Turbine Flow Sensors

Turbine Flow Sensors
Flo-tech
by
®
Turbine Flow Sensors
Simultaneously Measure Flow Rate, Pressure and Temperature.
Offered with US (SAE) or Metric (BSPP) Ports.
1-800-433-5263
Table of Contents
Description
Page
General Design Features
2
Activa Sensor Array
3-4
Ultima Sensor Array
5-6
Turbine FLow Sensors
7-10
XLI Digital Displays
11-12
XLF Digital Displays
13-14
Portable Hydraulic Testers
15-16
Sensor Array with Load Valve
17-18
SIM-Check®
19-22
F6301 Pressure Sensor
23-24
F5130, SWI-5, Square Wave Interface
25
F6310, Temperature Sensor with 4-20 mA outputs
26
Connecting Cable Chart
27
Common Conversion
28
Notes
29
Mail to:
Flo-tech by Hedland
Division of Racine Federated Inc.
PO Box 044780
Racine, WI 53404-7017
Ship to:
Flo-tech by Hedland
Division of Racine Federated, Inc.
2200 South Street
Racine, WI 53404
E-mail:
[email protected]
[email protected]
[email protected]
Customers within the United States, Canada
and U.S. possessions:
Call Toll-Free: 1-800-HEDLAND
(800-433-5263)
Fax Toll-Free: 1-800-CHK-FLOW
(800-245-3569)
International Customers:
Phone: 262-639-6770
Fax: 262-639-2267
Monday - Friday from 8 a.m. to 5 p.m. CST
Web-site: http://www.flo-tech.com
1 TEL.1-800-433-5263 CALL FOR AUTHORIZED DISTRIBUTOR IN YOUR AREA
General Design Features
1 – Housing
2 – Turbine rotor
3 – Rotor Supports
4 – Lock Nut
5 – Magnetic Pickup (frequency output)
6 – Signal Converter (4-20mA output)
7 – Pressure Port Adapter
8 – Temperature Port Adapter
9 – Retainer Rings
➅
➄
➂
➁
➃
➀
➈
OPERATING PRINCIPLE
Turbine flow sensors measure the flow rate of hydraulic fluid and
compatible liquids. As fluid flows through the sensor it turns the
turbine rotor, and as each turbine blade passes the magnetic pickup
an electrical signal is generated. This frequency signal is proportional
to the flow rate and can be transmitted to Flo-tech’s digital displays
or converted to a 4-20mA output. Optional sensors allow
measurement of pressure, temperature, and speed.
Rugged construction: Flow sensors are constructed in anodized
aluminum* with SAE, BSPP, Code 61 and Code 62, 4-bolt flanged
ports. The sensor arrays have a forward flow accuracy of +/-1% full
scale, fluid temperature range of -4 to 300°F, and are available in
pressure ratings up to 6000 psi.
➀
➃
➆
➈ ➂
➇
➁
Flow straighteners: While flow straighteners are manufactured into
each sensor, it is recommended that at least 10 port diameters of
upstream pipe with no obstructions to the flow sensor and at least
5 port diameters downstream pipe be provided to obtain laminar flow.
Filtration: All applications should be filtered to at least 40 micron.
Placing the flow sensor at a higher elevation in the system will avoid
collection of debris, sediment, and dirt in the sensor.
Viscosity: As long as the fluid viscosity remains within a range of
50-500 SUS or 10 cST to 100 cST, the flow sensors will stay within
the +/-1% of full flow specifications.
Accuracy: The sensor arrays have a forward flow accuracy of +/-1%
full scale while monitoring hydraulic liquids with viscosity and specific
gravity similar to factory calibrated fluids.
Calibration: Flow meters are calibrated with 0.876 specific gravity,
140 SUS (32 cST) hydraulic oil, irrespective of final fluid use. Standard
calibration is done using 3-points however, 5- and 10-point calibration
certification is also available. If accuracy greater than 1% is required,
please consult factory. This can be accomplished through additional
calibration measures.
Linearization: Flo-tech flow sensors are linear which provides a
significant increase in accuracy. The output of the flow sensor varies
by the same percentage as the flow through the meter.
Repeatability: Flow meter repeatability is within +/- 0.2%. This is
particularly important in cylical applications which require consistent
readings.
Bi-directional flow capability: Turbine flow sensors are inherently
bi-directional, as the turbine will function normally in reverse condition.
Flo-tech does not guarantee accuracy in reverse flow, however, it is
generally in the range of +/-1.5% to +/-2% of full scale. If required,
a reverse flow calibration is optional.
* Portable testers constructed in cold-rolled steel. 6013-T651/FSD series in zinc-plated,
stress-proof steel.
LEARN ABOUT OTHER DIVISIONS‘ PRODUCTS FAX: 1- 800- 245-3569 2
Activa Sensor Array
Series
F6200A
/
F6220A
Simultaneously Measures Flow, Pressure and Temperature
• Four flow ranges
• Turbine Flow Measurement
• Pressures up to 5800 psi
• Temperatures up to 300° F
• Three sensors - one line break
• 4-20 mA sensor outputs
The Activa Sensor Array provides flow,
temperature and pressure signals in a compact
unit that requires only one hydraulic line break.
Each sensor transmits a 4-20 mA output signal
that is easily integrated with PCs, PLCs,
recorders or panel displays. Signals can also
be transmitted to Flo-tech XLI displays or the
SIM-Check hydraulic system analyzer.
Typical applications include fluid characteristic
measurement on test stands, stationary
hydraulic system monitoring, feedback for
hydraulic system control, advance warning of
impending component failure and mobile
hydraulic system diagnosis.
Bulletin #512
SPECIFICATIONS:
MATERIAL:
Housing: 6013-T651 Anodized aluminum Ball Bearings: 440 C Stainless steel
Adapters: 6061-T6 Anodized aluminum Hub Cones: 6061-T6 Aluminum alloy
Turbine Rotor: T416 Stainless steel
Retainer Rings: 6061-T6 Aluminum alloy
Rotor Supports: 6061-T6 Aluminum;
Seals: Buna N standard; Viton and
C360 Brass for models F6202-A
EPR optional
and F6222-A
Rotor Shaft: T303 Stainless steel
PORTS: SAE J1926/1, BSPP ISO1179
MAGNETIC PICK-UP: Body – 12L14 steel, black oxide finish
Lock Nut – 12L14 steel, zinc plate, dichromate finish
SIGNAL CONVERTER: Body – Nickel-plated 6061-T6 aluminum
Connectors – Nickel-plated brass
Electrical:
Circuit Power Requirement: Load + 7.0 mA
Excitation Range: 6 – 28 VDC
Accuracy: ±0.5% of full scale span, plus
Output Current Range: 4 – 20 mA
accuracy of input source
Minimum Load Resistance: 10 ohms
Thermal Drift: ≤ 0.05% F.S. /° F
Maximum Load Resistance:
Excitation Voltage –1V
.02
PERFORMANCE:
Forward flow accuracy: ±1% of full scale
± 0.5% of rate when used with XLI display.
Repeatability: ± 0.2%
Pressure rating: 5800 psi (400 bar) maximum, 5000 psi (345 bar) maximum for
models F6208-A and F6228-A
Pressure drop: See ∆ P charts.
Turbine response: < 200 ms
Fluid temperature range: -4° to 300° F (-20° to 150° C)
Ambient temperature range: -4° to 131° F (-20° to 55° C)
BI-DIRECTIONAL FLOW: Optional calibration available
1 – Common
2 – 4-20 mA output
3 – +VDC
2
3
D
1
DIMENSIONS:
Signal
Converter
A
SERIES
Magnetic
Pickup
Pressure Port
Adapter
Housing
Temperature
Port Adapter
C
B
A
B
C
D
WIDTH
in (mm)
LENGTH
in (mm)
HEIGHT
in (mm)
W/MAG
in (mm)
WEIGHT
(lbs)
F6202-A
F6222-A 1.23 (31.2) 4.72 (120.0) 1.47 (37.3) 5.74 (145.6)
1.60
F6204-A
1.48 (37.6) 5.08 (129.0) 1.80 (45.7) 6.04 (153.0)
F6224-A
1.90
F6206-A 1.98 (50.3) 5.87 (149.0) 2.20 ( 56.0) 6.50 (164.0)
F6226-A
2.80
F6208-A
F6228-A 2.46 (62.5) 6.81 (173.0) 2.48 (63.0) 6.74 (171.0)
4.20
3 TEL.1-800-433-5263 L E A R N A B O U T O U R C A L I B R AT I O N S E R V I C E S
Activa Sensor Array
Series
F6200A
/
F6220A
Simultaneously Measures Flow, Pressure and Temperature
ORDERING INFORMATION:
NOMINAL
PORT SIZE
SAE 8
SAE 12
SAE 16
SAE 20
G 1/4
G 3/4
G1
G 1-1/4
PRESSURE DROP PSI (BAR)
50% MAX FLOW 100% MAX FLOW
10.0 (0.69)
26.0 (1.79)
9.0 (0.62)
25.0 (1.72)
9.0 (0.62)
30.0 (2.07)
8.0 (0.55)
30.0 (2.07)
10.0 (0.69)
26.0 (1.79)
9.0 (0.62)
25.0 (1.72)
9.0 (0.62)
30.0 (2.07)
8.0 (0.55)
30.0 (2.07)
FLOW RATE
0.4 - 7 GPM
2 - 40 GPM
4 - 80 GPM
8 - 160 GPM
1.5 - 26 LPM
7.5 - 151 LPM
15 - 302 LPM
30 - 605 LPM
MODEL
SEALS
F6202 – A
F6204 – A
F6206 – A
F6208 – A
F6222 – A
F6224 – A
F6226 – A
F6228 – A
B*
SENSOR PORTS
TEMPERATURE
PRESSURE
N*
S*
*Basic
Model
*Basic Model
The 4-20mA electronics can be set to either “sink or source.” If the “load sink” is
specified, the load sensing resistor is connected to the positive side of the excitation
voltage. If “load source” is specified, the load sensing resistor is connected to the
negative side of the excitation voltage. If ordered as part of a sensor array, the above
specification is sufficient. If not specified, the 4-20mA signal will be “current
sourcing”, using 600 ohms at 24 VDC.
Seals
B Buna N
V Viton
E EPR
When using Activa Sensor Array with Flo-tech’s XLI Digital Displays, use F6234-6,
6-ft. or F6234-15, 15-ft. connecting Cables on page 27.
T
N
S
G
D
Temperature
with Sensor
1/4 NPTF (F) Plugged
SAE #2 (J514) Plugged
G 1/4 (F) Plugged
SAE #4
Five or Ten Point Calibration Certificates are available.
Flo-tech P.N.
Description
F001109
Five Point Calibration Certificate
F001110
Ten Point Calibration Certificate
These certificates are traceable to NIST, ISO 9001/ANSI Z540-1 &
MIL-STD 45662A
( Example ) F6204 – A B - T 6
Ordering Example:
F6204 - A B-T6, SAE 16, 2-40 gpm with Buna N seals, temperature sensor and 6000 psi pressure sensor.
1
3
5
6
N
S
F
Pressure
1000 psi (69 bar) Sensor
3000 psi (207 bar) Sensor
5000 psi (345 bar) Sensor
6000 psi (414 bar) Sensor
1/4 NPTF (F) Plugged
SAE #2 (J514) Plugged
G 1/4 (F) Plugged
THE ACTIVA SENSOR ARRAY PRESSURE DROP CHART
6
100
F6202
F6204
F6206 F6208
F6222
F6224
F6226 F6228
PRESSURE DROP BAR
PRESSURE DROP PSI
1.0
10
1
.1
.01
.006
.1
.1
1
10
FLOW GPM
100
300
.3
10
100
1000
FLOW LPM
CALL TO DISCUSS YOUR SPECIFIC APPLICATION FAX: 1- 800- 245-3569 4
Ultima Sensor Array
Series
F6200F
/
F6220F
Simultaneously Measures Flow, Pressure and Temperature
• Four flow ranges
• Turbine Flow Measurement
• Pressures up to 5800 psi
• Temperatures up to 300° F
• Three sensors - one line break
The Ultima Sensor Array provides flow,
temperature and pressure signals in a compact
unit that requires only one hydraulic line break.
The magnetic pickup generates a frequency
output and the pressure and temperature
sensors transmit a 4-20 mA output signal
that is easily integrated with PC’s, PLC’s,
recorders or panel displays. The signals can
be transmitted to Flo-tech’s XLF & XLI digital
displays or any other instruments that accept
a frequency or 4-20 mA signal.
Typical applications include fluid characteristic
measurement on test stands, stationary
hydraulic system monitoring, feedback for
hydraulic system control, advance warning of
impending component failure and mobile
hydraulic system diagnosis.
Bulletin #513
SPECIFICATIONS:
MATERIAL:
Housing: 6013-T651 Anodized aluminum
Adapters: 6061-T6 Anodized aluminum
Turbine Rotor: T416 Stainless steel
Rotor Supports: 6061-T6 Aluminum; C360 Brass for models F6202-A and F6222-A
Rotor Shaft: T303 Stainless steel
Ball Bearings: 440 C Stainless steel
Hub Cones: 6061-T6 Aluminum alloy
Retainer Rings: 6061-T6 Aluminum alloy
Seals: Buna N standard; Viton and EPR optional
PORTS: SAE J1926/1, BSPP ISO1179
MAGNETIC PICK-UP: Body – 12L14 steel, black oxide finish
Nut – 12L14 steel, zinc plate, dichromate finish
PERFORMANCE:
Electrical Output Signal: Self-generating alternating pulse, 100 mV RMS (100 Hz) min.
The F6202 / F6222 models have a 10 mV RMS (200 Hz) min.
Forward flow accuracy: ±1% of full scale
± 0.5% of rate when used with XLF display.
Repeatability: ± 0.2%
Pressure rating: 5800 psi (400 bar) maximum, 5000 psi (345 bar) maximum for
models F6208-F and F6228-F
Pressure drop: See ∆ P charts.
Turbine response: < 200 ms
Fluid temperature range: -4° to 300° F (-20° to 150° C)
Ambient temperature range: -4° to 131° F (-20° to 55° C)
BI-DIRECTIONAL FLOW: Optional calibration available
Magnetic Pickup
Pressure Port
Adapter
Temperature
Port Adapter
Housing
D
C
B
A
DIMENSIONS:
A
B
C
D
SERIES
WIDTH
in (mm)
LENGTH
in (mm)
HEIGHT
in (mm)
W/MAG
in (mm)
WEIGHT
(lbs)
F6202-F
F6222-F
1.23 (31.2)
4.72 (120.0)
1.47 (37.3)
3.72 (94.5)
1.55
F6204-F
F6224-F
1.48 (37.6)
5.08 (129.0)
1.80 (45.7)
4.05 (102.9)
1.75
F6206-F
F6226-F
1.98 (50.3)
5.87 (149.0) 2.20 ( 56.0)
4.46 (113.3)
2.75
F6208-F
F6228-F
2.46 (62.5)
6.81 (173.0)
4.75 (120.7)
4.10
2.48 (63.0)
5 TEL.1-800-433-5263 V I S I T O U R W E B S I T E – F L O - T E C H . C O M
Ultima Sensor Array
Series
F6200F
/
F6220F
Simultaneously Measures Flow, Pressure and Temperature
ORDERING INFORMATION:
NOMINAL
PORT SIZE
SAE 8 **
SAE 12
SAE 16
SAE 20
G 1/4 **
G 3/4
G1
G 1-1/4
PRESSURE DROP PSI (BAR)
50% MAX FLOW 100% MAX FLOW
10.0 (0.69)
26.0 (1.79)
9.0 (0.62)
25.0 (1.72)
9.0 (0.62)
30.0 (2.07)
8.0 (0.55)
30.0 (2.07)
10.0 (0.69)
26.0 (1.79)
9.0 (0.62)
25.0 (1.72)
9.0 (0.62)
30.0 (2.07)
8.0 (0.55)
30.0 (2.07)
FLOW RATE
0.4 - 7 GPM
2 - 40 GPM
4 - 80 GPM
8 - 160 GPM
1.5 - 26 LPM
7.5 - 151 LPM
15 - 302 LPM
30 - 605 LPM
MODEL
SEALS
F6202 – F
F6204 – F
F6206 – F
F6208 – F
F6222 – F
F6224 – F
F6226 – F
F6228 – F
B*
N*
S*
*Basic
Model
*Basic Model
**Requires SWI-5, Square Wave Interface (F5130, page 25) to amplify
signal to be compatible with XLF digital display. Connecting cable
part numbers are F2836-6, 6-ft. or F2836-15, 15-ft. on page 27.
Seals
B Buna N
When using Ultima Sensor Array with Flo-tech’s XLF Digital Displays use
V Viton
F6234-6, 6-ft. or F6234-15, 15-ft. connecting cables on page 27.
E EPR
Five or Ten Point Calibration Certificates are available.
T
N
S
G
D
Flo-tech P.N.
Description
F001109
Five Point Calibration Certificate
F001110
Ten Point Calibration Certificate
These Certificates are traceable to NIST, ISO 9001/ANSI Z540-1
& MIL-STD 45662A
Ordering Example:
F6204 - F B-T6, SAE 16, 2-40 gpm with Buna N seals,
temperature sensor and 6000 psi pressure sensor
SENSOR PORTS
TEMPERATURE
PRESSURE
Temperature
with Sensor
1/4 NPTF (F) Plugged
SAE #2 (J514) Plugged
G 1/4 (F) Plugged
SAE #4
1
3
5
6
N
S
F
Pressure
1000 psi (69 bar) Sensor
3000 psi (207 bar) Sensor
5000 psi (345 bar) Sensor
6000 psi (414 bar) Sensor
1/4 NPTF (F) Plugged
SAE #2 (J514) Plugged
G 1/4 (F) Plugged
( Example ) F6204 – F B - T 6
THE ULTIMA SENSOR ARRAY PRESSURE DROP CHART
6
100
F6202
F6204
F6206 F6208
F6222
F6224
F6226 F6228
PRESSURE DROP BAR
PRESSURE DROP PSI
1.0
10
1
.1
.01
.006
.1
.1
1
10
100
300
FLOW GPM
XLF DIGITAL DISPLAYS
PAGE 13
.3
10
100
1000
FLOW LPM
PRESSURE SENSORS
TEMPERATURE SENSORS
CABLES
PAGE 23
PAGE 26
PAGE 27
FIVE OR TEN POINT CALIBRATION AVAILABLE FAX: 1- 800- 245-3569 6
Turbine Flow Sensors
Series FSC / FSB / FSD
Bulletin #200
• Variety of Body Materials &
SPECIFICATIONS:
MATERIAL:
Housing: FSC, FSB – 6013-T651 Anodized aluminum; FSD – Stressproof® steel,
zinc plated
Turbine Rotor: T416 Stainless Steel
Rotor Supports: FSC-375, 500, 750 – Brass C360; FSC-1000, 1005; FSB – 6061-T6,
Aluminum alloy; FSD, T303 Stainless steel
Rotor Shaft: FSC, FSB – T303 Stainless steel; FSD, Tungsten carbide
Ball Bearings: FSC, FSB – 440 C Stainless steel: FSD, Tungsten carbide
Hub Cones: FSC, FSB – 6061-T6 Aluminum alloy
Retainer Rings: FSC-375 – T303 Stainless steel: FSC-500, 750, 1000, 1005;
FSB, FSD – zinc plated steel
Seals: Buna-N, standard; Viton and EPR, optional
PORTS: SAE J1926/1, Code 61 and Code 62: SAE J518
MAGNETIC PICKUP:
For the FSC, FSB, FSD:
Body – 12L14 steel, black oxide finish
Nut – 12L14 steel, zinc plate, dichromate finish
Fluid Connections
• Turbine Flow Measurement
• Flow Ranges from 0.4 to 350 GPM
• Pressures up to 6000 PSI
• Temperatures up to 300° F
• Petroleum-based fluids
Classic Turbine Flow Sensors measure the flow
rate of hydraulic fluids and other compatible
liquids. As fluid flows through the sensor it turns
the turbine rotor and as each turbine blade
passes the magnetic pickup an electrical
signal is generated. This frequency signal is
proportional to flow rate and can be transmitted
to Flo-tech’s XLF digital displays to show gpm,
lpm, rpm and other common units of measure.
FSB
FSC
FSD
D
D
D
A
A
A
Magnetic Pickup
Magnetic Pickup
Magnetic Pickup
Housing
Housing
Housing
C
C
C
B
B
B
SERIES
FSC-375*
FSC-500
FSC-750
FSC-1000
FSC-1005
FSB-1250
FSB-1500
FSD-1250
FSD-1500
FSD-2000
MODEL
NUMBER
F2945-ASCM
F2082-ASCM
F2083-ASCM
F2084-ASCM
F2084-ASCM8
F2085-ASBM
F2086-ASBM
F2085-SCDM
F2086-SCDM
F2998-SCDM
A (WIDTH)
1.25 (32)
2.00 (51)
2.00 (51)
2.50 (64)
2.50 (64)
4.00 (102)
4.00 (102)
2.12 (54)
2.50 (64)
3.12 (79)
DIMENSIONS (mm)
B (LENGTH)
C (HEIGHT)
5.00 (127)
1.50 (38)
6.50 (165)
2.00 (51)
6.50 (165)
2.00 (51)
6.50 (165)
2.00 (51)
6.50 (165)
2.00 (51)
7.00 (178)
3.00 (76)
7.00 (178)
3.00 (76)
7.50 (190)
7.50 (190)
8.25 (209)
D (W/MAG)
3.91 (99)
4.16 (106)
4.25 (108)
4.34 (110)
4.34 (110)
4.94 (126)
5.10 (130)
4.50 (114)
4.85 (123)
5.39 (137)
7 TEL.1-800-433-5263 CALL FOR AUTHORIZED DISTRIBUTOR IN YOUR AREA
WEIGHT
(LB)
1.25
2.75
2.87
3.25
3.25
7.75
7.40
6.12
6.75
8.55
Turbine Flow Sensors
Series FSC / FSB / FSD
SPECIFICATIONS (cont.):
PERFORMANCE:
Electrical Output Signal: Self-generating alternating pulse. The
FSC-500, 750, 1000, 1005; FSB; FSD, generate a 100 mV
RMS (100 Hz) minimum. The FSC-375, generate a 10 mV
RMS (200 Hz) minimum.
Forward Flow Accuracy: +/- 1% of full flow rate
Repeatability: +/- 0.2%
Pressure Rating: FSC, FSB – 5000 PSI (345 Bar) maximum;
FSD – 6000 PSI (414 Bar) maximum
Pressure Drop: See ∆ P chart
Turbine Response: < 200 MS
Fluid Temperature Range: -4° to 300° F (-20° to 150° C)
BI-DIRECTIONAL FLOW: Optional calibration available
ORDERING INFORMATION
SERIES
MODEL
NUMBER
NOMINAL
PORT SIZE
FLOW (LPM)
RATE
FSC-375*
FSC-500
FSC-750
FSC-1000
FSC-1005
FSB-1250
FSB-1500
FSD-1250
FSD-1500
FSD-2000
F2945-ASCM
F2082-ASCM
F2083-ASCM
F2084-ASCM
F2084-ASCM8
F2085-ASBM
F2086-ASBM
F2085-SCDM
F2086-SCDM
F2998-SCDM
SAE 8, 1/2" O-Ring Boss
SAE 12, 3/4" O-Ring Boss
SAE 12, 3/4" O-Ring Boss
SAE 16, 1" O-Ring Boss
SAE 16, 1" O-Ring Boss
SAE 20, 1-1/4" Code 61, 4-Bolt Face
SAE 24, 1-1/2" Code 61, 4-Bolt Face
SAE 20, 1-1/4" Code 62, Flange Head
SAE 24, 1-1/2" Code 62, Flange Head
SAE 32, 2" Code 62, Flange Head
0.4 - 7 (1.5-26)
1-15 (4-56)
2-25 (7.5-94)
3-60 (11.5-227)
4-85 (15-321)
5-100 (20-378)
7-200 (27-757)
5-100 (20-378)
7-200 (27-757)
10-350 (37-1324)
PRESSURE DROP PSI (BAR)
50%
100%
MAX FLOW
MAX FLOW
9.0 (.62)
27 (1.86)
7.0 (.48)
20 (1.38)
2.4 (.17)
8 (.55)
5.6 (.38)
21 (1.45)
11.0 (.76)
38 (2.62)
1.6 (.11)
15 (1.03)
5.5 (.38)
25 (1.72)
1.6 (.11)
15 (1.03)
5.5 (.38)
25 (1.72)
4.5 (.31)
20 (1.38)
*Requires SWI-5, square wave interface (F5130, page 25) to amplify signal to be compatible with Flo-tech’s XLF Digital Display.
When using Classic Turbine Flow Sensors with Flo-tech’s XLF Digital Displays, use F2832-6, 6-ft. or F2832-15, 15ft. connecting cables, page 27.
Five or Ten Point Calibration Certificates are available.
Flo-tech P.N.
Description
F001109
Five Point Calibration Certificate
F001110
Ten Point Calibration Certificate
These Certificates are traceable to NIST, ISO 9001/ANSI Z540-1 & MIL-STD 45662A
50
FSC-1000
FSC-1005
PRESSURE DROP PSI
FSC-500
FSD-1250
10
FSC-750
FSC-1000
FSC-1005
FSB-1500
FSD-1500
FSD-2000
FSB-1250
FSD-1250
FSC-375
PRESSURE DROP BAR
FSC-375
4
FSB-1500
FSD-1500
FSD-2000
FSB-1250
FSC-500
1
FSC-750
0.1
0.07
1
1
10
100
500
FLOW GPM
XLF DIGITAL DISPLAYS
PAGE 13
10
100
1000
2000
FLOW LPM
SWI-5 AMPLIFIER
PAGE 25
ACTIVA FLOW SENSORS
PAGE 3
CABLES
PAGE 27
LEARN ABOUT OTHER DIVISIONS’ PRODUCTS FAX: 1- 800- 245-3569 8
Turbine Flow Sensors
Quad Series
Bulletin #200
• Turbine Flow Measurement
• Flow Ranges from 1 to 85 GPM
• Pressures up to 5000 PSI
• Temperatures up to 300° F
• Petroleum-based fluids
Derived from the FSC Series, the F2000 Quad
series of flow meters utilizes two flow
transducers which are 90-degrees electrically out
of phase from each other. As fluid flows through
the sensors it turns the turbine rotor and as each
blade passes the magnetic pickup an electrical
signal is generated.
SPECIFICATIONS:
MATERIAL:
Housing: FSC, 2024-T351 Anodized aluminum
Turbine Rotor: T416 Stainless Steel
Rotor Supports: FSC – Brass C360
Rotor Shaft: FSC – T303 Stainless steel
Ball Bearings: FSC – 440 C Stainless steel
Hub Cones: FSC – 6061-T6 Aluminum alloy
Retainer Rings: FSC – zinc plated steel
Seals: Buna-N, standard; Viton and EPR, optional
PORTS: SAE J1926/1, Code 61 and Code 62: SAE J518
MAGNETIC PICKUP:
Body – 12L14 steel, black oxide finish
Nut – 12L14 steel, zinc plate, dichromate finish
With the addition of a second flow sensor, it is
possible to monitor flow in both directions. The
F2000 Quad is suitable for up-down counters
that can discern the leading and trailing edges of
the two 90-degree signals. Current applications
include using the F2000 as a speed-sensing
device on mobile equipmeent. This bi-directional
flow meter can be used as a governor, sending
frequency signals back to a PLC which enable
it to make the necessary adjustments. Other
functions of this flow meter are in linear
applications where accurate positioning
is required.
Linearization, where the output of the flow
sensor varies by the same percentage as the
flow through the meter, assists the F2000 Quad
series in achieving its +/-1% of full scale
accuracy in both directions. Flow straighteners
are manufactured into each meter to obtain a
laminar flow, also increasing accuracy. Standard
calibration is done using 5-points.
QUAD
Magnetic Pickup (2)
Housing
D
C
A
B
E
SERIES
FSC-2005
FSC-2075
FSC-2100
FSC-2150
MODEL
NUMBER
F2082-ASCQ4
F2083-ASCQ4
F2084-ASCQ4
F2085-ASCQ4
A (WIDTH)
2.00 (51)
2.00 (51)
2.50 (64)
2.50 (64)
B (LENGTH)
6.50 (165)
6.50 (165)
6.50 (165)
6.50 (165)
DIMENSIONS (mm)
C (HEIGHT)
2.00 (51)
2.00 (51)
2.00 (51)
2.00 (51)
D (W/MAG)
4.16 (106)
4.25 (108)
4.34 (110)
4.34 (110)
9 TEL.1-800-433-5263 L E A R N A B O U T O U R C A L I B R AT I O N S E R V I C E S
E
4.05 (102)
4.05 (102)
4.59 (117)
4.59 (117)
Turbine Flow Sensors
Quad Series
SPECIFICATIONS (cont.):
PERFORMANCE:
Electrical Output Signal: Self-generating alternating pulse. The
FSC-2005, 2075, 2100, 2150, generate a 100 mV
RMS (100 Hz) minimum.
Forward Flow Accuracy: +/- 1% of full flow rate
Reverse Flow Accuracy: +/- 1% of full flow rate
Repeatability: +/- 0.2%
Pressure Rating: 5000 PSI (345 Bar) maximum;
Pressure Drop: See ∆ P chart
Turbine Response: < 200 MS
Fluid Temperature Range: -4° to 300° F (-20° to 150° C)
ORDERING INFORMATION
SERIES
MODEL
NUMBER
NOMINAL
PORT SIZE
FLOW (LPM)
RATE
FSC-500
FSC-750
FSC-1000
FSC-1005
F2082-ASCM
F2083-ASCM
F2084-ASCM
F2084-ASCM8
SAE 12, 3/4" O-Ring Boss
SAE 12, 3/4" O-Ring Boss
SAE 16, 1" O-Ring Boss
SAE 16, 1" O-Ring Boss
1-15 (4-60)
2-25 (7.5-94)
3-60 (11.5-227)
4-85 (15-321)
PRESSURE DROP PSI (BAR)
50%
100%
MAX FLOW
MAX FLOW
7.0 (.48)
20 (1.38)
2.4 (.17)
8 (.55)
5.6 (.38)
21 (1.45)
11.0 (.76)
38 (2.62)
When using Quad Turbine Flow Sensors with Flo-tech’s XLF Digital Displays, use F2832-6, 6-ft. or F2832-15, 15ft. connecting cables, page 27.
Five or Ten Point Calibration Certificates are available.
Flo-tech P.N.
Description
F001109
Five Point Calibration Certificate
F001110
Ten Point Calibration Certificate
These Certificates are traceable to NIST, ISO 9001/ANSI Z540-1 & MIL-STD 45662A
FSC-2100
FSC-2150
50
4
FSC-2100
FSC-2150
PRESSURE DROP BAR
PRESSURE DROP PSI
FSC-2005
FSC-2075
10
FSC-2005
1
FSC-2075
0.1
0.07
1
1
10
100
500
XLF DIGITAL DISPLAYS
PAGE 13
10
100
1000
2000
FLOW LPM
FLOW GPM
SWI-5 AMPLIFIER
PAGE 25
ACTIVA FLOW SENSORS
PAGE 3
CABLES
PAGE 27
CALL TO DISCUSS YOUR SPECIFIC APPLICATION FAX: 1- 800- 245-3569 10
Digital Display
Digital Display
For Flo-tech Activa Sensor Arrays
For Flo-tech Ultima and Classic Turbine Flow Sensors
Series F6700 (AC) and F6750 (DC) - Accepts standard 4-20 mA or 0-10 VDC analog signal
Applications
• Remote flow meter monitoring
• Totalizing
• Alarm processing
• Process control
Features
• 5-digit rate display
• 5-digit totalizer with
4-digit overcarry
• Dual inputs, 4-20 mA or 0-10 VDC
• Built-in transmitter power supply
• Three plug-in card slots
• Optional setpoint alarm cards
• AC and DC powered versions
• NEMA 4X / IP65 rated
• CE compliant
MAX
MIN
TOT
Inches
( mm )
SP1
DSP
SP2
PAR
F1
SP3
SP4
F2
RST
The F6700/F6750 series digital display with integrated signal processor accepts a 4-20
mA signal from Flo-tech’s Activa Sensor Array as well as any other 4-20 mA or 0-10 VDC
source. These 5-digit displays can be scaled to most engineering units and are easily
programmed using the front panel buttons or available programming software. To meet your
specific requirements, each display accepts up to three optional plug-in cards. One card for each
of the following function types can be installed in each display:
Analog Outputs – A linear DC output signal card will be set up to provide either a 4-20 mA, 0-20
mA or 0-10 VDC signal and can be scaled independent of the input range.
Communications – Optional plug-in cards to facilitate digital communications include: RS232,
RS485, Modbus, Profibus and DeviceNet.
Setpoint Alarms – Select from dual FORM-C relays (5 Amp), quad FORM-A relays (3 Amp) or
either sinking or sourcing quad open collector logic outputs.
The analog output and communication cards will be installed by the factory at time of order, or
they may be installed by the customer at a later date. The setpoint alarm cards are available for
customer installation and setup only.
SPECIFICATIONS:
Display:
Power:
AC
DC
A/D Converter:
A/D Conversion Rate:
Display Update Rate:
Sensor Inputs:
Transmitter Power:
Totalizer Time Base:
Total:
1.95
(49.5)
5-digit, 0.56" sunlight-readable red LED
Linearization Data
Point Pairs:
Selectable from 2 to 16
Operating Temperature: 32 °F to 122 °F (0 °C to 50 °C)
( 32 °F to 113 °F with all three plug-in cards installed)
Power
0.10
(2.5)
AC
DC
1.75
(44.5)
Display
F6700
F6750
Analog Output
Communications
RS232 – A
RS485 – B
GPM
LPM
– G
– L
0-10 VDC – C
Modbus – C
RPM
– R
None – X
Profibus – D
psi
– P
None – X
4.1
(104.1)
Note: Select one option from each category
Ordering Examples:
F6700-X-X-G = AC powered, displays GPM
F6700-A-A-L = AC powered + 4-20 mA Out + RS232, displays LPM
F6750-C-X-B = DC powered + 0-10 VDC Out, displays bars
2
TEL. 1-800-433-5263
Display Units
4-20 mA – A
0-20 mA – B
DeviceNet – E
The F6600/F6650 series rate/counter digital display with integrated signal processor
accepts the frequency signal from Flo-tech’s Ultima and Classic Turbine Flow Sensors as
well as inputs from a variety of sources including switch contacts, outputs from CMOS or TTL
circuits and magnetic pickups. These meters provide six different display indications, including:
Counter A, Counter B, Counter C (slave display), Rate, Rate Maximum and Rate Minimum.
Annunciators indicate which display is being shown.
Similar to the F6700/F6750 series, these units can be customized to meet individual specificaitons
through the addition of three types of optional plug-in cards: analog outputs, communications
and setpoint alarms. The analog output and communication cards can be installed by the factory
at the time of order, or they may be installed by the customer at a later date. The setpoint alarm
cards are available for customer installation and setup only.
SPECIFICATIONS:
Display:
Rate
Counter
6-digit, 0.56" sunlight-readable red LED
5-digit max, ±0.01% accuracy
8-digit max, >6 digits alternates between high order
and low order
Power:
AC
DC
Sensor Power:
Inputs:
Frequency Range
Trigger Sensitivity
Over Voltage Protected
Operating Temperature:
85 to 250 VAC, 50/60 Hz, 15 VA
11 to 36 VDC, 11 W
16-bit resolution
20 readings/sec
1 to 20 updates/sec
4 to 20 mA or 0 to 10 VDC
24 VDC, ±5%, regulated 50 mA max
Second, minute, hour or day
9 digits, display alternates between
high order and low order readouts
Ordering Information:
3.80
( 96.5 )
Series F6600 (AC) and F6650 (DC) - Accepts standard frequency signal
bars
– B
2
kg/cm
– K
MPa
– M
°F
– F
°C
– C
Form C Relay Plug-in Option Card - Part Number F6542
This optional plug-in card requires customer installation and setup. To facilitate setup,
it is recommended that this feature be utilized with a display that includes a serial
communication card (RS232 or RS485) and programming software.
Display
Analog Output
by Hedland
Communications
Display Units
Inches
( mm )
A
B
C
SP1
DSP
AC
DC
F6600
F6650
4-20 mA – A
0-20 mA – B
RS232 – A
RS485 – B
GPM
LPM
– G
– L
– C
Modbus – C
RPM
– R
None – X
Profibus – D
0-10 VDC
Note: Select one option from each category
SP2
PAR
F1
SP3
SP4
F2
RST
1.95
(49.5)
3.80
( 96.5 )
0.10
(2.5)
DeviceNet – E
None – X
1.75
(44.5)
A K-Factor Scaler, F5140, must be used between turbine sensor models FSC-375,
F6202-F, F6222-F and the F6600/F6650 series displays.
Form C Relay Plug-in Option Card - Part Number F6542
This optional plug-in card requires customer installation and setup. To facilitate
setup, it is recommended that this feature be utilized with a display that includes a serial
communication card (RS232 or RS485) and programming software.
Note: For additional setpoint alarm options, consult factory for information.
4.1
(104.1)
Ordering Examples:
F6600-X-X-G = AC powered, displays GPM
F6600-A-A-L = AC powered + 4-20 mA Out + RS232, displays LPM
F6650-C-X-G = DC powered + 0-10 VDC Out, displays GPM
Note: For additional setpoint alarm options, consult factory for information.
www.flo-tech.com
Features
• 6-digit display
• Count, rate and slave display
• Built-in sensor power supply
• Three plug-in card slots
• Optional setpoint alarm cards
• AC and DC powered versions
• NEMA 4X / IP65 rated
• CE compliant
85 to 250 VAC, 50/60 Hz, 18 VA
11 to 36 VDC, 14 W
12 VDC, ±10%, 100 mA max, short circuit protected
Magnetic pickup
0.01 to 34 K Hz
80 mV p-p
±40 V peak
32 °F to 122 °F (0 °C to 50 °C)
( 32 °F to 113 °F with all three plug-in cards installed)
Ordering Information:
Power
Applications
• Remote flow meter monitoring
• Rate comparisons
• Alarm processing
• Process control
by Hedland
www.flo-tech.com
FAX 1-800-245-3569
3
Digital Display
Digital Display
For Flo-tech Activa Sensor Arrays
For Flo-tech Ultima and Classic Turbine Flow Sensors
Series F6700 (AC) and F6750 (DC) - Accepts standard 4-20 mA or 0-10 VDC analog signal
Applications
• Remote flow meter monitoring
• Totalizing
• Alarm processing
• Process control
Features
• 5-digit rate display
• 5-digit totalizer with
4-digit overcarry
• Dual inputs, 4-20 mA or 0-10 VDC
• Built-in transmitter power supply
• Three plug-in card slots
• Optional setpoint alarm cards
• AC and DC powered versions
• NEMA 4X / IP65 rated
• CE compliant
MAX
MIN
TOT
Inches
( mm )
SP1
DSP
SP2
PAR
F1
SP3
SP4
F2
RST
The F6700/F6750 series digital display with integrated signal processor accepts a 4-20
mA signal from Flo-tech’s Activa Sensor Array as well as any other 4-20 mA or 0-10 VDC
source. These 5-digit displays can be scaled to most engineering units and are easily
programmed using the front panel buttons or available programming software. To meet your
specific requirements, each display accepts up to three optional plug-in cards. One card for each
of the following function types can be installed in each display:
Analog Outputs – A linear DC output signal card will be set up to provide either a 4-20 mA, 0-20
mA or 0-10 VDC signal and can be scaled independent of the input range.
Communications – Optional plug-in cards to facilitate digital communications include: RS232,
RS485, Modbus, Profibus and DeviceNet.
Setpoint Alarms – Select from dual FORM-C relays (5 Amp), quad FORM-A relays (3 Amp) or
either sinking or sourcing quad open collector logic outputs.
The analog output and communication cards will be installed by the factory at time of order, or
they may be installed by the customer at a later date. The setpoint alarm cards are available for
customer installation and setup only.
SPECIFICATIONS:
Display:
Power:
AC
DC
A/D Converter:
A/D Conversion Rate:
Display Update Rate:
Sensor Inputs:
Transmitter Power:
Totalizer Time Base:
Total:
1.95
(49.5)
5-digit, 0.56" sunlight-readable red LED
Linearization Data
Point Pairs:
Selectable from 2 to 16
Operating Temperature: 32 °F to 122 °F (0 °C to 50 °C)
( 32 °F to 113 °F with all three plug-in cards installed)
Power
0.10
(2.5)
AC
DC
1.75
(44.5)
Display
F6700
F6750
Analog Output
Communications
RS232 – A
RS485 – B
GPM
LPM
– G
– L
0-10 VDC – C
Modbus – C
RPM
– R
None – X
Profibus – D
psi
– P
None – X
4.1
(104.1)
Note: Select one option from each category
Ordering Examples:
F6700-X-X-G = AC powered, displays GPM
F6700-A-A-L = AC powered + 4-20 mA Out + RS232, displays LPM
F6750-C-X-B = DC powered + 0-10 VDC Out, displays bars
2
TEL. 1-800-433-5263
Display Units
4-20 mA – A
0-20 mA – B
DeviceNet – E
The F6600/F6650 series rate/counter digital display with integrated signal processor
accepts the frequency signal from Flo-tech’s Ultima and Classic Turbine Flow Sensors as
well as inputs from a variety of sources including switch contacts, outputs from CMOS or TTL
circuits and magnetic pickups. These meters provide six different display indications, including:
Counter A, Counter B, Counter C (slave display), Rate, Rate Maximum and Rate Minimum.
Annunciators indicate which display is being shown.
Similar to the F6700/F6750 series, these units can be customized to meet individual specificaitons
through the addition of three types of optional plug-in cards: analog outputs, communications
and setpoint alarms. The analog output and communication cards can be installed by the factory
at the time of order, or they may be installed by the customer at a later date. The setpoint alarm
cards are available for customer installation and setup only.
SPECIFICATIONS:
Display:
Rate
Counter
6-digit, 0.56" sunlight-readable red LED
5-digit max, ±0.01% accuracy
8-digit max, >6 digits alternates between high order
and low order
Power:
AC
DC
Sensor Power:
Inputs:
Frequency Range
Trigger Sensitivity
Over Voltage Protected
Operating Temperature:
85 to 250 VAC, 50/60 Hz, 15 VA
11 to 36 VDC, 11 W
16-bit resolution
20 readings/sec
1 to 20 updates/sec
4 to 20 mA or 0 to 10 VDC
24 VDC, ±5%, regulated 50 mA max
Second, minute, hour or day
9 digits, display alternates between
high order and low order readouts
Ordering Information:
3.80
( 96.5 )
Series F6600 (AC) and F6650 (DC) - Accepts standard frequency signal
bars
– B
2
kg/cm
– K
MPa
– M
°F
– F
°C
– C
Form C Relay Plug-in Option Card - Part Number F6542
This optional plug-in card requires customer installation and setup. To facilitate setup,
it is recommended that this feature be utilized with a display that includes a serial
communication card (RS232 or RS485) and programming software.
Display
Analog Output
by Hedland
Communications
Display Units
Inches
( mm )
A
B
C
SP1
DSP
AC
DC
F6600
F6650
4-20 mA – A
0-20 mA – B
RS232 – A
RS485 – B
GPM
LPM
– G
– L
– C
Modbus – C
RPM
– R
None – X
Profibus – D
0-10 VDC
Note: Select one option from each category
SP2
PAR
F1
SP3
SP4
F2
RST
1.95
(49.5)
3.80
( 96.5 )
0.10
(2.5)
DeviceNet – E
None – X
1.75
(44.5)
A K-Factor Scaler, F5140, must be used between turbine sensor models FSC-375,
F6202-F, F6222-F and the F6600/F6650 series displays.
Form C Relay Plug-in Option Card - Part Number F6542
This optional plug-in card requires customer installation and setup. To facilitate
setup, it is recommended that this feature be utilized with a display that includes a serial
communication card (RS232 or RS485) and programming software.
Note: For additional setpoint alarm options, consult factory for information.
4.1
(104.1)
Ordering Examples:
F6600-X-X-G = AC powered, displays GPM
F6600-A-A-L = AC powered + 4-20 mA Out + RS232, displays LPM
F6650-C-X-G = DC powered + 0-10 VDC Out, displays GPM
Note: For additional setpoint alarm options, consult factory for information.
www.flo-tech.com
Features
• 6-digit display
• Count, rate and slave display
• Built-in sensor power supply
• Three plug-in card slots
• Optional setpoint alarm cards
• AC and DC powered versions
• NEMA 4X / IP65 rated
• CE compliant
85 to 250 VAC, 50/60 Hz, 18 VA
11 to 36 VDC, 14 W
12 VDC, ±10%, 100 mA max, short circuit protected
Magnetic pickup
0.01 to 34 K Hz
80 mV p-p
±40 V peak
32 °F to 122 °F (0 °C to 50 °C)
( 32 °F to 113 °F with all three plug-in cards installed)
Ordering Information:
Power
Applications
• Remote flow meter monitoring
• Rate comparisons
• Alarm processing
• Process control
by Hedland
www.flo-tech.com
FAX 1-800-245-3569
3
Portable Hydraulic Testers
PFM6
Flo-check® Digital
Hydraulic Test Unit
• Accuracy of ±1%, full range
• Turbine flow sensor gives fast
response
• Large 3-1/2 digit LCD for both
flow and temperature
• Simple operation: one toggle
switch controls power, flow
and temperature; load valve
offers fingertip control of
pressure to 6000 PSI
(41.4 MPa)
• Platinum resistance
thermometer, swept wet well;
fast and accurate
Compact, lightweight, self-contained portable
tester with laboratory accuracy. Designed for
fast diagnostic troubleshooting of all types of
mobile or stationary hydraulic systems and
components. Makes all flow, pressure and
temperature measurements simultaneously
from one point.
Helical type pressure gauge provides
pulsation dampening and high over-pressure
capacity. Pressure relief disc protection.
Low battery/over-range indicators. Metric
units available.
PFM6BD
Flo-check®
Bi-Directional
Hydraulic Test Unit
PFM8
Flo-check® Digital
Hydraulic Test Unit
& Dynamometer
• Provides in-line testing of
• Front panel selectable U.S.
bi-directional motors, servo
systems and valves
• Has the lowest pressure drop
of any bi-directional tester
• Same basic features and ease
of operation as PFM6 model
Compact, lightweight, self-contained portable
tester with laboratory accuracy in either
direction. Designed for fast bi-directional
diagnostic troubleshooting of all types of
mobile or stationary hydraulic systems and
components. Makes all flow, pressure and
temperature measurements simultaneously
from one point. Helical type pressure gauge
provides pulsation dampening and high overpressure capacity. Pressure relief disc
protection. Low battery/over-range indicators.
Metric units available.
or metric readings
• Digital pressure to 6000 PSI
(41.4 MPa)
• Portable dynamometer reads
power (HP & kW) directly
• Large easy-to-use
membrane switch selects
flow, temperature, pressure
or power
• Low noise input circuitry
provides steadier readings
when flow is pulsating or
cavitating
• Auto/OFF automatically
turns power off after 5
minutes with no flow signal
All-digital, compact, lightweight, selfcontained portable hydraulic tester and
dynamometer. Designed for fast diagnostic
troubleshooting of all types of hydraulic
systems and components, including
engine-pump combinations. Makes
all flow, pressure, temperature and power
measurements simultaneously from
one point, in either U.S. or metric units
(switchable). Silicon strain gauge pressure
sensor. Offers other standard features of
PFM6 model.
15 TEL.1-800-433-5263 CALL FOR AUTHORIZED DISTRIBUTOR IN YOUR AREA
Portable Hydraulic Testers
SPECIFICATIONS:
MATERIAL:
Housing: 2024-T351 Anodized aluminum
Turbine Rotor: T416 Stainless steel
Rotor Supports: 6061-T6 Aluminum;
Rotor Shaft: T303 Stainless steel
Seals: Buna N standard; Viton and EPR optional
Ball Bearings: 440 C Stainless steel
Hub Cones: 6061-T6 Aluminum alloy
Temperature Probe: 12L14 Steel (Zinc plate, dichromate finish)
PFM6/8 SERIES TESTERS
Valve Body for 15/30’s: cold rolled steel; 60/85/200 Body:12L14
Steel Stem – 303 Stainless steel
Poppet: 12L14 Steel, Hardened
Straightening section: for 15/30 is CA360 Brass;
for 60/85/200 is 6061-T6 Aluminum
Cones: 2024-T4 Aluminum
200 GPM: Sleeve – D.O.M. steel tube
PFM6BD SERIES TESTERS
Valve: Body - 12L14 Steel
Spool/Sleeve: 4340 Alloy Steel, Hardened
By-Pass Plate: 2024-T351 Aluminum
Straightening section: 6061-T6 Aluminum
Cones: 2024-T4 Aluminum
PORTS: SAE Straight Thread O-Ring Boss, Female, J1926/1;
BSPP ISO1179
MAGNETIC PICK-UP: Body – 12L14 steel, black oxide finish;
Nut – 12L14 steel, zinc plate, dichromate finish
PERFORMANCE:
Electrical Output Signal: Self-generating alternating pulse,
100 mV RMS (100 Hz) min.
Flow accuracy: ±1% of full scale
Repeatability: ± 0.2%
Pressure rating: 6000 psi (414 bar) maximum
Turbine response: ≤ 200 ms
Fluid temperature range: -4° to 300° F (-20° to 150° C)
Ambient temperature range: -4° to 131° F (-20° to 55° C)
Flow readout: linearity and zero shift = +/- 1 digit
Operating pressure: to 6000 PSI (414 Bar, 41.4 MPa, 420 kg/cm2)
Fluid temperature: to 300 F (150 C)
Readout accuracy: +/- 1 digit
Battery type: AA size alkaline; Life 50 hours
-CE Certified models are available in PFM6 & PFM6BD
series units.
-XXX-when ordering, please specify P-PSI, B-Bar, M-MPa,
K-kg/cm2.
Ordering example: FPFM6-200-B-C ordering PFM6-200 w/
SAE24 ports, pressure scaled in bar, and CE certified unit
Five or Ten Point Calibration Certificates are available and
traceable to NIST, ISO 9001 / ANSI Z540-1 & MIL-STD 45662A
DIMENSIONS
SERIES
INCHES
PFM6-15
PFM6-30
PFM6-60
PFM6-85
PFM6-200
PFM6BD-60
PFM6BD-85
PFM6BD-200
PFM8-15
PFM8-30
PFM8-60
PFM8-85
PFM8-200
DIMENSIONS (L x D x H)
LBS (KG)
11.3 X 11.0 X 3.5
11.3 X 11.0 X 3.5
11.5 X 11.0 X 3.5
11.5 X 11.0 X 3.5
12.3 X 11.8 X 4.0
11.3 X 11.0 X 4.0
11.3 X 11.0 X 4.0
11.8 X 11.5 X 4.5
11.3 X 11.0 X 3.5
11.3 X 11.0 X 3.5
11.5 X 11.0 X 3.5
11.5 X 11.0 X 3.5
12.3 X 11.8 X 4.0
WEIGHT
LBS (KG)
287 X 279 X 89
287 X 279 X 89
292 X 279 X 89
292 X 279 X 89
311 X 298 X 101
287 X 279 X 101
287 X 279 X 101
300 X 292 X 114
287 X 279 X 89
287 X 279 X 89
292 X 279 X 89
292 X 279 X 89
311 X 298 X 101
13.85 (6.3)
13.85 (6.3)
16.50 (7.5)
16.50 (7.5)
20.00 (9.1)
16.50 (7.5)
16.50 (7.5)
19.50 (9.0)
13.85 (6.3)
13.85 (6.3)
16.50 (7.5)
16.50 (7.5)
20.00 (9.1)
ORDERING INFORMATION
SERIES
MODEL
NUMBER
PFM6-15
F5080 (CE)-XXX
PFM6-30
F5079 (CE)-XXX
PFM6-60
F5078 (CE)-XXX
PFM6-85
F5077 (CE)-XXX
PFM6-200
F5076 (CE)-XXX
PFM6-15
F5110 (CE)-XXX
PFM6-30
F5111 (CE)-XXX
PFM6-60
F5112 (CE)-XXX
PFM6-85
F5113 (CE)-XXX
PFM6-200
F5114 (CE)-XXX
PFM6BD-60 F5082 (CE)-XXX
PFM6BD-85 F5083 (CE)-XXX
PFM6BD-200 F5084 (CE)-XXX
PFM8-15
F5061
PFM8-30
F5058
PFM8-60
F5052
PFM8-85
F5053
PFM8-200
F5054
NOMINAL
PORT SIZE
SAE 12
SAE 12
SAE 16
SAE 16
SAE 24
G 3/4
G 3/4
G1
G1
G 1-1/2
SAE 16
SAE 16
SAE 24
SAE 12
SAE 12
SAE 16
SAE 16
SAE 24
FLOW
RATE
1-15 GPM
2-30 GPM
3-60 GPM
4-85 GPM
7-199.9 GPM
4-56 LPM
7.5-113.6 LPM
12-227 LPM
15-321 LPM
26-757 LPM
3-60 GPM / 12-227 LPM
4-85 GPM / 15-321 LPM
7-199.9 GPM / 26-757 LPM
1-15 GPM / 4-56 LPM
2-30 GPM / 7.5-113.6 LPM
3-60 GPM / 12-227 LPM
4-85 GPM / 15-321 LPM
7-199.9 GPM / 26-757 LPM
POWER
HP (kW)
52.5 (39)
105 (78)
210 (157)
298 (222)
700 (522)
ACCESSORIES
MODEL
NUMBER
F4934-1530
F4934-6085
F4934-200
F1614-6000
F1614-7500
F001109
F001110
NOMINAL
PORT SIZE
Carrying
Cases
Safety Disc
Calibration
Certificates
FLOW
RATE
15 & 30 GPM / 60 & 113.6 LPM
60 & 85 GPM / 200 & 321 LPM
200 GPM / 757 LPM
0-6000 PSI
0-7500 PSI
Five Point
Ten Point
For pressure drop information, refer to page 22.
LEARN ABOUT OTHER DIVISIONS’ PRODUCTS FAX: 1- 800- 245-3569 16
Sensor Array with Load Valve
Series
F6100
Simultaneously Measures Flow, Pressure and Temperature
• Four flow ranges
• Turbine Flow Measurement
• Pressures up to 6000 psi
(414 bar)
• Temperatures up to 300° F
(150° C)
• Includes Loading Valve
The Sensor Array is used for diagnostic evaluation of hydraulic motors, pumps, valves,
hydrostatic drives and cylinders. When performed as part of a routine preventative
maintenance program, catastrophic or untimely repairs are minimized. All that is
required is to make quick and easy fluid line connections between the sensing array
and appropriate locations in the hydraulic circuit. The load valve is used to create a
restriction so that a relief valve setting or internal leakage of a valve or hydraulic
cylinder can be determined. The efficiency of a hydraulic pump or motor can be
similarly established and compared to factory specifications.
F6100 series sensor arrays are turbine flow meters equipped with auxiliary pressure
and temperature sensors and an internal loading valve. The sensor arrays measure
flow, pressure, and temperature simultaneously. Each sensor has a self-contained
conditioning circuit that converts raw sensor input to a 4-20 mA output signal suitable
for use with Flo-tech’s SIM-Check system analyzers and XLI and XLF readouts. They
are also suitable for use with data loggers, strip chart recorders, and control/monitoring
devices such as PCs and PLCs. An optional pulse output for flow measurement is
also available.
SPECIFICATIONS:
MATERIAL:
Housing: 2024-T351 Anodized aluminum
Turbine Rotor: T416 Stainless steel
Rotor Supports: 6061-T6 Aluminum
Rotor Shaft: T303 Stainless steel
Seals: Buna N standard; Viton and EPR optional
Ball Bearings: 440 C Stainless steel
Hub Cones: 6061-T6 Aluminum alloy
Temperature Probe: 12L14 Steel
F6100 SERIES SENSORS
Valve Body for 15/30’s: cold rolled steel; 60/85/200 Body:12L14 Steel Stem –
303 Stainless steel
Poppet: 12L14 Steel, Hardened
Straightening section: for 15/30 (60/113.5 GPM) is CA360 Brass;
for 60/85/200 (199.9/350/750 LPM) is 6061-T6 Aluminum
Cones: 2024-T4 Aluminum
200 GPM: Sleeve – D.O.M. steel tube
PORTS: SAE Straight Thread O-RingBoss, Female, J1926/1;
BSPP ISO1179
MAGNETIC PICK-UP: Body – 12L14 steel, black oxide finish;
Nut – 12L14 steel, zinc plate, dichromate finish
PERFORMANCE:
Electrical Output Signal: Self-generating alternating pulse, 100 mV RMS (100 Hz) min.
Flow accuracy: ±1% of full scale
Repeatability: ±0.2%
Pressure rating: 6000 psi (414 bar) maximum
Turbine response: ≤ 200 MS
Fluid temperature range: -4° to 300° F (-20° to 150° C)
Ambient temperature range: -4° to 131° F (-20° to 55° C)
For pressure drop information, refer to page 22.
17 TEL.1-800-433-5263 L E A R N A B O U T O U R C A L I B R AT I O N S E R V I C E S
Sensor Array with Load Valve
Series
F6100
Simultaneously Measures Flow, Pressure and Temperature
ORDERING INFORMATION:
NOMINAL
PORT SIZE
SAE 12
SAE 12
SAE 16
SAE 24
G 3/4
G 3/4
G1
G 1-1/2
MODEL
NUMBER
F6150
F6153
F6156
F6159
F6161
F6163
F6165
F6167
FLOW RATE
1 - 15 GPM
2 - 30 GPM
4 - 85 GPM
7 - 199.9 GPM
4 - 56 LPM
7.5 - 113.6 LPM
15 - 321 LPM
26 - 757 LPM
Ordering Example:
F6154-AB-T6, SAE #16, 3-60 GPM with
4-20 mA flow transducer, 4-20 mA
temperature transducer & 6000 psi pressure
sensor with 4-20 mA electrical output.
FLOW
TRANSDUCER
SEALS
A
B
Flow
Seals
Transducer
B Buna N
A 4-20 mA Output V Viton
F Frequency Output E EPR
Five or Ten Point Calibration Certificates are
available.
Flo-tech P.N.
Description
F001109
Five Point Calibration Certificate
F001110
Ten Point Calibration Certificate
F6150-AB-T1
F6150-AB-T3
F6150-AB-T6
F6153-AB-T1
F6153-AB-T3
F6153-AB-T6
F6156-AB-T1
F6156-AB-T3
F6156-AB-T6
F6159-AB-T1
F6159-AB-T3
F6159-AB-T6
F6161-AB-T1
F6161-AB-T3
F6161-AB-T3
F6163-AB-T1
F6163-AB-T3
F6163-AB-T6
F6165-AB-T1
F6165-AB-T3
F6165-AB-T6
F6167-AB-T1
F6167-AB-T3
F6167-AB-T6
F6162
F6233
F1614-6000
F1614-7500
ITEM
DESCRIPTION
Turbine-type Flow Block with Active Magnetic (Flow)
Transducer, Active Pressure Transducer and
Active Temperature Sensor
Turbine-type Flow Block with Active Magnetic (Flow)
Transducer, Active Pressure Transducer and
Active Temperature Sensor
Turbine-type Flow Block with Active Magnetic (Flow)
Transducer, Active Pressure Transducer and
Active Temperature Sensor
Turbine-type Flow Block with Active Magnetic (Flow)
Transducer, Active Pressure Transducer and
Active Temperature Sensor
Turbine-type Flow Block with Active Magnetic (Flow)
Transducer, Active Pressure Transducer and
Active Temperature Sensor
Turbine-type Flow Block with Active Magnetic (Flow)
Transducer, Active Pressure Transducer and
Active Temperature Sensor
Turbine-type Flow Block with Active Magnetic (Flow)
Transducer, Active Pressure Transducer and
Active Temperature Sensor
Turbine-type Flow Block with Active Magnetic (Flow)
Transducer, Active Pressure Transducer and
Active Temperature Sensor
Cable, Sensor Array (with 3 Female Connectors) 30 ft.
Cable Auxiliary (with single Female Connector) 30 ft.
Safety Disc, 6000 PSI
Safety Disc, 7500 PSI
6
T
Temperature
Transducer Output:
4-20 mA
T with Sensor
G G 1/4 (F) Plugged
O SAE #2 (J514) Plugged
1
3
6
G
O
Pressure Transducer
Output: 4-20 mA
1000 psi (69 bar) Sensor
3000 psi (207 bar) Sensor
6000 psi (414 bar) Sensor
G 1/4 (F) Plugged
1/4 NPTF (J514) Plugged
( Example ) F6154 – A B - T 6
ACTIVA™ AUXILIARY
PRESSURE SENSORS WITH 4-20mA
SIM™ SENSOR ARRAY WITH LOAD VALVE
PART
NUMBER
SENSOR PORTS
TEMPERATURE
PRESSURE
PORTS
FLOW
PRESSURE
SAE 12
SAE 12
SAE 12
SAE 12
SAE 12
SAE 12
SAE 16
SAE 16
SAE 16
SAE 24
SAE 24
SAE 24
G 3/4
G 3/4
G 3/4
G 3/4
G 3/4
G 3/4
G1
G1
G1
G 1-1/2
G 1-1/2
G 1-1/2
1-15 GPM
1-15 GPM
1-15 GPM
2-30 GPM
2-30 GPM
2-30 GPM
4-85 GPM
4-85 GPM
4-85 GPM
7-199.9 GPM
7-199.9 GPM
7-199.9 GPM
4-56 LPM
4-56 LPM
4-56 LPM
7.5-113.6 LPM
7.5-113.6 LPM
7.5-113.6 LPM
15-321 LPM
15-321 LPM
15-321 LPM
26-757 LPM
26-757 LPM
26-757 LPM
0-1K PSI
0-3K PSI
0-6K PSI
0-1K PSI
0-3K PSI
0-6K PSI
0-1K PSI
0-3K PSI
0-6K PSI
0-1K PSI
0-3K PSI
0-6K PSI
0-69 BAR
0-207 BAR
0-414 BAR
0-69 BAR
0-207 BAR
0-414 BAR
0-69 BAR
0-207 BAR
0-414 BAR
0-69 BAR
0-207 BAR
0-414 BAR
PART
NUMBER
F6301-15
F6301-30
F6301-60
F6301-100
F6301-150
F6301-200
F6301-300
F6301-500
PRESSURE
PSI
BAR
0-15
0-30
0-60
0-100
0-150
0-199
0-300
0-500
0-1.035
0-2.07
0-4.14
0-6.9
0-10.35
0-13.80
0-20.70
0-34.5
PORTS
PART
NUMBER
1/4
NPT
Male
F6301-750
F6301-1K
F6301-2K
F6301-3K
F6301-5K
F6301-7.5K
F6301-10K
F6301-15K
PRESSURE
PSI
BAR
0-750
0-1000
0-2000
0-3000
0-5000
0-7500
0-10,000
0-15,000
0-51.75
0-69
0-138
0-207
0-345
0-517.5
0-690
0-1035
PORTS
1/4
NPT
Male
ACTIVA™ AUXILIARY RTD
TEMPERATURE SENSORS WITH 4-20mA
PART
NUMBER
F6310
F6233
ITEM DESCRIPTION
Temperature Sensor, -40° to 350° F, Thread-5/16-24 UNF-2B, suitable for
SAE J1926-2 O-Ring Boss (SAE #2)
Cable, Auxiliary (with Female Connector) 30 ft.
CALL TO DISCUSS YOUR SPECIFIC APPLICATION FAX: 1- 800- 245-3569 18
F6100Pressure
& PFM
Series
Drop Information
FLOW VS PRESSURE DROP
120
100
100
80
80
PSI
PSI
FLOW VS PRESSURE DROP
120
60
60
PFM6-15
F6150
F6161
PFM6-30
F6153
F6163
40
40
20
20
0
0
0
5
10
GPM
15
20
0
10
20
GPM
40
FLOW VS PRESSURE DROP
FLOW VS PRESSURE DROP
120
120
100
100
80
80
PSI
PSI
30
60
60
PFM6-85
F6156
F6165
PFM6-60
40
40
20
20
0
0
0
20
10
30
40
50
60
70
0
10
20
30
40
GPM
50
60
70
80
90
100
GPM
PFM6BD-60 FLOW VS PRESSURE DROP
FLOW VS PRESSURE DROP
120
220
200
100
180
160
80
PSI
PSI
140
60
PFM6-200
F6159
F6167
120
FORWARD
100
REVERSE
80
40
60
40
20
20
0
0
0
20
40
60
80
100
120
GPM
140
160
180
200
220
0
10
20
30
40
50
60
70
GPM
PFM6BD-85 FLOW VS PRESSURE DROP
PFM6BD-200 FLOW VS PRESSURE DROP
120
150
135
100
120
105
80
PSI
PSI
90
FORWARD
60
FORWARD
75
REVERSE
REVERSE
60
40
45
30
20
15
0
0
0
10
20
30
40
50
GPM
60
70
80
90
100
0
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220
GPM
LEARN ABOUT OTHER DIVISIONS’ PRODUCTS FAX: 1- 800- 245-3569 22
F6301
Pressure
Sensor
With 4-20 mA Output
Bulletin #514
• 4-20 mA electrical output
• Long-term stability & repeatability
• Wide range of pressures available
• Stainless steel NEMA 4X
enclosure
The F6301 Pressure Sensors utilize polysilicone
strain resistors to create very low noise levels
with very high signal output. The metal
diaphragm and polysilicone bridge are
unaffected by shock, vibration or mounting
position.
These sensors are ideal for any application
where measuring pressures are required.
SPECIFICATIONS:
OVERPRESSURE: Full scale in PSI
0-15 to
0-3000 to
0-7500 to
0-2000
0-5000
0-15,000
Proof
200%
150%
120%
Burst
800%
300%
150%
ACCURACY: ± 1% of full scale
Non-Linearity: ±0.7%
Hysteresis: ±0.2%
Non-repeatability: ±0.07%
DURABILITY: 10 8 cycles 20/80% full scale with negligible performance change
RESPONSE TIME: < 5ms
ENVIRONMENTAL EFFECTS:
Humidity: No performance effect at 95% relative humidity-noncondensing
Position Effect: < 0.01% full scale
TEMPERATURE:
Storage: -65° to +250° F (-54° to 121° C)
Operating: -20° to +180° F (-29° to 82° C)
Compensating: -20° to +160° F (-29° to 71° C)
PRESSURE RANGES
Part No.
F6301-15
F6301-30
F6301-60
F6301-100
F6301-150
F6301-200
F6301-300
F6301-500
F6301-750
F6301-1K
F6301-2K
F6301-3K
F6301-5K
F6301-6K
F6301-7.5K
F6301-10K
F6301-15K
PSI
0 - 15.00
0 - 30.0
0 - 60.0
0 - 100.0
0 - 150.0
0 - 200
0 - 300
0 - 500
0 - 750
0 - 1000
0 - 2000
0 - 3000
0 - 5000
0 - 6000
0 - 7500
0 - 10,000
0 - 15,000
BAR
0 - 1.034
0 - 1.999
0 - 4.13
0 - 6.89
0 - 10.34
0 - 13.78
0 - 19.99
0 - 34.5
0 - 51.7
0 - 68.9
0 - 137.8
0 - 199.9
0 - 345
0 - 414
0 - 517
0 - 689
0 - 1034
23 TEL.1-800-433-5263 L E A R N A B O U T O U R C A L I B R AT I O N S E R V I C E S
kg/cm2
0 - 1.055
0 - 1.999
0 - 4.22
0 - 7.03
0 - 10.55
0 - 14.06
0 - 19.99
0 - 35.1
0 - 52.7
0 - 70.3
0 - 140.6
0 - 199.9
0 - 351
0 - 422
0 - 527
0 - 703
0 - 1055
Ports
1/4
NPT
Male
F6301 Pressure
Sensor
With 4-20 mA Output
SPECIFICATIONS (cont.):
THERMAL COEFFICIENTS (68° F ref.) % full scale / ° F
Standard:
Zero: ±0.04%
Span: ±0.04%
VIBRATION SWEEP: < ±0.1% full-scale effect for 0-2000 Hz at
20 g’s in any axis
SHOCK: < ±0.5% full-scale effect for 100 g’s, 20 ms shock in any axis
ELECTRICAL:
Output Signal: 4-20 mA (2 wire)
Load Limitations 4-20mA Output Only
(R LOOP)
1182
LOOP SUPPLY VOLTAGE (VDC)
1000
POWER REQUIREMENTS: 10-36 V DC unregulated 4-20 mA,
reverse polarity protected.
CIRCUIT TO CASE INSULATION RESISTANCE:
100 M ohms @ 50 Vdc
PHYSICAL:
Enclosure: NEMA 4X
Weight: 2 oz. (approximate without cable)
MATERIALS:
Case: 300 series stainless steel
Cable: No. 24 AWG, 36" PVC, shielded, vented, UL approved.
Diaphragm: 17-4 PH stainless steel
Connections: 1/4 NPT male
These pressure sensors are compatible with Flo-tech’s XLI Digital
displays (page 11) and F6234-6, 6-ft. or F6234-15, 15-ft.
connecting cables. (page 27).
V min = 10V = (.022A x RL)
RL = RS = RW
RL = LOOP RESISTANCE (ohms)
RS = SENSE RESISTANCE (ohms)
RW = WIRE RESISTANCE (ohmns)
750
500
250
0
0
10
20
30
36
2.70"
(69mm)
CABLE 3 ft. (.91m)
.85"
(22mm)
2
3
1
1 - N/C
2 - SIGNAL OUTPUT
3 - +VDC
5/8" Hex
4.00"
(102mm)
XLI DIGITAL DISPLAYS
ACTIVA FLOW SENSORS
TEMPERATURE SENSORS
CABLES
PAGE 11
3
PAGE 21
26
PAGE 34
27
PAGE 32
CALL TO DISCUSS YOUR SPECIFIC APPLICATION FAX: 1- 800- 245-3569 24
K-Factor Scaler
Frequency Divider
SPECIFICATIONS
External Power:
Input Voltage
Maximum
Current Draw
8.5 to 30 VDC, diode protected
18 mA, using internal resistor @
30 VDC input
Inputs:
Magnetic pick-up
Frequency Range 0-4000 Hz
Trigger Sensitivity 30 mV p-p to 30 V p-p
Output Signal:
30 VDC max voltage (open collector
transistor) 0.25 W max power
Pulse type, using internal pull-up resistor;
VH = power input voltage - 0.7 VDC
VL = less than 0.4 V @ max input power
Pulse type, using external pull-up resistor;
VH = input voltage to external pull-up resistor
VL = [VH /(selected resistor value + 47Ω)] × 47Ω
Pulse length;
150μs, 1ms, 25ms, 100ms, 500ms, 1s or auto
mode selectable
Internal Pull-up
Resistor:
Jumper disable option 3.6K Ohm
Operating
Temperature:
-22 to +158 °F (-30 to +70 °C)
Enclosure:
UL 94-5VA flame retardant ABS with
mounting flanges
DIMENSIONS - Inches (mm)
• Pre-amplifier for low level turbine meter
• Interface for pulse output devices to PLC, RTU, PC
data acquisition card or similar devices
• Scale turbine meter output to desired engineering units
• On board microcontroller
• Internal or external pull-up resistor
• Compact ABS enclosure with mounting flanges
• Field adjustable (with optional software)
• K-factor range 1- 999,999,999
The K-Factor Scaler is a field adjustable frequency divider
that converts the low level frequency output from a turbine
meter into a scaled square wave output signal. This
amplified, square wave output signal will interface with
any frequency or counter input data collection device.
Due to the low level frequency signal of the FSC-375 and
the Ultima F6202-F and F6222-F series turbine meters, the
K-Factor Scaler is required to amplify the signal of these
turbine meters for transmission to the Flo-tech F6600 and
F6650 Series digital displays.
The K-Factor Scaler is also capable of converting the
frequency output of a turbine meter into a different
frequency, representing another unit of measure, such as
liters, barrels, cubic feet, etc. This requires the optional
programming software kit and the K-factor information
unique to the turbine meter.
ORDERING INFORMATION
MODEL
PART NUMBER
K-Factor Scaler
F5140
Programming Software Kit
F5141
DEPENDABLE CUSTOMER SERVICE
Fax 800-245-3569
25
F6310
Temperature Sensors
With 4-20 mA Output
Bulletin #515
• RTD Temperature element
• 4-20 mA electrical output
• Temperatures up to 350° F
• Withstand pressures up to
6000 PSI
These two-wire platinum RTD (resistance
temperature dector) sensors with 4-20 mA
output are designed for direct insertion into high
pressure fluid systems without need for special
pressure fittings. They are ideal for indicating
system operating conditions, temperature testing
and process measurements and control.
SPECIFICATIONS:
TEMPERATURE RANGE:
Ambient: -40° to +350° F (-40° to +177° C)
Fluid: -4° to +350° F (-20° to +177° C)
Dedicated Input and Span Range: -40° to +350° F (-40° to +177° C)
ACCURACY: Chart A
CURRENT SPAN RANGE: 4-20 mA
RESPONSE TIME: 3 seconds
MAXIMUM PRESSURE: 6000 PSI (414 Bar, 422 kg/cm2)
OPERATING LOOP VOLTAGE:
Minimum: 9V + Voltage of load resistor at 20 mA
Maximum: 28V
Minimum Load Resistance: 10 ohms
Maximum Load Resistance: Loop Voltage – 9V
Ohms
(including wiring losses)
20 mA
Compatible with Flo-tech XLI Digital display (page 11) and connecting cable,
F6234-15, 15-ft. cable (page 27)
CHART A
Combined
Celsius
Celsius/Fahrenheit
Only
Temperature
Accuracy Temp. Accuracy
-40° C -40° F ±0.8° C -40° C ±0.8° C
0° C +32° F ±0.6° C
0° C ±0.6° C
+100° C +212° F ±1.2° C +50° C ±0.9° C
+176° C +350° F ±1.7° C +100° C ±1.2° C
–
–
–
+150° C ±1.5° C
–
–
–
+176° C ±1.7° C
–
–
–
–
–
Fahrenheit
Only
Temp. Accuracy
-40° F ±1.4° F
0° F ±1.2° F
+50° F ±1.2° F
+100° F ±1.5° F
+200° F ±2.1° F
+300° F ±2.7° F
+350° F ±3.0° F
.85"
(22mm)
5/16-24 UNF-2B
Suitable for
SAE J1926-2
O-Ring Boss
(SAE #2)
2.81"
(72mm)
3.41"
(87mm)
3
2
1
Pin Configuration
1 Case Ground
2 Signal
3 + Voltage
0.25" (6.4mm)
ACTIVA FLOW SENSORS
PAGE 3
PRESSURE SENSORS
XLI DIGITAL DISPLAYS
CABLES
PAGE 23
PAGE 11
PAGE 27
FIVE OR TEN POINT CALIBRATION AVAILABLE FAX: 1- 800- 245-3569 26
Cables
Flo-tech offers a complete selection of mating cables to
complete your hydraulic measurement system.
To select the appropriate cable for your application, refer
to the Connecting Cable Charts shown below and on the
next page.
Connecting Cable
Connecting Ends
Signal
Amplifier
Digital Display
F2832-6, 6 ft or
F2832-15, 15 ft
MS female to
tinned leads
F5140
K-Factor Scaler
F6600 / F6650 Series
F2832-6, 6 ft or
F2832-15, 15 ft
2-Pin (MS) female to
tinned leads
—
F6600 / F6650 Series
or HB2800 Series
F6234-6, 6 ft or
F6234-15, 15 ft
3-Pin female to
tinned leads
F5140
K-Factor Scaler
F6600 / F6650 Series
or HB2800 Series
F6234-6, 6 ft or
F6234-15, 15 ft
3-Pin female to
tinned leads
—
F6600 / F6650 Series
F6557-6, 6 ft or
F6557-15, 15 ft
5-Pin female to
tinned leads
—
F6700 / F6750 Series
F6557-6, 6 ft or
F6557-15, 15 ft
5-Pin female to
tinned leads
—
F6700 / F6750 Series
F6301-X
(Pressure Sensors)
F6234-6, 6 ft or
F6234-15, 15 ft
3-Pin female to
tinned leads
—
F6700 / F6750 Series
F6310
(Temperature Sensor)
F6234-6, 6 ft or
F6234-15, 15 ft
3-Pin female to
tinned leads
—
F6700 / F6750 Series
Sensor Model
FSC-375
FREQUENCY
FSC-500
FSC-750
FSC-1000
FSC-1005
FSB-1250
FSB-1500
FSD-1250
FSD-1500
FSD-2000
F6202-F / F6222-F
F6204-F / F6224-F
F6206-F / F6226-F
F6208-F / F6228-F
FSC-375 with IFC
FSC-500 with IFC
FSC-750 with IFC
FSC-1000 with IFC
FSC-1005 with IFC
FSB-1250 with IFC
ANALOG
FSB-1500 with IFC
FSD-1250 with IFC
FSD-1500 with IFC
FSD-2000 with IFC
F6202-AI / F6222-AI
F6202-AV / F6222-AV
F6204-AI / F6224-AI
F6204-AV / F6224-AV
F6206-AI / F6226-AI
F6206-AV / F6226-AV
F6208-AI / F6228-AI
F6208-AV / F6228-AV
28
Tel 800-433-5263
MEASURE SYSTEM PERFORMANCE
Common Conversions
To Convert
Barrel (U.S. liquid)
Bars
Bars
Centigrade
Cubic centimeters
Cubic centimeters
Cubic centimeters
Cubic centimeters
Cubic centimeters
Cubic feet
Cubic feet
Cubic feet
Cubic feet
Cubic feet
Cubic feet
Cubic feet/min
Cubic feet/min
Cubic feet/min
Cubic feet/sec
Cubic inches
Cubic inches
Cubic inches
Cubic inches
Cubic inches
Cubic inches
Cubic meters
Cubic meters
Cubic meters
Cubic meters
Cubic meters
Degree Fahrenheit
Feet/min
Into…
Gallons
Kgs/sq meter
Pounds/sq in
Fahrenheit
Cu feet
Cu inches
Cu meters
Gallons (U.S. liquid)
Liters
Cu cms
Cu inches
Cu meters
Gallons (U.S. liquid)
Imperial gallons
Liters
Cu cms/min
Gallons/min
Liters/min
Gallons/min
Cu cms
Cu feet
Cu meters
Gallons (U.S. liquid)
Imperial gallons
Liters
Cu cms
Cu feet
Cu inches
Gallons (U.S. liquid)
Liters
Degree Celsius
Cms/sec
Multiply by…
31.5
10,200
14.50
(C° x 9.5) +32
.00003521
0.06102
.000001
.0002642
0.001
28,320
1,728
0.02832
7.48052
6.23210
28.317
28,317
7.481
28.32
448.83
16.39
.0005787
.00001639
.004329
.0036065
0.01639
1,000,000
35.31
61,023
264.2
1,000
t° C = (t° F – 32)/1.8
0.5080
To Convert
Feet/min
Gallons/min
Gallons/min
Gallons/min
Imperial gallons
Imperial gallons
Imperial gallons
Imperial gallons
Kilograms/sq cm
Kilograms/sq cm
Kilograms/sq meter
Kilograms/sq meter
Liters
Liters
Liters
Liters
Liters
Liters
Liters/min
Liters/min
Liters/min
Pascal (Pa)
Pascal (Pa)
Pounds/sq inch
Pounds/sq inch
Pounds/sq inch
U.S. gallons
U.S. gallons
U.S. gallons
U.S. gallons
U.S. gallons
U.S. gallons
Into…
Meters/min
Cu cms/min
Cu feet/min
Liters/min
Cu feet
Cu inches
Liters
U.S. gallons
Pounds/sq ft
Pounds/sq in
Bars
Pounds/sq in
Cu cm
Cu feet
Cu inches
Cu meters
Gallons (U.S. liquid)
Imperial gallons
Cu cms/min
Cu feet/min
Gallons/min
Bar
Pounds/sq in
Kgs/sq meter
Pascal (Pa)
Bar
Imperial gallons
Cu cms
Cu feet
Cu inches
Cu meters
Liters
Multiply by…
0.3048
3,785.412
.1337
3.785
.160459
277.274
4.54374
1.20032
2,048
14.22
.00009807
.001422
1,000
0.0353145
61.0234
0.001
0.264170
.220083
1000
.035
.264
.00001
.000145
703.1
6,895
.069
.83267
3785
.133681
231
.3785
3.785
Viscosity Conversion Table
Saybolt Universal
Seconds (SSU)
ISO-VG
CentiStoke
CentiPoise*
Typical Brands/Liquids at 100° F
31
2
1.0
0.876
Water
35
3
2.5
2.19
–
40
5
4.2
3.68
–
45
5/7
5.9
5.17
–
50
7
7.5
6.57
Kerosene
55
7/10
8.8
7.71
Atlantic Richfield/Duro 55 Hyd. Oil
60
10
10.5
9.20
Monsanto/Skydrol - 500 A
70
10/15
13.2
11.56
Mobil/Aero HFA Hydraulic Oil
80
15
15.7
13.75
No 4 Fuel Oil
90
22
18.2
15.94
Stauffer Chemical/Fyrquel 90
100
22
20.6
18.05
Conoco/Syncon Synthetic AW Hyd. Oil
150
32
32.0
28.03
Mobile/DTE 24 Hydraulic Oil
200
46
43.2
37.84
Citco/Glycol FR-40XD (Oil in Water)
300
68
65.0
56.94
SAE 20 Crankcase Oil
400
68/100
86.0
75.34
Sunoco/Sunvis 41 Hydraulic Oil
500
100
108
94.61
SAE 30 Crankcase Oil
750
150
162
141.91
SAE 40 Crankcase Oil
1000
220
216
189.22
Mobil/Paper Machine Oil - Type K
1500
320
323
282.95
SAE 50 Crankcase Oil
2000
460
431
377.56
Amoco/American Industrial Oil - No. 460
3000
680
648
567.65
SAE 140 Gear Oil
4000
1000
862
755.11
SAE 250 Gear Oil
* Centipoise are given for oil of 0.876 specific gravity. Relationship: centistokes X specific gravity = centipoise
FAX: 1- 800- 245-3569 28
Notes
29 TEL.1-800-433-5263 CALL FOR AUTHORIZED DISTRIBUTOR IN YOUR AREA
Flo-tech
®
by
DIVISION OF RACINE FEDERATED, INC.
2200 SOUTH STREET – RACINE, WI 53404 – TEL. (262) 639-6770
30
Hedland® Flow Meters
Hedland offers over 7000 in-line, direct reading flow
meters with an accuracy of ±2% of full scale. This
unique spring loaded variable-area design allows
for installation in any position without affecting the
accuracy. The meters can be installed quickly without
costly flow straighteners or other special plumbing
requirements. Available in Aluminum, Brass and
Stainless from 1/4" to 3" NPTF, SAE and BSP port
sizes. These meters are ideal to monitor a wide range
of liquids and gases including aggressive chemicals,
under a wide range of pressures, temperatures
and rigorous conditions encountered in industrial
applications. For more information, refer to the
Hedland Flow Meter catalog, form #140-2G
EZ-View® Flow Meters
Featuring Hedland‘s unique spring loaded variable-area
design. EZ-View meters can be installed in any position
without affecting accuracy. They can be installed quickly
without costly flow straighteners or other special
plumbing requirements. These meters operate within
±7% accuracy and are constructed of Polysulfone
plastic. Available in 1/2, 3/4 & 1" NPTF or 3/4" & 1"
brass and PVC sweat fittings. An optional AC or DC
Flow-Alert flow-switch automatically signals alarms if
flow is too high or too low. For more information,
refer to the EZ-View Flow Meter catalog, form #239.
Flo-tech Hydraulic Diagnostic Products
Flo-tech offers a line of hydraulic diagnostic products
to assist in troubleshooting all types of hydraulic
systems. Portable Hydraulic Testers are designed
to monitor flows to 200 GPM (750 LPM), pressures
to 6,000 psi (413 bar) and temperatures to 300°F
(149°C). These portable battery-operated testers
are available in a variety of flow ranges and port
sizes. For more information, refer to the Flo-tech
New Generation Portable Hydraulic Tester catalog,
form #208 and the SIM Check Portable Hydraulic
System Analyzer catalog, form #507.
If you have any questions or would like to receive
literature on any of the above product lines, please
feel free to contact one of our Customer Service
Representatives by telephone at (262) 639-6770/
(800) 433-5263 or by telefax at (262) 639-2267/
(800) 245-3569 or visit our Web site: www.hedland.com
Flo-tech
by
®
MAILING ADDRESS
P.O. BOX 1405
RACINE, WI 53401
SHIPPING ADDRESS
2200 SOUTH STREET
RACINE, WI 53404
TELEPHONE:
(262) 639-6770
FAX:
(262) 639-2267
DISTRIBUTED BY:
Form No. 300 8/01
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement