GLV 865 AGC, GLV 865 F AGC
Amplifiers
Compact Line and Distribution Amplifier with Autom. Gain Control
GLV 865 AGC/865 F AGC
Compact line amplifier
for MATV/CATV distribution networks
i HF screw connectors (PG 11)
i Die-cast housing, protection type IP 65
i Equalization with internal jumpers, switchable to 606 MHz or 862 MHz
i Return channel (together with plug-in modules)
- Passive with diplex module
- Active with return channel module
i With diplex modules configurable return
channel and forward channel
- 5-30 MHz
- 47-862 MHz
- 5-65 MHz
- 85-862 MHz
Note
i GRM diplex and return channel modules are
behind the line / distribution amplifiers
Remotely supplied version GLV 865 F AGC
i Selectable remote feed route:
- Via input
- Via output
- Feed through
64
Type
GLV 865 AGC
GLV 865 F AGC
Order No.
944 786-002
944 799-002
Frequency range
Basic unit without RP modules
47 ... 862 MHz
47 ... 3862 MHz
Gain forward
G @ 862 MHz
Attenuator at input
28 dB
0 ... 20 dB
28 dB
0 ... 20 dB
47 ... 320 MHz
47 ... 320 MHz
95 ... 105 dBµV
±5 dB
95 ... 105 dBµV
±5 dB
Amplitude response forward
47...862 MHz
Line equalizer at input
Selectable equalizer pivot point
1.5 dB
0 ... 18 dB
862 / 606 MHz
1.5 dB
0 ... 18 dB
862 / 606 MHz
Random noise
Noise figure
7 dB
7 dB
Return loss
@ 40 MHz, -1,5 dB/octave
>14 dB
>14 dB
Output level forward
IMR2/ IMR3 ≥60 dB
CSO/CTB ≥60 dB, 42 ch, flat
117 / 124 dBµV
113 / 112 dBµV
117 / 124 dBµV
113 / 112 dBµV
RF connectors (75 O)
Input
Output
Test point input: bi-directional
Test point output: directional
PG 11
PG 11
-20 dB
-20 dB
PG 11
PG 11
-20 dB
-20 dB
Operating conditions
max. RF level (EMC)
Supply voltage
Max. throughpass current
Power consumption
Operating temperature
Protection class
Degree of protection (IP)
Weight
113 dBµV
195 ... 244 V
13 W
-40° ... +55°C
II
IP 65
2.0 kg
113 dBµV
32 ... 65 V
2A
14 W
-40° ... +55°C
II
IP 65
2.0 kg
Reference standards
Product standards
Safety
EMC
RoHS 2002/95/EG compliant
EN 50083-3 Class 2
EN 50083-1; EN 60065
EN 50083-2
yes
EN 50083-3 Class 2
EN 50083-1; EN 60065
EN 50083-2
yes
Packing unit
Sales unit
1 pc. in cardboard box
1 pc. in cardboard box
Automatic gain control (AGC)
Level controlled by the summarized output signals at frequency range
Adjustable output level range
AGC range