Legrand XMS-5248P Quick Installation Instruction

Add to my manuals
8 Pages

advertisement

Legrand XMS-5248P Quick Installation Instruction | Manualzz

Sales

P: 801-822-5450

E: [email protected]

Technical Support

P: 801-822-5450 Option 3

E: [email protected]

Copyright and Trademark Notices

No part of this document may be modified or adapted in any way, for any purposes without permission in writing from Luxul. The material in this document is subject to change without notice. Luxul reserves the right to make changes to any product to improve reliability, function, or design. No license is granted, either expressly or by implication or otherwise under any Luxul intellectual property rights. An implied license only exists for equipment, circuits and subsystems contained in this or any Luxul product.

© Copyright 2016 Luxul. All rights reserved. The name Luxul, the Luxul logo, the Luxul logo mark and

Simply Connected are all trademarks and or registered trademarks of Luxul Wireless, Inc. All other trademarks and registered trademarks are property of their respective holders.

LUX-QIG-XMS-5248P-v3 01251710

Fold

QUICK INSTALL GUIDE

52-Port Gigabit PoE+

L2/L3 Managed Switch

XMS-5248P

Includes:

„ XMS-5248P 52-Port PoE Switch

(Includes Rack Mount Kit and Power Cord)

Fold Fold

INSTALLATION AND SETUP

1

Physical Installation

The XMS-5248P can easily be installed in a standard 19” rack. Two mounting ears are included for installing and stabilizing the switch. When attaching the mounting ears and installing the switch in a rack, please refer to the following illustration:

Rack-Mounting the XMS-5248P

„ Using the included screws to attach the mounting ears to each side of the switch.

„ Mount the switch in the rack with the LEDs facing outwards. Be sure the switch is level and properly secured in the rack.

Desktop Setup

For use as a desktop device, position and apply the included rubber feet to the bottom of the XMS-5248P.

2

Connecting Ethernet and Power

Ethernet and Power Connections

Use one of the 50 Ethernet ports to connect the XMS-5248P to any Ethernetenabled device, including servers, routers or other switches.

No crossover cable is necessary.

The XMS-5248P supports 10/100/1000 Mbps Ethernet; 10/100 Mbps half/ full-duplex mode and 1000 Mbps full-duplex mode. Ports 1-48 are PoE+ and are enabled by default. Ports 49 and 50 are Gigabit Ethernet only (non PoE).

Use the included power cable to connect the XMS-5248P to a surge- protected outlet. The AC input socket is on the rear panel. The built-in power supply supports 100~240VAC at 50/60Hz.

The rear panel also features a redundant power supply (RPS) connector. To utlize this feature, you’ll need an external power supply and an appropriate

RPS cable to connect the XMS-5248P to the external power supply.

Network Cabling

Luxul recommends Category-5, super Category-5 or Category-6 unshielded twisted pair (CAT5/CAT5e/CAT6 UTP). To ensure best performance and stable data transmission at 1000 Mbps, use Category-6 shielded twisted pair. c CAUTION: Multiple Uplink channels can create loops, resulting in network failure. Ensure only one Uplink channel exists between switches or between the XMS-5248P and a router.

n NOTE: When powering up, the port LEDs may take a moment to initialize. This is normal as the XMS-5248P initialization and startup sequence completes.

n NOTE: The XMS-5248P has an internal 740W power supply. Do not exceed 25.5W each or 740W combined consumption of all external PoE devices.

Sales

P: 801-822-5450

E: [email protected]

Technical Support

P: 801-822-5450 Option 3

E: [email protected]

Copyright and Trademark Notices

No part of this document may be modified or adapted in any way, for any purposes without permission in writing from Luxul. The material in this document is subject to change without notice. Luxul reserves the right to make changes to any product to improve reliability, function, or design. No license is granted, either expressly or by implication or otherwise under any Luxul intellectual property rights. An implied license only exists for equipment, circuits and subsystems contained in this or any Luxul product.

© Copyright 2016 Luxul. All rights reserved. The name Luxul, the Luxul logo, the Luxul logo mark and

Simply Connected are all trademarks and or registered trademarks of Luxul Wireless, Inc. All other trademarks and registered trademarks are property of their respective holders.

LUX-QIG-XMS-5248P-v3 01251710

Fold

QUICK INSTALL GUIDE

52-Port Gigabit PoE+

L2/L3 Managed Switch

XMS-5248P

Includes:

„ XMS-5248P 52-Port PoE Switch

(Includes Rack Mount Kit and Power Cord)

Fold Fold

INSTALLATION AND SETUP

1

Physical Installation

The XMS-5248P can easily be installed in a standard 19” rack. Two mounting ears are included for installing and stabilizing the switch. When attaching the mounting ears and installing the switch in a rack, please refer to the following illustration:

Rack-Mounting the XMS-5248P

„ Using the included screws to attach the mounting ears to each side of the switch.

„ Mount the switch in the rack with the LEDs facing outwards. Be sure the switch is level and properly secured in the rack.

Desktop Setup

For use as a desktop device, position and apply the included rubber feet to the bottom of the XMS-5248P.

2

Connecting Ethernet and Power

Ethernet and Power Connections

Use one of the 50 Ethernet ports to connect the XMS-5248P to any Ethernetenabled device, including servers, routers or other switches.

No crossover cable is necessary.

The XMS-5248P supports 10/100/1000 Mbps Ethernet; 10/100 Mbps half/ full-duplex mode and 1000 Mbps full-duplex mode. Ports 1-48 are PoE+ and are enabled by default. Ports 49 and 50 are Gigabit Ethernet only (non PoE).

Use the included power cable to connect the XMS-5248P to a surge- protected outlet. The AC input socket is on the rear panel. The built-in power supply supports 100~240VAC at 50/60Hz.

The rear panel also features a redundant power supply (RPS) connector. To utlize this feature, you’ll need an external power supply and an appropriate

RPS cable to connect the XMS-5248P to the external power supply.

Network Cabling

Luxul recommends Category-5, super Category-5 or Category-6 unshielded twisted pair (CAT5/CAT5e/CAT6 UTP). To ensure best performance and stable data transmission at 1000 Mbps, use Category-6 shielded twisted pair. c CAUTION: Multiple Uplink channels can create loops, resulting in network failure. Ensure only one Uplink channel exists between switches or between the XMS-5248P and a router.

n NOTE: When powering up, the port LEDs may take a moment to initialize. This is normal as the XMS-5248P initialization and startup sequence completes.

n NOTE: The XMS-5248P has an internal 740W power supply. Do not exceed 25.5W each or 740W combined consumption of all external PoE devices.

Sales

P: 801-822-5450

E: [email protected]

Technical Support

P: 801-822-5450 Option 3

E: [email protected]

Copyright and Trademark Notices

No part of this document may be modified or adapted in any way, for any purposes without permission in writing from Luxul. The material in this document is subject to change without notice. Luxul reserves the right to make changes to any product to improve reliability, function, or design. No license is granted, either expressly or by implication or otherwise under any Luxul intellectual property rights. An implied license only exists for equipment, circuits and subsystems contained in this or any Luxul product.

© Copyright 2016 Luxul. All rights reserved. The name Luxul, the Luxul logo, the Luxul logo mark and

Simply Connected are all trademarks and or registered trademarks of Luxul Wireless, Inc. All other trademarks and registered trademarks are property of their respective holders.

LUX-QIG-XMS-5248P-v3 01251710

Fold

QUICK INSTALL GUIDE

52-Port Gigabit PoE+

L2/L3 Managed Switch

XMS-5248P

Includes:

„ XMS-5248P 52-Port PoE Switch

(Includes Rack Mount Kit and Power Cord)

Fold Fold

INSTALLATION AND SETUP

1

Physical Installation

The XMS-5248P can easily be installed in a standard 19” rack. Two mounting ears are included for installing and stabilizing the switch. When attaching the mounting ears and installing the switch in a rack, please refer to the following illustration:

Rack-Mounting the XMS-5248P

„ Using the included screws to attach the mounting ears to each side of the switch.

„ Mount the switch in the rack with the LEDs facing outwards. Be sure the switch is level and properly secured in the rack.

Desktop Setup

For use as a desktop device, position and apply the included rubber feet to the bottom of the XMS-5248P.

2

Connecting Ethernet and Power

Ethernet and Power Connections

Use one of the 50 Ethernet ports to connect the XMS-5248P to any Ethernetenabled device, including servers, routers or other switches.

No crossover cable is necessary.

The XMS-5248P supports 10/100/1000 Mbps Ethernet; 10/100 Mbps half/ full-duplex mode and 1000 Mbps full-duplex mode. Ports 1-48 are PoE+ and are enabled by default. Ports 49 and 50 are Gigabit Ethernet only (non PoE).

Use the included power cable to connect the XMS-5248P to a surge- protected outlet. The AC input socket is on the rear panel. The built-in power supply supports 100~240VAC at 50/60Hz.

The rear panel also features a redundant power supply (RPS) connector. To utlize this feature, you’ll need an external power supply and an appropriate

RPS cable to connect the XMS-5248P to the external power supply.

Network Cabling

Luxul recommends Category-5, super Category-5 or Category-6 unshielded twisted pair (CAT5/CAT5e/CAT6 UTP). To ensure best performance and stable data transmission at 1000 Mbps, use Category-6 shielded twisted pair. c CAUTION: Multiple Uplink channels can create loops, resulting in network failure. Ensure only one Uplink channel exists between switches or between the XMS-5248P and a router.

n NOTE: When powering up, the port LEDs may take a moment to initialize. This is normal as the XMS-5248P initialization and startup sequence completes.

n NOTE: The XMS-5248P has an internal 740W power supply. Do not exceed 25.5W each or 740W combined consumption of all external PoE devices.

Fold Fold Fold

3

Preparing for Access

IP Addressing

If the XMS-5248P is connected to a network with a 192.168.0.X address scheme, and your computer shares a similar address on the same network, you can skip to the next step, Access and Setup.

n Note: If another device on your network shares the 192.168.0.4 address, you’ll need to temporarily reassign or remove that device while you configure the XMS-5248P.

If your network uses an address scheme other than 192.168.0.X, you’ll need to set a temporary static IP address on the computer you’re using for configuration. To do so, set the IP address of your computer to an address in the 192.168.0.X range, then set the Gateway/Router address to 192.168.0.4

(the default IP address of the XMS-5248P).

Once you’re finished configuring the switch, you can return your computer’s IP configuration to normal, typically “Obtain Automatically/DHCP.” n Note: Visit http://luxul.com/ip-addressing to learn more about changing your computer’s IP address and getting connected.

4

Access and Setup

Getting Connected

Use an Ethernet cable to connect your computer to the XMS-5248P, then power on the switch.

Logging In

To access the XMS-5248P web configuration, open your web browser and enter the switch’s default 192.168.0.4 IP address in the address field. Log in to the switch using the default user name and password:

Default IP: 192.168.0.4

Username: admin

Password: admin

Select the menu items on the left to view and/or modify the configuration.

Refer to the Quick Setup Guide at Luxul.com for more detailed information on setup, IP configuration and routing, PoE, VLANs, Spanning Tree, and Stacking.

5

Hardware Operation

Front Panel

The front panel of the XMS-5248P includes 52 Gigabit Ethernet RJ-45 ports, two

Gigabit SFP+ ports, status-, link- and PoE LEDs, a Mode/Reset button and an

RJ-45 Console port.

XMS-5248P Front Panel View

Rear Panel

The Rear Panel of the XMS-5248P features a standard AC power input and a redundant power supply (RPS) connector for use with an external power supply.

LED Indicators

The LED indicators on the XMS-5248P include System, Link/Act and PoE LEDs, and an LED for each port. These LED indicators show the operating status of the XMS-5248P and each port connection.

Mode/Reset Button to Change LED Functionality

Tapping the Mode/Reset button briefly switches the port indicator between displaying port link speed and PoE status.

The following chart shows the LED indicators of the XMS-5248P along with an explanation of the indicator’s properties:

Indicator

Name

System

Description

Port Link/

Act Status

1-50

Green Flashing Indicates normal operation.

Green On

Red On

Off

Green

Indicates a malfunction. Contact support.

Indicates power-on system initialization.

Indicates startup/initialization process or that power is not on.

1000Mbps device connected to the port.

Yellow

Flashing

Off

10/100Mbps device connected to the port.

Port receiving or transmitting data.

Nothing connected to the port.

Port PoE

Status 1-50

Green Switch is providing PoE power to a device.

Yellow

Off

PoE is off due to a fault or because the connected device is exceeding power limit.

Port disconnected or link failed.

Note: At startup, the port LEDs will flash briefly during a self-test.

Mode/Reset Button to Reset/Restore

The Reset button (located at the lower-left corner of the front panel) is used to reset (reboot) the switch, or to restore the switch to factory default settings.

X

To Reboot/Reset the Switch: With the XMS-5248P powered on, press the Reset button for approximately three seconds until the Link/Act and

PoE LEDs both light, then release the button.

c CAUTION: Do not hold the button for more than four seconds.

Doing so could erase all settings and restore factory defaults.

X

To Restore Default Settings: With the XMS-5248P powered on, press and hold the Reset button approximately eight seconds, until both the

Link/Act and PoE LEDs turn off, then release the Reset button and the switch automatically restores factory default settings and reboots. Once the System LED starts flashing again, the XMS-5248P is running with factory defaults.

c CAUTION: Please note that restoring Default Settings will remove any/all custom configuration.

Fold Fold Fold

3

Preparing for Access

IP Addressing

If the XMS-5248P is connected to a network with a 192.168.0.X address scheme, and your computer shares a similar address on the same network, you can skip to the next step, Access and Setup.

n Note: If another device on your network shares the 192.168.0.4 address, you’ll need to temporarily reassign or remove that device while you configure the XMS-5248P.

If your network uses an address scheme other than 192.168.0.X, you’ll need to set a temporary static IP address on the computer you’re using for configuration. To do so, set the IP address of your computer to an address in the 192.168.0.X range, then set the Gateway/Router address to 192.168.0.4

(the default IP address of the XMS-5248P).

Once you’re finished configuring the switch, you can return your computer’s IP configuration to normal, typically “Obtain Automatically/DHCP.” n Note: Visit http://luxul.com/ip-addressing to learn more about changing your computer’s IP address and getting connected.

4

Access and Setup

Getting Connected

Use an Ethernet cable to connect your computer to the XMS-5248P, then power on the switch.

Logging In

To access the XMS-5248P web configuration, open your web browser and enter the switch’s default 192.168.0.4 IP address in the address field. Log in to the switch using the default user name and password:

Default IP: 192.168.0.4

Username: admin

Password: admin

Select the menu items on the left to view and/or modify the configuration.

Refer to the Quick Setup Guide at Luxul.com for more detailed information on setup, IP configuration and routing, PoE, VLANs, Spanning Tree, and Stacking.

5

Hardware Operation

Front Panel

The front panel of the XMS-5248P includes 52 Gigabit Ethernet RJ-45 ports, two

Gigabit SFP+ ports, status-, link- and PoE LEDs, a Mode/Reset button and an

RJ-45 Console port.

XMS-5248P Front Panel View

Rear Panel

The Rear Panel of the XMS-5248P features a standard AC power input and a redundant power supply (RPS) connector for use with an external power supply.

LED Indicators

The LED indicators on the XMS-5248P include System, Link/Act and PoE LEDs, and an LED for each port. These LED indicators show the operating status of the XMS-5248P and each port connection.

Mode/Reset Button to Change LED Functionality

Tapping the Mode/Reset button briefly switches the port indicator between displaying port link speed and PoE status.

The following chart shows the LED indicators of the XMS-5248P along with an explanation of the indicator’s properties:

Indicator

Name

System

Description

Port Link/

Act Status

1-50

Green Flashing Indicates normal operation.

Green On

Red On

Off

Green

Indicates a malfunction. Contact support.

Indicates power-on system initialization.

Indicates startup/initialization process or that power is not on.

1000Mbps device connected to the port.

Yellow

Flashing

Off

10/100Mbps device connected to the port.

Port receiving or transmitting data.

Nothing connected to the port.

Port PoE

Status 1-50

Green Switch is providing PoE power to a device.

Yellow

Off

PoE is off due to a fault or because the connected device is exceeding power limit.

Port disconnected or link failed.

Note: At startup, the port LEDs will flash briefly during a self-test.

Mode/Reset Button to Reset/Restore

The Reset button (located at the lower-left corner of the front panel) is used to reset (reboot) the switch, or to restore the switch to factory default settings.

X

To Reboot/Reset the Switch: With the XMS-5248P powered on, press the Reset button for approximately three seconds until the Link/Act and

PoE LEDs both light, then release the button.

c CAUTION: Do not hold the button for more than four seconds.

Doing so could erase all settings and restore factory defaults.

X

To Restore Default Settings: With the XMS-5248P powered on, press and hold the Reset button approximately eight seconds, until both the

Link/Act and PoE LEDs turn off, then release the Reset button and the switch automatically restores factory default settings and reboots. Once the System LED starts flashing again, the XMS-5248P is running with factory defaults.

c CAUTION: Please note that restoring Default Settings will remove any/all custom configuration.

Fold Fold Fold

3

Preparing for Access

IP Addressing

If the XMS-5248P is connected to a network with a 192.168.0.X address scheme, and your computer shares a similar address on the same network, you can skip to the next step, Access and Setup.

n Note: If another device on your network shares the 192.168.0.4 address, you’ll need to temporarily reassign or remove that device while you configure the XMS-5248P.

If your network uses an address scheme other than 192.168.0.X, you’ll need to set a temporary static IP address on the computer you’re using for configuration. To do so, set the IP address of your computer to an address in the 192.168.0.X range, then set the Gateway/Router address to 192.168.0.4

(the default IP address of the XMS-5248P).

Once you’re finished configuring the switch, you can return your computer’s IP configuration to normal, typically “Obtain Automatically/DHCP.” n Note: Visit http://luxul.com/ip-addressing to learn more about changing your computer’s IP address and getting connected.

4

Access and Setup

Getting Connected

Use an Ethernet cable to connect your computer to the XMS-5248P, then power on the switch.

Logging In

To access the XMS-5248P web configuration, open your web browser and enter the switch’s default 192.168.0.4 IP address in the address field. Log in to the switch using the default user name and password:

Default IP: 192.168.0.4

Username: admin

Password: admin

Select the menu items on the left to view and/or modify the configuration.

Refer to the Quick Setup Guide at Luxul.com for more detailed information on setup, IP configuration and routing, PoE, VLANs, Spanning Tree, and Stacking.

5

Hardware Operation

Front Panel

The front panel of the XMS-5248P includes 52 Gigabit Ethernet RJ-45 ports, two

Gigabit SFP+ ports, status-, link- and PoE LEDs, a Mode/Reset button and an

RJ-45 Console port.

XMS-5248P Front Panel View

Rear Panel

The Rear Panel of the XMS-5248P features a standard AC power input and a redundant power supply (RPS) connector for use with an external power supply.

LED Indicators

The LED indicators on the XMS-5248P include System, Link/Act and PoE LEDs, and an LED for each port. These LED indicators show the operating status of the XMS-5248P and each port connection.

Mode/Reset Button to Change LED Functionality

Tapping the Mode/Reset button briefly switches the port indicator between displaying port link speed and PoE status.

The following chart shows the LED indicators of the XMS-5248P along with an explanation of the indicator’s properties:

Indicator

Name

System

Description

Port Link/

Act Status

1-50

Green Flashing Indicates normal operation.

Green On

Red On

Off

Green

Indicates a malfunction. Contact support.

Indicates power-on system initialization.

Indicates startup/initialization process or that power is not on.

1000Mbps device connected to the port.

Yellow

Flashing

Off

10/100Mbps device connected to the port.

Port receiving or transmitting data.

Nothing connected to the port.

Port PoE

Status 1-50

Green Switch is providing PoE power to a device.

Yellow

Off

PoE is off due to a fault or because the connected device is exceeding power limit.

Port disconnected or link failed.

Note: At startup, the port LEDs will flash briefly during a self-test.

Mode/Reset Button to Reset/Restore

The Reset button (located at the lower-left corner of the front panel) is used to reset (reboot) the switch, or to restore the switch to factory default settings.

X

To Reboot/Reset the Switch: With the XMS-5248P powered on, press the Reset button for approximately three seconds until the Link/Act and

PoE LEDs both light, then release the button.

c CAUTION: Do not hold the button for more than four seconds.

Doing so could erase all settings and restore factory defaults.

X

To Restore Default Settings: With the XMS-5248P powered on, press and hold the Reset button approximately eight seconds, until both the

Link/Act and PoE LEDs turn off, then release the Reset button and the switch automatically restores factory default settings and reboots. Once the System LED starts flashing again, the XMS-5248P is running with factory defaults.

c CAUTION: Please note that restoring Default Settings will remove any/all custom configuration.

Fold Fold Fold

3

Preparing for Access

IP Addressing

If the XMS-5248P is connected to a network with a 192.168.0.X address scheme, and your computer shares a similar address on the same network, you can skip to the next step, Access and Setup.

n Note: If another device on your network shares the 192.168.0.4 address, you’ll need to temporarily reassign or remove that device while you configure the XMS-5248P.

If your network uses an address scheme other than 192.168.0.X, you’ll need to set a temporary static IP address on the computer you’re using for configuration. To do so, set the IP address of your computer to an address in the 192.168.0.X range, then set the Gateway/Router address to 192.168.0.4

(the default IP address of the XMS-5248P).

Once you’re finished configuring the switch, you can return your computer’s IP configuration to normal, typically “Obtain Automatically/DHCP.” n Note: Visit http://luxul.com/ip-addressing to learn more about changing your computer’s IP address and getting connected.

4

Access and Setup

Getting Connected

Use an Ethernet cable to connect your computer to the XMS-5248P, then power on the switch.

Logging In

To access the XMS-5248P web configuration, open your web browser and enter the switch’s default 192.168.0.4 IP address in the address field. Log in to the switch using the default user name and password:

Default IP: 192.168.0.4

Username: admin

Password: admin

Select the menu items on the left to view and/or modify the configuration.

Refer to the Quick Setup Guide at Luxul.com for more detailed information on setup, IP configuration and routing, PoE, VLANs, Spanning Tree, and Stacking.

5

Hardware Operation

Front Panel

The front panel of the XMS-5248P includes 52 Gigabit Ethernet RJ-45 ports, two

Gigabit SFP+ ports, status-, link- and PoE LEDs, a Mode/Reset button and an

RJ-45 Console port.

XMS-5248P Front Panel View

Rear Panel

The Rear Panel of the XMS-5248P features a standard AC power input and a redundant power supply (RPS) connector for use with an external power supply.

LED Indicators

The LED indicators on the XMS-5248P include System, Link/Act and PoE LEDs, and an LED for each port. These LED indicators show the operating status of the XMS-5248P and each port connection.

Mode/Reset Button to Change LED Functionality

Tapping the Mode/Reset button briefly switches the port indicator between displaying port link speed and PoE status.

The following chart shows the LED indicators of the XMS-5248P along with an explanation of the indicator’s properties:

Indicator

Name

System

Description

Port Link/

Act Status

1-50

Green Flashing Indicates normal operation.

Green On

Red On

Off

Green

Indicates a malfunction. Contact support.

Indicates power-on system initialization.

Indicates startup/initialization process or that power is not on.

1000Mbps device connected to the port.

Yellow

Flashing

Off

10/100Mbps device connected to the port.

Port receiving or transmitting data.

Nothing connected to the port.

Port PoE

Status 1-50

Green Switch is providing PoE power to a device.

Yellow

Off

PoE is off due to a fault or because the connected device is exceeding power limit.

Port disconnected or link failed.

Note: At startup, the port LEDs will flash briefly during a self-test.

Mode/Reset Button to Reset/Restore

The Reset button (located at the lower-left corner of the front panel) is used to reset (reboot) the switch, or to restore the switch to factory default settings.

X

To Reboot/Reset the Switch: With the XMS-5248P powered on, press the Reset button for approximately three seconds until the Link/Act and

PoE LEDs both light, then release the button.

c CAUTION: Do not hold the button for more than four seconds.

Doing so could erase all settings and restore factory defaults.

X

To Restore Default Settings: With the XMS-5248P powered on, press and hold the Reset button approximately eight seconds, until both the

Link/Act and PoE LEDs turn off, then release the Reset button and the switch automatically restores factory default settings and reboots. Once the System LED starts flashing again, the XMS-5248P is running with factory defaults.

c CAUTION: Please note that restoring Default Settings will remove any/all custom configuration.

Sales

P: 801-822-5450

E: [email protected]

Technical Support

P: 801-822-5450 Option 3

E: [email protected]

Copyright and Trademark Notices

No part of this document may be modified or adapted in any way, for any purposes without permission in writing from Luxul. The material in this document is subject to change without notice. Luxul reserves the right to make changes to any product to improve reliability, function, or design. No license is granted, either expressly or by implication or otherwise under any Luxul intellectual property rights. An implied license only exists for equipment, circuits and subsystems contained in this or any Luxul product.

© Copyright 2016 Luxul. All rights reserved. The name Luxul, the Luxul logo, the Luxul logo mark and

Simply Connected are all trademarks and or registered trademarks of Luxul Wireless, Inc. All other trademarks and registered trademarks are property of their respective holders.

LUX-QIG-XMS-5248P-v3 01251710

Fold

QUICK INSTALL GUIDE

52-Port Gigabit PoE+

L2/L3 Managed Switch

XMS-5248P

Includes:

„ XMS-5248P 52-Port PoE Switch

(Includes Rack Mount Kit and Power Cord)

Fold Fold

INSTALLATION AND SETUP

1

Physical Installation

The XMS-5248P can easily be installed in a standard 19” rack. Two mounting ears are included for installing and stabilizing the switch. When attaching the mounting ears and installing the switch in a rack, please refer to the following illustration:

Rack-Mounting the XMS-5248P

„ Using the included screws to attach the mounting ears to each side of the switch.

„ Mount the switch in the rack with the LEDs facing outwards. Be sure the switch is level and properly secured in the rack.

Desktop Setup

For use as a desktop device, position and apply the included rubber feet to the bottom of the XMS-5248P.

2

Connecting Ethernet and Power

Ethernet and Power Connections

Use one of the 50 Ethernet ports to connect the XMS-5248P to any Ethernetenabled device, including servers, routers or other switches.

No crossover cable is necessary.

The XMS-5248P supports 10/100/1000 Mbps Ethernet; 10/100 Mbps half/ full-duplex mode and 1000 Mbps full-duplex mode. Ports 1-48 are PoE+ and are enabled by default. Ports 49 and 50 are Gigabit Ethernet only (non PoE).

Use the included power cable to connect the XMS-5248P to a surge- protected outlet. The AC input socket is on the rear panel. The built-in power supply supports 100~240VAC at 50/60Hz.

The rear panel also features a redundant power supply (RPS) connector. To utlize this feature, you’ll need an external power supply and an appropriate

RPS cable to connect the XMS-5248P to the external power supply.

Network Cabling

Luxul recommends Category-5, super Category-5 or Category-6 unshielded twisted pair (CAT5/CAT5e/CAT6 UTP). To ensure best performance and stable data transmission at 1000 Mbps, use Category-6 shielded twisted pair. c CAUTION: Multiple Uplink channels can create loops, resulting in network failure. Ensure only one Uplink channel exists between switches or between the XMS-5248P and a router.

n NOTE: When powering up, the port LEDs may take a moment to initialize. This is normal as the XMS-5248P initialization and startup sequence completes.

n NOTE: The XMS-5248P has an internal 740W power supply. Do not exceed 25.5W each or 740W combined consumption of all external PoE devices.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement