FM/FMR Mini-indicator User Manual
EXCELL PRECISION CO,,LTD.
FM/FMR
Mini-indicator
User Manual
© Excell Precision CO.,LTD. 2015. All rights reserved Worldwide.
The information contained herein is the property of Excell Precision CO.,LTD. and is
supplied without liability for errors or omissions. No part may be reproduced or used
except as authorised by contract or other written permission. The copyright and the
foregoing restriction on reproduction and use extend to all media in which the
information may be embodied.
EXCELL PRECISION CO,,LTD.
TABLE OF CONTENTS
SAFETY PRECAUTION............................................................................................................... 2
CHAPTER 1 KEYPAD INSTRUCTION ........................................................................................ 3
CHAPTER 2 SPECIFICATIONS .................................................................................................. 4
CHAPTER 3 FRONT AND REAR PANELS.................................................................................. 5
3-1 FRONT PANEL ..................................................................................................................... 5
3-2 REAR PANEL ....................................................................................................................... 6
CHAPTER 4 INSTALLATION ....................................................................................................... 7
4-1 LOAD CELL ......................................................................................................................... 7
4-2 DIMENSIONS ....................................................................................................................... 8
4-3 BATTERY ASSEMBLAGE ........................................................................................................ 9
CHAPTER 5 EXTERNAL FUNCTION PARAMETER SETTING ................................................ 10
5-1
EXTERNAL FUNCTION SETTING ............................................................. 11
5-2
RS-232 SETTING ............................................................................... 14
CHAPTER 6 INTERNAL CALIBRATION.................................................................................... 20
6-1
SPECIFICATION CALIBRATION ............................................................... 21
6-2
WEIGHT CALIBRATION .......................................................................... 24
6-3
INTERNAL FUNCTION SETTING .............................................................. 26
6-4 ERROR MESSAGES ........................................................................................................... 28
CHAPTER 7 SPECIAL FUNCTION ........................................................................................... 29
7-1 ANIMAL SCALE SETTING .................................................................................................... 29
7-2 DUAL RANGE RESOLUTION SWITCH FUNCTION .................................................................... 30
7-3 PRE-TARE FUNCTION ........................................................................................................ 31
7-4 RESOLUTION SWITCH FUNCTION ........................................................................................ 31
7-5 MAINTAIN BEEPER VALUE SETTING ..................................................................................... 32
CHAPTER 8 INTERFACE.......................................................................................................... 33
CHAPTER 9 MAINTENANCE.................................................................................................... 35
9-1 RESTORE DEFAULT SETTING FOR ALL PARAMETERS (GENERAL CERTIFICATION)....................... 35
9-2 RESTORE DEFAULT SETTING FOR ALL PARAMETERS (OIML CERTIFICATION) ............................ 35
9-3 RESTORE DEFAULT SETTING FOR ALL PARAMETERS (BRIZAL CERTIFICATION) .......................... 35
9-4 RESTORE DEFAULT SETTING FOR ALL PARAMETERS (USA CERTIFICATION) ............................. 35
9-5 RESTORE DEFAULT SETTING FOR GENERAL FUNCTION PARAMETERS ...................................... 36
9-6 SELF-TEST MODE................................................................................................................ 36
9-6-1 Program Version Number........................................................................................ 37
9-6-2 7-Segment Display Testing ..................................................................................... 37
9-6-3 Keypad & Calibration Switch Testing....................................................................... 37
9-6-4 A/D Conversion Value ............................................................................................. 37
9-6-5 EEPROM Testing .................................................................................................... 37
9-6-6 RTC Time & Date Testing........................................................................................ 37
9-6-7 RS-232 Serial Output Interface Testing ( OP - 01 ) ................................................. 37
APPENDIX 7-SEGMENT DISPLAY CHARACTERS.................................................................. 38
04008076
1
ZSME300000206
EXCELL PRECISION CO,,LTD.
Before using the product
Thanks for your purchase of this indicator. In
order to operate it smoothly, extend its durability
and reduce the chance of breakdown, please
read this user manual carefully.
Safety Precaution
Swithch off the indicator before installation or dismantlement.
Keep the indicator away from the direct sun light. The operation temperature
is between 0 °C ~ +40 °C.
The ground connection of this indicator is necessary and this ground
impedance is less than 100 Ω.
Do not connect the ground with other equipments which need huge power
consumption.
Non-ground or incorrect connection might cause an electric shock or a
product breakdown.
Please wait more than one minute before re-power on.
Please operate or charge the indicator in an open area. Do not squeeze the
power cord to avoid wire on fire.
04008076
2
ZSME300000206
EXCELL PRECISION CO,,LTD.
Chapter 1 Keypad Instruction
Function
General Function
Setting
Operation
Press and hold
Description
Refer to <Chapter 5> External
Function Parameter setting for
details.
ENTER
Then press
Weighing
Parameter
Setting
Setting for decimal point, capacity,
Adjust calibration switch
division, zero tracking, and
to ON
unstable detection, etc. refer to 6-1
Specification Setting for details.
Calibration
Adjust calibration switch Refer to 6-2 Weight Calibration for
to ON
details.
Self-test Mode
During the countdown of
power on, press and
hold
Restore Default
Setting for All
Parameters
Restore Default
Setting for
General Function
Parameters
Refer to 9-4 Self-test Mode for
details.
ZER O
Adjust calibration switch
to ON, and then press
Refer to 9-1 for details.
ENTER
and hold
During the countdown of
power on, press and
Refer to 9-3 for details.
ENTER
hold
During the operation, use the following keys to complete all works.
ZER O
⇒ Increase the flash value by one
TA RE
⇒ Decrease the flash value by one
G RO SS
NET
⇒ Move the cursor leftward
04008076
F2
ENTER
ESC
3
⇒ Move the cursor rightward
⇒ Save setting
⇒ Abort setting / Exit
ZSME300000206
EXCELL PRECISION CO,,LTD.
Chapter 2 Specifications
Analog Specification
♦ Load Cell Current
♦ Max. Load Cell Input Voltage
♦ Input Sensitivity
♦ Conversion Rate
♦ Resolution
:DC 5 V ±5% 60 mA (up to four 350 Ω Load Cell)
:16 mV
: 0.15 μV/d or more
:Approximately 120times/s (max.)
: 20 bits
Digital Specification
♦
♦
♦
♦
♦
♦
Display
Display Frequency
Display Range
Min. Division
Decimal Point
Memory
:LCD, 6 digits, 25.4 × 10 mm (W × H), LED backlight
:50 times/s
:- 999999 ~ 999999
:1, 2, 5, 10, 20, 50
: 0, 0.0, 0.00, 0.000, 0.0000
:Calibration parameters and function settings are all
stored in EEPROM.
Optional Interface Card
♦
OP-01 RS-232 / RS-485(Includes RTC function)
Power Requirement
♦
Adaptor Spec
:input 120 / 230 V AC 50~60 Hz
Output 9 V / 1000 mA
♦ Optional 2 types of batteries : 6 V NiMH rechargeable battery kit (5 pcs)(1800
mA/hr)or general batteries (5pcs)
♦ Max. Power Consumption
:110 mA (with 4 Load Cell + backlight + RS-232
interface)
NiMH battery → 15 hours
General battery → 24 hours
45 mA (with 1 Load Cell + no backlight + no RS-232
interface)
NiMH battery → 36 hours
General battery → 60 hours
Please charge the Ni-MH battery at least 12~14 hours for first use.
Others
♦ Operation Temperature
:0 ~ 40°C
:< 85% RH
♦ Operation Humidity
♦ Dimension (mm)(W × D × H) :193 × 134 × 49.5
♦ Weight
:700 g
04008076
4
ZSME300000206
EXCELL PRECISION CO,,LTD.
Chapter 3 Front and Rear Panels
3-1 Front Panel
Indication:
:
Battery is charged (only available for rechargeable model)
: Battery is charging (only available for rechargeable model)
: tare mode
TARE
¾
The light is default on. When using
MOTION : unstable weighing
CFN-05 Animal Scale Mode or
M+
: accumulation mode
FNC-07 Maintain Beeper Value, it
GROSS : gross weight
works as HOLD LED light. When
opening dual-range resolution, it works
PT
: pre-tare
as RANGE1 LED light.
RANGE1/HOLD : dual-range resolution
¾
CFN-05 Animal Scale Mode and
FNC-07 Maintain Beeper Value can’t
indication (1)
be run at the same time.
RANGE2
: dual-range resolution
indication (2)
Keypad:
ESC
ZERO
TARE
G R O SS
NET
F2
1) Power ON / OFF, press and hold this key for 3 seconds to shut down.
2) Abort or exit when setting.
1) Weight backs to zero.
2) Increase the flash value by one when setting.
1) Eliminate the gross weight.
2) Decrease the flash value by one when setting.
1) Switch Gross / Net weight shown on display.
2) Move the cursor leftward when setting.
1) Keypad function (FNC-02 & FNC-03).
2) Move the cursor rightward when setting.
Keypad function (FNC-02 & FNC-03).
ENTER
04008076
Confirm key.
5
ZSME300000206
EXCELL PRECISION CO,,LTD.
3-2 Rear Panel
1
2
5
3
4
1. Battery Case
2. RS-232 / RS-485 input / output
3. DC 9 V power input
4. calibration switch
5. load cell connect socket
04008076
6
ZSME300000206
EXCELL PRECISION CO,,LTD.
Chapter 4 Installation
4-1 Load Cell
4
5
9
3
8
2
7
1
6
感應器連接綫
Load
cell cable
感應器
Load
cell
EXC+
SEN+
SIG+
SIG-
EXCSEN-
隔離綫
Shield
4-wire(5-wired)Load Cell
Pin 1 connects with SIG+
Pin 2,3 short to connect with EXCPin 4,5 short to connect with EXC+
Pin 6,7,8 connect with shield
Pin 9 connects with SIG-
04008076
6-wire(7-wired)Load Cell
Pin 1 connects with SIG+
Pin 2 connects with SENPin 3 connects with EXCPin 4 connects with SEN+
Pin 5 connects with EXC+
Pin 6,7,8 connects with shield
Pin 9 connects with SIG-
7
ZSME300000206
EXCELL PRECISION CO,,LTD.
4-2 Dimensions
04008076
8
ZSME300000206
EXCELL PRECISION CO,,LTD.
4-3 Battery Assemblage
將多餘的電線塞入電池孔中
Stuff the
surplus wires into the battery case.
04008076
9
ZSME300000206
EXCELL PRECISION CO,,LTD.
Chapter 5 External Function Parameter
Setting
ENTER
Under general weighing conditions, press
, and the screen will show:
ENTER
Press
ZERO
Press
TARE
key
key
ENTER
Press ESC to escape.
Back to weighing condition.
⇒ External function setting
⇒ RS-232 / RS-485 interface function
04008076
10
ZSME300000206
EXCELL PRECISION CO,,LTD.
5-1
External Function Setting
Press
ENTER
*Parameter Code
⇒ Key Disable
Select the desired
parameter code.
⇒ DSP Update(Display Update)
⇒ F1-key Setting
⇒ F2-key Setting
Press
⇒ ENTER+F2 Setting
ENTER
⇒ Backlight Function Setting
⇒ Beeper Setting
The screen shows
previous parameter
setting. Enter the
desired parameter
setting. Press ENTER
Press
ESC
⇒ Maintain Beeper Value
⇒ Auto-power Off
to escape the setting.
ZERO
⇒ Increase the flash value by one
TA R E
⇒ Decrease the flash value by one
GROSS
NET
⇒ Move the cursor leftward
F2
ENTER
ES
04008076
11
⇒ Move the cursor rightward
⇒ Save setting
⇒ Abort setting or exit
ZSME300000206
EXCELL PRECISION CO,,LTD.
External Function Parameter Setting
Parameter
Code
FNC-00
Function
Key disable
FNC-01
DSP
Update
FNC-02
F1-key
Setting
FNC-03
FNC-04
F2-key
Setting
ENTER+F2
Setting
Parameter
0000
↓
1111
0
1
2
3
4
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0
Setting Value
Description
0000 is corresponding to:
ON
(from left to right)
Default
Setting
0*000
1 OFF
No limit
20 times/s
10 times/s
5 times/s
1 times/s
Print (printing)
Units (units switch)
M+ (accumulation and printing)
MC (memory clearing)
Weight / Times Accumulation / Weight
Accumulation Display Switch
HR (high resolution switch)
Pre-Tare (Pre-tare function)
Format for Brazil
Print (printing)
Units (units switch)
M+ (accumulation and printing)
MC (memory clearing)
Weight / Times Accumulation / Weight
Accumulation Display Switch
HR (high resolution switch)
Pre-Tare (Pre-tare function)
Format for Brazil
Print (printing)
Units (units switch)
M+ (accumulation and printing)
MC (memory clearing)
Weight / Times Accumulation / Weight
Accumulation Display Switch
HR (high resolution switch)
Pre-Tare (Pre-tare function)
Format for Brazil
1
5
1
0
The symbol “*” is standard for OIML Certification in context.
04008076
12
ZSME300000206
EXCELL PRECISION CO,,LTD.
Parameter
Code
Function
FNC-05
Backlight Setting
FNC-06
Beeper Setting
FNC-07
Maintain Beeper
Value
FNC-08
Auto-power Off
(Minutes)
Setting Value
Description
Parameter
Default
Setting
0
Auto backlight on
(backlight on in operation lnly)
1
2
0
Backlight on (backlight always on)
Backlight off
Beeper off
1
Beeper on
0
1
2
0
No function
Mode 1
Mode 2
No function
1
0
It works when the weight is stable
and non-key is pressed in weighing
mode.
1~60
1
0
FNC-02& FNC-03& FNC-04= 7 Format for Brazil
F R " W T 2 1 L C D "
?
0
0
0
1
0
P
04008076
,
0 0
9 / 1 2 / 1 1
0 : 4 3 : 0 9
0 0 0 0 0 0 0 0 0 0
1 , 1
,
0 0 0 9 1 2 1 1 1 0 4 3 0 9
13
ZSME300000206
EXCELL PRECISION CO,,LTD.
5-2
RS-232 Setting
Press
*Parameter Code
ENTER
⇒ information pattern
⇒ transmission method
⇒ transmission rate
Selet the desired
Parameter code with
⇒ parity, bit length, stop bit
⇒ unstable or over load
⇒ auto transmission condition
Press
ENTER
⇒ command address
⇒ output format
⇒ transmission times
The screen shows previous
parameter setting. Enter the
desired parameter setting.
Press
⇒ date setting
⇒ time setting
ENTER
Press
ESC
to escape the setting.
ZERO
⇒ Increase the flash value by one
TA R E
⇒ Decrease the flash value by one
GROSS
NET
⇒ Move the cursor leftward
F2
ENTER
ES
04008076
14
⇒ Move the cursor rightward
⇒ Save setting
⇒ Abort setting or exit
ZSME300000206
EXCELL PRECISION CO,,LTD.
OP-01 RS-232 / RS-485 Interface Function
Parameter
Code
Function
RS1-00
Information
Pattern
RS1-01
Transmissio
n Method
RS1-02
Transmissio
n Rate
Parameter
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
0
1
2
3
0
RS1-03
Parity,
bit length,
stop bit
1
2
RS1-04
RS1-05
RS1-06
04008076
Unstable or
Over Load
Auto
Transmissio
n
Condition
Command
Address
0
1
0
Setting Value
Description
Display Correspindingly
Gross Weight
Net Weight
Tare
Weight Accumulation Value
Times Accumulation Value
Output with Date & Time
PT Output with Date & Time
Format 1 for Brazil
Format 2 for Brazil
Continuous transmission
Auto transmission
Default
Setting
or
for
Press
transmission
Command Mode (no address)
Command Mode (with address)
1 200
2 400
4 800
9 600
No Parity
8 Bits Length
N,8,1
1 stop bit
Odd Parity
O,7,1
7 Bits Length
1 stop bit
Even Parity
7 Bits Length
E,7,1
1 stop bit
Continuous Output
Stop Output
Positive (over + 10d)
0
1
Positive / Negative
(over + 10d, under – 10d)
00
↓
99
Available only if RS1-01 setting is
“4”
15
0
3
0
0
0
0
ZSME300000206
EXCELL PRECISION CO,,LTD.
Parameter
Code
RS1-07
RS1-08
Setting Value
Description
Standard Format
UMC 600
No Limit
1 times/s
2 times/s
5 times/s
10 times/s
20 times/s
Year-Month-Day
(RS232 optional)
Time-Minute-Second
(RS232 optional)
Function
Parameter
0*
Output format
1
0
1
2
Transmission
times
3
4
5
RS1-09
Date Setting
XX.XX.XX
RS1-10
Time Setting
XX.XX.XX
Default
Setting
0
4
XX.XX.
XX
XX.XX.
XX
The symbol “*” is standard for OIML Certification in context.
Remark:
This is general certification option when the parameter is set for “0~5” in RS1-00 and the
data is transmitted to printer.
This is general certification option when the parameter is set for “6” in RS1-00 and the
parameter is set for “6” in FNC-02 (or the parameter is set for “6” in FNC-03).
This is general certification option when the parameter is set for “0” in RS1-04 and the
parameter is set for “6” in RS1-00.
Transmission Format
RS1-00 ⇒ 0 ~ 3
S
T
Header 1
, G
S
,
Header 2
+
1
2
3
4
.
5
Weight Data ( 8 digits )
6
g CR LF
Unit
Terminators
Header 1
ST : Stable Weight / US : Unstable Weight / OL : Weight Overload
Header 2
GS : Gross Weight / NT : Net Weight / TR : Tare
Weight Data ( 8 digits )
The first digit of weight data indicates “+ / -” value of weight. The other 7 digits,
including decimal point, indicate the weight value. If the weight is over load (Header 1:
OL), the screen only shows “+ / -” and decimal point.
Unit
kg, lb, t or ” blank.”
Note: lb is only available for non-approval model.
Terminators
CR and LF are data termination code.
04008076
16
ZSME300000206
EXCELL PRECISION CO,,LTD.
RS1-00 = 4
T
,
N
1
2
3
CR
LF
3
4
RS1-00 = 5
T
,
W
+
1
2
.
5
6
k
g
CR
LF
RS1-00 = 6
D
A
T
E
:
2
0
X
X
/
X
X
/
T
I
M
E
:
X
X
:
X
X
:
X
X CR LF
G
R
O
S
:
+
1
2
3
4
.
5
6
k
g CR LF
N
E
T
:
+
1
2
3
4
.
5
6
k
g CR LF
T
A
R
:
+
1
2
3
4
.
5
6
k
g CR LF
T
N
:
X
X
X CR LF
T
W
:
+
1
2
3
4
.
5
6
k
g CR LF
X
X CR LF
S
E
X
X CR LF
RS1-00 = 7
D
A
T
E
:
2
0
X
X
/
X
X
/
T
I
M
E
:
X
X
:
X
X
:
X
X CR LF
G
R
O
S
:
+
1
2
3
4
.
5
6
k
g CR LF
N
E
T
:
+
1
2
3
4
.
5
6
k
g CR LF
T
A
R
:
+
1
2
3
4
.
5
6
k
g CR LF
P
T
+
1
2
3
4
.
5
6
K
g CR LF
T
N
:
X
X
X CR LF
T
W
:
+
1
2
.
5
6
k
g CR LF
04008076
E
S
3
4
17
ZSME300000206
EXCELL PRECISION CO,,LTD.
RS1-00 = 8 format 1 for Brazil
S , G G G . G G G , T T T . T T T , N N N . N N N <CR> <LF>
RS1-00 = 9 format 2 for Brazil
D
H
B
L
T
N
T
A
O
R
I
A
P
A
T
R
U
Q
R
A
:
A
:
T O
:
U I D O :
A
:
:
:
D
H
+
+
+
TN
TW
D
H
G
N
T
TN
TW
/
:
G
N
T
TN
TW
M
H
G
N
T
CR
TW
M
H
G
N
T
LF
TW
/
:
.
.
.
Y
H
G
N
T
Y
H
G
N
T
CR
k
k
k
. TW TW k
CR LF
LF
g
CR LF
g
CR LF
g
CR LF
g
CR LF
RS1-07 = 4 Zebro format for Brazil
F R " W T 2 1 L C D "
?
1 0 0 0
4 5 0
5 5 0
1
0
0
P
9 / 1 0 / 1 0
9 : 4 6 : 3 9
0 0 0 5 5 0 0 0 0 0 4 5 0 1 9 1 0 1 0 0 9 4 6 3 9
1 , 1
Note : Notes as followed in the brackets will not be output.
1000 (GROSS)
450 (PRE-TARE)
550 (NET)
19/10/10(day / month / year)
09:46:39( time: minute: second)
RS1-07 = 5 WWW format for Brazil
= W W W . W W W W
Note:“W”means weight.
04008076
18
ZSME300000206
EXCELL PRECISION CO,,LTD.
Command Mode
Command
Function
Command
Function
READ / RW
Weight Reading
CT
Tare Clearing
ZERO / MZ
Weight Re-zeroing
Rl
Weight Accumulation
TARE / MT
Gross Weight Deducting
Rm
Times Accumulation
NTGS
Gross / Net Switch
Rn
Date
MG
Gross Weight Indicating
Ro
Time
MN
Net Weight Indicating
AT
DT
Weight and Times
Accumulation
Weight and Times
Accumulation Clearing
n After setting above commands, it must add the termination code “CR( 0DH ) and
LF( 0AH )”
o If the command is not correct, it shows “E” + “Command Unidentified”.
p If the command mode is chosen with address (RS1-01 = 4), add “ @ address” in front of
each command.
Example: When RS1-06 = 1, for reading weight value, the whole complete command
should be “@01RW(CR)(LF)”
04008076
19
ZSME300000206
EXCELL PRECISION CO,,LTD.
Chapter 6 Internal Calibration
Adjust calibration switch to “ON”, and the screen displays:
After 2 seconds
ENTER
Press
Press
TARE
ZERO
ENTER
Press
ZERO
Press
TAR E
ENTER
Adjust calibration switch back to“OFF”
⇒ Specification Calibration
⇒ Weight Calibration
⇒ Internal Function Setting
ZERO
⇒ Increase the flash value by one
TA R E
⇒ Decrease the flash value by one
GROSS
NET
⇒ Move the cursor leftward
F2
ENTER
ES
04008076
20
⇒ Move the cursor rightward
⇒ Save setting
⇒ Abort setting or exit
ZSME300000206
EXCELL PRECISION CO,,LTD.
6-1
Specification Calibration
*Parameter Code
Press
ENTER
⇒ Decimal Point
⇒ Maximum Weighing Capacity
⇒ Division 1
Select the desired
Parameter code with
⇒ Division 2
⇒ Zero Tracking Setting
⇒ Unstable Detection Setting
Press
ENTER
The screen shows previous
parameter setting. Enter the
desired parameter setting.
Press ENTER
Press
ESC
to escape the setting
ZERO
⇒ Increase the flash value by one
TA R E
⇒ Decrease the flash value by one
GROSS
NET
⇒ Move the cursor leftward
F2
ENTER
ES
04008076
21
⇒ Move the cursor rightward
⇒ Save setting
⇒ Abort setting or exit
ZSME300000206
EXCELL PRECISION CO,,LTD.
Specification Parameter Description
Parameter
Function
Code
Parameter
CSP-00
Decimal
Point
CSP-01
Maximum
Weighing
capacity
Division1
CSP-02
Setting Value
Description
Default
Setting
Refer to sescriptions in next page.
0
999999
↓
000000
Max. value for weight display
999999
1
2
5
10
20
50
Min. value for weight display
1
Min. value for weight display
1
1
2
CSP-03
Division 2
5
10
20
50
CSP-04
Zero
Tracking
Setting
Refer to sescriptions in next page.
0.25d
CSP-05
Unstable
Detection
Setting
Refer to sescriptions in next page.
0.25d
04008076
22
ZSME300000206
EXCELL PRECISION CO,,LTD.
Parameter Display Description
CSP-00
Decimal Point
Display
Decimal Point Digit
None
CSP-04
.
1 digit
.
2 digit
.
3 digit
.
4 digit
Zero Tracking Setting
Display
Division / Time
.
0.25 d / 1 s*
.
0.5 d / 1 s*
0.75 d / 1 s
.
1d/1s
1.25 d / 2 s
.
.
1.5 d / 2 s
1.75 d / 2 s
.
2d/2s
No Zero Tracking
CSP-05
Unstable Detection Setting
Display
Division / Time
.
0.25 d / 1 s*
.
0.5 d / 1 s*
0.75 d / 1 s
.
1d/1s
1.25 d / 2 s
.
.
.
1.5 d / 2 s
1.75 d / 2 s
2d/2s
No Unstable Detection
The symbol “*” is standard for OIML Certification in context.
04008076
23
ZSME300000206
EXCELL PRECISION CO,,LTD.
6-2
Weight Calibration
Turn on and warm up the machine for 15 to 30 minutes before calibration.
adjust the calibration switch to“ON” , and the screen will show
Press
TAR E
or
ZERO
to select
Procedure
ENTER
ENTER
Zero
Calibration
Zero calibration completed
ESC
Place
weights
and set
the
weight.
ENTER
Weight
Calibration
ESC
ENTER
Confirmed
Set calibration
switch to ”OFF”
Zero Calibration
a ) Ensure nothing on the platter. After the scale being stable, press
ENTER
and the screen
will display “ - - - - - - - ” . The zero calibration will be complete after 5 seconds.
b ) To abort zero calibration, just press
ESC
.
Weight Calibration
a ) Place an object which weight is known on the platter. Input the weight value and wait
the scale to be stable, then press
ENTER
. The screen will show “ - - - - - - - ”. The
weight calibration will be complete after 5 sconds.
b ) To abort weight calibration, just press
04008076
ESC
24
.
ZSME300000206
EXCELL PRECISION CO,,LTD.
Password Setting
Adjust calibration
switch to“ON”
After 2 seconds
ZERO
Input new password
“0000” means no password.
ENTER
Confirm new password
(input again)
ENTER
After complete password setting, when entering calibration mode or function setting mode,
the screen shows
for 1 scond, and then
It’s necessary to input the correct password to continue each setting.
If the input password is incorrect, the screen shows
04008076
25
.
ZSME300000206
EXCELL PRECISION CO,,LTD.
6-3
Internal Function Setting
Press
ENTER
*Parameter Code
⇒ Tare or Zero Function under
Unstable Status
⇒ Zero when Scale Turned on
Select the desired
Parameter code with
⇒ Back to Zero Range
⇒ Filter Sampling Rate
⇒ Filter Strength
Press
ENTER
⇒ Animal Scale Mode
⇒ Animal Scale Stable Range
⇒ Animal Scale Sampling Frequency
The screen shows
Previous parameter
Setting. Enter the
Desired parameter
setting.
Press ENTER
⇒ Dual Range Resolution Setting
⇒ Midpoint Setting for Dual Range
Resolution
⇒ Gravity Calibration
⇒ Operation of Accumulative Value/ Times
upon Unstable Condition
Press
04008076
ESC
to escape the setting
26
ZSME300000206
EXCELL PRECISION CO,,LTD.
Internal Function Parameter Description
Parameter
Code
Function
CFN-00
Tare or Zero
Function under
Parameter
Setting Value
Description
Default
Setting
0
ON
Unstable Status
1*
OFF
CFN-01
Zero when Scale
Turned on
0
OFF
1
ON
CFN-02
Back to zero
range
0% ~ 30%
CFN-03
Filter Sampling
0~9
The larger number setting, the
lower speed rate is.
6
CFN-04
Filter Strength
0~5
The larger number setting, the
stronger filter is.
2
0
OFF
value%
(The parameter is less
than or equal to 2.)*
1
2
Mode 1: The weight value won’t
be shown if the weighing
condition is unstable.
Mode 2: The weight value
shows in stable or unstable
weighing condition.
0
Animal Scale Mode for Brazil
Mode 2: Stable Range Setting
0 ~ 100% (The parameter is less than or
equal to 10.)*
0
8 times
10
1
CFN-05
0%:Full range re-zero
1% ~ 30%: Capacity setting
1
Animal Scale
Mode
2
3
CFN-06
Animal Scale
Stable Range
CFN-07
Animal Scale
Sampling
Frequency
1
2
3
4
16 times
32 times
64 times
128 times
CFN-08
Dual Range
Resolution Setting
0
Multi-interval
1
Multi-range
CFN-09
Midpoint Setting
for Dual Range
Resolution
0 ~999999
CFN-10
Gravity Calibration
9.78032
|
9.83218
CFN-11
Operation of
Accumulative
Value/Times upon
Unstable Condition
Set the demarcation point
for dual range resolution.
2
0
5 000
Gravity calibration for the
different using & production zone. 9.79423
0
ON
1*
OFF
1
The symbol “*” is standard for OIML Certification in context.
04008076
27
ZSME300000206
EXCELL PRECISION CO,,LTD.
6-4 Error Messages
(1)
Load Cell or A/D circuit is abnormal.
(2)
Real weighing value is lower than or equal to zero value.
(3)
Internal resolution is lower than 0.15 μV/d range.
(4)
Incorrect password.
(5)
Internal value is lower than zero range.
(6)
Internal value is higher than zero range.
04008076
28
ZSME300000206
EXCELL PRECISION CO,,LTD.
Chapter 7 Special Function
7-1 Animal Scale Setting
2 CFN-05 = 1 (Animal Scale Mode1:The weight value won’t be shown if
the weighing condition is unstable.)
When there is nothing on the platter, the screen will show:
When an object is on the platter, take a 20-gram object for example, the screen will
show:
.
The weight value will be kept on the display if the weight is lower than 10d or you can
push “Enter” key to reset weighing process, then the screen will show:
2 CFN-05 = 2 (Animal Scale Mode 2: The weight value shows on the
display under the stable or unstable weighing condition.)
When the weight value reaches the range of CFN-06 and CFN-07 setting, the screen
will keep showing the weight value.
When the weight value is over the range of CFN-06 and CFN-07 setting, the screen will
show the normal weight measurement.
For example: CFN-06=30
CFN-07=2
WT
重量
Weight Holding
重量保持
30d
取消重量保持
Cancellation of Weight Holding
32 次
10d
04008076
T
時間
29
ZSME300000206
EXCELL PRECISION CO,,LTD.
7-2 Dual Range Resolution Switch Function
The dual range resolution will be available when the parameter settings of CSP-02 and
CSP-03 are different.
2 CFN-08 = 0
Multi-interval
If CFN-09 = 5 000
WT
重量
最小刻度
Division 2
2
5 000
1
T
時間
0
最小刻度
Division 1
2 CFN-08 = 1
Multi-range
If CFN-09 = 5 000
WT
重量
2
2
5 000
2
0
T
時間
1
Recover
when back to zero
回到零點才恢復
04008076
30
ZSME300000206
EXCELL PRECISION CO,,LTD.
7-3 Pre-Tare Function
2
FNC-02 or FNC-03 setting is at parameter 6 (Pre-Tare Function )
Under weight display status, press
thescreen will show:
F2
or
key (according to FNC setting),
Input the desired
Pre-tare value
Press
ENTER
Back to weight display status(PT indication lights up)
Pre-tare Cancellation
When the gross weight column shows “0”, press
TAR E
key to cancel the pre-tare value.
7-4 Resolution Switch Function
2 FNC-02 or FNC-03 setting si at parameter 5.
Under weight display status, press
or
F2
key (according to FNC
setting),the display will show 10 times of the original division value and it will
return back to the original one after 5 seconds.
04008076
31
ZSME300000206
EXCELL PRECISION CO,,LTD.
7-5 Maintain Beeper Value Setting
Mode 1
RS-232 transmission mode enters into HOLD value transmission mode automatically. When the
weight is higher than 10d, the indicator holds the max value of weight. Press ENTER key to
unlock HOLD mode.
RS-232 transmits one data of PEAK of HOLD value when press ENTER .
Display
Enter key
Mode 2
RS-232 transmission mode enters into HOLD value transmission mode automatically. When the
weight is higher than 10d, the indicator holds the max value of weight. When the weight is lower
than 10d, the indicator unlocks HOLD value automatically and shows the weight value which is
lower than 10d.
RS-232 transmits one data of PEAK of HOLD value. The data point is from PEAK HOLD value
to lower than 10d.
Display
04008076
32
ZSME300000206
EXCELL PRECISION CO,,LTD.
Chapter 8 Interface
OP-01 RS-232 / RS-485 Serial Output with RTC(Real Time Clock)
CN2
CN3
123
123
Short 1 and 2 pins to get RS-485 output.
Short 2 and 3 pins to get RS-232 output.
Pin Allocation of Rear Panel
4
5
9
8
1
2
3
7
Pin
Function
2
3
TXD
RXD
SG
DA
DB
5
6
7
6
RS-485 interface is capable to connect up to 10 mini-indicators.
04008076
33
ZSME300000206
EXCELL PRECISION CO,,LTD.
Connection Description (RS-485)
終極電阻
Terminal
Resistant
電腦主機
Host
EX0419 # 1
RS - 06 = 01
EX0419 # 2
RS - 06 = 02
EX0419 # 10
RS - 06 = 10
Notice
♦
If the termainal resistant is built-in the host interface, it’s not neceffary to connect with
another one from outside.
♦
04008076
If the host computer is no signal ground (SG), it’s not necessary to connect with it.
34
ZSME300000206
EXCELL PRECISION CO,,LTD.
Chapter 9 Maintenance
9-1 Restore Default Setting for All Parameters (General
Certification)
(1) Adjust the calibration switch to “ON”during the countdown of power on,
ENTER
press
and hold them simultaneously.
(2) The screen will show
(3) To confirm, press
.
ENTER
and hold until showing
, and then adjust the
calibration switch to “OFF”.。
9-2 Restore Default Setting for All Parameters (OIML Certification)
(1) Adjust the calibration switch to “ON”during the countdown of power on,
press
F2
ENTER
and hold them simultaneously.
(2) The screen will show
(3) To confirm, press
.
ENTER
and hold until showing
, and then adjust the
calibration switch to “OFF”.
9-3 Restore Default Setting for All Parameters (Brizal Certification)
(1) Adjust the calibration switch to “ON”during the countdown of power on,
press
G R O SS
N ET
and hold them simultaneously.
ENTER
(2) The screen will show
(3) To confirm, press
.
ENTER
and hold until showing
, and then adjust the
calibration switch to “OFF”.
9-4 Restore Default Setting for All Parameters (USA Certification)
(1) Adjust the calibration switch to “ON”during the countdown of power on,
press
TARE
and hold them simultaneously.
ENTER
(2) The screen will show
(3) To confirm, press
ENTER
.
and hold until showing
, and then adjust the
calibration switch to “OFF”.
04008076
35
ZSME300000206
EXCELL PRECISION CO,,LTD.
9-5 Restore Default Setting for General Function Parameters
ENTER
(1) Press
and hold simultaneously during the countdown of power on.
(2) The screen will show
(3) To confirm, press
.
ENTER
and hold until re-turning on.
9-6 Self-test Mode
(1) Press
ZERO
and hold it during the countdown of power on.
(2) The screen will show
(3) Use
ZERO
Press
Item
ENTER
or
TAR E
, which means entered self-test mode.
keys to select test program.
key to enter self-test, and press
Display
key to exit.
Testing Item
Program Version Number Displaying
1
7-Segment Display Testing
2
04008076
ESC
3
Keypad and Calibration Switch Testing
4
A/D Conversion Value Displaying
5
EEPROM Testing
6
RTC Date & Time Testing
7
OP-1 RS-232 Serial Output Interface
Testing
36
ZSME300000206
EXCELL PRECISION CO,,LTD.
9-6-1 Program Version Number
7-Segment display shows program version number XXXXXX.
Press
ENTER
again to show 1:
General certification
2:
OIML certification
3:
Brazil certification
4: USA certification
9-6-2 7-Segment Display Testing
7-Segment display shows
to
and “.”.
9-6-3 Keypad & Calibration Switch Testing
Adjust calibration switch to “ON”, and press any key, the corresponding bit will be
changed from
to .
9-6-4 A/D Conversion Value
7-Segment display shows the internal value of the scale.
9-6-5 EEPROM Testing
Showing
represents in normal condition.
Showing
represents in abnormal condition.
9-6-6 RTC Time & Date Testing
Press
ENTER
key to enter the testing mode, and the screen will show date YY.MM.DD.
For example: “05.11.03” represents 3rd of November, 2005.
Press
ENTER
key again to show time HH.MM.SS.
For example: “09.45.50” represents 9 o’clock, 45minutes and 50 seconds.
9-6-7 RS-232 Serial Output Interface Testing ( OP - 01 )
(1) Short Pin2 and Pin3 of the 9-pin D-SUB socket of serial output.
Showing
represents in normal condition.
Showing
represents in abnormal condition.
(2) If connected with a computer (protocol must be corresponding), the screen will
show
04008076
to
, which means RS-232 output is in normal condition.
37
ZSME300000206
EXCELL PRECISION CO,,LTD.
Appendix 7-Segment Display Characters
Number
04008076
Display
Letter
Display
Letter
0
A
N
1
B
O
2
C
P
3
D
Q
4
E
R
5
F
S
6
G
T
7
H
U
8
I
V
9
J
W
K
X
L
Y
M
Z
38
Display
ZSME300000206
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement