Master-Bilt TEL, TEM Refrigerator Installations & Operations Manual

Below you will find brief information for Refrigerator TEL, Refrigerator TEM. This document will help you to install and operate your new refrigerator. It also includes information on troubleshooting and maintenance.

PDF Download
Document
Refrigerator TEL, Refrigerator TEM Installations & Operations Manual | Manualzz

Advertisement

Advertisement

Advertisement

Key Features

  • LAE Electronic Control
  • Condensate drain
  • Cleanout drain
  • Refrigeration system evacuation and charging
  • LED driver replacement
  • Door heater replacement
  • Service and troubleshooting information

Frequently Answers and Questions

How do I install the condensate drain?

The TEL/TEM is equipped with a condensate drain that is piped out the middle front of the cabinet. This drain line is 1” PVC pipe that must be have a P-trap installed. It is very important that this trap be installed as it will result in diminished performance of the case without it. There is also a 1” cleanout drain in the middle front of the bottom the cabinet. The kickplate will need to be removed to see the piping for the cleanout drain. 1. Always install drains in accordance with local codes. 2. Use largest possible size pipe for drains, one inch minimum is recommended. 3. Provide as much downhill slope as possible. 4. Prevent drains from freezing. Do not install drains in contact with uninsulated suction lines.

How do I evacuate and charge the refrigeration system?

1. Blow out all refrigerant lines with dry nitrogen or carbon dioxide to eliminate the possibility of dirt, scale, etc. remaining inside. 2. Connect all lines and leak test all connections. 3. Connect a good high vacuum pump to both the low and high side evacuation valves. 4. Operate the pump until a vacuum of 1500 microns (0.06 inches of mercury) absolute pressure is obtained. At this point, the vacuum should be broken by the introduction of refrigerant into the system, through a drier, until the pressure is brought up to zero pounds gauge. Repeat this procedure two more times. During the final evacuation, a vacuum of 500 microns (0.02 inches of mercury) absolute pressure should be obtained. After this vacuum is reached, the system can be fully charged with refrigerant.

How do I replace the LED driver?

For a TEL/TEM, the LED Drivers are located inside the door mullions and can be accessed from the front of the door frame. Remove the door that hinges on the mullion where the ballast will be replaced. From the front of frame, remove contact plate & retainer by inserting a flat-head screwdriver under back edge of black contact plate retainer, and gently pull to unsnap retainer from the mullion. Repeat for the other side, and remove the contact plate. With the ballast now exposed, remove the screw on the top end of the ballast. Loosen the screw on the bottom of the driver. Disconnect all lead wires by separating the connectors. If cut, leave enough lead wire to re-connect the new driver with a wire nut. Insert the bottom of the new ballast in the punched tabs and re-install the top screw in the top end of the driver. Tighten both screws. Re-connect new driver’s lead wires following the wiring diagrams provided.