Aspen SPNTWB Installation And Startup Manual

Add to my manuals
24 Pages

advertisement

Aspen SPNTWB Installation And Startup Manual | Manualzz

SPNTWB

Trio Conference Interface

Wideband Bridging

INSTALLATION and STARTUP GUIDE

Fill in for your records:

Serial Number:

Purchase Date:

Software and Hardware Installation and Setup

IMPORTANT

See page 14 for

Minimum Setup Requirements

Visit the ASPEN Support web site:

www.lectrosonics.com/aspensupport/

Also link from the home page: www.lectrosonics.com

Rio Rancho, NM, USA www.lectrosonics.com

SPNTWB

2

LECTROSONICS, INC.

Installation and Startup Guide

Important Safety Instructions

This symbol, wherever it appears, alerts you to the presence of uninsulated dangerous voltage inside the enclosure -- voltage that may be sufficient to constitute a risk of shock.

This symbol, wherever it appears, alerts you to important operating and maintenance instructions in the accompanying literature. Please read the manual.

14) Refer all servicing to qualified service personnel.

Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

15)

WARNING -- TO REDUCE THE RISK OF FIRE OR

ELECTRIC SHOCK, DO NOT EXPOSE THIS AP-

PARATUS TO RAIN OR MOISTURE.

When using your telephone equipment, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following:

1) Read these instructions.

2) Keep these instructions.

3) Heed all warnings.

16) The AC mains plug, or appliance coupler shall be readily available to the operator as a means of power disconnection, if applicable.

17) Unit shall be connected to a MAINS socket outlet with a protective earthing connection.

18) Do not use this product near water for example, near a bathtub, washbowl, kitchen sink or laundry tub, in a wet basement or near a swimming pool.

4) Follow all instructions.

5) Do not use this apparatus near water.

6) Clean only with a dry cloth.

19) Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk of electric shock from lightning.

20) Do not use the telephone to report a gas leak in the vicinity of the leak.

7) Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.

8) Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus

(including amplifiers) that produce heat.

9) Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and third grounding prong. The wider blade or the third prong are provided for your safety.

If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.

21) Use only the power cord and batteries indicated in this manual. Do not dispose of batteries in a fire.

They may explode. Check with local codes for possible special disposal instructions.

22) “CAUTION: To reduce the risk of fire, use only No.

26 AWG or larger (e.g., 24 AWG) UL Listed or CSA

Certified Telecommunication Line Cord”

SAVE THESE INSTRUCTIONS

10) Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.

11) Only use attachments/accessories specified by the manufacturer.

12) Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.

13) Unplug this apparatus during lightning storms or when unused for long periods of time.

Inspection of the Unit

Compare the packing list enclosed with the unit with the original order. Inspect all items for damage. Immediately call 1-800-821-1121 to report any items that are missing or damaged. The sooner you notify us, the sooner you will get any needed replacement items shipped to your location.

Rio Rancho, NM

3

4

SPNTWB

Introduction

The SPNTWB combines the circuit board assemblies from the SPN812 and SPNCWB in a 2RU chassis to provide a complete, stand-alone component for telepresence and audio conferencing systems. The unit can also be used with additional ASPEN processors to add additional inputs and outputs. Setup and adjustments can be made using the control panel software or the front panel LCD interface. Inputs and outputs appearing on the LCD have been consolidated into logical groups to simplify navigation.

The far end audio signals in a conference participate in the automatic mixing algorithm in same manner as local microphones connected to the processor. Three sites connected via two codecs and a telephone line can be bridged into a single conference with the local site.

The ASPEN acoustic echo canceller was developed to address the need for a single acoustic echo canceller that could handle the challenges of multi-site bridging and an unlimited number of microphones. The AEC converges very quickly, then continues to increase the cancellation depth at every opportunity as a conference continues. Cancellation depth will increase even with brief signal peaks from the far end, and convergence will never be lost with any type of signal or in double talk situations.

Signals from the far ends of the conference are routed to the local sound system as well as serving as the reference signal for the AEC. Audio from the local microphones (which includes far end audio from the local loudspeakers) is routed to the AEC via a second final mix. Far end audio present in the microphone signal mix is cancelled, and the output of the AEC is routed back to the far ends through the matrix.

The AEC in combination with the patented gain proportional mixing algorithm* provides outstanding audio quality without echo heard at the far ends.

An ethernet port is provided for setup and control via standard network connections, and an RS-232 port is provided for use with remote control systems. The design allows simultaneous, multi-point third party control.

A two channel power amplifier is included for loudspeakers in the local sound system. The power amplifier is driven by final mix outputs from the matrix and has a full set of signal processing, including parametric EQ, compressor and limiter. Class-D amplification is implemented with a late generation component that provides exceptional efficiency, low heat and excellent audio performance. The amplifier cannot be damaged by wiring errors.

LECTROSONICS, INC.

Rio Rancho, NM

Installation and Startup Guide

Table of Contents

IMPORTANT ............................................................................1

Important Safety Instructions...............................................3

Inspection of the Unit ............................................................3

Introduction ............................................................................4

Front Panel .............................................................................6

Rear Panel ..............................................................................7

Hardware Installation ............................................................8

Installing the chassis into a rack ..........................................8

Cables .................................................................................8

Audio Connectors ...............................................................8

Audio Inputs – Unbalanced ..................................................8

Audio Outputs ......................................................................9

Programmable Inputs ...........................................................9

Programmable Outputs ........................................................9

Power Amp Outputs .............................................................9

ASPEN RS-232 Port Wiring Diagram ................................10

Crestron

®

and AMX

®

Port Wiring Diagram .........................10

Cabling Of Stacked Units ...................................................10

Software Installation ...........................................................11

Refer to the Help Files .........................................................11

Creating an ASPEN Installer Disk ......................................11

Software and Firmware Updates ........................................12

Firmware Update Procedure ...............................................12

Update Procedure ..............................................................12

MCU Recovery from Interrupted Firmware Update ...........13

Stacking Multiple Units .......................................................14

Using the Control Panel ......................................................14

Minimum Setup ....................................................................14

The Signal Flow Screen ......................................................16

Using the LCD ......................................................................18

LCD Categories and Settings .............................................20

Network Setup .....................................................................21

Web Browser Interface ........................................................21

Service and Repair ..............................................................22

Returning Units for Repair .................................................22

FCC PART 68 COMPLIANCE INFORMATION .....................23

INDUSTRY CANADA NOTICE .............................................23

5

SPNTWB

Front Panel

The SPNTWB includes a front panel LCD and rotary style navigation control for adjustment without the need for a computer interface. The headphone output is used to monitor each final mix for diagnostics and system checkout.

LCD

Navigation/Select

Control

Blue LEDs on the right side of the front panel indicate power status and communications through USB, serial and ethernet ports. The center white LED blinks to indicate an error, and glows during firmware updates.

USB Port POWER Switch

Headphone Monitor MCU Recovery recessed pushbutton

Headphone Monitor

Used to monitor individual final mix buses as selected on the LCD. Standard 1/4 inch jack and level control.

Drives both channels of stereo headphones.

MCU Recovery (recessed pushbutton)

Used in the procedure to recover from an interrupted firmware update procedure. See section on

Firmware

Update Procedure for details on usage.

LCD

Allows setup and adjustment of most operating parameters and for minor adjustments without a computer interface.

Navigation/Select Control

Used to navigate menus and make value selections and settings on the LCD.

Firmware Update recessed pushbutton

Comm

LED

Alert

LED

Power LED

USB Port

Standard USB connector for the setup and control of an SPNTWB from a Windows

®

XP, Vista or 7 computer system* with USB interface.

Firmware Update (recessed pushbutton)

Used in the procedure to update the firmware in the processor. See the section on

Firmware Update Pro-

cedure for details.

Status LEDs

• Comm LED - blinks to indicate USB, RS-232 and ethernet communication

• Alert LED - blinks to indicate fault or error

• Alert LED - glows white during firmware updates

• Power LED - glows to indicate power ON

6

*Windows is a registered trademark of Microsoft Corp.

LECTROSONICS, INC.

Rear Panel

Cooling Fan

Outlet

Programmable Input and Output Ports

Balanced Outputs

Installation and Startup Guide

Balanced Inputs

Made In the USA

Power Inlet RS232

Serial Port

Ethernet

Port

Data/Audio

Bus Ports

Remote

Control

Power Amp

Outputs

Line Outputs

(Codecs)

Line Inputs

(Codecs)

Telephone

Set/Line

Power Inlet

The switching power supply will operate with line voltages between 100 and 240 VAC. The inlet socket is a standard 3-pin C14 type that accepts any cordset with a

C13 connector.

Cooling Fan

The microprocessor monitors the internal temperature of the processor and controls the variable speed fan as needed. Operating temperature is very well regulated.

RS-232 and Ethernet Ports

Each host assembly provides RS-232 and Ethernet ports for communication with the microprocessor. The ports can be utilized simultaneously for monitoring, setup and control.

ASPEN Ports

This gigabit bus transports audio and data from one board to the next through CAT-6 cabling and RJ-45 connectors. Processors are normally installed with the Master unit on top and Slave units below it. The cabling is then connected from the uppermost jack on one board to the lowermost jack on the unit just above it. See page

9 for more information.

Balanced Mic/Line Inputs

Every mic/line input is a balanced, differential type with adjustable gain from -10 to +60 dB. Connectors are a standard 5-pin Phoenix depluggable type with adjacent channels sharing a common ground.

Balanced Outputs

All outputs are a balanced, differential type. Channels 1 through 8 on each board are nominal line level outputs with gain adjustment from -60 to +20 dB. Channels 9 through 12 on each board are also line level outputs with switchable attenuation of -20 and -40 dBu nominal levels (mic level), with gain adjustment from OFF to +20 dB.

Programmable Input and Output Ports

Programmable inputs and outputs used to control levels, settings, indicate the current state of a programmable input and control a variety of other parameters.

ASPEN Bus Data/Audio Ports

These RJ-45 jacks carry the audio signals and control data between each system board as well as units stacked together.

Remote Control

These RJ-45 jacks provide interfaces for RCWTH4 remote control units. Each jack is assignable to CODEC

1 or 2, or to the telephone line.

Conferencing Inputs and Outputs (Codecs)

Analog audio input and output connectors for the Codec ports.

Telephone Set/Line

RJ11 jacks for connecting a standard telephone line and a single-line telephone set.

Power Amp Outputs

The amplifier is designed to run continuously (idle or with a load) without heat buildup, making it ideal for permanent installations where prolonged operation is required.

Rio Rancho, NM

7

8

SPNTWB

Hardware Installation

Installing the chassis into a rack

Install the chassis so that the cooling fan vent is not blocked. Mount with 4 rack screws using the appropriate mounting holes. Use nylon washers to prevent damage to the front panel’s finish when tightening the mounting screws.

All ASPEN processors have internal switching power supplies that can tolerate voltages ranging from 100 to 240 VAC. Use an approved power cord with an IEC

60320 C13 connector.

Cables

It is recommended to use lacing bars for cable strain relief when mounting in a rack. Use only professional audio cable with proper shielding – typically, two conductor plus ground/shield.

Audio Connectors

The analog audio inputs and outputs are connected through 5 pin de-pluggable connectors. Strip the insulation back 1/8 to 3/16” but do not tin (apply solder to) the leads. Insert the wire into a de-pluggable connector, leaving less than 1 mm of bare wire exposed, then tighten the retaining screw.

Caution: Do not overtighten the screws.

Retaining Screw

(Do not overtighten)

5-pin depluggable connector

Audio Inputs – Unbalanced

Unbalanced audio sources include items such as consumer VCR’s, DVD players, etc., which can be connected with either two wire or three wire cables. The (+) terminal of the source is connected to the (+) terminal of the processor. The shield and (–) connections are made as shown here.

Three wire cables should have the shield connected to the (–) connector at the source end of the cable.

Shield

Unbalanced source to

ASPEN input – 3-wire cable

Two wire cables should have a jumper between the processor (–) input and ground.

Shield

Unbalanced source to

ASPEN input – 2-wire cable

Do not leave more than

1 mm of exposed wire beyond the connector.

Do not apply solder to leads

Note the labeling on the rear panel for the positive and negative leads. Ground is shared between two connections (the center pin).

Note: ASPEN processors do not have a “pin 1 problem.” Inputs and outputs are true differential connections.

Audio Inputs – Balanced

Balanced audio sources connect to the processor inputs in a straight “pin to pin” configuration.

Shield

Balanced source to

ASPEN input

LECTROSONICS, INC.

Audio Outputs

The line outputs are a balanced differential configuration which can drive balanced or unbalanced inputs on other audio equipment with the wiring shown here.

Balanced output to a balanced input is a straightforward

“pin to pin” configuration.

Shield

Balanced output to balanced destination

Balanced output to unbalanced input with a 3-wire cable is connected with the cable shield added to the

(–) terminal on the destination input.

Shield

Balanced output to unbalanced destination – 3-wire cable

Balanced output to unbalanced input with a 2-wire cable is connected with the output (–) connected to the cable shield at the processor output.

Installation and Startup Guide

Programmable Inputs

Programmable inputs are provided to enable external control over a variety of parameters. Each input can respond to a contact closure, a DC voltage source, or the variable voltage output from a potentiometer. The following illustrates common connections to the programmable input pins.

Potentiometer Connection for

Analog Control of Gain

10K Linear Potentiometer

CCW

CW

+5V

To Programmable Input Pin

Gnd

Contact Closure as Programmable Input

To Programmable Input Pin

Gnd

DC Voltage Source as Programmable Input

To Programmable Input Pin

0VDC (Off) to +5VDC (On)

Gnd

Programmable

Inputs

Programmable

Outputs

Ground

+5VDC

Shield

Balanced output to unbalanced destination – 2-wire cable

Power Amp Outputs

Each output can drive a variety of loads, including loudspeakers, long cable runs and headphones.

The BTL (bridge tied load) configuration allows the two channels to be wired in parallel on a common load to double the output power.

+

-

+

-

Programmable Outputs

Programmable outputs are used for several purposes:

• indicate the current state of a programmable input

• monitor activity on telephone or codec interfaces

• monitor active preset changes

Each programmable output is the electrical equivalent of a contact closure to ground. When a programmable output is “active,” it conducts current to ground. When the programmable output is “inactive,” no current flows to ground. The maximum usable voltage for the programmable outputs is 40 V and they will safely conduct up to 100 mA DC continuous.

Both LEDs and 5V relay coils can be powered by the

+5 V DC pins on the programmable input connector, as long as the maximum combined current for all LEDS and relay coils does not exceed 100 mA.

Rio Rancho, NM

9

SPNTWB

LED is ON when the programmable output is active

+5VDC

380 Ohms

Pro gr amma b le Output Pi n

LED is OFF when the programmable output is active

+5VDC

380 Ohms

Programmable Output Pin

GND

Relay is on when the programmable output is active

Rel a y Coi l

Coil current <100mA

1N4001 or equi v .

Exte r na l

DC V oltag e

Source

(<40VDC)

Pro gr amma b le Output Pi n

GND

Note: The diagram above shows an external DC source powering the relay coil. This is necessary whenever coil voltages exceed 5 volts.

LOGIC INPUTS

LOGIC OUTPUTS

GROUND

5VDC

Cathode

Anode

R

V

LOGIC IN 3

ON

IN 3

OFF

CCW

IN 1

380 TO

500 OHM

ANODE

LED

CATHODE

CW

10K

LINEAR

POT

LOGIC

OUT 7

Anode Cathode

Crestron

®

and AMX

®

Port Wiring Diagram

ASPEN

RS-232

Port

Female jack

TX

RX

GND

7

8

9

3

4

5

6

1

2

Wiring Diagram

7

8

9

3

4

5

6

1

2 RX

TX

GND

Crestron

RS-232

Port

Male jack

Male connector

Female connector

Cabling Of Stacked Units

In a stacked configuration, ASPEN processors must be interconnected as shown here. Each Slave unit in a stack gathers data and audio signals from the unit below it, adds its own signals and passes the total on to the unit above it. At the top of the stack, the Master unit gathers all signals from below, adds its own and then sends the total back down the bus to all Slave units below it. In this manner, all Slave units have access to all inputs on any unit in the stack.

Each circuit board has an upper and a lower CAT-5 connector. Since there are two circuit boards in a 2RU unit, the circuit boards are connected in the same manner as if they were in separate chassis. The ASPEN bus is bidirectional, handling data and audio signal forward and back propagation through a single cable connection.

1RU SPN

Processor configured as

Master

ASPEN PORT

ASPEN RS-232 Port Wiring Diagram

Wiring Diagram

ASPEN Device to PC

ASPEN

RS-232

Port

TX

RX

GND

6

7

4

5

8

9

1

2

3

DCE pin functions

7

8

9

5

6

3

4

1

2

DCD

RX

TX

DTR

GND

DSR

RTS

CTS

RI

Host

Serial

Port

(PC)

DTE pin functions

Female jack

Male jack

Male connector

Female connector

2RU SPN

Processor configured as intermediate

Slave

1RU SPN

Processor configured as lowermost

Slave

The processors automatically configure themselves for

Master and Slave status as determined by the cabling.

If a unit is connected to another unit above it through the upper connector, it is automatically configured as a Slave. If there is no unit above it, then it becomes a

Master.

10

LECTROSONICS, INC.

Installation and Startup Guide

Software Installation

NOTE: Uninstall any previous version before installing the software.

ASPEN Control Panel software can be installed from the disk supplied with each processor, or from files downloaded from the ASPEN Support web site.

http://www.lectrosonics.com/aspensupport

Installation is straightforward and requires no special instructions.

The downloaded ASPEN Control Panel Installer will automatically install the USB driver, GUI and Help files.

The disk supplied with the processor has separate installers. Make sure you have at least the USB driver and control panel GUI installed.

The Welcome screen appears first with a brief message about closing other programs before installing. Click

Next to continue.

The third screen displays an option to select the desired installation. It is best to check all three boxes so the the USB driver, Control Panel and Help utility will all be installed.

The next screen displays the License Agreement.

Click on I Agree to continue.

Follow the on-screen prompts to complete the installation. On the last screen, click

Finish to exit the installer.

Refer to the Help Files

Once the processors are installed, configured and communicating with a computer system, refer to the Help files in the software ASPEN Control Panel program for additional information regarding the available settings, adjustments and control.

Creating an ASPEN

Installer Disk

If you do not have the disk supplied with the processor, go to the web site and download the ASPEN Installation

Disk .iso file.

http://www.lectrosonics.com/aspensupport/index.php/ installation-disk

Save the file to your local drive in a familiar location.

Open a disk copier utility such as Roxio Classic and select the operation to Burn from a Disk Image File.

NOTE: The .iso file cannot be simply copied to the disk. The disk recording utility must run a process that creates a disk from a stored image file.

The .iso file format is recognized by almost any disk creation software.

Rio Rancho, NM

11

SPNTWB

Software and Firmware

Updates

On ASPEN models with a front panel LCD, the firmware version is displayed on the Main menu screen.

For all ASPEN models, the firmware version is displayed in the Control Panel program when connected to the processor.

Firmware version

Firmware Update

Procedure

Update Procedure

1) It is assumed that the USB drivers and ASPEN control panel software have been installed. If not, go the the web site and download the Control Panel Installer and follow the instructions to install the USB driver, GUI and

Help file.

http://www.lectrosonics.com/aspensupport/index.php/ control-panel-software

2) Launch the Control Panel program. After the panel opens, click on Connect->Update Firmware... The

Update Wizard will open, with instructions on connecting and configuring the processor.

Firmware version

Obtaining Updates

The latest versions of software and firmware can be downloaded from the ASPEN support site: http://www.lectrosonics.com/aspensupport

ASPEN Control Panel Updates:

Open the Control Panel program and choose

Help-

> Check for Updates... from the Main menu. If and update is available, it will be downloaded and installed automatically.

Firmware Updates:

Downloaded files arrive in a single .zip file with the model number and version indicated by the filename.

Extract the file to a folder on your local drive. The resulting filename will indicate the model number and version, followed by the extension “.update.”

3) On the processor, hold the Firmware Update pushbutton switch in with a pen or paper clip and turn on the power to the processor. The unit will boot into the firmware update mode and the white Alert LED on the processor front panel will glow.

Firmware Update pushbutton

White Alert LED

4) Connect the processor to the computer with the USB cable.

12

LECTROSONICS, INC.

5) Click on Next in the control panel and another page will open, allowing you to select the device to be updated. Highlight the device and click Next to proceed.

6) The next page allows you to select the update file.

Use the “Browse” button to point at the firmware update file and click

Next to continue.

Installation and Startup Guide

8) Do not disturb the USB cable connection during the update process. The firmware update takes up to 15 minutes to complete. Be sure the computer does not go into hibernation or sleep mode during the update process.

NOTE: If the procedure is interrupted, see the next section on recovery

9) When the update is complete, click

Finish to exit the

Update Wizard.

10) Cycle the power on the processor to restart using the updated firmware.

MCU Recovery from Interrupted Firmware

Update Procedure

If instructed to do so by Lectrosonics Customer Support, the firmware in a non-functioning unit can be restored.

Launch the Control Panel program. After the panel opens, click on

Connect->Update Firmware...

In the lower part of the screen is a check box that is used only for the recovery process. When the box is checked, the instructions will change to describe the recovery procedure.

Browse button

Recovery check box

7) Review the information displayed and click on

Start

Update.

Follow the on-screen prompts to return the unit to normal operation.

Rio Rancho, NM

13

SPNTWB

Stacking Multiple Units

If Slave units are not powered up when the Master unit boots up, the Slave may not be detected for several minutes. It is good practice to turn all units on simultaneously or turn on Slave units before turning on the

Master unit.

The available processors will appear in a “stack” in the control panel. The Master unit details will appear at the top, with Slave units below it appearing in the order that they are connected with the cable connections to the

ASPEN port jacks.

The Master unit connected directly

The Master and Slaves connected below it

Click OK to open the control panels

Minimum Setup

A required minimum setup is needed to allow the processor to pass signals and provide acoustic echo cancellation:

• Define the Inputs and adjust gain

• Define the Crosspoints

• Define the mixes to be used as signal sources for the outputs

• Define the Outputs and adjust levels

• Configure the Conferencing Connections

Inputs

Click on the

Inputs tab. The setup screen provides controls for gain, signal polarity (phase) and muting, with level indicators. Connect signal sources and adjust the gain as needed.

Input gain slider

Input signal level

Refer to the cabling diagram for the ASPEN ports in the section entitled Hardware Installation.

Using the Control Panel

To connect to connect a running ASPEN device, choose a connection method from the Connect menu: USB,

Network or Serial. The device can be configured directly when connected.

USB, Network or Serial

Input gain value

Inputs screen

Crosspoints

Click on the

Mix Matrix tab. Inputs are assigned to crosspoints which provide the signal sources for the outputs.

To work on a system design project, choose an option from the Project menu. You may create a new project or open an existing project.

Choose Help->ASPEN Online Help... to open an extensive Help system describing the may features and functions of the Control Panel program.

Mix Matrix screen

14

LECTROSONICS, INC.

Output Sources

Click on the Output Source tab. These assignments pass the matrix mixes to the outputs.

Installation and Startup Guide

Acoustic Echo Canceller

Click on the Acoustic Echo Canceller tab at the bottom of the conferencing screen. The AEC (acoustic echo canceller) can be enabled on any or all of the conference interfaces. Strip chart metering indicates the performance of the AEC on each interface.

Select the desired interface to display, or to display all four simultaneously.

Select display of individual or all interface screens

Pull down menu for mix assignment

Output Source screen

Outputs

Click on the

Outputs tab. This allows adjustment of the gain and muting of each output. Level metering is provided for accurate setup.

Conferencing screen (AEC setup selected)

Outputs screen

Conference Connections

Click on the Conferencing tab. Conferencing settings define the behavior of the Codec and Telephone interfaces.

Select Telephone, CODEC and

AEC setup screens

Conferencing screen (Telephone Interface setup selected)

Rio Rancho, NM

15

SPNTWB

The Signal Flow Screen

Select the Signal Flow tab. This comprehensive, intuitive interface allows settings to be made through the entire signal chain. Double left click and single right click actions open setup and status dialogue boxes.

The view may be panned or zoomed as needed. Hold down the CTRL key and press + to zoom in. Hold down the CTRL key and press - to zoom out. The mouse scroll wheel can also be used. Hold down the

CTRL key and turn the mouse wheel up or down to zoom in or out.

16

LECTROSONICS, INC.

Unused crosspoint columns can be hidden and unhidden by highlighting a range of Mixes across the top, followed by a right click and selection of the desired state.

Installation and Startup Guide

Rio Rancho, NM

17

SPNTWB

Using the LCD

The LCD can be used to check current settings or make adjustments without using a computer interface.

Boot Screen

Shortcut Buttons

LCD Backlight Toggle: Press both the LEFT and

RIGHT buttons to turn the backlight on and off.

Emergency Mute (panic button): Pressing the UP and DOWN buttons together will mute all outputs to remedy situations such as runaway feedback.

Restore Default Settings (Master Reset): Hold in the LEFT and UP buttons while turning on the power to restore the factory default settings. The Alert LED will glow white during the process, which takes about

75 seconds to complete.

Panel Lock/Unlock

From the Main Window, use the rotary control to select

SYS in the lower row window and press the center switch. Then scroll down with the rotary control to the menu item named Front Panel Lock and press the center switch to enter the setup screen.

Main Window

The LCD will show the mode, the position and total number of units in the stack.

Shown here is the Master as unit 1 of 2.

Navigation Control

The navigation control for the LCD consists of a rotary control and four directional buttons for selection of menu items and to enter values. The four outer buttons are referenced as LEFT, RIGHT, UP and DOWN. Pressing the center of the rotary control provides a “select” or

“center switch” function.

Center Switch

Select the Unlocked/Locked item with the rotary control, press the center switch.

A prompt will appear asking you to enter the passcode.

Press both Left and Right buttons to turn the LCD backlight OFF and ON

The LEFT functions as a BACK button to return to the previous menu from setup screens as prompted by the

symbol in the lower left corner of the LCD.

18

The factory default passcode is five presses of the center switch. Once the correct passcode is entered, the panel will allow access to the screen items to change the unlocked/locked status, enter a new passcode and save the results.

The passcode can consist of any combination of five successive button presses of the four outer switches and the center switch such as: LEFT > RIGHT > UP >

DOWN > CENTER.

LECTROSONICS, INC.

After selecting the mode and/or changing the passcode, select SAVE with the rotary control and press the center switch to save the settings.

Installation and Startup Guide

Navigating Individual Settings

The following example illustrates the structure of the

LCD screens used to set up the processor.

Select a category from the Main Screen.

A progress bar will appear as the settings are saved.

Press the LEFT (9:00 o’clock) button to return to the previous screen.

Master Reset

Hold the LEFT and UP buttons in at power up to restore factory default settings.

A submenu will provide a list of the specific adjustments that can be made in that category. Rotate the scroll wheel to highlight the desired setting and press the center switch to select it.

WARNING: Master Reset will remove all stored settings, unlock the control panel and reset the passcode to five center button presses.

Master Reset takes about 75 seconds to complete while the Alert LED on the front panel glows white.

The display will then return to the Main Window and the power LED will light up to indicate power ON and a

“ready” status.

EXAMPLE: Mic/Line Input Setup accesses a setup screen where gain values, muting, phantom power, polarity (phase) and delay can be adjusted.

Highlight the desired item and press the center switch to enter the value for this setting. Press the center switch to store the new setting (item highlight is removed) before selecting another item or returning to the previous menu.

NOTE: Press the center switch to store the value

(highlight is removed) before navigating to a different item or menu.

Rio Rancho, NM

19

SPNTWB

LCD Categories and

Settings

INP (Input)

• Input Levels

• Mic/Line Input Setup

• Conference Input Setup

• Test Sig Input Setup

• Compressor Setup

• Noise Reduction Setup

• ADFE Filter Setup

• EQ Filter Setup

• Input Group Setup

MAT (Matrix)

• Crosspoint Gain

• Crosspoint Mute

• Crosspoint Mix Mode

• Crosspoint Invert

OUT (Output)

• Output Levels (a level meter display only)

• Output Setup (enter gain, muting and delay; includes attenuation value display)

• Conference Output Setup

• Output Source

• Compressor Setup

• Limiter Setup

• EQ Filter Setup

• Output Group Setup

RPC (Rear Panel Control)

• Prog Input Setup

• Virt Prog Input Setup (slave unit triggers from Prog

Input activity on Master unit)

• Prog Output Setup

• RP Input Gain Setup

• RP Output Gain Setup

• RP Crosspoint Gain

• Input Ch Activity

PRE (Presets)

• Recall Settings

• Store Settings

• Reset to Defaults

• Run on Recall Macro

• Powerup Defaults

• Protected Settings

SYS (System)

• Conferencing Setup

Telephone Interface

DTMF and Dialing

Codec 1 Interface

Codec 2 Interface

AEC Configuratrion

AEC Status

Remote Control Ports

• Headphone Monitor

• Command View

• Network Settings

• RS232 Settings

• Set Time

• Set Date

• Timer Setup

• Alarm Setup

• Event Setup

• Test Signal Control

• Run Macro

• Run-On-Powerup Macro

• Front Panel Lock

20

LECTROSONICS, INC.

Network Setup

The SPNTWB is IP addressable over an ordinary Ethernet network. The use of DHCP to configure the network interface is recommended for easy setup.

Using the front panel LCD, navigate to SYS>Network

Settings and set Use DHCP to YES.

Installation and Startup Guide

Web Browser Interface

A simple interface is provided to communicate directly with the processor through a network using the HTTP port and a standard browser. This interface provides access to the processor in the same manner as the

Command Terminal interface in the software.

Launch your browser and enter the IP addresses assigned to the processor in the top window.

When the processor is connected a summary screen will appear to verify the connection. Click on the link to enter the dialogue screen.

Connect the processor into the network and cycle the power. The processor will boot up and the DHCP server will assign an IP address. The address can be viewed in the

Network Settings display.

IP address will appear here.

Click on the link to enter the dialogue screen

Enter ASPEN commands and view the replies to verify the processor setup or to make adjustments.

NOTE: Changes to the network settings do not take effect until the processor power is cycled off and back on again.

Enter Commands here

View Replies here

Rio Rancho, NM

21

SPNTWB

Service and Repair

If your system malfunctions, you should attempt to correct or isolate the trouble before concluding that the equipment needs repair. Make sure you have followed the setup procedure and operating instructions. Check the interconnecting cables and then go through the Troubleshooting section in this manual.

We strongly recommend that you do not try to repair the equipment yourself and do not have the local repair shop attempt anything other than the simplest repair. If the repair is more complicated than a broken wire or loose connection, send the unit to the factory for repair and service. Don’t attempt to adjust any controls inside the units. Once set at the factory, the various controls and trimmers do not drift with age or vibration and never require readjustment.

There are no adjustments inside that will make a malfunctioning unit start working.

LECTROSONICS’ Service Department is equipped and staffed to quickly repair your equipment. In warranty repairs are made at no charge in accordance with the terms of the warranty. Out-of-warranty repairs are charged at a modest flat rate plus parts and shipping. Since it takes almost as much time and effort to determine what is wrong as it does to make the repair, there is a charge for an exact quotation. We will be happy to quote approximate charges by phone for out-of-warranty repairs.

Returning Units for Repair

For timely service, please follow the steps below:

A. DO NOT return equipment to the factory for repair without first contacting us by e-mail or by phone. We need to know the nature of the problem, the model number and the serial number of the equipment. We also need a phone number where you can be reached 8 A.M. to 4 P.M. (U.S. Mountain Standard Time).

B. After receiving your request, we will issue you a return authorization number (R.A.). This number will help speed your repair through our receiving and repair departments. The return authorization number must be clearly shown on the

outside of the shipping container.

C. Pack the equipment carefully and ship to us, shipping costs prepaid. If necessary, we can provide you with the proper packing materials. UPS or FEDEX is usually the best way to ship the units. Heavy units should be “doubleboxed” for safe transport.

D. We also strongly recommend that you insure the equipment, since we cannot be responsible for loss of or damage to equipment that you ship. Of course, we insure the equipment when we ship it back to you.

Lectrosonics USA:

Mailing address:

Lectrosonics, Inc.

PO Box 15900

Rio Rancho, NM 87174

Shipping address:

Lectrosonics, Inc.

581 Laser Rd.

Rio Rancho, NM 87124

E-mail: www.lectrosonics.com [email protected]

Telephone:

(505) 892-4501

(800) 821-1121 Toll-free

(505) 892-6243 Fax

Lectrosonics Canada:

Address:

49 Spadina Avenue,

Suite 303A

(416) 596-2202

(877) 753-2876 Toll-free

Toronto, Ontario M5V 2J1 (877-7LECTRO)

Sales: [email protected]

Service: [email protected]

LECTROSONICS, INC.

22

Installation and Startup Guide

FCC PART 15 COMPLIANCE INFORMATION

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense

FCC PART 68 COMPLIANCE INFORMATION

This equipment complies with Part 68 of the FCC rules. Located on the equipment is a label that contains, among other information, the ACTA registration number and ringer equivalence number (REN.) If requested, this information must be provided to the telephone company.

The REN is used to determine the quantity of devices which may be connected to the telephone line. Excessive

REN’s on the telephone line may result in the devices not ringing in response to an incoming call. In most, but not all areas, the sum of the REN’s should not exceed five (5.0). To be certain of the number of devices that may be connected to the line, as determined by the total REN’s contact the telephone company to determine the maximum REN for the calling area.

This equipment cannot be used on the telephone company-provided coin service. Connection to Party Line Service is subject to State Tariffs.

If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. If advance notice isn’t practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right the file a complaint with the FCC if you believe it is necessary.

The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the operation of the equipment. If this happens, the telephone company will provide advance notice in order for you to make the necessary modifications in order to maintain uninterrupted service.

If trouble is experienced with this equipment, please contact:

Lectrosonics, Inc.

581 Laser Rd. Rio Rancho, NM 87124

Tel: 505-892-4501

Fax: 505-892-6243

If the trouble is causing harm to the telephone network, the telephone company may request you to remove the equipment from the network until the problem is resolved.

This equipment uses the following USOC jacks: RJ11C

It is recommended that the customer install an AC surge arrester in the AC outlet to which this device is connected.

This is to avoid damaging the equipment caused by local lightening strikes and other electrical surges.

INDUSTRY CANADA NOTICE

This product meets the applicable Industry Canada technical specifications/Le présent materiel est conforme aux specifications techniques applicables d’Industrie Canada.

The Ringer Equivalence Number is an indication of the maximum number of devices allowed to be connected to a telephone interface.

The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the RENs of all the devices does not exceed five.

L’indice d’équivalence de la sonnerie (IES) sert à indiquer le nombre maximal de terminaux qui peuvent être raccordés à une interface téléphonique.

La terminaison d’une interface peut consister en une combinaison quelconque de dispositifs, à la seule condition que la somme d’indices d’équivalence de la sonnerie de tous les dispositifs n’excède pas 5.”

Rio Rancho, NM

23

LIMITED THREE YEAR WARRANTY

The equipment is warranted for three years from date of purchase against defects in materials or workmanship provided it was purchased from an authorized dealer. This warranty does not cover equipment which has been abused or damaged by careless handling or shipping. This warranty does not apply to used or demonstrator equipment.

Should any defect develop, Lectrosonics, Inc. will, at our option, repair or replace any defective parts without charge for either parts or labor. If Lectrosonics, Inc. cannot correct the defect in your equipment, it will be replaced at no charge with a similar new item. Lectrosonics, Inc. will pay for the cost of returning your equipment to you.

This warranty applies only to items returned to Lectrosonics, Inc. or an authorized dealer, shipping costs prepaid, within three years from the date of purchase.

This Limited Warranty is governed by the laws of the State of New Mexico. It states the entire liablility of Lectrosonics Inc. and the entire remedy of the purchaser for any breach of warranty as outlined above. NEITHER LECTROSONICS, INC. NOR

ANYONE INVOLVED IN THE PRODUCTION OR DELIVERY OF THE EQUIPMENT

SHALL BE LIABLE FOR ANY INDIRECT, SPECIAL, PUNITIVE, CONSEQUENTIAL,

OR INCIDENTAL DAMAGES ARISING OUT OF THE USE OR INABILITY TO USE

THIS EQUIPMENT EVEN IF LECTROSONICS, INC. HAS BEEN ADVISED OF THE

POSSIBILITY OF SUCH DAMAGES. IN NO EVENT SHALL THE LIABILITY OF

LECTROSONICS, INC. EXCEED THE PURCHASE PRICE OF ANY DEFECTIVE

EQUIPMENT.

This warranty gives you specific legal rights. You may have additional legal rights which vary from state to state.

581 Laser Road NE • Rio Rancho, NM 87124 USA • www.lectrosonics.com

(505) 892-4501 • (800) 821-1121 • fax (505) 892-6243 • [email protected]

5 November 2013

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project