Genius in one Design

Add to my manuals
8 Pages

advertisement

Genius in one Design | Manualzz
Fully Flat Casset te
Design
& Genius
in
one
Fully
Flat
Cassette
Design and
genius in one
As a market-leader Daikin again shows
the way with the launch of yet another
world-class cassette that delivers superior
design with high performance and low
energy consumption, providing the ideal
solution for offices, banks and retailers.
The fully flat cassette integrates the latest
technology with energy saving functions
that enhance user comfort, all within a
unique design that allows the visible panel
to fit flush within standard architectural
ceiling panels.
Fully integrated,
fully discreet
The concept our designers, from the renowned design agency
yellow design, had in mind was meeting the demanding
criteria of architects on design. The fully flat cassette is a
unique iconic design with an elegant white finish with an
optional silver or white decoration panel. The cassette blends
in, resulting in a fully discreet unit.
2
Fully flat with the ceiling
The fully flat cassette is the first cassette that fits fully flat with the
ceiling, making the unit blend discreetly in the ceiling.
Fits architectural ceiling tiles perfectly
The fully flat cassette fits flush in standard European architectural
ceiling tiles. The newly designed panel integrates fully within one
ceiling tile enabling lights, speakers and sprinklers to be in stalled
in the adjoining ceiling tiles.
3
Differentiated
by excellence
Sensor-driven comfort
To ensure perfect comfort the fully flat cassette is fitted
with two optional sensors linked to an advanced controller.
When there is nobody in the room, the presence sensor adjusts
the set point or switches off the unit, avoiding unneccesary
cooling or heating, thus saving energy. When motion is detected
the temperature is reset to its original setpoint ensuring perfect
working conditions at all time.
The sensor also adapts the direction of the airflow depending
of where people are situated in the room, ensuring no draught
and every individual’s comfort at any time.
Because hot air rises, the natural temperature distribution in a room
is for it to be warmer near the ceiling and cooler near the floor. The
cassette’s ‘floor’ sensor detects the temperature difference and
re-directs the airflow to ensure that the temperature distribution is
even: cold feet are history!
Flexible solution
The need for flexible usage of space often means that temporary
or permanent barriers are erected leaving the cassette close to
a wall or in a corner with the resulting imbalances in airflow.
Our advanced technology anticipates this and we have made it
possible to use the controller to individually open or close one
of the four flaps to restore optimal efficiency and to save on
energy costs.
4
Top efficiency
year-round
Silent comfort
The fully flat cassette is the quietest unit in the light
commercial market and, in addition to the sensors,
has various functions that are designed to enhance
the user’s comfort and pleasure.
As with all Daikin products, this cassette
delivers exceptional seasonal efficiency while
Air quality
The quality of the air in the room is as important as
the presence sensor has been shown to reduce
energy consumption by around 27%*.
the temperature and we have fitted advanced filters
to remove dust particles to ensure the air is clean. In
addition, a special programme allows the humidity
levels to be reduced without variations in temperature.
*estimated
Intuitive control
The fully flat cassette’s advanced controller provides the
user with absolute control over their work environment.
The large display screen and on-screen instructions
combined with clearly marked function buttons allow
users to quickly set their desired conditions and to focus
on the job at hand.
5
Inverter
Energy saving during
standby mode
Weekly timer
Infrared remote
control
Home leave
operation
Wired remote
control
Fan only
Draught
prevention
Powerful mode
Auto coolingheating changeover
Whisper quiet
Outdoor unit
silent operation
Auto-restart
Self diagnosis
Drain pump kit
Twin/triple/double
twin application
FFQ-C
Multi model
application
FFQ-C
Super Multi Plus
FFQ-C
Ceiling soiling
prevention
Vertical auto
swing
Fan speed steps
Dry programme
Replacement
technology
white panel
silver and white panel
Heating & Cooling
Perfect for light commercial pair applications
INDOOR UNIT
Cooling capacity
Heating capacity
Nom.
Nom.
Cooling
Seasonal efficiency
(according to
EN14825)
Heating
(Average
climate)
kW
kW
Energy label
Pdesign
SEER
Annual energy consumption
Energy label
Pdesign
SCOP
Annual energy consumption
EER
COP
Annual energy consumption
Cooling
Energy label
Heating
Material
Unit
HeightxWidthxDepth
Unit
Model
Colour
Decoration panel
Dimensions
HeightxWidthxDepth
Weight
Cooling
High/Nom./Low
Fan - Air flow rate
Heating
High/Nom./Low
High
Sound power level Cooling
Cooling
High/Nom./Low
Sound pressure
Heating
High/Nom./Low
level
Liquid
OD
OD
Piping connections Gas
Drain
OD
Power supply
Phase / Frequency / Voltage
Nominal efficiency
(cooling at 35°/27°
nominal load,
heating at 7°/20°
nominal load)
Casing
Dimensions
Weight
kW
kWh
FFQ25C
2.50
3.20
A
2.50
5.25
167
FFQ35C
3.40
4.20
2.31
4.12
784
4.46
3.81
280
3.45
4.09
1,182
3.70
3.41
460
3.40
5.60
212
FFQ50C
5.00
5.80
A+
5.00
5.70
307
FFQ60C
5.70
7.00
3.84
4.10
1,311
3.21
3.49
780
3.96
4.17
1,329
3.02
3.41
945
5.70
5.60
356
A+
kW
kWh
kWh
A
A
Galvanised steel plate
260x575x575
mm
kg
mm
kg
m³/min
m³/min
dBA
dBA
dBA
mm
mm
mm
Hz / V
16
17.5
BYFQ60CW / BYFQ60CS / BYFQ60B2
White (N9.5) /White (N9.5) + Silver / White (RAL9010)
46x620x620 /620x46x620 /55x700x700
2.8 / 2.8 / 2.7
10/8.5/6.5
12/10/7.5
10/8.5/6.5
12/10/7.5
51
56
34/30.5/25
39/34/27
34/30.5/25
39/34/27
6.35
9/8/6.5
9/8/6.5
48
31/28.5/25
31/28.5/25
9.52
14.5/12.5/9.5
14.5/12.5/9.5
60
43/40/32
43/40/32
12.7
1~ / 50 / 220-240
(1) EER/COP according to Eurovent 2012 (2) Dimensions do not include control box (3) The sound power level is an absolute value indicating the power which a sound source generates.
OUTDOOR UNIT
Dimensions
Weight
Compressor
Sound power level
Sound pressure
level
Unit
HeightxWidthxDepth
Unit
Type
Cooling
Nom./High
Cooling
High/Silent operation
Heating
High/Silent operation
Cooling
Ambient
Min.~Max.
Operation range
Heating
Ambient
Min.~Max.
Type
Refrigerant
GWP
Liquid
OD
Gas
OD
OD
Piping connections Drain
Piping length
OU - IU
Max.
Level difference IU - OU
Max.
Phase / Frequency / Voltage
Power supply
8
RXS25K
mm
kg
dBA
dBA
dBA
°CDB
°CWB
mm
mm
mm
m
m
Hz / V
RXS35K
550x765x285
34
62/46/43
47/44
9.5
Air filter
RXS50K
735x825x300
47
Hermetically sealed swing compressor
-/63
48/44
48/45
-10~46
-15~18
R-410A
1,975
6.35
12.7
18.0
20
15
RXS60F
735x825x300
48
63
49/46
49/46
-15~20
R-410A
30
20
1~ / 50 / 220-240
Twin, triple, double twin
•
•
OUTDOOR UNIT
RZQG71L8V1
RZQG100L8V1
Seasonal Smart RZQG125L8V1
RZQG140L7V1
For long or irregularly shaped rooms you can use up to four indoor units powered by a
single outdoor unit.
All indoor units are controlled at the same time.
• operation in heating mode
down to -20°C
• 75m pipe run
• Compatibility with D-BACS
RZQG71L8Y1
RZQG100L8Y1
RZQG125L8Y1
RZQG140LY1
RZQ200C
RZQ250C
RZQSG71L3V1
RZQSG100L8V1
RZQSG125L8V1
RZQSG140LV1
RZQSG100L8Y1
RZQSG125L8Y1
RZQSG140LY1
Multi model application
•
•
FFQ-C
50
35
2
3
4
4
• operation in heating mode
down to -15°C
• 100m pipe run
-
• operation in heating mode
down to -15°C
• 50m pipe run
• Compatibility with D-BACS
2
3
4
4
60
2
3
3
2
4
3
-
4
2
3
3
2
A single multi outdoor unit can power up nine indoor units in different rooms. Of course, the
climate of each room is individually controlled.
This assures top efficiency and optimum comfort for each separate space.
OUTDOOR UNIT
2MXS50H
3MXS40K
3MXS52E
3MXS68G
4MXS68F
4MXS80E
5MXS90E
RXYSQ-P8V1
25
35
50
●
●
●
60
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Heating & Cooling, Heat Recovery
Fully integrated solutions for medium to large commercial environments connecting up to 64 indoor units to a single
system, all individually controlled.
•
•
•
Perfect comfort by simultaneous heating spaces, while cooling others
Free heating of rooms or water possible by heat recovery
Temperature control, fresh air, air curtains and hot water production all integrated in a single system
INDOOR UNIT
Cooling capacity
Heating capacity
Nom.
Nom.
Cooling
Nom.
Power input - 50Hz
Heating
Nom.
Unit
HeightxWidthxDepth
Dimensions
Unit
Weight
Model
Colour
Decoration panel
Dimensions
HeightxWidthxDepth
Weight
High/Nom./Low
Fan-Air flow rate Cooling
- 50Hz
Heating
High/Nom./Low
High/Nom.
Sound power level Cooling
Cooling
High/Nom./Low
Sound pressure
level
Heating
High/Nom./Low
Type
Refrigerant
Piping connections Liquid/OD/Gas/OD/Drain
Phase/Frequency/Voltage
Power supply
Current - 50Hz
Maximum fuse amps (MFA)
kW
kW
kW
kW
mm
kg
mm
kg
m³/min
m³/min
dBA
dBA
dBA
mm
Hz/V
A
FXZQ15A
1.7
1.9
FXZQ20A
2.2
2.5
0.043
0.036
15.5
FXZQ25A
2.8
3.2
FXZQ32A
3.6
4.0
0.045
0.038
260x575x575
FXZQ40A
4.5
5.0
0.059
0.053
16.5
BYFQ60CW / BYFQ60CS / BYFQ60B2
White (N9.5) / White (N9.5) + Silver / White (RAL9010)
46x620x620 / 46x620x620 / 55x700x700
2.8 / 2.8 / 2.7
8.5/7/6.5
8.7/7.5/6.5
9/8/6.5
10/8.5/7
11.5/9.5/8
8.5/7/6.5
8.7/7.5/6.5
9/8/6.5
10/8.5/7
11.5/9.5/8
49/50/51/54/31.5/28/25.5
32/29.5/25.5
33/30/25.5
33.5/30/26
37/32/28
31.5/28/25.5
32/29.5/25.5
33/30/25.5
33.5/30/26
37/32/28
R-410A
6.35/12.7/VP20 (I.D. 20/O.D. 26)
1~/50/220-240
16
FXZQ50A
5.6
6.3
0.092
0.086
18.5
14.5/12.5/10
14.5/12.5/10
60/43/40/33
43/40/33
For more information on combination, please refer to the VRV catalogue.
7
Design
& Genius
in
one
Europe’s new energy label:
raising the bar on energy efficiency
To realise its challenging 20-20-20 environmental goals, Europe is imposing minimum efficiency
requirements for energy related projects. These minimum requirements come into effect on 1 January
2013, and will be revised upward in subsequent years.
Not only does the Eco-Design Directive systematically raise the minimum requirements with respect to
environmental performance, the method used to measure this performance has also been changed to
better reflect real-life conditions. The new seasonal performance rating provides a much more accurate
picture of actual expected energy efficiency over an entire heating or cooling season.
Completing the picture is a new energy label for EU. The present label, introduced in 1992 and
modified in the meantime, allows consumers to compare and make purchasing decisions based on
uniform labelling criteria. The new label includes multiple classifications from A+++ to D reflected in
colour shadings ranging from dark green (most energy efficient) to red (least efficient). Information
on the new label includes not only the new seasonal efficiency ratings for heating (SCOP) and
cooling (SEER), but also annual energy consumption and sound levels. It will allow end-users to
make even better informed choices, since seasonal efficiency reflects air conditioner or heat pump
The present leaflet is drawn up by way of information only and does not
constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has
compiled the content of this leaflet to the best of its knowledge. No express or
implied warranty is given for the completeness, accuracy, reliability or fitness
for particular purpose of its content and the products and services presented
therein. Specifications are subject to change without prior notice. Daikin Europe
N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest
sense, arising from or related to the use and/or interpretation of this leaflet. All
content is copyrighted by Daikin Europe N.V.
Daikin Europe N.V. participates in the Eurovent
Certification programme for Air conditioners (AC),
Liquid Chilling Packages (LCP), Air handling units
(AHU) and Fan coil units (FCU), Check ongoing validity
of certificate online: www.eurovent-certification.com
or using: www.certiflash.com”
Daikin products are distributed by:
FSC
ECPEN13-107
Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende
ECPEN13-107 • XXX • 04/ 13 • Copyright Daikin
Printed on non-chlorinated paper. Prepared by La Movida, Belgium
Resp. Ed.: Daikin Europe N.V., Zandvoordestraat 300, B-8400 Oostende
efficiency over an entire season.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement