- Industrial & lab equipment
- Electrical equipment & supplies
- Power conditioning
- Uninterruptible power supplies (UPSs)
- User manual
advertisement
SmartOnline 200-240V 6kVA 4.2kW On-Line
Double-Conversion UPS, Extended Run, SNMP,
Webcard, 6U Rack/Tower, DB9 Serial, Hardwire
MODEL NUMBER: SU6000RT3UHV
Highlights
6000VA / 6kVA / 4200W on-line double-conversion UPS
200/208/220/230/240V 50/60Hz output, Economy mode option
6U Rack/Tower compatible;
Hot-swappable battery modules
RS232 & EPO ports; support for
SNMP/WEB card options
Front panel LEDs with detailed
LCD monitoring and control screen
Ships with standard capacity
BP240V7RT3U battery pack
Hardwire input (3 wire); Hardwire output
Package Includes
SU6000RT3UPM 3U Power
Description
Tripp Lite Smart Online UPS systems offer high performance power protection ideal for critical server and network equipment in datacenters, computer rooms and network closets. Online, double-conversion
Uninterruptible Power Supply (UPS) maintains perfectly regulated output power by continuously converting raw
AC input to DC, then re-converting output back to AC. Fully regulated sine wave AC output with +/-2% voltage regulation powers network equipment continuously, even during severe brownouts and overvoltages, all without depleting UPS battery reserves. Maintains battery-derived AC output during power failures with zero transfer time. Extended runtime options available. Interactive LCD interface reports UPS operating mode, detailed UPS and site-power data, plus enables a variety of UPS setup and configuration options. Highly efficient operation in optional economy mode saves BTU heat output and energy costs. Network management interfaces support
Module
BP240V7RT3U non-expandable
3U battery pack
PowerAlert software and complete cabling
Complete mounting hardware for
4 post rack installation
2-9USTAND tower stand set
Warranty information
Instruction manual communications via RS-232, contact-closure and optional SNMPWEBCARD network interface. Built-in DB9 port offers both enhanced RS-232 data and basic contact closure monitoring ability. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. LED display reports
UPS operating mode, line power availability, battery mode operation, inverter operation, ECO mode status and output power availability. Audible alarm with push-button momentary alarm-cancel and silent-mode LCD configuration options. Programmable self-test. Fault-tolerant auto-bypass mode. Field-replaceable, hot-swappable internal batteries and external battery packs.
Features
True on-line, double conversion UPS provides pure, sine wave AC output at all times
World-wide compatibility with Euro 50Hz and High Voltage North American 60Hz power
Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time
Removes harmonic distortion, electrical impulses, frequency variations and other hard to solve power problems
6000VA/4200 watt power capacity with hardwire input/output connections
Accepts input voltages between 156 and 276, regulating output within 2% of selectable 200/208/220/230/240v AC output
20 minutes runtime at half load (2100W) / 8 minutes at full load (4200W) with included BP240V7RT3U external battery pack
Expandable runtime with multiple external battery packs
1 / 6
Innovative design makes unit adaptable for rackmount, tower, or stacking applications
Power module and battery pack require only 3 rack spaces each (6U total rack space usage)
DB9 serial port for network interface; SNMP compatible
Slot for optional SNMP/web card (part# SNMPWEBCARD)
PowerAlert unattended shutdown software and 6 ft. network cable included
Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
Diagnostic LEDs
Mounting hardware included with each 3U module for 4 post rackmount installation, 2 post telecom rack compatible with separate purchase
2POSTRMKITHD (2 required)
Includes RJ11 EPO (emergency power off) port and interconnection cable
$250,000 Ultimate Lifetime Insurance (USA , Puerto Rico, & Canada Only)
Specifications
OUTPUT
Output Capacity Details
Output Volt Amp Capacity (VA)
Output kVA Capacity (kVA)
Output Watt Capacity (Watts)
Output kW Capacity (kW)
Power Factor
Crest Factor
Nominal Output Voltage(s)
Supported
Nominal Voltage Details
Frequency Compatibility
Frequency Compatibility Details
Output Voltage Regulation (Line
Mode)
Output Voltage Regulation
(Economy Line Mode)
Supports up to 102% load continuously in double conversion mode, 102 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power;
Double conversion mode is automatically restored as load levels are reduced to 90% or less
6000
6
4200
4.2
0.7
3:1
200V; 208V; 220V; 230V; 240V
Voltage selection via front panel LCD interface
50 / 60 Hz
Output frequency matches input nominal on startup
+/- 2%
+/- 10%
Output Voltage Regulation (Battery
Mode)
Output Receptacles
+/- 2%
Hardwire
Output Receptacle Backplate
Options
Output Circuit Breakers
Output AC Waveform (AC Mode)
Optional SUPDM11 backplate adds 2 L6-30R outlets and L6-30P input cord
40A double-pole
Pure Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
2 / 6
INPUT
Rated input current (Maximum Load) 30A
Nominal Input Voltage(s) Supported 200V AC; 208V AC; 220V AC; 230V AC; 240V AC
UPS Input Connection Type Hardwire
UPS Input Connection Description
Supports North American 208/240V input (L1,L2,G) and International 230/220/240V (L,N,PE) input wiring; Optional
SUPDM11 backplate adds 2 L6-30R outlets and L6-30P input cord
Input Circuit Breakers
Recommended Electrical Service
Input Phase
40A double-pole
30A 208/220/230/240V
Single-Phase
BATTERY
Full Load Runtime (min.)
Half Load Runtime (min.)
Expandable Battery Runtime
External Battery Pack Compatibility
DC System Voltage (VDC)
Battery Recharge Rate (Included
Batteries)
Battery Replacement Description
8 min. (4200w)
20 min. (2100w)
Includes one non-expandable BP240V7RT3U (limit 1) external battery pack. No additional BP240V7RT3U external battery packs can be connected to the host UPS, beyond the one included with the SU6000RT3UHV UPS bundle.
All additional battery packs connected beyond the included BP240V7RT3U, must be BP240V10RT3U,
BP240V557C-1PH, BP240V787C-1PH, BP240V1037C-1PH or BP240V1407C-1PH
BP240V10RT3U; BP240V557C-1PH; BP240V787C-1PH; BP240V1037C-1PH; BP240V1407C-1PH
240
Less than 6 hours from 10% to 80% (typical, full load discharge)
Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage Regulation Description
Overvoltage Correction
Undervoltage Correction
LEDS ALARMS & SWITCHES
LED Indicators
Front Panel LCD Display
Audible Alarm
Alarm Cancel Operation
Switches
Online, double-conversion power conditioning
2% output voltage regulation during overvoltages to 276
2% output voltage regulation during undervoltages to 156
6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options
Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options;
LED/LCD panel rotates for viewing in rack/tower formats (see manual)
Unique audible alarms for all major UPS, environmental and power conditions (see manual)
Alarm cancel switch
2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions
SURGE / NOISE SUPPRESSION
3 / 6
UPS AC Suppression Response
Time
EMI / RFI AC Noise Suppression
Instantaneous
Yes
PHYSICAL
Included Mounting Accessory
Description
2 sets of adjustable 4 post rack rails included (for UPS and battery pack components); 2-9USTAND tower kit included (supports up to 9U in tower format)
Installation Form Factors Supported with Optional Accessories
2 post rackmount (2POSTRMKITHD)
Optional Mounting Accessory Notes 2 sets of 2POSTRMKITWM required for 2 post rackmount installation of separate power module and battery pack
Primary Form Factor Rackmount
UPS Power Module Dimensions
(hwd, in.)
UPS Power Module Dimensions
(hwd, cm)
Installed Whole System Maximum
Rack Depth (in.)
5.2 x 17.5 x 26
13.3 x 44.4 x 66
26
Installed Whole System Maximum
Rack Depth (cm)
Rack Height (U Spaces)
UPS Power Module Weight (lbs.)
UPS Power Module Weight (kg)
UPS Dimensions Details
Stepdown Transformer Dimensions
(hwd / in.)
Stepdown Transformer Dimensions
(hwd / cm)
Included Battery Pack Dimensions
(hwd / in.)
66
6
43.8
19.9
Includes 3U power module and 3U battery pack
5.2 x 17.5 x 25
Included Battery Pack Dimensions
(hwd / cm)
Included Battery Pack Weight (lbs.)
Included Battery Pack Weight (kg)
13.3 x 44.4 x 63.5
136.5
62
UPS Shipping Dimensions (hwd / in.) 24.5 x 24 x 35
UPS Shipping Dimensions (hwd / cm)
62.2 x 61 x 88.9
Shipping Weight (lbs.)
Shipping Weight (kg)
Cooling Method
UPS Housing Material
323
146.6
Fan
Steel
4 / 6
ENVIRONMENTAL
Operating Temperature Range
Storage Temperature Range
Relative Humidity
AC Mode BTU / Hr. (Full Load)
AC Economy Mode BTU / Hr. (Full
Load)
AC Mode Efficiency Rating (100%
Load)
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.
0 to 95%, non-condensing
1412.3
911.5
91%
AC Economy Mode Efficiency Rating
(100% Load)
94%
Operating Elevation (ft.)
Audible Noise
0-3000m (0 to 10,000 ft.)
60 dBA at front side 1 meter
COMMUNICATIONS
Communications Interface DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface
Network Monitoring Port Description RS232 and contact closure communications are located on two separate DB9 ports
PowerAlert Software
Communications Cable
Included
DB9 cable included
LINE / BATTERY TRANSFER
Transfer Time
Transfer Time (Economy Mode)
Low Voltage Transfer to Battery
Power (Setpoint)
High Voltage Transfer to Battery
Power (Setpoint)
No transfer time (0 ms.) in online, double-conversion mode
Less than 1ms typical power failure response in optional economy mode
156
276
SPECIAL FEATURES
Cold Start (Startup in Battery Mode
During a Power Failure)
High Availability UPS Features
Green Energy-Saving Features
Cold-start operation supported
Automatic inverter bypass; Hot swappable batteries
High efficiency economy mode operation; Schedulable daily hours of economy mode operation
CERTIFICATIONS
UPS Certifications
Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); CE; Tested to GOST (Russia);
Tested to SASO (Saudi Arabia); Tested to IRAM (Argentina); Meets FCC Part 15 Category A (EMI); ROHS
(Restriction of Hazardous Substances)
WARRANTY
5 / 6
Product Warranty Period (Worldwide) 2-year limited warranty
© 2015 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous improvement.
Specifications are subject to change without notice. Photos may differ slightly from final products.
6 / 6
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project