Logo Projector
.
TABLE OF CONTENTS
1. Introduction
2. Safety Instruction
3.Description
4.Operation and Technical Specification
5.Lamp Installation or Replacement
6.Inserting/Exchanging Rotating Gobos
7.Beam Angle
8. Stand-alone Operation
9. Troubleshooting
10. Fixture Cleaning
User Guide for Logo Projector
Professional Entertainment Technology
Широкий ассортимент оборудования ACME
на www.maxlight.ru
1-
♦
1. Introduction
In the event of serious operating problem, stop using the unit immediately. Never try to
repair the unit by yourself. Repairs by unskilled people can lead to damage or
Thank you for purchasing Wild Tech’s Logo Projector. The fixture is a powerful tool creating
malfunction. Please contact the nearest authorized technical assistance center.
a long lasting visual effect. It comes with 7 D size gobos and an inter-changeable slot for
Always use the same type spare parts.
custom-made gobos. With speed and direction adjustable function, the Logo projector is
♦
Don’t connect the device to any dimmer pack or power pack.
perfect for discos, restaurants, department stores, etc.
♦
Do not touch any wire during operation as high voltage might be causing electric
shock.
.
2. Safety Instruction
Warning
Please read the instruction carefully which includes important
information about the installation, usage and maintenance.
♦
To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or
moisture.
WARNING
♦
Never touch bulb with bare fingers as it is very hot after using.
♦
Please keep this user guide for future consultation. If you sell the unit to another user,
♦
Hot lamp explosion hazard. Do not open the unit within five minutes after switching off.
please be sure they also receive this instruction booklet.
♦
Do not start on the unit without bulb enclosure or housing is damaged.
Unpack and check carefully about there is no transportation damage before using the
♦
The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly
♦
damaged.
unit.
♦
Before operating, ensure that the voltage and frequency of power supply match the
♦
Do not look directly at the light while the bulb is on.
power requirements of the unit.
♦
It’s important to ground the yellow/green conductor to earth in order to avoiding electric
Caution
There are no user serviceable parts inside the unit. Do not open the housing or attempt
shock.
♦
For indoor use only and only in a dry location.
♦
The unit must be installed in a location with adequate ventilation, at least 50cm from
adjacent surfaces. Be sure that no ventilation slots are blocked.
any repairs yourself. If the unit requires service, please contact your nearest dealer.
Rigging the fixtures
The unit should be mounted via its screw holes on the bracket. Always ensure that the
♦
Disconnect mains power before fuse/lamp replacement or servicing.
♦
Replace fuse/lamp with the same type only.
unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the
♦
Make sure there are no flammable materials close to the unit as it is fire hazard.
structure to which you are attaching the unit is secure and is able to support a weight of 10
♦
Use safety cable when fixes this unit.
times of the unit’s weight. Also always use a safety cable that can hold 12 times of the
♦
Maximum ambient temperature is TA: 40℃. Don’t operate it where the temperature is
weight of the unit when installing the fixture.
higher than this.
The installation must be carried out by qualified service people only. The device should be
Surface temperature may reach up to 85℃ during operating. Don’t touch the housing
installed out of reach of people and outside areas where persons may walk by or be seated.
♦
barehanded during its operation. Turn off the power and allow about 15 minutes for the
unit to cooling down before replacing bulb or serving.
2-
3-
5. Lamp installation or replacement
3. Description
• Always switch off the mains supply and never handle the lamp or luminarie when it is hot.
• Do not touch the bulb with bare hands. If it happen, clean the lamp with denatured alcohol
and wipe with a lint free cloth before installing.
1. Optical lens: Manual focus adjustment.
2. Hanging bracket: with 2 knobs on both sides to fasten the unit and a mounting hole to fix
6. Inserting/Exchanging rotating gobos
a mounting hook.
3. Mains input:IEC socket and integrated fuse holder, connect to main power cable.
4. Cooling fan: Cool down the working temperature.
5. Dip switches:Enable stand-alone model:
Pin 10 is ON: Pin 9 for motor direction & pins 1~8 for speed adjustable
Pin 10 is OFF: The unit stops rotating.
4. Operation and Technical Specification
• Plugging into the mains power, the fixture starts running. The Logo Projector runs in
automatic mode.
Gobo list:
• Adjustable gobo rotation direction and speed by dip switches.
7. Beam angle
• Focus adjustable and fan cooled.
Specification:
• Voltage: AC 120V~60Hz 230V/240V/250V~50Hz/60Hz
• Fuse: 20mm glass 250V T6.3A / 20mm glass 250V T5A
• Bulb: EHJ 24V 250W
• Dimension: 306 x 263 x 140 mm
• Weight: 8.2 kgs
The Projector is best to be placed 5 meters from wall, and from this distance the light
effect will cover an area of 2.1 m x 2.1 m.
4-
5-
8 . Stand-Alone Operation
10. Fixture Cleaning
Enable stand-alone model: Pin 10 is ON: Pin 9 for motor direction & pins 1~8 for speed
adjustable
The cleaning of internal and external optical lenses and/or mirrors must be carried out
periodically to optimize light output. Cleaning frequency depends on the environment in
which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater
accumulation of dirt on the unit’s optics.
y
Clean with soft cloth using normal glass cleaning fluid.
y
Always dry the parts carefully.
y
Clean the external optics at least every 20 days. Clean the internal optics at least every
30/60 days.
EC Declaration of Conformity
We declare that our products (lighting equipments) comply with the following
specification and bears CE mark in accordance with the provision of the
Electromagnetic Compatibility (EMC) Directive 89/336/EEC.
9. Troubleshooting
EN55014-2: 1997 A1:2001, EN61000-4-2: 1995; EN61000-4-3:2002;
EN61000-4-4: 1995; EN61000-4-5: 1995, EN61000-4-6:1996,
Problem
Probable cause(s)
Suggested remedy
No power to the fixture
Check power connections
EN61000-4-11: 1994.
&
Harmonized Standard
If power is applied but does not light,
Blown fuse
No light
please check and replace fuse if
EN60598-1: 2000+ALL:2000+A12:2002
necessary.
Safety of household and similar electrical appliances
Part 1 : General requirements
Burned out lamp
Install new lamp.
Allow to cool down. Improve air flow
Fixture too hot
around the unit.
Sound too low to activate
No action
control circuit
Electrical malfunction
Increase volume.
Refer to service technician.
6-
Innovation , Quality , Performance
7-
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF