Point-of-Use Steam Fired Water Heater

Point-of-Use Steam Fired Water Heater
MODEL PS
Point-of-Use Steam Fired
Water Heater
65-119- Gallon Capacity
Features
■
Heavy Duty Construction
√
√
√
■
High Efficiency
√
√
■
Hydrastone cement lining provides long
tank life
Copper-silicon alloy tappings cannot rust
or corrode
High impact composite jacket cannot rust
or corrode and minimizes damage during
installation and transit
2" thick polyurethane foam insulation
reduces heat loss
Copper fin tube heating coil provides
highly efficient heat transfer
Packaged System
√
√
Steam operating controls are factory sized
and selected for efficient installation and
operation
Numerous options available for specialized
applications
Applications
■
■
■
■
■
Schools
Restaurants
Office Buildings
Hotels
Hospitals
■
■
Process Systems
Industrial Facilities
Model PS
NO
GLASS
LINING
Compact Steam Fired Water Heater
The Hubbell PS model is a point-of-use storage water heater
that utilizes steam to heat domestic water. Its compact
design takes up minimal floor space and eliminates the
need to rely on oversized instantaneous heaters or large
storage heaters for your low to medium demand hot water
requirements. The Hubbell PS model is constructed for
demanding commercial and industrial applications by utilizing a heavy duty storage vessel lined with specially
formulated Hydrastone cement and copper-silicon threaded
tank openings to ensure a long lasting and energy efficient
water heater. When you specify and install a Hubbell PS
model water heater, you will have confidence in knowing the
owner will be provided with a long lasting and trouble-free
source for hot water.
Use Steam To Heat Water At Point-Of-Use
Model PS
Water Heater Specifications
Tank:
Lining:
Capacities:
Orientation:
Connection Sizes
Inlet/Outlet:
Return Line:
Drain:
Relief Valve:
Relief Valve Type:
Pressure Rating (tank):
Coil Construction
Material:
Type:
Rating:
Tube:
Connections:
Carbon Steel
Hydrastone Cement
65 -119 gallons
Vertical
11/2" Male NPT
3
/4" Female NPT
3
/4" GHT
3
/4" Female NPT
T&P, 210oF, 150 psi
150 psi WP, 225 psi TP
Copper Fin Tube
Single Wall
150 psi WP, 300 psi TP
7
/8" O.D., 5/8" I.D.
3
/4" Male NPT
Max Input:
Temperature Regulator:
Temperature Range:
Main Trap Type:
Drip Trap Type:
Strainer Type:
199,900 BTU/HR
On/Off Steam Valve
100-170oF
F & T Cast Iron
Thermostatic
Y Cast Iron 20 Mesh
Screen
2" Polyurethane Foam
Insulation:
Warranty
Tank:
Coil:
Jacket:
3 year Non Pro-rated
1 year Non Pro-rated
High Impact Colorized
Composite
White and Black
Color:
NOTE:
Steam operating controls are factory selected and
supplied and shipped loose for in the field installation.
Steam controls include the following: steam control
valve, steam strainer, drip trap and main trap.
Optional Equipment
1. Double wall copper fin tube heating coil with leak
detection port. Connections are 1/2" MNPT.
6. Alternate temperature controller range,
please specify.
2. Combination water temperature and pressure
gauge installed in tank; 3" Dial, 30-240oF,
0-200 psi
7. Steam pressure reducing valve to limit the steam
supply to the control valve to
psi max.
3. Single solenoid safety system closes the steam
supply to the heating coil in the event of an over
temperature condition (requires 120V, 5 Amp)
8. Intra-tank circulating pump package to circulate
water within the tank to reduce stratification
4. Double solenoid safety system closes the steam
supply to the heating coil and opens the hot water
outlet to drain in the event of an over temperature
condition (requires 120V, 5 Amp)
9. Integrally welded seismic attachment points provide
side sway support
10. Factory piped controls
11. ASME tank construction
5. Electric back-up heating element in various
wattages and voltages (consult factory)
Please note: optional equipment may impact overall dimensions and weight. Please request submittal drawing from factory.
Steam Operating Controls Sizing
Steam
Pressure
Control
Valve
Steam
Strainer
Drip
Trap
Main
Trap
0 – 10 psi
1"
1"
1/2"
3/4"
11 - 25 psi
3/4"
3/4"
1/2"
3/4"
26 - 125 psi
1/2"
1/2"
1/2"
3/4"
Recovery Ratings & Heating Coil Selection
Wall
Type
SINGLE
DOUBLE
2 PSI
143
107
Gallons Per Hour (GPH) Heated at 100°F Δ T (40 - 140°F)
Steam Pressure (PSI)
5 PSI 10 PSI 15 PSI 20 PSI 25 PSI 30 PSI 40 PSI
157
171
189
203
217
227
241
118
128
142
152
163
170
181
Note: Maximum steam consumption is 211 Lbs/Hr for all of the above recoveries.
2
50 PSI 100 PSI
255
308
191
231
Top View
Outline Dimensions
Hot Water Outlet
Relief Valve
Combination
Return & Drain
Cold Water Inlet
40o o
45
45o
Hot Water Outlet
Protective Jacket
T&P Relief Valve
Tank Cross
Section
Hydrastone
/2 "
1
Steel
Pressure
Vessel
2" Foam
Insulation
Steam Inlet
Steam Strainer
Temperature
Sensing Bulb
Steam Heating
Coil
Cold Water Inlet
18"
Withdrawal
Space
Control Valve
Combination Return & Drain
Drip Trap
Condensate Trap
Condensate Outlet
Side View
Base
Model
Front View
Floor To: (Inches)
Storage
Overall
Overall
Capacity Diameter Height
Relief
Inlet
Outlet
Return
Coil
(Gallons) (Inches) (Inches)
Valve
PS65
PS80
PS100
PS120
65
80
100
119
26
26
26
28
54
64
76
76
14
14
14
14
Top
Top
Top
Top
15
15
15
15
Model Number Designation
PS
SL
—
46
57
68
68
Shipping
Weight
(lbs.)
16
16
16
17
395
470
485
555
Complete this section only when specifying
a back-up electric heating element.
—
■ Step 1
■ Step 2
■ Step 3
■ Step 4
■ Step 5
Model:
PS
Storage
Capacity:
65 -119
Gallons
Tank Type:
SL=Cement
Lined
Wall Type:
S = Single Wall
D = Double Wall
KW Selection: Voltage / Phase / Hz:
Steam
Supply
1.5 - 20 KW
A = 120-1-60
Pressure:
RS = 208-1-60
0 - 125 psi
■ Step 6
Example: PS120SL-S15
Is a point-of-use steam fired water heater with a 119 gallon cement
lined steel storage vessel. Heating coil is rated to heat 189 GPH from
40-140oF when supplied with 15 psi steam to the control valve. No
electric back up heat provided.
optioNNote
Any and all optional equipment for a water heater must be called out
in the written specifications. A model number in and of itself does not
reflect any optional equipment selected.
■ Step 7
R
S
T
W
T3
T7
T5
T4
T6
= 208-3-60
= 240-1-60
= 240-3-60
= 277-1-60
= 380-3-50/60
= 415-3-50/60
= 440-3-60
= 480-3-60
= 600-3-60
3
Master Specification: Model PS
Job Name
engineer
Representative
contractor
GENERAL
Provide a quantity of point-of-use steam fired water heater(s) Model No.
as manufactured by Hubbell of Stratford, CT. The unit shall be vertically mounted and suitably insulated, jacketed and provided
with the proper steam operating controls.
PRESSURE VESSEL
The tank shall be all welded steel commercial construction designed for 150 psi working pressure and contain
gallons of storage. The tank is to be lined with seamless Hydrastone cement to a minimum thickness of
1/2" on 100% of all interior tank surfaces and does not require any type of anodic protection. The tank shall be designed and
fabricated with copper-silicon threaded fittings and non-ferrous inlet and outlet piping for maximum corrosion resistance. The
cold water inlet shall be 11/2" Male NPT, the hot water outlet shall be 11/2" Male NPT, the recirculation line shall be 3/4" Female
NPT, and the drain shall be a 3/4" hose connection. A separate 3/4" Female NPT outlet is provided for relief valve installation.
The entire tank is to be insulated with a minimum of 2" thick polyurethane foam insulation. The complete heater shall be
supplied with a high impact colorized composite jacket which cannot rust or corrode and does not require painting. The vessel
shall be protected by an approved ASME rated automatic reseating combination temperature and pressure safety relief valve.
RECOVERY
The immersion copper fin tube single wall ( Optional Specification: Double wall ) heating coil shall be designed for a
maximum allowable steam pressure of 125 psi.
GPH from
The coil shall be rated to heat the control valve.
oF to oF when supplied with psi steam to
STEAM CONTROLS
All steam operating controls shall be factory supplied and shipped loose for in the field installation.
( Optional Specification: All steam controls shall be factory piped and assembled )
The following items are supplied by the factory:
(1) (1/2", 3/4", 1") Self Contained Temperature Control Valve (Steam Regulator)
(1) (1/2", 3/4", 1") Steam Y Strainer
(1) 1/2" Drip Trap, thermostatic type
(1) 3/4" Main Trap, F&T type
In addition, the following optional equipment may be included:
temperature and pressure gauge shall be factory installed in the tank; 3" Dial,
Option Dial water
30-240oF, 0-200 psi / 0-115oC, 0-1400 kPa
psi to psi.
Option Steam pressure reducing valve to reduce the steam pressure from
Option A single solenoid safety system shall be factory supplied to close the steam supply to the heating coil in
an over-temperature condition. (120 volt, 5 amp required).
Option
A double solenoid safety system shall be factory supplied to close the steam supply to the heating coil
as well as open a solenoid valve to send over-heated water to drain. (120 volt, 5 amp required).
Option
The unit shall be factory supplied with an immersion electric heating element rated at
KW
Volts Phase electrical power. The electric control panel shall
when supplied with include a thermostat, safety hi-temperature cut out device, and other required electrical components,
and shall be factory assembled, wired and tested.
WARRANTY
The heater manufacturer shall warranty all components against defects in workmanship and material for a period
of one (1) year from date of start-up and the pressure vessel for a period of three (3) years from date of start-up, provided
that the unit(s) are started within three (3) months of date of shipment and installed and operated within the scope of the tank
design and operating capability. Each heater shall be shipped with a complete set of installation and operating instructions
including spare parts list and approved drawings.
ISO 9001:2008
ISO
Made in the U.S.A.
Committed to continuous improvement...
Continuing research results in product improvement; therefore specifications are subject to
change without notice. For the most updated information, consult the factory directly.
The Electric Heater Company
■ P.O.
Box 288 ■ Stratford, CT 06615-0288 ■ Phone: 203-378-2659
info@hubbellheaters.com ■ www.hubbellheaters.com
■
Fax: 203-378-3593
[Rev B]