Endless Pools SwimCross Owner's Manual

Add to My manuals
28 Pages

advertisement

Endless Pools SwimCross Owner's Manual | Manualzz

SwimCross

Exercise Systems

by Endless Pools

®

OWNER'S MANUAL

WELCOME

Watkins Manufacturing Corporation congratulates you on your decision to enjoy the finest SWIMCROSS

Exercise System available. Welcome to the growing family of SWIMCROSS Exercise System by

ENDLESS POOLS owners.

OWNER’S MANUAL

This Owner’s Manual will acquaint you with the operation and general maintenance of your new

SWIMCROSS Exercise

System. We suggest that you take some time to carefully review all sections. Please keep this manual available for reference.

If you have questions about any aspect of your SWIMCROSS Exercise System’s set-up, operation or maintenance, contact your authorized ENDLESS POOLS dealership. They are trained professionals who are familiar with the product, as well as new SWIMCROSS Exercise System ownership concerns. Their expertise will facilitate the enjoyment of your new

SWIMCROSS Exercise System.

The serial number/identification label is located within the equipment compartment of your SWIMCROSS Exercise System.

The serial number should also be documented on the delivery receipt from your dealer.

IMPORTANT: Watkins Manufacturing Corporation reserves the right to change specifications, or design, without notification and without incurring any obligation.

DATE PURCHASED: ___________________________________

DATE INSTALLED: _____________________________________

DEALER: ____________________________________________

ADDRESS: ___________________________________________

TELEPHONE: _________________________________________

MODEL/SERIAL NUMBER: ______________________________

COVER SERIAL NUMBER: ______________________________

In most cities and counties, permits will be required for the installation of electrical circuits or the construction of exterior surfaces (decks and gazebos). In addition, some communities have adopted residential barrier codes which may require fencing and/or self-closing gates on the property to prevent unsupervised access to the

SWIMCROSS

Exercise System by children. As a general practice, your local Building Department will inform you of any applicable barrier requirements at the time a permit is obtained for the installation of an electrical circuit. Your ENDLESS POOLS dealer can provide information on which permits may be required.

SAFETY INFORMATION

IMPORTANT SAFETY INSTRUCTIONS ..............................1

IMPORTANT SWIMCROSS EXERCISE SYSTEM

INSTRUCTIONS .....................................................................3

SITE REQUIREMENTS

INDOOR CONSIDERATIONS ...............................................4

OUTDOOR CONSIDERATIONS ...........................................4

ELECTRICAL REQUIREMENTS

230 VOLT PERMANENTLY CONNECTED ..........................5

EQUIPMENT COMPARTMENT ............................................6

DOOR PANEL REMOVE & REPLACE .................................6

GETTING STARTED

MAIN SWIMCROSS EXERCISE SYSTEM FEATURES .....7

HYDROMASSAGE JETS.......................................................8

SWIM JETS .............................................................................8

WATERFALL VALVE ...............................................................8

AIR CONTROLS .....................................................................8

QUICK START-UP INSTRUCTIONS ....................................8

OPERATING INSTRUCTIONS

CONTROL PANEL ................................................................10

SETTINGS .............................................................................10

AUDIO IN.STREAM (OPTIONAL) .......................................12

TEMPERATURE CONTROL ..............................................12

JETS CONTROL ...................................................................13

LIGHT CONTROL .................................................................13

FILTER CYCLES ...................................................................13

ALL OFF / MEMORY ON .....................................................13

WI-FI IN.TOUCH™ (OPTIONAL) .......................................13

TABLE OF CONTENTS

WATER QUALITY AND MAINTENANCE

BASIC INFORMATION .........................................................14

CHEMICAL SAFETY ...........................................................14

HOW TO ADD CHEMICALS

TO THE WATER....................................................................14

FUNDAMENTALS OF

WATER MAINTENANCE .....................................................14

THE

ENDLESS POOLS

WATER MAINTENANCE

PROGRAM ............................................................................16

VACATION WATER CARE INSTRUCTIONS .....................17

GLOSSARY ...........................................................................18

CARE AND MAINTENANCE

FILTER MAINTENANCE ......................................................19

FILTER CARTRIDGE REMOVAL AND CLEANING

INSTRUCTIONS ...................................................................19

DRAINING YOUR SWIMCROSS EXERCISE SYSTEM ...20

PREVENTION OF FREEZING ............................................20

WINTERIZING YOUR SWIMCROSS EXERCISE

SYSTEM ................................................................................20

CARE OF THE PILLOWS ...................................................20

CARE OF THE EXTERIOR ..................................................21

SERVICE INFORMATION

GENERAL INFORMATION ..................................................22

GFCI AND HIGH LIMIT THERMOSTAT ..............................22

MISCELLANEOUS SERVICE INFORMATION ..................22

ACTS INVALIDATING WARRANTY ....................................22

DISCLAIMERS ......................................................................23

WATKINS CUSTOMER SERVICE ......................................23

TROUBLESHOOTING .........................................................23

S afety

I nformatIon

IMPORTANT SAFETY

INSTRUCTIONS

(READ AND FOLLOW ALL

INSTRUCTIONS)

AVOIDING THE RISK TO CHILDREN

DANGER - RISK OF CHILD DROWNING

Extreme caution must be exercised to prevent unauthorized access by children. To avoid accidents, ensure that children cannot use a

SWIMCROSS Exercise System unless they are supervised at all times.

NO DIVING

Danger: Diving May Result in serious injury or death.

• Do not connect any auxiliary components (for example, cable, additional speakers, headphones, additional audio components) to the audio system unless approved by Watkins Manufacturing Corporation

• Do not self service the audio component by opening or removing

SWIMCROSS Exercise System door panel as this may expose dangerous voltage or other risk of injury. Refer all servicing to qualified service personnel.

• Do not attach an external antennae to a

SWIMCROSS Exercise

System audio system unless installed by a licensed electrician in accordance with Article 810 of the National Electric Code, ANSI/NFPA

70.

WARNING

To reduce the risk of injury, do not permit children to use this

SWIMCROSS Exercise System unless they are closely supervised at all times.

• To reduce the risk of injury, lower water temperatures are recommended for young children. Children are especially sensitive to hot water.

• Extreme caution must be exercised to prevent unauthorized access by children. To avoid accidents, ensure that children cannot use the

SWIMCROSS Exercise System unless they are supervised at all times.

DO:

• Make sure you always lock any child resistant locks after using the

SWIMCROSS Exercise System for your children’s safety.

• Test the water temperature with your hand before allowing children to enter the

SWIMCROSS Exercise System to be sure that it’s comfortable.

• Remind children that wet surfaces can be very slippery. Make sure that children are careful when entering or exiting the SWIMCROSS

Exercise System.

DON'T:

• Allow children to climb onto a SWIMCROSS Exercise System cover.

• Allow children to have unsupervised access to the

SWIMCROSS

Exercise System.

AVOIDING THE RISK OF ELECTROCUTION

DANGER - RISK OF ELECTROCUTION

• Connect only to a grounded source.

• Do not bury the power cord. A buried power cord may result in death, or serious personal injury due to electrocution if direct burial-type cable is not used, or if improper digging occurs.

• A ground terminal (pressure wire connector) is provided on the control box inside the unit to permit connection of a minimum No. 6 AWG

(16 mm²) solid copper bonding conductor between this point and any metal equipment, metal water pipe, metal enclosures of electrical equipment, or conduit within five feet (1.5 m) of the unit as needed to comply with local requirements.

WARNING

• To reduce the risk of electrical shock, replace a damaged cord immediately. Failure to do so may result in death or serious personal injury due to electrocution.

• Your SWIMCROSS Exercise System is provided with a Ground

Fault Circuit Interrupter (GFCI) for user and equipment protection. To ensure proper operation of this important safety device, test according to the following instructions:

• A ground terminal is provided inside the junction box. To reduce the risk of electric shock, connect this terminal to the grounding terminal of your electrical service or supply panel with a continuous green, insulated copper wire. The wire must be equivalent in size to the circuit conductors supplying the equipment. In addition, a bonding terminal (pressure wire connector) is provided on the outside of the control box/heater for bonding to local ground points. To reduce the risk of electric shock, this connector should be bonded with a No. 6 AWG (16 mm

²

) solid copper wire to any metal ladders, water pipes, or other metal within 5 feet (1.5 m) of the SWIMCROSS Exercise System to comply with local requirements. The means of disconnection must be readily accessible, but must be installed at least 5 feet (1.5 m) from the

SWIMCROSS Exercise System.

• Your SWIMCROSS Exercise System is provided with a suitably rated circuit breaker to open all ungrounded supply conductors.

• Your SWIMCROSS Exercise System uses ground fault circuit interrupters in the electrical subpanel. Before each use of the

SWIMCROSS Exercise System and with the unit operating, push the TEST button on each breaker. The switch should click over to the “Trip” position. Wait 30 seconds and reset each GFCI breaker by switching it completely off and then completely on. The switch should then stay on. If either of the interrupters does not perform in this manner, it is an indication of an electrical malfunction and the possibility of an electric shock. Disconnect the power until the fault has been identified and corrected.

DANGER - RISK OF ELECTRICAL SHOCK

• Install at least 5 feet (1.5 m) from all metal surfaces. A SWIMCROSS

Exercise System may be installed within 5 feet of a metal surface if each metal surface is permanently connected by a minimum No. 8

AWG (10 mm

²

) solid copper conductor attached to the wire ground

Safety Information

Page 1

connector on the heater terminal block that is provided for this purpose.

• Install your SWIMCROSS Exercise System is such a way that drainage is away from the electrical compartment and from all electrical components.

• Do not permit any electrical appliances, such as a light, telephone, radio, or television within 5 feet (1.5 m) of a SWIMCROSS Exercise

System. Failure to maintain a safe distance may result in death, or serious personal injury due to electrocution, if the appliance should fall into the SWIMCROSS Exercise System.

DO:

• Be sure your SWIMCROSS Exercise System is connected to the power supply correctly - use a licensed electrical contractor.

• Disconnect the SWIMCROSS Exercise System from the power supply before draining the

SWIMCROSS Exercise System or servicing the electrical components.

• Test the Ground Fault Circuit Interrupter(s) before each use.

• Replace audio components only with identical components (if your SWIMCROSS Exercise System is equipped with an audio component).

DON'T:

• Use the SWIMCROSS Exercise System with the equipment compartment door removed.

• Place electrical appliances within 5 feet (1.5m) of the SWIMCROSS

Exercise System.

• Use an extension cord to connect the SWIMCROSS Exercise System to its power source. The cord may not be properly grounded and the connection is a shock hazard. An extension cord may cause a voltage drop, which will cause overheating of the jet pump motor and motor damage.

• Attempt to open the electrical control box. There are no user serviceable parts inside.

RISKS TO AVOID

DANGER - RISK OF INJURY

• To reduce the risk of injury to persons, DO NOT remove suction fittings

(filter standpipes) located in the filter compartment.

• The suction fittings in the

SWIMCROSS Exercise System are sized to match the specific water flow created by the pump. Never replace a suction fitting with one rated less than the flow rate marked on the original suction fitting.

• There is a danger of slipping and falling. Remember that wet surfaces can be very slippery. Take care when entering or exiting the

SWIMCROSS Exercise System.

• Never operate SWIMCROSS Exercise System if the suction fittings are broken or missing.

• People with infectious diseases should not use the SWIMCROSS

Exercise System.

• Keep any loose articles of clothing, long hair, or hanging jewelry away from rotating jets or other moving components. Long hair should be tied up or placed under a bathing cap.

• Safe water temperature for aquatic exercise is approximately

85°F (29.5°C).

• DO NOT use this SWIMCROSS Exercise System alone.

Page 2

INCREASED SIDE EFFECTS OF MEDICATION

• The use of drugs or alcohol may cause unconsciousness with the possibility of drowning.

• Persons using medications should consult a physician before using a

SWIMCROSS Exercise System; some medication may cause a user to become drowsy, while other medication may affect heart rate, blood pressure, and circulation.

• Persons taking medications which induce drowsiness, such as tranquilizers, antihistamines, or anticoagulants should not use the

SWIMCROSS Exercise System.

HEALTH PROBLEMS AFFECTED BY SWIMCROSS

EXERCISE SYSTEM USE

• Pregnant women should consult a physician before using

SWIMCROSS Exercise System.

• Persons suffering from obesity, or with a medical history of heart disease, low or high blood pressure, circulatory system problems, or diabetes should consult a physician before using SWIMCROSS

Exercise System.

UNCLEAN WATER

• Keep the water clean and sanitized with correct chemical care. The recommended levels for your ENDLESS POOLS SWIMCROSS

Exercise System are:

Free Available Chlorine:

1.0-5.0 ppm

Water pH:

7.2-7.8

Total Alkalinity:

80-120 ppm

Calcium Hardness:

50-150 ppm

• Refer to Water Quality and Maintenance section for complete instructions.

IMPORTANT: Turn on the jet pump for a least ten minutes after adding

ANY SWIMCROSS Exercise System water chemicals into the filter compartment.

Clean the filter cartridges monthly to remove debris and mineral buildup which may affect the performance of the hydromassage jets, limit the flow, or trip the high limit thermostat, which will turn off the entire

SWIMCROSS Exercise System.

AVOIDING THE RISK OF HYPERTHERMIA

Prolonged immersion in hot water can result in HYPERTHERMIA, a dangerous condition which occurs when the internal temperature of the body reaches a level above normal 98.6°F (37°C). The symptoms of hyperthermia include unawareness of impending hazard, failure to perceive heat, failure to recognize the need to exit the SWIMCROSS

Exercise System, physical inability to exit the SWIMCROSS Exercise

System, fetal damage in pregnant women, and unconsciousness resulting in a danger of drowning.

WARNING

The use of alcohol, drugs, or medication can greatly increase the risk of fatal hyperthermia in SWIMCROSS Exercise Systems.

Safety Information

TO REDUCE THE RISK OF INJURY

• The water in the SWIMCROSS Exercise System should never exceed 104°F (40°C). Water temperatures between 79°F and 104°F

(26°C and 40°C) are considered safe for a healthy adult. The lower water temperatures are recommended for extended use (exceeding ten minutes) and for young children. Extended use can cause hyperthermia.

• Pregnant or possibly pregnant women should limit SWIMCROSS

Exercise System water temperatures to 85°F (29.5°C) consult a physician prior to using this product. Failure to do so may result in permanent injury to your baby.

• Do not use

SWIMCROSS Exercise System having water temperatures over 100°F (36°C) immediately following strenuous exercise.

• Keep all breakables, especially glass, away from this SWIMCROSS

Exercise System.

• Never insert any objects into any openings.

• Keep all chemicals away from children and pets.

• DO NOT stack chemicals on top of one another.

• NEVER MIX CHEMICALS.

• Sanitizing chemicals must be stored separately from balancing chemicals.

AVOIDING THE RISK OF SKIN BURNS

• To reduce the risk of injury, before entering a SWIMCROSS Exercise

System the user should measure the water temperature with an accurate thermometer.

• Test the water with your hand before entering the SWIMCROSS

Exercise System to be sure it’s comfortable.

SAFETY SIGN

Each ENDLESS POOLS SWIMCROSS Exercise System is shipped with a SAFETY SIGN in the owner’s package. The sign, which is required as a condition of Product Listing, should be permanently installed where it is visible to the users of the SWIMCROSS Exercise

System. To obtain additional SAFETY SIGNS, contact your

ENDLESS

POOLS dealer. Safety labels that are affixed to the shell are intended to be permanent and should not be removed.

IMPORTANT

SWIMCROSS EXERCISE

SYSTEM INSTRUCTIONS

The following contains important SWIMCROSS Exercise System information, and we strongly encourage you to read and apply them.

DO:

• Follow the SWIMCROSS Exercise System Care and Maintenance recommendations stated in this manual.

• Use only approved accessories and recommended SWIMCROSS

Exercise System chemicals and cleaners.

Safety Information

DON'T:

• Leave the SWIMCROSS Exercise System exposed to the sun without water or a cover in place. Exposure to direct sunlight can cause solar distress of the shell material.

• Roll or slide the SWIMCROSS Exercise System on its side. This will damage the siding.

• Lift or drag the vinyl cover by using the cover lock straps; always lift or carry the cover by using the handles.

• Attempt to open the electrical control box. There are no user serviceable parts inside. Opening of the control box by the

SWIMCROSS Exercise System owner will void the warranty. If you have an operational problem, carefully go through the steps outlined in the Troubleshooting section. If you are not able to resolve the problem, contact your authorized ENDLESS POOLS dealer. Many problems can easily be diagnosed over the telephone by an Authorized Service

Technician.

SWIMCROSS EXERCISE SYSTEM SHELL

Your SWIMCROSS Exercise System has an acrylic shell. Stains and dirt generally will not adhere to your SWIMCROSS Exercise System’s surface. A soft rag should easily remove most dirt. Most household chemicals are harmful to your SWIMCROSS Exercise System’s shell

(see below for detailed information on cleaning agents). Always rinse off any SWIMCROSS Exercise System shell cleaning agent with fresh water.

IMPORTANT:

1. The following products are the ONLY approved cleaning agents for your SWIMCROSS Exercise System shell: plain water, Brillianize

® or Soft Scrub

®

. The use of alcohol or any other household cleaner other than those listed to clean the SWIMCROSS Exercise System shell surface is NOT recommended. DO NOT use any cleaning products containing abrasives or solvents since they may damage the shell surface, specifically: Simple Green

®

, Windex

®

or spa Mitt.

NEVER USE HARSH CHEMICALS! Damage to the shell by use of harsh chemicals is not covered under the warranty. Always rinse off any SWIMCROSS Exercise System shell cleaning agent with fresh water.

2. Iron and copper in the water can stain the SWIMCROSS Exercise

System shell if allowed to go unchecked. Ask your

ENDLESS

POOLS dealer about a Stain and Scale Inhibitor to use if your

SWIMCROSS Exercise System has a high concentration of dissolved minerals.

3. Keep all cleaners out of the reach of children and use care when applying.

SAVE THESE INSTRUCTIONS

Page 3

S

Ite requIrementS

Your

SWIMCROSS

Exercise System must be installed on a smooth and level surface that can support 190 lbs per square foot.

If a new slab is poured, consult your local electrical codes regarding grounding and bonding. Local code may require a bonding wire to be attached to the reinforcing bar or wire mesh that is embedded in the concrete. If new concrete is being poured, this is the ideal time to install the conduit for the incoming electrical supply.

Even if a new pad has been poured, it is essential that the system site is level and planar. There is a simple way to ensure that this is the case. First, draw a chalk outline of the footprint of your

SWIMCROSS

Exercise System. Place a six-foot level along and around the footprint of the system. Verify that there are no gaps between the level and floor.

Next pour water inside of the chalk footprint. Verify that the water does not puddle inside the footprint.

Should there a be a gap or should the water puddle inside the footprint, call your ENDLESS POOLS dealer prior to continuing to discuss the best way to resolve this situation.

INDOOR CONSIDERATIONS

1. Local electrical and plumbing codes.

2. Ventilation fans and/or dehumidifiers should be provided to handle the humidity developed by your

SWIMCROSS

Exercise System.

Walls, ceiling and wood trim should be water resistant, also.

3. Chemicals will vaporize from the water and may cause an odor and possibly corrosion to certain home hardware. Never store chemicals inside the

SWIMCROSS

Exercise System cabinet.

4. During the normal use of the

SWIMCROSS

Exercise System, water will escape the vessel. Never place on or over any materials, which may be damaged by this water or the chemicals within the water. Keep damageable materials far enough away to avoid water damage, even if the

SWIMCROSS

Exercise System should lose all its water.

5. Consider and prepare for the unlikely event of rapid drainage. If placement of the

SWIMCROSS

Exercise System is permanent, you may wish to provide floor drains to accommodate draining, etc.

Always leave room all around the

SWIMCROSS

Exercise System for easy access in case repairs are necessary.

6. Consider and prepare for the unlikely event of removal.

7. Do not set

SWIMCROSS

Exercise System on finished floor without a waterproof barrier protection underneath.

8. The

SWIMCROSS

Exercise System should have access to a power source capable of supplying 230 volts AC power. It must be wired directly into a grounded circuit with a ground fault circuit interrupter (GFCI). No other appliances should be on the same circuit.

9. The

SWIMCROSS

Exercise System should be close to a source of water.

10. Be sure that the location you choose is stable. It must be able to support the weight of the

SWIMCROSS

Exercise System when it is filled with water, plus the weight of the occupants. The

SWIMCROSS

Exercise System may weigh up to 18,185 lbs

(8,265 kg) when it is filled with water.

11. Do not use the

SWIMCROSS

Exercise System above a finished living area due to the risk of water damage.

Page 4

12. The

SWIMCROSS

Exercise System is not designed for in-floor installation. However, it is compatible with a deck system that is built flush with the bar top, provided you leave access for service.

13. Be sure to note any other considerations, such as aesthetics or privacy concerns that may affect the safety or enjoyment of using the

SWIMCROSS

Exercise System.

OUTDOOR CONSIDERATIONS

1. Local electrical and plumbing codes.

2. Consider local codes pertaining to fencing, enclosures, walls, electrical and plumbing. You will need to ensure that your

SWIMCROSS

Exercise System is an adequate distance from power lines, both above ground and underground. Your

SWIMCROSS

Exercise System will also need to be child proofed.

3. View from house for aesthetics and supervisory needs.

4. Distance from house for wintertime soaking.

5. Nighttime lighting.

6. Consider sunlight exposure, views, access, property lines, lighting, wind direction, shielding, septic tanks, plants, and trees when determining your location. Chemicals in the

SWIMCROSS

Exercise System water may splash damaging nearby plant life.

7. If your

SWIMCROSS

Exercise System is to be located on a second story, be positive support is adequate. Call your builder and a structural engineer.

8. Area for placement of support equipment where adequate space will be needed to gain access to components for maintenance and general servicing.

9. Be sure to note any other considerations, such as aesthetics or privacy concerns that may affect the safety or enjoyment of using the

SWIMCROSS

Exercise System.

10. Provide adequate drainage away from the equipment and adequate elevation to allow draining by siphon, if should be required.

11. Location of electrical supply. 230-volt systems require hard wire installed from the main electrical source, to the sub panel, then to the

SWIMCROSS

Exercise System terminal block. All equipment must be ground fault circuit protected (NOT SUPPLIED) . All electrical wiring must comply with the national electric code.

12. Locations at least 5 ft (1.52 m) from all metal surfaces. A

SWIMCROSS

Exercise System may be installed within 5 feet of metals surfaces providing each metal surface is permanently connected by a no. 8 awg (8.4 mm2) copper conductor attached to the bonding wire connector on the heater provided for this purpose.

All installations must comply with article 680 of the U.S. national electric code and ANSI/NFPA 70-1984.

13. Place the

SWIMCROSS

Exercise System on a firm, level surface that will not shift.

Site Requirements

e

lectrIcal

r

equIrementS

IMPORTANT: Fill the SWIMCROSS Exercise System with water before turning on the power.

Your ENDLESS POOLS SWIMCROSS Exercise System has been carefully designed to give you maximum safety against electrical shock.

Connecting the SWIMCROSS Exercise System to an improperly wired circuit will negate many of the SWIMCROSS Exercise System’s safety features. Improper wiring may also cause electrocution, risk of fire, and other risks of injuries. Please read and follow the electrical installation requirements and instructions completely!

230 VOLT PERMANENTLY

CONNECTED

ENDLESS POOLS SWIMCROSS Exercise Systems must be wired in accordance with all applicable local electrical codes. All electrical work should be done by an experienced, licensed electrician. We recommend the use of appropriate electrical conduit, fittings, and wire for all circuits.

The diagram below illustrates how to wire the SWIMCROSS

Exercise System model:

• An electrical subpanel containing a 60 Amp breaker is included with your SWIMCROSS Exercise System. We recommend that this subpanel be used to supply power to the SWIMCROSS Exercise

System.

• The subpanel requires a 60 amp, single phase, 230 volt, four wire service (two line, one neutral, one ground). The grounding conductor must not be less than #6 AWG. Refer to local codes and to NEC 250-122 (table).

• Mount the subpanel in the vicinity of the SWIMCROSS Exercise

System, but not closer than five feet away, in accordance with all local codes. (N.E.C. 680-38 to 41-A-3)

• Open SWIMCROSS Exercise System by removing the 4 screws holding the vertical T-spacer located in the center of the equipment compartment (back side of SWIMCROSS Exercise System). Slide panel towards center and remove, repeat for other panel.

• Insert power wires into SWIMCROSS Exercise System from either side towards the bottom, you will find a plastic cap attached to wall.

• Once your SWIMCROSS Exercise System has been filled with water, turn it on and test all of the circuit breakers.

IMPORTANT: If breaker immediately trips, verify that the wires are correctly connected. Breaker should be tested prior to each use. Here’s how:

1. Push the “TEST” button on each GFCI breaker, and observe it click OFF.

2. Wait 30 seconds, then push the breaker switch to the OFF (down) position (to ensure that it has completely disengaged), then push the breaker switch to the ON (up) position. If you don't wait 30 seconds, the SWIMCROSS Exercise System’s power indicator may continue to blink – try again.

If any of the GFCI breakers fails to operate in this manner, your

SWIMCROSS Exercise System may have an electrical malfunction, and you may be at risk of electrical shock. Turn off all circuits and do not use the SWIMCROSS Exercise System until the problem has been corrected by an authorized service agent.

WARNING: Removing, or bypassing any GFCI breaker will result in an unsafe SWIMCROSS Exercise System and will void the

SWIMCROSS Exercise System’s warranty.

IMPORTANT: If you ever need to move or relocate your ENDLESS POOLS SWIMCROSS Exercise System, it is essential that you understand and apply these installation requirements. Your ENDLESS POOLS SWIMCROSS Exercise System has been carefully engineered to provide maximum safety against electric shock. Remember, connecting the SWIMCROSS Exercise System to an improperly wired circuit will negate many of its safety features.

NOTE: Long wiring runs may require larger-gauge wire than stated.

L2

N

G

L1

Electrical Requirements

Page 5

EQUIPMENT COMPARTMENT

The illustrations below are to be used as a reference only (your SWIMCROSS Exercise System may look different). The equipment compartment is located behind the hydromassage seats (back of the SWIMCROSS Exercise System).

8

6

5

3

4

7

1

2

2

1. Hydromassage Jets & filter pump

2. Swim Jets Pump

3. Control Box & Heater

4. Bonding terminal

5. UVC Ozone

6. Bluetooth Music (optional)

7. Subwoofer (optional)

8. Wi-Fi (optional)

CAUTIONS

USE COPPER CONDUCTORS ONLY.

USE SUPPLY WIRES SUITABLE FOR 75°C/167°F.

DISCONNECT ALL SUPPLY CONNECTIONS BEFORE SERVICING.

CONNECT ONLY TO A CIRCUIT PROTECTED BY A CLASS A

GROUND-FAULT INTERRUPTER.

THESE SWIMCROSS EXERCISE SYSTEMS ARE INTENDED FOR

USE WITH GFCI SUBPANEL PROVIDED.

INCORRECT WIRING WILL DAMAGE CIRCUIT BOARDS.

REFER TO THE WIRING INSTRUCTIONS INCLUDED WITH THE

SUB-PANEL FOR DETAILED WIRING INSTRUCTIONS.

DOOR PANEL REMOVE & REPLACE

REMOVAL

1. Locate the vertical T-spacer in the center of the equipment compartment (back side of

SWIMCROSS Exercise System).

2. Remove the 4 screws (using a 5/16" socket) holding the T-spacer then remove the T-spacer.

3. Slide panel towards center until panel is no longer behind corner.

4. While holding panel, first pull panel up then pull bottom away from SWIMCROSS

Exercise System.

5. Lower panel to remove. Repeat for other side.

REPLACE

1. Raise panel making sure it goes behind the bar top then lower to rest on bottom frame

2. Slide panel behind corner.

3. Replace other side panel using steps 1 & 2.

4. Attach T-spacer back in place using 4 screws to complete the installation.

Page 6

Electrical Requirements

G

ettInG

S

tarted

MAIN

SWIMCROSS EXERCISE

SYSTEM FEATURES

X200 is illustrated, your SWIMCROSS Exercise System may look different.

1 ) The control panel provides a quick visual check of the SWIMCROSS Exercise System’s status and allows the user to set different functions of the SWIMCROSS Exercise System.

2) The Air Valve allows you to add air to your hydromassage jets.

3) The Water Feature Valve adjusts the amount of water that flows from the water feature (2x for

X500).

4) The Swim jets provide a strong flow of water creating a current to swim against.

5) The Large Hydromassage jets provide a unique, pulsating massage.

6) The Midsize Directional Hydromassage jets, with eyeball nozzles, deliver a direct, more focused massage.

7) The Midsize rotational Hydormassage jets, provide a rotating massage.

8) The Mini Hydromassage jets feature a direct more focused massage.

9) Pillow

10) Main Light

11) Swim Speaker (Optional)

12) Seating area Speaker (Optional)

13) Suction Screen

Getting Started

16

Page 7

11

4

1

13

14

15

18

17

10 19

3

5

6

7

9

12

8

20

2

ADDITIONAL

SWIMCROSS EXERCISE

SYSTEM FEATURES

14) Water feature (2x for X500)

15) Ozone Jet/Heater Return

16) Grab Rails

17) Filter Compartment Grill (2x for X500)

18) Points of light

19) Row Bar Anchor

20) Tether Anchor

HYDROMASSAGE JETS

LARGE HYDROMASSAGE Jets - This jet provides a unique, pulsating massage. The water flow is adjustable in that it can be turned from low to high (by rotating the jet faceplate ¼ turn).

MIDSIZE DIRECTIONAL JET - These jets allow you to redirect the jet stream by changing the position of the nozzle. The water flow is adjustable in that it can be turned from low to high (by rotating the jet faceplate ¼ turn)

MIDSIZE ROTATIONAL JET - These jets provide a rotating massage pattern. The water flow is adjustable in that it can be turned from low to high (by rotating the jet faceplate ¼ turn)

Mini JET - These jets deliver a direct, more focused massage. The water flow is adjustable in that it can be turned from low to high (by rotating the jet faceplate ¼ turn)

SWIM JETS

Swim Jet - The Swim Jet provide a powerful stream of water used to simulate a water current.

WATERFALL VALVE

Your SWIMCROSS Exercise System is equipped with a waterfall feature. It is activated by turning on the hydromassage jets (either low or high speed). The flow is regulated by turning the waterfall valve on the inside wall of the SWIMCROSS Exercise System.

AIR CONTROLS

Your SWIMCROSS Exercise System is equipped with two air valves. The air valves will add or remove air to the hydromassage jet system. Rotate valve to see which hydromassage jets are affected.

QUICK START-UP INSTRUCTIONS

BEFORE YOU FILL YOUR

SWIMCROSS

EXERCISE SYSTEM

Make sure your SWIMCROSS Exercise System has been properly installed per all local codes, this includes the location of the

SWIMCROSS Exercise System, the foundation of the SWIMCROSS

Exercise System, as well as the electrical installation of the

SWIMCROSS Exercise System. Installation instructions in the form of a

Pre-Delivery Instruction booklet can be obtained online.

DO:

• Know which water treatment system you will be using and make sure you have necessary chemicals available. Read all of the instructions that come with the system.

• Have 5-way Test Strips Available.

• Have pH/Alkalinity Up & Down available.

• Know the Hardness of your water, contact your dealer to help you with this information. See Water Quality and Maintenance for more information.

IMPORTANT: Watkins Manufacturing Corporation does not recommend that the

SWIMCROSS Exercise System be filled with

“softened” water, as this may damage the SWIMCROSS Exercise

System’s equipment.

• Purchase the Clean Screen

®

pre-filter to remove unwanted contaminants from the tap water. This is recommended, not required.

DON'T:

• Fill the SWIMCROSS Exercise System with hot water or cold water with cold water temperature below 50º F (10º C)! Tripping of the highlimit thermostat may result causing your SWIMCROSS Exercise

System to stop functioning.

Page 8

Getting Started

START-UP

Your ENDLESS POOLS SWIMCROSS Exercise System has been thoroughly tested during the manufacturing process to ensure reliability and long-term customer satisfaction. A small amount of water may have remained in the plumbing after testing and, as a result, may have spotted the SWIMCROSS Exercise System shell or the SWIMCROSS

Exercise System siding prior to delivery. Before filling the

SWIMCROSS

Exercise System, wipe the SWIMCROSS Exercise System shell clean with a soft rag. The following instructions must be read and followed exactly to ensure a successful start-up or refill.

CAUTIONS

• Do NOT fill the SWIMCROSS Exercise System with hot water, as tripping of the high-limit thermostat may result.

• DO NOT CONNECT POWER TO AN EMPTY SWIMCROSS

Exercise System. Power to the SWIMCROSS Exercise System automatically activates critical components within the SWIMCROSS

Exercise System, such as controls, heater, and other systems. If power is supplied to these components prior to the SWIMCROSS Exercise

System being filled, the components will be damaged, and this may result in a non-warranty component failure.

• DO NOT use your SWIMCROSS Exercise System after filling until all of the steps listed below are completed.

• DO NOT add chlorine if treating your SWIMCROSS Exercise

System with polyhexamethylene biguanide (Biguanide, PHMB, eg.

BaquaSpa

®

) sanitizer.

• Before filling your SWIMCROSS Exercise System for the first time, remove the equipment compartment door and check to ensure that the unions on either side of the pump(s) and heater are hand-tight and the slide valves are open.

1.

CLOSE DRAIN, remove the filter compartment grill skimmer

tray and one filter (pg. 19). Fill your SWIMCROSS Exercise

System through the filter compartment using the CleanScreen

™ pre-filter that attaches to your garden hose. The water level of your

SWIMCROSS Exercise System should be maintained at a level

6" (15 cm) below the top of the SWIMCROSS Exercise System.

Reinstall the filter, skimmer tray, and grill once the SWIMCROSS

Exercise System is filled.

IMPORTANT: Watkins Manufacturing Corporation does not

recommend that the

SWIMCROSS Exercise System be filled with

“softened” water, as this may damage the

SWIMCROSS Exercise

System’s equipment.

2.

AFTER THE SWIMCROSS EXERCISE SYSTEM HAS BEEN

FILLED with water and the equipment compartment door is secured, power must be applied to the SWIMCROSS Exercise

System.

• FIRST activate power to the subpanel from the main house panel.

• NEXT open the door of the electrical subpanel and reset the

GFCI breaker.

• FINALLY, close and secure the subpanel door.

3. TO CHECK THE OPERATION OF THE JET SYSTEM and to purge any remaining air from the heating system complete the following steps:

• Press the jets button and place all jet pumps on High.

• Once the jet system is fully operational (as indicated by strong, non-surging jets), priming of the SWIMCROSS Exercise System is complete.

Getting Started

Page 9

• To turn off the jets, press all of the jets button on the control panel to turn off the jets.

• If you do not feel a steady stream of water from your jets, refer to the instructions for priming the pump in the

SWIMCROSS

Exercise System TROUBLESHOOTING section.

4. SET THE TEMPERATURE CONTROL to the desired temperature between 59°F (15°C) and 104°F (40°C), then place the SWIMCROSS Exercise System cover on the SWIMCROSS

Exercise System and allow the water temperature to stabilize approximately 1°F (0.5°C) per hour. Make sure you secure the cover in place. Periodically check the

SWIMCROSS Exercise System water temperature. When the water temperature reaches desired temperature, proceed to the next step. The

SWIMCROSS Exercise

System temperature is pre-programmed to reach 85°F (29.5°C).

You may change the water temperature by pressing the  button on the control panel to raise the temperature, or lower temperature by pressing the ▼button.

5. USING A TEST STRIP AND APPLICABLE CHEMICALS adjust

Total Alkalinity (TA) to 80-120 ppm, Calcium Hardness (CH) to

50-150 ppm, then SWIMCROSS Exercise System water pH to between 7.2 and 7.8. These procedures are listed in the “Water

Quality and Maintenance” section.

OPERATION NOTE: Adjusting the Total Alkalinity as the first step

is important, as out-of balance TA will affect your ability to adjust the pH correctly and will prevent the sanitizer from operating effectively.

IMPORTANT: Activate all the jets (press the jets buttons and place

all jet pumps on high for 10 minutes) before adding chemicals.

Disperse the chemicals in the swim area away from the walls.

6.

SUPERCHLORINATE the SWIMCROSS Exercise System

WATER by adding 1½ teaspoons of chlorine (sodium dichlor) per

250 g allons (950 liters) of water while running the jets on high for

10 minutes. Disperse the chemicals in the swim area away from the walls.

7.

TEST THE SWIMCROSS Exercise System WATER FOR

CHLORINE RESIDUAL. If the residual is between 1 and 5 ppm on the test strips, go on to the next step. If the residual is less than 1 ppm, activate the jets on high speed for another 10 minutes and add more chlorine as needed, then retest.

WARNING: High sanitizer levels can cause discomfort to the user’s

eyes, lungs and skin. Always allow the sanitizer level to fall to the recommended range before using the

SWIMCROSS Exercise

System.

8. RECHECK the Total Alkalinity (TA) 80-120 ppm, Calcium Hardness

(CH) 50-150 ppm, and the pH must be between 7.2 and 7.8.

The SWIMCROSS Exercise System is ready for use when the

SWIMCROSS Exercise System water has circulated and the bromine level remains between 1 and 2 ppm or chlorine level remains between 1 and 5 ppm.

OPERATION NOTE: For proper water circulation during the tenminute cycle place the air control switches in OFF position.

o

peratInG

I

nStructIonS

CONTROL PANEL

The control panel provides a bright, full color display, and intuitive user experience, while its screen’s high resolution brings SWIMCROSS

Exercise System user interfaces to a new level. Loaded with a large amount of memory and a powerful on-board processor creating seamless graphic interface that

SWIMCROSS Exercise System users have been waiting for.

CONTROL PANEL FUNCTIONS

When the screen is off, press any button to turn the control panel screen on and display the home screen. After 30 minutes of inactivity the screen will shut off.

The function description of the buttons below will only work from the

Home screen. Once the control panel is placed in a submenu the selection lights next to the buttons will light up to indicate which buttons may be selected for a specific screen function.

Hydromassage Jets Selection Button

Settings

Top

Swim Jets

Audio

Up/

Temperature

All Off/

Memory On

Bottom

Swim Jets Selection Lights Lights

Down/

Temperature

SETTINGS

One press of the (Settings button) from the home page gives you access to a menu to manage the settings of your SWIMCROSS

Exercise System where you will find:

• Water care

• Audio (optional)

• Maintenance

• Date and time

• Keypad Settings

• Wi-Fi (optional)

• Electrical configuration

• Factory reset

• About

Use the or buttons to move up and down in the list. To select an option, press the lit button beside the desired highlighted option.

IMPORTANT: At any point you can press the (Settings button) to return to the home screen or top left button (hydromassage jets) to go back.

WATER CARE

The Water Care section will help you set up your ideal filtration and heating settings. Choose from Away from Home,

Beginner, Energy Savings, Super Energy

Savings, and Weekender, depending on your needs.

Use (middle left) button to choose your setting. A green check mark will appear on the selected icon to confirm.

When in Economy mode, the heating set point will be reduced by 20°F

(11°C), which means that the heating system will not come on during the set time unless the temperature falls 20°F (11°C) below the set temperature.

The filtration schedule shown on the screen will apply to the main filtration pump (hydromassage jets).

WATER CARE MODES

Away from home:

In this mode the System will always be in economy mode; the set point will be reduced by 20°F.

Beginner:

The System will never be in economy mode and will be filtering according to the pack's low level configuration.

Energy Savings:

The System will be in economy mode during the peak hours of the day and resume normal mode on the weekend*.

Super Energy:

The System will always be in economy mode during peak hours, every day of the week*.

Weekender:

The System will be in economy mode from Monday to Friday, and will run normally on the weekend*.

*Filtration will be reduced when the economy mode is active.

MODIFYING SCHEDULES

To modify a Water Care category, use the (middle right) lit button, to open the selected Water Care menu.

The menu screen is divided into two settings, Economy and Filter cycle with

Economy being first. Set or change the

Day, Start and Stop time if desired to keep the heater off (Economy mode).

Scroll down to set or change the Filter cycle Day, Start and Duration.

You can add schedules by scrolling down to Add, and selecting by using the (middle left) lit button.

To delete a schedule, press

(top right) lit button.

You can modify the programmed schedules by selecting one

(middle left) lit button and adjusting the schedule using the or buttons. Press (middle left) lit button to move between parameters.

Page 10

Operating Instructions

You have several possibilities for the schedule (Mon-Fri, weekend, every day, or single days). The schedules will be repeated every week. The time and duration are set in 30 minute increments. Once you have set the schedule, use

(top left) lit button to go back.

Ensure that you have selected the desired Water Care option in the main

Water Care menu.

MAINTENANCE

From the Settings page you can access the Maintenance menu, which gives you access to the following options:

• Maintenance reminders

• Standby

• Error log

Use the or buttons to make a selection, and (middle left) lit button to select.

MAINTENANCE REMINDERS

The control panel will remind you of maintenance required on your

SWIMCROSS Exercise System, like rinsing or cleaning the filter. Each task has its own duration, based on normal use.

The Maintenance reminders menu allows you to verify the time left before maintenance is required, as well as to reset the time once a task is completed.

Use the or buttons to move through the list.

To reset a task select it by pressing the (middle left) lit button, then confirm by pressing the lit button next to confirm when prompted. Once you have confirmed the task will be reset.

STANDBY

The Standby mode allows you to service your System. Pumps will stop for 30 minutes, and automatically restart after this time. Press

(middle left) lit button to activate

Standby mode.

Once Standby mode has been activated a screen will appear to show that pumps are stopped. The normal page will return at the end of maintenance.

Press on the button next to cancel to leave Standby mode and restart the

SWIMCROSS Exercise System.

ERROR LOG

In this section you can see errors that have been archived by the system. Use the or buttons to move through the list. Errors are archived chronologically, from most recent to oldest (top to bottom).

Operating Instructions

The Error log page shows the error code, the date of the error, and the time. To see more details on an error select it with (middle left) lit button. A screen will appear with more information on the selected error.

For more information, see the Error messages section. To clear the Error log page press (top right) lit button and confirm when prompted. The page will be cleared.

DATE AND TIME

Here you can adjust the time format, change the year, date, and time.

Use the or buttons to choose the setting that you want to adjust, and select it by pressing

(middle left) lit button.

Use the or buttons to change the parameters, and (middle left) lit button to move between parameters. Press (top left) lit button to take you back to the main

Settings menu.

KEYPAD SETTINGS

In this section, you can change the temperature unit, language, display orientation, rim around the control panel light color, and lock the control panel.

Use the or buttons to choose the setting that you want to adjust. Select it by pressing the

(middle left) lit button then use the or buttons again to change the setting.

When you change the display orientation, the contextual options and or buttons adjust to the chosen orientation. The Audio and Setting buttons remain unchanged, as well as the jets and lights buttons in the home page.

Security settings allow you a Partial (Temperature) lock or Full (entire control panel) lock. Select Security screen by pressing the (middle left) lit button then use the or buttons to change to Full, Partial or

Unlock. Press (top left) lit button to display an information screen telling you to press and hold button for 5 seconds to lock.

To unlock Full, press and hold button for 5 seconds.

ELECTRICAL CONFIGURATION

Please do not make changes in this section!

ABOUT

Page 11

This section shows information about the control panel software number, and the revision numbers of the different components of your system.

WI-FI

(OPTIONAL)

This menu allows you to connect your in.touch module to a Wi-Fi network or to change its network.

This menu is only visible when the in.touch module is installed.

To connect your in.touch module to a wireless network, use the or buttons to go to the Wi-Fi option in the Settings menu and (middle left) lit button to select it.

After a few seconds the available networks will appear on the screen, as well as their signal strength.

Use the or buttons to move through the list. Select your network by pressing the middle left button (top swim jets).

If the Wi-Fi network is password protected enter it when prompted.

• Use the or buttons to choose your letters.

• Use (lower right) lit button to move the curser forward.

• Use (top right) lit button to change the type of character.

(uppercase, lowercase, number, symbol).

• Use (lower left) lit button to backspace.

• Use (middle left) lit button to confirm.

If no password is required the in.touch will connect automatically.

Once the in.touch module is connected to a Wi-Fi network a green check mark will appear in the Wi-Fi menu, and the network name will appear in the

Settings menu.

IN.STREAM 2 FUNCTIONS

Press the button in the home screen to access your audio system.

If you are using a device with Bluetooth technology, it must be connected for functions to work.

Please note that the Play/Pause and Change Track functions apply to devices using Bluetooth technology only, and will NOT work when AUX is selected as the source.

TURNING POWER ON/OFF

Press the (top right) lit button to start the audio on or off process.

SELECTING THE SOURCE

Press the (top left) lit button to select a source using

Bluetooth wireless technology or

AUX (aux is not available at time of publication). Selection will be indicated below In.stream 2.

PAIRING BLUETOOTH

Audio Power must be on. Go to the Bluetooth settings on your device and find in.stream 2 and press to connect. Enter pin 5555 and press pair to sync your device.

NOTE: Only one device at a time can be synced.

PLAY/PAUSE AUDIO

Press the Play/Pause (middle right) lit button to start or pause the audio. Press (middle left) lit button to mute or enable sound.

ADJUSTING THE VOLUME

Press the or buttons to increase or decrease the volume illustrated by the slider bar.

CHANGING TRACKS

Use the Last Track and Next Track (lower left) lit button or

(lower right) lit button to change tracks.

AUDIO IN.STREAM 2 (OPTIONAL)

If your SWIMCROSS Exercise System has the optional in.stream 2

Bluetooth w/subwoofer system the following screens and functions will be available on the control panel:

AUDIO

The control panel is used with the in.stream 2 audio system. The Audio screen in the Settings menu gives you the option to disconnect your

Bluetooth enabled device, adjust the Fader, Balance or Sub Woofer.

Use the or buttons to scroll to desired option, press

(middle left) lit button to select the function. Press the or buttons to change parameters.

Press (top left) lit button to take you back to the main Settings menu.

TEMPERATURE CONTROL

The set temperature range is from 59°F to 104°F (15°C to 40°C). (The water temperature of any SWIMCROSS Exercise System may rise or lower slightly depending on the current use and condition of your

SWIMCROSS Exercise System and on outside temperatures.)

The set temperature of the SWIMCROSS Exercise System water will automatically be 85°F (29.5°C) the first time power is applied. This is the setting programmed at the factory. After the SWIMCROSS Exercise

System has been set up and used, the last temperature value set by the user will be stored in memory. If power is disconnected from the

SWIMCROSS Exercise System, it will automatically revert to the last set temperature when power is reapplied.

To display the set temperature of the SWIMCROSS Exercise System:

Press the or buttons on the control panel in the home screen.

To increase the set temperature of the Exercise System:

Page 12

Press the button in the home screen. The set point will appear in blue. After 3 seconds without any change to the set temperature value, the current water temperature will reappear in white.

To decrease the set temperature of the SWIMCROSS Exercise System:

Press the button in the home screen. The set point will appear in blue.

After 3 seconds without any change to the set temperature value, the current water temperature will reappear in white.

Operating Instructions

JETS CONTROL

When pressed, the three buttons on the left of the screen will activate the jets when in the home screen. If left running the low or high speed pumps will automatically turn off after 1 hour.

HYDROMASSAGE JETS

Turn the hydromassage jet pump On to activate all of the hydromassage jets in the seated area as well as the waterfall if the waterfall valve is open. This pump has a low speed and high speed mode.

This jet pump will automatically turn on in low speed when the system is calling for heat or the filtration cycle.

Press jet button to activate the hydromassage jets in low speed, you will see the jet 1 icon on the screen rotate slowly.

Press jet button a second time to place the hydromassage jets in a high speed, you will see the jet 1 icon on the screen rotate faster.

Press jet button a third time to shut the hydromassage jets off.

SWIM JETS - TOP 3 JETS

The SWIMCROSS Exercise System uses a 2.5 Horsepower two speed pump to power the top 3 swim jets.

Press jet button to activate the top row of jets (swim area) in low speed, you will see the jet 2 icon on the screen rotate slowly.

Press jet button a second time to activate the top row of jets in high speed, you will see the jet 2 icon on the screen rotate faster.

Press jet button a third time to shut the top row of jets off.

SWIM JETS - BOTTOM 2 JETS

The SWIMCROSS Exercise System uses a 2.5 Horsepower single speed pump to power the bottom 2 swim jets.

Press jet button to turn the bottom row of jets in the swim area on, you will see the jet 3 icon on the screen rotate fast.

Press jet button a second time to shut the bottom row of jets off.

SWIM JETS SPEED OPTIONS

There are 5 different Swim Jet options that can be created as follows:

Speed Option

1

2

3

4

5

Top 3 Jets

High

Low

Off

High

Low

Bottom 2 Jets

On

On

On

Off

Off

LIGHT CONTROL

All SWIMCROSS Exercise Systems are equipped with a lighting system.

This system includes a main light facing the swim area as well as points of lights located throughout the SWIMCROSS Exercise System.

Press the (lower right) button (when in the home screen) to activate all lights.

Press the (lower right) button a second time to shut all lights off, when turning back on after several seconds the same light mode will appear.

Every time the light is turned off and on quickly a new light mode will appear.

The sequence is as follows: White,

Aqua, Magenta, Azure, Amber,

Emerald, Ruby, color wheel with abrupt color changes, slow full color wheel and fast full color wheel.

NOTE: If left on, the light will automatically turn off after 4 hours of operation.

FILTER CYCLES

When your SWIMCROSS Exercise System is first powered up, the default filter cycle is set to start at 12:00 pm and will run for 5 hours each day using the Beginner Water Care mode. Unless you set the time using the control panel (see Date & Time under Settings) the SWIMCROSS

Exercise System filter cycle will start at power up and run for 5 hours and repeat every 24 hours.

We recommend setting your date and time first, then going to the Water

Care section and making any desired changes for days, start times and length of time in the desired Water Care Mode.

The filter cycle will activate the hydromassage jets on low speed for the entire cycle that has been programmed.

