SWEEP EQUIPMENT DATA SECURITY
SWEEP EQUIPMENT
DATA SECURITY
THE SYSTEM TO DETECT RF BUGS
AND SIGNAL ANALYZING
OMEGA
General:
The OMEGA is a powerful computerized system, designed
to monitor and analyze the electromagnetic environment.
It can be used for a continuous automatic monitoring in
premises to detect new signals (threats).
High resolution and sensitivity combined with high
scanning speed, allow to detect any suspicious source of
electromagnetic radiation in the frequency range from 10
kHz to 18 GHz. Scanning speed can be up to 100 MHz/sec
with 2 kHz resolution.
Original algorithm of spatial localization of suspicious
sources of radiation, based on remote antennas, enables
to detect signals from micro transmitters regardless of
their modulation and coding.
Digital vector analyzer, being an integral part of the
system, is very useful to identify eavesdropping devices. It
records transient, spectral and modulation characteristics
of signals, including impulse and single ones, which are
used in spread spectrum frequency hoppers and systems with time division channeling.
The OMEGA software allows to accomplish all the principal tasks of radio monitoring, such as: to
monitor the preset bands or single frequencies, to detect suspicious signals, to measure their
parameters, as well as to classify the detected signals according to various criteria and to store them.
Main changes in the software aim to upgrade the algorithm of fixing the location of the radiotransmitters, and for the user's convenience. This modernization improved its operating reliability and
stability on a 24 hours basis.
The OMEGA can be used to set up a stationary or mobile radio monitoring post.
It is assembled in a durable waterproof case, specially designed for transportation of electronic
devices.
The OMEGA hardware can be modified to accomplish specific radio monitoring tasks.
Main competitive advantages:
• Rapid scanning
• High sensitivity
• High resolution
• Perfect analysis and identification of signals
MICRO VIDEO CAMERA DETECTOR
STILETTO
General:
"Stiletto" is the portable optical detector, which is
designated to detect micro video cameras often
camouflaged in details of interior and clothes. "Stiletto"
detector is portable, easy to operate and will expose
even switched-off cameras with objective diameter less
than 1 mm.
Tiny, smart and invisible threat may bring a havoc
to your life
Relatively cheap, easy and wide spread such cameras,
often concealed in casual items and used by voyeurs and
spies, are a serious menace to private life, business and personal security.
2
Skilled answer to serious challenge
Specially designed powerful and clean optics, IR illuminator and focusing option supported by battery
level indicator provide you professionally built solution to deal with unseen threat. It doesn't matter in daylight or in darkness - if the camera is pointed at you, the device detects the camera. "Stiletto" is
necessary to feel confident and calm at home, in the office, during negotiations and in hotel's room.
VIDEO-SURVEILLANCE DETECTOR
AMULET
General:
The device is designed for detecting and sweeping video-surveillance
units anywhere independently of their video - signal processing and
transmitting modes.
It is possible to detect hidden video cameras and evaluate the distance
to the detected units.
The device may be used either in the sweep or in the alarm modes.
The operation principle is based on both environmental
electromagnetic analysis and recognition of the RF emission from the
video-surveillance units.
The device may be easily controlled and its operation doesn’t require
specific knowledge and skills.
In order to evaluate the distance to the hidden video- surveillance
units the device is equipped with an external probe.
Detection distance:
Detection time:
Power supply:
Operation time from battery:
Specifications:
6 - 10 m.
from 50 sec to 6 min.
AC 220 V, DC 12 V, built-in rechargeable battery.
not less than 2 hours.
MULTIFUNCTIONAL DETECTION INSTRUMENT
ST 032
General:
The ST 032 Multifunctional Detection Instrument is
used to detect and locate various appliances used
for furtive acquisition of information (hereinafter
called ‘Special Technical Means’, or ‘STM’), to
reveal natural and artificial channels of information
leakage, and to monitor the level of information
security.
The instrument consists of the Main Control and
Indication Unit, and a set of Transducers, and is
capable of operating in the following modes:
•
•
•
•
HF detector/frequency meter, with the
identification of GSM and DECT signals;
identification of GSM and DECT signals;
differential mode;
control of the scanning receiver.
3
•
•
•
•
•
•
•
conducting line analyser;
infrared detector;
low frequency magnetic field detector;
differential low frequency amplifier;
acoustic vibration transducer (optional);
acoustic transducer (optional);
control of the conducting line scanning receiver (AOR8000, 8200, 5000).
The information is displayed on a liquid crystal screen. Sound output is available via headphones or
speaker. ST 032 can be powered from 1 type AA battery, or a power unit. ST 032 is a portable unit.
For handling and storage a special bag is used, tailored to house all the components in a convenient
way.
Specifications:
Radio frequency detector-frequency meter
Operating frequency range
Sensitivity at input
Dynamic range
Frequency meter sensitivity
Frequency measurements accuracy
Conductive wire lines scanning analyzer
Scanning range
Sensitivity for signal/noise ratio 10 dB
Band width
Detection modes
Allowable mains voltage
Infrared radiation detector
Spectral range
Band width of detection
Threshold sensitivity
Low frequency magnetic fields detector
Frequency range
Threshold sensitivity
Vibro-acoustic converter
Frequency range
Sensitivity
Acoustic converter
Frequency range
Sensitivity
Low frequency differential amplifier
Normalized noise voltage at the input
Dynamic range
Input impedance
Common-mode interference damping factor
Frequency range
Maximum allowable input voltage
Power
Power supply (DC)
Maximum consumed current
Consumed current in operating mode
Dimensions and weight
The principal control, processing and indication unit: overall
dimensions
The principal control, processing and indication unit weiqht
Complete set: weight
30-2500 MHz
<1 (30MHz-1000MHz) mV;
<4 (1000MHz-1800MHz) mV
63 dB
<15 mV
± 0.01 MHz
0.05-9 MHz
<1 mV
10 kHz
AM, FM
600 V
770-1000 mm
0.3-300 MHz
10-13 W/Hz1/2
0.5-300 kHz
10-11 T/Hz1/2
0.3-6 kHz
1 V*s2/m
0.3-8 kHz
>5 mV/Pa
<2 uV
60 dB
200 kOhm
>60 dB
0.2-15 kHz
70 V
1.5 (1 battery, AA type)/220
V
<200 mA
<100 mA
157х62х28 mm
0.25 kg
1 kg
4
PORTABLE BUG DETECTOR
PROTECT-1203
General:
Is designed to efficiently search and locate all types of RF
bugs, including digital transmitters, as well as transmitters
with spectrum inversion.
Operation principle is based on monitoring premises to
detect new connections. When in this mode, PROTECT
1203 is tuned to the sensitivity level applied to this
environment. Then you just move to the center of the
square or area, which, as it seems to you, is subject to
risk. By repeat tuning the sensitivity level, you can tune to
a transmitting device at the distance of 2 m. from its
location. By decreasing antenna, you can disable facilities
illegally connected. PROTECT ’s 1203 vibrator will let only
you know about the presence of eavesdropping facility. If
this function is activated, PROTECT 1203 starts vibrating
without noise, that means that there is an eavesdropping
facility. If there are no bugs at the current moment,
PROTECT 1203 monitors possible connection in further.
Display will show you the fact of presence of RF facility on
your “territory free from bugs”.
PROTECT 1203 is capable to detect the following types of
bugs:
•
•
•
•
Indoor and car transmitters.
Phone transmitters.
digital transmitters and transmitters with spectrum inversion.
Tracing facilities.
Transmitters to be carried on body.
Specifications:
Frequency range:
Charging time:
Dimensions (in case):
Weight:
Power internal battery:
10 MHz ... 3600 MHz.
12 hours.
26 x 75 x 160mm.
420 g.
3.60 V.
PORTABLE SEARCH INSTRUMENT
D-008
General:
The D 008, broadband detector of electromagnetic fields
is intended for detection and localization of special radioemitting technical means (STM) used for secret
acquisition of information.
These means primarily include the following:
• radio microphones;
• telephone retransmitters;
• radio stethoscopes;
• concealed video cameras equipped with a radio
channel for transmission of information;
• radio-range beacons of the systems used for moving
objects monitoring (e.g. people, transportation means,
goods etc.);
• unauthorized operating cordless phones and radio
stations;
5
D 008 employs two channels of detection:
• field detector, meant for the detection of radio-transmitting data acquisition means (RTDAM);
• conductive line analyser, meant for the detection of 'bugs' using conductive lines for data
transmission (110/220V AC power lines, phone lines, alarm lines etc.)
While in the field detector mode, at the core of its function is the broadband electric field detection,
which allows to discover RTDAM regardless of their modulation type. Effective range of detection
depends on the radiated power, frequency of the emitter (STM), electromagnetic background in the
inspected area; and is about 1m at the emitted power of 5 mW.
The attenuator facilitates operation in a problem electromagnetic situation typical for a large industrial
centre. It is also helpful in locating powerful radio-transmitting data acquisition means (RTDAM).
The active HF antenna is used for the tracking of RTDAM operating in the UHF range. The conductive
line analyser consists of an external line adapter used to connect to lines with voltage above 500V,
and a superheterodyne receiver with an AM/FM demodulator.
Sound output is available via headphones or speaker.
For a prompt and reliable connection of the line adapter to various types of conductive lines, a set of
extensions is supplied.
The acoustic feedback mode allows to eliminate the danger of false alarms by D 008, as well as
identify RTDAM by their typical acoustic signal. A 10-segment light-emitting diode scale, together with
an optional tonal sound signal, make the device comprehensible and convenient to operate.
Specifications:
Frequency range
Sensitivity on the input (F=100MHz; F=800MHz; F=1400MHz)
Attenuation
Active Antenna frequency range
Active Antenna amplification
Dynamic Range of Indicator
Conductive Line Analyser
Frequency range
Sensitivity at the relative noise 20dB, AM depth 30%
Pass band
Modulation type
Maximum input voltage of line adapter
Power Voltage
Current (Standby Mode; Operation Mode)
Dimensions of Primary Unit
Dimensions of Bag
Primary Unit weight, Gross weight
50...1500 MHz
<2; <1.5; <6 mV
20 dB
400...1500 dB
7 dB
20 dB
0.05...7 MHz
< 4 mV
200 kHz
AM, FM
500 V
9V
<30; <100 mA
148х68х24 mm
180х100х75 mm
0.18; 0.55 kg
REMOTE SWITCHING ON VIBROGENERATOR DEVICE
BARON-V
General:
For remote VIBROGENERATORS of BARON type. Provides
switching on (switching off) VIBROGENERATORS with the
help of own controls, and also as the interface equipment
for submission of commands to switch on (swithch off)
VIBROGENERATORS from the PC manager. The device
provides remote control by twelve VIBROGENERATORS.
It is structurally executed as the module for installation in RACK frames (cases).
6
DEVICE FOR EFFICIENCY OF VIBRATING HANDICAPES CONTROL
BARON-K
General:
For the control of efficiency of the vibrating handicapes
created vibroacoustic by generators of type BARON or the
similar equipment. Provides the prevention of reduction of
the vibrating handicap level on protecting design of the
protected room below the allowable one as a result of failure
of vibrators, the generator of handicapes, change of
environmental conditions. The principle of work of the device
consists in the following. To the device it is connected
vibration pickup, providing set a signal from a controllable
surface. The signal with vibration pickup is filtered, amplifies
and compared to the established threshold. If it of below
given threshold the device submits an alarm signal. For the
exact control making picture vibration pickup a signal the
stipulated special output(exit) on an oscillograph or fourier
analyzer. The socket for connection to the general(common)
board providing the remote control of functioning of
vibronoising system about use of group of BARON - K
devices is stipulated. BARON Vibroacustic protection can connect to one complex up to 10 BARON - K
devices.
PHONE SPEECH SECURE MODULE
ACCENT
General:
The module is designed to protect the municipal telephone
station by method of putting an active noise suppressing
on any telephone bug’s action during the talk. Several
know-hows which are implemented in the design of the
device allow to prevent pick-up and transfer of data over
telephone-line in the intervals between telephone talks.
The device allows to detect the attached telephone bugs
and to control steady component of voltage in the
telephone line. The protection module is simple in
operation, practically doesn’t require operator’s
adjustment; the production activation during talks is performed by pressing of a single push-button on
the panel or on the distance control. If necessary one may adjust noise level and line voltage control
is attained by the built-in voltmeter. The module supports light indication of operation modes and
telephone line condition as well as light indication of unauthorized line usage in the interims between
talks. Attachment of recording device ensures documenting of telephone talks.
Features
•
•
•
•
•
The telephone line during a talk is protected along its entire extension from the module to the
telephone station.
Suppression of telephone bug’s normal operation under any kind of their attachment during
the talks is attained by reloading of incoming circuits with two active noises of different
physical parameters.
Advanced detecting system of non-linear devices attached to the telephone line.
Built-in detector determines and indicates an active telephone attached to in-parallel even
with turned of protection.
The built-in automatic device allows for temporary protection deactivation to prevent failures
during dialing.
The protection module may be easily incorporated into the configuration of the office telephone station
network. On that purpose the module is equipped with a system of a remote control over the
telephone line which allows for using of the protection modules number equaling the incoming town
lines’ number and monitoring the protection via any of the telephone sets attached to the inner
telephone station.
7
Specifications:
Line type requirements:
Power supply:
Dimension:
Usage conditions:
analog 10/60 V.
AC 220 V.
200 x 150 x 55 mm.
interior.
SECURE SPEECH COMMUNICATION DEVICE
REFERENT
General:
The device is designed to secure unclassified voice
communications.
REFERENT allows to operate in both standard and
secure modes and provides reliable secure in
standard phone channel.
The voice quality of secure calls doesn’t differ from
voice quality of standard calls.
REFERENT is designed to secure voice information over Public Switching Telephone Network (PSTN)
and leased lines (like government switched telephone networks swell).
An expensive, dedicated transmission path is not needed to ensure security.
Features
Encryption
•
•
strong encryption stream algorithms (symmetric crypto as optional);
private 32 bit key (256 bit as optional).
Speech coder
•
4800 bps full-duplex CELP.
Modem
•
•
•
full duplex;
4800 bps bit rate;
fast synchronization - 12 sec;
enhanced channel compensation adapted for noisy telephone channels.
RF-JAMMER
VETO-SERIES
General:
The devices are designed for jamming any types of RF
signals in wide frequency range. The operation principle of
the device is based on the emission the white RF noise into
environment to suppress the RF transmitters around. The
devices ensure sensitivity data against leakage not only by
outer electromagnetic emission from PC as well as by
radiation created by various RF mikes with radiating output
up to 1 mW.
VETO eliminates ability of duplex communication by means
of both transceivers and cellular phones.
8
Specifications:
Frequency range
Output power
Power supply
Options
Opt. V-01 Battery power supply.
1000...2000 MHz
10 W
AC 220 V
VIBRO - ACOUSTIC GENERATOR
FORUM
General:
The generator is designed for interiors protection against
audio-data pickup facilities engaging a microphone.
The device generates both acoustic and vibration noise-like
signal being reproduced via dynamics and vibro transducers. Smooth adjustment of the noise acoustic
signal is provided. The device is distinguished by use of
vibro-transducers based on piezoceramics which allows for
high output when generating the vibration noises’ required
level.
Specifications:
Maximal number of vibro - transducers:
Required load impedance of the audio-signal output:
Power requirements:
Peak value of power consumed:
Dimensions:
Weight:
6.
not less than 16 Ohm.
220 V.
10 W.
220 x 112 x 45 mm.
1.3 kg.
PORTABLE RF JAMMER
BREEZE
General:
The device is designed to protect informatization objects
of category 2. According to the principle of operation, the
device is a wide-band generator, which makes a masking
signal within the range up to 1,0 GHz, with the power no
less than 5 W, that enables to:
•
•
•
mask
secondary
compromising
emanations,
transmit and store data (first of all, from PC);
block RF channels, used by remote data pick-up
devices with the power up to 5 mW;
block receivers of various remote control systems
(RCS) over RF channel (RCS data pick-up devices,
etc.).
It's made in a plastic housing with the telescopic aerial.
Other versions of the device design are possible as well as
completing with other types of outer aerials.
9
Specifications:
Frequency range:
Integral indicator of output power:
Power supply:
Power consumed:
Operation hours from the fully charged battery:
Dimensions:
Weight:
0,1 - 1000 MHz.
no less 5 W.
from mains 220V; from
battery 12V.
no more 15 WVA.
no less 1 h.
50x95x145 mm.
no more 1 kg.
PORTABLE TAPE- & DIGITAL RECORDERS SUPPRESSOR
STORM
General:
The suppressor is designed to prevent unauthorized
confidential talks recording by tape - & digital recorders.
The product is represented by with a brief - case containing
a suppressor assembly with a built - in directed aerial. As a
result of the product’s radiation effect on a disguised taperecorder a noise signal is recorded instead of a talk.
The device may operate both in mobile and stationary
mode, it is disguised inside a conventional brief - case
which allows for its latent use.
The instrument is equipped with a remote control. Upon
the customer’s request a stationary suppressor’s option is
provided which may be disguised as a home tape recorder, TV set and other facilities.
List of the kit components
Brief - case including suppression assembly, built - in aerial and rechargeable batteries set, charging
device, instruction manual.
Specifications:
Suppression area for portable tape - recorders in a metal a sector having an angle of not less than 60
casing):
and a radius of up to 8 m.
Duration of continuous operation from built - in
up to 1,5 h.
rechargeable batteries:
Power requirements:
either 220 V A.C., 50 Hz or 12 V D.C. from
batteries.
Power consumed:
not more than 60 W in the suppression
mode.
Dimensions:
550 x 450 x 110 mm.
Weight:
not more than 7 kg.
EXPRESS DATA ERASERS
STRIKER-SERIES
General:
The device is designed for effective erasure of information from
FDDs, ZIP-Disks, audio- and videocassettes as well as HDDs both
in operational and non-operational modes. The full data erasing
time is around half second. After the information is erased by
STRIKER, it cannot be restored even experienced specialists who
use up-to-date equipment to do it.
10
STRIKER is available in two models:
•
external for FDDs, ZIP-Disks, audio- and videocassettes and HDDs in nonoperational mode;
internal for HDDs in operational mode. The external model provides high-speed and reliable erasure of
a big quantity of data storing units before their destruction. The internal model is placed into PC and
allows rapid erase data on the HDD in real time mode.
Specifications:
Data erasure time:
Power supply:
0.5 sec.
AC 220 V.
Options
Opt. S-01 Wireless remote control
Opt. S-02 Battery power supply
NON-LINEAR JUNCTION DETECTOR
MASTER PLUS
General:
For detection of the included and switched off latent
overhearing devices, sound recording devices, and also
explosives with the electronic detonators controlled on the
radiochannel; exact definition of a site of the found out
radiodevices; distinctions of electronic object from noise
contact object; definitions of a mode of operation of the
device (switched on – swithced off). Ensures the
functioning in conditions of influence of the strong external
radio noise created: cellular communication, television
transmitters, radio stations, radio telephones etc. Detection
is carried out by an irradiation of a controllable zone by a
continuous or modulated probing signal with the
subsequent reception and the analysis of a signal of the
response simultaneously on the second and third
harmonics of irradiating signal. The information on the fact
of detection is given out as a sound signal in headphones,
and also on a control panel as light signals on indicators of
a level of red color at detection of electronic object or on
indicators of a level of green color at detection contact
noise object.
Specifications:
The type of radiation
Capacity of the MICROWAVE – SIGNAL on a target socket of the
send-receive block
Sensitivity of accepted signals frequencies of 2-nd and 3-rd
harmonics
Frequency radiating the MICROWAVE of a signal
Factor of amplification(strengthening) of the aerial with linear
polarization
Factor of amplification of the aerial with circular polarization on
linear a component
Depth of adjustment of sensitivity
Depth of adjustment of capacity
Weight carried the operator at work of the complete set of the
equipment
pulse or continuous
2-4 W (adjustable)
is not worse a minus 145
dB/W (adjustable)
980. 1020 MHZ
(reconfigurable)
on 1-st harmonic +3 dB on
2-nd and 3 harmonics +7 dB
on 1-st harmonic +3 dB on
2-nd and 3 harmonics +6 dB
45 dB (aside reduction)
20 dB (aside reduction)
no more than 3,5 kg
11
HIGH-SPEED EAVESDROPPING RECEIVER
SCORPION
General:
It is designed for quick detection of unauthorized radiotransmitters and distortion
them by high accurate spot jamming.
It provides:
• It realizes an examination of the radio-electronic conditions of the apartment with
frequencies recording;
• It detects and fixes positions unauthorized radiotransmitters in the controlled
apartment;
• It distorts of unauthorized radiotransmitters by high accurate spot jamming.
The main distinction is an easiness in operation. Four buttons are designed to
choose the mode of the receiver. It works as a scanning receiver under the
operation of the pocket PC. The automatic gain control circuit of low frequencies
allows to receive NFM/WFM signals with the equal loudness. Oscillator’s tuning in the
«search» mode is effected automatically with 200kHz steps. The device is switched
automatic-frequency mode with the step 10kHz when it detects a signal with a level
bigger than the detecting threshold. It also has a liquid crystal display and an
internal speaker to control demodulate signals (NFM and WFM).
Specifications:
Frequency range
Power capacity of the spot jamming in the range of 301000MHz
Time of frequency range scanning
Sensitivity
30...2000 MHz
not less than 50mW
15 sec max;10 sec. without signals
50microV in the frequency range 30 –
1000MHz;1mV max in the frequency
range 30 – 1000MHz
Intermediate frequency band pass
200kHz
Measuring frequency accuracy
10kHz
Measuring range of the input signal level
50dB
Number of excluded channels
4850
Number of recording detected channels
256
Indicator’s information
LCD dispays: Signal frequency; Input
signal level; Detection threshold level;
Dynamic menu of the main functions;
Number of excluded and detected
channels; Battery conditions
Spot jamming capacity in the frequency range 30....1000 50 mW min
MHz
Power supply sources
batteries/accumulators with total
voltage 9,6 – 12V
External direct current source
9,6 – 12V
Consumption current in the receiving/transmitting mode 200mA
Number of memory channels
256
Dimensions
165x95x29 mm
THE IMITATOR OF RADIOLAYING DEVICE (RF BUGS) SIGNALS
AURORA-T
General:
Provides forming and generation radio signals which are imitate the working of
all types of RF bugs.
12
Specifications:
Range of working frequencies
Brought set capacity to the aerial
Depth AM
Index FM
Index PM
Modulation signal
Pseudorandom retuning RF:
Range of hopping reorganization of frequency
Quantity of channels reorganizations
Quantity of reorganizations in seconds
Width of a channels strip
Noise-shaped signal
Strip of a formed signal
Base of a signal
Over-short transmission:
Strip of a formed signal
Time of a signal transferring
Time of a signal accumulation
Speed of the information transfer
Power supply
50 MHz-2 GHz
from 1 mW till 1000 mW
up to 80%
1…100
1
one, two-frequency or
speech signal from a
microphonic input in a strip
of frequencies (300Hz –
3500Hz); outside TV signal
up to 120 MHz
up to 8000
up to 2500
2-50 kHz
100kHz-50MHz
10-5000
300kHz-25MHz
from 10ms up to 120 sec
from 1 sec up to 60 min
from 10 kbit up to 10Mbit
from the accumulator and
from a network of an
alternating current 200V
THE DEVICE FOR PROTECTION OF CONVERSATIONS BY A GENERAL MOBILE PHONE
FROM IT INTERCEPTION LISTENING
REFERENT GSM
General:
It is used for prevention of an opportunity of listening of
conversations by a mobile phone both ft a level of
operators of cellular communication, and by means of
complexes of GSM interception. The device can work in
cellular networks of the GSM standard, in which function
of data transmission (Mobile office) is supported and
works with the mobile phone as the external device.
Initial speech is exposed to the analog - digital
transformation representing high – speed 64 kbit a
digital stream is compressed till the speed 2,4 kbit/s,
and then processed by special algorithm and in such
condition it is transferred by the modem of a mobile
phone under the GSM data link.
The device “Referent GSM” is intended for work with
mobile phones such as Ericsson and SonyEricsson and
supplied by a corresponding target socket for a joint with a modem input of phone.
"Referent-GSM" is combined with the following models of phones:
• Ericsson T28, T39, T61g, T68, R520;
• Sony-Ericsson T68i, T200, T226, T238, T300, T310, T316, T610, T616, T618, Z600, Z1010.
Such models as T66, T600, A3618, T100 can’t work with Referent-GSM because of the absence
internal communications of the socket with the modem of phone.
Other models of this class, which have corresponding socket and connection with the modem of phone
were not tested.
13
Specifications:
Vocoder
Consumed current (mode of expectation/operating mode)
Weight
Dimensions
MELP 2,4 Kbit/s
10 mA/30mA
22 grams
54X41X15 mm
MOBILE PHONES JAMMER
KVARTET-4
General:
The device is designed for blocking operation of mobile
communication systems phones over the range of the
rooms intended for negotiating, carrying out of meetings.
It is used for prevention of information leakage outside the
place using overhearing devices over channels of mobile
communication systems, using turned on phones of listed
classes for information transfer, and also for providing
working atmosphere during negotiating, in a meeting.
Features:
• 4 channels (generating modules) for noise signal
generating
• possibility for client to choose a set of necessary
generating modules (channels), up to 4 in one case, that
lets to adapt the system for different operation conditions
in dependence on cellular standards in different regions,
and also to adjust suppression distance – from 20 to 40 m
(2W for every channel) and from 40 to 60W (4W for every
channel)
• possibility to install or exchange generating modules for
different frequencies after product purchase in case of
cellular standards changing in operation region
• the spectral characteristic of generated noise provides
the big cover zone at identical power of radiation in
comparison with similar products, that allows to reduce irradiation power of the user to smaller value;
• adjustment of output power does not influence on the spectral characteristic of a signal;
• detector and indicator of radiation on each channel;
• Flat beam aerial for GSM 900, 1800 range allows to concentrate radiation energy in the necessary
zone that increases operation distance at the same power; allows to reduce power of user irradiation
to smaller value (optionally).
• Power of radiation 4 W by the channel, adjustable. Range of suppression of a single-channel device
up to 50 m. Any combinations up to 4 channels (generating modules for different ranges) on a choice.
Specifications:
Frequency ranges (channels)
Radiation power
Single-channel device suppression zone radius
Power supply
Dimensions
GSМ-900/1800, optionally СDМА-450, GSM 1900
4 W smooth adjustment (by
the channel)
up to 50 m
180-240 V, 50/60Hz
300x190x100 mm
14
DETECTOR OF ELECTROMAGNETIC FIELDS
ST 007
General:
The ST 007 EMF (electromagnetic field) Detector is designed to
detect and locate the sources of electromagnetic radiation from
devices intended for the unauthorized obtaining of information
(eavesdropping devices), such as:
• radio microphones;
• telephone radio transmitters;
• radio-stethoscopes;
• hidden video cameras equipped with a radio channel for
transmitting information;
• systems of spacial high-frequency radiation in the radiofrequency range;
• systems for transmitting image from computer monitors using
a radio channel;
• radio beacons for tracking moving objects (people, vehicles,
freights, etc.);
• unauthorized radio stations, wireless phones, and phones with
wireless extensions;
• unauthorized use of GSM and DECT cellular phones;
• unauthorized use of Bluetooth and 802.11 (WLAN, WiFi) devices with a frequency range of 2.4 GHz.
The ST 007 utilizes the principles of wideband detection of electric fields. The ST 007 operates in three
main modes:
• Search;
• Monitoring;
• Log view.
Search Mode
This mode is intended for detecting sources of electromagnetic radiation.
When in Search mode, the ST 007 receives radio signals in the range of 50 to 2,500 MHz, detects
them, and outputs them to the built-in display and as an audio signal to the earphones and the builtin speaker. The level of the signal in comparison to the threshold level is indicated on two 32-segment
level meters on the display.
The difference between the two meters is as follows: the top meter indicates the average amplitude of
the detected signal; the bottom meter shows the signal’s peak values. AM and FM signals will prevail
in the top meter; signals resembling pulse types (such as DECT or GSM) will be displayed on the
bottom meter. When the ST 007 detects mixed signals on its input (TV signal, for example), it will
display them on both bars.
The ST 007 can measure current frequency values of the radio signal and determine its most stable
value (for signals with a constant carrier frequency).
The ST 007 also displays the detection of GSM, DECT, Bluetooth, and 802.11 (WLAN, WiFi) signals.
In order to attenuate the interference of powerful radio transmitters of up to 300 MHz (TV
transmitters from Channel 1 to Channel 10, FM radio stations), a low-pass filter is used.
If you connect a scanning receiver with a special communications port to the ST 007, its reception
frequency can be set to match that of the reception signal of the ST 007.
Monitoring Mode
The Monitoring mode is intended for detecting sources of electromagnetic radiation and storing data in
NVRAM. The maximum number of events that can be stored in NVRAM is 4,096. The events can be
viewed when the detector is in the Log View mode. The Monitoring mode has an extended range of
alarm signals, which can be triggered if the signal passes a certain level or frequency threshold, or if a
certain type of signal is detected (GSM, DECT, Bluetooth, 802.11).
It is possible for the user to schedule the ST 007 to turn on and off.
15
This mode has two basic operations:
User controlled operation
The ST 007 is placed so that it is visible to the user. This is useful for detecting devices for the
unauthorized obtaining of information among the visitors of an office, for example.
Autonomous operation
The ST 007 is placed in an area where the use of eavesdropping devices is suspected, and the
electromagnetic environment will be monitored during a pre-programmed period without user
interference.
Protocol View mode
The Protocol View mode is intended for viewing the log of events stored in the ST 007’s NVRAM during
Monitoring.
Events can be sorted by:
• time;
• duration;
• signal level;
• frequency value.
The results of are indicated a four-line LCD with a resolution of 97 x 36 pixels as digits and text, as
well as additional pictograms at the top of the display. The ST 007 is controlled from a six-button thin
film keypad Sound output is available via headphones or speaker. On the screen, help can be
displayed, available in both Russian and English.
ST 007 can be powered from either 4 type AA batteries, or a power supply (included).
For software upgrades (new versions, additional features), connect ST 007 via Serial Port to your PC,
and visit the manufacturer’s site; the instrument will be reprogrammed automatically.
Specifications:
Frequency range
Low-pass filter cutoff frequency
Input sensitivity:
100-1200MHz
1200-2000MHz
Frequency meter sensitivity
Frequency measurement error
Display dynamic range
Power supply
Average current consumption
Dimensions (without antenna)
Weight (without battery)
50-2500 MHz
400 MHz
<0.25 mV
<0.5 mV
<15 mV
±0.1 %
60 dB
internal AAA battery 1.5 V;
external power supply 4 V
<60 mA
85x53x19 mm
0.1 kg
DETECTOR OF ELECTROMAGNETIC FIELDS
ST 006
General:
The ST 006 EMF (electromagnetic field) Detector is designed to detect and locate
the sources of electromagnetic radiation from devices intended for the
unauthorized obtaining of information (eavesdropping devices), such as:
• radio microphones;
• telephone retransmitters;
• radio stethoscopes;
•
hidden video cameras equipped with a radio channel for transmitting
information;
• systems of spacial high-frequency radiation in the radio-frequency range;
• systems for transmitting image from computer monitors using a radio channel;
• radio beacons for tracking moving objects (people, vehicles, freights, etc.);
• unauthorized operating cordless phones and radio stations;
16
• unauthorized use of GSM and DECT cellular phones.
The ST 006 utilizes the principles of wideband detection of electric fields. The ST 006 receives radio
signals in the range of 50 to 2,500 MHz, detects them and outputs them to the 16 segment LED level
meters and as an audio signal to the built-in speaker. The ST 006 also displays the detection of GSM
and DECT signals. Mode of acoustic feedback is available. LED level meter is displays the level two
type of signals: the average amplitude of the detected signal and signal’s peak values. In addition the
LED level meter is used to control of battery and set level of audio feedback.
Specifications:
Frequency range
Input sensitivity:
F=30-800 MHz
F=800-1700 MHz
F=1700-2400 MHz
Display dynamic range
Power supply (DC)
Average current consumption
Dimensions (without antenna)
Weight
30-2500 MHz
-56 dBm (0.35 mV)
-50 dBm (0.71 mV)
-42 dBm (1.8 mV)
48 dB
Li-Ion Battery 3.6V
40 mA
85x53x19.5 mm
0.15 kg
MULTIPURPOSE SWEEP DEVICE
PIRANHA
General:
The "PIRANHA" multifunctional countersurveillance
instrument is intended for implementation of
arrangements for detection and localization of special
technical means (STM) used for secret acquisition of
information, for revealing of natural and artificially
created channels for leakage of information as well as
for monitoring of information protection quality.
With the help of the PIRANHA instrument, one can find
solution to the following monitoring-and-search tasks:
• 1. Detection and localization of radio-emitting STM.
These means primarily include the following:
•
•
•
•
•
•
•
•
•
radio microphones;
telephone retransmitters;
radio stethoscopes;
concealed video cameras equipped with a radio
channel for transmission of information;
technical means of the systems for spatial
radio frequency irradiation within a radio band;
technical means for transmission of a picture
from PC monitor via a radio channel;
radio-range beacons of the systems used for
moving objects monitoring (e.g. people,
transportation means, goods etc.);
unauthorized operating radio stations, radiophones, and telephones with radio-extension;
technical means for data processing, whose operation is accompanied by generation of side
electromagnetic radiation (components in a PC, fax machines, photocopying machines, some
types of telephones etc.).
• 2. Detection and localization of STM means operating with emission of radiation within infrared
band.
These means primarily include the following:
17
•
•
STM means capable of transmitting in an infrared frequency band;
technical means of the systems of spatial irradiation within infrared band.
• 3. Detection and localization of STM means which use conducive lines of various intended
application, for transmission of information.
These means may include:
•
•
STM means which use alternating current electric lines of the power supply network, for
transmitting of the intercepted information.
STM means which use subscriber’s telephone lines, the lines of fire alarm systems and security
alarm systems, for transmitting of the intercepted information.
• 4. Detection and localization of the sources of electromagnetic fields with predominance (presence)
of magnetic component of the field, as well as analysis of technical means capable of converting
speech information.
The number of such sources and technical means typically include the following:
•
•
•
dynamic irradiators of acoustic systems (dynamic speakers);
output transformers in audio amplifiers;
electric motors in tape recorders and dictaphones.
• 5. Reveling of the most vulnerable locations, from the point of view of possible generation of vibroacoustic channels for information leakage, and assessment of efficiency of vibro-acoustic protection
systems employed in various premises.
• 6. Reveling of the most vulnerable locations, from the point of view of possible generation of
channels for acoustic information leakage, and assessment of efficiency of sound insulation employed
in various premises.
The instrument consists of the Main Control and Indication Unit, and a set of Transducers, and is
capable of operating in the following modes:
• HF detector/frequency meter, with the identification of GSM and DECT signals;
• conducting line analyser;
• infrared detector;
• low frequency magnetic field detector;
• vibration transducer;
• acoustic transducer.
• low frequency differential amplifier.
The information is displayed on a liquid crystal screen with adjustable backlighting.
The instrument is controlled with the aid of a 16-key film keyboard. Sound output is available via
headphones or speaker. The instrument allows to process the received low frequency signals in either
oscilloscopic mode, or spectrum analyser mode with a digital representation of data. Its non-volatile
memory can store up to 99 screen images.
On the screen, help can be displayed, available in both Russian and english.
PIRANHA can be powered from either 4 type AA batteries, or a power unit.
PIRANHA is a portable unit. For handling and storage a special bag is used, tailored to house all the
components in a convenient way. PIRANHA is protected by utility patent under the laws of Russian
Federation.
Specifications:
Radio frequency detector-frequency meter
Operating frequency range
Sensitivity at input
Dynamic range
Frequency meter sensitivity
Frequency measurements accuracy
30-2500 MHz
<1 (30MHz-1000MHz) mV;
<4 (1000MHz-1800MHz)
mV; <8 (1800MHz2000MHz) mV
60 dB
<15 mV
± 0.01 MHz
18
Conductive wire lines scanning analyzer
Scanning range
Sensitivity for signal/noise ratio 10 dB
Scanning increment
Scanning speed
Band width
Selectivity as per neighboring channel
Detection modes
Allowable mains voltage
Infrared radiation detector
Spectral range
Threshold sensitivity
Angle of sight
Band width of detection
Low frequency magnetic fields detector
Frequency range
Threshold sensitivity
Low frequency differential amplifier
Gain
Input voltage noise
Dynamic range
Input impedance
CMRR
Operating frequency range
Maximum input voltage
Vibro-acoustic converter
Frequency range
Sensitivity
Intrinsic noise within the band of 0.3-3 kHz
Frequency range
Sensitivity
Oscilloscope and spectrum analyzer
Band width
Sensitivity at the input
Metering error
Oscillogram output speed
Spectrogram output speed
Power
Power supply (DC),
Maximum consumed current
Consumed current in operating mode
Dimensions and weight
The principal control, processing and indication unit
The principal control, processing and indication unit
0.01-15 MHz
<0.5 mV
5(1) kHz
50-1500 kHz/s
10 kHz
30 dB
AM, FM
600 V
770-1000 nm
10-13 W/Hz1/2
30 grad
3 MHz
0.3-10 kHz
10-5 A/(m*Hz2)
22±1 dB
<2 mcV
>70 dB
>200 kOhm
75 dB
200-8000 Hz
<70 V
0.3-6 kHz
1 V*s2/m
50 uV
0.3-8 kHz
>5 mV/Pa
22 kHz
<10 mV
1 % of the upper limit
0.2 s
0.3 s
6(4 batteries, AA type)/220
V
300 mA
150 mA
180х97х47 mm; 0.8 kg
350х310х160 mm, not
exceeding 5 kg
SECURE VIBRO-ACOUSTIC SYSTEM
BARON
General:
This system is designed for interiors protection against audio-data pickup facilities (stethoscopes, laser
and directed microphones) in vibroacoustic channels (floor, ceiling, walls, windows, pipes, vent).
BARON has 4 jamming channels. To each of these channels can be connected: vibro-transducers (of
piezoelectric or electromagnetic type) and acoustic systems, which convert electric signal, formed by
19
Baron, into mechanical oscillations through protected building.
Advantages:
• Alldigital handle.
• The intelligent menu, floppy system of configuration.
• Possibility of interfering signal creation from different
internal and external sources and their combinations.
Internal sources - noise generator, phoneme’s clone,
intended for synthesis of speech similar interferences, by the
method of cloning main phoneme’s components of the
speech. This method is optimized for particular person
protection. The mixing of speech phoneme’s components on each channel decreases the probability of
noise clearing of a signal. Besides, the presence of a linear input allows to connect a special interfering
signal of heightened efficiency.
• Each channel has own independent noise generator (analogue type) and phoneme’s clone, that
allows to eliminate possibility of compensation of an interfering signal by resources of voice
information interception at the expense of special processing, including by correlation methods at
multichannel pick-up by several sensors.
• By one SECURE VIBRO-ACOUSTIC SYSTEM it’s possible to protect locations of large square of
different assignment (conference halls etc.).
• It’s possible to regulate a spectrum of an interfering signal for rise the efficiency of the directed
interfering signal in view of features used by both vibro- and audio transducers and defended surfaces
(5-band digital equalizer).
• Presence of four independent output channels with separate regulations for an optimal adjustment
of an interfering signal for different defended surfaces and channels of leakage.
• Built-in monitoring aids of established interferences efficiency: the check speaker for an expert
rating of established interference quality and low frequency four-channel 5-band spectrum analyzer
which operates with output signals from all 4 channels, possessing a wide volume range, that allows
effectively continuously to control the interferences of any level established in each of channels in
whole frequency operation range.
• Presence of remote control.
Options:
• Opt.01. pane vibro-transducer
• Opt.02. wall vibro-transduser
• Opt.03. window fame vibro-transduser
Specifications:
Number of interfering channels
Output power
4
not less than 18 W per
channel
60... 16000 Hz
Frequency range
Maximal number of vibro-transducers per channel:
Piezoelectric
up to 30
Electromagnetic
up to 7
Amount of subranges with a regulated power level of interference in 5
the channel
Frequency subranges
60... 350 Hz; 350... 700 Hz;
700-1400 Hz; 1400-2800
Hz; 2800... 16000 Hz
Type of interference
"white" noise; speech similar
interference of phoneme’s
clone; interference from an
external source; mixture of
a noise interference,
interference of phoneme’s
clone and interference from
an external source
Amount of independent phoneme’s clones
4
Amount of independent noise generators
4
Power supply
AC 220 V, 50 Hz
Overall dimensions
377х335х108 mm
Weight
8,5 kg
20
REMOVED COMMUNICATOR
BARON – DK
General:
For the control of efficiency of the vibrating handicapes
created vibroacustic by generators, such as "Baron" or the
similar equipment. The device provides the prevention of
reduction of the level of the vibrating handicap on
protecting design in the protected room below the
allowable one, as a result of failure of vibrators, the
generator of handicapes, change of environmental conditions. About twelve gauges are connected to
the device of the Baron – DK remote control (control devices of the Baron - K and Baron - K2 types),
carrying out set vi-brating signals from controllable protecting designs, their preliminary processing
and amplifica-tion. The Baron – DK device makes cyclic interrogation of gauges for the period less
than 1 with and comparison of signals acting from them with the established threshold values. If the
level of a controllable signal from any gauge of below given threshold the device develops a sound
alarm signal and displays the information on a source of alarm on the liquid crystal indi-cator.
Structurally the device is executed as the module of standard size U1 for installation in Rack-frames
(cases).
SECURE VIBRO-ACOUSTIC SYSTEM
BARON - S1
General:
For protection of the information discussed in office accommodations, against means of acoustic
speech investigation. Has two channels of formation of noise, the acoustic systems providing
transformation of an electric signal can be connected to each of which, formed by the device, in
mechanical fluctuations in protecting designs of the protected room, and also in acoustic fluctuations
of air chopper spiezoelectric or electromagnetic type, and also.
As noises in the device can be used:
• the signals formed by generators of noise;
• the signals formed phonemic clonners;
• a mix of the mentioned above types of handicapes.
Each channel of the device has the own independent generator of noise and phonemic clonners. It
allows to exclude an opportunity of indemnification noising the signal means of interception of the
speech information due to special processing, including correlation methods at multichannel set
several gauges. Phonemic clonners are intended for speech-like synthesis the handicapes optimized
for protection of the speech information of concrete persons.
Noising signal is formed by these sources of handicapes by cloning the basic phonemicprotected
persons making speech. Speech phonemes are allocated and enter the name in clonners with use of
PC. Vibrogenerator allows to use clonners as sources noising signal alongside with generators of noise.
For correction amplitude-frequency parameters of handicapes each channel vibrogenerator is equipped
two-way equalizer, that allows to form a handicap in view of resonant features of used vibrators, and
also elements of protecting designs. Adjustment and management vibrogenerator is made from
external PC manager on the consecutive interface. For prolongation of service life choppers are used
in the generator the system of soft switching on of the feed, excluding spasmodic increase of voltage
on the input choppers and acoustic systems.
Specifications:
Number noising channels
Target capacity
The Range of frequencies
Number of the vibrators connected to one channel
Quantity sub-band with an adjustable level of capacity of a
handicap in the channel
2
not less than 18 Wt on the
channel
60. 16000 Hz
piezoelectric - up to 20;
electromagnetic - up to 4
2
21
Frequency sub-bands
60. 1000 Hz; 1000. 16000
Hz
Types of a handicap:
Amount independent phonemic clonners
Amount of independent generators of noise
Range of adjustment of a level of a signal in each octava strip
Management of switching on of a handicap remote
"white" noise according to
requirements of normative
documents on Acoustic
Speech Investigation
Tech.comission of Russia;
speech-similar (formed
phonemic clonners of
vibrogenerator, way of clone
the basic phonemic
protected persons making
speech);
a mix noising handicapes
and handicapes phonemic
clonner
2
2
not less than 24 dB
interface RS-232
22
ANTITERRORIST
EQUIPMENT
23
SURVEILLANCE TV CAMERA WITH DAY AND NIGHT VISION AND ODAS CAPABILITY
GHOST SHADOW
General:
"GHOST SHADOW" is a handheld compact TV camera with
day-night vision and ODAS capability designed for long and
medium range counter-surveillance, optical objects
detection, selection and location of various targets despite
background clutter.
Features:
• Counter Surveillance
• Detects all known optical devices
• Day and night operation capability
• Can be operated in all weather conditions
• Making various objects visible despite background
This camera represents a state of the art integration of the
following units:
• Semiconductor laser illuminator
• TV channel contains Gen 3 Tube and highly sensitive TV camera
• Viewfinder
• Built in Li- Io TLS Smart Pack battery
• Electronic control system
All functions are controlled through simple menus with easy access to main operation buttons.
Operator receives an ergonomically sharp and clear images of the scene and generated information
(distance, illumination zone, operation modes, battery status etc…)
This unique device offers a comprehensive solution to meet customer’s various needs:
• Universal observation and counter surveillance for Police, Special Forces and Law Enforcement
Agencies
• Detection of opposing optics and location of threats for peace keeping troops, Border Guards, Anti
Terror combat missions, relief operations
• Day and Night vision and selection of objects in obscured weather for SAR missions, rangers, sea
monitoring and coast guard duties.
Can be used with tripod or pan and tilt mount. Can be remotely controlled from PC.
Specifications:
General
Weight
Dimensions
Main integrated features
Field of view
Illumination depth, imminent
Illumination depth, full
Recognition range within illuminated zone (With ambient light level
up to 1 000 lx)
Detection of optical targets with lens diameter (With ambient light
level up to 30 000 lx)
Display
Type
Color
Screen
Camera
Electrical
Power Supply
Autonomy (one battery)
Power consumption
Video output
1.8 kg
235x145x70 mm
5.5° x 4.1°
10, 20, 40, 400m
from 20 to 2 400m
for мan up to 400 m; for
truck up to 800 m
30 mm: up to 1 000m; 100
mm: up to 2 000 m
monocular
black and white
TV viewfinder
570 TVL
14,8V LiIon battery
up to 2.5 h
10 W
CCIR
24
Serial link
Environmental
RS232 (RS485)
Complies with IP 54
MULTICHANNEL GAS ANALYZER
COMBUSTIBLE GASES AND PAIRS SIGNALLING DEVICE
SIGNAL-03
General:
For measurement up to explosive concentrations of
multicomponent air mixes of combustible gases and pairs
(metane, prosir, butane, heptane, hexane, gasoline, diesel
fuel pairs and so on) and giving alarm when exceeding
defined level in the atmosphere of explosive zones.
It is applied to industrial premises; pump stations; tank
farms; the atomic power stations; oil, gas extracting,
processing enterprises; gas facilities; boiler-houses; and
also all the other objects where the continuous control over
collecting explosive fire-dangerous gases and pairs
concentration is necessary.
Features:
• compactness;
• multichannel;
• a wide list of controllable gases;
• operation simplicity.
• each channel of a gas analyzer-signalling device provides an opportunity of executive external
devices connection (siren, ventilation, for example).
Specifications:
Range of measurements of concentration, % LCL (the lower
concentration limit of flame distribution)
Alarms operating threshold
The basic error
Number of gauges
Alarms operating delay
The maximal distance between the information block and remote
gauges
Overall dimensions
Weight
0-45
20% LCL (light, sound)
5 % LCL
1-4 pieces
8 sec
100 m
the information block
240х21 8х100 mm; the
gauge 92х128х48 mm
the information block of 2,4
kg; the gauge of 0,2 kg
THE DEVICE OF ARMY CHEMICAL
INVESTIGATION
VPHR
General:
The device is used for detection and estimation
an infection danger degree with poison gases of
air, district, defense technology by means of
display tubes.
It defines determination of sarin, soman, vgases, yperite, phosgene, diphosgene,
hydrocyanic acid, cyanogen chloride in conditions
of moderated and cold climates with
25
temperatures from 400 up to -400 and relative humidity of air up to 100%.
Specifications:
Dimensions
Weight
Guarantee period of storage
length 220 mm; width 101
mm; high 160 mm
1,75 kg
5 years from the date of
manufacture are
established, except other
accessories, for which are
established such periods of
storage as: tubes for sarin,
soman, v-gases – 1,5 years,
cartridges – 2 years, lamp –
3 years, tubes for phosgene,
diphosgene, hydrocyanic
acid, cyanogen chloride - 4
years
VEHICLE MOUNTED BOMB JAMMING
KASKAD-3
General:
KASKAD-3 is a vehicle mounted modular radio signal
jamming system designed for defensive jamming of
radio controlled improvised explosive devices
(RCIED).
KASKAD-3 uses sophisticated RF technology and
transmits Fast Random Sweep interference signals.
This is a 13 band jammer with extended abilities that
interferes with signals in the frequency range of 20
MHz to 2500 MHz. Including cell phones – walkie
talkies – and satellite phones.
Using this unique technique KASKAD-3 creates
intensive barrage interference within the whole
frequency range and at the same time amplifies the
jamming signal on the 5 narrow frequency channels
which makes it more effective against the use of walkie talkies and cell phones – the terrorists’ choice
for remote control detonation. The system is suitable for mounting in any vehicle. The KASKAD series
of jamming systems offers protection to VIP in transit and military convoys. By effectively emitting a
protective shield of electromagnetic radiation, the target is protected against a terror attack with a
remote controlled improvised explosive device (RCIED).
Specifications:
JAMMING FREQUENCY RANGE:
INTERFERENCE TYPE:
INTERFERENCE CATEGORY:
OPERATION INDICATION:
INTEGRAL POWER:
POWER CONSUMPTION:
20-150 MHz; 150-500 MHz;
500-800 MHz; 800-1000
MHz; 1000-1400 MHz;
1400-1800 MHz; 1800-2000
MHz; 2400-2500 MHz; Sub
band with 3 targeted
narrowband channels; 2 Cell
phone targeted sub bands
Fast Random Sweep
Barrage
Lighted fault indicator
> 145 Watts
< 70 A
26
POWER SUPPLY:
TEMPERATURE RANGE:
OPERATING TIME:
WEIGHT:
INSTALLATION OPTIONS:
11-15V DC
-4/+122°F
Unlimited with engine
running
92.5 Lbs. (Equipment
without rack case)
In Vehicle, or Roof Mounted
Weather Proof Enclosure
COUNTERTERRORISM SECURITY FOR DIGNITARIES AND VIP
KASKAD-1
General:
The KASKAD-1 portable radio frequency jammer is a
system for defense against radio controlled
improvised explosive devices (RCIED). Transmitting
capabilities consist of independent channels with a
single power supply. The KASKAD-1 transmits Fast
Random Sweep interference signals. This is a multiband jammer with one fixed band between 20 and
500 MHz and two additional user selectable
frequency ranges.
Using an intensive electromagnetic field, the
KASKAD-1 emits powerful interference. This
interference covers the frequency bands listed below
and cannot be circumvented by filtering. This
interference prevents radio triggering devices from
activating.
The System can be customized to the client’s
requirements.
Specifications:
FIXED FREQUENCY RANGE:
SELECTABLE FREQUENCY RANGE (Operator can choose two of the
selectable bands for simultaneous operation):
INTERFERENCE TYPE:
INTERFERENCE CATEGORY:
ANTENNAS:
INTEGRAL OUTPUT POWER:
POWER CONSUMPTION:
POWER SUPPLY:
TEMPERATURE RANGE:
CHARGER
BATTERY OPERATING TIME:
OPERATING TIME FROM EXTERNAL POWER SOURCE:
WEIGHT
20-500 MHz
810-895 MHz or 925-960
MHz and 1805-1880 MHz or
1930-1990 MHz
Fast Random Sweep
Barrage
Built in or option for External
> 25 Watts
< 17A / 12V
95-265VAC 50/60Hz, or 1045 vDC
-4/+122°F
Built In
30 minutes
Unlimited
33 Lbs.
COVERT TRUNK MOUNTED BOMB JAMMING
KASKAD-4
General:
The Model KASKAD-4 is a modular Electronic
Countermeasure (ECM) System designed for the
defensive jamming of Radio Controlled Improvised
Explosive Ddevices (RCIEDs). The KASKAD-4 uses
sophisticated RF technology to transmit Fast Randomly
27
Swept Continuous Wave (CW) signals that interfer with the operation of the radio-controlled links used
to detonate the bombs. This multi-band jammer is comprised of seven (7) modules that jam all known
RCIED threats in the frequency range of 20 MHz to 2500 MHz. Specific threasts include VHF and UHF
Radios, Long-Range Cordless Phones, Cellular Phones, Satellite Phones, Remote Control Devices such
as RC Models and Wireless Actuators, Pagers and Walkie-Talkies. The KASKAD-4 provides contiguous
spectral coverage from 20 to 2,000 MHz and from 2,400 to 2,500 MHz; thus creating an intensive
barrage of interference over seven (7) frequency bands. The target is thus protected against attack
from RCIEDs by preventing the detonation of the associated explosive bomb. The system is suitable
for mounting inside any vehicle’s cargo area or within the trunk. It is powered directly by the existing
12-volt automotive electrical system if equipped with a high-output alternator. The KASKAD-4 is one
of a series of jamming systems that offers protection against radio-controlled roadside bombs to VIPs
and Military and Government Personnel.
Complete system fits inside the vehicle by the trunk (boot).
Specifications:
JAMMING FREQUENCY RANGE:
INTERFERENCE TYPE:
INTERFERENCE CATEGORY:
OPERATION INDICATION:
INTEGRAL POWER:
POWER CONSUMPTION:
POWER SUPPLY:
TEMPERATURE RANGE:
OPERATING TIME:
WEIGHT:
WEIGHT: 70 Lbs. (Approx)
20-150 MHz; 150-500 MHz;
500-800 MHz; 800-1000
MHz; 1000-1800 MHz;
1800-2000 MHz; 2400-2500
MHz
Fast Random Sweep
Barrage
Lighted fault indicator
> 200 Watts
< 70 A @ 13V
11-15 V DC
-4/+122°F
Unlimited with engine
running
70 Lbs. (Approx)
In a Vehicle Trunk, or Cargo
A SET FOR THE SAMPLE EXPRESS
ANALYSIS ON EXPLOSIVE SUBSTANCES
DESIGNATION
VIRAGE-VV
General:
Designed to locate and identify explosives by trace quantity on
packaging surfaces, clothes and also on other suspicious objects.
May be used to analyse samples both in field and laboratory
conditions.
Set - composition
• 3 flasks with systems with A, B, C - indicators;
• Filtered - paper cloths;
• Case.
Specifications:
Minimum Quantity of Discovered Explosives:
troty1
tetryl
hexogen
octogene
tetranitropentaerytrite
Analysis time
1х
1х
1х
1х
1х
not
10-8
10-6
10-6
10-6
10-5
more than 1 min
28
THE HIGH-SENSITIVITY PORTABLE GAS DETECTOR
ANALYZER WITH AIR AS A GAS-CARRIER
EHO-V
General:
For the express train-analysis of gaseous and
liquid tests on the maintenance of poison and
explosive substances.
Gives an opportunity to carry out the analysis of
poison and explosives with the use of standard
techniques , also to create and update databases
and conducting archives.
The management of the device and processing of
results of the analysis are made by means of a
computer.
Can be used for:
•
For the control of objects of environment,
premises, motor transport, luggage, items of mail.
• For the search of poison gases, explosives and
explosive devices.
• For the definition of the circle of persons who had contact with explosives and their automatic
identification.
Features:
• small weight and compact dimensions;
• low energy consuming;
• high sensitivity;
• high speed;
• an opportunities for distant sampling.
Specifications:
Detector
Devices of test
The limit of chromatograph detection:
The direct input of the air:
Sarin (GB)
Soman (GD9)
V-gases (VX)
Yperite (HD)
Lewisite (L)
ionic with reforming selectivity gas
chromatography pump
syringing input; input with volume of
sorbent 0.01-0.18 sm3; automatic gas
loop
non worse than 0,015 mg/m3, the time
of the analyze - not more than 60 sec;
non worse than 0,003 mg/m3, the time
of the analyze - not more than 60 sec;
non worse than 0,015 mg/m3, the time
of the analyze - not more than 70 sec;
non worse than 0,2 mg/m3, the time of
the analyze - not more than 70 sec;
non worse than 0,6 mg/m3, the time of
the analyze - not more than 30 sec.
With the use of syringing input and gas chromatography
syringe with the volume of 1 mkl:
Sarin (GB)
non worse than 6,0*10-6 mg/m3, the
time of the analyze - not more than 60
sec;
Soman (GD9)
non worse than 1,2*10-5mg/m3, the
time of the analyze - not more than 60
sec;
V-gases (VX)
non worse than 4,2*10-5 mg/m3, the
time of the analyze - not more than 70
sec;
Yperite (HD)
non worse than 7*10-5 mg/m3, the time
of the analyze - not more than 70 sec;
29
Lewisite (L)
Power supplies
Working temperature extension
Power consumption
Dimensions
Weight
Weight of the trier
non worse than 2,3*10-5 mg/m3, the
time of the analyze - not more than 30
sec.
snap-in battery 12V, 12A/hours (the
work time of the device); external
source of the direct current (output
voltage from 11 to 15 V; power rating
NLE 70 Wt; connection to the car
system or accumulator 12 V); external
source of the alternating current
(220/115 V, 50-60 Hz)
+5…+400C, range extension + 50.
no more than 70 W
500x135x330 mm
without inside accumulator – 6 kg, with
accumulator – 9 kg
1 kg
EXPLOSION PROTECTING DEVICE
FONTAN-2M
General:
It is designed for decreasing the high-explosive effect
from explosives, which weights are equal to 0,8 – 1 kg
of trinitrotoluene. It also decreases the effect from
high-explosive shells.
Specifications:
Dimentions
Height
Height of internal cavity
Weight without container
external diameter 540
mm, internal diameter
300 mm
270 mm
220 mm
35 kg
EXPLOSION PROTECTING DEVICE
FONTAN-3M
General:
It is designed for decreasing the high-explosive
effect from explosives, which weights are equal
to 0,8 – 1 kg of trinitrotoluene. It also decreases
the effect from high-explosive shells.
Specifications:
Dimentions
external diameter
750 mm, internal
diameter 420 mm
Height
400 mm
Height of internal cavity 300 mm
Weight without container 55 kg
30
MULTICHANNEL GAS ANALYZER OF INFLAMMABLE GASES AND VAPORS
SIGMA-1
General:
For measurement till explosion concentration of
multicomponent air mixes of combustible gases
and vapors (methane, propane, butane, vapors of
gasoline, diesel fuel), also for delivery or sound
and light signals of the notification and signals of
management for the disconnecting equipment at
excess of the set level of gas concentration in at
atmosphere of explosive zones.
It is applied to the equipment of industrial
premises where the constant control over
concentration of collecting explosive and
firedangerous gases and vapors is necessary.
Features:
• Digital indication of measurement results;
• Convenient microprocessor system of data
gathering;
• Two levels of the recustomized signal system in
a digital king;
• Handicaps protection;
• Data transmission in the central computer.
Specifications:
Range of measurement of gases and vapors
Basic error
Number of detectors
Time of operation of the signal system
The maximal distance between the informational
board and the detector
Dimensions
Weight
The first level – precautionary; The second
level
0.2% of the volume or 5% of the lower
critical limit of distribution
1-8
8 sec
3000 m
Informational board – 125x230x320 mm;
Detector in a variant of security IP – 5492x128x48 mm.
Information board – 5 Kg; The detector in a
variant of security IP – 40-0,4 Kg, The
detector in a variant of security IP – 54-0,2
Kg
31
SECURITY
INSPECTION
32
PROGRAMMABLE DOSIMETER
PM1203M
General:
The PM1203M is a multipurpose dosimeter designed for
measurement of ambient dose equivalent H*(10) and ambient dose
equivalent rate of gamma radiation H*(10).
The PM1203M continuously operates in an automatic mode of dose
and dose rate measurement from the moment of inserting the
batteries.
Period of the device operation from one set of batteries at normal
conditions is at least 1 year. Presetting of the alarm thresholds of
dose rate and dose by the user is provided for in the dosimeter. In
case any of these preset thresholds are exceeded this information is indicated in the LCD and audible
alarm signals are coming. The dosimeter also automatically counts time of dose accumulation. Energy
range of the device operation of 60 keV - 1.5 MeV, dose rate measurement, starting with the
background values (0.1 mSv/h) make it possible to control using the dosimeter the radiation
environment and radiation dose of the user not only at various operations with sources of ionizing
radiation but also even in conditions of slight natural background fluctuations. The dosimeter has the
shockproof plastic case, light weight and small dimensions. Rotary clip of a special design makes it
possible to fix the dosimeter in the pocket or to place it on the table.
The PM1203M is a modification of the well-known the PM1203 dosimeter. Having all advantageous
capabilities, specifications, weight and dimensions of the PM1203, the PM1203M excels its predecessor
in a number of parameters:
•
•
•
the limit of dose rate measurement is exceeded by 4 times (up to 2 mSv/h);
special algorithm provides decrease of the coefficient of variation;
temperature range is increased from -40 °C up to 60 °C; such function as storage of history of
dose rate, accumulated dose value and serial number of the dosimeter in its nonvolatile
memory and further transmission of these values to PC through IR-adapter using special
software, which is supplied under the order of a customer, is added. It makes it possible to
use the dosimeter as a component of computer system for accounting the doses of personnel
and for creating corresponding data bases.
The PM1203M provides measurement of ambient dose equivalent H*(10) and dose equivalent rate
H*(10) of gamma radiation and it can be used both by professionals and by a wide range of
customers. A special mode of initiation of dose rate measurement is additionally introduced into the
dosimeter. It makes it possible to use the device not only for continuous control of radiation situation,
but also at various types of radiation survey to perform and fix when necessary the control
measurements of dose rate (e.g. when sampling for measurement of specific activity, at measurement
of dose rate at working places, at checkup of the territories, etc.)
Specifications:
Detector:
Dose rate measurement range:
Dose rate threshold range [increment]:
Dose measurement range:
Dose threshold range [increment]:
Dose accumulation time range:
Accuracy:
± 20% [0.1 - 199.9 mSv/h];
± 30% [200 - 500 mSv/h].
Geiger-Muller tube.
0.1 - 500 mSv/h.
0.1 - 500 mSv/h [0.01, 0.1,
1].
0.001 - 9999 mSv.
0.001 - 9999 mSv [0.001,
0.01, 0.1, 1].
1 - 9999 h.
Energy response relative to 0.662 MeV (Cs-137) in the
energy range:
0.06 - 0.662 MeV:
0.662 - 1.5 MeV:
< ± 25 %;
< ± 15 %.
Energy range:
Measurement time is automatically set within the range:
0.06 - 1.5 MeV.
1 - 36 s.
33
Power supply:
Operating conditions: temperature range:
Batteries lifetime:
Dimensions:
Weight (with batteries):
2 batteries of V357 type.
-15 ... +50 0C.
1 year.
125 x 42 x 24 mm.
90 g.
WRIST GAMMA INDICATOR
PM1208
General:
The PM1208 Indicator is the result of wrist watches product line
development (PM1206, PM1207). It has preserved all the best features of
preceding models and gained a whole range of new advanced features.
PM1208 has new specially developed design, which completely change the
common vision of dosimeter. Highly persicion switcerland whatch module
Ronda 763 is a reliable warrant of up to second Indicator time readings.
Modern stainless case provides a water resist up to 100 m.
Electroluminescent backlight allowes easily control of instrument readings
in the darkness. Litium battery CR2032 provides up to 1 year continious
operations.
The PM1208 Indicator is designed for performing continuous control of
radiation condition in the environment, detection of contaminated places as
well as for accumulated dose accounting. PM1208 allows solving of the
main problem of human safety independent on where his lockation is.
This is a good choice for professionals and all those who takes care about
their personal safety and condition of the environment.
Specifications:
Detector:
DER registration and indication range [Step]:
Geiger-Muller tube.
0.1 - 4000 mSv/h [0.01;
0.1; 1.0; 10.0; 100].
DER threshold range (Upper limit of threshold is determined by the 0.001 - 9999 mSv.
life time of the battery being used):
DE threshold range [Step]:
0.01 - 9999 mSv [0.001;
0.01; 0.1; 1.0; 10.0; 100].
Accuracy of DER registration:
± 30 %.
Accuracy of DE registration:
± 25 %.
Energy range:
0.06-1.5 MeV.
Power supply:
CR2032.
Period of continuos operation of the indicator from one battery
12 months.
(CR2032) at natural radiation background, no less:
Quartz clock movement:
Ronda 763 (Switzerland).
Power supply for quartz clock movement:
SR 621 SW.
Period of energy independence of the quartz clock movement (from no less 36 months.
SR 621 SW battery):
Resistant to:
excessive water pressure:
up to 10 bar;
water resistant:
up to 100 m.
Operating temperature range:
Dimensions, no more:
Weight (without band):
0 ... +45 0C.
50 x 45 x 20 mm.
no more 95 g.
34
ALARMING RATEMETER
PM1401M
General:
The PM1401 is a unique highly sensitive alarming ratemeter designed for exploitation in the field
environment to detect and locate gamma-radiation sources and to measure gamma-radiation dose
equivalent rate. It features an increased sensitivity to weapons materials.
The unit meets the drop test (0.7 m, concrete surface) and sea fog test and has a low power
consumption (period of a continuous operation from one set of batteries is 1000 hours).
A special algorithm implemented in the device allows to search and locate even weak sources in the
fields of radioactive radiation, created by more intense
sources.
When the unit is turned on, it goes through a series of
diagnostic self-tests. Then the device measures
background radiation, calculates the alarm level
(depending on the background value and preset
coefficient) and enters into the search mode.
When the radiation from the source exceeds the threshold,
audible or vibration alarming device will trigger. The
frequency of signals increases with approaching the
radioactive source.
The PM1401 is one of the two devices in the world, which
has been successfully tested under the ITRAP program in
its class of pocket monitors and has the corresponding
certificate. Besides, it has also been tested at the Russian Federal Nuclear Center (Snezhinsk) and is a
regular device of the customs services of the Russian Federation, Republic of Belarus and Kazakhstan.
Specifications:
Detector:
Sensitivity*:
Measurement time:
Measurement range of the dose equivalent rate (DER)*:
Energy range:
Accuracy* (H is the dose equivalent rate, mSv/h):
Range of meansquare deviations:
scintillator CsI (Tl).
at least 100 cps/(mSv/h).
0.25 s.
0.05 - 40 mSv/h.
0.06 - 3 MeV.
± (20 + 0.20/H) %.
1 - 7.
Operating conditions:
temperature:
indication on the LCD in the temperature range:
-30 ... +50 0C;
-10 ... +50 0C.
Power supply:
4 AA ALKALINE batteries.
Battery lifetime, at DER up to 0.3 mSv/h, temperature from 0 to 50 1000 h.
0C, without audio and vibration alarms:
Drop test onto concrete:
0.7 m.
Dimensions:
86 x 125 x 30 mm.
Weight (with batteries):
400 g.
PERSONAL DOSIMETERS OF X-RAY AND GAMMA RADIATION
PM1621/PM1621A
General:
The PM1621/PM1621A dosimeters are professional instruments for
measurement of personnel dose equivalent Hp (10) and dose
equivalent rate Hp (10) of X-ray and gamma radiation within the
wide range of energies - from 10 keV to 20 MeV. Dose rate
measurement range for the PM1621 is here 0.05 mSv/h - 0.1 Sv/h,
for the PM1621A - 0.05 mSv/h - 1 Sv/h. Such energy range and
35
dose rate measurement range allow to control radiation situation and radiation dose of the user using
the dosimeter not only when working with sources of ionizing radiation of various intensity but also in
conditions of slight natural background's fluctuations. A function of storage of dose rate history,
accumulated dose value and serial numbers of the dosimeters in their nonvolatile memory and further
transmission of these values to PC through IR-adapter using a software is provided for in the
dosimeters. It makes it possible to use the dosimeter as a component of computer system for
accounting the doses of personnel and for creating corresponding data bases. The dosimeters meet in
full the requirements of the IEC61526 standard.
The devices allow the user to preset alarm thresholds on dose rate and accumulated dose (two
independent thresholds for dose and two for dose rate, which differ in type of audible alarm signals).
In case any of the preset thresholds is exceeded this information is indicated in the LCD and
corresponding audible alarm signal sounds. The dosimeters automatically count the time of dose
accumulation. Both dosimeters have shockproof hermetic housings thus making it possible to
decontaminate it. The dosimeters can be worn both in the breast pocket or attached to the belt.
PM1621
Specifications:
Detector:
Geiger-Muller tube.
Dose equivalent rate measurement range (DER) Hp (10):
PM1621:
PM1621A:
0,1 mSv/h - 0,1 Sv/h;
0,1 mSv/h - 1 Sv/h.
Dose equivalent rate indication range (DER) Hp (10):
PM1621:
PM1621A :
0,01 mSv/h - 0,2 Sv/h;
0,01 mSv/h - 2,0 Sv/h.
Dose equivalent rate threshold range:
Dose equivalent measurement range Hp (10):
Dose equivalent indication range Hp (10):
Dose equivalent threshold range:
Maximum permissible intrinsic relative error of DER measurement
(H - dose equivalent rate in mSv/h):
Maximum permissible intrinsic relative error of DE measurement:
Energy range:
Energy response relative to 0,662 MeV (Cs-137) within the full
energy range:
Time of response at discontinuous variation of DER (according to
IEC 61526), no more than:
5 s - at increase;
10 s - at decrease.
Coefficient of variation:
within all DER measurement
range.
1 mSv- 9,99 Sv.
0.01 mSv - 9,99 Sv.
within all DE measurement
range.
± (15 + 0,0015/H +
0,01H)%.
± 15%.
10 KeV - 20,0 MeV.
± 30%.
< 15%.
Survive after momentary influence of maximum permissible
gamma radiation:
PM1621:
1 Sv/h;
PM1621A:
10 Sv/h.
Additional functions:
Drop test on concrete floor:
Power supply:
Battery lifetime (at natural conditions):
Battery discharge indication (partial and critical):
PC communication mode.
0,7 m.
one battery PANASONIC
POWER LINE LR6 AA.
12 months.
LCD indication.
Operating conditions:
temperature:
from - 40 up to +60 0C;
36
relative humidity:
pressure:
up to 98 % at 35 0C;
from 84 up to 106,7 kPa.
Degree of protection provided by housing:
Dimensions:
Weight (with battery):
IP67.
87 x 72 x 35 mm.
no more than 150 g.
IR-adapter
Data transmission rate:
Maximum distance for data transmission:
Connection of the adapetr to PC:
Operating temperature range:
Dimensions:
Weight:
Software:
9,6 Kb/s.
20 cm.
RS-232 (9 pin).
0 ... +40 0C.
51 x 41 x 16 mm.
54 g.
CD.
EXPLOSIVE VAPOUR DETECTOR
PILOT-M
General:
Pilot-M Detector is intended for non-hermetic environment
and cavities investigation for explosive scents and explosives
residue detection on a questioned item surface. It might be
luggage, vehicles, clothes and even passport or other
document of a suspected person.
Operational principle
The Pilot-M operational principle is based on Drift
Spectrometry method (IMS) in an alternating electric field.
Explosives vapor detection is realized by assay collection
from the suspect object surface or its inner space and
subsequent analysis of these samples for the presence of
typical componentry.
Features
•
•
•
•
•
Explosives detection in non-hermetic environment
Explosives residue detection on a questioned item surface
Detection of less volatile matters and compositions on their base (plastic explosives)
Sample collection in a dusty and smoky environment
Simultaneous sample collection in various places by means of remote Sampler
Specifications:
Threshold sensitivity (TNT):
Response time on explosive vapour:
Sampling distance:
Operating temperatures:
Power supply:
Weight (including battery):
not worse 10-13 g/cm3.
no more 1 sec.
up to 10 cm.
5 to 45 °C.
100...240 V / 47...63 Hz (via
12V adapter - supplied); 6 V
(2 rechargeable batteries supplied)
2 kg.
37
PORTABLE METAL DETECTORS
AKA-SERIES
General:
The device detects the presence of various metal objects
in dielectric environment. It can be used for exploring
buildings, furniture, and clothing for detecting guns or
bugs. The device has high sensitivity for the different
objects and a built-in system of sensitivity level automatic
maintenance. It can be detected from small metal pieces
till complex metal objects.
Product Range and features
• AKA 7202 - heightened sensitivity.
• AKA 7215 - ferrous/non ferrous metal selectivity.
Specifications:
Operation in battery mode:
Dimensions:
Weight:
Indication:
700 h.
380 x 140 x 34 mm.
280 g.
visual/audible.
INDUSTRIAL FIBERSCOPES
AT-SERIES
General:
AT-series - it’s a wide range of flexible
fiberscopes available to suit the ever demanding
range of industrial and security applications. ATseries are intended to view areas that are difficult
to access including those of them that are closed,
obscure and characterized by small input orifices.
There are many extra benefits available such as
tapered flexibility insertion tubes, fixed focus,
angulation and interchangeable tip adaptors thus
providing maximum versatility.
Also the devices may be equipped with back-light
units operating from either mains adaptors or
rechargeable batteries. A set of the batteries is
supplied with a charging unit operation time in
conjunction with the batteries set-aided backlighting exceeds 2 hours.
So as to perform documenting and attain easy viewing the devices may be complimented by either a
camera or a television appliance. All these features offer an ideal tool for non-destructive inspection in
confined areas without the need to disassemble the object thereby saving time and money.
Product Range
Model
Function part
length (mm)
Function part
diameter (mm)
Aberration angle
(degrees)
AT 10-1.2 1200
10
+/-180
AT 10-1.5 1500
10
+/-180
38
AT 10-2.0 2000
10
+/-180
AT 8-1.2
1200
8
+/-180
AT 8-1.5
1500
8
+/-180
AT 8-2.3
2300
8
+/-180
AT 6-1.2
1200
6
+/-180
AT 6-1.5
1500
6
+/-180
AT 6-2.0
2000
6
+/-180
AT 4-0.5
500
4
+/-180
AT 4-1.0
1100
4
+/-180
Options
•
•
•
•
Opt.AT-01
Opt.AT-02
Opt.AT-03
Opt.AT-04
-
AC power supply.
Battery power supply.
Carrying case.
CCTV-unit.
INDUSTRIAL BOROSCOPES
ATG-SERIES
General:
A range of Industrial Boroscopes has been
developed using innovative technology to provide
large, bright, clear high resolution images.
Through innovative design, balancing the many
optical and mechanical requirements, optimum
results have been achieved resulting in superb allround performance when used by eye or with
CCTV. Ergonomically designed handle, optical
scan, variable focus, robust construction and
protected tip window are making these devices
suitable for a wide range of applications. Series of
Industrial Boroscopes are available with different
diameters, working lengths and vision angle.
Model
Function part
length (mm)
Function part
diameter (mm)
Visual angle
(degrees)
ATG 1.7-2 160
1.7
0, 90
ATG 2-2
160
2
0, 90
ATG 3-2
160
3
0, 30, 90
AT 4-3
160
4
0, 30, 70, 90
Options
•
•
•
•
Opt.AT-01
Opt.AT-02
Opt.AT-03
Opt.AT-04
-
AC power supply.
Battery power supply.
Carrying case.
CCTV-unit.
39
MULTIPURPOSE RADIATION MONITOR WITH IDENTIFICATION CAPABILITIES
PM1401K IDENTIFIER
General:
PM1401K Multipurpose Radiation Monitor with Identification
Capabilities is the first pocket monitor in the world to fulfill each
radiation control procedure. In addition to being able to detect
radioactive and nuclear materials, measure the radiation and surface
contamination levels and search for and locate the radiation sources,
the PM1401K Multipurpose Radiation Monitor can also identify the
radiation source.
The PM1401K performs the following functions, it:
• Detects, searches for, locates and identifies alpha, beta, gamma
and neutron radiation sources
• Measures alpha and beta surface contamination
• Measures the photon dose rate
• Alerts the user to the presence of a radiation source through both audible and vibrating alarms
• Records and stores up to 500 event and 100 gamma-spectra in its non-volatile memory
• Transmits all recorded data via infrared or radio (Bluetooth) channels to a PC or an iPAQ Pocket PC
The PM1401K is particularly effective as its user can be at a safe distance from possible radiation
sources while the instrument is operating. The instrument records the spectra and other information
that is transmitted instantaneously from the instrument to an iPAQ Pocket PC by a Bluetooth or
infrared channel. In that way, the instrument's operator is protected from radiation exposure.
Additionally, the PM1401K is particular effective as it can identify detected radiation sources equally as
well in the field as in a laboratory environment.
A special software package called the "Smart 2003" is included with each instrument for spectra
interpretation and source type identification. Both automatic and expert modes are available.
Together, the instrument's small, hermetic and shockproof case and the fluorescent backlight on the
instrument's LCD screen allow for easy operation even in the harshest, most unfavorable
environments or weather conditions.
PM1401K can also be equipped with various functional accessories, including:
• External Vibration-Alarming Device that allows the instruments user to be notified discreetly of
potential radiation sources without drawing the attention of observers
• Telescopic Extendable Tube, which allows the instrument to take measurements in otherwise
difficult-to-access areas and ensures a high degree of radiation protection for the user
• External Neutron Moderator to increase the neutron sensitivity by a factor 10.
Specifications:
Detector
Sensitivity, no less than
On 241Am
CsI(Tl)
2 (s-1 / mR/h) (200 (s-1 /
mSv/h))
On 137Cs
2 (s-1 / mR/h) (200 (s-1 /
mSv/h))
Energy range of gamma radiation
0,06 - 3,0 MeV
Energy range of gamma radiation according to special order
0.03 - 3.0 MeV
Coefficient n setting range, (the number of mean square deviations 1.0 - 9.9
of background)
The number of accumulation channels of the scintillation spectra
1024
The number of spectra, stored in non-volatile memory
to 100
Detection of gamma radiation sources at a distance of 0.7 ft
(0.2m), velocity of 1.64 ft/s (0.5 m/s) and level of radiation
background of no more than 25 mR/h (0,25 mSv/h) when the
activity of the sources is:
133
Ba
55.0 kBq
137
Cs
100.0 kBq
60
Co
50.0 kBq
Detection of the sampling sources at a distance of 0.7 ft (0,2m),
velocity of 1.64 ft/s (0.5m/s) and level of radiation background no
40
more than 25 mR/h (0,25 mSv/h) when the weight of the sources
is:
Pu
U
Neutron search channel PM1401K-Identifier
Detector
Energy range
Coefficient n setting range, (the number of mean square deviations
of background)
Detection of the 252Сf alternative source with neutron flux 1,5х104
s-1 at a distance of 3.28 ft (1 m), velocity of 1.64 ft/s (0.5 m/s)
and the level of radiation background of no more than 25 mR/h
(0.25 mSv/h), equivalent of plutonium
Measuring gamma-channel PM1401K-Identifier
Detector
Dose equivalent rate measurement range (DER)
Energy range
Energy response relative to 0.662 MeV (137Cs) in the photon
radiation measuring mode, (%) no more:
-within the energy range from 0.015 up to 0.045 MeV
-within the energy range from 0.045 up to 15.0 MeV
The allowable limits of the main relative error of DER measurement
(where H is the DER value in mSv/h)
Measuring alpha and beta channel PM1401K-Identifier
Detector
Alpha-flux density measurement range of
Alpha-flux density measurement range of the minimal detectable
flux density
General specifications of the instrument PM1401K-Identifier
Identification of radionuclides:
- Special nuclear materials
- Medical radionuclides
- Naturally occurring radioactive materials
- Industrial radionuclides
Alarming devices
Data transfer communication channels
Battery lifetime
Battery
Operating conditions:
temperature range
relative humidity at 95 °F (35 °С)
Protection degree
Weight
Dimensions
0.01 oz (0.3 g)
0.35 oz (10 g)
Slow neutron counter
0.025 eV - 14 MeV
1.0 - 9.9
8.8 oz (250 g)
GM-counter
10 - 107 mR/h (0.1 - 105
mSv/h)
0.015 - 15 MeV
±40%
±30%
± (15 + 0,0015/H) %
GM-counter
from 15 min-1*cm-2 to 105
min-1*cm-2
from 2 min-2*cm-1
233
U, 235U, 237Np, Pu
67
Ga, 51Cr, 75Se, 99mTc,
103
Pd, 111In, 123I, 125I, 131I,
201
Tl, 133Xe
40
K, 226Ra, 232Th, 238U and
other
57
Co, 60Co, 133Ba, 137Cs,
192
Ir, 204Tl, 226Ra, 241Am
visual (LCD), audible builtin, and external vibration
IRDA (IR-channel);
Bluetooth (radio-channel)
600 h
AA
-22 ... +122 °F (-30 ... + 50
°C)
up to 95 %
IP65
22.9 oz (650 g)
9.5’’ x 2.3’’ x 2.3’’ (242 х 58
х 57 mm)
41
WRIST GAMMA DOSIMETERS
PM1603A / PM1603B
General:
PM1603A and PM1603B Wrist Gamma Dosimeters are miniature, energycompensated dosimeters designed to monitor the gamma radiation
environment as well as monitor the gamma radiation dose and dose rate.
The instruments' ability to compensate for varying energies allows these
wrist gamma dosimeters to accurately measure the dose and dose rate of
gamma radiation in a wide energy range.
Recommended to protect professionals who work with or around radioactive
materials from accidental exposure, the PM1603A and PM1603B perform
the following functions, they:
• Monitor and measure the gamma dose and dose rate across a wide
energy range: from the natural background level up to 5-10 Sv/h (5001000 R/h).
• Alert the user through an audible alarm when the programmed dose and/or dose rate thresholds are
exceeded.
• Record and store data for up to 1000 events in their non-volatile memory.
• Transmit all recorded data via an infrared channel to a PC for further processing and analysis.
To protect users from overexposure, the dosimeters have two alarm thresholds. If the preset dose and
dose rate thresholds are exceeded, the dosimeter immediately alerts the user to the danger of
irradiation through an audible alarm.
The instrument's hermetic and shockproof case and the LCD screen's fluorescent backlight allow for
easy operation and precision even in the harshest, most unfavorable environments or weather
conditions.
Specifications:
Detector
Dose rate measurement range
Geiger-Muller tube
1 mSv/h - 5.0 Sv/h (100
mR/h - 500 R/h) PM1603A; 1 mSv/h - 10.0
Sv/h (100 mR/h - 1000 R/h)
- PM-1603B
Dose rate indication range
0.01 mSv/h - 6.50 Sv/h (1
mR/h - 650 R/h) - PM1603A; 0.01 mSv/h - 13.0
Sv/h (1 mR/h -1300R/h) PM-1603B
Dose rate and dose threshold range (two threasholds)
all operating range
Dose measurement range
1.0 mSv - 9.99 Sv (100 mR
- 999 R)
Dose accumulation time count range
1 - 9999 h
Dose Rate Accuracy (H is the dose equivalent rate, mSv/h)
± (15 + 0.02/H + 0.003H)
%
Dose Accuracy
± 15%
Energy range
0.048 - 3 MeV
Energy response in the full energy range
± 30%
Water resistant to momentary submerging
3.28’ (1 m)
Survive after momentary influence of maximum permissible gamma 5000 R/h (50 Sv/h) - PMradiation within 5 min:
1603A; 10000 R/h (100
Sv/h) - PM-1603B
Calendar mode
day of the week, date,
month, year
Functions
alarm clock, timer, stop
watch
Adjustable timer periods range
1 s - 23 h 59 min 59 s
Stop watch periods range
0.1 s – 23 h 59 min 59 s
Daily variation of watch at normal conditions
± 0.5 s/day
Power supply
One CR 2032 Lithium
42
Battery lifetime
Battery discharge control
Operating conditions:
-temperature range
-relative humidity (at 95°F (35°C))
-pressure
Degree of protection provided by housing
Dimensions:
Weight (with battery)
battery
9 month
Pictogram on LCD
-4 ... +158 °F (-20 ... +70
°C)
up to 98%
12.18 - 15.48 psi (84 106.7 kPa)
IP67
2.0’’ x 2.2’’ x 0.8’’ (50 x 56
x 19 mm)
3 oz (85 g)
DIGITAL RADIOGRAPHIC SCANNER FOR PERSONAL EXAMINATION
CONTOUR
General:
In modern conditions only use electromagnetic
metalicdetector for examination of the person and x-ray
systems for examination of luggage any more does not
provide a required level of safety and the control. First of
all it concerns a safety at the airports and the customs
control on border when for fulfilment of acts of terrorism
the cold nonmetallic weapon is used, a plastic explosive, is
carried out illegal перевоз drugs in the swallowed capsules.
Besides the problemof increase of a level of safety is
important: on border with the states in which there are
confrontations, on protected objects, for the VIPs, on
mines and the enterprises connected with extraction and
processing of diamonds, jewels and metals, rare-earth
elements. The main problem is that instruments of
terrorism and the subjects forbidden to transportation, can
be from nonmetallic materials and to be hidden not only
under clothes, but also in natural cavities of a body. For
today essentially new means of the control become the
digital scanning systems of the person based on use of xray radiation.
Technology scanning digital roentgenography for
good safety:
The Unique technology of reception of the digital projective x-ray image of the person in full growth by
a method of " scanning by a flat bunch(beam) " is based: on use as the receiver of x-ray radiation of a
superhigh-sensitivity linear matrix semi-conductor scintillation the detectors located vertically; on
formation extremely narrow (less than 2 mm) monochromatic a x-rays with the help of system
collimators and filters with the purpose of the minimal irradiation of the controllable person; on
moving of the person on the special moving platform located between collimator and the detector
through a x-rays, with the purpose of scanning and personal inspection; on detecting of past radiation
through the person with the help of the linear detector and formation of a two-dimensional matrix of
the digital image on the monitor of the operator; on optimization of the doze ratio of an irradiation
and resolution depending on specificity of a decided problem. The digital x-ray scanner working on this
technology allows to receive the projective image of the controllable person and actually enables " to
glance inside " the person c the purpose of personal inspection. Thus there is no obvious problem of
the ethical plan, characteristic for scanning x-ray systems on the basis of the reflected radiation which
as though " undress the person ". Besides it is not required two scannings - in front, behind and
sideways in a number of the cases for examination of the person.
The radiographic scanner is intended for detection of dangerous subjects:
• from the inorganic materials hidden under clothes fire and a cold steel, detonators, electronic
devices etc.;
• from organic materials (materials, not detecting the detector of metals), hidden under clothes - a
plastic explosive, drugs in containers, fire and a cold steel from ceramics etc.;
43
• from materials of any types swallowed or hidden in natural cavities of the person - drugs, explosive,
chemical and biological substances in containers, jewels and metals.
The basic scopes:
At the airports, at railway and bus stations for good safety mass passenger transportations; on
protected objects with the purpose of the entrance / target control; in prisons, as alternative to
personal inspection (strip searching).
Additional scopes:
On border with the purpose of customs inspection for detection of smuggling; on mines and factories
on extraction of diamonds with the purpose of prevention of plunders; in shops on operational
development and processing of diamonds, jewels and metals, concentrates rare-earth elements with
the purpose of prevention of plunders; a safety the VIPs.
Safety:
The doze of irradiation of the person at one scanning: in a mode the ultralow doze does not exceed
0,1 items; in a mode the high sanction does not exceed 3-5 items. In radiating safety the system
corresponds the American national standard ANSI/HPS N43.17-2002 " Radiation Safety For Personnel
Security Screening Systems Using X-rays ".
Safety the scanned person:
For the comparison, the typical doze of an irradiation caused by space radiation, the person making
flight one way from Malaga to London, makes 10 items, of New York to London - 35 items and from
Hong Kong to London - 50 items. The typical background doze of an irradiation received by the
average representative of the countries of the European Union per day, makes 6-7 items. Thus, the
irradiation to which the person on scanning x-ray system is exposed, is unsignificant on a background
of natural radiating radiation. The presence(finding) on the sun or any flight by the plane brings the
greater contribution to the general(common) irradiation of the person in tens times. According to
recommendations of the American national council of radiating protection (NCRP 1993) And to the
international norms of safety for the general(common) contingent of the population (pregnant women
and children among them) we admit the level of an irradiation in 1000 items per one year from all
sources ionizing radiations of not medical purpose. If to assume as a basis value in four times smaller
- 0,25 item on the given system even pregnant women and children without harm for health can be
exposed up to 2500 scannings per one year, that, obviously, it is unreal from a reason of common
sense. At use of the scanner on protected objects with carrying (on special cards) system of access
(for example, on diamond mines and factories), it is not difficult to organize the control of the
personal saved up doze. In this case, even at work of system in a mode of the high sanction, the
general number of inspections on system can make from above 300 once a year and examination
within one year can be organized so that not admit the excess of the saved up doze. Objectively, it is
quite enough for good safety in view of presence of the rigid control and the limited number of
visitings of any protected object.
Safety for the operator:
The System can cope, as one, and several operators. In case the operator is within the limits of a
working zone on distance less than 1,5 m from the scanner his(its) protection on a workplace is
provided with the help of a special protective screen from a lead glass that allows to observe of the
controllable person. The doze received by the operator outside a working zone, does not exceed a
typical background doze of an irradiation, and additional protection against x-ray radiation is not
required.
Safety for associates:
Outside a working zone on distance more than 1,5 m from the scanner the level of x-ray radiation
does not exceed background value and consequently does not represent any danger to associates. It
allows to place scanning system on the compact area in places of a mass congestion of people, for
example, at the airports near to customs system of luggage.
Specifications:
Characteristics of the digital image
The Size of the digital image (a field of scanning)
The Format of a matrix of the image, pixels
2000x800 mm (a ultralow
doze); 2000x800 mm (the
high sanction)
672 х 275 (a ultralow doze);
2688x1100 (the high
sanction)
The Spatial sanction
44
low-contrast objects
high-contrast objects
Time of scanning
Average time of viewing of the image
Physical characteristics
Dimensions
Characteristic of the x-ray generator:
The Working anodi voltage
the Working anodi current
of 5-7 mm (a ultralow
doze); 1-2 mm (the high
sanction)
of 0,3 mm (a ultralow doze);
0,2 mm (the high sanction)
8 sec (a ultralow doze); 16
sec (the high sanction)
5 (a ultralow doze); 10 (the
high sanction)
2100 x 4500 x 2400 mm
160 kW
2.5 mA
EXPLOSIVE VAPOUR DETECTOR
MO-2M
General:
For detection vapors explosives at
operative inspection of various objects,
including in field conditions.
It is applied to detection and identification
of type of explosives at maintenance air,
automobile, water and railway transport.,
offices and premises.
The product is completed by the display
which serves for a conclusion of more
exact information about the device’s
condition and investigated object. (Shows
on the screen the message about the type of explosives.)
The structure of the device provides system of automatic lock-out, therefore change of humidity or
temperatures of air do not render influence on process of the analysis.
Specifications:
Types of detective substances
Sensitivity
Time of reaction for vapors
Distance of making sampling
Indication of detection
Calibration
Range of working temperatures
Time of continuous work
Weight
Dimensions
TNT, NG, cyclonite, oktogen,
semtex
not more than 10-13
grams/centimeter
nothing more than 2 seconds
till 10 centimeters
light, sound
automatic
from 50C till 450C
with storage battery – NLE 3
hours; all-mains 110-220
volts, 50/60 hertz - nothing
more than 23 hours
the detector – 1,3 kilograms,
the complete set in packing
– 5,2 kilograms
the detector – 310X100X90
millimeters, the complete set
in packing – 355X280X110
millimeters
45
SOFTWARE
SOLUTIONS TEST
& MEASUREMENTS
46
MULTIFUNCTION RADIOMONITORING SOFTWARE
PATROL
General:
The product is designed to create on its basis
software & hardware RF monitoring systems with
the capability to post-process the monitoring
results.
The system may include hardware, which perform
RF monitoring, and the PATROL as data processing
and controlling software. The consumer oriented
system allows to use a wide range of equipment
starting from the simplest scan receivers up to
measurement devices by leading worldwide
manufacturers. Hardware control, collection,
storage, processing, data presenting, control of all
operation modes of the system is effected by the
PATROL package.
The package makes it possible to control 2 RF
receiving units simultaneously. A scan receiver by
ICOM and AOR Co. Ltd or spectrum analyzer by
Hewlett Packard 859х series, ESA-E and ESA-L can
be used as the main unit. Any of the above
mentioned scan receivers can be applied as the second unit designed for listening and recording audio
data.
The main operation principle of the software package “plug & play” means minimum time for setting
tasks and processing results. The most part of operation is made by PC.
So, reliable and trustworthy data can be gained even by a non-highly-qualified operator.
For successful operation of the software package you need to have IBM-combined PC (P-166 and
more), Windows 95/98, video-card with the resolution not less than 800 x 600, GP-IB port (to work
with spectrum analyzers with the use of IEEE-488 protocol, free serial port (to work with receivers or
spectrum analyzers with the use of RS-232 port), sound-card and acoustic speakers.
PATROL has a flexible, informative interface displaying the system operation process, signal
characteristics, intermediate results of their analysis. Now in the same environment there are RF
monitoring results database, interacting with frequency assignment data base, post-processing, vector
maps, report documentations.
That allows to use the package for solving a wide range of RF monitoring applied tasks, such as
signals with automated identification and placing in the database; detected signals parameters
measurement, detecting radiation parameters alarms compared to the set norms; scrolling frequency
bands or groups of RF electronic facilities or communication systems with different parameters of
radiated signal, load evaluation of frequency range and intensity of fixed frequencies usage; automatic
and manual record of LF signals; phonogram analysis in such modes as oscillograph, spectrum
analyzer, spectrogram; automated forming complex assignments on monitoring and measurements;
automated report making. Available vector maps allow to work with RF monitoring mobile stations, to
select RF electronic facilities on a certain territory and analyze their operation.
By consumer’s demand the product can be supplied along with GPS-receiver and electronic maps of
the needed region.
PATROL can be easily modernized for the consumer’s requirements, as well as adapted for the type of
equipment which is available at the user’s disposal.
Options
•
•
•
Opt. Pt-01 Database for storing results of radiomonitoring
Opt. Pt-02 Module for spectrum analyzer controlling
Opt. Pt-03 Module for GPS receiver controlling
47
SIGNAL ANALYZER & RADIOMONITORING SOFTWARE
FILIN-ULTRA
General:
Is designed to create on its basis software & hardware
systems to monitor radio air as well as search and locate
facilities for unauthorized acoustic data pick-up (including
video cameras, transmitting data over RF channel). This
software is the advanced version of the FILIN search
software. Besides searching RF bugs it can solve the
following RF monitoring tasks:
•
•
•
•
•
•
frequency range;
fixed frequencies monitoring;
frequency net monitoring. Operation algorithm of
the program, while solving RF monitoring tasks, is
very simple. If a signal is detected, the following
steps are performed:
a phonogram of demodulated signal is recorded;
clarifying scanning of the signal as well as record of its parameters in the database are made;
the certain program, which makes the steps you need, is started by the operator.
Phonogram record parameters, scanning conditions and start of your program can be easily
configured, that lets create on the base of the FILIN-ULTRA software RF monitoring systems for any
purpose (for example, creation and filling data base of your format and access up).
Own database of detected RF signals parameters allows to store a great number of parameters of the
RF signals detected and present them in symbol and graphical form (for example, diagrams of signal
spectra with curves of maximum, minimum, and average values of the signal on all records of this
signal, 3-dimensional presentation of saved signal spectrum, time-level diagram, etc.). Diagram
database makes it possible to store scanning diagrams of the entire frequency band, supported by the
used facility (the software lets store data in the frequency range from 0 Hz to 340 GHz with the
solution of 1 kHz) and simultaneously to display diagrams of current measurements, diagrams of
minimum, maximum, average values, standard diagram, as well as the difference of any 2 above
mentioned diagrams.
The diagrams can be viewed in a special window with scrolling band, which has a programmable
bandwidth. So, it’s possible to visually monitor the continuous frequency band, supported by the used
hardware.
Algorithms of obtaining, storage, processing and presenting data allow to monitor registered and find
unregistered RF signals, measure their parameters and follow the “Life history” of RF signals detected
before but lost during the current scanning.
All the above allows to apply FILIN-ULTRA software for solving a wide range of RF monitoring tasks,
monitoring RF air and searching RF bugs.
There can be another option of FILIN-ULTRA without solving a task of RF bugs search.
SIGNAL ANALYZER SOFTWARE
FILIN
General:
The program is designed for creation on its basis the
solutions for sweep and localization of acoustic data
unauthorized pickup devices as well as RF transmitting and
video surveillance. It is envisaged a possibility of data
transmission digital channels’ classification which greatly
simplifies digital RF bugs detection.
Hardware, directly performing unauthorized radiation
devices’ search and the FILIN control program are included
into the system. Wide range of scanning receivers can be
used as a hardware. FILIN program monitors the hardware,
data capture, storage, treatment and its representation
along with management of all system’s operation modes.
48
To identify the RF bugs the program employs different kinds of tests such as active, passive,
parametric as well as external passive tests implemented on the hardware basis are also accessible in
case of specific fast panorama analysis’ hardware employment. An outcome of the each test’s
execution supplies a quite detailed data on either presence or absence of the RF bug. Joint use of the
tests makes it possible to attain much more detection probability at lower erratic alarm generation
possibility.
Leaving for the user only a concern of initial system’s configuration specification, the program avoiding
an operator’s participation may perform all necessary parameters’ settings of the employed hardware
and management functions up to ultimate outcomes printout to attain an optimal tasks solution.
Alternatively the program’s feature is presence of flexible data interface indicating the system’s
operation process, signals’ parameters, intermediate outcomes of their analysis. The above interface
offers to the skilled operator upon his (her) wish an ability to conduct a detailed analysis of accepted
signals according to their spectral components, oscillograms, correlation functions and other
parameters. The above programme’s feature is useful for the RF monitoring’s various applied tasks’
resolution.
Features
•
•
•
•
•
•
•
•
reliable detection of any facilities for acoustic data unauthorized pickup, including spectrum
inversion;
RF transmitting video cameras detection;
up to 8 (!) progressive detection algorithms used simultaneously;
automatic classification of digital data transmission channels that conciderably simplifies
detection of digital “bugs”;
capability to connect any scanning receivers and spectrum analyzers that have computer
interface;
operation under control of Windows 95/98/NT operating systems;
capability to increase the number of system features due to using special instant trace
analysis equipment;
easy to use, “plug & play” principle.
INTELLIGENCE SOFTWARE
X-FILES
General:
As estimated at least 80 % of data theft is
committed by staff. The above program is
developed to control the staff’s observance of the
safety remote host utilization rules as well as to
reveal and stop attempts of unauthorized access
to confidential data.
The program enables to perform surveillance
over actions taking place during the operation in
the local network.
The program’s principle of operation is based
on latent “photographing” of the PC’s screen
display in certain interims. It is possible to record
both date and time of the picture. In every shot besides the graphical information there is a list of
processes and a list of windows.
Afterwards the pictures are compressed thus forming a “movie” that may be looked through either
in a whole, or separately shot by shot. Also there is a mode of viewing the remote host’s screen in real
time. The program is set into a controlled host and operates latently. Upon a necessity of looking
through of cumulated data one may watch the shot pictures via a supplied specific control program
that may be initiated separately from its own compact disk. The shot pictures may be copied and
transmitted over the network.
49
The program of data storage employs original technique of protection against countersurveillance,
unauthorized use and random operation.
Features
The network version of the program is intended to protect corporate networks against staff’s abusive
behavior enabling to set surveillance modules in any amount of workstations and to watch surveillance
results from any PC of the network.
When a routine work is underway on the controlled host the X-Files will mention it but in case of
someone had turned on the host so as to know or copy stored confidential data, to unauthorized use
the resources (e. g. Internet, Intranet, etc.), to irrationally spend the work time (computer games,
etc.) you will forthwith be aware of it and be able to take timely measures.
SHF CONVERTER
PS-SERIES
General:
Converter is intended to broaden a frequency range of any scanning RF
receivers, interceptors, spectrum analyzers and electromagnetic field
indicators. Its design consists of a portable aerial and an electronic assembly
to be directly connected to a receiver’s aerial input. The principle of
operation of an instrument is based on bringing of widened frequency ranges
into a receiver’s working range.
Product Range
Model
Frequency range Sensitivity
PS 6000
2000...6000 MHz
not less 1 miliV 0.000005
PS 5700
1900...5700 MHz
not less 1 miliV 0.000005
PS 3900
1300...3900 MHz
not less 1 miliV 0.000005
Frequency reference
PS 10000 6000...10000 MHz not less 5 miliV 0.000005
PS 7800
2600...7800 MHz
not less 1 miliV 0.000005
PS-6000 (typical)
50
Specifications:
Operation frequencies range:
Input sensitivity:
Output impedance:
Stagnant wave ratio:
A rebound value for a frequency bang of:
Power requirements:
Continuos operation time when using alkaline batteries:
Weight without the batteries:
2000...6000 MHz.
1,5 mV.
50 Ohm.
not more than 2.
200...300 kHz.
3 AAA size batteries (3 x 1,5
V).
not less than 20 hours.
500 grammes.
Dimensions of components:
electronic assembly:
aerial assembly:
100 x 30 mm;
210 x 80 mm.
Dimensions of the device: 310 x 80 mm.
ANTENNA MEASUREMENT SYSTEM
SHF-SERIES
General:
The system is intended for measuring electric magnetic
emanation within the frequency range from 1 to 26 GHz.
It can operate both indoors and outdoors.
Supplied with
•
•
•
•
•
•
Measurement antenna system SHF-1:
o super-wide-band logoperiodic vibrator
antenna LPVA-8;
o low-noise amplifier for the frequency
range 1-8 GHz (MSHU-1-8).
Measurement antenna system SHF-2:
o horn antenna RA-8-26;
o wave-conducting transfer from section
23 х 10 to section 16 х 8;
o wave-conducting transfer from section 16 х 8 to section 11 х 5,5;
o low-noise amplifier for the frequency range 8-12 GHz (MSHU-8-12);
o low-noise amplifier for the frequency range 12-18 GHz (MSHU-12-18); low-noise
amplifier for the frequency range 18-26 GHz (MSHU-18-26).
Unified power supply unit.
Unified antenna fixing point.
Connecting UHF-cable (VCHK-1; VCHK-2; VCHK-3).
Packed in a case.
51
•
The brief technical guide and user's guide.
Gain Figure (typical)
Specifications:
Frequency range:
Antenna input:
Standing wave ratio voltage:
input SHF-1 input SHF-2-1, SHF-2-2, SHF-2-3 Amplification ratio:
LPVA-1-8:
RA-8-26: no less 10 dB within the frequency range 8-12 GHz,
within the frequency range 12-18 GHz,
1...26 GHz.
coaxial with wave
impedance 50 Ohm
(connector M6 х 0,75).
no more 2,5;
no more 1,5.
MSHU-1-8:
MSHU-8-12:
MSHU-12-18:
no less 5 dB;
no less 19 dB
no less 22 dB within the
frequency range 18-26 GHz;
no less 32 dB;
no less 33 dB;
no less 27 dB.
Irregular amplification ratio:
no more 2 dB.
Loosening VCHK-1, VCHK-2:
within the frequency range 1-8 GHz
within the frequency range 8-12 GHz
within the frequency range 12-18 dB
no more 4 dB
no more 5 dB
no more 9 dB
Loosing of connecting UHF cable VCHK-3:
Polarization:
Level of antenna orthogonal polarization to level of main
no more 3 dB within the
frequency range 18-26 dB.
linear.
no more minus 20 dB.
52
polarization field within the working frequency range:
Turn of antenna polarization level:
± 90 degrees, with the
possibility to grade the
location with on the scale
with the scale factor 2
degrees.
SERIES MEASURE ANTENNAS
General:
The antennas is designed to meter sinus, noise and pulse electric
and magnetic fields for EMI/EMC and TEMPEST measures inside
laboratory, screened chambers and on open grounds and
represents itself a component of metering receivers, spectrum
analyzers, selective microvoltmeters of any kind. Guaranteed
accuracy of metering is provided by individual antenna’s calibration
performed according to Russia’s state standards requirements. The
series includes the following products.
Gain Figure (typical)
Specifications:
Model
Frequency range
active dipole
ACCORD 5-0
ACCORD 4-2
ACCORD 4-1
ACCORD 3-3/2
ACCORD 3-3
0.009 - 2000 MHz
0.05 - 1000 MHz
0.1 - 2000 kHz
2 - 1000 MHz
30 - 1000 MHz
53
ACCORD 3-2/2
active coil
CYCLONE 3-1
CYCLONE 3-2
0.009 - 30 MHz
0.2 - 1000 kHz
0.009 - 30 MHz
SERIES MEASURE PREAMPLIFIERS
SHU
General:
The units are designed as the producing low level noise
preliminary amplifiers for metering RF noises of small
intensity. Employment of this amplifiers in combination with
measuring receivers and various types spectra analyzers
allows to increase the signal-to-noise ratio and hence to
increase
their
sensitivity.
The series includes two models of preamplifiers: SHU-1,
SHU-2.
SHU-2 (typical)
Specifications:
SHU-1
Frequency range
0.009...2000 MHz
Gain ratio:
nominal value
frequency response unevenness
14...8 dB
not more than 3 dB
Noise ratio
not more than 6.5 dB
Peak output
- 20 dB
125 dB mV
Intercept point of 3-rd degree
136 dB mV
Stagnant wave ratio at input
(F = 30-2000 MHz)
not more than 1.6
Stagnant wave ratio at output
54
(F = 30-2000 MHz)
not more than 2.0
Input resistance
Power supply
Dimensions
Weight
SHU-2
Frequency range
50 Ohm
DC
100 x 60 x 20 mm
0.3 kg
0.009...1250 MHz
Gain ratio:
nominal value
frequency response unevenness
31 dB
not more than 4 dB
Noise ratio
not more than 3 dB
Peak output
- 20 dB
118 dB mV
Intercept point of 3-rd degree
130 dB mV
Stagnant wave ratio at input
(F = 30-2000 MHz)
not more than 2.0
Stagnant wave ratio at output
(F = 30-2000 MHz)
not more than 1.7
Input resistance
Power supply
Dimensions
Weight
50 Ohm
DC
100 x 60 x 20 mm
0.3 kg
U-SERIES
General:
This series of the preamplifiers are designed for signal
increase before receiver input with using the remote
aerials. This series are available in a dust & water proofed
cover. The feature of this preamplifiers is the extremely
low noise figure ratio and changeable gain ratio.
Product range
Model
L*
S*
C1*
C2*
Frequency range
1...2
GHz
2...4
GHz
4...6
GHz
6...8
GHz
Gain
20...40
dB
20...30
dB
15...32
dB
10...20
dB
Noise Figure not more than
3 dB
3 dB
4.5 dB
5 dB
Gain unevenness
+2 dB
+2 dB
+2.5 dB +2.5 dB
Power supply
(5+1)V
(5+1)V
(5+1)V
(5+1)V
Current consumption
(U=5V) not more than
50 mA
50 mA
50 mA
50 mA
In/output SWR not more
than
2
2
2
2
* IEEE STD-521-1976
55
U-series (typical)
SERIES MEASURE CURRENT PROBES
General:
The current probes are developed to measure RF noises
current inside power supply networks, communication,
control, interconnecting leads without electric circuits’
breaking. They operate in combination with metering
receivers, spectrum analyzers, selective microvoltmeters
providing an ingress resistance of 50 Ohm. The devices
operate principle is based on Rogovsky’s belt effect.
TI 2-3 (typical)
Specifications:
Model
TI 2-1
TI 2-2
TI 2-3
Frequency range
0.2 - 1000 kHz
0.09 - 30 MHz
0.009 - 300 MHz
56
Was this manual useful for you? yes no