Trap Seal Primers and Water Hammer Arrestors

Trap Seal Primers and Water Hammer Arrestors
TSP-2013
www.mifab.com
TSP-2013
Go to
www.mifab.com
for the most
current product
specification
sheets.
MI-100
MR-500
CL-A
MI-200
MI-DU-625
MI-701
MI-300
MI-TSP-1
MI-613
Trap Seal Primers and Water Hammer Arrestors
LIT-062
Design and dimensions are subject to modification. Prices do not include applicable taxes. Visit www.mifab.com for the most recent product information.
MIFAB,
West
119thStreet,
Street, Chicago,
60643-5109,
USA USA Toll Free 1-800-465-2736, Fax
Toll Free:
1-800-465-2736,www.mifab.com
Fax: 1-773-341-3049
MIFAB,
Inc. Inc.,
13211321
West
119th
Chicago,Illinois
Illinois
60643-5109,
1-773-341-3049
sales@mifab.com Canada Toll Free: 1-800-387-3880
All sales subject to MIFAB’s Terms and Warranties.
Please refer to inside frontCanada
cover.
sales@mifab.com
Toll Free: 1-800-387-3880
A
TSP-2013
TABLE OF CONTENTS
Continuous Flow Trap Seal Primers (MI-TSP-1, MI-TSP-2, MI-TSP-3).......5
Pressure Balance Valves.............................................................. 12
CSA Certificate of Listing - Trap Seal Primers...........................................21
Pressure Drop Activated Trap Seal Primers
Cross Reference Guide..............................................................................24
(MR-500, M1-500, M2-500)............................................................ 4
Electronic Trap Seal Primers (MI-100, MI-200, MI-300)........................ 6-10
Tailpiece Trap Seal Primers (MI-750)........................................... 11
Gravity Fed Trap Seal Primers (MI-700, MI-701, MI-702)..........................11
Trap Seal Primer Distribution Units (MI-DU-500, MI-DU-625)..... 5
IAPMO Certificate of Listing - Electronic Trap Seal Primers (MI-100)...............18, 19
Trap Seal Primer Selection Guide.......................................... 1, 2, 3
IAPMO Certificate of Listing - Trap Seal Primers and Distribution Units............... 20
Trap Seal Primer Troubleshooting Guide..................................... 13
IAPMO Certificate of Listing - Low Lead Compliance - Trap Seal Primers....... 22,23
Water Hammer Arrestors, Copper, Piston Type........................... 14
P Trap Trap Seal Primer Connector - Cast Iron (MI-600)..........................12
Water Hammer Arrestors, Stainless Steel, Bellows Type............ 15
P Trap Trap Seal Primer Connector - Plastic (MI-602, 610, 620, 630)......12
Water Hammer Arrestors, Heavy Equipment............................... 17
Water Hammer Arrestor Sizing Guide.......................................... 16
TERMS AND CONDITIONS
WHOLESALE DISCOUNT:
Contact MIFAB or your local representative for your applicable discount structure.
FREIGHT ALLOWANCE: Ex Works, MIFAB’s Chicago, Illinois Factory or Manufacturer Representative’s warehouse with full motor freight allowed
on shipments of $1,500.00 Net or more, within the continental U.S.A. or Canada, except Alaska, Hawaii and Puerto Rico. MIFAB reserves the right
to choose the carrier and route of shipment. Alaska: Ex Works, Seattle, WA. Hawaii: Freight allowed on shipments of $1,500.00 or more only when
shipped from West Coast, U.S. Puerto Rico: Ex Works, Miami, Florida. There is no allowance for United Parcel Service, Federal Express or Shipment
by air service. Full motor freight is allowed on shipments of $1,500.00 Net or more, within the continental U.S.A. and Canada for any combination of
BEECO, Counterline, No Hub Coupling, Trench Drain, Access Door and Trap Seal Primer products. Shipping dates are estimates and time of delivery
is not the essence of the sale of the contract. Therefore, under no circumstances will MIFAB have any responsibility on account of any delays in
manufacture, transportation, or otherwise. Additional freight services such as construction site delivery, lift gate delivery service, re-consigned freight
or notification charges, are not included in full freight allowance terms, and will result in additional freight charges.
QUOTATION TERMS: List Price and discount protected for 30 days from date issued by MIFAB. Orders received within this period must be released
for shipment within 30 days from date of purchase order, otherwise, prices will be those that are in effect at the time of shipment.
PAYMENT TERMS: Terms of payment are Net 30 days from the date of the invoice. All pricing in United States currency unless sold in Canada in which
case Canadian dollars is the currency used. The Buyer shall pay all sales, consumers, and / or any other applicable taxes. Past due accounts will be
subject to a 2% per month service charge from the date of the invoice. If any proceedings be instructed by or against Buyer under any bankruptcy
or insolvency law, or if Buyer shall fail to make timely payment on this or any other order, or if, in MIFAB’s judgment, Buyer’s financial situation
justifies such action, MIFAB may, at its election, require payment in advance or cancel the order as to any unshipped item and require payment of
its reasonable cancellation charges. If Buyer delays completion of manufacture, MIFAB may elect to require payment according to percentage of
completion. Equipment held for Buyer shall be at Buyer’s risk and expense. In all cases, regardless of partial payment, title to the Products shall
remain with MIFAB until payment for the Products (including any notes given therefore) has been made in full. Should legal action be necessary to
enforce payment of an unpaid invoice, the Buyer will assume full responsibility for any court costs and reasonable attorney fees. All orders subject to
credit check and approval prior to shipment. Confirmed irrevocable letter of credit or cash in advance of shipment is required for accounts without an
established line of credit. Minimum invoice amount is $100.00. MIFAB reserves the right to apply a minimum order charge to equal $100.00. MIFAB’s
Accounting Department must be notified of potential pricing errors within 30 days of the invoice date. Any terms and conditions stated on Buyer’s
orders which are inconsistent with MIFAB’s quotation and Terms and Warranties shall be of no effect.
RETURNED GOODS RESTOCKING CHARGE: Standard product may be returned within a one year period only with written permission from MIFAB.
All products in catalog are not considered Standard. Standard product to be determined by MIFAB. Returned goods are subject to a 25% restocking
charge, plus cost of reconditioning, if necessary, to make material saleable. Material must be returned to MIFAB freight prepaid only after written
permission from MIFAB to accept the returned material. Buyer must provide copy of the original invoice on which the material was charged. The
original outgoing freight cost to ship the order will be deducted from the credit. Credit allowance will be in the form of merchandise credit only-not cash
credit which must be used within 12 months of the date of issue. The value of a return must total $100.00 to qualify for credit allowance. Galvanized
and acid resistant epoxy coated material will be credited to value of cast iron, and chrome plated at value of nickel bronze. No credit will be allowed
for auxiliary tappings, discontinued, or made to order items. Products designated non stock and / or that have been specially made (require a sign off
drawing by MIFAB) are not subject to return or cancellation.
LIMITED WARRANTY: MIFAB warrants each product against defects in material and workmanship for a period of one year from the date of original
shipment. In the event of such defects within the warranty period, MIFAB will, at its option, replace or recondition the product without charge. This shall
constitute the exclusive remedy for breach of warranty, and MIFAB shall not be responsible for any incidental or consequential damages, including,
without limitation, damages or other costs resulting from labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage
from adverse water conditions, chemicals, or any other circumstances over which MIFAB has no control. This warranty shall be invalidated by any
abuse, misuse, misapplication or improper installation of the product.
MIFAB MAKES NO OTHER WARRANTIES EXPRESSED OR IMPLIED AS PROVIDED IN THIS LIMITED WARRANTY.
ILLUSTRATIONS OR TYPICAL INSTALLATIONS: The typical installations for various products in each product section are intended to illustrate the
products and their options. Under no circumstances are they to be construed as recommended installation procedures. Consult local codes and
project specifications for proper installation instructions.
ALL SALES SUBJECT TO MIFAB’s TERMS AND WARRANTIES.
NOTE: Prices and terms are subject to change without notice and supersede all previous quotations. The right is reserved to change or modify product
design or construction without prior notice and without incurring any obligation to make similar changes and modifications to product previously
or subsequently sold. Contact MIFAB for any clarification.
CONTENTS © MIFAB INC. Copyright 2013
Design and dimensions are subject to modification. Prices do not include applicable taxes. Visit www.mifab.com for the most recent product information.
MIFAB, Inc., 1321 West 119th Street, Chicago, Illinois 60643-5109, USA
All sales subject to MIFAB’s Terms and Warranties. Please refer to inside front cover.
Toll Free: 1-800-465-2736, Fax: 1-773-341-3049
sales@mifab.com Canada Toll Free: 1-800-387-3880
TSP-2013
MIFAB TRAP SEAL PRIMER SELECTION GUIDE
Trap seal primers are a necessity where floor drains are infrequently used and in areas such as mechanical and service rooms. In
surprisingly little time, evaporation of water in floor drain traps will allow sewer gas to enter the interior of the building. Today’s typical
method of cleaning floors produces very little water that runs into floor drains. In mechanical rooms, warm dry conditions and air pressure
changes caused by HVAC equipment may also serve to compromise the water seal. Trap seal primers provide a supply of water to
replenish the deep seal or “P” trap of a drain to prevent sewer or potentially explosive methane gas from entering the area through the
floor drains. They are installed on the potable cold water supply line, and react to water flowing in the line to trigger, either by turbulence or
pressure drop. Once a triggering event occurs, the primer will release water that is piped to a trap primer connector on or near the “P” trap
being maintained. The selection and specification of trap seal primers merits careful consideration. Outlined below are some of the factors
to be aware of when planning to use trap seal primers effectively. Installation and local code requirements must be taken into account when
specifying trap seal primers. The A.S.S.E. (American Society of Sanitary Engineers) trap seal primer standard #1018 is the key standard
that relates to trap seal primers. MIFAB’s M-500 and MI-TSP trap seal primers are tested and certified to the A.S.S.E. 1018 Standard.
MI-TSP-1 ILLUSTRATED
TYPES OF TRAP SEAL PRIMERS
There are four main types of trap seal primers. They include: continuous
flow, pressure drop activated, flush valve operated and electronic.
CONTINUOUS FLOW TRAP SEAL PRIMERS
Continuous flow trap seal primers are the original style of trap seal
primers. They are typically constructed of cast brass or bronze with a
neoprene rubber poppet float on the inside that rises upward as water
flows through the primer. When the poppet rises off of its seat, water
flows from the primer, through the plumbing line connection, and into
the floor drain trap. They are manufactured in either sweat, threaded or
union connections and should be installed in a vertical position within the
horizontal water supply line, at least ten inches above the floor drain trap
that it serves. Continuous flow trap seal primers do not have any method
of screening out line debris. This often results in their clogging and either
flowing water continuously, or not at all. The volume of water that they
discharge is directly related to the amount of water that continuously
flows through them. For these reasons, pressure drop activated trap seal
primers have become the selection of choice for specifiers.
(Continuous flow)
ELECTRONIC TRAP SEAL PRIMERS
MIFAB’s MI-100 Series of electronic trap seal primers
are a pre-assembled electronic trap seal primer system
programmed to maintain the water seal of floor drain traps.
The device is made with an A.S.S.E. approved vacuum
breaker, solenoid valve operated by a timer, shut off
valve for maintenance and a manifold system to distribute
water evenly to the desired floor drain traps. The design
is programmed at MIFAB’s factory with standard flush
times. These flush times can be adjusted by the operator
in order to discharge more or less water to the floor drain
traps, depending on the installation and climate conditions.
Applications include commercial buildings such as schools,
hospitals, manufacturing facilities, and any other buildings
that require floor drain trap seal protection. The distribution
of water from the MI-100 to the traps avoids possible odors
coming from the drains.
Design and dimensions are subject to modification. Prices do not include applicable taxes. Visit www.mifab.com for the most recent product information.
MIFAB, Inc., 1321 West 119th Street, Chicago, Illinois 60643-5109, USA
All sales subject to MIFAB’s Terms and Warranties. Please refer to inside front cover.
Toll Free: 1-800-465-2736, Fax: 1-773-341-3049
sales@mifab.com Canada Toll Free: 1-800-387-3880
1
TSP-2013
MIFAB TRAP SEAL PRIMER SELECTION GUIDE
(Cont’d)
PRESSURE DROP ACTIVATED TRAP SEAL PRIMERS
Pressure drop activated trap seal primers are typically
manufactured out of brass. They are made with a 1/2” M.I.P.
inlet connection and a 1/2” F.I.P. outlet connection. They
have an interior cartridge that seals when the line pressure
is in a static state. When the line pressure drops as little as
three p.s.i. (pounds per square inch) (caused by the flushing
of a toilet, opening of a faucet, or any draw of water from the
water supply line within a close distance to the primer) the
interior cartridge will rise due to the pressure differential within
the primer and a metered amount of water is discharged
under pressure into the plumbing line connected to the
floor drain trap. Pressure drop activated trap seal primers
are supplied with a fine mesh stainless steel filter that will
screen out debris to ensure that the cartridge is not clogged
and that the water deliveries are uniform. The filter is easily
accessible for quick cleaning or replacement. Three different
cartridges offer three different water deliveries into the floor
drain, depending on the number of floor drain traps served
and the evaporation rate of the water in the floor drain traps.
Assuming line pressure of 60 p.s.i, and a line pressure drop
of 3 p.s.i., MIFAB’s MR-500 trap seal primer will discharge
a one half ounce of water, the M1-500 will discharge a full
ounce of water and the M2-500 will discharge a one quarter
ounce of water into the floor drain trap every time the line
pressure changes by 3 p.s.i.
MR-500 ILLUSTRATED
(Pressure drop activated)
FLUSH VALVE TRAP SEAL PRIMERS
Flush valve trap seal primers are installed below the flush
valve and direct an amount of waste water discharged from
the flush valve into a tube that connects to the floor drain
trap to maintain the water seal. Their advantages are that
the water used is already consumed by the flush valve
operation, and this type of primer has no moving parts.
Their disadvantage is that their location is determined by the
location of the fixtures which may be too far away from the
floor drains to be practical; unlike supply line mounted trap
seal primers which can be more easily installed close to the
floor drain trap to be primed. Many installations cannot use
flush valve trap seal primers because the floor drain traps
are too far away to be reached by the flush valve trap seal
primer.
MI-701 ILLUSTRATED
(Flush valve operated)
Design and dimensions are subject to modification. Prices do not include applicable taxes. Visit www.mifab.com for the most recent product information.
2
MIFAB, Inc., 1321 West 119th Street, Chicago, Illinois 60643-5109, USA
All sales subject to MIFAB’s Terms and Warranties. Please refer to inside front cover.
Toll Free: 1-800-465-2736, Fax: 1-773-341-3049
sales@mifab.com Canada Toll Free: 1-800-387-3880
TSP-2013
MIFAB TRAP SEAL PRIMER SELECTION GUIDE
INSTALLATION CONSIDERATIONS
Continuous flow and pressure drop activated trap seal primers
should be installed at least 12” above the floor drain traps for
every 20 feet of distance to the drain to ensure that there is
enough of a slope for the discharged water to flow to the traps.
MIFAB recommends pre-priming the traps, as trap seal primers
are meant to replace trap water loss through evaporation, etc.
Pressure drop activated primers should be connected to the
water supply line with a vertical elbow to limit line debris from
entering and contaminating the valve. The primer itself should
be installed vertically. Access doors should always be specified
to provide easy access to all trap seal primers. Trap seal primers
have moving parts that will eventually wear or be compromised
by line debris even in the best of circumstances. The access
doors specified should be large enough to provide “hand
access” to the trap seal primer, related accessories and line shut
off valve. For quick and easy repair, a line shut off valve and
union connections are recommended directly before the trap
seal primer on the water supply line. The closing of this valve
will facilitate the cleaning and maintenance of the primer without
having to separately shut off the building’s water supply. Water
supply lines should be flushed at least five times before the trap
seal primers are initially installed to ensure that debris will not
enter the primers and negatively affect their performance. Pipe
dope and paste should never be used when installing trap seal
primers in water supply lines because the fine residue from
these adhesives will enter the trap seal primers and clog the
cartridges. Install the trap seal primer as close to the source of
the pressure drop as possible. Fixtures with a water restriction
device may not cause a large enough pressure drop to activate
the trap seal primer.
AIR GAP FITTING
Many local codes require the use of an air gap fitting underneath
the trap seal primer (see MIFAB’s MI-GAP product). The
purpose of an air gap fitting is to provide a vertical space that
is twice the diameter of the water supply connection in order
to ensure positive protection against backflow. ANSI / ASME
Standard A112.1.2 air gap in plumbing systems is written for the
application of air gap fittings. It is recommended that air gaps be
specified for use in areas where splashing water from the air gap
will not be objectionable or cause damage.
DISTRIBUTION UNITS
Distribution units can be installed underneath pressure drop
activated trap seal primers to distribute water to up to ten
floor drain traps that are in close proximity to each other. (See
MIFAB’s MI-DU product) Typically, distribution units are used
when a men and women’s restroom are located side by side with
a common pipe chase between them. In this instance, one trap
seal primer with a distribution unit dialed to the 2 setting can be
used to service both floor drain traps. This eliminates a second
costly installation procedure, shut off valve, access door and air
gap fitting. MIFAB’s distribution units are engineered so that they
(Cont’d)
do not need to be installed level to distribute water evenly and can
be adjusted to serve either two, three or four floor drain traps with a
single unit. Up to ten floor drain traps can be served by having one
main distribution unit feed others below it. Contact MIFAB for layout
information on distribution units serving multiple drains.
LINE SHUT OFF VALVE
The closing of this valve will facilitate the cleaning and maintenance
of the primer without having to separately shut off the building’s
water supply. Water supply lines should be flushed several times
before the trap seal primers are initially installed to ensure that debris
will not enter the primers and negatively affect their performance.
Pipe dope and paste should never be used when installing trap seal
primers in water supply lines because the fine residue from these
adhesives will enter the trap seal primers and clog the cartridges.
Once installed, pressure drop activated trap seal primers should
be cycled at least five times to ensure reliable operation. Quickly
opening and closing the line shut off valve can accomplish this. Four
view holes located directly across from each other at the bottom of
the pressure drop activated trap seal primers allow easy observation
of water discharging into the make up line that leads to the floor
drain trap.
1/2” M.I.P.
1” AIR GAP
5 7/8”
BRASS BODY
1/2” F.I.P. OUTLET
MI-GAP ILLUSTRATED
Design and dimensions are subject to modification. Prices do not include applicable taxes. Visit www.mifab.com for the most recent product information.
MIFAB, Inc., 1321 West 119th Street, Chicago, Illinois 60643-5109, USA
All sales subject to MIFAB’s Terms and Warranties. Please refer to inside front cover.
Toll Free: 1-800-465-2736, Fax: 1-773-341-3049
sales@mifab.com Canada Toll Free: 1-800-387-3880
3
TSP-2013
M-500
PRESSURE DROP ACTIVATED TRAP SEAL PRIMER
REPLACEABLE STAINLESS
STEEL FILTER SCREEN
3 P.S.I PRESSURE DROP
Only a three p.s.i. line pressure drop
is required to activate the primer,
compared to five or ten p.s.i. by
others. Lower water voume fixtures
and faucets has resulted in lower
line pressure drops. A three p.s.i.
performance point ensures reliable
water delivery to maintain the trap
seal.
SEDIMENT FILTER
A replacement stainless steel
sediment filter prevents line debris
from entering the primer. This can
be replaced after wear and build
up of debris to ensure maximum life
and performance of the primer.
NO ADJUSTMENTS
The replaceable and repairable
cartridge tubes inside of the body
are factory engineered to deliver
enough water to service three,
six or ten floor drain traps without
adjustment. This eliminates
confusion during field installation.
A
NO PRECHARGE
MIFAB’s trap seal primers can be
disassembled in the field for easy
cleaning and repair, without risk of
losing a precharge.
VIEW PORTS (4)
VIEW HOLES
Four view holes permit easy
inspection of water delivery. The
holes are across from each other,
enabling light at the opposite end
to illuminate the performance of the
primer.
WRENCH
FLATS
B
All
three
models
are
listed
with I.A.P.M.O. and C.S.A. (File
#110892_0_000) and are tested and
certified to the A.S.S.E. Standard
1018 and are so marked. U.S. Patent #
6,152,164
Note: See pages 20 and 21 for CSA
and IAPMO approval certificates.
M-500 SERIES
LEAD
FREE
LEAD FREE AVAILABLE
(SUFFIX -NPB)
Note: See page 13 for
installation, operation
and maintenance
instructions.
MIFAB MR-500, M1-500 & M2-500
SERIES pressure drop activated brass
trap seal primer, with inlet opening of
1/2” M.I.P. and outlet opening of 1/2”
F.I.P. Complete with four view holes and
removable stainless steel filter screen.
Requires no adjustments and no air
pre-charge.MIFAB’S Series of pressure
activated trap seal primers (MR-500, M1500 and M2-500) can be connected to
any cold water line, and will activate when
a valve or faucet is opened, resulting in at
least a 3 p.s.i. pressure drop. A pressure
drop of three p.s.i. will activate all of
the trap seal primers. MIFAB’s Series
of trap seal primers can be disassembled
in the field. Their unique design permits
filter replacement without affecting the
performance of the primer. The “O”
ring seals are tested for reliability at a
temperature range of -40 degrees to 450
degrees F. The M-500 Series of trap seal
primers do not require adjustment. The
operating range for all of MIFAB’s Series
of trap seal primers is 35-80 p.s.i.
MODEL
LIST PRICE
A
B
PIPE FLATS
DRAINS SERVED
WATER OUTPUT
MR-500
$70.00
4-1/8”
1-1/4”
1-1/8”
6
1/2 oz.
M1-500
$76.50
4-1/8”
1-1/4”
1-1/8”
10
1 oz.
M2-500
$72.00
4-1/8”
1-1/4”
1-1/8”
3
1/4 oz.
M-500 OPTIONAL VARIATIONS
MODEL
NUMBER
DESCRIPTION
SHIP
WEIGHT
CARTON
QTY.
CARTON
WEIGHT
LEAD FREE
MATERIAL
(-NPB)
REPLACEMENT
FILTER SCREEN
(-RF)
REPLACEMENT
CARTRIDGE
(-RC)
MR-500
Up to 6 drains
.75 lbs.
25
18.35 lbs.
No Add
$37.00
$47.25
M1-500
Up to 10 drains
.75 lbs.
25
18.35 lbs.
No Add
$37.00
$53.50
M2-500
Up to 3 drains
.75 lbs.
25
18.35 lbs.
No Add
$37.00
$50.50
$37.00
$53.50
M-500-UN
M-500-UN
For optional Union Connection use suffix (-UN). Read description below.
The union connection (Model # M-500-UN) permits easy access to the top of the trap seal primer for cleaning
and maintenance. Simply solder the pipe to the top of the union nut. Screw the union nut onto the top of the
MR-500, M1-500 or M2-500 trap seal primer during installation. When cleaning or maintenance of the trap
seal primer is required. one can easily unscrew the union nut to access the trap seal primer and not have to
cut the water supply pipe to access the trap seal primer.
Design and dimensions are subject to modification. Prices do not include applicable taxes. Visit www.mifab.com for the most recent product information.
4
MIFAB, Inc., 1321 West 119th Street, Chicago, Illinois 60643-5109, USA
All sales subject to MIFAB’s Terms and Warranties. Please refer to inside front cover.
Toll Free: 1-800-465-2736, Fax: 1-773-341-3049
sales@mifab.com Canada Toll Free: 1-800-387-3880
TSP-2013
MI-TSP
CONTINUOUS FLOW TRAP SEAL PRIMER
MI-TSP-1
1/2” SWEAT CONNECTION
MI-TSP-2
(NPT) THREADED
Note: See pages
20 and 21 for CSA
and IAPMO approval
certificates.
MI-TSP-3
THREADED WITH
UNION CONNECTIONS
T01 UNION
CONNECTION
MODEL NO.
DESCRIPTION
LIST PRICE
ADD FOR:
CHROME PLATED
(-CP)
SHIP
WEIGHT
(Lbs.)
CARTON QTY.
WEIGHT (Lbs.)
MI-TSP-1
1/2” Sweat
SEE MPB
PRICE BOOK
SEE MPB
PRICE BOOK
1.0
20
20
SEE MPB
PRICE BOOK
MI-TSP-2
1/2” Threaded
SEE MPB
PRICE BOOK
SEE MPB
PRICE BOOK
1.0
20
20
SEE MPB
PRICE BOOK
MI-TSP-3
1/2” Threaded with
union connections
SEE MPB
PRICE BOOK
SEE MPB
PRICE BOOK
1.0
20
20
SEE MPB
PRICE BOOK
REPAIR KIT
(-RK)
Part number for MI-TSP-1,2,3, repair kit is MI-TSP-RK. (SUFFIX - RK)
MI-DU
1/8” PHILLIPS HEAD SCREWS (3)
TRAP SEAL PRIMER DISTRIBUTION UNIT
GUIDE MARKER PIN
1/4” DIAMETER
VENTS (4)
GUIDE NUMBERS
(2, 3, 4)
Use 1/2” hard copper
or 1/2” pex with
MI-DU-625
Use 3/8” Type K,
soft copper with
MI-DU-500
1/2” OR 5/8”
COMPRESSION
CONNECTIONS
MIFAB’s MI-DU trap seal primer distribution unit is engineered to
receive a metered amount of water from a trap seal primer and
distribute the water equally to either two, three or four floor drain
traps. Choose from either 1/2” or 5/8” compression connections
by indicating suffix (-500) for 1/2” or suffix (-625) for 5/8”. The lid
of the distribution unit has the numbers “2”, “3” and “4” marked on
it. The body of the distribution unit has a guide marker on the top
of the body. The numbers and the guide marker are positioned
by removing the three screws in the lid of the unit and rotating
the lid to match the appropriate numbers with the guide marker
to provide priming for the desired number of drains. Do not over
torque the three lid screws when securing the lid back to the body.
It is not necessary to install MIFAB’s distribution perfectly level.
The unique design will distribute water uniformly when out of level
up to 5 degrees.
Model MI-DU is listed with I.A.P.M.O.
U.S. Patent #6,142,178.
MODEL
NO.
DESCRIPTION
LIST PRICE -500
(1/2” compression)
LIST PRICE -625
(5/8” compression)
SHIPPING
WEIGHT
CARTON
QTY.
CARTON
WT.
MI-DU
Trap Seal Primer Distribution unit that
serves two, three or four floor drain traps.
$40.00
(for 3/8” copper)
$40.00
(for 1/2” copper)
.75 lbs.
6
4.5 lbs.
Design and dimensions are subject to modification. Prices do not include applicable taxes. Visit www.mifab.com for the most recent product information.
MIFAB, Inc., 1321 West 119th Street, Chicago, Illinois 60643-5109, USA
All sales subject to MIFAB’s Terms and Warranties. Please refer to inside front cover.
Toll Free: 1-800-465-2736, Fax: 1-773-341-3049
sales@mifab.com Canada Toll Free: 1-800-387-3880
5
TSP-2013
MI-100
ENCLOSED ELECTRONIC TRAP SEAL PRIMER
24 VDC, 120 VAC OR 220 VAC CONTROL UNIT WITH 24 HOUR TIMER WITH RELAY.
3/8” FLEXIBLE METAL CONDUIT FITTING
3/4"
BEECO VACCUM BREAKER, LEAD FREE
(ASVB.50-B-LL)
ALL ELBOWS AND
PIPING ARE PLASTIC
TEST BUTTON
MI-100-5
ILLUSTRATED
LEAD
FREE
ELECTRONIC
SOLENOID VALVE
(24, 120 OR 220 VOLT)
16 GAUGE POWDER EPOXY
COATED (WHITE) STEEL
CABINET. FOR CABINET
COVER THAT BOLTS TO
CABINET FRAME,
ADD SUFFIX -AD
12"
1/2"
PLASTIC BALL
VALVE
1 1/2"
MOUNTED HOLES TO
RECEIVE CABINET COVER
3"
3 1/2" DEEP
PLASTIC MANIFOLD
TO SERVE UP TO 35 DRAINS
COMPRESSION PLASTIC
CONNECTORS TO RECEIVE 1/2" PIPING (-500)
OR 5/8” PIPING (-625)
1-10 Outlets = 14 1/2”
1-20 Outlets = 23 1/2”
1-30 Outlets = 33 1/8”
1-35 Outlets = 43 1/2”
The MI-100 is engineered for equal distribution of water to all ports. It’s the perfect solution to keep sewer gas from entering
the building from seldom used floor drains. The MI-100 can be located anywhere in the water supply and is engineered to
permit the building owner to adjust the frequency and amount of water delivery through a timer and solenoid valve. A manifold
ensures that a minimum of 2 ounces of water are delivered to every port over a twenty-four hour period. The unit must be
mounted 12” above the finished floor for every 20’ of water supply line. The MI-100 can be installed with a cabinet cover. The
system is capable of priming from 1 to 35 floor drain traps. The MI-100 is practical to serve many floor drain traps in infrequently
used buildings such as convention centers and sports facilities. The MI-100 is made of lead free materials that touch water.
*NOTE: Cabinet can be surface or flush mounted. The same cabinet
can be installed either way.
Note: See pages 8 and 9 for installation, operation
and maintenance instructions.
1044
Note: See pages 18 and 19 for ASSE and IAPMO
approval certificates.
MI-100
MODEL NO.
DESCRIPTION
LIST PRICE
SHIPPING WT.
MI-100-5
1-5 opening ports with cabinet*
$1,529.00
25 lbs.
MI-100-10
6-10 opening ports with cabinet*
$1,581.00
26 lbs.
MI-100-15
11-15 opening ports with cabinet*
$1,607.00
27 lbs.
MI-100-20
16-20 opening ports with cabinet*
$1,886.00
28 lbs.
MI-100-25
21-25 opening ports with cabinet*
$1,932.00
35 lbs.
MI-100-30
26-30 opening ports with cabinet*
$1,983.00
36 lbs.
MI-100-35
31-35 opening ports with cabinet*
$2,138.00
37 lbs.
See page 7 for a complete list of the MI-100 Optional Variations.
Design and dimensions are subject to modification. Prices do not include applicable taxes. Visit www.mifab.com for the most recent product information.
6
MIFAB, Inc., 1321 West 119th Street, Chicago, Illinois 60643-5109, USA
All sales subject to MIFAB’s Terms and Warranties. Please refer to inside front cover.
Toll Free: 1-800-465-2736, Fax: 1-773-341-3049
sales@mifab.com Canada Toll Free: 1-800-387-3880
TSP-2013
MI-100, MI-200, MI-300 OPTIONAL VARIATIONS
SUFFIX
DESCRIPTION
MI-100 LIST PRICE
MI-200 LIST PRICE
MI-300 LIST PRICE
-A
-AD
Allen key lock for access door (door is separate)
Cabinet Cover (bolted to cabinet frame and non
hinged)
(16 gauge powder epoxy coated steel (white)
$19.00
$140.00
$19.00
$150.00
-ADSS
Stainless Steel (Type 304) Cabinet Cover
(bolted to cabinet frame and non hinged)
(16 gauge fabricated stainless steel (Type 304)
$240.00
$250.00
-BA
-C
Buy American Act compliant product
Cylinder key lock for access door (door is
separate)
Drywall bead frame for access door (5” cabinet
depth) (door is separate)
Steel Cabinet to enclose MI-200 / MI-300 (16
gauge powder epoxy coated steel (white) cabinet
Stainless Steel (Type 304) Cabinet to enclose
MI-200 / MI-300 (16 gauge fabricated stainless
steel (Type 304)
Uninsulated fire rated access door, flush mount
(6” cabinet depth)
Paddle latch for access door (door is separate)
Stainless Steel (Type 304) Cabinet (16 gauge
fabricated stainless steel (Type 304)
(MI-100 only)
$19.00
1-10 Outlets - $150.00
11-20 Outlets - $200.00
21-30 Outlets - $250.00
31-35 Outlets - $300.00
1-10 Outlets - $250.00
11-20 Outlets - $300.00
21-30 Outlets - $350.00
31-35 Outlets - $400.00
P.O.A.
$25.00
P.O.A.
$25.00
P.O.A.
$25.00
P.O.A.
P.O.A.
P.O.A.
N/A
$200.00
$250.00
N/A
$350.00
$400.00
(See AD-2012
List Prices)
$62.50
1-10 Outlets - $500.00
11-20 Outlets - $575.00
21-30 Outlets - $675.00
31-35 Outlets - $775.00
(See AD-2012
List Prices)
(See AD-2012
List Prices)
1-10 Outlets - $250.00
11-20 Outlets - $300.00
21-30 Outlets - $350.00
31-35 Outlets - $400.00
No Add
$75.00
No Add
No Add
No Add
No Add
(See AD-2012
List Prices)
$62.50
N/A
(See AD-2012
List Prices)
$62.50
N/A
(See AD-2012
List Prices)
(See AD-2012
List Prices)
1-5 Outlets - $250.00
(See AD-2012
List Prices)
(See AD-2012
List Prices)
1-5 Outlets - $250.00
No Add
$75.00
No Add
No Add
No Add
No Add
No Add
$75.00
No Add
No Add
No Add
No Add
-DW
-ENC
-ENCSS
-MFRU
-PL
-SS
-UA
Access door, prime coated (5” cabinet depth)
-UASS
Access door, stainless steel (5” cabinet depth)
-2M
Brass Manifold with brass compression
connections
-24VDC
-75WS
-120VAC
-220VAC
-500
-625
24 VDC
3/4” water supply connection
120 VAC
220 VAC
1/2” compression connection ports
5/8” compression connection ports
MI-100-10 illustrated
MI-100-20 illustrated
12”
12”
23 1/2”
14 1/2”
MI-100-30 illustrated
12”
1044
33 1/8”
Design and dimensions are subject to modification. Prices do not include applicable taxes. Visit www.mifab.com for the most recent product information.
MIFAB, Inc., 1321 West 119th Street, Chicago, Illinois 60643-5109, USA
All sales subject to MIFAB’s Terms and Warranties. Please refer to inside front cover.
Toll Free: 1-800-465-2736, Fax: 1-773-341-3049
sales@mifab.com Canada Toll Free: 1-800-387-3880
7
TSP-2013
MI-100 Electronic Trap Seal Primer Installation Instructions
WATER
SUPPLY
ELECTRIC SUPPLY
TIMER
TRAP PRIMER
LINE CONNECTIONS
EXTERIOR
MOUNTING
FLANGES
Description: The MI-100 is a pre-assembled electronic trap seal primer programmed to maintain the water seal of up
to 35 floor drain traps. It is factory programmed to operate at pre-set flush time intervals and can be modified relative
to the site condition or custom requirements. The MI-100 is manufactured with a BEECO vacuum breaker, is easy
to install and is maintenance free. Typical installations are schools, hospitals, laboratories, stadiums, bathrooms,
manufacturing facilities and food processing facilities. The MI-100 meets LEED credit 3.2 and 5.2 for water reduction
and regional material usage.
Approvals: The MI-100 Series is tested and certified to the ASSE 1044 electronic trap seal primer Standard and
listed with I.A.P.M.O. MIFAB can manufacture it with either 24 VDC, 120 VAC or 220 VAC electrical connections.
Installation Guidelines:
1) Properly mount the MI-100 to the wall with # 14 wood or metal screws. It must be level and square. The MI-100
should be secured between wall studs or on the finished wall as close as possible to the drains being serviced.
2) The MI-100 is supplied with exterior mounting flanges for flush to the wall installations. For surface mount
installations, remove the exterior mounting flanges and use the holes in the back of the cabinet to secure it to the
wall.
3) The MI-100 must be installed a minimum of 12” above the highest drain being served. Note that the MI-100
should not be considered a pressure feed trap priming system. The manifold within the MI-100 must always be
installed so that it is higher than the floor drain traps that it serves. The supply lines from the manifold to the floor
drain traps should always be sloped to ensure proper water flow from the manifold to the floor drain traps. The MI100 can be installed up to 100 feet away from the drains they serve as long as the MI-100 is installed high enough
so that there is enough slope from the MI-100 to the drains to ensure water flow.
4) Properly connect the electric and water supply lines by following local codes and guidelines. The water supply
should be connected to the ½” copper tube located on the top of the MI-100. Connect the trap primer supply lines to
the manifold in the MI-100. The black wire is “hot”, the white wire is “neutral” and the green wire is “ground”. Note
that the MI-100-24VDC model is always supplied with a 24 volt converter plug that plugs directly into a 120 volt wall
outlet.
Design and dimensions are subject to modification. Prices do not include applicable taxes. Visit www.mifab.com for the most recent product information.
8
MIFAB, Inc., 1321 West 119th Street, Chicago, Illinois 60643-5109, USA
All sales subject to MIFAB’s Terms and Warranties. Please refer to inside front cover.
Toll Free: 1-800-465-2736, Fax: 1-773-341-3049
sales@mifab.com Canada Toll Free: 1-800-387-3880
TSP-2013
MI-100 Electronic Trap Seal Primer Installation Instructions
5) Connect either 3/8” (3/8” I.D., ½” O.D. tube) or ½” (1/2” I.D., 5/8” O.D. pipe) water supply lines to the manifold
connections (depending on whether the -500 (3/8”) or -625 (1/2”) manifold connections are chosen. Any unused
connection ports of the manifold should be capped off. To do this, remove the entire compression connection from
the underside of the manifold and then thread a ½” M.I.P. plug into the female threaded opening in the manifold.
6) Ensure that the water supply (with a minimum of 20 psig) is connected and then turn on power to the device.
Ensure that the ball valve is open. The MI-100 will then cycle for a half second. Press the Test Button to repeatedly
prime the unit. The Test Button may need to be pressed multiple times in order to have water reach all of the drains.
Observe for any leaks within the MI-100 piping system. Ensure that all lines are free of debris.
Timer Adjustment:
The pre-set timer operates a normally closed solenoid valve. The timer consists of two adjustments. The “ON” time
- this is the amount of time in between flow cycles and is adjustable from 1 to 8 hours. The “OFF” time - this is the
amount of time that the unit is flowing water to the traps – and is adjustable from ½ to 2 seconds. The MI-100-5
and MI-100-10 models are factory set to turn the solenoid valve “ON” every eight hours for a one half second. The
MI-100-15 and MI-100-20 models are factory set to turn the solenoid valve on every eight hours for one second and
the MI-100-25, MI-100-30 and MI-100-35 models are factory set to turn the solenoid valve on every eight hours for
two seconds. MIFAB estimates that when the line pressure is 40 p.s.i., 12 ounces of water will flow from the MI-100
manifold system for every half second that the solenoid valve is on. Note that cold climate installations (meat lockers
and cold storage areas) have an increased rate of evaporation than temperate areas and will therefore need more
water flow to the floor drain traps to maintain the water seal. These settings can be adjusted relative to the amount
of water evaporation in the floor drain traps to ensure that there is a constant water seal in the floor drain traps.
CAUTION: When using the MI-100 electronic trap seal primer, basic precautions should always be followed:
1) Read all of the instructions before installing the MI-100.
2) Do not contact moving parts.
3) Only use the parts recommended or sold by MIFAB.
4) Do not use outdoors.
5) To disconnect, remove the plug from the outlet. Do not unplug by pulling on the cord. To unplug, grasp the plug,
not the cord. Unplug from the outlet when not in use and before servicing or cleaning the MI-100. Do not install or
operate the MI-100 with a damaged cord or plug; or after the MI-100 malfunctions or is dropped or damaged in any
way. If you are experiencing issues, contact your local MIFAB representative.
6) For hard wired connections, disconnect the power when the MI-100 is not in use and before servicing or cleaning.
7) The MI-100 must be connected to a grounded metal, permanent wiring system; or an equipment grounding
conductor must be run with the circuit conductors and be connected to the equipment grounding terminal or lead
on the MI-100.
Design and dimensions are subject to modification. Prices do not include applicable taxes. Visit www.mifab.com for the most recent product information.
MIFAB, Inc., 1321 West 119th Street, Chicago, Illinois 60643-5109, USA
All sales subject to MIFAB’s Terms and Warranties. Please refer to inside front cover.
Toll Free: 1-800-465-2736, Fax: 1-773-341-3049
sales@mifab.com Canada Toll Free: 1-800-387-3880
9
TSP-2013
MI-200
ELECTRONIC TRAP SEAL PRIMERS WITH AIR GAP
1/2" M.I.P. INLET
LEAD
FREE
4 1/2"
6"
SOLENOID
VALVE
3"
1" AIR GAP
BRASS
MI-GAP
1/2"
PLASTIC
PLUG
15 3/8"
5 7/8"
NOTE: Timer not included.
6 3/8"
1044
18" WIRING
HARNESS
INCLUDED
MI-200
1/2"
1 1/2"
3"
PLASTIC MANIFOLD
TO SERVE UP TO
FIVE DRAINS
The MI-200 is engineered to connect to the voltage building energy
management system used to manage the services in commercial,
educational and institutional buildings. It can be located anywhere
in the water supply. A manifold is provided as part of the assembly
so that up to 5 drains can be served. The MI-200 is practical
for infrequently used buildings such as convention centers and
sports facilities. The MI-200 is manufactured in accordance with
ANSI/ASME A112.1.2 air gap in plumbing systems Standard.
UA1818 access door is suggested for access to the MI-200
when installed into the wall.
MODEL NO.
DESCRIPTION
LIST PRICE
SHIPPING WT.
MI-200-24-VDC
24 VDC
$389.00
2 lbs.
MI-200-120-VAC
120 VAC
$389.00
2 lbs.
MI-200-220-VAC
220 VAC
$389.00
2 lbs.
The three models listed in the chart above are without the
manifold. To order the manifold please add suffix -500 for 1/2”
piping or -625 for 5/8” piping.
COMPRESSION PLASTIC CONNECTORS
TO RECEIVE 1/2" PIPING (-500) OR
5/8” PIPING (-625)
10"
See page 7 for a complete list of the MI-200 Optional Variations.
ELECTRONIC TRAP SEAL PRIMER WITH AIR GAP,
DISTRIBUTION UNIT AND CONTROL PANEL
MI-300
LEAD
FREE
7"
1/2" M.I.P. INLET
ELECTRONIC
CONTROLLER
(3 1/2" DEEP)
18"
WIRING
HARNESS
INCLUDED
24 VDC,
120 VAC OR 220
VAC POWER
CONNECTION
5"
3/4"
1/2"
PLASTIC
PLUG
SOLENOID VALVE
1"
AIR
GAP
15 3/8"
The MI-300 is manufactured with a solenoid valve, air gap
manifold and electronic controller. The water discharge frequency
can be adjusted to meet the building’s needs. The MI-300 can be
located anywhere in the water supply. A manifold is connected to
the bottom of the MI-300 to serve up to 5 drains. The MI-300 is
practical for infrequently used buildings such as convention centers
and sports facilities. The MI-300 is manufactured in accordance
with ANSI/ASME A112.1.2 air gap in plumbing systems Standard.
UA 18x18 access door is suggested for
access to the MI-300 when installed in
the wall.
5 7/8"
1044
6 3/8"
BRASS MI-GAP
MI-300
1/2"
1 1/2"
3"
PLASTIC MANIFOLD
TO SERVE UP TO
FIVE DRAINS
COMPRESSION PLASTIC CONNECTORS
TO RECEIVE 1/2" PIPING (-500) OR
5/8” PIPING (-625)
10"
MODEL NO.
DESCRIPTION
LIST PRICE
SHIPPING WT.
MI-300-24-VDC
24 VDC
$842.50
4 lbs.
MI-300-120-VAC
120 VAC
$842.50
4 lbs.
MI-300-220-VAC
220 VAC
$842.50
4 lbs.
The three models listed in the chart above are without the
manifold. To order the manifold please add suffix -500 for 1/2”
piping or -625 for 5/8” piping.
See page 7 for a complete list of the MI-300 Optional Variations.
Design and dimensions are subject to modification. Prices do not include applicable taxes. Visit www.mifab.com for the most recent product information.
10
MIFAB, Inc., 1321 West 119th Street, Chicago, Illinois 60643-5109, USA
All sales subject to MIFAB’s Terms and Warranties. Please refer to inside front cover.
Toll Free: 1-800-465-2736, Fax: 1-773-341-3049
sales@mifab.com Canada Toll Free: 1-800-387-3880
TSP-2013
MI-700
GRAVITY FED TRAP SEAL PRIMERS
MIFAB’s MI-700 Series trap seal primers are
engineered to prime one floor drain trap that
is no further than twenty feet from the fixture.
A 1/2” (13) O.D. copper make-up water line
connecting the trap seal primer to the floor
drain trap is recommended for the M-700 &
MI-701.
1 1/4” M.I.P. THREAD
1 1/2” F.I.P. THREAD
1 1/2” F.I.P. THREAD
2 3/16”
2 1/4”
4”
Note: S.S. braided supply pipe w/escutcheon
is available for the MI-702 (option -BH).
List price is $43.50 for the -BH option.
6”
5 1/2”
8 1/2”
11 1/2”
19”
6”
MI-700
MI-701
MI-702
17 GAUGE CHROME
PLATED CAST BRASS BODY
MODEL NO.
MI-700
MI-701
MI-702-9.5
MI-702-12.5
MI-702-15.5
MI-702-23
DESCRIPTION
1 1/4” Lavatory Trap Seal Primer
1 1/2” Valve Trap Seal Primer
1 1/2” Valve Trap Seal Primer w/ VB, 9 1/2” Long
1 1/2” Valve Trap Seal Primer w/ VB, 12 1/2” Long
1 1/2” Valve Trap Seal Primer w/ VB, 15 1/2” Long
1 1/2” Valve Trap Seal Primer w/ VB, 23 1/2” Long
LIST PRICE
$58.00
$73.50
$75.00
$78.00
$80.00
$82.50
SHIP WEIGHT
(Lbs.)
0.75
1.25
1.25
1.50
1.75
2.25
CARTON QTY.
20
20
20
20
20
20
CARTON WEIGHT
(Lbs.)
15.00
25.00
25.00
30.00
35.00
45.00
List price is $43.50 for the -BH option.
TAILPIECE TRAP SEAL PRIMER WITH BRAIDED CONNECTING HOSE
MI-750
CHROME PLATED
ESCUTCHEONS
INCLUDED
17 GAUGE CHROME
PLATE TAIL PIECE
11.5
1/2” SLIP JOINT
1/2” M.I.P.
CONNECTION
1.5
1.5
3
5.0
4.938
1/2” M.I.P.
CONNECTION
1/4” M.I.P.
CONNECTION
FLEXIBLE
BRAIDED PRIMER HOSE
TRAP CLEANOUT
17 GAUGE CHROME
PLATE CAST BRASS BODY
Note: Both 1 1/2” and 1 1/4” slip joint nuts are provided.
MODEL NUMBER
DESCRIPTION
LIST PRICE
MI-750
Tailpiece Trap Seal Primer
SEE MPB PRICE BOOK
Design and dimensions are subject to modification. Prices do not include applicable taxes. Visit www.mifab.com for the most recent product information.
MIFAB, Inc., 1321 West 119th Street, Chicago, Illinois 60643-5109, USA
All sales subject to MIFAB’s Terms and Warranties. Please refer to inside front cover.
Toll Free: 1-800-465-2736, Fax: 1-773-341-3049
sales@mifab.com Canada Toll Free: 1-800-387-3880
11
TSP-2013
MI-600-50
CAST IRON P-TRAP SEAL PRIMER CONNECTOR
2”, 3”, 4”
TRAP PRIMER
BOSS WITH 1/2” N.P.T.
TAPPING
4”
MODEL
NUMBER
PIPE
SIZE
MI-602,3,4-50
2”, 3”, 4”
8”
4”
DESCRIPTION
LIST PRICE
Cast Iron Trap
Primer Adapter
SEE MPB
PRICE BOOK
MI-600-50 SERIES OPTIONAL VARIATIONS:
MI-600
4”
(102)
3”
(76)
4”
(102)
2”
(51)
DESCRIPTION
LIST PRICE
-13
All galvanized
SEE MPB PRICE BOOK
ABS OR PVC “P-TRAP” TRAP SEAL PRIMER CONNECTOR
8”
(203)
5 3/4”
(416)
SUFFIX
MODEL
NUMBER
CONNECTION
SIZE
DESCRIPTION
COMPRESSION
SHIPPING
MATERIAL
CARTON
WEIGHT
CARTON
QTY.
WEIGHT
LIST
PRICE
MI-602
2”
1/2”
ABS
.30 lbs.
24
7.20 lbs.
$30.00
MI-603
3”
1/2”
ABS
.50 lbs.
18
9.00 lbs
$32.00
MI-604
4”
1/2”
ABS
.70 lbs.
12
8.40 lbs
$35.00
MI-612
2”
5/8”
ABS
.30 lbs.
24
7.20 lbs.
$30.00
MI-613
3”
5/8”
ABS
.50 lbs.
18
9.00 lbs.
$32.00
MI-614
4”
5/8”
ABS
.70 lbs.
24
8.40 lbs.
$35.00
MI-622
2”
1/2”
PVC
.30 lbs.
24
7.20 lbs.
$30.00
MI-623
3”
1/2”
PVC
.50 lbs.
18
9.00 lbs.
$32.00
MI-624
4”
1/2”
PVC
.70 lbs.
12
8.40 lbs.
$35.00
MI-632
2”
5/8”
PVC
.30 lbs.
24
7.20 lbs.
$30.00
MI-633
3”
5/8”
PVC
.50 lbs.
18
9.00 lbs
$32.00
MI-634
4”
5/8”
PVC
.70 lbs.
12
8.40 lbs.
$35.00
MI-TEMP
AUTOMATIC PRESSURE BALANCE VALVE
The MI-TEMP holds a selected water temperature to within one degree from any
constant hot water supply regardless of pressure changes in the supply lines.
It ensures a blend of mixed hot and cold water at the shower head and is fully
automatic - only one moving part will equalize the hot and
cold supply line pressures. As supply line pressures fluctuate,
LEAD
the brass piston will move enough to compensate for the
FREE
change in pressure and release water only at the preselected
temperature.
INSTALLATION: The MI-TEMP can be installed anywhere on a 1/2” (13) water supply line at any angle or position ahead of the control
valve(s). When not equipped with an integral shutoff or where there is a shutoff valve installed after the control valve, there shall be stop
and check valves on the inlet(s). It can be used with one or two handle valve assemblies and does not need to be installed level. Do not
make direct, high temperature soldering connections to the valve body. When making a copper sweat connection, make the adapter
solder joint first, then screw the connector into the valve body. The MI-TEMP should be provided with some type of access for servicing
if necessary. The MI-TEMP can be installed in commercial, institutional, government, educational and residential locations - anywhere
a control of water temperature is required. Do not install the MI-TEMP until ready for final inspection. Standing water will render the
valve inoperable. See MI-TEMP specification sheet on www.mifab.com for maintenance instructions.
MODEL NO.
DESCRIPTION
FLOW RATE
LIST PRICE
SHIPPING WT.
CARTON QTY.
CARTON WT.
MI-TEMP-NPB
Automatic Pressure Balance Valve
12 GPM
$150.00
1.60 lbs.
30
48 lbs.
MI-TEMP-RK
Repair kit for MI-TEMP
12 GPM
$80.00
0.30 lbs.
1
0.30 lbs.
Design and dimensions are subject to modification. Prices do not include applicable taxes. Visit www.mifab.com for the most recent product information.
12
MIFAB, Inc., 1321 West 119th Street, Chicago, Illinois 60643-5109, USA
All sales subject to MIFAB’s Terms and Warranties. Please refer to inside front cover.
Toll Free: 1-800-465-2736, Fax: 1-773-341-3049
sales@mifab.com Canada Toll Free: 1-800-387-3880
TSP-2013
TRAP SEAL PRIMER TROUBLESHOOTING
Following are some things to trouble shoot when it comes to our M-500 Series of
Trap Seal Primers (M1-500, M2-500, MR-500):
1) What is the line pressure for the installation?
The M-500 Series of trap seal primers will work within a line pressure range of 35 – 80 psi. Do not subject the trap seal primer to pressure in excess of 80
psi. The trap seal primer must be installed on a cold fresh water line of 1 ½” diameter or less.
2) How far away is the trap primer from the source of the pressure drop?
Anything farther away than 20 feet is an issue, as the farther the primer is away from the source of the pressure drop, the less likely it will sense it and work.
3) What is the pressure drop where the primer is?
MIFAB’s M-500 Series of primers will work with as little as 3 psi in pressure drop. With today’s low flow and consumption faucets, there is less pressure
drop being created when the faucets and toilets are used. Therefore, it is recommended to install the trap seal primer as close to the low flow fixture as
possible.
4) Water hammer arrestors on the line can also affect pressure drop in the line.
It would be best to get a pressure reading where the trap primer is installed. The M-500 series needs a fast, sharp pressure drop to activate. The long pipe
run to the trap primer and the water hammer arrestor may not be allowing the trap primer to function properly.
5) Look at the gauge fluctuation
Is it a quick and sharp pressure drop? Or did it gradually drop? The trap primers need a quick pressure drop to activate. A slow gradual pressure drop
may not be enough to activate the M-500. That is why we state that they should be as close to the pressure drop source as possible. The M1-500 has the
most buoyant cartridge and should perform the best. If the trap primer looked good and was filled with water then it is the rate of the pressure drop that
is causing the issue.
6) Water heaters
Do not install the trap seal primer on a water heater line due to insufficient pressure drop.
7) Not working
In some cases, the installation conditions cannot deliver the required 3 psi pressure drop to activate MIFAB’s MR-500, M1-500 and / or M2-500 trap seal
primers. In such cases, MIFAB recommends the use of the MI-TSP-1 (page 5) continuous flow trap seal primer which does not require a pressure drop
to activate or the MI-100 (page 6) Series of electronic trap seal primers which also do not require a pressure drop and are electronically programmed to
deliver a specific amount of water at specific time intervals.
Also refer to the copy in the Trap Seal Primer section (Pages 1-4).
M-500 SERIES INSTALLATION INSTRUCTIONS:
Use a 1 1/8” open end wrench to install the M-500 Series of trap seal primers to the line by using the flats on the top of the trap seal primer. Water
lines must be flushed before installing MIFAB’s MR-500 Series of trap seal primers. The leading cause of trap seal primer performance problems is
interference from foreign debris. The trap seal primers should be cycled at least six times to reduce problems of interference from foreign debris. The
following steps are highly recommended:
- Ensure that all flux and other debris is removed from supply line to the primer.
- Use only teflon tape around threads, NEVER use pipe dope.
- Do not solder fittings directly onto the inlet or outlet of the primer, as the primer uses a PE (polyethylene) cartridge.
Failure to follow these instructions will negatively affect performance of the product. MIFAB’s primers have a unique design which allows the primer to
be taken apart and cleaned before re-assembly. Do this in the event of excess water discharge.
WATER SUPPLY “T’s” UP FROM
Trap seal primers should be mounted one foot above the finished floor for every twenty feet of
THE PIPE TO LIMIT DEBRIS
floor drain trap make-up water line. For easy access to the trap seal primer, install a union connection
UNION CONNECTION
above it. Install a line shut off valve upstream of the trap seal primer in order to shut off the water
*DO NOT SOLDER WITH
PRIMER IN PLACE*
supply when performing maintenance on the trap seal primer.
(MIFAB PART #M-500-UN)
INSPECTION INSTRUCTIONS:
After installing and pre-cycling the trap seal primer, use any of the four holes to view water
discharge from the orfice. A light can be placed opposite the viewing hole to improve clarity in
this inspection.
MAINTENANCE INSTRUCTIONS:
In order to replace the filter screen, remove the trap seal primer by using an open end wrench
on the top set of flats. Grasp the top of the filter screen with fingers, squeeze and remove the filter.
Insert the new filter screen by squeezing and pushing it firmly down into the top of the trap seal primer.
Re-install the trap seal primer using the top set of flats. In regions that experience heavy residual
deposits such as calcium in the water supply, MIFAB’s M-500 Series of trap seal primers can be
field refurbished by removing the bottom end of the primer, and replacing the cartridge.
Go to www.mifab.com for more information on maintenance of trap seal primers.
REMOVE BOTTOM
TO REPLACE
CARTRIDGE
MI-DU-625
DISTRIBUTION
UNIT
Design and dimensions are subject to modification. Prices do not include applicable taxes. Visit www.mifab.com for the most recent product information.
MIFAB, Inc., 1321 West 119th Street, Chicago, Illinois 60643-5109, USA
All sales subject to MIFAB’s Terms and Warranties. Please refer to inside front cover.
Toll Free: 1-800-465-2736, Fax: 1-773-341-3049
sales@mifab.com Canada Toll Free: 1-800-387-3880
13
TSP-2013
CL / CLS
PISTON TYPE WATER HAMMER ARRESTORS
• Thick walled one piece, hard drawn “K”copper seamless body. Unique design eliminates
separate end cap connection to ensure maximum integrity of the body and guarantees
free movement of the piston for maximum performance.
• Ryton PPS piston with two Parco #5778-80 O-rings and Dow Corning #111 FDA
approved silicone lubricant. Ribbed piston design reduces secondary shock and flared
piston skirt prevents hard particles suspended in the water supply from contacting the
O-rings to provide increased product life.
• Large volume air chamber provides better dampening for superior water hammer
arrestor performance.
• Temperature range: Maximum working temperature is 250º F.
• Operating pressure: Up to 350 PSIG
A
• Surge pressure: Up to 1,500 PSIG
• No access door is required to service MIFAB’s water hammer arrestors.
Tested and certified to the A.S.S.E. 1010 and A.N.S.I. A112.26.4M Standards
and listed with I.A.P.M.O. Patent # 6,539,976
CLS-AA-1/2
illustrated
B
CL-AA illustrated
CLS SERIES
MODEL NUMBER
SINGLE PIECE WT.
DESCRIPTION
UNIT FIXTURE
UNITS PER BOX
LIST PRICE
PER UNIT
CLS-AA-1/2
.30 lbs.
1/2” male sweat connection
1-3
50
$13.45
CLS-AA-3/4
.35 lbs.
3/4” male sweat connection
1-3
50
$17.00
MODEL
NUMBER
FIXTURE
UNITS
(A)
LENGTH
SWT.
CONN. SIZE
SINGLE PIECE
WEIGHT
MASTER
CARTON QTY.
MASTER
CARTON WT.
LIST PRICE
PER UNIT
CLS-A
1-11
8-1/4”
1/2”
.52 lbs.
44
23 lbs.
$18.20
CLS-B
12-30
10”
3/4”
.75 lbs.
32
24 lbs.
$21.75
CLS-C
31-60
12-1/2”
1”
1.39 lbs.
22
30.5 lbs.
$53.00
CLS-D
61-113
11”
1”
2.06 lbs.
8
16.5 lbs.
$68.00
CLS-E
114-154
13-1/2”
1”
2.5 lbs.
7
17.5 lbs.
$91.00
CLS-F
155-330
16”
1”
2.92 lbs.
6
17.5 lbs.
$139.00
CL SERIES
MODEL
NUMBER
ASSE
RATING
FIXTURE
UNITS
(A)
LENGTH
(B) THREADED
CONNECTION SIZE
SINGLE PIECE
WEIGHT
CL-AA
CL-A
MASTER
CARTON QTY.
MASTER
CARTON WT.
AA
1-3
4-3/4”
1/2”
A
1-11
6”
1/2”
LIST PRICE
PER UNIT
.33 lbs.
50
16.5 lbs.
$14.50
.45 lbs.
60
27 lbs.
$20.00
CL-B
B
12-30
7-1/2”
3/4”
.55 lbs.
42
23 lbs.
$24.00
CL-C
C
31-60
9”
1”
1 lb.
24
24 lbs.
$57.25
CL-D
D
61-113
10-1/2”
1-1/4”
2.38 lbs.
8
19 lbs.
$74.50
CL-E
E
114-154
11-1/4”
1-1/2”
3 lbs.
6
18 lbs.
$99.50
CL-F
F
155-330
13”
2”
5.83 lbs.
6
35 lbs.
$150.00
Design and dimensions are subject to modification. Prices do not include applicable taxes. Visit www.mifab.com for the most recent product information.
14
MIFAB, Inc., 1321 West 119th Street, Chicago, Illinois 60643-5109, USA
All sales subject to MIFAB’s Terms and Warranties. Please refer to inside front cover.
Toll Free: 1-800-465-2736, Fax: 1-773-341-3049
sales@mifab.com Canada Toll Free: 1-800-387-3880
TSP-2013
WHB
STAINLESS STEEL BELLOWS WATER HAMMER ARRESTORS
“C”
NITROGEN
AND HELIUM
GAS
PRE-CHARGE
TYPE 304
STAINLESS
STEEL BODY
“A”
STAINLESS
STEEL BELLOWS
INSIDE
TYPE 304
STAINLESS
STEEL NPT.
CONNECTION
“B”
MODEL
NUMBER
PDI RATING
FIXTURE
UNITS
PIPE SIZE
“A” HEIGHT
“B” CONN.
SIZE
“C” DIAMETER
LIST PRICE
WHB-A
A
1-11
3/4”
3 3/8”
3/4”
3 3/8”
See MPB Price
Book
WHB-B
B
12-30
1”
4”
1”
3 3/8”
See MPB Price
Book
WHB-C
C
31-60
1”
4 3/8”
1”
3 3/8”
See MPB Price
Book
WHB-D
D
61-113
1”
5 3/8”
1”
3 3/8”
See MPB Price
Book
WHB-E
E
114-154
1”
7 1/4”
1”
3 3/8”
See MPB Price
Book
WHB-F
F
155-330
1”
7 1/4”
1”
3 3/8”
See MPB Price
Book
Note: Specify suffix –BA for Buy America Act and/or American Recovery and Reinvestment Act compliant product.
Design and dimensions are subject to modification. Prices do not include applicable taxes. Visit www.mifab.com for the most recent product information.
MIFAB, Inc., 1321 West 119th Street, Chicago, Illinois 60643-5109, USA
All sales subject to MIFAB’s Terms and Warranties. Please refer to inside front cover.
Toll Free: 1-800-465-2736, Fax: 1-773-341-3049
sales@mifab.com Canada Toll Free: 1-800-387-3880
15
TSP-2013
WATER HAMMER ARRESTOR SIZING
Single and Multiple Fixture Branch Lines
The water hammer arrestor sizing procedure for single
and multiple fixtures described below conforms to
that established by the American Society of Sanitary
Engineers in their Standard ASSE-1010. Selection
of the water hammer arrestor is based upon the total
quantity of Fixture-Units on each cold and hot water
branch line.
Fixture-Unit Listing
Determine the total number of Fixture-Units on each
branch line by referring to the list of fixtures in Table
One.
Water Hammer Arrestor Selection
Refer to Table Two and select the waterhammer
arrestor model with proper Fixture-Unit capacity. In long
batteries of fixtures over 20 feet in length, more than
one water hammer arrestor will be required.
(See placement data shown below.)
WATER HAMMER ARRESTOR
PLACEMENT DATA
On multiple fixture branch lines up to 20 feet in length,
the water hammer arrestor should be installed on the
branch line between the last two fixtures being served.
The water hammer arrestor should have a Fixture-Unit
rating equal to or greater than the total Fixture-Units
connected to the branch line.
Table One
Weight in Fixture Units
Public
Fixture
Water Closet
Water Closet
Pedestrial Urinal
Stall or Wall Urinal
Stall or Wall Urinal
Lavatory
Bathtub
Shower Head
Bathroom Group
Bathroom Group
Separate Shower
Service Sink
Laundry Tubs (1-3)
Combination Fixture
Type of Supply Control
Flush Valve
Flush Tank
Flush Valve
Flush Valve
Flush Tank
Faucet
Faucet
Mixing Valve
Flush Valve Closet
Flush Tank Closet
Mixing Valve
Faucet
Faucet
Faucet
C.W.
10
5
10
5
3
1 1/2
2
2
3
-
H.W.
1 1/2
2
2
3
-
Private
C.W.
6
3
1
1 1/2
1
8
6
1
3
3
H.W.
1
1 1/2
2
3
3
2
3
3
Table Two
Water Hammer Arrestor
Model No.
Fixture Unit Capacity
A
B
C
D
1-11
12-32
33-60
61-113
E
F
114-154 155-330
NOTES:
(1) All sizing data in this book are based on flow velocities of 10 feet per second or less.
(2) When the static water pressure in the line exceeds 65 psig, contact the MIFAB Engineer Department.
(3) If the fixture-unit total has 1/2” fraction, it is to be “rounded-up” to the next larger whole
On multiple fixture branch lines over 20 feet in length, number. If the total is 11 1/2 fixture units, use 12 fixture units.
two water hammer arrestors should be used on each
line with the second unit placed at the approximate
midpoint of the line. The sum of the Fixture-Unit ratings
of the water hammer arrestors on each branch should
be equal to or greater than the total Fixture-Units
connected to the branch line.
Design and dimensions are subject to modification. Prices do not include applicable taxes. Visit www.mifab.com for the most recent product information.
16
MIFAB, Inc., 1321 West 119th Street, Chicago, Illinois 60643-5109, USA
All sales subject to MIFAB’s Terms and Warranties. Please refer to inside front cover.
Toll Free: 1-800-465-2736, Fax: 1-773-341-3049
sales@mifab.com Canada Toll Free: 1-800-387-3880
TSP-2013
WHS
WATER HAMMER ARRESTORS FOR HEAVY EQUIPMENT
VALVE ASSEMBLY
MODEL
NUMBER
PRESSURE GAUGE
WEIGHT
(LBS.)
GAS CAPACITY
(Cubic Inches)
FLUID
DISPLACEMENT
(Cubic inches)
HOUSING
DIA. (Inches)
HOUSING
HEIGHT
(Inches)
CONNECTION
SIZE
LIST
PRICE
WHS-1
80
200
120
WHS-2
140
500
300
10 1/2”
10”
2” M.I.P.
SEE MPB PRICE BOOK
16”
10 3/4”
2” M.I.P.
SEE MPB PRICE BOOK
WHS-3
150
1,000
600
16”
14”
2” M.I.P.
SEE MPB PRICE BOOK
WHS-4
300
2,000
1,200
24”
18”
3” Flange
SEE MPB PRICE BOOK
Design and dimensions are subject to modification. Prices do not include applicable taxes. Visit www.mifab.com for the most recent product information.
MIFAB, Inc., 1321 West 119th Street, Chicago, Illinois 60643-5109, USA
All sales subject to MIFAB’s Terms and Warranties. Please refer to inside front cover.
Toll Free: 1-800-465-2736, Fax: 1-773-341-3049
sales@mifab.com Canada Toll Free: 1-800-387-3880
17
TSP-2013
IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a
combination of both to verify compliance to the requirements of applicable codes and standards. This activity is coupled with periodic surveillance of the
supplier's factory and warehouses as well as the assessment of the supplier's Quality Assurance System. This listing is subject to the conditions set forth in
the characteristics below and is not to be construed as any recommendation, assurance or guarantee by IAPMO Research and Testing, Inc. of the product
acceptance by Authorities Having Jurisdiction.
Effective Date:
October 2012
Void After: October 2013
Product:
Trap Seal Primer Devices – Drainage Types
and Electronic Design Types
Issued To:
Mifab
1321 West 119th Street
Chicago, IL 60643-5109
Identification:
Cast brass elbows shall contain the manufacturer's name or trademark, and
File No. 7746
model number. The product shall also bear the UPC® certification mark.
Characteristics:
Cast brass p-trap/trap primer utilizing grey water from a plumbing fixture.
To be installed in accordance with the manufacturer's instructions and the
latest edition of the Uniform Plumbing Code.
Products listed on this certificate have been tested by an IAPMO R&T
recognized laboratory.
This recognition has been granted based upon the
laboratory's compliance to the applicable requirements of ISO/IEC 17025.
Products are in compliance with the following code(s):
Uniform Plumbing Code (UPC®)
Products are in compliance with the following standard(s):
ASSE 1044-2001
For the most accurate and updated information please visit http://pld.iapmo.org/7746
This listing period is based upon the last date of the month indicated on the Effective Date and Void After Date shown above. Any change in material,
manufacturing process, marking or design without having first obtained the approval of the Product Certification Committee, or any evidence of
non-compliance with applicable codes and standards or of inferior workmanship, may be deemed sufficient cause for revocation of this listing.
Production of or reference to this form for advertising purposes may be made only by specific written permission of IAPMO Research and Testing, Inc.
Any alteration of this certificate could be grounds for revocation of the listing.
Design and dimensions are subject to modification. Prices do not include applicable taxes. Visit www.mifab.com for the most recent product information.
18
MIFAB, Inc., 1321 West 119th Street, Chicago, Illinois 60643-5109, USA
All sales subject to MIFAB’s Terms and Warranties. Please refer to inside front cover.
Toll Free: 1-800-465-2736, Fax: 1-773-341-3049
sales@mifab.com Canada Toll Free: 1-800-387-3880
TSP-2013
Page 2
Void After: October 2013
Product:
Issued To:
Trap Seal Primer Devices – Drainage Types and
Electronic Design Types
Mifab
File No. 7746
MODELS:
MI-100-5
MI-100-10
MI-100-15
MI-100-20
MI-100-25
MI-100-30
MI-100-35
Design and dimensions are subject to modification. Prices do not include applicable taxes. Visit www.mifab.com for the most recent product information.
MIFAB, Inc., 1321 West 119th Street, Chicago, Illinois 60643-5109, USA
All sales subject to MIFAB’s Terms and Warranties. Please refer to inside front cover.
Toll Free: 1-800-465-2736, Fax: 1-773-341-3049
sales@mifab.com Canada Toll Free: 1-800-387-3880
19
TSP-2013
IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a
combination of both to verify compliance to the requirements of applicable codes and standards. This activity is coupled with periodic surveillance of the
supplier's factory and warehouses as well as the assessment of the supplier's Quality Assurance System. This listing is subject to the conditions set forth in
the characteristics below and is not to be construed as any recommendation, assurance or guarantee by IAPMO Research and Testing, Inc. of the product
acceptance by Authorities Having Jurisdiction.
Effective Date:
November 2012
Void After: November 2013
Product:
Trap Seal Primers Valves
Issued To:
Mifab, Inc.
1321 West 119th Street
Chicago, IL 60643
Identification:
Marking shall be permanently affixed to, stamped or cast on the body of the
File No. 3823
valve with manufacturer's name or marketers name or trademark, operating
range, model number or other identification.
The product shall also bear the
UPC® certification mark.
Characteristics:
Trap seal primer valves designed for water working pressure of at least 125
psi (961 KPa) and to supply water to the trap to provide and maintain its
water seal.
Supply line and trap makeup water supply connections shall be
minimum 1/2" (12.7 mm) pipe size.
To be installed in accordance with the
manufactures instructions and the requirements of the Uniform Plumbing Code.
Products listed on this certificate have been tested by an IAPMO R&T
recognized laboratory.
This recognition has been granted based upon the
laboratory's compliance to the applicable requirements of ISO/IEC 17025.
Products are in compliance with the following code(s):
Uniform Plumbing Code (UPC®)
International Plumbing Code (IPC®)
For the most accurate and updated information please visit http://pld.iapmo.org/3823
This listing period is based upon the last date of the month indicated on the Effective Date and Void After Date shown above. Any change in material,
manufacturing process, marking or design without having first obtained the approval of the Product Certification Committee, or any evidence of
non-compliance with applicable codes and standards or of inferior workmanship, may be deemed sufficient cause for revocation of this listing.
Production of or reference to this form for advertising purposes may be made only by specific written permission of IAPMO Research and Testing, Inc.
Any alteration of this certificate could be grounds for revocation of the listing.
MODELS:
MI-DU,
MI-TSP-3,
M2-500
MI-TSP-1,
MR-500,
MI-TSP-2,
MI-500,
Design and dimensions are subject to modification. Prices do not include applicable taxes. Visit www.mifab.com for the most recent product information.
20
MIFAB, Inc., 1321 West 119th Street, Chicago, Illinois 60643-5109, USA
All sales subject to MIFAB’s Terms and Warranties. Please refer to inside front cover.
Toll Free: 1-800-465-2736, Fax: 1-773-341-3049
sales@mifab.com Canada Toll Free: 1-800-387-3880
TSP-2013
Page 1 of 1
Certification Record
CUSTOMER
CLASS
FILE
MIFAB, Inc.
6803-10
PLUMBING FITTINGS-Trap
Primers
110892_0_000
1321 West 119th St,
Chicago
IL
60643
USA
Refer to Class Description for program details
Trap Seal Primer Valves: MI-TSP-1, MI-TSP-2, MI-TSP-3, MR-500, MI-500, M2-500.
/sp
Copyright © 2012 CSA International. All rights reserved.
http://directories.csa-international.org/xml_transform.asp?xml=certxml\110892_0_000-6...
10/28/2012
Design and dimensions are subject to modification. Prices do not include applicable taxes. Visit www.mifab.com for the most recent product information.
MIFAB, Inc., 1321 West 119th Street, Chicago, Illinois 60643-5109, USA
All sales subject to MIFAB’s Terms and Warranties. Please refer to inside front cover.
Toll Free: 1-800-465-2736, Fax: 1-773-341-3049
sales@mifab.com Canada Toll Free: 1-800-387-3880
21
TSP-2013
IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a
combination of both to verify compliance to the requirements of applicable codes and standards. This activity is coupled with periodic surveillance of the
supplier's factory and warehouses as well as the assessment of the supplier's Quality Assurance System. This listing is subject to the conditions set forth in
the characteristics below and is not to be construed as any recommendation, assurance or guarantee by IAPMO Research and Testing, Inc. of the product
acceptance by Authorities Having Jurisdiction.
Effective Date:
May 2012
-Rev. 7/9/2012-
Void After: May 2013
Product:
California Lead Plumbing Law – Devices and Components
Issued To:
Mifab, Inc.
1321 West 119th Street
Chicago, IL 60643-5109
Identification:
Each product shall bear permanent and legible markings to identify the
File No. 6798
manufacturer. This marking shall be the trade name, trademark, or other mark
known to identify the manufacturer. The product and/or product packaging may
also bear the term "Lead Plumbing Law", "Complies with Lead Plumbing Law", or
"Low-Lead" above or in close proximity to the appropriate IAPMO R&T
certification mark, or the term "Certified by IAPMO R&T".
The product
packaging may also bear a grey dot, a check mark with circle, or any other
home centers marking requirements.
Characteristics:
Products listed below are to be installed in accordance with the
manufacturer's instruction. These products have been verified with weighted
average lead content <=0.25%; Solder and flux lead content <=0.2%.
Manufactured in compliance with Section 116875 of the California Health &
Safety Code.
Products listed on this certificate have been tested by an IAPMO R&T
recognized laboratory.
This recognition has been granted based upon the
laboratory's compliance to the applicable requirements of ISO/IEC 17025.
For the most accurate and updated information please visit http://pld.iapmo.org/6798
This listing period is based upon the last date of the month indicated on the Effective Date and Void After Date shown above. Any change in material,
manufacturing process, marking or design without having first obtained the approval of the Product Certification Committee, or any evidence of
non-compliance with applicable codes and standards or of inferior workmanship, may be deemed sufficient cause for revocation of this listing.
Production of or reference to this form for advertising purposes may be made only by specific written permission of IAPMO Research and Testing, Inc.
Any alteration of this certificate could be grounds for revocation of the listing.
Design and dimensions are subject to modification. Prices do not include applicable taxes. Visit www.mifab.com for the most recent product information.
22
MIFAB, Inc., 1321 West 119th Street, Chicago, Illinois 60643-5109, USA
All sales subject to MIFAB’s Terms and Warranties. Please refer to inside front cover.
Toll Free: 1-800-465-2736, Fax: 1-773-341-3049
sales@mifab.com Canada Toll Free: 1-800-387-3880
TSP-2013
Page 2
Product:
Issued To:
-Rev. 7/9/2012 California Lead Plumbing Law – Devices and Components
Mifab, Inc.
Void After: May 2013
File No. 6798
Products are in compliance with the following standard(s):
Section 116875 of the California Health & Safety Code
Models:
MR-500-NPB, M1-500-MPB, M2-500NPB, MI-100-5, MI-100-10, MI-100-15, MI-100-20, MI-100-25, MI100-30, MI-100-35
Design and dimensions are subject to modification. Prices do not include applicable taxes. Visit www.mifab.com for the most recent product information.
MIFAB, Inc., 1321 West 119th Street, Chicago, Illinois 60643-5109, USA
All sales subject to MIFAB’s Terms and Warranties. Please refer to inside front cover.
Toll Free: 1-800-465-2736, Fax: 1-773-341-3049
sales@mifab.com Canada Toll Free: 1-800-387-3880
23
TSP-2013
CROSS REFERENCE
PPP TO MIFAB
TRAP SEAL PRIMERS
PPPMIFAB
AP-500......... (pg.10).......MI-200
Auto Prime... (pg.6)........ MI-100
CPO-500...... (pg.4)...... MR-500
FVP-1VB...... (pg.11)....... MI-702
LPT-1500...... (pg.11)....... MI-750
MP-500-12v... (pg.10)........ MI-300-24VDC
MP-500-115v.....(pg.10).....MI-300-120VAC
Mini Prime.... (pg.10).......MI-300
Oregon # 1... (pg.4)...... MR-500
P-1................ (pg.4)....... M1-500
P1-500.......... (pg.4)....... M1-500
P-2................ (pg.4).......M2-500
P2-500......... (pg.4).......M2-500
PO-500.........(pg.4)....... MR-500
PR-500.........(pg.4)....... MR-500
PR-500NP....(pg.4)..... MR-500-NPB
PR-500SS....(pg.4)........MR-500-SS
Prime - Rite.. (pg.4)...... MR-500
PRO1-500.....(pg.5).... MI-TSP-1
PT Series...... (pg.8)....... MI-100
PTS............... (pg.8)....... MI-100
Solo Prime..... (pg.10).....MI-200
SP-500-24v......(pg.10)...... MI-200-24VDC
SP-500-115v... (pg.10)........MI-200-120VAC
DISTRIBUTION UNITS
PPPMIFAB
DU-2-500.. (pg.5)....MI-DU-500
DU-2-625.. (pg.5).... MI-DU-625
DU-3-500.. (pg.5)....MI-DU-500
DU-3-625.. (pg.5).... MI-DU-625
DU-4-500.. (pg.5)....MI-DU-500
DU-4-625.. (pg.5).... MI-DU-625
DU-U-500. (pg.5)....MI-DU-500
DU-U-625.. (pg.5).... MI-DU-625
PRESSURE BALANCE VALVES
PPPMIFAB
TCP-2.......(pg.12)....... MI-TEMP
TRB-2.......(pg.12)....... MI-TEMP
AIR GAP FITTINGS
PPPMIFAB
AG-500........... (See MPB-2012)
..................................... MI-GAP
RVAG-750CTH...................(See
MPB-2012)................... MI-GAP
P-TRAP ADAPTORS
PPPMIFAB
PPA-2A... (pg.12).... MI-602 / MI-612
PPA-3A... (pg.12).... MI-603 / MI-613
PPA-4A... (pg.12).... MI-604 / MI-614
PPA-2P.... (pg.12).... MI-622 / MI-632
PPA-3P... (pg.12).... MI-623 / MI-633
PPA-4P... (pg.12).... MI-624 / MI-634
WATER HAMMER ARRESTORS
PPPMIFAB
MM-500 SWA..(pg.14)..CLS-AA-1/2
MM-500 TH......(pg.14).....CL-AA-1/2
SC-500......... (pg.14).......... CL-A
SC-500A...... (pg.14).......... CL-A
SC-750......... (pg.14).......... CL-B
SC-750B....... (pg.14).......... CL-B
SC-1000....... (pg.14).......... CL-C
SC-1000C.... (pg.14).......... CL-C
PPP TO MIFAB
JAY R. SMITH TO MIFAB
PPPMIFAB
SC-1250....... (pg.14).......... CL-D
SC-1250D..... (pg.14).......... CL-D
SC-1500....... (pg.14).......... CL-E
SC-1500E..... (pg.14).......... CL-E
SC-2000....... (pg.14).......... CL-F
SC-2000F..... (pg.14).......... CL-F
SWA-500...... (pg.14)....... CLS-A
SWA-750...... (pg.14)....... CLS-B
SWA-1000.... (pg.14)....... CLS-C
SWA-1250.... (pg.14)....... CLS-D
SWA-1500.... (pg.14)....... CLS-E
SWA-2000.... (pg.14)........CLS-F
JRSMIFAB
520-T-B........ (pg.14).......... CL-B
520-T-C........ (pg.14).......... CL-C
520-T-D........ (pg.14).......... CL-D
520-T-E........ (pg.14).......... CL-E
520-T-F......... (pg.14).......... CL-F
5005............. (pg.15)...... WHB-A
5010.............. (pg.15)...... WHB-B
5020............. (pg.15)......WHB-C
5030............. (pg.15)......WHB-D
5040............. (pg.15)...... WHB-E
5050............. (pg.15)...... WHB-F
5205............. (pg.14).......... CL-A
5210.............. (pg.14).......... CL-B
5220............. (pg.14).......... CL-C
5230............. (pg.14).......... CL-D
SIOUX CHIEF TO MIFAB
TRAP SEAL PRIMERS
Sioux Chief
MIFAB
695-01..........(pg.4)....... MR-500
695-Y52........(pg.5)..........MI-DU
695-D20.......(pg.5)..........MI-DU
695-D30.......(pg.5)..........MI-DU
695-D40.......(pg.5)..........MI-DU
695-D432.....(pg.5)..........MI-DU
695-D432F...(pg.5)..........MI-DU
695-D4325...(pg.5)..........MI-DU
WATER HAMMER ARRESTORS
Sioux Chief
MIFAB
660-2........... (pg.14)........... CL-A
652-A........... (pg.14)........... CL-A
653-B.......... (pg.14)........... CL-B
654-C.......... (pg.14)........... CL-C
655-D.......... (pg.14)........... CL-D
656-E.......... (pg.14)........... CL-E
657-F........... (pg.14)........... CL-F
660-S.......... (pg.14)........ CLS-A
652-AS........ (pg.14)........ CLS-A
653-BS........ (pg.14)........ CLS-B
654-CS........ (pg.14)........ CLS-C
655-DS........ (pg.14)........ CLS-D
656-ES........ (pg.14)........ CLS-E
657-FS......... (pg.14).........CLS-F
660-S......(pg.14)....CLS-AA-1/2
660-3S....(pg.14)... CLS-AA-3/4
660-2....... (pg.14).............CL-AA
JAY R. SMITH TO MIFAB
TRAP SEAL PRIMERS
JRSMIFAB
260-SC.....(pg.5)...... MI-TSP-1 / MI-DU
260-T........(pg.5)...... MI-TSP-2 / MI-DU
261-SC. (pg.5)............ MI-TSP-1
261-T.... (pg.5)............MI-TSP-2
2698......... (pg.11)........... MI-750
2699......... (pg. 5).......MI-TSP-2
2699-1...... (pg.5)........ MI-TSP-1
WATER HAMMER ARRESTORS
JRSMIFAB
520-SC-AA... (pg.14).....CLS-AA-1/2
520-SC-A..... (pg.14)....... CLS-A
520-SC-B..... (pg.14)....... CLS-B
520-SC-C..... (pg.14)....... CLS-C
520-SC-D..... (pg.14)....... CLS-D
520-SC-E..... (pg.14)....... CLS-E
520-SC-F..... (pg.14)........CLS-F
520-T-AA...(pg.14)..... CL-AA-1/2
520-T-A........ (pg.14).......... CL-A
JOSAM TO MIFAB
TRAP SEAL PRIMERS
JOSAMMIFAB
88250.......... (pg.5).....MI-TSP-2
88250-90..... (pg.5)..... MI-TSP-1
88250-91..... (pg.5).....MI-TSP-3
88300.......... (pg.4)....... MR-500
WATER HAMMER ARRESTORS
JOSAMMIFAB
75001-A.....(pg.15)......... WHB-A
75002-B.....(pg.15)......... WHB-B
75003-C....(pg.15).........WHB-C
75004-D....(pg.15).........WHB-D
75005-E....(pg.15)......... WHB-E
75006-F....(pg.15)......... WHB-F
75000-S....(pg.14)............CL-AA
75001-S.....(pg.14).............. CL-A
75002-S.....(pg.14).............. CL-B
75003-S....(pg.14).............. CL-C
75004-S....(pg.14).............. CL-D
75005-S....(pg.14).............. CL-E
75006-S....(pg.14).............. CL-F
WADE TO MIFAB
TRAP SEAL PRIMERS
WADEMIFAB
2400-S.........(pg.5).....MI-TSP-1
2400-T..........(pg.5).... MI-TSP-2
2400-MF.. (pg.5).............MI-DU
2400-M..... (pg.11)........... MI-750
2400-P..... (pg.11)........... MI-750
WATER HAMMER ARRESTORS
WADEMIFAB
5................ (pg.15)......... WHB-A
10............... (pg.15)......... WHB-B
20.............. (pg.15).........WHB-C
50.............. (pg.15).........WHB-D
75............... (pg.15)......... WHB-E
100............ (pg.15)......... WHB-F
5-P............. (pg.14)............. CL-A
10-P........... (pg.14)............. CL-B
20-P........... (pg.14)............. CL-C
50-P.......... (pg.14)............. CL-D
75-P........... (pg.14)............. CL-E
100-P........ (pg.14)............. CL-F
WATTS TO MIFAB
TRAP SEAL PRIMERS
WATTSMIFAB
TSP...(See MPB-2012). MI-TSP-1
TSP-1.(See MPB-2012).MI-TSP-2
A-200.............. (pg.5)..... MI-TSP-2
A200-S........... (pg.5)..... MI-TSP-1
A200T............. (pg.5)..... MI-TSP-2
MS-810........... (pg.5)..... MI-TSP-1
WATER HAMMER ARRESTORS
WATTSMIFAB
SG-050......... (pg.14).......... CL-A
SG-75........... (pg.14).......... CL-B
SG-100......... (pg.14).......... CL-C
SG-125......... (pg.14).......... CL-D
SG-150......... (pg.14).......... CL-E
SG-200......... (pg.14).......... CL-F
SG-A............ (pg.15)...... WHB-A
SG-B............ (pg.15)...... WHB-B
SG-C............ (pg.15)......WHB-C
SG-D............ (pg.15)......WHB-D
SG-E............ (pg.15)...... WHB-E
SG-F............. (pg.15)...... WHB-F
SS-A............. (pg.15)...... WHB-A
SS-B............. (pg.15)...... WHB-B
SS-C............. (pg.15)......WHB-C
SS-D............. (pg.15)......WHB-D
SS-E............. (pg.15)...... WHB-E
SS-F............. (pg.15)...... WHB-F
ZURN LIGHT COMMERCIAL
TO MIFAB
TRAP SEAL PRIMERS
ZURNMIFAB
TP2920.........(pg.5).....MI-TSP-1
TP2922-PC.... (pg.11).... MI-700
TP2923-PC.... (pg.11).....MI-701
TS2900-IP2.(See MPB-2012).TS1002
TS2900-IP3.(See MPB-2012).TS1003
Z1020.......... (pg.6,7)......MI-100
Z1021.......... (pg.11)........MI-750
Z1022-SF.... (pg.5).....MI-TSP-1
Z1022-IP...... (pg.5).... MI-TSP-2
Z1022-SFU..... (pg.5).. MI-TSP-3
Z1023........(pg.12).... MI-600-50
WATER HAMMER ARRESTORS
ZURNMIFAB
WH2950-AA... (pg.14)..... CL-AA
WH2950-A..... (pg.14)........CL-A
WH2950-B..... (pg.14)........CL-B
WH2950-C..... (pg.14)........CL-C
WH2950-D..... (pg.14)........CL-D
Z1700-100...... (pg.15)....WHB-A
Z1700-200...... (pg.15)... WHB-B
Z1700-300...... (pg.15)... WHB-C
Z1700-400...... (pg.15)... WHB-D
Z1700-500...... (pg.15)... WHB-E
Z1700-600...... (pg.15)....WHB-F
Design and dimensions are subject to modification. Prices do not include applicable taxes. Visit www.mifab.com for the most recent product information.
24
MIFAB, Inc., 1321 West 119th Street, Chicago, Illinois 60643-5109, USA
All sales subject to MIFAB’s Terms and Warranties. Please refer to inside front cover.
Toll Free: 1-800-465-2736, Fax: 1-773-341-3049
sales@mifab.com Canada Toll Free: 1-800-387-3880
TSP-2013
NOTES
Design and dimensions are subject to modification. Prices do not include applicable taxes. Visit www.mifab.com for the most recent product information.
MIFAB, Inc., 1321 West 119th Street, Chicago, Illinois 60643-5109, USA
All sales subject to MIFAB’s Terms and Warranties. Please refer to inside front cover.
Toll Free: 1-800-465-2736, Fax: 1-773-341-3049
sales@mifab.com Canada Toll Free: 1-800-387-3880
25
TSP-2013
MI-100
MI-DU-625
MI-TEMP
Trap Seal Primers and Water Hammer Arrestors
LIT-062
MIFAB, Inc. 1321 West 119th Street, Chicago, Illinois 60643-5109, USA Toll Free 1-800-465-2736, Fax 1-773-341-3049 www.mifab.com
Design and dimensions are subject to modification.
Prices do not include
applicable
taxes.1-800-387-3880
Visit www.mifab.com for the most recent product information.
sales@mifab.com
Canada
Toll Free:
MIFAB, Inc., 1321 West 119th Street, Chicago, Illinois 60643-5109, USA
Toll Free: 1-800-465-2736, Fax: 1-773-341-3049
sales@mifab.com Canada Toll Free: 1-800-387-3880
All sales subject to MIFAB’s Terms and Warranties. Please refer to inside front cover.
26
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project