ELECTRICAL SPECIFICATIONS:
Model No.
Volts
130B & 131B Series 120
131B & 131B Series w/240 suffi x
240
All are designed for AC service.
Watts
2000
2000
Amps
17.3
8.6
Hertz
60
60
Phase
1
1
NEMA
5-20P
6-15P
HOW TO INSTALL UNIT:
1. Place cabinet near warm ovens. Do NOT put in drafty areas or near ventilating systems.
2.
3.
Plug cord end into proper wall outlet.
Fill water pan if humidity is required.
Note: Pan holds 2 quarts (1.9 liters) of water.
HOW TO START UNIT:
1. Turn the POWER switch on. The yellow light will turn on.
2. Turn thermostat to #10.
3. Preheat cabinet for 30 minutes.
4. Put food into cabinet.
5. Turn thermostat to #8 and close door.
Note: No. 8 setting = approx. 175°F (79°C).
No. 6 setting = approx. 145°F (63°C).
No. 4 setting = approx. 115°F (46°C).
Proper food holding temperature is
140°F (60°C or higher.
The thermometer shows the temperature inside.
TO TURN OFF UNIT:
1. Turn thermostat off.
2. Turn the POWER switch off. The yellow light will go out.
1 2
5
PARTS IDENTIFICATION
1. Power Switch
2. Thermostat
3. Temperature Display
4. Heater
5. Water Pan w/cover
4
3
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Hot Cabinet
Rev. 5 (3/10)
FL-1390-3
Page 2 of 4
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Models: 130B and 131B Series Hot Cabinets
MAINTENANCE
HOT UNIT REMOVAL INSTRUCTIONS:
1. Unplug power cord from wall outlet.
2. Remove screw from back of cabinet located just above the cord.
3. Slide the entire unit out the front of the cabinet.
HOW TO CLEAN THE CABINET:
BEFORE cleaning
WARNING
the cabinet:
1. Allow cabinet to cool.
2. Remove Hot unit from cabinet.
3. Do NOT use abrasives or harsh chemicals.
Cleaning hints:
1. Wipe up spills as soon as possible.
2. Clean cabinet regularly to avoid heavy dirt build-up.
3. Make a test spot with cleaner.
4. Follow manufacturer’s directions on cleaner.
5. Do not mix cleaners.
6. Avoid drips and splashes.
HOW TO CLEAN THE UNIT:
CABINET and DOOR
(Aluminum)
Inside and
Outside
Soil Cleaner Method
DIRT
FINGERPRINTS,
GREASE and OIL
Mild *detergent and hot water, or mild abrasive cleaner.
Steam (no strong alkaline additive)
Chemical oven cleaner for aluminum
1. Use soft, damp cloth.
2. Rinse with hot water.
3. Wipe dry
1. Rinse after steam cleaning.
2. Wipe dry.
Follow oven cleaner manufacturer’s directions.
Mild abrasive cleaner; oily or waxy cleaner.
Mild abrasive cleaner
Apply with soft, clean cloth.
WATER SPOTS 1. Apply with damp cloth.
2. Rinse and dry.
*Mild detergents include soaps and non-abrasive cleaners.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Hot Cabinet
Rev. 5 (3/10)
FL-1390-3
Page 3 of 4
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Models: 130B and 131B Series Hot Cabinets
TROUBLE-SHOOTING CHART:
FAILURE
1. Yellow light at switch does not light.
2. Unit does not heat.
3. Unit gets too hot or won’t shut off.
4. Blower does not work or makes noise.
POSSIBLE CAUSE
1a. Circuit breaker/fuse to wall outlet is blown.
1b. Cord is unplugged from wall outlet or cabinet.
1c. Switch is “OFF”.
2a. Thermostat set too low or is “OFF”.
2b. Water in pan may be low.
2c. Switch is “OFF”.
3a. Defective electrical parts.
UNPLUG UNIT FROM WALL OUTLET.
4a. Defective blower.
Note: Optional digital thermometer will fl ash if cabinet temperature is below 140°F or above 250°F.
Call the factory if you need different settings.
If cause is none of the above, refer to our list of Authorized Service Centers, FL-1400.
Instructions for replacing parts are included in replacement parts kits.
REPLACEMENT PARTS:
DESCRIPTION 120 VOLT 240 VOLT
Hot Unit ..................................................... HU-18-1254-44 ............ HU-18-1254-45
Air Tunnel .................................................. 6217 .............................. 6217
Water Pan, Complete ................................. 1017-001-03 ................. 1017-001-03
Water Pan, Pan only ................................... 1017-010 ...................... 1017-010
Blower Kit ................................................. 0769-005-K .................. 0769-006-K-1
Blower Motor Cover .................................. 1253-289 ...................... 1253-289
Card Clip .................................................... 5258-010 ...................... 5258-010
Heater Kit ................................................... 0811-022-K .................. 0811-023-K
Latch, Gravity type .................................... 1136-K .......................... 1136-K
Power Cord ................................................ 0810-093 ...................... 0810-039
Power Switch ............................................. 0808-116 ...................... 0808-116
Pilot Light .................................................. 0766-094 ...................... 0766-095
Terminal Block (Front, power) .................. 0852-091 ...................... 0852-091
Terminal Block (Rear) ............................... 0978-007-K .................. 0978-007-K
Thermostat Kit ........................................... 0848-062-K .................. 0848-062-K
Thermometer Kit (Analog) ........................ 5238-030-K .................. 5238-030-K
Thermometer Kit (Digital °F) .................... 5238-034-K .................. 5238-034-K
Thermometer °F only ............................ 5238-034 ...................... 5238-034
Transformer, 110/220V only ................. 0769-159 ...................... 0769-159
Thermometer Kit (Digital °C) ................... 5238-034-K1 ................ 5238-034-K1
Thermometer °C only ........................... 5238-034-1 ................... 5238-034-1
Transformer, 110/220V only ................. 0769-159 ...................... 0769-159
Timer .......................................................... 0849-008-K .................. 0849-009-K
Wiring Harness .......................................... 5812-899
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Hot Cabinet
Rev. 5 (3/10)
FL-1390-3
Page 4 of 4
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Models: 130B and 131B Series Hot Cabinets
5-20P
120V, 20A
GREEN
G
G
W
6-15P
240V, 15A
GREEN
G
G
W
BROWN
1 2
SLEEVING
TERMINAL
BLOCK
BLUE
5 12
HEATER
BLOWER
FOR 220V
TRANSFORMER
110V/220V
50
4 3
52
2
51
1
8 5
50
51 t°
SENSOR
DIP SWITCH (SW1)
SETTINGS
1 2 3
OFF
F°
OFF
C°
FOR 120V
TRANSFORMER
110V/220V
4 3
50
2
51
1
8 5
50
51
3
TERMINAL
BLOCK
1
2
3
4
11
5
11
THERMOSTAT t°
SENSOR
WIRE HARNESS 5812-918
OPTIONAL
14
13
ELECTRICAL SPECS.
Model 1254-044
2075W, 120V, 60 Hz, 1 Ph
AC Service
Model 1254-045
2075W, 240V, 60 Hz, 1 Ph
AC Service