Introduction
5
Index
10
11
About Us
Optical Fiber Cables
SLT SJ Fiber Optic Cable
14
SLT SJ SA Fiber Optic Cable
15
SLT DJ SA Fiber Optic Cable
16
MLT SJ Fiber Optic Cable
17
MLT SJ SA Fiber Optic Cable
18
MLT DJ SA Fiber Optic Cable
19
DJ DSA Fiber Optic Cable
20
DJ ADSS Fiber Optic Cable
21
DJ DSTA Fiber Optic Cable
22
DJ SWA Fiber Optic Cable
23
Underwater Fiber Optic Cable
24
Submarine Type SLT Fiber Optic Cable
25
Pigtail Cable
26
SX Zipcord Patch Cord Cable
27
DX Zipcord Patch Cord Cable
28
FTTx Drop Cable
29
Mini Breakout Cable
30
Breakout Cable
31
SX Round Armoured Cable
32
DX Round Armoured Cable
33
Telecommunication Copper Cables
JF Underground Copper Cable
37
JF Direct Burial Copper Cable
38
Dry Core Underground Copper Cable
39
Dry Core FIG-8 Copper Cable
40
Dry Core Indoor Copper Cable
41
Jumper Wire Cable
42
Drop Wire Copper Cable
43
index
Fiber Optic Patch Cord & Pigtails
46
ST Patch Cord & Pigtail Series
47
SC Patch Cord & Pigtail Series
48
FC Patch Cord & Pigtail Series
49
LC Patch Cord & Pigtail Series
50
MTRJ Patch Cord & Pigtail Series
51
E2000 Patch Cord & Pigtail Series
52
SMA 905 & MU Patch Cord & Pigtail Series
53
MPO Patch Cord & Pigtail Series
Fiber Optic Splice on Connectors
57
Swift SC Connectors
58
Swift LC Connectors
59
Swift FC Connectors
Fiber Optic Adapters
60
ST Adapter Series
61
SC Adapter Series
62
LC Adapter Series
63
FC Adapter Series
64
E2000/MU/MTRJ/MPO Adapter Series
65
Hybrid Adapter Series
66
Bare Adapter Series
67
Male To Female Adapter Series
Attenuator Series
ST/SC/LC/FC Attenuator Series
68
index
Fiber Optic Converters
69
10/100 M Fiber Ethernet Media Converter
70
10/100/1000 M Fiber Ethernet Media Converter
71
1000 M GB Fiber Ethernet Media Converter
Fiber Optic Patch Panels
1U 19” Rack Type Patch Panel
74
75
2U 19” Sliding Type Patch Panel
3U Termination Patch Panel
76
77
78
4U Termination Patch Panel
79
80
81
82
83
Wall Mounted Type Patch Panel
Note Page
Splitters
84
PLC Splitter
85
2xN Splitter
Fiber Optic Closures
Fiber Dome Closure Heat Shrink - L5
Fiber Dome Closure Heat Shrink - S4
86
87
Fiber Optic Fusion Splicers
Swift F3-FTTx Smallest Fusion Splicer
Swift F1-FTTx All in One Fusion Splicer
Swift S3 Core Aligment Fusion Splicer
Swift S5 Core Aligment All in One Fusion Splicer
Swift R1 Ribbon All in One Fusion Splicer
90
91
92
93
94
95
96
97
98
99
index
Fiber Optic Fusion Splicer Accessories
100
102
103
Swift Cleaver Types
Cleaver Blades And Electrodes
104
Fiber Holders
105
Note Page
Fiber Optic Test & Measurement Devices
108
109
JDSU MTS 2000
110
111
112
113
114
115
JDSU MTS 4000
JDSU MTS 6000
JDSU Power Meter
JDSU Light Source
116
Visual Fault Locators
117
Cable Certifier
118
Fiber Optic Identfier
119
Bare Fiber Optic OTDR Test Patch Cord
120
121
Launch Cable Box
Other Fiber Optic Products
Fiber Optic Hand Tools
124
Professional Tool Kit
125
Fiber Optic Cleaning Kit
126
127
Note Page
Data & Lan Cables
CAT 5E UTP Data Cables
CAT 5E FTP Data Cables
CAT 5E STP Data Cables
CAT 6 UTP Data Cables
CAT 6 FTP Data Cables
CAT 6 STP Data Cables
CAT 7 STP Data Cables
CAT 8 STP Data Cables
130
131
132
133
134
135
136
137
index
Data & Lan Patch Cord Cables
138
CAT 5E UTP/FTP/STP Patch Cord Cables
139
CAT 6E UTP/FTP/STP Patch Cord Cables
Data & Lan Accessories
140
141
142
143
144
Copper Patch Panels
Keystone Jacks
145
Plugs
Fiber Optic Cabins & Cabinets
148
Soho Wall Mount Cabinets
149
Wall Mount Cabinets
150
Free Standing Cabinets
151
Server Standing Cabinets
152
Cabinet Accessories
153
Note Page
Training
Content of Training
155
Certificates & Standards
Certificates
Note Page
Standards
Note Page
156
157
158
159
ABOUT US
“The New Era of Telecommunication”
The aim of the Erat Telekom which has been established in 1998 year is Fiber Optic
Infrastructure Implementation and production of Fiber Optic Accessories.
As Erat Telekom we would like;
To be a quality defining company in this field and fully satisfy our customers.
To be a company which is preferrable in the world due to its quality products ,
good services and customer delight. To improve its quality of products and services
in parallel with growing technology.
To provide quality products to our customers with suitable prices without quality decrease.
We started with “ The new era of telecommunication” slogan and we are proud of making
our brand one of the rising values of the market and sharing our quality and success
with our valued customers.
Fatih ERKAN
General Manager
WHY SHOULD YOU PURCHASE ERAT PRODUCTS?
Major benefits are listed below;
QUALITY: ERAT provides its main goal of customer delight with quality Management,
5S System and aimed the unconditional customer delight the SIX SIGMA Process. However; all connectors are tested with the method of sampling by max. and min. temperature operating range, Moisture Resistance,Vibration , Tension, Connection Strenght,
Geo metrical Measurement testes. Together with this foolproofing process, each materialof our products are compliance with universal fiber optic standarts; ANSI,
TIA/EIA-568-B.3, EIA-568/A, IEC 60874 and ISO 11801 criteria. In addition to this
certification, we have applied to TSE and ISO certifications of end product.
PRICE: Our investments for technology, expertise on our field and optimum cost policy
provide us to supply accurate pruducts to convenient customers.
TECHNOLOGY: Our full mechanical high technology patchcord and pigtail products are
tested by OTDR devices in our quality labs and they are delivered to customers after
checing with special 400X fiber microscopes. Due to all applied testes for measurement
range of insertion and return loss are compliance with the universal standarts, we provide the same high quality standarts for both domestic and foreing customers.
CAPACITY: Erat is up to produce high quantity orders and projected mass production
with the flexible prodution system according to customer demands.
SHIPMENT: After brought from laboratories, all products are packed by personells using
special protective. All packed products has its own test results in and polish pictures
rigth side of the barcode on the package.
“The new era of telecommunication”
www.erattelekom.com.tr
11
12
“The new era of telecommunication”
www.erattelekom.com.tr
OPTICAL FIBER CABLES
E
H
T
W
E
N
A
R
E
F
O
N
O
I
T
A
IC
N
U
M
M
O
C
E
L
E
T
ONLY
OPTICAL FIBER CABLES
“The new era of telecommunication”
www.erattelekom.com.tr
13
Single Loose Tube Single Jacket
Optical Fiber Cable
Optical Fiber Cable
A4
A1
A2
A3
A4
A3
A2
A1
Optical Fiber
Single Lose Tube(SLT)
Armouring Yarn
Outer Jacket
Applications
This type of optical cable is aimed to be used for voice, data, broadband and CATV transmission in Long
Distance, Backbone, Local Area, FTTx and Metro Networks with Indoor, Duct and Lashed Aerial installation
methods. Suitable for installation by Air Blowing. This type of cable is used as Drop Cable and intended
mainly for FTTx applications.
Features
Options
Single Loose Tube (SLT) Design
Reduced Cost
Light Weight Non-Metallic Design
Flexible Design and Easy Handling
Fast Cable Preparation and Installation
No Grounding Issues
Protection Against Water and Moisture
UV Stabilized LDPE or LLDPE or MDPE or
HDPE Jacket
Higher Fiber Capacities
Singlemode (Standard, Low Water Peak), Multimode
(50/125, 62.5/125), Non-Zero Dispersion Shifted
Hybrid (Composite) Cable Designs Metallic Central
Strength Member
Waterproof Dry Core Design
Design without Aluminum Tape Shielding Improved
Tensile Strength
Improved Compressive Strength
Low Smoke, Zero Halogen, Flame Retardant Jackets
Higher Span Length Designs
Bitumenized or Flooded Messenger Wire
SPECIFICATIONS
Fiber Count
No.of Tubes
No.of Fibers/Tube
Central Strength
Member
Core Filling
1-12
1(Central)
1-12
Not Applicable
Jelly Filled
Max.Tensile Load
Short / Long Term
Compressive
Strength
Min.Bending Radius
During / After Installation
Environmental Characteristics
Operation / Installation /
Storage
1000 N/500 N
1000 N /100 mm (min.)
ODx20/ODx10
-40 ... +70/-20 ... +60/40 ... +70 °C
Standards:
ITU-T Recommendations, IEC 60794, IEC 60332, IEC 304 or EIA/TIA-598
14
“The new era of telecommunication”
www.erattelekom.com.tr
Single Loose Tube Single Jacket
Steel Armoured Optical Fiber Cable
Optical Fiber Cable
A6
A5
A4
A1 Optical Fiber
A2 Tube Filling Compound
A3 Single Loose Tube (SLT)
A3
A2
A1
A4 Peripheral Strength Members
A5 Armoring Jacket
A6 Outer Jacket
Applications
This type of optical cable is aimed to be used for voice, data, broadband and CATV transmission in Long
Distance, Backbone, Local Area, FTTx and Metro Networks with Direct Burial, Duct and Lashed Aerial
installation methods. The optional single jacket design is used as Drop Cable and intended mainly for
FTTx applications.
Features
Options
Single Loose Tube (SLT) Design
Reduced Cost
Light Weight Armored Design
Corrugated Steel Tape Armored
Flexible Design and Easy Handling
Fast Cable Preparation and Installation
Improved Compressive Strength
Rodent Resistant
Protection Against Water and Moisture
Higher Fiber Capacities (upto 16 Fibers)
Singlemode (Standard, Low Water Peak), Multimode
(50/125, 62.5/125), Non-Zero Dispersion Shifted
Tight Buffered Fiber Design
Hybrid (Composite) Cable Designs
Improved Tensile Strength
Improved Compressive Strength
Low Smoke, Zero Halogen, Flame Retardant Jackets
Single Jacket Single Armor
SPECIFICATIONS
Fiber Count
No.of Tubes
No.of Fibers/Tube
Central Strength
Member
Core Filling
1-12
1(Central)
1-12
Not Applicable
Jelly Filled
Max.Tensile Load
Short / Long Term
Compressive
Strength
Min.Bending Radius
During / After Installation
Environmental Characteristics
Operation / Installation /
Storage
1500 N/750 N
2000 N /100 mm (min.)
ODx20/ODx10
-40 ... +70/-20 ... +60/40 ... +70 °C
Standards:
ITU-T Recommendations, IEC 60794, IEC 60332, IEC 304 or EIA/TIA-598
“The new era of telecommunication”
www.erattelekom.com.tr
15
Single Loose Tube Double Jacket
Steel Armoured Optical Fiber Cable
Optical Fiber Cable
A7
A1
A2
A3
A4
A6
A5
A4
A3
A2
A1
A5 Inner Jacket
A6 Armoring Jacket
A7 Outer Jacket
Optical Fiber
Tube Filing Compound
Single Loose Tube (SLT)
Peripheral Strength Members
Applications
This type of optical cable is aimed to be used for voice, data, broadband and CATV transmission in Long
Distance, Backbone, Local Area, FTTx and Metro Networks with Direct Burial, Duct and Lashed Aerial
istallation methods. The optional single jacket design is used as Drop Cable and intended mainly for FTTx
applications.
Features
Options
Single Loose Tube (SLT) Design
Reduced Cost
Light Weight Armored Design
Corrugated Steel Tape Armored
Flexible Design and Easy Handling
Fast Cable Preparation and Installation
Improved Compressive Strength
Rodent Resistant
Protection Against Water and Moisture
Higher Fiber Capacities (upto 16 Fibers)
Singlemode (Standard, Low Water Peak), Multimode
(50/125, 62.5/125), Non-Zero Dispersion Shifted
Tight Buffered Fiber Design
Hybrid (Composite) Cable Designs
Improved Tensile Strength
Improved Compressive Strength
Low Smoke, Zero Halogen, Flame Retardant Jackets
Single Jacket Single Armor
SPECIFICATIONS
Fiber Count
No.of Tubes
No.of Fibers/Tube
Central Strength
Member
Core Filling
1-12
1(Central)
1-12
Not Applicable
Jelly Filled
Max.Tensile Load
Short / Long Term
Compressive
Strength
Min.Bending Radius
During / After Installation
Environmental Characteristics
Operation / Installation /
Storage
1500 N/750 N
2000 N /100 mm (min.)
ODx20/ODx10
-40 ... +70/-20 ... +60/40 ... +70 °C
Standards:
ITU-T Recommendations, IEC 60794, IEC 60332, IEC 304 or EIA/TIA-598
16
“The new era of telecommunication”
www.erattelekom.com.tr
Multi Loose Tube Single Jacket
Optical Fiber Cable
A1
A2
A3
A4
A5
A4
A3
A2
Optical Fiber Cable
A5
A1
Central Strength Member
Optical Fiber
Single Loose Tube (SLT)
Peripheral Strength Members
Outer Jacket
Applications
This type of optical cable is aimed to be used for voice, data, broadband and CATV transmission in Long
Distance, Backbone, Local Area and Metro Networks with Duct and Lashed Aerial installation methods.
Suitable for installation by Air Blowing.
Features
Options
Multi Loose Tube (MLT) Design
Light Weight Non-Metallic Design
Flexible Design and Easy Handling
Fast Cable Preparation and Installation
No Grounding Issues
Protection Against Water and Moisture
UV Stabilized LDPE or LLDPE or MDPE or
HDPE Jacket
Higher Fiber Capacities
Singlemode (Standard, Low Water Peak), Multimode
(50/125, 62.5/125), Non-Zero Dispersion Shifted
Hybrid (Composite) Cable Designs
Metallic Central Strength Member
Waterproof Dry Core Design
Improved Tensile Strength
Rodent Resistant Design
Improved Compressive Strength
Low Smoke, Zero Halogen, Flame Retardant Jackets
SPECIFICATIONS
Fiber Count
No.of Tubes
No.of Fibers/Tube
Central Strength Member
Core Filling
2 - 144
1- 12
1-12
All Dielectric (FRP or GRP)
Jelly Filled
Max.Tensile Load
Short / Long Term
Compressive
Strength
Min.Bending Radius
During / After Installation
Environmental Characteristics
Operation / Installation /
Storage
2700 N/890 N
2000 N /100 mm (min.)
ODx20/ODx10
-40 ... +70/-20 ... +60/40 ... +70 °C
Standards:
ITU-T Recommendations, IEC 60794, IEC 60332, IEC 304 or EIA/TIA-598
“The new era of telecommunication”
www.erattelekom.com.tr
17
Multi Loose Tube Single Jacket
Steel Armoured Optical Fiber Cable
Optical Fiber Cable
A7
A1
A2
A3
A4
A6
Central Strength Member
Optical Fiber
Loose Buffer Tube
Core Wrapping (s)
A5
A4
A3
A2
A1
A5 Peripheral Strength Members
A6 Armouring Layers
A7 Outer Jacket
Applications
This type of optical cable is aimed to be used for voice, data, broadband and CATV transmission in Long
Distance, Backbone, Local Area and Metro Networks with Direct Burial, Duct and Lashed Aerial installation
methods. Suitable for installation by Air Blowing.
Features
Options
Multi Loose Tube (MLT) Design
Corrugated Steel Tape Armor
Improved Compressive Strength
Rodent Resistant
Protection Against Water and Moisture
UV Stabilized LDPE or LLDPE or MDPE or
HDPE Jacket
Higher Fiber Capacities
Singlemode (Standard, Low Water Peak), Multimode
(50/125, 62.5/125), Non-Zero Dispersion Shifted
Hybrid (Composite) Cable Designs Metallic Central
Strength Member
Waterproof Dry Core Design
Improved Tensile Strength
Improved Compressive Strength
Low Smoke, Zero Halogen, Flame Retardant Jackets
SPECIFICATIONS
Fiber Count
No.of Tubes
No.of Fibers/Tube
Central Strength Member
Core Filling
2 - 144
1 - 12
1-12
All Dielectric (FRP or GRP)
Jelly Filled
Max.Tensile Load
Short / Long Term
Compressive
Strength
Min.Bending Radius
During / After Installation
Environmental Characteristics
Operation / Installation /
Storage
2700 N/890 N
2000 N /100 mm (min.)
ODx20/ODx10
-40 ... +70/-20 ... +60/40 ... +70 °C
Standards:
ITU-T Recommendations, IEC 60794, IEC 60332, IEC 304 or EIA/TIA-598
18
“The new era of telecommunication”
www.erattelekom.com.tr
Multi Loose Tube Double Jacket
Single Armoured Optical Fiber Cable
Optical Fiber Cable
A8
A1
A2
A3
A4
A7
A6
Central Strength Member
Optical Fiber
Loose Buffer Tube
Core Wrapping (s)
A5
A6
A7
A8
A5
A4
A3
A2
A1
Peripheral Strength Members
Inner Jacket
Armouring Layers
Outer Jacket
Applications
This type of optical cable is aimed to be used for voice, data, broadband and CATV transmission in Long
Distance, Backbone, Local Area and Metro Networks with Direct Burial and Duct installation methods.
Features
Options
Multi Loose Tube (MLT) Design
Corrugated Steel Tape Armor
Improved Compressive Strength
Rodent Resistant
Protection Against Water and Moisture
UV Stabilized LDPE or LLDPE or MDPE or
HDPE Jacket
Higher Fiber Capacities
Singlemode (Standard, Low Water Peak), Multimode
(50/125, 62.5/125), Non-Zero Dispersion Shifted
Hybrid (Composite) Cable Designs
Metallic Central Strength Member
Waterproof Dry Core Design
Improved Tensile Strength
Improved Compressive Strength
Low Smoke, Zero Halogen, Flame Retardant Jackets
SPECIFICATIONS
Fiber Count
No.of Tubes
No.of Fibers/Tube
Central Strength Member
Core Filling
2 - 144
1- 12
1-12
All Dielectric (FRP or GRP)
Jelly Filled
Max.Tensile Load
Short / Long Term
Compressive
Strength
Min.Bending Radius
During / After Installation
Environmental Characteristics
Operation / Installation /
Storage
2700 N/890 N
4000 N /100 mm (min.)
ODx20/ODx10
-40 ... +70/-20 ... +60/40 ... +70 °C
Standards:
ITU-T Recommendations, IEC 60794, IEC 60332, IEC 304 or EIA/TIA-598
“The new era of telecommunication”
www.erattelekom.com.tr
19
Double Jacket Double Steel Armoured
Optical Fiber Cable
Optical Fiber Cable
A3
A2
B10
A1
B9
A1 Web
A2 Stranded Galvanized Steel Messenger
A3 PE Coating
B8
B1
B2
B3
B4
B5
B7
B6
B5
B4
Central Strength Member
Optical Fiber
Loose Buffer Tube
Core Warappings
Peripheral Strength Members
B3
B6
B7
B8
B9
B10
B2
B1
Aluminum Tape Shield
Inner Jacket
Bedding Layers
Armouring Layers
Outher Jacket
Applications
This type of optical cable is aimed to be used for voice, data, broadband and CATV transmission in Long
Distance, Backbone, Local Area and Metro Networks with Aerial installation method.
Features
Options
Multi Loose Tube (MLT) Design
Self Supporting Figure-8 Shape
Double Layer Galvanized Steel Tape Armor
Improved Compressive Strength
Rodent Resistant Aluminum Tape Shielded
Protection Against Water and Moisture
Maximum 80 meters of Span Length
UV Stabilized LDPE or LLDPE or MDPE or
HDPE Jacket
Higher Fiber Capacities
Singlemode (Standard, Low Water Peak), Multimode
(50/125, 62.5/125), Non-Zero Dispersion Shifted
Hybrid (Composite) Cable Designs Metallic Central
Strength Member
Waterproof Dry Core Design
Improved Tensile Strength
Improved Compressive Strength
Low Smoke, Zero Halogen, Flame Retardant Jackets
SPECIFICATIONS
Fiber Count
No.of Tubes
No.of Fibers/Tube
Central Strength Member
Core Filling
2 - 144
1 - 12
1-12
All Dielectric (FRP or GRP)
Jelly Filled
Max.Tensile Load
Short / Long Term
Compressive
Strength
Min.Bending Radius
During / After Installation
Environmental Characteristics
Operation / Installation /
Storage
5000 N/2700 N
4500 N /100 mm (min.)
ODx20/ODx10
-40 ... +70/-20 ... +60/40 ... +70 °C
Standards:
ITU-T Recommendations, IEC 60794, IEC 60332, IEC 304 or EIA/TIA-598
20
“The new era of telecommunication”
www.erattelekom.com.tr
Double Jacket All Dielectric Self Supporting
(ADSS) Optical Fiber Cable
Optical Fiber Cable
A7
A1
A2
A3
A4
A6
A5
A4
A3
A2
A1
A5 Inner Jacket
A6 Peripheral Strength Members
A7 Outer Jacket
Central Strength Member
Optical Fiber
Loose Buffer Tube
Core Wrappings
Applications
This type of optical cable is aimed to be used for voice, data, broadband and CATV transmission in Long
Distance,Backbone and Local Area Networks with Aerial installation method. Special design suitable for
installation on Power Transmission Lines and nearby Power Utilities.
Features
Options
Multi Loose Tube (MLT) Design
Non-Metallic Design
Flexible Design and Easy Handling
No Grounding Issues
High Tensile Strength
Improved Compressive Strength
Protection Against Water and Moisture
Designs for Different Span Lengths, Sag
and Weather Conditions
UV Stabilized LDPE or LLDPE or MDPE or
HDPE Jacket
Higher Fiber Capacities
Singlemode (Standard, Low Water Peak), Multimode
(50/125, 62.5/125), NonZero Dispersion Shifted
Hybrid (Composite) Cable Designs
Waterproof Dry Core Design
Tensile Strength according to NESC Light, Medium,
Heavy Conditions and
Different Span Lengths
Improved Compressive Strength
Single Jacket Design
Rodent Resistant
Tracking Resistant PE
SPECIFICATIONS
Fiber Count
No.of Tubes
No.of Fibers/Tube
Central Strength Member
Core Filling
2 - 144
1- 12
1-12
All Dielectric (FRP or GRP)
Jelly Filled
Max.Tensile Load
Short / Long Term
Compressive
Strength
Min.Bending Radius
During / After Installation
Environmental Characteristics
Operation / Installation /
Storage
According to NESC Conditions
3000 N /100 mm (min.)
ODx20/ODx10
-40 ... +70/-20 ... +60/40 ... +70
Standards:
ITU-T Recommendations, IEC 60794, IEC 60332, IEC 304 or EIA/TIA-598
“The new era of telecommunication”
www.erattelekom.com.tr
21
Double Jacket, Double Steel Tape
Armoured Optical Fiber Cable
Optical Fiber Cable
A1O
A1
A2
A3
A4
A5
A9
A3
A7
A6
A7
A8
A9
A10
Central Strength Member
Optical Fiber
Loose Buffer Tube
Core Wrapping (s)
Peripheral Strength Members
A6
A5
A4
A3
A2
A1
Aluminum Tape Shield
Inner Jacket
Bedding Layers
Armoring Layer
Outer Jacket
Applications
This type of optical cable is aimed to be used for voice, data, broadband and CATV transmission in Long
Distance,Backbone and Local Area Networks with Direct Burial and Duct installation methods
Features
Options
Multi Loose Tube (MLT) Design
Double Layer Galvanized Steel Tape Armor
Improved Compressive Strength
Rodent Resistant Aluminum Tape Shielded
Protection Against Water and Moisture
UV Stabilized LDPE or LLDPE or MDPE or
HDPE Jacket
Higher Fiber Capacities
Singlemode (Standard, Low Water Peak), Multimode
(50/125, 62.5/125), Non-Zero Dispersion Shifted
Hybrid (Composite) Cable Designs
Metallic Central Strength Member
Waterproof Dry Core Design
Design without Aluminum Tape Shield
Improved Tensile Strength
Improved Compressive Strength
Low Smoke, Zero Halogen, Flame Retardant Jackets
SPECIFICATIONS
Fiber Count
No.of Tubes
No.of Fibers/Tube
Central Strength Member
Core Filling
2 - 144
1 - 12
1-12
All Dielectric (FRP or GRP)
Jelly Filled
Max.Tensile Load
Short / Long Term
Compressive
Strength
Min.Bending Radius
During / After Installation
Environmental Characteristics
Operation / Installation /
Storage
2700 N/890 N
4500 N /100 mm (min.)
ODx20/ODx10
-40 ... +70/-20 ... +60/40 ... +70
Standards:
ITU-T Recommendations, IEC 60794, IEC 60332, IEC 304 or EIA/TIA-598
22
“The new era of telecommunication”
www.erattelekom.com.tr
Double Jacket, Steel Wire Armoured
Optical Fiber Cable
Optical Fiber Cable
A9
A1
A2
A3
A4
A5
A8
Central Strength Member
Optical Fiber
Loose Buffer Tube
Core Wrapping (s)
Peripheral Strength Members
A7
A6
A7
A8
A9
A6
A5
A4
A3
A2
A1
Aluminum Tape Shield
Inner Jacket
Armoring Layer
Outer Jacket
Applications
This type of optical cable is aimed to be used for voice, data, broadband and CATV transmission in Long
Distance and Backbone Networks with Direct Burial, Duct, Swamp and River Crossing installation
methods.
Features
Options
Multi Loose Tube (MLT) Design
Steel Wire Armor
Improved Compressive Strength
Rodent Resistant
Aluminum Tape Shielded
Protection Against Water and Moisture
UV Stabilized LDPE or LLDPE or MDPE
or HDPE Jackett
Higher Fiber Capacities
Singlemode (Standard, Low Water Peak), Multimode
(50/125, 62.5/125), Non-Zero Dispersion Shifted
Hybrid (Composite) Cable Designs
Metallic Central Strength Member Waterproof Dry
Core Design
Designs without Aluminum Tape Shielding
Improved Tensile Strength
Improved Compressive Strength
Low Smoke, Zero Halogen, Flame Retardant Jackets
SPECIFICATIONS
Fiber Count
No.of Tubes
No.of Fibers/Tube
Central Strength Member
Core Filling
2 - 144
1- 12
1-12
All Dielectric (FRP or GRP)
Jelly Filled
Max.Tensile Load
Short / Long Term
Compressive
Strength
Min.Bending Radius
During / After Installation
Environmental Characteristics
Operation / Installation /
Storage
7000 N/4000 N
5000 N /100 mm (min.)
ODx20/ODx10
-40 ... +70/-20 ... +60/40 ... +70
Standards:
ITU-T Recommendations, IEC 60794, IEC 60332, IEC 304 or EIA/TIA-598
“The new era of telecommunication”
www.erattelekom.com.tr
23
Underwater / River Crossing Type
Optical Fiber Cable
Optical Fiber Cable
A12
A1
A2
A3
A4
Central Strength Member
Dummy Element
Optical Fiber
Loose Buffer Tube
A11
A10
A5
A6
A7
A8
A9
A8
Core Wrapping (s)
Peripheral Strength Members
Armoring Tape Shield
Inner Jacket
A7
A9
A10
A11
A12
A6 A5 A4 A3 A2
A1
First Armoring Layer
Intermediate Jacket
Second Armoring Layer
Outer Jacket
Applications
This type of optical cable is aimed to be used for voice, data, broadband and CATV transmission in Long
Distance,Backbone and Local Area Networks with Underwater installation method for Swamp, Lake and
River Crossings.
Features
Options
Multi Loose Tube (MLT) Design
Double Layer Steel Wire Armor
Improved Compressive Strength
High Tensile Strength Aluminum Tape
Shielded
Protection Against Water and Moisture
UV Stabilized HDPE Jacket
Higher Fiber Capacities
Singlemode (Standard, Low Water Peak), Multimode
(50/125, 62.5/125), Non-Zero Dispersion Shifted
Hybrid (Composite) Cable Designs Metallic Central
Strength Member
Waterproof Dry Core Design
High Tensile Strength
Improved Compressive Strength
Double Jacket Single Armor Design
Bitumenized Poly Propylene Yarns as Outer Jacket
SPECIFICATIONS
Fiber Count
No.of Tubes
No.of Fibers/Tube
Central Strength Member
Core Filling
2 - 144
1 - 12
1-12
All Dielectric (FRP or GRP)
Jelly Filled
Max.Tensile Load
Short / Long Term
Compressive
Strength
Min.Bending Radius
During / After Installation
Environmental Characteristics
Operation / Installation /
Storage
20000 N/8000 N
7000 N /100 mm (min.)
ODx20/ODx10
-40 ... +70/-20 ... +60/40 ...
Standards:
ITU-T Recommendations, IEC 60794, IEC 60332, IEC 304 or EIA/TIA-598
24
“The new era of telecommunication”
www.erattelekom.com.tr
Submarine Type Single Loose Tube
Optical Fiber Cable
Optical Fiber Cable
A7
A1
A2
A3
A4
A6
Optical Fiber
Single Loose Tube (SLT)
Inner Jacket
Aluminum Tape Shield
A5
A4
A3
A2
A1
A5 Intermediate Jacket
A6 Armoring Layer
A7 Outer Jacket
Applications
This type of optical cable is aimed to be used for voice, data, broadband and CATV transmission in Long
Distance, Backbone and Local Area Networks with Underwater/Submarine installation method.
Features
Options
Single Loose Tube (SLT) Design
Light Weight Submarine Design
One Layer Steel Wire Armor
Improved Compressive Strength
High Tensile Strength Aluminum Tape
Shielded
Protection Against Water and Moisture
UV Stabilized HDPE Jacket
Higher Fiber Capacities (upto 16 Fibers)
Higher Fiber Capacities with Central Steel Tube (upto
48 Fibers)
Singlemode (Standard, Low Water Peak), Multimode
(50/125,62.5/125), Non-Zero Dispersion Shifted
Hybrid (Composite) Cable Designs
Improved Tensile Strength
Improved Compressive Strength
Central Steel Tube Design
Heavy Duty Double Armor Layer Design
Bitumenized Poly Propylene Yarns as Outer Jacket
SPECIFICATIONS
Fiber Count
No.of Tubes
No.of Fibers/Tube
Central Strength Member
Core Filling
1-12
1 (Central)
1-12
Not Applicable
Jelly Filled
Max.Tensile Load
Short / Long Term
Compressive
Strength
Min.Bending Radius
During / After Installation
Environmental Characteristics
Operation / Installation /
Storage
30000 N/10000 N
7000 N /100 mm (min.)
ODx20/ODx10
-40 ... +70/-20 ... +60/40 ... +70
Standards:
ITU-T Recommendations, IEC 60794, IEC 60332, IEC 304 or EIA/TIA-598
“The new era of telecommunication”
www.erattelekom.com.tr
25
Pigtail Cable
Pigtail Cables
B3
B2
B1
B1 Fiber
B2 Coating Layer
B3 Outer Jacket
Applications
Characteristics
Adopted to indoor distribution...
As pigtail of communication equipment.
Suitable for communication equipment served.
Can be installed conveniently and perated simply.
Soft. Easy to strip.
High quality tight buffered or Loose tube.
Excellent mechanical and environmental
performance.
Small cable volume. Ling weight
TECHNICAL PARAMETERS
Cable Count
1
Out sheath
Diameter
Minimum allowable TenWeight
sile Strength
(N)
Minimum allowable Crush
Load(00mm)
(N/100mm)
Minimum
Bending
Radius
(MM)
Storage
temperature
(MM)
(KG)
short
term
long
term
short
term
long
term
short
term
long
term
(℃)
0.9+/-0.05
0.90
100
50
100
80
20 D
10 D
-20+60
OPTICAL CHARACTERISTICS
Multi Mode
Fiber Sort
Single Mode
G.651
A1a:50/125
A1b:62.5/125
G.652(A,B,C)
B1.1:Conventional fiber
G.652D
B1.1:Conventional fiber
G.655
B1.2 :Cut-off wavelength shifted
G.657 (A1,A2,B3)
Standards:
IEC 60332-1, 60754-93-94 ANSI / TIA Specification
26
“The new era of telecommunication”
www.erattelekom.com.tr
Graded-index fiber
B4: Main technical data for positive
dispersion shifted single-mode fiber
Simplex Zipcord
Patch Cord Cable
B3
B1 Fiber
B2 Tight Buffer
B3
B4
B2
Patch Cord Cables
B4
B1
Kevler Yarn
Outer Jacket
Applications
Characteristics
Adopted to indoor distribution..
As pigtail of communication equipment.
Suitable for communication equipment served.
Can be installed conveniently and perated simply.
High strength kevlar yarn member.
High quality tight buffered or loose tube.
Soft and easy to strip.
Round construction.
TECHNICAL PARAMETERS
Out JacketDiameter
Minimum allowable TenTight buffer Weight
sile Strength
(N)
Minimum allowable Crush
Load(00mm)
(N/100mm)
Minimum
Bending
Radius
(MM)
Storage
temperature
(MM)
(MM)
(KG)
short
term
long
term
short
term
long
term
short
term
long
term
(℃)
1.6
0.6
2.80
150
80
500
100
20 D
10 D
-20+60
1.8
0.6
3.00
150
80
500
100
20 D
10 D
-20+60
2.0
0.9
4.25
150
80
500
100
20 D
10 D
-20+60
3.0
0.9
7.00
150
80
500
100
20 D
10 D
-20+60
OPTICAL CHARACTERISTICS
Multi Mode
Fiber Sort
Single Mode
G.651
A1a:50/125
A1b:62.5/125
Graded-index fiber
G.652(A,B,C)
B1.1:Conventional fiber
G.652D
B1.1:Conventional fiber
G.655
G.657 (A1,A2,B3)
B1.2 :Cut-off wavelength shifted
B4: Main technical data for positive
dispersion shifted single-mode fiber
Standards:
IEC 60332-1, 60754-93-94 ANSI / TIA Specification
“The new era of telecommunication”
www.erattelekom.com.tr
27
Duplex Zipcord
Patch Cord Cable
Patch Cord Cables
B3
B4
B1 Fiber
B2 Tight Buffer
B3
B4
B2
B1
Kevler Yarn
Outer Jacket
Applications
Characteristics
Adopted to indoor distribution...
As pigtail of communication equipment.
Suitable for communication equipment served.
Can be installed conveniently and perated simply
High strength kevlar yarn member.
High quality tight buffered or loose tube.
Soft and easy to strip.
Round constructionn.
TECHNICAL PARAMETERS
Out JacketDiameter
Minimum allowable TenTight buffer Weight
sile Strength
(N)
Minimum allowable Crush
Load(00mm)
(N/100mm)
Minimum
Bending
Radius
(MM)
Storage
temperature
(MM)
(MM)
(KG)
short
term
long
term
short
term
long
term
short
term
long
term
(℃)
1.6×3.4
0.6
4.80
150
80
500
100
20 D
10 D
-20+60
1.8×3.8
0.6
500
150
80
500
100
20 D
10 D
-20+60
2.0×4.2
0.9
7.00
150
80
500
100
20 D
10 D
-20+60
3.0×6.2
0.9
12.50
150
80
500
100
20 D
10 D
-20+60
OPTICAL CHARACTERISTICS
Multi Mode
Fiber Sort
Single Mode
G.651
A1a:50/125
A1b:62.5/125
G.652(A,B,C)
B1.1:Conventional fiber
G.652D
B1.1:Conventional fiber
G.655
B1.2 :Cut-off wavelength shifted
G.657 (A1,A2,B3)
Standards:
IEC 60332-1, 60754-93-94 ANSI / TIA Specification
28
“The new era of telecommunication”
www.erattelekom.com.tr
Graded-index fiber
B4: Main technical data for positive
dispersion shifted single-mode fiber
FTTx Drop Cable
FTTx Drop Cable
A2
A3
A1
A1 Fiber
A2 FPR Steel Convered By Copper
A3 LSZH Jacket
Characteristics
Applications
Adopted to indoor and outdoor distribution..
Suitable for FTTH and FTTB.
Fiber-to-the-home broadband connections
promise the next generation in connectivity
to consumers.
TECHNICAL PARAMETERS
Cable Count
1
Out Jacket
Diameter
Minimum allowable TenWeight
sile Strength
(N)
Minimum allowable Crush
Load(00mm)
(N/100mm)
Minimum
Bending
Radius
(MM)
Storage
temperature
(MM)
(KG)
short
term
long
term
short
term
long
term
short
term
long
term
(℃)
3.1*2.0
8
600
200
1000
300
20 D
10 D
40
OPTICAL CHARACTERISTICS
Multi Mode
Fiber Sort
Single Mode
G.651
A1a:50/125
A1b:62.5/125
Graded-index fiber
G.652(A,B,C)
B1.1:Conventional fiber
G.652D
B2: Zero dispersion shiftedV
G.655
B1.2 :Cut-off wavelength shifted
G.657 (A1,A2,B3)
B4: Main technical data for positive
dispersion shifted single-mode fiber
Standards:
IEC 60332-1, 60754-93-94 ANSI / TIA Specification
“The new era of telecommunication”
www.erattelekom.com.tr
29
Mini Breakout Cable
Mini Breakout
A4
A1
A2
A3
A4
A3
A2
A1
Fiber
Tight Buffer
Kevler Yarn
Outer Jacket
TECHNICAL PARAMETERS
Standardisation
DIN VDE 0888,
Part 6 and IEC 60
794-2
Application
Construc- Thermal
tion
properties
(Ideal for workstaTight
tion cabling due
buered
to the high flexber (TB),
ibility and small
semi-tight
dimensions.
buered
Non-metallic
ber (STB) or
indoor cable for
superstrip
direct connector
(LB)
assembly.
Mechanical
properties
Transport and storage–25°C to +70°C
max. pull force
max. crush resistance
long-term 800 N
long-term 300 N/dm
Fire
performance
Flame
retardancy
IEC 603321-2 and IEC
60332-322 Cat. A
TECHNICAL PARAMETERS
Number
of fibers
Outer Ø
(mm)
Min. bending
Weight (kg/
radius
km)
static (mm)
Min. bending
radius
dynamic (mm)
Min. bending
radius
dynamic (mm)
Fire load
(MJ/m)
2
6.0
35
60
85
600
800
0.63
4
6.0
35
60
85
600
800
0.63
6
6.9
47
70
105
800
800
0.89
8
8.3
69
85
125
800
800
1.22
10
9.9
105
100
150
800
800
2.01
12
11.0
119
110
165
800
800
2.37
16
10.7
106
110
160
1000
800
2.03
18
11.3
116
115
170
1000
800
2.27
Standards:
IEC 60332-1, 60754-93-94 ANSI / TIA Specification
30
Min. bending
radius
dynamic (mm)
“The new era of telecommunication”
www.erattelekom.com.tr
Breakout Cable
Breakout Cable
A6
A5
A1 Fiber
A2 Tight Buffer
A3 Kevler Yarn
A4
A3 A2
A1
A4 Indoor Jacket
A5 Kevler Yarn
A6 Outer Jacket
TECHNICAL PARAMETERS
Standardisation
DIN VDE 0888,
Part 6 and IEC 60
794-2
Construc- Thermal
tion
properties
Application
(Ideal for workstaTight
tion cabling due
buered
to the high flexber (TB),
ibility and small
semi-tight
dimensions.
buered
Non-metallic
ber (STB) or
indoor cable for
superstrip
direct connector
(LB)
assembly.
Transport and storage–25°C to +70°C
Fire
performance
Mechanical
properties
max. pull force
max. crush resistance
long-term 800 N
long-term 300 N/dm
Flame
retardancy
IEC 603321-2 and IEC
60332-322 Cat. A
TECHNICAL PARAMETERS
Number
of fibers
Outer Ø (mm)
Weight
(kg/km)
Min. bending radius
static (mm)
Min. bending radius
dynamic (mm)
Fire load
(MJ/m)
2
4.2
14
40
65
0.45
4
5.6
21
55
85
0.47
6
5.9
25
60
90
0.50
8
6.1
30
60
90
0.52
12
7.0
38
70
95
0.55
Standards:
IEC 60332-1, 60754-93-94 ANSI / TIA Specification
“The new era of telecommunication”
www.erattelekom.com.tr
31
Simplex Round Armoured Cable
Simplex Round Armoured Cable
32
“The new era of telecommunication”
www.erattelekom.com.tr
Dublex Round Armoured Cable
Dublex Round Armoured Cable
A1
A2
A3
A4
A5
Fiber
Tight Buffer
Stainless Steel
Kevlar Yarn
Outer Jacket
250k
g
12kg
TECHNICAL PARAMETERS
Cable Diameter
a
mm
Stainless steel tube diameter
b
mm
Tight-buffered fiber
diameter
mm
Φ1.8±0.1
Φ0.9±0.03
Φ0.4
Φ2.0±0.1
Φ1.0±0.05
Φ0.6
Φ2.4±0.1
Φ1.2±0.05
Φ0.6
Φ2.8±0.1
Φ1.2±0.05
Φ0.6
Φ3.0±0.1
Φ1.2±0.05
Φ0.6
Cable Diameter
(mm)
Tensile N
Short time Long time
Bend radius (mm)*
dynamic
static
Crush
N/100mm
Φ1 8±0 1
Φ1.8±0.1
160
8
80
50
30
5000
Φ2.0±0.1
200
100
50
30
4500
Φ2.4±0.1
250
130
50
30
4500
Φ2.8±0.1
500
250
60
30
3500
Φ3.0±0.1
600
300
60
30
3500
All the values which are for reference only
y.
Using fiber of G657 series , the bending radius will be less than 15mm.
“The new era of telecommunication”
www.erattelekom.com.tr
33
34
“The new era of telecommunication”
www.erattelekom.com.tr
TELECOMMUNICATION COPPER CABLES
E
H
T
W
E
N
A
R
E
F
O
N
O
I
T
A
IC
N
U
M
M
O
C
E
L
E
T
ONLY
TELECOMMUNICATION COPPER CABLES
“The new era of telecommunication”
www.erattelekom.com.tr
35
36
“The new era of telecommunication”
www.erattelekom.com.tr
Jelly Filled Underground
Copper Cable
A1
A2
A3
A4
A5
A4
A3
A2
A1
Solid Copper Conductor
Conductor Insulation
Core Wrappings(s)
Aluminum Tape Shield
Outer Jacket
Telecommmunication Copper Cables
A5
Applications
This type of copper telecommunication cable is aimed to be used in Long Distance, Backbone and
DistributionNetworks with Duct, Direct Burial and Lashed Aerial installation methods. For aerial
applications, the cable must be attached to a support messenger.
Features
Options
Solid Annealed Bare Copper Conductor
Jelly Filled Core
Aluminum Tape Shielded
Protection Against Water and Moisture
Single Jacket
Dry Core Design
Design with Corrugated Aluminum Shield
Mutual Capacitiance Value may vary as per Customer
Specification LDPE, LLDPE, MDPE, HDPE Jackets
Specification
Electrical Characteristics
Capacity : 10 Pairs Upto 2400 Pairs
Conductor Dia. : 0.4, 0.5, 0.6, 0.8, 0.9 mm
(26, 24, 22, 19 AWG)
Insulation Type : Foam-Skin or Solid
Twisting Method : Pair or Quad
Basic Units : 10 Pairs / 25 Pairs / 5 Quads
Outer Jacket : Black PE
Conductor Resistance : 144 Ohm / km 0.4 mm
89.5 Ohm/km 0.5 mm
63 Ohm/km 0.6 mm
35.5 Ohm/km 0.8 mm
28 Ohm/km 0.9 mm
Mutual Capacitance : 45, 50, 52, 55 nF/km or as per
Customer Specification
Insulation Resistance : 1600 MOhm.km
Standards:
IEC 708 - (1-4), ANSI / ICEA specification
“The new era of telecommunication”
www.erattelekom.com.tr
37
Jelly Filled Direct Burial
Copper Cable
Telecommmunication Copper Cables
A5
A1
A2
A3
A4
A5
A4
A3
A2
A1
Solid Copper Conductor
Conductor Insulation
Core Wrappings(s)
Aluminum Tape Shield
Outer Jacket
Applications
This type of copper telecommunication cable is aimed to be used in Long Distance, Backbone and Distribution Networks with Duct, Direct Burial and Lashed Aerial installation methods. For aerial applications, the
cable must be attached to a support messenger.
Features
Options
Solid Annealed Bare Copper Conductor
Dry Core Aluminum Tape Shielded
Protection Against Moisture
Single Jacket
Jelly Filled Core Design
Design with Corrugated Aluminum Shield
Mutual Capacitance Value may vary as per Customer
Specification
LDPE, LLDPE, MDPE, HDPE Jackets
Specification
Capacity : 10 Pairs Upto 2400 Pairs
Conductor Dia. : 0.4, 0.5, 0.6, 0.8, 0.9
mm (26, 24, 22, 19 AWG)
Insulation Type : Foam-Skin or Solid
Twisting Method : Pair or Quad
Basic Units : 10 Pairs / 25 Pairs / 5
Quads
Outer Jacket : Black PE
Standards:
IEC 708 - (1-4), ANSI / ICEA specification
38
“The new era of telecommunication”
www.erattelekom.com.tr
Electrical Characteristics
Conductor Resistance: 144 Ohm / km 0.4 mm
89.5 Ohm/km 0.5 mm
63 Ohm/km 0.6 mm
35.5 Ohm/km 0.8 mm
28 Ohm/km 0.9 mm
Mutual Capacitance : 45, 50, 52, 55 nF/km or as
per Customer Specification
Insulation Resistance :1600 MOhm.km
Dry Core Underground
Copper Cable
A1
A2
A3
A4
Solid Copper Conductor
Conductor Insulation
Core Wrappings(s)
Aluminum Tape Shield
A6
A5
A4
A3
A2
A1
A5 Inner Jacket
A6 Aluminum Layers
A7 Outer Jacket
Telecommmunication Copper Cables
A7
Applications
This type of copper telecommunication cable is aimed to be used in Long Distance, Backbone and Distribution Networks with Direct Burial installation method.
Features
Options
Solid Annealed Bare Copper Conductor
Jelly Filled Core Aluminum Tape Shielded
Protection Against Water and Moisture
Double Layer Galvanized Steel Tape Armor
Rodent Resistant
Double Jacket
Design with Corrugated Aluminum Shield
Corrugated Steel Tape Armor Design
Steel Wire Armor Design (special design for water
crossing purpose)
Mutual Capacitance Value may vary as per Customer
Specification LDPE, LLDPE, MDPE, HDPE Jackets
Specification
Electrical Characteristics
Capacity : 10 Pairs Upto 600 Pairs
Conductor Dia. : 0.4, 0.5, 0.6, 0.8, 0.9 mm
(26, 24, 22, 19 AWG)
Insulation Type : Foam-Skin or Solid
Twisting Method : Pair or Quad
Basic Units : 10 Pairs / 25 Pairs / 5 Quads
Outer Jacket : Black PE
Conductor Resistance : 144 Ohm / km 0.4 mm
89.5 Ohm/km 0.5 mm
63 Ohm/km 0.6 mm
35.5 Ohm/km 0.8 mm
28 Ohm/km 0.9 mm
Mutual Capacitance : 45, 50, 52, 55 nF/km or as per
Customer Specification
Insulation Resistance : 1600 MOhm.km
Standards:
IEC 708 - (1-4), ANSI / ICEA specification
“The new era of telecommunication”
www.erattelekom.com.tr
39
Dry Core Figure-8
Copper Cable
Telecommmunication Copper Cables
A3
B5
A2
A1
B4
B3
B2
B1
A1 Messenger Stranded Galvanized Steel B1 Solid Copper Conductor
A2 Web
B2 Conductor Insulation
A3 PE Coating
B3 Core Wrapping (S)
B4 Aluminum Tape Shield
B5 Outer Jacket
Applications
This type of copper telecommunication cable is aimed to be used in Long Distance, Backbone, Distribution
Networks and Subscriber Extensions with Aerial installation method.
Features
Options
Solid Annealed Bare Copper Conductor
Dry Core Aluminum Tape Shielded
Protection Against Moisture
Single Jacket
Stranded Galvanized Steel Messenger
Jelly Filled Core Design
Design without Aluminum Tape Shielding
Design with Corrugated Aluminum Shield
Mutual Capacitance Value may vary as per Customer
Specification
LDPE, LLDPE, MDPE, HDPE Jackets
Specification
Electrical Characteristics
Capacity : 2 Pairs Upto 400 Pairs
Conductor Dia. : 0.4, 0.5, 0.6, 0.8, 0.9
mm (26, 24, 22, 19 AWG)
Insulation Type : Foam-Skin or Solid
Twisting Method : Pair or Quad
Basic Units : 10 Pairs / 25 Pairs / 5
Quads
Outer Jacket : Black PE
Conductor Resistance: 144 Ohm / km 0.4 mm
89.5 Ohm/km 0.5 mm
63 Ohm/km 0.6 mm
35.5 Ohm/km 0.8 mm
28 Ohm/km 0.9 mm
Mutual Capacitance : 45, 50, 52, 55 nF/km or as
per Customer Specification
Insulation Resistance :1600 MOhm.km
Standards:
IEC 708 - (1-4), ANSI / ICEA specification
40
“The new era of telecommunication”
www.erattelekom.com.tr
Dry Core Indoor
Copper Cable
A1
A2
A3
A4
A3
A2
A1
Solid Copper Conductor
Conductor Insulation
Core Wrappings(s)
Outer Jacket
Telecommmunication Copper Cables
A4
Applications
This type of copper telecommunication cable is aimed to be used for Indoor and Local Area Network applications.
Features
Options
Solid Annealed Bare Copper Conductor
Dry Core
Flame Retardant Jacket
Tinned Copper Conductor
Tinned Copper Drain Wire Conductor
PE (Foam-skin or Solid) Insulation
Aluminum Tape Shielded
Mutual Capacitance Value may vary as per Customer
Specification
Halogen Free Flame Retardant (HFFR) Jacket
Specification
Electrical Characteristics
Capacity : 10 Pairs Upto 200 Pairs
Conductor Dia. : 0.4, 0.5, 0.6 mm (26, 24,
22 AWG)
Insulation Type : PVC
Twisting Method : Pair or Quad
Basic Units : 10 Pairs / 25 Pairs / 5 Quads
Outer Jacket : PVC
Conductor Resistance: 144 Ohm / km 0.4 mm
89.5 Ohm/km 0.5 mm
63 Ohm/km 0.6 mm
Mutual Capacitance : 90 nF/km
Insulation Resistance : 200 MOhm.km
Standards:
IEC 708 - (1-4), IEC 60332, ANSI / ICEA Specification
“The new era of telecommunication”
www.erattelekom.com.tr
41
Jumper Wire
Telecommmunication Copper Cables
A3
A2
A1
A1 Hard Drawn Copper Conductor
A2 Web
A3 Jacket
Applications
This type of copper telecommunication wire is aimed to be used for extension to subscriber premises.
Features
Options
Hard Drawn Copper Conductor
One Raised Ridge Tracer to Identify the
Polarity
Black PE Jacketed
Copper Cladded Steel Wire Conductor
Halogen Free Flame Retardant (HFFR) Insulation
Steel Support Messenger for Aerial Applications
Specification
Electrical Characteristics
Conductor Dia.: 0.8, 0.9, 1.0, 1.2 mm
(18.5, 19
AWG)
Insulation Type : HDPE
Coil Length : 500 ± 100 m
Conductor Resistance : 36.78 Ohm/km 0.8 mm
28.96 Ohm/km 0.9 mm
23.39 Ohm/km 1.0 mm
Insulation Resistance : 10000 MOhm.km
Standards:
IEC 708 - (1-4), IEC 60332, ANSI / ICEA Specification
42
“The new era of telecommunication”
www.erattelekom.com.tr
Drop Wire Copper Cable
B1
B1 Solid Copper Conductor
B2 Conductor Insulation
Telecommmunication Copper Cables
B2
Applications
This type of copper telecommunication wire is aimed to be used for cross-connections in telephone switch,
cabinets and subscriber’s premises.
Features
Options
Solid Annealed Copper Conductor
Semi Rigid Polyvinyl Chloride (PVC) Insulated
Each Conductor is Colored for Identification
Twisted to Form a Pair
Solid Tinned Copper Wire Conductor
Halogen Free Flame Retardant (HFFR)
Insulation
0.8 and 0.9 mm Conductor Diameter
Specification
Electrical Characteristics
Conductor Dia. : 0.5, 0.6 mm (24, 22 AWG)
Insulation Type : PVC
Coil Length : 500 ± 100 m
Conductor Resistance: 36.78 Ohm/km 0.5 mm
66 Ohm/km 0.6 mm
Insulation Resistance : 200 MOhm.km
Standards:
IEC 60332-1, 60754-93-94 ANSI / TIA Specification
“The new era of telecommunication”
www.erattelekom.com.tr
43
44
“The new era of telecommunication”
www.erattelekom.com.tr
FIBER OPTIC PATCH CORD CABLES
E
H
T
W
E
N
A
R
E
F
O
N
O
I
T
A
IC
N
U
M
M
O
C
E
L
E
T
ONLY
FIBER OPTIC PATCH CORD CABLES
“The new era of telecommunication”
www.erattelekom.com.tr
45
ST Patch Cord & Pigtail Series
Patch Cords & Pigtails
1
2
ST SM (UPC)
ST MM (PC)
Features
Ordering Choice
High return loss
Low insertion loss
Telcordia style boots
Compliance with TIA/IEA,IEC,Rohs
Fan-out patch cord
Simplex / Duplex Pigtail
12 color Cable
Loose & Tight Buffer
Boot Color
Cable Size 0.9mm, .8mm,
2.0mm, 2.4mm,3.0mm
Applications
Packing Style
Label Style
Plastic & Metal Body
MM, OM1,OM2,OM3,OM4
OFNR & LSZH & OFNP
SM G652D, G655, G657 A1/A2/B3
CATV, Metro,LANs,
Active device termination
Telecommunication networks
Industrial,medical & military
PARAMETERS
Item
Insertion Loss
Return Loss
46
Model Type
PC
UPC
APC
SM
≤0.25dB
≤0.20dB
≤0.15dB
MM
≤0.30dB
≤0.20dB
≤0.30dB
SM
≥45dB
≥55dB
≥65dB
MM
≥35dB
≥35dB
≥35dB
Operating Temperature
–40 C to +75 C
Durability
≤0.1dB ≤0.2 dB typical change , 500 matings
Available Wavelengths
MM - ƛ=850-1300 nm, SM - ƛ= 1310 & 1550 nm
Cable Diameter Options
0.9mm, 2.0mm, 3.0mm, others
“The new era of telecommunication”
www.erattelekom.com.tr
SC Patch Cord & Pigtail Series
2
SC SM (UPC)
3
SC SM (APC)
SC MM (PC)
Features
Ordering Choice
High return loss
Low insertion loss
Telcordia style boots
Compliance with TIA/IEA,IEC,Rohs
Fan-out patch cord
Simplex / Duplex Pigtail
12 color Cable
Loose & Tight Buffer
Boot Color
Cable Size 0.9mm, .8mm,
2.0mm, 2.4mm,3.0mm
Applications
Patch Cords & Pigtails
1
Packing Style
Label Style
Plastic & Metal Body
MM, OM1,OM2,OM3,OM4
OFNR & LSZH & OFNP
SM G652D, G655, G657 A1/A2/B3
CATV, Metro,LANs,
Active device termination
Telecommunication networks
Industrial,medical & military
PARAMETERS
Item
Insertion Loss
Return Loss
Model Type
PC
UPC
APC
SM
≤0.25dB
≤0.20dB
≤0.15dB
MM
≤0.30dB
≤0.20dB
≤0.30dB
SM
≥45dB
≥55dB
≥65dB
MM
≥35dB
≥35dB
≥35dB
Operating Temperature
–40 C to +75 C
Durability
≤0.1dB ≤0.2 dB typical change , 500 matings
Available Wavelengths
MM - ƛ=850-1300 nm, SM - ƛ= 1310 & 1550 nm
Cable Diameter Options
0.9mm, 2.0mm, 3.0mm, others
“The new era of telecommunication”
www.erattelekom.com.tr
47
FC Patch Cord & Pigtail Series
Patch Cords & Pigtails
1
2
FC SM (UPC)
3
FC SM (APC)
FC MM (PC)
Features
Ordering Choice
High return loss
Low insertion loss
Telcordia style boots
Compliance with TIA/IEA,IEC,Rohs
Fan-out patch cord
Simplex / Duplex Pigtail
12 color Cable
Loose & Tight Buffer
Boot Color
Cable Size 0.9mm, 1.8mm,
2.0mm, 2.4mm,3.0mm
Applications
Packing Style
Label Style
Plastic & Metal Body
OM1,OM2,OM3,OM4
OFNR & LSZH & OFNP
Key Ring
Tunable & Fixed
CATV, Metro,LANs,
Active device termination
Telecommunication networks
Industrial,medical & military
PARAMETERS
Item
Insertion Loss
Return Loss
48
Model Type
PC
UPC
APC
SM
≤0.3dB
≤0.3dB
≤0.3dB
MM
≤0.2dB
≤0.2dB
≤0.2dB
SM
≥20dB
≥50dB
≥60dB
MM
≥20dB
≥55dB
≥65dB
Operating Temperature
–40 C to +75 C
Durability
≤0.1 dB typical change , 500 matings
Available Wavelengths
SM =1310 & 1550nm, MM =850nm
Cable Diameter Options
0.9mm, 2.0mm, 3.0mm, others
“The new era of telecommunication”
www.erattelekom.com.tr
LC Patch Cord & Pigtail Series
2
LC SM (UPC)
3
LC SM (APC)
LC MM (PC)
Features
Ordering Choice
High return loss
Low insertion loss
Telcordia style boots
Compliance with TIA/IEA,IEC,Rohs
Fan-out patch cord
Simplex / Duplex Pigtail
12 color Cable
Loose & Tight Buffer
Boot Color
Cable Size0.9mm,1.8mm
,2.0mm,3.0mm
Applications
Patch Cords & Pigtails
1
Packing Style
Label Style
G652D, G657
MM, OM1,OM2,OM3,OM4
OFNR & LSZH & OFNP
LC Special Boot
Angle Boot
CATV, LANs,Telecom,Video
Active device termination
Telecommunication networks
Gigbit applications ( ATM, Ethernet)
PARAMETERS
Item
Insertion Loss
Return Loss
Model Type
PC
UPC
APC
SM
≤0.3dB
≤0.3dB
≤0.3dB
MM
≤0.2dB
≤0.2dB
≤0.2dB
SM
≥20dB
≥50dB
≥60dB
MM
≥20dB
≥55dB
≥65dB
Operating Temperature
–40 C to +75 C
Durability
≤0.2 dB typical change , 500 matings
Available Wavelengths
SM = 1310 & 1550 nm , MM =85nm
Cable Diameter Options
0.9mm, 2.0mm, 3.0mm, others
“The new era of telecommunication”
www.erattelekom.com.tr
49
MTRJ/PC Patch Cord Series
Patch Cords & Pigtails
1
2
MTRJ SM (PC)
MTRJ MM (PC)
Features
Ordering Choice
High return loss
Low insertion loss
Plug - jack,RJ - 45 Style
TIA/EIA 568 -A compliant
Fan-out patch cord
Simplex / Duplex Pigtail
12 color Cable
Loose & Tight Buffer
Boot Color
Cable Size
0.9mm,1.8mm,2.0mm,
Packing Style
Label Style
G652D, G657
OM1,OM2,OM3,OM4
OFNR & LSZH & OFNP
Metal & Female Type
Applications
CATV,LANs,Telecom,Video
Active device termination
Telecommunication networks
Gigbit Applications (ATM,Ethernet)
PARAMETERS
Item
Insertion Loss
Return Loss
50
Model Type
PC
SM
≤0.3dB
MM
≤0.2dB
SM
≥50dB
MM
≥20dB
Operating Temperature
–40 C to +75 C
Durability
≤0.1 dB typical change , 500 matings
Available Wavelengths
SM=1310 & 1550nm, MM =850nm
Cable Diameter Options
0.9mm, 2.0mm, 3.0mm, others
“The new era of telecommunication”
www.erattelekom.com.tr
E2000 Patch Cord & Pigtail Series
2
E2000 / APC
Features
Ordering Choice
High return loss
Low insertion loss
Telcordia style boots
Compliance with TIA/
IEA,IEC,Rohs
Fan - out patch cord
Simplex / Duplex Pigtail
12 color Cable
Loose & Tight Buffer
Boot Color
Cable Size
0.9mm,1.8mm,
2.0mm,3.0mm
Packing Style
Label Style
Angle =8deg.
G652D, G657
OM1,OM2,OM3,OM4
OFNR & LSZH & OFNP
Applications
CATV,Metro, LANs,
Active device
termination
Telecommunication
networks
Gigbit applications
(ATM,Ethernet)
Patch Cord Series
1
E2000 / PC
Features
High return loss
Low insertion loss
Telcordia style boots
Compliance with TIA/IEA,IEC,Rohs
Applications
CATV, LANs,Telecom,Video
Active device termination
Telecommunication networks
Gigbit Applications ( ATM, Ethernet)
PARAMETERS
Item
Insertion Loss
Return Loss
Model Type
PC
SM
≤0.3dB
MM
≤0.3dB
SM
≥20dB
MM
≥20dB
Operating Temperature
–40 C to +75 C
Durability
≤0.2 dB typical change , 500 matings
Available Wavelengths
SM = 1310 & 1550 nm , MM = 850nm
Cable Diameter Options
0.9mm, 2.0mm, 3.0mm, others
“The new era of telecommunication”
www.erattelekom.com.tr
51
SMA 905 & MU Patch Cord
Patch Cord Series
1
2
SMA 905
MU (PC)
Features
Ordering Choice
Simple termination
TIA / IEC compliant
Threaded nut connector
One piece construction
Fan-out patch cord
Simplex / Duplex Pigtail
12 color Cable
Loose & Tight Buffer
Boot Color
Cable Size 0.9mm, 1.8mm, 2.0mm,
3.0mm
Packing Style
Label Style
OM1,OM2,OM3,OM4
OFNR & LSZH & OFNP
905 Ferrule Type
Zirconia & Metal 906 Zirconia Ferrule 905 & 906 Two Style
Applications
Medical,Surgial,Lasers
Aesthetic lasers
Spectrometers
Indudtrial
PARAMETERS
Item
Insertion Loss
Return Loss
52
Model Type
PC
SM
≤0.3dB
MM
≤0.2dB
SM
≥50dB
MM
≥20dB
Operating Temperature
–40 C to +75 C
Durability
≤0.2 dB typical change , 500 matings
Available Wavelengths
SM = 1310 & 1550 nm , MM = 850nm
Cable Diameter Options
0.9mm, 2.0mm, 3.0mm, others
“The new era of telecommunication”
www.erattelekom.com.tr
MPO-MPO Patch Cord Series
Patch Cord Series
1
MPO-MPO
Features
Ordering Choice
High return loss
Low insertion loss
IEC61754-7 Compliant
Compect design,up to 12 fiber ribbon
Fan - out cable type
Bare Fiber Type
Ribbon Cable Type
12 color Cable
Loose & Tight Buffer
Boot Color
Packing Style
Label Style
Angle =8deg.
G652D, G657
OM1,OM2,OM3,OM4
OFNR & LSZH & OFNP
Male & Female Type
MPO Caset
Sc & LC 12 core & 24 core
Applications
CATV,LANs,Telecom,Video
Active device termination
Telecommunication networks
Gigbit Applications ( ATM,Ethernet )
PARAMETERS
Item
Insertion Loss
Return Loss
Model Type
PC
UPC
APC
SM
≤0.3dB
≤0.4dB
≤0.4dB
MM
≤0.3dB
≤0.4dB
≤0.4dB
SM
≥20dB
≥50dB
≥60dB
MM
≥20dB
≥50dB
≥60dB
Operating Temperature
–40 C to +75 C
Durability
≤0.2 dB typical change , 500 matings
Available Wavelengths
SM = 1310 & 1550 nm , MM = 850nm
Cable Diameter Options
0.9mm, 2.0mm, 3.0mm, others
“The new era of telecommunication”
www.erattelekom.com.tr
53
54
“The new era of telecommunication”
www.erattelekom.com.tr
FIBER OPTIC SPLICE ON CONNECTOR
E
H
T
W
E
N
A
R
E
F
O
N
O
I
T
A
IC
N
U
M
M
O
C
E
L
E
T
ONLY
FIBER OPTIC SPLICE ON CONNECTOR
“The new era of telecommunication”
www.erattelekom.com.tr
55
56
“The new era of telecommunication”
www.erattelekom.com.tr
FTTx Swift Connector
Connector Series
Adapter
Swift SC Connectors
Boot Type
Swift Connectors
(2.0-3.0mm,
Indoor Cable)
Swift Connectors
(0.9mm Fiber)
Key Features
Clamp Type Swift Connectors
(2.0-3.0mm, Indoor Cable)
Accordance with IEC61754,
KS C6974 [F04], JIS C5973 F04
Corresponding Telcordia GR-326-CORE
Composed of Four parts, after splicing can be easily assembled connector with one-touch system
Connector series satisfies Vertical Burn Test.Materials comply to UL94V-0
Housing Color: SM-UPC(BLUE), SM-APC(GREEN), MM(BEIGE)
SPECIFICATIONS
Item
Single Mode(SM)
UPC
Fiber
APC
SM 9/125
Insert ion Loss
Return Loss
Multi Mode(MM)
UPC
OM1(MM62.5/125)
OM2(MM50/125)
≤ average 0.2dB (≤max 0.3dB)
≥50 dB
≥60 dB
-
Tensile Strength
≥34.3N(≥3.5kgf ) for 0.9mm Fiber
≥60N (6.1Kgf ) for 2.0, 3.0mm cable, İndoor Cable
Reperating
Operation Test
500 Cycle, ≤0.2dB
Temperature Range
-40 C / 85 C
Code
0.9mm, 2.0, 2.4, 3.0mm Cable, Indoor cable(2mm x 3mm)
“The new era of telecommunication”
www.erattelekom.com.tr
57
FTTx Swift Connector
Connector Series
Swift LC Connectors
LC Duplex Type
(2.0mm)
LC Simplex Type
(0.9mm)
LC Simplex Type
(2.0mm)
Key Features
Telcordia GR-326-core tested
Accordance with IEC61754-20, TIA/EIA604-10-A
Enhanced high quality with improved optical features (Splice Loss & Return Loss)
Enhanced & Improved highly tensile strength (less than 40N)
Satisfied with Vertical Burn Test. Materials compliance with UL94V-0
Housing Color : SM-UPC(Blue), SM-APC(Green), MM(Beige)
SPECIFICATIONS
Item
Single Mode(SM)
UPC
Fiber
58
APC
SM 9/125
Insert ion Loss
Return Loss
Multi Mode(MM)
UPC
OM1(MM62.5/125)
≤ average 0.2dB (≤max 0.3dB)
≥50 dB
≥60 dB
-
Tensile Strength
≥40N for 0.9mm, 2.0mm Fiber
Reperating
Operation Test
500 Cycle, ≤0.2dB
Temperature Range
-40 C / 85 C
Code
0.9mm, 2.0 Cable
“The new era of telecommunication”
www.erattelekom.com.tr
OM2(MM50/125)
FTTx Swift Connector
Connector Series
Adapter
Swift FC Connectors
Swift Connector
(After Assembly)
(2.0-3.0mm Cable)
Swift Connector
(Before Assembly)
Swift Connector
(After Assembly)
(0/9mm Fiber)
Key Features
Telcordia GR-326-core tested
Enhanced & Improved highly tensile strength (exceeding 60N)
Accordance with IEC61754-13, KS C6970(F01), JIS C5970(F01)
Enhanced high quality with improved optical features(Splice Loss & Return Loss)
Composed of 4(Four) Parts, after splicing can be easily assembled with One-Touch System
Satisfied with Vertical Burn Test. Materials compliance with UL94V-0
Housing Color : SM-UPC(Blue), SM-APC(Green), MM(Beige)
SPECIFICATIONS
Item
Single Mode(SM)
UPC
Fiber
APC
SM 9/125
Insert ion Loss
Return Loss
Multi Mode(MM)
UPC
OM1(MM62.5/125)
OM2(MM50/125)
≤ average 0.2dB (≤max 0.3dB)
≥50 dB
≥60 dB
-
Tensile Strength
≥34.3N(≥3.5kgf ) for 0.9mm Fiber
≥60N (6.1Kgf ) for 2.0, 3.0mm cable, İndoor Cable
Reperating
Operation Test
500 Cycle, ≤0.2dB
Temperature Range
-40 C / 85 C
Code
0.9mm, 2.0, 2.4, 3.0mm Cable, Indoor cable
“The new era of telecommunication”
www.erattelekom.com.tr
59
ST Adapter Series
Adapter Series
1
ST Simplex Metal
2
ST Duplex Metal
3
ST Simplex Plastic
4
ST Duplex Plastic
Features
Applications
High return loss
Low insertion loss
100% Optic test (Insertion Loss)
CATV,Metro,LANs & military
Active device termination
Telecommunication networks
SPECIFICATIONS
Insertion Loss
60
≤0.2 dB
≤0.2 dB
Operating Temperature
–40 C to +75 C
Durability
≤0.2 dB typical change , 500 matings
“The new era of telecommunication”
www.erattelekom.com.tr
SC Adapter Series
SC SM SX
2
SC SM SX (APC)
3
SC MM SX
4
SC SM DX
5
SC SM DX (APC)
6
SC MM DX
Features
Applications
High return loss
Low insertion loss
100% Optic test (Insertion Loss)
CATV,Metro,LANs & military
Active device termination
Telecommunication networks
Adapter Series
1
SPECIFICATIONS
Insertion Loss
≤0.2 dB
≤0.2 dB
Operating Temperature
–40 C to +75 C
Durability
≤0.2 dB typical change , 500 matings
“The new era of telecommunication”
www.erattelekom.com.tr
61
LC Adapter Series
Adapter Series
1
LC SM SX
2
LC MM SX
3
LC SM QUAD
4
LC APC DX
5
LC SM DX
6
LC MM DX
7
LC MM QUAD
8
LC OM3 DX
Features
Applications
High return loss
Low insertion loss
100% Optic test (Insertion Loss)
CATV,Metro,LANs & military
Active device termination
Telecommunication networks
SPECIFICATIONS
Item
Insertion Loss
62
Single Mode(SM)
Multi Mode(MM)
≤0.2 dB
≤0.2 dB
Operating Temperature
–40 C to +75 C
Durability
≤0.2 dB typical change , 500 matings
“The new era of telecommunication”
www.erattelekom.com.tr
FC Adapter Series
FC Square
2
3
FC FLANGE
FC D ROUND
Features
Applications
High return loss
Low insertion loss
100% Optic test (Insertion Loss)
CATV,Metro,LANs & military
Active device termination
Telecommunication networks
Adapter Series
1
SPECIFICATIONS
Item
Insertion Loss
Single Mode(SM)
Multi Mode(MM)
≤0.2 dB
≤0.2 dB
Operating Temperature
–40 C to +75 C
Durability
≤0.2 dB typical change , 500 matings
“The new era of telecommunication”
www.erattelekom.com.tr
63
Adapter Series
Adapter Series
1
2
E2000 (PC)
4
3
E2000 (APC)
5
MTRJ (PC)
MU (PC)
MPO (PC)
Features
Ordering Choice
High return loss
Low insertion loss
100% Optic test (Insertion Loss)
Sleeve
Zirconia
Adapter Color
Blue,Green,Beige
Applications
CATV,Metro,LANs & military
Active device termination
Telecommunication networks
SPECIFICATIONS
64
Specifications
SM
MM
Insertion Loss
≤0.2 dB
≤0.2 dB
Return Loss
≥0.2 dB
≥0.2 dB
Operating Temperature
–40 C to +75 C
Durability
≤0.1 dB typical change , 500 matings
Available Wavelengths
SM=1310 & 1550nm,MM=850nm
“The new era of telecommunication”
www.erattelekom.com.tr
Hybrid Adapter Series
LC / FC
9
SC / ST
4
MTRJ / SC
3
SC / FC
1
4
4
SC / LC
4
MU / LC
Hybrid Adapter Series
7
FC / ST
MU / SC
Features
Applications
Ordering Choice
High return loss
Low insertion loss
100% Optic test (Insertion Loss)
CATV,Metro,LANs & military
Active device termination
Telecommunication networks
Sleeve
Zirconia
Adapter Colour
Blue
SPECIFICATIONS
Specifications
SM
MM
Insertion Loss
≤0.2 dB
≤0.2 dB
Return Loss
≥0.2 dB
≥0.2 dB
Operating Temperature
–40 C to +75 C
Durability
≤0.2 dB typical change , 500 matings
Available Wavelengths
SM=1310 & 1550nm,MM=850nm
“The new era of telecommunication”
www.erattelekom.com.tr
65
Bare Adapter Series
Bare Adapter Series
1
2
SC Bare Adapter
FC Bare Adapter
Description
Bare fiber Adapters allow users to make fast connection of the bare fiber and the
fiber optic equipment, bare fiber Adapters can be used in some emergency situation for urgent connection.
Features
Applications
Compact Design
Telcordia, ANSI, TIA/EIA, NTT and JIS Compliance
High Precision Alignment
Low insertion and Return Loss
CATV
Telecommunication Networks
Local Area Networks(LAN)
Data Processing Networks
Wide Area Networks(WAN)
Industrial, Medical & Military
SPECIFICATIONS
İnsertion Loss
66
≤0.20 dB
Repeatability
≤0.10 dB
Operating Temperature
–25 C to +70 C
Storage Temperature
–40 C to +80 C
“The new era of telecommunication”
www.erattelekom.com.tr
Male To Female
Adapter Series
SC To LC
2
SC To FC
3
FC To LC
4
FC To ST
5
LC To SC
6
LC To FC
Features
Ordering Choice
High return loss
Low insertion loss
100% Optic test (Insertion Loss)
Sleeve
Zirconia Type
LC male to FC
LC male to SC
LC male to ST
Fiber
Single Mode
Multi Mode 50 / 125
Multi Mode 62.5 / 125
Applications
CATV,Metro,LANs & military
Active device termination
Telecommunication networks
Male To Female Adapter Series
1
SPECIFICATIONS
Specifications
SM
MM
APC
Insertion Loss
≤0.2 dB
≤0.2 dB
≤0.2 dB
Return Loss
≥0.2 dB
≥0.2 dB
≤0.2 dB
Operating Temperature
–40 C to +75 C
Durability
≤0.2 dB typical change , 500 matings
“The new era of telecommunication”
www.erattelekom.com.tr
67
Attenuator Series
Attenuator Series
1
ST
2
3
SC
LC
Features
Ordering Choice
High durability
Attenuation levels ringing from 1 to 30dB
Metal-ion doped fiber
Compliance with TIA/IEA,IEC,Rohs
Attenuation levels
1 dB to 30dB
LC two type
15.5mm & 21mm
SC , FC , ST , LC , MU
PC & APC Type
4
FC
Applications
EDFA,DWDM,Long-haul
Wide-Area Network
Telecommunication networks
Gigbit applications (ATM,Ethernet)
SPECIFICATIONS
SPECIFICATIONS
SM
Insertion Loss
Return Loss
68
MM
1 to 10dB: ±0.5dB , 11 to 30 dB: ±5%
≥50 dB
≥20 dB
Operating Temperature
–40 C to +75 C
Durability
≤0.1 dB typical change , 500 matings
Available Wavelengths
SM=1310 & 1550nm,MM=850nm
“The new era of telecommunication”
www.erattelekom.com.tr
APC
≥60 dB
10/100 M Fiber Ethernet
Media Converter
Converters
Features
Operating standards: IEEE802.3u 10/100 Base-TX and 100Base-FX
MAC addresses table : 1k
Data buffer: Built-in 128Kb RAM
UTP Connector: RJ-45,10/100 Mbps; Fiber connector:
ST/SC/FC,100 Mbps
Cable: UTP: Cat.5 (the max distance up to 100m)
Multimode Fiber: 50/125, 62.5/125um ( 2km or 5km)
Singlemode Fiber: 8/125, 8.7/125, 9/125, 10/125um (20-120km)
Flow Control: Full duplex: Supporting standard IEEE802.3x
Half Duplex: back pressure
LED: Power, FX SD, FX Link/Act, TX FDX, TX Link/Act
Power Requirement: AC 100 240V, 50-60Hz, DC 5V, 1A
Ambient temperature: 0 50℃; Storage temperature: -20℃ 70℃
Relative humidity: 5 90%
Dimensions: Internal power:30×110×40mm;
External power: 26×70×93mm
Ordering Choice
Connector
SC & ST
Mode
Single & Multi
Wavelength
MM - 850 / 1310 nm
SM - 1310 / 1550 nm
Max .distance
MM - 2 km
SM - 25 km to 120 km
“The new era of telecommunication”
www.erattelekom.com.tr
69
10/100/1000 M Fiber Ethernet
Media Converter
ConverterS
Features
Operating standards: IEEE802.3z/AB、1000 Base-T and 1000Base-SX/LX
MAC addresses table : 1k
Data buffer: 512Kb
Bandwidth: 12G, can be transmitted to achieve non-blocking wire-speed
Cable: UTP: Cat 5 or Cat 6 (the max distance up to 100m)
Multimode Fiber: 50/125, 62.5/125um (the max distance up to 550/224m)
Singlemode Fiber: 8/125, 8.7/125, 9/125, (the max distance up to 100m)
Flow Control: Full duplex: IEEE802.3x;
Half Duplex: back pressure
LED: Power, FX Link/Act, TP FDX, TP Link/Act, TP 100, TP1000
Power Requirement: AC 220V (100~240V), 50-60Hz, DC 5V, 2A
Ambient temperature: 0 / 50℃;
Storage temperature:-20℃ / 70℃
Relative humidity: 5/ 90%
Dmensions: 26×70×93mm ( H x W x L )
Ordering Choice
Connector
SC & LC
Mode
Single & Multi
Wavelength
MM - 850
SM - 1310 / 1550 nm
Max .distance
MM - 224 / 550 m
SM - 20 km to 100 km
70
“The new era of telecommunication”
www.erattelekom.com.tr
1000 M Gigabit Fiber Ethernet
Media Converter
Converters
Features
Operating standards: IEEE802.3z/AB, 1000 Base-T and1000Base-SX/LX
Connectors: UTP: RJ-45,1000Mbps;
Fiber: SC/LC1000Mbps
Cable: UTP cable: Cat 5e or Cat 6 (the max distance up to100m)
Multimode Fiber: 50/125, 62.5/125um
(the max distance up to 550/224m)
Singlemode Fiber: 8.3/125, 8.7/125, 9/125,the max distance up to 100m)
LED: PWR, FX SD, FX Link/Act, TP TX, TP RX, TP 100, TP 1000
Power Requirement: AC 220V (100~240V), 50-60Hz, DC 5V, 2A
Ambient temperature: 0 / 50℃;
Storage temperature: -20℃ / 70℃
Relative humidity: 5 / 90%
Dimensions: 26×70×93mm( H x W x L )
Ordering Choice
Connector
SC & LC
Mode
Single & Multi
Wavelength
MM - 850
SM - 1310 / 1550 nm
Max .distance
MM - 224 / 550 m
SM - 20 km to 100 km
“The new era of telecommunication”
www.erattelekom.com.tr
71
72
“The new era of telecommunication”
www.erattelekom.com.tr
FIBER OPTIC PATCH PANELS
E
H
T
W
E
N
A
R
E
F
O
N
O
I
T
A
IC
N
U
M
M
O
C
E
L
E
T
ONLY
FIBER OPTIC PATCH PANELS
“The new era of telecommunication”
www.erattelekom.com.tr
73
1 U Rack Type
Patch Panels
19” Rack Type
74
Features
Colors
Suitable for 12’ Rack Mounted
1 U Height (44mm)
Sliding Panel Structure
Easy Montage
Suitable Cable Port for PC (PG16) Connection
Connection Point to fix Fiber Casette
Steel Constructional Structure
Dimensions: W483*D230*H44mm, Weight 2.4 KG.
RAL 9005 Black (Standart)
RAL 7035 White (Optinal)
“The new era of telecommunication”
www.erattelekom.com.tr
1 U Rack Type
24 Port SC Duplex
12 Port ST Simplex
24 Port ST Simplex
12 Port LC Duplex
24 Port LC Duplex
12 Port FC Simplex
Patch Panels
24 Port SC Duplex
12 Port ST Duplex
“The new era of telecommunication”
www.erattelekom.com.tr
75
2 U Rack Type
Patch Panels
19” Sliding Rack Type
76
Features
Colors
Suitable for 12’ Rack Mounted
2 U Height (44mm)
Sliding Panel Structure
Easy Montage
Suitable Cable Port for PC (PG16) Connection
Connection Point to fix Fiber Casette
Steel Constructional Structure
Totally Unfixed Below Tray via Sliding Panel
Angled Adaptör Placement
Connection Points for Bend Redius
Dimensions: W483*D245*H44mm, Weight: 5 KG
RAL 9005 Black (Standart)
RAL 7035 White (Optinal)
“The new era of telecommunication”
www.erattelekom.com.tr
3 U Terminton Patch Panels
Patch Panels
19” Sliding Rack Type
Features
Colors
Suitable for 19’ -21’ Rack Mounted
3 U Height (133mm)
On, Side and Back Cable Port
Modular Front Panel Structure
Easily Openable Hinged Plexiglas Front Cover
Easily Openable Back Cover
Fiber Casette Support for Fiber Montage
Steel Constructional Structure
Dimensions: W483*D330*H133mm, Weight: 7.5 KG
RAL 9005 Black (Standart)
RAL 7035 White (Optinal)
“The new era of telecommunication”
www.erattelekom.com.tr
77
4 U Termination Patch Panels
Patch Panels
4U Terminations Patch Panel
78
Features
Colors
Suitable for 19’ Rack Mounted
4 U Height (178mm)
Sliding side lobe
On and Side Cable Port
Modular Front Panel
Easily Openable front and back Cover
Fiber Casette support for multi casettes
Steel Constructional Structure
Dimensions: W483*D405*H178mm, Weight: 8 KG
RAL 9005 Black (Standart)
RAL 7035 White (Optinal)
“The new era of telecommunication”
www.erattelekom.com.tr
Wall Mounted Type Fiber Optic
Patch Panels
Patch Panels
Wall Mounted S Type Fiber
Optic Patch Panels
Features
Suitable for Wall Mounted
Lockable Front Cover
Easily Mountage
Suitable Cable Port for PC (PG16) Connection
Steel Contructional Structure
Dimensions: W170*D210*H44mm, Weight: 0.9 KG
Colors
RAL 9005 Black (Standart)
RAL 7035 White (Optinal)
“The new era of telecommunication”
www.erattelekom.com.tr
79
Wall Mounted Type Fiber Optic
Patch Panels
Patch Panels
Wall Mounted M Type Fiber
Optic Patch Panels
Features
Suitable for 19’ -21’ Rack Mounted
3 U Height (133mm)
On, Side and Back Cable Port
Modular Front Panel Structure
Easily Openable Hinged Plexiglas Front Cover
Easily Openable Back Cover
Fiber Casette Support for Fiber Montage
Steel Constructional Structure
Dimensions: W320*D255*H88mm, Weight: 2.5 KG
Colors
RAL 9005 Black (Standart)
RAL 7035 White (Optinal)
80
“The new era of telecommunication”
www.erattelekom.com.tr
Wall Mounted Type Fiber Optic
Patch Panels
Patch Panels
Wall Mounted B Type Fiber
Optic Patch Panels
Features
Suitable for Wall Mounted
Lockable Front Cover
Easily Mountage
Modular Inner Panel Structure
4 Different Cable Ports
Montage Holes For Casettes’ Connection
Steel Contructional Structure
Dimensions: W430*D335*H133mm, Weight: 5.6 KG
Colors
RAL 9005 Black (Standart)
RAL 7035 White (Optinal)
“The new era of telecommunication”
www.erattelekom.com.tr
81
Wall Mounted Type Fiber Optic
Patch Panels
Patch Panels
Wall Mounted D Type Fiber
Optic Patch Panels
Features
Suitable for Wall Mounted
Lockable Dual Welded Front Cover
Easily Mountage
Modular Inner Panel Structure
6 Different Cable Ports
Montage Holes For Casettes’ Connection
Steel Contructional Structure
Dimensions: W420*D335*H133mm, Weight: 5.3 KG
Colors
RAL 9005 Black (Standart)
RAL 7035 White (Optinal)
82
“The new era of telecommunication”
www.erattelekom.com.tr
Date:...../...../........
“The new era of telecommunication”
www.erattelekom.com.tr
83
Splitters
Splitters
Pigtail Cassette PLC Spliter
Micro Moduler PLC Spliter
PLC Splitter
Descriptions
1xN/2xN PLC splitters based on planar lightwave circuit technology and precision aligning
process can divide a single/dual optical input(s) into multiple optical outputs uniformly, and
offer superior optical performance, high stability and high reliability to meet various application
requirements. Our standard modules with PLC Splitter have “Bare-Type”, “Micro Modular-Type”
, “Cassette-Type”, “ ODF-Type “. We can also have the customization dimension.
Features
1.
2.
3.
4.
5.
Low Insertion loss
Low PDL
High Return Loss
Compact Design
Uniform Power Splitting
6. Wide Operating Wavelength
7. Wide Operating Temperature
8. High Reliability and Stability
9. Qualified Under Telcordia GR-1221-COR and GR-1209-COR
10. Telecordia Compliance
Applications
Passive Optical Networks (PON)
Cable Television (CATV Links)
Local Area Networks (LAN)
Test Equipments
Optical Signal Distribution
FTTX Deployments (FTTP, FTTH, FTTN, FTTC, FTTB)
Package information :
Dimen
nsion ( LxWxH ) mm
84
No.S
plitters
Micro Modular typeC
assette-Type
ODF Type
12
x2
60*7*41
00*80*10
485×200×50
21
x4
60*7*41
00*80*10
485×200×50
32
x4
60*7*41
00*80*10
485×200×50
41
x8
60*7*41
00*80*10
485×200×50
52
x8
60*7*41
00*80*10
485×200×50
6
1x16
60*12*4
120*80*18
485×200×50
7
2x16
60*12*4
120*80*18
485×200×50
8
1x32
80*20*6
120*80*18
485×200×50
9
2x32
80*20*6
120*80*18
485×200×50
10
1x64
100x40x61
41*115*18
485×200×88
“The new era of telecommunication”
www.erattelekom.com.tr
Splitters
Splitters
2xN Splitter
Micro Modular type
ODF Type
The Optical Performance of PLC Splittter
Parameter
Unit
1x
1x2
1x4
1x8
2x
1x1
1x 2
1x 4
2x4
2x8
2x1
2x 2
2x 4
Premi m ra e P
Insertion Loss
(at 23°C)
Channel
Uniformity
PDL
Max. dB
0.1
0.1
0.1
0.2
0.2
0.2
0.1
0.1
0.2
0.2
0.2
WDL
Max. dB
0.1
0.1
0.1
0.1
0.2
0.2
0.1
0.1
0.1
0.2
0.2
Max. dB
3.8
6.8
10.2
13.2
16.5
1 .5
7
10.5
13.5
16.5
20
Max. dB
0.4
0.5
0.5
1
1
2
0.8
1
2.5
2
2
TDL
Max dB
Max.
03
0.3
03
0.3
03
0.3
04
0.4
04
0.4
04
0.4
03
0.3
03
0.3
04
0.4
04
0.4
04
0.4
CDL
Max. dB
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
Stan ar
ra e
Insertion Loss
(at 23°C)
Channel
Uniformity
PDL
Max. dB
4.2
7.1
10.5
13.5
16.8
20.2
7.5
10.8
13.8
16.8
20.5
Max. dB
0.6
0.6
0.8
1.2
1.5
2.5
1
1.5
2
2.5
2.5
Max. dB
0.15
0.15
0.25
0.3
0.3
0.3
0.2
0.3
0.4
0.4
0.4
WDL
Max. dB
0.2
0.2
0.3
0.5
0.5
0.5
0.2
0.3
0.5
0.5
0.5
TDL
Max. dB
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
CDL
Max. dB
0.5
0.4
0.3
0.3
0.2
0.8
0.3
0.3
0.3
0.3
0.3
Operating
Wavelength
Return Loss
Min. dB
55
Directivity
Min. dB
55
Operating
Temperature
Storage
T
Temperature
t
i erLength
i erType
1.
1260
°C
°C
C
m
1650
40 85
40
1.0 m
85
or Customi ed
Complied to ITU
Connector Type
otes
nm
.652D
.657
Customi ed
ll measurements ere done at room tempera
ature ithout connectors.
2. The a ove specification is under no connector. If including connector Insertion Loss ould increase the value as should in
CDL respectively.
ti l
3. P L
Polari ation
Dependent Loss
L
Wa
velength Dependent Loss T L
Temperature DependentLoss C L
Connector Dependent Loss.
“The new era of telecommunication”
www.erattelekom.com.tr
85
Fiber Dome Closure
Heat Shrink - L5
Fiber Optic Closures
Features
Constructed of highly chemical-resistance material
Built-in integral multipurpose fiber storage system
Innovative latching/locking o-ring closure sealing system
Heat shrink cable seal
Hinged tray design
Modular splice holder design
Common accessories and installation procedures
Benefits
Can be deployed in most environments: aerial, buried and
underground
Provides separate area for sorting, routing, protecting, and
“expressing” buffer tubes, single and ribbon fibers
Designed to allow for a simple, watertight
closure-sealing and re-entry
High quality and reliable environmental sealing
Easy access to fibers/splices without removing other trays
Accommodates various fiber splice types: single fiber and ribbon mass (4-fiber, 6-fiber, 8-fiber and 12-fiber) fusion
Enhances productivity, reduces inventory of accessories (splice
trays, cable entry kits) and decreases training time
FEATURES
Feature
Dimensions (L x D x W) mm (in.)
510 x 180 (20.1 x 7.1)
Cable entry ports and size
Round ports: 5 10 to 20 mm (0.4 in. to 0.76 in.)
Oval port: 1 10 to 25 mm (0.4 in. to 1.0 in.)
Closure material
Polypropylene
Closure sealing system
O-ring & clamping system
Cable sealing system
All ports: heat shrink
Splice tray
Number of splice trays
86
FDC-HS-L5
2533
Discrete: 6
Ribbon: 6
Splice capacity*
Discrete: 144
*Ribbon: 4/6 ribbon fiber = 288/432
8/12 ribbon fiber = 480/720
Grounding
# of feed-thru studs: 0, 1 or 2
Flash test (w/optional air valve installed)
Yes; 10 PSI (69 kPa)
“The new era of telecommunication”
www.erattelekom.com.tr
Fiber Dome Closure
Heat Shrink - S4
Fiber Optic Closures
Features
Constructed of highly chemical-resistance material
Built-in integral multipurpose fiber storage system
Innovative latching/locking o-ring closure sealing system
Heat shrink cable seal
Hinged tray design
Modular splice holder design
Common accessories and installation procedures
Benefits
Can be deployed in most environments: aerial, buried and
underground
Provides separate area for sorting, routing, protecting, and
“expressing” buffer tubes, single and ribbon fibers
Designed to allow for a simple, watertight
closure-sealing and re-entry
High quality and reliable environmental sealing
Easy access to fibers/splices without removing other trays
Accommodates various fiber splice types: single fiber and ribbon mass (4-fiber, 6-fiber, 8-fiber and 12-fiber) fusion
Enhances productivity, reduces inventory of accessories (splice
trays, cable entry kits) and decreases training time
FEATURES
Feature
FDC-HS-S4
Dimensions (L x D x W) mm (in.)
460 x 160 (18.1 x 6.3)
Cable entry ports and size
Round ports: 5 10 to 20 mm (0.4 in. to 0.76 in.)
Oval port: 1 10 to 28 mm (0.4 in. to 1.0 in.)
Closure material
Polypropylene
Closure sealing system
O-ring & clamping system
Cable sealing system
All ports: heat shrink
Splice tray
2533
Number of splice trays
Discrete: 2 Ribbon: 2
Splice capacity*
Discrete: 48
*Ribbon: 4/6 ribbon fiber = 96/144
8/12 ribbon fiber = 160/240
Grounding
# of feed-thru studs: 0 or 1
Flash test (w/optional air valve installed)
Yes; 10 PSI (69 kPa)
“The new era of telecommunication”
www.erattelekom.com.tr
87
ILSINTECH
THE NEW ERA OF TELECOMMUNICATION
88
“The new era of telecommunication”
www.erattelekom.com.tr
FIBER OPTIC FUSION SPLICER
E
H
T
W
E
N
A
R
E
F
O
N
O
I
T
A
IC
N
U
M
M
O
C
E
L
E
T
ONLY
FIBER OPTIC FUSION SPLICER
“The new era of telecommunication”
www.erattelekom.com.tr
89
FTTx Smallest Fusion Splicer
Fiber Optic Fusion Splicer
Swift-F3
FTTx Smallest
Fusion Splicer
Features
Applicable for SOC(splicer on connector)
Smallest, Lightest, Fastest
Most Reasonable Price ver Best Quality
Resistance to Shock, Rain, Dust, 100% Proven by Field Test
Efficient Two Heater System
Standard Packing
Optional Packing
90
“The new era of telecommunication”
www.erattelekom.com.tr
FTTx Smallest Fusion Splicer
Subject
Description
Fiber Alignment
Fixed V - Groove(Clad to Clad)
Size of Clad
125µm
Size of Coating
250 ~ 900 µm
Aver Loss Ratio
0.03dB (SM), 0.02dB( MM), 0.06dB (NZDS, DS)
Splicing time
7sec
Heating sleeve
20sec (0.9mm ), 70Sec (Indoor, 3.0mm)
Length of Sleeve
60mm/40mm
Strength of Tensile
1.96N
Storage of Data
2,000
Applicable cable
0.25mm, 0.9mm, 2.0mm, 3.0mm, Indoor Cable
Size
140(W) µm 179(L) µm 87(H) mm
Weight
1.2 Kg (Include Rubber, Battery 2ea)
Power
DC Li-Polymer Battery, 100~240V AC Adapter
External Power
DC 12V appicable for Car Cigar Jeck
Capacity of Battery
1400 mAh µm 2
Life time of Battery
Typical 140 cycles(0.9mm fiber)
Operating Temperature
-10 µm~ 50 µm
Storage Temperature
-40 µm ~ 80 µm
Fiber Optic Fusion Splicer
SPECIFICATIONS
Sleeve Heater
Splicer
Control
LCD Monitor
“The new era of telecommunication”
www.erattelekom.com.tr
91
FTTx All in One Fusion Splicer
Fiber Optic Fusion Splicer
Swift-F1
FTTx All in One
Fusion Splicer
Features
The Single All-in-one Device (strip, clean, cleave, splice, sleeve)
Operation time : 60 sec (incl. connector assembly, 0.9mm fiber)
No crack with heating stripping, more then 3.5kgf
No matter who or when, even a beginner can use easily
Standard Packing
Optional Packing
Subject
Model
Q'ty
Description
Splicer
F1
1
Working Table
AC Adapter
F1-1
1
Battery Charger
F1-2
1
Battery Pack
F1-B
2
Electrode
EI-19
Fiber Holder
HF-?
Option
1Set(2EA)
Blade
BI-05
Spare Electrode
EI-19
1pair
DC Adapter
F1-DA
Cooling tray
CT
1
Battery Pack
F1-B
Carrying Case
Soft Case
1
Sleeve Heater lever
Block
See page 5
User Guide CD
Fiber Holder
1
Sleeve
92
“The new era of telecommunication”
www.erattelekom.com.tr
Model
WK
HF-250, HF-900, HF-2.5, HF-IN
Electrode
S09-C
0.9mm Connector, 1.0x2.3x28mm
S09
0.9mm Cable, 1.0x2.3x45mm
S30-C
3.0mm. Indoor Connector,
3.5x4.0x32mm
S30
3.0mm. Indoor Connector,
3.5x4.0x45mm
FTTx All in One Fusion Splicer
Fiber Optic Fusion Splicer
SPECIFICATIONS
Subject
Description
Alignment
Fixed V - Groove (Clad to Clad)
Cladding Diameter
125µm
Coating Diameter
250 ~ 900µm
Average Splice Loss
0.03dB(SM), 0.02dB(MM), 0.06dB(NZDS,DS)
Splicing Time (Typical)
7sec
Heating Time
15sec(0.9mm Fiber), 70sec(Indoor, 3.0mm Cable)
Sleeve Length
45mm(For Fiber), 28mm or 32mm(For Connector)
Tension Test
1.96N
Splice Memory
2000
Compatible Cable
0.25mm, 0.9mm, 2.0mm, 3.0mm, Indoor Cable
Dimension
135(W)x200(L)x82(H) mm
Weight
1.5Kg (Body 1.1kg, Battery 120gX2)
Power
DC Li-Polymer Battery, 100~240V AC Adapter
Battery Capacity
1400mAhx2
No. of Splicing/Heating with battery
Typical 120cycles(0.9mm Fiber)
Operating Temp
-10°C~ 50°C
Storage Temp
-40°C~ 80°C
Storage Temperature
-
Cleaver with Fiber
Chip Collector
Fusion Splicer
Sleeve Oven
Automatic Thermal
Stripper with Motor
LCD Monitor
Cleaner
Batteries 2ea
“The new era of telecommunication”
www.erattelekom.com.tr
93
Core Alignment Fusion Splicer
Fiber Optic Fusion Splicer
Swift-S3
Core Alignment
Fusion Splicer
Features
Core Alignment by IPAS Technology
Resistant Shock, Dust andRain
Powerful Battery with Large Capacity
Dual Sleeve Heater
Automatic Execution of Discharge Calibration
Compatible for SOC Connector(Option)
Standard Packing
Description
Model
Q'ty
Fusion Splicer
S3
1
AC Adapter
S311
1
Sleeve Loader
S312
2
Spare Electrodes
EI-21
1
Battery Pack
S313
1
Alcohol Dispenser
Cooling Tray
94
1
CT
1
Sleeving Clamp
SC-01
1
Manual Stripper
MS-01
1
Carrying Case
1
User Manual
1
“The new era of telecommunication”
www.erattelekom.com.tr
Smallest, Lightest & Fastest
4.3” Color LCD Monitor with Touch Panel
Bidirectional Operation System
Attached Sleeve Loader
Attached Night Light
ROHS Compliant
Core Alignment Fusion Splicer
Subject
Description
Alignment
IPAS Core to Core Alignment (Image Pattern Analysis Alignment System)
Applicable fibers
SMF(ITU-T G.652), MMF(ITU-T G.651), DSF(ITU-T G.653), NZDSF(ITU-T G.655),
EDFA, EI980, Splicing available with different type fiber(SM/MM), ITU-T G.657
Fiber Diameter
cladding : 80µm ~ 150µm , coating : 100µm ~ 1000µm (single)
Fiber cleave length
250µm (Coat) : 8 ~ 16mm, 900µm : 16mm
Typical splice loss
SMF : 0.02dB, MMF : 0.01dB, DSF : 0.04dB, NZDSF : 0.04dB
Return loss
Less then -60dB
SPLICE Time
SPLICE : Typical 9sec, Tube Heat : Typical 26sec with S-160(60mm) Tube
Program
SPLICE Mode : 100, Heat Mode : 50
Storage of splice result
the last 2,000 results (Image 100 results)
Operating altitude
0 ~ 5000m above sea level
Operating condition
-10°C to 50 , humidity : 95%, non-Condensing
Storage condition
-40°C to 80 , 0 to 95% RH
Protection
Wind 15M/S , shock proof, water proof, dust proof
SIZE, Weight
138W X 160L X 135H (include Monitor & Rubber), 2.3Kg (include Battery)
Terminal
USB, RCA, External Power
Power
DC 14.8V Battery (5600mAh), 100 ~ 240V AC Adapter
Additional power
DC 12V automobile power outlet available
No of splice/Heating with Battery
250cycle, lithium polymer batteries
Electrode
more than 2,500 times splicing without exchange
Mechanical proof test
2N / 4.4N (OPTION)
Display
Two CMOS cameras and 4.3" color LCD monitor, with touch panel
Fiber view and magnification
X/Y 300X, 187X
Fiber Optic Fusion Splicer
SPECIFICATIONS
Optional Packing
Description
Model
Connector Holder
HS-SC, LC, FC, ST Refer to All in one
Swift F1 catalog
Cleaver Blade
BI-05
Fiber Cleaver
CS-03B, CI-01, CI-03A
Battery Pack
S313
Protection Sleeves
S-160(60mm), S-140(40mm)
Manual Stripper
MS-01
SOC Connector
SC, LC, FC, ST Refer to SOC catalog
“The new era of telecommunication”
www.erattelekom.com.tr
95
Core Alignment All in one Fusion Splicer
Fiber Optic Fusion Splicer
Swift-S5
Core Alignment All in one
Fusion Splicer
Features
96
Integrated to all-in-one
Ruggedizing designed against shock, dust, rain
Long battery life more than 320times full-cycling
Dual sleeve heater
No crack on bare fiber by heating stripping
Navigational touch screen with 4.3 color monitor
Attached sleeve loader
Compatible for SOC connector
Standard Packing
Optional Packing
Description
Model
Q'ty
Fusion Splicer
with Auto Stripper,
S5
S5
Cleaner unit, and
Cleaver
S311
S311
Description
Model
Spare Battery
S513
Spare Cleaver
CI-05
Cleaver Blade
BI-05
Electrode
EI-21
S-160(60mm), S-140(40mm)
AC Adapter
S312
S312
Protection Sleeves
Sleeve Loader
EI-21
EI-21
Spare Electrodes
S513
S513
SOC Connector
SC, LC, FC, ST, CH Refer to SOC
catalog
Battery Pack
EI-19
1pair
Connector Holder
HS - SC, LC, FC, ST
Refer to All in one Swift F1 catalog
Carrying Case
1
User Manual
1
“The new era of telecommunication”
www.erattelekom.com.tr
Core Alignment All in one Fusion Splicer
Subject
Alignment
Applicable fibers
Fiber Diameter
Description
IPAS Core to Core Alignment (Image Pattern Analysis Alignment System)
SMF(ITU-T G.652), MMF(ITU-T G.651), DSF(ITU-T G.653), NZDSF(ITU-T G.655),
EDFA, EI980, Splicing available with different type fiber(SM/MM), ITU-T G.657
cladding : 80µm ~ 150µm , coating : 100µm ~ 1000µm (single)
Fiber cleave length
250µm (Coat) : 8 ~ 16mm, 900µm : 16mm
Typical splice loss
SMF : 0.02dB, MMF : 0.01dB, DSF : 0.04dB, NZDSF : 0.04dB
Return loss
Less then -60dB
SPLICE Time
SPLICE : Typical 9sec, Tube Heat : Typical 20 ~ 26sec with S-160(60mm) Tube
Program
SPLICE Mode : 100, Heat Mode : 50
Storage of splice result
the last 2,000 results (Image 100 results)
Operating altitude
0 ~ 5000m above sea level
Operating condition
-10°C to 50°C , humidity : 95%, non-Condensing
Storage condition
-40°C to 80°C , 0 to 95% RH
Protection
Wind 15 , shock proof, water proof, dust proof
SIZE, Weight
140W 225L 125H (include Monitor & Rubber), 2.95Kg (include Battery)
Terminal
USB, RCA, External Power
Power
DC 14.8V Battery (7700mAh), 100 ~ 240V AC Adapter
Additional power
DC 12V automobile ciger jack available
No of splice/Heating with Battery
320 cycle, lithium polymer batteries
Electrode
more than 2,000 times splicing without exchange
Mechanical proof test
2N / 4.4N (OPTION)
Display
Two CMOS cameras and 4.3" color LCD monitor, with touch panel
Fiber view and magnification
X/Y 300X, 170X
Fiber Optic Fusion Splicer
SPECIFICATIONS
Cleaver with Fiber
Chip Collector
Fusion Splicer
Sleeve Oven
Automatic Thermal
Stripper with Moto
LCD Monitor
Cleaner
Batteries 2ea
“The new era of telecommunication”
www.erattelekom.com.tr
97
Ribbon All in one Fusion Splicer
Fiber Optic Fusion Splicer
Swift-R1
Ribbon All in one
Fusion Splicer
Features
All-In-One Integrated Unit
(stripping, cleaning, cleaving, splicing, and sleeving)
Applicable for 12Core, 8Core, 4Core, 2Core Ribbon
and Single Fiber, and for Splice-on Connector
Fiber Stripping by Motorized Automatic Thermal Stripper
Standard Packing
Description
Model
Q'ty
Splicer
R1
1
AC Adapter
AC-A
1
Battery Charger
F1-2
1
Battery Pack
F1-B
2
Battery Pack
EI-20
Fiber Holder
HR-12
1set
Ribbon Sleeve
BI-05
Spare Electrode
EI-20
1set
Working Table
F1-B
Carrying Case
Hard Case
1
Swift Connector
R-F40(40mm)
Cooling Tray
CT
1
HS - SC, LC, FC, ST
Refer to All in one Swift
F1 catalog
WK
Connector Holder
Refer to Swift Connector Catalog
Manual
98
Optional Packing
“The new era of telecommunication”
www.erattelekom.com.tr
1
Description
Model
HR-12, HR-8, HR-4, HR-2,
Fiber Holder
Electrode
Blade
Ribbon All in one Fusion Splicer
Subject
Applicable fibers
Fiber Diameter
Description
SM(ITU-T G.652), MM(ITU-T G.651), DS(ITU-T G.653), NZDS(ITU-T G.655)
Ribbon : Cladding diameter125µm, Ribbon fiber thickness 0.27 to 0.32mm
Single : Cladding diameter125µm, Coating diameter 250µm and 900µm
Fiber cleave length
10mm
Typical splice loss
0.05dB with SM, 0.02dB with MM, 0.08dB with DS, 0.08dB with NZDS.
Return loss
<60dB
SPLICE Time
Typical 20sec with standard SM(ITU-T G.652)
Program
SPLICE Mode : 100, Heat Mode : 50
Storage of splice result
The last 2000 results to be stored in the internal memory.
Operating altitude
0 to 3660m above sea level
Operating condition
-10°C to 50°C, humidity : 95%, non-Condensing
Storage condition
-40°C to 80°C, 0 to 95% RH
Wind protection
15m/s
SIZE, Weight
135mmX200mmX82mm, 1.6kg
Terminal
USB, External Power
Power
DC 14.8V Battery, 100 ~ 240V AC Adapter
No of splice/Heating with battery
90cycle
Sleeve heating time
35sec
Tension test
2N
Display
Two CMOS cameras and 3.5" color LCD monitor.
Fiber view and magnification
X/Y 35X
Display
Two CMOS cameras and 4.3" color LCD monitor, with touch panel
Fiber view and magnification
X/Y 300X, 170X
Fiber Optic Fusion Splicer
SPECIFICATIONS
Cleaver with Fiber
Chip Collector
Sleeve Oven
Automatic Thermal
Stripper with Moto
Cleaner
Fusion Splicer
LCD Monitor
Batteries 2ea
“The new era of telecommunication”
www.erattelekom.com.tr
99
SWIFT CLEAVER TYPES
Cleavers
Swift CI-01
Wrench attached
Blade BI-05
Technical Specification
Key Features
Economic Price
Stable Operation by Step-Action Process
Compact Design
High Precision Blade with 16 Cleave Spots
Fiber Diameter
125μm
Coating Diameter
250 ~ 900μm
Cleave Angle
90° ± 0.5°
Cleave Length
Single 5mm ~ 20mm
Blade Life time
50,000
Outfit Dimension
58 x 55 x 48mm
Weight
340g
Swift CI-02
Slider bearing
Key Features
Stable Long Life by adopting Double
Slide Bearing System
Oil Damper System
Single Automatic Action for Cleaving and
Fiber Chip Collection
Approx. 20,000 times cleaving available
with Diamond Chip Blade Head
100
“The new era of telecommunication”
www.erattelekom.com.tr
Blade BI-05
Technical Specification
Fiber Diameter
125μm
Coating Diameter
Cleave Angle
90° ± 0.5°
Cleave Length
Blade Life time
50,000
Outfit Dimension
84 x 65 x 54mm
Weight
420g
SWIFT CLEAVER TYPES
Cleavers
Swift CI-03
Blade BI-05
Key Features
Single Action (Full Automatic)
Oil Damper System
Compact Design
Swift CI-03B
Technical Specification
Key Features
Single Action for Cleaving & Fiber Chip
Collection
Oil Damper System
High Precision Blade with 16 Cleave Spots
Diamond Blade with 1 Million Cleave Life
(Option)
CI-03A
CI-03B
Fiber Diameter
125 μm
Coating Diameter
250-900 μm
Cleave Length
Single 5mm-20mm,Ribbon 10mm
Blade Life time
50,000
Outfit Dimension
58 x 55 x 48mm
88x55x48mm
Weight
340g
400g
“The new era of telecommunication”
www.erattelekom.com.tr
101
SWIFT CLEAVER TYPES
Cleavers
Swift CI-06
Technical Specification
Fiber Diameter
90° ± 0.5°
Cleave Life
2,000
Size
19x32x124mm
Weight
70g
Swift CI-08 Angled Cleaver
PCT/KR2007/002695
3M USE
Key Features
Single Action for Cleaving & Fiber Chip Collection
Oil Damper System
High Precision Blade with 16 Cleave Spots
Diamond Blade with 1 Million Cleave Life (Option)
Blade BI-05
Technical Specification
102
Fiber Diameter
125μm
Coating Diameter
250-900μm
Cleave Angle
6° - 9°
Blade Life time
Max. 30,000
Outfit Dimension
104x72x56mm
Weight
400g
“The new era of telecommunication”
www.erattelekom.com.tr
Angle Cleaved Fiber
Cleaved End Facet
FIBER CLEAVER BLADES
AND SPLICER ELECTRODES
Cleaver Blades & Electrodes
Cleaver Blades
BI-05
BI-01
BI-02
BI-03
Splicer Electrodes
Applications
ILSINTECH manufactures compatible fiber cleaver blades and fusion splicer electrodes with high
precision processing technologies with highly durable materials.
With long lifetime and protective packging meet the specific requirements from companent manufacturing facilities on fiber splicing players throughout the industry.
ILSINTECH is open to better way of deal for blades and electrodes.
“The new era of telecommunication”
www.erattelekom.com.tr
103
Fiber Holders
Fiber Optic Closures
Holders
Applications
Fiber order line is fully compatible with all fusion splicer with 16 & 12mm sizes. Fiber holders supply
the convenient solution for fiber pirep proccess.
Features
Compatibility with fusion splicer
(Size 16m & 12m)
Multipack
CI - 03M Mass3 Fiber Cleaver
ITS-12 Thermal Stripper
IFC-24 Ultrasonic Cleaner
Single Fiber : 0.25mm, 0.4mm, 0.9mm
Multi Fiber : 2,4,6,8,10,12 Ribbon
Multipack
Series
CI - 03M
Cleaver
ITS-12 Thermal
Stripter
IFC-24 Ultrasonic
Cleaner
VGI-01: 0.250 - 0.250 Fiber
VGI-02: 0.900 - 0.900 Fiber
VGI-03: 0.900 - 0.250 Fiber
Outfit Dimesion: 50 x 50 x 50 (mm)
Weight: 350gr
104
“The new era of telecommunication”
www.erattelekom.com.tr
Date:...../...../........
“The new era of telecommunication”
www.erattelekom.com.tr
105
106
“The new era of telecommunication”
www.erattelekom.com.tr
FIBER OPTIC TEST & MEASUREMENT DEVICES
E
H
T
W
E
N
A
R
E
F
O
N
O
I
T
A
IC
N
U
M
M
O
C
E
L
E
T
ONLY
FIBER OPTIC TEST & MEASUREMENT DEVICES
“The new era of telecommunication”
www.erattelekom.com.tr
107
JDSU MTS-2000
Test & Measurement Devices
Features
Large 5-inch touch screen display
Field-installable modules
Wide range of OTDR modules,including
Quad and PON
FiberComplete automated IL/ORL,
PON power meter, and CWDM analyzer
Automated fiber inspection and IEC
pass/fail analysis
Optional built-in optical power
meter, visual fault locator (VFL),
and optical talk set
New-generation Lithium Polymer
(LiPo) battery for 8 hours operation
Flexible connectivity with
Ethernet, USB, Bluetooth and WiFi
capabilities
Special hands-free bag as standard
Benefits
Certify fiber physical layer on FTTx/PON, Access, Metro and Enterprise networks.
Ensure highest quality connectorizing, splicing and turnup of new fiber links.
Improve workflow with hands-free solution driving best practices to IEC standards.
Smarter and faster field testing with simple setup and instantaneous pass/fail results.
Boost productivity with improved report generation and
flexible connectivity.
108
“The new era of telecommunication”
www.erattelekom.com.tr
JDSU MTS-2000
Test & Measurement Devices
SPECIFICATIONS
General (Typical at 25°C)
Built-in Power Meter Specifications(1)
Display
Calibrated wavelengths
5-inch TFT color touch screen (12.5cm)
Resolution 800 x 480 WVGA
Interfaces
Two USB2.0 ports
One mini-USB2.0 port
RJ-45 LAN 10/100/1000Mbps
Built-in Bluetooth (optional)
Built-in WiFi 802.11 b/g/n (optional)
Internal memory
Battery
1GB (128MB for storage)
Rechargeable Lithium-Polymer battery
8 hours of operation as per Telcordia GR-196-CORE
Power supply
AC/DC adapter, input 100-250 VAC,
50-60Hz; 2.5A max, output 12VDC, 25W
Electrical safety: EN60950-compliant
Size with module (H x W x D)
Weight
with battery
with battery and LM OTDR
Temperature
175 x 138 x 80mm
(6.9 x 5.4 x 3.2in)
0.864 kg (1.89 lbs)
1.21 kg (2.67 lbs)
Wavelength range
850/1310/1490/1550/ 1625/1650
800 to 1650 nm in 1 nm steps
Accuracy(2)
±0.2 dB
Measurement range(3)
+5 to −50 dBm
Maximum resolution
Connector type
0.01 dB/0.01nW
Universal Push Pull (UPP)
Built-in Visual Fault Locator VFL
Wavelength
650 nm
Emission mode
CW, 1Hz
Laser class
Class 2 as per standards EN60825-1
and FDA21 CFR Part 1040.10
Built-in Talk Set
Dynamic range
Connector types
32dB (typical)
SC, FC, and UPP
(three adapters included)
Operating: -20 to +50°C (-4 to 122°F)
Storage: -20 to +60°C (-4 to 140°F)
Humidity non-condensing
95%
“The new era of telecommunication”
www.erattelekom.com.tr
109
JDSU MTS-4000
Test & Measurement Devices
Features
Cost-effective, dual-modular and handheld platform
Large 7-inch display (touchscreen option)
Comprehensive connection checker functionality with
built-in VFL, power meter, and scope
Flexible connectivity including USB, high-speed 1G
Ethernet,WiFi, and Bluetooth interfaces
Automated test and data reporting capability
Integrated web browser
Applications
Qualify Access/FTTx networks
Troubleshoot fiber- and copperbased networks
Test and turn up of passive optical (PON) or point-to-point optical networks
Test and turn up triple-play services, including IPTV and VoIP measurements from DSL access
interfaces or standard Ethernet port
110
“The new era of telecommunication”
www.erattelekom.com.tr
JDSU MTS-4000
T-BERD/MTS-4000 Technical
Environmental Specifications
Specifications (Typical 25°C)
Operating temperature range
(no option)
–20 to +50°C
(–4 to 122°F)
Display
TFT color, 7-in, LCD 800 x 480, high visibility for outdoors
Operating temperature range
(all options)
0 to +40°C
(32 to 104°F)
Touchscreen,TFT color, 7-in, LCD 800 x 480, high visibility
for outdoors
Storage temperature range
–20 to +60°C
(–4 to 140°F)
Storage and I/O Interfaces
Internal memory
Humidity, non-condensing
95%
32MB (1000 test results)
Extended memory (optional)
Minimum 1 GB (optional)
2x USB2.0, 1x RJ45 Ethernet (up to 1 Gb/s)
WiFi
Standard IEEE 802.11 b/g
Bluetooth
Class 2, up to 10 m range
Audio interface
Ethernet
2.5 mm jack connector
10/100/1000 MHz full-half duplex
Power Supply
Battery type
Standard removable Li-Ion batteries
AC/DC adapter
Input 100-250 V, 50-60 Hz
Output 12-15V DC/3.7 A
Electrical safety
EN 60950 Compliant
Operation time
Up to 11 hours with standard display
Telcordia GR-196-CORE
Size and Weight
Mainframe with two modules and battery
(W x H x D)
260 x 135 x 90 mm
(10.2 x 5.3 x 3.5 in)
Mainframe only (with battery)
Base Unit Optical Interfaces (optional)
Power Meter
Power level
+10 to –60 dBm
Wavelength
650 nm
Calibrated wavelengths
Connector type
Test & Measurement Devices
SPECIFICATIONS
850, 1310, and 1550 nm
Universal push/pull (UPP)
Visual Fault Locator (VFL)
Wavelength
635 nm ±15 nm
Output power level
<1 mW
Laser safety
Class 2 laser
Connector type
Universal push/pull (UPP)
Quick Capture Probe Kit (via USB)
Magnification
200X and 400X
Interface
Tips
through the USB port
FC, SC, SC-APC, LC, U25, U25MA, U12
1.4 kg (3 lb)
Mainframe with one module (with battery) <2 kg (<4.35 lb)
7 inch High-Visibility TFT Color Screen
– Indoor/Outdoor
– Touchscreen Configurable
Testing Indicator
6 Soft Keys
– Context-Sensitive
Microphone
Home Key
Start/Stop Key
Numerical Keypad
– Number and Text Edition
– Menu/Sub-Menu Shortcuts
Navigation Key Pad
5 Direct Access Keys
– Easy Page Selection
– No Pop-up Menus
AC/DC Power Supply and
Battery Charge Indicators
Protective Molded
Bumpers
Size (H x W x D):
Weight:
13.5 x 26 x 9 cm
5.3 x 10.2 x 3.5 inch
1.4 kg/3 lb
“The new era of telecommunication”
www.erattelekom.com.tr
111
JDSU MTS-6000
Test & Measurement Devices
Features
Lightweight platform: only 2.4kg/5.3 lbs
Large 8.4 inch transreflective TFT color display improves viewing under any conditions.
Intuitive graphical user interface with touchscreen option
Extended battery life using smart Lithium ion cell.
Connection Check with VFL, power meter, Loss Test Set/ ORL meter and video inspection scope
options
Built-in optical talkset option for communicating along the fiber.
Unique automatic bi-directional analysis function available to save up to 50% test time for OTDR,
IL, and ORL measurements.
Fast data transfer via USB, Ethernet port and 1Gb extended memory option.
Comprehensive suite of PC software tools for post-processing of test results with FiberTrace
(OFS-100) and FiberCable (OFS-200).
Applications
Fault Locator.
OTDR and power level testing.
CWDM/DWDM testing.
PMD, Spectral Attenuation Profile and Chromatic Dispersion (CD) testing.
Insertion Loss (IL) and Optical Return Loss (ORL) testing.
FiberComplete™ automated bi-directional OTDR, Insertion Loss and ORL testing.
112
“The new era of telecommunication”
www.erattelekom.com.tr
JDSU MTS-6000
Test & Measurement Devices
Highlights
Compact and lightweight for the field.
Future proof with over 40 application modules already supported.
Choose from IL/ORL, OTDR, PMD, CD, or WDM plug-in modules.
Application modules compatible with MTS-8000.
Backwards compatibility with existing MTS-5000 family OTDR modules.
Simple for the novice, fully featured for the expert.
SPECIFICATIONS
Specifications for Typical 25°C
Environmental Specifications
Display
TFT color, 8.4 in LCD, 800 x 600, high-visibility (standard)
Touchscreen,TFT color, 8.4 in LCD, 800 x 600, high-visibility
(optional)
Storage and I/O Interfaces
Internal memory
1000 test results
Operating temperature range on mains (no options)
–20 to +50°C
(–4 to 122°F)
Operating temperature range (all options) 0 to
+40°C(32 to 104°F)
Storage temperature range
–20 to +60°C
(–4 to 140°F)
2x USB V1.1, 1x RJ45 Ethernet
Power Supply
Battery type
Standard removable Li-ion batteries
Humidity, non-condensing
95%
AC/DC adapter
Input 100–240 V, 50–60 Hz,
Output 19 V DC/3.1 A
Power Meter
Power level
Operation time
Up to 11 hrs with standard display,
Telcordia GR-196-CORE
Extended memory (optional)
Bluetooth
Minimum 1 GB (optional)
Class 2, up to 10 m range
Size and Weight
Mainframe with one plug-in module
and battery (L x H x W)
285 x 195 x 93 mm
(11.2 x 7.7 x 3.7 in)
Base Unit Optical Interfaces (optional)
Calibrated wavelengths
Universal push/pull (UPP)
Connector type
Universal push/pull (UPP)
Dynamic range
45 dB
Output power level
Function
Power Supply
Battery type
Laser safety
Mainframe (with one plug-in module
and battery)
3.4 kg (7.5 lb)
Continuous Wave Light Source
Wavelengths (selection)
1310, 1550, and 1625 nm
Size and Weight
Mainframe with two modules and battery
(W x H x D)
260 x 135 x 90 mm
(10.2 x 5.3 x 3.5 in)
Mainframe only (with battery)
1.4 kg (3 lb)
Mainframe with one module (with battery) <2 kg (<4.35 lb)
Output power level
–3.5 dBm
Stability in 15 min
± 0.02 dB
Stability in 8 hrs
Laser safety
Connector type
850, 1310, and 1550 nm
Connector type
Talkset
Wavelength
Mainframe only (without battery and module) 2.4 kg (5.3lb)
Standard removable Li-Ion batteries
+10 to –60 dBm
Connector type
Optical Return Loss
Selectable wavelength
Measurement range
Measurement uncertainty
Display resolution
1550 nm ±20 nm
<1 mW
With data/file transfer
Class 1M laser
Field interchangeable
1310 / 1550 nm
0 dB to 45 dB
± 1 dB
0.01 dB
Visual Fault Locator
Wavelength
635 nm ±15 nm
Output power level
<1 mW
Laser safety
Connector type
Class 2 laser
Universal push/pull (UPP)
± 0.2 dB
Class 1M laser
Field interchangeable
Video Inspection Scope (via USB)
Magnification
250X and 400X, through the USB port
“The new era of telecommunication”
www.erattelekom.com.tr
113
JDSU POWER METER
Test & Measurement Devices
Applications
Features
Optical power level and link insertion
loss measurements
Enterprise / LAN networks • with
850/1300 nm multimode wavelengths capability
Access and metro (LAN/WAN) • networks with multimode and singlemode testing combination.
Standard and high power level • testing for any telecom, CATV and military applications.
Cost-effective, rugged and high performance
solution•
3 year recalibration period•
Universal wavelength setting in 1 nm steps•
Universal optical interface supports all 2.5
mm and • 1.25 mm connectors
Auto λ detection and TwinTest mode•
Internal data storage and optional PC download • capability
Technical Specifications
114
OLP-34
OLP-35
OLP-38
Detector type
Germanium
InGaAs
Filtered InGaAs
Optical interface / connectors
Universal 2.5 mm / 1.25
mm 1
Universal 2.5 mm / 1.25 mm 1
Wavelength range
780 to 1600 nm
780 to 1650 nm
Wavelength settings
780 to 1600 nm, step size
1 nm
780 to 1650 nm, step size 1 nm
Programmable wavelengths
5 presets (customized)
5 presets (customized)
5 presets (customized)
Calibrated wavelengths
850, 980, 1300, 1310,
1490, 1550 nm
850, 980, 1300, 1310,
1490, 1550, 1625 nm
850, 980, 1300, 1310,
1490, 1550, 1625 nm
Power Range
1490, 1550 nm
-65 to +10 dBm
-50 to +26 dBm
Display range
-60 to +10 dBm
-65 to +13 dBm
-50 to +26 dBm
Max. input power
+13 dBm
+16 dBm
+27 dBm
Measurement units
dB / dBm / W
dB / dBm / W
dB / dBm / W
Absolute uncertainty 2
± 0.2 dB (± 5%)
± 0.2 dB (± 5%)
± 0.2 dB (± 5%)
Linearity 3
2± 0.06 dB (-50 to +5 dBm)
± 0.06 dB (-50 to +5 dBm)
± 0.06 dB (-32 to +20 dBm)
Tone detection
270 Hz, 1 kHz, 2 kHz
270 Hz, 1 kHz, 2 kHz
270 Hz, 1 kHz, 2 kHz
Auto λ mode 4
Yes
Yes
Yes
Multi λ mode 4
TwinTest / serial TripleTest
TwinTest / serial TripleTest
TwinTest / serial TripleTest
“The new era of telecommunication”
www.erattelekom.com.tr
Universal 2.5 mm / 1.25 mm 1
780 to 1650 nm
780 to 1650 nm, step size 1 nm
JDSU LIGHT SOURCE
Test & Measurement Devices
Applications
Features
Link insertion loss measurements and continuity
check
Enterprise / LAN networks with 850/1300 nm multimode wavelengths capability
Access and metro (LAN/WAN) networks with multimode and singlemode testing combination.
Standard singlemode wavelengths for any telecom,
CATV and military applications.
Cost-effective, rugged and high performance
solution
Interchangeable connectors for maximum
flexibility
Auto λ and TwinTest transmission modes
3 year calibration
Combines up to 4 wavelengths in one instrument (SM+MM)
Technical Specifications
OLS-34
OLS-35
Multimode Light Source Singlemode Light Source
OLS-36
Quad Light Source
Source Type
LED
Laser
LED/Laser
Fiber type
MM (50/125 μm)
SM (9/125 μm)
MM (50/125 μm)/SM (9/125
μm)
Optical interface type
PC /
1 single port for all wavelengths
PC/
1 single port for all wavelengths
PC/
1 port for MM and 1 port for
SM
Optical interface connectors
Fixed: ST, FC, SC
Fixed: LC, FC, SC
Interchangeable LC, FC, SC,
Interchangeable LC, FC, SC, ST, DIN
ST, DIN
Fixed: LC, FC, SC
Interchangeable: LC, FC, SC,
ST, DIN
Central Wavelength
850 nm (± 20 nm)
1300 nm (± 20 nm)
1310 nm (± 20 nm)
1550 nm (± 20 nm)
850 (± 20 nm)1300 (± 20 nm)
1310 (± 20 nm)1550 (± 20 nm)
Spectral width 1
<170 nm
<5 nm
<170 nm/<5 nm
Output power
- 20 dBm 2
- 7 dBm
-20 dBm/ -7 dBm
Stability short term (15 min)3
± 0.02 dB
0.02 dB
± 0.02 dB
Stability long term (8h) 3
± 0.05 dB
0.05 dB
± 0.05 dB
Tone generation
270 Hz, 1 kHz, 2 kHz
270 Hz, 1 kHz, 2 kHz
270 Hz, 1 kHz, 2 kHz
Auto λ mode4
Yes
Yes
Yes
Multi λ mode4
Yes (2 λs)
Yes (2 λs)
Yes (4 λs)
CPR capability for MM
launch conditions
CPR capability for MM launch
conditions
“The new era of telecommunication”
www.erattelekom.com.tr
115
Visual Fault Locators
Test & Measurement Devices
Optical Fiber Damage/Break Locator
FFL-100
(Ruggedized)
FFL-050
(Pocket-sized)
Features
Applications
Compact, ergonomic design for ultimate portability
Visible wavelength is 650 nm
High powered laser (1 mW) for single-mode (> 7 km)
and multi-mode (> 5 km) connectors
Universal connector interface for quick and easy connection
2.5 mm connector input (1.25 mm adapter available)
Locate sharp bends, breaks, and
damages in fiber
Conduct end-to-end continuity tests
Perform fiber tracing and
identification
Includes soft-sided carrying case with belt loop
Specifications
FFL-050 (Pocket-sized)
116
FFL-100 (Ruggedized)
Dimensions
11.4 x 3.5 x 2.0 cm
(4.5 x 1.4 x 0.8 in)
22.0 x 3.5 x 3.0 cm
(8.7 x 1.4 x 1.2 in)
Weight
46 g (1.6 oz) with two AAA batteries
150 g (5.3 oz) with two AA batteries
Fiber Compatibility
Single-mode, Multimode
Single-mode, Multimode
Wavelength
650 nm (visible)
650 nm (visible)
Laser Safety Rating
Class II
Class II
Output Power
1.0 mW max
1.0 mW max
Output Modes
Continuous and flashing
Continuous and flashing
Range
> 7 km single-mode
> 5 km multimode
> 7 km single-mode
> 5 km multimode
Connector Interface
Universal 2.5 mm (fixed)
Universal 1.25 mm adapter
(sold separately)
Universal 2.5 mm (fixed)
Universal 1.25 mm adapter
(included)
Controls
ON/OFF
Continuous/Flashing
ON/OFF
Continuous/Flashing
Battery Type
Two AAA
Two AA
Battery Life
30+ hours on continuous
80+ hours on continuous
Carrying Case
Soft-sided with belt loop
Soft-sided with belt loop
Safety
1992, EN 61010-2, CE
1992, EN 61010-2, CE
Warranty
1 year
1 year
“The new era of telecommunication”
www.erattelekom.com.tr
Next-Generation Cable Certifier
Features
Improve installer productivity up to 50 percent by
eliminating unnecessary walking between local
and remote units, with a Touch2 system that lets
them view and analyze test result at bots ends.
Protect your investment with the most advanced
tester in the market that certifies beyond TIA-568/
ISO 11801 standards, with a 1600 MHz measurement frequency.
Quickly increase the productivity of new and
experienced installers using the revolutionary
large touch screen with intuitive user interface
Test & Measurement Devices
Certifier 40G
Benefits
Revolutionary large touch screen
Touch2 two-ended control
Reduces time walking back and forth
Future proof 1600MHz testing
Fastest CAT 6A/Class FA test
Level IV accuracy over the full Class FA spectrum
Integrated planning software
Optional integrated fiber end face inspection
Specifications
Dimensions
Environmental
Size
232x126x86.7mm
(9.13x4.96x3.41 in)
Operating
temperature
Weight
approx. 1.4kg (3.0lb)
per unit
Connectivity
Probe interface connector
Ordering Information
0 to 40 C
NGC-4500-FA
(NA/EU/UK/AU)
Certifier 40G Class FA copper kit (class FA adapters not included) with NA power cord
Storage
temperature
-20to 60 C
NGC-4500
-6ACH2
Certifier 40G CAT6A channel adapter pair
Relative
temperature
10 to 80 %
NGC-4500
-6ALKIT2
Certifier 40G CAT6A permanent link testing kit
NGC-4500
-TERACH2
Certifier 40G CLASS FA TERA channel
adapter pair
Memory
RJ45 Ethernet port
More than 500MB of internal
flash memory
NGC-4500
-TERAL2
Certifier 40G CLASS FA TERA permanent link
testing kit
USB host and device interface
1GB USB Flash Drive included
for flexible test recor storage
NGC-4500
-GGARJCH2
Certifier 40G CLASS FA GG45/ARJ45
channel adapter pair
Talk set interface: 3.5mm
stereo jack
“The new era of telecommunication”
www.erattelekom.com.tr
117
Live Fiber Identifier With
Integrated Optical Power Meter
Test & Measurement Devices
FI-60
Features
SafeChek easy-pull trigger system ensures
repeatable engagement with fiber cable
Durable metal input adapters (2.5 and
1.25mm) for OPM
Measure both absolute (dBm) and relative
(dB) power
Store and recall up to 100 OPM readings
Easily detect the optical signal without having to
disconnect the fiber
Installation, service, maintenance, or
troubleshooting
Integrate with FiberChek2 for combined inspection
and test reporting.
Live Fiber
Identifier
Optical
Pwer Mater
Specifications
Genaral
LFI
OPM
Dimensions
216x60x38 mm
(8.5x2.35x1.5 in)
171x42x25mm
(6.8x1.7x1.4 in)
780 to 1800nm
Weight
135g (4.8 oz) with two
Weight
AA alkaline batteries
100g(3.5oz) with two AA
alkaline batteries
Battery Life
70 hours
Detection
sensitivity
-20 dBm @1310 nm
-30 dBm @ 1550 nm
Connector
input
1.25mm and 2.5mm available
USB type
2.0
İnsertion loss
(typical)
1310 nm: <2dB
1550 nm: <2dB
Measurement
types
dB , dBm
Screen Size(WxH)
3.7 x 3.1 cm
Detected
wavelengths
850 to 1700 nm
Detected optical
power range
-65dB to +10dBm
Storage
temperature
-20 to 70 C
Detected
tones
270Hz, 330Hz,
1kHz, 2kHz
Max. permitted
input level
+23 dBm
Operating
temperature
0 to 50 C
Standard cable
diameter range
250 μm-3mm
İntrinsic uncertainty1- Linearity1
± 0.20 dB (± 5%)
± 0.06 dB (-5dBm to +5dBm)
Power Source
2 x AA Alkaline
Batteries
Wavelength Range
Dimensions
Standard
85,980,1300,1310,
wavelength settings 1490,1550,1625nm
118
“The new era of telecommunication”
www.erattelekom.com.tr
Bare Fiber Optic OTDR Patch Cord
Bare Fiber Optic OTDR Test Patch Cord -SM with FC/PC is the standard singlemode unit (9/125 μm fiber)
and has approx. 1.4 meters of cable. SM Connector options include FC and SC. PC and APC Types are
avaiable.
Bare Fiber Optic OTDR Test Patch Cord -MM (the multimode unit) is avaible with 62.5/125 μm or 50/125
μm GI fiber and has approx. 1.4 meters of cable. Multimode connectornoptions include FC and ST:
A cable leght of approx. 3 meters is optionally avaible for all singlemode and multimode units.
Applications
Bare Fiber Optic OTDR Test Patch Cord (also known as Multipurpose Pigtail) is an excellent tool for connecting to bare fibers for the measurements of the characteristics of optical fibers. It is designed for SM
or granded index (GI) bare fiber and can be connected easily and quickly. Importantly, Its typical insertion loss is less than 0.3 dB. Applications include connecting bare fibers to OTDR equipment, chromatic
dispersion test sets, sources, detectors, transmitters,receivers, power meters, and fiber phones (for example for communicating during the installation of fiber cable. The OTDR Test Patch Cord can be used
in labs, factories and outdoor installations.
Bare Fiber Optic OTDR Patch Cord
Features
Specifications
Fiber Diameter
125 +/-2 μm
Insertion Loss
Typically <0.3 dB
Aligment Time
Approx. 1 sec.
Number of Insertions
> 10,000
Reflection Loss
Typically >50 dB
Operating Temperature Range
-10°C to 50°C
“The new era of telecommunication”
www.erattelekom.com.tr
119
OTDR Launch Cable Box
OTDR Launch Cable Box
Designed to aid in the testing of fiber optic cable when using an OTDR. The OTDR
Launch Fiber box is used with Optical Time Domain Reflectometers (OTDR's) to
help minimize the effects of the OTDR's launch pulse on measurement uncertainty.
Available in many different configurations and fiber lengths.
Product Appearance
Outside View
Inside View
120
“The new era of telecommunication”
www.erattelekom.com.tr
OTDR Launch Cable Box
Pulse Suppressor, Launch Box, Delay Line, Installation/Testing, Training, Calibration
Compound Latch for positive seal and easy opening with locking feature
Non-metal construction will not dent, corrode, or conduce electricity
Water and dust prove allowing the unit to be taken into almosta ny environment
OTDR Launch Cable Box
Features
Case can house up to 2,000 meters of fiber
Auto Purge Valve for changes in altitude and temperature
Specifications
Length x Width x Height
9.37" x 5.56" x 2.62"
Material
SR Polypropylene
Color
Black/Yellow
Weight
0.75 kg (without fiber)
Operating temperature
-40° to +55°C
Typical Loss
< 1dB @ 1310nm for 1000 meters
Ordering Choice
LB-[A]-[B]-[C]-[D]
A = Input
connector
B = Output
connector
C = Fiber
D = Length
(km)
FC
FC
S –S ingle mode fiber
ST
ST
M6 – Multi mode fiber (62.5/125)
SC
SC
M5 – Multi mode fiber (50/125)
FCA –F C/APC
FCA –F C/APC
OM3
SCA – SC/APC
SCA – SC/APC
G.657A
D4
D4
LC
LC
MU
MU
Other special items are available upon request.
For example:
1km Single mode, FC on I/P lead, FC/APC on O/P lead
LB-FC-FCA-S-1km
“The new era of telecommunication”
www.erattelekom.com.tr
121
122
“The new era of telecommunication”
www.erattelekom.com.tr
OTHER PRODUCTS
E
H
T
W
E
N
A
R
E
F
O
N
O
I
T
A
IC
N
U
M
M
O
C
E
L
E
T
ONLY
OTHER PRODUCTS
“The new era of telecommunication”
www.erattelekom.com.tr
123
Fiber Optic Hand Tools Kit
Hand Tools
124
JIC - 175
Fiber Optic Stripper
JIC - 375
Fiber Optic Triad Stripper
JIC - 1022 Strip & Cutting Pliers
ES - 1964 Kewlar Scissor
UST 500 Cable Stripper
VISUAL FAULT LOCATOR
BUFFER CUTTER
“The new era of telecommunication”
www.erattelekom.com.tr
Proffessional Tool Kit
Tool Kits
1
2
Including Tool List
Name
Count
Name
Count
Name
Count
Count
Tool Kit
1
Tube Stripper
1
Kevlar Scissors
1
Permanent Pen 3
Colors
Heat Gun HL
1910 E
1
Flat Scredriver Medium Size
1
33 Pieces Allen Set
1
Torch
1
Reduction Head
14mm - 070717
1
Flat Screwdriver
Small Size
1
Diagonal Plies
28-160mm
1
Measuring Tape
5.0mm 19mm
1
Steel Tape
Dispencer 25mm
1
Phillips Screwdriver
Medium Size
1
Needle Pliers
15-160mm
1
Laser Meter
1
Cable Cleaver
1
Phillips Screwdriver
Small Size
1
Metal Utility Knife
18mm
1
Protective Gloves
1
Adjustable Pliers 60180mm
1
Orbitarary Cable Cleaver for Copper and Aliminium
47-180mm
1
Hack Saw 16 TND
1
1
“The new era of telecommunication”
www.erattelekom.com.tr
125
Fiber Optic Cleaning Kit
Fiber Optic Cleaning Kit
126
Sticklers Fiber Optic Cleaning Kit
Dust Remover
Cleaning Fluid
Wipes
Wipes Outdoor
“The new era of telecommunication”
www.erattelekom.com.tr
Clean Stixx
Date:...../...../........
“The new era of telecommunication”
www.erattelekom.com.tr
127
THE NEW ERA OF TELECOMMUNICATION
128
“The new era of telecommunication”
www.erattelekom.com.tr
DATA & LAN PATCH CORD CABLES
E
H
T
W
E
N
A
R
E
F
O
N
O
I
T
A
IC
N
U
M
M
O
C
E
L
E
T
ONLY
DATA & LAN PATCH CORD CABLES
“The new era of telecommunication”
www.erattelekom.com.tr
129
CAT 5E UTP Data Cable
Data & Lan Cables
A3
A1 Copper Conductor
A2
A2 Insulation
A1
A3 Outer Jacket
Description
HCS DataLink 100e cable series consists of 100 Ohm impedance, 4-pair and 8-pair U/UTP cables for horizontal installations in local area networks (LANs). All cables fully conform to and provide a substantial margin above all Category
5e requirements of ANSI/TIA-568-C.2 and IEC 61156-5.
Qualifications and
Approvals
Applications
1000BASE-T Gigabit Ethernet
ATM 25
ATM 155
10BASE-T Ethernet
TP-PMD
Token Ring 4 Mbps and 16 Mbps
100BASE-T “Fast Ethernet”
Broadband ve Baseband Video
100BASE-T2
ISDN Basic and Primary Access
100BASE-T4
1BASE-5 Starlan
100BASE-TX
ISALAN
Token Ring 100 Mbps
ITU V.21 and X.11
ATM 52
Category 5e according to ANSI/
TIA-568-C.2
Category 5e according to IEC
61156-5 (for ISO/IEC-11801 2nd
Edition).
100 MHz according to CENELEC
EN 50288-3
Category 5 according to ICEA
S-90-661-1997
Physical and Mechanical Properties
130
Basic Conductor
Solid, 24AWG, 0.5 mm, bare annealed copper
Insulation
Polyolefin
Number of insulated conductors
8, twisted in 4 pairs. (8 pairs in FIG-8 cables)
Color Code of Pairs
Blue x White/Blue, Orange x White/Orange, Green x White/Green, Brown x White/Brown
Overall Tape Wrap
None
Overall shield
None
Drain wire
None
Outer Jacket
LS0H Halogen free flame retardant or PVC compound
Standard Jacket Color
Light Gray RAL 7035. Other colors available upon request
Standard Surface Marking
Includes HCS P/N, cable description, Meter mark and Batch Number
Pulling force
50 N/mm2 max.
Short Term Bend Radius
8xOD mm
Long Term Bend Radius
4xOD mm
Storage Temperature
-20 to +80C
Temperature operating range
-20 to +60C
Installation temperature range
0 to +50C
Flame Test
IEC 60332-1
Halogen content in LS0H cables
Null
“The new era of telecommunication”
www.erattelekom.com.tr
CAT 5E FTP Data Cable
A1 Copper Conductor
A2 Insulation
A3
A3 Aluminium Foil
A2
Data & Lan Cables
A4
A1
A4 Copper Conductor
Description
HCS DataLink 100e cable series consists of 100 Ohm impedance, 4-pair and 8-pair F/UTP cables for horizontal installations in local area networks (LANs). All cables fully conform to and provide a substantial margin above all Category 5e requirements of ANSI/TIA-568-C.2 and IEC 61156-5.
Qualifications and
Approvals
Applications
1000BASE-T Gigabit Ethernet
ATM 155
TP-PMD
100BASE-T “Fast Ethernet”
100BASE-T2
100BASE-T4
100BASE-TX
Token Ring 100 Mbps
ATM 52
ATM 25
10BASE-T Ethernet
Token Ring 4 Mbps ve 16 Mbps
Broadband ve Baseband Video
ISDN Basic and Primary Access
1BASE-5 Starlan
ISALAN
ITU V.21 and X.11
Category 5e according to ANSI/TIA568-C.2
Category 5e according to IEC 61156-5
(for ISO/IEC-11801 2nd Edition).
100 MHz according to
50288-2
CENELEC EN
Category 5 according to ICEA S-90-6611997
Physical and Mechanical Properties
Basic Conductor
Solid, 24AWG, 0.5 mm, bare annealed copper
Insulation
Polyolefin
Number of insulated conductors
8, twisted in 4 pairs. (8 pairs in FIG-8 cables)
Color Code of Pairs
Blue x White/Blue, Orange x White/Orange, Green x White/Green, Brown x White/Brown
Overall Tape Wrap
Plastic tape, providing 100% coverage
Drain wire
24 AWG solid tin-coated copper conductor laid in close contact under the shield
Overall shield
Laminated aluminum foil (foil face in) providing 100% coverage
Outer Jacket
LS0H Halogen free flame retardant or PVC compound
Standard Jacket Color
Light Gray RAL 7035. Other colors available upon request
Standard Surface Marking
Includes HCS P/N, cable description, Meter mark and Batch Number
Pulling force
50 N/mm2 max.
Short Term Bend Radius
8xOD mm
Long Term Bend Radius
4xOD mm
Storage Temperature
-20 to +80C
Temperature operating range
-20 to +60C
Installation temperature range
0 to +50C
Flame Test
IEC 60332-1
Halogen content in LS0H cables
Null
“The new era of telecommunication”
www.erattelekom.com.tr
131
CAT 5E STP Data Cable
Data & Lan Cables
A5
A1 Copper Conductor
A4
A2 Insulation
A3
A3 Aluminium Foil
A2
A1
A4 Steel Sheath
A5 Outer Jacket
Description
HCS DataLink 100e cable series consists of 100 Ohm impedance, 4-pair and 8-pair SF/UTP cables for horizontal installations in local area networks (LANs). All cables fully conform to and provide a substantial margin above all Category 5e requirements of ANSI/TIA-568-C.2 and IEC 61156-5.
Qualifications and
Approvals
Applications
1000BASE-T Gigabit Ethernet
ATM 155
TP-PMD
100BASE-T “Fast Ethernet”
100BASE-T2
100BASE-T4
100BASE-TX
Token Ring 100 Mbps
ATM 52
ATM 25
Category 5e according to ANSI/
Token Ring 4 Mbps ve 16 Mbps
Category 5e according to IEC
ISDN Basic and Primary Access
Edition).
ISALAN
EN 50288-2
10BASE-T Ethernet
TIA-568-C.2
Broadband ve Baseband Video
61156-5 (for ISO/IEC-11801 2nd
1BASE-5 Starlan
100 MHz according to CENELEC
ITU V.21 and X.11
Category 5 according to ICEA
S-90-661-1997
Physical and Mechanical Properties
132
Basic Conductor
Solid, 24AWG, 0.5 mm, bare annealed copper
Insulation
Polyolefin
Number of insulated conductors
8, twisted in 4 pairs. (8 pairs in FIG-8 cables)
Color Code of Pairs
Blue x White/Blue, Orange x White/Orange, Green x White/Green, Brown x White/Brown
Overall Tape Wrap
Polyester tape, providing 100% coverage.
Overall inner shield
Laminated aluminum foil (foil face outward) providing 100% coverage
Overall outer shield
Tin coated copper braid, providing 65% coverage, laid in close contact over the foil
Outer Jacket
LS0H Halogen free flame retardant or PVC compound
Standard Jacket Color
Light Gray RAL 7035. Other colors available upon request
Standard Surface Marking
Includes HCS P/N, cable description, Meter mark and Batch Number
Pulling force
50 N/mm2 max.
Short Term Bend Radius
8xOD mm
Long Term Bend Radius
4xOD mm
Storage Temperature
-20 to +80C
Temperature operating range
-20 to +60C
Flame Test
IEC 60332-1
Halogen content in LS0H cables
Null
“The new era of telecommunication”
www.erattelekom.com.tr
CAT 6 UTP Data Cable
A1 Copper Conductor
A2 Insulation
A2
Data & Lan Cables
A3
A4
A1
A3 Central Member
A4 Outer Jacket
Description
HCS DataLink 250 cable series consists of 100 Ohm impedance, 4-pair and 8-pair U/UTP cables for horizontal
installations in local area networks (LANs). All cables fully conform to and provide a substantial margin above all
Category 6 requirements of ANSI/TIA-568-C.2 and IEC 61156-5.
Qualifications and
Approvals
Applications
1000BASE-TX Gigabit Ethernet
ATM 25
Over Category 6 (TIA/EIA SP-
10BASE-T Ethernet
4657)
Token Ring 4 Mbps ve 16 Mbps
1000BASE-T Gigabit Ethernet
Broadband ve Baseband Video
ATM 155
ISDN Basic and Primary Access
TP-PMD
1BASE-5 Starlan
100BASE-T “Fast Ethernet”
ISALAN
100BASE-T2
Category 6 according to ANSI/TIA568-C.2
Category 6 according to IEC 61156-5
(for ISO/IEC-11801 2nd Edition).
250 MHz according to CENELEC EN
50288-5
ITU V.21 and X.11
100BASE-T4
Token Ring 100 Mbps
100BASE-TX
Physical and Mechanical Properties
Basic Conductor
Solid, 24AWG, 0.5 mm, bare annealed copper
Insulation
Polyolefin
Number of insulated conductors
8, twisted in 4 pairs. (8 pairs in FIG-8 cables)
Color Code of Pairs
Blue x White/Blue, Orange x White/Orange, Green x White/Green, Brown x White/Brown
Overall Tape Wrap
None
Drain wire
None
Overall shield
None
Outer Jacket
LS0H Halogen free flame retardant or PVC compound
Standard Jacket Color
Light Gray RAL 7035. Other colors available upon request
Standard Surface Marking
Includes HCS P/N, cable description, Meter mark and Batch Number
Pulling force
50 N/mm2 max.
Short Term Bend Radius
8xOD mm
Long Term Bend Radius
4xOD mm
Storage Temperature
-20 to +80C
Temperature operating range
-20 to +60C
Installation temperature range
0 to +50C
Flame Test
IEC 60332-1
Halogen content in LS0H cables
Null
“The new era of telecommunication”
www.erattelekom.com.tr
133
CAT 6 FTP Data Cable
Data & Lan Cables
A5
A1 Copper Conductor
A4
A2 Insulation
A3
A3 Central Member
A2
A1
A4 Aluminium Foil
A5 Outer Jacket
Description
HCS DataLink 250 cable series consists of 100 Ohm impedance, 4-pair and 8-pair F/UTP cables for horizontal installations in local area networks (LANs). All cables fully conform to and provide a substantial margin above all Category 6
requirements of ANSI/TIA-568-C.2 and IEC 61156-5.
Qualifications and
Approvals
Applications
1000BASE-TX Gigabit Ethernet
Over Category 6 (TIA/EIA
SP-4657)
1000BASE-T Gigabit Ethernet
ATM 155
TP-PMD
100BASE-T “Fast Ethernet”
100BASE-T2
ATM 52
Category 6 according to ANSI/
10BASE-T Ethernet
Category 6 according to IEC
Broadband and Baseband Video
Edition).
1BASE-5 Starlan
EN 50288-5
ATM 25
TIA-568-C.2
Token Ring 4 Mbps and 16 Mbps
61156-5 (for ISO/IEC-11801 2nd
ISDN Basic and Primary Access
250 MHz according to CENELEC
ISALAN
100BASE-T4
ITU V.21 and X.11
100BASE-TX
Token Ring 100 Mbps
Physical and Mechanical Properties
134
Basic Conductor
Solid, 23AWG, 0.57 mm, bare annealed copper
Insulation
Polyolefin
Number of insulated conductors
8, twisted in 4 pairs. (8 pairs in FIG-8 cables)
Color Code of Pairs
Blue x White/Blue, Orange x White/Orange, Green x White/Green, Brown x White/Brown
Overall Tape Wrap
Plastic tape, providing 100% coverage
Drain wire
24 AWG solid tin-coated copper conductor laid in close contact under the shield
Overall shield
Laminated aluminum foil (foil face in) providing 100% coverage
Outer Jacket
LS0H Halogen free flame retardant or PVC compound
Standard Jacket Color
Light Gray RAL 7035. Other colors available upon request
Standard Surface Marking
Includes HCS P/N, cable description, Meter mark and Batch Number
Pulling force
50 N/mm2 max.
Short Term Bend Radius
8xOD mm
Long Term Bend Radius
4xOD mm
Storage Temperature
-20 to +80C
Temperature operating range
-20 to +60C
Flame Test
IEC 60332-1
Halogen content in LS0H cables
Null
“The new era of telecommunication”
www.erattelekom.com.tr
CAT 6 STP Data Cable
A1 Copper Conductor
A4
A2 Insulation
A3
A3 Aluminium Foil
A2
A4 Steel Sheat
A1
Data & Lan Cables
A5
A5 Outer Jacket
Description
HCS DataLink 500A cable series consists of 100 Ohm impedance, 4-pair and 8-pair S/FTP cables for horizontal
installations in local area networks (LANs). All cables fully conform to and provide a substantial margins above all
Augmented Category 6 ScTP requirements of ANSI/TIA-568-C.2 and Category 6A of IEC 61156-5.
Qualifications and
Approvals
Applications
10GBASE-T 10 Gigabit
ATM 52
Ethernet
ATM 25
1000BASE-T Gigabit Ethernet
10BASE-T Ethernet
ATM 155
Token Ring 4 Mbps and 16 Mbps
TP-PMD
Broadband and Baseband Video
100BASE-T “Fast Ethernet”
Augmented Category 6 ScTP
according to ANSI/TIA-568-C.2.
Category 6A according to
IEC 61156-5.
ISDN Basic and Primary Access
100BASE-T2
1BASE-5 Starlan
100BASE-T4
ISALAN
100BASE-TX
ITU V.21 and X.11
Token Ring 100 Mbps
Physical and Mechanical Properties
Basic Conductor
Solid, 23AWG, 0.57 mm, bare annealed copper
Insulation
Polyolefin
Number of insulated conductors
8, twisted in 4 pairs. (8 pairs in FIG-8 cables)
Color Code of Pairs
Blue x White, Orange x White, Green x White, Brown x White
Individual pair shield
Laminated aluminum foil (foil face outward) providing 100% coverage.
Drain wire
None
Overall shield
Tin coated copper braid laid in close contact over the inner foils.
Outer Jacket
LS0H Halogen free flame retardant or PVC compound.
Standard Jacket Color
Light Gray RAL 7035. Other colors available upon request.
Standard Surface Marking
Includes HCS P/N, cable description, Meter mark and Batch Number
Pulling force
50 N/mm2 max.
Short Term Bend Radius
8xOD mm
Long Term Bend Radius
4xOD mm
Storage Temperature
-20 to +80C
Temperature operating range
-20 to +60C
Flame Test
IEC 60332-1
Halogen content in LS0H cables
Null
“The new era of telecommunication”
www.erattelekom.com.tr
135
CAT 7 STP Data Cable
Data & Lan Cables
A4
A5
A1 Copper Conductor
A3
A2
A2 Insulation
A3 Aluminium Foil
A4 Steel Sheat
A1
A5 Outer Jacket
Description
HCS DataLink 600 CAT 7 cable series consists of 100 Ohm impedance, 4-pair and 8-pair S/FTP cables for horizontal
installations in local area networks (LANs). All cables fully conform to and provide a substantial margin above all Category 7 requirements of IEC 61156-5 (Specified in ISO/IEC 11801) and are tested up to 600MHz.
Qualifications and
Approvals
Applications
Broadband Digital and Analog CATV
signals up to 600 MHz
SOHO and multiple simultaneous applications on all 4 pairs
100BASE-TX
Token Ring 100 Mbps
ATM 52
ATM 25
10GBASE-T 10 Gigabit Ethernet
10BASE-T Ethernet
1000BASE-T 1 Gigabit Ethernet
Category 7 according to IEC
61156-5 (for ISO/IEC-11801)
600 MHz according to CENELEC EN 50288-4
Token Ring 4 Mbps and 16 Mbps
ATM 155
Broadband and Baseband Video
TP-PMD
ISDN Basic and Primary Access
100BASE-T “Fast Ethernet”
1BASE-5 Starlan
100BASE-T2
ISALAN
100BASE-T4
ITU V.21 and X.11
Physical and Mechanical Properties
136
Basic Conductor
Solid, 23AWG, bare annealed copper
Insulation
Polyolefin
Number of insulated conductors
8, twisted in 4 pairs. (8 pairs in FIG-8 cables)
Color Code of Pairs
Blue x White, Orange x White, Green x White, Brown x White
Individual pair shield
Polyester-aluminum foil (foil face out), providing 100% coverage
Overall shield
Tin coated copper braid laid in close contact over the inner foils
Outer Jacket
LS0H Halogen free flame retardant or PVC compound
Standard Jacket Color
Light Gray RAL 7035. Other colors available upon request
Standard Surface Marking
Includes HCS P/N, cable description, Meter mark and Batch Number
Pulling force
50 N/mm2 max.
Short Term Bend Radius
8xOD mm
Long Term Bend Radius
4xOD mm
Storage Temperature
-20 to +60C
Operating temperature
-20 to +60C
Installation temperature
0 to +50C
Flame Test
IEC 60332-1, IEC 60332-3-24 or IEC 60332-3-25
LS0H cables gas & smoke tests
IEC 60754 (gas) & IEC 61034 (smoke)
“The new era of telecommunication”
www.erattelekom.com.tr
CAT 8 STP Data Cable
A1 Copper Conductor
A3
A2
A2 Insulation
A3 Aluminium Foil
A4 Steel Sheat
A1
Data & Lan Cables
A4
A5
A5 Outer Jacket
Description
HCS DataLink 500A cable series consists of 100 Ohm impedance, 4-pair and 8-pair S/FTP cables for horizontal
installations in local area networks (LANs). All cables fully conform to and provide a substantial margins above all
Augmented Category 6 ScTP requirements of ANSI/TIA-568-C.2 and Category 6A of IEC 61156-5.
Qualifications and
Approvals
Applications
10GBASE-T 10 Gigabit
Ethernet
1000BASE-T Gigabit Ethernet
ATM 155
TP-PMD
100BASE-T “Fast Ethernet”
100BASE-T2
100BASE-T4
100BASE-TX
Token Ring 100 Mbps
ATM 52
ATM 25
10BASE-T Ethernet
Token Ring 4 Mbps and 16 Mbps
Broadband and Baseband Video
Augmented Category 6 ScTP according
to ANSI/TIA-568-C.2.
Category 6A according to
IEC 61156-5.
ISDN Basic and Primary Access
1BASE-5 Starlan
ISALAN
ITU V.21 and X.11
Physical and Mechanical Properties
Basic Conductor
Solid, 23AWG, 0.57 mm, bare annealed copper
Insulation
Polyolefin
Number of insulated conductors
8, twisted in 4 pairs. (8 pairs in FIG-8 cables)
Color Code of Pairs
Blue x White, Orange x White, Green x White, Brown x White
Individual pair shield
Laminated aluminum foil (foil face outward) providing 100% coverage.
Drain wire
None
Overall shield
Tin coated copper braid laid in close contact over the inner foils.
Outer Jacket
LS0H Halogen free flame retardant or PVC compound.
Standard Jacket Color
Light Gray RAL 7035. Other colors available upon request.
Standard Surface Marking
Includes HCS P/N, cable description, Meter mark and Batch Number
Pulling force
50 N/mm2 max.
Short Term Bend Radius
8xOD mm
Long Term Bend Radius
4xOD mm
Storage Temperature
-20 to +80C
Temperature operating range
-20 to +60C
Flame Test
IEC 60332-1
Halogen content in LS0H cables
Null
“The new era of telecommunication”
www.erattelekom.com.tr
137
Data & Lan Patch Cord Cables
Data & Lan Patch Cord Cables
1
2
CAT 5E (UTP)
3
CAT 5E (FTP)
CAT 5E (STP)
Description
HCS DataLink 100e modular cord series consists of 100 Ohm impedance, 4-pair U/UTP terminated
cords for work area, jumper and patching in local area networks (LANs). HCS DataLink 100e modular
cords feature a unique termination method, combining strength relief injection molding into the RJ45 plug with a removable boot. This design provides the advantages of both molded and non-molded
terminations. HCS DataLink 100e modular cords exceed all ANSI/TIA-568-C.2 Category 5e and ISO/
IEC-11801 (2nd Edition) requirements and are specially designed to be backward compatible with all
Category 5 jacks.
The HCS DataLink 100e modular cords can be used with either T568A or T568B modular jacks. The
standard color is Grey RAL 7035, but they are available in 10 different jacket colors and supplied with
boots that match the color of the cord.
Qualifications and
Approvals
Applications
1000BASE-T Gigabit Ethernet
ATM 155
TP-PMD
100BASE-T “Fast Ethernet”
100BASE-T2
100BASE-T4
100BASE-TX
Token Ring 100 Mbps
ATM 52
ATM 25
10BASE-T Ethernet
Token Ring 4 Mbps and 16 Mbps
Broadband and Baseband Video
ISDN Basic and Primary Access
1BASE-5 Starlan
ISALAN
ITU V.21 and X.11
Category 5e according to ANSI/
TIA-568-C.2
Category 5e according to ISO/
IEC-11801 (2nd Edition)
Physical and Mechanical Properties
138
Basic Cable Conductor
Stranded, 24 AWG, 7x0.20 mm, bare annealed copper
Number of insulated conductors
8, twisted in 4 pairs.
Color Code of Pairs
Blue x White/Blue, Orange x White/Orange, Green x White/Green, Brown x White/Brown.
Standard Jacket and boot Color
LS0H Halogen free flame retardant or PVC compound.
Cable to plug tensile strength
9 Kgf (90N) min.
Flame Test
IEC 60332-1
“The new era of telecommunication”
www.erattelekom.com.tr
Data & Lan Patch Cord Cables
2
CAT 6 (UTP)
CAT 6 FTP
3
CAT 6 STP
Features
HCS DataLink 250 modular cord series consists of 100 Ohm impedance, 4-pair U/UTP terminated
cords for work area,jumper and patching in local area networks (LANs). HCS DataLink 250 modular
cords feature a unique termination method, combining strength relief injection molding into the
RJ-45 plug with a removable boot. This design provides the advantages of both molded and nonmolded terminations. HCS DataLink 250 modular cords exceed all ANSI/TIA-568-C.2 and ISO/IEC11801 (2nd Edition) HCS 6 requirements and are specially designed to be backward compatible with
all Category 5 and Category 5e jacks.The HCS DataLink 250 modular cords can be used with either
T568A or T568B modular jacks.The standard color is Grey RAL 7035,but they are available in 10 different jacket colors and supplied with boots that match the color of the cord.
Data & Lan Patch Cord Cables
1
Qualifications and
Approvals
Applications
1000BASE-TX Gigabit Ethernet
Over Category 6 TIA/EIA-854
1000BASE-T Gigabit Ethernet
ATM 155
TP-PMD
100BASE-T “Fast Ethernet”
100BASE-T2
100BASE-T4
100BASE-TX
Token Ring 100 Mbps
ATM 52
ATM 25
10BASE-T Ethernet
Token Ring 4 Mbps and 16 Mbps
Broadband and Baseband Video
ISDN Basic and Primary Access
1BASE-5 Starlan
ISALAN
ITU V.21 and X.11
Category 6 according to
ANSI/TIA-568-C.2
Category 6 according to
ISO/IEC-11801 (2nd Edition)
Physical and Mechanical Properties
Basic Cable Conductor
Stranded, 24 AWG, 7x0.20 mm, bare annealed copper
Number of insulated conductors
8, twisted in 4 pairs.
Color Code of Pairs
Blue x White/Blue, Orange x White/Orange, Green x White/Green, Brown x White/Brown
Standard Jacket and boot Color
Light Gray RAL 7035. Other colors available upon request.
Cable to plug tensile strength
9 Kgf (90N) min.
Flame Test
IEC 60332-1
“The new era of telecommunication”
www.erattelekom.com.tr
139
Data & Lan Accessories
Data & Lan Accessories
CAT 5e UTP RJ-45 Copper Patch Panels
Applications
1000BASE-T Gigabit Ethernet
ATM 155
TP-PMD
100BASE-T “Fast Ethernet”
100BASE-T2
100BASE-T4
100BASE-TX
Token Ring 100 Mbps
ATM 52 & 25
10BASE-T Ethernet
Token Ring 4 & 16 Mbps
Broadband and Baseband
Video
ISDN
1BASE-5 Starlan
ISALAN
ITU V.21 & X.11
Qualifications and Approvals
Transmission
EMC
Safety
TIA-568-C
EN-55022, Class B (Europe)
UL94 V-0 rated plastic materials
ANSI/TIA-568-C.2
FCC Part 15, Subpart J, Class A (USA)
Zero-halogen in LS0H constructions
ISO/IEC-11801
General Properties
140
Wire size range
22 to 26 AWG, Solid or stranded (7)
Material of construction
Galvanized Steel
Paint and standard color
Black, Powder paint finish or plastic front
Connector module holder
High impact, Flame-retardant plastic compound, UL 94 V-0
Housing material - Jack & IDC
High impact FR plastic rated UL 94 V-0
Jack spring contact coating
1.27µm (50µ-Inch) hard Gold over 2.54µm (100µ-Inch) Nickel plating
Plug Retention Force
14 Kgf (140N) min
Plug to jack contact force
100 grams min.
IDC terminations cycles
200 min
IDC type
Gas tight
Plug insertion durability
750 mating cycles
Storage temperature range
-40 to +70C
Operation conditions
-20 to +60C at 0-90% RH (Non condensing)
Packaging
One unit per box
“The new era of telecommunication”
www.erattelekom.com.tr
Data & Lan Accessories
Data & Lan Accessories
CAT 5e FTP RJ-45 Copper Patch Panels
Applications
1000BASE-T Gigabit Ethernet
ATM 155
TP-PMD
100BASE-T “Fast Ethernet”
100BASE-T2
100BASE-T4
100BASE-TX
Token Ring 100 Mbps
ATM 52
ATM 25
10BASE-T Ethernet
Token Ring 4 Mbps and
16 Mbps
Broadband and Baseband Video
ISDN Basic and Primary Access
1BASE-5 Starlan
ISALAN
ITU V.21 and X.11
Qualifications and Approvals
Transmission
EMC
Safety
ANSI/TIA/EIA-568-A-5 (November 1999)
EN-55022, Class B (Europe)
UL94 V-0 rated plastic materials
ANSI/TIA-568-C.2
FCC Part 15, Subpart J, Class A (USA)
Zero-halogen in LS0H constructions
ISO/IEC-11801
General Properties
Wire size range
22 to 26 AWG, Solid or stranded (7)
Material of construction
Galvanized Steel
Paint and standard color
Black, Powder paint finish or plastic front
Connector module holder
High impact, Flame-retardant plastic compound, UL 94 V-0.
Housing material - Jack & IDC
High impact FR plastic rated UL 94 V-0.
Jack spring contact coating
1.27µm (50µ-Inch) hard Gold over 2.54µm (100µ-Inch) Nickel plating
Plug Retention Force
14 Kgf (140N) min
Plug to jack contact force
100 grams min.
IDC terminations cycles
200 min
IDC type
Gas tight
Plug insertion durability
750 mating cycles
Storage temperature range
-40 to +70C
Operation conditions
-20 to +60C at 0-90% RH (Non condensing)
Packaging
One unit per box
“The new era of telecommunication”
www.erattelekom.com.tr
141
Data & Lan Accessories
Data & Lan Accessories
CAT 6e UTP RJ-45 Copper Patch Panels
Applications
1000BASE-TX Gigabit Ethernet Over Category 6
(TIA/EIA-854-2001)
1000BASE-T Gigabit Ethernet
ATM 155
TP-PMD
100BASE-T “Fast Ethernet”
100BASE-T2
100BASE-T4
100BASE-TX
Token Ring 100 Mbps
ATM 52
ATM 25
10BASE-T Ethernet
Token Ring 4 Mbps and 16
Mbps
Broadband and Baseband Video
ISDN Basic and Primary Access
1BASE-5 Starlan
ISALAN
ITU V.21 and X.11
Token Ring 4 Mbps and
16 Mbps
Broadband ve Baseband
Video
ISDN Basic and Primary
Access
1BASE-5 Starlan
ISALAN
ITU V.21 and X.11
Qualifications and Approvals
Transmission
EMC
Safety
ANSI/TIA-568-C.1
EN-55022, Class B (Europe)
UL94 V-0 rated plastic materials
ANSI/TIA-568-C.2
FCC Part 15, Subpart J, Class A (USA)
Zero-halogen in LS0H constructions
ISO/IEC-11801
General Properties
142
Wire size range
22 to 26 AWG, Solid or stranded (7)
Material of construction
Galvanized Steel
Paint and standard color
Black, Powder paint finish or plastic front
Connector module holder
High impact, Flame-retardant plastic compound, UL 94 V-0
Housing material - Jack & IDC
High impact FR plastic rated UL 94 V-0
Jack spring contact coating
1.27µm (50µ-Inch) hard Gold over 2.54µm (100µ-Inch) Nickel plating
Plug Retention Force
14 Kgf (140N) min
Plug to jack contact force
100 grams min.
IDC terminations cycles
200 min
IDC type
Gas tight
Plug insertion durability
750 mating cycles
Storage temperature range
-40 to +70C
Operation conditions
-20 to +60C at 0-90% RH (Non condensing)
Packaging
One unit per box
“The new era of telecommunication”
www.erattelekom.com.tr
Data & Lan Accessories
Data & Lan Accessories
CAT 6e UTP RJ-45 Copper Patch Panels
Applications
1000BASE-T Gigabit Ethernet
ATM 155
TP-PMD
100BASE-T “Fast Ethernet”
100BASE-T2
100BASE-T4
100BASE-TX
Token Ring 100 Mbps
ITU V.21 and X.11
ATM 52
ATM 25
10BASE-T Ethernet
Token Ring 4 Mbps and 16
Mbps
Broadband and Baseband
Video
ISDN Basic and Primary Access
1BASE-5 Starlan
Token Ring 4 Mbps and 16 Mbps
Broadband & Baseband Video
ISDN
1BASE-5 Starlan
ISALAN
ITU V.21 and X.11
ISALAN
Qualifications and Approvals
Transmission
EMC
Safety
ANSI/TIA-568-C.1
EN-55022, Class B (Europe)
UL94 V-0 rated plastic materials
ANSI/TIA-568-C.2
FCC Part 15, Subpart J, Class A (USA)
Zero-halogen in LS0H constructions
ISO/IEC-11801
General Properties
Wire size range
22 to 24 AWG, Solid conductors.
Material of construction
CRS (Cold rolled steel), 1.5mm thickness.
Paint and standard color
Black or Grey.
Plastic parts
High impact, Flame-retardant plastic compound, UL 94 V-0.
Housing material - Jack & IDC
High impact FR plastic rated UL 94 V-0.
Jack spring contact coating
Phosphor Bronze with 50µ” hard Gold over 100µ” Nickel plating
Plug Retention Force
50N min.
Plug to jack contact force
100 grams min.
IDC terminations cycles
200 min
IDC type
Gas tight
Plug insertion durability
750 mating cycles
Storage temperature range
-40 to +70C
Operation conditions
-20 to +60C at 0-90% RH (Non condensing)
Packaging
One unit per box
“The new era of telecommunication”
www.erattelekom.com.tr
143
Data & Lan Accessories
Data & Lan Accessories
RJ-45 Keystone Jacks
CAT 5e UTP
CAT 5e UTP
CAT 5e FTP
CAT 5e FTP
CAT 6e UTP
CAT 6e UTP
CAT 6e FTP
CAT 6e FTP
General Properties
144
Housing Material
High impact, Flame-retardant plastic compound, UL 94 V-0.
Jack Contacts Material
50 micro-inches gold plating over 100 micro-inches nickel plated copper alloy.
Environmental conditions
-40 to +60C at 0-90% RH (Non condensing)
Packaging
50 or 100 Units per box.
Plug Retention Force
5 Kgf (50N) min.
Plug to jack contact force
100 gr min. (using HCS approved plug).
Storage Temperature
-20 to +80C
Plug insertion durability
750 mating cycles
Conductor compatibility range
22 to 26 AWG, solid or stranded
Standard Color
White RAL 1013. Other colors available upon request.
“The new era of telecommunication”
www.erattelekom.com.tr
Data & Lan Accessories
Data & Lan Accessories
RJ-45 Plugs
RJ-45 Plugs
5e UTP
5e UTP
Qualifications and Approvals
Transmission
EMC
Safety
ANSI/TIA-568-C.2
EN-55022, Class B (Europe)
L94 V-0 rated plastic materials
ISO/IEC-11801
FCC Part 15, Subpart J, Class A (USA)
General Properties
Plug Tolerances and Dimensions
Compliant with IEC-60603-7-2 and FCC requirements
Plug housing material
Polycarbonate, rated UL 94 V-0.
Plug contacts
Selective gold plating over nickel plated copper alloy.
Shield construction
Overall.
Shield material
Tin-plated brass
Environmental conditions
-40 to +60C at 0-90% RH (Non condensing)
Packaging
100 units per bag.
Cable to Plug Tensile Strength
9 Kgf (90N) min.
Plug to jack contact force
100 gr min. (using HCS approved jacks).
Operating Temperature
-20 to +80C
Plug insertion durability
750 mating cycles
Color
Transparent. Other colors available upon request.
“The new era of telecommunication”
www.erattelekom.com.tr
145
146
“The new era of telecommunication”
www.erattelekom.com.tr
FIBER OPTIC CABIN AND CABINETS
E
H
T
W
E
N
A
R
E
F
O
N
O
I
T
A
IC
N
U
M
M
O
C
E
L
E
T
ONLY
FIBER OPTIC CABIN AND CABINETS
“The new era of telecommunication”
www.erattelekom.com.tr
147
Fiber Optic Cabin & Cabinets
Benefits & Features
Description
HCS DataLine series includes a wide range of
high quality racks, cabinets and enclosures,
specially designed for structured premise cabling in local area networks (LANs), including distribution and equipment, cross connect cabinets and racks, splice boxes, climate
control and many more components for both
copper andfiber optic cabling systems.
HCS DataLine 21 SOHO Wall Mount Cabinets
are suitable mainly for office environments &
equipment rooms, having an attractive design combined with along-lasting, solid &
stable construction, guaranteed by the HCS
DataLine Logo & Trademark.
Solid and stable construction- providing support for large loads.
Aesthetic & attractive design - for use in open
office environments.
Flat packed design option- providing minimal storage space and saving transportation
costs.
Large cable spaces - enabling easy and comfortable installation of many cables.
Sophisticated cable channeling - enabling
concealed cords routing.
Clear u-marking inside the cabinets - enabling easy & simple profile installation planning.
Vented top cover- allows passive ventilation.
PVC stoppers - avoid metal surface noice
while side panels are mounted.
Applications
The special design of HCS DataLine 21 SOHO Wall
Mount Cabinets allows the use of a large variety and
types of accessories, including 19” panels, hubs and
grounding and potential equalization bus bars,
lighting units, stacking kits,floor fixing kits, cable
management panels, and many other 19’’ devices
and accessories.
Technical Specifications
General
Steel Sheets
Powder
Coating
Mechanical
Assembly
TS EN 60297
3-100/101/102
DIN EN
10130-91
DIN 67530
TS EN 61587-1
TS EN
60917-2-1/-2
DIN 41494
DIN EN 10327
ASTM D 2796
TS EN 60529-1
EREGLİ 6112
ASTM D 3451
IP20 (Opsiyonal IP 42)
148
“The new era of telecommunication”
www.erattelekom.com.tr
IT Equipment
Safety
Fan Unit &
Power
TS EN 60950-1
TS EN 60439-1
IEC 60364-7-707
TS EN 62208
Fiber Optic Cabin & Cabinets
Benefits & Features
Description
HCS DataLine series includes a wide range of
high quality racks, cabinets and enclosures,
specially designed for structured premise cabling in local area networks (LANs), including
distribution and equipment, cross connect
cabinets and racks, splice boxes, climate control and many more components for both copper andfiber optic cabling systems.
HCS DataLine 20 600x560 Wall Mount Cabinets are suitable mainly for office environments & equipment rooms, having an attractive design combined with along-lasting, solid
& stable construction, guaranteed by the HCS
DataLine Logo & Trademark.
Applications
The special design of HCS DataLine 20 Wall
Mount Cabinets allows the use of a large variety and types of accessories, including 19”
panels, hubs and active equipment, fixed and/
or sliding shelves, fan units, power strips,
pulleys,grounding and potential equalization
bus bars, lighting units, stacking kits,floor fixing kits, cable management panels, and many
other 19’’ devices and accessories.
Solid and stable construction- providing support for large loads.
Aesthetic & attractive design - for use in open
office environments.
Flat packed design option- providing minimal storage space and saving transportation
costs.
Large cable spaces - enabling easy and comfortable installation of many cables.
Sophisticated cable channeling - enabling
concealed cords routing.
Clear u-marking inside the cabinets - enabling easy & simple profile installation planning.
Removable side, front and rear doors - allows
using cabinet as a relay rack.
Adjustable profile positioning inside the cabinets - enabling efficient installation of different size devices.
Vented top cover- allows passive ventilation.
PVC stoppers - avoid metal surface noice
while side panels are mounted.
Pulleys and levelling fit mountable - enabling
installation as free-standing cabinets.
Technical Specifications
General
Steel Sheets
Powder
Coating
Mechanical
Assembly
TS EN 60297
3-100/101/102
DIN EN
10130-91
DIN 67530
TS EN 61587-1
TS EN
60917-2-1/-2
DIN 41494
DIN EN 10327
ASTM D 2796
TS EN 60529-1
EREGLİ 6112
ASTM D 3451
IT Equipment
Safety
Fan Unit &
Power
TS EN 60950-1
TS EN 60439-1
IEC 60364-7-707
TS EN 62208
IP20 (Opsiyonal IP 42)
“The new era of telecommunication”
www.erattelekom.com.tr
149
Free Standing Cabinets
Fiber Optic Cabin & Cabinets
Benefits & Features
Description
HCS DataLine series includes a wide range of
high quality racks, cabinets and enclosures,
specially designed for structured premise cabling in local area networks (LANs), including
distribution and equipment, cross connect
cabinets and racks, splice boxes, climate control and many more components for both copper andfiber optic cabling systems.
HCS DataLine 21 SOHO Wall Mount Cabinets
are suitable mainly for office environments &
equipment rooms, having an attractive design
combined with along-lasting, solid & stable
construction, guaranteed by the HCS DataLine
Logo & Trademark.
Applications
The special design of HCS DataLine 21 SOHO
Wall Mount Cabinets allows the use of a large
variety and types of accessories, including 19”
panels, hubs and active equipment, fixed and/
or sliding shelves, fan units, power strips, pulleys, grounding and potential equalization bus
bars, lighting units, stacking kits,floor fixing
kits, cable management panels, and many
other 19’’ devices and accessories.
Solid and stable construction- providing support for large loads.
Aesthetic & attractive design - for use in open
office environments.
Flat packed design option- providing minimal storage space and saving transportation
costs.
1000 mm depth - enabling easy and comfortable installation of many cables.
Sophisticated cable channeling - enabling
concealed cords routing.
Clear u-marking inside the cabinets - enabling easy & simple profile installation
planning.
Removable side panels via handles - enabling
fast & easy cabinet stacking.
Removable side, front and rear doors - allows
using cabinet as a relay rack.
Adjustable profile positioning inside the cabinets - enabling efficient installation of different size devices.
Adjustable cable entry - allows many cables’
entry.
Vented top cover- allows passive ventilation.
Stackable construction - allows to proper installation many cabinets side to side.
PVC stoppers - avoid metal surface noice
while side panels are mounted.
Technical Specifications
General
Steel Sheets
Powder
Coating
Mechanical
Assembly
TS EN 60297
3-100/101/102
DIN EN
10130-91
DIN 67530
TS EN 61587-1
TS EN
60917-2-1/-2
DIN 41494
DIN EN 10327
ASTM D 2796
TS EN 60529-1
EREGLİ 6112
ASTM D 3451
IP20 (Opsiyonal IP 42)
150
“The new era of telecommunication”
www.erattelekom.com.tr
IT Equipment
Safety
Fan Unit &
Power
TS EN 60950-1
TS EN 60439-1
IEC 60364-7-707
TS EN 62208
Server Standing Cabinets
Fiber Optic Cabin & Cabinets
Benefits & Features
Description
HCS DataLine series includes a wide range of
high quality racks, cabinets and enclosures,
specially designed for structured premise cabling in local area networks (LANs), including distribution and equipment, cross connect cabinets and racks, splice boxes, climate
control and many more components for both
copper and fiber optic cabling systems.
HCS DataLine 10 800x1000 Free Standing
Cabinets are suitable for both office environments & equipment rooms, having an attractive design combined with along-lasting, solid & stable construction, guaranteed by the
HCS DataLine Logo & Trademark.
Applications
The special design of HCS DataLine 10 Free Standing Cabinets allows the use of a large variety and
types of accessories, including 19” panels, hubs and
active equipment, fixed and/or sliding shelves, fan
units, power strips, pulleys,grounding and potential
equalization bus bars, lighting units, stacking kits,
floor fixing kits, cable management panels, and
many other 19” devices and accessories.
Solid and stable construction- providing support for large loads.
Aesthetic & attractive design - for use in open
office environments.
Flat packed design option- providing minimal storage space and saving transportation
costs.
1000 mm depth - enabling easy and comfortable installation of many cables.
Sophisticated cable channeling - enabling
concealed cords routing.
Clear u-marking inside the cabinets - enabling easy & simple profile installation
planning.
Removable side panels via handles - enabling
fast & easy cabinet stacking.
Removable side, front and rear doors - allows
using cabinet as a relay rack.
Adjustable profile positioning inside the cabinets - enabling efficient installation of different size devices.
Adjustable cable entry - allows many cables’
entry.
Vented top cover- allows passive ventilation.
Stackable construction - allows to proper installation many cabinets side to side.
PVC stoppers - avoid metal surface noice
while side panels are mounted.
Technical Specifications
General
Steel Sheets
Powder
Coating
Mechanical
Assembly
TS EN 60297
3-100/101/102
DIN EN
10130-91
DIN 67530
TS EN 61587-1
TS EN
60917-2-1/-2
DIN 41494
DIN EN 10327
ASTM D 2796
TS EN 60529-1
EREGLİ 6112
ASTM D 3451
IT Equipment
Safety
Fan Unit &
Power
TS EN 60950-1
TS EN 60439-1
IEC 60364-7-707
TS EN 62208
IP20 (Opsiyonal IP 42)
“The new era of telecommunication”
www.erattelekom.com.tr
151
Cabinet Accessories
Fiber Optic Cabinet Accessories
Fan Units
Shelves
Castors & Levelling Feet
and Accessories
Power Strips and Organizers
152
“The new era of telecommunication”
www.erattelekom.com.tr
Date:...../...../........
“The new era of telecommunication”
www.erattelekom.com.tr
153
fiber optic
Academy
154
“The new era of telecommunication”
www.erattelekom.com.tr
Content of Training
Mr. John Doe
always try to improve your knowledge
Introduction to Fiber Optic Cables
The Kinds of fiber Optic Cables
Preparation for Fiber Optic Project Process
The Stage of Infrastructure and Installation
Introducing and Application of Fiber optic Supplemental Devices
Introducing and Application of Fiber Optic OTDR Test Device
Using of Powermeter ( Test Kit)
Termination and Application of Fiber Optic Cable Supplementary Casette
Termination and Application of Fiber Optic Cable Patch Panel
Fiber Optic Active Devices
Examination and Certification
Training and Certificate
Content Of Education Program
www.eratakademi.com
“The new era of telecommunication”
www.erattelekom.com.tr
155
Certificates
Certificates
156
“The new era of telecommunication”
www.erattelekom.com.tr
Date:...../...../........
“The new era of telecommunication”
www.erattelekom.com.tr
157
International Standards
International Standards
158
INTERNATIONAL STANDARDS
Description
Standards Name
ASTM D 92
ASTM D 150
ASTM D 638
Test method for flash and fire points by cleveland open cup
Standard Test Methods for AC Loss Characteristics and Permittivity (Dielectric Constant) of Solid Electrical Insulation.
Standard Test Method for Tensile Properties of Plastics.
ASTM D 696
ASTM D 746
Standard Test Method for Coefficient of Linear Thermal Expansion of Plastics Between -30°C and 30°C With a Vitreous Silica Dilatometer.
Standard Test Method for Brittleness Temperature of Plastics and Elastomers by Impact.
ASTM D 792
ASTM D 885
ASTM D1169
ASTM D 1535
ASTM D 1693
Standard Test Methods for Density and Specific Gravity (Relative Density) of Plastics by Displacement.
Standard Test Methods for Tire Cords, Tire Cord Fabrics, and Industrial. Filament Yarns Made from Manufactured Organic -Base Fibers. Insulating Liquids.
Standard Test Method for Specific Resistance (Resistivity) of Electrical
Standard Practice for Specifying Color by the Munsell System.
Standard Test Method for Environmental Stress - Cracking of Ethylene Plastics.
ASTM D 3916
EIA -445
EN 187000
Standard Test Method for Tensile Properties of Pultruded Glass -Fiber - Reinforced Plastic Rod.
Fiber Optic Test Procedures (FOTPs).
European Norm: The cables have been tested to show compliance with reference to parts; 501- Max Tensile Load,504 - Crush Values, 513 - Bend, 601
FOTP -3
FOTP -4
FOTP -5
Temperature Cycling, and 605B - Water Penetration
Procedure to Measure Temperature Cycling Effects on Optical Fibers, Optical Cable, and Other Passive Fiber Optic Components.
Fiber Optic Component Temperature Life Test GR -264 -CORE Generic Requirements for Optical Fiber Cleavers.
Humidity Test Procedure for Fiber Optic Components.
FOTP - 11
FOTP -21
GR -264 -CORE
GR -326 -CORE
GR -765 -CORE
GR -1081 -CORE
GR -1221 -CORE
IEC 60332 -1-2
IEC 60332 -3
IEC 60751 -2
IEC 60793 -2-50
IEC 60794 -1-2 E1
IEC 60794 -1-2 E11
IEC 60794 -1-2 E3
IEC 60794 -1-2 E4
Vibration Test Procedure for Fiber Optic Components and Cables.
Mating Durability of Fiber Optic Interconnect ing Devices.
Generic Requirements for Optical Fiber Cleavers.
Generic Requirements for Single mode Optical Connectors and Jumper Assemblies
Optical Splices and Splicing Systems.
Generic Requirements for Field -Mountable Optical Fiber Connectors.
Generic Reli ability Assurance Requirements for Passive FO Components.
Tests on electric and optical fibre cables under fire conditions.
Flame -retardant.
Non -corrosive (FRNC).
Optical fibres: Product specifications - Sectional specification for class B. single -mode fibres.
Optical fibre cables Part 1 -2: Generic specification Basic optical cable test procedures.
Cable Bend.
Crush.
Impact.
IEC 60794 -1-2 E6
IEC 60794 -1-2 E10
Repeated Bending.
Kink.
IEC 61034
IEC 61300 -x
IEC 61300 -2-1
IEC 61300 -2-2
IEC 61300 -2-4
IEC 61300 -2-5
IEC 61300 -2-9
IEC 61300 -2-18
IEC 61300 -2-19
IEC 61300 -2-21
IEC 61300 -2-22
IEC 61300 -2-26
IEC 61300 -2-42
IEC 61300 -2-45
IEC 61300 -2-48
IEC 61300 -3-1
IEC 61300-3-2
IEC 61300 -3-3
IEC 61300 -3-4
IEC 61300 -3-6
IEC 61300 -3-7
IEC 61300 -3-20
IEC 61300 -3-28
IEC -61300-3-34
IEC 61300 -3-35
IEC 61753
IEC 61754
IEC 61754
IEC -61755
IEC 62005
ISO 527
ISO 846
ISO 1183
ISO 3146C
ISO 9001
ITU-T G.65 2
ITU-T G.657
UL 94
Low -smoke and zero -halogen (LSZH).
Fiber Optic interconnecting devices and passive components.
Vibration (Sinusoidal).
Mating durability.
Fiber/Cable retention test.
Torsion twist.
Shock.
High temperature.
Damp heat (steady state).
Composite temperature -humidity test (Z/AD).
Change of temperature.
Salt mist.
Static side load test.
Water immersion. Part 3: Examination and measurements.
Temperature cycling.
Visual examination.
Polarisation dependence of attenuation.
Monitoring change in attenuation and in return loss (multiple paths).
Attenuation.
Return loss.
Wavelength dependence of attenuation and return loss.
Directivity.
Transient loss.
Part 3 -34: Examinations and measurements -Attenuation of random mated connectors.
Part 3 -35: Examinations and measurements -Fibre optic connector endface visual and automated inspection.
Fibre optic interconnecting devices and passive components performance standard. Part 1: General and guidance for performance standards.
Fibre optic connector interfaces.
Fibre optic connector interfaces.
Fibre optic connector optical interfaces.
Reliability of Fiber Interconnecting Devices and Passive Optical Components.
Plastics - Evaluation of Tensile Properties.
Plastics - Evaluation of the action of microorganisms.
Plastics - Non - celluar plasticsa and determination of density methods.
Plastics - Melting Behaviour of Semi - Crystalline polymers (Melting Heat or Melting Range).
Quality Systems. Part 1: Specification For Design, Development, Production, Installation And Servicing.
Characteristics of a single -mode optical fibre Cable.
Characteristics of a bending loss insensitive single mode optical fibre and cable for the access network.
Tests for flammability of plastic materials for parts in devices and appliances.
“The new era of telecommunication”
www.erattelekom.com.tr
Date:...../...../........
“The new era of telecommunication”
www.erattelekom.com.tr
159
ERAT TELEKOMÜNİKASYON İNŞ. PETROL. ÜRÜN. TURİZM VE GIDA SAN. VE TİC.LTD. ŞTİ
Organize Sanayi Bölgesi 22. Cad. No:42 MELİKGAZİ/KAYSERİ /TURKEY
PHONE:
+90 (352) 322 27 70
FAX:
+90 (352) 330 40 41
Mail: [email protected]
www.erattelekom.com.tr