Round flow cassette_ECPEN13-110_Catalogues_English

Round flow cassette_ECPEN13-110_Catalogues_English

» High COP cassette

ensures top performance

» 360° air discharge

» Auto-cleaning cassette

» Even more comfort

by avoiding draught

» Cold feet

become history

» Flexibility to suit any

room lay-out

Air Conditioners

Heating & Cooling

R ound flow cassette

FCQ(H)G,FXFQ

w w w . d a i k i n . e u

Replacement technology

Round flow cassette

Setting the standard for efficiency and comfort

Whether we’re talking about a shop, office or small public area, getting the heating and cooling right is a performance imperative, and for optimal performance you need optimal comfort in terms of temperature, humidity and air flow. To deliver this, you need the Daikin round flow cassette as part of the solution.

Optimal comfort

To achieve optimal comfort you need the perfect distribution of air at the right temperature.

This distribution must reach all parts of the room with no dead areas, but, at the same time, with no draughts or cold spots. This is where the

360°

air flow discharge pattern of the round flow cassette, combined with its optional sensors and special features, really delivers.

• The round flow cassette delivers air through four

individually controllable flaps

to ensure that the air reaches all parts of the room.

• The optional

presence sensor

detects when people are in the room and directs the air flow away from them to minimize draughts - this is ideal for rooms and offices used by people who are stationary when there.

• The optional

floor sensor

ensures that cold feet are history. The sensor detects the average floor temperature and ensures an even temperature distribution between ceiling and floor.

• The outflow louvres are controllable to ensure an even distribution of air and temperature throughout the room and can be set to

minimize draughts

and to prevent ceiling soiling.

• In addition, the round flow cassette has a special dry programme to maintain the humidity at the most efficient level and its whisperquiet operation, barely more than the sound of rustling leaves, ensures that your customers and staff can attend to their work undisturbed.

infrared presence sensor infrared floor sensor

Top efficiency

As you would expect from Daikin, the round flow cassette is one of the top performing cassettes on the market. With a high COP and an

A++

energy rating for both heating and cooling, it has two important features that help deliver superior efficiency.

Standard auto-cleaning feature

Keeping the filters clean is a critical contributory factor to high efficiency and we have incorporated a fully automatic daily cleaning feature within the standard panel to ensure this is done without you having to remember. Compared to standard solutions, this has been found to reduce energy consumption by up to 50% and helps facilitate routine maintenance.

Auto-cleaning panel

saves up to

50%

9000

8000

7000

6000

5000

Optional presence sensor

3000

1000

9000

8000

7000

6000

5000

4000

3000

2000

1000

0 empty for 15 minutes and then switches it back to normal when someone enters. This feature has been shown to reduce energy consumption by up to 27% compared to a system without a sensor.

When the room has been empty for 15 minutes, the sensor maintains a reduced pre-set temperature for heating and a raised pre-set temperature when in cooling mode for up to an hour before switching off. This ensures that when people enter after a short absence the energy consumed in returning to the optimal temperature is kept to a minimum.

Presence sensor

saves up to

27%

*

Energy consumption (kWh)

Cumulative energy comparison over 12 months

9000

8000

(Test site, Wolverhampton, UK)

7000

6000

5000

4000

3000

50% difference in electricity consumption

2000

1000

0

July

August

Sept emberOct ober

No vember

December

Januar y

Februar y

Mar ch

Apr il

May June July

Auto cleaning cassette

Standard round flow cassette

Without sensor

26°

24°

22°

Nobody in the room

Cooling

Set point: 22° CDB

20°

time

09.00

09.30 10.00 10.30 11.00 11.30 12.00 12.30 13.00 13.30 14.00 14.30 15.00 15.30 16.00 16.30 17.00

With sensor (BRC1E52A/B required)

26°

24°

22° no presence detected for 15mins

20°

time

09.00

09.30 10.00 10.30 11.00 11.30 12.00 12.30 13.00 13.30 14.00 14.30 15.00 15.30 16.00 16.30 17.00

Flexible installation

To provide you with as much flexibility as possible in installing the system or changing the layout of your rooms, we have incorporated a number of set-up features to ensure that the cassette delivers optimally no matter what interior design conditions occur.

Closable flaps facilitate the re-design of your layout

Each of the eight flaps can be closed individually using the wired controller and this gives up to 23 different air flow patterns without loss of efficiency or comfort. This facility allows you the maximum flexibility in re-designing your interior layout without the need to re-locate the cassette - if the re-design means the cassette is close to a wall or a corner, you simply close the flaps affected.

Cool or heat up small to large applications with a single outdoor unit

A single Daikin outdoor unit can power up to nine cassettes which can be fitted in a variety of combinations. Most rooms will use a single, individually-controlled cassette but large or irregular rooms can use a combination of up to four cassettes that are controlled as a group. This delivers optimal efficiency and comfort in each space.

For larger commercial buildings a VRV system can be used, connecting up to 64 units to a single outdoor unit.

Change room configuration/refurbishment

Total control

Daikin’s enhanced wired controller with its advanced functionality gives you total control over all the functions and settings of the round flow cassette thus enabling you to select optimal comfort settings, establish the highest levels of efficiency and obtain the lowest operating costs. It even displays kWh usage by day, month and year allowing you monitor your energy consumption and so control costs.

The controller has three programmable schedules - for example:

› winter for optimal heating

› summer for optimal cooling

› a spring/autumn for more flexible settings

In addition, there is a holiday function that allows you to override and disable the scheduled timer so that you don’t waste money during the time the building is unoccupied.

Wired remote control

BRC1E52A/B

(optional)

Controller features:

› Temperature range limit

› Improved setback function

› Support for presence and floor sensor

› Off timer

› kWh indication

› 3 weekly timers

Home leave operation

Fan only Auto-cleaning panel

Draught prevention

Whisper quiet

Auto coolingheating changeover

Air filter Dry programme

Ceiling soiling prevention

Vertical auto swing

Fan speed

3 steps

Weekly timer Infrared remote control

Wired remote control

Centralised control

Auto-restart Selfdiagnosis

Drain pump kit (standard) twin/triple/ double twin application

(FCQ(H)G)

Multi model application

(FCQG)

VRV for residential application

(FCQG)

Multi tenant

(FXFQ)

Replacement technology

Technical

Specifications

Fully integrated solutions for medium to large commercial environments connecting up to 64 indoor units to a single system, all individually controlled.

• Perfect comfort by simultaneous heating spaces, while cooling others

• Free heating of rooms or water possible by heat recovery

• Temperature control, fresh air, air curtains and hot water production all integrated in a single system

INDOOR UNIT

Cooling capacity Nom.

Heating capacity Nom.

Power input -

50Hz

Cooling

Heating

Dimensions

Weight

Decoration panel

Unit

Unit

Model

Colour

Fan-Air flow rate

- 50Hz

Dimensions

Weight

Cooling

Heating

Sound power level Cooling

Sound pressure level

Cooling

Heating

Power supply

Current - 50Hz

Nom.

Nom.

Refrigerant Type

Piping connections Liquid/OD/Gas/OD/Drain kW kW kW kW

HeightxWidthxDepth mm kg

HeightxWidthxDepth mm kg

High/Nom./Low

High/Nom./Low m³/min m³/min

High/Nom.

High/Nom./Low

High/Nom./Low

Phase/Frequency/Voltage

Maximum fuse amps (MFA) dBA dBA dBA mm

Hz/V

A

FXFQ20A FXFQ25A FXFQ32A FXFQ40A FXFQ50A FXFQ63A FXFQ80A FXFQ100A FXFQ125A

2.2

2.5

2.8

3.2

19

0.038

0.038

12.5/10.6/8.8

12.5/10.6/8.8

49/-

31/29/28

31/29/28

3.6

4.0

4.5

5.0

5.6

6.3

0.053

7.1

8.0

0.061

9.0

10.0

0.092

11.2

12.5

0.115

0.053

0.061

204x840x840

20 21

BYCQ140D7W1 / BYCQ140D7W1W / BYCQ140D7GW1

0.092

0.115

246x840x840

24

Pure White (RAL 9010)

60x950x950 / 60x950x950 / 145x950x950

14.0

16.0

0.186

0.186

288x840x840

26

5.4 / 5.4 / 10.3

13.6/11.6/9.5 15.0/12.8/10.5 16.5/13.5/10.5 22.8/17.6/12.4 26.5/19.5/12.4 33.0/26.5/19.9

13.6/11.6/9.5 15.0/12.8/10.5 16.5/13.5/10.5 22.8/17.6/12.4 26.5/19.5/12.4 33.0/26.5/19.9

51/-

33/31/29

33/31/29

R-410A

53/-

35/33/30

35/33/30

55/-

38/34/30

38/34/30

60/-

43/37/30

43/37/30

61/-

45/41/36

45/41/36

6.35/12.7/VP25 (O.D. 32 / I.D. 25)

1~/50/60/220-240/220

16

9.52/15.9/VP25 (O.D. 32 / I.D. 25)

(1) The BYCQ140D7W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140D7W1W decoration panel in environments exposed to concentrations of dirt.

