CM-18Ⅱ CM-36Ⅱ

CM-18Ⅱ CM-36Ⅱ
Professional Moving Wash
CM-18Ⅱ
CM-36Ⅱ
User Guide
Professional Entertainment Technology
Innovation, Quality, Performance
21A
TABLE OF CONTENTS
EC Declaration of Conformity
We declare that our products (lighting equipments) comply with the
1. Safety Instruction
following specification and bears CE mark in accordance with the
provision of the Electromagnetic Compatibility (EMC) Directive
89/336/EEC.
2. Technical Specification
EN55014-2: 1997 A1: 2001, EN61000-4-2: 1995; EN61000-4-3: 2002;
EN61000-4-4: 1995; EN61000-4-5: 1995, EN61000-4-6: 1996,
3. How To Set The Unit
EN61000-4-11: 1994.
&
Harmonized Standard
4. How To Control The Unit
EN60598-1: 2000+ALL: 2000+A12: 2002
Safety of household and similar electrical appliances
5. Troubleshooting
Part 1: General requirements
6. Fixture Cleaning
20A
1A
1.Safety Instruction
6. Fixture Cleaning
The cleaning of internal and external optical lenses and/or mirrors must be carried out
periodically to optimize light output. Cleaning frequency depends on the environment in
WARNING
Please read carefully the instruction, which includes important information
which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater
about the installation, usage and maintenance.
accumulation of dirt on the unit’s optics.
y Clean with soft cloth using normal glass cleaning fluid.
y Please keep this User Guide for future consultation. If you sell the unit to another user, be
sure that they also receive this instruction booklet.
y Unpack and check carefully there is no transportation damage before using the unit.
y Always dry the parts carefully.
y Clean the external optics at least every 20 days. Clean the internal optics at least every
30/60 days.
y Before operating, ensure that the voltage and frequency of power supply match the power
requirements of the unit.
y It’s important to ground the yellow/green conductor to earth in order to avoid electric
shock.
y The unit is for indoor use only. Use only in a dry location.
y The unit must be installed in a location with adequate ventilation, at least 50cm from
adjacent surfaces. Be sure that no ventilation slots are blocked.
y Disconnect main power before replacement or servicing.
y Make sure there is no flammable materials close to the unit while operating as it is fire
hazard.
y Use safety cable when fixes this unit. Don’t handle the unit by taking its head only, but
always by taking its base.
y Maximum ambient temperature is TA: 40℃. Don’t operate it where the temperature is
higher than this.
y Don’t touch the housing bare-hand during its operation. Turn off the power and allow
about 15 minutes for the unit to cool down before replacing or serving.
y In the event of serious operating problem, stop using the unit immediately. Never try to
repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or
malfunction. Please contact the nearest authorized technical assistance center. Always
use the same type spare parts.
y Do not touch any wire during operation as high voltage might be causing electric shock.
2A
19A
Warning
F. If The pan belt is broken
y To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or
1.
Turn off the mains power.
2.
Unscrew all the screws and open the base-housing cove.
y Do not open the unit within five minutes after switching off.
3.
Unplug all the connect wires that from the arm to PC board
y The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly
4.
Unscrew the screws that fix the axis gear.
5.
Change a new belt by going through all connect wires that from the arm to base, and
moisture.
through the bridge for correct position.
6.
Set up the gear axis to the bridge and screwed it. Note: do not press the belt.
7.
Put the belt around the axis gear and motor gear.
8.
Plug all the connect wires that form the arm to PC board
9.
Adjust the pan home position.
damaged.
Caution
There are no user serviceable parts inside the unit. Do not open the housing or attempt
any repairs yourself. In the unlikely event your unit may require service, please contact
your nearest dealer.
Installation
The unit should be mounted via its screw holes on the bracket. Always ensure that the
10. Screw the base-housing cover.
unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the
structure to which you are attaching the unit is secure and is able to support a weight of 20
kg for each unit.
18A
3A
2. Technical Specification
5. Troubleshooting
• The unit is DMX 512 fixture. It features full DMX 512 control. It can be also linked together
in master/slave connection, as many as required and run by built-in program chase
Following are a few common problems that may occur during operation. Here are
sequences automatically or by sound activation through an internal microphone to create
some suggestions for easy troubleshooting:
an intelligent effect.
• It can be operated by DMX 512 control or can be used as an individual unit without a
controller.
A. The unit does not work, no light and the fan does not work
1. Check the connection of power and main fuse.
• Features different preprogrammed chase patterns.
• Please use a cable when connecting units together.
• Accurate focusable optics system and ultra smooth stepping motors, Fan cooled.
2. Measure the mains voltage on the main connector.
3. Check the power on LED.
B. Not responding to DMX controller
• Pan: 540 deg. Tilt: 220 deg.
1. DMX LED should be on. If not, check DMX connectors, cables to see if link properly.
• Voltage: 100V/120V/230V/250V~50/60Hz
2. If the DMX LED is on and no response to the channel, check the address settings and
Light Source: Total: 18 LEDs, 6 Red, 6 Green, 6 Blue (CM-18Ⅱ)
Total: 36 LEDs, 12 Red, 12 Green, 12 Blue (CM-36Ⅱ)
Fuse: T 2A
DMX polarity.
3. If you have intermittent DMX signal problems, check the pins on connectors or on PCB
of the unit or the previous one.
4. Try to use another DMX controller.
Power Consumption: 56W (CM-18Ⅱ)
5. Check if the DMX cables run near or run alongside to high voltage cables that may
81W(CM-36Ⅱ)
• Dimension: 266 x 276 x 302 mm
cause damage or interference to DMX interface circuit.
• Weight: 9 kgs
C. Some units don’t respond to the easy controller
1. You may have a break in the DMX cabling. Check the LED for the response of the
master/ slave mode signal.
2.1 Change Beam Angle
2. Wrong DMX address in the unit. Set the proper address.
In this CM series, if you want to change the beam angle of fixture, you can change
D. No response to the sound
lens of the fixture as below.
1. Make sure the unit does not receive DMX signal.
Please refer to the photo below:
2. Check microphone to see if it is good by tapping the microphone
E. One of the channels is not working well
1. The stepper motor might be damaged or the cable connected to the PCB is broken.
2. The motor’s drive IC on the PCB might be out of condition.
4A
17A
4.5 DMX512 Connection
The DMX 512 is widely used in intelligent lighting control, with a maximum of 512 channels.
3. How To Set The Unit
3.1 Control Panel
1.
If you using a controller with 5 pins DMX output, you need to use a 5 to 3 pin
adapter-cable.
2.
At last unit, the DMX cable has to be terminated with a terminator. Solder a 120 ohm
1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it
in the DMX-output of the last unit.
3.
Connect the unit together in a `daisy chain` by XLR plug from the output of the unit to
the input of the next unit. The cable can not branched or split to a `Y` cable. DMX 512 is
a very high-speed signal. Inadequate or damaged cables, soldered joints or corroded
connectors can easily distort the signal and shut down the system.
4.
The DMX output and input connectors are pass-through to maintain the DMX circuit,
Display
when one of the units’ power is disconnected.
To show the various menus and the selected functions
5.
Each lighting unit needs to have an address set to receive the data sent by the
6.
The end of the DMX 512 system should be terminated to reduce signal errors.
DMX
On
DMX input present
7.
3 pin XLR connectors are more popular than 5 pin XLR.
MASTER
On
Master Mode
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
SLAVE
On
Slave Mode
5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
SOUND
Flashing
Sound activation
controller. The address number is between 0-511 (usually 0 & 1 are equal to 1).
LED
Pin4/5: Not used.
16A
5A
Button
MENU
To select the programming functions
DOWN
To go backward in the selected functions
UP
To go forward in the selected functions
ENTER
To confirm the selected functions
Mains input
IEC socket and integrated fuse holder, connect to main power cable.
Only for remote control
By connect to the 1/4’’ microphone jack to control the unit for Stand by, Function and Mode
function.
Sensitivity
To adjust the sound receiving sensitivity
DMX input/output
For DMX512 link, use 3-pin XLR plug cable to link the unit together.
3.2 Main Function
To select any of the given functions, press the MENU button up to when the required one is
showing on the display. Select the function by ENTER button and the display will blink. Use
DOWN and UP button to change the mode. Once the required mode has been selected,
press the ENTER button to setup or it will automatically return to the main functions without
any change after idling 8 seconds. To go back to the functions without any change press the
MENU button. The main functions are showing below:
6A
15A
4.4 DMX 512 Configuration
14A
7A
DMX 512 Address Setting
is showing on the display. Pressing ENTER
Press the MENU button up to when the
Stand By
Blackout the unit
Function
1. Sync. Strobe
button and the display will blink. Use DOWN and UP button to change the DMX512 address.
2. Two-light strobe
Once the address has been selected, press the ENTER button to setup (or automatically
3. Sound Strobe
Select Show
Fade Speed
1.Pan positioning
1-4
Fast
2.Tilt positioning
Middle
return to the main functions without any change after 8 seconds). To go back to the functions
without any change press the MENU button again.
3.Dimmer or Color
Slow
Mode
Sound (LED OFF)
LED Normal Blinking
LED ON
change
LED Fast Blinking
4.3 iLead Controller
Channel Mode
Press the MENU button up to when the
is shown on the display. Pressing ENTER
button and the display will blink. Use DOWN and UP button to select the (8 Channel) or
(15 Channel) mode. Once the mode has been selected, press the ENTER button to setup
(or automatically return to the main functions without any change after 8 seconds). To go
back to the functions without any change press the MENU button again.
♦ Consistent DMX configuration enable iMove to be linked together with iRock and iShow
and controlled at the same time.
♦ DMX address can be set remotely by iLead controller (Please refer to the user manual of
iLead controller). No need to calculate the DMX channels of each fixture in the chain.
♦ Automatic switching between DMX function and built-in stand alone programs.
Use universal DMX controller to control the units, you have to set DMX address from 1 to
Show Mode
512 channel so that the units can receive DMX signal.
is showing on the display. Pressing ENTER
Press the MENU button up to when the
button and the display will blink. Use DOWN and UP button to select the
(show 3) or
is showing on the display. Pressing ENTER
(show 1)
button and the display will blink. Use DOWN and UP button to change the DMX512 address.
(show 4) mode. Once the mode has
Once the address has been selected, press and keep ENTER button pressed up to when
been selected, press the ENTER button to setup (or automatically return to the main
the display stops blinking or storing automatically 8 seconds later. To go back to the
functions without any change after 8 seconds). To go back to the functions without any
functions without any change press the MENU button again. If you use please refer to the
change press the MENU button again.
following diagram to address your DMX512 channel for the first 4 units.
or
(show 2) or
Press the MENU button up to when the
Show 1 mode - Fixture is placed on the floor. Tilt movement angle 210°.
Show 2 mode - Fixture is fixed under ceiling. Tilt movement angle 90°.
8 channels:
Show 3 mode - Fixture is placed on the speaker, the spot is always projecting
to the audience’s direction; i.e in front of the stage. Pan
15 channels:
movement angel (left to right to left): 160°. Tilt movement
angel: 90° (60° above horizon; 30° below horizon.)
Show 4 mode - Fixture is fixed under ceiling. The spot is mainly projecting in
front of the stage. Pan movement angel (left to right to
left):160°.
DMX address can be setting remotely by IL-0824 controller. No need to calculate the DMX
channels of each fixture in the chain.
Tilt movement angel: 90° (vertically, front 75°;
back 15°)
8 channels:
8A
13A
3. By iLead controller (Please refer to the user guide of iLead) or universal DMX controller
Slave Mode
No need to turn the unit off when you change the DMX address, as new DMX address
setting will be effected at once. Every time you turn the unit on, it will show the type on the
Press the MENU button up to when the
display and move all the motors to their ‘home’ position and you may hear some noises for
ENTER button and the display will blink. Use DOWN and UP button to select the
about 20 seconds. After that the unit will be ready to receive DMX signal or run the built in
(normal) or
(2 light show) mode. Once the mode has been selected, press the
ENTER button to setup (or automatically return to the main functions without any change
programs.
is showing on the display. Pressing
after 8 seconds). To go back to the functions without any change press the MENU button
4.1 Master/Slave Built In Preprogrammed Function
again.
By linking the units in master/slave connection, the first unit will control the other units to
Sound Mode
give an automatic, sound activated, synchronized light show. This function is good when you
want an instant show. You have to set the first unit in master mode
(show 1) or
(show 2) or
(show 3) or
and select
(show 4) mode. Its
Press the MENU button until the
is showing on the display. Pressing ENTER button
and the display will blink. Use DOWN and UP button to select the
DMX input jack will have nothing plugged into it, and Its master LED will be constantly on
(sound on) or
(sound off) mode. Once the mode has been selected, press the ENTER button to
and sound LED will flash to the music. The other units will have to set in slave mode
setup (or automatically return to the main functions without any change after 8 seconds). To
and select
go back to the functions without any change press the MENU button again.
(normal) or
(2 light show) mode, Their DMX cables plugged into
the DMX input jacks (daisy chain) and the slave led lights will constantly on.
Blackout Mode
2-light show
In
(slave mode),
means the unit works normally and
means
2-light show. In order to create a great light show, you can set
on the second unit to
get contrast movement to each other, even if you have two units only.
is showing on the display. Pressing
Press the MENU button up to when the
ENTER button and the display will blink. Use DOWN and UP button to select the
(yes blackout) or
(no blackout) mode. Once the mode has been selected, press the
ENTER button to setup (or automatically return to the main functions without any change
after 8 seconds). To go back to the functions without any change press the MENU button
4.2 Easy Controller
again.
The easy remote control is used only in master/slave mode. By
Pan Inversion
connecting to the 1/4” microphone jack of the first unit, you will find
that the remote control on the first unit will control all the other units
Press the MENU button up to when the
functions press the MENU button again.
button and the display will blink. Use DOWN and UP button to select the
or
is showing on the display. Pressing ENTER
(normal)
(pan inversion) mode. Once the mode has been selected, press the ENTER
button to setup (or automatically return to the main functions without any change after 8
seconds). To go back to the functions without any change press the MENU button again.
12A
9A
is blinking on the display. Pressing ENTER
Press the MENU button up to when the
Tilt Inversion
button and the display will show the temperature of the unit. To go back to the functions
is showing on the display. Pressing
Press the MENU button up to when the
press the MENU button again.
ENTER button and the display will blink. Use DOWN and UP button to select the
(normal) or
(tilt inversion) mode. Once the mode has been selected, press the
ENTER button to setup (or automatically return to the main functions without any change
Fixture Hours
after 8 seconds). To go back to the functions without any change press the MENU button
Press the MENU button up to when the
again.
button and the display will show the number of working hours of the unit. To go back to the
is blinking on the display. Pressing ENTER
functions press the MENU button again.
Led Display
is showing on the display. Pressing
Press the MENU button up to when the
Software version
ENTER button and the display will blink. Use DOWN and UP button to select the
Press the MENU button up to when the
(Led on) or
button and the display will show the version of software of the unit. To go back to the
(Led off) mode. Once the mode has been selected, press the ENTER
button to setup (or automatically return to the main functions without any change after 8
is blinking on the display. Pressing ENTER
functions press the MENU button again.
seconds). To go back to the functions without any change press the MENU button again.
Reset
Test
is blinking on the display. Pressing ENTER
Press the MENU button up to when the
is show on the display.
Press MENU button up to when the
Pressing ENTER button and the unit will run Self test by built-in program and can test by
button and all channels of the unit will return to their standard position. To go back to the
functions without any change press the MENU button again.
program. Back to the functions press MENU button again.
3.3 Home Position Adjust
Press Enter button for at least 5 seconds into offset mode to adjust the home position, use
Manual Test
DOWN and UP button up to the function (Pan, Tilt, B-red, B-green, B-blue) shown on the
is showing on the display. Pressing
Press the MENU button up to when the
ENTER button and the display will blink. Use DOWN and UP button to select the
. Once the mode has been selected,
press the ENTER button to confirm and use DOWN and UP button to test (or automatically
display. Pressing ENTER button and the display will blink. Use DOWN and UP button to
adjust the home position. Once the position has been selected, press the ENTER button to
setup or automatically return to the offset functions without any change press the MENU
button again, To go back to the main functions without any change after 8 seconds.
return to the main functions without any change after 8 seconds). To go back to the functions
without any change press the MENU button again.
4. How To Control The Unit
You can operate the unit in three ways:
1. By master/slave built-in preprogram function
Temperature Test
2. By easy controller
10A
11A
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF