l i nda b | we si mpl i f y c onstr u ction LindabPlexus Supply air beam Installation instructions lin dab | w e s i m p l i fy c o n s t r u c t i o n Plexus 1 Content and symbols 1.1 Content 1. Content and symbols....................................... 2 1.1 Content..................................................................... 2 1.2 Symbols................................................................... 3 2. Control of delivery........................................... 3 2.1 Before you start........................................................ 3 2.2 Safe operation.......................................................... 3 2.3 Receipt of goods..................................................... 3 2.4 Unloading of goods................................................. 3 2.5 Handling / Carrying.................................................. 3 2.6 Tools......................................................................... 4 2.7 Installation................................................................ 4 2.8 Where to find additional instructions or technical documentation......................................................... 4 2.9 Cleaning after assembly/before commissioning..... 4 2.10 Packing, unpacking guideline................................ 5 2.11 Product labelling..................................................... 6 2.12 Order code............................................................. 7 2.13 Order code examples............................................. 7 2.14 Label....................................................................... 7 2.15 Contents of order................................................... 8 2.16 Plus features........................................................... 8 2.16.1 Inlet faceplates..................................................... 8 2.16.2 Outlet front grilles...................................................... 8 2.16.3 Integrated valves................................................. 8 2.16.4 Integrated Actuators............................................ 8 2.16.5 Integrated Regula components.......................... 8 2.17 Accessories............................................................ 8 3. Product specification....................................... 9 3.1 Product description................................................. 9 3.2 Dimensions.............................................................. 9 3.3 Plexus....................................................................... 9 3.4 Material data.......................................................... 10 3.5 Environmental Declarations................................... 10 3.6 Working and test pressure.................................... 10 3.7 Water quality.......................................................... 10 3.8 Air quality............................................................... 10 3.9 Capacity test.......................................................... 10 4 Connections.....................................................11 4.1 Water connections................................................. 11 4.1.1 Before installation................................................ 11 4.1.2 Push on fitting..................................................... 12 4.1.3 Compression fitting............................................. 12 4.1.4 Flexible hoses...................................................... 12 4.1.5 Additional Lindab accessories for water connections......................................................... 13 4.1.6 Possible connections water cooling (2-pipe, Standard).................................................. 14 4.1.7 Possible connections water cooling and heating (4-pipe, Plus feature) ................................. 14 4.2. Air connections..................................................... 16 4.2.1 Air connection installation................................... 16 2 4.2.2 Possible connections supply air......................... 16 4.2.3 Possible connections exhaust air....................... 16 4.3 Possible combination of connections................... 16 4.4 Electrical connections........................................... 17 4.4.1 Regula components on the beam....................... 17 4.4.2 Example 1: Wiring scheme with Regula Connect multi...................................................... 18 4.4.3 Example 2: Wiring scheme with Regula Connect basic..................................................... 18 4.4.4 Regula Connect on the beam............................. 19 4.4.5 Regula Secura on the beam............................... 19 4.4.6 Valves and Actuators on the beam..................... 19 4.4.7 Regula Combi on/with the beam........................ 19 4.4.8 Actuators............................................................. 19 5 Installation of product..................................... 20 5.1 Handling of product............................................... 20 5.2 Ceiling systems...................................................... 20 5.3 General installation principles............................... 21 5.3.1 Recessed in suspended T-bar ceiling................ 21 5.3.2 Exposed, sealed to the ceiling........................... 21 5.3.3 Exposed, free hanging........................................ 21 5.3.4 Free hanging above perforated or eggcrate ceiling.................................................................. 21 5.3.5 Recessed in suspended (permanent) ceiling.................................................................. 21 5.3.6 Recessed in suspended (permanent) ceiling without cover flanges.......................................... 21 5.4 Preparation for installation on the product............ 22 5.5 Preparation for installations of the product........... 23 5.5.1 Basics steps of installing the product................ 24 6 Adjustment and commissioning...................... 28 6.1 Airflow and pressure.............................................. 28 6.1.1 Jet cone 2 adjustment pins................................. 28 6.1.2 Finding values for JetCone pins ......................... 29 6.1.3 Adjusting air flow and pressure with JetCone pins....................................................................... 29 6.2 Adjustment of air distribution profile..................... 30 6.3 Measuring air pressure and calculating the air flow......................................................................... 30 6.3.1 Measuring static nozzle pressure and air pressure.............................................................. 30 6.3.2 Calculating the actual air flow............................ 30 6.3.3 Changing the actual air flow............................... 30 6.3.4 Changing the air distribution profile................... 30 6.3.5 Plexus pressure / airflow diagrams.................... 31 6.4 Water flow rate....................................................... 32 6.4.1 Pre-setting of valves........................................... 32 6.4.2 Balancing strategy.............................................. 32 7. Maintenance................................................... 33 7.1 Remove the outlet front grille................................. 33 7.2 Open inlet faceplate............................................... 33 7.3 Opening inspection hatch...................................... 33 7.4 Lower battery......................................................... 34 8 Accessories..................................................... 35 We reserve the right to make changes without prior notice 03-04-2017 l i nda b | we si mpl i f y c onst ru ction Plexus 1.2 Symbols Hot water Cold water 2.4 Unloading of goods 10-25 kg ! Heavy Load - 2 man job It is recommended to use a “lift” for mounting. Hand-pull The beams and panels are normally delivered packed on wooden pallets. Lift the pallets carefully with a fork lift and place them on a dry and plain surface/ground. If the beams are delivered in single boxes, wooden blocks should be placed on the ground at one-metre intervals (or a pallet), before the boxes are been placed to store. Lindabs water products must be stored on a plane surface in a dry and well ventilated place, preferably indoors. If they have to be stored outdoors, protect them with a waterproof cover and store them protected from rain beneath a roof or other until they are fitted. 2.5 Handling / Carrying 2 Control of delivery 2.1 Before you start The beam or panel must be handled with care, ensuring that it will not be scratched or bended during transportation, preparation and installation. Read through the entire installation instruction before commencing installation in order to determine which parts that needs to be performed and in what order to be done. Always carry the beams or panels piecewise into the building. Keep the product in the package as long as you can. Lindab is a supplier of complete water products, but we offer also a wide range of accessories which suit perfectly to our water products simplifying your installation work, e.g. different type of hangers, Tektite-couplings, closing valves, thermostatic valves and actuators, flexible hoses, customized regulation components, customized cabeling and more. See also the separate document “Accessories”. Lindab will also provide you with a full ventilation system, with a wide range of Lindab Safe components. See also “Air Duct Systems”. 10-25 2.2 Safe operation kg ! Beware of sharp edges, especially of the coils. Always wear thin gloves and protective clothing. All existing safety regulations must be observed when working with Lindab water products. Check the weights of the beams or the panels with the installation instruction before carrying. 2.3 Receipt of goods Start by checking that the delivery is complete according to the order and that everything listed on the consignment note has been delivered. Then carry out a review of the products and make sure that nothing was damaged during transportation. If you discover damage that has occurred during delivery, it must be notified immediately. Lindab is not responsible for costs associated with the replacement of products that have been installed in any way other than shown in these installation instructions. Never use piping connections or edges to lift them, neither when you unpack them nor when you carry them towards the construction site. Do not place the product directly on the floor. Use the protective corners from package or other clean means from package to place the product before installation. Be careful if you must carry a long panel horizontally; if the panels are bended lengthwise, the profiles may be deformed and the piping could be loosen from the panel. When opening the box with a knife, be careful not to damage the product. Each beam is equipped with protective film to avoid any damage during transportation and handling on building site. The film needs to be removed before commissioning the products. We reserve the right to make changes without prior notice 03-04-2017 3 lin dab | w e s i m p l i fy c o n s t r u c t i o n Plexus 2.6 Tools To install the beam, panel or facade unit, the following tools are required. Knife Gloves Tape measure Pencil Spanner Drill machine Percussion drill Crowbar Tectite tool 12mm (Order no: 884087) Tectite tool small 12mm (Order no: 646881) Screwdriver Spirit level Lindab PC410 (Order no: 103344) Deburring tool Bits and drills Vacum cleaner Dust-cleaner 2.7 Installation It is important to use the correct hangers and the recommended amount for all installation principles. Different possible installation principles are shown in the installation instruction and hangers from Lindab should be used to ensure, that they are intended for the purpose and are safe to use. Lindab´s water products can be ordered, to be adapted to a wide range of different ceiling systems, please check installation instruction to ensure best adaptation. The Lindab water products should always be installed separately hanged up from the recessed ceiling. The weight of the product should not be covered by the ceiling system. Use plastic folio or other to protect the product during on site construction continually to keep the products in best condition and avoid any scratches. 4 Shoes with soft soles 2.8 Where to find additional instructions or technical documentation In the following chapters we will refer to additional technical documents or/and instructions by a certain keyword written as a link. If so you will easily find it with our Lindab Quick Selection Tool: www.lindqst.com 1. Visit www.lindqst.com 2. Select “documentation finder” 3. Select keyword (product name) 4. Follow the link 5. Find your document under “Related documents” 2.9 Cleaning after assembly/ before commissioning Please remember to remove plastic folio and other protection material before commissioning and clean the product before hand over. We reserve the right to make changes without prior notice 03-04-2017 l i nda b | we si mpl i f y c onst ru ction Plexus 2.10 Packing, unpacking guideline 10-25 kg ! We reserve the right to make changes without prior notice 03-04-2017 5 lin dab | w e s i m p l i fy c o n s t r u c t i o n Plexus 2.11 Product labelling Order : xx-xxxxx Pos : xx xx Plexus x-x-xx-xx-xxx-Xx Munio-I-xxx-12-125-AX Pressure: xx Pa AA x,xx m Flow: Project : xxxxxx xxxxxxxx xxxx-xxxx-xxxx xx-xx Mark : xxxxx xx Plugs : N/A xx Nozzles : N/A xx-xx Product ID : xxxxxxx xx l/s BB Sign. : xx ΔpStat [Pa] JetCones Plexus S60 0 120 1 2 3 Position of JetCone adjustment pins 4 5 6 7 8 9 100 1 3 Date Pstat [Pa] qa [l/s] 1 2 3 4 Signature Pos. 0-9 2 80 70 60 50 40 30 4 4 5 6 20 Rev. 04-2012 7 8 9 30 10 15 40 Plexus_label.indd 1 6 50 20 60 70 25 80 30 100 35 40 150 qa [l/s] qa [m3/h] 09-02-2016 14:15:56 We reserve the right to make changes without prior notice 03-04-2017 l i nda b | we si mpl i f y c onst ru ction Plexus 2.12 Order code Order : xx-xxxxx Pos : xx xx Plexus x-x-xx-xx-xxx-Xx Munio-I-xxx-12-125-AX Plexus I, (X, U, Y, Z) Pressure: xx Pa AA x,xx m Flow: Project : xxxxxx xxxxxxxx xxxx-xxxx-xxxx xx-xx Mark : xxxxx xx Plugs : N/A xx Nozzles : N/A Product ID : xx-xx xxxxxxx Plexus X I X Y Z X S* L* M* H* SA*** F Plexus F X XXX 12 60 62 67 120* 122* Sign. : xx XXX Ø12 (2 x 2 ) x2 60 120* x2 XXX 12 Plexus F xx l/s BB Ø125** Ø160** ( x1 ) XX XX XX Preset static pressure before nozzles [Pa] Preset airflow [l/s] XX XX A5 A6 B5 B6 A1 B1 XXX XX * 120 and 122 only available when S-configuration has been selected. L, M, H configurations only available in 60, 62, 67 versions. **ØH (Side air connection (A)) = 125 only. **ØV (Top air connection (B)) = 125 only for S-configuration. ØV = 160 only for L,M,H configurations. (See also dimension table 3.2). ***The type SA (integrated steel frame) is available for version ISA-60 and 120 only (for T24/T15 lay-in 600 (ceiling type 1) 2.13 Order code examples Order : xx-xxxxx Pos : xx Plexus I-S-60-12-125-A5 Munio-I-xxx-12-125-AX Pressure: AA Pa 60 Pa x,xx m Flow: Project : xxxxxx xxxxxxxx Mark : xxxxx xx N/A Nozzles : N/A Plugs : N/A Product ID : xxxxxxx Order : xx-xxxxx Pos : xx Plexus I-S-60-12-125-B6 Munio-I-xxx-12-125-AX Pressure: AA Pa 60 Pa x,xx m Flow: Project : xxxxxx xxxxxxxx Mark : xxxxx xx N/A Nozzles : N/A Plugs : N/A Product ID : xxxxxxx Order : xx-xxxxx Pos : xx Plexus F-S-60-12-125-A1 Munio-I-xxx-12-125-AX Pressure: AA Pa 60 Pa BB 24 l/sl/s Sign. : BB 24 l/sl/s Sign. : x,xx m Flow: Project : xxxxxx xxxxxxxx Mark : xxxxx xx N/A Nozzles : N/A Plugs : N/A Product ID : xxxxxxx BB 24 l/sl/s Sign. : Plexus I - S - 60 - 12 - 125 - A5 - 60 Pa - 24 l/s Plexus I - S - 60 - 12 - 125 - B6 - 60 Pa - 24 l/s Plexus F - S - 60 - 12 - 125 - A1 - 60 Pa - 24 l/s 2.14 Label Order : xx-xxxxx Pos : xx xx Plexus x-x-xx-xx-xxx-Xx Munio-I-xxx-12-125-AX On the label you will find: • • • • • • • Order: Order identification number. Pos: Order position. Product: Product configuration. Project: Project name. Mark: Marking noted on order. Product ID: Product number. Sign: To be signed when checked and commissioned on site. Pressure: xx Pa AA x,xx m Flow: Project : xxxxxx xxxxxxxx xxxx-xxxx-xxxx xx-xx Mark : xxxxx xx Plugs : N/A xx Nozzles : N/A Product ID : xx-xx xxxxxxx We reserve the right to make changes without prior notice 03-04-2017 xx l/s BB Sign. : xx 7 lin dab | w e s i m p l i fy c o n s t r u c t i o n Plexus 2.15 Contents of order 2.17 Accessories Standard package/order contains: Here you see some general accessories. For full range see separate Accessories document. • • • • Beam Plus features (pre-installed in factory) 4 pc/beam of copper insets (separate in smaller box) Accessories (separate in smaller box) Go to Accessories for details. Threaded rod kit M6/M8 2.16 Plus features x4 2.16.1 Inlet faceplates Order no: see Accessories Not relevant for Plexus 2.16.2 Outlet front grilles Not relevant for Plexus Flexible hoses 2.16.3 Integrated valves Order no: 680080 (0,4m push on, 12 and 12mm). See Accessories Transformer Go to TTR/TTV water valves for details. 2.16.4 Integrated Actuators Order no: see Accessories Tectite fittings Go to Actuators for details. Order no: 647690, 884050 and 884014 (12mm) see Accessories 2.16.5 Integrated Regula components Regula Combi Condensation sensor and Regula Secura LINDAB Heating link - S Cooling link - S Supply link - N Supply link - L Supply in - N Supply in 24V - L Heating link - S Cooling link - S Supply link - N Supply link - L Heating in - S Cooling in - S Supply out - N Supply out - L Cooling out - S Cooling out - N Cooling out - L Heating out - S Heating out - N Heating out - L Presence in - S Presence in - S Presence out - N Presence out - L Damper out - S Damper out - N Damper out - L RC in/out CO2 in - S CO2 in - S CO2 out - N CO2 out - L N = Neutral L = Load S = Signal Rc LINK Rc LINK Multi REGULA CONNECT Regula Multi connect card Go to Regula for details. 8 We reserve the right to make changes without prior notice 03-04-2017 l i nda b | we si mpl i f y c onst ru ction Plexus 3 Product specification 3.1 Product description The Plexus beam is a 360° comfort unit and is standardly prepared for ventilation and cooling (2-Pipe connection). It is available in an integrateable (I 60 / I 120) and an exposed version (F 60 / F 120). 3.2 Dimensions Plexus I, ( X, U, Y, Z ) Plexus F B mm ØH mm ØV mm I ( S/SA, L, M, H) 60 594 594 125 125/160 1, 2, 3, 8 X ( S, L, M, H) 60 599 599 125 125/160 4, 5, 6, 7, 14 U ( S, L, M, H) 60 599 599 125 125/160 USA 2’ x 2’ Y ( S, L, M, H) 60 575 575 125 B 125/160 9, 11 Z ( S, L, M, H) 60 584 584 125 125/160 B 10 I ( S, L, M, H) 62 619 619 125 I ( S/SA, L, M, H) 67 669 669 125 I S 120 594 1194 125 599 1199 B/2 21 125/160 31, 32 F ( S, L, M, H) 60 669 669 125 125/160 F S 120 669 1269 125 160 ! 1, 2, 3, 8 Plexus (F) - (S) => Øv = 125 4, 5, 6, 7, 14 70 17.5 Y S 120 575 1174 125 160 Z S 120 584 1183 125 B/2 160 U S 120 599 1209 125 160 USA 2' x 2' I S 122 619 1244 125 160 21 ! ØV mm 76.2 Øv 125/160 160 ØH mm A Øv Plexus (F) - (L, M, H) => Øv = 160 A Øv ØH 225 76.2 40 40 125 B mm 9, 11 ØH 225 X S 120 Øv 160 A mm Ceiling type 70 17.5 10 333 79 333 79 Plexus (I, X, U,Y, Z) - (L, M, H) => Øv = 160 Plexus (I, X, Y, Z) - (S) => Øv = 125 128 128 1111 4040 B 476 476 Øv Øv 220 220 ØHØH B 225 225 A mm 4949 40 40 A A 3.3 Plexus BB 480 (Plexus (Plexus120 120= =1080) 1080) 480 365 365 We reserve the right to make changes without prior notice 03-04-2017 9 lin dab | w e s i m p l i fy c o n s t r u c t i o n Plexus 3.4 Material data Type Plexus I 60 Plexus I 120 Plexus F 60 Plexus F 120 Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Weight, kg 11.6 Water content, cooling, l 1.0 1.3 1.0 1.3 Water content, heating, l 0.2 0.4 0.2 0.4 Water content, cooling only, l 1.2 1.3 1.2 1.3 EN 12735-2 CU-DHP EN 12735-2 CU-DHP EN 12735-2 CU-DHP EN 12735-2 CU-DHP Copper pipes, quality 18.6 20 17.2 28.9 30.3 3.5 Environmental Declarations 3.7 Water quality Please visit www.lindqst.com Lindab recommend water treatment and quality to be according to VDI 2035-2. • Select Documentation Finder • The water preparation and maintenance for the chilled beam water circuit must be handled by a specialist. • Select “Plexus” • Select “Related Documents” Building product declaration or Declaration of conformity. • To prevent corrosion, the water circuit must be airtight. 3.6 Working and test pressure Lindab’s waterborne products have been manufactured and tested according to Pressure Equipment Directive 97/237EC. The products are classified as SEP - Sound Engineering Practice. • The water system must also be equipped with aerators to remove any build-up air in the system. • The water must be oxygen free, to prevent corrosion. • The water system must be filled with potable water that complies with the “EC directive 98/83/EC”. • pH value of water must be between approximately 6-9 pH. Pressure table Pressure class PN10 Max. working pressure 10 bar Max. recommended dynamic pressure 0.2 bar Max. test pressure 16 bar • The water velocities should not exceed 1m/s, and should be kept as close to the nominal flow as possible to minimize noise and optimize the energy yield. • Use in-line strainers to remove dirt particles from the water. • If the water contains any additive inhibitor, then it must be appropriate to use with copper and solder. 3.8 Air quality Primary supply air have to be clean, dry and filtered before reaching the beam. 3.9 Capacity test Lindabs active chilled beams are Eurovent-certified and tested according to EN-15116. Please visit Plexus on www.lindqst.com and see Eurovent for more details. 10 We reserve the right to make changes without prior notice 03-04-2017 l i nda b | we si mpl i f y c onst ru ction Plexus 4 Connections 4.1. Water connections Flow indication arrows are shown on the inlet and return pipes in order to assist the installer. If the beam has been ordered with integrated valves, a special direction of the flow must be upheld to ensure correct flow through the thermostatic valve. Please note the flow direction indicator on the valve to insure correct installation in relation to the desired flow. When connecting a panel or a beam with the piping system either a push-on fitting or a compression coupling should be used. Lindab have tested and recommends push-on fittings from Tectite (which are available as accessory. See Accessories. To avoid sound being transported over the beam, we recommend to use flexible hoses between the piping and the beam connections. 4.1.1 Before installation • Notice! The connection pipes are internally soft-welded, therefore it’s not allowed to solder the beam to the pipes. For other than Lindab fittings and valves, please consult the installation guide for the specific fitting for further details on proper installation. • Both inlet- and return pipes are covered by a plastic or rubber protection cover, which must be removed before installation. • After removing the protection cover, make sure that the pipe is intact and undamaged, especially at the pipe end, as even small dents and scratches potentially pose a risk of leakage in the system. • Eventually deburr the pipe ends on the inside and the outside, using a deburring tool before installation. • Always remember to do a pressure test after assembly the pipe work. We reserve the right to make changes without prior notice 03-04-2017 11 lin dab | w e s i m p l i fy c o n s t r u c t i o n Plexus 4.1.2 Push-on fitting • Mount a push-on fitting to the pipe. Make sure to press the fitting all the way onto the pipe. Picture 8.b Push-on fitting on Picture 8.a Push-on fitting of • Mount a push-on valve to the pipe. Make sure the valve has the correct flow direction (see indication arrow on the valve) and that you have the correct valve, when integrated valve has been chosen (see indication on valve or follow cabelling to Regula Connect card). 4.1.3 Compression fitting • While mounting a compression fitting, the pipe will be exposed to a big amount of force, creating a risk of crushing the pipe. To ensure that the pipe will not be crushed when mounting the compression fitting, a copper insert must be inserted into the pipe (always part of the delivery). • The copper insert should be placed inside the pipe on the beam. Always support the copper pipe coil when inserting the copper insert into position. • Mount a compression coupling and/or a valve to the pipe. Don’t stress the nut too much, since this may crush the pipe. • Please refer to the suppliers manual. 4.1.4 Flexible hoses • Our flexible hoses can be used with both push-on and compression fitting. We recommend to use Tectite fittings, for easier and faster mounting. 12 We reserve the right to make changes without prior notice 03-04-2017 l i nda b | we si mpl i f y c onst ru ction Plexus 4.1.5 Additional Lindab accessories for water connections Valves and fittings Lindab TTR and TTV water valves The Lindab TTR and TTV valves must be used with all standard application chilled beams, radiant panels and facade units. The TTR and TTV valves ensures easy and fast installation thanks to the simple yet effective Tectite push-on connections. For further information, please see TTR/ TTV water valves documentation. Valves and Actuators installation When actuator and valves are ordered together with the Plexus and other Regula components, the cables are pre-connected to the Connect card / Secura from factory - (depending on your chosen solution). The actuator and valve is taped to the side of the Plexus and has to be connected to the correct water-pipe, turning the right way. Example Push on valve with Actuator installed on the battery’s cold water outlet. Valve arrow indicator must point in same direction as arrow on beam pipe label. Ballorex Dynamic For application in systems where pressure alterations may occur, the Ballorex Dynamic ensures an easy and precise dynamic flow regulation. Further information on request. Push on valve with air vent (aerator) If a waterborne unit is mounted in a location where issues with build up air may occur, applying an aerator is recommendable. As our aerators comes complete with Tectite fittings, installation is done in mere seconds. Order no: 647690 (12mm) Ballofix valves For easy closing off water connection pipes (available with or without handle). Order no: 642663 / 642662 (without handle, 12mm) For more details see: Accessories Actuators The actuator is a thermoelectric actuator for opening and closing valves on heating circuit distributors of concealed floor heating and cooling systems. Features, as protection in case of leaky valves, compact and modern casing, versions in normally closed and normally open, valve adapter concept and an enhanced life time makes the actuator competitive and flexible. The actuator is controlled by a room thermostat with two-point output or pulse-width modulation. See Actuators We reserve the right to make changes without prior notice 03-04-2017 13 lin dab | w e s i m p l i fy c o n s t r u c t i o n Plexus 4.1.6 Possible connections water cooling (2-pipe, Standard) 4.1.7 Possible connections water cooling and heating (4-pipe, Plus feature) All the Plexus active chilled beams are in the standard version equipped with a so called “2-pipe connection” and contain one water circuit (cooling). All Plexus’ can have a 4-pipe water connection (plus feature), which beside the cooling circuit also includes a heating circuit. The dimension for all water pipe connections are 12 mm. The dimension for all water pipe connections are 12 mm. Plexus 60 I, (X, U, Y, Z). Cooling. (Standard). Plexus 60. I, (X, U, Y, Z). Cooling and heating. 6 6 5 5 44 44 79 327 238 105 35 35 70 70 17.5 70 17.5 79 327 238 Plexus 120. I, (X, U, Y, Z). Cooling. (Standard). Plexus 120. I, (X, U, Y, Z). Cooling and heating. 327 238 327 238 385 192.5 35 385 192.5 87.5 70 70 105 Plexus I, (X, U, Y, Z). 60/120, cooling and heating. In /outs 60 14 120 We reserve the right to make changes without prior notice 03-04-2017 l i nda b | we si mpl i f y c onst ru ction Plexus Plexus F 60/120. Cooling. (Standard) Plexus F 60/120. Cooling and heating. 1 1 44 44 79 79 225 ØH 70 70 334,5 (Plexus F120 = 634,5) We reserve the right to make changes without prior notice 03-04-2017 17.5 333 55 79 B 17.5 B 334,5 (Plexus F120 = 634,5) 225 A Øv 15 lin dab | w e s i m p l i fy c o n s t r u c t i o n Plexus 4.2 Air connections 4.3 Possible combination of connections 4.2.1 Air connection installation The primary air supply must be connected with instructions from a ventilation specialist. Lindab’s chilled beams can beneficially be used together with Lindab’s Safe® duct systems. We recommend a flexible duct connection, like Lindab DRATMFU-125, to balance out different installation heights or directions between connection and duct and avoid sound will be diverted from piping system to the ceiling. B 6 A 5 I, (X, U, Y, Z) 60 / 120 4.2.2 Possible connections supply air B B A A 1 I, (X, U, Y, Z) 60 / 120 F 60 / 120 B A F 60 / 120 4.2.3 Possible connections exhaust air Not relevant for Plexus 16 We reserve the right to make changes without prior notice 03-04-2017 l i nda b | we si mpl i f y c onst ru ction Plexus 4.4 Electrical connections Electrical connections on the beam are only necessary, when plus features are chosen and thanks to the pre-fabrication it is as easy as “plug and play”. The components are always installed near the water-connection at the end of the beam. For further information, see Regula . 4.4.1 Regula components on the beam 5 1 Regula Secura Sensor Regula Convert Power Regula Convert Regula Sensor Philips Regula Secura 2 3 Regula Connect Cards Multi Pascal Basic REGULA CONNECT REGULA CONNECT REGULA CONNECT Multi Rc LINK N = Neutral L = Load S = Signal Pascal Rc LINK N = Neutral L = Load S = Signal Rc LINK Rc LINK RC in/out RC in / out CO2 in - S CO2 in - S CO2 out - N CO2 out - L CO2 in - S1 CO2 in - S2 CO2 out - N CO2 out - L Presence in - S Presence in - S Presence out - N Presence out - L Presence in - S1 Presence in - S2 Presence out - N Presence out - L Damper out - S Damper out - N Damper out - L Damper in - Pos Damper out - S Damper out - N Damper out - L Heating out - S Heating out - N Heating out - L Cooling out - S Cooling out - N Cooling out - L Heating in - S Cooling in - S Supply out - N Supply out - L Heating link - S Cooling link - S Supply link - N Heating 0-10V- S Heating 0-10V- N Heating 0-10V- L 4 Regula Combi Presence sensor Basic N = Neutral L = Load S = Signal Heating out - S Heating out - N Heating out - L Cooling out - S Cooling out - N Cooling out - L Heating in - S Cooling in - S Supply out - N Supply out - L Heating link_S Cooling link_S Supply link - N Supply link - L Heating link_S Cooling link_S Supply link - N Supply link - L Supply in - N Supply in - 24V - L LINDAB Supply Link2 - N Supply Link2 - L Supply Link1 - N Supply Link1 - L Supply in - N Supply in-24V - L LINDAB Supply link - L Heating link - S Cooling link - S Supply link - N Supply link - L Supply in - N Supply in 24V - L LINDAB (with protection covers, optional). We reserve the right to make changes without prior notice 03-04-2017 17 lin dab | w e s i m p l i fy c o n s t r u c t i o n Plexus 4.4.2 Example 1: Wiring scheme with Regula Connect multi Regula Combi Please visit www.lindqst.com and check out the “Wiring scheme configurator” for your set-up. REGULA CONNECT T568B T 21 22 40 32 31 41 ends must be insulated Regula Presence Power { White/Orange Orange White/Green Blue White/Blue Green White/Brown Brown 1 2 3 4 5 6 7 8 Regula Convert Multi Rc LINK N = Neutral L = Load S = Signal Rc LINK RC in/out CO2 in - S CO2 in - S CO2 out - N CO2 out - L Regula Sensor Philips Presence adapter 4 wire RJ11 6P4C, Straight through Presence in - S Presence in - S Presence out - N Presence out - L Damper out - S Damper out - N Damper out - L Actuator on/off 24V heating 23 24 11 10 To other Regula Connect Multi 1 2 4.4.3 Example 2: Wiring scheme with Regula Connect basic Bro Blu 24 V 4 5 230 V Bro Blu To other Regula Connect Multi Transformator Actuator on/off 24V cooling Condensation sensor 1 7 2 8 N L Blu Bro Blu Bro Whi Grn Bro Yel 4 3 2 1 4 3 2 1 Blu Bro Heating out - S Heating out - N Heating out - L Cooling out - S Cooling out - N Cooling out - L Heating in - S Cooling in - S Supply out - N Supply out - L Heating link - S Cooling link - S Supply link - N Supply link - L Heating link - S Cooling link - S Supply link - N Supply link - L Supply in - N Supply in 24V - L LINDAB Regula Combi REGULA CONNECT Basic N = Neutral L = Load S = Signal Actuator on/off 24V heating 23 24 11 10 To other Regula Connect Basic Condensation sensor 1 7 2 8 18 1 2 Bro Blu We reserve the right to make changes without prior notice 03-04-2017 24 V 4 5 230 V Bro Blu To other Regula Connect Basic Transformator Actuator on/off 24V cooling N L Blu Bro Blu Bro Whi Grn Bro Yel 4 3 2 1 4 3 2 1 Blu Bro Heating out - S Heating out - N Heating out - L Cooling out - S Cooling out - N Cooling out - L Heating in - S Cooling in - S Supply out - N Supply out - L Heating link_S Cooling link_S Supply link - N Supply link - L Heating link_S Cooling link_S Supply link - N Supply link - L Supply in - N Supply in - 24V - L LINDAB LINDAB Supply in - N Supply in 24V - L Heating link - S Cooling link - S Supply link - N Supply link - L Heating link - S Cooling link - S Supply link - N Supply link - L Heating in - S Cooling in - S Supply out - N Supply out - L Cooling out - S Cooling out - N Cooling out - L Heating out - S Heating out - N Heating out - L Damper out - S Damper out - N Damper out - L Presence in - S Presence in - S Presence out - N Presence out - L CO2 in - S CO2 in - S CO2 out - N CO2 out - L RC in/out Rc LINK N = Neutral L = Load S = Signal Rc LINK Multi REGULA CONNECT LINDAB Supply in - N Supply in-24V - L Supply Link2 - N Supply Link2 - L Supply Link1 - N Supply Link1 - L Heating 0-10V- S Heating 0-10V- N Heating 0-10V- L Damper in - Pos Damper out - S Damper out - N Damper out - L Presence in - S1 Presence in - S2 Presence out - N Presence out - L CO2 in - S1 CO2 in - S2 CO2 out - N CO2 out - L RC in / out Rc LINK N = Neutral L = Load S = Signal Rc LINK Pascal REGULA CONNECT 4.4.4 Regula Connect on the beam 4.4.6 Valves and Actuators on the beam Connect cards are pre-installed when the beam is ordered with PLUS-features. See Regula Connect for more details. Description, see 4.1.5. Regula Connect Basic The Regula Combi can be controlled and programmed locally in the display, or at a remote location by a EXOLINE or MODBUS communication system. Handles both 24V and 0-10V devices. LINDAB Supply in - N Supply in - 24V - L Heating link_S Cooling link_S Supply link - N Supply link - L Heating link_S Cooling link_S Supply link - N Supply link - L Heating in - S Cooling in - S Supply out - N Supply out - L Cooling out - S Cooling out - N Cooling out - L Heating out - S Heating out - N Heating out - L N = Neutral L = Load S = Signal Basic REGULA CONNECT l i nda b | we si mpl i f y c onst ru ction Plexus Regula Connect Pascal Regula Connect Multi 4.4.7 Regula Combi on/with the beam See the Regula Combi documentation. 4.4.8 Actuators Description, see 4.1.5. 4.4.5 Regula Secura on the beam Regula Secura is pre-installed when the beam is ordered with PLUS-features. See Regula Secura for more details. Condensation sensor and Regula Secura Cable to Regula Secura Condensation sensor We reserve the right to make changes without prior notice 03-04-2017 19 lin dab | w e s i m p l i fy c o n s t r u c t i o n Plexus 5 Installation of product 5.1 Handling of product For the handling of the product please refer to 2.5. 5.2 Ceiling systems 1 T24/T15 Lay-in 600 ( I-60 ) Water Danotile T24/T25 Echophon T24 Rockfon A24 595x595 2 T24/T15 Lay-in 600 not cleanable ( I-60 ) Water 3 Permanent ceiling ( I ) Water 6 Luxalon SQ Clip-In ( X ) Water 595x595 Frame follows the box ( X ) Water 5 Dampa Clip-in square edge ( X ) Water 600x600 600x600 8 Ecophon Focus DG 592x592 9 Rockfon E10 24 Ecophon - E / T24 ( Y ) Water 575x575 11 599x599 ( I ) Water chamfer 45°x3 10 ( X ) Water 15 7 Danotile Contur Ecophon D Rockfon D-XL chamfer 45°x5 13 600x600 16 26 4 Dampa Clip-in bevelled edge 8 10 Rockfon E10 15 Ecophon - E / T15 ( Z ) Water 11 Danotile Markant ( Y ) Water 14 Ecophon Focus DS Rockfon Sonar X ( X ) Water 599x599 584x584 21 T24/T15 Lay-in-625 ( I-62 ) Water 31 T24/T15 Lay-in-675 ( I-67 ) Water 22 T24/T15 Lay-in- 625 not cleanable ( I-62 ) Water 32 T24/T15 Lay-in- 675 not cleanable ( I-67 ) Water 619x619 20 669x669 We reserve the right to make changes without prior notice 03-04-2017 15 10 13 575x575 l i nda b | we si mpl i f y c onst ru ction Plexus 5.3 General installation principles 5.3.1 Recessed in suspended T-bar ceiling 5.3.4 Free hanging above perforated or eggcrate ceiling 5.3.2 Exposed, sealed to the ceiling 5.3.5 Recessed in suspended (permanent) ceiling 5.3.3 Exposed, free hanging 5.3.6 Recessed in suspended (permanent) ceiling without cover flanges We reserve the right to make changes without prior notice 03-04-2017 21 lin dab | w e s i m p l i fy c o n s t r u c t i o n Plexus 476 128 11 5.4 Preparation for installation on the product 40 Øv ØH The beam is prepared for installation by hangers (4 x per beam). 4 turnable/bendable brackets on the Plexus’ models ensures the possibility to use different hanger systems. 35 17.5 49 220 • Threaded rods M6/M8 Plexus 60 : 371 x 497mm Plexus 120 : 371 x 1097mm • Pendulum hangers (in different sizes) : 371 x 477mm: 371 x 1077mm : 371 x 477mm:40371 x 1077mm • Lindab FH-System (Gripple® - hang fast system) 70 1 x4 2 x4 3 x4 497 (Plexus 120 = 1097) A 371 22 We reserve the right to make changes without prior notice 03-04-2017 l i nda b | we si mpl i f y c onst ru ction Plexus A B C D E A B C D We reserve the right to make changes without prior notice 03-04-2017 23 lin dab | w e s i m p l i fy c o n s t r u c t i o n Plexus 5.5.1 Basics steps of installing the product Plexus Plexus Plexus Plexus Plexus Ceilingtype 1, 2, 8, 9 ,10, 11, 21, 22, 31, 32 (Plexus I, Y, Z) 8, 9, 10, 11 1, 2, 21, 22, 31, 32 A x4 C B 10-25 kg ! 24 S/SA-60 (1) I-62 (21, 22) I-67 (31, 32) Y (9, 11) Z (10) We reserve the right to make changes without prior notice 03-04-2017 x4 l i nda b | we si mpl i f y c onst ru ction Plexus Ceilingtype 3 Permanent ceiling, (Plexus I) Cutout dimensions in permanent ceilings: Plexus I (S/SA, L, M, H) 60 = Plexus I (S/SA) 120 = Plexus I-62 (S, L, M, H) = Plexus I-67 (S, L, M, H) = 544 x 544 mm 544 x 1144 mm 569 x 569 mm 619 x 619 mm 3 x4 A C x4 B 10-25 kg ! We reserve the right to make changes without prior notice 03-04-2017 25 lin dab | w e s i m p l i fy c o n s t r u c t i o n Plexus Ceilingtype 4, 5, 6, 7, 14 (Plexus X) 4, 5, 6, 7, 14 x4 A C B 10-25 kg ! 26 We reserve the right to make changes without prior notice 03-04-2017 x4 l i nda b | we si mpl i f y c onst ru ction Plexus Freehanging, exposed (Plexus F) A x2 B x4 C x4 D x4 E x4 F x2 We reserve the right to make changes without prior notice 03-04-2017 27 lin dab | w e s i m p l i fy c o n s t r u c t i o n Plexus 6 Adjustment and commissioning 6.1 Airflow and pressure The JetCone System enables an easy and fast adjustment in both pressure and air volume (primary airflow rate) through the front side. 6.1.1 Jetcone adjustment pins Plexus S/SA seen from below with faceplate of. Plexus L, M, H seen from below with faceplate of. Adjustment pins Adjustment pins Plexus S/SA Plexus L, M, H x4 x4 Fixed parts Fixed parts Pos. 4 Pos. 4 } Plexus S Plexus - S/SA pos. 0 28 Plexus L - M - H pos. 4 We reserve the right to make changes without prior notice 03-04-2017 } Plexus L, M, H nature l i nda b | we si mpl i f y c onst ru ction Plexus 6.1.2 Finding values for JetCone pins Example: Plexus-I-L-60-12-125-A5-70-16 ∆pstat = 70 Pa (Static pressure). qa = 16 (l/s) (Primary airflow rate) Δpstat [Pa] JetCones Plexus L60 0 120 1 2 3 Position of JetCone adjustment pins 4 5 6 7 8 9 100 1 3 Date Pstat [Pa] qa [l/s] 1 2 3 4 Signature 80 70 60 Pos. 0-9 2 50 40 4 30 4 5 6 20 Rev. 04-2012 7 8 9 10 30 15 40 50 20 60 70 25 80 30 35 100 Plexus_label.indd 3 Δpstat [Pa] 40 150 qa [l/s] qa [m3/h] 25-02-2016 15:48:12 Plexus L60 0 120 1 2 3 Position of JetCone adjustment pins 4 5 6 7 8 9 100 80 70 60 50 40 30 4 5 6 7 20 8 9 30 10 15 40 50 20 60 70 25 80 30 35 40 100 150 qa [l/s] qa [m3/h] 25-02-2016 15:48:12 6.1.3 Finding values for JetCone pins Symmetric adjustment Asymmetric adjustment 2 4 3 Keep average value as read in diagram. (=4) 6 We reserve the right to make changes without prior notice 03-04-2017 5 29 lin dab | w e s i m p l i fy c o n s t r u c t i o n Plexus 6.2 Adjustment of air distribution profile Plexus comes as standard (S) with fixed angled JetCone Nozzles and (L, M, H) with fixed air deflectors, which provide 360˚ optimal air distribution. 6.3 Measuring air pressure and calculating the air flow Before calculating the airflow, the static nozzle pressure must first be measured. The static nozzle pressure is the air pressure available at the nozzles. 6.3.1 Measuring static nozzle pressure and air pressure • To measure the air pressure, a manometer, ( analogue or digital ) will be needed. Lindab recommends PC410. • Insert the measuring tube onto the specialized measuring nozzle. • Read of the static nozzle pressure from the manometer (PC410). Lindab PC410 Order no: 103344 Pstat Room 6.3.2 Calculating the actual air flow • After measuring the static pressure, read the settings of the four JetCone adjustment pins to find the mean value of the pins. • Locate the diagram inside the openable perforated faceplate, (also see next page), and use the static nozzle pressure and the mean value of the pins to find the current airflow. 6.3.3 Changing the actual air flow • Measure the static nozzle pressure. • Locate the air pressure/airflow diagram inside the openable perforated faceplate. (Also see diagrams on next page). • Find the mean value of the 4 pins to reach the desired airflow, in the diagram. Use the static nozzle pressure and the desired airflow to find the mean value of the 4 pins. • Adjust the 4 pins in the Plexus, so the mean value of the pins will correspond with the mean value found in the diagram. • See example in 6.1.3 , asymmetric pin setting: 2 + 3 + 5 + 6 = 16/4 = 4 . ( Where (4) was the value read in diagram). 6.3.4 Changing the air distribution profile See 6.1.3. 30 We reserve the right to make changes without prior notice 03-04-2017 nature nature nature nature l i nda b | we si mpl i f y c onst ru ction Plexus 6.3.5 Plexus pressure / airflow diagrams Plexus S/SA60 S60 ΔpStat [Pa] Plexus 0 120 1 2 3 Position of JetCone adjustment pins 4 5 6 7 8 9 100 80 70 60 50 40 30 4 5 6 7 8 20 9 10 30 40 20 50 60 25 70 30 80 35 100 40 150 qa [l/s] qa [m3/h] 09-02-2016 14:15:56 Plexus Plexus S/SA120 S120 Δpstat [Pa] 15 0 120 1 2 3 Position of JetCone adjustment pins 4 5 6 35 40 7 8 9 100 80 70 60 50 40 30 8 9 10 30 11 13 40 15 50 20 60 25 70 80 100 50 60 150 200 70 250 qa [l/s] qa [m3/h] 09-02-2016 14:15:58 Plexus L60 Δpstat [Pa] 30 0 120 1 2 3 Position of JetCone adjustment pins 4 5 6 7 8 9 100 80 70 60 50 40 30 4 5 6 7 8 20 Δpstat [Pa] 9 10 30 15 40 20 50 Plexus M60 0 120 60 1 2 25 70 80 30 35 100 40 150 qa [l/s] qa [m3/h] 25-02-2016 Position of JetCone adjustment pins 15:48:12 3 4 5 6 7 8 9 100 80 70 60 50 40 30 10 15 40 50 20 60 70 25 80 30 100 35 40 150 50 60 200 qa [l/s] qa [m3/h] 09-02-2016 14:16:00 We reserve the right to make changes without prior notice 03-04-2017 31 lin dab | w e s i m p l i fy c o n s t r u c t i o n Plexus Δpstat [Pa] Plexus H60 0 1 120 Position of JetCone adjustment pins 2 3 4 5 6 7 8 9 100 Signature 80 70 60 50 40 30 20 70 25 80 90 30 35 40 100 50 150 60 200 70 250 80 300 qa [l/s] qa [m3/h] 09-02-2016 14:16:02 6.4 Water flow rate 6.4.1 Pre-setting of valves For the presetting of valves, please see the TTR/TTV water valves documentation. 6.4.2 Balancing strategy Lindab recommends always balancing the water system to guarantee thermal comfort in all areas, to avoid noise nuisance problems and to safe energy. A hydraulic balance is obvious to ensure that all the beams (panels or facade units) in the system will be always supplied with their required (planned) water flow rates (calculated with “Water Calculator on www. lindQST.com). Lindab refers to the proportional method, where all beams (panels or facade units) are balanced to the same proportion of the requested water flow rate (for example Broen, www.ballorex.com) 32 We reserve the right to make changes without prior notice 03-04-2017 l i nda b | we si mpl i f y c onst ru ction Plexus 7. Maintenance The interval of cleaning depends on the indoor environment where the beam is placed. Under optimal conditions the beams only need cleaning every 5 years. • • • • • • • Open the inlet plate using no tools (7.2) Clean the battery downside and the inlet faceplate inner parts with a dust cleaner / vacuum cleaner. Only use lukewarm water and a mild detergent and a piece of wet cloth to clean the inlet face plate. Open the inspection hatch (7.3) Clean the air plenum chamber and air connection with a vacuum cleaner Lower battery if water pipe connections are connected to system by flexhoses. ( Otherwise this is not possible, See7.4). Clean the top side of the battery, nozzle plate, JetCones and the mixing chamber with a dust cleaner / vacuum cleaner. 7.1 Remove the outlet front grille Not relevant for Plexus. 7.2 Open inlet faceplate 7.3 Opening inspection hatch Service wires We reserve the right to make changes without prior notice 03-04-2017 33 lin dab | w e s i m p l i fy c o n s t r u c t i o n Plexus 7.4 Lower battery Battery can only be lowered when the plus feature “dropdown battery” is ordered. A x2 M4x30 B B A ! A Do not unscrew completely! B x2 X Plexus 60 => X = 25 mm Plexus 120 => X = 15 mm Plexus 120 Plexus 60 C Flex-tubes Service wire 34 We reserve the right to make changes without prior notice 03-04-2017 l i nda b | we si mpl i f y c onst ru ction Plexus 8 Accessories Ask Lindab for the accessories mentioned in this document. Additional accessories (or additional dimensions) are available on request.** Order code Order number 2-way valve Broen TTR-12 Thermostatic valve - Tectite 647832 2-way valve Broen TTV-12 Thermostatic valve - Tectite 647834 Actuator A 40405 24 V on/off NC - 1m, non-halogen cable 684601 Actuator A 41405 24 V on/off NO - 1m, non-halogen cable 684603 Actuator APR 40405 0-10 V mod. NC, 1m, non-halogen cable 684667 Actuator APR 40405 0-10 V mod. NC, 1m, cable 684604 Ballofix Broen 12mm with handle - shut-off valve 642663 Ballofix Broen 12mm without handle - shut-off valve 642662 Ballorex dynamics 15mm Push-on 682474 Copper insert 12x1,0mm 884022 Lindab FHS-2-1000 (incl. M8 drop-in anchor) 100089 Flexible hose 0,4m push-on 12 and 12 mm 680080 Lindab PC 410 103344 Pendulum 180-300mm 642480 Pendulum 540-1000mm 646742 ** Regula Combi see: "Accessories" Regula Connect Card Basic */** Regula Connect Card Multi */** ** Regula Secura Aerator 12mm - tectite 647690 Tectite angle 12mm 884014 Tectite straight 12mm 884050 Tectite demounting tool 12mm 884087 Tectite demounting tool 12mm small 646881 4 pcs Threaded rod M8 -100mm + 4 pcs z-brackets + 16 pcs screw nuts on request 642531 Touch-up paint RAL 9010 - 10ml */** Transformer 24V AC output *see: ”Regula Connect – What do I get?” **see: ”Accessories” We reserve the right to make changes without prior notice 03-04-2017 35 At Lindab, good thinking is a philosophy that guides us in everything we do. We have made it our mission to create a healthy indoor climate – and to simplify the construction of sustainable buildings. We do that by designing innovative products and solutions that are easy to use, as well as offering efficient availability and logistics. We are also working on ways to reduce our impact on our environment and climate. We do that by developing methods to produce our solutions using a minimum of energy and natural resources, and by reducing negative effects on the environment. We use steel in our products. It’s one of few materials that can be recycled an infinite number of times without losing any of its properties. That means less carbon emissions in nature and less energy wasted. We simplify construction www.lindab.com
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement