Installation Instructions
FSR
CEILING TILE INSTRUCTIONS
8. INSTALL 14-3/8" x 22-3/4" DROP CEILING MATERIAL (SUPPLIED
BY CUSTOMER) INTO DOOR. BEND CAPTURE TABS OVER
CEILING PANEL TO HOLD IN PLACE.
CB-22P INSTALLATION INSTRUCTIONS
244 Bergen Boulevard, Woodland Park, NJ 07424, Phone: 973.785.4347 - Fax: 973.785.4207
1. INSTALL CB-22P TO A STRUCTURAL CEILING ABLE TO
SUPPORT FIVE TIMES THE NOTED GROSS WEIGHT. USE
APPROPRIATE MOUNTING METHODS BASED ON LOCAL
BUILDING CODES. INSTALL SAFETY CABLE AS REQUIRED BY
LOCAL BUILDING CODES. ROUTE CONDUITS TO BOX AS
REQUIRED.
STRUCTURAL
MEMBER
NOTE: MAXIMUM GROSS WEIGHT - 120 LBS
b
14-3/8" x 22-3/4"
DROP CEILING
PANEL MATERIAL
(SUPPLIED BY
CUSTOMER)
a
(4) CAPTURE
TAB
DOOR IS REMOVABLE.
(a) PUSH DOOR UP
TOWARDS CEILING AND
(B) PUSH TOWARDS
SHELF - REVERSE
PROCEDURE TO
INSTALL.
DISCONNECT SAFETY
CABLE TO COMPLETELY
REMOVE DOOR.
LOOSEN SCREWS
TO OPEN DOOR
9. REMOVE CEILING BOX DOOR (SEE STEP 8), REMOVE
(2) #8-32 SCREWS AND ADJUSTMENT BAR COVER. SUPPORT
ADJUSTMENT BAR COVER WHILE REMOVING SCREWS.
POLE MOUNT FLANGE COVER IS NOT FASTENED AND JUST
SLIPS OUT. INSTALL (2) 4" WIDE (SEE NOTE) DROP CEILING
PANELS MATERIAL (SUPPLIED BY CUSTOMER) INTO POLE
ADJUSTMENT BAR. CUT LENGTH AS NEEDED BASED ON
POLE MOUNT POSITION.
ALL MOUNTING HARDWARE
SUPPLIED BY CUSTOMER
NOTE: THREADED ROD IS THE
RECOMMENDED CEILING BOX
MOUNTING SUSPENSION
(SHOWN), TO MINIMIZE
FIXTURE TILTING DUE
TO THE WEIGHT OF ANY
SUSPENDED EQUIPMENT.
STRUCTURAL
CHANNEL
14 GA. STEEL TIE WIRE MAY BE USED
(SUPPLIED BY CUSTOMER OR USE FSR KIT)
AT 70,000 PSI TENSILE STRENGTH OR
BETTER AS REQUIRED BY BUILDING CODES.
NOTE: WIRES SUPPORT CEILING
BOX, AND ARE NOT SAFETY CABLES
THREADED ROD OR CABLE TO
BE PLUMB WITH CEILING AND FLOOR
AVAILABLE KITS (SOLD SEPARATELY):
CB-MNT1 - CABLE INSTALLATION KIT
CB-THRD - THREADED ROD INSTALLATION KIT
ROUTE CONDUIT
(SUPPLIED BY
CUSTOMER) TO
KNOCKOUTS
AS REQUIRED
2. TO INSTALL AC MAIN POWER INTO THE UNIT, REMOVE THE
AC ACCESS PLATE BY REMOVING (4) #8-32 SCREWS, AS
SHOWN. WIRING MUST BE PERFORMED BY A QUALIFIED
ELECTRICIAN ONLY. WIRING MUST BE DONE IN
ACCORDANCE WITH ALL NEC AND OTHER APPLICABLE
CODES. RE-INSTALL AC ACCESS PLATE AFTER AC WIRING IS
COMPLETE.
NOTE: 4" x 9" PANEL SIZE IS ONLY VALID WHEN POLE MOUNT
FLANGE IS CENTERED ON THE POLE ADJUSTMENT
BAR (DEFAULT FACTORY INSTALLED LOCATION). IF
POLE MOUNT IS RELOCATED PANELS WILL NEED TO
BE CUT-TO-FIT.
BRACKET - FSR'S
THREADED ROD
INSTALLATION KIT
(HARDWARE SUPPLIED
BY CUSTOMER)
3. IF POLE MOUNT FLANGE IS TO BE LEFT AT FACTORY
POSITION, PROCEED TO STEP 7. IF FLANGE IS TO BE
RE-POSITIONED, OR IF INSTALLING FAN KIT, REMOVE
CEILING BOX DOOR. LOOSEN SCREWS TO OPEN DOOR.
(a) PUSH DOOR UP TOWARDS CEILING AND (b) PUSH
TOWARDS SHELF - REVERSE PROCEDURE TO INSTALL.
DISCONNECT SAFETY CABLE TO COMPLETELY REMOVE
DOOR.
SHELF
POLE MOUNT FLANGE
(SHOWN CENTERED)
4" WIDE DROP CEILING PANEL
MATERIAL - SEE STEP 10 NOTE
(SUPPLIED BY CUSTOMER)
b
(4) #8-32 x 1/4"LONG PAN
HEAD SCREW
(2) #8-32 x 1/4"-LONG
PAN HEAD SCREW
AC POWER INPUT
WIRING MUST BE
PERFORMED BY
A QUALIFIED
ELECTRICIAN ONLY
POLE MOUNT FLANGE COVER
ADJUSTMENT BAR COVER
FSR Inc.
244 Bergen Boulevard, Woodland Park, NJ 07424
Phone: 973.785.4347 - Fax: 973.785.4207
Web: www.fsrinc.com - E-mail: [email protected]
a
AC ACCESS
PLATE
LOOSEN SCREWS
TO OPEN DOOR
43195
LIT1326B
MOUNTING ELECTRONICS INSTRUCTIONS
4. REMOVE (2) #8-32 SCREWS AS SHOWN, AND REMOVE
ADJUSTMENT BAR COVER. SUPPORT ADJUSTMENT BAR
COVER WHILE REMOVING SCREWS. POLE MOUNT FLANGE
COVER IS NOT FASTENED AND JUST SLIPS OUT.
PART OF
POLE MOUNT
FLANGE
COVER
7a. REMOVE SHELF, AND MOUNT ELECTRONICS TO SHELF. USE
HOLE/SLOT PATTERN ON SHELF TO MOUNT EQUIPMENT...
ADDITIONAL HOLES MAY BE REQUIRED (SEE 8b. FOR
INSTALLING RACK MOUNTED UNITS). RE-INSTALL SHELF INTO
CB-22P. MAKE ELECTRICAL CONNECTIONS AS REQUIRED.
SCREWS LOCATED IN
INTERIOR OF CEILING BOX
NOTE: MAXIMUM LOAD PER SHELF - 20 LBS EACH
LOOSEN SCREWS
(4 PER SHELF)
TO REMOVE
SHELVES
FLANGE
(2) SHELF
(2) #8-32 x 1/4"-LONG
PAN HEAD SCREW
POLE MOUNT FLANGE COVER
a
LOOSEN SHELF SCREWS.
(a) PUSH SHELF TOWARDS
DOOR AND (b) SHELF WILL
DROP DOWN OUT OF CB-22P
ADJUSTMENT BAR COVER
b
INSTALLING OPTIONAL FAN KIT:
5. DETERMINE LOCATION OF POLE MOUNT FLANGE. LOOSEN
(4) #10-32 HEX SCREWS AND SLIDE POLE MOUNT FLANGE
TO NEW POSITION AND TIGHTEN HEX SCREWS. IF
INSTALLING FAN KIT PROCEED TO STEP 6. RE-INSTALL
POLE MOUNT FLANGE COVER, ADJUSTMENT BAR COVER
AND CEILING BOX DOOR BACK INTO CEILING BOX BY
REVERSING THEIR REMOVAL STEPS. PROCEED TO STEP 7.
NOTE: MAXIMUM PROJECTOR LOAD INCLUDING MOUNTED
ACCESSORIES - 50LBS
6. REMOVE (4) #8-32 SCREWS AS SHOWN, AND EXTRACT
POLE ADJUSTMENT BAR. INSTALL FAN KIT PER
INSTRUCTIONS. RE-INSTALL POLE ADJUSTMENT BAR,
POLE MOUNT FLANGE COVER, ADJUSTMENT BAR COVER
AND CEILING BOX DOOR BACK INTO CEILING BOX BY
REVERSING THEIR REMOVAL STEPS. PROCEED TO STEP 7.
CAUTION: ONCE THE LAST SCREW IS REMOVED
FROM THE POLE ADJUSTMENT BAR, IT
CAN FALL OUT. HOLD POLE ADJUSTMENT
BAR IN PLACE WHILE REMOVING SCREWS.
HOLES FOR ALTERNATE
LOCATION OF SHELVES
7b. FOR 1RU x 19" EIA RACK-SIZED ELECTRONICS, INSTALL RACK
MOUNT BRACKETS AS SHOWN. ATTACH RACK UNIT, AND
RE-INSTALL SHELF INTO CB-22P. MAKE ELECTRICAL
CONNECTIONS AS REQUIRED.
NOTE: MAXIMUM LOAD PER SHELF - 20 LBS EACH
RIGHT RACK
MOUNT
BRACKET
LEFT RACK
MOUNT
BRACKET
TOWARDS
BOX BLANK
END
(4) #10-32 x 3/4"-LONG
HEX SCREW
NOTE: THE CENTER OF MASS
OF SUSPENDED EQUIPMENT MUST BE WITHIN
A 2.5" RADIUS OF THE
CENTER LINE OF THE
POLE MOUNT FLANGE
OF THE CEILING BOX.
POLE
ADJUSTMENT
BAR
POLE MOUNT FLANGE
(4) #8-32 x 3/8"-LONG
FLAT HEAD SCREW
SHELF
(4) #10-32 x 3/8"-LONG
PAN HEAD SCREW
ALTERNATE
MOUNTING
HOLES FOR RACK
MOUNT BRACKETS
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement