifications
Pulse, Digital input
Power supply
Dimensions and Mass
[No. of channels] 8 channels, pulse / digital selectable for each channel, M3 screw terminal, not isolated, common ground
[Pulse totalization] 0 to 1000 M pulse, 1 range (No-voltage 'a' contact; normally open, open collector or voltage input), Max. resolution 1 pulse
[Rotation count] 0 to 5000 /n (r/s) f.s. 1 range (same as Pulse totalization input signal condition), resolution 1/n (r/s) Note: "n" is the number of sensor output pulses per revolution, 1 to 1000
[Digital input] Record logical "1" or "0" at each sampling, [Max. rated voltage between input channels] Not isolated, [Max. allowable input] 0 to 50 V
[AC adapter] 9418-15 (100 to 240 V AC, 50/60 Hz), 7 VA [Battery pack] Z1000 (optional accessory), Continuous use 5 hr
[External power] 10 to 28 V DC (Please contact your HIOKI distributor for connection cord)
272 mm (10.71 in) W × 182.4 mm (7.18 in) H × 66.5 mm (2.62 in) D, 1.8 kg (63.5 oz), (LR8400-20 main unit, excluding the Battery Pack 370 g/ 13.1 oz)
MEMORY HiLOGGER LR8431
Model No. (Order Code) LR8431-20
(10ch, English model)
Portable Handheld
10-isolated channel Data Logger
with 10ms Simultaneous Sampling
l Record measurement data on a USB flash drive for easy
transfer to a computer
l Improved thermocouple measurement accuracy and
reference junction compensation accuracy
l Replace storage media during real-time recording
l Noise-resistant measurement circuitry for improved readings
HEAT FLOW LOGGER LR8432
Model No. (Order Code) LR8432-20
(English model)
Basic specifications
[Analog] 10 isolated channels using scanning input method (M3 mm dia. screw terminal block)
Number of channels
[Pulse] 4 channels (All pulse inputs share common ground with the main unit)
[Voltage] ±100 mV to ±60 V, 1-5V f.s. 6 ranges, Max. resolution 5µV
[Temperature (thermocouples)] -200 ˚C to 1800 ˚C (depend on the sensor) 1 range (K, J,
E, T, N, R, S, B), Max. resolution 0.1 ˚C
Measurement
[Totalized pulses] 0 to 1000M pulse, 1 range (No-voltage ‘a’ contact, open collector or
range
voltage input), Max. resolution 1 pulse
[Rotation count] 0 to 5000/n (r/s) f.s. 1 range (No-voltage ‘a’ contact, open collector or
voltage input), Resolution 1/n (r/s) Note: n = pulses per rotation (1 to 1,000)
Recording intervals 10 ms to 1 hour, 19 selections (All input channels are scanned within each recording interval)
Save data to the CF card or USB memory stick in real time, Numerical Calculations, etc.
Functions
External interface USB 2.0 mini-B receptacle ×1
[AC adapter] Z1005, 100 to 240 VAC (50/60 Hz)
[Battery pack] 9780, Continuous use 2.5 hours
Power supply
[12 V DC supply] 10 to 16 V (please contact HIOKI distributor for cable
176 mm (6.93 in) W × 101 mm (3.98 in) H × 41 mm (1.61 in) D, 550 g (19.4 oz)
Dimensions and
(Battery pack 9780 not installed)
mass
Basic specifications
coefficient), Integration with numerical calculations
Voltage measurement
range
Other
Compact & Lightweight
Heat Flow Logger for Analyzing
the Causes of Temperature Change
l Use a heat flow sensor to measure the movement
and volume of heat energy
l Easily analyze temperature and heat flow
l Replace storage media during real-time recording
[Easy scaling settings] directly enter the sensitivity of the heat flow sensor
Specialized functions for [Calculations] waveform processing function for the analysis of temperature
heat flow measurement and heat flow (Simple average, moving average, integration, heat transmission
±10 mV to ±60 V, 1-5V, Max. resolution 500 nV
Basic specifications are the same as the model LR8431
Heat flow sensor (option)
Measurement of small parts
54.1 mm
Cord length: 1.5 m (4.92 ft)
Select from
and curved surfaces of piping
(2.13 in)
Waterproof characteristics : IP06, IP07
Model Z2012
M Model Z2013
L Model Z2014
3 sizes
31.6 mm
(1.24 in)
9.1 mm
(0.36 in)
Small parts
Curved surfaces
S size
M size
L size
Cord length: 5 m (16.40 ft)
S Model Z2015
M Model Z2016
L Model Z2017
13
Data Loggers
Countries where wireless use is supported: Japan, the USA, Canada, the EU, and other licensed countries
For an updated list of supported countries and regions, please visit www.hioki.com.
WIRELESS MINI LOGGER series
Easy, wireless collection
of a variety of data types
n Data can be downloaded using Hioki’s tablet and smartphone app (for Android devices).
Search for “HIOKI” and download the Wireless Logger Collector!
Android Terminal
l Connect to a tablet, smartphone, or PC
for easy, wireless data collection
l Instrument can store 500,000 data points
per channel
• Use your Android terminal to set
and send measurement conditions,
such as the recording interval, to the
logger to begin measurement.
• Collect the data recorded in the logger after or even during measurement.
(Collection software acquisition:
Download from Google Play)
wireless technology
Model No. (Order Code)
WIRELESS
CLAMP LOGGER
LR8513
Data analysis
Start "Logger Utility" and perform analysis at the
touch of a button.
USB
• Connect a USB cable to transfer
the data to a PC. Use the bundled
software, "Logger Utility," to
perform analysis.
WIRELESS
PULSE LOGGER
LR8512
Setting, Measurement, Data collection
Use your Windows PC to set and send measurement conditions, such as the recording interval, to
the logger to begin measurement.Collect the data
recorded in the logger after or even during measurement.
Data analysis
Basic specifications
Windows PC
Setting, Measurement, Data collection
wireless technology
WIRELESS
HUMIDITY LOGGER
LR8514
WIRELESS
VOLTAGE/ TEMP LOGGER
LR8515
2 ch for temperature +
2 ch for humidity
(2 sensors can be attached)
2 channels
WIRELESS
FUNGAL LOGGER
LR8520
Physical
appearance
Current and leak current that occur
intermittently cannot be measured.
1 ch for temperature +
1 ch for humidity
(1 sensors can be attached)
AC load current, DC load
Fungal index,
Pulse, no. of revolutions,
Temperature
Voltage
current, AC leak current
Growth prediction,
Measurement items
logic
Humidity
Thermocouple
(K,
T)
(using current sensor)
Temperature, Humidity
Temperature: -40 ˚C to 80 ˚C
Pulse: 0 to 1000M pulse
AC: 500.0 mA to 2000 A
Voltage:
-50
V
to
50
V
Temperature: -40 ˚C to 80 ˚C Thermocouple (K): -200˚C to 999.9˚C
Humidity: 0% rh to 100% rh
Measurement
No. of revolutions:
DC: 10.00 A to 2000 A
Humidity: 0% rh to 100% rh Thermocouple
fungal index from
range
0 to 5000/n [r/s]
(using current sensor)
(T): -200˚C to 400˚C (Calculates
temperature and humidity.)
±0.5% rdg.±5 dgt.
Temperature: ±0.5 ˚C
Voltage: ±0.05 mV
Temperature: ±0.5 ˚C
Basic accuracy
(DC, AC 50 Hz/60 Hz)
Humidity: ±3% rh
Thermocouple : ±0.6 ˚C
Humidity: ±3% rh
85W×75H×38D mm (3.35W× 85W×61H×31D mm (3.35W×
85W×75H×38D mm (3.35W×
85W×61H×31D mm (3.35W×
Dimensions and mass 85W×61H×31D mm (3.35W×
(Not including the battery) 2.40H×1.22D in), 95 g (3.4 oz) 2.95H×1.50D in), 130 g (4.6 oz) 2.40H×1.22D in), 95 g (3.4 oz) 2.95H×1.50D in), 126 g (4.4 oz)
2.40H×1.22D in), 95 g (3.4 oz)
CONNECTION CABLE
Clamp sensor is sold sepaHumidity sensor is sold
Humidity sensor is sold separately
Thermocouples
sold
separately
Other
L1010 is bundled
rately
separately
Includes output function
Number of
channels
2 channels (common GND)
2 channels (common GND)
Compact Data Logger LR5000 Series
Various Compact Data Loggers
Transfer Data from a LR5000 Series Data Logger to a PC
Communication Adapter LR5091 or Data Collector LR5092-20 is necessary to transfer data from a LR5000 series Logger to a PC.
l Easily mount the light-weight , pocket-sized loggers
in tight spaces
l Measurement data is preserved even after the battery dies
l Record large amounts of data by a simple operation
l Bring the data logger LR5000 series back from the field and transfer data to a PC
l Use the included software to easily graph and print data
COMMUNICATION
ADAPTER LR5091
Model No. (Order Code) LR5091
USB cable is bundled
Analysis of measurement data on a PC requires the optional
Communication Adapter LR5091 or Data Collector LR5092-20.
Basic specifications
HUMIDITY LOGGER
TEMPERATURE LOGGER
Model No. (Order Code)
LR5001
LR5011
INSTRUMENTATION
LOGGER
LR5031
Temperature 1ch and
humidity 1ch
Temperature 1ch
Temperature : -40°C to 85°C
Humidity : 0% to 100%rh
-40.0˚C to 180˚C
*Depends on measurement
range of sensor.
Basic accuracy
Temperature : ±0.5°C (at 0°C to 35°C )
Humidity : ±5%rh (at 50%rh or less, 25°C)
±0.5˚C (at 0˚C to 35˚C )
Other
HUMIDITY SENSOR LR9504 is bundled
Sensor is sold separately
Measurement range
14
Model No. (Order Code) LR5091-20
Save data from data loggers in the
built-in memory or on an SD card
USB cable is bundled
SD memory card sold separately.
CLAMP LOGGER
VOLTAGE LOGGER
LR5051
LR5041, LR5042, LR5043
Current and
leak current
that occur
intermittently
cannot be
measured.
Physical
appearance
Measurement items
DATA COLLECTOR LR5092
Instrumentation 1ch
-30.00 to 30.00mA DC
AC current (2 channels)
DC voltage 1ch
0.00 to 1000 A AC
LR5041: -50.00 mV to 50.00 mV
LR5042: -5.000 V to 5.000 V
LR5043: -50.00 V to 50.00 V
±2.0%rdg. ±0.13% f.s.
(at Main unit+ CT6500, 500.0 A
range, 50/60 Hz typical value)
Connection cable is bundled Clamp sensor is sold separately
±0.5%rdg. ±5dgt.
(at 23˚C±5˚C)
±0.5%rdg. ±5dgt. (at
23°C±5°C)
Connection cable is bundled
Resistance Meters / Battery Testers
Depending on the model, please select and purchase the measurement probe options appropriate for your application separately.
Use for measurement applications like these…
Performing basic experiments using electric circuits
Evaluating thermoelectric element materials
Generating Cole-Cole plots for lithium-ion batteries
Evaluating circuit board continuity and insulation
resistance
Measuring the resistance of materials such as pure iron and enamel wires
Measuring the resistance of magnetic heads (using the low-power resistance measurement function)
Measuring the resistance of coils, transformers, relays,
switches, and printed circuit boards
Evaluating the internal resistance of batteries
and electrical double layer capacitors
BATTERY IMPEDANCE METER BT4560
Model No. (Order Code) BT4560
Variable frequency
High-speed measurement
l Bundled with free PC application that can be used for measurement and
drawing Cole-Cole plots.
l Extremely reliable measurements for low-impedance batteries
*The BT4560 uses a testing current of 1.5 A at the 3mΩ range, which improves the S/N ratio
l Circuit configuration highly tolerant of contact and wire resistance to
provide stable measurements
l Simultaneous measurement of impedance and voltage
RESISTANCE METER RM3545
Model No. (Order Code) RM3545
RM3545-01 (with GP-IB interface)
RM3545-02 (support for the multiplexer unit)
Featuring super-high accuracy
and multi-channel capabilities
Basic specifications
Allowable input voltage Up to 5 V
Measured signals Impedance, voltage, temperature
[Parameters] R, X, Z, θ, Frequency: 0.1 Hz to 1050 Hz
[Measurement ranges] 3.0000 mΩ, 10.0000 mΩ, 100.000 mΩ
[Testing current] 3 mΩ range: 1.5 Arms, 10 mΩ range: 500 mArms, 100 mΩ range: 50 mArms
Voltage measurement Measurement range: 5.00000 V (single range), Measurement time: 0.1 s (Fast) to 1.0 s (Slow)
Temperature measurement Range: -10.0 °C to 60.0 °C, Measurement time: 2.3 s
Basic accuracy
Z: ±0.4% rdg. θ: ±0.1°, V: ±0.0035% rdg. ±5 dgt., Temperature: ±0.5 °C (at 10.0 to 40.0 °C)
Comparator, self-calibration, sample delay, average, contact check, measurement
Functions
current error, and other
RS-232C/USB (virtual COM port) * Cannot be used simultaneously, EXT. I/O
Interfaces
Impedance
measurement
(NPN/PNP can be switched)
Power supply
100 to 240 V AC, 50/60 Hz, 80 VA max
Dimensions and mass 330 mm (12.99 in) W × 80 mm (3.15 in) H × 293 mm (11.54 in) D, 3.7 kg (130.5 oz)
This product is not supplied with measurement probes.
Please select and purchase the measurement probe options appropriate for your application separately.
Basic specifications
Resistance range
Testing current
Open-terminal
voltage
Temperature measurement
(20 channels with 4-terminal measurement)
Functions
l 0.006% basic accuracy, 0.01 μΩ max. resolution, 1A max. testing current
l Measure from 0.00 μΩ (testing current 1 A) to 1200 MΩ
l Multiplexer Unit Z3003 (option) provides 20-channels of 4-terminal measurements for a complete assessment of multi-point signals (RM3545-02 only)
l Low-power resistance measurement with an open voltage not exceeding 20 mV
Communication
interfaces
Power supply
Dimensions and
mass
BATTERY HiTESTER BT3563, BT3562
Model No. (Order Code)
BT3562, BT3563 (basic model)
BT3562-01, BT3563-01 (with GP-IB interface)
High-speed evaluation of
Large-cell to High-voltage
Batteries
10 mΩ to 1000 MΩ range , 12 steps, Measurement accuracy: ±0.006 % rdg. ±0.001 % f.s.
1 A DC to 1 µA or less [LP ON] 1 mA to 5 μA DC
20 V DC (10 kΩ range or more), 5.5 V DC max. (1000 Ω range or less)
[LP ON] 20 mV DC max.
-10.0 to 99.9 °C, accuracy: ±0.50 °C (Temperature Sensor Z2001 and RM3545
combined accuracy), -99.9 to 999.9°C (analog input)
Temperature correction, temperature conversion, offset voltage compensation
(OVC), comparator (ABS/ REF%), BIN, key-lock (OFF, menu lock, all lock), display digit count selection function (7- digit/ 6-digit/ 5-digit), automatic power supply frequency settings (AUTO/ 50Hz/ 60Hz), scaling, judgment sound setting,
auto hold, averaging, statistical calculations, panel store/panel load, D/A output.
Select from GP-IB (RM3545-01 only), RS-232C, PRINTER (RS-232C), or USB .
Remote function, communications monitor function, data output function, memory (50)
100 to 240 V AC, 50/60 Hz, Rated power consumption: 40 VA
215 mm (8.46 in) W × 80 mm (3.15 in) H × 306.5 mm (12.07 in) D
[RM3545/RM3545-01] 2.5 kg (88.2 oz), [RM3545-02] 3.2 kg (35.3 oz)
Basic specifications
Measurement
ranges
Basic accuracy
(SLOW)
Response time
Interfaces
Power supply
Dimensions and mass
[Resistance] 3 mΩ to 3000 Ω , 7 ranges
[Voltage] 6 VDC to 300 VDC , 3 ranges (300 V range: BT3563 only)
[Ω] ±0.5% rdg.±5 dgt., [V] ±0.01% rdg.±3 dgt.
approx. 10 ms (Response time depends on reference values and the measurement object.)
External I/O, RS-232C, Printer (RS-232C), GP-IB (-01 suffix models only)
100 to 240 VAC, 50/60 Hz, 30 VA max.
215 mm (8.46 in) W × 80 mm (3.15 in) H × 295 mm (11.61 in) D, 2.4 kg (84.7 oz)
l Measure high-voltage battery packs up to 300V (BT3563)
l Evaluate lithium-ion storage batteries, nickel-metal-hydride
storage batteries, and lead-acid storage batteries.
l Evaluate fuel cell stacks.
DC SIGNAL SOURCE SS7012
Model No. (Order Code) SS7012
Generate and Measure
Signals Simultaneously
l Simultaneously sources up to ±25 V and ±25 mA
while measuring up to ±28 V and ±28 mA (DC)
l Generate and measure ±25 V, ±25 mA output with a single instrument
l Evaluate circuit characteristics and test the characteristics of semiconductors
l Fully controllable via its USB interface.
l Use in schools as a portable signal source for electronic device testing
and evaluation.
Use of the AC Adapter and /or rechargeable batteries and dedicated charger is recommended.
Basic specifications
Generation functions
2.5 V: 0 to ±2.5000 V (±0.03 % of setting ±300 μV, 100 μV resolution)
25 V: 0 to ±25.000 V (±0.03 % of setting ±3 mV, 1 mV resolution)
Constant Current 25 mA: 0 to ±25.000 mA (±0.03 % of setting ±3 μA, 1 μA resolution)
K: at TC: 0 ˚C, -174.0 to 1372.0 ˚C (±0.05 % of setting ±0.5 ˚C, 0.1 ˚C resolution)
Thermoelectric
power generation Other types: E, J, T, R, S, B, N selectable
K: at TC: RJ, -174.0 to 1372.0 ˚C (±0.05 % of setting ±1.0 ˚C, 0.1 ˚C resolution)
Thermoelectric
power generation Other types: E, J, T, R, S, B, N selectable
Standard resistance (Rs) 100 Ω (±0.2 Ω)
Constant Voltage
Measurement functions
2.5 V: 0 to ±2.8000 V (±0.03 % rdg. ±300 μV, 100 μV resolution, 1 MΩ input resistance)
25 V: 0 to ±28.000 V (±0.03 % rdg. ±3 mV, 1 mV resolution, 1 MΩ input resistance)
25 mA: 0 to ±28.000 mA (±0.03 % rdg. ±3 μA, 1 μA resolution, 25 Ω input resistance)
Current
-25.0 to 80.0 ˚C (±0.5 ˚C at 23 ±5 ˚C, 0.1 ˚C resolution, use with the RJ sensor 9184)
Temperature
AC adapter 9445-02/03 (100 to 240 V AC 50/60 Hz, 9 VA),
Ni-MH battery HR6 × 4, 6 VA, (fully charged 2500 mAh Ni-MH batteries: 170
Power supply
minutes continuous use), or LR6 (AA) alkaline battery × 4, 6 VA
104 mm (4.09 in)W × 180 mm (7.09 in)H × 58 mm (2.28 in)D, 660 g (23.3 oz)
Dimensions and mass
(including LR6 × 4 batteries)
Voltage
15
Electrometers / Picoammeters
Depending on the model, please select and purchase the measurement probe options appropriate for your application separately.
Ideal for measuring these component characteristics:
The resistance of high-resistance components
The resistance of liquids such as adhesives and alcohol
The resistance of film materials
The resistance of materials used in automobile seats
The leakage current of semiconductor protective diodes
Components with high insulation resistance such as capacitors
SUPER MEGOHM METER SM7110, SM7120
NEW
Model No. (Order Code)
Setting voltage
range
SM7110 (1ch, Max. 1000V output)
SM7120 (1ch, Max. 2000V output)
Current Limiter
Measurement
time setting
Flexible, Multipurpose Design,
Max. 2×1019 Ω Display
Functions
l 300x Noise Resistance (Compared to legacy model)
l Rapid 6.4 ms High-Speed Inspection
l Low capacity contact checks for Picoammeter Mode
l Max. 2×1019 Ω Display, Min. 0.1 fA Resolution
l Built-in EXT I/O, LAN, RS-232C, GP-IB and USB
l Flexible, Multipurpose Design (Electrometer, Picoammeter, IR Meter)
SUPER MEGOHM METER SM-8220
Model No. (Order Code) SM-8220
Super Megohm
Measurement in Any Field
l Ultra megohm measurement
l Digital/analog display on LCD
l Compatible for measurement of several sample
types with electrodes & other devices
Not CE Marked
Special Materials
Materials for Electronic Components
High Insulation
Measurement
Quality
Monitoring
Anti-Static
Protection
Film Capacitors
Ceramic Capacitors
Insulating Oil
Machine Oil
Wires
Cables
Harnesses
Paints
Flooring Materials
Carpeting
IC Trays
Water
Monitoring
Safety Law
Compliance
0.1 to 100.0 V, 100 mV resolution, Accuracy: ±0.1 % of setting ±0.05% f.s.
100.1 to 1000 V, 1 V resolution, Accuracy: ±0.1 % of setting ±0.05% f.s.
[SM7120 only] 1000 to 2000 V,1 V resolution, Accuracy: ±0.2 % of setting ±0.10% f.s.
0.1 to 250.0 V: 5/ 10/ 50 mA, 251 to 1000 V: 5/ 10 mA, to 2000 V:1.8 mA
Delay: 0 to 9,999 ms
Comparator measurement, deviation measurement, percentage measurement,
surface resistivity, volume resistivity, voltage monitor, contact check
10 types of discharge, charge, measure and measurement sequence discharge
patterns can be programmed.
Program function
GP-IB, RS-232C, USB or EXT I/O Interface
Interfaces
100 to 240V AC , 50/60 Hz, 45 VA
Power supply
Dimensions and mass 330 mm (12.99 in)W × 80 mm (3.15 in)H × 450 mm (17.72 in)D, 6.7 kg (208.1 oz)
Measurement leads are not included. Purchase the appropriate lead option for your application separately.
Basic specifications
Measuring
resistance
range
Measuring accuracy
Output current
Standard function
Interfaces
Power supply
Dimensions and mass
10 V
25 V
50 V
100 V
5 ×104 - 2 ×1014 Ω
1.25 ×105 - 5 ×1014 Ω
2.5 ×105 - 1 ×1015 Ω
5 ×105 - 2 ×1015 Ω
250 V
500 V
1000 V
1.25 ×106 - 5 ×1015 Ω
2.5 ×106 - 1 ×1016 Ω
5 ×106 - 2 ×1016 Ω
±10 % (within 10 times range of min. value on each range at 20°C), but ± 20 % at 108 range
Max. 2 mA
Timer (1 to 999s), Comparator, Remote start, HV-EN (interlock)
RS-232C, Comparator output (open-collector)
Selectable 100, 120, 220 or 240 V AC ±10%, 50/60 Hz, 25 VA
284 mm (11.18 in)W × 139 mm (5.47 in)H × 215 mm (8.46 in)D, 4.3 kg (151.7 oz)
Application Map
Printed Circuit Boards
Ceramic Circuit Boards
Isopropyl Alcohol
Quality
Testing
Basic specifications
20 pA range (0.1 fA resolution) to 2 mA range (1 nA resolution), 9 ranges
DC current
measurement
(2 mA range: Measurement speed FAST only)
Resistance
50 Ω to 2 × 1019 Ω
measurement
capabilities
Cloth, Paper
Pills (Powdered)
Dynamite
Food, Medicine Capsules
Electrical Products
Electronic Components
Other
ELECTRODE FOR CHIP CAPACITOR
SME-8360
LIQUID SAMPLE ELECTRODE
SME-8330
SHIELDING BOX
SME-8350
WEIGHT ELECTRODE
SME-8320
SURFACE/VOLUME RESISTANCE
SM9001
MEASUREMENT ELECTRODE
SURFACE RESISTANCE MEASURESME-8301
MENT ELECTRODE
ELECTRODE FOR SURFACE
RESISTANCE
SME-8302
PLATE SAMPLE ELECTRODE
SME-8310
ELECTRODE FOR FLAT
SAMPLE
SME-8311
Electrode not required
When connecting electrodes and shield boxes to SM7110/SM7120, note that CONVERSION ADAPTER Z5010 or a change of connectors is required.
16
Electrodes
Options for Super Megohm Meters
For surface resistance or volume resistance measurement)
Not CE Marked
SURFACE/VOLUME RESISTANCE MEASUREMENT ELECTRODE SM9001
• Electrodes compliant with the JIS C 2170 and IEC
61340-2-3 standards
• Measurement voltage up to 1,000 V, and
measurement resistance up to 1013 Ω
• Surface and volume resistance of sheets and films
can be measured just as they are without the need
to cut samples
• Measure the surface resistance of antistatic
flooring and molded products
*When used with the SM-8200 series, measurement can take
full advantage of the instrument’s voltage and resistance ranges.
Dimensions: φ 100mm (3.94in) × 223mm (8.78in), Mass: 2.5 kg (88.2oz), Cable length: 1 m (3.28 ft)
(With integrated low resistance [500 kΩ]/high resistance [1 TΩ] test surfaces)
Electrode for surface resistance SME-8301
Not CE Marked
Surface resistance can be easily measured
by simply pushing the electrode against the
specimen. It measures surface resistance of antistatic related goods in combination of mainly
Model SM-8213. Measure resistance up to 1011 Ω.
Dimensions: φ 60mm (2.36in) × 50mm (1.97in)
Lead length: 1m (3.28ft)
Ring electrode
Main Measurement
electrode
object
Surface Resistance Measurement
Measu re the su rface resistance
between the main electrode and ring
electrode of the main body electrode.
Sample of 100mm square by up to 8mm in
thickness is measurable. The main electrode dia.
is 50mm and inner & outer dia. of ring electrode
are 70mm & 80mm respectively. Measurement
voltage becomes “OFF” while the lid is open to
ensure safety. A selector switch allows selection
of voltage or surface resistivity.
This is an electrode for plate sample for use
together with SME-8350 shield box. This electrode
enables extremely easy measurement of surface
resistivity and volume of sample with coarse
surface such as carpets, etc. The main electrode
dia. is 50mm, and the ring electrode inner-dia. and
outer-dia. are 70mm and 80mm respectively.
Not
CE Marked
This is used as a sample accommodation box
during measurement of a high-insulation resistance samples, or inductive or capacitive samples
to perform electromagnetic shielding.
Dimensions: 250mm (9.84in) W × 100mm (3.94in)H × 200mm (7.87in)D
Lead length: 80cm (2.62ft)
Included: Rubber sheet
Not CE Marked
Standard resistor box SR-2
This is a resistor box for calibration of the super
megohmmeters. Max. voltage is 1,000 V DC and
resistor value covers from 10 MΩ to 10,000 MΩ
in 24 points.
Ring electrode
Main
electrode
Electrode for surface resistance SME-8302
Not CE Marked
An electrode distance:
4mm (0.16in)
Electrode for surface resistance of curved samples
such as resin and rubber processed goods, TV
cathode tubes or small samples. Surface resistance
can be measured by pressing the rubber tips at the
tip onto the sample. Measure electrodes up to 1011
Ω at 10mm intervals or greater.
Dimensions: φ 40mm (1.57in) × 115mm (4.53in)
Lead length 1m (3.28ft)
Electrode for plates SME-8311
Not CE Marked
Sample of 40~100mm square by up to 8mm in
thickness is measurable. The main electrode dia.
is 19.6mm and inner & outer dia. of ring electrode
are 24.1mm & 28.8mm respectively. Measurement
voltage becomes “OFF” while the lid is open to
ensure safety. The fundamental specifications are
the same as SME-8310.
*A separately purchased interlock cable (DSM8104F) is
required in order to use the product with the DSM-8104.
Dimensions: 215mm (8.46in) W × 78mm (3.07in)H × 165mm (6.50in)D
Lead length 75cm (2.46ft)
Electrode for liquid samples SME-8330
Not CE Marked
Included: Banana clips ×2
Photo is Combination with Shield box SME-8350
Shield box SME-8350
Measure the volume resistance of the
sample sandwiched between the main
electrode and counter-electrode.
Not CE Marked
Dimensions: 215mm (8.46in) W × 78mm (3.07in)H × 165mm (6.50in)D
Lead length: 75cm (2.46ft)
Not CE Marked
Volume Resistance Measurement
. he SM9002 Verification Fixture for Surface Resistance Measurement (option) allows you
T
to check the operation of the electrode to increase the reliability of measurement results.
*A separately purchased interlock cable (DSM8104F) is
required in order to use the product with the DSM-8104.
Weight electrode SME-8320
Main
electrode
VERIFICATION FIXTURE FOR SURFACE RESISTANCE MEASUREMENT SM9002
Electrode for plate samples SME-8310
Not CE Marked
Measurement
object
Counter
electrode
Included: Connection cable
60cm (1.97ft) length
(Red) 0GA00029 ×1
(Black) 0GA00030 ×1
Electrode for liquid samples which is electrically
guarded. Total volume is 25ml. Capacitance
between main and counter electrode is approx.
45pF. Electrode constant is approx. 500cm.
Distance between both electrodes is 1mm. Outer
dia. is 36mm, height is approx. 140mm. Measure
resistance up to 1019 Ω (at 1000V) when used
together with Model SM-8220.
Dimensions: φ 36mm (1.42in) × 140mm (5.51in)
Included: Inspection data sheet
Electrode for chip capacitor SME-8360
Not CE Marked
For measuring the resistance of tip capacitors, with
adjustable jig from 0mm to 11mm. When connected
to the meter by an interlock cable, measurement
voltage becomes “OFF” while the lid is open to
ensure safety.
The interlock cable must be modified in order to use the product with the SM-8220 series.
Dimensions: 200mm (7.87in) W × 520mm (2.05in)H × 150mm (5.91in)D
*A separately purchased interlock cable (DSM8104F) is
required in order to use the product with the DSM-8104.
Dimensions: 270mm (10.63in) W × 90mm (3.54in)H × 195mm (7.68in)D
Included: Inspection data sheet
17
Digital Multimeters
Use for measurement applications like these…
Measuring nanovolt-order voltages in superconductivity applications
Collecting data from remote locations in applications such as earthquake research
Measuring inverter-equipped systems
Measuring the voltage of solar panels
Logging high-resolution sensor data
Verifying ripple voltage in DC power supply systems
Monitoring the voltage of battery cells
Measuring the voltage of vehicle batteries
Performing natural discharge tests of batteries
Measuring lead-acid battery cell voltage variability
Recording biological signal waveforms
Measuring thermoelectromotive force
Example application DM7275/DM7276
Example application DM7275/DM7276
Higher-resolution and lower-noise measurement than an oscilloscope
High-precision DC current measurement
In high-speed sampling mode, the DM7275/DM7276 can make up to 5000 successive
measurements in response to a single trigger event. Integration times can be set from 1
ms. This capability makes it easy to acquire data in applications where the target waveform is likely to be obscured by noise when observed with an oscilloscope, for example
in logging data from sensors requiring a high degree of resolution, recording biological
signals, and measuring nanovolt-order voltages in superconductivity.
Measure output from a high-precision shunt resistor (current sensing resistor). Current values can be displayed
using the scaling function.
R=
ΔV
ΔI
Current
Shunt
resistance
Voltage
DC-IR measurement waveform for a battery
1 ms / sample
5 sec
PRECISION DC VOLTMETER DM7275/DM7276
7-1/2 Digit, 9ppm High Precision DC Voltmeter
for Lithium-ion Batteries
l High-accuracy model with 1-year 9ppm Accuracy: DM7276
l Basic model with 1-year 20ppm Accuracy: DM7275
l Capacitance contact check (using built-in C-monitor)
l Built-in EXT I/O, LAN, and USB
Model No.
(Order Code)
Basic specifications
DC Voltage
Basic accuracy
Temperature
Integration time
Measurement support functions
Management support functions
Contact check
Interfaces
Power supply
Dimensions and mass
Test leads A
TEST LEAD
L9207-10
90 cm (2.95 ft) length
18
DM7276-01
DM7276-02
DM7276-03
(standard model)
(with GP-IB)
(with RS-232C)
DM7275-01
DM7275-02
DM7275-03
(standard model)
(with GP-IB)
(with RS-232C)
DM7276
DM7275
10 V range: ±0.0009 % rdg. ±3 μV
10 V range: ±0.0020 % rdg. ±3 μV
100 mV ( ±120.000 00 mV) to 1000 V ( ±1000.000 0 V ), 5 ranges
-10.0°C to 60.0°C (14.0°F to 140°F), combined with sensor Z2001: ±0.5°C (5.0°C to 35°C)
Integration time unit: PLC/ms (PLC setting: 0.02/ 0.2/ 1/ 10/ 100, ms setting: 1 ms to 9999 ms)
Smoothing function, null, temperature compensation, scaling, over-range display, auto-hold, contact check
Comparator, BIN, absolute value judgment, label display, statistics, measurement information, communication monitor, EXT. I/O TEST
Check signal: 10 mV rms, threshold value: 0.5 nF to 50 nF (Cannot use in the 100 V/1000 V ranges), Contact check integration time: 1 ms to 100 ms
Standard: LAN (100BASE-TX), EXT. I/O, USB flash drive / USB device (USB2.0 Full-Speed)
Optional: GP-IB (-02 type only) / RS-232C (-03 type only) / PRINTER (-03 type only)
100 to 240 V AC, 50/60 Hz, 30 VA
215 mm (8.46 in) W × 88 mm (3.46 in) H × 232 mm (9.13 in) D, (-01 type): 2.3 kg (81.1 oz), (-02/-03 type): 2.4 kg (84.7 oz)
Options for the L9207-10
CONTACT PIN
SET L4933
Attaches to the tip of
the Test Lead L9207-10/
DT4911, L9206,
70V DC/ 33V AC
SMALL ALLIGATOR
CLIP SET
L4934
Attaches to the tip of the
L4932, L9207-10/DT4911,
L9206,
CAT III 300V, CAT II 600V
Test leads B
Options for the L4930, Test Pin Set L4932 is required when using the Small Alligator Clip Set L4934.
CONNECTION
CABLE SET
L4930
EXTENSION
CABLE SET
L4931
TEST PIN SET
L4932
SMALL ALLIGATOR
CLIP SET L4934
ALLIGATOR
CLIP SET L4935
BUS BAR CLIP
SET L4936
GRABBER CLIP
9243
1.2 m (3.94 ft)
length
Expands the length of
the cable with banana
plug, 1.5 m (4.92 ft)
length
Attaches to the tip of
the banana plug cable,
CAT IV 600V,
CAT III 1000V
Attaches to the tip of the
L4932, L9207-10/DT4911,
L9206, CAT III 300V,
CAT II 600V
Attaches to the tip of
the banana plug cable,
CAT IV 600V,
CAT III 1000V
Attaches to the tip
of the banana plug
cable, CAT III 600V
Attaches to the tip of
the banana plug cable,
196 mm (7.72 in) length,
CAT III 1000 V
Digital Multimeters
DIGITAL MULTIMETER DT4200 sereis
Introducing an extensive line of instruments with advanced safety features and high-speed response
l High-end models:
Featuring high accuracy, extensive additional functionality, and a broad range of measurement parameters
l Standard models:
Introducing a line of field-optimized instruments that can be chosen based on the application at hand
l Pocket models:
Featuring a compact body for ergonomic hold and a reliable, safe design
Basic
specifications
Principal
applications
DC voltage
AC voltage
DC + AC voltage
DC current
AC current
AC current
(use with Clamp on probes)
Resistance
Temperature
(thermocouples)
C (capacitance)
High-end models
DT4281
DT4282
For electrical
work in the field
For laboratory and
research use
Dimensions
and mass
Standard models
DT4254
DT4255
60 mV to 1000 V
6 V to 1000 V
6 V to 1000 V
Pocket models
DT4256
60 mV to 1000 V
DT4221
DT4222
For electrical
work in the field
For laboratory and
research use
600 mV to 600 V
6 V to 600 V
---
---
---
---
---
---
---
600 μA to 600 mA
600 μA to 10 A
6 A/10 A
60 μA to 60 mA
---
---
60 mA to 10 A
---
---
600 μA to 600 mA
600 μA to 10 A
6 A/10 A
---
---
---
600 mA to 10 A
---
---
10 A to 1000 A
---
---
10 A to 1000 A
---
10 A to 1000 A 10 A to 1000 A
---
---
---
600 Ω to 60 MΩ
---
600 Ω to 60 MΩ
---
---
---
1μF to 10mF
--1μF to 10mF
99.99 Hz (5 Hz or more) to 99.99 kHz, 4 ranges
(limited by the minimum detectable voltage and current)
Yes
Yes
--Yes
Yes
---
60 Ω to 600 MΩ
600 Ω to 60 MΩ
K: -40.0 to 800.0 °C (-40.0 to 1472.0°F)
1nF to 100mF
AC V, DC+AC V, AC A measurement:
99.999 Hz (0.5 Hz or more) to 500.00 kHz, 5 ranges
Yes
Yes
Continuity check
Yes
Yes
Diode test
Power supply
DT4253
For laboratory For instrumenVoltage
For electrical
Multifunction
and
tation
measurement
work in the
model
research use
4-20mA
only model
field
600 mV to 1000 V
600 mV to 1500 V
600 mV to 1000 V
Frequency
Conductance
Voltage detection
DT4252
---
600nS
----LR6 (AA) alkaline batteries ×4, Continuous
use: 100 hours
93mm(W)×197mm(H)×53mm(D)
(3.66”W×7.76”H×2.09”D Inch)
650g (including batteries) (23 oz.)
K: -40 to 400 °C
(-40 to 752°F)
---
---
1μF to 10mF
AC V measurement:
99.99 Hz (5 Hz or more) to 9.999 kHz, 3 ranges
Yes
Yes
Yes
Yes
---
Yes
Yes
---
Yes
---
---
---
---
---
---
---
---
---
Yes
Yes
Yes
Alkaline (LR03) battery ×4
Continuous use: 130 hours
84mm(W)×174mm(H)×52mm(D)(3.31”W×6.85”H×2.05”D Inch)
390g (including batteries and holster) (13.8 oz.)
Measure output voltage on the secondary sides of inverters
Accurately measure the fundamental wave alone by eliminating harmonic components
with the DMM’s low-pass filter function.
With low-pass filter off
---
With low-pass filter on
Yes
--Alkaline (LR03) battery ×1
Continuous use: 40 hours
72mm(W)×149mm(H)×38mm(D)
(2.83”W×5.87”H×1.50”D Inch)
190g (including batteries and holster) (6.7 oz.)
Ripple voltage confirmation of DC charging systems
Peak value measurement / DC + AC voltage measurement
High-end models can detect ripple
voltage with a superposed DC signal.
Input
waveform
114.1 V
85.9 V
100 V
DC + AC measurement*
0V
*DC + AC value =
0V
Fundamental component
Fundamental component
Harmonic component
Harmonic component
+
+
Percentage display for instrumentation signal measurement
4 to 20 mA / 0 to 20 mA percentage-equivalent display
You can check
percentage-equivalent values.
Output 1
4 mA
Display
0%
20 mA
100%
Output 2
Display
20 mA
100%
4 mA
0%
Temperature
√
100.49 V
(AC)2 + (DC)2
+Peak measurement
114.10 V
-Peak measurement
85.90 V
Manage measurement data on a computer
Using the Communication Package DT4900-01 (option)
Measurement results can be downloaded to a computer via a USB connection. Once
downloaded, you can save them as a file (text format) or display them as a graph using the
desired interval. Results can also be sent in real time while measurement is ongoing.
*The computer and multimeter are
electrically isolated by means of
optical communications so that data
can be sent with peace of mind.
Pressure
Flow rate
Transducer
19
Current Probes / Current Sensors
Choose the current probe that’s
right for your application
Use for measurement applications like these…
Measuring inverter switching waveforms
Measuring current in EVs, HEVs, and other electric vehicles
l Input directly to your oscilloscope or Memory HiCorder’s
BNC terminal (except broadband power measurement)
l Make high-precision measurements across a broad operating
temperature range (-40°C to 85°C): CT6840s
l Observe minuscule currents of just 1 mA, 10 times previous models: CT6700, CT6701
l Easily observe current waveforms simply by clipping around a conductor (except CT686x, 9709)
l Delivers broadband, high-precision, high-current (1000 A) measurement across a broad range of
operating temperatures (-30°C to 85°C): CT6865
Measuring current in solar power installations
Measuring battery discharge current
Performing evaluation testing of fuel cells
Current Probes to Observe DC to MHz Bandwidth Waveforms on Oscilloscopes and Memory Recorders (options: POWER SUPPLY 3269, 3272)
Model No. (Order Code)
CT6700
CT6701
3273-50
3276
3274
3275
POWER SUPPLY 3269
POWER SUPPLY 3272
Frequency band- DC to 50 MHz DC to 120 MHz DC to 50 MHz DC to 100 MHz
width
(-3 dB)
(-3 dB)
(-3 dB)
(-3 dB)
Continuous Max.
input range
5 A rms
Output voltage rate
Measurement
conductor
DC to 2 MHz
(-3 dB)
150 A rms
500 A rms
30 A rms
1V/A
0.1V/A
0.01V/A
φ 5 mm (0.20 in) Core dia.
φ 5 mm (0.20 in) Core dia.
φ 20 mm (0.79 in) Core dia.
Typ.: ±1.0% rdg. ±1mV
Amplitude accuracy
DC to 10 MHz
(-3 dB)
(DC, 45Hz to 66Hz, 0 to 5A)
±1.0% rdg. ±1mV
(DC, 45Hz to 66Hz, 0 to 30A)
±1.0% rdg. ±1mV
Compatible sensors:
up to 2 units
Compatible sensors:
up to 4 units
3273-50, 3274, 3275
or 3276: up to 1 unit
SENSOR UNIT
9555-10
The optional POWER SUPPLY 3272 or 3269, or 9555-10 is
required in order to supply power and connect the clamp to
a Memory HiCorders. The clamp can be directly connected
the Power Analyzer PW6001 and 3390.
±1.0% rdg. ±5mV
(DC, 45Hz to 66Hz, 0 to 150A) (DC, 45Hz to 66Hz, 0 to 500A)
Current Probes to Observe Waveforms Using Wide-Band Power Analyzers PW6001(use -05 sensor models), 3390 for input current
(Can also be used to observe waveforms, Option: SENSOR UNIT 9555-10)
Model No. (Order Code)
-05: 12pin terminal
Rated input current
Amplitude
Frequency
characteristics Phase
Output voltage rate
Measurement conductor
CT6841
CT6841-05
CT6843
CT6843-05
CT6844
CT6844-05
NEW
CT6845
CT6845-05
CT6846
CT6846-05
NEW
NEW
CT6862
CT6862-05
CT6863
CT6863-05
20 A AC/DC
200 A AC/DC
500 A AC/DC
1000 A AC/DC
DC to 1 MHz
DC to 500 kHz DC to 200 kHz DC to 100 kHz
DC to 20 kHz
DC to 300 kHz DC to 300 kHz DC to 200 kHz DC to 100 kHz
DC to 20 kHz
0.1 V/A
0.01V/A
4 mV/A
2 mV/A
φ 20 mm (0.79 in) Core dia.
φ 50 mm (1.79 in) Core dia.
50 A AC/DC
200 A AC/DC
DC to 1 MHz
DC to 500 kHz
DC to 300 kHz DC to 300 kHz
2 V/ 50 A
2 V/ 200A
φ 24 mm (0.94 in) Core dia.
±0.3% rdg. ±0.01% f.s., ±0.1°
(DC < f ≤ 100 Hz)
±0.05% rdg. ±0.01% f.s., ±0.2°
(DC, 16Hz ≤ f ≤ 400 Hz)
Amplitude and
Phase accuracy
CT6865
CT6865-05
9709
9709 -05
1000 A AC/DC
500 A AC/DC
DC to 20 kHz
DC to 100 kHz
DC to 1 kHz
DC to 100 kHz
2V/ 1000A
2 V/ 500 A
φ 36 mm (1.42 in) Core dia.
±0.05% rdg. ±0.01% f.s., ±0.2°
(DC, 16Hz ≤ f ≤ 66 Hz) (DC, 45Hz ≤ f ≤ 66 Hz)
AC/DC Current Clamps (Long-term waveforms recording/measuring, option: DISPLAY UNIT CM7290, CM7291)
Model No. (Order Code)
CT7742
CT7736
CT7731
Accurate, Long-term Recording and Easy Output Settings
NEW
Rated input current
NEW
NEW
2000 A AC/DC
600 A AC/DC
100 A AC/DC
DC to 5 kHz (-3 dB)
Output voltage rate
0.1 mV/A
1 mV/A
Measurement conductor φ 55 mm (2.17 in) Core dia.
φ 33 mm (1.30 in) Core dia.
Frequency characteristics
Amplitude accuracy
(Typ.)
Phase accuracy
CT7642
CT7636
CT7631
Accurate, Instantaneous Waveforms Recording and Easy Output Settings
NEW
NEW
NEW
600 A AC/DC
100 A AC/DC
DC to 10 kHz (-3 dB)
0.1 mV/A
1 mV/A
φ 55 mm (2.17 in) Core dia.
φ 33 mm (1.30 in) Core dia.
DISPLAY UNIT
CM7290, CM7291
NEW
2000 A AC/DC
±1.5% rdg. ±0.5% f.s.
±2.0% rdg. ±0.5% f.s. ±1.0% rdg. ±0.5% f.s.
±1.5% rdg. ±0.5% f.s.
±2.0% rdg. ±0.5% f.s. ±1.0% rdg. ±0.5% f.s.
±2.3 deg. (DC < f ≤ 66 Hz)
±1.8 deg. (DC < f ≤ 66 Hz)
±2.3 deg. (DC < f ≤ 66 Hz)
±1.8 deg. (DC < f ≤ 66 Hz)
Power supply and signal
output for Current Sensor
CT7600, CT7700 series
Note: Company names and Product names appearing in this catalog are trademarks or registered trademarks of various companies.
HIOKI (Shanghai) SALES & TRADING CO., LTD.
TEL +86-21-63910090 FAX +86-21-63910360
http://www.hioki.cn / E-mail: [email protected]
DISTRIBUTED BY
HIOKI SINGAPORE PTE. LTD.
TEL +65-6634-7677 FAX +65-6634-7477
HEADQUARTERS
E-mail: [email protected]
81 Koizumi, Ueda, Nagano, 386-1192, Japan
TEL +81-268-28-0562 FAX +81-268-28-0568
HIOKI KOREA CO., LTD.
http://www.hioki.com / E-mail: [email protected] TEL +82-2-2183-8847 FAX +82-2-2183-3360
E-mail: [email protected]
HIOKI USA CORPORATION
TEL +1-609-409-9109 FAX +1-609-409-9108
http://www.hiokiusa.com / E-mail: [email protected]