02 | Keysight | FieldFox Handheld Analyzers – Technical Overview
Carry Precision with You
Measuring up and earning a spot in your field kit is the driving idea behind Keysight’s
FieldFox handheld analyzers. They’re equipped to handle routine maintenance, in-depth
troubleshooting and anything in between. Better yet, FieldFox delivers precise microwave and millimeter-wave measurements — wherever you need to go.
Why choose FieldFox?
–– Measure with confidence — precise measurements agree with benchtop results
–– Withstands your toughest working environments — rugged enough to meet MIL-specs
–– Weighs less than alternative solutions — 7.1 lb (3.2 kg)
–– Offers budget flexibility — choose capabilities you need today and easily upgrade later
RF and microwave
(combination) analyzers
Microwave vector
network analyzers
Microwave spectrum
analyzers
Base: Cable and antenna analyzer
Base: Transmission/reflection
vector network analyzer (VNA)
Base: Spectrum analyzer
Key options:
–– Spectrum analyzer
–– Vector network analyzer
–– Built-in power meter
–– Pulse measurement
–– Channel scanner
–– Real-time spectrum analyzer
(RTSA)
Key options:
–– Built-in power meter
–– Pulse measurement
Key options:
–– Built-in power meter
–– Pulse measurements
–– Channel scanner
–– Real-time spectrum analyzer
(RTSA)
03 | Keysight | FieldFox Handheld Analyzers – Technical Overview
Leverage our Legacy of Measurement Leadership
With FieldFox, you’re carrying the
precision of our industry-standard
benchtop analyzers. By delivering levels
of consistency not available in any other
handhelds, FieldFox ensures confidence in
your results.
FieldFox industry innovations
Inside, we leveraged well-tested algorithms from Keysight’s high-performance
VNAs. To lighten your load, we simplified
calibration by adding built-in standards
and eliminating the need to carry calibration kits.
Vector network analyzer
Dynamic range up to 100 dB
2012
FieldFox handheld microwave
analyzer
2008
FieldFox handheld RF analyzer
2009
PXA X-Series signal analyzer
2007
PNA-X vector network analyzer
2001
PSA spectrum analyzer
2000
PNA vector network analyzer
1984
8510A vector network analyzer
1978
HP 8566B spectrum analyzer
First 50 GHz handheld microwave analyzer
Cable and antenna analyzer
DTF and TDR in a single sweep
Spectrum analyzer
Absolute amplitude accuracy ± 0.5 dB
To enhance spectrum analysis, FieldFox
includes the same PowerSuite measurements used in Keysight signal analyzers,
enabling fast, accurate, one-button
characterization of channelized communication systems. The InstAlign capability
lets you instantly make accurate power
measurements in the field, even when
temperature fluctuates.
2015
ieldFox 50 GHz handheld F
microwave analyzer
“FieldFox’s result is almost identical to my PNA.
I want one of these for all of my engineers.”
– Senior calibration engineer from spacecraft research and development center.
04 | Keysight | FieldFox Handheld Analyzers – Technical Overview
Increase System Uptime and Reduce Mission Risk
Install and maintain cellular systems with the cable and antenna
(CAT) tester
–– Ensure communication continuity with all the essential measurements needed to
troubleshoot and maintain microwave links
–– Always be at the ready with an instrument display easily optimized for clear viewing
in direct sunlight or darkness
–– Reduce measurement complexity and time-to-repair with quick and accurate line
sweeps in the field without calibration kits
–– Protect your investment by adding software license key upgrades as your needs
change
Photo courtesy of INTELSAT
–– Increase your team’s preparedness in the harshest environments with a completely
sealed instrument rugged enough to meet MIL specs
Work better and faster in radar installation and maintenance (I&M)
–– Improve your team’s efficiency with a single analyzer that provides network, spectrum,
and power measurements up through the Ka and Q bands
–– Ensure your team’s readiness with an instrument rugged enough to meet
MIL-PRF-28800F Class 2 and IP53 specs
–– Increase system uptime and reduce mission risk with fast and accurate characterization of cables, waveguides, and components
–– Reduce your cost of ownership, with only one instrument to purchase and maintain
Photo courtesy of INTELSAT
–– Increase your confidence with system and component measurements that agree
with trusted Keysight/Agilent/HP benchtop instruments
Accelerate I&M work at satellite ground stations
–– Validate system performance with fast, detailed analysis of up uplink and downlink
signals
–– Quickly diagnose faults using built-in cable and antenna analysis, network analysis,
and power measurements
–– Perform accurate frequency translation gain/loss measurements to verify upconverters and downconverters at the LRU level
–– Depend on MIL-spec ruggedness and a completely sealed instrument, designed to
withstand harsh environments
Learn more about FieldFox applications and download resources at:
www.keysight.com/find/fieldtest
Photo courtesy of INDRA S.A.
–– Maintain cable, waveguide, and antenna systems consistently and efficiently with
calibrated VNA and CAT measurements
05 | Keysight | FieldFox Handheld Analyzers – Technical Overview
Enhance Research and Education
Add the ultimate companion tool to every R&D bench
–– Equip your lab with must-have measurements up to 50 GHz with the affordable
FieldFox
–– Increase your confidence with measurements that agree with trusted Keysight/
Agilent/HP benchtop instruments
–– Get unprecedented flexibility with the multi-function FieldFox
–– Give your team measurement convenience with a portable form factor and battery
operation
–– Free up high-performance benchtop instruments with FieldFox
Bring a new dimension to engineering classes and labs
–– Optimize EE/ECE department budgets with as many as 10 instruments in one
–– Buy what you need today, and add features via software license keys as your
curriculum changes
–– Achieve maximum teaching efficiency with a portable instrument that is easy to
carry from class to lab and provides battery life of 3.5 hours
–– Enhance student comprehension by remotely projecting, monitoring, and controlling
the instrument
–– Reinforce theoretical concepts by easily demonstrating measured results
–– Save time developing your curriculum with complimentary ready-made lesson plans
Learn more about FieldFox applications and download resources at:
www.keysight.com/find/fieldtest
06 | Keysight | FieldFox Handheld Analyzers – Technical Overview
Pick Up FieldFox for its Ergonomics
Portrait design and
large buttons for easy
operation – even
with gloves on
Convenient side
strap makes it easy
to hold and carry
Anti-glare 6.5 inch
LCD display with
LED backlight
11.5”
(292 mm)
Backlit keypad
Task-driven keys
are grouped to
easily perform field
measurements
Dedicated marker
keys for quick marker
function access
7.4”
(188 mm)
07 | Keysight | FieldFox Handheld Analyzers – Technical Overview
… and Depend on Its Durability and Convenience
TOP
Type-N (f)
Port 1
3.5 mm (m)
2.4 mm (m)
Port 2
Connector bay protects
RF connectors
Get precise location using
the built-in GPS receiver
External reference and
external trigger input
Quick connect
shoulder strap clips
RIGHT SIDE
LAN port for data transfer
and SCPI programming
SD flash card for
data storage
Keep going with
field-swappable
batteries that last
up to 3.5 hours
External reference and
external trigger output
Gasketed doors protect
ports from moisture
LEFT SIDE
Built-in DC supply
for powering external
bias-tees, probes, and
active devices
USB ports for easy
data storage and
SCPI programming
08 | Keysight | FieldFox Handheld Analyzers – Technical Overview
Utilize the Industry’s Most Comprehensive Handheld Analyzers
Cable and antenna analyzer
–– Distance-to-fault (DTF) and return loss/VSWR
–– 1-port cable loss, 2-port insertion loss, and time-domain reflectometry (TDR)
–– Integrated QuickCal up to 18 GHz for simple field measurements—
no calibration kit required
Spectrum analyzer
–– Unprecedented amplitude accuracy of ± 0.5 dB with InstAlign 1—no warm-up
required
–– Tracking generator, independent source, and preamplifier covering the full
frequency range
–– Channel power (CHP), occupied bandwidth (OBW), interference analysis,
analog demodulation
Vector network analyzer
–– All four S-parameters, magnitude and phase
–– Time-domain analysis, mixed-mode reflection S-parameters
–– CalReady, QuickCal, full 2-port cal, TRL, waveguide cal, ECal support,
and a Guided Calibration Wizard
Real-time spectrum analyzer (RTSA)
–– Capture signals as short as 12 µs with 100% POI with a maximum 10 MHz
real-time bandwidth and full amplitude accuracy
–– Visualize small signals as short as 22 ns independent of amplitude accuracy
–– Detect a low level signal in the presence of a high power transmitter using the
spectrum density view
09 | Keysight | FieldFox Handheld Analyzers – Technical Overview
Utilize the Industry’s Most Comprehensive Handheld Analyzers (continued)
Built-in power meter
–– Power measurements over a defined bandwidth, without an external sensor
–– Easy to view analog and digital displays
–– ± 0.5 dB accuracy with InstAlign1
Power measurements using a USB power sensor
–– Accurate absolute power measurements at a CW frequency
–– Swept-frequency power measurements
–– Frequency-offset capability for converter test
Pulse measurements using a USB peak power sensor
–– Peak power, average power and peak-to-average ratio measurements
–– Pulse profile characterization
–– Portable solution for radar pulse analysis
Vector voltmeter
–– Cable trimming, phase shift, and electrical length measurements
–– A/B and B/A ratio measurements
–– Similar functionality to the HP 8508A VVM
1. With FieldFox InstAlign, internal amplitude alignments occur automatically as enviromental
conditions change, without any user intervention.
10 | Keysight | FieldFox Handheld Analyzers – Technical Overview
Utilize the Industry’s Most Comprehensive Handheld Analyzers (continued)
Extended range transmission analysis (ERTA)
–– Scalar insertion loss measurement of in-situ cables with long distances
between test ports
–– InstAlign enables accurate microwave measurements with no warm-up
–– Converter test using ERTA’s frequency-offset capability
Channel scanner
–– Channel power measurements up to 20 channels
–– Customizable frequency and bandwidth settings for each channel
–– Data logging capability with geo tagging
11 | Keysight | FieldFox Handheld Analyzers – Technical Overview
Choose the FieldFox that Meets Your Needs
1
Notes:
For more information on N9912A, see FieldFox N9912A RF Analyzer, Technical Overview (5989-8618EN)
For more information on N9923A, see FieldFox N9923A Vector Network Analyzer, Technical Overview (5990-5087EN)
1. Combination analyzer = Cable and antenna tester (CAT) + Vector network analyzer (VNA) + Spectrum analyzer (SA)
12 | Keysight | FieldFox Handheld Analyzers – Technical Overview
Create the Right Configuration for Your Application
Select the capabilities you need today and add more as needs change: features are field-upgradeable and are added via software
licence keys. RF and microwave analyzers are referred to as combination analyzers in this section.
Feature
Combination analyzers
Vector network analyzers
Spectrum analyzers
N9912A
N9913/4/5/6/7/8A
N9950/1/2A
N9923A
N9925/6/7/8A
N9935/6/7/8A
N9960/1/2A
Cable and antenna analyzer
ü
ü
ü
ü
VSWR and reflection
VNA transmission/reflection
ü
ü
ü
ü
–
VNA full 2-port S-parameters
–
ü
ü
ü
–
1-port mixed-mode S-parameters
–
ü
ü
ü
–
VNA time domain
ü
ü
ü
ü
–
QuickCal
ü
ü
ü
ü
–
CAT/ vector network analysis
TDR cable measurements
Vector voltmeter
1
–
ü
–
ü
–
1 port
ü
ü
ü
–
Spectrum analysis
Spectrum analyzer
ü
ü
–
–
ü
Extended range transmission analysis (ERTA)
–
ü
–
–
ü
Tracking generator
ü
ü
–
–
ü
Pre-amplifier
ü
ü
–
–
ü
Interference analyzer and spectrogram
ü
ü
–
–
ü
Spectrum analyzer time gating
–
ü
–
–
ü
Channel scanner
ü
ü
–
–
ü
Analog demodulation
–
ü
–
–
ü
Real-time spectrum analyzer (RTSA)
–
ü
–
–
ü3
ü
ü
ü
ü
ü
3
Power measurements
USB power sensor meas. versus frequency
USB power sensor support
ü
ü
ü
ü
ü
Pulse meas. with USB peak power sensor
ü
ü
ü
ü
ü
Built-in power meter
ü
ü
–
ü
ü
System features
Remote control capability
GPS receiver
DC bias variable-voltage source
SCPI over LAN and USB
2
ü
ü
ü
ü
ü
external
ü
external
ü
ü
–
ü
–
ü
ü
ü
ü
ü
ü
ü
Notes:
Some of the features listed here require an option. See page 22 for option information or see the FieldFox Handheld Analyzer Configuration Guide for complete
information on all FieldFox products and accessories http://literature.cdn.keysight.com/litweb/pdf/5990-9836EN.pdf
1. QuickCal is not available on N995xA analyzers.
2. SCPI over USB for the N991x/2x/3x models is only available for serial number prefix starting with MY5607/SG5607/US5607 or upgraded with
Option N9910HU-xxx.
3. RTSA capability is only available for N995xA/6xA and N991xA/3xA with serial number prefix starting with MY5607/SG5607/US5607 or upgraded with
Option N9910HU-100/200/300/400/500.
13 | Keysight | FieldFox Handheld Analyzers – Technical Overview
Cable and Antenna Analyzer
Fifty to sixty percent of microwave-link
equipment issues are related to cables,
antennas and connectors. Degraded
feeder lines cause poor coverage, link
failures, and reduced sensitivity in the
receive path. To maintain the quality of a
microwave link, it is critical to keep cable
and antenna systems in good working
condition. FieldFox is uniquely qualified to
provide all the necessary measurements to
troubleshoot and maintain these systems.
Insertion loss and cable loss
Insertion loss or cable loss characterizes
the loss of a jumper cable, feeder cable,
diplexer, or gain of a tower-mounted
amplifier (TMA). With FieldFox, you can
measure both the 1-port cable loss and
2-port insertion loss. Also, FieldFox’s ERTA
option, described on page 16, is useful for
measuring long, lossy in-situ cables.
Return loss/VSWR
Return loss (RL) or VSWR is the
single most important parameter used to
measure and verify a cable and antenna
system. This measurement reflects the
power transfer efficiency of a given
system.
Distance-to-fault (DTF) and
time-domain reflectometry (TDR)
DTF helps you determine the location
of discontinuities in feeder lines. TDR
helps you determine the nature of the
discontinuities, for example, short, open,
or water ingress.
With FieldFox, you can make RL and
DTF measurements at the same time.
This helps you correlate overall system
degradation with specific faults in the
cable and antenna system. The built-in
cable editor lets you edit existing cable
types onsite, and save them as new cable
types with user-defined names.
View return loss and DTF simultaneously
Measure both DTF and TDR in
single sweep
FieldFox’s TDR complements RL and DTF
measurements. TDR measures impedance
changes along the cable and helps identify
specific faults, RL exposes mismatch
issues, and DTF indicates faults and poor
connections. FieldFox is the only handheld
instrument that can measure both DTF
and TDR in a single sweep.
Characterize filter insertion loss
Gain insight into faults with TDR measurements
14 | Keysight | FieldFox Handheld Analyzers – Technical Overview
Cable and Antenna Analyzer (continued)
CalReady-calibrated at power
on and ready to go
Save time and get right to work with
FieldFox’s CalReady feature. With CalReady, the analyzer is already calibrated
and ready to make measurements such as
S11, S22, 1-port cable loss, and DTF/TDR
measurements without having to connect
and disconnect additional calibration
devices.
Hassle-free calibration in the
field with QuickCal
FieldFox comes with a built-in calibration
capability that allows you to calibrate
the network analyzer without carrying a
cal kit into the field. With any other test
instrument, when you add additional
devices to the test port, such as jumper
cables or adapters, you need to recalibrate
using a cal kit.
FieldFox’s QuickCal supports measurements such as insertion loss/gain, 1-port
cable loss, return loss, and DTF/TDR.
Note: N995xA does not support QuickCal.
Broadband calibration
FieldFox allows you to make broadband
calibrations, which means the instrument
is calibrated over the maximum frequency
range. After a broadband calibration,
you can change the frequency range or
number of points without recalibrating the
instrument. The calibration is interpolated,
and accuracy is maintained.
User cal kit support
Use FieldFox’s QuickCal capability and perform
calibrations without carrying a cal kit
For users who wish to use traditional
mechanical calibration kits, FieldFox
supports most Keysight/Agilent/HP
cal kits, and also allows you to define
your own custom calibration kits.
Fast and accurate calibration
with ECal
The FieldFox calibration engine supports
Keysight’s USB ECal modules. ECal
support reduces calibration time and the
need to make multiple connections during
testing, while also providing for greater
consistency between measurements. For
FieldFox users, that translates into fewer
human errors and increased accuracy.
Perform fast and accurate calibrations using ECal
15 | Keysight | FieldFox Handheld Analyzers – Technical Overview
Spectrum Analyzer
In microwave, radar, and satellite communications, and commercial microwave
backhaul, you may be responsible not only
for hardware installation and maintenance,
but also over-the-air signal quality.
You may also need to regularly monitor
unexpected signals and perform signal
surveillance.
FieldFox’s spectrum analyzer is
optimized to excel in a dynamic spectral
environment. You may face measurement
challenges such as the need to detect
a low-level signal under strong signal
conditions (requiring high dynamic range),
or close-in small interference signals
(requiring excellent phase noise).
FieldFox’s superior dynamic range
(TOI > +15 dBm), close in phase noise
(—111 dBc/Hz at 10 kHz offset), and fast
sweep time make these challenging tasks
easier. FieldFox’s spectrum analyzer also
provides a full power measurement suite
and complete trace and state control.
Unprecedented amplitude
accuracy without instrument
warm-up
With FieldFox’s InstAlign capability,
internal amplitude alignments occur
automatically as environmental conditions
change, without any user intervention.
This provides unprecedented amplitude
accuracy of ± 0.5 dB for spectrum analysis
and power measurements. Better yet,
FieldFox provides this accuracy
immediately upon instrument turn on—
no warm-up required.
Monitor frequency spectra up to 50 GHz with
FieldFox
Spectrum analyzer time gating
The testing of RF pulses is always
challenging because so many instrument
settings interact. With Option 238, gated
FFT with time gating, FieldFox behaves like
a spectrum analyzer and an oscilloscope.
This enables you to quickly detect pulses
in the time and frequency domains. A gate
time of 6 µs to 1.8 s enables simultaneous
examination of one or more pulses, or
pulse rise and fall times, revealing the
effects of spectrum growth due to various
pulse shapes. Functions such as video
trigger, external trigger and RF burst
ensure reliable pulse detection. Automatic
trigger-delay and bandwidth settings
enhance characterization of RF pulses.
Analyze pulsed RF signals using the time-gating
option
16 | Keysight | FieldFox Handheld Analyzers - Technical Overview
Real-time spectrum
analyzer (RTSA)
With the widespread increase of wireless
technologies in commercial and military
networks, the spectral environment is
filled with intentional and unintentional
interference.
The spectrum density view displays three
dimensional data on a two dimensional
display. It uses color to show the number
of times a frequency and amplitude point
is detected during a capture interval.
The interfering signals result in network
quality deterioration and communication-link breakdowns. Additionally, the
prevalent use of digital modulation and
burst-transmission methods have made
it difficult to reliably detect interference
sources.
This is an excellent way to understand and
visualize the spectral occupancy of the
frequency band. For example, with RTSA
you can detect a low-level signal in the
presence of a high power transmitter using
the spectrum density view.
This is where RTSA in FieldFox can help.
With the combination of a fast, overlapping FFT processing technique, gap-free
measurement, and a 10 MHz real-time
bandwidth, FieldFox is able to detect
signals as short as 12 µs with 100% POI
with full amplitude accuracy.
In some applications, detecting signals is
the critical factor, independent of amplitude accuracy. In such cases, FieldFox can
detect signals as short as 22 ns.
Density display with settable persistence
Finding an elusive signal can typically take
hours or days. With FieldFox’s recording
and playback, data can be saved for
further analysis offline at a later date.
With RTSA in FieldFox, you can now
eliminate the need for a separate,
dedicated instrument. When needed, just
shift to real-time capabilities in the same
unit with one key press.
Identify multiple types of signals in the same band
(Bluetooth and Wifi)
Multi-pulse detection with the density display
17 | Keysight | FieldFox Handheld Analyzers – Technical Overview
Spectrum Analyzer (continued)
Interference analyzer
Channel scanner
Interference can be internal or external,
uplink or downlink, and has a direct
impact on the quality of service (QoS)
of a communication network. FieldFox’s interference analyzer is designed to identify
interfering signals quickly. Spectrogram
and waterfall displays detect intermittent
signals or monitor signals over a period
of time. You can record signal traces into
internal memory or external flash memory
devices, and play back the saved traces
for offline processing. It has excellent
dynamic range.
Channel scanner allows users to make
multiple channel power measurements
simultaneously. It is used to verify
wireless network coverage, path loss
and potential interference issues. It also
can be used to measure primary carriers
and their intermodulated products. Each
instrument state can be a custom set of
frequencies with each frequency having a
unique integrating bandwidth. Users can
record and playback the data with data
logging. Using time interval logging along
with geotagging, files can be exported
to Google Earth for network coverage
analysis.
AM/FM analog demodulation
Using FieldFox’s analog demodulation,
users maintaining AM/FM radio transmitters can demodulate and characterize
AM and FM transmitters. They can tune
to the signal and listen to the audio tones
using FieldFox’s built-in speakers or a
headphone. They can also measure the
RF spectrum, the demodulated waveform
and AM/FM metrics such as carrier power,
modulation rate, and SINAD.
Waterfall display makes interference hunting easier
Characterize AM/FM signals using AM/FM demodulation
Scan up to 20 channel simultaneously with the
channel scanner option
18 | Keysight | FieldFox Handheld Analyzers - Technical Overview
Spectrum Analyzer (continued)
IF signal output
FieldFox provides a spectrum analyzer
IF output with 25 MHz bandwidth. This
enables use as a frequency downconverter
and digitize the signal using external test
equipment like real time scope, or VSA to
do deep signal analysis.
Field strength measurements
To characterize the electric and magnetic
fields, the gain and loss of the antenna
and cables must be accounted for. With
FieldFox, you can load antenna factors and
cable loss data using either the front panel
or the complimentary Data Link software.
Independent signal source
FieldFox has a built-in independent signal
source, with a frequency range of up to
50 GHz. The signal source can be tuned
to any frequency, independent of the
spectrum analyzer frequency. You can
use the signal source to create a test
signal to measure coverage, antenna
isolation, antenna direction alignment,
and shielding effectiveness, and to verify
frequency-offset devices.
Extended range transmission
analysis (ERTA)
Measuring long in-situ microwave cables
such as those on ships is a challenging
task, and requires instruments with high
dynamic range and fast measurement
speed. These measurements were traditionally done using benchtop scalar
analyzers, which are cumbersome to
operate in the field. Using FieldFox’s
ERTA, users can measure dynamic
ranges of 108 dB (at 6 GHz) or 77 dB
(at 26.5 GHz), with a portable analyzer
that requires no calibration and no
warm-up. ERTA uses two FieldFoxes,
one deployed at each end of the cable.
One FieldFox acts as a source, while
the other acts as a receiver. By taking
advantage of Keysight’s proprietary
InstAlign technique, this configuration
can be used to make cable loss measurements with accuracy of ± 0.7 dB.
Use the internal microwave signal source for
transponder testing
Measure long, lossy cables using ERTA
19 | Keysight | FieldFox Handheld Analyzers – Technical Overview
Vector Network Analyzer
FieldFox can be configured with VNA
transmission/reflection (T/R) capability
for S11 and S21 measurements, or with
full 2-port capability for measurements
of all four S-parameters and full 2-port
calibration.
With a full 2-port network analyzer, you
can measure the forward and reverse
characteristics of your component without
having to disconnect, turn around, and
reconnect it to the analyzer. Additionally,
the full 2-port calibration gives you the
best measurement accuracy possible.
Calibration
FieldFox’s guided Cal Wizard takes guessing out of calibration and allows you to
easily perform the following calibrations:
–– Full 2-port unknown thru
–– Full 2-port QSOLT
–– OSL, response, enhanced response
–– TRL, LRL, offset short
Simultaneously measure and view all four
S-parameters, with a single connection
FieldFox’s four independent, sensitive
receivers provide 94 dB of dynamic
range for measurement of high rejection,
narrowband devices such as cavity filters.
The receivers also enable full 2-port error
correction with the unknown thru method,
allowing users to measure non-insertable
devices accurately and easily.
FieldFox’s calibration engine is the same
engine that powers the well-respected
Keysight ENA and PNA network analyzers.
FieldFox leverages Keysight microwave
expertise to deliver consistent measurements with Keysight benchtop VNAs.
Use the marker bandwidth/Q factor function to
simplify filter testing and tuning
20 | Keysight | FieldFox Handheld Analyzers – Technical Overview
Vector Network Analyzer (continued)
Network analyzer time domain
Vector voltmeter
With the time-domain option, FieldFox
computes the inverse Fourier transform
of the frequency-domain data to display
reflection or transmission coefficients
versus time. Time-domain gating can be
used to remove unwanted responses such
as connector mismatch or cable discontinuities, and the results can be displayed
in either time or frequency domain.
Using FieldFox’s vector voltmeter (VVM),
you can measure the phase shift and
electrical length of a device. You can
view results on the large display as far as
ten feet or three meters away. VVM also
provides ratio measurements of magnitude
and phase of two channels, A/B or B/A.
You can use this capability to verify the
magnitude and phase differences between
multiple signal paths such as in an antenna
or phased array.
Waveguide support
Waveguides are widely used to provide
transmission links between microwave
transmitters and antennas, as waveguides
have less loss than coax. Keysight
offers both high-performance and also
economical waveguide calibration kits.
The economical kits are ideal for field
maintenance and troubleshooting because
they provide good measurement results at
a lower cost.
Easily use waveguides with FieldFox
FieldFox offers all the key functionalities
of the HP 8508A in a handheld form factor,
and without the need for the source,
bridge and accessories required with the
8508A.
Mixed-mode S-parameters
With FieldFox, you can measure the common- and differential-mode reflections of
a device. Mixed-mode S-parameters are
also known as balanced measurements.
This measurement requires the full 2-port
VNA and 2-port cal functionality.
Simplify cable trimming with the vector voltmeter
capability
Characterized common and differential mode reflections with mixed-mode S-parameter measurements
21 | Keysight | FieldFox Handheld Analyzers – Technical Overview
USB power measurements
USB power sensor support
Pulse measurements
FieldFox can connect with Keysight USB
power sensors to make RF and microwave
power measurements. Using USB peak
power sensors, you can measure both
the average and the peak power of a
modulated signal.
FieldFox’s pulse measurement option
allows you to efficiently characterize
pulsed RF signals such as those used in
radar and electronic warfare systems,
leveraging the Keysight USB peak power
sensors. Measurements include peak
power, peak to average ratio, and pulse
profile parameters such as rise time, fall
time and pulse repetition frequency.
USB power measurements
versus frequency
Simplify power measurements with USB power
sensors
In addition to power measurements at a
single CW frequency, you can measure
power versus frequency - a swept measurement. FieldFox’s source frequency
can be set equal to the sensor/receiver
frequency, or with an offset. The frequency
of both the source and receiver are swept,
and the two track each other. The offset
frequency can be negative, zero, or
positive.
This capability is useful for characterization of the scalar transmission response
of devices such as mixers and converters.
The FieldFox source stimulates the DUT
and the power sensor is used as the
measurement receiver.
Characterize mixers with FieldFox and a USB
power sensor
Use FieldFox to characterize pulses
22 | Keysight | FieldFox Handheld Analyzers – Technical Overview
Software and System Features
Remote control capability with
iPad and iPhone
Engineers and technicians can now
remotely monitor and control their
FieldFox using their iOS device such as
an iPhone, iPad, or iPod Touch. FieldFox’s
Remote Viewer iOS app emulates the
front panel of the unit, letting you simply
press any FieldFox key right from your
iOS device. The app also allows you to
instantly access technical documents
such as data sheets.
FieldFox’s Data Link software
makes report generation and
documentation easier
FieldFox’s complimentary Data Link
software provides data transfer, data
definition and report generation. You can
add markers and limit lines to traces,
and you can load cable files and antenna
factors using Data Link.
Remote control via LAN and
FieldFox programming
Built-in variable voltage DC bias
FieldFox has a built-in variable voltage
DC bias source. The DC bias source can
provide DC power to amplifiers under test
and bias tower mounted amplifiers (TMA)
when you need to sweep through the TMA
to reach the antenna (bias tees available
separately).
Built-in GPS
Control and view your FieldFox via your iPad
A built-in GPS receiver provides
geo-location tags to measurements.
The geo data—time, latitude, longitude,
and elevation—can be displayed and
saved in data files. In addition to location
information, the GPS provides an external
reference to improve FieldFox frequency
accuracy.
USB keyboard and mouse
support
Obtain geolocation data with the built-in GPS
capability
FieldFox supports use of USB keyboards
and mice to simplify the input of text such
as file names while working in the field.
All FieldFox models can be controlled
using SCPI over LAN and USB1.
Simplify text entry with a USB keyboard and mouse
1. SCPI over USB for the N991x/2x/3x models is only available for serial number prefix starting with
MY5607/SG5607/US5607 or upgraded with Option N9910HU-xxx.
23 | Keysight | FieldFox Handheld Analyzers – Technical Overview
Designed for You and the Work You Do Everyday
Carry FieldFox wherever you
need to go
Field-proof usability for better
answers in less time
–– Kit friendly at 6.6 lb (3.0 kg) for the
N991/2/3xA and 7.1 lb (3.2 kg) for the
N995/6xA
–– Bright, low-reflection display and
backlit keys enable easy viewing in
direct sunlight or darkness
–– Large buttons are easy to operate,
even when wearing gloves
–– Intuitive user interface is designed
for your workflow, enabling measurements in fewer key presses
–– Field swappable battery lasts up to
3.5 hours
–– Non-slip rubber grip securely fits in
your hands and won’t slide off the
hood of your vehicle
–– Vertical “portrait” orientation makes
it easy to hold and operate at the
same time
–– One-button measurements simplify
complex setups and ensure quick,
accurate results with confidence
–– Calibration Wizard guides user
to ensure simple and accurate
calibrations
–– Standard three-year warranty
ensures field confidence, especially
in harsh environments
Easily operate FieldFox, even when wearing
gloves, through the large front panel keys
–– 5, 7 and 10 year warranties are
also available
Read measurements in direct sunlight with
the transflective display
24 | Keysight | FieldFox Handheld Analyzers – Technical Overview
Designed for Your Toughest Working Conditions
Rugged enough to meet MIL-specs
–– Completely sealed instrument enclosure provides
measurement stability in harsh environments, -10 to +55 ºC
(14 to 131 ºF)
–– Specially designed to protect instrument from damage due
to drops, shock or other external impacts
–– Water-resistant chassis, keypad and case withstand wide
temperature ranges and salty, humid environments
–– Meets MIL-PRF-28800F Class 2 requirements
–– Type tested and meets MIL-STD-810G, Method 511.5,
Procedure I requirements for operation in explosive
environments
–– Type tested and meets IEC/EN 60529 requirements for
ingress protection
Count on extended instrument reliability with FieldFox’s dust-free design:
no vents or fans
25 | Keysight | FieldFox Handheld Analyzers – Technical Overview
Configuration in Brief
See the FieldFox Handheld Analyzer Configuration Guide for complete information on all FieldFox products and accessories
http://literature.cdn.keysight.com/litweb/pdf/5990-9836EN.pdf
RF and microwave analyzers are referred to as combination analyzers in this section.
Option
Description
Combination analyzers
Vector network analyzers
Spectrum analyzers
N991xA
N995xA
N992xA
N993xA
N996xA
ü
ü
-
ü on N991xA
not on N995xA
ü
–
CAT/network analysis
010
VNA time domain
112
QuickCal
210
VNA transmission/reflection
ü
Base model
–
211
VNA full 2-port S-parameters
ü
ü
–
212
1-port mixed-mode S-parameters
ü
ü
–
215
TDR cable measurements
ü
ü
–
Base model
ü
Note 1
ü
ü
–
Note 2
Note 2
ü
305
Cable and antenna analyzer
308
Vector voltmeter
320
Reflection meas. (RL, VSWR and scalar meas.)
Spectrum analyzer
209
Extended range transmission analysis (ERTA)
ü
–
ü
220
Tracking generator
Note 3
–
ü
233
Spectrum analyzer
ü
–
Base model
235
Pre-amplifier
ü
–
ü
236
Interference analyzer and spectrogram
ü
–
ü
238
Spectrum analyzer time gating
ü
-
ü
312
Channel scanner
ü
-
ü
350
Real-time spectrum analyzer (RTSA)
ü
-
ü
355
Analog demodulation
ü
-
ü
Power measurements
208
USB power sensor meas. versus frequency
ü
ü
ü
302
USB power sensor support
ü
ü
ü
310
Built-in power meter
ü
ü
ü
330
Pulse meas. with USB peak power sensor
ü
ü
ü
System features
030
Remote control capability
ü
ü
ü
307
GPS receiver
ü
ü
ü
309
DC bias variable-voltage source
ü
ü
ü
Notes:
Base model means that the functionality listed is the primary function of that instrument. For example, on the N991xA or N995xA combo analyzers, cable and
antenna analysis is the standard function included with every N991xA or N995xA.
1. Option 305 is not available on the N993xA or N996xA. However, a subset of cable and antenna analyzer measurements, return loss and VSWR, is available
as Option 320.
2. Option 320 is not applicable to N991xA, N995xA, or N992xA. The reflection measurements of return loss and VSWR are included with every N991xA,
N995xA, and N992xA. So there is no need for an Option 320 on these analyzers.
3. On the N991xA or N995xA analyzers, order Options 233 and 210 to obtain a tracking generator with the spectrum analyzer. There is no Option 220 on the
N991xA or N995xA analyzers. To obtain tracking generator capability, you need Options 233 and 210. Option 233 provides the spectrum analyzer capability
and Option 210 the “tracking” capability.
26 | Keysight | FieldFox Handheld Analyzers – Technical Overview
Specifications in Brief
See the FieldFox Handheld Analyzer Data Sheet for a complete listing of the specifications:
http://literature.cdn.keysight.com/litweb/pdf/5990-9783EN.pdf
Cable and antenna tester is referred to as CAT and vector network analyzer is referenced as VNA in this section.
Model
CAT and VNA frequency
Spectrum analyzer frequency 1
Test port connectors
RF & microwave (combination) analyzers
N9913A
30 kHz to 4 GHz
100 kHz to 4 GHz
Type-N (f)
N9914A
30 kHz to 6.5 GHz
100 kHz to 6.5 GHz
Type-N (f)
N9915A
30 kHz to 9 GHz
100 kHz to 9 GHz
Type-N (f)
N9916A
30 kHz to 14 GHz
100 kHz to 14 GHz
Type-N (f)
N9917A
30 kHz to 18 GHz
100 kHz to 18 GHz
Type-N (f)
N9918A
30 kHz to 26.5 GHz
100 kHz to 26.5 GHz
3.5 mm (m)
N9950A
300 kHz to 32 GHz
9 kHz to 32 GHz
NMD 2.4 mm (m)
N9951A
300 kHz to 44 GHz
9 kHz to 44 GHz
NMD 2.4 mm (m)
N9952A
300 kHz to 50 GHz
9 kHz to 50 GHz
NMD 2.4 mm (m)
N9925A
30 kHz to 9 GHz
–
Type-N (f)
N9926A
30 kHz to 14 GHz
–
Type-N (f)
N9927A
30 kHz to 18 GHz
–
Type-N (f)
N9928A
30 kHz to 26.5 GHz
–
3.5 mm (m)
N9935A
–
100 kHz to 9 GHz
Type-N (f)
N9936A
–
100 kHz to 14 GHz
Type-N (f)
N9937A
–
100 kHz to 18 GHz
Type-N (f)
N9938A
–
100 kHz to 26.5 GHz
Type-N (f) 2
N9960A
–
9 kHz to 32 GHz
NMD 2.4 mm (m)
N9961A
–
9 kHz to 44 GHz
NMD 2.4 mm (m)
N9962A
–
9 kHz to 50 GHz
NMD 2.4 mm (m)
Vector network analyzers
Spectrum analyzers
Notes:
1. Usable to 5 kHz.
2. Order Option 100 for 3.5 mm (m) test port connectors. With N9938A-100, the spectrum analyzer is built with 3.5 mm test port connectors instead of the
standard Type-N (f). Option 100 is a prerequisite for Option 320 for N9938A.
27 | Keysight | FieldFox Handheld Analyzers – Technical Overview
Specifications in Brief (continued)
Cable and antenna analyzer (CAT) and vector network analyzer (VNA)
The performance listed in this section applies to the cable and antenna analyzer (referred to as CAT) and vector network analyzer
(referred to as VNA) capabilities.
N9913 /14 /15 /16 /17 /18A
N9925 /26 /27 /28A
Model
N9950 /51 /52A
Measurements
CAT
Distance-to-fault (dB), return loss, VSWR, DTF (VSWR), cable loss (1 port), optional insertion loss
(2 port), DTF (linear), DTF / return loss dual display
TDR cable measurements
TDR (rho), TDR (ohm), DTF / TDR dual display
VNA T/R
S11, S21 and insertion loss under CAT
VNA full 2 port
S11, S21, S22, S12 mag and phase, VSWR, linear, phase, Smith chart, polar, group delay,
unwrapped phase, real/imaginary
Calibration types
CalReady, 1-port OSL, frequency response, enhanced response, QSOLT, unknown thru 2-port, ECal, QuickCal*
*not available in N995xA models
Number of traces
4
Number of markers
6
Marker functions
Data points
Peak, minimum, target, bandwidth measurement with Q, marker tracking
101, 201, 401, 601, 801, 1001 ,1601, 4001, 10,001
Frequency reference : -10 to 55 °C
Accuracy
± 0.7 ppm (spec) + aging
± 0.4 ppm (typical) + aging
Accuracy, when locked to GPS
Aging Rate
Corrected directivity (with full 2-port calibration)
± 0.01 ppm (spec)
± 1 ppm/year for 20 years (spec), will not exceed ± 3.5 ppm
Using 85520A or 85521A
cal kit
Using 85056D
cal kit
42 dB
–
< 0.5 to 9 GHz
36 dB
–
< 9 to 8 GHz
32 dB
–
< 18 to 26.5 GHz
32 dB
–
≤ 0.5 GHz
≤ 2 GHz
–
42 dB
< 2 to 20 GHz
–
34 dB
< 20 to 40 GHz
–
26 dB
< 40 to 50 GHz
–
26 dB
28 | Keysight | FieldFox Handheld Analyzers – Technical Overview
Specifications in Brief (continued)
Model
N9913 /14 /15 /16 /17 /18A
N9950 /51 /52A
N9925 /26 /27 /28A
Test port output power (high power)
Frequency
Typical
Typical
Port 1 or port 2
30 to 300 kHz
—11 dBm
–
> 300 kHz to 2 MHz
—3 dBm
–
> 2 to 625 MHz
—2 dBm
–
> 625 MHz to 3 GHz
1 dBm
–
—1 dBm
–
> 6.5 to 9 GHz
—2 dBm
–
> 9 to 14 GHz
—4 dBm
–
> 14 to 18 GHz
—6 dBm
–
> 18 to 23 GHz
—10 dBm
–
> 23 to 26.5 GHz
—12 dBm
–
> 3 to 6.5 GHz
Port 1
300 kHz to 2 MHz
Port 2
–
0 dBm
0 dBm
> 2 MHz to 1 GHz
–
2 dBm
2 dBm
> 1 to 6.5 GHz
–
2 dBm
0 dBm
> 6.5 to 18 GHz
–
4 dBm
1 dBm
> 18 to 39 GHz
–
1 dBm
-2 dBm
> 39 to 46 GHz
–
-2 dBm
-5 dBm
> 46 to 50 GHz
–
-4 dBm
-7 dBm
Test port output power (low power)
Port 1 or port 2
30 kHz to 26.5 GHz
500 kHz to 10 MHz
—45 dBm (flattened), nominal
–
–
Port 1
Port 2
-35 dBm
-38 dBm
> 10 MHz to 10 GHz
–
-38 dBm
-42 dBm
> 10 to 20 GHz
–
-43 dBm
-47 dBm
> 20 to 44 GHz
–
-44 dBm
-50 dBm
> 44 to 50 GHz
–
-53 dBm
-55 dBm
Power level accuracy (typical)
± 1.5 dB at —15 dBm
for frequencies > 250 kHz
± 0.7 dB at −15 dBm,
for frequencies > 500 kHz to 10 MHz
± 0.5 dB at −15 dBm,
for frequencies > 10 MHz to 50 GHz
Power step size
Flat power, in 1 dB steps, is available across the whole frequency span (nominal)
29 | Keysight | FieldFox Handheld Analyzers – Technical Overview
Specifications in Brief (continued)
N9913 /14 /15 /16 /17 /18A
N9925 /26 /27 /28A
Model
N9950 /51 /52A
Distance to fault
Range
Range = velocity factor x speed of light x (number of points -1) / frequency span x 2
Number of points auto coupled according to start and stop distance entered.
Range resolution
Resolution = range / (number of points -1)
System dynamic range
1, 2
Frequency
> 300 kHz to 9 GHz
3
: Port 1 or port 2, high power, 300 Hz IF bandwidth, —10 to 55 °C
Spec
Typical
Spec
Typical
95 dB
100 dB
–
–
> 9 to 14 GHz
91 dB
97 dB
–
–
> 14 to 18 GHz
90 dB
94 dB
–
–
> 18 to 20 GHz
87 dB
90 dB
–
–
> 20 to 25 GHz
74 dB
79 dB
–
–
> 25 to 26.5 GHz
65 dB
70 dB
–
–
> 300 kHz to 1 MHz
–
–
–
> 1 to 10 MHz
–
–
–
> 10 MHz to 20 GHz 4
–
–
100 dB
110 dB
> 20 to 44 GHz5
–
–
90 dB
100 dB
> 44 to 50 GHz
–
–
81 dB
90 dB
6
70 dB (nominal)
100 dB (nominal)
Trace noise 7: Port 1 or port 2, high power, 300 Hz IF bandwidth, spec, —10 to 55 °C
Frequency
Magnitude/Phase (dB rms/deg rms)
> 300 kHz to 20 GHz
± 0.004 / ± 0.070
> 20 to 26.5 GHz
± 0.007/ ± 0.140
> 26.5 to 32 GHz
± 0.007/ ± 0.140
> 32 to 50 GHz
± 0.008 / ± 0.220
IF Bandwidth 8
Bandwidth
10 Hz, 30 Hz, 100 Hz, 300 Hz, 1 kHz, 3 kHz, 10 kHz, 30 kHz, 100 kHz
1. System dynamic range is measured in production with loads on test ports after thru normalization, test port output power high.
2. For CAT mode, “Insertion loss (2-port)”, decrease listed dynamic range specifications by 20 dB, as CAT mode IFBW is fixed at 10 kHz. Can obtain full
dynamic range by using S21 measurement in VNA mode with 100 Hz IFBW.
3. < 300 kHz: 63 dB nominal; 2 MHz to 9 MHz: 85 dB spec, 90 dB typical.
4. Decrease by 3 dB between 15 to 15.8 GHz.
5. Decrease by 5 dB between 21.7 to 22.1 GHz
6. Decrease by 4 dB between 44 to 50 GHz
7. For CAT mode, increase trace noise by a factor of 5.7, as CAT mode IFBW is fixed at 10 kHz. Can use averaging in CAT mode to reduce trace noise
or use VNA mode with 300 Hz IFBW.
8. VNA mode only. Recommend using averaging in CAT mode.
30 | Keysight | FieldFox Handheld Analyzers – Technical Overview
Specifications in Brief (continued)
Spectrum analyzer
The performance listed in this section applies to the spectrum analyzer capabilities.
N9913 /14 /15 /16 /17 /18A
N9935 /36 /37 /38A
Model
N9950 /51 /52A
N9960 /61 /62A
Measurements
Spectrum analyzer
Spectrum, channel power, adjacent power, occupied bandwidth, analog demodulation, tune and listen
Number of traces
Same as network analyzer (see page 25)
Number of markers
Same as network analyzer (see page 25)
Interference analysis
Spectrogram, waterfall and record/playback
Input attenuator range
0 to 30 dB, in 5 dB steps
Frequency span
Resolution: 1 Hz
Frequency reference : -10 to 55 ° C
Same as network analyzer (see page 25)
Preamplifier
The preamplifier covers the full-band with nominal gain of 20 dB
Tracking generator
Built in, full-band based on the model maximum frequency
Resolution bandwidth (RBW), range (-3 dB bandwidth)
Zero span: 10 Hz to 5 MHz: 1, 3, 10 sequence
Non zero span: 1 Hz to 5 MHz: 1, 1.5, 2, 3, 5, 7.5, 10 sequence
Video bandwidth (VBW)
1 Hz to 5 MHz in 1, 1.5 , 2, 3, 5, 7.5, 10 sequence
Phase noise: Stability, SSB phase noise at 1 GHz
Offset
Spec (23 ± 5 ºC)
Typical (23 ± 5 ºC)
10 kHz
—106 dBc
—111 dBc
30 kHz
—106 dBc
—108 dBc
100 kHz
—100 dBc
—104 dBc
1 MHz
—110 dBc
—113 dBc
3 MHz
—119 dBc
—122 dBc
5 MHz
—120 dBc
—123 dBc
50 MHz absolute amplitude accuracy (dB)
0 dB attenuation, peak detector, preamplifier off, 300 Hz RBW, all settings auto-coupled. No warm-up required.
Input signal 0 to -35 dBm
Spec (-10 to 55 ºC)
± 0.30 dB
Input signal -5 to -35 dBm
Typical (-10 to 55 ºC)
Spec (-10 to 55 ºC)
Typical (-10 to 55 ºC)
± 0.10 dB
± 0.45 dB
± 0.20 dB
31 | Keysight | FieldFox Handheld Analyzers – Technical Overview
Specifications in Brief (continued)
N9913 /14 /15 /16 /17 /18A
N9935 /36 /37 /38A
Model
N9950 /51 /52A
N9960 /61 /62A
Total absolute amplitude accuracy Temperature (23 ± 5 ºC)
10 dB attenuation, input signal -10 to -5 dBm, peak detector, preamplifier off, 300 Hz RBW, all settings auto-coupled, includes frequency response
uncertainties. No warm-up required.
Spec
Typical
Spec
Typical
± 0.8 dB
± 0.35 dB
–
–
± 1.0 dB
± 0.5 dB
–
–
–
–
± 1.6 dB
± 0.6 dB
> 100 kHz to 2 MHz
–
–
± 1.3 dB
± 0.6 dB
> 2 MHz to 32 GHz
–
–
± 0.8 dB
± 0.3 dB
> 32 to 40 GHz
–
–
± 0.9 dB
± 0.5 dB
> 40 to 43 GHz
–
–
± 1.3 dB
± 0.5 dB
> 43 to 50 GHz
–
–
± 1.4 dB
± 0.5 dB
100 kHz to 18 GHz
> 18 to 26.5 GHz
> 9 to 100 kHz
Displayed average noise level (DANL): RMS detection, log averaging, reference level of —20 dBm, normalized to 1 Hz RBW
Preamp on (23 ± 5 ºC)
2 MHz to 4.5 GHz
1
Spec
Typical
Spec
Typical
—153 dBm
—155 dBm
–
–
> 4.5 to 7 GHz
—149 dBm
—151 dBm
–
–
> 7 to 13 GHz
—147 dBm
—149 dBm
–
–
> 13 to 17 GHz
—143 dBm
—145 dBm
–
–
> 17 to 22 GHz
—140 dBm
—143 dBm
–
–
> 22 to 25 GHz
—134 dBm
—137 dBm
–
–
> 25 to 26.5 GHz
—128 dBm
—131 dBm
–
–
9 kHz to 2 MHz
–
–
—94 dBm
—131 dBm
> 2 MHz to 2.1 GHz
–
–
—153 dBm
—159 dBm
> 2.1 to 2.8 GHz
–
–
—151 dBm
—157 dBm
> 2.8 to 4.5 GHz
–
–
—153 dBm
—158 dBm
> 4.5 to 7 GHz
–
–
—150 dBm
—156 dBm
> 7 to 13 GHz
–
–
—146 dBm
—152 dBm
> 13 to 22 GHz
–
–
—142 dBm
—149 dBm
> 22 to 35 GHz
–
–
—141 dBm
—147 dBm
> 35 to 40 GHz
–
–
—136 dBm
—144 dBm
> 40 to 46 GHz
–
–
—131 dBm
—138 dBm
> 46 to 50 GHz
–
–
—126 dBm
—135 dBm
Third order intermodulation distortion (TOI)
Two -20 dBm signals, 100 kHz spacing at input mixer, —10 to 55 °C
Spec
At 2.4 GHz, +15 dBm
1. Add 4 dB between 2.1 and 2.8 GHz.
Typical
< 1 GHz, +10 dBm
Spec
At 2.4 GHz, +15 dBm
Typical
50 to 500 MHz, +9.5 dBm
–
1 to 7.5 GHz, +15 dBm
–
> 500 MHz to 1 GHz, +13 dBm
–
> 7.5 GHz, +21 dBm
–
> 1 to 2.4 GHz, +16 dBm
–
> 2.4 to 2.6 GHz, +12 dBm
–
> 2.6 GHz, +13 dBm
32 | Keysight | FieldFox Handheld Analyzers – Technical Overview
Real-time spectrum analyzer (RTSA)
Model
N9913 /14 /15 /16 /17 /18A
N9935 /36 /37 /38A
N9950 /51 /52A
N9960 /61 /62A
Real-time analysis
Maximum real-time bandwidth
10 MHz
Resolution bandwidth
1 Hz to 500 kHz
Minimum signal duration with 100% probability of
intercept (POI) at full amplitude accuracy
12 µs
Minimum detectable signal
22 ns
Spurious-free dynamic range across maximum BW
FFT rate
63 dB
120,000 FFT/s (at 10 MHz span)
Min. acquisition time
20 ms (at 10 MHz span)
Max. acquisition time
500 ms (at 10 MHz span)
Traces
Number of traces
4: all four can be active simultaneously and in different states
Detectors
Normal, positive peak, negative peak, sample, average (RMS)
States
Clear/write, max. hold, min. hold, average, view, blank
Markers
Number of markers
6
Type
Marker →
Normal, delta, peak
Peak, next peak, center frequency, reference level, minimum
Trigger
Trigger type
Free run, external video, RF burst, periodic
General information
Model
N9913 /14 /15 /16 /17 /18A
N9925 /26 /27 /28A
N9935 /36 /37 /38A
N9950 /51 /52A
N9960 /61 /62A
Weight
3.0 kg or 6.6 lb including battery
3.2 kg or 7.1 lb including battery
Dimension H x W x D
Battery
Calibration cycle
Warranty
292 x 188 x 72 mm (11.5" x 7.4" x 2.8")
Lithium ion, 10.8 V, 4.6 A-h, 3.5 hours (typical)
1 year
3-year warranty standard on all FieldFox instruments
Environmental
MIL-PRF-28800F Class 2
Operating temperature, storing temperature, storing temperature, operating humidity,
random vibration, functional shock, bench drop
MIL-STD-810G, Method 511.5
This product has been type tested to meet the requirements for operating in explosive
environments in accordance with MIL-STD-810G, Method 511.5, Procedure 1.
Ingress protection
Complies with European EMC directive
This product has been type tested to meet the requirements for ingress protection IP53 in
accordance with IEC/EN 60529 (IP rating for instrument by itself with no cover).
IEC/EN 61326–1
CISPR Pub 11 Group 1, class B, Group 1 limit of CISPR 11:203/EN
55011:2007
AS/NZS CISPR 11
ICES/NMB–001
33 | Keysight | FieldFox Handheld Analyzers – Technical Overview
Accessories in Brief
See the FieldFox Handheld Analyzer Configuration Guide for a comprehensive list of all FieldFox accessories.
http://literature.cdn.keysight.com/litweb/pdf/5990-9836EN.pdf
RF and microwave accesories
Cables
N9910X-709
Phase stable cable (3.5 mm (f) to 3.5 mm (f), 26.5 GHz, 3.28 ft or 1 m)
N9910X-810
Phase stable cable (Type-N (m) to Type-N (m), 6 GHz, 5 ft or 1.5 m)
Calibration kits
N9910X-800
3-in- OSL calibration kit (DC to 6 GHz, Type-N (m) 50 ohm)
85520A
4-in-1 OSLT calibration kit (DC to 26.5 GHz, 3.5 mm (m) 50 ohm)
N4690C
Electronic calibration module (ECal), 300 kHz to 18 GHz, Type-N, 50 ohm, 2-port
85056A
Mechanical calibration kit, DC to 50 GHz, 2.4 mm
85056D
Economy mechanical calibration kit, DC to 50 GHz, 2.4 mm
Antennas
N9910X-820
Directional antenna (multiband 800 MHz to 2.5 GHz, 10 dBi, Type-N (f))
N9910X-821
Telescopic whip antenna (70 MHz to 1 GHz, 10 dBi, BNC (m))
Carry Precision With You
Every piece of gear in your field kit had to prove its worth. Measuring up and earning a
spot is the driving idea behind Keysight’s FieldFox analyzers. They’re equipped to handle
routine maintenance, in-depth troubleshooting and anything in between. Better yet,
FieldFox delivers precise microwave and millimeter-wave measurements—wherever you
need to go. Add FieldFox to your kit and carry precision with you.
Related literature
Number
FieldFox Handheld Analyzers, Data Sheet
5990-9783EN
FieldFox Handheld Analyzers, Configuration Guide
5990-9836EN
FieldFox N9912A RF Analyzer, Technical Overview
5989-8618EN
FieldFox N9912A RF Analyzer, Data Sheet
N9912-90006
FieldFox N9923A RF Vector Network Analyzer, Technical Overview
5990-5087EN
FieldFox N9923A RF Vector Network Analyzer, Data Sheet
5990-5363EN
Download application notes, watch videos, and learn more:
www.keysight.com/find/fieldfox
34 | Keysight | FieldFox Handheld Analyzers – Technical Overview
Evolving
Our unique combination of hardware, software, support, and people can help
you reach your next breakthrough. We are unlocking the future of technology.
From Hewlett-Packard to Agilent to Keysight
myKeysight
www.keysight.com/find/mykeysight
A personalized view into the information most relevant to you.
Keysight Infoline
www.keysight.com/find/Infoline
Keysight’s insight to best in class information management. Free access to
your Keysight equipment company reports and e-library.
KEYSIGHT
SERVICES
Keysight Services
www.keysight.com/find/service
Our deep offering in design, test, and measurement services deploys an
industry-leading array of people, processes, and tools. The result? We help
you implement new technologies and engineer improved processes that
lower costs.
Three-Year Warranty
www.keysight.com/find/ThreeYearWarranty
Keysight’s committed to superior product quality and lower total cost
of ownership. Keysight is the only test and measurement company with
three-year warranty standard on all instruments, worldwide. And, we provide
a one-year warranty on many accessories, calibration devices, systems and
custom products.
For more information on Keysight
Technologies’ products, applications or
services, please contact your local Keysight
office. The complete list is available at:
www.keysight.com/find/contactus
Americas
Canada
Brazil
Mexico
United States
(877) 894 4414
55 11 3351 7010
001 800 254 2440
(800) 829 4444
Asia Pacific
Australia
China
Hong Kong
India
Japan
Korea
Malaysia
Singapore
Taiwan
Other AP Countries
1 800 629 485
800 810 0189
800 938 693
1 800 11 2626
0120 (421) 345
080 769 0800
1 800 888 848
1 800 375 8100
0800 047 866
(65) 6375 8100
Europe & Middle East
Austria
Belgium
Finland
France
Germany
Ireland
Israel
Italy
Luxembourg
Netherlands
Russia
Spain
Sweden
Switzerland
United Kingdom
0800 001122
0800 58580
0800 523252
0805 980333
0800 6270999
1800 832700
1 809 343051
800 599100
+32 800 58580
0800 0233200
8800 5009286
800 000154
0200 882255
0800 805353
Opt. 1 (DE)
Opt. 2 (FR)
Opt. 3 (IT)
0800 0260637
Keysight Assurance Plans
www.keysight.com/find/AssurancePlans
Up to ten years of protection and no budgetary surprises to ensure your
instruments are operating to specification, so you can rely on accurate
measurements.
For other unlisted countries:
www.keysight.com/find/contactus
Keysight Channel Partners
www.keysight.com/find/channelpartners
Get the best of both worlds: Keysight’s measurement expertise and product
breadth, combined with channel partner convenience.
DEKRA Certified
(BP-06-08-16)
ISO9001 Quality Management System
www.keysight.com/go/quality
Keysight Technologies, Inc.
DEKRA Certified ISO 9001:2015
Quality Management System
This information is subject to change without notice.
© Keysight Technologies, 2012 – 2016
Published in USA, August 17, 2016
5992-0772EN
www.keysight.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement