FSP Brochure-Cover

P OWER

NEVER ENDS

STANDBY UPS

LINE INTERACTIVE UPS

ONLINE UPS

OFF-GRID INVERTER

ON-GRID INVERTER WITH ENERGY STORAGE

ACCESSORY

UPS SOLAR INVERTER

FSP Group is the leading switching power supplier in the world.

Since established in 1993, the company has drawn together its R&D expertise, sizeable production capacity and outstanding product quality to consistently excel in this competitive marketplace.

FSP Group produces large selections of products to serve its OEM / ODM customers in LCD TV, LED Lighting,

Medical, Industrial / Desktop computers and Servers. FSP Group has more than 28 branch offices worldwide,

4 manufacturing facilities and about 8,500 people throughout the world.

With its broad range of products, FSP Group is uniquely positioned for strong growth on several long term trends and environment protection including green power products, higher energy-efficient conversion products, and highly electrical safety and reliable products.

FSP Group’s global presence

in Taiwan, Brazil, China, Germany, Sweden, France, India, Japan, Korea, Russia,

Turkey, UK, USA also provide our OEM / ODM customers with integrated global logistic. This translates to

“Door-to-Door” service and faster time-to-market for product deliveries. Please check with your highly trained professional account manager on how to take advantage of our global logistic service for your business.

Our current focus

in FSP Group is to further enhance our green power products, expand market presence of FSP branded retail products, and extend our research and development effort on all our products. At FSP

Group, we are not only focusing on building a bigger company, also a better one.

Energetic Friendly Simple Reliable

P O W E R

NEVER ENDS

Applications:

TV HI-FI Game

Console

Computer

TECHNICAL SPECIFICATIONS

MODEL

CAPACITY

INPUT

Voltage

Voltage Range

Frequency Range

OUTPUT

AC Voltage Regulation(Batt. Mode)

Frequency Range(Batt. Mode)

Transfer Time

Waveform(Batt. Mode)

BATTERY

Battery Type

Numbers

Typical Recharge Time

INDICATORS

AC Mode

Battery Mode

Low Battery (Batt. Mode)

Fault

ALARM

Battery Mode

Low Battery (Batt. Mode)

Fault

PHYSICAL

Dimension, D x W x H(mm)

Net Weight (kgs)

ENVIRONMENT

Humidity

Operating Temperature

Product specifications are subject to change without further notice

Nano400

400 VA / 240 W

12V / 4.5 Ah

1

2.2

Nano Series

Standby UPS

Nano UPS provides comprehensive protection in a small and economic package, the compact size offer basic protection to against utility abnormal situations

- surges and spikes. FSP Nano will continue generating stable power to serve the connected equipments and able to shutdown PC safely when input power failure.

Embedded Microprocessor controller guarantees its reliability and suitable for home, small office, and power backup application.

GENERAL FEATURES

Compact size with stand and mounting flexibility

Excellent microprocessor controller guarantees high reliability

Auto restart while AC is recovering

Simulated sine wave output

Cold start function

Full protection: discharge, overcharge, short circuit, and thermal protection

3

Nano600

600 VA / 360 W

220/230/240 VAC

180-270 VAC

50 Hz or 60Hz (Auto sensing)

±10%

50 Hz or 60 Hz ± 1 Hz

2-6 ms

Simulated Sine Wave

12V / 7 Ah

1

8 Hours recover to 90% capacity

Green lighting

Green flashing every 10 seconds

Green flashing every second and red lighting

Red lighting

Sounding every 10 seconds

Sounding every second

Continuously sounding

228 (D) x 207 (W) x 82.5(H)

2.7

0-90 %

0- 40°C (non-condensing)

Nano800

800 VA / 480 W

12V / 9 Ah

3.1

1 www.fsp-ps.de

4

FP SERIES

Line Interactive UPS

400VA-2KVA

Applications:

Built-in AVR

Computer

Generator compatible

Game

Console

Simple Solution for Home and

Office Users

FP Series is a “Lite” UPS to protect your power issue on personal computers. It provides comprehensive protection in a small and economic package. Not only offering greater comprehensive power protection against surges and spikes, it also provides pure voltage with built-in AVR stabilizer. The UPS will continue providing clean and stable power to connected equipment while its embedded microprocessor controller guarantees high reliability, perfect for any home or small office application.

GENERAL FEATURES

Compact size

Excellent microprocessor control guarantees high reliability

Boost and buck AVR for voltage stabilization

Auto restart while AC is recovering

Simulated sine wave

Off-mode charging

Cold start function

Generator compatible(option)

FP Series

TECHNICAL SPECIFICATIONS

MODEL FP 400 FP 600 FP 800 FP 1000

1-phase in / 1-phase out

FP 1500 FP 2000

PHASE

CAPACITY

400 VA / 240 W 600 VA / 360 W 800 VA / 480 W 1000 VA / 600 W 1500 VA / 900 W 2000 VA / 1200 W

INPUT

Voltage

Voltage Range

Frequency Range

OUTPUT

Output Voltage

AC Voltage Regulation(Batt. Mode)

Frequency Range(Batt. Mode)

Transfer Time

Waveform(Batt. Mode)

BATTERY

Battery Type

Numbers

Typical Recharge Time

PROTECTION

Full Protection

INDICATORS

AC Mode

Battery Mode

Fault

12V / 4.5 Ah

1

ALARM

Battery Mode

Low Battery

Overload

Fault

PHYSICAL

Dimension, D x W x H(mm)

Net Weight (kgs)

3.55

ENVIRONMENT

Operation Humidity

Noise Level

Product specifications are subject to change without further notice

12V / 7 Ah

1

4 hours recover to 90% capacity

Green lighting

Green flashing

N/A

279 (D) x 101 (W) x 142 (H)

42

60/50 Hz (Auto sensing)

220/230/240 VAC

12V / 9 Ah

1

Less than 40 dBA @ 1 Meter

4-6 hours recover to 90% capacity

Overload, discharge, and overcharge protection

Sounding every 10 seconds

Sounding every second

Sounding every 0.5 second

4.9

220/230/240 VAC

162-290 VAC

±10%

50 Hz or 60 Hz ±1 Hz

Typical 2 -6 ms

Simulated Sine Wave

12V / 7 Ah

2

Continuously sounding

8.2

0-90% RH @ 0-40°C (non-condensing)

12V / 9 Ah

2

Green lighting

Yellow flashing

Red lighting

320 (D) x 130 (W) x 182 (H)

10.4

12V / 9 Ah

10.6

2

5

Backup time table for FP series

MODEL

Battery

FP 400

FP 600

FP 800

FP 1000

FP 1500

FP 2000

Type of Battery

12V 4.5Ah

12V 7.0Ah

12V 9.0Ah

12V 7.0Ah

12V 9.0Ah

12V 9.0Ah

NOTE : Data given are the average values, not the minimum values.

Total Q'ty

1

1

1

2

2

2

25% Load

15.0

19.0

20.0

18.0

18.0

15.0

Back Time (Min)

50% Load

8.0

6.0

3.0

5.0

6.5

3.73

75% Load

3.0

0.5

8.0

1.83

3.5

1.6

100% Load

0.67

0.08

0.08

0.46

1.33

0.6

www.fsp-ps.de

6

CP SERIES

Line Interactive UPS

750VA-2KVA

Applications:

POS Mini Servers

Computer

Built-in AVR

Pure Sine Wave UPS

With pure sine wave output waveform,

FSP CP 750/1K/1.5K/2K Series offers perfect power protection for sensitive equipment. It provides comprehensive LCD display for users to monitor the power and UPS status. CP implemented powerful protection and built-in automatic voltage regulator, it secures your data loss from power outage, surge, brownout and swell.

GENERAL FEATURES

Line interactive pure sine wave UPS

Digitalized PWM-based controller

Excellent microprocessor control guarantees high reliability

Boost and buck AVR for voltage stabilization

Optional USB and RJ45 protection

Perfect protection for mini servers, POS,& workstation

CP Series

TECHNICAL SPECIFICATIONS

MODEL CP 750 CP 1000 CP 1500

1-phase in / 1-phase out

CP 2000

PHASE

CAPACITY

INPUT

Voltage

Voltage Range

Frequency Range

OUTPUT

AC Voltage Regulation(Batt. Mode)

Frequency Range(Batt. Mode)

Transfer Time

Waveform(Batt. Mode)

BATTERY

Battery Type

Numbers

Typical Recharge Time

PROTECTION

Full Protection

INDICATORS

LCD Display

ALARM

Battery Mode

Low Battery

Battery Mode

Overload

Fault

PHYSICAL

Dimension, D x W x H(mm)

Net Weight (kgs)

ENVIRONMENT

Operation Humidity

Noise Level

60/50 Hz (Auto sensing)

12V / 7 Ah

2

220/230/240 VAC

162-290 VAC

6 hours recover to 90% capacity

AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Low Battery

MANAGEMENT

USB & RS-232 Port

Product specifications are subject to change without further notice

750 VA / 480 W

12V / 9 Ah

1

6.8

350 (D) x 146 (W) x 160 (H)

Less than 45dB

1000 VA / 700 W

9.0

±10%

1500 VA / 1050 W

50 Hz or 60 Hz ± 1 Hz

Typical 2-6 ms, 10ms max.

Pure SineWave

Overload, discharge, and overcharge protection

Sounding every 10 seconds

Sounding every second

Sounding every 0.5 seconds

Sounding every 2 second

Continuously sounding

12V / 9 Ah

2

0-90 % RH @ 0- 40°C (Non-condensing)

2000 VA / 1400 W

Less than 55dB

Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MAC

12V / 10 Ah

397 (D) x 146 (W) x 205 (H)

12.2

2

13.7

7

Backup time table for CP series

MODEL

CP 750

CP 1000

CP 1500

CP 2000

Type of Battery

12V 9.0Ah

12V 7.0Ah

12V 9.0Ah

12V 10Ah

NOTE : Data given are the average values, not the minimum values.

Battery

Total Q'ty

1

2

2

2

25% Load

18.0

28.0

18.0

16.0

Back Time (minutes)

50% Load

6.5

7.5

5.5

4.0

75% Load

2.5

4.3

3.0

2.17

100% Load

0.17

1.50

0.67

0.17

www.fsp-ps.de

8

EUFO SERIES

High-Level Line-Interactive UPS

1.1KVA-3KVA

Applications:

Work-Stations Rack server Network device

Multiple communication

Professional Line-Interactive UPS

Solutions

Eufo series rating is from 1.1kVA to 3.0kVA and implemented protect functions for power failure,surge overvoltage and brownout. Rack/Tower with easy-shift

LCD design is flexible for installation. moreover, this series built-in Efficiency corrective Optimizer(ECO) that the efficiency is up to 98% for more energy saving. The application is suitable for networking, telecom, server and mission-critical applications.

GENERAL FEATURES

Pure sine wave

Output power factor 0.9

Microprocessor control optimizes reliability

User-friendly and easy-shift LCD design

Rack/Tower 2 in 1 design

Built-in boost and buck AVR

Programmable power management outlets

ECO operation for energy saving

(Efficiency Corrective Optimizer)

Emergency power off function (EPO)

RJ45 Surge protector

Hot-swappable battery design

Built-in internal battery & extend battery function

Multiple communication available

Eufo Series

Microprocessor-based line interactive design

Eufo series UPS is designed with microprocessor controller for fast response to power disturbances.

Pure sine wave output

With pure sine wave output, Eufo series guarantees compatibility for all kinds of loads. It's perfect power protection for versatile applications such as networking, telecom and other mission-critical applications.

User-friendly and easy-shift LCD display

The front panel digital display can be easily shifted through LCD setting to suit the installation format, vertically stand or flat wall mount.

ECO operation for energy saving

(Efficiency Corrective Optimizer)

The ECO function allows cost-effective operation of

UPS Systems as high as 98%. In this operation mode, load is supplied by the mains. When battery is fully charged, the fan will stop running for energy saving.

In the event of a mains failure, the inverter takes over the load and provides supply continuity to the connected systems.

98%

ECO

Emergency Power Off Function (EPO)

This feature can secure the personnel and equipment in case of fires or other emergencies.

Hot-swappable battery design

This design ensures clean and uninterruptible power to protected equipment during battery replacement.

90°

Rack / Tower design

Eufo series is designed in true universal-mount case. It can be easily installed as floor-standing tower or in

19-inch rackmount bracket.

Extend battery capacity Function

Eufo series offer extend battery capacity function for long back up time purpose.

19" rack-mounting

Floor-standing Tower

Built-in boost and buck AVR

With built-in voltage regulator, the UPS will maintain regulated nominal output without using battery power during brownouts and overvoltages.

Output power factor 0.9

Eufo series is a high-density UPS with output power factor 0.9 to provide higher performance and efficiency to critical applications.

Programmable power management outlets

With programmable power management outlets, users can easily and independently control load segments.

During power failure, this feature enables users to extend battery time to missioncritical devices by shutting down the non-critical devices.

RJ-45 Surge protector

Eufo Series implements RJ-45 Surge Protection ports to prevent Ethernet network damage caused by lightning or ground surges.

Multiple communication

- USB port

- RS-232 port

- Intelligent slot for SNMP or Relay Card (option)

Also offer free monitoring software, ViewPower, downloaded from the internet. This advanced and networking software supports various operating systems and multiple languages.

SNMP Card AS400 Card

Programmable Outlets (P1)

- connect to non-critical devices www.fsp-ps.de

9

10

Eufo Series

TECHNICAL SPECIFICATIONS

MODEL

PHASE

EU-1101RS/TS EU-1102RS/TS

Single phase with ground

EU-1103RS/TS

CAPACITY 1100 VA / 990 W 2000 VA/ 1800 W 3000 VA/ 2700 W

INPUT

Voltage Range

Acceptable Voltage Range

Frequency Range

OUTPUT

Output Voltage

Voltage Regulation

Frequency Range(Batt. Mode)

Current Crest Ratio

Harmonic Distortion

Transfer Time

Waveform (Batt. Mode)

EFFICIENCY

ECO Mode

Boost/Buck Mode

Battery Mode

BATTERY

Standard

Model

Long-Run

Model

Battery Type & Numbers

Charging Current (max.)

Charging Voltage

Typical Recharge Time

Charging Current (max.)

Charging Voltage

ALARM

Battery Mode

Low Battery

Overload

Fault

AC INPUT & OUTPUT CONNECTORS

AC Input Connector

AC Output Connector

STANDARDS

Safety / EMC

PHYSICAL

Standard

Model

Long-Run

Model

Dimension,

Net Weight (kgs)

Dimension,

D x W x H(mm)

D x W x H(mm)

Net Weight (kgs)

ENVIRONMENT

Operation Humidity

Noise Level

MANAGEMENT

Smart RS-232 / USB

Optional SNMP

Product specifications are subject to change without further notice

89%

12 V/9 Ah x 2

27.4 VDC ± 1%

27.4 VDC ± 1%

1 x IEC 320 C14

8 x IEC 320 C13

410 (D) x 438 (W) x 88 (H)

13.4

410 (D) x 438 (W) x 88 (H)

9.0

208/220/230/240 VAC

162-290 VAC

50Hz/60Hz (Auto sensing)

208/220/230/240VAC

± 1.5% (Before battery Alarm)

50 Hz or 60 Hz ± 1 Hz

3:1 (max.)

2% max @ 100% linear Last ; 5% max @ 100% non linear load (Before low battery alarm)

2-6ms (typical), 10ms max.

Pure Sinewave

97%

95%

91%

12 V/9 Ah x 4

1.5 A

54.8 VDC ± 1%

4 hours recover to 90% capacity

1A/2A/4A/6A/8A

54.8 VDC ± 1%

Sounding every 10 seconds

SSounding twice every second

Sounding every second

Continuously sounding

1 x IEC 320 C14

8 x IEC 320 C13

IEC 62040-1 (safety) / IEC-62040-2 (EMC) / CE

510 (D) x 438 (W) x 88 (H)

21.5

410 (D) x 438 (W) x 88 (H)

10.8

0-90% RH @ 0-40°C (Non-condensing)

Less than 45 dBA @ 1 Meter

Supports Windows 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC

Power management from SNMP manager and web browser

92%

12 V/9 Ah x 6

82.1 VDC ± 1%

82.1 VDC ± 1%

1 x IEC 320 C20

6 x IEC 320 C13 / 1 x IEC C19

630 (D) x 438 (W) x 88 (H)

29.3

410 (D) x 438 (W) x 88 (H)

11.9

Backup Time Table for Eufo Series

EU-1101

EU-1102

EU-1103

Battery Bank

+ 1 BB-24/18RT ( 4 x 9Ah Batteries)

+ 2 BB-24/18RT ( 8 x 9Ah Batteries)

+ 3 BB-24/18RT (12 x 9Ah Batteries)

+ 4 BB-24/18RT (16 x 9Ah Batteries)

+ 1 BB-48/18RT ( 8 x 9Ah Batteries)

+ 2 BB-48/18RT (16 x 9Ah Batteries)

+ 3 BB-48/18RT (24 x 9Ah Batteries)

+ 4 BB-48/18RT (32 x 9Ah Batteries)

+ 1 BB-72/18RT (12 x 9Ah Batteries)

+ 2 BB-72/18RT (24 x 9Ah Batteries)

+ 3 BB-72/18RT (36 x 9Ah Batteries)

+ 4 BB-72/18RT (48 x 9Ah Batteries)

58

131

225

270

60

130

230

288

25%

Backup Time with Load (Min)

50% 75%

112

256

358

512

57

139

221

280

36

86

152

218

28

62

100

163

17

40

60

94

28

66

107

167

17

41

62

92

100 %

25

60

98

153

10

26

44

69

10

26

43

68 www.fsp-ps.de

KNIGHT SERIES

11

PF0.8 Online UPS

1KVA-10KVA

Applications:

Server POS ATM Computer

Reliable UPS Solution

Knight Series is specifically designed for operation in poor power areas. Built-in internal battery and extend battery connector in tower model, user can extend autonomy time via plug and play battery design. The

Reliable design is ideal for Banking, ATM, and other business critical application.

GENERAL FEATURES

True double-conversion

Microprocessor control optimizes reliability

Input power factor correction ≧ 0.99

Output power factor 0.8

Wide input voltage (110V–300V)

Converter mode available

ECO mode for energy saving

Generator compatible

SNMP Function operate with USB or RS-232 synchronizingly

Comprehensive LCD Display for access & setting

12

Knight Series

TECHNICAL SPECIFICATIONS

MODEL

PHASE

CAPACITY

KN-1101-TS KN-1102-TS

Single phase with ground

2000 VA / 1600W

KN-1103-TS

1000 VA / 800W 3000 VA / 2400 W

INPUT

Low Line Transfer

Voltage

Range

Low Line Comeback

High Line Transfer

High Line Comeback

Frequency Range

Power Factor

OUTPUT

Nominal Voltage

AC Voltage Regulation

Frequency Range(Synchronized Range)

Frequency Range(Batt. Mode)

Current Crest Ratio

Harmonic Distortion

Transfer

Time

AC mode to Battery mode

Inverter to Bypass

Waveform (Batt. Mode)

EFFICIENCY

Line Mode

Battery Mode

ECO Mode

BATTERY

Battery Type

Numbers

Typical Recharge Time

Charging Current (max.)

Charging Voltage

INDICATORS

LCD Display

88%

93%

87%

12V / 7 Ah

3

1.0 A

41.0 VDC ± 1%

160 VAC / 140 VAC / 120 VAC / 110 VAC ± 5 %

(Based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0)

168 VAC / 148 VAC / 128VAC / 118 VAC ± 5 %

(Based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0)

300 VAC ± 5 % or 150 VAC ± 5 %

290 VAC ± 5 % or 145 VAC ± 5 %

40Hz ~ 70 Hz

≧ 0.99 @ Nominal Voltage (100% Last)

200/208/220/230/240VAC

± 1%

47~ 53 Hz or 57 ~ 63 Hz

50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz

3:1

3 % THD (Linear Load), ≦ 6 % THD (Non-linear Load)

Zero

4 ms (Typical)

Pure Sinewave

90%

85%

88%

12V / 7 Ah

6

4 hours recover to 90% capacity

1.0 A

82.1 VDC ± 1%

91%

96%

89%

12 V / 9 AH

6

1.0 A

82.1 VDC ± 1%

Last level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators

ALARM

Battery Mode

Low Battery

Overload

Fault

AC INPUT & OUTPUT CONNECTORS

AC Input Connector

AC Output Connector

STANDARDS

Safety / EMC

PHYSICAL

1 x IEC 320 C14

4 x IEC 320 C13

Sounding every 4 seconds

Sounding every second

Sounding twice every second

Continously sounding

1 x IEC 320 C14

8 x IEC 320 C13

IEC 62040-1 (safety) / IEC-62040-2 (EMC) / CE

1 x IEC 320 C20

6 x IEC 320 C13 / 1 x IEC C19

Dimension, D x W x H(mm)

Net Weight (kgs)

UPS Unit: 397 (D) x 145 (W) x 220 (H)

Battery Pack:

397 (D) x 145 (W) x 220 (H)

UPS Unit: 13

Battery Pack: 18

UPS Unit: 419 (D) x 190 (W) x 318 (H)

Battery Pack:

535 (D) x 190 (W) x 318 (H)

UPS Unit:26

Battery Pack:49.4

ENVIRONMENT

Operation Humidity

Noise Level

MANAGEMENT

Smart RS-232 / USB

20-90% RH @ 0-40°C (non-condensing)

Less than 50 dBA @ 1 Meter

Supports Windows 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC

Optional SNMP

Power management from SNMP manager and web browser

*Derate to 80% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 100/200/208VAC

Product specifications are subject to change without further notice

UPS Unit: 419 (D) x 190 (W) x 318 (H)

Battery Pack:

535 (D) x 190 (W) x 318 (H)

UPS Unit:28

Battery Pack:67.5

Backup Time Table for Knight Series

Battery Bank

KN-1101TS

+ 1 BB-36/14T - 36V / 14 Ah

+ 2 BB-36/14T - 36V / 28 Ah

+ 3 BB-36/14T - 36V / 42 Ah

KN-1102TS

KN-1103TS

+ 1 BB-72/14T - 72V / 14 Ah

+ 2 BB-72/14T - 72V / 28 Ah

+ 3 BB-72/14T - 72V / 42 Ah

+ 1 BB-72/18T - 72V / 18 Ah

+ 2 BB-72/18T - 72V / 36 Ah

+ 3 BB-72/18T - 72V / 54 Ah

25%

29.41

97.66

155.41

249.08

Backup Time with Load (Min)

50%

15.55

49.80

78.56

125.16

75%

8.46

27.83

46.20

63.40

35.08

113.41

190.41

261.08

25.08

97.75

140.41

201.25

18.18

57.50

95.53

131.13

13.18

49.80

71.46

101.30

12.08

28.35

66.35

56.15

8.50

28.26

45.40

59.16

100 %

5.85

18.20

31.70

45.36

6.76

20.00

34.21

45.68

5.45

17.33

30.16

44.76

www.fsp-ps.de

Knight Series

TECHNICAL SPECIFICATIONS

MODEL

PHASE

KN-1101RL KN-1102RL KN-1103RL

Single phase with ground

KN-1106RL KN-1110RL

CAPACITY

INPUT

Nominal Voltage

1000 VA / 800W 2000 VA / 1600W 3000 VA / 2400 W

200/208/220/230/240VAC

6000 VA / 4800 W 10000 VA / 8000 W

Voltage Range

Frequency Range

Power Factor

OUTPUT

Nominal Voltage

AC Voltage Regulation

Frequency Range(Synchronized Range)

Frequency Range(Batt. Mode)

Overload

Current Crest Ratio

Harmonic Distortion

Transfer

Time

AC mode to Battery mode

Inverter to Bypass

Waveform (Batt. Mode)

EFFICIENCY

Line Mode

Battery Mode

ECO Mode

BATTERY

Battery Type

Numbers

Typical Recharge Time

Charging Current (max.)

Charging Voltage

INDICATORS

LCD Display

ALARM

Battery Mode

Low Battery

Overload

Fault

AC INPUT & OUTPUT CONNECTORS

AC Input Connector

AC Output Connector

STANDARDS

Safety / EMC

110-300 VAC ± 5% 110-300 VAC ± 5%

40Hz ~ 70 Hz

110-300 VAC ± 5%

≧ 0.99 @ Nominal Voltage (100% Last)

110-300 VAC @50% Load

176-300 VAC @100% Load

46Hz ~ 54 Hz or 56Hz ~ 64 Hz

200/208/220/230/240VAC

± 3%

47~ 53Hz or 57 ~ 63Hz

± 1%

46~ 54Hz or 56 ~ 64Hz

50Hz ± 0.25Hz or 60Hz ± 0. Hz

100%~110%:audible warning , 110%~130%: UPS shut down in 30 seconds at battery mode or transfer to bypass when the utility is normal >130%:UPS shuts down immediately at battery mode or transfer to bypass mode when the utility is normal 3:1 ( Max)

3:1 (Max)

3 % THD (Linear Load), ≦ 6 % THD (Non-linear Load)

4 ms (Typical)

Zero

50Hz ± 0.1Hz or 60Hz ± 0.1Hz

-

3% THD (Linear Load), ≦ 5% THD (Non-linear Load)

Zero

Pure Sinewave

88%

93%

87%

12V / 9 Ah

3

41 VDC ± 1%

90%

95%

88%

91%

96%

89%

Sounding every 4 seconds

Sounding every second

Sounding twice every second

Continuously sounding

90.3%

95.0%

88.0%

12V / 9 Ah

6

12V / 9 Ah

6

12 V / 9 AH 12 V / 9 AH

20 pcs (16-20 pcs adjustable)*

Depending on the capacity of external battery bank

1.0/2.0/4.0/6.0A ± 10%

82.1 VDC ± 1% 82.1 VDC ± 1%

Default:1.0 A ± 10%, Max.:2.0A ± 10%

273 VDC ± 1% (Based on 20 pcs batteries)

Last level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators

1 x IEC 320 C14

4 x IEC 320 C13

IEC 62040-1 (safety) / IEC-62040-2 (EMC) / CE

Terminal

Terminal

90.7%

96.0%

89.0%

PHYSICAL

Dimension,D x W x H(mm)

Net Weight (kgs)

Battery Pack:

410 (D) x 438 (W) x 88 (H)

UPS unit: 13

Battery Pack: 21.3

UPS Unit:

410 (D) x 438 (W) x 88 (H)

Battery Pack:

510 (D) x 438 (W) x 88 (H)

UPS unit: 8.3

Battery Pack: 28.7

Battery Pack:

630 (D) x 438 (W) x 88 (H)

UPS unit: 10

Battery Pack: 40.8

UPS Unit:

580 (D) x 438 (W) x 88 (H)

UPS Unit:

668 (D) x 438 (W) x 88 (H)

Battery Pack:

580 (D) x 438 (W) x 131 (H)

UPS unit: 15

Battery Pack: 48

UPS unit: 18

Battery Pack: 63

ENVIRONMENT

Operation Humidity

Noise Level

MANAGEMENT

Smart RS-232 / USB

Optional SNMP

20-90% RH @ 0-40°C (non-condensing)

Less than 50 dBA @ 1 Meter

Supports Windows 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC

Power management from SNMP manager and web browser

*Derate to 80% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 100/200/208VAC

Product specifications are subject to change without further notice

Less than [email protected] Meter Less than [email protected] Meter

13

Backup Time Table for Knight Series

KN-1101RL

KN-1102RL

KN-1103RL

KN - 1106RL

KN - 1110RL

Battery Bank

+1 BB-36/09RT

+1 BB-72/09RT

+2 BB-72/09RT

+1 BB-72/09RT

+2 BB-72/09RT

+1 BB-240/09RT

+2 BB-240/09RT

+1 BB-240/09RT

+2 BB-240/09RT

Backup Time with Load (Min)

25 % 50 % 75%

60 31.0

17.0

30.9

70.0

27.0

58.0

57

120

29.0

64.0

23.3

47.0

13.2

27.0

40.0

57.0

12.0

46.0

13.2

27.0

8.5

18.0

23.0

48.0

7.0

31.0

100%

12

8.5

18.0

5.3

11.0

9.0

40.0

4.0

17.0

www.fsp-ps.de

14

CHAMP SERIES

PF0.9 Online UPS

1KVA-3KVA

Applications:

Work-Stations

Network device

Generator compatible

Computer

Compact & Small-Scale Online

UPS Solutions

Champ Series is the high power density double-conversion online UPS with a output power factor 0.9. It’s designed in small cabinet with microprocessor controller.

Champ Series also have USB and RS-232 communication ports as standard, with a built-in intelligent slot for additional adapters, protocol converters and relate contact cards.

GENERAL FEATURES

True double-conversion

Microprocessor control optimizes reliability

Input power factor correction >=0.99

Output power factor 0.9

Wide input voltage (130V-280V)

Converter mode available

ECO mode for energy saving

Generator compatible

Smart SNMP works well with either USB or RS-232 together display allows easy monitoring and access of UPS status

Champ Series

TECHNICAL SPECIFICATIONS

MODEL

CH-1101-TS CH-1102-TS

Single phase with ground

CH-1103-TS

PHASE

CAPACITY 1000 VA / 900W 2000 VA / 1800W 3000 VA / 2700 W

INPUT

Low Line Transfer

Voltage

Range

Low Line Comeback

High Line Transfer

High Line Comeback

Frequency Range

Power Factor

OUTPUT

Nominal Voltage

AC Voltage Regulation

Frequency Range(Synchronized Range)

Frequency Range(Batt. Mode)

Current Crest Ratio

Harmonic Distortion

Transfer

Time

AC mode to Battery mode

Inverter to Bypass

Waveform (Batt. Mode)

EFFICIENCY

Line Mode

Battery Mode

ECO Mode

BATTERY

Battery Type

Numbers

Typical Recharge Time

Charging Current (max.)

Charging Voltage

INDICATORS

LCD Display

ALARM

Battery Mode

Low Battery

Overload

Fault

AC INPUT & OUTPUT CONNECTORS

AC Input Connector

AC Output Connector

STANDARDS

Safety / EMC

PHYSICAL

Dimension, D x W x H(mm)

Net Weight (kgs)

ENVIRONMENT

Operation Humidity

Noise Level

88%

83%

94%

12V / 9 Ah

2

1.0 A

27.4 VDC ± 1%

1 x IEC 320 C14

3 x CEE 7/4 (Schuko)

282 (D) x 145 (W) x 220 (H)

9.8

160 VAC / 140 VAC / 120 VAC / 110 VAC ± 5 %

(Based on Last percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0)

168 VAC / 148 VAC / 128VAC / 118 VAC ± 5 %

(Based on Last percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0)

300 VAC ± 5 % or 150 VAC ± 5 %

290 VAC ± 5 % or 145 VAC ± 5 %

40Hz ~ 70 Hz

≧ 0.99 @ Nominal Voltage (100% Last)

200/208/220/230/240VAC

± 1%

47~ 53 Hz or 57 ~ 63 Hz

50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz

3:1

2 % THD (Linear Load), ≦ 4 % THD (Non-linear Load)

Zero

4 ms (Typical)

Pure Sinewave

88%

87%

95%

12V / 9 Ah

4

4 hours recover to 90% capacity

1.0 A

54.7 VDC ± 1%

Last level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators

Sounding every 4 seconds

Sounding every second

Sounding twice every second

Continuously sounding

1 x IEC 320 C14

3 x CEE 7/4 (Schuko)

IEC 62040-1 (safety) / IEC-62040-2 (EMC) / CE

397 (D) x 145 (W) x 220 (H)

17.0

20-90% RH @ 0-40°C (non-condensing)

Less than 50 dBA @ 1 Meter

MANAGEMENT

Smart RS-232 / USB

Optional SNMP

Supports Windows 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC

Power management from SNMP manager and web browser

*Derate to 80% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 200/208VAC

Product specifications are subject to change without further notice

90%

88%

96%

12 V / 9 AH

6

1.0 A

82.1 VDC ± 1%

1 x IEC 320 C20

4 x CEE 7/4 (Schuko)

421 (D) x 190 (W) x 318 (H)

27.6

Backup Time Table for Champ Series

CH 1101TS

CH 1102TS

CH 1103TS

Battery Bank

Internal battery only (24V:12V-9Ah x 2)

Internal battery only (48V:12V-9Ah x 4)

Internal battery only (72V:12V-9Ah x 6)

25%

Backup Time with Load (Min)

50% 75%

24

26

31

11

12

13

6.0

6.5

7.0

100 %

4.0

4.0

4.5

15 www.fsp-ps.de

16

CUSTOS 9X+

SERIES

High-Level Online UPS

1KVA-10KVA

Applications:

Telecom

Networking

Computer

Data Center

Professional On-Line UPS Solutions

Ideal for medium-density power protection demand,

Power guardian, FSP Custos 9X+ series provides Rack/

Tower to fit diverse environment. Despite its compact footprint, Custos 9X+ incorporates internal battery packs which can be accessed via the front panel for maintenance checks and replacement without removing the UPS from its rack mounting. The LCD display panel can be easily shifted by pressing buttons to suit the installation format, vertical stand or horizontal rack mount. Besides, IT personnel can manage equipment well from learning Intuitive information via LCD display.

GENERAL FEATURES

True double-conversion online UPS

Output power factor 0.9

User-friendly and easy-shift LCD display

Rack/Tower design

Programmable power management outlets

50/60 Hz frequency converter mode

ECO and advanced ECO mode for energy saving

Emergency Power Off Function (EPO)

Hot-swappable battery design

Parallel option for 6K-10K models

True double-conversion online UPS

A true double conversion UPS will rectify input power to offer clean,pure, high level quality power with ± 1% voltage output regulation to fully protect mission-critical devices such as sensitive networks, small computer centers servers, telecom applications, as well as for industrial applications.

Output power factor 0.9

Custos 9X+ series is a high-density UPS with output power factor 0.9 to provide higher performance and efficiency to critical applications.

User-friendly and easy-shift LCD display

The front panel digital display can be easily shifted through LCD setting to suit the installation format, vertically stand or flat wall mount.

90°

50/60 Hz frequency converter mode

Lock output frequency at 50Hz or 60Hz to suit power sensitive equipments.

ECO and advanced ECO mode for energy saving

Thanks FSP Custos9X+ smart design, operation efficiency up to 97% ECO mode implemented.

Furthermore, Custos 9X+ 1-3K even offers advanced

ECO mode to allow UPS to operate at higher efficiency up to 98% for more energy saving.

In these operation modes, load is supplied by the utility. When utility failure, UPS inverter will assume control the load and provide clean power continuity to the connected devices.

98%

Emergency Power Off function (EPO)

The safety function can guarantee & secure the emergency responders, fire fighters not exposed to dangerous voltage, electrical hazard from the device.

This is important if equipment is emitting smoke, fire, or flood, or if person is being electrocuted.

Hot-swappable battery design

This design ensures clean and uninterruptible power to protected equipment during battery replacement.

Rack / Tower design

Custos 9X+ series is designed in true universal-mount case. It can be easily installed as floor-standing tower or in 19-inch rackmount bracket.

19" rack-mounting

Floor-standing Tower

Programmable power management

With programmable power management outlets, users can easily and independently control load segments.

During power failure, this feature will extend battery time to mission critical devices by shutting down the non-critical devices.

RJ-45 Surge protector

Custos 1-3kVA implements RJ-45 Surge Protection ports to prevent Ethernet network damage caused by lightning or ground surges.

Intelligent slot for SNMP or Relay Card

SNMP Card AS400 Card

Parallel Option N+X for 6K-10K models

Custos 9X+ 6K/10K can be parallel operated with up to 3 units to accommodate increses in power demand as well as to attain power redundancy with high system integrity.

17

Programmable Outlets (P1)

- connect to non-critical devices www.fsp-ps.de

18

Custos 9X+ Series

TECHNICAL SPECIFICATIONS

MODEL CU-1101

PHASE

CAPACITY

1000 VA / 900 W

INPUT

Low Line Transfer

Voltage Range

Low Line Comeback

Frequency Range

Power Factor

High Line Transfer

High Line Comeback

OUTPUT

Output Voltage

Frequency Range (Synchronized Range)

Transfer Time

Line mode to Battery mode

Inverter to Bypass

CU-1102

Single phase with ground

2000 VA / 1800 W

110/115/120/127 VAC or 208/220/230/240 VAC

± 1%

47 ~ 53 Hz or 57 ~ 63 Hz

50 Hz ± 0.2 Hz or 60Hz ± 0.2 Hz

5:1 (max.)

2 % THD (Linear Load) ;

4 % THD (Non-linear Load)

Zero

4 ms (Typical)

Pure Sinewave

CU-1103

3000 VA / 2700 W

80 VAC / 70 VAC / 60 VAC / 55 VAC ± 5 % or 160 VAC / 140 VAC / 120 VAC / 110 VAC ± 5 %

(Based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0)

85 VAC / 75 VAC / 65 VAC / 60 VAC ± 5 % or 170 VAC / 150 VAC / 130 VAC / 120 VAC ± 5 %

(Based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0)

150 VAC ± 5 % or 300 VAC ± 5 %

140 VAC ± 5 % or 290 VAC ± 5 %

40Hz ~ 70Hz

0.99 @ Nominal Voltage (100% load)

EFFICIENCY

AC Mode

Battery Mode

ECO Mode

BATTERY

87%

94%

85%

88%

95%

86%

89%

97%

87%

Numbers

Typical Recharge Time

Charging Current (max.)

Charging Voltage

INDICATORS

LCD Display

ALARM

12 V / 9 AH

2

4 hours recover to 90% capacity

1.0 A

27.4 VDC ± 1%

12 V / 9 AH

4

12 V / 9 AH

6

STD 4hr recover to 90% cap/ LongRun Model depend on external battery capacity

Standard:1.0A / LongRun Model: 1A/2A/4A/8A

54.8 VDC ±1% 82.1 VDC ±1%

Sounding every 4 seconds

Sounding every second

Sounding twice every second

Continuously sounding

Overload

Fault

AC INPUT & OUTPUT CONNECTORS

AC Input Connector

AC Output Connector

PHYSICAL

Dimension, D x W x H (mm)

Net Weight (kgs)

ENVIRONMENT

Humidity

Noise Level

MANAGEMENT

Smart RS-232 / USB

Optional SNMP

*LongRun Model without internal battery.

1 x IEC 320 C20

8 x IEC 320 C13

410 x 438 x 88 [2U]

12.9

1 x IEC 320 C20

8 x IEC 320 C13

Standard:630 x 438 x 88 [2U] /

LongRun Model: 410 x 438 x 88 [2U]

Standard:20.6/ LongRun Model: 11.3

0-95 % RH @ 0- 40°C (non-condensing)

Less than 50dBA @ 1 Meter

1 x IEC 320 C20

1 x IEC 320 C19 / 6 x IEC 320 C13

Standard:630 x 438 x 88 [2U] /

LongRun Model: 510 x 438 x 88 [2U]

Standard:27.4 / LongRun Model: 13.8

Supports Windows 2000/2003/XP/Vista/2008, Windows7/8/10, Linux and MAC

Power management from SNMP manager and web browser

Backup Time Table for Custos Series

CU-1101

CU-1102

CU-1103

Battery Bank

internal battery (2 x 9Ah Batteries)

+1 BB-24/18RT (6 x 9AH Batteries)

+2 BB-24/18RT (10 x 9AH Batteries)

+1 BB-48/9RT ( 4 x 9AH Batteries)

+1 BB-48/18RT ( 8 x 9AH Batteries)

+2 BB-48/18RT (16 x 9AH Batteries)

+3 BB-48/18RT (24 x 9AH Batteries)

+1 BB-72/9RT (6 x 9AH Batteries)

+1 BB-72/18RT (12 x 9AH Batteries)

+2 BB-72/18RT (24 x 9AH Batteries)

+3 BB-72/18RT (36 x 9AH Batteries)

25%

Backup Time with Load (Min)

50% 75%

27.0

87.3

156.0

11.0

37.7

70.4

6.0

22.6

43.0

21.0

52.1

117.5

184.0

8.9

22.0

52.0

84.0

4.8

13.1

31.6

52.0

21.9

52.1

117.6

184.0

8.9

21.9

52.0

84.5

4.9

13.1

31.6

52.2

100 %

3.5

16.0

33.2

4.2

8.9

22.0

36.0

4.0

8.9

21.9

36.6

www.fsp-ps.de

Custos 9X+ Series

TECHNICAL SPECIFICATIONS

MODEL CU-1106 CU-1110

PHASE

CAPACITY

Single phase with ground

6000 VA / 5400 W 10000 VA / 9000 W

INPUT

Low Line Transfer

Voltage

Range

Low Line Comeback

High Line Transfer

High Line Comeback

Frequency Range

Power Factor

OUTPUT

Nominal Voltage

AC Voltage Regulation

Frequency Range(Synchronized Range)

Frequency Range(Batt. Mode)

Current Crest Ratio

Harmonic Distortion

Transfer

Time

AC mode to Battery mode

Battery mode to AC mode

Inverter to Bypass

Bypass to Inverter

Waveform (Batt. Mode)

EFFICIENCY

Line Mode

Battery Mode

ECO Mode

176 VAC @ 100% load

110VAC @ 50% load

186 VAC @ 100% load

120VAC @ 50% load

300 VAC

290 VAC

46~54 Hz or 56~64 Hz

0.99 @ 100% Load

200/208/220/230/240 VAC

± 1%

46~54 Hz or 56~64 Hz

50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz

3:1 (max.)

2 % THD (Linear Load), ≦ 4 % THD (Non-linear Load)

Zero

Zero

Zero

Zero

Pure Sinewave

91%

96%

88%

BATTERY

Nominal Voltage

Battery Type

Numbers

Charging Current (max.)

Float Charging Voltage

240 VDC

12 V / 7 AH

20 (18-20 pcs adjustable)*

1.0 A

273 VDC (based on battery numbers at 20 pcs)

12 V / 9 AH

20 (18-20 pcs adjustable)*

1.0 A

INDICATORS

LCD Display

ALARM

Battery Mode

Low Battery

Overload

Fault

AC INPUT & OUTPUT CONNECTORS

AC Input Connector

AC Output Connector

PHYSICAL

UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions

Sounding every 4 seconds

Sounding every second

Sounding twice every second

Continuously sounding

Terminal

Terminal

Dimension, D x W x H(mm)

Net Weight (kgs)

UPS unit: 606 x 438 x 133 [3U]

Battery pack:

606 x 438 x133 [3U]

UPS unit: 20

Battery pack: 58

UPS unit: 668 x 438 x 133 [3U]

Battery pack:

606 x 438 x133 [3U]

UPS unit: 23.5

Battery pack: 65

ENVIRONMENT

Operation Humidity

Noise Level

MANAGEMENT

Smart RS-232 / USB

Optional SNMP

0-95 % RH @ 0- 40°C (non-condensing)

Less than 58 dBA @ 1 Meter

Supports Windows 2000/2003/XP/Vista/2008, Windows7/8/10, Linux and MAC

Power management from SNMP manager and web browser

*When using internal batteries from 18-19, the unit will de-rate according to below formula: P=PRating x N/20

** If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated one percent per 100m.

* L means long-run model

Product specifications are subject to change without further notice

Less than 60 dBA @ 1 Meter

Backup Time Table for Custos Series

CU-1106

CU-1110

Battery Bank

+1 BB-240/9RT (20 x 9AH Batteries)

+2 BB-240/9RT (40 x 9AH Batteries)

+3 BB-240/9RT (60 x 9AH Batteries)

+1 BB-240/9RT (20 x 9AH Batteries)

+2 BB-240/9RT (40 x 9AH Batteries)

+3 BB-240/9RT (60 x 9AH Batteries)

25%

Backup Time with Load (Min)

50% 75%

43.0

99.0

150.0

20.0

46.0

71.0

12.9

31.7

43.5

22.0

54.0

88.0

9.0

23.0

38.0

6.0

16.9

23.0

100 %

8.0

22.7

30.4

3.0

12.0

16.0

www.fsp-ps.de

19

20

PROLINE SERIES

3Phase in -3/Single Phase Out

Online UPS

10KVA-40KVA

Applications:

Data Center Networking

Computer Banking

Generator compatible

On-Line UPS Solutions

3 Phase Tower UPS Solutions FSP Proline 3P/3P, 3P/1P

Online UPS series integrates true double conversion design, DSP technology, and active input power factor correction design to ensure output power quality and performance at all times. N+X redundancy function available reduce power failure or lost rick. Besides, easy-configurable program via LCD panel enhances the flexibility to meet ever-increasing power demand of IT and networked environment.

GENERAL FEATURES

True double-conversion

DSP technology guarantees high performance

Output power factor 0.8

Wide input voltage range (110-300 VAC)

Active power factor correction in all phases

50Hz/60Hz frequency converter mode

ECO mode operation for energy saving

Emergency power off function (EPO)

SNMP+USB+RS-232 multiple communications

3-stage extendable charging design for optimized battery performance

Accepts dual-mains inputs

Generator compatible

Battery number adjustable

Maintenance bypass available

Optional N+X parallel redundancy

Optional isolation transformer offers full isolation and complete common mode noise rejection

Proline Series

TECHNICAL SPECIFICATIONS

MODEL

PHASE

PR-3110TL

PR-3120TL

3-phase in / 1-phase out

PR-3130TL

CAPACITY

10.0 kVA / 8kW 20.0 kVA / 16kW 30.0 kVA / 24kW

INPUT

Voltage Range

Frequency Range

Power Factor

OUTPUT

Output Voltage

Voltage Regulation

Frequency Range ( Synchronized Range)

Frequency Range (Batt. Mode)

Current Crest Ratio

Harmonic Distortion

Transfer Time

Bypass to Inverter

Inverter to Bypass

Waveform (Batt. Mode)

305-478 VAC (3-phase) @ 100% Last

190-520 VAC (3-phase) @ 50% Last

46Hz ~ 54Hz or 56Hz ~ 64Hz

≧ 0.99 @ 100% Last

208/220/230/240 VAC (3Ph + N)

± 1%

46Hz ~ 54Hz or 56Hz ~ 64Hz

50Hz ± 0.1Hz or 60Hz ± 0.1Hz

3:1 (max.)

≦ 2% THD (Linear Last) ; ≦ 5% THD (Non-linear Last)

Zero

Zero

Pure Sinewave

EFFICIENCY

AC Line Mode

Battery Mode

BATTERY

Battery Type

Numbers

Charging Current (max.)

Charging Voltage

ALARM

Battery Mode

Low Battery

Overload

Fault

AC INPUT & OUTPUT CONNECTORS

AC Input Connector

AC Output Connector

STANDARDS

Safety / EMC

PHYSICAL

Dimension,

D x W x H(mm)

Net Weight (kgs)

ENVIRONMENT

Operation Humidity

Noise Level

89%

86%

4.0 A

592 (D) x 250 (W) x 826 (H)

38

89%

88%

Depending on the capacity of external batteries

4.0 A

273 VDC ± 1% (based on 20 pcs batteries)

Sounding every 4 seconds

Sounding every second

Sounding twice every second

Continuously sounding

Terminal

Terminal

IEC 62040-1 (safety) / IEC-62040-2 (EMC) / CE

592 (D) x 250 (W) x 826 (H)

40

91.3%

88%

4.0 A

815 (D) x 250 (W) x 826 (H)

64

Less than 58dBa @ 1 Meter

0-90% RH @ 0-40°C (non-condensing)

Less than 60dBa @ 1 Meter Less than 65dBa @ 1 Meter

MANAGEMENT

Smart RS-232 / USB

Optional SNMP

Windows® 2000/2003/XP/Vista/2008 and Windows® 7/8 /Windows SBS 2011 and Windows server 2012

Power management from SNMP manager and web browser

*When using internal batteries from 18-19, the unit will de-rate according to the below formula: P = PRating x N/20.

Product specifications are subject to change without further notice

21

Rackmount/Rack Tower Battery Pack

Form Factor

Model Name

Battery Type

Battery Number

Dimension (DxWxH) mm

Net Weight (kgs)

Tower Battery Pack

Form Factor

Model Name

Battery Type

Battery Number

Charger

Dimension (DxWxH) mm

Net Weight (kgs)

3U

BB-240/RT

12 V / 9 Ah

20 pcs

580 x 438 x 131 [3U]

65

BB-240/18T

12 V / 9 Ah

40 pcs x

592 x 250 x 576

125

Tower

BB-240/27T

12 V / 9 Ah

60 pcs

4A

830 x 250 x 576

190 www.fsp-ps.de

22

Proline Series

TECHNICAL SPECIFICATIONS

MODEL

PHASE

CAPACITY

PR-3310TL

10.0 kVA / 8kW

PR-3320TL PR-3330TL

3 phase in / 3 phase out

20.0 kVA / 16kW 30.0 kVA / 24kW

PR-3340TL

40.0 kVA / 36kW

INPUT

Voltage Range

Frequency Range

Power Factor

OUTPUT

Output Voltage

Voltage Regulation

Frequency Range ( Synchronized Range)

Frequency Range (Batt. Mode)

Current Crest Ratio

Harmonic Distortion

Transfer Time

Bypass to Inverter

Inverter to Bypass

Waveform (Batt. Mode)

EFFICIENCY

AC Line Mode

Battery Mode

305-478 VAC (3-phase) @ 100% Load

190-520 VAC (3-phase) @ 50% Load

46Hz ~ 54Hz or 56Hz ~ 64Hz

≧ 0.99 @ 100% Load

3x400 VAC (3Ph + N)

± 1%

46Hz ~ 54Hz or 56Hz ~ 64Hz

50Hz ± 0.1Hz or 60Hz ± 0.1Hz

3:1 (Max.)

≦ 2% THD (Linear Load) ; ≦ 5% THD (Non-linear Load)

Zero

Zero

Pure Sinewave

89%

86%

89%

88%

89%

87%

95%

92%

BATTERY

Battery Type

Numbers

Charging Current (max.)

Charging Voltage

ALARM

Battery Mode

Low Battery

Overload

Fault

AC INPUT & OUTPUT CONNECTORS

AC Input Connector

AC Output Connector

STANDARDS

Safety / EMC

PHYSICAL

Dimension, D x W x H(mm)

Net Weight (kgs)

ENVIRONMENT

Operation Humidity

Noise Level

4.0 A 4.0 A

273 VDC ± 1% (based on 20 pcs batteries)

592 (D) x 250 (W) x 826 (H)

38

Depending on the capacity of external batteries

Sounding every 4 seconds

Sounding every second

Sounding twice every second

Continuously sounding

592 (D) x 250 (W) x 826 (H)

40

Terminal

Terminal

4.0 A

IEC 62040-1 (safety) / IEC-62040-2 (EMC) / CE

815 (D) x 250 (W) x 826 (H)

62

16 ~20 pcs (Adjustable)

4.0 A

+/- 13.65V x N (N=16~20)

592 (D) x 250 (W) x 576 (H)

45

Less than 58dBa @ 1 Meter

0-90% RH @ 0-40°C (non-condensing)

Less than 60dBa @ 1 Meter

< 95% RH @ 0-40°C (non-condensing)

Less than 75dBa @ 1 Meter

MANAGEMENT

Smart RS-232 / USB

Optional SNMP

Windows® 2000/2003/XP/Vista/2008 and Windows® 7/8 /Windows SBS 2011 and Windows server 2012

Power management from SNMP manager and web browser

*When using internal batteries from 18-19, the unit will de-rate according to the below formula: P = PRating x N/20.

Product specifications are subject to change without further notice

Backup Time Table for Proline Series

PR-3310TL

PR-3110TL

PR-3320TL

PR-3120TL

PR-3330TL

PR-3130TL

Battery Bank

+ 1 BB-240/9RT - 240V / 9 Ah

+ 1 BB-240/18T - 240V / 18 Ah

+ 2 BB-240/18T - 240V / 36 Ah

+ 1 BB-240/27T - 240V / 27 Ah

+ 2 BB-240/27T - 240V / 54 Ah

+ 1 BB-240/18T- 240V / 18 Ah

+ 2 BB-240/18T - 240V / 36 Ah

+ 1 BB-240/27T - 240V / 27 Ah

+ 2 BB-240/27T - 240V / 54 Ah

+ 1 BB-240/27T - 240V / 27 Ah

+ 2 BB-240/27T - 240V / 54 Ah

+ 3 BB-240/27T - 240V / 81 Ah

25 %

25

61

136

98

200

Backup Time with Load (Min)

50 % 75%

12.5

26

61

43

98.2

5.5

15.5

37

26

61

25.9

61

43

98

10.6

26

18

43

6.0

15.5

10.6

26

26

61

98.2

11

26

43

6.0

16

26

100 %

2.5

12.5

51

18

43

7.1

12.7

7.1

18

4

10.6

18.0

www.fsp-ps.de

AGIES SERIES

23

3 Phase High Efficiency UPS

10-120kVA

Telecom Networking Medical Industrial

machinery

3-Level Design UPS

Agies is applied to the high technology to reach high efficiency with output power factor 0.9. It can easily adapt to all kinds of diverse and complicated loads, such as the non-linear systems (IT systems), strongly inductive or capacitive loads, discharge lamps, and induction motors. To meet diverse applications, it is allowed to have alternative battery configuration based on different backup time requirement. To facilitate expansion easily, this unit can be set up in parallel-redundant systems with up to 4 units.

GENERAL FEATURES

Online double conversion technology with DSP control

Advanced control with Adaptive Feed Forward

Cancellation (AFC) technology for

Low harmonic distortion

Input current distortion THDi < 1%

Input power factor 0.99 at 10% load

Output efficiency up to 95%

Space-saving compact design

Front access makes maintenance and replacement easily

Control designed to withstand all kinds of loads

Parallel redundant operation with up to 4 units

Variety of communication options available

Remaining backup time calculation

5.7" Graphic LCD panel design with multiple languages for easy-configuration

24

Agies Series

The Most Versatile Solution for Power Protection

Agies, applied with state-of-the-art PWM-transformerless technology, can easily adapt to all kinds of diverse and complicated loads, such as the non-linear systems (IT systems), strongly inductive or capacitive loads, discharge lamps, and induction motors. Ranging from 10K-120KVA, Agies is designed in terms of criteria of maximum efficiency and energy savings with highly compact format. It makes installation and operation easily and eco-environmentally.

Each unit also has a wide range of communication possibilities and a large variety of options to fill out customers’ diverse inquiries. To facilitate expansion easily, this unit can be set up in parallel-redundant systems without any need for additional hardware in the near future

Online double conversion technology with

DSP control

Agies is applied online double conversion technology to effectively insulate against network disturbances and enable higher load uptime. A

Digital Signal Processor (DSP) control provides an improved solution with high performance.

Advanced control with Adaptive Feed

Forward Cancellation (AFC) technology for very low harmonic distortion

By cancelling input current and output voltage harmonics, the harmful effects of harmonic injection into the power network is eliminated and it will enhance load integrity.

Very low input current distortion (THDi < 1%)

AFC cells are used to achieve extremely low distortion values. Low input current distortion rat

THDi < 1% at full load and also THDi < 5% with very small load (10% of load). This will avoid the distortion of the electrical network upstream of the UPS, resulting in savings from the optimal use of the cables and protection devices in the electrical network.

Output efficiency up to 95%

Applied with DSP controller and the forth generation

IGBT transistors, the UPS can achieve high efficiency of up to 95%. It will save consumed energy due to lower heat losses and make a longer lifespan for the critical components of the unit.

20K EFF ICIENCY

EFFICIENCY

100%

80%

60%

40%

20%

0%

20% 40%

LOAD

60% 80% 100%

Space-saving compact design

The use of transformerless technology allows a considerable reduction of the weight and volume of the units.

Input power factor 0.99 at 10% load

Lower power losses would result in reduced consumption, lower operation and maintenance costs.

INPUT POWER FACTOR

1,20

1,00

0,80

0,60

0,40

0,20

0,00

0% 25% 50%

LOAD

75% 100%

Front access makes maintenance and replacement easily

An important consideration has been given to allow generous access to the unit’s electronic cards and power components. All the boards are accessible by front panel for easily maintenance and replacement.

www.fsp-ps.de

Agies Series

Control designed to withstand all kinds of loads

In Agies series, the control is designed to be able to withstand all kinds of loads: resistive, capacitive, non-linear, discharge lamps, induction motors, speed drivers, etc. It makes the UPS tremendously versatile and flexible in supplying power to different types of electronics. To make it simple to adapt the

UPS for different environment, there are a large number of parameters that can be programmed locally or remotely.

Parallel redundant operation with up to 4 units

Up to 4 units in parallel can be operated without additional hardware, to accommodate increases in power demand as well as to attain power redundancy with high system integrity.

Variety of communications and options available

The UPS has provided the following standard communication selections:

Relay interface

RS-232/485 port

1 x SNMP slot

Modbus RTU / SEC protocol

2 x connectors for parallel connection

Over 60% materials recyclable

The UPS uses more than 60% recyclable materials for being more respectful of the environment.

Remaining backup time calculation

By using powerful algorithms, an estimated remaining backup time can be calculated and help users for further arrangement in the event of a prolonged power outage.

Optional fast-access touch screen for 5.7" LCD panel

We also offer touch panel for 5.7" LCD panel. Touch screen provides higher operability on configuration and information display.

5.7" graphic LCD panel design with multiple languages for easy-configuration

With graphic design, it becomes more intuitive to configure programs. Besides, we also offer multiple languages for 5.7" LCD version. Users can easily configure programs and read displayed messages.

EN FR ES DE CN

Applications:

Agies vides great flexibility and adaptability to suit versatile applications.

Data centers (computing centers, centralized sales/distribution systems, hosting, housing, ...)

IT-networks (server farms, local computer networks, network switches and hubs,...)

Financial services (bank offices, automatic cash dispensers, card payment authorisation systems,...)

Industrial processes (productive and control systems, industrial machinery, emergency and lighting systems,...)

Telecommunications

Infrastructures (hospitals, airports, tunnels,...)

25 www.fsp-ps.de

26

Agies Series

TECHNICAL SPECIFICATIONS

MODEL

PHASE

CAPACITY

INPUT

Nominal Voltage

Acceptable Voltage Range

Frequency

Agies 10K Agies 15K Agies 20K Agies 30K Agies 40K Agies 60K Agies 80K Agies 100K Agies 120K

3-phase in / 3-phase out

10KVA/9KW 15KVA/13.5KW 20KVA/18KW 30KVA/27KW 40KVA/36KW 60KVA/54KW 80KVA/72KW 100KVA/90KW 120KVA/108KW

< 1.5% @ 100% load

< 6.0% @ 10% Load

3 x 400V (3Ph + N)

+15% or –20%

50 / 60 Hz ±5 %

< 1.0% @ 100% load

< 5.0% @ 10% Load

< 1.5% @ 100% Load

< 6.0% @ 10% Load

Power Factor

INVERTER

Nominal Voltage

Precision

Frequency

M

Waveform

1.0

3 x 400V (3Ph + N)

50/60 Hz synchronised ±4 % With mains absent ±0.05%

10 Hz/s

Pure Sinewave

< 0.5% (Linear Load) ; < 1.5% (Non-linear Load)

120º ±1% (Balanced load) ; 120º ±2% (imbalances 50% of the load) Phase Displacement

Dynamic Recovery Time

Admissible Overload

Admissible Crest Factor

Admissible Power Factor

Imbalance Output [email protected] 100%

Unbalanced Load

Current Limit

STATIC BYPASS

Type

Voltage

Frequency

Phase Overload: 125% for 10 min., 150% for 60s ; Total Overload: 112.5% for 10 min., 135% for 60s

3.4 : 1 3.2 :1

<1%

2.8 : 1

High overload, short-circuit: RMS Voltage Limit ; High Crest-Factor current: Peak Voltage Limit

3.2 :1

Transfer Time

Admissible Overload

Transfer to Bypass

Retransfer

MAINTENANCE BYPASS

Type

Voltage

Frequency

90.0% 90.5% 91.0%

Solid state

3x400V (3Ph + N)

50/60 Hz

Microprocessor control

Zero

400% for 10 sec.

Immediate, for overloads above 150%

Automatic after alarm clear

92.0%

Without interruption

3 x 400V (3Ph + N)

50/60 Hz

92.5% 93.0% 94.0% 93.0%

BATTERY

Back-up Time (minutes)

Max. Charging Current

12V 4.5Ah

5

12V 4.5Ah

3

23.5 A

12V 7Ah

5

12V 9Ah

3

12V 12Ah

3

47 A

-

-

70.5 A

PHYSICAL

Dimension, D x W x H(mm)

Ne 78

178

86

186

770 x 450 x 1100

94

249

110

290

122

357

162 231

805 x 590 x 1320

-

*NOTE: When temperature is above 30°C, the output power will be derated. The output power is derated to 90% at 31°C -35°C and 80% at 36°C -40°C.

255

93.3%

188 A

External Battery Cabinet for HV

Dimensions, D x W x H (mm)

Built-in Battery Type

Battery Numbers

Net Weight (Kg)

700 x 450 x 1100

12V 12Ah

Dimensions, D x W x H (mm)

Built-in Battery Type

Battery Numbers

Net Weight (Kg)

250

Type 2

805 x 590 x 1320

12V 26Ah

710

*Product specifications are subject to change without further notice.

Type 1

62 pcs (2 x 31)

62 pcs (2 x 31)

700 x 450 x 1100

12V 18Ah

410

Type 3

980 x 650 x 1320

12V 40Ah

1020 www.fsp-ps.de

MPLUS SERIES

27

Hot Swappable Modular UPS

30-210kVA / 20-200kVA

Data Center Networking Industrial Banking

PowerFactor 1 Modular UPS

Mplus series is a truly double converion online modular UPS with high scales from 20kW/30kW to

200kW/210kW. Modular design implemented in STS,

Power module, and battery, it achieves low MTTR, technican will streamline and simplify their maintenance and replacement, furthermore end customer will be more flexable, more convenient to escalate their power demand in the future.

GENERAL FEATURES

Power Factor 1.0** (kVA = kW)

Efficiency up to 94.5%

20/30 kVA per module

Adjustable charging current

Adjustable Battery Voltage

Dual input function

Power modules are hot swappable

Redundancy ready

Easy maintenance in service

Emergency power off function (EPO)

Maintenance Bypass included

5,7" LCD Panel

28

Mplus Series

High efficiency online double conversion technology

Mplus is applied online double conversion technology with high performance over 94.5% at 50% load. It significantly reduces overall Total Cost of Ownership

(TCO).

High scalability

DSP control provides an improved solution with high performance. Integrated with modular design and parallel technology, Mplus simplifies future power expansion.

Unity output power factor

Mplus delivers unity output power (kVA=kW) providing the maximum power capacity to mission critical loads. It satisfies the requirements of the latest servers and optimizes IT investment with every penny.

Modular design lowers MTTR

Modular design is applied in power module, STS module and battery module. It will simplify maintenance and replacement with low MTTR (Mean Time To Repair).

N+1 or N+X parallel redundancy for power guarantee

Scalable architecture allows you to optimize cost expense to meet power demands by vertically expanding in a single rack enclosure from 30KVA to

210KVA and achieve N+1 or N+X redundancy in the same rack.

Optional 10" touch LCD panel

Ease of installation and maintenance

Built-in maintenance bypass assures continuous power to critical loads during UPS maintenance. Besides, to facilitate installation and maintenance, all panel control and connectors are front accessibility.

Flexible battery configuration adapts different applications

Battery numbers can be adjusted flexibly. It will adapt different power demands and shorten system downtime.

Battery voltage can be set from 32 to 40 pieces per string.

Graphic 5.7” LCD design for easy management

Designed for easy management, Mplus is equipped with

5.7” graphic LCD screen. Intuitive design enhances display information identified and advanced configuration.

High reliable operation with redundant power supply in STS

Mplus provides 2 power supplies in STS. It will ensure no shutdown risk for STS.

User-adjustable charging current

Mplus provides maximum 8A or 6A charging current for every power module and it's user-adjustable based on requirement.

High overload capability

Mplus supports, 110% overload for 60 minutes, 125% for 10 minutes, and 150% for 1 minute.

Standard Series Extended Series

Mplus 30U-90 Mplus 42U-120 Mplus 30U-120 Mplus 30U-180 Mplus 42U-200 Mplus 42U-210 www.fsp-ps.de

LCD Panel Display

YEAR 1:

INITIAL INSTALL

Mplus Series

• Input / Output

• Maintenance Bypass

Breakers

STS Module Includes

Communication Ports

Power Module

Battery Module

YEAR 3:

EXPANSION

Expandability. Flexibility. Uninterruptibility.

Via Modular architecture

Thanks MPLUS Modular design architecture, scalable and compact size 3U rackmount power module that supplies

30kW of backup power protection. Whole system can be easily expanded as your data center growth. Plug and play

N+X,N+1 redundancy design optimizes customer's power demand and enhance the capital investment plan and deployment.

MPLUS smart intelligent load sharing system proportionates workload into each power module without linking any extra communication, paralleled, current share cables. Besides, system is no need to shutdown or interrupt, MPLUS can provide backup support during power module maintenance.

YEAR 5:

FURTHER EXPANSION

29

42U enclosure

30 kW Mplus occupies 3U of space

Total rack space: 15U

Redundant N+1 configuration:

30KW UPS Power modules = 210KW of backup power 7+1, 8 modules share the load equally.

No wiring to extend power module

MPLUS Offers 20KVA and 30KVA power module, no matter which model, e.g, in 30U extend model, power module can be installed up to 6PC, 120KVA with 20KVA or 180KVA with 30kVA 6PC power modules. In addition, same cabinet reduces wiring, or human error operation issue and ensures backup power increased to cover new power demand in a right way.

MPLUS also offers 15U cabinet as economy purpose, full range power rating is not only suitablit for large IT room, Datacenter, but also adquate to infrastructures and different purposes.

MPLUS 30U/42U extremely flexible characteristic, One power module with 30KW unity power factor can be single or multi module operation.

In 42U cabinet model can up to 7+1 modules 210kW, elastic design offers proper backup power protection with appropriate capital investment whenever needed.

15 U 90kW

www.fsp-ps.de

30

Mplus Series

TECHNICAL SPECIFICATIONS

MODEL

PHASE

CABINET CAPACITY*

BATTERY TYPE

Mplus 15U-90

90KW or 60KW

Mplus 30U-90

90KW

Mplus 42U-120

120KW

Mplus 30U-120 Mplus 30U-180

3-phase in / 3-phase out

120KW or 80KW 180KW or 120KW

Mplus 42U-200

200 KW

Mplus 42U-210

210 KW

ONE POWER MODULE CAPACITY

MAX. POWER MODULE NO.

MAX. BATTERY SET NO.**

INPUT

Nominal Voltage

Voltage Range

Nominal Frequency

Frequency Range

Power Factor

PM-20HV : 20KVA/20KW or PM-30HV :

30KVA/30KW

3

3

PM-30HV :

30KVA/30KW

3

3

PM-30HV :

30KVA/30KW

4

5

PM-20HV : 20KVA/20KW or

PM-30HV : 30KVA/30KW

4

-

6

-

3 x 380VAC/400VAC/415VAC

(3Ph+N)

305 ~ 478 VAC at 100% load; 208 ~ 304VAC at <70% load

50/60Hz (Auto Sensing)

40Hz ~70Hz

> 0.99 @ 100% Load , >0.98 @ 50% Load

< 3% @ 100% load

PM-20HV :

20KVA/20KW

10

PM-30HV :

30KVA/30KW

-

8

OUTPUT

Nominal Voltage

Nominal Frequency

Frequency Range (Synchronized)

Overload Capability

3 x 380VAC/400VAC/415VAC (3Ph+N)

± 1% Typical (balanced load) ; ≦ ± 2% Typical (imbalanced load)

50/60Hz

46Hz ~ 54Hz or 56Hz ~ 64Hz

1 hour for 110%, 10 mins for 125%,; 1 min for 150%, 200ms for >150%

2% THD (Linear Load) ; ≦ 4% THD (Non-linear Load)

Up to 94.5%

Max 99% ECO Mode

BATTERY / CHARGER

Nominal Voltage

Maximum Voltage

Minimum Voltage

Float Charging Voltage

Boost Charging Voltage

+/- 216V (12V x 36 pcs)

+/- 240V (12V x 40 pcs)

+/- 192V (12V x 32 pcs)

2.25V / Cell

2.35V / Cell

Yes

8A for 30KW power module

6A for 20KW power module

Maximum Charging Current

(Per Power Module)

PHYSICAL

Cabinet Dimension (D x W x H) mm

Net Weight (Kg)

ENVIRONMENT

8A

1100 x 514 x 763 1100 x 600 x 1475 1100 x 600 x 2010 1100 x 600 x 1475 1100 x 600 x 1475

182 675 932 335 or 333 437.5 or 434.5

IP Class

0 ~ 40°C

0 ~ 95% non-condensing

<1000m for Nominal power

IP 20

MANAGEMENT

RS-232/USB Supports Windows 2000/2003/XP/Vista/2008,Windows 7/8/10, Linux and MAC

Power management from SNMP manager and web browser

STANDARDS

Safety

EMC

IEC/EN 60950-1; IEC/EN 62040-1

IEC/EN 62040-2 Category C3

*When temperature is above 30℃ , the output power factor will be de-rated, 0.9 at 31℃ ~35℃ and 0.8 at 36℃ ~40℃ .

6A 8A

625

1100 x 600 x 2010

549

Model

PM-20HV

PM-30HV

Battery Module

Description

3P/3P 20KVA / 20KW power module

3P/3P 30KVA / 30KW power module

10 pcs of 12V 9Ah batteries

Dimension DxWxH(mm)

650 x 440 x 132 (3U)

650 x 440 x 132 (3U)

735 x 107 x 155

Weight (kg)

34

34.5

26 www.fsp-ps.de

FSP Compact

Series

31

MODEL

1U Lightweight Online UPS

1KVA

Applications:

Security equipement monitoring & control system

Small IT rack system

Network, storage device

1U On-Line UPS Solution

As small rack limitation, FSP compact 1U UPS is the most reliable and trustworthy power guardian. With true double conversion technology(VFI), its avoid annoyed grid issue, e.g. voltage fluctuations, frequency variations, distortion. Easy front battery pack access will be helpful for maintenance check and replacement without removing it from rack mounting.

GENERAL FEATURES

True double conversion online topology

Microprocessor control optimizes reliability

Output power factor 0.8

1U compact size perfect fits for data processing and transmission such as servers, networking and IP telephone services.

Input power factor correction

Converter mode available via software setting

ECO mode for energy saving

Built-in serial communication port/Dry contact

Emergency Power off (EPO) function

32

Compact Series

TECHNICAL SPECIFICATIONS

MODEL

CAPACITY

INPUT

Voltage

Acceptable Voltage Range

Frequency Range

Power Factor

OUTPUT

Output Voltage

Voltage Regulation

Frequency Range (Synchronized Range)

Frequency Range (Batt. Mode)

Current Crest Ratio

Harmonic Distortion

Transfer

Time

AC Mode to Battery Mode

Inverter to Bypass

Waveform (Batt. Mode)

EFFICIENCY

AC Mode

ECO Mode

Battery Mode

BATTERY

Battery Type

Battery Spec & Numbers

Typical Recharge Time

Charging Current

INDICATORS

LED

ALARM

Battery Mode

Low Battery

Overload

Fault

AC INPUT & OUTPUT CONNECTORS

AC Input Connector

AC Output Connector

STANDARDS

Safety / EMC

PHYSICAL

Dimension, (D x W x Hmm)

Net Weight (kgs)

ENVIRONMENT

Humidity

Noise Level

MANAGEMENT

USB or RS-232

CO-1101RS

1000 VA / 800 W

220/230/240 VAC

110-300 VAC @ 50% load

160-300 VAC @ 100% load

40-70 Hz

0.99 @ Nominal voltage (full load)

220/230/240 VAC

± 1%

57 ~ 63 Hz or 47 ~ 53 Hz

60 Hz or 50 Hz ± 0.3 Hz

5:1 (110/120 VAC)

3:1 (220/230/240 VAC)

≧ 3 % THD (Linear Load)

≧ 5 % THD (Non-linear Load)

0ms

4 ms (Typical)

Pure Sinewave

86%

92%

83%

6 V / 9 Ah x 4

9 Hours recover to 90% capacity

1A

Sounding every 4 seconds

Sounding every second

Sounding twice every second

1 x IEC 320 C14

4 x IEC 320 C13

IEC 62040-1 (Safety) / IEC 62040-2 (EMC) / CE

477 x 438 x 44

12.6

20-90 % RH @ 0- 50°C (non-condensing)

Less than 50dB @ 1 Meter

Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MAC

DINRail SERIES

33

DINRail UPS

500VA/1000VA

Applications:

Eqpt. of Mfg

Material

Packing Mgmt

Automation

Control &

Monitoring

Ind. IP-based

Device

Control Panel Solution

FSP DINRail UPS offers a dependable ,cost effective solution to increase equipment stability and system reliability for control panels or different industrial segments. DINRail UPS series with Pure Sine Wave design protects connected devices and guarantees to get through utiliy grid issues, e.g. Under/OverVoltage,

Surge, strike, lighting and outage, these problems will cause industrial processes and manufacturing issue to impact product quality, even safety. Moreover, as

UPS Compact size and front access will allow layout-technican to have more space to design the control panel.

GENERAL FEATURES

Pure Sine Wave

High frequency inverter

Microprocessor controller

Line mode efficiency > 98%

Cold start function

Compact size

DIN rail mounting, Front access

Horizontal or vertical installation

RS485 communication available

Suitable for PLC, I/O controllers, IPC and control panel

34

DINRail Series

TECHNICAL SPECIFICATIONS

MODEL

CAPACITY

INPUT

Nominal Voltage

Acceptable Voltage Range

Frequency

Frequency Range

Line Low Transfer

Line Low Return

Line High Transfer

Line High Return

OUTPUT

Voltage

Waveform

Short Circuit

Protection

Line Mode

Battery Mode

DC Start

Cold Start

TRANSFER TIME

Typical

BATTERY

Battery Voltage

INDICATOR

LED

AUDIBLE ALARM

Battery Mode

Low Battery

UPS Fault

INTERFACE

Communication port

ENVIRONMENT

Operation Temperature

Relative Humidity

PHYSICAL

Dimensions,(WxHxD)mm

Net Weight(Kgs)

Product specifications are subject to change without further notice

Dimension information

Simple & Easy your design

FSP DINRail UPS implements compact design to mount in control panel for more space saving.

The silent service guarantees power quality to protect, to enhance your system functionality and reliability.

Not like traditional UPS, DINRail UPS with front access function solves assembly wiring layout issue and engineer will more flexible to arrange the equipments.

DINRail 500

500VA / 300W

DINRail 1000

1000VA / 600W

220VAC/230VAC/240VAC

170 ~ 270 VAC

50Hz / 60Hz Auto Sensing

63Hz ~ 40Hz

170Vac ± 5%

180Vac ± 5%

270Vac ± 5%

260Vac ± 5%

220VAC/230VAC/240VAC

Pure Sine wave

Circuit Breaker

Electronic Circuit

Yes

2-6 ms ( 10ms max ).

12VDC 12VDC

2.8Kg

AC Mode(Continuously ), Inverter Mode(Flash)

Sounding erery 7 seconds

Sounding every second

Continuously Sounding

RS-485

0-40°C ; 32-104°F

0-90% non-dondensing

250 x 135 x 115

3.2Kg

131.5mm

Max140mm

122.6mm

250mm

Max 142mm

Max 280mm

Max 280mm

Backup Time Table for DINRail Series

500VA

1000VA

Backup Time with Load (Min)

25 % 50 % 75%

50.25

12.0

7.50

12.0

4.47

1.17

100 %

4.52

0.11

iDL SERIES

35

Industrial UPS

10KVA-800KVA

Applications:

Oil & Gas offshore and onshore

Refining and petrochemical

Conventional power generation

Industrial process

Reliable & Dependable Power Solution

FSP iDL industrial UPS designed true double conversion and galvanic isolation with static bypass switch which solves ultimately all types of input power disturbances, such as noise, lightning, and leakage current etc.

Through advanced technology of PWM, DSP and IGBT designed, iDL UPS continually process control and become a high frequency and efficiency product, also choosed the high reliable components which can tolerent & endure extreme power problems to ensure, to offer the best power quality for the protection of industrial mission critical equipments. Product rating range is from 10kVA - 800kVA that can fullfill different industrial segments, heavy-duty, heavy reliability.

GENERAL FEATURES

True Galvanic isolation

Microprocessor DSP design

Multi-CPU design and software/hardware cooperate control Make the system extremely high reliable

Plug & Play modular

Protection against detaching and floating of the neutral

Protection from user error Advanced circuitry prohibits damage to the system

Intelligent charger with temperature compensation

Intelligent, safe battery test circuitry Test

Cold start function

Multiple output sockets

Hot swappable battery function

RS232 communication port

Tel/modem internet surge suppression

Mini- remote control panel (option)

36

iDL Series

True Galvanic isolation

An isolation transformer is placed at the output. This can solve the problem of poor input grounding, can allow a different ground between input and output, can avoid the annoying problem of ground leakage current, and can be tied to any potential provided on site. The AC output is isolated under every mode of operation.

Additionally, the user gets the bonus of attenuation of common mode noise from the output isolation transformer.

High frequency design

The inverter uses high frequency, high efficiency IGBT,

PWM methodology to convert the DC power to AC power. Therefore, the number of components is fewer, reliability is improved, and the size and weight of UPS is reduced, performance is improved, and acoustic noise is minimized.

Cold start function

The UPS can be started without an AC source, that is, can be started with battery power only. This is possible because current limit circuitry is added, preventing the problem of large inrush current blowing the battery fuse and damaging the DC capacitors when batteries are connected to an empty DC bus (before the DC bus is energized).

Plug & Play Modular design

The power circuit is separated into several modules plugged into slots in the UPS, which are easy to pull out, permitting quick maintenance and easier trouble shooting.

Multi-CPU design

Several CPUs are employed in the control circuit, and critical functions are designed with parallel redundancy to improve reliability. Therefore, in case of one CPU failure, the other CPUs keep the UPS operational, and the output AC is not affected.

Intelligent battery test

The batteries are tested after every boost (initiated by battery discharge or by the monthly boost charge cycle).

This is done without interrupting the operation of the rectifier, preventing the risk of output AC failure in case of a bad battery. The user is informed of the battery condition, so that action can be taken before the full capacity of the batteries is needed.

Intelligent charger

The UPS will automatically recharge (boost charge) the batteries every time the batteries are depleted to a voltage level equal to 2V/Cell. Thus, the batteries can be restored to full capacity as soon as possible, and made ready for the next back-up requirement. In order to keep the batteries in the best condition, the UPS will boost charge the batteries for several hours (selectable) automatically every month. To avoid over charging the batteries, boost charge will stop when the ambient temperature is over 35 o

C (95 o

F).

Protection against misuse

The UPS is designed with breaker on/off sensor, power supply sensor, etc. Therefore, any operational mistake made by the user causes no harm to the UPS.

Variety of accessory (options)

With built-in intelligent communication interface as well as output ports of RS-232, RS-485, and dry contacts, there are several options are hence available such as remote control panel, 3 phases software for PC monitoring, auto dialing module, battery monitoring module, 3 phases SNMP card, and emergent power off (EPO) switch. Please refer to the chapter 7 of options for details.

www.fsp-ps.de

iDL Series

TECHNICAL SPECIFICATIONS

MODEL

RECTIFIER

Input Voltage

Input Range

Input Frequency

Input Power Factor

Power Walk In

Efficiency

Voltage Regulation

Ripple Voltage

BATTERY

Battery Type

No. Of Cells

Voltage Range

Battery Low Voltage

Battery Low Stop Voltage

Boost Charge

Float Charge

INVERTER

DC Input Range

Wave Form

Output Voltage

Output Power Factor

Voltage Regulation 100% Unbalance Load

Frequency Lock Range

Output Frequency (Free Running)

Phase Shift Under 100% Unbalance Load

Thd (Linear Load)

Overload

<110%

110 – 124%

125 – 149%

>= 150%

Efficiency (100% Load)

STATIC SWITCH

Voltage Range

Frequency Range

Efficiency

Transfer

Time

- Mains -> Inverter

- Inverter -> Mains

150%

Overload

300%

Isolation With Output

OVERALL CHARACTERISTICS

Overall Efficiency

- Temperature

Operating

Environment

- Humidity

- Altitude

PHYSICAL

Dimension, D X W X H (mm)

Maximum Heat Dissipation(Kw)

Weight(Kg) (No Battery)

STANDARDS

Safety

PROTECTIONS

- Short Circuit

- Lightning

- Emc Filter

- Galvanic Isolation

10

92%

90%

0.65

300

Product specifications are subject to change without further notice

20 30 40 50

380 / 400 / 415VAC 3 Phase 4 Wire (Special spec can be customized)

± 20%

50 / 60 Hz ± 7%

0.8

0% - 100% : 20 sec

99%

1%

0.5%

SEAL LEAD ACID / NiCd

174 / 271

295 – 410VDC / 285-415VDC

320VDC / 305VDC

295VDC / 285VDC

402VDC / 415VDC

390VDC / 410VDC

92%

285 – 420VDC

Sinusoid

380 / 400 / 415 VAC 3 Phase 4 Wire (Special spec can be customized)

0.8

± 1 %

45 – 55 Hz / 55 – 65 Hz

50 / 60 Hz ± 0.1 Hz

120 % + / - 0.5°

< 3 %

Continuous

15 min

5 min

30 sec

93% 93.5% 93.5%

90%

173 – 277 VAC (Line To Neutral)

45 – 55 Hz / 55 – 65 Hz

99.5%

0 ms

0 ms

30 sec

1 sec

YES

91% 91.5%

0 – 40°C ( 32 – 104°F )

0% - 90% ( Non–condensing )

<1500m Above Sea Level

92%

1.3

400

1.9

470

800 x 550 x 1600

2.6

520

3

560

- EN50091-1,-2 & FCC CLASS A

Rectifier, Reserve, Bypass Nfb

Mov

Input & Output

Between Input & Output

60

94%

92%

3.5

630

37 www.fsp-ps.de

38

iDL Series

TECHNICAL SPECIFICATIONS

MODEL

RECTIFIER

Input Voltage

Input Range

Input Frequency

Input Power Factor

Power Walk In

Efficiency

Voltage Regulation

Ripple Voltage

BATTERY

Battery Type

No. Of Cells

Voltage Range

Battery Low Voltage

Battery Low Stop Voltage

Boost Charge

Float Charge

INVERTER

Dc Input Range

Wave Form

Output Voltage

Output Power Factor

Voltage Regulation 100% Unbalance Load

Frequency Lock Range

Output Frequency (Free Running)

Phase Shift Under 100% Unbalance Load

Thd (Linear Load)

Overload

<110%

110 – 124%

125 – 149%

>= 150%

Efficiency (100% Load)

STATIC SWITCH

Voltage Range

Frequency Range

Efficiency

Transfer

Time

Overload

- Mains -> Inverter

- Inverter -> Mains

150%

300%

Isolation With Output

OVERALL CHARACTERISTICS

Overall Efficiency

Temperature

Operating

Environment

Humidity

Altitude

PHYSICAL

Dimension, D X W X H (mm)

Maximum Heat Dissipation(Kw)

Weight(Kg) (No Battery)

STANDARDS

Safety

PROTECTIONS

- Short Circuit

- Lightning

- Emc Filter

- Galvanic Isolation

80

94.5%

94.5%

4.6

950

Product specifications are subject to change without further notice

100 120 160 200 240

380 / 400 / 415VAC 3 Phase 4 Wire (Special spec can be customized)

± 20%

50 / 60 Hz ± 7%

0.8

0% - 100% : 20 sec

99%

1%

0.5%

SEAL LEAD ACID / NiCd

174 / 271

295 – 410VDC / 285-415VDC

320VDC / 305VDC

295VDC / 285VDC

402VDC / 415VDC

390VDC / 410VDC

285 – 420VDC

Sinusoid

380 / 400 / 415 VAC 3 Phase 4 Wire (Special spec can be customized)

0.8

+ / - 1 %

45 – 55 Hz / 55 – 65 Hz

50 / 60 Hz + / - 0.1 Hz

120 % + / - 0.5°

< 3 %

CONTINUOUS

15 min

5 min

30 sec

94.5% 95% 95% 95%

94.5%

5.4

1250

173 – 277 VAC (LINE TO NEUTRAL)

45 – 55 Hz / 55 – 65 Hz

99.5%

0 ms

0 ms

30 sec

1 sec

YES

95%

0 - 40℃ ( 32 - 104℉ )

95%

0% - 90% ( Non–condensing )

<1500 m above sea level

6.5

1400

800 x 1100 x 1600

8.7

1600

- EN50091-1,-2 & FCC CLASS A

Rectifier, Reserve, Bypass Nfb

Mov

Input & Output

Between Input & Output

94%

11.5

2500

95%

94%

800 x 2240 x 1600

13

2700 www.fsp-ps.de

iDL Series

TECHNICAL SPECIFICATIONS

MODEL

RECTIFIER

Input Voltage

Input Range

Input Frequency

Input Power Factor

Power Walk In

Efficiency

Voltage Regulation

Ripple Voltage

BATTERY

Battery Type

No. Of Cells

Voltage Range

Battery Low Voltage

Battery Low Stop Voltage

Boost Charge

Float Charge

INVERTER

Dc Input Range

Wave Form

Output Voltage

Output Power Factor

Voltage Regulation 100% Unbalance Load

Frequency Lock Range

Output Frequency (Free Running)

Phase Shift Under 100% Unbalance Load

Thd (Linear Load)

Overload

<110%

110 – 124%

125 – 149%

>= 150%

Efficiency (100% Load)

STATIC SWITCH

Voltage Range

Frequency Range

Efficiency

Transfer

Time

Overload

- Mains -> Inverter

- Inverter -> Mains

150%

300%

Isolation With Output

OVERALL CHARACTERISTICS

Overall Efficiency

Temperature

Operating

Environment

Humidity

Altitude

PHYSICAL

Dimension, D X W X H (mm)

Weight(Kg) (No Battery)

STANDARDS

Safety

PROTECTIONS

- Short Circuit

- Lightning

- Emc Filter

- Galvanic Isolation

320

95%

92%

800 x 2240 x 1600

3000

Product specifications are subject to change without further notice

400 500 600 700

95%

93%

380 / 400 / 415VAC 3 Phase 4 Wire

± 20%

50 / 60 Hz ± 7%

0.8

15% - 100% : 15 sec

99%

1%

0.5%

Seal Lead Acid / Nicd

174 / 271

295 – 410VDC / 285-415VDC

320VDC / 305VDC

295VDC / 285VDC

402VDC / 415VDC

390VDC / 410VDC

285 – 420VDC

Sinusoid

380 / 400 / 415 VAC 3 Phase 4 Wire

0.8

+ / - 1 %

45 – 55 Hz / 55 – 65 Hz

50 / 60 Hz + / - 0.1 Hz

120 % + / - 0.5°

< 5 %

Continuous

15 min

5 min

30 sec

95% 95%

173 – 277 VAC (Line To Neutral)

45 – 55 Hz / 55 – 65 Hz

99.5%

0 ms

0 ms

30 sec

1 sec

YES

93%

0 - 40℃ ( 32 - 104℉ )

93%

0% - 90% ( Non–condensing )

<1500 m above sea level

95%

93%

1000 x 2220 x 1900

3600

1000 x 3340 x 1900

4500 6000

1000 x 4460 x 1900

7200

- EN50091-1,-2 & FCC CLASS A

Rectifier, Reserve, Bypass Nfb

Mov

Input & Output

Between Input & Output

800

95%

93%

7500

39 www.fsp-ps.de

40

FSP SOLAR POWERMANAGER

OFF-GRID SERIES

Remote

Control Panel

Power Solution for Unstable or without Utility Grid

1kVA-5kVA

FSP Solar PowerManager Off-Gird

An ideal Off-Grid inverter for households, FSP Solar

PowerManager Off-Grid with specific AC and high efficiency MPPT Solar charger built-in, Dual charging sources (utility+solar) up to 140A current satisfying battery charging under different weather conditions and ensuring your power continuously.

Wide input range from 90-280Vac will overcome most of grid power instabilities.

Design as true sine wave off-grid inverter with 1kVA to

5kVA rating, 4/5kVA parallel function up to 30kVA

(single phase) suitable for different applications and supporting 3-Phase power system in anymode. FSP

Solar PowerManager Off-Grid with smart user-friendly control panel is an adjustable power source for optimal settings according to end users needs. The unit also offers USB Port for PC monitoring purpose.

As non-household application, FSP Solar PowerManager

Off-Grid is able to provide power e.g. for a water pump.

GENERAL FEATURES

High frequency pure sine wave

Wide AC input range 90-280 Vac

Solar and AC Dual charger built in

Charging Ability up to 140A (AC+Solar)

Built-in dry-contact for Generator

Double surge capacity of rating

4k/5kVA parallel function support single Phase up to 30kVA

3Phase AnyMode support

Intuitive LCD Display

User friendly LCD Panel control & setting

Source Priority programmable

Remote Control Panel support

User defined Bulk/Float Charging voltage

Free monitoring software

FSP Solar PowerManager Off-Grid Series

TECHNICAL SPECIFICATIONS

MODEL

RATED POWER

INPUT

Voltage

Selectable Voltage Range

Frequency Range

OUTPUT

AC Voltage Regulation (Batt. Mode)

Surge Power

Efficiency (Peak)

Transfer Time

Waveform

BATTERY & AC CHARGER

Battery Voltage

Floating Charge Voltage

Overcharge Protection

SOLAR CHARGER & AC CHARGER

Maximum PV Array Power

MPPT Range @ Operating Voltage

Maximum PV Array Open Circuit Voltage

Maximum Solar Charge Current

Maximum AC Charge Current

Maximum Charge Current

Maximum Efficiency

Standby Power Consumption

PHYSICAL

Dimension, D x W x H (mm)

Net Weight (kgs)

Ingress Protection Rating

Cooling system

OPERATING ENVIRONMENT

Humidity

Operating Temperature

Storage Temperature

PM-OffGrid 1K-24 PM-OffGrid 1K-48 PM-OffGrid 2K-24 PM-OffGrid 3K-24 PM-OffGrid 3K-48

1000VA/800W 1000VA/1000W 2000VA/1600W 3000VA/2400W 3000VA/2400W

PM-OffGrid 4K PM-OffGrid 5K

4000VA/3200W 5000VA/4000W

24 VDC

27 VDC

31 VDC

600 W

30VDC~ 66VDC

75VDC

25A

20A

45A

2000VA

90%-93%

230 VAC

170-280 VAC (For Personal Computers)

90-280 VAC (For Home Appliances)

50 Hz/60 Hz (Auto sensing)

230VAC ± 5%

4000VA

6000VA

93%

10 ms (For Personal Computers); 20 ms (For Home Appliances)

Pure sine wave

8000VA

48 VDC

54 VDC

62 VDC

24 VDC

27 VDC

31 VDC

24 VDC

27 VDC

31 VDC

900 W 600 W 600 W

60VDC~ 88VDC

75VDC

30VDC~ 66VDC

75VDC

30VDC~ 66VDC

75VDC

18A

15A

25A

30A

25A

30A

33A 55A 55A

AC charger and solar charger can’t work at the same time

98%

2 W

48 VDC

54 VDC

62 VDC

900 W

60VDC~ 88VDC

102VDC

18A

15A

33A

10000VA

48 VDC

54 VDC

60 VDC

48 VDC

54 VDC

60 VDC

4000 W

60VDC~ 115VDC

145VDC

80A

60A

140A

4000 W

60VDC~ 115VDC

145VDC

80A

60A

6.8

100 x 272 x 355

7

IP20

AirForce cooling

7.4

5% to 95% Relative Humidity(Non-condensing)

0°C - 55°C

-15°C - 60°C

120 x 295 x 468

11

MODEL

RATED POWER

INPUT

Voltage

Selectable Voltage Range

PM-OffGrid 2K-24+

2000VA/1600W

Frequency Range

OUTPUT

AC Voltage Regulation (Batt. Mode)

Surge Power

Efficiency (Peak)

Transfer Time

Waveform

BATTERY & AC CHARGER

Battery Voltage

Floating Charge Voltage

Overcharge Protection

SOLAR CHARGER & AC CHARGER

Maximum PV Array Power

MPPT Range @ Operating Voltage

Maximum PV Array Open Circuit Voltage

Maximum Solar Charge Current

Maximum Efficiency

Standby Power Consumption

24 VDC

27 VDC

31 VDC

1500 W

60VDC~ 115VDC

PHYSICAL

Dimension, D x W x H (mm)

Net Weight (kgs)

Ingress Protection Rating

Cooling system

OPERATING ENVIRONMENT

Humidity

Operating Temperature

Storage Temperature

Product specifications are subject to change without further notice

PM-OffGrid 2K-48+

2000VA/1600W

230 VAC

PM-OffGrid 3K-24+

3000VA/2400W

170-280 VAC (For Personal Computers)

90-280 VAC (For Home Appliances)

50 Hz/60 Hz (Auto sensing)

230VAC ± 5%

4000VA

6000VA

90%-93%

10 ms (For Personal Computers); 20 ms (For Home Appliances)

Pure sine wave

48 VDC

54 VDC

62 VDC

3000 W

60VDC~ 115VDC

145VDC

60A

98%

2W

140 x 295 x 479

11.5

IP20

AirForce cooling

5% to 95% Relative Humidity(Non-condensing)

0°C - 55°C

-15°C - 60°C

24 VDC

27 VDC

31 VDC

1500 W

60VDC~ 115VDC

PM-OffGrid 3K-48+

3000VA/2400W

48 VDC

54 VDC

62 VDC

3000 W

60VDC~ 115VDC

41 www.fsp-ps.de

www.fsp-solar.de

42

FSP Solar PowerManager Off-Grid Series

Programmable Power Source Priority function.

More Flexible, More Independent for energy usage and storage.

The Principle of FSP Solar PowerManager Off-Grid

As Hybrid Power System As Power backup System

Solar Power Solar Power

Generator Utility Generator Utility

SLS Battery Home Appliance SLS Battery Home Appliance

FSP Solar PowerManager Off-Grid Smart Power Priority

Power and charging source priority of FSP Solar PowerManager Off-Grid smart design can be set up by the front LCD panel according to the power consumption environment, storing and withdrawal of energy are also user-defined.

O/P Source Priority

1 2 3

Output source Priority is Solar-> Bat-> Utility

Charging source priority is Solar Power Only

Solar energy is sufficient to charge the battery and carry the loads. Once solar power is low, system will switch to battery mode automatically until battery reaches low warning then system transfers to utility.

Output source is Utility first

Charging source priority is solar first

Utility will feed output loads, Solar power will charge the battery until solar power ceases. Solar and battery energy will be used when utility fails.

Power source priority is Utility -> Solar & Battery

Charging source priority is Solar -> Utility www.fsp-ps.de

www.fsp-solar.de

FSP Solar PowerManager Off-Grid Series

Single Phase Parallel and 3-Phase AnyMode

High expansion ability: FSP Solar PowerManager Off-Grid 4kVA and 5kVA design can be expanded to 30kVA in parallel mode, single phase, and also specifically supports 3 Phase AnyMode. The Power capacity can satisfy most of household energy demand.

Parallel 3 units in Single Phase

Up to 30kVA parallel ability: FSP Solar

PowerManager Off-Grid will achieve expansion function by parallel kits in order to get more power capacity. (The drawing presents 3 units in parallel mode, power capacity is 15kVA.)

Parallel 6 units in 3 Phase AnyMode

FSP Solar PowerManager Off-Grid supports

3 Phase AnyMode. By consulting and measurement user can define which phase needs more power support, e.g. P1 = Phase

1 is consuming most of the power in the house, system can install Max 4 PC in L1 to get 20kVA power.

Battery

Utility

Load

N

L

N

L

Phase 1=P1 P2 P3

43

Battery

N

Utility

Load

L1

L2

L3

L1

L2

L3

N

Output source & Charger source priority is solar first

When Solar energy is sufficient to charge the battery and feed the loads, utility will stand by until Solar power ceases or battery voltage drops to user’s setting.

Power source priority is Solar -> Battery or Utility

Charging source priority is Solar -> Utility

Output source is Solar-Bat-Utility

Charging source priority is Solar & Utility (4/5k only)

System will adapt Solar and utility both source to charge battery at the same time. Once solar power is low, system will switch to battery mode automatically until reach low bat warning then transfer to utility.

Power source priority is Solar -> Battery -> Utility

Charge source priority is Solar & Utility www.fsp-ps.de

www.fsp-solar.de

44

FSP SOLAR POWERMANAGER

HYBRID SERIES

Smart Energy for Smart Home

FSP Solar PowerManager-Hybrid

Offers a more intelligent power solution for our customers to reduce the energy bill and make a contribution to our homeland, to our earth. Your energy can be used as efficiently, as smart as possible under current power consumption environment.

YOUR ENERGY, YOU DECIDE!

By the unique optimum technology of FSP Solar

PowerManager-Hybrid Series you can control whether or how to use your energy, to store the generated power into battery or feed into the grid. Moreover, if grid power failed, by the brilliant ability of FSP Solar

PowerManager-Hybrid Series, the load will be handled smartly by direct support from solar, by combining solar

& storage energy or withdrawing storage power only.

Multiple communication methods for different applications: FSP Solar PowerManager-Hybrid Series implements USB, RS232 ports and also fits with intelligent slot for SNMP card monitoring or Modbus Card for smart meter compensation applicable to keep your electricity meter at zero. to stay your electricity meter at zero.

3KW-10KW

GENERAL FEATURES

Just ONE integrated design of Grid-tied & Off-Grid function

Solar PowerManager-Hybrid implements AC I/P breaker and DC switch

Solar Energy Storage

Optimized Self-Consumption

Load Dual-compensated: Solar & Storage Power or Grid

& Storage Power

Power securing during Grid Failure

Back-up function

Intuitive LCD Display

SNMP, Modbus AS400 Support

Certified VDE0126 & VDE4105

5kW&10kW Model Parallel function available, up to 6PC

1

3

2

4

FSP Solar PowerManager-Hybrid Series

45

1. Solar Panel

2. FSP Solar PowerManager-Hybrid

3. SLS Battery

4. MBS:Maintenance Bypass Switch

Multi-Operation Mode

Solar Energy Multi-Use

Intelligent design adding more options to use

Solar Energy: It is not just conventional PV inverter Feed-in function, the system with sufficient solar power will not only feed in grid, but also store energy and support loads.

Self-Consumption

When Solar Energy is low e.g. at night, the FSP

Solar PowerManager will automatically withdraw the power from Energy storage

(Battery) without using power from utility; saving & reducing your energy bill.

Back-up Power when Grid Outage

FSP Solar PowerManager implements off-grid inverter function. If a utility failure or outage occurs, the system will switch to back-up mode and offer continuous power.

www.fsp-ps.de

www.fsp-solar.de

46

FSP Solar PowerManager-Hybrid Series

Manage Your Own Power

FSP Soalr PowerManger - Hybrid is an ingenious design unit. Product achieves tri-power source, Solar, Utility, and Battery Management.

Home Appliance

Solar Power

Monitoring System

SLS Battery

Socket & Emergency Lighting

Energy Meter

FSP Solar PowerManager-Hybrid Compensation Mode:

Modbus Card for smart meter compensation applicable to keep your electricity meter at zero.

All the loads are connected with Grid FSP Solar PowerManager-Hybrid which is an auxiliary power. At daytime, Solar Power is sufficient to feed in grid and store energy at the same time.

At nighttime, FSP Solar PowerManager-Hybrid will withdraw the power constantly from the battery providing energy to your home appliances in order to decrease your energy bill.

If a utility outage occurs, FSP Solar PowerManager-Hybrid will generate the back-up power for emergency demand, e.g. lighting which is connected to the unit.

www.fsp-ps.de

www.fsp-solar.de

FSP Solar PowerManager-Hybrid Series

47

TECHNICAL SPECIFICATIONS

MODEL

PHASE

MAXIMUM PV INPUT POWER

RATED OUTPUT POWER

MAXIMUM CHARGING POWER

MAXIMUM CHARGING POWER

PowerManager-Hybrid 3kW

PV INPUT

Nominal DC Voltage / Maximum DC Voltage

Start-up Voltage / Initial Feeding Voltage

MPP Voltage Range

Number of MPP Trackers / Maximum Input Current

GRID OUTPUT

Nominal Output Voltage

Output Voltage Range

Nominal Output Current

Power Factor

EFFICIENCY

Maximum Conversion Efficiency (DC/AC)

European Effi[email protected] Vnominal

HYBRID / OFF-GRID OPERATION

4500 W

3000 W

1200 W

360VDC / 500VDC

116VDC / 150VDC

250VDC / 450VDC

1/1 x 18A

208/220/230/240VAC

13 A

> 0.99

96 %

95 %

PowerManager-Hybrid 4kW

Single phase

5000 W

4000 W

4000 W

360VDC / 580VDC

116VDC / 150VDC

280VDC / 500VDC

1/1 x 18A

202/208/220/230/240VAC

184 - 265 VAC*

17.5 A

93 %

95 %

PowerManager-Hybrid 5kW

> 0.99

10000 W

5000 W

4800 W

720VDC / 900VDC

225VDC / 250VDC

250VDC / 850VDC

2/2 x 10A

208/220/230/240VAC

21 A

96 %

95 %

PowerManager-Hybrid 10kW

3-phase in / 3-phase out

14850 W

10000 W

9600 W

720VDC / 900VDC

320VDC / 350VDC

400VDC / 800VDC

2/2 x 18.6A

230VAC(P-N) /400VAC(P-P)

184-265 VAC* per phase

14.5A per phase

96 %

95 %

PV INPUT

Nominal DC Voltage /Maximum DC Voltage

Start-up Voltage / Initial Feeding Voltage

MPP Voltage Range

Number of MPP Trackers / Maximum Input Current

GRID OUTPUT

Nominal Output Voltage

Output Voltage Range

Nominal Output Current

AC INPUT

360VDC / 500VDC

116VDC / 150VDC

250VDC / 450VDC

1/1 x 18A

13 A

360VDC / 580VDC

116VDC / 150VDC

280VDC / 500VDC

1/1 x 18A

202/208/220/230/240VAC

184 - 264.5 VAC*

17.5 A

720VDC / 900VDC

225VDC / 250VDC

250VDC / 850VDC

2/2 x 10A

21 A

720VDC / 900VDC

320VDC / 350VDC

400VDC / 800VDC

2/2 x 18.6A

230VAC(P-N) /400VAC(P-P)

184-264.5 VAC* per phase

14.5A per phase

AC Start-up Voltage/Auto Restart Voltage

Acceptable Input Voltage Range

Maximum AC Input Current

BATTERY MODE OUTPUT

Nominal Output Voltage

Efficiency (DC to AC)

BATTERY & CHARGER

Nominal DC Voltage

30 A

93%

120 - 140 VAC / 180 VAC

170 - 280 VAC

40 A

202/208/220/230/240VAC

91%

40 A

93%

120-140VAC per phase /

180VAC per phase

170-280 VAC per phase

40 A

230VAC(P-N) /400VAC(P-P)

91%

Maximum Charging Current

30 A

48 VDC

80 A

48 VDC

Default 60A, 5A-100A

(Adjustable)

Default 60A, 10A-200A

(Adjustable)

GENERAL

PHYSICAL

Dimension, D x W x H (mm)

Net Weight (kgs)

INTERFACE

Communication Port

Intelligent Slot

ENVIRONMENT

Humidity

Ingress Protection Rating

Cooling system

Operating Temperature

Altitude

107 x 438 x 480

15.5

RS-232 / USB

117 x 438 x 535

16.2

204.2 x 460 x 600

29

Optional SNMP, Modbus, and AS-400 cards available

167.5 x 500 x 622

RS-232/USB and CAN Interface

45

0% - 95% RH (No condensing) 0% - 90% RH (No condensing)

IP20

AirForce cooling

0 to 40°C

0 ~ 1000 m** Max2000m

0% - 95% RH (No condensing)

-10 to 55°C

*These figures may vary depending on different AC voltage and country requirements.

* * Power derating 1% every 100 m when altitude is over 1000m.

* Product specifications are subject to change without further notice www.fsp-ps.de

www.fsp-solar.de

48

SCC-MPPT

Applications:

ECO

Solar Input Flexible installation

Battery charger

CO

2

Free

98% Efficiency Solar Charger

SCC-MPPT Solar Charge Controller With advanced maximum-power-tracking technology, SCC-MPPT series ensures maximum performance from your solar array at all times and in all weather conditions.

Solar Charger Controller

3KW

GENERAL FEATURES

Intelligent Maximum Power Point Tracking technology

Built-in DSP controller with high performance

12/24/48V Automatic battery voltage detection when initial

Battery temperature compensation support

Three-stage charging optimizes battery performance

Multifunction LCD displays detailed information

Reverse polarity protection for solar panel and battery

Overcharge protection

Suitable for battery types of sealed lead acid, vented

Gel, and NiCd

SCC-MPPT

TECHNICAL SPECIFICATIONS

MODEL

INPUT

MPPT Range @ Operating Voltage

Maximum PV Array Open Circuit Voltage

Maximum PV Array Power

Maximum Current

OUTPUT

Nominal Battery Voltage

Connected Battery Type

800W

SCC-MPPT 3KW

60 VDC ~ 115 VDC

145VDC

1600W

50 A

3200W

12 VDC 24 VDC

Sealed lead acid, AGM or Gel

48 VDC

Maximum Charging Current

Maximum Efficiency

60 A

98%

Charging Method

PROTECTION

Overload Protection

Three stages: bulk, absorption, and floating

Overcharge Protection

> 110% : audible alarm

Yes

Polarity Reversal [email protected] Cell & Battery

INDICATORS

LCD Panel

LED Display

Yes

LCD panel indicating solar power, load level, battery voltage/capacity, charging current, and fault conditions

Three indicators for solar, charging, and load status

PHYSICAL

Dimension, D x W x H (mm)

Net Weight (Kgs)

Type of Mechanical Protection

ENVIRONMENT

Humidity

Operating Temperature

Storage Temperature

Altitude

Product specifications are subject to change without further notice

315 x 165 x 128

4.5

IP 31

5 ~ 95% RH (Non-condensing)

0°C to 55°C

-15°C to 60°C

0 ~ 3000 m

49

Standalone Solar Power System:

Combined MPPT technology and DSP controller,

FSP Solar charger controller will convert best voltage and power to charge battery based on varied temperature.

Compared to traditional solar charge controllers, it allows your solar panels to operate at their optimum power output voltage, providing higher efficiency up to 98% with lower power loss.

Integrated FSP Solar charger controller with inverter, solar panel, and external battery packs, it can become a standalone solar power system to generate green power for your home appliances.

External battery packs

SCC-MPPT

Inverter

Solar panel

Home appliances www.fsp-ps.de

www.fsp-solar.de

50

Accessory

Synergy Super Charger

• Isolation design for 24/36/48/72/240VDC System

• Input power factor correction

• Microprocessor guarantee smart & stable three-stage charging

• User-adjustable charging current based on applications

• Output short circuit protection

• Maximum current restriction

• Over-voltage protection

• Thermal control protection and reversal polarity protection

• Parallel operation

PDU & Maintenance Bypass Switch

• 1-3 kVA Tower/Rack PDU & MBS

• 16A for 208/220/230/240 VAC

• Provides continuous power to connected equipment during UPS maintenance

• Easy operation with simple rotary switch and indicators

• Simple installation with plug-and-play socket type

AC input 1x IEC C20 (16A) connector

UPS I/P 1x IEC C19 (16A) connector

UPS O/P 1x IEC C20 (16A) connector

O/P Socket 5 x IEC C13 + 1x IEC C19, 2 breakers

External Maintenance Bypass Switch

• 6-10kVA Rack MBS

• 63A. max input current 

• 100% make before break to provide continuous power to connected equipment

during UPS maintenance 

• Automatic UPS-protection design

• Easy operation with simple rotary switch

• Terminal block type

30kVA Wall-Mounted External Maintenance Bypass

• 3-Phase design

• Nominal current 63A

• Isolation Voltage 660VAC

• EN90647-3:2009+A1 TUV certificated

IEC Cable 16A C19/C20 (180cm) IEC Cable 16A C20/C13 (180cm) IEC Cable 16A C14/C19 (150cm)

Rackmount Slider

Simple installation for mounting Rack in your server rack enclosure.

RMS-001 for 1-3kVA Rack UPS

RMS-002 for 6-10kVA Rack UPS

Software

ViewPower - UPS Management Software

ViewPower Pro is UPS management software which is perfect for home users and enterprises. It can monitor and manage from one to multiple UPSs in a networked environment including LAN, INTERNET and Modbus networks. Integrated with

Shutdown Wizard, it can not only prevent data loss from power outage and safely shutdown systems, but also store programming data and scheduled shut down UPSs.

All UPS working data and event records can be kept in local database system.

www.fsp-ps.de

www.fsp-solar.de

Accessory

UPS Remote Monitoring and Connectivity

FSP provides complete connectivity solutions with comprehensive products and software package. These connectivity products ensure communication compatibility with a variety external devices through relay, SNMP and Modbus.

Connects to

Environmental

Monitoring Device

LAN

Router

SNMP

Router

LAN

WAN

5Vdc DC input

WWW

WAN

WWW

Connectivity Product

SNMP Card

SNMP Web Card

(DP801B)

Modbus Card

SNMP Web Card

SNMP Web Box

Modbus Web Card

SNMP Web Card/Box

• Allows control and monitoring of multiple inverters through RJ-45 network

connection

• Real-time dynamic graphs of UPS / PowerManager data

• Warning notifications via audible alarm, broadcast, mobile messenger, e-mail and

SNMP traps

• Historic data log stored in centralized PC database

• Simple firmware upgrade with one click

• Password security protection and remote access management

• Supports optional environmental monitoring detector for temperature, humidity

and smoke

Modbus Card

• Real-time control and monitoring of multiple inverters via RS-485 communication port

• Supports Modbus RTU protocol

• Provides MODBUS functions including read Holding Registers and write Registers

• Provides surge protection

Modbus Web Box

• Supports to monitor off-grid inverter through modbus interface

• Implements MODBUS RTU protocol

• Integrated with WatchPower software

• Supports PowerManager Hybrid series

Relay Card

The AS400 communication card provides contact closures for remote monitoring UPS.

To meet different application requirement, the AS400 card is capable of selection the status of the dry-contact signal (active close or active open) by setting jumper.

DB9 Port

EMD

9-pin Port

Energy meter

Environmental Monitoring Device (EMD)

• Plug & use for simple installation with SNMP manager

• Monitor temperature and humidity to protect your precious equipment

• Allow 4 contact closure signals for user-defined usage

• Management software to remote monitor temperature and humidity status via web browser

• Measure temperatures between 0 to 100°C with an accuracy of ±1.5°C

• Measure relative humidity between 10 to 90% RH with an accuracy of ±3%

• Optional smoke alarm available

Touch screen 3-phase multi-function meter

Measures and displays the parameter of voltage,frequency,current, active and reactive energy,imported or exported. Max Demand,THD of voltage and current can be meaured over present periods of up to 60 minute. Built-in interfaces provide pulse and

RS485 Modbus RTU output

51

Software

SolarPower -Solar inverter Management Software

SolarPower is a solar inverter monitoring software. It can monitor multiple devices via

USB and Serial port at the same time. The major functions of SolarPower monitoring software include data log for devices, power generation statistics, alarm messages, fault messages and parameter setting for devices.

www.fsp-ps.de

www.fsp-solar.de

Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement

Table of contents