SRP-X700P Manager User Control Panel

Add to my manuals
21 Pages

advertisement

SRP-X700P Manager User Control Panel | Manualzz

2-347-591-11 (1)

SRP-X700P Manager

User Control Panel

Operating Instructions (Control Software Manual Ver. 1.00)

Before using the software, please read this manual and the

Operating Instructions of the Digital Powered Mixer (main unit) thoroughly and retain it for future reference.

SRP-X700P

 2002 Sony Corporation

Table of Contents

Features ........................................................................................................................... 3

Precautions ...................................................................................................................... 3

About This Manual ......................................................................................................... 3

Installation ....................................................................................................................... 3

Installing the Dedicated USB Driver Software .......................................................... 3

Installing the SRP-X700P Manager ........................................................................... 4

Installing the User Control Panel ............................................................................... 4

Uninstalling ..................................................................................................................... 4

Section 1 SRP-X700P Manager .................................................................................... 5

Names and Functions of Controls on Screen ............................................................. 5

Common operation section ........................................................................................ 5

Menu bar ............................................................................................................. 5

Bottom menu bar ................................................................................................. 6

BLOCK Screen .......................................................................................................... 7

INPUT Screen ............................................................................................................ 8

INPUT OVERVIEW Screen ............................................................................... 8

INPUT EQ Screen ............................................................................................. 10

ROUTING Screen .................................................................................................... 11

OUTPUT Screen ...................................................................................................... 12

OUTPUT OVERVIEW Screen ......................................................................... 12

OUTPUT EQ Screen ......................................................................................... 14

REMOTE Screen ..................................................................................................... 15

GROUP FADER Screen .......................................................................................... 18

SCENE Screen ......................................................................................................... 19

Section 2 User Control Panel ...................................................................................... 20

Names and Functions of Controls on Screen ........................................................... 20

Troubleshooting ............................................................................................................ 21

........................................................................................................................................................................................................................................

• Microsoft and Windows are registered trademarks of U.S. Microsoft Corporation in the U.S. and other countries.

2

Features Installation

The CD-ROM supplied with the SRP-X700P contains two applications and the driver software.

By installing the software in a personal computer running

Windows, you can set the parameters of the SRP-X700P and can perform from the PC the basic operations of the SRP-X700P.

Similarly, you can also operate a Sony DVD, VCR or CD/MD that is connected to the SRP-X700P.

SRP-X700P Manager

The SRP-X700P Manager enables you to set all the functions of the SRP-X700P.

You can set all functions of the SRP-X700P including making various settings in accordance with the operating environment and peripheral equipment, can use of a maximum of 20 scene memories, can save the setup files, and so forth.

User Control Panel

From the User Control Panel, you can control the basic operations

(sound volume adjustment, input selection and scene recall) of the

SRP-X700P and also the basic operations (playback, stop, fast forward, rewind, etc.) of other Sony products (DVD, VCR, CD/

MD) connected to the SRP-X700P, all from a personal computer.

Precautions

• The recommended operating environment for using this software is as follows.

Operating systems:

Microsoft Windows 98 Second Edition

Microsoft Windows Millennium Edition

Microsoft Windows 2000 Professional

Microsoft Windows XP Professional *

Microsoft Windows XP Home Edition *

Your computer should be running one of the above operating systems in the default environment as shipped from the factory.

Operation of this software when the OS has been upgraded is not guaranteed.

* Simple switching of desktop and user cannot be implemented.

CPU: Celeron 400 MHz or higher

Memory: 128 MB or more

Hard disk free space: 10 MB or more

• USB terminal should be equipped as standard.

• This software may not operate appropriately depending on the

USB equipment and hub used simultaneously by your computer.

Be sure to use the USB equipment and hub conforming to the

USB 2.0 standard.

• Operation this software is not guaranteed in every personal computer, even if the recommended environment is satisfied.

• Use the USB cable conforming to USB 2.0 to connect to the

SRP-X700P. If any cable other than the USB cable conforming to USB 2.0 is used, the software may not work properly.

• The specifications of this software are subject to change without notice due to improvement.

• The actual screens of the application software may appear differently from those printed in these Operating Instructions.

About This Manual

This manual describes operations of the SRP-X700P when it is used via a personal computer.

Section 1 describes how to set the parameters using the SRP-

X700P Manager. Section 2 describes how to operate the SRP-

X700P from the User Control Panel and Sony products connected to the SRP-X700P. Read this manual together with the Operating

Instructions of the respective Sony products.

The dedicated USB driver software is necessary to connect the SRP-X700P Manager and User Control

Panel to the SRP-X700P.

Installing the Dedicated USB

Driver Software

• The dedicated USB driver software is contained in the CD-ROM supplied with the SRP-X700P.

• Install the dedicated USB driver software by following the instructions shown on the screen. Some computer may reboot when the dedicated USB driver software is installed.

1

Turn on the main power of the personal computer and start

Windows.

2

Insert the supplied CD-ROM into the CD-ROM drive of the personal computer.

3

Turn on the main power of the SRP-X700P. Connect the connector on the front or rear of the SRP-X700P to the USB connector of the personal computer using a USB cable.

4

The USB device of the SRP-X700P is recognized and the dialog box [This wizard searches for new drivers for:] appears.

Click [Next >].

5

Select [Search for the best driver for your device.

(Recommended).] and click [Next >]. (Fig. 1)

Click

Fig. 1

6

Click on the check box [Specify a location:] and click

[Browse...]. Specify [Driver] folder of the supplied CD-ROM and click [Next >]. (Fig. 2)

Click

Fig. 2

7

When the screen [Windows driver file search for the device:] appears, click [Next >].

8

When the screen [Windows has finished installing the software that your new hardware device requires.] appears, click [Finish].

9

Because the USB port of the SRP-X700P is recognized as

[Unknown Device], click [Next >].

0

Select [Search for the best driver for your device.

(Recommended).] and click [Next >]. (Fig. 3)

Fig. 3

Select

Click on the check box

Select

Click

3

4 qa

Click on the check box [Specify a location:] and click

[Browse...]. Specify [Driver] folder of the supplied CD-ROM and click [Next >]. (Fig. 4)

Click on the check box

Click

Fig. 4 qs

When the screen [Windows driver file search for the device:] appears, click [Next >].

qd

When the screen [Windows has finished installing the software that your new hardware device requires.] appears, click [Finish].

Installation of the dedicated USB driver software is now complete.

Installing the User Control Panel

1

Insert the supplied CD-ROM into the CD-ROM drive of the personal computer.

Open the SRP-X700P Control folder.

Double-click the Setup icon.

2

The User Control Panel installation screen appears.

3

When the screen [Welcome to the User Control Panel installation program] appears, click OK.

4

When the screen [Begin the installation by clicking on the button below] appears, click the Setup icon on the top left of the screen. (Fig. 2)

Installing the SRP-X700P Manager

1

Insert the supplied CD-ROM into the CD-ROM drive of the personal computer.

Open the SRP-X700P Manager folder.

Double-click the Setup icon.

2

The SRP-X700P Manager installation screen appears.

3

When the screen [Welcome to the SRP-X700P Manager installation program] appears, click OK.

4

When the screen [Begin the installation by clicking in the button below] appears, click the Setup icon on the top left of the screen. (Fig. 1)

Fig. 2

The SRP-X700P Control folder is created in C:\Program Files.

To change the installation destination, click Change Directory on the bottom right of the screen.

5

When the screen [Setup will add items to the group shown in the Program Group box. You can enter a new group name or select one from the Existing Groups LIST] appears, click

Continue on the bottom left of the screen.

6

When the screen [User Control Panel Setup was completed successfully] appears, click OK.

Installation of the User Control Panel is now completed.

Fig. 1

The SRP-X700P Manager folder is created in C:\Program

Files. To change the installation destination, click Change

Directory on the bottom right of the screen.

5

When the screen [Setup will add items to the group shown in the Program Group box. You can enter a new group name or select one from the Existing Groups LIST] appears, click

Continue on the bottom left of the screen.

6

When the screen [SRP-X700P Manager Setup was completed successfully] appears, click OK.

Installation of the SRP-X700P Manager is now complete.

Uninstalling

1

Click the Start menu and select [Settings (S)]. Then click the

[Control Panel] to open it.

2

Double-click the [Add/Remove Programs] icon and select the application “SRP-X700P Manager” or “User Control Panel” and the driver software “SRP-X700P USB Driver” that you want to delete from the list of the [Install/Uninstall] tab.

3

Click [Add/Remove (R)...].

This completes the uninstallation.

Note

When using Microsoft Windows 2000 Professional, Microsoft

Windows XP Professional or Microsoft Windows XP Home

Edition, be sure to log on as the user having administrator authority, then perform the installation or uninstallation.

Section 1 SRP-X700P Manager

The SRP-X700P Manager enables you to set all parameters of the SRP-X700P.

Starting the SRP-X700P Manager

If the SRP-X700P Manager is started after connecting the SRP-X700P to the personal computer with a USB cable, the present setup of the

SRP-X700P is read.

If the SRP-X700P Manager is started before connecting the SRP-X700P to the personal computer, the default setup of the SRP-X700P when shipped from the factory is read.

If the SRP-X700P Manager is started by double-clicking the existing setup file (*.x7p), the status stored in the existing setup file is sent to the

SRP-X700P.

The screen images that are used in this manual are all default settings when shipped from the factory.

Names and Functions of Controls on Screen

Common operation section

The controls shown below appear on all the screens.

1

3

4

5

2

1 Menu bar

The titles of the menu are displayed.

You can perform operations that are common to the basic settings and each setup screen.

File menu

This software allows you to save the parameters of up to 20 scenes and the information in a single setup file (*.x7p).

New: Creates a new setup file.

The new setup file contains the default settings when shipped from the factory.

Open: Opens an existing setup file.

Open Scene: Opens the specified scene number from the 20 scenes in the existing setup file.

2

1

5

3

4

• Specify a setup file. 1

• The information that is set in the specified setup file is displayed. 2

• Specify the scene number. 3

• The index of the specified scene number is displayed. 4

• Click the Open button. 5

Save: Saves the new data by overwriting the existing data.

Save As: Saves the data under a different name.

Exit: Exits the SRP-X700P Manager.

5

6

Names and Functions of Controls on Screen

Edit menu (Displayed only on the INPUT and

OUTPUT screens)

Copy: Copies the parameters.

2 Bottom menu bar

You can select the setup screen for each parameter.

For the INPUT and OUTPUT buttons, submenus are displayed.

1

3

2

You can copy the parameters of the desired channel to the specified channel. Use this function when you want to use multiple channels with the same setup. However, you cannot copy the parameters of index, TRIM (INPUT), feedback reducer (INPUT) and REF

LEVEL (OUTPUT).

• Select the copy source channel. 1

• Click the check box of the copy destination channel. 2

• Press OK. 3

Communication menu

• Disconnect: Disconnects communication with the SRP-X700P.

• Connect: You can select the connection method on the dialog box.

Download: Sends the parameters of the SRP-X700P to

SRP-X700P Manager.

Upload: Sends the parameters that are set by using

SRP-X700P Manager to the SRP-X700P.

Options menu

• Password Setting: You can set a password.

How to set a password

The [Password Setup] dialog box appears. Enter the password in the Password field. For confirmation, enter the same password again in the [Confirm password] field and click OK.

The password can be up to 8 alphanumeric characters.

Note

If you forget the password, you cannot start the system next time, so take a note of the password and keep it safely. If you forget the password, uninstall the SRP-X700P Manager and then reinstall it.

• Factory Preset: Resets all parameters to the default settings.

Note

Be careful that the system cannot be returned to your own settings after resetting it to the default settings.

Help menu

• About: You can confirm information about the version.

3 FRONT PANEL LOCK button

You can lock the FRONT PANEL so that the buttons and faders on the SRP-X700P front panel are disabled to prevent accidental operation. When locked, the FRONT PANEL

LOCK button lights in red, and the LOCK indicator on the front of the SRP-X700P also lights in red.

4 CONNECTION indicator

The CONNECTION indicator lights in green while communication with the SRP-X700P is in progress.

5 RETURN button

You can return to the previous screen that was selected immediately before.

1.1 BLOCK Screen

The BLOCK screen displays the setup status and the signal level according to the internal blocks in the SRP-X700P.

If you click a button, the screen jumps to the related setup screen. You can select ON/OFF and set parameters on each screen.

3 4 56 7 8 9 qa qd qfqg qh qj qk

2 w;

1

0

1 INPUT index

You can enter an index of each input channel. By entering the name of the connected equipment as the index, you can easily check the signal system when setting the parameters. You can enter up to 8 alphanumeric characters.

2 TRIM button

The reference level of each input channel that is set on the

INPUT OVERVIEW screen appears on the TRIM buttons.

3 Input level meter

Displays the input signal level of each input channel.

4 LCF (Low-Cut Filter) button

When you turn on the LCF button, it lights in green.

5 PEQ (Parametric EQualizer) button

When you turn on the PEQ button, it lights in green.

6 FR (Feedback Reducer) button

When you turn on the FR button, it lights in green.

7 COMP (Compressor) button

When you turn on the COMP button, it lights in green.

8 INPUT fader display

Displays the setup value of the INPUT fader.

9 INPUT MUTING button

The INPUT MUTING button lights in red when muted.

0 INPUT VIDEO TYPE display

Displays the video input signal format of A to F of LINE4.

qa Setup.. button

The screen jumps to the ROUTING screen when this button is pressed.

ws wa qs ql qs AUTOMATIC MIXER button

The AUTOMATIC MIXER button lights in green while the

AUTOMATIC MIXER is in operation.

qd OUTPUT MUTING button

The OUTPUT MUTING button lights in red when muted.

qf OUTPUT fader display

Displays the setup value of the OUTPUT fader.

qg EQ (EQualizer) button

When you turn on the EQ button, it lights in green.

qh DELAY button

When you turn on the DELAY button, it lights in green.

qj Output level meter

Displays the output signal level of each output channel.

qk REF LEVEL button

Displays the reference level of each output channel on the button that is set on the OUTPUT OVERVIEW screen.

ql ATT (ATTenuator) button

Displays the output ATT level to the internal power amplifier.

w; OUTPUT index

You can enter an index of each output channel. You can enter up to 8 alphanumeric characters.

wa CLIP indicator

The CLIP indicator lights in red when the internal power amplifier starts clipping. Adjust the output level using wf ATT so that the CLIP indicator does not turn on frequently.

ws PROTECTION indicator

The PROTECTION indicator lights in red when the power amplifier protection circuit operates.

7

Names and Functions of Controls on Screen

1.2 INPUT Screen

You can set parameters of the input block of the SRP-X700P from the INPUT screen.

1.2.1 INPUT OVERVIEW Screen

This screen corresponds to the input module of the audio mixer. This screen enables you to set the following.

4 5 qh

1

2

8

9 qa qf qd qg

3

6

7 q; qs qj qk

1 INPUT index

Displays the index that is input on the BLOCK screen.

2 INPUT level meter

Displays the input signal level after the TRIM adjustment is complete with the VU response.

3 +48 V indicator

The +48 V indicator lights in red when the +48 V button on the rear of the SRP-X700P is turned on.

4 RF indicator

The RF indicator lights in green when the wireless tuner unit installed in the SRP-X700P receives the RF signal. As long as this indicator is on, this system selects the wireless tuner signal.

5 LINE indicator

The LINE indicator lights in green when the MIC/LINE select button on the rear of the SRP-X700P is set to the LINE position.

6 TRIM controls

The TRIM controls enable you to adjust the reference input level of each input channel.

Each click of the [+] or [--] button increments or decrements the reference input level by 1 dB. The adjustment range of MIC1/

WL1, MIC2/WL2, MIC3 and MIC4 is –60 dBu to –45 dBu. The adjustment range of LINE3 and LINE4 is –10 dBu to 0 dBu.

The adjustment range of MIC5/LINE1 and MIC6/LINE2 is

–60 dBu to –45 dBu when MIC is selected or –10 dBu to +5 dBu when LINE is selected. You can also enter numerical values directly.

It is recommended to adjust the TRIM controls so that 0 VU of the INPUT level meter lights often.

8

7 Setup.. button

By clicking the Setup button, the display jumps to the INPUT

EQ screen where you can set the low-cut filter, feedback reducer and parametric equalizer.

8 LCF (Low-Cut Filter) button

Each press of this button toggles the low-cut filter between on and off. This button lights in green when pressed on. The LCF removes low-frequency components such as blowing noise and makes the sound clear.

9 PEQ (Parametric Equalizer) button

Each press of this button toggles the parametric equalizer between on and off. This button lights in green when pressed on. To set the PEQ, click on the 7 Setup.. button.

0 FR (Feedback Reducer) button

Each press of this button toggles the feedback reducer that is set on the INPUT EQ screen between on and off. This button lights in green when pressed on. To set the FR, click on the

7 Setup.. button.

qa COMP (Compressor) setup box

This function compresses the dynamic range of the input signal that affects the unity sound volume. The compressor can be set in three steps of SOFT, MID or HARD.

When the AUTOMATIC MIXER is turned ON, the compressor is set automatically and the manual COMP setup is disabled.

qs MUTING button

Pressing this button mutes the input signal of each channel.

The MUTING button lights in red when muted.

qd GAIN LIMIT and qf OVER GAIN indicators

The sending level from input section is the sum of the qj INPUT fader and the input fader of the SRP-X700P.

If the SRP-X700P master volume is manipulated and the sound volume is remotely controlled via the REMOTE terminal using the GROUP FADER screen and REMOTE screen respectively, these setup values are also added to the sum.

You can set the upper limit of the sending level by the qd GAIN LIMIT to prevent excessive output level using multiple volume controls. Each click of the [+] or [--] button increments or decrements the sending level by 1 dB in the range of +10 dB to –10 dB. You can enter numerical values directly on the screen.

If the sending level exceeds the GAIN LIMIT value, the actual sending level is limited to the GAIN LIMIT value and the qf OVER GAIN indicator lights in red.

qg

indicator

If there is no sending sound when muted or when the INPUT fader is at the –

∞ level position, the –∞ indicator lights in yellow.

qh FADER select and qj INPUT fader

The qj INPUT fader has the two modes of ACTIVE and

INACTIVE.

To switch the fader mode, click the qh FADER select. The selected mode lights in yellow. The yellow marker displayed on the side of the fader indicates the fader position, which is the sum of the qj INPUT fader setup and the SRP-X700P input fader setup.

When the sound volume of a specific input channel is to be set from the REMOTE screen and the GROUP FADER screen, the fader position determined by the SRP-X700P Master volume control and the remote control signal via the

REMOTE terminal is indicated.

ACTIVE mode:

You can operate the qj INPUT fader by dragging the fader portion. In the ACTIVE mode the sound volume is determined by the qj INPUT fader; the SRP-X700P fader, the MASTER volume control and the remote control via the REMOTE terminal have no effect.

INACTIVE mode:

The sound volume is indicated by the yellow marker on the side of the fader. The SRP-X700P fader, the MASTER volume control and the remote control via the REMOTE terminal determine the sound volume.

The qj INPUT fader has no effect on the sound volume.

Note

• A sudden large sound may occur when you switch to

ACTIVE mode while the sound volume is reduced by either the fader, MASTER volume or from the REMOTE terminal.

Before switching the mode, stop the connected equipments and check the direction of the microphones.

• The mode of the INPUT fader and the mode of the OUTPUT fader are interlocked and so are switched together.

qk LINE4 input select button

LINE4 has the six input channel terminals of A to F.

You can select a input channel from the six channels using this button. The selected button lights in green.

9

Names and Functions of Controls on Screen

1.2.2 INPUT EQ Screen

You can set the low-cut filter, feedback reducer and parametric equalizer of the SRP-X700P input block from the INPUT EQ screen.

1

2

3

4

5

6

7

8

9

0

1 Channel select button

Selects the INPUT channel that you want to set.

The selected button lights in yellow.

2 INPUT index

Displays the index that is input on the BLOCK screen.

3 Frequency response graph

Displays the overall frequency response characteristics of the low-cut filter, parametric equalizer and feedback reducer.

Low-Cut Filter Block

4 LCF (Low-Cut Filter) button (100 Hz and –12 dB/oct)

Turns on and off the low-cut filter.

It lights in green when the LCF button is pressed ON.

Feedback Reducer Block

The feedback reducer suppress the positive acoustic feedback by detecting the frequency that causes howling in advance and by reducing the gain of the frequency.

5 FR (Feedback Reducer) button

Suppresses howling at the frequency that is detected when pressing the 6 Setup button.

It lights in green when the FR button is pressed ON.

6 SETUP button

Detect the howling point as follows.

• Clicking the SETUP button displays the Channel Select dialog box.

• Select the channel that you want to detect.

• When OK button is pressed, the detecting is started.

• When the detection is complete, the feedback reducer is turned on.

Note

Set the microphones in ordinary position before starting.

Parametric Equalizer Block

The MIC1/WL1, MIC2/WL2, MIC3, MIC4, MIC5/LINE1 and

MIC6/LINE2 channels have a 3-band parametric equalizer, and the

LINE3 and LINE4 channels have a 2-band parametric equalizer.

Clicking the v or V button changes the following parameters of each band. You can also enter numerical values directly. You can change the center frequency and the GAIN by dragging the marker portion with the mouse. Q can be entered on the Q setup box.

Right-clicking the marker portion returns the GAIN to 0 dB.

7 PEQ (Parametric EQualizer) button

Turns on and off the parametric equalizer. When the PEQ button is turned on, it lights in green.

8 Frequency setup box

Set the frequency in 1/3-octave steps in the ranges of 25 Hz to

100 Hz and 14 Hz to 20 kHz. Set it in 1/12-octave steps in the range of 100 Hz to 14 kHz.

9 Q setup box

Set Q in the range of 0.15 to 22.

0 GAIN setup box

Set GAIN in 0.5-dB steps in the range of –15 dB to +15 dB.

10

1.3 ROUTING Screen

On this screen, you can set to which output channel the input signal is to be output.

4

1

3

2

1 INPUT index

Displays the INPUT channel index that is entered on the

BLOCK screen.

2 OUTPUT index

Displays the OUTPUT channel index that is entered on the

BLOCK screen.

3 ASSIGN button

You can select the signal input and output path. Right-clicking the button displays the menu. You can select the desired sending level from –20 dB, –15 dB, –12 dB, –9 dB, –6 dB,

–3 dB or 0 dB. The ASSIGN button lights in green when pressed ON at 0 dB. This button lights in blue purple when pressed ON at any level between –20 dB and –3 dB.

z

Moving the pointer to the button displays the present output level.

4 AUTOMATIC MIXER button

Turns on and off the AUTOMATIC MIXER.

The AUTOMATIC MIXER button lights in green when the

AUTOMATIC MIXER button is pressed ON.

When it is pressed ON, the compressor of the INPUT screen is set at the same time.

The AUTOMATIC MIXER contains two functions, the compressor function and the gate function.

If the total output sound volume exceeds a certain level such as when many people talk loudly or at the same time, the compressor function limits the output sound volume so that it does not exceed the upper-specified level. (See part 1 in the figure.)

If the microphone input sound falls below a lower-specified level, the gate function cuts off the microphone sound so that the background noise is reduced, howling is prevented, and clear sound quality is maintained. When larger than a certain volume is input again, the microphone input is turned on without delay. (See part 2 in the figure.)

Conventional automatic mixers have an inherent lack of sound at the beginning of a speech due to the time difference after the audio input level is detected until the gate starts working.

The SRP-X700P solves this problem by removing the time difference by using digital signal processing.

Output level

0

2

1

Input level

11

Names and Functions of Controls on Screen

1.4 OUTPUT Screen

You can set the parameters of the output block of the SRP-X700P from the OUTPUT screen.

1.4.1 OUTPUT OVERVIEW Screen

This screen corresponds to the output module of the audio mixer. This screen enables you to set the following.

The OUTPUT 1 through OUTPUT 8 correspond to the LINE OUTPUT 1 through LINE OUTPUT 8 of the main unit.

wa 9 w; qf qj qh qk ws wd

1

2 ql

3 wh wf wg

5

7

0 qs qa qd

4

6

8 qg

1 OUTPUT index

Displays the index that is input on the BLOCK screen.

2 OUTPUT level meter

Displays the output signal level by the VU response.

3 REF LEVEL selection box

You can set the reference output level for each output channel.

You can set it to –10, –5, 0 or +4 dBu for OUTPUTs 1 and 2.

You can set it to –10, –5 or 0 dBu for OUTPUTs 3 to 8.

4 Setup.. button

By clicking the Setup button, the display jumps to the

OUTPUT EQ screen where you can set the various equalization functions as shown below.

5 EQ (EQualizer) button

Turns on and off the equalizer.

The EQ (EQualizer) button lights in green when the EQ button is pressed ON.

6 HCF (High-cut Filter) indicator

The HCF indicator lights in green when the high-cut filter is pressed ON.

7 DELAY button

Turns on and off the delay function.

The DELAY button lights in green when the delay is pressed

ON.

8 DELAY value setup box

You can set the delay time value from this setup box. Clicking the v or V button allows you to set the DELAY value in

2.9-ms steps in the range of 0ms to 150.8 ms. Alternatively, you can set DELAY in 1-m steps in the distance range of 0m

12 to 52 m, or in 3.33-ft steps in the range of 0 ft to 173.3 ft. You can also enter numerical values directly in the setup box. To switch the units, use the 9 DELAY UNITS setup box.

9 DELAY UNITS setup box

The DELAY UNITS setup box allows you to select the unit of the delay as shown below. Clicking the DELAY UNITS setup box indicates the units. Select the desired unit.

• In units of time: ms

• In units of distance: meter, feet

0 MUTING button

Mutes the output signals of the respective channels. The

MUTING button lights in red when muted.

qa GAIN LIMIT and qs OVER GAIN indicator

The output level of the output channel is the sum of the SRP-

X700P master volume on the GROUP FADER screen and the remote control via the remote terminal on the REMOTE screen.

You can set the upper limit of the output level by the qa GAIN LIMIT to prevent excessive output level caused by using multiple volume controls. Each click of the [+] or [--] button increments or decrements the output level by 1 dB in the range of +10 dB to –10 dB. You can enter numerical values directly on the screen.

If the output level exceeds the GAIN LIMIT value, the actual output level is limited to the GAIN LIMIT value and the qs OVER GAIN indicator lights in red.

qd

indicator

If there is no output sound when muted or when the OUTPUT fader is at the –

∞ level position, the –∞ indicator lights in yellow.

qf FADER select and qg OUTPUT fader

The qg OUTPUT fader has the two modes of ACTIVE and

INACTIVE.

To switch the fader mode, click the qf FADER select. The selected mode lights in yellow. The yellow marker displayed on the side of the fader indicates the fader position that is the addition of the qg OUTPUT fader setup.

When the sound volume of a specific input channel is to be set from the REMOTE screen and the GROUP FADER screen, the fader position determined by the SRP-X700P Master volume control and the remote control signal via the

REMOTE terminal is indicated.

ACTIVE mode:

You can operate the qg OUTPUT fader by dragging the fader portion. In the ACTIVE mode, the sound volume is determined by the qg OUTPUT fader; the SRP-X700P fader, the MASTER volume control and the remote control via the

REMOTE terminal have no effect.

INACTIVE mode:

The output sound volume is indicated by the yellow marker on the side of the fader. The SRP-X700P fader, the MASTER volume control and the remote control via the REMOTE terminal determine the output sound volume.

The qg OUTPUT fader has no effect on the output sound volume.

Note

• A sudden large sound may occur when you switch to

ACTIVE mode while the sound volume is reduced by either the fader, MASTER volume or from the REMOTE terminal.

Before switching the mode, stop the connected equipments and check the direction of the microphones.

• The mode of the INPUT fader and the mode of the OUTPUT fader are interlocked and so are switched together.

qh REC OUT index

Displays the index that is entered on the BLOCK screen.

qj REC OUT level meter

Displays the output signal level using the VU response.

qk REC OUT REF LEVEL selection box

You can set the reference output level for every output channel on this selection box.

You can select –10, –5 or 0 dBu as the REC OUT level.

ql REC OUT MUTING button

Mutes output signals of the respective channels. The REC

OUT MUTING button lights in red when muted.

Power Amplifier Block

w; Operation mode setup box

Selects one of the following modes depending on the type of speaker to be connected.

Lo Imp.: A low impedance (4

Ω to 16 Ω) speaker is to be connected.

70 V LINE: A high impedance (32

Ω to 10 kΩ) speaker is to be connected.

In the case of 70 V LINE, the channel 1 setup becomes valid for the selectors and attenuators.

wa PROTECTION indicator

The PROTECTION indicator lights in red when the internal power amplifier protection circuit operates.

Note

When the PROTECTION indicator lights

The protection circuit operates (PROTECTION indicator lights) and the speaker and amplifier are protected from damage by decreasing or cutting the output signal in case of the following:

• If the temperature of the heat sink inside the amplifier exceeds the specified value.

The connected speaker impedance is too low.

Air intake and air exhaust holes (on the right and left sides of the SRP-X700P) are choked by dust.

• The SPEAKER terminal is short-circuited.

In such a case, turn the POWER switch to the OFF position and remove the cause of the fault before using the unit again.

• If DC voltage appears in the SPEAKER terminal due to failure.

Turn off the POWER switch and contact your Sony representative where you purchased the unit or contact your local Sony Sales office or Dealer.

ws SPEAKER OUTPUT index

Displays the index that is entered on the BLOCK screen.

wd SELECT setup box

Selects the input signal to the internal power amplifier. When the 70V LINE is selected, the channel 1 setup only is valid.

wf ATT

Adjusts the output level for the internal power amplifier.

Clicking the [+] or [--] button increases or decreases the output level in the range of 0dB to –

∞ dB. When the 70 V LINE is selected, you can adjust channel 1 only. ATT is set at the

–10 dB position for ordinary use.

wg SPEAKER OUTPUT MUTING button

Mutes the speaker output. The SPEAKER OUTPUT

MUTING button lights in red when muted. When the 70V

LINE is selected, the channel 1 only can be operated.

wh CLIP indicator

The CLIP indicator lights in red when the internal power amplifier clips. Adjust the output level using wf ATT so that the CLIP indicator does not light frequently.

13

Names and Functions of Controls on Screen

1.4.2 OUTPUT EQ Screen

You can set the equalizer of the SRP-X700P output block from the OUTPUT EQ screen.

1

2

3

4

5

6

7

5

6

7

5

6

7

8

1 Channel select button

Selects the OUTPUT channel that you want to set.

The selected button lights in yellow.

2 OUTPUT index

Displays the index that is entered on the BLOCK screen.

3 Frequency response graph

Displays the overall frequency response characteristics of the high-cut filter and parametric equalizer.

Equalizer Block

The OUTPUT 1 and OUTPUT 2 channels have an 11-band parametric equalizer. The OUTPUT 3 to OUTPUT 8 channels have a 4-band parametric equalizer. Clicking the v or V button changes the following parameters of each band. You can also enter numerical values directly. You can change the center frequency and the GAIN by dragging the marker with the mouse. Q can be entered on the Q setup box. Right-clicking the marker portion returns the GAIN to 0dB.

4 EQ (EQualizer) button

Turns on and off the equalizer. When the EQ button is turned on, it lights in green.

5 Frequency setup box

Set the frequency in 1/3-octave steps in the frequency ranges of 25 Hz to 100 Hz and 14 Hz to 20 kHz. Set it in 1/12-octave steps in the range of 100 Hz to 14 kHz.

6 Q setup box

Set Q in the range of 0.15 to 22.

7 GAIN setup box

Set GAIN in 0.5-dB steps in the range of –15 dB to +15 dB.

8 HCF (High-cut Filter) button

This button allows you to turn on and off the 90 Hz high-cut filter. Use the HCF function when you connect a sub woofer to an output as a loud speaker. When the HCF is turned on, it lights in green and the parametric equalizer band decreases by one. (Applications that play only 5.1 channel audio signals such as DVD, do not require the HCF.)

14

1.5 REMOTE Screen

You can establish various setups of the remote terminal from the REMOTE screen.

6

5

1

2

3

4 qa

0 qs qd

8 9 7

PARALLEL I/O Block

1 PARALLEL INPUT indicator

Displays the status of the parallel input terminal.

The PARALLEL INPUT indicator lights when the parallel input terminal is ON (0.8V or less).

Refer to the Operating Instructions of the SRP-X700P for the specifications.

2 PARALLEL INPUT FUNCTION setup box

You can set the functions of each input channel.

For the setting procedure, refer to “PARALLEL I/O Parameter

Setup” on the next page.

3 PARALLEL OUTPUT button

Displays the status of the parallel output terminal.

The PARALLEL OUTPUT button lights in green when the parallel output terminal is ON.

Pressing this button enables you to perform the operation test of the equipment connected to the parallel output terminal.

4 PARALLEL OUTPUT FUNCTION setup box

You can set the functions of each output channel.

For the setting procedure, refer to “Setting Parameters of

PARALLEL I/O” on the next page.

MACHINE CONTROL Block

You can establish various setups to control Sony products through the Control-S output terminal. For details of the connection and other procedures, refer to “How to Control AV Equipment from the

SRP-X700P” of the SRP-X700P Operating Instruction.

5 MACHINE TYPE setup box

Selects the type of machines to be connected to LINE3,

LINE4A to LINE4F. The machine types that can be controlled by Control-S appear. Select the machine type for the machine to be connected.

6 CTRL S OUTPUT CH setup box

Selects the channel of the Control-S output terminal to be connected to the machines of LINE3, LINE4A to LINE4F.

7 CONNECTION TYPE setup box

Selects the connection type for each channel of the

6 Control-S output terminal.

• Wired: To connect machines having the Control-S input terminal

• IR: To connect a supplied IR transmitter to control the

Sony’s AV equipment without the Control-S input terminal

8 TEST machine selector box and 9 CONTROL

buttons

Select the terminal to which the machine to be tested is connected, from the 8 TEST machine selector box. Select the desired test command by pressing any of the 9

CONTROL buttons. You can send the PREV. (previous track),

NEXT (next track), STOP (stop), REW. (rewind), PLAY

(playback), F.F. (fast forward) or PAUSE (pause) commands.

15

Names and Functions of Controls on Screen

PROJECTOR CONTROL Block

You can establish various setups to control a projector, refer to

“How to Control the Display from the SRP-X700P” of the SRP-

X700P Operating Instruction.

q; I/F TYPE

The connection method that corresponds to the projector selected by qa PROJECTOR PROTOCOL setup box, is displayed.

qa PROJECTOR PROTOCOL setup box

Select a projector to be connected.

qs REMOTE POWER ENABLE button

You can interlock the power on/off control of the projector with the POWER button of the SRP-X700P. The REMOTE

POWER ENABLE button lights in green when interlocked.

qd SIGNAL DEFINE setup box

Select the video signal format for each channel of the LINE 4 input, that is sent to projector.

• LINE4A to LINE4C: You can select VIDEO, S-VIDEO or

LAN.

• LINE4D to LINE4F: You can select RGB, COMPONENT or LAN.

When you select LAN, the LAN input connector of a projector is automatically selected.

Note

• When you connect a projector with the Control S, you cannot mix the RGB signal with the COMPONENT signal.

• When you select LAN, select an appropriate projector supporting LAN from “How to Control the Display from the

SRP-X700P” of the SRP-X700P Operating Instruction.

Setting Parameters of PARALLEL I/O

Procedure for setting FUNCTION on the REMOTE screen

Example: The procedure for setting the LINE4 input to “A” when PARALLEL INPUT 1 is set to ON:

<Setting FUNCTION> <Setting parameter>

Completed.

Click the PARALLEL

INPUT FUNCTION setup box.

Click the dropdown list to display parameters.

Select the desired

FUNCTION.

Select a parameter.

* For the contents of each item, perform the same step referring to the table shown on page 17.

16

Parameters in the PARALLEL INPUT FUNCTION setup box

Function

NONE: Does not set any function.

AV SEL: Selects the LINE4 input.

LVL+: Increases the sound volume with an external switch.

LVL–: Decreases the sound volume with an external switch.

LVL: Adjusts the sound volume with an external sound volume controller.

Muting: Performs muting.

RECALL: Recalls the desired scene No.

LINE3 Control: Controls the device connected to LINE3.

LINE4 Control: Controls the device connected to LINE4.

Parameter

—————

A: Selects A.

to

F: Selects F.

OFF: Enters the off state.

Mic1: Selects Mic1.

to

Mic4: Selects Mic4.

Mic5Line1: Selects Mic5/Line1.

Mic6Line2: Selects Mic6/Line2.

Line3: Selects Line3.

Line4: Selects Line4.

Out1: Selects output channel 1.

to

Out8: Selects output channel 8.

MasterA: Selects Master A.

MasterB: Selects Master B.

Remote1: Selects Remote1.

to

Remote6: Selects Remote6.

1: Recalls scene No. 1.

to

20: Recalls scene No. 20.

Play: Starts playback.

Pause: Pauses or restarts playback or recording.

Stop: Stops playback or recording.

FF: Starts playback in fast forward.

Rew: Starts playback in rewind.

Rec: Starts recording.

Next: Moves to the next track.

Prev: Returns to the previous track.

On: Turns on the power.

Standby: Sets the power in the standby state.

PJ Power: Controls the projector power.

(Turn on the projector power when the parallel input terminal is set to ON. Set the projector power to standby when the parallel input terminal is set to OFF.)

—————

Parameters in the PARALLEL OUTPUT FUNCTION setup box

Function

NONE: Does not set any function.

AV SEL: Outputs the tally signal when LINE4 input is selected.

∞: Outputs the tally signal when the –∞ indicator lights.

Over: Outputs the tally signal when the Over indicator lights.

RECALL: Outputs the tally signal when the desired scene No. is recalled.

PJ Power: Outputs the tally signal when the projector power is controlled.

Parameter

—————

A: Selects A.

to

F: Selects F.

OFF: Enters the off state.

Mic1: Selects Mic1.

to

Mic4: Selects Mic4.

Mic5Line1: Selects Mic5/Line1.

Mic6Line2: Selects Mic6/Line 2.

Line3: Selects Line3.

Line4: Selects Line4.

Out1: Selects output channel 1.

to

Out8: Selects output channel 8.

MasterA: Selects MasterA.

MasterB: Selects MasterB.

1: Recalls scene No. 1.

to

20: Recalls scene No. 20.

On: Turns on the power.

Standby: Sets the power in the standby state.

17

Names and Functions of Controls on Screen

1.6 GROUP FADER Screen

You can group several faders in order to move multiple internal faders from the Remote terminal or from the Master volume control of the SRP-X700P.

1

2

3

4

5

1 FADER GROUP index

Enters the index of the FADER GROUP. You can enter up to 8 alphanumeric characters.

2 INPUT index

Displays the INPUT index that is entered on the BLOCK screen.

3 OUTPUT index

Displays the OUTPUT index that is entered on the BLOCK screen.

4 FADER select button

Selects the faders that you want to move at a time.

The selected buttons light in green.

Note

Mixed use of the INPUT fader and OUTPUT fader in the same group is not possible.

5 MUTING button

Mutes for every FADER GROUP.

The MUTING button lights in red when muted.

18

1.7 SCENE Screen

You can set scenes from this screen.

You can store the setups on each screen of INPUT, ROUTING, OUTPUT and GROUP FADER into the internal memory of the SRP-X700P or call them from the scene memory.

1 2 3 5

7

6

8

4

9

SCENE block

You can recall, store or clear the scenes.

To recall the scene that is set

• Select the scene No. that you want to recall, using the

1 SCENE No. button.

• Click the 2 RECALL button.

To memorize the parameter that is set

• Select the scene No. that you want to memorize, using the

1 SCENE No. button.

• Enter the 3 SCENE index. You can enter up to 8 alphanumeric characters.

• Select the function that you want to memorize, from the

4 FUNCTION area.

When recalling the scene, only the function that is selected here is recalled.

• ALL FUNCTIONS button

Select all functions.

• INPUT FUNCTION button

Memorizes all functions of the INPUT screen except the

MUTING button, INPUT fader and LINE4 select button.

• INPUT MUTING button

Memorizes the MUTING button state of the INPUT screen.

• INPUT FADER button

Memorizes the INPUT FADER.

• AV SELECTOR button

Memorizes the LINE4 select button state.

• ROUTING button

Memorizes the ASSIGN button state of the ROUTING screen.

• OUTPUT FUNCTION button

Memorizes all functions of the OUTPUT screen except the

MUTING button and OUTPUT fader button.

• OUTPUT MUTING button

Memorizes the MUTING button state of the OUTPUT screen.

• OUTPUT FADER button

Memorizes the OUTPUT fader.

• GROUP MUTING button

Memorizes the MUTING button state of the GROUP FADER screen.

• GROUP FADER button

Memorizes the fader selector button state of the GROUP

FADER screen.

• Click the 5 STORE button.

Clearing the setup scene

• Select the scene No. that is to be cleared using the 1 SCENE

No. button.

• Click the 6 CLEAR button.

7 FRONT PANEL SCENE RECALL

You can assign the scene numbers (1 to 20) to recall, using the

SCENE RECALL buttons A to D on the front panel of the

SRP-X700P.

8 Information

Enter a comment for the setup file. You can enter up to 128 alphanumeric characters.

9 Power On Setting setup box

You can select the setup of the SRP-X700P at the time of power-on. Clicking the Power On Setting setup box displays the dropdown list. Select the desired setup.

• LAST MEMORY: The setup immediately before the previous power-off is set.

• DEFAULT: The default setup when shipped from the factory is set.

• SCENE No. 1: Scene No. 1 is recalled.

19

Section 2 User Control Panel

The User Control Panel software enables you to operate the SRP-X700P more simply from a personal computer that you may use for presentations and other purposes.

Note

Start up the User Control Panel after connecting the SRP-X700P to the personal computer.

To connect the SRP-X700P to the personal computer, use a USB cable (TYPE-B).

2

5

6

3

4

Names and Functions of Controls on Screen

AV CONTROL block

You can select an input machine connected to LINE 4 and operate the remote control of the selected machine.

1

2

1

5

2

3

6

1 MASTER index

Displays the indexes of the MASTER A and MASTER B that are set using the SRP-X700P Manager.

2 VOLUME button

Adjusts the MASTER volume level. Clicking the v or V button increases or decreases the MASTER volume level. (The volume knob of the SRP-X700P does not move.) This button is disabled during muting.

3 Fader position indicator (MASTER A and

MASTER B)

Indicates the VOLUME control position.

4 MUTING button

You can mute each MASTER channel. The VOLUME buttons lit in red are disabled during muting.

5 OVER GAIN indicator

The OVER GAIN indicator lights in red when the MASTER fader is increased exceeding the GAIN LIMIT set by the SRP-

X700P Manager. The sound volume does not increase even if the MASTER fader is increased exceeding the GAIN LIMIT value.

6

indicator

The –

∞ indicator lights in yellow if no sound is output during muting or when the INPUT fader is at the –

∞ level position.

SCENE RECALL Block

You can recall the scene that was memorized before using the SRP-

X700P Manager.

1 LINE4 input select button

This button corresponds to LINE4 input select buttons A to F of the SRP-X700P.

The button indicates an index that is set in the SRP-X700P by the SRP-X700P Manager.

The selected button lights in green.

2 REMOTE CONTROL button

You can remotely control the machine selected by the LINE4 input select button. If a machine that does not accept remote control signals is connected, remote control is disabled in the machine.

You can operate the functions PREV. (previous track), NEXT

(next track), STOP (stop), REW. (rewind), PLAY (playback),

F.F. (fast forward) and PAUSE (pause).

1 2

VOLUME control block

You can operate and mute the MASTER volume control of the

SRP-X700P from a remote location.

1 SCENE RECALL button

This button corresponds to the SCENE RECALL buttons A to

D on the front panel of the SRP-X700P. The selected SCENE button lights in green.

2 SCENE RECALL index

Displays the index set by the SRP-X700P Manager.

20

Troubleshooting

Before contacting a Sony Sales office or Dealer, check the following again. If the trouble persists, contact your local Sony Sales office or Dealer.

Symptom

Cannot operate the system from User

Control Panel.

Cannot operate the system using

SRP-X700P Manager.

Index is not displayed when using

User Control Panel.

Cannot operate FADER by remote control.

Cannot control the sound volume.

OVER GAIN indicator remains lit.

Cannot increase the sound volume more than a certain level.

No sound comes out.

PROTECTION indicator is lit.

Setup parameters change when power is turned off.

Cause/Remedy

• USB cable is not connected.

→ Check the connection of the USB cable.

• The dedicated USB driver software is not installed.

→ Install the dedicated USB driver software. (Refer to page 3.)

• Index is not set.

→ Set up the index using SRP-X700P Manager. (Refer to pages 7, 18, and 19.)

• FADER select is set to INACTIVE mode.

→ Set the FADER select to ACTIVE mode. (Refer to pages 9 and 13.)

• The SRP-X700P is not connected.

→ Check the connection of the SRP-X700P.

• There is an error in the GROUP FADER screen setup.

→ Check the GROUP FADER screen setup. (Refer to page 18.)

• Muting is on.

→ Cancel muting. (Refer to pages 8, 12, and 18.)

• FRONT PANEL LOCK button remains in the ON position.

→ Set the FRONT PANEL LOCK button to the OFF position. (Refer to page 6.)

• An attempt is made to increase the sound volume exceeding the OVER GAIN setup value.

→ Decrease the fader. (Refer to pages 9 and 13.)

→ Set up the GAIN LIMIT again. (Refer to pages 9 and 12.)

• FADER is set in the –

∞ position.

→ Increase the FADER. (Refer to pages 9 and 13.)

• Muting is on.

→ Cancel muting. (Refer to pages 8, 12, and 18.)

• Temperature of the heat sink inside the amplifier exceeds the specified value.

→ Turn off the main power and remove the cause of the temperature rise.

• Impedance of the speaker connected is too low.

→ Turn off the main power and connect the SRP-X700P to another speaker having the proper impedance.

• The speaker terminals are short-circuited.

→ Turn off the main power and remove the cause of the short-circuit.

• The “Power-On Setting” is set to DEFAULT or SCENE No. 1.

→ Set the “Power-On Setting” to LAST MEMORY. Alternatively, store the parameter in

SCENE No. 1 when the “Power-On Setting” is set to SCENE No. 1. (Refer to page 19.)

21

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project