Instructions For Fitting VARILIGHT Intelligent Trailing Edge Touch

Instructions For Fitting VARILIGHT Intelligent Trailing Edge Touch
INSTALLERS – PLEASE LEAVE
THESE INSTRUCTIONS WITH YOUR
CUSTOMERS TO KEEP FOR
FUTURE REFERENCE
www.varilight.co.uk
Instructions For Fitting VARILIGHT Intelligent Trailing Edge
Touch / Remote Control Dimmerswitches
Please record the batch number
printed on the side of the plastic
moulding on the rear of the product.
This will assist us in providing any
technical support you may require.
BATCH NO:
J_I
Reg. 820
For Software
7A & Later
Thank you for choosing a VARILIGHT V-Pro Eclique intelligent programmable touch/remote control dimmerswitch. Use only on an electricity supply of 200-250 volts AC.
IMPORTANT: Read “Loading Advice” section below before
OPTIMISING THE PERFORMANCE OF YOUR DIMMERSWITCH
installing this dimmerswitch.
1. CHOOSE THE CORRECT DRIVING MODE
V-Pro dimmers are set to run in trailing-edge mode 1 by default. This
> MODE 1: When you first install the dimmer switch it will automatically default to trailing-edge
Versatile mode is suitable for most types of lighting, including many
mode. This mode is the best one for most types of lighting.
dimmable LEDs. It is also gentler on the load. Some lighting loads,
For certain lighting loads you may be able to improve the dimming performance by changing to:including some types of LED, perform best with leading-edge control.
> MODE 2: Leading-edge mode for some LED lamps
This dimmer can easily be set to run in leading edge mode by
> MODE 3: DigiFlux® mode for DigiFlux® Dimmable CFLs and some external LED drivers
Following the instructions “Choose the Correct Driving Mode” on the
CHANGING
THE DRIVING MODE
right.
1. Switch on, then press and hold the touch button on the dimmer for 15 seconds. During this time
The Eclique master dimmer is suitable for 1-way circuits. For 2-way
the lights will cycle up and down. After 15 seconds the lights will turn off.
(or multi-way) circuits, use an Eclique master dimmer with one or
2. To select MODE 2, press the touch button 4 times (each press causes the light(s) to turn off/on)
more Eclique dimming slave units. Eclique touch/remote dimmers
OR To select MODE 3, press the touch button 6 times (each press causes the light(s) to turn off/on)
cannot be used in conjunction with conventional switches in a 2-way
OR To select MODE 1, press the touch button 2 times (each press causes the light(s) to turn off/on)
circuit. Use only on an electricity supply of 216-253V~. Eclique
3. The lights will flash once, twice or three times to confirm the mode that has been selected.
dimming slaves are touch control only. Remote control is only
2. ADJUSTING THE MINIMUM BRIGHTNESS (to utilise the full dimming range of your lights)
possible for the master unit.
Tap the touch button 6 times, roughly once per second (each tap causes the light(s) to turn on or
This product complies with European Safety Regulations (IEC 669-2-1
off). After 6 taps, wait until the lights step up and down and then go off. Then tap the touch button 6
or BSEN60669-2-1) when used in lighting circuits containing MCBs
more times. The lights will come on at a medium brightness and step down to show the 8
(miniature circuit breakers). These can be rated at 6A, 10A or 16A
brightness settings you can choose as your minimum. Each further tap steps through the 8 settings
(preferably 6A for lighting circuits). Your guarantee is not affected if
available in sequence. At your chosen brightness, usually the lowest brightness setting where the
you have an older lighting circuit protected by fuse wire links.
lights do not flicker, stop tapping the button. After 5 seconds the dimmer will step the lights up and
THIS SWITCH IS NOT SUITABLE FOR
down to confirm it has saved this setting.
Non-dimmable fluorescent bulbs and tubes;
RESTORE FACTORY SETTINGS
Wire-wound or toroidal transformers;
To restore factory settings tap the touch button 6 times, roughly once per second (each tap causes
Electric motors.
the light(s) to turn on or off). After 6 taps on the button the lights will step up and down and go off.
THIS SWITCH IS SUITABLE FOR
Press and hold the touch button for at least 5 seconds. The lights will then come on and fade to off
Mains voltage incandescent GLS or candle-shaped bulbs;
to signal that the dimmer has been reset to factory settings.
Good quality dimmable electronic low voltage
OVERLOAD PROTECTION: This dimmerswitch is protected against overload. If an overload
transformers (including those requiring trailing-edge control)
occurs it will automatically turn off until the overload is removed and the dimmerswitch is
[see “Transformers" box on the right];
switched off and then switched back on again. However, if the dimmerswitch receives a total short
GU10 or similar good quality mains halogen bulbs
circuit it may be damaged beyond repair.
Dimmable CFLs
Most dimmable LEDs [see “Dimmable LEDs” box on the right]]
TRANSFORMERS:
Always Observe The Recommended Maximum Loads
Use only with quality dimmable electronic transformers. For optimum performance choose
[Please also refer to "Overload Protection" box on the right]
VARILIGHT transformers*.
To calculate load, add the VA ratings of the transformers (not the wattage of the bulbs). Choose
Dimmer
V-Pro
V-Pro
V-Pro
V-Pro
transformers with a maximum rating close to their lamp load (eg. Use a 50VA, 60VA or 70VA
Series
Eclique
Eclique
Eclique
Eclique
transformer to control a 50W low voltage bulb).
1 Gang
2 Gang
3 Gang
4 Gang
Max.
Max.
Max.
Max.
N.B. Certain transformers may not behave according to their power rating when used with a
Lighting
Load
Load
Load
Load
dimmer. An overload will result in the dimmer turning itself off. If this happens, change your
Type
Per
Per
Per
transformer(s) (VARILIGHT transformer(s) recommended); or remove one (or some)
Gang
Gang
Gang
transformer(s) from the circuit; or choose a higher rated dimmer instead.
* If a transformer appears as a highly inductive load, e.g. Wire-wound or toroidal transformers, the
dimmer will not work. To protect itself it will turn off within 1 second.
Incandescent
300W
200W
300W
200W
Mains Halogen
250W
150W
250W
150W
Low Voltage
Halogen
250W
150W
250W
150W
Eco Halogen
250W
150W
250W
150W
LED
[Refer to text in “Dimmable LEDs” box on
the right.]
CFL
Use 1 to 6 Digiflux CFLs* Use MODE 3:
DigiFlux Mode [See box: “Choose the
Correct Driving Mode” above right.]
ADVICE ON CHANGING LIGHT BULBS:
Always turn off the mains power when light bulbs controlled by your Eclique dimmer are replaced. If
you change the type of light bulb then restore factory settings as described above.
DIMMABLE LEDs
Always choose LEDs that are described as “dimmable” and for the best performance choose
dimmable LEDs from established brands. We cannot guarantee that all LEDs labelled as
“dimmable” can actually be dimmed satisfactorily. The maximum load of dimmer should be derated for LEDs. See below or check www.varilight.co.uk/led for latest advice on loading.
Maximum and minimum loads will vary according to make and type of LED. Refer to LED
manufacturer for specific loading information. Generally 1 to 10 LED lamps per gang will perform
well per dimmer circuit. A maximum load of 100W for LED is recommended. The dimming
performance of dimmable LEDs may be improved by following the steps outlined above under the
heading “Changing the Driving Mode”.
FITTING YOUR DIMMERSWITCH:
Read the instructions below carefully. Incorrect installation may damage the dimmer beyond repair. In case of any doubt or difficulty consult a qualified electrician.
1. Switch off at the mains, then remove the existing switch and disconnect the wiring from the switch terminals at the rear, taking note of the present wiring of the switch
and the marking on the terminals. Where there are two or more wires together in the old switch, they must be kept together in the dimmerswitch.
2. Ensure that any wall box is free of plaster lumps or projecting screw heads. Dimmerswitches on single-sized plates can be fitted to wall boxes having 60.3mm screw
fixing centres and those with double-sized plates to wall boxes with 120.6mm fixing centres. Most models can be fitted into a box with a minimum depth of 25mm. A box
having 4 fixing lugs cannot be used without modifying it. The top and bottom lugs must be broken off or bent flat.
3. To connect the wiring for 1-way or 2-way circuits refer to the diagrams overleaf under the heading "Typical Lighting Circuits". Take care that no bare wires project out of
the terminals. Keep wires together in a terminal if they were together in your old switch.
4. Dimmerswitches having a metal plate must be earthed by means of the earthing point on the dimmer.
5. After connecting the wires screw the dimmerswitch gently into the wall box so that the front plate is not distorted or cracked. Do not trap the wiring between the rear of
the dimmer and the back of the wall box.
6. Once installation is complete. Switch on the mains supply and switch on the dimmer.
1-Way, 2-Way and Multi-Way Circuits
In 1-way lighting circuits the light(s) are controlled by one switch. This dimmer should replace that switch. The live wire must be connected to the
terminal marked "LIVE" and the "load" wire to the terminal marked "LOAD". To fit 2, 3 or 4-gang dimmers treat each group of terminals at the back of
the unit as a separate dimmer. You may also need a short length of wire to connect together the "LIVE" terminals if only one live wire is present
For 2-way or Multi-way circuits (where the light(s) are controlled by more than one switch) use this dimmer and any number of VARILIGHT Eclique dimming slaves (total
cable length from the master to the last slave should be no more than 50m) following the wiring diagrams overleaf. It is not possible to use a conventional switch in
combination with this type of dimmer. Follow the same wiring as for 1-way circuits with three (or two) wires linking each slave using the “LOAD” terminal, “S-LINK” terminal
and (optional) “LIVE” terminal. (Please see below). For more information please refer to the wiring diagrams overleaf.
Fig 1. Wiring for 1-Way Circuits
Fig 2. Wiring for Multi-Way Circuits
Fig 3. Alternative Wiring for Multi-Way Circuits
OPERATION OF THE SWITCH
To initialise the dimmer, press the circular button on the front of the plate once for 2 seconds. The dimmer will respond by making the light(s) brighter. A single press
will now turn the light(s) on or off. To dim the lights, keep contact with the button until the desired light level is reached. While contact with the button is maintained, the
brightness will cycle up and down. To change the direction of the dimming cycle release and then press the button again. When the brightness reaches the level you
require, remove contact with the button.
Dimmers are pre-programmed to respond to button 1 and button 8 on the VARILIGHT remote control handset (purchased separately). Alternatively, dimmers can be
re-programmed to respond to any other button (2 to 7) on the VARILIGHT remote control handset or a spare button on many other remote control handsets. [* See box
below: USING YOUR OWN REMOTE CONTROL HANDSET]. If there is a button that you do not currently use then you may be able to use it to control the dimmer by
following these steps carefully (do not omit step 3):1. To set the dimmer into learning mode tap the button 6 times, roughly once per second (each tap
causes the light(s) to turn on or off). After 6 taps on the button the lights will step up and down and go off.
2. Within 15 seconds and from a distance of less than 1 metre (3 feet) away, pointing directly at the button
on the dimmer, briefly press the chosen button on the handset. The light(s) will turn on and turn off.
3. To confirm your choice, briefly press the same button again. If the programming has
been successful, the light(s) will turn on and turn off. The lights then step up and down once
to confirm. Try controlling the dimmer with the remote control. If it does not respond return to
step 1 above and try again. If the problem persists, try a different button, a different remote
control unit or purchase the dedicated VARILIGHT controller.
4. You can now use this button on the remote control to operate the dimmer. As with the touch button, a single touch on the remote control button will turn the light(s) on
and off. Holding the button down will make the brightness cycle up and down. To change the direction of the dimming cycle remove contact and then press the button again.
Release contact from the button when the desired light level is reached. The dimmer can still be operated using the touch button.
5. For 2- gang models, repeat steps 1 to 4 for each button, teaching each one a different button so you can control each one separately.
You can change your choice of control button by following steps 1 to 4 again at any time.
* USING YOUR OWN REMOTE CONTROL HANDSET: If you have a spare button on an existing remote control handset then you may be able to use it to control this
dimmer. Not all handsets are compatible with VARILIGHT dimmers but many are. If you try and program the dimmer using your own handset and find that it does not
respond then you will need to buy a VARILIGHT YRC8 handset (standard control) or YRE8 handset (for advanced control with LightScene™) instead. In some cases
the dimmer may appear to learn the signal from your own handset but then respond to other handsets as well. In this case please use the reset function to restore
factory settings and buy a VARILIGHT handset instead. For best results, always choose a VARILIGHT handset.
VARILIGHT HANDSETS:YRC8 – Our standard handset allows control of up to 7 dimmers. Button 8 can be used to turn all the lights on or off. The dimmers will remember the level they were at
when switched off and so the previous light levels can be recalled using button 8.
YRE8 - THE ECLIQUE™ HANDSET FEATURING LIGHTSCENE™
CHOOSE THE ECLIQUE™ HANDSET FOR ENHANCED LIGHTING CONTROL
www.varilight.co.uk/lightscene
Access a host of additional features from your Eclique™ dimmers
• Control up to 4 lighting circuits from a numbered button
• Turn all the lights on or off using a master button
• Lightscene™ - Combine different light levels in each circuit to create a lighting scene in any room (e.g. for cooking, dining, reading, movies, etc.)
• Save your 4 favourite lighting scenes and recall any one at any time
FREQUENTLY ASKED QUESTIONS
1. Is it normal for the dimmer to be warm to the touch even when the lights are off? A small current passes through the dimmer even when it is off to maintain its
memory. This can cause the dimmer to feel warm to the touch.
2. Should I be concerned if the dimmer is very warm during use? The dimmer will become warm during use. The more lights the dimmer is controlling, the hotter it will
become. On its maximum load the dimmer can become very warm. As long as you have not overloaded the dimmer, this is no cause for alarm. If the dimmer is overloaded
it will turn the lights down or off.
3. What happens if I have a power cut? If for any reason the power is lost to the dimmer, it will still remember the button you have programmed it to respond to.
4. Why won’t my dimmer respond to the remote control? Check batteries are not flat and are connected properly to the contacts in the casing. Make sure you point the
remote control in the direction of the switch and that there is nothing in the way to block the signal. Move closer to the switch. For best results use the VARILIGHT handset.
In some cases there may be interference between LED lamps and remote control handsets. If you experience problems, follow the “RESTORE FACTORY SETTINGS”
guidelines above.
5. The dimmer keeps turning itself off.
(a) The dimmer may be doing this because it is grossly overloaded. Use lower wattage bulbs (or dimmable electronic transformers) to reduce the load. Otherwise use the
dimmer elsewhere on a suitable load.
(b) The dimmer will also turn off if you are trying to control an unsuitable inductive load (such as a wire-wound or toroidal transformer). In this case change the load to a
dimmable electronic transformer.
6. The dimmer responds to other buttons on my remote control handset(s). Repeat the programming procedure above, paying particular attention to holding the
handset less than a metre (3 feet) from the front of the dimmer and pointing directly at the lens when you press your chosen button. Be sure to complete the programming
procedure by confirming your choice as described at stage 3 of the programming instructions. For best results use the VARILIGHT handset.
7. How many slaves can be used with a master unit in a multi-way circuit? Any number of slaves can be used as long as the total cable length from the master to the
last slave is less than 50m.
GUARANTEE
In case of any defect, return the dimmer to our service department. Varilight undertakes to repair or replace, at its discretion, goods which have become defective within 12
months of purchase, solely as a result of faulty materials and workmanship, provided that:a) The unit has been correctly fitted according to the instructions and has not been used with an incompatible load, fluorescent tubes, or overloaded beyond its rating, and
has only been used on a 200-250V a.c. power supply.
b) The dimmer module has not been tampered with or taken apart.
c) The unit is securely packed and safely returned to Service Department, Carylls Lea, Faygate, Horsham, West Sussex, RH12 4SJ (Tel. (01293) 851584) together with a
letter stating the guarantee registration number below, the date and place of purchase, the type and wattage of the lighting or other load being controlled and the details of the
fault. This guarantee states Varilight’s entire liability, which does not extend to cover consequential loss or damage or installation costs arising from a defective product. The
guarantee does not apply to problems arising from any incompatibility between your lamps and the dimmer switch. This guarantee does not in any way affect the statutory
rights of the purchaser and is offered so that you may have the benefit of our technical facilities.
GUARANTEE REGISTRATION NUMBER 820.