NOTE: Power interruption of the

SWIMCROSS Exercise System will not change the filter cycle settings when power is regained.

ALL OFF /

MEMORY ON

Press the (middle right) button when in the home screen to turn the lights and any jets that are on OFF. It will not turn the music system off.

If you press this button again before pressing the light or jets button it will bring up the last settings before shutting off.

NOTE: The color of the lights will however advance to the next sequence.

WI-FI IN.TOUCH (OPTIONAL)

If your SWIMCROSS Exercise System is equipped with the Wi-Fi in.touch module you will be able to use the internet or your home Wi-Fi network to control your SWIMCROSS Exercise System by downloading an App to your favorite devices.

See Wi-Fi in the Settings section to connect your SWIMCROSS

Exercise System to your home Wi-Fi network.

For instruction on how to download the App to your device search "gecko in.touch" in your App store. For more instructions go online to the in.touch setup guide: http://www.geckoalliance.com/Documents/intouch_ setupguide_d_en.pdf

Operating Instructions

Page 13

W

ater

q

ualIty and

m

aIntenance

BASIC INFORMATION

It’s important to have clean water. Water maintenance is one of the least understood, yet most important areas of SWIMCROSS Exercise System ownership. Your dealer can guide you through the process of achieving and maintaining balanced water in your SWIMCROSS Exercise System, given your local conditions.

IMPORTANT: Water Terminology can be found at the end of this section.

• Always read & refer to the owner's manual for complete information.

• Test your water with a test strip once a week, or each time the

SWIMCROSS Exercise System is used.

• Add chemicals in frequent, small amounts to prevent overdosing the

SWIMCROSS Exercise System.

• Use the SWIMCROSS Exercise System only when the chlorine level is between 1-5 ppm or manually add chlorine as needed.

• It is the SWIMCROSS Exercise System owner's responsibility to prevent over or under chlorination.

IMPORTANT: It is recommended at a minimum to change 50% of your water every year; however, it is dependent on the amount of usage.

Check with your ENDLESS POOLS dealer to determine if water in your region has unique qualities - such as high metal or mineral content - that should be addressed.

WATER QUALITY CHART

PARAMETER pH

ALKALINITY

HARDNESS

CHLORINE

TARGET

7.4

100 ppm

100 ppm

3 ppm

MIN - "OK" RANGE - MAX

7.2

7.8

80 ppm

50 ppm

1 ppm

120 ppm

150 ppm

5 ppm

Maintaining the water quality and the cleanliness of the filters in your

SWIMCROSS Exercise System is your responsibility. Keeping the

SWIMCROSS Exercise System water balanced prolongs the life of the components and will make the water more comfortable. Your program will depend on your water’s mineral content, how often you use your

SWIMCROSS Exercise System, and how many people use it. Watkins

Manufacturing Corporation has developed several water care systems and products to simplify water care which are available from authorized

ENDLESS POOLS dealers.

CHEMICAL SAFETY

When using chemicals, read the labels carefully and follow directions precisely. Though chemicals protect you and your SWIMCROSS

Exercise System when used correctly, they can be hazardous in concentrated form. Always observe the following guidelines:

• Allow only a responsible person to handle

SWIMCROSS Exercise

System chemicals. Keep them out of the reach of children.

• Accurately measure the exact quantities specified, never more. Do not overdose your SWIMCROSS Exercise System.

Page 14

• Handle all containers with care. Store in a cool, dry, well ventilated place.

• Always keep chemical containers closed when not in use. Replace caps on their proper containers.

• Don't inhale fumes, or allow chemicals to come in contact with your eyes, nose, or mouth. Wash your hands immediately after use.

• Follow the emergency advice on the product label in case of accidental contact, or if the chemical is swallowed. Call a doctor or the local

Poison Control Center. If a doctor is needed, take the product container along with you so that the substance can be identified.

• Don't let chemicals get on surrounding surfaces or landscaping. Don't use a vacuum cleaner to clean up chemical spills.

• Never smoke around chemicals. Some fumes can be highly flammable.

• Don't store any chemicals in the SWIMCROSS Exercise System equipment compartment.

HOW TO ADD CHEMICALS

TO THE WATER

IMPORTANT: All SWIMCROSS Exercise System water chemicals, must always be dispersed into the swim area while all jet pumps are running on high, and must run for a minimum of ten minutes.

TO ADMINISTER

SWIMCROSS EXERCISE

SYSTEM WATER CHEMICALS:

1. Fold back the cover.

2. Turn all 3 jets systems ON, run for 10 minutes and turn OFF.

3. Carefully measure the recommended amount of chemical and disperse into swim area while jets are on. Use care not to splash chemicals on your hands, in your eyes, on the SWIMCROSS

Exercise System sheet surface, or on the siding.

Risk of Drowning: Never leave an open SWIMCROSS Exercise

System unattended!

WARNING: High sanitizer levels can cause discomfort to the user’s eyes, lungs and skin. Always allow the sanitizer level to fall to the recommended range before using the

SWIMCROSS Exercise System.

IMPORTANT “SUPER CHLORINATION/NON-CHLORINE SHOCK

TREATMENT” NOTE: After administering a super chlorination treatment or non-chlorine shock to your SWIMCROSS Exercise System, leave the cover open for a minimum of 20 minutes to allow the oxidizer gas to vent. A high concentration of trapped oxidizer gas which may exist as a result of the shock treatment (not daily sanitation) may eventually cause discoloration or vinyl degradation to the bottom of the cover.

FUNDAMENTALS OF

WATER MAINTENANCE

• Testing: Test the water weekly or each time the SWIMCROSS

Exercise System is used with convenient test strips or more accurate liquid/tablet reagent test kit per instructions. Critical parameters: sanitizer level, pH, Calcium Hardness (CH), and Total Alkalinity (TA).

Store test equipment in a dark, cool, dry place to maintain potency.

Water Quality and Maintenance

• Chemical Balance/pH Control: It is important to adjust the primary water parameters (Total Alkalinity, Calcium hardness, pH) into the recommended ranges so that they are stabilized or balanced. Balance the water chemistry every time you fill the SWIMCROSS Exercise

System with new water and then during the life of that body of water.

Keeping the water in balance prevents damage by holding the pH in a safe range and preventing calcium scale formation on SWIMCROSS

Exercise System equipment. A low pH can damage metal components whereas a high pH can cause high levels of calcium to form scale. Your dealer should provide a detailed water chemistry orientation soon after your new SWIMCROSS Exercise System is filled for the very first time.

• The following three water

ALKALINE

WATER

8.2

ADD pH

DECREASER components must be kept in balance to avoid damage to the SWIMCROSS Exercise

System. Do balance these components in the order they are listed here as each will help you balance the next using a minimum amount of chemicals.

(SCALING

ZONE)

COMFORT

ZONE

7.8

7.6

7.4

7.2

TO LOWER pH

IDEAL

1. Calcium Hardness (CH)

– CH is the measure of the amount of dissolved calcium in the water.

ACIDIC

WATER

(CORROSIVE

ZONE)

6.8

pH

ADD pH

INCREASER

TO RAISE pH

Low levels can make the water corrosive and high levels cause scale formation on

SWIMCROSS Exercise System components.

The recommended CH reading is between

50 - 150 ppm. If the CH level is too high, lower it with the calcium remover per instructions. Once in balance, the CH reading normally remains stable until more water is added. Great care must be taken when filling the SWIMCROSS Exercise System from a water softener to ensure that the calcium remains in balance and avoid damage to the SWIMCROSS Exercise System.

2. Total Alkalinity (TA) - TA is a measure of the water’s ability to resist changes of pH or buffer capacity. A low TA allows the pH to fluctuate easily. The recommended TA reading is between

80 - 120

ppm. To raise the TA, use pH/Alkalinity Up (sodium hydrogen carbonate). To lower the TA, use pH/Alkalinity Down (sodium bisulfate). We recommend you check the TA reading once per month. Raising/lowering the TA may cause the pH readings to fluctuate widely. Ignore the pH readings on the test strip while you are balancing the TA.

3. pH - The pH is the measure of the acidity and alkalinity.

Maintaining the proper pH level will optimize the effectiveness of the sanitizer, preventing damage to the SWIMCROSS Exercise

System and physical discomfort for SWIMCROSS Exercise System users. A low pH dissipates sanitizer, causes corrosion, and irritates SWIMCROSS Exercise System users. A high pH level will neutralize sanitizer, promote scaling and cloud water. The recommended pH reading is between 7.2 - 7.8. To lower the pH level, use pH/Alkalinity Down (sodium bisulfate). To raise the pH level, use pH/Alkalinity Up (sodium carbonate).

• Water Conditioners: SWIMCROSS Exercise System fill water varies from location to location and user to user, therefore it is important to consult with your dealer for an appropriate program. a. CLEAN SCREEN pre-filter –The CLEAN SCREEN pre-flter should be used at every fill and top-off to remove contaminants from the fill water, especially iron, copper, and manganese. Many water sources, including well water, contain high concentrations of minerals that can cause staining of the shell and plastics.

Water Quality and Maintenance

Page 15

b. Stain and Scale control – For water high in calcium and minerals, it may be necessary to use an anti-scalant like Stain and Scale control. As water evaporates from your SWIMCROSS Exercise

System and new water is added, the amount of dissolved minerals like calcium, copper, iron, and manganese will increase. (Minimize evaporation by keeping the cover on the SWIMCROSS Exercise

System whenever possible.) High iron or copper content in the water may produce green or brown stains on the SWIMCROSS

Exercise System.

c. Foam Inhibitors - Soap is introduced into the SWIMCROSS

Exercise System water from users’ bodies and swimming apparel and can cause the SWIMCROSS Exercise System water to foam when the jets are used. Low levels of calcium hardness (soft water) can increase foaming. Although ozone can oxidize soap residual, it may become necessary to add Foam Inhibitors to suppress the foam. Excessive soap in the water may require a water change to resolve.

• Oxidizers: Ozone and Monopersulfate (MPS) are oxidizers used to prevent the buildup of contaminants, maximize sanitizer efficiency, minimize combined chlorine, and improve water clarity. They are to be used in conjunction with EPA registered sanitizers. The UVC

Ozone system combines the Corona Discharge generator and a UVC lamp. The UVC lamp kills and damages bacteria DNA on contact providing a maximum water sanitation solution. Chlorine-Free Oxidizer,

Monopersulfate (MPS) is a granular oxidizing chemical.

• Sanitizers: Maintaining the recommended residual level of an EPA registered sanitizer at all times will decrease the occurrence of unsafe bacteria and viruses in your SWIMCROSS Exercise System water.

The recommended Free Available Chlorine (FAC), the amount of available chlorine sanitizer, is 1.0-5.0 ppm. A low FAC can allow bacteria and viruses to grow rapidly in the warm water, and a high

FAC can cause discomfort to the user’s eyes, lungs, and skin. Each sanitizer carries its own instructions regarding how much to use and when to add it to the SWIMCROSS Exercise System water. Consult your dealer for their recommendations and instructions on proper sanitizing of the SWIMCROSS Exercise System.

Watkins recommends the following sanitizer:

• Sodium Dichloro-s-Triazinetrione (sodium dichlor or chlorine)

• Biguanide

• Liquid sodium hypochlorite

WARNING: DO NOT use tri-chlor chlorine, bromo-chloro-dimethylhydantoin (BCDMH), or any type of compressed bromine or chlorine, acid or any type of sanitizer which is not recommended by Watkins

Manufacturing Corporation.

THE

ENDLESS POOLS

WATER

MAINTENANCE PROGRAM

FILLING THE SWIMCROSS EXERCISE

SYSTEM WITH WATER

Use the CLEAN SCREEN pre-filter to remove unwanted contaminants such as rust, dirt, detergents, and algae from the fill water. Dissolved metals, copper, iron, and manganese are also removed. Instructions are included with the CLEAN SCREEN pre-filter. Always fill the

SWIMCROSS Exercise System through the filter compartment. Do not fill your SWIMCROSS Exercise System using water from a swimming pool as pool chemicals are very different from those used in a SWIMCROSS Exercise System and can damage your SWIMCROSS

Exercise System. or evening, additional sanitizer will be needed.

Required: a. One Silver Ion cartridge per 500 gallons.

b. Silver Ion cartridges to be placed inside filter skimmer tray

(maximum of 2 per tray).

c. Weekly Super Chlorinate/Shock the SWIMCROSS Exercise

System to reactivate the silver ion cartridge, allow the release of silver ions, and quickly destroy any remaining contaminants.

Without this weekly shock treatment, the silver ion cartridge may stop releasing silver ions into the water.

IMPORTANT: Use only Dichlor sanitizer. Silver is not compatible with bromine and biguanides. Don't use a water clarifier. Clarifiers will cause the water to become cloudy.

ADDING CHEMICALS TO THE WATER

All SWIMCROSS Exercise System water chemicals, must always be dispersed directly into the swim area while all jet pumps are running in the high speed mode, and it must run for a minimum of ten minutes with the covers off.

BUILDING A SANITIZER ROUTINE

During the first month of ownership, measure the sanitizer residual daily in order to establish a baseline of sanitizer needed vs.

SWIMCROSS

Exercise System usage. Sanitizer needed is the amount of Free

Available Chlorine needed to accommodate the number of users and their combined usage time. For example, two SWIMCROSS Exercise

System users for twenty minutes every day creates regular demand on the sanitizer that is used to determine how much sanitizer to add in order to maintain the proper residual. If the usage pattern increases dramatically with invited guests, the amount and frequency of sanitizer required will also increase.

MANUAL CHLORINE (SODIUM DICHLOR)

Watkins Manufacturing Corporation recommends the use of

Concentrated Chlorinating Granules (sodium dichlor) for sanitizing the water. Sodium dichlor is preferred because it is totally soluble, dissolves quickly, and is nearly pH neutral. The recommended Free

Available Chlorine (FAC), the amount of available chlorine sanitize the

SWIMCROSS Exercise System, 1.0-5.0 ppm.

If the FAC is too low: Increase the FAC by adding granulated sodium dichlor.

If the FAC is too high: Allow time to pass and the FAC level will naturally drop over time.

If the SWIMCROSS Exercise System smells of chlorine: super chlorinate or shock the SWIMCROSS Exercise System FAC chlorine does not have an odor whereas combined spent chlorine (chloramines) has a strong chlorine odor that can be eliminated by shocking the water.

IMPORTANT: There are several forms of stabilized chlorine available for use in SWIMCROSS Exercise Systems and swimming pools.

It is extremely important to choose one specifically designed for

SWIMCROSS Exercise Systems. Use of an incorrect product such as tri-chlor which has a very low pH (2.6) and dissolves too quickly in hot water, results in extremely high levels of chlorine that WILL cause damage to your SWIMCROSS Exercise System. Use of a liquid or compressed bromine/chlorine or unapproved sanitizer WILL damage your SWIMCROSS Exercise System and is specifically not covered under the terms of the limited warranty.

PERFORMING SUPER CHLORINATION/

NON-CHLORINE SHOCK TREATMENT

A weekly or monthly super chlorination (1.5 tsp dichlor/250 gal) or shock

(4tbs mps/250 gal) may be required of your chosen sanitation program.

Increasing chlorine to 5 ppm for 24-48 hours removes excess waste and chloramines from the water. Sodium dichlor is 6x stronger than MPS and may be more appropriate for those users that experience heavy bather load conditions. Operate all jets and leave the cover open for a minimum of 20 minutes to allow the oxidizer gas to vent to prevent damage and discoloration to the cover and pillows after administering a super chlorination or shock to your SWIMCROSS Exercise System.

This type of damage is considered chemical abuse and is not covered under the terms of the limited warranty.

IMPORTANT: Always allow the Free Available Chlorine to fall below 5 ppm before using your SWIMCROSS Exercise System.

DANGER: Never leave an open SWIMCROSS Exercise System unattended, especially if there are children present!

OZONE PLUS UV-C MAINTENANCE

If the water in your

SWIMCROSS Exercise System lacks the clarity you're used to, you find your chemicals increasingly out of balance and your water simply will not be sanitized like it should be then you should ask your technician to test your Ozone Generator and check you UV-C lamp which should be replaced after two years.

USING SILVER ION

Silver ions are introduced into the water via erosion of silver infused beads which inhibits bacteria growth. When combined with MPS, or chlorine, waste is oxidized and removed from the water. It is important to follow the recommended application and maintenance programs outlined for the product’s use. If the SWIMCROSS Exercise System is being used over an extended period of time, such as a whole afternoon

Page 16

DANGER: Corrosive condensation may collect in dips or loops in the tubing. DO NOT DRAIN IT. Have an Ozone Technician remove the acidic liquid.

Water chemistry damage is not covered by the warranty. The chemical levels and water quality in the

SWIMCROSS Exercise System are under your direct control. With proper basic care, the SWIMCROSS Exercise

System will provide many years of water relaxation. If you are unsure about any chemical or its usage in the SWIMCROSS Exercise System, contact your Authorized Dealer, or Watkins Manufacturing Corporation.

Water Quality and Maintenance

DO:

• Disperse all chemicals slowly into the swim area with the jet pumps operating for ten minutes.

• Use special care if using baking soda to clean either the interior or exterior plastic surfaces.

IMPORTANT: Watkins Manufacturing Corporation DOES NOT recommend the use of any floating chemical dispenser. Damage to the SWIMCROSS Exercise System shell or components caused by a floating chemical dispenser is specifically not covered under the terms of the limited warranty. Floating dispensers can become trapped in one area and cause an over-sanitization or release large chunks of sanitizer that very quickly chemically burn the shell and cover.

DON'T:

• Use compressed sanitizers.

• Use a floater type sanitization system as a low or no maintenance solution to your SWIMCROSS Exercise System maintenance program.

• Use a sanitizer which is not designed for SWIMCROSS Exercise

Systems.

• Broadcast or sprinkle the chemicals onto the water surface without the swim jets running during chemical additions and any additional

10 minutes after dose. This method may cause chemically-induced

SWIMCROSS Exercise System surface blistering (chemical abuse).

VACATION WATER CARE

INSTRUCTIONS

If you plan to be away from home, follow these instructions to ensure that the water quality of your SWIMCROSS Exercise System is maintained:

SHORT TIME PERIODS (3-5 DAYS):

1. Adjust the pH by following the instructions outlined in the Water Quality and Maintenance section.

2. Sanitize the water by following the shock procedures also listed in the

Water Quality and Maintenance section.

3. Lock your cover in place using the coverlocks.

4. Set Water Care Mode to Away from Home (pg.12).

5. Upon your return, sanitize the water by following the shock procedures, and balance the pH.

LONG TIME PERIODS (5-14 DAYS):

Prior to leaving:

1. At least one day before you leave, set Water Care Mode to Away.

IMPORTANT: SWIMCROSS Exercise System water oxidizers such as sodium dichlor (chlorine) maintain their level of effectiveness substantially longer in cool water 59°F

(15°C)

than in hot water 101°F to

104°F (38°C - 40°C).

2. Adjust the pH as required. Sanitize the water by following the shock procedures.

Upon your return:

3. Sanitize the water by following the shock procedures. Return the set temperature to its original setting. The SWIMCROSS Exercise System water will be safe for you to use once the Free Available Chlorine residual level has dropped below 5.0 ppm.

IMPORTANT:

If you will not be using your SWIMCROSS Exercise

System for an extended period of time (in excess of 14 days) and an outside maintenance service (or neighbor) is not available to assist with the water maintenance, draining or winterizing of the SWIMCROSS

Exercise System is recommended.

SUPPLEMENTAL WATER MAINTENANCE

Proper water sanitation and mineral balance (pH control) are absolutely essential for a complete SWIMCROSS Exercise System water maintenance program. Here are two other popular water additives that are optional:

Mineral Deposit Inhibitors

As water evaporates from your SWIMCROSS Exercise System and new water is added, the amount of dissolved minerals will increase. (Minimize evaporation by keeping the cover on the SWIMCROSS Exercise

System whenever possible.) The SWIMCROSS Exercise System water may eventually become “hard” (Calcium Hardness too high) enough to damage the heater by calcifying its surface. Proper pH control can minimize this.

Occasionally, high iron or copper content in the water may produce green or brown stains on the

SWIMCROSS Exercise System. A stain and scale inhibitor may help to reduce these metals.

IMPORTANT: Well water may contain high concentrations of minerals.

The use of a low water volume, extra-fine pore water filter (in-line prefilter such as the CLEAN SCREEN pre-filter) will help to remove many of the larger particles during the filling of the SWIMCROSS Exercise

System. In-line pre-filters can be purchased at your local

ENDLESS

POOLS dealer.

Foam Inhibitors

SWIMCROSS Exercise System water requires changing due to the buildup of soap in the water. Typically, soap will cause the

SWIMCROSS

Exercise System water to foam when the jets are used. Soap is introduced into the

SWIMCROSS Exercise System water from two sources: users’ bodies, which retain a soap residual after showering, and swimming apparel, which retains soap after washing.

Foam inhibitors can suppress foam, but cannot remove soap from the water. Soap is very difficult to remove from the water because soap is not oxidized by any chemical added to the

SWIMCROSS Exercise

System. Only ozone can oxidize soap. Eventually the soap build-up in the water will be concentrated, resulting in an unclean feeling on the bather’s skin, which is impossible to remedy. When this occurs, it’s time to drain and refill the

SWIMCROSS Exercise System.

Water Quality and Maintenance

Page 17

GLOSSARY

The following chemical terms are used in this Water Quality and

Maintenance section. Understanding their meaning will help you to better understand the water maintenance process.

Bromamines: Compounds formed when bromine combines with nitrogen from body oils, urine, perspiration, etc. Unlike chloramines, bromamines have no pungent odor, and are effective sanitizers.

Bromine: A halogen sanitizer (in the same chemical family as chlorine).

Bromine is commonly used in stick, tablet, or granular form however, stick and tablet form should NOT be used.

Calcium Hardness: The amount of dissolved calcium in the

SWIMCROSS Exercise System water. This should be approximately 50

-150 ppm. High levels of calcium can cause cloudy water and scaling.

Low levels can cause harm to the SWIMCROSS Exercise System equipment.

Chloramines: Compounds formed when chlorine combines with nitrogen from body oils, urine, perspiration, etc. Chloramines can cause eye irritation as well as having a strong odor. Unlike bromamines, chloramines are weaker, slower sanitizers.

Chlorine: An efficient sanitizing chemical for SWIMCROSS Exercise

Systems. Watkins Manufacturing Corporation recommends the use of sodium dichlor-type granulated chlorine. This type is preferred because it is totally soluble and nearly pH neutral.

Chlorine (or Bromine) Residual: The amount of chlorine or bromine remaining after chlorine or bromine demand has been satisfied. The residual is, therefore, the amount of sanitizer which is chemically available to kill bacteria, viruses and algae.

Corrosion: The gradual wearing away of metal and plastic

SWIMCROSS Exercise System parts, usually caused by chemical action. Generally, corrosion is caused by low pH or by water with levels of

TA, CH, pH or sanitizer which are outside the recommended ranges.

Halogen: Any one of these five elements: fluorine, chlorine, bromine, iodine, and astatine.

MPS: Monopersulfate is a non-chlorine oxidizer.

Nitric Acid: The formulation of nitric acid, a highly corrosive chemical, is a byproduct of the ozone generating process. Nitric acid is produced in very small quantities and is readily dissolved in the water stream with ozone.

Oxidizer: The use of an oxidizing chemical is to prevent the buildup of contaminants, maximize sanitizer efficiency, minimize combined chlorine and improve water clarity. See MPS and Ozone.

Ozone: Ozone is a powerful oxidizing agent which is produced in nature and artificially by man. Ozone forms no byproducts, oxidizes chloramines, and will not alter the water’s pH.

pH: The measure of the SWIMCROSS Exercise System water’s acidity and alkalinity. The recommended pH for the SWIMCROSS

Exercise System water is 7.2 to 7.8. Below 7.0 (considered neutral), the

SWIMCROSS Exercise System water is too acidic and can damage the heating system. Above 7.8, the water is too alkaline and can result in cloudy water, and scale formation on the shell and heater.

ppm: The abbreviation of “parts per million”, the standard measurement of chemical concentration in water. Identical to mg/l (milligrams per liter).

Reagent: A chemical material in liquid, powder, or tablet form for use in chemical testing.

Sanitizer: Sanitizers are added and maintained at recommended residuals to protect bathers against pathogenic organisms which can cause disease and infection in SWIMCROSS Exercise System water.

Scale: Rough calcium-bearing deposits that can coat SWIMCROSS

Exercise System surfaces, heaters, plumbing lines, and clog filters.

Generally, scaling is caused by mineral content combined with high pH.

Additionally, scale forms more readily at higher water temperatures.

Super-Chlorination: Also known as “shock treatment.” Super-

Chlorination is a process of adding significant doses of a quick dissolving sanitizer (“dichlor” is recommended) to oxidize non-filterable organic waste and to remove chloramines and bromamines.

Total Alkalinity (TA): The amount of bicarbonates, carbonates, and hydroxides present in SWIMCROSS Exercise System water. Proper total alkalinity is important for pH control. If the TA is too high, the pH is difficult to adjust. If the TA is too low, the pH will be difficult to hold at the proper level. The desired range of TA in

SWIMCROSS Exercise System water is 80 to 120 ppm.

Page 18

Water Quality and Maintenance

c

are and

m

aIntenance

Your ENDLESS POOLS SWIMCROSS Exercise System is manufactured from the highest quality, most durable materials available.

Even so, the SWIMCROSS Exercise System care and maintenance program you develop will ultimately determine how long your

SWIMCROSS Exercise System, and its individual components, will last.

Regular maintenance and following the advice in this section will help you to protect your investment.

FILTER MAINTENANCE

At least once a week, check and clean the skimmer tray to ensure proper filter flow. Remove leaves, foreign matter, and debris. It is very important to keep your SWIMCROSS Exercise System filter cartridges clean and free of particles to ensure proper water flow. Clean filters enables the hydrotherapy system to function properly and allows for more efficient filter cycles. Depending on how frequently your

SWIMCROSS Exercise System is used, we recommend cleaning the

SWIMCROSS Exercise System filter cartridges every four weeks. If this is not done, the filter may clog and restrict water flow, which causes improper filtration, poor jet performance and may possibly freeze.

IMPORTANT: The frequency and duration of use, and the number of occupants all contribute to determining the appropriate time between filter cleanings. More use means that more frequent filter cleanings will be required.

FILTER CARTRIDGE REMOVAL AND

CLEANING INSTRUCTIONS

Place the SWIMCROSS Exercise System in the "Standby" mode, then proceed as follows:

1. Find the filter grate inside the SWIMCROSS Exercise

System.

2. Pull the filter grate from the bottom up until it unlocks from the wall.

IMPORTANT: ONLY

PULL FILTER GRATE UP

SLIGHTLY.

4. Pull skimmer tray away from wall, remove and clean.

5. To remove the filter, turn using the handle in the center of the filter counter-clockwise.

6. Pull filter up, then angle the top away from the filter compartment to pull filter completely out. Each filter has 50 sq. feet of effective filter area.

7. Repeat steps 4 & 5 to remove second filter. Always clean the filter using a filter degreaser to remove mineral and oil buildup. Simply soak the filter in the degreaser (according to the package directions), then place the filter on a clean surface and spray until clean using a garden hose. It may be necessary to rotate the filter while spraying to remove any debris lodged between the filter pleats.

8. Re-insert filter cartridge by reversing steps 5, 6 & 7.

9. Slide skimmer try back into filter compartment reversing step 4.

10. Position filter grate as seen in step 2 & 3, grate should touch wall of

SWIMCROSS Exercise System slightly about black filter equipment compartment tracks. Slide filter grate down until it stops.

Repeat all of the above steps for the filters on the opposite side for the

X500

SWIMCROSS Exercise System.

NOTE: Replacement filter cartridges are available from your ENDLESS

POOLS dealer. Refer to the back of this manual to determine the appropriate size for your SWIMCROSS Exercise System.

3. Pull filter grate away from wall and set aside.

Care and Maintenance

Page 19

DRAINING YOUR

SWIMCROSS

EXERCISE SYSTEM

1. Turn off all GFCI breakers in sub-panel, or main electrical panel.

2. Locate the drain valve (bottom, lower right of control panel) for the SWIMCROSS Exercise

System.

Pull on handle (Figure 1, pliers may be used to pull handle) until you reach the mid position then rotate handle slightly to fully extended drain tube (drain cap and 1” of the drain tube is exposed) (Figure 2) then remove the drain cap

(Figure 3).

NOTE: Do not remove drain cap in mid position. Attach the garden hose to the end of the drain (to avoid flooding of the foundation surrounding the

SWIMCROSS Exercise System) making sure not to push the drain tube inward. Route the outlet of the hose to an appropriate draining area.

Figure 1

Handle

Figure 2

Drain Cap with

Handle

Figure 3

Drain

Tube

NOTE: SWIMCROSS Exercise

System water with a high sanitizer level may harm plants and grass.

3. Push the garden hose and drain tube half-way back towards the

SWIMCROSS Exercise System

(Figure 4) which will start the

Figure 4

gravitational flow. Drain tube must be in the mid position for the

SWIMCROSS Exercise System to drain.

IMPORTANT: All models will drain almost completely through the drain valve. Equipment such as the jet pump and heating system may not completely drain. Any water remaining within the plumbing or equipment after draining will only need to be removed if the

SWIMCROSS Exercise System is being winterized.

4. After your SWIMCROSS Exercise System is empty, clean the shell and filter cartridges.

5. Pull and remove garden hose, replace drain cap and push drain tube back into SWIMCROSS Exercise System as seen in Figure 1.

6. Follow the “START-UP PROCEDURES” to refill your SWIMCROSS

Exercise System.

PREVENTION OF FREEZING

Your SWIMCROSS Exercise System has been designed and engineered for year-round use in any climate. In some areas, extremely cold temperatures (below 10°F) combined with strong wind, may cause partial freezing of the jet pump, even though the water inside the

SWIMCROSS Exercise System remains at the selected temperature.

The energy efficiency of the SWIMCROSS Exercise System may also decrease during these cold periods, as the heater will cycle more frequently. As an additional precaution against partial freezing of some of the components, the equipment compartment can be insulated with an insulating kit available from your local dealer. This insulating kit will also help to maximize the SWIMCROSS Exercise System’s energy efficiency.

NOTE: When warmer weather returns (approx. 60°-70°F), the insulating kit must be removed to prevent overheating of the jet pump.

Page 20

WINTERIZING YOUR

SWIMCROSS

EXERCISE SYSTEM

An ENDLESS POOLS SWIMCROSS Exercise System may be used year round, even in colder climates. If you will not be using the

SWIMCROSS Exercise System during the winter in an area where freezing is a problem, special consideration must be taken to protect the pool and auxiliary equipment if either is located outside. If you have any questions regarding precautions to take against freezing, please call our

Customer Service Department at (800) 999-4688 (extension 8432) or e-mail [email protected].

CARE OF THE PILLOWS

The SWIMCROSS Exercise System pillows will provide years of comfort if treated with care. They have been positioned above the water level to minimize the bleaching effects of chlorinated water and other

SWIMCROSS Exercise System water chemicals. To extend their life, whenever the SWIMCROSS Exercise System shell is being cleaned, the SWIMCROSS Exercise System pillows should be removed and cleaned. Body oils can be removed with a mild soap and water solution.

ALWAYS rinse off the SWIMCROSS Exercise System pillows thoroughly to remove any soap residue. If the SWIMCROSS Exercise System is not going to be used for a long period of time (that is during a vacation or if the SWIMCROSS Exercise System is winterized), or when the

SWIMCROSS Exercise System water is being super-chlorinated, the

SWIMCROSS Exercise System pillows should be removed until the next use of the SWIMCROSS Exercise System.

TO REMOVE AND REPLACE THE

PILLOWS:

1. Carefully lift one end of the pillow away from the SWIMCROSS

Exercise System shell.

2. Continue lifting one end until all pillow retainers are released from the pillow.

IMPORTANT: Just pulling the pillow straight up and out of the shell recess will eventually damage the pillow. This abuse is not covered under warranty.

3. To reinstall the SWIMCROSS Exercise System pillow, carefully bend the pillow slightly to allow one of the pillow retainers to slip into the recess in the back of the pillow.

4. Keeping the pillow slightly bent, slide the other pillow retainer into the recess in the back of the pillow.

5. After all the pillow retainers are in place, press the pillow down into the recess in the

SWIMCROSS Exercise System shell.

Care and Maintenance

CARE OF THE EXTERIOR

SWIMCROSS EXERCISE SYSTEM SHELL

Your ENDLESS POOLS SWIMCROSS Exercise System has an acrylic shell. Stains and dirt generally will not adhere to your SWIMCROSS

Exercise System’s surface. A soft rag or a nylon scrubber should easily remove most dirt. Most household chemicals are harmful to your SWIMCROSS Exercise System’s shell (see below for detailed information on cleaning agents). Always rinse off any SWIMCROSS

Exercise System shell cleaning agent with fresh water.

IMPORTANT:

1. The following products are the ONLY approved cleaning agents for your ENDLESS POOLS SWIMCROSS Exercise System shell: plain water, Spa Shine, Brillianize

®

or Soft Scrub

®

. The use of alcohol or any other household cleaner other than those listed to clean the

SWIMCROSS Exercise System shell surface is NOT recommended.

DO NOT use any cleaning products containing abrasives or solvents since they may damage the shell surface, specifically: Simple

Green

®

, Windex

®

or Spa Mitt. NEVER USE HARSH CHEMICALS!

Damage to the shell by use of harsh chemicals is not covered under the warranty. Always rinse off any SWIMCROSS Exercise System shell cleaning agent with fresh water.

2. Iron and copper in the water can stain the

SWIMCROSS Exercise

System shell if allowed to go unchecked. Ask your

ENDLESS

POOLS dealer about a Stain and Scale Inhibitor to use if your

SWIMCROSS Exercise System has a high concentration of dissolved minerals. (Watkins recommends Stain & Scale Defense.)

3. Keep all cleaners out of the reach of children and use care when applying.

SWIMCROSS EXERCISE SYSTEM CABINET

All SWIMCROSS Exercise Systems use the exclusive all-climate cabinet designed for years of performance. The unique design is made from a rigid polymer for durability and adds a film finish that provides a rich appearance.

Cleaning consists of simply spraying the cabinet with a mild soap and water solution to remove any stains and residue.

Do not rub the cabinet with an abrasive material or use abrasive cleaners as this may damage its surface.

VINYL COVER (OPTIONAL)

The vinyl cover is an attractive, durable foam insulation product. Monthly cleaning and conditioning are recommended to maintain its beauty.

To clean and condition the vinyl cover without a lifter:

1. Remove the covers from the SWIMCROSS Exercise System and gently lean against a wall or fence.

2. With a garden hose, spray the covers to loosen and rinse away dirt or debris.

3. Using a large sponge and/or a soft bristle brush, and using a very mild soap solution (one teaspoon dishwashing liquid with two gallons of water), or baking soda (sodium bicarbonate), scrub the vinyl top in a circular motion. Do not let the vinyl dry with a soap film on it before it can be rinsed clean.

4. Scrub the cover’s perimeter and side flaps. Rinse clean with water.

5. Rinse off the underside of the cover with water only (use no soap), and wipe it clean with a dry rag.

• IMPORTANT: To remove tree sap, use cigarette lighter fluid (not charcoal lighter fluid). Use sparingly, and rinse with a saddle soap solution immediately afterwards, then wipe dry.

Care and Maintenance

Page 21

S

ervIce

I

nformatIon

GENERAL INFORMATION

Your ENDLESS POOLS SWIMCROSS Exercise System has been designed to provide years of trouble-free use. As with any appliance, problems may occasionally occur that require the expertise of a qualified service person. Though such simple repairs as resetting a GFCI switch or breaker, or resetting a high limit thermostat may not require a service call, they may indicate that a more serious condition exists. These conditions may require an experienced service person. Before calling for service, please refer to the Troubleshooting Guide. Always retain your original sales receipt for future reference.

GFCI AND HIGH LIMIT THERMOSTAT

If your SWIMCROSS Exercise System fails to operate at any time, first check the power supply to the SWIMCROSS Exercise System.

Check each of the GFCI breakers in the subpanel. If a GFCI has tripped, reset it. If it will not reset, this may be an indication of a ground fault

(short circuit) within the electrical components. Contact an Authorized

Service Technician for a complete diagnosis.

If upon checking the GFCI’s you find that they have not tripped, check the house breaker panel and ensure the main breaker for the electrical circuit supplying the SWIMCROSS Exercise System has not tripped.

If it has, this is an indication that the circuit was either overloaded or a ground fault exists between the breaker panel and the SWIMCROSS

Exercise System receptacle or subpanel. Contact a qualified electrician.

If upon checking the main house breaker and SWIMCROSS Exercise

System GFCI’s you find no failures, check the high limit thermostat. To check it, simply turn off power to the SWIMCROSS Exercise System for 30 seconds. This will automatically reset the high limit thermostat if it has tripped. If the SWIMCROSS Exercise System energizes once you turn the power back on, this indicates reduced water flow through the heating system. Tripping of the high limit thermostat is normally a result of one or a combination of these problems. 1) clogged filter cartridge(s), 2) blockage within the system plumbing, 3) a nonfunctioning heater circulation pump, 4) power was not disconnected from the SWIMCROSS Exercise System before it was drained, 5) an air lock in the plumbing lines. (The Power Indicator on the front of the

SWIMCROSS Exercise System’s control panel will also be blinking if the high limit thermostat circuit has tripped.)

If the SWIMCROSS Exercise System does not function after tripping and resetting the GFCI’s or resetting the high limit thermostat, then the problem should be referred to an Authorized Service Technician. Refer to the Troubleshooting Guide for additional service information.

MISCELLANEOUS SERVICE

INFORMATION

The control and high-limit thermostats are equipped with electronic sensors that are connected to the SWIMCROSS Exercise System’s plumbing. Never cut or kink the wires that connect the sensors to the thermostats within the control box.

The jet pump is equipped with a thermal overload cutoff switch that is designed to protect the pump from overheating. If the pump shuts itself off in an older SWIMCROSS Exercise System, it could indicate failure of the pump motor bearings. If the pump shuts itself off in a new SWIMCROSS Exercise System, it is usually the result of one or a combination of the following factors:

Page 22

• Thermal overload: Although mass-produced, not all thermal overload cutoffs are exactly the same. Some are more sensitive than others and will shut the pump off at lower temperatures.

• High temperature: All ENDLESS POOLS SWIMCROSS Exercise

System models are equipped with a jet pump shroud that vents the heat generated by the pump motor to the outside of the equipment compartment, and back into the

SWIMCROSS Exercise System water.

If the vent is blocked by masonry, grass or debris, overheating of the jet pump may occur. Once the pump motor has cooled sufficiently and any blockage has been removed from the vent opening, the jet pump can be restarted.

• Friction: Sometimes the moving parts of a new pump are tight enough to cause heat build-up due to friction. After a normal break-in period, the pump will run cooler.

• Improper wiring: If the SWIMCROSS Exercise System is connected with an extension cord, and/or the house wiring is undersized, the pump may starve for voltage and therefore may draw more amperage and generate excessive heat.

• If the pump is shutting down due to excessive heat, make sure the equipment compartment has adequate ventilation. The air gap at the bottom must not be blocked. Should your jet pump continue to shut off after short periods of use, contact a qualified service technician.

ACTS INVALIDATING WARRANTY

The limited warranty is void if the ENDLESS POOLS SWIMCROSS

Exercise System has been improperly installed, subjected to alteration, misuse, or abuse, or if any repairs on the SWIMCROSS

Exercise System are attempted by anyone other than an authorized representative of Watkins Manufacturing Corporation. Alteration shall include any component or plumbing change, electrical conversion, or the addition of any non-approved sanitation or water purification device or heating system which contributes to component or unit failure or unsafe operating system. Misuse and abuse shall include any operation of the SWIMCROSS Exercise System other than in accordance with

Watkins Manufacturing Corporation printed instructions, or use of the SWIMCROSS Exercise System in an application for which it is not designed; specifically: use of the SWIMCROSS Exercise System in a non-residential application; damage caused by operation* of the SWIMCROSS Exercise System at water temperatures outside the range of 35°F and 120°F; damage caused by a dirty, clogged or calcified filter cartridge; damage to the SWIMCROSS Exercise

System surface caused by the use of tri-chloro chlorine, BCDMH, misuse of chemical tablets in a floater, acid, or any other SWIMCROSS

Exercise System chemicals or SWIMCROSS Exercise System surface cleaners which are not recommended by Watkins Manufacturing

Corporation; damage caused by allowing undissolved SWIMCROSS

Exercise System sanitizing chemicals to lie on the SWIMCROSS

Exercise System surface (no SWIMCROSS Exercise System surface material can withstand this kind of abuse); damage to components or

SWIMCROSS Exercise System surface caused by improper water chemistry maintenance; and damage to the SWIMCROSS Exercise

System surface caused by leaving the SWIMCROSS Exercise System uncovered while empty of water and in direct exposure to sunlight (this may cause solar heating distress in warm weather regions). These are considered abuses and may invalidate this warranty.

*Operation of the SWIMCROSS Exercise System does not mean

“use” of the

SWIMCROSS Exercise System! Watkins Manufacturing

Corporation does not recommend using the SWIMCROSS Exercise

System if the water temperature is above or below the

SWIMCROSS

Exercise System’s control panel temperature range.

Service Information

DISCLAIMERS

Watkins Manufacturing Corporation shall not be liable for loss of use of the ENDLESS POOLS SWIMCROSS Exercise System, or other incidental, consequential, special, indirect, or punitive costs, expenses or damages, which may include but are not limited to the removal of a permanent deck or other custom fixture, or the necessity for crane removal. Any implied warranty shall have a duration equal to the duration of the applicable limited warranty stated above. Some states do not allow limitations on how long an implied warranty lasts. Under no circumstances shall Watkins Manufacturing Corporation or any of its representatives be held liable for injury to any person or damage to any property, however arising.

Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations may not apply to you.

WATKINS CUSTOMER SERVICE

If you have any questions about any aspect of your

ENDLESS POOLS

SWIMCROSS Exercise System set-up, operation or maintenance that have not been answered by this manual, consult your

ENDLESS

POOLS dealer.

Watkins Manufacturing Corporation can be reached at: 800-999-4688

(extension 8432), Monday through Friday, 8 am to 5-pm Pacific Standard

Time (PST), or e-mail [email protected].

TROUBLESHOOTING

Should you experience any problem whatsoever, do not hesitate to contact your authorized ENDLESS POOLS dealer. Located below and on the next page are some tips to help you to diagnose and rectify some more common sources of trouble yourself, if you choose to do so.

SWIMCROSS EXERCISE SYSTEM WATER MAINTENANCE TROUBLESHOOTING GUIDE

Problem

Cloudy Water

Water Odor

Chlorine Odor

Musty Odor

Organic buildup / scum ring around

SWIMCROSS

Exercise System

Algae Growth

Eye Irritation

Skin Irritation / Rash

Stains

Scale

Probable causes

• Dirty filters

• Excessive oils / organic matter

• Improper sanitization

• Suspended particles / organic matter

• Overused or old water

• Excessive organics in water

• Improper sanitization

• Low pH

• Chloramine level too high

• Low pH

• Bacteria or algae growth

• Build-up of oils and dirt

• High pH

• Low sanitizer level

• Low pH

• Low sanitizer level

• Unsanitary water

• Free chlorine level above 5 ppm

• Total alkalinity and/or pH too low

• High iron or copper in source water

• High calcium content in water – total alkalinity and pH too high

Solutions

• Clean filters

• Shock SWIMCROSS Exercise System with sanitizer

• Add sanitizer

• Adjust pH and/or alkalinity to recommended range

• Run jet pump(s) and clean filters

• Drain and refill the

SWIMCROSS Exercise System

• Shock

SWIMCROSS Exercise System with sanitizer

• Add sanitizer

• Adjust pH to recommended range

• Shock SWIMCROSS Exercise System with sanitizer

• Adjust pH to recommended range

• Shock SWIMCROSS Exercise System with sanitizer–if problem is visible or persistent, drain, clean and refill the SWIMCROSS Exercise System

• Wipe off scum with clean rag – if severe, drain the SWIMCROSS Exercise

System, use a SWIMCROSS Exercise System surface and tile cleaner to remove the scum, and refill the SWIMCROSS Exercise System

• Shock SWIMCROSS Exercise System with sanitizer and adjust pH

• Shock SWIMCROSS Exercise System with sanitizer and maintain sanitizer level

• Adjust pH

• Shock SWIMCROSS Exercise System with sanitizer and maintain sanitizer level

• Shock SWIMCROSS Exercise System with sanitizer and maintain sanitizer level

• Allow free chlorine level to drop below 5 ppm before

SWIMCROSS Exercise

System use

• Adjust total alkalinity and/or pH

• Use a metal deposit inhibitor

• Adjust total alkalinity and pH – if scale requires removal, drain the SWIMCROSS

Exercise System, scrub off the scale, refill the SWIMCROSS Exercise System and balance the water

Service Information

Page 23

Problem

Entire SWIMCROSS Exercise

System is inoperative

SWIMCROSS Exercise System does not heat; jets and light operate

GENERAL OPERATION TROUBLESHOOTING GUIDE

Probable causes

• Power failure

• GFCI tripped

• Heater high-limit thermostat tripped

• Integrated pressure switch open

Solutions

• Check power source

• Reset GFCI; call for service if it will not reset

• Disconnect power for at least thirty seconds to reset heater high limit. If it will not reset, check for clogged filters. If tripping continues, call for service.

• Check for clogged filters. Integrated pressure switch will reset when the flow of water through the heater has been restored. Call for service if the heater trips frequently.

• Circulation pump thermal cut-off tripped

Jets weak or surging

• Check for clogged filters or air locks in plumbing. Disconnect power to the

SWIMCROSS Exercise System, allow circulation pump to cool. Circulation pump thermal cut-off will reset when pump has cooled and power is reapplied. Call for service if circulation pump thermal cut-off trips frequently.

• Check which Water Care Mode your are in and change if necessary.

• Add water

Lights inoperative

SWIMCROSS Exercise System not heating properly

Pump motor will not function

• Water Care Mode

• SWIMCROSS Exercise System water level too low

• Filters clogged

• Water valves are closed

• Light wiring or assembly is faulty

• Temperature set too low

• SWIMCROSS Exercise System cover improperly positioned

• Dirty Filter

• Water Care Mode

• Motor overload condition

• Clean filters

• Open water valves

• Call for service, replace light assembly

• Set control panel to a higher temperature.

• Align SWIMCROSS Exercise System cover

• Clean filter

• Check which Water Care Mode your are in and change if necessary.

• Let cool for one hour. Motor overload will reset automatically. If problem persists, contact your ENDLESS POOLS dealer

• Disconnect SWIMCROSS Exercise System and contact your ENDLESS POOLS dealer

Noisy pump or motor

Pump motor runs, but low or no water/ jet pressure

After filling or refilling the SWIMCROSS

Exercise System: a jet pump is operating, but water is not flowing from any of its jets

• Control switch failure if jet symbol does not come on

• Low water level

• Air control valve closed

• Water Valves are closed

• Dirty filter cartridge

• Jet blocked

• Clogged suction or skimmer basket

• Pump is not properly primed

• Add water to normal level (6 inch below bar top)

• Open air valve

• Open any closed water valves

• Clean filter cartridge

• Remove jet face eyeball and clean orifice

• Clean suction cover or skimmer basket

• Turn off power to the SWIMCROSS Exercise System at the breaker and remove the equipment compartment door.

• Loosen the union on the top of the pump(s) to allow the air to escape, and then handtighten the union(s).

• Turn power back on, activate the pump, and check to make sure the union is tight enough to keep it from leaking. Replace the equipment doors.

Error Code

HR

HL

AOH

FLO

Prr

OH

UPL

TROUBLESHOOTING ERROR CODES

Cause & Solution

An internal hardware error has been detected . Reset the breaker, if the problem persists, call for service.

The system has shut the heater down because the temperature at the heater has reached 119°F (48°C). Do not enter the water!

Remove the cover and allow the water to cool down, then shut power off and power back up again to reset the system.

Temperature inside the equipment compartment is too high, causing the internal temperature in the control box to increase above normal limits. Shut off power, open equipment compartment and allow area to cool. Close equipment compartment and repower once compartment has cooled down.

The system does not detect any water flow while the primary pump is running. Check and open water valves. Check for water level.

Clean filter. If the problem persists, call for service.

A problem is detected with the temperature probe. Call for service.

The water temperature has reached 108°F (42°C). Do not enter the water! Remove the cover and allow the water to cool down to a lower temperature. Call for service if problem persists.

No low-level configuration software has been installed into the system. Call for service.

Page 24

Service Information

SWIMCROSS EXERCISE SYSTEM SPECIFICATIONS

This manual contains installation, operating, maintenance, and service information for the following ENDLESS POOLS SWIMCROSS Exercise System

X200

X500

12'0" x

7'5"

15'0" x

7'5"

Footprint dimensions

50"

50"

Height

Ef fective filter area

Heater

(W atts)

100 square feet

4,000

200 square feet

4,000

1,210 gallons

1,650 gallons

W ater capacity

Dry weight

Filled weight*

2,225 lbs.

2,670 lbs.

14,070 lbs.

18,185 lbs.

185 lbs. per square foot

190 lbs. per square foot

Dead weight

Electrical

Requirements

230 volt, 60 amp

Single phase GFCI protected circuit

230 volt, 60 amp

Single phase GFCI protected circuit

CAUTION: Watkins Manufacturing Corporation suggests a structural engineer or contractor be consulted before the

SWIMCROSS Exercise System is placed on an elevated deck.

* NOTE: The “Filled weight” and “Dead weight” of the

SWIMCROSS Exercise System includes the weight of 10 occupants

(assuming an average occupant weight of 175 lbs).

©2016 WATKINS MANUFACTURING CORPORATION. ENDLESS POOLS IS A TRADEMARK OF WATKINS MANUFACTURING CORPORATION

Watkins Manufacturing Corporation

Vista, California

USA

305033.16 E (6/16)