(2) BYCQ140D7W1: pure white standard panel with grey louvers; BYCQ140D7W1W: pure white standard panel with white louvers; BYCQ140D7GW1: pure white auto cleaning panel.

FXFQ-A BRC1E52A/B BRC7A532F VRV outdoor

Heating & Cooling

Perfect for light commercial applications

INDOOR UNIT FCQHG71F FCQHG100F FCQHG125F FCQHG140F FCQHG71F FCQHG100F FCQHG125F FCQHG140F

Cooling capacity Min./Nom./Max.

Heating capacity Min./Nom./Max.

Seasonal efficiency

(according to

EN14825)

Nominal efficiency

(cooling at 35°/27° nominal load, heating at 7°/20° nominal load)

Casing

Dimensions

Weight

Cooling

Heating

(Average climate)

EER

COP

Annual energy consumption

Energy label

Colour

Unit

Unit

Decoration panel Model

Colour

Dimensions

Weight

Fan - Air flow rate Cooling

Cooling/Heating kW kW

Energy label

Pdesign kW

SEER

Annual energy consumption kWh

Energy label

Pdesign kW

SCOP

Annual energy consumption kWh kWh

-/6.8/-

-/7.5/-

6.80

340

A+

7.60

4.54

2,343

4.09

4.80

830

7.00

-/9.5/-

-/10.8/-

A++

9.50

475

11.30

4.80

3,295

4.42

4.99

1,075

A/A

A++

-/12.0/-

-/13.5/-

12.00

6.61

635

12.66

4.63

3,829

4.00

4.40

1,500

-/13.4/-

-/15.5/-

-

-

-/6.8/-

-/7.5/-

6.80

-

-

-

-

340

A+

7.60

4.54

-

-

3.35

4.12

2,000

-/-

-

288x840x840

2,343

4.09

4.80

830

7.00

-/9.5/-

-/10.8/-

A++

9.50

475

11.30

4.80

3,295

4.42

4.99

1,075

A/A

A++

-/12.0/-

-/13.5/-

12.00

6.61

635

12.66

4.63

3,829

4.00

4.40

1,500

-

-

-

-

-/13.4/-

-/15.5/-

-

-

-

-

3.35

4.12

2,000

-/-

HeightxWidthxDepth mm kg 25 26 25

BYCQ140D7W1 / BYCQ140D7W1W / BYCQ140D7GW1

26

HeightxWidthxDepth mm kg

Pure White (RAL 9010) / Pure White (RAL 9010) /

60x950x950 / 950x60x950 / 145x950x950

5.4 / 5.4 / 10.3

High/Nom./Low m³/min 21.2/16.7/12.2 32.3/25.7/19.0 33.5/26.7/19.9 33.5/27.3/21.1 21.2/16.7/12.2 32.3/25.7/19.0 33.5/26.7/19.9 33.5/27.3/21.1

Heating

Sound power level Cooling

Heating

Sound pressure level

Piping connections

Power supply

Cooling

Heating

Liquid

Gas

High/Nom./Low

High

High

High/Nom./Low

High/Nom./Low

OD

OD

Phase / Frequency / Voltage m³/min 21.2/16.7/12.2 32.3/25.7/19.0 33.5/26.7/19.9 33.5/27.3/21.1 21.2/16.7/12.2 32.3/25.7/19.0 33.5/26.7/19.9 33.5/27.3/21.1

dBA dBA dBA dBA mm mm

Hz / V

53

53

36/33/29

36/33/29

44/39/33

44/39/33

61

61

45/40/35

45/40/35

45/41/37

45/41/37

9.52

15.9

53

53

36/33/29

36/33/29

1~ / 50 / 220-240

44/39/33

44/39/33

61

61

45/40/35

45/40/35

45/41/37

45/41/37

OUTDOOR UNIT

Dimensions

Weight

Unit

Unit

Fan - Air flow rate Cooling

Heating

HeightxWidthxDepth mm kg

Nom.

Nom.

m³/min m³/min

Sound power level Cooling

Sound pressure level

Cooling

Heating

Nom.

Nom.

Nom.

Night quiet mode Level 1

Operation range Cooling

Heating dBA dBA dBA dBA

Ambient Min.~Max. °CDB

Ambient Min.~Max. °CWB

Refrigerant

Piping connections

Type/GWP

Piping length OU - IU Max.

m

System Equivalent m

Level difference IU - OU Max.

IU - IU Max.

m m

Power supply

Current - 50Hz

Phase / Frequency / Voltage

Maximum fuse amps (MFA)

Hz / V

A

RZQG71L8V1 RZQG100L8V1 RZQG125L8V1 RZQG140L7V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1

990x940x320

78

59

49

64

48

50

43

50

70

66

50

52

70

1,430x940x320

102

62

67

51

45

75

90

53

84

69

52

990x940x320

80

59

49

64

48

50

43

-15~50

-20~15.5

R-410A/1,975

30.0

0.5

50

70

66

50

52

70

1,430x940x320

101

62

67

51

45

75

90

53

84

69

52

20

1~ / 50 / 220-240

32 16

3N~ / 50 / 380-415

20

(1) EER/COP according to Eurovent 2012 (2) The BYCQ140D7W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140D7W1W decoration panel in environments exposed to concentrations of dirt. (3) BYCQ140D7W1: pure white standard panel with grey louvers; BYCQ140D7W1W: pure white standard panel with white louvers; BYCQ140D7GW1: pure white auto cleaning panel.ww

FCQHG71-140F BRC1E52A/B BRC7FA532F RZQG100-140L8/7V1/L(8)Y1

Heating & Cooling

Perfect for light commercial applications

INDOOR UNIT

Cooling capacity

Heating capacity

Seasonal efficiency

(according to

EN14825)

Nominal efficiency

(cooling at 35°/27° nominal load, heating at 7°/20° nominal load)

Min./Nom./Max.

Min./Nom./Max.

Cooling kW kW

Energy label

Pdesign kW

SEER

Annual energy consumption kWh

Heating

(Average climate)

Energy label

Pdesign kW

SCOP

Annual energy consumption kWh

EER

COP

Annual energy consumption

Energy label Cooling/Heating kWh

Casing

Dimensions

Weight

Decoration panel 1

Decoration panel 2

Decoration panel 3

Colour

Unit

Unit

Model

Colour

Dimensions

HeightxWidthxDepth mm kg

Weight

Fan - Air flow rate Cooling

Heating

Sound power level Cooling

Heating

Sound pressure level

Cooling

Heating

Piping connections

Power supply

Liquid

Gas

HeightxWidthxDepth mm kg

High/Nom./Low m³/min

High/Nom./Low m³/min

High

High

High/Nom./Low

High/Nom./Low

OD

OD

Phase / Frequency / Voltage dBA dBA dBA dBA mm mm

Hz / V

FCQHG71F

-/6.8/-

-/7.5/-

6.80

6.50

366

7.60

4.15

2,563

3.50

4.10

1,059

25

21.2/16.7/12.2

21.2/16.7/12.2

53

53

36/33/29

36/33/29

A++

FCQHG100F

-/9.5/-

-/10.8/-

9.50

6.70

496

A+

4.30

2,614

3.70

4.30

1,285

A/A

8.03

FCQHG125F

-/12.0/-

-/13.5/-

A

12.00

5.40

777

4.10

2,741

3.23

3.75

1,855

FCQHG140F

-/13.4/-

-/15.5/-

-

-

-

-

-

-

-

-

3.21

3.61

2,085

-/-

-

288x840x840

FCQHG100F

-/9.5/-

-/10.8/-

A++

9.50

6.70

496

4.30

2,614

3.70

4.30

1,285

A+

8.03

A/A

FCQHG125F

-/12.0/-

-/13.5/-

A

12.00

5.40

777

4.10

2,741

3.23

3.75

1,855

26

BYCQ140D7W1 / BYCQ140D7W1W / BYCQ140D7GW1

Pure White (RAL 9010) / Pure White (RAL 9010) / Pure White (RAL 9010)

60x950x950 / 950x60x950 / 145x950x950

32.3/25.7/19.0

32.3/25.7/19.0

33.5/26.7/19.9

33.5/26.7/19.9

5.4 / 5.4 / 10.3

33.5/27.3/21.1

33.5/27.3/21.1

32.3/25.7/19.0

32.3/25.7/19.0

33.5/26.7/19.9

33.5/26.7/19.9

44/39/33

44/39/33

45/40/35

45/40/35

45/41/37

45/41/37

9.52

15.9

1~ / 50 / 220-240

61

61

44/39/33

44/39/33

45/40/35

45/40/35

33.5/27.3/21.1

33.5/27.3/21.1

45/41/37

45/41/37

FCQHG140F

-/13.4/-

-/15.5/-

-

-

-

-

-

-

-

-

3.21

3.61

2,085

-/-

OUTDOOR UNIT

Dimensions

Weight

Unit

Unit

Fan - Air flow rate Cooling

Sound pressure level

Heating

Sound power level Cooling

Cooling

Heating

HeightxWidthxDepth mm

Nom.

Nom.

Nom.

kg m³/min m³/min

Nom./Silent operation dBA

Nom.

Night quiet mode Level 1 dBA dBA dBA

Operation range Cooling

Heating

Ambient Min.~Max. °CDB

Ambient Min.~Max. °CWB

Refrigerant

Piping connections

Type/GWP

Piping length OU - IU Max.

m

System Equivalent m

Level difference IU - OU Max.

IU - IU Max.

m m

Power supply

Current - 50Hz

Phase / Frequency / Voltage

Maximum fuse amps (MFA)

Hz / V

A

RZQSG71L3V1 RZQSG100L8V1 RZQSG125L8V1 RZQSG140LV1 RZQSG100L8Y1 RZQSG125L8Y1 RZQSG140LY1

770x900x320 990x940x320 1,430x940x320 990x940x320 1,430x940x320

67

52 76

81

77

102

83 76

82

77

101

83

83 62 83 48

65

49/47

51

69

53/49

57

-

70

54/49

58

53/49

54

69

53/-

57

70

54/-

58

49

62

69

53/-

54

-5.0~46

30

40

15

-15~15.5

R-410A/1,975

-5~46

50

70

30.0

0.5

20

1~ / 50 / 220-240

32

3N~ / 50 / 380-415

20

(1) EER/COP according to Eurovent 2012 (2) The BYCQ140D7W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140D7W1W decoration panel in environments exposed to concentrations of dirt. (3) BYCQ140D7W1: pure white standard panel with grey louvers; BYCQ140D7W1W: pure white standard panel with white louvers; BYCQ140D7GW1: pure white auto cleaning panel.

FCQHG71-140F BRC1E52A/B BRC7FA532F

RZQSG140LV1

Heating & Cooling

Perfect for light commercial applications

INDOOR UNIT FCQG71F FCQG100F FCQG125F FCQG140F FCQG71F FCQG100F FCQG125F FCQG140F

Cooling capacity Min./Nom./Max.

Heating capacity Min./Nom./Max.

Seasonal efficiency

(according to

EN14825)

Cooling

Nominal efficiency

(cooling at 35°/27° nominal load, heating at 7°/20° nominal load)

Heating

(Average climate)

EER

COP

Annual energy consumption

Energy label Cooling/Heating kW kW

Energy label

Pdesign kW

SEER

Annual energy consumption kWh

Energy label

Pdesign kW

SCOP

Annual energy consumption kWh kWh

-/6.8/-

-/7.5/-

6.80

350

A+

6.33

4.20

2,110

3.39

3.97

1,005

A++

6.80

-/9.5/-

-/10.8/-

9.50

488

A++

11.30

4.61

3,431

3.87

4.15

1,225

A/A

-/12.0/-

-/13.5/-

A+

12.00

6.00

700

A+

12.66

4.10

4,322

3.73

3.63

1,610

-/13.4/-

-/15.5/-

-

-

-

-

-

-

-

-

3.21

3.61

2,085

-/--/-

-/6.8/-

-/7.5/-

6.80

350

A+

6.33

4.20

2,110

3.39

3.97

1,005

A++

6.80

-/9.5/-

-/10.8/-

9.50

488

A++

11.30

4.61

3,431

3.87

4.15

1,225

A/A

-/12.0/-

-/13.5/-

A+

12.00

6.00

700

A+

12.66

4.10

4,322

3.73

3.63

1,610

-/13.4/-

-/15.5/-

-

-

3.21

3.61

Casing

Dimensions

Weight

Colour

Unit

Unit

Decoration panel Model

Colour

Dimensions

Weight

Fan - Air flow rate Cooling

Heating

Sound power level Cooling

Sound pressure level

Piping connections

Power supply

Heating

Cooling

Heating

Liquid

Gas

HeightxWidthxDepth mm kg

HeightxWidthxDepth mm kg

204x840x840

21

High/Nom./Low m³/min 15.0/12.1/9.1 22.8/17.6/12.4

High/Nom./Low

High

High m³/min dBA dBA

High/Nom./Low dBA

High/Nom./Low

OD

OD

Phase / Frequency / Voltage dBA mm mm

Hz / V

15.0/12.1/9.1

51

51

33/31/28

33/31/28

22.8/17.6/12.4

54

54

37/33/29

37/33/29

246x840x840

24

--

BYCQ140D7W1 / BYCQ140D7W1W / BYCQ140D7GW1

Pure White (RAL 9010) / Pure White (RAL 9010) / Pure White (RAL 9010)

60x950x950 / 950x60x950 / 145x950x950

26.0/19.2/12.4

26.0/19.2/12.4

58

58

41/35/29

41/35/29

9.52

15.9

204x840x840

5.4 / 5.4 / 10.3

21

15.0/12.1/9.1 22.8/17.6/12.4

15.0/12.1/9.1

51

51

33/31/28

33/31/28

1~ / 50 / 220-240

22.8/17.6/12.4

54

54

37/33/29

37/33/29

246x840x840

24

26.0/19.2/12.4

26.0/19.2/12.4

58

58

41/35/29

41/35/29

-

-

-

-

-

-

2,085

-/-

OUTDOOR UNIT

Dimensions

Weight

Unit

Unit

Fan - Air flow rate Cooling

Heating

HeightxWidthxDepth mm kg

Nom.

Nom.

m³/min m³/min

Sound power level Cooling

Sound pressure level

Cooling

Heating

Nom.

Nom.

Nom.

Night quiet mode Level 1

Operation range Cooling

Heating dBA dBA dBA dBA

Ambient Min.~Max. °CDB

Ambient Min.~Max. °CWB

Refrigerant

Piping connections

Type/GWP

Piping length OU - IU Max.

m

System Equivalent m

Level difference IU - OU Max.

m

Power supply

Current - 50Hz

IU - IU Max.

Phase / Frequency / Voltage

Maximum fuse amps (MFA) m

Hz / V

A

RZQG71L8V1 RZQG100L8V1 RZQG125L8V1 RZQG140L7V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1

990x940x320

78

59

49

64

48

50

43

50

70

66

50

52

70

1,430x940x320

102

62

67

51

45

75

90

53

84

69

52

990x940x320

80

59

49

64

48

50

43

-15~50

-20~15.5

R-410A/1,975

30.0

0.5

50

70

66

50

52

70

1,430x940x320

101

62

67

51

45

75

90

53

84

69

52

20

1~ / 50 / 220-240

32 16

3N~ / 50 / 380-415

20

(1) EER/COP according to Eurovent 2012 (2) The BYCQ140D7W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140D7W1W decoration panel in environments exposed to concentrations of dirt. (3) BYCQ140D7W1: pure white standard panel with grey louvers; BYCQ140D7W1W: pure white standard panel with white louvers; BYCQ140D7GW1: pure white auto cleaning panel.

FCQG100-140F BRC1E52A/B BRC7AF532F RZQG100-140L8/7V1/L(8)Y1

RZQG100-140L8/7V1/L(8)Y1

Heating & Cooling

INDOOR UNIT

Cooling capacity

Heating capacity

Seasonal efficiency

(according to

EN14825)

Power supply

Min./Nom./Max.

Min./Nom./Max.

Cooling kW kW

Energy label

Pdesign kW

SEER

Annual energy consumption kWh

Nominal efficiency

(cooling at 35°/27° nominal load, heating at 7°/20° nominal load)

Casing

Dimensions

Weight

Sound pressure level

Heating

(Average climate)

Energy label

Pdesign kW

SCOP

Annual energy consumption kWh

EER

COP

Annual energy consumption

Energy label Cooling/Heating

Colour

Unit

Unit

Decoration panel Model

Colour

Dimensions

Weight

Fan - Air flow rate Cooling

Heating

Sound power level Cooling

Heating

Cooling

Heating

HeightxWidthxDepth mm

HeightxWidthxDepth mm

High/Nom./Low m³/min

High/Nom./Low m³/min

High

High

High/Nom./Low

High/Nom./Low kWh kg kg dBA dBA dBA dBA

Piping connections

Liquid

Gas

OD

OD

Phase / Frequency / Voltage mm mm

Hz / V

Perfect for light commercial applications

FCQG71F

-/6.8/-

-/7.5/-

6.80

6.10

390

6.33

2,162

3.21

3.61

971

A/A

204x840x840

21

15.0/12.1/9.1

15.0/12.1/9.1

51

51

33/31/28

33/31/28

A++

4.10

FCQG100F

-/9.5/-

-/10.8/-

9.50

6.50

511

A+

7.60

2,595

3.30

3.54

1,440

A/B

FCQG125F

-/12.0/-

-/13.5/-

A

12.00

5.30

792

8.03

4.01

2,803

3.21

1,870

3.41

FCQG140F

-/13.4/-

-/15.5/-

-

-

-

-

-

FCQG100F

-/9.5/-

-/10.8/-

A++

9.50

6.50

511

-

-

-

3.01

7.60

4.10

2,595

3.30

2,225

-/-

-

246x840x840

24

3.54

1,440

A+

A/B

FCQG125F

-/12.0/-

-/13.5/-

BYCQ140D7W1 / BYCQ140D7W1W / BYCQ140D7GW1

Pure White (RAL 9010) / Pure White (RAL 9010) / Pure White (RAL 9010)

60x950x950 / 950x60x950 / 145x950x950

5.4 / 5.4 / 10.3

22.8/17.6/12.4

22.8/17.6/12.4

54

54

37/33/29

37/33/29

26.0/19.2/12.4

26.0/19.2/12.4

58

58

41/35/29

41/35/29

22.8/17.6/12.4

22.8/17.6/12.4

54

54

37/33/29

37/33/29

9.52

15.9

1~ / 50 / 220-240

A

12.00

5.30

792

8.03

4.01

2,803

3.21

1,870

3.41

26.0/19.2/12.4

26.0/19.2/12.4

58

58

41/35/29

41/35/29

FCQG140F

-/13.4/-

-/15.5/-

-

-

-

-

-

-

-

-

3.01

2,225

-/-

OUTDOOR UNIT

Dimensions

Weight

Unit

Unit

Fan - Air flow rate Cooling

Sound pressure level

Heating

Sound power level Cooling

Cooling

Heating

HeightxWidthxDepth mm

Nom.

Nom.

Nom.

kg m³/min m³/min

Nom./Silent operation dBA

Nom.

Night quiet mode Level 1 dBA dBA dBA

Operation range Cooling

Heating

Refrigerant

Piping connections

Type/GWP

Piping length

Ambient Min.~Max. °CDB

Ambient Min.~Max. °CWB

OU - IU Max.

m

System Equivalent m

Power supply

Current - 50Hz

Level difference IU - OU Max.

IU - IU Max.

Phase / Frequency / Voltage

Maximum fuse amps (MFA) m m

Hz / V

A

RZQSG71L3V1 RZQSG100L8V1 RZQSG125L8V1 RZQSG140LV1 RZQSG100L8Y1 RZQSG125L8Y1 RZQSG140LY1

770x900x320 990x940x320 1,430x940x320 990x940x320 1,430x940x320

67

52 76

81

77

102

83 76

82

77

101

83

83 62 83 48

65

49/47

51

69

53/49

57

-

70

54/49

58

53/49

54

69

53/-

57

70

54/-

58

49

62

69

53/-

54

-5.0~46

30

40

15

20

1~ / 50 / 220-240

32

-5~46

-15~15.5

R-410A/1,975

50

70

30.0

0.5

3N~ / 50 / 380-415

20

(1) EER/COP according to Eurovent 2012 (2) The BYCQ140D7W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140D7W1W decoration panel in environments exposed to concentrations of dirt. (3) BYCQ140D7W1: pure white standard panel with grey louvers; BYCQ140D7W1W: pure white standard panel with white louvers; BYCQ140D7GW1: pure white auto cleaning panel.

FCQG100-140F BRC1E52A/B BRC7AF532F

RZQSG140LV1

Heating & Cooling

Perfect for light commercial applications

INDOOR UNIT

Cooling capacity efficiency

(according to

EN14825)

Min./Nom./Max.

Heating capacity Min./Nom./Max.

Seasonal Cooling

Heating

(Average climate) kW kW

Energy label

Pdesign kW

SEER

Annual energy consumption kWh

Energy label

Pdesign

SCOP kW

Annual energy consumption kWh

Nominal efficiency

(cooling at 35°/27° nominal load, heating at 7°/20° nominal load)

Casing

Dimensions

Weight

EER

COP

Annual energy consumption

Energy label

Colour

Unit

Unit

Decoration panel Model

Colour

Cooling/Heating kWh

HeightxWidthxDepth mm kg

Dimensions

Weight

Fan - Air flow rate Cooling

Heating

HeightxWidthxDepth mm

High/Nom./Low

High/Nom.

kg m³/min m³/min

Sound power level Cooling

Heating

Sound pressure level

Cooling

Heating

Piping connections

Power supply

Liquid

Gas

High

High

OD

OD

Phase / Frequency / Voltage dBA dBA

High/Nom./Low dBA

High/Nom./Low dBA mm mm

Hz / V

FCQG35F

-/3.4/-

-/4.2/-

A

3.50

5.34

230

A++

3.32

4.74

981

3.58

5.34

475

A/B

18

12.5/10.6/8.7

12.5/10.6

9.5

FCQG50F

-/5.0/-

-/6.0/-

A+

5.00

5.89

297

A+

4.36

4.24

1,442

3.55

3.70

705

A/A

-

204x840x840

19

BYCQ140D7W1/BYCQ140D7W1W/BYCQ140D7GW1

49

49

31/29/27

31/29/27

Pure White (RAL 9010)

60x950x950/60x950x950/145x950x950

5.4/5.4/10.3

12.6/10.7/8.7

12.6/10.7

6.35

12.7

1~ / 50 / 220-240

FCQG60F

-/5.7/-

-/7.00/-

5.70

5.74

347

A

4.71

3.87

1,702

3.48

3.52

820

A/B

13.6/11.2/8.7

13.6/11.2

51

51

33/31/28

33/31/28

OUTDOOR UNIT

Dimensions

Weight

Unit

Unit

Fan - Air flow rate Cooling

Heating

Sound power level Cooling

Sound pressure Cooling

Power supply

Current - 50Hz

HeightxWidthxDepth mm kg

High/Low

High/Low

Nom./High

High/Low m³/min m³/min dBA dBA level Heating

Operation range Cooling

Refrigerant

Piping connections

Heating

Type/GWP

Piping length

High/Low

OU - IU Max.

Level difference IU - OU Max.

dBA

Ambient Min.~Max. °CDB

Ambient Min.~Max. °CWB m m

Phase / Frequency / Voltage

Maximum fuse amps (MFA)

Hz / V

A

RXS35K

550x765x285

34

36.0/30.1

28.3/25.6

20

15

10

48/44

48/45

RXS50K

50.9/48.9

45.0/43.1

-/63

-10~46

-15~18

R-410A/1,975

1~ / 50 / 220-240

735x825x300

47

30

20

20

RXS60F

50.9/42.4

46.3/42.4

49/46

49/46

(1) EER/COP according to Eurovent 2012 (2) The BYCQ140D7W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140D7W1W decoration panel in environments exposed to concentrations of dirt. (3) BYCQ140D7W1 = pure white panel with grey louvers , BYCQ140D7W1W = pure white standard panel with white louvers, BYCQ140D7GW1 = Pure white auto cleaning panel

FCQG35-60F BRC1E52A/B BRC7F532F RXS35K

Twin, triple, double twin application

› For long or irregularly shaped rooms you can use up to four indoor units powered by a single outdoor unit.

› All indoor units are controlled at the time.

FCQHG

71 50 60

FCQG

71

RZQG71L8V1 RZQG71L8Y1

RZQG100L8V1 RZQG100L8Y1

RZQG125L8V1 RZQG125L8Y1

RZQG140L7V1 RZQG140LY1

* Operation in heating mode down to -20°C

* 75m pipe run

* Compatibility with D-BACS

RZQ200C

RZQ250C

RZQSG71L3V1

RZQSG100L8V1 RZQSG100L8Y1

RZQSG125L8V1 RZQSG125L8Y1

RZQSG140LV1 RZQSG140LY1

* Operation in heating mode down to -15°C

* 100m pipe run

* Operation in heating mode down to -15°C

* 50m pipe run

* Compatibility with D-BACS

2

2

4

4

2

3

35

4

4

2

3

2

3

3

3

4

2

3 2

3

4

2

2

3

2

100 125

2

2

Multi model application

A single multi outdoor unit can power up nine indoor units in different rooms.

Of course, the climate of each room is individually controlled.

This assures top efficiency and optimum comfort for each seperate space

3MXS40K

3MXS52E

3MXS68G

4MXS68F

4MXS80E

5MXS90E

RXYSQ-P8V1

35

*

*

*

*

*

*

*

FCQG

50

*

*

*

*

*

*

60

*

*

*

*

*

Europe’s new energy label: raising the bar on energy efficiency

To realise its challenging 20-20-20 environmental goals, Europe is imposing minimum efficiency requirements for energy related projects. These minimum requirements came into effect on 1 January 2013, and will be revised upward in subsequent years.

Not only does the Eco-Design Directive systematically raise the minimum requirements with respect to environmental performance but the method used to measure this performance has also been changed to better reflect real-life conditions. The new seasonal performance rating provides a much more accurate picture of actual expected energy efficiency over an entire heating or cooling season.

Completing the picture is a new energy label for EU. The present label, introduced in

1992 and subsequently modified, allows consumers to compare and make purchasing decisions based on uniform labelling criteria. The new label includes multiple classifications from A+++ to D reflected in colour shadings ranging from dark green

(most energy efficient) to red (least efficient). Information on the new label includes not only the new seasonal efficiency ratings for heating (SCOP) and cooling (SEER), but also annual energy consumption and sound levels. It will allow end-users to make even better informed choices, since seasonal efficiency reflects air conditioner or heat pump efficiency over an entire season.

The present leaflet is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe

N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V.

Daikin Europe N.V. participates in the Eurovent

Certification programme for Air conditioners (AC),

Liquid Chilling Packages (LCP), Air handling units

(AHU) and Fan coil units (FCU), Check ongoing validity of certificate online: www.eurovent-certification.com or using: www.certiflash.com”

Daikin products are distributed by:

FSC

ECPEN13-110

Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende

Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement