ENGINEERING GUIDE VERTICAL STACKED WATER SOURCE HEAT PUMPS HIGH EFFICIENCY VSCS SERIES • 13 EER FORM 145.18-EG1 (317) FORM 145.18-EG1 (317) Nomenclature VERTICAL STACKED WATER SOURCE HEAT PUMP - CABINET VSB12 M 1 D A A 2 2T 4 0 A PRODUCT CATEGORY DESIGN SERIES A = Current VSB = Vertical Stacked Heat Pump - Standard Cabinet Assembly VSM = Vertical Stacked Heat Pump - Master Cabinet Assembly VSS = Vertical Stacked Heat Pump - Slave Cabinet Assembly VST = V ertical Stacked Heat Pump - Standard Cab Single Riser Assembly MISC. OPTIONS OPTION Galv Drain Pan SST Drain Pan Sealed Openings SST DP w/ Sealed 0 S L C F T M D G U N E HORIZONTAL DISCHARGE OPENING ORIENTATION UNIT CAPACITY 09 = .75 TON 24 = 2 TON 30 = 2.5 TON 12 = 1 TON 15 = 1.25 TON 36 = 3 TON 18 = 1.5 TON 00, 0T 1H, 1T X = None B = Back F = Front L = Left R = Right CONTROL OPTIONS Thermostat Location Remote Whip Surface ADA Door 2-Speed UnitMounted Switch M W P A 3-Speed Thermostat Control 3 4 5 7 2H, 2T 3H, 3T 1 = Left + Front 7 = Front + Left + Right 2 = Left + Back 8 = Front + Right + Back 3= Left + Right 9 = F ront + Left + Back 4 = Right + Back 5 = Right + Front 6 = Back + Front SUPPLY AIR CONFIGURATION 1H = Single Horizontal Supply 2H = Double Horizontal Supply 3H = Triple Horizontal Supply 0T = Top Only 1T = Single Horizontal Supply + Top 2T = Double Horizontal Supply + Top 3T = Triple Horizontal Supply + Top 00 = Field Cut (No Openings) VOLTAGE 1 = 208/230-60-1 6 = 265-60-1 ELECTRICAL CONNECTION O = None (Terminal Block) D = Non-Fused Disconnect F = Disconnect w/Fuses RISER ARRANGEMENT BLOWER OPTIONS A = PSC Blower B = Hi-Static PSC E = ECM Blower F = Hi-Static ECM FILTERS: MERV (DEPTH) 4 (1") 8 (1") 13 (2") 1 = Right Hand Risers 2 = Left Hand Risers 3 = Back Risers 4 = R/Hand Risers With Cover 5 = L/Hand Risers With Cover 6 = Back Risers With Cover G= ECM w/ Continuous Low Speed H = Hi-Static ECM w/ Continuous Low Speed CABINET OPTIONS 2 CABINET HEIGHT NO OA OPTIONS LEFT TOP OA ENTRY - 4" ROUND 88" Cabinet 80" Cabinet 80" Cabinet w/ 2" Stand 80" Cabinet w/ 2" Stand 80" Cabinet w/ 4" Stand 80" Cabinet w/ 8" Stand A B C E D F G H J 1 K 2 LEFT TOP OA ENTRY- 4" ROUND W/ MOTORIZED DAMPER L M N 3 P 4 RIGHT TOP OA ENTRY- 4" ROUND R T U 5 V 6 RIGHT TOP OA ENTRY - 4" ROUND W/ MOTORIZED DAMPER W X Y 7 Z 8 JOHNSON CONTROLS FORM 145.18-EG1 (317) VERTICAL STACKED WATER SOURCE HEAT PUMP - CHASSIS VSCS12C100AC0 PRODUCT CATEGORY MISC. OPTIONS UNIT CAPACITY WATERSIDE OPTIONS 0 = None S = Quiet Chassis C = Washer-less Hose Conn. B = Quiet Chassis w/ Washerless Hose Conn. VSCS = Vertical Stacked HP Chassis R-410 09 = .75 TON 24 = 2 TON 30 = 2.5 TON 12 = 1 TON 15 = 1.25 TON 36 = 3 TON 18 = 1.5 TON C = Standard Water Coil N = Cupro-Nickel Water Coil AIRSIDE OPTIONS A = Standard Airside Coil C = Corrosion Protective Coating DESIGN SERIES AUTO-FLOW REGULATOR C = Current VOLTAGE 1 = 208/230-60-1 6 = 265-60-1 WATER VALVE OPTIONS VALVE OPTIONS No Water Control Valve Motorized 2-Way Shut-Off Valve Motorized 3-Way Shut-Off Valve VALVE Y-STRAINER Y-STRAINER PUMP* ONLY & PUMP* O S M Y N V P B 0 = No Flow Control Valve B = 1.5 USGPM C = 2.0 USGPM D = 2.5 USGPM E = 3.0 USGPM F = 3.5 USGPM H = 4.0 USGPM J = 4.5 USGPM K = 5.0 USGPM L = 6.0 USGPM M = 7.0 USGPM N = 8.0 USGPM P = 9.0 USGPM R = 10.0 USGPM *Only available with Single Riser Cabinet (VST) Approvals JOHNSON CONTROLS 3 FORM 145.18-EG1 (317) Table Of Contents NOMENCLATURE.....................................................................................................................................................2 APPROVALS.............................................................................................................................................................3 TABLE OF CONTENTS.............................................................................................................................................4 INTRODUCTION........................................................................................................................................................5 PRODUCT OVERVIEW.............................................................................................................................................6 STANDARD AND OPTIONAL FEATURES...............................................................................................................7 PHYSICAL DATA..................................................................................................................................................... 11 AHRI/ISO 13256-1 PERFORMANCE DATA............................................................................................................12 PERFORMANCE DATA - PSC MOTOR..................................................................................................................13 PERFORMANCE DATA - EC MOTOR (ECM).........................................................................................................20 PERFORMANCE DATA...........................................................................................................................................27 RISER SELECTION AND DATA..............................................................................................................................28 BLOWER PERFORMANCE....................................................................................................................................29 ELECTRICAL DATA................................................................................................................................................31 DIMENSIONAL DATA..............................................................................................................................................33 HOSE KITS - NPSH WATER CONNECTION..........................................................................................................41 HOSE KITS - JIC WATER CONNECTION..............................................................................................................42 DISCHARGE CONFIGURATIONS..........................................................................................................................43 WIRING DIAGRAM..................................................................................................................................................46 SPECIFICATIONS....................................................................................................................................................49 4 JOHNSON CONTROLS FORM 145.18-EG1 (317) Introduction Performance, Value and Stainability in a Labor-Saving Package. The Vertical Stacked Water Source Heat Pumps (VSCS) from Johnson Controls offer the ultimate in multi-story HVAC design flexibility. The VSCS Series is a compact, concealed system, capable of providing total heating and cooling functions for a single zone or multiple rooms. These units offer the flexibility of a four-pipe fan coil system at the cost of a two-pipe system, with the added flexibility of individual tenant metering. VSCS Series units are ideally suited for the total heating and cooling needs of any two-plus story building with a consistent floor plan. • Hotels • High-Rise Apartments / Condominiums • Hospitals / Nursing homes • Dormitories • Renovated office space The space saving VSCS unit is a two-part system featuring a self-supporting, pre-piped cabinet, and a removable heat pump chassis. The cabinet, complete with supply/return/ drain risers, is installed during the intermediate phase of building construction. The cabinet is framed-in, and covered with drywall, as part of the interior wall structure. The finished equipment installation is hidden from view, blending with the decor of the room. Access to the mechanical components of the unit can be made entirely through the front/ return air panel. The provision for as many as three cabinet supply air outlets allows for maximum design flexibility and cost savings. One strategically located unit can serve up to three separate rooms without the need for ductwork. The ease of removal and replacement of the heat pump chassis offers enhanced serviceability. A chassis that requires service may be quickly removed, replaced with a back-up chassis, and serviced at a more convenient time or place. All units are tested and certified by AHRI / ISO 13256-1 and ETL for United States and Canada. Johnson Controls stacked heat pump design exceeds ASHRAE 90.1 requirements at all rating conditions, making the VSCS series an excellent choice for water-loop and geothermal applications. JOHNSON CONTROLS 5 FORM 145.18-EG1 (317) Product Overview Refrigerant R-410A Sizes 0.75 – 3 Tons (2.6 – 10.6 kW) Models Available Cabinets: VSB VSM VSS VST Standard Assembly Master Assembly Slave Assembly Standard Single Riser Assembly Chassis: VSCS Heat Pump Assembly Features 4 1. Terminal box 2. Double-deflection discharge grille (optional: opposed blade damper) 3 2 3. Sight/sound discharge baffles on all horizontal openings 4. Type M copper risers (optional: Type L) 5 1 5. Non-fused electrical disconnect 6. EC motor 6 7. Microprocessor control box 7 8. Stainless steel braided hoses 8 9. Copper tube aluminum fin refrigerantto-air coil 10. MERV 4 throw-away filter (optional: MERV 8) 9 11. ASHRAE 62.1 compliant removable double-sloped drain pan (optional: stainless steel) 12. Acoustic perimeter return air intake door (locking options available) 10 12 6 11 JOHNSON CONTROLS FORM 145.18-EG1 (317) Standard and Optional Features STANDARD FEATURES Construction • AHRI/ISO 13256-1 certified and labeled • Galvanized steel construction • ½” thick fiberglass insulation • Integral filter rack with 1” throwaway filter Decorator Front Panel • Perimeter intake return air door • Durable powder coat paint • Magnetic latches Supply Air • Front, back, side, and/or top outlets • Sight and sound baffles Air-to-Refrigerant Coils • R-410A direct expansion air coil • 3/8” O.D. seamless copper tubes • High efficiency aluminum fin surface for optimizing heat transfer, pressure drop, and carryover • Easily removable for service Water-to-Refrigerant Coils • Coaxial heat exchanger with convoluted inner tube design • Capable of operation with an entering fluid temperature range of 20°F to 110°F • Riser connection with stainless steel braided hoses Drain Pans • Single wall, galvanized steel • Fully insulated • P-trap factory installed • Condensate switch JOHNSON CONTROLS 7 FORM 145.18-EG1 (317) Standard and Optional Features (Cont'd) Fan Assemblies • Forward curved, DWDI centrifugal type blowers • 208/230V & 265V, single phase, PSC motors Electrical • cETL listed for safety compliance • Electrical enclosure with access door for field wiring terminations • Microprocessor controller handles reversing valve operation (no heat pump thermostat needed) • Terminal block for field connections • Single point power connection OPTIONAL FEATURES Construction • Master/Slave arrangements • 1” MERV 8 filter Decorator Front Panel • Quarter turn or key lock Supply Air • Double deflection discharge grille • Opposed blade damper Outside Air • 4” round connection on top left/right of cabinet • Motorized damper Drain Pans • Stainless steel construction Fan Assemblies • EC motors on all model sizes • High-static PSC and EC motors Electrical • Non-fused disconnect or disconnect with fusing Piping Options • 2-way and 3-way motorized valves • Fixed flow control valves • P/T ports and Y-strainers 8 JOHNSON CONTROLS FORM 145.18-EG1 (317) Thermostats • Digital display • Non-programmable or programmable • Fan speed control • ADA height thermostat mounting • Communicating thermostat options Risers • Type M or L copper with swaged connections • ¾” to 3” diameters • ½” and ¾” closed cell insulation • Type M copper condensate riser • Riser extensions • Riser cover • Ship in advance risers JOHNSON CONTROLS 9 FORM 145.18-EG1 (317) THIS PAGE INTENTIONALLY LEFT BLANK. 10 JOHNSON CONTROLS FORM 145.18-EG1 (317) Physical Data Table 1 - VSCS SERIES MODEL SERIES Nominal Cooling (Ton) 1 09 0.75 COMPRESSOR TYPE Refrigerant Charge (Oz) 12 15 18 24 1.0 1.25 1.5 2.0 ROTARY 23 31 AIR COIL-TYPE 30 36 2.5 3.0 50 52 SCROLL 35 40 46 ENHANCED COPPER TUBES, ENHANCED ALUMINUM FINS Face Area (Sq Ft) 1.46 1.56 2.35 2.35 2.63 3.33 3.33 Rows/Fpi 2/16 3/14 3/14 3/14 3/14 3/14 3/14 WATER COIL-TYPE ENHANCED SURFACE CO-AXIAL DWDI FORWARD-CURVED CENTRIFUGAL / PSC DIRECT-DRIVE Psc Blower/Motor Diameter X Width (In) 9x4T 9x4T 9x7T 9x7T 9x7 9x8 9x8 Motor Hp 0.10 0.10 0.17 0.17 0.25 0.33 0.50 HI-STATIC PSC BLOWER/MOTOR DWDI FORWARD-CURVED CENTRIFUGAL / PSC DIRECT-DRIVE Diameter X Width (In) 9x4T 9x4T 9x7T 9x7T 10x7T 10x8T 10x8T Motor Hp 0.10 0.10 0.17 0.25 0.33 0.33 0.50 ECM BLOWER/MOTOR DWDI FORWARD-CURVED CENTRIFUGAL / ECM DIRECT-DRIVE Diameter X Width (In) 9x4T 9x4T 9x7T 9x7T 10x7T 9x8 9x8 Motor Hp 0.33 0.33 0.33 0.33 0.33 0.50 0.50 HI-STATIC ECM BLOWER/MOTOR DWDI FORWARD-CURVED CENTRIFUGAL / ECM DIRECT-DRIVE Diameter X Width (In) 9x4T 9x4T 9x7T 9x7T 10x7T 10x8T 10x8T Motor Hp 0.33 0.33 0.33 0.33 0.33 0.50 0.50 Filter Quantity-Size (In) 1-14x25x1 1-14x25x1 1-16x30x1 1-16x30x1 1-16x30x1 1-20x30x1 1-20x30x1 Cabinet Weight (Lb) 2 130 130 145 145 150 175 175 Chassis Weight (Lb) 70 75 95 100 140 155 160 NOTE: 1. Nominal Capacity calculated in accordance with AHRI / ISO Standard 13256-1 for Water Loop Application 2. Cabinet weight is approximate and does not include weight of risers Table 2 - OPERATING LIMITS* COOLING HEATING MIN. ENTERING WATER 30 ºF 20 ºF MAX. ENTERING WATER 110 ºF 90 ºF *Units are capable of operation with an entering fluid temperature range of 20 ºF to 110 ºF JOHNSON CONTROLS 11 FORM 145.18-EG1 (317) AHRI/ISO 13256-1 Performance Data Table 3 - PSC MOTORS MODEL 09 12 15 18 24 30 36 WATER LOOP CONDITIONS1 GROUND WATER CONDITIONS2 GROUND LOOP CONDITIONS3 FLOW AIR COOLING HEATING COOLING HEATING COOLING HEATING RATE FLOW CAPACITY CAPACITY CAPACITY CAPACITY CAPACITY CAPACITY (USGPM) (SCFM) EER COP EER COP EER COP (BTUH)4 (BTUH)5 (BTUH)4 (BTUH)5 (BTUH)4 (BTUH)5 2.6 340 8,900 13.0 11,800 4.5 10,100 19.5 9,300 3.8 9,300 14.2 7,000 3.2 3.2 430 12,200 13.0 14,900 4.4 14,400 19.8 12,200 3.7 12,600 14.3 9,700 3.2 4.0 550 14,500 13.5 17,200 4.7 16,500 21.8 13,900 4.0 14,500 16.0 10,900 3.3 4.8 685 18,100 13.2 22,300 4.6 20,800 20.6 18,000 3.9 18,800 14.5 14,000 3.2 6.2 850 24,400 13.4 30,200 4.5 28,100 21.5 23,800 3.9 26,000 15.7 18,500 3.2 7.8 1075 30,000 13.5 34,900 4.6 33,500 20.0 27,500 3.7 31,800 15.2 20,500 3.2 9.5 1220 34,900 13.0 43,000 4.3 39,200 19.4 29,100 3.7 36,400 14.1 22,900 3.2 Table 4 - EC MOTORS (ECM) MODEL 09 12 15 18 24 30 36 WATER LOOP CONDITIONS1 GROUND WATER CONDITIONS2 GROUND LOOP CONDITIONS3 FLOW AIR COOLING HEATING COOLING HEATING COOLING HEATING RATE FLOW CAPACITY CAPACITY CAPACITY CAPACITY CAPACITY CAPACITY (USGPM) (SCFM) EER COP EER COP EER COP (BTUH)4 (BTUH)5 (BTUH)4 (BTUH)5 (BTUH)4 (BTUH)5 2.6 340 9,100 14.0 11,600 4.6 10,200 20.0 9,100 4.0 9,400 14.4 6,800 3.3 3.2 430 12,300 13.4 14,700 4.5 14,600 20.2 12,000 3.8 12,800 14.5 9,400 3.3 4.0 550 14,600 14.0 17,100 4.8 16,600 22.0 13,800 4.1 14,800 16.2 10,600 3.4 4.8 685 18,400 13.6 22,000 4.7 20,900 21.0 18,100 4.0 19,100 15.1 13,700 3.3 6.2 850 24,600 13.7 30,000 4.6 28,200 21.7 24,000 4.0 26,100 16.1 17,900 3.3 7.8 1075 30,100 13.8 34,400 4.7 33,900 20.6 27,100 3.9 32,200 15.6 20,100 3.3 9.5 1220 35,500 13.3 42,700 4.5 39,800 19.8 28,100 3.9 37,000 14.5 21,900 3.3 NOTES: 1. Water Loop capacities are rated at 86°F EWT Cooling, 68 °F EWT Heating. 2. Ground Water capacities are rated at 59°F EWT Cooling, 50 °F EWT Heating. 3. Ground Loop capacities are rated at 77°F EFT Cooling, 32 °F EFT Heating. 4. All Cooling capacities based upon 80.6°F DB, 66.2 °F WB entering air temperature. 5. All Heating capacities based upon 68°F DB, 59 °F WB entering air temperature. 12 JOHNSON CONTROLS FORM 145.18-EG1 (317) Performance Data - PSC Motor Table 5 - VSCS09 - PSC MOTOR - 340 CFM TC SC COOLING SHR KW HR EER 2.6 WPD PSI FT 6.8 15.7 HTG 5.3 KW 0.59 1.3 1.8 4.2 11.1 7.3 0.66 0.46 12.3 24.4 6.4 0.61 4.7 85.4 3.1 2.0 4.1 9.4 11.4 7.6 0.67 0.43 12.4 26.7 6.8 0.62 5.1 86.5 3.2 2.6 6.7 15.3 11.7 8.1 0.69 0.41 12.7 28.3 7.0 0.65 5.2 87.1 3.2 1.3 1.7 3.8 10.4 7.1 0.68 0.51 11.7 20.4 7.4 0.63 5.7 88.1 3.4 2.0 3.7 8.5 10.5 7.3 0.69 0.48 11.8 21.7 7.7 0.66 5.9 88.9 3.4 2.6 6.0 13.9 10.9 7.7 0.71 0.46 12.0 23.5 8.1 0.67 6.2 90.0 3.5 1.3 1.5 3.4 10.0 7.0 0.70 0.57 11.5 17.7 8.5 0.67 6.7 91.1 3.7 2.0 3.3 7.6 10.1 7.2 0.71 0.54 11.5 18.7 9.0 0.69 7.1 92.4 3.8 2.6 5.4 12.4 10.4 7.6 0.73 0.52 11.7 20.2 9.3 0.70 7.3 93.3 3.9 1.3 1.4 3.3 9.6 7.0 0.73 0.65 11.4 14.8 9.7 0.69 7.7 94.3 4.1 2.0 3.1 7.3 9.8 7.2 0.74 0.63 11.5 15.5 10.2 0.71 8.2 95.7 4.2 2.6 5.1 11.8 10.1 7.6 0.75 0.56 11.6 18.2 10.7 0.72 8.6 97.1 4.3 1.3 1.3 3.1 9.2 6.7 0.73 0.73 11.3 12.6 10.7 0.69 8.8 97.1 4.5 2.0 3.0 6.9 9.3 6.9 0.74 0.72 11.3 13.0 11.2 0.71 9.2 98.5 4.6 2.6 4.9 11.2 9.6 7.3 0.76 0.61 11.2 15.9 11.9 0.73 9.8 100.4 4.8 1.3 1.3 2.9 8.8 6.7 0.76 0.80 11.2 11.0 12.4 0.72 10.4 101.8 5.1 2.0 2.8 6.5 8.9 6.9 0.77 0.77 11.1 11.6 12.7 0.72 10.7 102.6 5.2 2.6 4.6 10.6 9.2 7.1 0.77 0.67 11.0 13.8 13.1 0.73 11.0 103.7 5.3 1.3 1.2 2.8 8.5 6.4 0.76 0.88 11.0 9.7 13.8 0.74 11.7 105.6 5.5 2.0 2.7 6.2 8.5 6.5 0.77 0.83 10.9 10.2 14.5 0.75 12.4 107.5 5.7 2.6 4.4 10.1 8.7 6.7 0.78 0.70 10.6 12.4 14.8 0.76 12.6 108.3 5.7 1.3 1.1 2.5 8.1 6.2 0.77 0.97 11.0 8.4 2.0 2.6 6.0 8.2 6.4 0.78 0.92 11.0 8.9 2.6 4.3 9.9 8.4 6.6 0.79 0.86 10.9 9.7 1.3 1.1 2.5 7.8 6.1 0.79 1.06 10.9 7.3 2.0 2.5 5.8 8.0 6.3 0.79 1.02 11.0 7.9 2.6 4.2 9.7 8.1 6.5 0.80 0.99 11.1 8.2 EWT GPM 20 30 40 50 60 70 80 90 100 110 HEATING HE LAT 3.7 82.4 COP 2.6 • Cooling Performance is tabulated at 80.6 °F DB and 66.2 °F WB entering air. Heating performance tabulated at 68 °F EAT • Tabulated data does not include AHRI/ISO corrections for fan and pump power. • All capacities are expressed in MBH. • Insulated water circuit is recommended for operation below 60 °F EWT. • See performance correction tables for conditions beyond what is listed. • Extrapolation is not permissible. • Blank areas indicate conditions where operation is not recommended. JOHNSON CONTROLS 13 FORM 145.18-EG1 (317) Performance Data - PSC Motor (Cont'd) Table 6 - VSCS12 - PSC MOTOR - 430 CFM WPD COOLING HEATING EWT GPM PSI FT 20 3.2 6.5 15.0 1.6 1.7 4.0 15.3 10.4 0.68 0.66 17.0 2.4 3.7 8.5 15.6 10.7 0.69 0.62 3.2 6.3 14.5 16.0 11.2 0.70 0.60 1.6 1.6 3.7 14.9 10.6 0.71 2.4 3.4 7.9 15.3 10.9 3.2 5.9 13.5 15.5 11.2 1.6 1.5 3.5 13.9 2.4 3.2 7.3 3.2 5.4 12.5 1.6 1.4 2.4 3.2 30 40 50 60 70 80 90 100 110 TC SC SHR KW HR EER HTG KW HE LAT COP 7.9 0.82 5.6 85.0 2.8 23.2 9.1 0.90 6.6 87.5 3.0 17.1 25.3 9.3 0.91 6.7 88.0 3.0 17.5 26.9 9.5 0.92 7.0 88.6 3.1 0.72 16.8 20.6 10.2 0.90 7.7 89.9 3.3 0.71 0.68 17.1 22.5 10.6 0.91 8.0 90.9 3.4 0.72 0.64 17.2 24.2 10.9 0.92 8.3 91.4 3.5 9.9 0.71 0.78 16.0 17.7 11.5 0.96 8.8 92.8 3.5 14.3 10.3 0.72 0.72 16.2 19.9 11.9 0.98 9.1 93.6 3.6 14.8 10.8 0.73 0.70 16.6 21.2 12.2 0.99 9.4 94.3 3.6 3.3 13.2 9.5 0.72 0.86 15.6 15.4 12.7 0.95 10.0 95.4 3.9 3.0 6.9 13.5 9.9 0.73 0.80 15.7 16.8 13.2 0.96 10.4 96.4 4.0 5.1 11.8 14.3 10.6 0.74 0.73 16.3 19.6 13.6 0.96 10.9 97.3 4.2 1.6 1.3 3.0 12.4 9.1 0.73 0.99 15.3 12.6 13.9 0.97 11.1 97.9 4.2 2.4 2.8 6.5 12.8 9.4 0.74 0.92 15.4 13.9 14.5 0.98 11.7 99.2 4.3 3.2 4.9 11.3 12.9 9.7 0.75 0.86 15.4 15.1 15.0 0.98 12.2 100.3 4.5 1.6 1.3 3.0 11.5 8.6 0.75 1.04 14.5 11.1 15.4 0.99 12.6 101.2 4.6 2.4 2.7 6.2 11.7 9.0 0.77 0.96 14.5 12.3 16.0 1.01 13.1 102.5 4.6 3.2 4.7 10.8 12.4 9.8 0.79 0.87 14.9 14.3 16.5 1.01 13.5 103.4 4.8 1.6 1.2 2.9 11.0 8.3 0.76 1.16 14.4 9.5 16.9 1.03 13.9 104.4 4.8 2.4 2.6 6.1 11.3 8.7 0.77 1.07 14.4 10.6 17.6 1.04 14.6 105.9 5.0 3.2 4.5 10.4 11.8 9.3 0.79 0.98 14.6 12.1 18.1 1.04 15.1 107.0 5.1 1.6 1.2 2.7 10.0 7.7 0.77 1.24 13.7 8.1 2.4 2.5 5.8 10.5 8.2 0.78 1.18 13.9 8.9 3.2 4.4 10.2 10.6 8.4 0.79 1.12 13.9 9.4 1.6 1.1 2.5 9.5 7.4 0.78 1.35 13.6 7.0 2.4 2.4 5.5 9.9 7.7 0.78 1.30 13.8 7.6 3.2 4.3 9.9 10.1 7.9 0.79 1.25 13.8 8.0 • Cooling Performance is tabulated at 80.6 °F DB and 66.2 °F WB entering air. Heating performance tabulated at 68 °F EAT • Tabulated data does not include AHRI/ISO corrections for fan and pump power. • All capacities are expressed in MBH. • Insulated water circuit is recommended for operation below 60 °F EWT. • See performance correction tables for conditions beyond what is listed. • Extrapolation is not permissible. • Blank areas indicate conditions where operation is not recommended. 14 JOHNSON CONTROLS FORM 145.18-EG1 (317) Table 7 - VSCS15 - PSC MOTOR - 550 CFM WPD COOLING HEATING EWT GPM PSI FT 20 4.0 7.0 16.2 2.0 1.9 4.5 18.6 13.8 0.74 0.69 20.3 3.0 4.1 9.5 18.8 14.1 0.75 0.63 4.0 7.0 16.2 18.8 14.3 0.76 0.59 2.0 1.9 4.3 18.1 14.0 0.77 3.0 4.0 9.1 18.5 14.3 4.0 6.7 15.6 18.3 14.3 2.0 1.8 4.1 16.9 3.0 3.8 8.7 4.0 6.5 14.9 2.0 1.6 3.0 4.0 30 40 50 60 70 80 90 100 110 TC SC SHR KW HR EER HTG KW HE LAT COP 8.8 0.93 6.4 84.3 2.8 26.9 9.7 0.98 7.0 85.7 2.9 20.2 29.7 10.5 0.79 8.5 86.2 3.9 20.1 31.8 10.8 1.01 8.1 88.1 3.1 0.76 20.0 23.9 11.9 1.01 9.2 88.7 3.4 0.77 0.70 20.1 26.5 12.3 1.03 9.5 89.3 3.5 0.78 0.64 19.7 28.6 12.7 1.04 9.8 90.4 3.6 12.7 0.75 0.83 19.0 20.5 13.3 1.05 10.5 91.4 3.7 17.2 12.9 0.75 0.74 19.0 23.2 13.9 1.05 11.1 92.0 3.9 17.3 13.2 0.76 0.69 19.0 25.0 14.3 1.06 11.4 93.3 4.0 3.6 15.9 12.1 0.76 0.89 18.2 18.0 15.0 1.06 12.2 94.2 4.2 3.3 7.7 16.1 12.3 0.76 0.83 18.2 19.5 15.6 1.06 12.7 94.9 4.3 5.7 13.1 16.3 12.4 0.76 0.80 18.3 20.4 16.0 1.07 13.0 95.5 4.4 2.0 1.4 3.3 15.0 11.7 0.78 0.98 17.6 15.2 16.3 1.06 13.4 96.6 4.5 3.0 3.1 7.0 15.2 12.1 0.79 0.94 17.7 16.2 17.0 1.08 14.1 97.6 4.6 4.0 5.2 12.0 15.4 12.2 0.79 0.91 17.7 16.8 17.6 1.09 14.6 98.5 4.5 2.0 1.4 3.2 14.3 11.5 0.80 1.08 17.2 13.2 18.1 1.11 15.1 99.3 4.8 3.0 2.9 6.7 14.5 11.6 0.80 1.04 17.3 13.9 18.6 1.12 15.5 100.0 4.8 4.0 5.0 11.4 14.5 11.7 0.80 1.02 17.3 14.3 19.0 1.15 15.8 100.3 4.8 2.0 1.3 3.0 13.6 11.1 0.82 1.18 16.9 11.4 19.2 1.16 16.0 101.0 4.9 3.0 2.8 6.4 13.8 11.3 0.82 1.13 16.9 12.2 19.6 1.17 16.3 101.3 4.9 4.0 4.7 10.9 13.9 11.5 0.83 1.13 17.0 12.4 19.8 1.18 16.5 68.0 4.9 2.0 1.2 2.8 12.8 10.6 0.83 1.30 16.5 9.8 3.0 2.6 6.0 13.0 10.9 0.84 1.26 16.6 10.3 4.0 4.4 10.2 13.2 11.1 0.84 1.24 16.7 10.6 2.0 1.1 2.6 12.0 10.3 0.86 1.45 16.3 8.3 3.0 2.5 5.8 12.3 10.7 0.87 1.40 16.4 8.8 4.0 4.5 10.3 12.5 10.8 0.87 1.38 16.5 9.1 • Cooling Performance is tabulated at 80.6 °F DB and 66.2 °F WB entering air. Heating performance tabulated at 68 °F EAT • Tabulated data does not include AHRI/ISO corrections for fan and pump power. • All capacities are expressed in MBH. • Insulated water circuit is recommended for operation below 60 °F EWT. • See performance correction tables for conditions beyond what is listed. • Extrapolation is not permissible. • Blank areas indicate conditions where operation is not recommended. JOHNSON CONTROLS 15 FORM 145.18-EG1 (317) Performance Data - PSC Motor (Cont'd) Table 8 - VSCS18 - PSC MOTOR - 685 CFM WPD COOLING HEATING EWT GPM PSI FT 20 4.8 7.5 17.3 2.4 2.0 4.7 22.2 15.1 0.68 0.75 24.0 3.6 4.3 9.9 22.3 15.2 0.68 0.72 4.8 7.3 16.8 22.6 15.6 0.69 0.69 2.4 1.9 4.5 21.3 14.9 0.70 3.6 4.1 9.5 21.5 15.3 4.8 7.0 16.1 21.9 15.8 2.4 1.9 4.3 20.5 3.6 3.9 9.1 4.8 6.7 15.5 2.4 1.6 3.6 4.8 30 40 50 60 70 80 90 100 110 TC SC SHR KW HR EER HTG KW HE LAT COP 11.4 1.29 7.7 83.4 2.6 29.7 13.0 1.30 9.3 85.6 2.9 24.0 31.1 13.5 1.30 9.8 86.2 3.1 24.2 33.0 13.9 1.32 10.2 86.8 3.1 0.88 23.6 24.2 14.6 1.30 10.9 87.7 3.3 0.71 0.83 23.6 25.9 14.9 1.31 11.2 88.2 3.4 0.72 0.80 23.9 27.5 15.5 1.33 11.7 88.9 3.4 14.8 0.72 0.98 23.1 20.9 16.6 1.31 12.9 90.5 3.7 21.5 15.7 0.73 0.91 23.9 23.5 17.3 1.32 13.5 91.4 3.8 21.3 15.5 0.73 0.88 23.5 24.3 18.0 1.33 14.2 92.3 4.0 3.8 19.7 14.4 0.73 1.14 22.8 17.3 19.0 1.32 15.2 93.6 4.2 3.5 8.0 20.5 14.9 0.73 1.07 23.3 19.2 19.8 1.34 15.9 94.7 4.3 5.9 13.6 20.8 15.4 0.74 1.02 23.5 20.4 20.3 1.37 16.4 95.5 4.4 2.4 1.5 3.5 18.9 14.1 0.75 1.29 22.5 14.6 21.2 1.34 17.3 96.6 4.6 3.6 3.2 7.3 19.1 14.5 0.76 1.22 22.5 15.7 22.1 1.36 18.2 97.9 4.8 4.8 5.4 12.5 19.4 14.9 0.77 1.18 22.7 16.4 22.8 1.39 18.8 98.8 4.8 2.4 1.4 3.3 17.8 13.4 0.75 1.45 22.0 12.3 23.2 1.35 19.3 99.4 5.0 3.6 3.0 7.0 18.2 14.0 0.77 1.36 22.1 13.3 24.2 1.38 20.3 100.7 5.2 4.8 5.2 11.9 18.6 14.7 0.79 1.27 22.1 14.7 25.2 1.40 21.2 102.1 5.3 2.4 1.4 3.1 17.0 13.1 0.77 1.64 21.9 10.4 24.9 1.37 21.0 101.7 5.3 3.6 2.9 6.6 17.4 13.6 0.78 1.55 22.0 11.3 25.8 1.39 21.8 102.9 5.4 4.8 4.9 11.3 17.8 14.1 0.79 1.46 22.0 12.2 27.7 1.41 23.6 105.4 5.7 2.4 1.3 3.0 15.8 12.3 0.78 1.82 21.2 8.6 3.6 2.8 6.5 16.3 12.7 0.78 1.72 21.4 9.4 4.8 4.8 11.1 17.0 13.4 0.79 1.67 22.0 10.2 2.4 1.2 2.8 14.9 11.6 0.78 2.08 21.2 7.2 3.6 2.7 6.2 15.4 12.2 0.79 1.96 21.3 7.9 4.8 4.7 10.8 16.2 13.0 0.80 1.90 22.0 8.5 • Cooling Performance is tabulated at 80.6 °F DB and 66.2 °F WB entering air. Heating performance tabulated at 68 °F EAT • Tabulated data does not include AHRI/ISO corrections for fan and pump power. • All capacities are expressed in MBH. • Insulated water circuit is recommended for operation below 60 °F EWT. • See performance correction tables for conditions beyond what is listed. • Extrapolation is not permissible. • Blank areas indicate conditions where operation is not recommended. 16 JOHNSON CONTROLS FORM 145.18-EG1 (317) Table 9 - VSCS24 - PSC MOTOR - 850 CFM WPD COOLING HEATING EWT GPM PSI FT 20 6.2 6.6 15.2 3.1 1.7 4.0 29.2 19.3 0.66 1.12 32.1 4.6 3.6 8.3 29.4 20.0 0.68 1.08 6.2 6.3 14.4 29.6 20.4 0.69 1.05 3.1 1.6 3.6 29.0 19.7 0.68 4.6 3.3 7.5 29.1 20.1 6.2 5.6 13.0 29.2 20.5 3.1 1.4 3.2 28.1 4.6 2.9 6.7 6.2 5.0 11.6 3.1 1.3 4.6 6.2 30 40 50 60 70 80 90 100 110 TC SC SHR KW HR EER HTG KW HE LAT COP 13.9 1.64 9.3 83.1 2.5 26.1 15.7 1.65 11.0 85.1 2.8 32.2 27.2 17.2 1.66 12.5 86.7 3.0 32.3 28.3 17.5 1.67 12.8 87.1 3.1 1.23 32.3 23.5 18.8 1.68 14.0 88.5 3.3 0.69 1.18 32.2 24.8 20.2 1.71 15.3 90.0 3.5 0.70 1.12 32.1 26.2 20.7 1.73 15.7 90.5 3.5 19.4 0.69 1.33 31.7 21.1 21.9 1.73 17.0 91.9 3.7 28.3 19.8 0.70 1.26 31.7 22.5 23.0 1.80 17.8 93.1 3.8 28.5 20.2 0.71 1.20 31.6 23.8 23.8 1.82 18.5 93.9 3.8 3.0 27.0 19.2 0.71 1.52 31.2 17.8 24.7 1.80 19.5 94.9 4.0 2.7 6.2 27.3 19.6 0.72 1.40 31.1 19.5 26.1 1.81 20.9 96.4 4.2 4.7 10.8 27.6 20.1 0.73 1.29 31.0 21.3 27.4 1.85 22.0 97.8 4.3 3.1 1.3 2.9 26.0 18.7 0.72 1.71 30.8 15.2 27.5 1.83 22.2 98.0 4.4 4.6 2.6 6.0 26.4 19.0 0.72 1.60 30.9 16.5 29.2 1.84 23.9 99.8 4.6 6.2 4.5 10.4 26.8 19.9 0.74 1.50 31.0 17.9 30.8 1.88 25.3 101.5 4.8 3.1 1.2 2.8 24.3 17.7 0.73 1.91 29.8 12.7 30.2 1.87 24.8 100.9 4.7 4.6 2.5 5.8 25.0 18.2 0.73 1.80 30.2 13.8 32.3 1.90 26.8 103.2 5.0 6.2 4.3 10.0 25.6 18.9 0.74 1.74 30.5 14.7 33.6 1.95 27.9 104.6 5.0 3.1 1.1 2.5 22.7 16.6 0.73 2.14 29.1 10.6 33.8 1.95 28.1 104.8 5.1 4.6 2.4 5.5 23.2 17.1 0.74 2.02 29.1 11.5 35.6 2.04 29.6 106.8 5.1 6.2 4.2 9.7 23.7 18.0 0.76 1.89 29.1 12.5 36.8 2.08 30.7 108.1 5.2 3.1 1.1 2.5 21.2 16.1 0.76 2.42 28.5 8.8 4.6 2.3 5.3 21.7 16.5 0.76 2.28 28.5 9.5 6.2 4.2 9.7 22.1 17.0 0.77 2.17 28.5 10.2 3.1 1.0 2.3 19.8 15.2 0.77 2.70 28.1 7.3 4.6 2.3 5.3 20.3 15.6 0.77 2.57 28.1 7.9 6.2 4.1 9.5 20.6 16.1 0.78 2.44 28.0 8.4 • Cooling Performance is tabulated at 80.6 °F DB and 66.2 °F WB entering air. Heating performance tabulated at 68 °F EAT • Tabulated data does not include AHRI/ISO corrections for fan and pump power. • All capacities are expressed in MBH. • Insulated water circuit is recommended for operation below 60 °F EWT. • See performance correction tables for conditions beyond what is listed. • Extrapolation is not permissible. • Blank areas indicate conditions where operation is not recommended. JOHNSON CONTROLS 17 FORM 145.18-EG1 (317) Performance Data - PSC Motor (Cont'd) Table 10 - VSCS30 - PSC MOTOR - 1075 CFM WPD COOLING HEATING EWT GPM PSI FT 20 3.9 5.6 12.9 3.9 1.5 3.5 34.8 23.7 0.68 1.37 38.3 5.8 3.1 7.2 35.3 24.4 0.69 1.35 7.8 5.4 12.5 35.6 24.9 0.70 1.33 3.9 1.4 3.2 35.3 24.3 0.69 5.8 2.9 6.6 35.7 25.4 7.8 5.0 11.4 35.8 25.8 3.9 1.2 2.9 34.0 5.8 2.6 6.0 7.8 4.5 10.4 3.9 1.2 5.8 7.8 30 40 50 60 70 80 90 100 110 TC SC SHR KW HR EER HTG KW HE LAT COP 17.4 1.89 12.0 82.9 2.7 25.4 20.4 1.92 15.0 85.6 3.1 38.8 26.2 21.1 1.95 15.6 86.2 3.2 39.0 26.8 21.9 1.96 16.4 86.9 3.3 1.45 39.1 24.3 21.9 1.98 16.3 86.9 3.2 0.71 1.41 39.4 25.3 22.9 2.04 17.0 87.7 3.3 0.72 1.37 39.4 26.1 23.8 2.09 17.8 88.5 3.3 24.5 0.72 1.52 38.1 22.4 25.3 2.08 19.3 89.8 3.6 34.4 25.1 0.73 1.48 38.3 23.3 26.5 2.16 20.3 90.9 3.6 34.5 25.5 0.74 1.46 38.3 23.7 28.6 2.21 22.2 92.6 3.8 2.8 32.9 24.0 0.73 1.72 37.7 19.2 29.5 2.14 23.3 93.4 4.0 2.5 5.8 33.4 24.7 0.74 1.68 38.0 19.9 31.1 2.20 24.7 94.8 4.1 4.3 10.0 33.4 24.7 0.74 1.64 37.9 20.3 32.3 2.24 25.8 95.8 4.2 3.9 1.2 2.7 31.2 22.8 0.73 1.91 36.6 16.4 32.8 2.19 26.4 96.2 4.4 5.8 2.4 5.6 31.7 23.5 0.74 1.83 36.8 17.3 34.5 2.24 28.0 97.7 4.5 7.8 4.2 9.6 32.3 24.3 0.75 1.90 37.7 17.0 35.8 2.25 29.3 98.8 4.7 3.9 1.1 2.6 29.7 21.9 0.74 2.14 35.8 13.8 34.9 2.20 28.5 98.1 4.6 5.8 2.3 5.4 30.2 22.7 0.75 2.06 36.1 14.7 36.1 2.25 29.5 99.1 4.7 7.8 4.0 9.3 31.0 23.6 0.76 2.15 37.2 14.5 36.9 2.26 30.4 99.8 4.8 3.9 1.0 2.4 28.1 21.1 0.75 2.38 35.1 11.8 36.4 2.22 29.9 99.4 4.8 5.8 2.2 5.0 28.7 21.8 0.76 2.35 35.6 12.2 37.3 2.26 30.7 100.1 4.8 7.8 3.8 8.7 28.8 22.2 0.77 2.30 35.5 12.5 37.7 2.27 31.1 100.5 4.9 3.9 1.3 3.0 25.2 19.2 0.76 2.67 33.2 9.5 5.8 2.1 4.8 26.2 20.2 0.77 2.56 33.8 10.3 7.8 3.7 8.5 26.6 20.8 0.78 2.49 34.0 10.7 3.9 1.2 2.8 23.1 16.6 0.72 3.02 32.3 7.7 5.8 2.0 4.6 24.5 17.4 0.71 2.89 33.3 8.5 7.8 3.6 8.3 24.7 19.5 0.79 2.82 33.2 8.8 • Cooling Performance is tabulated at 80.6 °F DB and 66.2 °F WB entering air. Heating performance tabulated at 68 °F EAT • Tabulated data does not include AHRI/ISO corrections for fan and pump power. • All capacities are expressed in MBH. • Insulated water circuit is recommended for operation below 60 °F EWT. • See performance correction tables for conditions beyond what is listed. • Extrapolation is not permissible. • Blank areas indicate conditions where operation is not recommended. 18 JOHNSON CONTROLS FORM 145.18-EG1 (317) Table 11 - VSCS36 - PSC MOTOR - 1220 CFM WPD COOLING HEATING EWT GPM PSI FT 20 9.5 9.1 21.0 4.8 2.6 6.0 42.4 29.3 0.69 1.68 46.7 7.2 5.4 12.5 42.6 29.0 0.68 1.60 9.5 8.5 19.6 42.8 28.6 0.67 1.58 4.8 2.5 5.8 41.2 30.0 0.73 7.2 5.0 11.5 41.6 29.9 9.5 8.0 18.5 42.0 29.4 4.8 2.3 5.3 39.2 7.2 4.6 10.6 9.5 7.4 17.1 4.8 2.1 7.2 9.5 30 40 50 60 70 80 90 100 110 TC SC SHR KW HR EER HTG KW HE LAT COP 20.1 2.19 14.1 83.3 2.7 25.2 22.8 2.29 16.5 85.3 2.9 46.6 26.6 23.6 2.30 17.2 85.9 3.0 46.7 27.1 24.2 2.31 17.8 86.4 3.1 1.81 45.9 22.7 26.6 2.31 20.2 88.2 3.4 0.72 1.72 46.0 24.1 27.7 2.34 21.1 89.0 3.5 0.70 1.68 46.3 25.0 28.6 2.35 22.0 89.7 3.6 29.0 0.74 1.91 44.3 20.5 30.3 2.35 23.7 91.0 3.8 40.0 29.2 0.73 1.82 44.7 22.0 31.6 2.39 24.9 92.0 3.9 40.5 29.1 0.72 1.77 45.0 22.9 32.1 2.58 24.8 92.4 3.7 4.8 37.3 27.6 0.74 2.18 43.3 17.1 33.2 2.62 25.7 93.2 3.7 4.3 9.9 38.5 28.1 0.73 2.06 44.0 18.7 35.1 2.64 27.6 94.6 3.9 6.9 15.9 39.1 28.5 0.73 2.00 44.4 19.6 36.6 2.65 29.0 95.8 4.0 4.8 2.0 4.6 35.0 26.6 0.76 2.44 41.9 14.3 37.6 2.66 30.0 96.5 4.1 7.2 4.1 9.5 36.7 27.5 0.75 2.38 43.3 15.4 39.7 2.70 31.9 98.1 4.3 9.5 6.6 15.2 37.5 27.7 0.74 2.30 43.9 16.3 40.6 2.72 32.8 98.8 4.4 4.8 1.8 4.2 33.5 26.1 0.78 2.80 41.6 12.0 40.6 2.77 32.6 98.8 4.3 7.2 3.9 9.0 35.0 27.0 0.77 2.74 42.9 12.8 42.7 2.79 34.6 100.4 4.5 9.5 6.3 14.5 35.9 27.1 0.76 2.60 43.3 13.8 43.7 2.80 35.6 101.2 4.6 4.8 1.7 3.9 31.9 25.2 0.79 3.14 41.2 10.2 43.6 2.82 35.4 101.1 4.5 7.2 3.7 8.5 33.2 25.6 0.77 2.89 41.6 11.5 45.4 2.86 37.1 102.5 4.7 9.5 6.0 13.8 34.2 26.1 0.76 2.78 42.2 12.3 46.3 2.88 37.9 103.1 4.7 4.8 1.6 3.7 29.5 23.3 0.79 3.31 39.3 8.9 7.2 3.8 8.8 30.9 24.1 0.78 3.11 40.1 9.9 9.5 5.8 13.4 31.8 24.8 0.78 3.00 40.5 10.6 4.8 1.6 3.7 26.9 21.8 0.81 3.72 38.1 7.2 7.2 3.7 8.5 28.2 22.5 0.80 3.42 38.4 8.2 9.5 5.7 13.1 28.9 22.8 0.79 3.35 38.9 8.6 • Cooling Performance is tabulated at 80.6 °F DB and 66.2 °F WB entering air. Heating performance tabulated at 68 °F EAT • Tabulated data does not include AHRI/ISO corrections for fan and pump power. • All capacities are expressed in MBH. • Insulated water circuit is recommended for operation below 60 °F EWT. • See performance correction tables for conditions beyond what is listed. • Extrapolation is not permissible. • Blank areas indicate conditions where operation is not recommended. JOHNSON CONTROLS 19 FORM 145.18-EG1 (317) Performance Data - EC Motor (ECM) Table 12 - VSCS09 - EC MOTOR (ECM) - 340 CFM WPD COOLING HEATING EWT GPM PSI FT 20 2.6 6.8 15.7 1.3 1.8 4.2 11.3 7.5 0.66 0.40 12.4 2.0 4.1 9.4 11.6 7.8 0.67 0.37 2.6 6.7 15.3 11.9 8.3 0.69 0.36 1.3 1.7 3.8 10.6 7.3 0.68 0.46 2.0 3.7 8.5 10.7 7.4 0.69 2.6 6.0 13.9 11.1 7.9 0.71 1.3 1.5 3.4 10.2 7.2 2.0 3.3 7.6 10.3 2.6 5.4 12.4 10.6 1.3 1.4 3.3 2.0 3.1 2.6 5.1 1.3 1.3 2.0 3.0 2.6 30 40 50 60 70 80 90 100 110 TC SC SHR KW HR EER HTG KW HE LAT COP 5.1 0.54 3.5 81.9 2.8 28.2 6.2 0.56 4.6 84.9 3.3 12.6 31.1 6.6 0.57 4.9 86.0 3.4 12.9 33.2 6.8 0.59 5.0 86.6 3.4 11.9 23.3 7.2 0.58 5.5 87.6 3.7 0.43 11.9 25.0 7.5 0.60 5.7 88.4 3.7 0.41 12.2 27.1 7.9 0.62 6.0 89.5 3.8 0.70 0.51 11.7 19.9 8.3 0.61 6.5 90.6 4.0 7.4 0.71 0.49 11.7 21.2 8.8 0.63 6.9 91.9 4.1 7.8 0.73 0.46 11.9 23.0 9.1 0.64 7.2 92.8 4.1 9.8 7.2 0.73 0.59 11.6 16.5 9.5 0.63 7.6 93.8 4.4 7.3 9.9 7.4 0.74 0.57 11.7 17.4 10.0 0.65 8.0 95.1 4.5 11.8 10.3 7.8 0.75 0.50 11.8 20.6 10.5 0.66 8.5 96.5 4.6 3.1 9.4 6.9 0.73 0.68 11.5 13.9 10.5 0.64 8.6 96.6 4.9 6.9 9.5 7.1 0.74 0.66 11.5 14.4 11.0 0.66 9.0 98.0 4.9 4.9 11.2 9.8 7.5 0.76 0.55 11.4 17.8 11.7 0.68 9.6 99.9 5.1 1.3 1.3 2.9 9.0 6.9 0.76 0.75 11.4 12.1 12.2 0.66 10.2 101.3 5.4 2.0 2.8 6.5 9.1 7.1 0.77 0.72 11.3 12.7 12.5 0.67 10.5 102.1 5.5 2.6 4.6 10.6 9.4 7.3 0.77 0.61 11.2 15.4 12.9 0.68 10.8 103.2 5.6 1.3 1.2 2.8 8.6 6.6 0.76 0.82 11.2 10.5 13.6 0.69 11.5 105.1 5.8 2.0 2.7 6.2 8.7 6.7 0.77 0.77 11.1 11.2 14.3 0.70 12.2 107.0 6.0 2.6 4.4 10.1 8.8 6.9 0.78 0.65 10.8 13.7 14.6 0.71 12.4 107.8 6.1 1.3 1.1 2.5 8.3 6.4 0.77 0.91 11.2 9.1 2.0 2.6 6.0 8.4 6.6 0.78 0.87 11.2 9.7 2.6 4.3 9.9 8.6 6.8 0.79 0.81 11.1 10.6 1.3 1.1 2.5 7.9 6.3 0.79 1.01 11.1 7.9 2.0 2.5 5.8 8.2 6.5 0.79 0.96 11.2 8.5 2.6 4.2 9.7 8.3 6.7 0.80 0.94 11.3 8.8 • Cooling Performance is tabulated at 80.6 °F DB and 66.2 °F WB entering air. Heating performance tabulated at 68 °F EAT • Tabulated data does not include AHRI/ISO corrections for fan and pump power. • All capacities are expressed in MBH. • Insulated water circuit is recommended for operation below 60 °F EWT. • See performance correction tables for conditions beyond what is listed. • Extrapolation is not permissible. • Blank areas indicate conditions where operation is not recommended. 20 JOHNSON CONTROLS FORM 145.18-EG1 (317) Table 13 - VSCS12 - EC MOTOR (ECM) - 430 CFM WPD COOLING HEATING EWT GPM PSI FT 20 3.2 6.5 15.0 1.6 1.7 4.0 15.5 10.6 0.68 0.59 17.2 2.4 3.7 8.5 15.8 11.0 0.69 0.55 3.2 6.3 14.5 16.2 11.4 0.70 0.53 1.6 1.6 3.7 15.1 10.8 0.71 2.4 3.4 7.9 15.5 11.1 3.2 5.9 13.5 15.8 11.4 1.6 1.5 3.5 14.1 2.4 3.2 7.3 3.2 5.4 12.5 1.6 1.4 2.4 3.2 30 40 50 60 70 80 90 100 110 TC SC SHR KW HR EER HTG KW HE LAT COP 7.7 0.75 5.4 84.5 3.0 26.1 8.9 0.83 6.3 87.1 3.1 17.4 28.7 9.1 0.84 6.5 87.6 3.2 17.7 30.7 9.3 0.85 6.7 88.1 3.2 0.65 17.0 23.0 10.0 0.83 7.4 89.5 3.5 0.71 0.61 17.3 25.3 10.4 0.84 7.8 90.4 3.6 0.72 0.58 17.4 27.3 10.6 0.85 8.0 90.9 3.7 10.1 0.71 0.72 16.3 19.7 11.3 0.89 8.5 92.3 3.7 14.5 10.5 0.72 0.65 16.5 22.2 11.7 0.91 8.9 93.1 3.8 15.0 11.0 0.73 0.63 16.9 23.8 12.0 0.92 9.1 93.8 3.8 3.3 13.4 9.7 0.72 0.79 15.8 16.9 12.5 0.88 9.8 94.9 4.2 3.0 6.9 13.8 10.1 0.73 0.74 16.0 18.7 13.0 0.89 10.2 95.9 4.3 5.1 11.8 14.6 10.8 0.74 0.66 16.5 21.9 13.4 0.89 10.6 96.8 4.4 1.6 1.3 3.0 12.7 9.3 0.73 0.92 15.5 13.7 13.7 0.90 10.9 97.4 4.4 2.4 2.8 6.5 13.0 9.7 0.74 0.85 15.6 15.2 14.3 0.91 11.5 98.7 4.6 3.2 4.9 11.3 13.2 9.9 0.75 0.79 15.6 16.6 14.8 0.91 12.0 99.8 4.7 1.6 1.3 3.0 11.7 8.9 0.75 0.97 14.7 12.0 15.2 0.92 12.3 100.7 4.8 2.4 2.7 6.2 12.0 9.3 0.77 0.89 14.7 13.5 15.8 0.94 12.9 102.0 4.9 3.2 4.7 10.8 12.7 10.0 0.79 0.80 15.1 15.7 16.2 0.95 13.3 102.9 5.0 1.6 1.2 2.9 11.2 8.6 0.76 1.09 14.6 10.3 16.7 0.96 13.7 103.9 5.1 2.4 2.6 6.1 11.5 8.9 0.77 1.00 14.6 11.5 17.4 0.97 14.4 105.5 5.2 3.2 4.5 10.4 12.0 9.5 0.79 0.91 14.8 13.2 17.9 0.98 14.8 106.5 5.4 1.6 1.2 2.7 10.3 8.0 0.77 1.17 14.0 8.8 2.4 2.5 5.8 10.7 8.4 0.78 1.11 14.2 9.6 3.2 4.4 10.2 10.8 8.6 0.79 1.06 14.1 10.2 1.6 1.1 2.5 9.7 7.6 0.78 1.28 13.8 7.6 2.4 2.4 5.5 10.1 7.9 0.78 1.23 14.0 8.2 3.2 4.3 9.9 10.3 8.2 0.79 1.18 14.0 8.7 • Cooling Performance is tabulated at 80.6 °F DB and 66.2 °F WB entering air. Heating performance tabulated at 68 °F EAT • Tabulated data does not include AHRI/ISO corrections for fan and pump power. • All capacities are expressed in MBH. • Insulated water circuit is recommended for operation below 60 °F EWT. • See performance correction tables for conditions beyond what is listed. • Extrapolation is not permissible. • Blank areas indicate conditions where operation is not recommended. JOHNSON CONTROLS 21 FORM 145.18-EG1 (317) Performance Data - EC Motor (ECM) (Cont'd) Table 14 - VSCS15 - EC MOTOR (ECM) - 550 CFM WPD COOLING HEATING EWT GPM PSI FT 20 4.0 7.0 16.2 2.0 1.9 4.5 19.1 14.2 0.74 0.56 20.7 3.0 4.1 9.5 19.2 14.6 0.75 0.50 4.0 7.0 16.2 19.3 14.8 0.76 0.45 2.0 1.9 4.3 18.6 14.5 0.77 3.0 4.0 9.1 18.9 14.7 4.0 6.7 15.6 18.8 14.8 2.0 1.8 4.1 17.4 3.0 3.8 8.7 4.0 6.5 14.9 2.0 1.6 3.0 4.0 30 40 50 60 70 80 90 100 110 TC SC SHR KW HR EER HTG KW HE LAT COP 8.3 0.79 5.9 82.0 3.1 34.3 9.2 0.85 6.6 83.5 3.2 20.7 38.9 10.0 0.65 8.1 84.9 4.5 20.6 42.5 10.3 0.87 7.6 85.4 3.5 0.62 20.4 29.9 11.4 0.88 8.7 87.3 3.8 0.77 0.56 20.6 33.8 11.9 0.90 9.1 88.0 3.9 0.78 0.50 20.2 37.3 12.2 0.91 9.4 88.5 3.9 13.2 0.75 0.69 19.4 25.2 12.8 0.91 10.0 89.6 4.1 17.7 13.4 0.75 0.60 19.4 29.3 13.4 0.91 10.6 90.6 4.3 17.8 13.7 0.76 0.56 19.4 32.1 13.8 0.92 10.9 91.3 4.4 3.6 16.4 12.6 0.76 0.75 18.7 21.9 14.6 0.92 11.7 92.5 4.6 3.3 7.7 16.6 12.8 0.76 0.69 18.7 24.0 15.1 0.93 12.2 93.4 4.8 5.7 13.1 16.7 12.9 0.76 0.66 18.7 25.3 15.5 0.94 12.6 94.1 4.8 2.0 1.4 3.3 15.5 12.2 0.78 0.85 18.1 18.3 15.9 0.93 13.0 94.7 5.0 3.0 3.1 7.0 15.7 12.5 0.79 0.80 18.2 19.6 16.5 0.94 13.6 95.8 5.1 4.0 5.2 12.0 15.8 12.6 0.79 0.78 18.2 20.3 17.1 0.95 14.1 96.8 5.3 2.0 1.4 3.2 14.7 11.9 0.80 0.94 17.7 15.7 17.6 0.97 14.6 97.7 5.3 3.0 2.9 6.7 14.9 12.1 0.80 0.90 17.7 16.5 18.1 0.99 15.0 98.5 5.4 4.0 5.0 11.4 15.0 12.2 0.80 0.88 17.8 17.0 18.5 1.02 15.3 99.2 5.3 2.0 1.3 3.0 14.0 11.6 0.82 1.05 17.3 13.4 18.7 1.02 15.5 99.5 5.4 3.0 2.8 6.4 14.3 11.8 0.82 0.99 17.4 14.4 19.1 1.04 15.9 100.2 5.4 4.0 4.7 10.9 14.4 12.0 0.83 0.99 17.5 14.5 19.3 1.04 16.0 100.5 5.4 2.0 1.2 2.8 13.2 11.0 0.83 1.17 17.0 11.3 3.0 2.6 6.0 13.5 11.4 0.84 1.13 17.1 12.0 4.0 4.4 10.2 13.6 11.5 0.84 1.11 17.1 12.3 2.0 1.1 2.6 12.5 10.8 0.86 1.31 16.7 9.5 3.0 2.5 5.8 12.8 11.2 0.87 1.26 16.9 10.1 4.0 4.5 10.3 13.0 11.3 0.87 1.24 16.9 10.4 • Cooling Performance is tabulated at 80.6 °F DB and 66.2 °F WB entering air. Heating performance tabulated at 68 °F EAT • Tabulated data does not include AHRI/ISO corrections for fan and pump power. • All capacities are expressed in MBH. • Insulated water circuit is recommended for operation below 60 °F EWT. • See performance correction tables for conditions beyond what is listed. • Extrapolation is not permissible. • Blank areas indicate conditions where operation is not recommended. 22 JOHNSON CONTROLS FORM 145.18-EG1 (317) Table 15 - VSCS18 - EC MOTOR (ECM) - 685 CFM WPD COOLING HEATING EWT GPM PSI FT 20 4.8 7.5 17.3 2.4 2.0 4.7 22.5 15.4 0.68 0.66 24.3 3.6 4.3 9.9 22.6 15.5 0.68 0.63 4.8 7.3 16.8 22.9 15.9 0.69 0.60 2.4 1.9 4.5 21.6 15.2 0.70 3.6 4.1 9.5 21.8 15.6 4.8 7.0 16.1 22.2 16.1 2.4 1.9 4.3 20.8 3.6 3.9 9.1 4.8 6.7 15.5 2.4 1.6 3.6 4.8 30 40 50 60 70 80 90 100 110 TC SC SHR KW HR EER HTG KW HE LAT COP 11.1 1.21 7.5 83.0 2.7 33.9 12.7 1.21 9.0 85.2 3.1 24.3 35.7 13.2 1.21 9.5 85.9 3.2 24.5 38.1 13.6 1.23 9.9 86.4 3.2 0.80 23.8 27.1 14.3 1.22 10.6 87.3 3.4 0.71 0.75 23.9 29.2 14.6 1.22 10.9 87.8 3.5 0.72 0.71 24.2 31.2 15.2 1.24 11.4 88.5 3.6 15.0 0.72 0.90 23.4 23.1 16.3 1.23 12.6 90.1 3.9 21.8 16.0 0.73 0.83 24.2 26.2 17.0 1.24 13.3 91.0 4.0 21.5 15.8 0.73 0.79 23.8 27.2 17.7 1.24 13.9 91.9 4.2 3.8 20.0 14.7 0.73 1.05 23.1 19.0 18.7 1.24 14.9 93.2 4.4 3.5 8.0 20.7 15.2 0.73 0.98 23.6 21.1 19.5 1.25 15.7 94.3 4.6 5.9 13.6 21.1 15.7 0.74 0.93 23.8 22.6 20.1 1.29 16.1 95.1 4.6 2.4 1.5 3.5 19.1 14.4 0.75 1.21 22.8 15.9 20.9 1.25 17.1 96.2 4.9 3.6 3.2 7.3 19.4 14.8 0.76 1.13 22.8 17.1 21.8 1.27 17.9 97.5 5.0 4.8 5.4 12.5 19.7 15.2 0.77 1.10 23.0 17.9 22.5 1.30 18.5 98.4 5.1 2.4 1.4 3.3 18.1 13.6 0.75 1.36 22.3 13.3 22.9 1.27 19.1 99.0 5.3 3.6 3.0 7.0 18.5 14.3 0.77 1.28 22.4 14.4 23.9 1.29 20.0 100.3 5.4 4.8 5.2 11.9 18.9 15.0 0.79 1.18 22.4 16.0 24.9 1.31 20.9 101.7 5.6 2.4 1.4 3.1 17.3 13.4 0.77 1.55 22.1 11.1 24.6 1.28 20.7 101.3 5.6 3.6 2.9 6.6 17.7 13.9 0.78 1.46 22.3 12.1 25.5 1.31 21.5 102.5 5.7 4.8 4.9 11.3 18.1 14.3 0.79 1.37 22.3 13.2 27.4 1.33 23.3 105.0 6.0 2.4 1.3 3.0 16.1 12.6 0.78 1.74 21.5 9.2 3.6 2.8 6.5 16.5 13.0 0.78 1.64 21.7 10.1 4.8 4.8 11.1 17.3 13.7 0.79 1.59 22.3 10.9 2.4 1.2 2.8 15.2 11.9 0.78 1.99 21.5 7.6 3.6 2.7 6.2 15.7 12.5 0.79 1.88 21.6 8.4 4.8 4.7 10.8 16.5 13.3 0.80 1.82 22.3 9.1 • Cooling Performance is tabulated at 80.6 °F DB and 66.2 °F WB entering air. Heating performance tabulated at 68 °F EAT • Tabulated data does not include AHRI/ISO corrections for fan and pump power. • All capacities are expressed in MBH. • Insulated water circuit is recommended for operation below 60 °F EWT. • See performance correction tables for conditions beyond what is listed. • Extrapolation is not permissible. • Blank areas indicate conditions where operation is not recommended. JOHNSON CONTROLS 23 FORM 145.18-EG1 (317) Performance Data - EC Motor (ECM) (Cont'd) Table 16 - VSCS24 - EC MOTOR (ECM) - 850 CFM WPD COOLING HEATING EWT GPM PSI FT 20 6.2 6.6 15.2 3.1 1.7 4.0 29.5 19.5 0.66 1.04 32.3 4.6 3.6 8.3 29.7 20.3 0.68 1.01 6.2 6.3 14.4 29.9 20.7 0.69 0.97 3.1 1.6 3.6 29.3 20.0 0.68 4.6 3.3 7.5 29.4 20.4 6.2 5.6 13.0 29.5 20.7 3.1 1.4 3.2 28.4 4.6 2.9 6.7 6.2 5.0 11.6 3.1 1.3 4.6 6.2 30 40 50 60 70 80 90 100 110 TC SC SHR KW HR EER HTG KW HE LAT COP 13.6 1.56 9.0 82.8 2.6 28.4 15.4 1.57 10.8 84.8 2.9 32.5 29.6 16.9 1.58 12.2 86.4 3.1 32.5 30.9 17.2 1.59 12.5 86.8 3.2 1.15 32.5 25.4 18.5 1.60 13.8 88.2 3.4 0.69 1.10 32.4 26.8 19.9 1.63 15.1 89.7 3.6 0.70 1.04 32.3 28.5 20.4 1.65 15.5 90.2 3.6 19.7 0.69 1.25 32.0 22.7 21.6 1.65 16.7 91.6 3.9 28.6 20.1 0.70 1.18 31.9 24.2 22.7 1.72 17.6 92.8 3.9 28.7 20.5 0.71 1.12 31.9 25.7 23.5 1.74 18.3 93.6 4.0 3.0 27.3 19.5 0.71 1.44 31.5 19.0 24.4 1.72 19.2 94.6 4.2 2.7 6.2 27.5 19.9 0.72 1.32 31.4 20.8 25.8 1.73 20.6 96.1 4.4 4.7 10.8 27.8 20.4 0.73 1.21 31.3 22.9 27.1 1.77 21.8 97.5 4.5 3.1 1.3 2.9 26.2 19.0 0.72 1.63 31.1 16.1 27.2 1.75 21.9 97.7 4.6 4.6 2.6 6.0 26.7 19.3 0.72 1.52 31.2 17.6 28.9 1.76 23.6 99.5 4.8 6.2 4.5 10.4 27.1 20.1 0.74 1.42 31.3 19.1 30.5 1.80 25.0 101.2 5.0 3.1 1.2 2.8 24.6 18.0 0.73 1.83 30.1 13.4 29.9 1.79 24.5 100.6 4.9 4.6 2.5 5.8 25.2 18.5 0.73 1.72 30.4 14.6 32.0 1.82 26.5 102.9 5.2 6.2 4.3 10.0 25.8 19.2 0.74 1.66 30.8 15.6 33.3 1.87 27.6 104.3 5.2 3.1 1.1 2.5 23.0 16.8 0.73 2.07 29.3 11.1 33.5 1.87 27.8 104.5 5.3 4.6 2.4 5.5 23.4 17.4 0.74 1.94 29.4 12.1 35.3 1.96 29.3 106.5 5.3 6.2 4.2 9.7 23.9 18.2 0.76 1.81 29.4 13.2 36.5 2.00 30.4 107.8 5.3 3.1 1.1 2.5 21.5 16.4 0.76 2.34 28.8 9.2 4.6 2.3 5.3 21.9 16.7 0.76 2.20 28.7 10.0 6.2 4.2 9.7 22.4 17.3 0.77 2.09 28.8 10.7 3.1 1.0 2.3 20.1 15.5 0.77 2.62 28.3 7.7 4.6 2.3 5.3 20.6 15.9 0.77 2.49 28.4 8.3 6.2 4.1 9.5 20.9 16.3 0.78 2.36 28.3 8.8 • Cooling Performance is tabulated at 80.6 °F DB and 66.2 °F WB entering air. Heating performance tabulated at 68 °F EAT • Tabulated data does not include AHRI/ISO corrections for fan and pump power. • All capacities are expressed in MBH. • Insulated water circuit is recommended for operation below 60 °F EWT. • See performance correction tables for conditions beyond what is listed. • Extrapolation is not permissible. • Blank areas indicate conditions where operation is not recommended. 24 JOHNSON CONTROLS FORM 145.18-EG1 (317) Table 17 - VSCS30 - EC MOTOR (ECM) - 850 CFM WPD COOLING HEATING EWT GPM PSI FT 20 3.9 5.6 12.9 3.9 1.5 3.5 35.3 24.1 0.68 1.24 38.8 5.8 3.1 7.2 35.8 24.8 0.69 1.22 7.8 5.4 12.5 36.1 25.4 0.70 1.19 3.9 1.4 3.2 35.7 24.8 0.69 5.8 2.9 6.6 36.2 25.8 7.8 5.0 11.4 36.3 26.2 3.9 1.2 2.9 34.5 5.8 2.6 6.0 7.8 4.5 10.4 3.9 1.2 5.8 7.8 30 40 50 60 70 80 90 100 110 TC SC SHR KW HR EER HTG KW HE LAT COP 16.9 1.76 11.6 82.6 2.8 28.5 19.9 1.79 14.5 85.2 3.3 39.2 29.4 20.6 1.81 15.1 85.8 3.3 39.5 30.2 21.4 1.82 15.9 86.5 3.5 1.32 39.6 27.1 21.5 1.85 15.8 86.5 3.4 0.71 1.28 39.9 28.3 22.4 1.90 16.6 87.3 3.5 0.72 1.24 39.8 29.2 23.3 1.96 17.3 88.1 3.5 24.9 0.72 1.38 38.5 24.9 24.8 1.94 18.9 89.4 3.7 34.9 25.6 0.73 1.34 38.8 25.9 26.1 2.02 19.9 90.5 3.8 35.0 26.0 0.74 1.32 38.8 26.5 28.1 2.08 21.7 92.2 4.0 2.8 33.4 24.5 0.73 1.58 38.1 21.1 29.0 2.01 22.9 93.0 4.2 2.5 5.8 33.8 25.2 0.74 1.54 38.4 21.9 30.6 2.07 24.2 94.4 4.3 4.3 10.0 33.9 25.2 0.74 1.51 38.3 22.4 31.8 2.10 25.3 95.4 4.4 3.9 1.2 2.7 31.7 23.2 0.73 1.77 37.0 17.9 32.3 2.06 26.0 95.8 4.6 5.8 2.4 5.6 32.2 23.9 0.74 1.70 37.3 18.9 34.0 2.11 27.5 97.3 4.7 7.8 4.2 9.6 32.8 24.7 0.75 1.77 38.2 18.6 35.3 2.11 28.8 98.4 4.9 3.9 1.1 2.6 30.1 22.4 0.74 2.01 36.3 15.0 34.4 2.07 28.1 97.7 4.9 5.8 2.3 5.4 30.7 23.1 0.75 1.93 36.6 15.9 35.6 2.12 29.1 98.7 4.9 7.8 4.0 9.3 31.5 24.0 0.76 2.01 37.7 15.6 36.5 2.12 29.9 99.4 5.0 3.9 1.0 2.4 28.6 21.5 0.75 2.25 35.6 12.7 35.9 2.09 29.5 99.0 5.0 5.8 2.2 5.0 29.2 22.3 0.76 2.21 36.0 13.2 36.8 2.13 30.2 99.7 5.1 7.8 3.8 8.7 29.3 22.6 0.77 2.16 36.0 13.5 37.2 2.13 30.6 100.1 5.1 3.9 1.3 3.0 25.7 19.6 0.76 2.53 33.7 10.1 5.8 2.1 4.8 26.7 20.7 0.77 2.42 34.3 11.0 7.8 3.7 8.5 27.1 21.2 0.78 2.35 34.5 11.5 3.9 1.2 2.8 23.6 17.1 0.72 2.89 32.7 8.2 5.8 2.0 4.6 25.0 17.9 0.71 2.76 33.7 9.1 7.8 3.6 8.3 25.1 20.0 0.79 2.69 33.6 9.4 • Cooling Performance is tabulated at 80.6 °F DB and 66.2 °F WB entering air. Heating performance tabulated at 68 °F EAT • Tabulated data does not include AHRI/ISO corrections for fan and pump power. • All capacities are expressed in MBH. • Insulated water circuit is recommended for operation below 60 °F EWT. • See performance correction tables for conditions beyond what is listed. • Extrapolation is not permissible. • Blank areas indicate conditions where operation is not recommended. JOHNSON CONTROLS 25 FORM 145.18-EG1 (317) Performance Data - EC Motor (ECM) (Cont'd) Table 18 - VSCS36 - EC MOTOR (ECM) - 850 CFM WPD COOLING HEATING EWT GPM PSI FT 20 9.5 9.1 21.0 4.8 2.6 6.0 42.9 29.8 0.69 1.52 47.2 7.2 5.4 12.5 43.2 29.5 0.68 1.44 9.5 8.5 19.6 43.3 29.2 0.67 1.42 4.8 2.5 5.8 41.7 30.6 0.73 7.2 5.0 11.5 42.1 30.5 9.5 8.0 18.5 42.5 29.9 4.8 2.3 5.3 39.8 7.2 4.6 10.6 9.5 7.4 17.1 4.8 2.1 7.2 9.5 30 40 50 60 70 80 90 100 110 TC SC SHR KW HR EER HTG KW HE LAT COP 19.6 2.03 13.5 82.8 2.8 28.3 22.3 2.12 15.9 84.9 3.1 47.2 30.0 23.1 2.14 16.7 85.5 3.2 47.2 30.6 23.7 2.15 17.2 85.9 3.2 1.65 46.5 25.2 26.1 2.14 19.6 87.8 3.6 0.72 1.56 46.6 27.0 27.1 2.17 20.6 88.6 3.7 0.70 1.52 46.8 28.0 28.1 2.18 21.5 89.3 3.8 29.6 0.74 1.75 44.9 22.7 29.8 2.19 23.2 90.6 4.0 40.5 29.7 0.73 1.66 45.3 24.4 31.1 2.23 24.3 91.6 4.1 41.0 29.7 0.72 1.61 45.6 25.5 31.6 2.41 24.2 91.9 3.8 4.8 37.8 28.2 0.74 2.02 43.8 18.7 32.7 2.46 25.2 92.8 3.9 4.3 9.9 39.0 28.6 0.73 1.89 44.6 20.6 34.6 2.48 27.0 94.2 4.1 6.9 15.9 39.6 29.1 0.73 1.83 45.0 21.6 36.1 2.49 28.4 95.4 4.2 4.8 2.0 4.6 35.5 27.1 0.76 2.28 42.4 15.6 37.1 2.50 29.4 96.1 4.3 7.2 4.1 9.5 37.2 28.1 0.75 2.22 43.9 16.8 39.2 2.54 31.4 97.7 4.5 9.5 6.6 15.2 38.0 28.3 0.74 2.14 44.4 17.8 40.1 2.56 32.2 98.4 4.6 4.8 1.8 4.2 34.0 26.7 0.78 2.64 42.1 12.9 40.1 2.61 32.0 98.4 4.5 7.2 3.9 9.0 35.5 27.5 0.77 2.57 43.4 13.8 42.2 2.63 34.1 100.0 4.7 9.5 6.3 14.5 36.4 27.7 0.76 2.44 43.8 14.9 43.2 2.64 35.0 100.7 4.8 4.8 1.7 3.9 32.4 25.8 0.79 2.98 41.7 10.9 43.1 2.66 34.9 100.7 4.7 7.2 3.7 8.5 33.7 26.1 0.77 2.73 42.2 12.4 44.9 2.70 36.5 102.0 4.9 9.5 6.0 13.8 34.7 26.7 0.76 2.62 42.8 13.3 45.8 2.72 37.4 102.7 4.9 4.8 1.6 3.7 30.0 23.9 0.79 3.15 39.9 9.5 7.2 3.8 8.8 31.4 24.6 0.78 2.95 40.6 10.6 9.5 5.8 13.4 32.3 25.3 0.78 2.84 41.1 11.4 4.8 1.6 3.7 27.5 22.3 0.81 3.56 38.7 7.7 7.2 3.7 8.5 28.7 23.1 0.80 3.26 38.9 8.8 9.5 5.7 13.1 29.4 23.4 0.79 3.19 39.4 9.2 • Cooling Performance is tabulated at 80.6 °F DB and 66.2 °F WB entering air. Heating performance tabulated at 68 F EAT • Tabulated data does not include AHRI/ISO corrections for fan and pump power. • All capacities are expressed in MBH. • Insulated water circuit is recommended for operation below 60 °F EWT. • See performance correction tables for conditions beyond what is listed. • Extrapolation is not permissible. • Blank areas indicate conditions where operation is not recommended. 26 JOHNSON CONTROLS FORM 145.18-EG1 (317) Performance Data Table 19 - ANTIFREEZE CORRECTION ANTIFREEZE CONCENTRATION ETHYLENE GLYCOL PROPYLENE GLYCOL METHANOL 5% 10% 15% 20% 25% 30% 40% TC, SC 0.998 0.995 0.993 0.991 0.989 0.987 0.984 HTG 0.995 0.990 0.985 0.980 0.974 0.969 0.964 WPD 1.040 1.055 1.080 1.105 1.135 1.165 1.210 TC, SC 0.995 0.992 0.987 0.983 0.979 0.975 0.970 HTG 0.989 0.982 0.975 0.967 0.958 0.951 0.943 WPD 1.035 1.055 1.100 1.145 1.200 1.260 1.320 TC, SC 0.999 0.995 0.990 0.986 0.982 0.980 0.978 HTG 0.989 0.985 0.979 0.971 0.963 0.954 0.946 WPD 1.050 1.072 1.094 1.116 1.140 1.165 1.196 Table 20 - AIRFLOW CORRECTION COOLING AIRFLOW % HEATING TC SC KW HR HTG KW HE 70 0.931 0.847 0.964 0.946 0.942 1.075 0.940 75 0.941 0.872 0.969 0.956 0.953 1.059 0.949 80 0.950 0.896 0.979 0.961 0.960 1.039 0.958 85 0.966 0.923 0.983 0.971 0.970 1.023 0.969 90 0.977 0.948 0.989 0.981 0.979 1.015 0.979 95 0.989 0.974 0.995 0.990 0.989 1.007 0.989 100 1.000 1.000 1.000 1.000 1.000 1.000 1.000 105 1.008 1.025 1.006 1.010 1.009 0.994 1.010 110 1.018 1.048 1.013 1.017 1.019 0.992 1.018 115 1.026 1.070 1.019 1.026 1.029 0.991 1.028 Table 21 - COOLING PERFORMANCE CORRECTION EAT DB (F) - SC EAT WB (F) TC 60 0.845 65 0.948 66.2 1 0.539 70 1.061 75 1.162 70 75 80.6 0.86 1.1 0.628 0.865 HR 85 90 95 1.305 S S S 0.904 1.082 1.312 S S 0.979 0.777 1 1.22 1.475 S 1 0.631 0.855 1.081 1.331 1.543 1.039 0.618 0.848 1.09 1.296 1.107 S = Sensible cooling is equal to Total Cooling Table 22 - HEATING PERFORMANCE CORRECTION EAT DB (F) HTG KW HE 45 1.101 0.785 1.162 50 1.080 0.832 1.125 55 1.059 0.878 1.079 60 1.039 0.926 1.064 65 1.019 0.960 1.023 68 1.000 1.000 1.000 70 0.990 1.028 0.983 75 0.974 1.064 0.957 80 0.951 1.111 0.918 JOHNSON CONTROLS 27 FORM 145.18-EG1 (317) Riser Selection and Data RISER APPLICATION AND SIZING Technical information on heat transfer, fluid flow and pipe sizing can be found in the ASHRAE Fundamentals Handbook and various other technical documents and publications. Some of the factors affecting riser application and sizing are noise, tube erosion and economics. The Friction Loss For Risers chart (next page) displays riser tube diameter sizes as a function of flow (GPM), friction loss and water velocity. For maximum riser velocity on pressure drop per 100 ft., refer to ASHRAE 2001 Fundamentals 35.3 Table 6 for Riser Sizing. Riser sizes can be of a single diameter on low rise buildings, or varying sizes on medium to high rise buildings. Generally, riser copper type, size, length and insulation thickness are determined by the location of the unit in the building. Risers are available in Type-M or Type-L copper, varying diameters from 3/4" to 3", and with either 1/2" or 3/4" thick closed cell foam insulation. Condensate risers are available in Type-M copper, varying diameters from 3/4" to 1 1/4", and with 3/8" thick closed cell foam insulation. RISER EXPANSION Generally, in medium to high rise buildings, allowance must be made for pipe expansion. Model VSCS vertical stacked water source heat pumps are furnished with hoses which act as expansion loops integral to the unit. The hose will allow for +/- 1½" of riser expansion and contraction. Additional expansion compensation must be made in the riser system in the field where movement is expected to exceed the factory allowances. The Allowable Riser Lengths Between System Expansion Loops chart displays the expansion characteristics of risers compared to water temperature difference. Technical information on pipe expansion, contraction and anchoring can be found in the ASHRAE HVAC Systems and Equipment Handbook and various other technical documents and publications. 28 JOHNSON CONTROLS FORM 145.18-EG1 (317) Blower Performance Table 23 - PSC STANDARD BLOWER PERFORMANCE (CFM) UNIT SIZE RATED CFM MIN. CFM 09 340 220 12 430 290 15 550 335 18 685 430 24 850 575 30 1075 36 1220 700 840 EXTERNAL STATIC PRESSURE (IN W.G.) MOTOR SPEED 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5 HIGH 340 330 320 310 300 285 270 255 240 225 - LOW 255 250 240 230 220 210 - - - - - HIGH 445 435 425 415 400 385 370 355 340 320 295 LOW 350 345 335 325 315 305 290 - - - - HIGH 580 570 560 550 535 520 505 485 465 445 425 LOW 385 380 375 370 365 355 345 335 - - - HIGH 700 690 675 660 635 615 595 575 550 525 495 LOW 450 445 440 435 430 425 - - - - - HIGH 880 855 835 815 795 770 740 710 680 650 615 LOW 715 710 705 690 670 650 630 605 580 - - HIGH 1115 1100 1075 1050 1020 990 960 930 895 850 800 LOW 965 960 950 935 915 895 870 840 810 780 745 HIGH 1230 1200 1170 1140 1110 1075 1040 1000 960 915 870 LOW 1115 1100 1075 1050 1020 990 960 930 895 855 805 Table 24 - PSC HIGH STATIC BLOWER PERFORMANCE (CFM) UNIT RATED MIN. MOTOR SIZE CFM CFM SPEED 09 340 220 12 430 290 15 550 335 18 685 430 24 850 575 30 1075 700 36 1220 840 HIGH LOW HIGH LOW HIGH LOW HIGH LOW HIGH LOW HIGH LOW HIGH LOW EXTERNAL STATIC PRESSURE (IN W.G.) 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5 0.55 0.6 375 370 360 350 340 330 315 300 285 265 245 220 330 320 310 300 290 280 270 255 240 225 485 475 465 455 440 425 410 395 380 360 340 315 390 385 380 370 360 350 335 320 305 665 650 635 615 595 575 555 540 520 500 475 450 420 580 570 560 550 535 520 505 485 465 445 425 400 375 750 735 715 695 675 655 630 605 580 555 525 495 465 670 655 640 625 605 585 560 535 510 485 460 435 990 970 950 930 910 890 865 845 820 795 770 740 710 795 785 775 760 745 730 715 695 675 655 630 605 580 1180 1170 1160 1145 1130 1110 1090 1070 1050 1025 1000 970 940 985 980 975 970 960 950 940 935 920 905 895 875 850 1340 1320 1295 1270 1245 1220 1190 1160 1130 1100 1070 1040 1010 1180 1170 1160 1145 1130 1110 1090 1070 1050 1025 1000 970 940 0.65 0.7 0.75 0.8 395 350 435 680 910 825 980 910 370 650 875 795 945 875 340 615 840 765 910 840 575 800 730 870 800 NOTE: 1. All airflow ratings are at lowest voltage rating of dual rating (i.e., 208 volt). 2. Airflow ratings include resistance of wet coil and clean air filters. JOHNSON CONTROLS 29 FORM 145.18-EG1 (317) Blower Performance (Cont'd) Table 25 - ECM STANDARD BLOWER PERFORMANCE (CFM) UNIT SIZE RATED CFM MIN. CFM 09 340 180 12 430 236 15 550 268 18 685 396 24 850 574 30 1075 718 36 1220 861 EXTERNAL STATIC PRESSURE (IN W.G.) MOTOR SPEED 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5 High 342 317 292 276 259 247 236 228 220 214 207 Low 278 252 226 212 198 189 180 - - - - High 463 431 399 378 356 340 324 317 310 299 289 Low 342 317 292 276 259 247 236 - - - - High 600 567 534 500 466 445 424 396 367 340 312 Low 495 447 399 372 346 307 268 - - - - High 760 726 693 667 642 615 587 574 561 529 497 Low 600 567 534 500 466 445 424 396 - - - High 891 863 835 809 784 757 730 689 648 601 554 Low 760 726 693 667 642 615 587 574 - - - High 1131 1105 1079 1058 1037 1016 994 972 949 934 918 Low 918 894 870 852 835 808 781 762 743 718 - High 1265 1235 1206 1184 1163 1141 1118 1085 1051 1008 965 Low 1065 1037 1009 987 965 949 934 910 886 874 861 Table 26 - ECM HIGH STATIC BLOWER PERFORMANCE (CFM) UNIT RATED MIN. MOTOR SIZE CFM CFM SPEED 09 340 220 12 430 290 15 550 335 18 685 430 24 850 575 30 1075 700 36 1220 840 30 High Low High Low High Low High Low High Low High Low High Low EXTERNAL STATIC PRESSURE (IN W.G.) 0 0.05 411 342 554 463 659 600 891 760 1002 866 1265 1065 1462 1265 382 317 529 431 623 567 863 726 971 827 1235 1037 1418 1235 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5 0.55 0.6 0.65 0.7 0.75 354 334 315 300 286 279 272 263 292 276 259 247 236 228 220 504 477 451 430 408 393 378 360 399 378 356 340 324 317 310 299 587 564 541 511 482 462 441 419 534 500 466 445 424 396 367 340 835 809 784 757 730 689 648 601 693 667 642 615 587 574 561 529 940 912 883 854 826 800 774 749 789 762 735 708 682 659 636 612 1206 1184 1163 1141 1118 1085 1051 1008 1009 987 965 949 934 910 886 874 1375 1331 1287 1241 1194 1153 1112 1053 1206 1184 1163 1141 1118 1085 1051 1008 254 341 290 397 312 554 497 724 587 965 861 994 965 242 330 372 518 469 698 571 913 839 964 913 231 319 346 482 441 671 861 818 934 861 220 300 320 446 412 643 808 903 - 408 615 756 872 - 586 701 840 - JOHNSON CONTROLS FORM 145.18-EG1 (317) Electrical Data Table 27 - PSC - STANDARD BLOWER - 208/230 VOLT COMPRESSOR UNIT SIZE SUPPLY VOLTAGE QTY 09 12 15 18 24 30 36 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 1 1 1 1 1 1 1 @ @ @ @ @ @ @ BLOWER RLA LRA HP FLA MIN. CCT. AMPACITY 3.7 4.7 5.6 9.0 12.8 14.1 16.7 22.0 25.0 29.0 48.0 58.3 73.0 79.0 0.10 0.10 0.17 0.17 0.25 0.33 0.50 0.8 0.8 1.2 1.2 1.5 2.6 3.2 5.43 6.68 8.20 12.45 17.50 20.23 24.08 MAX FUSE / CCT. BKR. AMP 15 15 15 20 30 30 40 Table 28 - PSC - HI STATIC BLOWER - 208/230 VOLT COMPRESSOR UNIT SIZE SUPPLY VOLTAGE QTY 09 12 15 18 24 30 36 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 1 1 1 1 1 1 1 @ @ @ @ @ @ @ BLOWER RLA LRA HP FLA MIN. CCT. AMPACITY 3.7 4.7 5.6 9.0 12.8 14.1 16.7 22.0 25.0 29.0 48.0 58.3 73.0 79.0 0.10 0.17 0.17 0.25 0.33 0.33 0.50 0.8 1.2 1.2 1.5 2.6 2.6 3.2 5.43 7.08 8.20 12.75 18.60 20.23 24.08 MAX FUSE / CCT. BKR. AMP 15 15 15 20 30 30 40 Table 29 - PSC - STANDARD BLOWER - 265 VOLT SUPPLY COMPRESSOR BLOWER MAX FUSE / CCT. BKR. AMP RLA LRA HP FLA MIN. CCT. AMPACITY @ 3.4 23.0 0.10 0.7 4.95 15 1 @ 4.8 26.3 0.10 0.7 6.70 15 1 @ 5.0 28.0 0.17 0.8 7.05 15 265/1/60 1 @ 7.1 43.0 0.17 0.8 9.68 15 24 265/1/60 1 @ 9.6 54.0 0.25 1.3 13.30 20 30 265/1/60 1 @ 11.2 60.0 0.33 1.9 15.90 25 36 265/1/60 1 @ 13.5 72.0 0.50 2.2 19.08 30 UNIT SIZE VOLTAGE QTY 09 265/1/60 1 12 265/1/60 15 265/1/60 18 Table 30 - PSC - HI STATIC BLOWER - 265 VOLT COMPRESSOR UNIT SIZE SUPPLY VOLTAGE QTY 09 12 15 18 24 30 36 265/1/60 265/1/60 265/1/60 265/1/60 265/1/60 265/1/60 265/1/60 1 1 1 1 1 1 1 JOHNSON CONTROLS @ @ @ @ @ @ @ BLOWER RLA LRA HP FLA MIN. CCT. AMPACITY 3.4 4.8 5.0 7.1 9.6 11.2 13.5 23.0 26.3 28.0 43.0 54.0 60.0 72.0 0.10 0.17 0.25 0.25 0.33 0.33 0.50 0.7 0.8 1.3 1.3 1.9 1.9 2.2 4.95 6.80 7.55 10.18 13.90 15.90 19.08 MAX FUSE / CCT. BKR. AMP 15 15 15 15 20 25 30 31 FORM 145.18-EG1 (317) Electrical Data (Cont'd) Table 31 - ECM - STANDARD BLOWER - 208/230 VOLT COMPRESSOR UNIT SIZE SUPPLY VOLTAGE QTY 09 12 15 18 24 30 36 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 1 1 1 1 1 1 1 @ @ @ @ @ @ @ BLOWER RLA LRA HP FLA MIN. CCT. AMPACITY MAX FUSE / CCT. BKR. AMP 3.7 4.7 5.6 9.0 12.8 14.1 16.7 22.0 25.0 29.0 48.0 58.3 73.0 79.0 0.33 0.33 0.33 0.33 0.33 0.50 0.50 1.0 1.0 2.0 2.0 2.0 2.4 2.4 5.63 6.88 9.00 13.25 18.00 20.03 23.28 15 15 15 20 30 30 35 Table 32 - ECM - OPTIONAL HI-STATIC BLOWER - 208/230 VOLT UNIT SIZE 09 12 15 18 24 30 36 SUPPLY VOLTAGE 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 QTY 1 1 1 1 1 1 1 COMPRESSOR RLA @ 3.7 @ 4.7 @ 5.6 @ 9.0 @ 12.8 @ 14.1 @ 16.7 LRA 22.0 25.0 29.0 48.0 58.3 73.0 79.0 BLOWER HP FLA 0.33 1.0 0.33 1.0 0.33 2.0 0.33 2.0 0.33 2.0 0.50 2.4 0.50 2.4 MIN. CCT. AMPACITY 5.63 6.88 9.00 13.25 18.00 20.03 23.28 MAX FUSE / CCT. BKR. AMP 15 15 15 20 30 30 35 LRA 23.0 26.3 28.0 43.0 54.0 60.0 72.0 BLOWER HP FLA 0.33 1.0 0.33 1.0 0.33 2.0 0.33 2.0 0.33 2.0 0.50 2.4 0.50 2.4 MIN. CCT. AMPACITY 5.25 7.00 8.25 10.88 14.00 16.40 19.28 MAX FUSE / CCT. BKR. AMP 15 15 15 15 20 25 30 BLOWER HP FLA 0.33 1.0 0.33 1.0 0.33 2.0 0.33 2.0 0.33 2.0 0.50 2.4 0.50 2.4 MIN. CCT. AMPACITY 5.25 7.00 8.25 10.88 14.00 16.40 19.28 MAX FUSE / CCT. BKR. AMP 15 15 15 15 20 25 30 Table 33 - ECM - STANDARD BLOWER - 265 VOLT UNIT SIZE 09 12 15 18 24 30 36 SUPPLY VOLTAGE 265/1/60 265/1/60 265/1/60 265/1/60 265/1/60 265/1/60 265/1/60 QTY 1 1 1 1 1 1 1 COMPRESSOR RLA @ 3.4 @ 4.8 @ 5.0 @ 7.1 @ 9.6 @ 11.2 @ 13.5 Table 34 - ECM - OPTIONAL HI-STATIC BLOWER - 265 VOLT UNIT SIZE 09 12 15 18 24 30 36 32 SUPPLY VOLTAGE 265/1/60 265/1/60 265/1/60 265/1/60 265/1/60 265/1/60 265/1/60 QTY 1 1 1 1 1 1 1 COMPRESSOR RLA @ 3.4 @ 4.8 @ 5.0 @ 7.1 @ 9.6 @ 11.2 @ 13.5 LRA 23.0 26.3 28.0 43.0 54.0 60.0 72.0 JOHNSON CONTROLS FORM 145.18-EG1 (317) Dimensional Data Ca bi net Di mens i ons OPTIONAL FRONT SUPPLY OPENI NG OPTIONAL 24V CONNECTI ON FOR SURFACE-MOUNT/ REMOTE MOUNTED THERMOSTAT 7/ 8" CONTROL ENTRANCE 7 A B 09-12 15-24 30-36 17 20 24 17 20 24 SWI TCH PLATE w/ 2-SPD FAN SWITCH (OPTI ONAL: DI SCONNECT/ FUSES, ADA MOLEX CONN.) ELECTRICAL BOX 80" or 88" Model SERVICE HOSES PASS-THRU 4” 50 LEFT RISER OPENING KNOCK-OUTS (ALL 3 SIDES) BACK 4-1/4” 48 RETURN AIR FLANGE STANDARD 1 IN. CHASSIS SERVICE PANEL 4-1/4” 4-1/4” R R R.A Fl a nge Wi dth 16 19 23 D 4-1/4” OPTIONAL RISER COVER SHOWN S R A/2 S S D D 13 1/4” RIGHT 6 3 4.5 B LEFT VI EW A FRONT VI EW TOP VIEW FRONT 4-5/16” R - RETURN RISER S - SUPPLY RISER D - DRAIN RISER Note: 1) Supply,Return, and Condensate riser openings are pre-punched on all sides and field convertible. Cut tabs to remove knock -out. 2) Supply and Return openings are 4” x 2.5”. During riser installation, ensure stub-out is centered in supply and return openings. 3) Condensate P-trap is accessible from front by removing bottom cover plate. 4) Riser and shut-off location is measured from base of cabinet and does not include stand height. LD19318 JOHNSON CONTROLS 33 FORM 145.18-EG1 (317) Dimensional Data (Cont'd) Note: 13. Riser shut-off valve is measured from base of cabinet and does not include stand height. 34 LD19330 JOHNSON CONTROLS FORM 145.18-EG1 (317) CABINET DIMENSIONS MODEL A B C 9-12 17 8 12 15-24 20 12 14 30-36 24 16 18 1. Optional Fresh Air option comes with 4-1/4” R.A flange. 2. Optional front supply opening comes with 4-1/4” duct flange. 3. All other openings come with standard 1” duct flange. 4. Left and Right hand versions shown. JOHNSON CONTROLS 35 FORM 145.18-EG1 (317) Dimensional Data (Cont'd) * Cut away view for standard cabinet with no stand. Add stand height to cabinet to obtain correct dimension of R/A panel from floor. ALL DIMENSIONS ARE IN INCHES MODEL Note: 1) Dimensions shown do not include optional stand height. VSCS09/12 A B C D ROUGH-IN ROUGH-IN WIDTH HEIGHT 22.75 20.50 16.25 18.50 20.75 52.75 VSCS15/18/24 25.75 23.50 19.25 21.50 23.75 52.75 27.75 52.75 VSCS30/36 29.75 27.50 23.25 25.50 NOTES: -Acoustic Panel powder coated in ‘Appliance White’ -Acoustic Panel may be installed on the right-hand side or left-hand side IMPORTANT: For maximum R.A. flow, flush-mounted acoustic panel must be centered vertically and horizontally over the Return Air opening of the cabinet. Supply air duct collar extensions may be required to prevent short cycling. 1.92 .28 A 50.50” Mounting Holes x 6 52.50” (52-3/4” ROUGH-IN WALL OPENING) 54.75” 54 .75 ” Magnetic Catches x 2 LD19319 Note: 1) See figure on Page 35 for additional R.A. panel and cabinet installation information. 36 JOHNSON CONTROLS FORM 145.18-EG1 (317) LEFT HAND OPENING SHOWN 1.50 1.25 Thermostat mounting location, Cut-out for routing ADA thermostat harness 1/2" Insulation Magnetic Catches x 2 Notes: - Powder coated in 'Appliance White' - Inside panel lined with 1/2" acoustical insulation - Hinged panel complete with magnetic latches - Panel comes either Left or Right hand opening LD19320 JOHNSON CONTROLS 37 FORM 145.18-EG1 (317) Dimensional Data (Cont'd) RETURN AIR PANEL UNIT SIZE A (PANEL WIDTH) B (SLEEVE WIDTH) C (R/A PANEL OPENING) D (ROUGH IN WIDTH) E (UNIT WIDTH) F (UNIT DEPTH) G (NO OA OPTION) G (OA OPTION) 09 / 12 22 3/4 16 16 1/4 20 3/4 ± 1/8 17 17 20 1/4 MIN. 20 1/2 MAX 24 1/4 MIN. 24 1/2 MAX 15 /18 / 24 25 3/4 19 19 1/4 23 3/4 ± 1/8 20 20 23 1/4 MIN 23 1/2 MAX 27 1/4 MIN 27 1/2 MAX 30 / 36 29 3/4 23 23 1/4 27 3/4 ± 1/8 24 24 27 1/4 MIN 27 1/2 MAX 31 1/4 MIN 31 1/2 MAX All dimensions are in inches. 38 JOHNSON CONTROLS FORM 145.18-EG1 (317) SUPPLY GRILLES VERTICAL STACK CABINET WALL STUD TOP VIEW DETAIL A 1/2” DRYWALL 1/8” THICK FIELD SUPPLIED GASKET TAPE APPLIED AROUND FULL PERIMETER OF SUPPLY GRILLE WITH VOLUME DAMPER MOUNTING SCREWS FACTORY SUPPLIED 1” DUCT FLANGE VERTICAL STACK CABINET TOP VIEW OPTIONAL FRAMING STUDS FOR SUPPLY OPENING 2-1/4” MIN. (UNIT SUPPLY DUCT FLANGE TO 1/2” DRYWALL FACE) UNIT SIZE A (SUPPLY GRILLE NOMINAL WIDTH) B (GRILLE WIDTH) C (GRILLE FLANGE WIDTH) D (ROUGH IN WIDTH) E (UNIT WIDTH) 09 / 12 X B=X-0.5" C=X+1.75" 20 3/4 ± 1/8 17 15 /18 / 24 X B=X-0.5" C=X+1.75" 23 3/4 ± 1/8 20 30 / 36 X B=X-0.5" C=X+1.75" 27 3/4 ± 1/8 24 All dimensions are in inches and typical for JCI-supplied grilles only. Check dimensions for field-supplied grilles, as dimensions can be different. JOHNSON CONTROLS DETAIL A LD19321 39 FORM 145.18-EG1 (317) Dimensional Data (Cont'd) Table 35 - UNIT SUPPLY OPENING SIZES HORIZONTAL OPENINGS SINGLE HORIZONTAL MODEL NO TOP OPENING W/ TOP OPENING 9 14W x 12H 12 14W x 14H 15 18 24 Not Available 30 Not Available 36 Not Available TOP OPENING DOUBLE HORIZONTAL TRIPLE HORIZONTAL NO TOP OPENING W/ TOP OPENING NO TOP OPENING 14W x 6H 14W x 8H Not Available Not Available 12 x 8 14W x 6H 14W x 10H Not Available Not Available 12 x 8 16W x 14H 14W x 6H 14W x 10H Not Available 14W x 8H 14 x 12 Not Available 14W x 6H 14W x 12H 14W x 6H 14W x 10H 14 x 12 14W x 10H 16W x 14H 14W x 6H 14W x 10H 14 x 12 14W x 6H 20W x 14H 14W x 6H 16W x 12H 18 x 16 14W x 10H Not Available 14W x 6H 16W x 14H 18 x 16 1. Unit mounted supply grilles will be supplied as double-deflection type. 2. Grilles for unequal airflow applications (e.g., unit-mounted plus ducted supply) shall be provided with integral opposed-blade dampers. 3. All grilles will be supplied in standard "Appliance White" painted finish. 4. Grilles are shipped loose for field installation upon completion of cabinet / ductwork / drywall installation. 5. Top opening size does not change. When combined with any other discharge arrangement, shall be included in determining horizontal opening grille size. 6. Openings marked "Not Available" result in face velocities outside the recommended 300-500 FPM range. 7. Hi-Static Blower option is not recommended or single horizontal discharge openings with unit mounted supply grille. Table 36 - UNIT SUPPLY FACE VELOCITY (FPM) HORIZONTAL OPENINGS MODEL SINGLE HORIZONTAL DOUBLE HORIZONTAL TRIPLE HORIZONTAL TOP OPENING NO TOP OPENING W/ TOP OPENING NO TOP OPENING W/ TOP OPENING NO TOP OPENING 9 291 272 219 Not Available Not Available 510 12 316 344 221 Not Available Not Available 645 15 354 314 283 Not Available 236 471 18 Not Available 391 294 294 235 587 24 Not Available 397 273 364 291 729 30 Not Available 416 276 339 269 538 36 Not Available 410 Not Available 385 261 610 1. Tabulated Face velocities do not account for supply grille free area factor. Face velocities at supply grille will be higher depending on grille type. 2.Face velocities are based on the nominal rated CFM and in feet per minute (FPM). 3. Face velocities are calculated by taking the averate across all openings. Tabulated top opening face velocity is only for units with single Top Opening and no horizontal openings. 40 JOHNSON CONTROLS FORM 145.18-EG1 (317) Hose Kits - NPSH Water Connection LD18126 LD18127 JOHNSON CONTROLS 41 FORM 145.18-EG1 (317) Hose Kits - JIC Water Connection LD19518 LD19519 42 JOHNSON CONTROLS FORM 145.18-EG1 (317) Discharge Configurations RIGHT HAND RISER R FRONT S R LEFT D RA RA S FRONT + LEFT S RA S FRONT + BACK RA R S D RA TOP + FRONT + BACK RA S S D TOP ONLY D S R 3-WAY D TOP + BACK + LEFT S RA RA R R R D RA D D LEFT + BACK S RA RA S FIELD CUT R TOP + BACK R D TOP + FRONT + LEFT RA D R S R D R TOP + LEFT D RA BACK D R TOP + FRONT S R S D RA R S D RA NOTES: 1) RETURN AIR OPENING SIDE IS DEFINED AS FRONT OF UNIT (CHASSIS AND CONTROL SERVICE ACCESS). 2) 3-WAY DISCHARGE ARRANGEMENT IS NOT RECOMMENDED FOR UNIT SIZES 009, 012 3) SINGLE DISCHARGE OPENING (EXCEPT TOP DISCHARGE) IS NOT RECOMMENDED FOR UNIT SIZES 030, 036 JOHNSON CONTROLS 43 FORM 145.18-EG1 (317) Discharge Configurations (Cont'd) LEFT HAND RISER R S R FRONT S D S FRONT + RIGHT S D S D S FRONT + BACK R S D RA D S RA RA R BACK + RIGHT D TOP + FRONT + BACK TOP ONLY S RA RA TOP + FRONT + RIGHT RA R TOP + BACK R D RA D D R FIELD CUT S RA RA R BACK R TOP + RIGHT D RA R D R TOP + FRONT D R S RA R S RIGHT D RA S R S 3-WAY D RA R S D RA TOP + BACK + RIGHT RA NOTES: 1) RETURN AIR OPENING SIDE IS DEFINED AS FRONT OF UNIT (CHASSIS AND CONTROL SERVICE ACCESS). 2) 3-WAY DISCHARGE ARRANGEMENT IS NOT RECOMMENDED FOR UNIT SIZES 009, 012 3) SINGLE DISCHARGE OPENING (EXCEPT TOP DISCHARGE) IS NOT RECOMMENDED FOR UNIT SIZES 030, 036 44 JOHNSON CONTROLS FORM 145.18-EG1 (317) REAR RISER JOHNSON CONTROLS 45 FORM 145.18-EG1 (317) Wiring Diagram 46 JOHNSON CONTROLS FORM 145.18-EG1 (317) JOHNSON CONTROLS 47 FORM 145.18-EG1 (317) THIS PAGE INTENTIONALLY LEFT BLANK. 48 JOHNSON CONTROLS FORM 145.18-EG1 (317) Specifications GENERAL All VSCS-series models ship as a factory-charged package complete with R-410A refrigerant. All units from 3/4 to 3 tons shall be tested and certified by ASHRAE/ANSI/AHRI/ ISO 13256-1 and ETL listed for United States and Canada. ASHRAE/ANSI/AHRI/ISO and ETL labels shall be applied prior to leaving the factory. All units are test operated at the factory. Both cabinets and refrigeration chassis are completely factory wired and prepiped. CABINET The self-supporting cabinet assembly is constructed of heavy gauge, corrosion-resistant, coated steel (minimum 20-gauge thickness for exterior panels). The entire cabinet interior is insulated with 1/2-inch thick, high-density thermal and acoustic insulation. Insulation shall meet NFPA 90, UL-181, and ASTM-C1071 standards, have a flame spread of less than 25, and a smoke developed classification of less than 50 per ASTM E-84 and UL 723. A removable inner service panel seals the fan and compressor compartment during operation. The cabinet base section contains a heavy gauge galvanized steel drain pan and 14-gauge guide rails for the slide-in heat-pump chassis. The drain pan outlet is readily accessible for cleaning (removal of inner service panel required). The drain pan comes standard with a normally closed condensate overflow switch. The drain pan outlet, incorporating a P-trap, is factory connected to the condensate riser. The removable fan and motor assembly is suspended horizontally from an 18-gauge blower mounting deck, which creates an insulated discharge plenum in the upper section of the cabinet. Supply air openings are factory cut according to customer specifications. A noise attenuating insulated privacy air baffle is provided for horizontal supply air openings. All cabinet openings are provided with standard 1-inch drywall flange around the full opening perimeter. • Optional surface-mount thermostat connection. Allows mounting of the space thermostat directly above the unit's return air panel or mounted remotely (requires optional extended harness). Electrical connection to the unit is by a plug-in Molex pigtail connector. Molex pigtail is field wired to thermostat terminals. • Optional 4-inch round Outside Air Opening through top of unit (left- or right-hand configurations available). Unit comes with 4 1/4-inch return air flange. • Optional 4-inch round Outside Air Opening with motorized damper through top of unit (left- or right-hand configurations available). Unit comes with 4 1/4-inch return air flange. Motorized damper is accessible and easily serviced through RA Panel (no additional service door is required). • Optional Stainless Steel Drain Pan for added corrosion resistance. Entire drain pan is fabricated out of heavy gauge stainless steel. • Optional 80-inch cabinet. Reduced height cabinet for applications where additional ceiling clearance is required. • Optional 2-inch cabinet stand. Stand is factory installed to the base of the cabinet. JOHNSON CONTROLS 49 FORM 145.18-EG1 (317) Specifications (Cont'd) • Optional 4-inch cabinet stand. Stand is factory installed to the base of the cabinet (80-inch cabinet only). • Optional 8-inch cabinet stand. Stand is factory installed to the base of the cabinet (80-inch cabinet only). RISER ASSEMBLY Full-length supply, return, and condensate risers can be either factory-assembled onto the cabinet or shipped loose on separate skids. Maximum factory installed riser length is 120 inches. When the slab-to-slab dimension for a given floor is in excess of 118 inches, separate riser extension pieces can be factory provided to reach the required total riser length (riser extensions are field installed). The top of all risers and riser extensions is internally expanded (3-inch depth) to allow connection of each subsequent riser section without the use of couplings. Type ‘M’ copper for risers is standard. Riser placement may be on any of three sides of the cabinet (right, left, or back). Riser knock-outs are located on all three sides, allowing field conversion of riser placement if necessary. Risers and unit must be installed in such a way to prevent freezing of water. Risers are internally piped into the cabinet assembly, including ball shut-off valves and threaded hose connection stubs. The condensate drain riser is insulated with 3/8-inch wall thickness closed-cell foam insulation. • Optional Type ‘L’ copper risers • Optional protective riser cover to prevent riser damage during shipping, handling, and installation REFRIGERATION CHASSIS Each removable heat-pump chassis assembly includes an air-to-refrigerant coil, a waterto-refrigerant coil, a condensate collection drain pan, and features a high efficiency rotary or scroll compressor. The chassis base is fabricated from heavy gauge galvanized steel (14 Ga). A metal enclosure isolates the compressor from the moving air stream in the lower fan compartment. The compressor enclosure is insulated with 1/2-inch thick, 2-pound density insulation. Insulation shall meet NFPA 90, UL-181, and ASTM-C1071 standards, have a flame spread of less than 25, and a smoke developed classification of less than 50 per ASTM E-84 and UL 723. Electrical connection between the cabinet and the chassis is by locking quick-connect plugs (separate high voltage and low voltage plugs). Water supply and return connection to the chassis is by factory-supplied reinforced high-pressure flexible hoses with quicksealing swivel couplings. The hose assemblies are rated for a minimum 350 psig working pressure. Rotary and scroll compressors are mounted on rubber vibration isolators. Compressor motors are provided with internal overload protection. Each refrigeration circuit is thoroughly evacuated and fully charged with R-410A refrigerant before shipment. An external high-pressure switch and a low-suction temperature switch are included in each compressor control circuit. The sealed refrigeration circuit includes a bi-flow thermal expansion valve, with external equalizer. Service gauge ports are provided for field diagnosis and service. The 4-way reversing valve is a pilot operated, sliding piston type with a replaceable magnetic solenoid coil. Each unit is equipped with a liquid line filter drier. 50 JOHNSON CONTROLS FORM 145.18-EG1 (317) Refrigerant-to-air heat transfer coils are constructed of internally enhanced copper tubes, mechanically bonded to enhanced aluminum plate fins. The coaxial refrigerant-to water heat exchangers feature a convoluted inner tube design for high heat transfer efficiency. Standard models feature a copper inner tube surrounded by a steel outer tube and carry a 400-psig waterside working pressure rating. Units shall be capable of operation with an entering fluid temperature range of 20°F to 110°F. • Optional corrosion resistant air-to-refrigerant coil (E-Coat). Coil shall receive a 1-mil thickness of cathodic epoxy type electro-deposit coating to increase corrosion resistance and prevent microbial contamination. • Optional Cupro-Nickel water coil. Water side coaxial condenser coil shall be constructed of cupro-nickel metal alloy for increased resistance to corrosion and contamination buildup. • Optional automatic water flow regulator, factory installed as an integral part of the refrigeration chassis. The automatic flow control valve shall be selected for the nominal rated flow rate and provides constant flow over a 2-80 psi differential pressure range. • Optional Y-strainer with #20 mesh screen is factory installed. • Optional 2-way water control valve. A factory installed 2-way motorized valve is wired in parallel with the compressor control circuit to shut off water flow to the unit when the compressor is off. This feature can significantly reduce power consumption in variable-speed or staged pumping applications. The valve has standard 25 psi close-off rating (optional 60 psi close-off rated valve is available). The actuator is of a slow-closing design to eliminate hydraulic shock. • Optional 3-way water control valve. A factory installed 3-way motorized valve is wired in parallel with the compressor control circuit, to shut off water flow to the unit when the compressor is off. This feature allows loop water to circulate back to return column riser when unit is not in operation and can significantly reduce power consumption in variable-speed or staged pumping applications. The valve has standard 25 psi close-off rating (optional 60 psi close-off rated valve is available). The actuator is of a slow-closing design to eliminate hydraulic shock. • Optional chassis mounted Circulating Pump for single riser systems. Unit chassis is fitted with a circulating pump in applications where supply and return water is circulated in the building through a single riser. • Optional sound isolated chassis for improved sound performance. Integral to chassis, specially designed chassis rails improve vibrational and sound performance of complete unit (US patent pending). INDOOR FAN Forward curved, double inlet and double width, direct-drive centrifugal blowers are used for air movement. Large diameter blower wheels are employed to provide required airflow performance at minimum noise levels. Standard fan motors are PSC types and feature permanently lubricated bearings and internal thermal overload protection. Optional EC motors feature soft start and stop for added occupant comfort, consume less power compared to standard motors, and maintain good fan performance when subjected to higher external static pressures. The fan motors are attached to the blower housings by means of an integral ‘flex-mount’ system, with additional vibration isolation provided by rubber JOHNSON CONTROLS 51 FORM 145.18-EG1 (317) Specifications (Cont'd) mounting grommets. A manual selector switch is accessible through the hinged return air panel, allowing switching between the two available fan speeds (Hi – Low). • Optional Hi-Static PSC motor and blower assembly for applications with extended ductwork layout. • Optional EC motor (ECM). • Optional Hi-Static ECM and blower assembly for applications with extended ductwork layout. • Optional ECM with Continuous Low Speed fan option. Fan continuously circulates air at low fan speed. • Optional Hi-Static ECM with Continuous Low Speed fan option. Fan continuously circulates air at low fan speed. ELECTRICAL/CONTROLS All units are completely factory wired with all necessary operating controls. A standard factory installed, non-fused, electrical disconnect is provided for service convenience and maintenance. • Optional Non-Fused Disconnect • Optional Disconnect with Fusing added to the internal line voltage switch circuit • 2-Speed Fan Control at Thermostat • 3-Speed Fan Control at Thermostat (with ECMs only) Standard unit control consists of a 24-volt electromechanical relay package. The cabinetmounted electrical box contains a 50VA Class II transformer for field connection. The reversing valve solenoid coil shall be energized in cooling mode only. The control system microprocessor board is specifically designed for water source heat pump operation. The control system interfaces with a conventional type thermostat. • Unit shall incorporate a lockout circuit that provides reset capability at the space thermostat, base unit, or by interrupting service power, should any of the following standard safety devices trip and shut off the compressor. • Loss-of-charge/Low-pressure switch • High-pressure switch • Low water temperature protection • Condensate overflow protection • Random start. • Should the high-pressure or low-pressure safeties open three times within two hours of operation (1 hour for low-pressure safety), then lockout requiring manual reset will occur. • Should the low water temperature or condensate overflow safeties trip three times sequentially, then lockout requiring manual reset will occur. • The low-pressure switch shall not be monitored during the initial 30 seconds of a cooling system's operation to prevent nuisance trips. 52 JOHNSON CONTROLS FORM 145.18-EG1 (317) • Unit shall have capability to defeat time delays for servicing. • Unit control board shall have on-board diagnostics and an LED fault code display. • Standard controls shall include anti-short cycle and low voltage protection. • Control board shall monitor each refrigerant safety switch independently. • Control board energizes reversing valve solenoid in cooling only. • Control board shall have random start feature. • Control board shall retain last five fault codes in non-volatile memory, which will not be lost in the event of a power loss. In addition to the external pressure switches, the compressor also has inherent (internal) protection. If there is an abnormal temperature or power rise in a compressor, the internal protection will immediately shut down the compressor. The microprocessor control incorporates features to minimize compressor wear and damage. An anti-short cycle delay (ASCD) is utilized to prevent short cycling of the compressor. Additionally, a minimum run time is imposed any time a compressor is energized. The ASCD is initiated on unit start-up and on any compressor reset or lockout. FILTERS All units are supplied with a 1-inch thick throwaway filter. Filters are accessible through the hinged return air panel without removing the inner service panel. • Optional MERV 8 Filters FIELD INSTALLED ACCESSORIES Acoustic Return Air Panel The flush-mounted return air panel is designed to minimize line-of-sight noise transmission. The panel assembly is fabricated from heavy gauge steel. An insulated, hinged center section allows convenient user access to the unit control panel and filter. The perimeter frame of the panel is mounted to the drywall/framing opening at the front of the cabinet. The heat-pump chassis is fully accessible and removable through the hinged door section. The panel is supplied in standard Appliance White painted finish. Supply Air Grilles Optional supply air grilles shall be supplied for each free discharge outlet directly from the cabinet (non-ducted outlets). All unit mounted supply grilles will be supplied as double deflection type. Grilles for unequal airflow applications shall be provided with integral opposed blade dampers (volume dampers). Grilles will be supplied in standard Appliance White painted finish. Hoses High-pressure flexible hoses with quick-sealing swivel couplings provide supply and return water connections to the chassis. Hose material is fire-rated (UL-94 VO) thermoplastic inner tube, reinforced by a stainless steel wire outer braid. The hose assemblies are rated for a minimum 350 psig working pressure. JOHNSON CONTROLS 53 FORM 145.18-EG1 (317) Specifications (Cont'd) Thermostats • TEC3000 Series Thermostat Included features for the TEC3000 series thermostats are: • Field-selectable BACnet MS/TP (TEC36xx-00-000 Models) or N2 networked communication • USB port configuration • Backlit Liquid Crystal Display (LCD) • Configurable touch screen UI • Mobile Access Portal (MAP) gateway compatibility (MAP Release 4.0 or Later) • Stand-alone and BACnet MS/TP or N2 networked models • Onboard occupancy sensor (TEC3xx1-00-000 and TEC3xx3-00-000 Models) • Single- or two-stage control • Full line of remote TE-6300 series temperature sensors • T701 Series Thermostat Included features for the T701 series thermostats are: • Includes Model T701DFN-1 (Non-Programmable) and Model T701DFP-1 (7-Day Programmable) • Auto-staging fan speed control • Three speed fan control • Remote sensor ready • Dry contact equipped • Backlit display • Electric heat ready • Non-Volatile Memory: all setpoints and programming are permanently stored during power loss • Dual setpoint with adjustable deadband • Keypad lockout • Configurable display • Display either °F or °C • Wall plate available • Self-prompting 54 JOHNSON CONTROLS FORM 145.18-EG1 (317) • T8000 Series Thermostat Included features for the T8000 series Color Touchscreen thermostats are: • Remote control via Wi-Fi with Optional Skyport Cloud Services Wi-Fi Key (ordered separately) • Switchable programmable or non-programmable • Programmable occupancy schedule: reduces operating expenses by controlling the room based on occupant schedules • Up to four heat and two cool stages • Independently adjustable timers and deadbands for all stages of heating and cooling • Passcode security for screen lock and setpoint limits • Programmable fan • Outdoor sensor ready • Multi-lingual display options: provide a user interface in English, French, and Spanish • Weather forecast display capable • Home/away feature • Local equipment runtime trending: provides easy access to energy usage information; shows how much energy was used to heat and/or cool over a 7-day period • SD memory card input: reduces configuration time by making inputting and exporting data between digital room thermostats quick and easy • Configurable alerts: send messages to the digital room thermostat when certain conditions occur, such as when the room temperature exceeds a user-specified value JOHNSON CONTROLS 55 Printed on recycled paper Form 145.18-EG1 (317) Supercedes: 145.18-EG1 (516) © 2017 Johnson Controls P.O. Box 423, Milwaukee, WI 53201 Printed in USA www.johnsoncontrols.com Issued on 3/13/2017
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project