air quality instruments
AIR QUALITY
INSTRUMENTS
Handheld Anamometers
Anemomaster LITE 6006
Compact and Lightweight Hotwire Anemometer
Anemomaster Professional / Standard 6036/6035
Climomaster 6501
Anemomaster 6812, 6813, 6815
Anemomaster 6113
TABmaster 6710
Anemomaster 6162
Multi-Channel Measuring Instruments
4 Channel Anemomaster 1570
Multi-Channel Anemomaster 1550 & 1560
IAQ & Environmental Monitors
Handheld IAQ Monitor 2211
Thermohygrometer Model 6841
Handheld Odor Monitor OMX
Air Aide AA-3500
EVM Environmental Monitors
HAZ-SCANNER Indoor Environmental Monitoring Station
HAZ-SCANNER Wireless Environmental Perimeter Air
Station
Ambient Air Quality Monitor AQM60
Particle & Dust Monitors
Handheld Laser Particle Counter 3887
Handheld Laser Particle Counter 3886 GEO-α
Portable Particle Counter 3910
Handheld Condensation Particle Counter 3800
HAZ-DUST IV Particulate Monitor
HAZ-DUST Real-Time Particulate Monitor
EPAM 5000
EPAM 7500
Digital Dust Monitor 3443
HAZ-DUST VDM-7500
Piezobalace Dust Monitor 3521 / 3522
Dust Sentry
Portable Aerosol Mobility Spectrometer (PAMS)
www.conceptcontrols.com
202
202
202
203
204
204
205
205
206
206
207
207
208
208
209
210
211
212
213
213
213
214
214
215
215
216
216
216
217
217
218
218
201
AIR QUALITY
Handheld Anamometers
Anemomaster LITE 6006
NEW
Compact and Lightweight Hotwire Anemometer
Features:
• Broad measurement range
• Detachable probe for zero
downtime calibration or
replacement
• Temperature compensation circuit
for high accuracy
• Display readings in both metric
and imperial units
• Compact and extremely durable
• Low price, Kanomax quality
throughout
• Highly accurate, long-life
Platinum sensor
• Single button multi-function switch for easy one-hand
operation of power on/off, set time constant, read
temperature, hold result
Air
Temperature
Air Velocity
Specifications:
Range
2 to 3,940 fpm (0.01 to 20.0m/s)
Accuracy
+/- 5% of reading or +/- 0.015 m/s
whichever is greater
Response Time
Less than 1 second at 196 fpm (1m/
sec), 90% response
Resolution
0.01 m/s (@ 0.01 to 9.99 m/s)
Range
0.1 m/sec (@10.0 to 20.0 m/s)
Accuracy
-4 to 158°F (-20 to 70°C)
Response Time
+/-2°F (1°C)
Resolution
Less than 30 seconds at 196 fpm (1 m/
sec), 90% response
Power Supply
0.2 F (0.1 C)
Battery Life
4 x AA batteries
Operating
Environment
Main Unit
41 to 104°F (5 to 40°C)
Probe
-4 to 158°F (-20 to 70°C)
Storage Environment
Dimensions
Main Unit
Probe
14 to 122°F (-10 to 50°C)
2.4"(60mm) x 4.7"(120mm) x
1.2"(30mm)
Probe: 0.24" or 0.40"(6 or 10mm)
diameter x 7.9"(200mm) length
Probe cable: 0.13”(3.3mm) diameter x
59”(1,500mm) length
0.4 lbs (180 g)
Accessories
Operation Manual, AA Batteries,
Extension Rod, Carrying Case, NIST
Certificate
202
NEW
Features:
• Simultaneously measures and
displays air velocity and air
temperature
• Telescopic articulating probe
makes it easy to take traverse
measurements at ceiling ducts
and other hard to reach places
• Datalogging function with storage
capacity of up to 1500 records
which allows users to work longer
before pausing to upload data
to a PC. (Model 6036)
• USB connection, easy to upload
to your PC or laptop. (Model 6036)
• Highly Visible blacklit display
• The new Anemomaster offers an optional hands-free case
that can be comfortably worn by the contractor
Specifications:
Model
Model 6036
Model 6035
Probe Type
Telescopic and
Articulating Tip
Telescopic
Air Velocity
Volumetric
Flowrate
Range
2 to 6,000 FPM (0.01 to 30.0 m/s)
Accuracy
+/- 3.0% of reading or 0.015 m/s
whichever is greater
Imperial
9031 CFM (at 20 FPM)
2,709,360 CFM (at 6000 FPM)
Metric
2,341 m3/s (at 0.1 m/s)
702,270 m3/s (at 30.0 m/s)
Duct Size
Temperature
Weight
Options
Anemomaster Professional /
Standard 6036/6035
0 to 2550 mm
0 to 255 inches
Range
-4 to 158°F (-20 to 70°C)
Accuracy
+/- 1°F or +/- 0.5°C
Differential
Pressure
option
Range
-5.00 to +5.00 KPa
Accuracy
+/- (3.0 % of reading +/- 0.01) KPa
Interface
Digital
USB and RS232C
(for print-out)
Analog
option
DC 0 to 3 V (only for air velocity
measurements)
RS232C (for printout)
Data Storage Capacity
Up to 1500
records
Power Supply
6 x AA Batteries or AC Adapter
Standard Accessories
Carrying Case, Operation Manual, AA
Batteries, AC Adapter
NIST Certificate
Options
Analog Output, Pressure sensor option,
Portable Printer, Printer Cable, Rolled Paper for printer
Spare Probe
www.conceptcontrols.com
n/a
Handheld Anamometers
Climomaster 6501
NEW
Most Accurate Hot-Wire Anemometer of its Kind
Features:
• Probe Compatibility feature allows you to have spare probes
• Automatic Flow Rate Calculation function
• USB connection to PC
• Large data storage, stores up to 20,000 measurements
• Differential Pressure available as an option
• One probe simultaneously measures air velocity, air temperature, relative humidity, and airflow rate
• 7 different detachable probes available, including a low air velocity, omni-directional probe
• Detachable probes allow you to share the main unit or the probes
• Optional Software displays real-time measurements in table, graphic, and spreadsheet formats
Specifications:
Model
6531
Air Velocity
Range
6541
6542
6551
Accuracy
Air Temperature
6533
6543
6561
10 to 1000 fpm
20 to 9840
fpm
(0.05 to 5.00 m/s)
(0.1 to 50
m/s)
+/- (2% of reading +/- 0.0125) m/s
Range
-4 to 158°F (-20 to 70°C)
Accuracy
Relative Humidity
6552
20 to 6000 fpm (0.10 to 30.0 m/s)
+/- 1°F (+/- 0.5 °C)
Range
2 to 98%RH (Model A531, A533)
Accuracy
+/- 2 %RH
Differential Pressure
(Option)
Range
Output
Digital
USB
Analog
DC 0 to 1 V (Option)
-5.00 to +5.00 kPa
Accuracy
+/- (3% of reading +0.01) kPa
Datalogging
Stores up to 20,000 measurement data
Power Supply
6 x AA Batteries / AC Adapter (100 to 240 V)
Weight
0.9 lbs (400 g)
Standard Accessories
Option
Carrying Case, Operation Manual, AA Batteries, 2m Probe Cable, NIST Certificate
Spare Probes, Analog Output, Pressure Sensor, Extention Rod Printer, Printer Cable, PC Communcation Cable,
Windows Software, AC Adapter
Probe Options:
Probe
6531
6541
6561
6542
6533
6543
6551
6552
HVAC
Testing, IAQ
Investigation
HVAC Testing
High Velocity
Applications
HVAC Testing,
Manufacturing
Process Control
Cleanroom
Certification,
HEPA Filter
Performance
Testing,
Turbulent Air
Testing
Cleanroom
Certification,
HEPA Filter
Performance
Testing,
Turbulent Air
Testing
Heat Sink
Cooling
Efficiency
Testing, Airflow
Measurements
in tight spaces
Heat Sink
Cooling
Efficiency
Testing, Airflow
Measurements
in tight spaces
Probe Tip
Applications
www.conceptcontrols.com
203
AIR QUALITY
Anemomaster 6812, 6813, 6815
Anemomaster 6113
Features:
• HVAC Testing
• IAQ Investigations
• Industrial Hygiene
• Cleanroom Testing
• Display switchable in m/s (MPS)
or ft/min (FPM) for
air velocity and cubic ft/min (CFM) or cubic metre/hr
(CMH) for calculated air volume flow. Very high accuracy
due to use of microprocessor digital memory for maximum
and minimum values
• Average measurements over two or sixteen seconds for
air velocity
• Display hold for easy reading of measurements
• Long battery life
Features:
• Probe Compatibility feature
allows utilization of a spare
probe
• Simultaneously measures
air velocity, temperature, and
pressure measurements
• Large, easy-to-read LCD
• Quick printing of measurements at site
• Simple operation with buttons for printing and calculation
• Easily keeps record of measurements
• Suitable for measurements inside ducts
Multi-Function Thermal Anemometer
Rotating Vane Anemomasters
Specifications:
Model
Air Velocity
6812
Probe AP275
Probe AP100
Accuracy
Relative
Humidity
6815
±1.0% of Reading ±1 digit
Resolution
Temp.
6813
40 to 7800 FPM (0.2 to 40 m/s)
60 to 6800 FPM (0.3 to 35 m/s)
1 FPM or 0.01 m/s
Air Velocity
Probe
Optional Temp
Probe
Accuracy
-
Resolution
-
Range
-
-22 to 212 F (-30 to
100C)
-139 to 392 F (-95 to
200C)
±0.3o±0.2% of Reading
in oF
0.1 F or 0.1o(1 F below
-99.9 F)
5.0 to 95.0 %RH
Accuracy
-
±2.0 %RH
Resolution
-
0.1 %RH
Display
-
0.5 inch LCD, 4 digits with LED
Backlight
Instrument: 32 to 125F (0 to 50C)
Operating
Temp.
Probe: -4 to 212F (-20 to 100C)
Power Supply
Operating
Time
(Battery)
Dimensions
3 AA Alkaline Batteries
Approximately 150 hours
Instrument
Probe AP275
W 3.2 x D 1.5 x H 6.5 inches (8.2 x 3.8
x 16.5 cm)
2.75 inch diameter
Probe AP100
RH/Temp
Probe
Standard Accessories
204
1.00 inch diameter
-
6 inch x 1 inch diameter
1 x Rotating Vane Probe Head, your
choice of AP275 or AP100 3 x AA 1.5V
Alkaline Batteries, Operation Manual,
Carrying Case Extension Rod w/
Handle Grip, Flexible Rod HTP 201
combination RH / Temp Probe (avail.
for 6815)
Specifications:
Air Velocity
20 to 9840 fpm (0.10 to 50.0 m/s)
+/-(3% of reading +20fpm (0.1m/s))
Air Temp.
32 to 212ºF (0 to 100ºC)
+/-2.0ºF (1.0ºC)
Pressure
-5.00 to +5.00kPa
(Option)
+/-(3% of reading +0.01)kPa
Measuring
Display hold, time constant setting (1,
Functions
5, or 10 sec.), remaining battery life
(5 steps), measuring unit setting (m/s,
fpm, Celsius, Fahrenheit, kPa).
Data Storage Instantaneous storage, average (over 60
sec max), Storage 100 max
Calculation
Max. and min. values, averaging, raw
data display
Display
Calendar function, air velocity bar
graph display
Outputs
Digital
RS-232C (4800, 9600, 19200, 38400bps)
Output
for communication w/ PC
Printer
Printing calculation results and
Output
measurements
Analog
DC 0 to 1V (1ch. Selected from air
Output
velocity, temp. and pressure)
(Option)
Power Supply
6 × 1.5 volt C cells (Mn, alkaline, or
Ni-Cd)
Battery Life
10 hours continuous operation (with
alkaline batteries, at 5m/s, 20ºC,
without printer use)
Operating
Main Body
41 to 104ºF (5 to 40ºC)
Environment
Probe
32 to 212ºF (0 to 100ºC)
Storage Environment
41 to 104ºF (5 to 40ºC)
Weight (incl. batteries)
Approx. 2.2 lbs (Approx. 1000 g)
Dimensions
7.9”x5.9”x3.9” (200x150x100mm)
Standard Kit
1 x operation manual, 6 x 1.5V Mn C
cells, 1 x probe with 2-meter (6.6-feet)
cable, 1 x extension rod, 1 x shoulder
strap
Optional Accessories
Spare Probe, Analog Output,
Pressure Measurement, Printer
Paper, Communication Cable, Data
Management Software, AC Adapter
www.conceptcontrols.com
Range
Accuracy
Range
Accuracy
Range
Accuracy
Settings
Handheld Anamometers
TABmaster 6710
Anemomaster 6162
NEW
Capture Hood
Middle and High Temperature Anemometer
The TABmaster is the perfect tool for
accurate supply and return airflow
measurements. Interchangeable hoods
make it a snap to sample the air for any
duct size. The unit is lightweight and easy
to handle.The full colour screen can be
tilted so it’s always at the optimal viewing
angle regardless of height.
Features:
• 23 to 2500 cfm (40 to 4250 m3/h) range
• Simultaneously measures and displays air flow,
temperature and humidity
• Displays the direction of the airflow as well as the velocity
• Store up to 3,000 measurements
• Advanced storage feature allows you to store multiple
measurements under a single ID#
• Easy one-person setup and use
• Five hood sizes make it easy to pick one that fits your duct
• Built-in back pressure compensation ensures accuracy for
large volumetric flow measurements
• Competitive economic price with professional-grade
features
Specifications:
Airflow Measuring Range
23 to 2500 CFM (40 to 4250
m3/h)
Accuracy
3% of measuring +/- 10 m3/h
Resolution
1 m3/h
Temperature Measuring Range
32 to 122°F (0 to 50°C)
Accuracy
+/- 1°F (0 to 50°C)
Resolution
0.1°C
Humidity Measuring Range
0-100% RH
Accuracy
+/- 3.0 %RH
Resolution
0.1 %RH
Standard Hood Dimensions
610x610mm
Optional Hood Dimensions
610x1220mm, 305x1220mm,
500x500mm, 915x915mm,
915x610mm
Power Supply
4 x AA batteries or AC Adapter
Weight & Dimensions
7.9 lbs (3.6 kg), Main Body: 3.4"
x 7.4" x 1.6"
Features:
• Simultaneous display of air velocity
and temperature
• Improved response time by the
addition of secondary temperature
compensation circuit
• Easy review of time history by graphic display
• Memory function of maximum 999 separate measurement
data
• RS-232 C serial interface for connection to PC. Analog
output, and remote control terminal equipped
• Probe Compatibility feature allows you to change the
probe easily
Specifications:
Model
Measuring
Range
Measuring
Accuracy
Temp.
Compensation
Accuracy (Air
Velocity)
Heatresistance of
Cable
Length of
Cable
Extension Rod
(Option)
Probe
Dimensions
Display
Input/output
Terminal
Power Supply
Operating
Temp.
Battery Life
Dimensions
Weight
www.conceptcontrols.com
Probe Model 0203
Probe Model 0204
(for middle temp)
(for high temp)
32-392oF (0-200oC)
32-752oF (0-400oC)
40-9840fpm (0.2-50m/s): 32-212oF (0-100oC)
80 .9840fpm (0.4-50m/s): 212-392oF (100-200oC)
138-9840fpm (0.7-50m/s):
-392-572oF (200-300oC)
197-9840fpm (1.0-50m/s):
572-752oF (300-400oC)
-Air velocity: +/-3%F.S.
Air temperature: +/-(1%rdg+1oC)
Less than 984fpm (5m/s):
Less than 984fpm (5m/s):
+/-10%F.S. 984fpm(5m/s) to +/-15%F.S. 984fpm(5m/s) to
9,840fpm(50m/s): +/-6%F.S. 9,840fpm(50m/s): +/-10%F.S.
Teflon coating (Probe side): 392oF (200oC)
Vinyl code (Extension cable): 176oF (80oC)
Teflon coating 4.9ft (1.5m) Vinyl Teflon coating 7.5ft (2.3m) Vinyl
code 16.4ft (5m)
code 32.8 (10m)
0.65”(MAX)x31.5”
0.87”(MAX)x81.5”
(16.5x800mm)
(22x2070mm)
Dimension: φ0.43”x8.2”
Dimension: φ0.43”x39.4”
(11x208mm)
(11x1000mm)
Digital (simultaneous display of air velocity and temp)
Remote terminal: START/STOP key
Analog output terminal: Output voltage 0 . 1 V, Output
impedance 47.
Digital output terminal: RS-232C (serial interface)
Dry battery drive: US type (1.5V x 6 pcs = 9V),
Alkaline battery, Mn battery AC adapter: 12.5V, 450mA
(AC100V +/- 10%, 50/60Hz)
41-104oF (5-40oC)
Approx. 8 hours
8.7” x 3.3” x 5.9” 220 x 85 x 150 mm
Main body: Approx. 4.0lbs (1.8kg), Probe Model 0203:
7.1oz(200g), Model 0204: 17.6oz (500g)
205
AIR QUALITY
Multi-Channel Measuring Instruments
4 Channel Anemomaster 1570
Features:
• 4CH simultaneous measurement in a compact body
• Wide probe selection available for various applications
• Can take measurements at high-time-resolution (0.1 sec)
• RS232C terminal for data logging
• Channel display can be switched by the touch of a button
• Probe compatibility saves downtime and shipping cost
• Windows software gives you simultaneous measurement
on air velocity and flow rate
• Measurement data saved in text format for easy
processing using other software such as Excel
Main Body Specifications:
Display
Data Transfer
Software
Function
Burst Mode
Channel Mode
Instant Mode
Average Mode
Output
Digital
Analog
Main Body Operation Temp.
External Dimensions
Weight
Power Supply
Standard Kit
LCD display
Transfers data of all channels
Transfers data of specific
channel only
Displays instantaneous values
every specified sampling time
Displays average values of a
specified sampling time
RS 232C (Baud rate 9600bps
fixed)
0-5 V
41-104ºF (5-40ºC)
7.8” x 10.2” x 2.8” (200 x 260
x 70mm)
5.7 lbs (Approx. 2.6 kg)
AC 85V – 276V 50Hz/60Hz
RS-232 cable, Power cable,
2xFuse, Data Processing
Software
Multi-Channel Anemomaster 1550 &
1560
Real-Time Air Quality Monitoring System
Features:
• One unit of Model 1550 has 64 Channels for air velocity
• For a larger system, connect up to 5 units in a cascade
and add a computer for control
• Up to 320 channels of measuring points
• Flexibility in system configuration means greater freedom,
simplicity, and efficiency in measurement
Specifications:
Model
Display
0962-00 / 0963-00 0964-01 / 0964-02
20-1000fpm: +/20-1000fpm: +/20fpm
30fpm
(0.1-4.99m/s: +/- (0.1-4.99m/s: +/0.1m/s)
0.15m/s)
1000-2000fpm:
1000-2000fpm:
+/-40fpm
+/-60fpm
(5.00-9.99m/s:
(5.00-9.99m/s:
Measuring
+/-0.2m/s)
+/-0.3m/s)
Range &
2000-5000fpm:
2000-5000fpm:
Accuracy
+/-100fpm
+/-150fpm
(10.0-24.9m/s:
(10.0-24.9m/s:
+/-0.5m/s)
+/-0.75m/s)
5000-10000fpm: 5000-10000fpm:
m+/-200fpm
m+/-300fpm
(25.0-50.0m/s:
(25.0-50.0m/s:
+/-1.0m/s)
+/-1.5m/s)
Temp Comp
41 – 176ºF (5 – 80ºC)
Response
Time
206
Approx. 1 sec
Approx. 3 sec
0965-00 to -08
20-1000fpm: +/30fpm
(0.1-4.99m/s: +/0.15m/s)
1000-2000fpm:
+/-60fpm
(5.00-9.99m/s:
+/-0.3m/s)
2000-5000fpm:
+/-120fpm
(10.0-25.0m/s:
+/-0.6m/s)
1560
LCD (with backlight) simultaneously displays on a
module basis
MAN: Select modules by operating the UP/DOWN
switches
AUTO: Automatically selects modules every 2
seconds to display data
Functions
Burst Mode: Transfers data of all channels at high
speed
Channel Mode: Transfers data of the specific
channel only
Probe Specifications:
Model
1550
Data Selection: Outputs instantaneous values
every specified sampling time, and outputs the
average
Interface
Data transfer: RS232C (standard)
Extended RS232C (optional)
GP-IB (optional)
Baud Rate: 300, 600, 1200, 2400, 4800, 9600,
19200bps (selectable)
Printer output: Centronics
Dimensions
Weight
Approx. 7 sec
www.conceptcontrols.com
16.9” x 19.6” x 5.5” (430 x
500 x 140 mm)
8.9” x 12.8” x 5.5” (226 x
325 x 140mm)
Approx. 22lbs (10kg)
Approx. 11lbs (5kg)
IAQ & ENVIRONMENTAL MONITORS
IAQ & Environmental Monitors
Handheld IAQ Monitor 2211
Thermohygrometer Model 6841
Features:
• Simultaneously measures and data
logs multiple parameters such as:
CO, CO2, temperature, relative
humidity, to monitor indoor air
quality conditions
• Calculates Dew Point, Web Bulb
Temperature, Absolute Humidity,
Humidity Ratio and % Outside Air
• Built-in memory allows user to store multiple point
measurements. Equipped with RS232C terminal
• Easy user calibration with built-in calibration function
• Capable to continuously monitor parameters via PC
• Large LCD shows multiple parameters at a glance
Features:
• Ultralight and palm-size
• Easy to use (Select
temperature, humidity, or
power on/off)
Specifications:
Measuring Object
Measuring range
Display resolution
Specifications:
CO
CO2
Temp.
Relative
Humidity
Function
Output
Range
Accuracy
0 to 500PPM
Clean airflow
Temperature
-4 to 113ºF (-20 to 45ºC)
Humidity
5 to 95%RH
Temperature
0.1ºF or 0.1ºC
Humidity
0.1%RH
Temperature
+/-0.9ºF (+/-0.5ºC)
Humidity
+/-3%RH
Accuracy
+/-3% of reading or +/-3PPM whichever
is greater
Responsiveness
30 sec
Resolution
0.1PPM: 0-99PPM 1PPM: 100-500 PPM
Measuring Function
Conversion between ºF and ºC
Range
0 to 5000PPM
Dimension
Main Unit
Accuracy
+/-3% of reading or+/-50PPM whichever
is greater
Approx. 2.4” x 4.7” x 1.3” (60 x
120 x 34mm)
Probe
Approx. φ19 x 170mm
Resolution
1PPM
Cable
Approx. φ3.3 x 1.5m
Range
- 4 to 140F (-20 to 60C)
Accuracy
+/- 1F (+/-0.5C)
Resolution
0.1F (0.1C )
Range
2 to 98%RH
Accuracy
2 to 80%RH:±2%RH, 80 to
98%RH:±3%RH
Resolution
0.1%RH
Power Supply
Operating
Environment
Normal Mode Normal measuring (do not store and
calculate the data). Relative humidity, CO,
CO2, Dew point, Wet bulb temperature,
Absolute humidity and Humidity Ratio.
Calculation
Mode
Store the data, and calculate the
maximum, minimum and average value.
% OA Mode
Measure ventilation ratio (Ask for
ventilation ratio by calculating from
temperature and CO2 value).
Data Output
Mode
Perform re-calculation of stored data and
output of data to PC and Printer.
Calibration
Mode
Perform the calibration of CO and CO2.
Digital
RS232C
Analog
(option)
DC 0 to 1V
AAA Battery x 4 (Mn, Alkaline,
or Ni-Cd)
Main Unit
41 to 104ºF (5 to 40ºC)
Probe
-4 to 113ºF (-20 to 45ºC)
Storage
Temperature
14 to 122ºF (-10 to 50ºC)
Weight (including batteries)
Approx. 6.3oz (180g)
Accessories
Operation Manual, AA batteries
Options
Carrying Case
www.conceptcontrols.com
207
AIR QUALITY
Handheld Odor Monitor OMX
NEW
Features:
• Numerical value for relative strength of
smell
• Numerical value for classification of
smell
• Handheld odor meter is ideal for before
and after applications, such as air
purification and cleaning service.
• Real-time sampling mode displays odor
change continuously
• Memory sampling mode saves data
based on the selected sampling rate.
(up to 32732 data, 511 files)
• Battery operated with 7 hrs continuous
usage
The Air-Aide AA-3500 Airborne Particulate Monitor provides
accurate and instantaneous display of concentration readings on
lung damaging particulates and aerosols. AA-3500 is a portable
handheld survey tool for measuring lung damaging particulate
matter. The unique sensor design has applications in indoor
air quality (IAQ), HVAC, environmental and industrial hygiene.
Results are immediately displayed and stored in memory.
The supplied PC software allows for graphical and statistical
representation of the total dust generating process, eliminating
the need for repetitive and costly filter gravimetric laboratory
analysis.
Specifications:
Model
OMX-SRM
OMX-ADM
OMX-TDM
Detection
Method
Two Semiconductor Gas Sensors
Sampling
Method
Continuous Sampling with Built-in Air Pump
Object Gas
Ethanol,
Acetone,
Hydrogen, etc
Hydrogen
Sulfide, Methyl
Mercaptan,
Ammonia, etc
TVOC
(Toluene), etc
Odor Strength
Level
0.0 to 999
0 to 999
0.0 to 9999
(µg/m3)
Classification
Class 0 to 90
Odor Intensity
2.5 to 5.0
n/a
Power Supply
Memory
Capacity
Options:
• Zero Filter
• Calibration Span Reference insert
• Size selective impactor: PM-10, PM-2.5, PM-1.0 and ISO
Respirable (4.0µm)
Up to 32732 data
0 to 40 ºC (32 to 104 ºF) * No condensation
Operating
Temperature
-10 to 50 ºC (14 to 122 ºF) * No condensation
Dimensions
74 (W) x 167.5 (L) x 35 (H) mm
208
Features:
• Direct reading with high resolutions and stability of airborne
particulates
• Active sample flow using a long-life air sampling pump for
particle size separation
• Location codes, user-defined audible alarm
• Size selective inlet, PM-10, PM-2.5, PM-1.0 and ISO
respirable (4.0µm)
• Rechargeable battery – unit runs on AC or DC power
• Large data storage capacity – can run continuously for 15
months without downloading
• On-screen programming of sampling and data storage
parameters
• Downloading of stored data through an RS232 port; PCbased software supplied to download and graph stored data
• Selection of different built-in calibration factors for fine and
coarse particulate matter
• CE, ETL approved
• Optional Wireless Data Transmission to computer
• Interfaces to wireless Video Dust Monitoring System Model
VDM-7500
4 x AA batteries or AC adaptor *Battery life for
continuous measurement is approx. 7 hours
Storage
Temperature
Weight
Air Aide AA-3500
250g (without batteries)
www.conceptcontrols.com
IAQ & ENVIRONMENTAL MONITORS
EVM Environmental Monitors
RENTAL
Concept Controls Inc.
The 3M™ EVM Series monitors both particulates and air quality in one compact instrument. From healthcare and manufacturing to
construction and military applications, the EVM Series provides a lower cost of ownership by combining three instruments into one. Its
user-friendly interface, patented dial-in rotary impactor, and advanced reporting and analysis features make it a particulate and IAQ area
monitoring instrument of choice for industrial hygienists and safety professionals worldwide.
EVM-7 Features:
• Intuitive, User-Friendly Controls
Its large display and buttons, simple screens, straightforward commands and robust software
solutions put all of the EVM-7’s capabilities right at your fingertips.
• Simultaneous Measurement of Particulate and Gas Concentrations
Reduces the need for multiple instruments and lowers the cost of ownership.
• Dial-in Rotary Impactor
Twist and click selection of particulate settings: PM2.5, PM4, PM10 or TSP.*
Eliminates disassembly and reduces the need for external cyclones.
• 90° Light Scattering Photometer
Provides real-time measurement of particulates.
• Built-in Sampling Pump for Gravimetric Analysis
Allows user to insert a 25 or 37 mm cassette to capture particulates for laboratory testing.
Incorporates the effects of protective clothing and personal physical condition.
Specifications:
PART NO.
DESCRIPTION
EVM-7
EVM-7 Advanced Particulate and Air Quality Monitor
Includes base model with PID Sensor, CO2 Sensor, one Dummy Sensor (used to seal socket when no sensor is present), two 37mm Gravimetric
Filter Cassettes (for pump protection; one in unit and one spare), 53-263 12V DC Universal Input Power Supply, 53-575 USB Cable, 100-456
Silicone Dielectric Grease for Impactors, 74-080 PID Cleaning Kit, 74-090 10 pack Pump Protection Filters, 74-720 Dust Zero Calibration Filter
Assembly, 74-726 Toxic Calibration Adapter and 74-718 Storage Case. Also available with CO sensor. 3M ID 70-0715-8013-1
EVM-4
EVM-4 Indoor Air Quality Monitor
Includes base model with CO2 Sensor, two Dummy Sensors (used to seal socket when no sensor is present), 53-263 12V DC Universal Input
Power Supply, 53-575 USB Cable, 74-726 Toxic Calibration Adapter and 74-718 Storage Case. Also available with CO sensor. 3M ID 70-07158015-6
EVM-3
EVM-3 Real-Time Direct Reading Particulate Monitor
Includes base model with two 37mm Gravimetric Filter Cassettes (for pump protection; one in unit and one spare), three Dummy Sensors
(used to seal socket when no sensor is present), 53-263 12V DC Universal Input Power Supply, 53-575 USB Cable, 100-456 Silicone Dielectric
Grease for Impactors, 74-090 10 pack Pump Protection Filters, 74-720 Dust Zero Calibration Filter Assembly, and 74-718 Storage Case 3M ID
70-0715-8016-4
AIRPROBE
-10-120
Airprobe-10 Air Velocity Probe Airprobe-10 Kit -Includes Airprobe-10, 74-719 Mounting Bracket, 74-083 Adapter Cable, 53-037 120V AC Charger
and 54-964 Carrying Case 3M ID 70-0715-8017-2
AIRPROBE
-10-220
Airprobe-10 Kit -Includes Airprobe-10, 74-719 Mounting Bracket, 74-083 Adapter Cable, 53-038 220V AC Charger and 54-964 Carrying Case
3M ID 70-0715-8018-0
3M™ EVM-3
3M™ EVM-4
Specializes in real-time direct reading of particulate concentrations.
This tri-sensor instrument utilizes the built-in sampling pump and
dial-in impactors for real-time mass concentration readings.
Multi-sensor instrument designed for indoor air quality investigations.
Simultaneously track, log and monitor multiple indoor air quality
parameters including room air exchange rates and dew point.
EVM-3 measures:
EVM-4 measures:
• Particulates (mass concentration)
• Temperature
• Relative Humidity
•
•
•
•
Toxic Gas (choose from nine sensors)
Relative Humidity
Carbon Dioxide
Temperature
www.conceptcontrols.com
209
AIR QUALITY
HAZ-SCANNER Indoor Environmental Monitoring Station
The portable HAZ-SCANNER Indoor Environmental Monitoring Station (IEMS) is designed to measure critical parameters for indoor
environmental assessments, LEED green building certification, school zone measurements, job task analysis, and occupational health
and safety compliance. The HAZ-SCANNER IEMS displays real-time readings with datalogging capabilities. Configure the IEMS for up to
14 simultaneous critical indoor measurements. Optional wireless data acquisition for continuous unattended sampling for up to one mile is
available. Easily download data to a PC or Mac and create compliance-ready graphical reports with the supplied software.
Ordering Information
Description
Cat. No.
HAZ-SCANNER IEMS includes monitor with particulate
sensor for TSP, impactor for PM10 sampling, CO2, CO,
temperature, and relative humidity sensors, charger,
HazComm Pro Software, cables, CD-ROM with instructions,
and carry case
770-800
Requires calibration using appropriate calibration gas(es) and
regulator sold separately
HAZ-SCANNER IEMS is expandable to up to 14 parameters; see
sensors and meters listed below.
IEMS-specific Optional Meters (Choose up to 5)
Each includes holder to mount meter on tripod accessory
Features:
Air Velocity Meter, 0 to 30 m/s or 0 to 5910 ft/min
770-801
Atomic/Nuclear Radiation Meter, 1 to 19,999 cpm or 0.001
to 100 mR/hr
770-802
ELF Radiation Meter, 1 to 200 mG
770-803
Indoor Light Intensity Meter, 0 to 50,000 lux/0 to 5000
footcandles
770-804
• Standard IEMS configuration measures 5 parameters
including PM10 or TSP particulates, CO2, CO,
temperature, and relative humidity
Nitrogen Dioxide Sensor, 0 to 20 ppm*
770-805
Sulfur Dioxide Sensor, 0 to 50 ppm*
770-806
Oxygen Sensor, 0 to 30%*
770-807
Ozone Sensor, 0 to 0.15 ppm*
770-808
Ozone Sensor, 0 to 5 ppm*
770-818
• Add one or all optional plug and play sensors and/or
IEMS-specific meters (up to 9 sensors/meters total)
Choose from additional toxic gas sensors, PID for
VOCs, or IEMS-specific meters for light intensity, sound/
noise, atomic/nuclear radiation, ELF radiation, and air
velocity
PID for VOCs, 0 to 2000 ppm (isobutylene equivalent)
770-809
IEMS-specific Optional Sensors (Choose up to 4)†
Accessories
Size-selective Impactors
PM1.0
770-811
PM2.5
770-812
PM4.0
770-813
Calibration Standard, particulate
770-207
Calibration Regulator, 1.0 L/min fixed flow, male thread, for
use with 34/58 L aluminum cylinder, required for use with
calibrator gas for toxic gases
770-816
Tripod Stand for HAZ-SCANNER IEMS includes holder for
IEMS
770-814
Alarm for HAZ-SCANNER IEMS
770-815
Wireless Radio Modem, 900 MHz, up to 300 feet
770-505
Wireless Radio Modem, 900 MHz, up to 1500 feet
770-505X
† Hydrocarbon sensors and specialty sensors for nitric oxide, chlorine, hydrogen
cyanide, and hydrogen sulfide are available. Contact SKC; specify gas type when
ordering.
* Additional calibration gas for the specific chemical is required when using
additional toxic gas sensors.
• Direct reading
• Measures and displays data for up to 14 critical
air quality parameters
• Available analog input port for alternative meter
• Interchangeable size-selective impactors are available
for PM1.0, PM2.5, or PM4.0 (close approximation of
respirable)
• In-line standard 37-mm or optional 25-mm gravimetric
filter cassette provides concurrent filter sampling for
chemical and biological analyses
• 1 to 4 L/min internal sample pump
• 8-hour operation with NiMH battery, continuous
operation with AC power
• Displays TWA, STEL, Max, and Min
• Optional alarm indicator light and siren for
user-defined threshold limits
• Removable handheld sensors for spot-checking remote
areas
• Datalogging and optional real-time wireless
data transmission
• Easy-to-use graph and reporting software — compatible
with PC and Mac
210
www.conceptcontrols.com
IAQ & ENVIRONMENTAL MONITORS
HAZ-SCANNER Wireless Environmental Perimeter Air Station
The portable HAZ-SCANNER Wireless Environmental Perimeter Air Station (EPAS) is easily deployed as an ambient air quality monitor
to scan, measure, and document critical EPA criteria pollutants including nitrogen dioxide, carbon monoxide, sulfur dioxide, ozone, carbon
dioxide, particulates, VOCs, and more. The EPAS provides direct readings in real time with datalogging capabilities. The graph and reporting
software are compatible with PC and Mac.
Features:
• Direct Reading
• Build your own station with up to 14 simultaneous air measurements including U.S. EPA criteria
air pollutants
• Standard configuration measures 5 parameters including PM10 or TSP particulates, NO2, CO,
temperature, and relative humidity
• Add one or all optional plug and play sensors and/or EPAS-specific meters (up to 9). Choose
from additional sensors for toxic gas (including hydrocarbons, VOCs, and methane) and biological/
chemical agents, and EPAS-specific meters for solar radiance/UV or IR, barometric pressure, sound/
noise, atomic radiation, ELF radiation, rain, and wind speed/direction
• Available analog input port for alternative meter
• Interchangeable size-selective impactors are available for PM1.0, PM2.5, or PM4.0 (close
approximation of respirable)
• Real-time readings, datalogging capabilities
• Optional wireless data transmission up to 5 miles
• Optional ethernet internet connection for 24/7 data reporting
• Easily portable and deployable
• Battery operated
• Network up to 8 EPAS to one central PC or Mac
• Easy-to-use graph and reporting software compatible with PC and Mac
Ordering Information
Contact a Concept Controls product specialist to build your custom HAZ-SCANNER Wireless EPAS.
PARAMETER
Particulates
VOCs
Toxic Gas: NH3 - Ammonia
Toxic Gas: CO2 - Carbon Dioxide
Toxic Gas: CO - Carbon Monoxide
Toxic Gas: Cl2 - Chlorine
Toxic Gas: Hydrocarbon, CH4 - Methane Specific
Toxic Gas: Non-Methane Hydrocarbons (HC)
Toxic Gas: HCN - Hydrogen Cyanide
Toxic Gas: H2S - Hydrogen Sulfide
Toxic Gas: NO - Nitrogen Oxide
Toxic Gas: NO2 - Nitrogen Dioxide
Toxic Gas: O2 - Oxygen
Toxic Gas: O3 - Ozone
Toxic Gas: SO2 - Sulfur Dioxide
Rainfall/Precipitation
Temperature
Relative Humidity (RH)
Solar Radiance Intensity
Sound and Noise
Atomic Radiation
ELF Radiation
Wind Speed/Direction
Barometric Pressure
Dew Point Temperature
Wet Bulb Temperature
SENSOR
90° infrared light scattering
PID (10.6 eV)
Gas-sensing semiconductor (GSS) technology
NDIR
Electrochemical
Electrochemical
NDIR
NDIR
Electrochemical
Electrochemical
Electrochemical
Electrochemical
Electrochemical
Gas-sensing semiconductor (GSS) technology
Electrochemical
Rain gauge (heated, tipping bucket)
NTC thermister
Thin-film capacitive
Photoiodode
Type 2 SLM
Geiger counter
Sensor with single-axis probe
3-cut anemometer/continuous rotation potentiometric
wind direction vane
Piezo Resistive
Software calculation from RH and Temperature
Capsulated thermistor with wick
www.conceptcontrols.com
MEASUREMENT/CONCENTRATION RANGE
0 to 20,000 µg or 0 to 200 mg/m3
0 to 100 ppm
0 to 100 ppm
0 to 5000 ppm
0 to 100 ppm
0 to 100 ppm
0 to 1% vol., 0 to 10,000 ppm, 0 to 20% LEL
Calibrated for 0 to 20% LEL or selected gas
0 to 100 ppm
0 to 100 ppm
0 to 100 ppm
0 to 5000 ppb (0 to 5 ppm)
0 to 30% vol.
0 to 150 ppb (0 to 0.15 ppm), 0 to 500 ppb (o to 0.5 ppm)
0 to 5000 ppb (0 to 5 ppm)
0 to 5 inches daily
-4° to 140° F (-20° to 60° C)
0 to 100% RH
1110 watts/square meter (W/m))
30 to 135 decibels (dB)
1 to 19,999 counts per min (cpm) or 0.001 to 100 milliRad/hr
1 to 200 milligauss (mG)
0 to 125 mph/5 to 355°
28 to 31 in Hg
-47.2° to 122° F (-44° to 50° C)
3.2° to 122° F (-16° to 50° C)
211
AIR QUALITY
Ambient Air Quality Monitor AQM60
NEW
WIRELESS
The AQM 60 monitors fill the gap between full reference monitoring stations and simple diffusion samplers. Typical applications include traffic
or roadside monitoring, urban air quality measurement and fenceline monitoring of air pollution sources. The AQM60 utilizes proprietary
Analytic GSS Technology to provide high performance within a flexible cost effective package.
The AQM 60 monitors are discreet, highly compact, and deliver precise measurement data for a wide range of ambient pollutants including
O3, NO2, CO, SO2, CO2, VOC, plus PM10 and environmental parameters such as temperature, humidity, wind speed and direction, noise
and other meteorological sensors. Data is stored internally and is also available in real-time via GSM modem, low power radio, ethernet and
other communication options.
Features:
• Analytic GSS technology
• Multiple gas sensors (up to six)
• Temperature and humidity sensors
• Particulate monitor (PM2.5 or PM10)
• Large internal data storage capacity
• Zero and span calibration facility
• Remote diagnostics capabilities
• Weatherproof and compact enclosures
• Thermal management system
• Wind speed and direction anemometer
• Noise and meteorological sensors
• Wireless communication
Environment
Operation Range
10 to 25 C (standard)
-20 to 45 C (with heater or cooler)
10 to 90 %RH (non condensing)
Communications
GSM modem / RF modem / ethernet LAN
Other Sensor
Options
Noise sensors / Particle counters /
Meterological sensors
Power Supply
12 VDC (power subject to configuration) / AC
power module 100 to 250 VAC
Enclosure
Standard: Fibre reinforced polycarbonate
Options: Insulated roadside boxes / Metal
enclosures / Mounting accessories
Dimensions
H 23.6 x W 19.7 x D 9.1in. (600 x 500 x 230 mm)
Weight
33 to 55 lb (15 to 25 kg)
Gas Sensor Modules:
Gas Sensor Modules
Sensor
Range (ppm)
Accuracy
Resolution (ppm)
Power
Ozone
GSS
0 - 0.150
<+/- 0.005 ppm
0.001
2.9 W
Nitrogen dioxide
GSS
0 - 0.200
<+/- 15 %
0.001
12.3 W
Carbon monoxide
GSS
0 - 100
<+/- 5 ppm
0.1
2.5 W
Sulphur dioxide
GSS
0 - 10
<+/- 0.5 ppm
0.01
2.5 W
Non-methane
hydrocarbon
GSS
0 - 25
<+/- 0.5 ppm
0.1
2.5 W
VOC isobutylene
GSS
0 - 25
<+/- 10 %
0.1
2.5 W
VOC isobutylene
PID
0 - 20
<10 %
0.01
1.5 W
Hydrogen sulphide
GSS
0 - 10
<+/- 0.5 ppm
0.01
2.5 W
Carbon dioxide
NDIR
0 - 2000
<40 ppm + 3%
1
1.0 W
Temperature/Humidity Sensor:
Sensor
Range
Temperature
Humidity
Accuracy
Resolution
Power
-20 - 100C
+/- 0.3C @ 25C
0.1C
2.9 W
0 - 100%RH
+/- 2%RH @ 25C
0.1%RH
2.9 W
Particle Monitor Forward light scatter nephelometer
Range
Particle Size
Precision
Accuracy
LT Stability
Cut Points
Power
1 - 2000μg/m
0.1 - 100μm
3μg/m
8% NIOSH 0600
5% of reading
TSP, PM1, PM2.5, PM10
5.2 W
Anemometer Module Sonic or mechanical combination
212
Wind Speed
Wind Direction
Accuracy
Resolution
Power
0 - 160km/h
0 - 360degree
+/- 3% WS, +/- 3degree WD
0.1m/s, 1degree
1.0 W
www.conceptcontrols.com
Particle & Dust monitors
Particle & Dust Monitors
Handheld Laser Particle
Counter 3887
Handheld Laser Particle Counter 3886
GEO-α
RENTAL
Features:
• Displays 3 particle sizes
simultaneously (0.3, 0.5, 5.0 um) in cf
or m3
• Built-in flow sensor (0.1 CFM +/- 10%)
• User can log up to 8,000
measurements with easy transmission
to PC or Printer
• Fits in your palm
• Batteries can be altered with regular
AA alkaline batteries
• Comes with a network capable of up to 8 units using
optional Windows software as a standard accessory
Specifications:
Measuring Particle Size
0.3, 0.5, 5.0um
Light Source
Laser Diode
Counting Efficiency
50% @ 0.3 um; 100% for particles >
0.45 um (per JIS B9921: 1997)
Zero Count
.1 count / 5 minutes (per JIS B9921:
1997)
Coincidence Loss
<5% @ 2,000,000 particles/cf
Flow Rate
0.1 cfm (2.83l/min)
Sampling Time
1 sec to 99 minutes 59 sec (1 sec
increments)
Sampling Frequency
1 to 99 times or Continuous
Count Alarm
1 - 70,000,000 counts
Mode of Measurements
Single / Repeat / Continuous /
Calculation / Remote / ISO <C4
Display
20 letters, 4 lines
Error
Max. concentration, Laser Power,
Flow Rate and Battery
Features:
• Measures 5 particle sizes
simultaneously (0.3, 0.5, 1.0, 3.0
and 5.0 um) in cf or m3, displaying 2
channels
• Built-in flow sensor (0.1 CFM +/10%)
• Temp/RH and Air Velocity probes
available as an option
• Capable of measuring up to 4
parameters in one instrument
Specifications:
5 Size Channels
0.3 um; 0.5 um; 1.0 um; 3.0 um; 5.0um
Flow Rate
0.1 cfm (2.83 l/min)
Light Source
Laser Diode
Calibration
PSL particles in air
Counting Efficiency
50% @ 0.3 um; 100% for particles >
0.45 um (per JIS B9921: 1997)
Zero Count
.1 count / 5 minutes (per JIS B9921:
1997)
Coincidental Loss
<5% @ 2,000,000 particles/cf
Sampling Time
1 sec - 99 min 59 sec, 1 second
increment
Sampling Frequency
1 - 99 or continuous
Count Modes
Single, Repeat, Continuous, Calculation
and Remote
Display
20 letters, 4 line LCD
Interface
RS232C or RS485
Baud Rate
9600 bps
Buffer Memory
500 sample records
Power
AC Adapter
5VDC at 2.5A, 100 - 240VAC, 50 to 60
Hz
Rechargeable
Battery
4 x AA NiMH
Interface
RS232C or RS485
Baud Rate
9600bps
Buffer Memory
8000 measurements
Power Supply
4 x AA NiMH battery or Alkaline, AC
Adapter (100 - 240V)
Vacuum Source
Internal pump, flow controlled
Operating Hours
Approximately 3 hours (NiMH)
Dimensions
Dimensions
4.3” x 7.7” x 2.7” (108 x 196 x 68
mm)
4.5 x 2.8" x 8.5" (115 mm x 70 mm x
211 mm) "
Weight
2.2 lbs (1 kg)
Weight
1.5 lbs (680g)
Accessories
AC Adapter, Zero Filter
Operating Conditions
50 - 95°F (10 -35°C)
Options
Accessories
AC Adapter, Zero Filter, Software,
Communication Cable, 4xAA NiMH,
Battery Charger
Isokinetic Probe, Air Velocity Probe,
Thermal Printer, Temperature/Relative
Humidity Probe, Carrying Case
Options
Printer, Printer Cable, Carrying
Case, Tripod
www.conceptcontrols.com
3.5 hrs with 1600mAh batteries
213
AIR QUALITY
Portable Particle Counter 3910
NEW
Features:
• 50 L/min (1.77 cfm) Flow Rate - Model 3910
• Compliant with ISO 21501-4 and
21 CFR Part 11
• Simultaneous measurements of
6 particle sizes
• Store up to 10,000
measurements
• Stainless enclosure
• 2 year warranty
• Featherlight with an ultra-small
footprint
• Large Colour touchscreen
• Multi-parameter: Particle, Airflow, Temperature, Humidity,
Differential Pressure
• Mulit-standard mode: ISO 14644, FS 209E, BS 5295, EC
GMP
Specifications:
Handheld Condensation Particle
Counter 3800
Features:
• 0.015 μm sensitivity
• Concentration range of 0 to
100,000 particles/cm3
• Programmable datalogging
capabilities
• Power supply can be selected
from alkaline/Ni-MH battery or
AC adapter
• Simple to download the data to your computer via USB
Specifications:
Measuring Particle Size
0.015 to > 1μm
Concentration Range
0 to 100,000 particles/cm³
Counting Efficiency
50nm: 100±20% (15nm: More than
50%)
Zero Count
Less than 1 particle/ cm³
Aerosol Flow: 100cc/min
Channel Sizes
0.3 um, 0.5 um, 1.0 um, 3.0 um, 5.0um,
10.0um
Flow Rate
Flow Rate
50 LPM (Model 3910) / 28.3 LPM (Model
3905)
Alcohol
Supply
Light Source
Laser Diode
Counting Efficiency
50% @ 0.3 um
Zero Count
Less than 1 count / 5 minutes
Interface
Ethernet, USB, Memory card slot (MMC)
Data Storage
10,000 measurement data
Environmental
Sensor
Air Velocity, Temperature, Relative Humidity
and Pressure
Power
AC Adapter
AC 100 - 240 V
Battery
Li-ion Battery
W 7.9 x D 7.9 x H 8.1 inch Weight
14.2 lbs (6.44 kg)
Accessories
Quick-start guide, AC adapter, zero filter,
Isokinetic probe with 79 inch (2m) tubing,
inlet nozzle, data processing software,
memory card, 2 rolls of cleanroom-grade
printer paper, 1 x Li-ion battery and
calibration certificate
Carrying Case, Spare Battery, Battery
Charger, Air Velocity, Temperature, Relative
Humidity Probe , Differential Pressure
Sensor
Uni-Directional
20 to 6000 fpm (0.10 to 30 m/s)
Temperature
-4 to 158°F (-20 to 70°C)
Relative Humidity
2.0 to 98.0 %RH
214
Approx. 5 hours at 23°C (73°F)
Repeat / Program / Counter
Display
Built-in LCD ( 128 x 64 dots)
Interface
USB
Buffer Memory
Max. 10,000 measurements
Power
Supply
Type
6 pieces of AA-size Alkaline / Ni-MH
battery or AC adapter (Input 100 .
240V)
Operating
hours
Approx. 5 hours (by Alkaline
batteries); Approx. 8 hours (by Ni-MH
batteries)
Environmental Operating
Condition
Ambient temperature range: 10 to
35°C (50 to 95°F)
Dimensions
4.7"W x 11"H x 5.1"D (120 x 280 x
130mm)
Weight
Approx. 3.3lbs (1.5kg) (without
batteries)
Standard Accessories
AC adapter, Zero filter , Alkaline
battery x 6, Operation manual,
Software (for Windows), PC
Communication Cable, Carrying Case
Options
Ni-MH battery (1.2V-2500mA) x 6,
Charger x 2, Printer, Printer cable,
Printer AC adapter
Model 6531-2G-P
Air Velocity
100% reagent-grade isopropyl alcohol
Hours per Fill
Mode of Measurements
Optional Probe:
Probe Type
Type
Absolute Pressure Sensor 150 to 1150 hPa
Dimensions
Options
Total Flow: 700cc/min
www.conceptcontrols.com
Particle & Dust monitors
HAZ-DUST IV Particulate Monitor
The HAZ-DUST IV, with new infrared detector, displays
immediate breathing zone measurements and comprehensive
graph reporting of aerosol and dust for industrial hygiene and
environmental air investigations. Operate without a sampling
head for total head measurement (NIOSH 0500) or target
specific particle fractions by installing an inhalable, thoracic, or
respirable sampling head. An in-line 37-mm cassette behind
the sensor may be used to collect a concurrent filter sample for
gravimetric or chemical analysis.
Features:
• Immediate display of
particle concentration in
mg/m3
• Interchangeable
sampling heads
• Operate without a
sampling head for total
head measurement
(NIOSH 0500)
• Internal adjustable sample pump — 1.0 to 3.3 L/min
• In-line cassette directly behind sensor for concurrent filter
sampling
• Audible alarm with adjustable threshold
• Worker comfort
• DustComm Pro Software for downloading, basic trend
analysis, and comprehensive graphical reporting
• Run time over 8 hours with rechargeable NiMH battery
Requires calibration with equipment sold separately, see accessories
At the touch of a button, the HAZ-DUST realtime particulate monitor provides accurate
and instantaneous data on airborne particle
concentration in accordance with NIOSH
Method 0600. Designed for industrial
hygiene, indoor air quality, and hazardous
materials investigations, HAZ-DUST
saves money by eliminating repetitious and
costly gravimetric air sampling and analysis.
Features:
• Easy operation and instantaneous readings in mg/m3
• Selectable dual measuring range feature
• Particulate concentrations between 0.01 and 20 mg/
m3 and from 0.1 to 200 mg/m3
• Easy-to-read digital display
• Highly sensitive - measurements down to 0.01 mg/m3
• Rechargeable 8 hr battery life & low battery indicator
• Unique design provides protection from RFI/EMI
• Lightweight, rugged, and portable
• Optional tripod mounting
• Optional datalogger w/ user-selectable alarm threshold
• Easy-to-use DustComm Pro Software available with
datalogger for downloading, time vs concentration
profiling, and comprehensive graphical reporting
• CE Marked
Specifications:
Ordering Information
Description
HAZ-DUST IV Monitor includes monitor, thoracic head,
in-line filter cassette, carry case, computer cable, battery
charger, HAZ-DUST Media CD with instruction manual,
and DustComm Pro Software
110 - 240 V
HAZ-DUST IV Monitor Kit includes all items listed above
plus GS Cyclone and adapter, IOM and adapter, calibration jar, and standard
110 - 240 V
Sampling Heads
Inhalable Sampling Head and Adapter, IOM Sampler,
mounts on HAZ-DUST IV sensor
Thoracic Sampling Head, mounts on inlet or HAZ-DUST
IV sensor
Respirable Sampling Head, GS-3 Cyclone, mounts on
HAZ-DUST IV sensor
Adapter for Respirable Sampling Head, required when
using GS-3 Cyclone
Accessories
Calibration Standard for Monitor, for verifying span and
optical sensor performance
Calibration Jar, for calibrating and setting pump flow
when using respirable sampling head
Zeroing Accessory, for clean-air zeroing of sensor when
using inhalable sampling head
Zeroing Filter, for use with respirable and thoracic sampling heads
HAZ-DUST Real-Time Particulate
Monitor
Cat. No.
770-4004
770-4004K
770-115A
770-4107
225-103
770-313
770-140
Sensing range:
0.01 to 200 mg/m3
Display:
LCD 3.5 digits mg/m3 concentration
reading
Calibration:
SAE fine test dust compared with NIOSH
0600
Particle size range:
0.1 to 50 µm
Precision:
± 0.02 mg/m3
Accuracy:
± 10% to NIOSH 0600
Power:
NiMH rechargeable battery
Operating time:
> 8 hrs
Charging time:
10 to 12 hrs
Humidity:
95% non-condensing
Dimensions:
9 x 2.75 x 1.5 in
(22.9 x 7.0 x 3.8 cm)
Weight:
1.10 lbs (0.5 kg)
Optional datalogger:
Two-key programmable operation. Realtime clock, display, and user-selectable
alarm threshold. Includes software for
statistics, graphs, and reports. PCcompatible.
Recording time:
1 sec to 15 mo
Sampling rate:
1 sec, 10 sec, 1 min, 10 min, and 30 min
averaging
Signal input:
0 to 2 volt
Output:
RS-232C (9600 baud rate)
225-112
770-4202A
770-4102
www.conceptcontrols.com
215
AIR QUALITY
EPAM 5000
EPAM 7500
The portable HAZ-DUST EPAM5000 particulate monitor is ideal
for ambient, environmental, and
indoor air quality investigations.
The highly sensitive EPAM-5000
uses light scattering to measure
particle
concentration
and
provide real-time determinations
and data recordings of airborne
particle concentration in mg/m3.
Interchangeable size-selective impactors allow PM10, PM2.5,
PM1.0, or TSP monitoring. The unique aerodynamic particle
sizing and optional 47-mm in-line filter holder loaded with
appropriate filter can provide concurrent gravimetric sampling.
Download and store sampling data on a PC for analysis and
reporting using included DustComm Pro Software.
The HAZ-DUST EPAM-7500 portable
monitor and air station gives real-time
measurements of particulate matter,
temperature, and relative humidity in
ambient and indoor air. Interchangeable
size-selective sampling heads allow
PM10, PM2.5, PM1.0, respirable, or
TSP monitoring. Optional accessories
for measuring wind speed and direction
are available. A filter holder positioned
directly behind the optical sensor provides concurrent
gravimetric sampling for cross calibration of optical sensor,
further particulate speciation, and determination of metal and
carbon content.
Features:
• Immediate display and data storage of lung damaging
aerosols
• Provides both real-time and filter gravimetric data.
• Unique aerodynamic particle sizing real-time sensor
and in line 47mm filter cassette which allows concurrent
gravimetric samplings
• High correlation to EPMA PM-10 methods and TEOM*.
• Added value survey sampler for saturation monitoring
studies
• Easy to use Data Analysis Software
• Easy to clean optical sensor with self-purging capabilities.
• LPM flow compensated sampling pump
• True 24-hour battery capacity or continuous A/C power
operation
• Audible alarm siren
• Graphical colour display
• USB, ethernet, removable data card and serial DB9
connections
• Wind and 1 other optional sensor
• Optional accessories such as: Solar Power Panel, strobe
light, and inlet heater
Features:
• Immediate display and data storage of lung damaging
aerosols
• Provides both real-time and filter gravimetric data
• Unique aerodynamic particle sizing real-time sensor
and in-line 47mm filter cassette which allows concurrent
gravimetric samplings
• High correlation to EPMA PM-10 methods and TEOM
• Added value survey sampler for saturation monitoring
studies
• Easy to use Data Analysis Software
• Easy to clean optical sensor with self-purging capabilities
• LPKM flow compensated sampling pump
• True 24-hour battery capacity or continuous A/C power
operation
• Audible Alarm Siren
• Optional accessories such as: Solar Power Panel, strobe
light, and inlet heater
Digital Dust Monitor 3443
Features:
• Particle size range: 0.1 to 10µm
• Measuring range: 0.001 to 10 mg/m3
• Data logging up to 100,000 measurements
• USB interface for data transfer
• Compact and light weight unit
• More than 24 hours run time with Li-ion battery
• Capable of analog and digital output
• Useful tripod mount
• Rubber protector and Shoulder strap included
216
Measuring Method Light Scattering Method
Light Source
Laser diode
Measuring Object
Airborne Particle Matter < 10 µm
Measuring Range
0.001 to 10.0 mg/m3
Accuracy
+/- 10% of reading
Data Logging
100,000 data and time
stamped measurements
Output
Digital
USB
Analog
O to 1 V, Pulse, Alarm
Power Supply
6 AA batteries or AC adapter
Dimensions
W 6.4” x H 4.3” x D 2.4” (162 x
109 x 60mm)
Weight 2.9 lbs. (1.3 kg)
www.conceptcontrols.com
Particle & Dust monitors
HAZ-DUST VDM-7500
Piezobalace Dust Monitor 3521 / 3522
Digitally record workplace dust exposure with the HAZ-DUST
VDM-7500 wireless video dust monitoring system. The VDM7500 measures levels of lung damaging particles while
simultaneously overlaying dust concentration information onto
video images. Easily clip the lightweight monitor to a worker’s
belt and the sensor in the breathing zone. Through wireless
communication, all data is displayed in real time on the PC.
Record and obtain specific events that are clearly linked to
worker exposure to airborne contaminants. View, record, and
store streaming video, data points, and graphical profiles of dust
concentrations on a PC with powerful DustComm Pro Software.
Only the VDM-7500 provides you with the integration of video
and particulate dust monitoring technology for a more dynamic
assessment of air contamination and worker exposure — the
components necessary for documentation and control.
Features:
• Data logging ability allows
user to log 500 samples
• Simple cleaning
mechanism for easy
maintenance
• RS232C port available as
standard
• Back-lit display
• Data can be reviewed on-screen, printed or downloaded to
a computer
• Software included for easy data download and processing
• Easy operation requires no special training
Features:
• All-in-one system
• Digital and wireless for unattended monitoring
• Simultaneous real-time workplace video display,
dust readings, and gravimetric collection for any
type of aerosol
• Record-to-disk feature
• True breathing zone measurements of inhalable, thoracic,
or respirable particulate
• Compact and rapidly deployed
Specifications:
Model
Measuring Object
Ordering Information
Description
VDM-7500 Wireless Video Dust Monitoring System
includes wireless particulate monitor†, wireless video
camera, customized portable PC with radio receiver, and
all software and hardware setup packaged in a rolling
carry case with handle
110 - 240 V
Accessories*
Adapter for GS-3 Respirable Cyclone, required when
using GS-3 Cyclone
Inhalable Sampling Head and Adapter, IOM Sampler,
mounts on monitor sensor
Calibration Standard for monitor, for verifying span and
optical sensor performance
Replacement Battery Pack, NiMH
Principle
As an air sample enters the system, it travels through the
impactor, which captures and removes larger particulates from
the sample. Smaller particulates become electrically charged
and deposited on the piezo-crystal. The total mass of the
deposited particulates affects the piezo-crystal’s frequency.
Since the change in frequency is proportional to the mass of the
particulates, the actual weight of the particulates is obtained.
Cat. No.
Impactor
Measuring Range
770-7500
770-313
770-115A
770-140
770-4105
Requires calibration with equipment sold separately, see accessories
* Cleaning Kit accessory available; contact SKC
† Use the VDM-7500 only with the HAZ-DUST Monitor included with the system.
Sampling Flow
Rate
Accuracy
3521
3522
Airborne Particle
Matter < 10 µm
Airborne Particle
Matter < 2.5 µm
10 µm, 4 µm
2.5 µm
0.01 to 10 mg/m3
1L/min
+/- 10% of reading +/- 1 digit (0 to 5 mg/m3)
+/- 20% of reading +/- 1 digit (5 to 10 mg/m3)
Data Logging
500 data and time stamped measurements
Digital Output
RS-232C
Power Supply
Dimensions
Weight (incl. batteries)
www.conceptcontrols.com
AC or Ni-MH battery
H7.0” x D5.9” x W2.7” (180 x 150 x 65mm)
4.4 lbs. (2 kg)
217
AIR QUALITY
Dust Sentry
Portable Aerosol Mobility
Spectrometer (PAMS)
NEW
The Dust Sentry provides real time,
continuous particle measurement of TSP,
PM10, PM2.5 or PM1 with datalogging and
alarm relay outputs. Numerous integrated
options including SMS and/or email
notifications, weather sensors, noise and
mounting equipment make the Dust Sentry
a flexible base system suitable for a wide
range of applications.
Features:
• Real time particle monitoring,
measures and reports data in 1 minute
intervals
• Accurately measures TSP, PM10, PM2.5 or PM1
• On board data storage for up to 15 years of data
• Web-based and GSM data retrieval and alerts
• Gravimetric filter
• Option to integrate weather, wind, temp/RH sensors, and
sirens
• Tough weatherproof enclosure with solar shielding for hot
climates
• Quick installation and relocatable
Specifications:
Model #
DS 10
Measurement
technology
Near forward light scattering nephelometry
Range
Sample
flowrate
Inlet
Alarm
Datalogging
Reference filter
DS 1
0-2000µg/m3
Accuracy
Cut point
DS 25
+/-(2 ug/m3 +5% of reading)
PM 10
PM 2.5
PM 1
2.0 LPM
Heated
2GB SD card (>15 years data storage)
25mm GF filter
Datalogging and configuration software included
Outputs
RS232 & cellular IP Gateway
Mounting
Pole and wall mounting
Wireless
communication
options
Low power RF modem
Meteorological
sensor options
Temperature & RH sensor, Gill WindSonic, Vaisala
WXT520
Environmental
operating
range
-10°C to +45°C; 10 to 95% RH (NC)
Enclosure
Weight
218
PAMS is an electrical mobility
size spectrometer designed for
portable, mobile, or handheld
aerosol sampling applications. It
provides the number-weighted
diameter distribution of aerosols
over the entire submicrometre
range (10 to 863nm) in one scan.
The unit uses a nonradioactive bipolar
aerosol charger to allow easy access to
sampling sites with tight safety regulations. Its
bipolar charger significantly reduces measurement uncertainty
of larger particles in the submicrometre range.
Features:
• Electrical mobility size spectrometer designed for portable,
mobile, or handheld aerosol sampling applications
• Provides number-weighted diameter distribution of
aerosols over the entire submicrometre range (10 to
863nm) in one scan
• Uses a non-radioactive bipolar aerosol charger to allow
easy access to sampling sites with tight safety regulations
• Bipolar charger significantly reduces measurement
uncertainty of larger particles in the submicrometre range
• Can be used in two modes: Single diameter count mode:
to get a total count within a narrow size range, or Size
distribution mode: to get an automated size distribution
measurement over desired size range or size resolution
• Stand-alone, battery-operated instrument; no external
computer needed
• Weighs only 4.5 kg and measures 23 x 23 x 15 cm
Specifications:
Relay and SMS (optional)
Software
Power
requirements
NEW
Measuring Modes
Single size mode (single size concentration)
Scan mode (size distributions)
Size Range
0.2LPM: 14.5 to 863 nm
0.4LPM: 10 to 433 nm
Scan Resolution
0.2LPM: 14 channels
0.4LPM: 27 channels
Scan Time
0.2LPM: 42 sec to minutes for one scan
0.4LPM: 81 sec to minutes for one scan
Concentration Range 0 to 100,000 particles /cm3
Mains (100 to 260VAC) or regulated 12VDC (10W)
Lockable & weatherproof GRP cabinet IP65; 685
x 350 x 300mm (including solar shield armour &
mounting brackets)
Flow Rate
Inlet: 0.7 LPM
Sample: 0.05 LPM
Bipolar Charger
Dual corona charger at 5 μA
Condensing Fluid
Isopropyl alcohol
Display
Colour touchscreen
Dimensions (WHD)
9.1 x 9.1 x 5.9 inch (23 cm x 23 cm x 15 cm)
Weight
9.9 lbs (4.5 kg )
Less than 12kg
www.conceptcontrols.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement