The EVD2-60IN is a 2 wire intercom system that allows you to communicate with visitors at your door. It includes features like hands-free communication, door release, video and picture recording, and intercom function. The EVD2-60IN can be connected to multiple slave monitors, as well as a guard unit monitor. It also has features like the Do Not Disturb function for privacy and the Divert function for transferring calls to another phone number. To use the device, you can mount the monitor and connect the system correctly according to the instructions in this manual. You can then communicate with visitors at your door, open the door, record video and pictures, and more.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
2 WIRE INTERCOM SYSTEM
EVD2-60IN
Please read this manual carefully before using the product, and keep it well.
ENGLISH
1. Parts and Functions
SD card
Digital TFT LCD Screen
Talk/MON Button
Menu Button
Unlock Button
Microphone
L1
L2
Mounting Hook
Connection Port
Speaker
-1-
Key functions
LCD screen
Unlock button
Display the visitors' image
Press to release the door
Menu button Press to open the menu shortcuts
Talk/Mon button Press to communicate hands free with visitor
Microphone
Mounting hook
Connection port
Speaker
Press to view the outdoor condition in standby mode
Receive voice from the user
Use to hang up the monitor
Bus terminal
Send out vioce from the visitor
DIP Settings
Bit
DIP1&2
Bit State
3
3
DIP3
3
Description
Reserved. left to default.
Set to OFF. When the monitor is in the middle of the line in daisy chain connection.
Set to ON. When the montior is at the end of the line or connected to a DBC4S.
2. Monitor Mounting
1. Use the screws to fix the Mounting Bracket on the mounting box.(fitting accesories includes a Bracket (Two pieces of 4X25 screws are needed to fasten the Mounting
Bracket), Special 2 wire connectors to connect with Monitor)
2. Wire the system correctly(refer to connection chapter) then hang the Monitor on the Mounting Bracket firmly.
3. Main Menu
Touch the touch button anywhere in standby mode, the main menu page will be shown as follows:
4. Basic Door Release Operation
1. Press CALL button on outdoor station, the
Monitor rings, at the same time, the screen displays the visitors' image.
It will display the call source string
00:30 Front Door
2. Press TALK/MON Button on monitor or touch icon on screen, you can communicate hands free with the visitor for
90 seconds.After finishing communication,press TALK/MON button again or touch icon to end the communication. If nobody answers the phone, the screen will be turned off automatically after 30 seconds.
-2-
3.
UNLOCK Button or touch door for the visitor.(if two locks are connected to door camera,touch unlock
2nd icon to release the second lock )
icon to open the
4.
can display the view of outside. Or touch Monitor icon on main menu to get into the door camera switching mode, if multi door stations are installed, you can press the door 1/2/3/4 to monitor the door station or CCTV camera you want.press
icon to exit and enter main menu page.
Note: if the system connect 2 wire camera via camera controller, press the camera
1/2/3/4 to monitor the camera you want.press icon to exit and enter main menu page.
5. Intercom Function
Touch
Intercom icon on main menu to get into the intercom mode , you have 4 item to select:Inner Broadcast, Inner Call, Name List Call and Call Guard Unit.
-3-
1.
Inner Broadcast
: If multi slave monitors are installed in the same apartment, select
Inner Broadcast, all the other monitors will mandatory receive broadcast content at the same time, whichever slave monitor doesn't need to answer the broadcast, and whichever slave monitor also doesn't need to open the scrccn.
2.
Inner Call
: If multi slave monitors are installed in the same apartment, select Inner
Call, all the other Monitors will ring at the same time, whichever Monitor answers the call, conversation is started.and the other monitors will stop ringing at the same time.
3.
Name List Call
: User in one apartment can call other apartments in the system.
Touch Name List Call icon (the namelist will be created automatically by the system) on intercom mode menu page, Select a name on the screen then touch
icon to call.Press / icon to enter last/next name list page. (Touch Dial
Number icon again to redial)
4.
5.
6.
7.
Name List
[ 01 ] Jim. Zhang
[ 02 ] Calo. Liu
[ 03 ] Jacko. Zhang
[ 04 ] Philips. Chen
[ 05 ] Hebe. Zhang
[ 06 ] Tony. Li
8.
4.
Call Guard Unit
: A Monitor can be assigned as Guard Unit Monitor; when the Guard
Unit Monitor answers the call, conversation with the guard person is started..
6. Video/Picture Memory
Note: The video/picture memory function is built into the monitor.
Video/Picture Recording
Both Auto-Recording and Manual-Recording are available.And Auto-Recording is default. If receive a call , after 3s, the monitor will record one video/picture for each calling automatically. Or you can touch icon to record the visitor's video/image manually when the monitor is in monitoring or calling.
Video/Picture Playback
Touch Playback icon on main menu, the recorded videos/pictures will be played on screen, please note that touch icon to Start/Pause the videos recorded.
-4-
-5-
Image:008/020 2014/06/23 14:36:55
Note: When the system without SD card: 1.118 pictures in inner memory
2.Manage each picture.
When the system with SD card:1.A brand new SD card needs to be formated
by the monitor, then can it be used for video recording.
2.Up to 32G Micro SD card.
3.Video & Audio record.
4.Manage each video clips.
5.Can be copied.
7. Call Record Function
Call Record:All the calls concerning the montior, including Door-station-to-monitor call, monitor-to-monitor call, will be recored and can be reviewed afterwards.
Touch Call Record icon on main menu to get into the call record mode.When there are unread call records, arrow color red. Press the unread call record, and then touch icon to play it.
Call Record
01/05
06-23 15:22 Calo.Liu
06-18 20:54 Smith
06-12 11:06 Vincent.Yang
05-29 08:39 Allen.Chen
05-27 21:43 Hebe.Zhang
04-20 13:16 Ben.Wu
Note: 1.Automatic limited number of records.
2.Do not need to delete any a record.
Call Record
01/05
06-23 15:22 Calo.Liu
06-18 20:54 Smith
06-12 11:06 Vincent.Yang
05-29 08:39 Allen.Chen
05-27 21:43 Hebe.Zhang
04-20 13:16 Ben.Wu
8. Do Not Disturb Function
Touch
Do Not Disturb
icon on main menu to get into the don't disturb mode , you have 4 item to select:Normal, For 1 Hour, For 8 Hours and Always. You can select the appropriate item according to your needs.
Do Not Disturb
Normal
For 1 Hour
For 8 Hours
Always
Refuse Call In: 00:58:32
Note: When you select "For 1 Hour" or "For 8 Hours", bottom of the screen will display the remaining time.
9. Divert Function
Touch
Divert
icon on main menu to get into the transfer mode. Touch the empty place ,and then input the telephone number by pressing the digital keypad.And it has 3 types of divert modes:
1:Don't Transfer----calls from outdoor station will not be diverted.
2:If No Answer----outdoor station calls indoor monitor firstly,if nobody answer the call within 30 seconds,the call will be diverted to the telephone number you set. At this mode,the monitor will shut off immediately when TPC/GSM/
TPS divert sucessfully,while it won't affect the communication between TPC/
GSM/TPS and outdoor station.Otherwise, the monitor can do the operation of monitoring,talking,and unlocking.
3:Simutaneously----calls from outdoor station will be diverted to your telephone immediately.At this mode,the monitor won't shut off when TPC/GSM/TPS divert sucessfully,but if the monitor answers the call at this time,TPC/GSM/TPS will quit absolutely.
Transfer Options
Don't Transfer
If No Answer
Simutaneously
1)
2)
3)
-6-
Note:1.Touch icon to detect the transfer device info.
2.Touch icon to send message.
Transfer Options
Don't Transfer
If No Answer
Simutaneously
1)
2)
3)
Transfer Device Info
Device -
SIM -
Network -
Signal Level -
10. Staircase Light
Note: the staircase light function will be activated only when the system connect light via SC6V module, otherwise, this function is unvalid in normal. For more information, please refer to SC6V user instruction in detail.
On main menu page or in monitoring,touch Light icon to open the staircase light, the staircase light will be turned off automatically.
11. Basic Setup Instructions
Sounds Settings
Touch icon on main menu page(or on door camera switching mode page), then select
"Sounds" item to enter the sounds settings page.You can set a variety of ring tones on this page.(touch icon to exit the setting and return main menu page.
-7-
Note: Door Ring have 2 mode:United and Seperate.If select "United",it means
Door1/2/3/4 as a whole to adjust the ring tones.
Date & Time Settings
"
Touch icon on main menu page(or on door camera switching mode page), then select
Date & Time
" item to enter the date & time settings page.You can set the date & time on this page.(touch icon to exit the setting and return main menu page.
Note: You can set your own time, you can also synchronize the system time.
Rename & Monitor Time Settings
"
Touch icon on main menu page(or on door camera switching mode page), then select
More...
" item to enter the Rename & monitor time settings page.You can set door station rename, camera rename, monitor time on this page.(touch icon to exit the setting and return main menu page.
-8-
Note: If you want to rename, please touch the place of name, then it will turn keypad page ,you can input your new name in this page.
DS-3_
DOOR3 RENAME abc
-9-
Screen and Volume Adjustment
During monitoring or talking state, touch icon,the Adjust page will be displayed.
1. The Scene mode selection: Total 4 screen modes can be selected in sequence:
Normal,
Brightly, Soft
Brightness
User
and
User.
Whenever you modify
or
colour, Scene
item will be set to
mode automatically.
2. Note that all the modifications will be performed immediately after the operation.
Touch the window of image to exit the adjust page.
12. Restore to Default
The restore to default function allows the user to recover the settings to factory setting.
Note that the restore to default operation will not change the setting and datas.
Enter main menu page,and touch icon, then select "About" item (or touch logo position) to enter the about settings page, touch icon, the default settings will be loaded. touch icon to enter the Memo Information page, touch and icon to copy the pictures to SD card. Touch and icon to format SD card and restart.
About
Local Address 00.00
Video Standard AUTO
System Verson 00.01.00
Display Driver 1.0
Front 1.0
UI 1.0
Format SD Card And Restart ?
Memo Information
SD Card --
Video Capacity ----
Video Usage ----
Flash
Image Capacity 0118
Image Usage 0000
Copy Pictures To SD ?
Memo Information
SD Card --
Video Capacity
----
Video Usage ----
Flash
Image Capacity 0118
Image Usage 0000
13. Monitor Parameter Setting
How to enter the installation setting page
1.Touch icon on main menu page.
About
Local Address 00.00
Video Standard AUTO
System Verson 00.01.00
Display Driver 1.0
Front 1.0
UI 1.0
2.Touch UNLOCK button and hold for 2s.
_
INSTALLER SETUP
123
3.A digital keypad will be shown.
How to set the monitor as a Guard Monitor
A Monitor can be assigned as Guard Unit Monitor; when the Guard Unit Monitor answers the call, conversation with the guard person is started..
The code number of 8004 is used to set the monitor as a guard unit monitor and 8005 is used to cancel this function.
-10-
How to set the slave monitor address
Maximum 4 monitors can be connected in one apartment,one master monitor together with 3 slave monitors, so you should set the address correctly.(note:must have one monitor to be set as master monitor)
The code of 8000 is used to set the master monitor.
The code of 8001 is used to set the first slave monitor .
The code of 8002 is used to set the second slave monitor .
The code of 8003 is used to set the third slave monitor .
-11-
How to set date and time format
The system offers two methods of date and time.
The code number of 8008 is used to set the date format as month/date/year
The code number of 8009 is used to set the date format as date/month/year
The code number of 8012 is used to set the time format as 12 hour system
The code number of 8013 is used to set the time format as 24 hour system
How to set the monitor panel on
In default mode,when receive a calling,the master and slave monitors will ring at the same time,and just the master monitor can display the image while the slave monitors can not.But the settings can be changed,you can set the master monitor and all the slave monitors to panel on at the same time when receiving a call, just input the code number of 8006 on each slave monitor.
How to set the unlock parameter
Unlock mode:
There are two unlock modes: 1.power-on- to-unlock type:unlock mode=0(by default)
2.power-off-to-unlock:unlock mode=1.
The code number of 8010 is used to set the unlock mode to 0
The code number of 8011 is used to set the unlock mode to 1
Unlock time:
The unlock time can be changed by yourself at any time. it can be set from 1 to 99 seconds.
The code number from 8401 to 8499 are used to set the unlock time to 1~ 99 seconds.
How to set the user code for the monitor
Each monitor should be assigned an address in the system, total 32 addresses can be configured, the code number of 8200 to 8231 is used to controlled the address of 00 to
31. Please refer to the following table.
Input No.
8204
8205
8206
8207
8208
8209
8210
8200
8201
8202
8203
User Code
Code=0
Code=1
Code=2
Code=3
Code=4
Code=5
Code=6
Code=7
Code=8
Code=9
Code=10
Input No.
8215
8216
8217
8218
8219
8220
8221
8211
8212
8213
8214
User Code Input No.
User Code
Code=11
Code=12
Code=13
Code=14
Code=15
Code=16
Code=17
Code=18
Code=19
Code=20
Code=21
8222
8223
8224
8225
8226
8227
8228
8229
8230
8231
Code=22
Code=23
Code=24
Code=25
Code=26
Code=27
Code=28
Code=29
Code=30
Code=31
-12-
-13-
14. Specification
●
●
●
●
DC●20~28V●
●
●● Standby●12.4mA;●Working●270mA
7●Inch●digital●color●LCD
800*3(R,●G,●B)●x●480●pixels
1Vp-p,●75Ω,●CCIR●standard
2●wires,●non-polarity
139(H)×212(W)×15(D)mm
15. Precautions
1) All components should be protected from violence vibration. And not allow to be impacted, knocked and dropped.
2) Please do the cleanness with soft cotton cloth, please do not use the organic impregnant or chemical clean agent. If necessary, please use a little pure water or dilute soap water to clean the dust.
3) Image distortion may occur if the video monitor is mounted too close to magnetic field e. g. Microwaves, TV, computer etc.
4) Please keep away the monitor from wet, high temperature, dust, caustic and oxidation gas in order to avoid any unpredictable damage.
5) Must use the right adaptor which is supplied by the manufacturer or approved by the manufacturer.
6) Pay attention to the high voltage inside the products, please refer service only to a trained and qualified professional.
Note
-14-
2 WIRE INTERCOM SYSTEM
EVD2-60IN
The design and specifications can be changed without notice to the user. Right to interpret and copyright of this manual are preserved.
advertisement
Key Features
- Hands-free communication
- Door release
- Video and picture memory
- Intercom function
- Do Not Disturb function
- Divert function
- Staircase light
- Multiple slave monitor support
- Guard unit monitor support
- Call record function