Field Phone System Manual, v1.0
Field Phone System User's Manual
Version 1.0
19 September, 2016
by
SoftBaugh, Inc.
Find additional information at:
softbaugh.com/fieldphone
Also participate in our field phone forum, linked from that site.
This manual is written to assist the novice user in effectively using the field phone system, as well as provide
advanced users with additional details to help them make the most of the system's features. All users should read
this manual in detail to achieve the most from this highly flexible system.
Whether used by a small family group, such as a family business or farm, or by the busy zombie defense team on
the go, we recommend assigning someone to specialize in the care and configuration of the field phone system.
There is a good chance that some feature of interest can be either used directly, or created from a modified
version with reasonable effort. Your appointed specialist should read this manual often, and participate in our
user's forum, to discover something new about the available features, charging options or battery care, as well as
providing feedback so that we can improve future versions or products to better suit your needs.
Some configurations have been tested for FCC compliance and are noted herein, but due to the flexibility of this
system, some technically proficient users may wish to create homebuilt modifications. See the relevant sections
of this manual for guidance on maintaining FCC compliance.
Disclaimer: The field phone system is for hobbyist use and is intended for educational purposes. Some system
components use or create high voltages or supply fixed currents and could present a hazard if wet, as does any
telephone line. Use at your own risk and ensure that children operate the system only with adult supervision. Do
not lick or ingest any system component. Water or zombie drool can damage system components. Zombies may
become entangled in wiring and present a hazard to the operator.
Field Phone System Manual v1.0
19 September 2016
Field Phone System Overview
The field phone host module allows the provision of a small, wired, voice communication network using off-theshelf corded telephones and telephone wiring, but completely separate from the public telco network. This
manual illustrates how to configure the field phone host module in a variety of typical installations.
A generic installation is shown below:
Figure 1: Field Phone System Components
The essential elements of a field phone system installation are as follows:
- Two or more normal, wired telephones. These can be configured to operate on up to two separate lines, or
bridged to be one larger network. The master telephone should be, but is not required to be, a two-line phone
with local conference feature. If a two-line conferencing master is not available, a jumper setting on the field
phone board can serve this role.
- The Field Phone Host Module (FPHM), which powers the system via an 1100 mAh Lithium Iron Phosphate
(LiFePO4) battery in the 18650 format. This battery will operate a full set of phones for many hours, and can be
charged from a variety of power sources. The field phone host module also contains an audio connector to allow
conversations to be monitored or recorded for increasing proficiency of zombie-defense teams.
- Optional Ring Interface Modules (RIMs), which are inserted into the line to provide ring indication at the
remote, non-master phones. Much more on ring indication later, but the central idea is to provide silent or quiet
ring indication to facilitate tactical use of this system against zombies.
- Wiring to connect all these components. Normal 4-wire (2-line) telephone cables are used, although if ring
indication is not desired, 2-wire (1-line) telephone cables can be used to connect the remote phones to the field
phone system. The master phone should always be a 4-wire cable. Either straight-through or reversed wiring can
be used, system options allow these to be properly configured in hardware.
We will refer to this diagram in later sections to illustrate proper configuration and use of system components,
but first, a note from the regulatory compliance people...
Page 2 of 23
Field Phone System Manual v1.0
19 September 2016
FCC Verification Statements
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Later sections of this manual will discuss exact configurations verified for compliance, along with notes to assist
a technically proficient user to maintain FCC compliance when experimenting with home-built configurations.
Field Phone Host Module Overview
The fundamental component of a field phone system, the Field Phone Host Module (FPHM), is shown below in
diagram form:
Figure 2: Field Phone Host Module
Five RJ11 (4-wire) phone connectors are along the top, split into two lines (L1 and L2), with a master connector
(M) sitting astride both lines (this arrangement gives a large amount of flexibility in which kinds of phones can
be used as well as how to configure single-line or dual-line operation). The recommended options for two-line
and single-line operation are detailed in a later section of this manual.
Page 3 of 23
Field Phone System Manual v1.0
19 September 2016
The FPHM derives its operating power from an 1100 mAh LiFePO4 battery in the 18650 format. FPHM units
ship with this battery, and with proper care and diligent charging, should last for years of continuous use. A
single charge will operate the field phone system for hours of continuous communication, days if the phones are
only used intermittently. The exact length of time a charge will last depends on the exact phones used, the
lengths of wire used, and the patterns of use.
Charging power in the 6 volt to 30 volt range can be supplied via the power jack (P) or the terminal block (T).
This arrangement gives a large amount of flexibility as to powering the field phone system. We will discuss the
charger, external power options, FCC compliance tips, and proper battery care in more detail in later sections.
The 3.5mm stereo audio connector (A) allows both lines (L1 on the right channel and L2 on the left) to be
monitored or recorded by an external PC. Under some circumstances, audio from an external PC can also be
injected onto the lines. External software running on a PC is necessary to condition the audio and capture the
signals. Operation of the audio interface is a bonus feature that is beyond the scope of this manual.
The field phone system does not support the normal telco 48v ring signaling. This feature is by design, as
zombie ears, evidenced by various popular documentaries on the subject, tend to be particularly tuned to the
sound of telephones ringing while participating in rampages. Rather than a normal telephone ring, the field
phone system supports silent (LED) or quiet (piezo) ring indication by using ring interface modules for the
remote phones, as discussed later. The FPHM provides individual ring indication LEDs (not shown in the figure)
and a shared piezo (Z) for the master phone, as well as switches (S1 and S2) to ring the remote phones.
The field phone system contains eight LED indicator lights, grouped into three categories. Normal status lights
are green, ring indicators are yellow, and fault indicators are red. These are summarized in the following table.
Table 1: Indicator Lights
Name
Color
#
Location
Purpose
PWR ON
Green
D24 Mid-Lower
Right
Indicates that the board is powered, either from an external
supply, the LiFePO4 battery, or both.
DC IN
Green
D2 Upper Right
Indicates that an external charging supply has been provided at
the power jack (P) or the terminal block (T).
CHG
Green
D4 Bottom Right
The battery is charging when lit. See the section on charging.
(Line1, not
marked)
Yellow
D7 Bottom Left,
Near SW1
Ring indication for Line1.
(Line2, not
marked)
Yellow
D6 Bottom Left,
Near SW2
Ring indication for Line2.
REVERSE
BATTERY
Red
D19 Lower Left
Indicates that the battery is in backwards. Remove and insert
correctly.
SHORT
Red
D12 Lower Left
Indicates that the buzzer circuit is shorted. Check wiring.
FAULT
Red
D3 Bottom Right
Indicates a failure while charging the battery. May appear after a
few minutes of attempting to charge an undercharged battery.
See the section on battery faults.
Page 4 of 23
Field Phone System Manual v1.0
19 September 2016
Finally, as indicated in Figure 2, the jumper block (J) allows the user to configure various system options. These
options, summarized in the table below, will be discussed in later relevant sections of this manual.
Table 2: Jumper Block Options
Name
Pos When Off
When On
JOIN LINES
1
Lines are separate, can be conferenced
with a 2-line master phone. Line1 phones
and Line2 phones are on separate circuits
unless conferenced.
Lines are joined at the FPHM, and all
phones talk to all other phones. A single
line phone can be used in the master
location. See also BZ JOIN below.
MPPT/UVLO
2
No analysis of charging input.
Applies a maximum-power-point tracking
algorithm to the incoming charging source.
Also performs an under-voltage lockout,
halting charging if the input voltage falls
below a programmed level.
BZ ENABLE
3
FPHM buzzer does not sound when either FPHM buzzer will sound if either line is
line rung.
rung.
BZ JOIN
4
Ring indication is separated between the
lines.
Use with JOIN LINES or master phone
conference feature to enable ring
indication across all phones.
Ring Interface Module Overview
Since the field phone system does not support normal telco ring, a ring interface
module is used if call indication is desired at a remote phone. A diagram for this
optional ring interface module (RIM) accessory is shown to the right. Each RIM
supports three line connectors (Line, Rev in the diagram for Reverse and Phn in the
diagram for Phone), a single jumper (J) to enable the call indication buzzer, a single
pushbutton (S) to call other units, and a piezo buzzer (Z). As mentioned previously, the
master phone does not use a ring interface module as the master's switches and piezo
are on the FPHM itself. Not shown on the diagram is the silent ring indication LED.
Figure 3: Ring
Interface Module
The Phone connector is used to attach a phone to the RIM, while the upstream FPHM is connected to either the
Line or the Reverse connector, depending on whether straight or reverse wiring is used. A later section will detail
the use of these connectors when using either normal telco wiring or custom field wiring, and some usage ideas
for remote stations without telephones.
Page 5 of 23
Field Phone System Manual v1.0
19 September 2016
Field Phone System Installation
The basic field phone system ships with the core items shown in the photo below:
One Field Phone Host Module (top left)
One SB6VF AC adapter, with EMI ferrite (top right)
One 1100 mAh LiFePO4 battery in the 18650 format (bottom left)
One common mode choke ferrite (bottom center)
One 0.01 uF EMI capacitor (bottom right)
The first three items create the minimally functional core system which is FCC-compliant and capable of both
battery operation and charging from external power from AC sources.
The last two items are included to facilitate optional external DC charging in an FCC-compliant manner. A later
section describes the installation of these optional components in detail.
The field phone system is capable of more advanced operation than that provided by the basic core system.
Optional bundles include the above, plus one or more 4-conductor cables, ring interface modules, and wall
adapters for custom wiring. This section will describe the basic setup for the field phone using the core items
only. Later sections will describe adding these optional materials to the basic setup.
In addition to the SoftBaugh-supplied components in either the core system or optional bundles, two or more
user-supplied normal wired telephones are required. These may be one-line or two-line phones, but it is
recommended that the master phone, at a minimum, be a two-line phone. Additional cabling may be required; 4conductor cable is preferred if ring indication is to be used.
Now, we describe how to get the core field phone system up and running.
Page 6 of 23
Field Phone System Manual v1.0
19 September 2016
Mount the FPHM Board (optional)
The FPHM can be used in a mobile application and carried from site to site, but it is mainly designed to work in
fixed installations such as between nearby buildings or other fixed locations. For fixed installations, it may be
preferable to mount the FPHM to a wall so that it remains out of the way yet still accessible for the ring pushbuttons.
If desired, the FPHM board can be mounted to a flat surface using screws at the four corner mounting holes. A
non-conductive surface, such as wood, is preferred. Wood is more desirable than plastic because the slight
conductivity of wood prevents a buildup of surface charge while plastic can get the zappies (technical term for
Electro-Static Discharge, or ESD). If it is necessary to mount the FPHM board to a metal surface, be sure to use
some spacers beneath the FPHM to keep the electronics from contacting the metal and shorting out. We have
supplied the FPHM with 4/40-threaded standoffs to allow it to just sit on a bench by default.
Configure the FPHM Jumpers
For this installation, start with all jumpers removed with the exception of the BZ
ENABLE jumper. You can hang them to the side of the jumper block, as shown to the
right. This is the default jumper configuration for the field phone host module.
Install the Battery
The next step in installing the field phone is to install the LiFePO4 battery. Insert this battery into the socket as
shown. Note that the positive terminal is to the left and matches the silkscreen on the board. If inserted correctly,
the green PWR ON light will illuminate:
If the battery is inserted backwards, the red REVERSE BATTERY light on the
bottom left corner of the board will illuminate, as shown to the right. Since
zombie defense can occur in less than optimal conditions, the board is protected
against damage in the event the battery is inserted backwards. Simply remove the
battery and insert it correctly.
Apply External Charging Power
To charge the battery, apply external power using the supplied SB6VF wall adapter, with the installed EMI
ferrite. Plug this adapter into the DC IN power jack (P) as shown below.
Page 7 of 23
Field Phone System Manual v1.0
19 September 2016
In this photo, the edge of the EMI ferrite is just barely visible at the top. Note that the green DC IN light, and the
green CHG light, will both illuminate. Because the LEDs themselves draw current from the battery, the charger
will typically remain on as long as external power is supplied, but the battery will be protected against
overcharging by the charger circuitry. If after a few minutes the CHG light goes out and the red BAT FAULT
light illuminates, then see the later section on battery faults for how to address this situation. Note also that the
DC IN light's brightness will track the input voltage. See the section on modification tips if you wish to adjust
this behavior. For maximum battery life, we recommend that the unit be left plugged in or otherwise constantly
charged, if possible, leaving the battery fresh for use during power outages or other emergencies.
Attach the Master Phone
Select a two-line telephone, and connect it to the master connector (M) using a 4conductor cable, as shown in the photo to the right. Be sure to connect the cable
to the L1+L2 connector on the master phone. This connector is also sometimes
labeled the “L1 OR L1/L2”, as it is in this case.
Attach the Remote Phone(s)
Determine whether you want to operate two separate lines or one single line. In this example below, we have
connected a phone to one of the Line 1 (L1) connectors using a 4-conductor cable.
Test the Phones
Set the master phone to Line 1. Then, pick up the handsets on each phone, and notice that you can now
communicate. If you can't hear anything, make sure the Master (M) and Line 1 (L1) connections are correct, as
well as having Line 1 selected on the master phone.
Page 8 of 23
Field Phone System Manual v1.0
19 September 2016
Inserting Ring Interface Modules
If you have purchased ring interface modules, you can add ring indication to your remote phones by inserting
them into the line between the FPHM and the remote phone.
If you are using stock 4-conductor telco wiring with RJ11 connectors on the end, then installing the ring
interface module will be fairly simple.
Disconnect the remote phone from the host cable, and using another cable, connect the
remote phone to the ring interface module at the phone (Phone) socket, as shown to the
right. For this connection, a two-wire cable can be used between the phone and the
ring interface module. And, this cable should be relatively short, since the ring
interface module should be within easy reach of the telephone during use. We offer an
optional 7' cable for this purpose, but many phones come with short 2-wire cables in
the box with them that will do just fine.
Next, insert the cable leading to the FPHM into the line (Line) socket on the ring
interface module, as shown to the left. If all the wiring is “straight-through”, then the
ring interface module should be working correctly.
If a “reverse” cable has been used, or if custom wiring has resulted in
a reverse condition, then this will be immediately apparent as the call
indication light will illuminate, as shown to the right.
If this condition is detected, then simply move the host cable from the line (Line)
socket to the reverse (Reverse) socket, leaving the phone connected to the phone (Phn)
socket. The call indication LED should now be dark, as shown to the left.
One of these configurations of the host cable should extinguish the call indication
light, as well as allow the attached remote phone to work. If neither configuration
works, check, repair or replace the host cable, particularly when using custom wiring.
To test the ring interface module, simply push the button (S) on the ring interface module, or the corresponding
line switch on the FPHM (S1 or S2) and you will see the call indication light illuminate on both the remote
phone's RIM and on the FPHM, and hear the buzzer (Z) sound on both the RIM and on the FPHM.
For silent, LED-only indication, remove the jumper (J) on the ring interface module and hang it to the side. Now
the buzzer will remain silent when the ring button is pressed on either end. For a silent indication at the FPHM,
remove the third jumper (BZ ENABLE). Note that a single buzzer (Z) is shared across both lines on the FPHM,
but the call indication lights will show which line is calling.
While we recommend using a two-line phone as the master, a one-line phone can still be used. As mentioned
before, the JOIN LINES jumper takes the place of a conference feature on a two-line phone, bridging both lines
at the FPHM. Similarly, the BZ JOIN jumper allows any ring interface module on either line to ring any other
ring interface module or the buzzer on the FPHM itself.
Page 9 of 23
Field Phone System Manual v1.0
19 September 2016
Installing the EMI Capacitor and Common Mode Choke
Since a deployed field phone system looks electrically like a giant antenna array, we have to prevent large
(relative to the currents in all other wiring) charging currents from causing unintentional radio emissions. After
all, you wouldn't want to accidentally cause submarines at sea to launch their missiles while telling your friends
about approaching zombies, would you?
If you decide to use an external battery charger and replace batteries in the FPHM rather than charging them with
it, then you do not need to install the EMI capacitor and choke, as no large charging currents are present at any
time (when not charging, the FPHM is exceptionally quiet radio-wise). You also do not need the EMI capacitor
and choke if you charge the FPHM's LiFePO4 battery using the provided SoftBaugh SB6VF AC adapter with the
attached ferrite blob near the barrel jack.
However, if you elect to charge the FPHM battery using an external supply (such as 12v battery or automotive
power), then FCC compliance requires installation of the provided EMI capacitor and choke.
The EMI capacitor must be installed at the terminal block (T), and the choke installed on the power leads, near
the terminal block, with five windings of the power leads passing through it. There are several ways to
accomplish this (including soldering the capacitor to the back of the terminal block pins in fixed installations),
but this section describes one neat and simple way to install these components to prevent unintentional radio
emissions while charging.
Installing the EMI Capacitor
The first step is to install the EMI capacitor. It is important to note that the capacitor is non-polarized, which
means that it is impossible to install it backwards. In other words, it doesn't matter which capacitor lead wire
goes to which terminal block screw.
In the picture to the right, we have accomplished
many things. First, we have removed the battery and
disconnected all power supplies. This is very
important! Then, using a screwdriver, we have
removed the terminal block screws in their entirety,
including their captive wire clamps.
Next, we have removed the capacitor (shown upside
down) from its handling tape and trimmed off about
a quarter of an inch of the leads. The exact amount
is not important as long as they are not too short.
You may want to test-fit the capacitor as shown in
the next photo, we want the leads to fit under the
wire clamps, but not extend beyond the edge of the
clamps too much.
Also, we have bent those leads to the side, and
inward, in a hockey-stick shape, to make them fit the
wire clamps better.
Page 10 of 23
Field Phone System Manual v1.0
19 September 2016
Next, as shown in the picture to the left, place the capacitor in the gap between
the battery holder and the terminal block. Lay the capacitor leads as shown, on
the outside of the screw holes, and to the left against the edge of the battery
holder. This position will allow the plus and minus signs to be seen in the gap.
Also, note the position of the PWR ON LED. Nudge the capacitor upwards
toward the phone connectors slightly to make sure this LED is not obscured. It is
not necessary that the capacitor be firmly against the board. Again, it is not
important whether you trimmed the leads exactly correct. As long as they make
reliable contact with the wire clamps, then that is good enough.
Now, reinstall the screws and their wire clamps, as shown to the right. These
clamps fit in any orientation, so just drop them in the holes and run the screws in
about half way.
This technique keeps the capacitor out of the way, which keeps the leads from
being damaged by handling, and eventually being broken off. It also keeps it out
of the way of the external power leads, which we will install next.
Installing the Common Mode Choke
After the capacitor is in place, we have to prepare the choke by running both the positive and negative lead wires
through the hole five times. We have provided two examples of this process.
The first example, shown to the left, uses solid core
wire. This is a length of twisted pair taken from a
section of Ethernet cable. We happened to choose the
brown and white pair, but any pair will do. For our
purposes here, the twist in the wire is helpful for
handling, but not required. You could also just as
effectively use two individual wires.
After stripping some insulation from the ends, wrap
the wire through the choke five times (known as
“turns”), as shown. Keep the amount of wire on the
FPHM side short, but not so short as to be
inconvenient to handle. The exact appearance is not
as important as the five turns. To make it all lay
neatly on the bench, we have chosen to have the
wires enter on the bottom and emerge on the top.
Then, insert the stripped ends under the wire clamps in the terminal block, this time to the insides of the screws.
Tighten the screws enough to keep the wires in the clamps, but not so much as to pinch and weaken them. Now,
re-install the battery and apply power. Note that both the power jack (P) and battery input terminals (T) are
reverse-polarity protected. If you hook up your external power source and the DC IN light remains dark, then
check to see if you connected the wires backward. The battery is now charging in an FCC-compliant way, as
shown below.
Page 11 of 23
Field Phone System Manual v1.0
19 September 2016
The second example, shown to the left, uses stranded
wire, which came wrapped in a jacket. This is
security system wire we removed from an old
building. The jacket is not strictly necessary, but it
does help protect the power leads from abrasion
against the choke. Because the wire and the jacket
are springy, we wrapped the entire thing in electrical
tape to keep the wires from unspooling. We also
tinned the leads with solder to help keep them from
wearing out, but in a pinch you don't need to.
To the right, we show the cable installed on the
FPHM and supplying power.
Because the FPHM only uses an average of 1.6 W to
charge, which is less than 150 mA at 12 volts, it is
acceptable to use small gauge wire over distances of
a few feet. You could also use larger gauge wire; the
size of the choke admits fairly beefy options. Just
make sure that you pass both wires together through
the coil the requisite five times.
You can also increase the robustness by adding
terminal connectors, heat-shrink tubing and so on,
but such things are beyond the scope of this manual.
Page 12 of 23
Field Phone System Manual v1.0
19 September 2016
Configuring Custom Phone Wiring
While the FPHM has been verified for FCC compliance using 7' cables for the master phone and between each
remote phone and its corresponding ring interface module, and 25' cables between each ring interface module
and the FPHM, other wiring configurations may be attempted as homebuilt options. If other wiring is desired,
the most convenient way to integrate custom wiring is the use of telco wall boxes, which convert custom wiring
into the RJ11 format.
These wall boxes come in a variety of styles and wiring configuration, but all of them feature one or more pairs
of wires. You will use the two center-most pairs of wires in your installation, the others can be ignored. The
photo below is an example of the wall box we provide, which has two pairs:
The pairs are determined by where they are attached to the connector on the bottom, and are reflected in the
ordering of the wires at the terminal screws above. This box reflects the standard telco wiring, which uses one
center pair, and then wraps that in another pair, one wire to either side of center.
Assigning Colors
In the standard telco format, the center pair is red-green. This is the pair shown at the top pair of terminal screws.
The next pair is black-yellow, the black being outboard of the red, and the yellow outboard of the green. It is
difficult to see this ordering in this and subsequent photos. But, the good news is you don't have to care much
about the ordering on the telco cables, all you need to care about is making sure the colors match up on each end
of the cable. These little adapter boxes are excellent for that.
In the field phone system, the red-green pair carries the voice signals, and the outer black-yellow pair carries the
ring indication signals. You can use practically any kind of wire between these adapter boxes and any number of
Page 13 of 23
Field Phone System Manual v1.0
19 September 2016
hops of any kind of wire in between adapter boxes. As long as the same string of wire is connected to the red
terminal on both adapter boxes, and a different string of wire is connected to the green terminal on both boxes,
and so on, then what you do in the middle between adapter boxes is entirely up to you.
For example, we have a test case installed which uses a variety of intervening cables, all of them recovered from
an old building. One leg of this sytem runs from one of these adapter boxes through an old 4-conductor security
system wire to an ancient telco punchdown panel, then through two twisted pairs on a scrap Cat5 Ethernet cable
to an unused telco post outside, then hops through an old underground and unused 25-pair telco conduit between
two buildings to another telco post outside the second building, then more Cat5 to another punchdown panel
inside, then back through more security system wire to another wall box on the other end inside the second
building. Standard 4-wire 7' telco cables then connect those wall adapter boxes to the FPHM and RIM,
respectively.
In between these hops in this example installation there are several varieties of color coding and wire types. At
each hop we label each wire according to its color in the field phone system (field phone red, field phone green,
etc.) and then maintain the standard on each end of each leg. So, when traversing one leg of Cat5, we might say
that orange is field phone red, orange-white is field phone green, brown is field phone black and brown-white is
field phone yellow. Yet, on another leg of Cat5, we might mix that up if other wire pairs are available or some of
them are damaged. Throughout all of these hops, the only thing that ultimately matters is that each signal winds
up connected to its corresponding color on the wall boxes at each end.
The most important thing is that each color must be assigned individually, and then that color consistently
applied from end to end. Otherwise, you can use practically any kind of wire, and connect them as you wish.
Custom Wire Examples
Now let's look at some examples of custom wiring using some salvaged cables, which is what you will
experience during a zombie rampage. Note that you can use any kind of wire or cable you can get your hands on,
these are only two examples.
Also, in an actual installation, before attaching the wires, you may want to fasten the
wall boxes to a convenient surface using the included screws. This is much harder to
do later without damaging something, so plan ahead.
The first example uses salvaged telco 4-conductor cable, which features solid wires.
These are the easiest kind of wire to use, as the colors match already, and the solid
wires are easier to bend and attach to the wall adapter boxes. In the photo to the right,
we have exposed the wire strands from the cable jacket (give yourself plenty of room
to work with), stripped about a quarter-inch from each end, and bent the ends into a C
shape. This C shape will make it much easier to get a good connection on the adapter
box screw terminals and keep the wire from squirting out from under the screw.
Next, place those bent ends under the screw terminals of the corresponding colors, and tighten enough to hold
them firmly in place, press all that up into the box, and snap the cover onto the box, as shown in the following
sequence of photos:
Page 14 of 23
Field Phone System Manual v1.0
19 September 2016
Never over-tighten the screws, as this makes the wire more likely to squirt out. These adapters have little walls to
help prevent that, but it still happens. Also, over-tightening can damage the wires, making them more likely to
break during use or handling, or strip the screw out completely. Only hand-tighten, never use a power
screwdriver.
Also, when placing the curved wires under the screws, always place the wires under the terminals so that the
curves are clockwise, the same as the direction the screw tightens. This will make sure that, if there is any slip,
that the wire tightens around the post rather than backing out. If you look closely at the red wire, you can see that
it slipped a bit, but tightened around the screw post anyway. If the curve had been in the other direction, the wire
would have been pushed off the post and mangled a bit.
The photos to the left and to the right show the use of
stranded wire, this time within fire-rated smoke alarm cable,
also taken from an old building. Note, in the inset, that the
stranded wire has first been twisted, and then bent into the C
shape. Also, the colors almost match, with a white instead of
yellow. These two colors have been connected, with all the
others connected to their respective mates. With stranded
wire, it is especially important to not over-tighten, as the
twisted strands can separate, become a mess and likely short.
Shorted Lines
Custom cabling always introduces more chance of accidentally shorting lines together.
If the inner pair of wires, the voice wires, becomes shorted, the phones will not work at
all. If the outer pair becomes shorted, either ring indication will sound continuously, or
the ring indication will be completely disabled, depending on the type of short. In the
latter case, the SHORT indicator light will illuminate, as shown to the left. If any of
these conditions happen, check the wiring for shorts.
Page 15 of 23
Field Phone System Manual v1.0
19 September 2016
FCC Compliance For Other Configurations
As a review, the field phone system has been verified for FCC compliance in these three configurations:
1. When running only from the onboard LiFePO4 battery, no charger operating.
2. When charging from the external SB6VF 6v AC/DC adapter, with attached Laird ferrite.
3. When charging from an external 12 volt battery, with attached EMI capacitor and common mode choke.
Other configurations fall outside the scope of our verification tests, but may qualify for FCC exemptions. The
FCC allows generous exemptions for homebuilt designs and modifications (not kits), mobile applications,
battery-only applications and special rules for emergencies. It is worth taking time to read the FCC Part 15 and
Part 68 regulations (available at fcc.gov). For purposes of finding the applicable regulations, the highest
frequency produced or used by the FPHM is 2 MHz. Also, ask an amateur radio hobbyist for help. Amateur radio
people tend to be very technically proficient, and will often have the right equipment to help you test your setup
for compliance issues, and can help find and fix a non-compliant modification.
In all cases, it appears that you can immediately buy a 1.5 dB margin simply by not using the 3.5 mm audio
cable. As mentioned before, the audio interface is irrelevant for most applications.
The basic principle is that if your equipment is causing interference, you have to stop using it. This also applies
to devices such as the FPHM which have passed FCC testing, as seen earlier in the FCC verification statements.
From a practical and tactical point of view, it is best to try to reduce your emissions even if FCC exceptions
would apply or no one is complaining, as needless emissions might interfere with your other electronic
equipment.
From our testing experience, most of the undesirable emissions will be around 140 MHz and 190 MHz when
charging (when not charging, the field phone system is exceptionally quiet from an emissions perspective). An
amateur radio expert can tune a receiver at those frequencies and listen while you plug the external power in and
out while using a partially charged battery. We recommend taking a baseline measurement (which may be
somewhat subjective) with an unmodified FPHM first, and then comparing results.
External Power Configurations
For all external power options applied at the power jack (P), we recommend the use of a ferrite. Our SB6VF uses
a Laird 28A0592-0A2, 511 ohm snap-on ferrite, which we offer for sale at our webstore and currently include
with each basic FPHM to enable a baseline FCC-compliant installation. However, we have had many high end
supplies fail compliance testing even with this or other ferrites attached.
For all external power options applied at the screw terminals (T), we recommend the use of the provided filtering
capacitor and common mode choke with five windings, as shown earlier.
Solar Configurations
Solar power presents a special set of circumstances, most of them regulatory. Testing a solar powered field phone
system for FCC compliance would be prohibitively expensive and introduce a set of uncertainties regarding solar
flux, time of day, weather, and so on. Even so, the results might only apply to that specific type of solar panel, as
Page 16 of 23
Field Phone System Manual v1.0
19 September 2016
solar panel designs can have wildly different parameters. A 10 W solar panel from one vendor might behave
dramatically different from a 10 W solar panel from another vendor.
As a result, we cannot currently bundle or market field phone systems with solar panels, although we can sell
field phone systems and sell solar panels, and even ship them in the same carton. If you decide to create a
homebuilt system using any particular solar panel, here are some tips to help you remain compliant.
First, everything discussed throughout this manual regarding using external power also applies for solar panels.
A prudent application would still use the EMI capacitor, and the common mode choke coil with five turns, as
well as taking baseline measurements. The MPPT/UVLO jumper on the field phone board is intended to help
with marginal panels or those being used on a cloudy day, as well as shutting down the charger when the input
power is insufficient, preventing additional noisy operation.
An important feature of solar panels is that they spend most of their operating life well below their rated power.
Although the FPHM only uses 1.5 W for charging, a 10 W panel would be appropriately sized. Remember that a
panel only performs as well as the least-performing cell, so if zombie pus is covering one cell, you may only get
a trickle of current out of the entire panel, although it might be near full voltage at no load.
An advantage of the FPHM charger design is that it accepts a large input voltage range. This is helpful when
selecting solar panels and reading the detailed specifications. Make sure that the full-sun solar panel voltage
(known as the Open Circuit Voltage, or VOC) does not exceed 30 volts, and that the maximum power point
voltage (often known as VMPP), is at least 9v, to allow some possibility for droop under less than optimal
conditions. Finally, a minimum of 3W, or better, 10W, allows the charger to operate continuously even if full sun
isn't available. After all, when defending against zombies, tossing a solar panel on the roof, in whatever random
orientation, may be the best you can do.
Another option for solar power (which is fully FCC compliant as-is provided the EMI capacitor and choke have
been installed) is to use a solar panel to charge a 12v battery via an inexpensive PWM controller (we prefer the
Outback Power models), and then charge the FPHM from that battery. Even a small 4.5 Ah battery, such as the
kind often found in a small PC UPS, can fully charge an FPHM in three or four hours, while only consuming
about ten percent of the capacity of that battery. A 100 Ah deep-cycle marine battery won't even notice.
Vehicular Configurations
One could mount the field phone system to a vehicle, and then charge from that vehicle's auxiliary power output,
such as a cigarette lighter circuit. Wired this way, the field phone system would only draw current from the
battery when the ignition is on (better, when the engine is running), but when the engine is off the field phone
system would operate from its LiFePO4 battery. And, this application could fall under the FCC exemptions for
mobile or vehicular applications, as well as a homebuilt modification, if not in direct compliance for running
from a 12v battery. Be sure to use the included EMI capacitor and common mode choke as described in detail in
a previous section. For 24v industrial equipment or truck battery arrays, check the aux voltage when the engine
is at full throttle. Ideally, this voltage should not exceed 28.8 volts, but some alternators run a little hot. If the
voltage is above 30v, such as might be found for a vehicle running AGM batteries, a technical expert can help
you install some upstream diodes to drop the incoming voltage some (see the section on modification tips,
below).
Page 17 of 23
Field Phone System Manual v1.0
19 September 2016
Battery Charging Options and Tips
Subject to the guidance in the previous section for FCC compliance, the field phone host module is designed to
accept a variety of charging inputs. This section details the technical aspects of various charging options, while
the next section provides information to help minimize the risk of a non-compliant homebuilt application.
When using any rechargeable battery, the lifetime of the battery is usually measured in charge-discharge cycles.
Typically, the deeper the discharge, the fewer cycles that can be expected from the battery. The meaning of
“deep” depends on the model and chemistry of the battery. A deep-cycle marine or golf cart lead acid battery
may tolerate many more 50% discharges than a starting battery, which only experiences a few percentage
discharge when cranking. This is why off-grid alternate energy applications typically use more expensive deepcycle batteries. Still, lead-acid is severely limited in lifetime cycles. Getting more than a year of daily deep
discharge service out of even the best deep cycle lead acid batteries is quite a feat, and two years is miraculous.
The LiFePO4 battery, on the other hand, can survive a large number of 100% discharges, well into the high
hundreds of cycles, even as much as a thousand cycles, and even then still have much of its nameplate capacity
available. Consult the appropriate datasheet for your specific battery for details, but the LiFePO4 is almost a
miracle battery for most applications.
The best way to ensure a long lifetime for your LiFePO4 battery is to keep it topped off constantly. Leaving the
FPHM attached to the wall supply, ready for service during power outages, is the best choice, but, of course, this
may not be practical for most zombie defense applications. In a pinch, you may have to use a variety of charging
sources to keep your batteries fresh.
To this end, we designed the FPHM so that it can be charged from any DC voltage source between 6 volts and 30
volts which is capable of supplying at least 1.6 watts. But, since nothing comes for free, one cost of this
flexibility (and reduced system cost to keep it affordable) is that the charging circuit on the FPHM exceeds FCC
limits for radiated emissions with some combinations of external power. We supply the SB6VF 6 volt, 300 mA
wall adapter with an attached ferrite, a power source which has been verified for FCC compliance for both
conducted and radiated emissions when used with the FPHM. Other sources, including high-end high-power
supplies, failed verification even with external ferrites.
As noted previously, the FPHM can accept charging inputs at either the power jack (P), in the case of the
SB6VF, or at the screw terminals (T), in the case of an external battery. As with the power jack, the screw
terminals can accept inputs between 6 volts and 30 volts, so this can support 6v and 8v golf cart batteries, 12v
batteries, or 24v industrial equipment arrays, including the over-voltages that typically result when charging
from alternators. To achieve FCC compliance, which we have tested with a 12v lead acid battery, the supplied
0.01 uF EMI capacitor must be attached at the screw terminals, with an external common mode choke wound
five times. This capacitor and common mode choke are supplied with each FPHM for installation by the end
user, as shown in an earlier section in detail. We will discuss other charging input options, including solar panels,
in the next section regarding FCC compliance for homebuilt applications.
Because the LiFePO4 battery can be replaced so easily, another option is to keep a supply of batteries charging,
and then simply replace batteries periodically, perhaps at each watch change in the case of zombie defense. Or, if
your charging source is dependent on periodic power, such as a generator budget each evening or solar panels
during the day, the batteries may not need explicit changing at all.
As mentioned previously, it is impossible to predict how long the battery charge will last. Long wires, and more
Page 18 of 23
Field Phone System Manual v1.0
19 September 2016
use of the phones, will both affect battery life, and lifetime available charge/discharge cycles. It would be best to
run some test exercises with your specific installation and get a feel for what is reasonable for you.
To protect the battery, the field phone host module will, on its own, shut down the relatively power-hungry
phone lines when the battery discharges to about 2.7 volts. At this point, the green power LED will still be lit,
and the ring interface features will still function, but the phones will be dead. If you encounter this situation, it is
time to change or charge the battery. A full discharge is usually rated at 2.0 volts, but the trip from 2.7 volts to
2.0 volts is a rapid descent; at 2.7 volts the battery will only have about five percent of its capacity remaining.
Once the phone lines go dead, the power LED will discharge the battery down to about 2.0 volts, the full rated
capacity of the battery, after another twelve or so hours. At this point, the power LED will be noticeably dimmer.
The battery will continue to discharge very slowly from this point. Actual damage will begin to occur around 1.5
volts, but it will take the FPHM a long time to reach this level as even the LEDs will draw very little current.
Even so, a battery left in the FPHM uncharged can eventually be damaged, and result in a battery fault when
charging is attempted. See the next section regarding handling battery faults.
Again, an undamaged LiFePO4 battery can tolerate hundreds of 100% cycles, more 95% cycles, and many more
80% cycles. Any of these cases represents years of daily cycles of full discharge. You may wish to run an
experiment with an actual installation and actual usage patterns to determine a typical schedule for replacing
batteries. With a freshly-charged battery, remove any external charging power, take all phones off hook, and
determine how long the phones run before the phone lines go dead. This is approximately the 95% discharge
point, and represents the worst case talk time. Given that batteries lose capacity as they age, 4/5 th of this time
would be a good maximum talk time goal over the first several hundred battery cycles.
Budgeting less continuous talk time than this 4/5th metric, and having spare charged batteries on hand, might
allow 1000 cycles or more each out of two batteries, rather than wearing out a single battery in 600 cycles. We
sell additional LiFePO4 batteries at reasonable prices on our webstore for this purpose. In general, if in doubt,
change or charge the battery. Unlike older battery technologies, LiFePO4 batteries are not subject to state-ofcharge memory effects or discharged storage issues, so you can't go wrong by charging or swapping it often.
For planning purposes, a fully-discharged battery will take about 3 to 4 hours to fully charge on the FPHM,
regardless of whether 1.6 watts or 160 watts are available at the input. You can purchase separate chargers to
keep a supply of charged batteries on hand, but be sure to get a charger designed specifically for LiFePO4
(which may include a LiFePO4 switch). We do not trust chargers which claim to be for any generic rechargeable
lithium battery or which claim to detect LiFePO4 among other options. A Li-Ion charger can destroy a LiFePO4
the first time it is used, and if the lowest-bidder firmware inside the charger decides your LiFePO4 is a Li-Ion or
lithium polymer, your battery is toast. Zombies can also smell burning batteries, we are told.
Finally, in a pinch, the FPHM can be operated solely from external power with no LiFePO4 battery at all. We
have not tested this mode for FCC compliance.
Battery Faults
If you forget to change, charge or remove the battery, it will eventually over-discharge. When this happens, and
charging power is reapplied, a battery fault may occur after a few minutes of attempted charging. This fault will
be indicated by illumination of the red BAT FAULT light, just to the left of the CHG light. If sufficient charging
power is applied, the phones will still work in this condition. If the battery is not severely damaged, after a few
Page 19 of 23
Field Phone System Manual v1.0
19 September 2016
hours of preconditioning, the fault light will go out and the battery will begin to charge normally. Mark this
battery for a profile test, as described in the previous section. Fortunately, unless you allow such over-discharges
on a routine basis, the battery should still be serviceable, with little or no degradation in its service life.
If the fault light does not go out after several hours of charging, then remove the charging source, remove the
battery, re-install the battery, and re-apply the charging source. The fault light may reappear after a few minutes
and then go out sometime later, as described above. If the fault light never goes out after many hours over many
attempts of this process, then the battery is probably ruined beyond recovery. We would feel comfortable using a
battery which required two or three such cycles of fault preconditioning. We would not feel comfortable using a
battery which failed ten such cycles. We would not rely on a battery which came back to life in the middle of that
range, but it would be fine for keeping around rather than operate the field phone system with no battery at all.
Mark it accordingly and use another battery for normal usage.
If you do find a battery that will not come back to life after ten or so fault preconditioning cycles, then mark it
but keep it around. There is a jumpstart process using a current limited (1-10mA) voltage source (3v) that can
sometimes work, but which is beyond the scope of this manual. The battery may not have very much useful
capacity at that point, but ten years into zombie-war we would rather try that than have nothing.
Practical Tips
We've done a lot to try to convince the reader to take good care of the battery, and battery care is important, but
fortunately, actual practice isn't likely to be that bad. A fixed installation, such as a farm, will likely have more or
less reliable or intermittent charging power, such as a solar-charged battery bank for incidental loads. A
command-post scenario, the most likely to experience more or less continuous phone use, will likely have shifts,
and it is sensible enough to assign battery management as part of the operational checklist. The scenario most
likely to experience long-term loss of charging power is a deployed zombie response field team, but that
situation is not likely to experience continuous phone use either. Even so, that team could easily solve the battery
problem by bringing a few spares, and LiFePO4 batteries are significantly lighter than other power alternatives.
It is possible to use the ring indications as a telegraph by using Morse or other codes, and thus greatly limit the
amount of talk time. Ring indication uses only a few tens of milliwatts, depending on the number of attached
stations and enabled buzzers, and that only when the button is pressed, while a full complement of phones in
constant use is more like a half a watt. Some simple ring indication codes can be worked out to indicate specific
messages or status updates, saving the talk time for essential communication.
The Morse or other code option introduces another possibility, and that is the use of the field phone system
without phones at all, and simply sending Morse code or pre-arranged signals between stations using ringinterface modules as telegraph terminals. Further, if a listening post were to remove the jumper on its ring
interface module, and cover its LED with a black marker to greatly reduce its intensity (or remove that LED's
drive resistor entirely as shown in the modifications section later in this manual), then signals could be sent to
the base FPHM unit with relative stealth. The listening posts could then have their wire and RIM sealed in a
clear bag, making their end relatively weatherproof.
Look forward to future options in this regard, including the application of quiet, piezo ear buds, if sufficient
interest exists. Or, a technical specialist may be able to wire additional options for you. Fortunately, the FPHM
backbone provides a lot of the technical foundation you can use as a building block for more advanced systems.
Page 20 of 23
Field Phone System Manual v1.0
19 September 2016
Modification Tips
Most users will never feel the urge to modify the field phone system at all. However, there are those who want to
modify things to better suit them. The purpose of this section is not to encourage modifications, but to inform
those who wish to create custom homebuilt designs. We expect that anyone attempting any modifications is
technically proficient, and assumes all risk for damaging their field phone system or operating in an FCC noncompliant mode. Be sure to read this manual in full to understand some fundamental principles, as we will not
repeat them here. A technically proficient user may also wish to have the manufacturer's datasheets for the
LT3652HV and LT3909 handy.
That said, if you blow up your field phone board for any reason, send us a photo and we'll treat its scorched
carcass as a 25% coupon toward a new one (single board only, no bundles, power supplies, EMI accessories or
batteries).
Adjusting LED Intensity or Usage
Some users may wish to modify the LED intensity, whether to make them brighter, dimmer, re-route their
display to a remote panel, or disable them entirely. Table 1 presented an overview of each indicator LED. The
corresponding resistors, and resistor values and voltages used to drive them, are shown in the table below. A
technical specialist can make suitable modifications to the board by using this table, if desired.
Table 3: LED Drive Resistors
LED
Color
D#
R#
Value
Source Voltage
PWR ON
Green
D24
R22
220
VBATT
DC IN
Green
D2
R1
1k
VIN
CHG
Green
D4
R5
220
VBATT
(Line1, not
marked)
Yellow
D7
R17
220
VBATT
(Line2, not
marked)
Yellow
D6
R16
220
VBATT
REVERSE
BATTERY
Red
D19
R15
330
VBATT
SHORT
Red
D12
R15
330
VBATT
FAULT
Red
D3
R4
330
VBATT
VIN: Charging voltage, 6v to 30v typical.
VBATT: LiFePO4 voltage, 2.7v to 3.4v typical.
Green LEDs: Kingbright APHCM2012CGCK-F01
Yellow LEDs: Kingbright APT2012SYCK
Red LEDs:
Kingbright APT2012SURCK
Page 21 of 23
Field Phone System Manual v1.0
19 September 2016
Slightly Higher Input Voltage
We have specified the input voltage rating at 30 volts, but this is a limitation of the 30v input zener diode (D1),
rather than the charger chip (U1). The charger chip can actually handle up to 34 volts, but D1 helps protect this
part against transients. D1 can also help pull down low-current high-voltage inputs (such as weak, high-voltage
solar panels) as long as its 1 W rating is not exceeded. Also, D10 is a Schottky diode, which gives an extra 0.4v
of input voltage (which is why we specify a 6v input rather than the 4.95v the charger chip handles). For small
voltages above 30.4 v, some upstream series silicon diodes will work nicely. The switching charger is set to
consume about 1.6 W, so at 30 v it is using very little current. As a result, even low-power fractional-wattage
diodes will do. Remember, however, that this will also raise the minimum voltage at the low end, and increase
the current through the additional diodes at low input voltages.
Also, pay attention to the DC IN indicator LED. At voltages near the high end of the 6v to 30v input range, this
LED begins to consume a larger and larger fraction of the available power. If your intended mode is to
consistently operate at the high end, increase R1 to decrease the current consumed by this indicator. This LED
has a typical forward voltage of 2.1v, and can handle up to 30 mA on a continuous basis, but operating it near 5
mA produces excellent results.
Much Higher Input Voltage
Amazon is littered with convenient little buck regulator modules that cost less than what we can buy the parts for
in bulk. Even the small versions of these can handle the input current requirements at the high end of the input
voltage range. Hot-melt glue one to the back of the FPHM, wire it up, and you are done.
Adjusting the Charge Current
The charge current is set to 500 mA by R9, a 0.2 ohm 1% 0603 surface mount resistor. This value can be
changed in accordance with the LT3652HV datasheet to allow as much as a 2A charge current or as low as
desired to reduce charger noise. While we wouldn't recommend 2A to charge the provided 1100 mA 18650
battery, a higher charge current might be acceptable for larger format LiFePO4 batteries wired into the same
contacts. If you do go for a higher current, blue-wire the trace between R9 and C4 to make it much thicker.
Adjusting the Float/et al Voltage
Don't, unless you want to use some other battery technology besides LiFePO4. Such as if you have cases of
lithium ion or lithium polymer batteries lying around. This is a non-trivial modification; examine the circuit
board and figure out what components are what by comparing to the datasheet (if you get stuck, ask us, but you
really shouldn't).
It would probably be cheaper in time, effort and cash just to buy some LiFePO4 batteries in bulk.
Custom Ring Indication
The FPHM buzzer gets energized with battery voltage, less at a RIM on the far end of a long wire. Even with
long wires, there should be enough residual voltage to run the base of an NPN to help boost the indication or
trigger a dependent relay. Be careful with custom ring indicators, a nearby lightning strike could trigger a ring,
and those buttons are easy to hit by accident. Make sure you really want that thing to ring if you take this route.
Page 22 of 23
Field Phone System Manual v1.0
19 September 2016
Using More Phones
To support additional phones beyond the five supported innately, the line current may have to be increased on
the LT3909. This is currently set to 30 mA on each line by R8, a 30k 1% 0603 resistor.
Using Longer Wires
Although we have tested the unit with simulated 1/4 mile wires (for technical feasibility, not for FCC
compliance), longer wires will require a higher line voltage. R11 (30k 1%) and R12 (330k 1%) currently set this
to a maximum of about 14.6v (normal operation will be around 8v). The chip is capable of creating line voltages
up to 36 volts, but the higher you set this, the more current the FPHM will draw.
With higher voltages, you may also lose your master phone. The reason for this is that this constant current
driver pumps 30 mA into each line (60 mA if the lines are bridged), while most phones pull the line down to a
few volts. Those few volts then have to go over long lines to the remote phones. If the master phone is located
close to the FPHM (reasonable assumption because that is where ring indication lives), then when it goes offhook, the voltage available to the far-away remote phones dwindles to nothing.
The solution to this is to run lengths of wire to all phones as equal as possible, or simulating length to a nearby
phone by using series resistors. This will make the voltage at the FPHM nearly equal when any phone goes offhook. You may have to experiment with this some for your particular installation, but we have found that 22 ohm
resistors work pretty well.
Another victim of long wires is ring indication. Although the AI-1441-TWT-12V-R buzzer uses only 7mA, this
causes a significant drop over long distances. A custom ring indication circuit with a local power supply and a
transistor to trigger things can solve this problem. If the field phone system sells well enough, we may introduce
such a thing. Or, if someone wants to provide an open-source option, we'll let our customers know about it.
Conformal Coating
A useful modification, once you are satisfied with the operation of the field phone board and don't want to make
any further modifications, is to add a conformal coating, which will provide additional protection against electrostatic discharge or shorting, including, to some extent, by water. This can be done a variety of ways, whether by
a plastic dip coating or spray, multiple sprays of urethane or other sealant, or epoxy. Be sure to tape off the phone
connectors, switches, jumpers, battery socket and power connectors first, and any LEDs you want to be able to
see, assuming you aren't using a clear coating.
Obviously, many portions of the board can't be coated, but you can reduce the possibility of shorting the board,
especially by accidentally laying it on metal obstructions. Accordingly, the first location to conformal coat is the
back of the board, which will greatly eliminate the chance of such shorts, and you won't need to mask off
anything back there.
Bulk Purchases or Special Combinations
Want to buy components in bulk for groups of enthusiasts, or want discounts on special combinations we haven't
listed on our webstore? Let us know and we'll try to help.
Page 23 of 23
Was this manual useful for you? yes no
Thank you for your participation!