HARGON 261 Distribution amplifier, 1 active output, 1 GHz / 200 MHz RF PARAMETERS Forward Channel Bandwidth 85...260 - 1006 MHz Gain @1 GHz 1 x 39 ± 1 dB Noise figure 1 < 8 dB Flatness 2 ± 0.75 dB Slope ± 1 dB Output level 3: CTB ≤ - 60 dBc CSO ≤ - 60 dBc 112 dBμV 115 dBμV Return loss 4 > 18 dB Input testpoint (bi-directional) - 20 ± 1.5 dB Output testpoints (directional) - 20 ± 0.5 dB Forward gain (A), slope (E) control: A1, E1 A2, E2 0 - 20 step 0.5 dB 0 - 15 step 0.5 dB Reverse Channel Bandwidth 5 - 65...200 MHz Flatness 5 ± 0.5 dB Return loss 6 > 18 dB 1 GHz technology An extended bandwidth in downstream up to 1 GHz Gain 7 26 / - 8 dB HUM modulation 8 ≤ - 60 dBc Reverse gain (A), slope (E) control: A3, A4, A5, E3 0 - 20 step 0.5 dB Noise figure 9 < 6 dB 200 MHz technology A possibility of extending bandwidth in upstream up to 200 MHz HHT (Hand Held Terminal) support A quick and intuitive configuration of devices; the electronic documentation of the network OTHERS Voltage range: remote powering mains powering 30 - 65 V AC 230 ± 10% V AC Electronic adjustment Easy configuration by using buttons and LED Indicator Max. current for RF ports 7A Max. current for AC IN port 8A Power consumption < 13 W Operation temperature range - 40 - 60 ºC Connectors PG11 (others on request) Protection class IP 65 Dimensions (W x L x H) 202 x 172 x 80 mm Weight 2 kg VIG (VECTOR INGRESS GUARD) System compliant; Verification and elimination of the source of ingress in the network GREEN mode A significant reduction of power use thanks to optimization of its consumption AVAILABLE VERSIONS HARGON 261 089Y remote powering HARGON 261 089M mains powering A2 E2 0-15 dB 0-15 dB GREEN 2 GREEN 1 GREEN 0 LED DISPLAY Control buttons E1 0-20 dB A1 0-20 dB µP Controller BHHT E3 0-20 dB RBPL DF xxGA LREQ A4 0-20 dB A3 0-20 dB IS 1 0 / 6 / OFF LPBL DF xxGA SWITCH MODE POWER SUPPLY TP -20 dB TP -20 dB LTO / ATG 0 7A 7A 4A 7A LOCAL AC INPUT IN OUT 2 OUT 1 1. N.F. < 8 dB for f ≤ 1002 MHz, typical value 2. Valid 15 MHz after the starting frequency of the selected diplex filter 3. According to EN50083-3, 9 dB interstage slope, 42 channels CENELEC, value measured & guaranteed per each product 4. 18 dB for f ≤ 40 MHz, 18 dB -1.5 dB/oct for f > 40 MHz 5. For 6 - 60 MHz with DF65G; for 6 - 60 MHz with DF65G 6. > 16 dB for 5 MHz < f < 8 MHz; > 18 dB for f > 8 MHz 7. For active return path / passive return path; + / - 1 dB 8. For f > 16 MHz, remote current < 6 A @ 25 ºC, typical value 9. Up to 200 MHz, with diplex filters, typical value, NF < 7 for f = 200 MHz Unless otherwise specified, the whole specifications are tested with 65 / 85 diplex filters installed; GREEN = 0, at room temperature 25°C 21/03/2016 Specifications are subject to change without notice.
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertising