SmartOnline 200-240V 6kVA 4.2kW On-Line Double

Add to my manuals
6 Pages

advertisement

SmartOnline 200-240V 6kVA 4.2kW On-Line Double | Manualzz

SmartOnline 200-240V 6kVA 4.2kW On-Line

Double-Conversion UPS, Extended Run, SNMP,

Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

MODEL NUMBER: SU6000RT3UHV

Highlights

6000VA / 6kVA / 4200W on-line double-conversion UPS

200/208/220/230/240V 50/60Hz output, Economy mode option

6U Rack/Tower compatible;

Hot-swappable battery modules

RS232 & EPO ports; support for

SNMP/WEB card options

Front panel LEDs with detailed

LCD monitoring and control screen

Ships with standard capacity

BP240V7RT3U battery pack

Hardwire input (3 wire); Hardwire output

Package Includes

SU6000RT3UPM 3U Power

Description

Tripp Lite Smart Online UPS systems offer high performance power protection ideal for critical server and network equipment in datacenters, computer rooms and network closets. Online, double-conversion

Uninterruptible Power Supply (UPS) maintains perfectly regulated output power by continuously converting raw

AC input to DC, then re-converting output back to AC. Fully regulated sine wave AC output with +/-2% voltage regulation powers network equipment continuously, even during severe brownouts and overvoltages, all without depleting UPS battery reserves. Maintains battery-derived AC output during power failures with zero transfer time. Extended runtime options available. Interactive LCD interface reports UPS operating mode, detailed UPS and site-power data, plus enables a variety of UPS setup and configuration options. Highly efficient operation in optional economy mode saves BTU heat output and energy costs. Network management interfaces support

Module

BP240V7RT3U non-expandable

3U battery pack

PowerAlert software and complete cabling

Complete mounting hardware for

4 post rack installation

2-9USTAND tower stand set

Warranty information

Instruction manual communications via RS-232, contact-closure and optional SNMPWEBCARD network interface. Built-in DB9 port offers both enhanced RS-232 data and basic contact closure monitoring ability. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. LED display reports

UPS operating mode, line power availability, battery mode operation, inverter operation, ECO mode status and output power availability. Audible alarm with push-button momentary alarm-cancel and silent-mode LCD configuration options. Programmable self-test. Fault-tolerant auto-bypass mode. Field-replaceable, hot-swappable internal batteries and external battery packs.

Features

True on-line, double conversion UPS provides pure, sine wave AC output at all times

World-wide compatibility with Euro 50Hz and High Voltage North American 60Hz power

Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time

Removes harmonic distortion, electrical impulses, frequency variations and other hard to solve power problems

6000VA/4200 watt power capacity with hardwire input/output connections

Accepts input voltages between 156 and 276, regulating output within 2% of selectable 200/208/220/230/240v AC output

20 minutes runtime at half load (2100W) / 8 minutes at full load (4200W) with included BP240V7RT3U external battery pack

Expandable runtime with multiple external battery packs

1 / 6

Innovative design makes unit adaptable for rackmount, tower, or stacking applications

Power module and battery pack require only 3 rack spaces each (6U total rack space usage)

DB9 serial port for network interface; SNMP compatible

Slot for optional SNMP/web card (part# SNMPWEBCARD)

PowerAlert unattended shutdown software and 6 ft. network cable included

Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions

Diagnostic LEDs

Mounting hardware included with each 3U module for 4 post rackmount installation, 2 post telecom rack compatible with separate purchase

2POSTRMKITHD (2 required)

Includes RJ11 EPO (emergency power off) port and interconnection cable

$250,000 Ultimate Lifetime Insurance (USA , Puerto Rico, & Canada Only)

Specifications

OUTPUT

Output Capacity Details

Output Volt Amp Capacity (VA)

Output kVA Capacity (kVA)

Output Watt Capacity (Watts)

Output kW Capacity (kW)

Power Factor

Crest Factor

Nominal Output Voltage(s)

Supported

Nominal Voltage Details

Frequency Compatibility

Frequency Compatibility Details

Output Voltage Regulation (Line

Mode)

Output Voltage Regulation

(Economy Line Mode)

Supports up to 102% load continuously in double conversion mode, 102 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power;

Double conversion mode is automatically restored as load levels are reduced to 90% or less

6000

6

4200

4.2

0.7

3:1

200V; 208V; 220V; 230V; 240V

Voltage selection via front panel LCD interface

50 / 60 Hz

Output frequency matches input nominal on startup

+/- 2%

+/- 10%

Output Voltage Regulation (Battery

Mode)

Output Receptacles

+/- 2%

Hardwire

Output Receptacle Backplate

Options

Output Circuit Breakers

Output AC Waveform (AC Mode)

Optional SUPDM11 backplate adds 2 L6-30R outlets and L6-30P input cord

40A double-pole

Pure Sine wave

Output AC Waveform (Battery Mode) Pure Sine wave

2 / 6

INPUT

Rated input current (Maximum Load) 30A

Nominal Input Voltage(s) Supported 200V AC; 208V AC; 220V AC; 230V AC; 240V AC

UPS Input Connection Type Hardwire

UPS Input Connection Description

Supports North American 208/240V input (L1,L2,G) and International 230/220/240V (L,N,PE) input wiring; Optional

SUPDM11 backplate adds 2 L6-30R outlets and L6-30P input cord

Input Circuit Breakers

Recommended Electrical Service

Input Phase

40A double-pole

30A 208/220/230/240V

Single-Phase

BATTERY

Full Load Runtime (min.)

Half Load Runtime (min.)

Expandable Battery Runtime

External Battery Pack Compatibility

DC System Voltage (VDC)

Battery Recharge Rate (Included

Batteries)

Battery Replacement Description

8 min. (4200w)

20 min. (2100w)

Includes one non-expandable BP240V7RT3U (limit 1) external battery pack. No additional BP240V7RT3U external battery packs can be connected to the host UPS, beyond the one included with the SU6000RT3UHV UPS bundle.

All additional battery packs connected beyond the included BP240V7RT3U, must be BP240V10RT3U,

BP240V557C-1PH, BP240V787C-1PH, BP240V1037C-1PH or BP240V1407C-1PH

BP240V10RT3U; BP240V557C-1PH; BP240V787C-1PH; BP240V1037C-1PH; BP240V1407C-1PH

240

Less than 6 hours from 10% to 80% (typical, full load discharge)

Hot-swappable, user replaceable batteries

VOLTAGE REGULATION

Voltage Regulation Description

Overvoltage Correction

Undervoltage Correction

LEDS ALARMS & SWITCHES

LED Indicators

Front Panel LCD Display

Audible Alarm

Alarm Cancel Operation

Switches

Online, double-conversion power conditioning

2% output voltage regulation during overvoltages to 276

2% output voltage regulation during undervoltages to 156

6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options

Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options;

LED/LCD panel rotates for viewing in rack/tower formats (see manual)

Unique audible alarms for all major UPS, environmental and power conditions (see manual)

Alarm cancel switch

2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions

SURGE / NOISE SUPPRESSION

3 / 6

UPS AC Suppression Response

Time

EMI / RFI AC Noise Suppression

Instantaneous

Yes

PHYSICAL

Included Mounting Accessory

Description

2 sets of adjustable 4 post rack rails included (for UPS and battery pack components); 2-9USTAND tower kit included (supports up to 9U in tower format)

Installation Form Factors Supported with Optional Accessories

2 post rackmount (2POSTRMKITHD)

Optional Mounting Accessory Notes 2 sets of 2POSTRMKITWM required for 2 post rackmount installation of separate power module and battery pack

Primary Form Factor Rackmount

UPS Power Module Dimensions

(hwd, in.)

UPS Power Module Dimensions

(hwd, cm)

Installed Whole System Maximum

Rack Depth (in.)

5.2 x 17.5 x 26

13.3 x 44.4 x 66

26

Installed Whole System Maximum

Rack Depth (cm)

Rack Height (U Spaces)

UPS Power Module Weight (lbs.)

UPS Power Module Weight (kg)

UPS Dimensions Details

Stepdown Transformer Dimensions

(hwd / in.)

Stepdown Transformer Dimensions

(hwd / cm)

Included Battery Pack Dimensions

(hwd / in.)

66

6

43.8

19.9

Includes 3U power module and 3U battery pack

5.2 x 17.5 x 25

Included Battery Pack Dimensions

(hwd / cm)

Included Battery Pack Weight (lbs.)

Included Battery Pack Weight (kg)

13.3 x 44.4 x 63.5

136.5

62

UPS Shipping Dimensions (hwd / in.) 24.5 x 24 x 35

UPS Shipping Dimensions (hwd / cm)

62.2 x 61 x 88.9

Shipping Weight (lbs.)

Shipping Weight (kg)

Cooling Method

UPS Housing Material

323

146.6

Fan

Steel

4 / 6

ENVIRONMENTAL

Operating Temperature Range

Storage Temperature Range

Relative Humidity

AC Mode BTU / Hr. (Full Load)

AC Economy Mode BTU / Hr. (Full

Load)

AC Mode Efficiency Rating (100%

Load)

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.

+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.

0 to 95%, non-condensing

1412.3

911.5

91%

AC Economy Mode Efficiency Rating

(100% Load)

94%

Operating Elevation (ft.)

Audible Noise

0-3000m (0 to 10,000 ft.)

60 dBA at front side 1 meter

COMMUNICATIONS

Communications Interface DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface

Network Monitoring Port Description RS232 and contact closure communications are located on two separate DB9 ports

PowerAlert Software

Communications Cable

Included

DB9 cable included

LINE / BATTERY TRANSFER

Transfer Time

Transfer Time (Economy Mode)

Low Voltage Transfer to Battery

Power (Setpoint)

High Voltage Transfer to Battery

Power (Setpoint)

No transfer time (0 ms.) in online, double-conversion mode

Less than 1ms typical power failure response in optional economy mode

156

276

SPECIAL FEATURES

Cold Start (Startup in Battery Mode

During a Power Failure)

High Availability UPS Features

Green Energy-Saving Features

Cold-start operation supported

Automatic inverter bypass; Hot swappable batteries

High efficiency economy mode operation; Schedulable daily hours of economy mode operation

CERTIFICATIONS

UPS Certifications

Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); CE; Tested to GOST (Russia);

Tested to SASO (Saudi Arabia); Tested to IRAM (Argentina); Meets FCC Part 15 Category A (EMI); ROHS

(Restriction of Hazardous Substances)

WARRANTY

5 / 6

Product Warranty Period (Worldwide) 2-year limited warranty

© 2015 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous improvement.

Specifications are subject to change without notice. Photos may differ slightly from final products.

6 / 6