Syncro Product Overview Analogue Addressable Fire Control Panels 6 or 8 Loops Available with 6 or 8 detection circuits, each capable of hosting up to 126 devices (Apollo), 240 devices (Argus Vega) or 127 devices (Hochiki). Syncro uses the most advanced microprocessor technology to provide a control system of extremely high integrity. Syncro can be configured to suit all types of system, from the most simple, to the highly complex. Its fully integrated and secure network provides comprehensive scalability. A large area graphic display ensures that information is presented in plain language with detailed extra help available by pressing a ‘help’ button. Features 6 or 8 loop versions as standard 96 zone indicators Fully supports Apollo, Argus Vega & Hochiki protocols (Also backward-compatible with Series 90 detectors) Syncro supports three of the most widely used communication protocols produced by leading fire detector manufacturers and employs daily calibration routines to ensure that the system is always at optimum performance. Config. Features Comprehensive day/night mode facility Programmable one touch test mode Network up to 32 6 or 8 loop panels Powerful and versatile cause & effect programming 8 programmable sounder circuits as standard Cause & effect wizard including: 2 x 4 amp PSU’s to EN54 part 4 Cause & effect action Disablement configuration Large graphic display In built help and alarm information screens Complies with EN54-2/4 R Test mode configuration Real time clock Supports Apollo, Argus Vega and Hochiki loop powered sounders and beacons Stylish enclosure design Soft-touch tactile buttons 2 programmable function buttons 3 programmable front panel mounted LED’s Thermal printer (optional) Up to 1024 programmable inputs/outputs per panel via 2 wire RS485 serial link (optional) Simple Windows® graphical configuration utility Wide choice of languages available Model No. EN#63966S4P ООО "Фаст Инжиниринг" 125222, Россия, г.Москва, ул.Барышиха, д.14, корп.3 Тел./Факс: +7 (495) 794-75-04, +7 (499) 504-81-02 Page 10 www.fastgroup.ru E-mail: fast@fastgroup.ru Panels Product Code EN#63966S4 ENS#63966S4 EN#63968S4 ENS#63968S4 Specifications Loops Enable Zones Size (mm) Control No Yes No Yes 6 6 8 8 96 96 96 96 500W x 650H x 137D 500W x 650H x 137D 500W x 650H x 137D 500W x 650H x 137D ‘#’ - replace with ‘A’ for Apollo protocol, ‘V’ for Argus Vega protocol or ‘H’ for Hochiki protocol. For fitted printer add ‘P’ after stock code. Technical Finish Colour - lid & box Colour - controls plate & labels Detection circuits (Loops) Zone LED’s Display 8 sounder circuits - 2 x Fire contact 2 x Alarm contact 2 x Fault contact 2 x Programmable relay 1 2 x Programmable relay 2 2 x Fire routing output - 2 x Fault routing output - 2 x Extinguisher output - 2 x Fault input 2 x Reset input 2 x Intermittent input 2 x Continuous input 2 x Silence input 2 x Programmable input 1 2 x Programmable input 2 2 x Programmable input 3 2 x Auxiliary 24V DC output 2 x System fuse 2 x Mains fuse Operating Temperature Operating humidity Mains voltage supply Battery (24 hour standby) Day/night modes Input delays Output delays 2 programmable function buttons 3 programmable indicators Network Printer (option) Download lead - Epoxy powder coated BS 00 A 05 grey - fine texture RAL 7047 light grey - satin 6 or 8 (400mA each) 96 (up to 500 software zones) 8 lines of 40 characters graphic LCD Each fused at 1 Amp (total load 2 Amp per bank of 4 circuits) Volt free 1 Amp 30V DC Volt free 1 Amp 30V DC Volt free 1 Amp 30V DC Volt free 1 Amp 30V DC Volt free 1 Amp 30V DC Monitored-voltage reversing, fused at 500mA Monitored-voltage reversing, fused at 500mA Monitored-voltage reversing, fused at 1A Volt free contact input signals fault Volt free contact input resets panel Volt free contact input pulses sounder outputs Volt free contact input for continuous sounders Volt free contact input silences sounders Volt free contact for any action required Volt free contact for any action required Volt free contact for any action required Fused at 500mA 5 Amp self-resetting polyfuse 20mm 3 Amp -5 to +50 deg. C To 95% (non-condensing) 110 or 230V AC 50 or 60 Hz. (specify when ordering, default is 230V) 12Ah 12V (4 per panel) (non-networked) 2 with variable device sensitivity Individual for each device selectable up to 2 minutes Individual 2-stage to 10 minutes per stage Programmable to carry out any cause & effect, disablement or test action Red/yellow/green to indicate any action Up to 32 6 or 8 loop panels on 2 wires 40 column thermal S187 (standard) or X187LS (economy) Options Product Code Description K552# K232SYN Loop extension card (loops 7 & 8) Thermal printer kit (for retrofitting to non-printer models) 16 channel input/output board 8 way relay extender board 6 way sounder extender board 4 way conventional detection zone board Modem module (PSTN) K560 K547 K546 K545 K556P ‘#’ - replace with ‘A’ for Apollo protocol, ‘V’ for Argus Vega protocol or ‘H’ for Hochiki protocol. The manufacturer reserves the right to amend specifications without prior notice ООО "Фаст Инжиниринг" 125222, Россия, г.Москва, ул.Барышиха, д.14, корп.3 Тел./Факс: +7 (495) 794-75-04, +7 (499) 504-81-02 www.fastgroup.ru E-mail: fast@fastgroup.ru
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertising