Advantage® Direct Vent Gas Fired Water Boiler

Advantage® Direct Vent Gas Fired Water Boiler
Advantage Direct Vent
Gas Fired Water Boiler
®
Available in heating
capacities from 52,000 to
130,000 BTU/hour.
Features
• A rugged cast iron heat
exchanger design
• Available in four sizes
• Direct vent or Power vent
• Approved for closet
applications
• Taco 0015 3-speed circulator
• ASME safety relief valve
• Supply manifold
• T&P gauge
• Flame roll out switch
• Fuel Smart HydroStat® 3200
control
- Temperature Limit Control:
Designed for cold start
boilers
- Low Water Cut-Off:
Provides protection against
potentially dangerous low
water conditions
- Boiler Reset Control:
Utilizes Thermal Targeting™
technology to conserve fuel
by monitoring heating
demand and establishing
target boiler temperatures
below the high limit setting
• Optional outdoor reset with
sensor part #48-140
• Stainless steel burners
• USA made
• Limited lifetime warranty
The PurePro® Advantage® Direct Vent
gas boiler is a residential, cast iron,
gas-fired water boiler, designed for
applications where chimneys are not
available. Advantage Direct Vent can
be direct vented (sealed combustion)
using fresh air from outside or it can
also be used in power vent applications
where combustion air is taken from the
household.
Propane and
Natural Gas
It is available with Inputs from 52,000 to
130,000 BTU/hour, and is available for
use with Natural or LP gas.
The PurePro Advantage Direct Vent
(AGDV) sets the standard for installer-ready gas fired boilers.
With its limited lifetime warranty, the Advantage Direct Vent comes standard
with intermittent ignition, a Taco 0015 3-speed circulator, and HydroStat 3200
control which combines temperature limit control, low water cut-off and boiler
reset in one easy-to-use control. This user friendly control is easily accessible,
making Advantage Direct Vent gas boiler simple to install and service.
Abundant, Rapid Hot Water Heating
PurePro offers a complete line of indirect water heaters to complement the
Advantage Oil boiler. By utilizing the Advantage Oil boiler as its heat supply, the
burner fires only when necessary and transfers heat from the Advantage boiler to
the water heater through a highly efficient heat exchanger.
Specifications
Advantage
Direct Vent Gas
Boiler Model #
Input
Mbh
Heat
Capacity
Mbh
Net AHRI
Rating, Water
Mbh
AFUE
(%)
No.
Sections
Vent Size
AL29-4C
Stainless
A
Dimension (inches)
Shipping
Weight
(Approx.)
Natural Gas Models
AGDV3-HN
60
52
45
85
3
3
W-14", H-40", D-26.5"
250
AGDV4-HN
91
78
68
85
4
3
W-16", H-40", D-26.5"
300
AGDV5-HN
121
104
90
85
5
3
W-19", H-40", D-26.5"
350
AGDV6-HN
152
130
113
85
6
3
W-22", H-40", D-26.5"
400
Propane Gas Models
AGDV3-HP
60
52
45
85
3
3
W-14", H-40", D-26.5"
250
AGDV4-HP
91
78
68
85
4
3
W-16", H-40", D-26.5"
300
AGDV5-HP
121
104
90
85
5
3
W-19", H-40", D-26.5"
350
AGDV6-HP
152
130
113
85
6
3
W-22", H-40", D-26.5"
400
Conversion Kit: Natural to LP
Mfr. #
Description
105623-01
Direct Vent Advantage Conversion Kit
Series (AGDV3 only) boilers
105430-01
Direct Vent Advantage Conversion Kit Series
(AGDV 4 through 6 only) boilers
• Specifications and dimensions are subject
to change without notice
• Approved vent pipe is 3” AL29-4C stainless
• Direct Vent or Power Vent approved
• Double wall thimble required when
penetrating a combustible wall
• Approved for combustible floor
(not carpeting) installation
• Approved for closet installation,
see O&I manual for clearances
Constructed and tested in accordance with ASME Boiler Code, Section IV.
A limited lifetime warranty is provided for the cast iron heat exchanger.
Supply and return piping connection is 1¼” – all sizes
Gas valve tapping is ½” – all sizes
LEFT SIDE VIEW
Termination fittings include:
• 3” stainless termination coupling with screen
• Galvanized air intake fitting
FRONT VIEW
A
Notes:
1. Vent pipe minimum clearance to combustible
material is four (4) inches when vent
is installed in a fully enclosed chased
application or three (3) inches when vent is
installed with at least one side open, similar
to a joist bay application.
2. Use double wall thimble when penetrating
a combustible wall.
3. 18 inch clearance required for closet
installation. 4 inch clearance required for
open installation.
4. Area of each opening, 1 sq. inch for each
1000 btuh input with a minimum of 100 sq.
inches. height of opening should be half
the width.
pureproproducts.com
PPRH40/5000/9-15
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising