Programming new ID
CONTENT IS SUBJECT TO CHANGE WITHOUT NOTICE
ID EXIT
PANEL
Door is alarming
(Flashing Red)
Secure Care Products, ®Inc.
Door is armed (Red)
LED will turn off when escort
code is entered.
ID
Fire is activated
(Flashing Red)
Panel is ON
(Green)
Transmitter is within range of
panel (Red)
Transmitter is being
detected (Flashing
Yellow)
1
2
3
4
5
6
7
8
9
*
0
#
If two transmitters are
present, center light is solid. If
three or more transmitters are
present, center light will blink.
Keypad punch indicator
(lights when any key is
pressed)
SECTION 9 PROGRAMMING
NOTE: The PM mode must be disabled to make any
programming changes to the Exit Panel. Refer to PM
Programming in this section of the manual.
NOTE: All programming is stored in non-volatile memory. This
means that if the panel loses power, the programming will remain
in memory.
Reset Escort Codes
To reset the panel to factory settings: Enter *309 *9876543214
Each ID Exit Panel offers three separate four digit codes for escorting transmitters legally through a
protected doorway or hallway, or resetting an alarm condition created by the presence of a transmitter
while the exit door is open or hallway perimeter is breached. These three codes are referred to as the
Primary, Secondary, and Tertiary. The Primary and Tertiary codes allow for resetting alarm
conditions and escorting transmitters through protected areas when the Advanced Security Mode is
not used (refer to programming the Advanced Security Mode for more operation details of that
feature). The Secondary code allows for resetting, escorting, and programming in all conditions. This
code allows transmitters to be escorted through a protected area while Advanced Security Mode is
active.
Primary Code (any three digits proceeded by *).
Factory Default - *234
To change the Primary code, follow the three listed steps without pausing for greater than one second
between keystrokes.
1. Enter *567 or currently programmed Secondary code
2. Enter *9876543210#
3. Enter new three digit code.
• One confirmation beep = Change Accepted
Factory Default - *567
Secondary Code (any three digits preceded by *)
To change the Secondary code, follow the three listed steps without pausing for greater than one
second between keystrokes. Once the Secondary code is changed this new number becomes
the new programming code.
1.
2.
3.
Enter *567 or currently programmed Secondary code
Enter *9876543211#
Enter new three digit code.
• Two confirmation beeps = Change Accepted
NOTE: To Default Secondary code only
Tertiary Code (any three digits proceeded by *).
Enter *309*9876543212
Factory Default - *751
To change the Tertiary code, follow the three listed steps without pausing for greater than one second
between keystrokes.
1. Enter *567 or currently programmed Secondary code
2. Enter *9876543212#
3. Enter new three digit code.
• Three confirmation beeps = Change Accepted
SECTION 9 PROGRAMMING
Escort Time
Each Exit Panel has a time period that allows passing through a door without creating an alarm. The
factory default escort time is thirty (30) seconds.
Escort Time
Factory Default 30 Seconds
To change the Escort time, follow the three listed steps without pausing for greater than one second
between keystrokes.
1. Enter *567 or currently programmed secondary code
2. Enter *9876543215#
3. Enter new three digit time in seconds (up to a maximum of 900 seconds but not less then
15 seconds) Example: 60 seconds = 060, 90 seconds = 090, 120 seconds = 120
4. Two confirmation beeps = Change Accepted;
5. One confirmation beep = Change Not Accepted
Delayed Egress Release Time
Each Exit Panel controlling an electromagnetic lock has a required time period for pressure applied to
a door to release the locking feature as required by NFPA 101. Refer to the NFPA 101 Life Safety
Code or your local Fire Marshall/Safety Inspector for guidance on local requirements.
Delayed Egress Release Time
Factory Default
15 Seconds
To change the release time from 15 to 30 seconds, follow the three listed steps without pausing for
greater than one second between keystrokes.
1. Enter *567 or currently programmed secondary code
2. Enter *9876543217#030
a. Multiple confirmation beeps = change accepted
b. One confirmation beep = change not accepted
To change the release time from 30 to 15 seconds, follow the three listed steps without pausing for
greater than one second between keystrokes.
1. Enter *567 or currently programmed secondary code
2. Enter *9876543217#015
a. Multiple confirmation beeps = change accepted
b. One confirmation beep = change not accepted
SECTION 9 PROGRAMMING
Delayed Egress Activation Time
Each Exit Panel controlling an electromagnetic lock has a required time period for pressure applied to
a door to activate the delayed egress release feature as required by NFPA 101. Refer to the NFPA
101 Life Safety Code or your local Fire Marshall/Safety Inspector for guidance on local requirements.
This feature allows you to modify the time necessary to apply the constant even pressure upon the
door to activate the delayed egress alarm mode. The four options below are 3 sec., 2 sec., 1 sec., and 0
sec. Changing the activation time from factory default should be done only after permission is
granted by the local authority having jurisdiction.
Delayed Egress Activation Time
Factory Default 3 Seconds
To change the activation time to 3 seconds, follow the three listed steps without pausing for greater
than one second between keystrokes.
1. Enter *567 or currently programmed secondary code
2. Enter *9876543217#753
a. Three confirmation beeps = change accepted
b. No confirmation beep = change not accepted
To change the activation time to 2 seconds, follow the three listed steps without pausing for greater
than one second between keystrokes.
1. Enter *567 or currently programmed secondary code
2. Enter *9876543217#852
a. Two confirmation beeps = change accepted
b. No confirmation beep = change not accepted
To change the activation time to 1 second, follow the three listed steps without pausing for greater
than one second between keystrokes.
1. Enter *567 or currently programmed secondary code
2. Enter *9876543217#951
a. One confirmation beep = change accepted
b. No confirmation beep = change not accepted
To change the activation time to 0 seconds, follow the three listed steps without pausing for greater
than one second between keystrokes.
1. Enter *567 or currently programmed secondary code
2. Enter *9876543217#580
a. Four confirmation beeps = change accepted
b. No confirmation beep = change not accepted
SECTION 9 PROGRAMMING
Latching Delayed Egress
Each Exit Panel controlling an electromagnetic lock has a required time period for pressure applied to
a door to release the locking feature as required by NFPA 101. This feature, when enabled, allows the
door to remain unlocked once the delayed egress feature is activated until an authorized reset code is
entered into the Exit Panel.
Latching Delayed Egress
Factory Default
Disabled
To enable the latching delayed egress feature, follow the three listed steps without pausing for greater
than one second between keystrokes.
1. Enter *567 or currently programmed secondary code
2. Enter *9876543217#999
• Four confirmation beeps = change accepted
To disable the latching delayed egress feature, follow the three listed steps without pausing for greater
than one second between keystrokes.
1. Enter *567 or currently programmed secondary code
2. Enter *9876543217#909
3. Three confirmation beeps = change accepted
Irreversible Latching Delayed Egress
The Exit Panel has a irreversible latching delayed egress. When enabled, this feature will, in the presence of a
transmitter and the activation of the nuisance alarm, unlock the door and keep it unlocked with an audible alarm until a
reset code is entered. Once the delayed egress cycle has been activated, the door will not reset itself even if the
transmitter is taken out of the detection range.
Irrevocable Latching Delayed Egress
Factory Default Disabled
To enable the irrevocable latching delayed egress, follow the three listed steps without pausing for
greater than one second between keystrokes.
1. Enter*567 or currently programmed secondary code
2. Enter*9876543217#888
• Four confirmation beeps = enabled
To disable the irrevocable latching delayed egress, follow the three listed steps without pausing for
greater than one second between keystrokes
1. Enter*567 or currently programmed secondary code
2. Enter*9876543217#808
• Three confirmation beeps = disabled
SECTION 9 PROGRAMMING
Fire Alarm Input Selection
Fire Alarm Input
Factory Default Normally Open
To change the fire alarm input between normally open and normally closed:
Normally Closed fire alarm contact active (looking for a closure from the Fire Alarm Relay to unlock
doors)
1. Enter *567 or currently programmed secondary code
2. Enter *9876543216#000
a. Two confirmation beeps = change accepted
b. One confirmation beep = change not accepted
Normally Open fire alarm contact active (looking for an open from the Fire Alarm relay to unlock the
doors)
1. Enter *567 or currently programmed secondary code
2. Enter *9876543216#001
a. Three confirmation beeps = change accepted
b. One confirmation beep = change not accepted
Latching Fire Alarm
Fire Alarm
Factory Default Disabled
To enable the Latching Fire Alarm
1. Enter *567*9876543216 #999
• Four confirmation beeps = change accepted
• One confirmation beep = change not accepted
To disable the Latching Fire Alarm
1. Enter *567*9876543216 #909
• Five confirmation beeps = change accepted
• One confirmation beep = change not accepted
Locking of Life Safety 101 Features
This feature will lock the delayed egress and fire alarm settings. This feature is NON REVERSIBLE
and cannot be undone by initializing the panel. Make sure the Life Safety 101 features are correct and
meet your local authorities’ requirements before locking the feature. To undo this feature the panel
will have to be sent back to Secure Care Products, Inc. to be reprogrammed at the standard repair
fee.
1.
Enter *309*9876543219
Software Version
To verify the software version:
1. Enter *567*2 and hold
2.
Count each series of beeps. The 4 series of beeps will represent the 4 digit software version
number.
Example: 2 beeps pause, 5 beeps pause, 10 beeps pause, 10 beeps indicates version 2.500.
Elevator Mode
In default operation, the AUX relay will operate normally, the NO relay will CLOSE and the NC
relay will OPEN during alarms. The relays will also remain in there defaults states if the ID Exit Panel
loses all power. When the Elevator Mode feature is enabled, the AUX relays will operate normally
but if the ID Exit Panel loses power, the AUX relays will change state. This feature only affects the
AUX relays when the power is powered down.
Elevator Mode
Factory Default Disabled
To enable the elevator mode
1. Enter *567 *0 hold the 0 until 1 beep is heard
To disable the elevator mode
1. Enter *567 *0 hold the zero until 2 beeps are heard
When the elevator mode feature is enabled the AUX relays will change to the alarm state when the
panel loses power. (relays will change state).
Loiter Alarm
This feature, when programmed and enabled, allows the ID Exit Panel to create a unique audible
alarm indicating a transmitter is in proximity of a monitored door for too long. If the transmitter were
to leave the monitored area after the alarm sounds, the alarm would reset automatically without staff
intervention.
Loiter Alarm
Factory Default
Disabled
Enable Factory Default 60 sec.
To enable loiter alarm feature follow the three listed steps without pausing for greater than one
second between keystrokes.
1. Enter *567 or currently programmed secondary code
2. Enter *9876543218#999
a. Four confirmation beeps = change accepted
To disable loiter alarm feature follow the three listed steps without pausing for greater than one
second between keystrokes.
1. Enter *567 currently programmed secondary code
2. Enter *9876543218#909
a. Three confirmation beeps = change accepted
To change the time of loiter alarm feature in seconds, follow the three listed steps without pausing
for greater than one second between keystrokes. Acceptable range of values: 15 seconds “015”
15
minutes “900”
1. Enter *567 or currently programmed secondary code
SECTION 9 PROGRAMMING
2. Enter *9876543218#XXX (where “XXX” = time in seconds; example -30 sec. = “030”,
3 min. = “180”)
a. Two confirmation beeps = change accepted
b. One confirmation beep = change not accepted
Advanced Security Mode
In Advanced Security Mode the Primary Reset Code (*234 or equivalent) and Tertiary Reset Code (*751 or
equivalent) will not allow the escort of a monitored resident. The Primary Reset Code may still be used to reset
an alarm condition. If a Push Button is used in Advanced Security Mode, it will not allow access while a
monitored resident is within the detection range. An audible alarm will sound while the Push Button is pressed
and a monitored resident is nearby. In the absence of a monitored resident the Push Button and Primary Reset
Code will work as usual. Enabling the Advanced Security Mode feature has no affect on the Secondary Reset
Codes (*567 or equivalent) operation.
Advanced Security Mode
Factory Default
Enabled
To enable the advanced security mode, follow the three listed steps without pausing for greater than
one second between keystrokes.
1. Enter *567 or currently programmed Secondary code
2. Enter *9876543215#999
• Four confirmation beeps = change accepted
To disable the advanced security mode, follow the three listed steps without pausing for greater than
one second between keystrokes.
1. Enter *567 or currently programmed Secondary code
2. Enter *9876543215#909
• Three confirmation beeps = change accepted
Antenna Selection
Each ID Exit Panel has an integrated antenna system in the unit. However, due to special requirements of
certain installations, you may be inclined to add an external antenna to the ID Exit Panel. The following steps
will allow you to choose the proper setup for your installation needs.
To change the selection of antennas
1. Enter *567 (or currently programmed Secondary Code) followed by *5, holding the 5
until the panel beeps..
• One beep = board antenna is active
• Two beeps = remote antenna(s) is active
• Three beeps = both the on board antenna and remote antenna(s) are active
• Four beeps = neither antennas are active
To Enable or Disable the Signal LED on the ID Exit Panel
•
Enter *567*6 and hold until beep is heard
Factory Default LED Enable
SECTION 9 PROGRAMMING
•
•
Two Beeps = Signal LED Disabled
One Beeps = Signal LED Enabled
Antenna Range Adjustment
Each door system installation will be unique in many ways. Consider all of the local environmental
factors of construction around the system location; the types of materials used, the construction
methods used, and amount of foot traffic around and through the door area. Each system will require
tuning for the required coverage at each location independently. Every panel ships from Secure Care
Products Inc. with a threshold value of 200. The following steps will guide you during the
adjustment.
1. Enter *567 (or currently programmed secondary code) *9876543219
• Five beeps indicate that you are in range adjustment mode
2. Enter “1” and the current threshold will be given in a series of beeps.
• 1-9 beeps indicate its numeric value.
• Ten beeps indicate a value of zero.
3. Enter “*” followed by three digits of desired threshold value
• Higher the value = shorter range
• Lower the value = longer range
4. Enter “0” to select the on board antenna or remote antenna
• Four beeps = adjust the remote antenna
• Two beeps = adjust the onboard antenna
5. Enter “#” to get out of the range change mode or wait one minute.
• Three beeps = end of range adjustment mode.
Testing the CAN Bus
To test the CAN bus connection:
1. Enter *567 *1 and hold the one
• One beep = the bus is not connected
• Four beeps = communicating to at least one other device.
PM Mode Feature
The PM Mode feature allows the user to select a single event, (one lock time and one unlock time) to
automatically lock and unlock the door system for everyday of the week. This will allow more control of
unauthorized traffic through the protected door during those times.
PM Mode
Factory Default
Disabled
SECTION 9 PROGRAMMING
To program the panel to arm and disarm at a selected time:
1. Enter *567 *987654321 and hold the one until one beep is heard
2. Enter current time of the day in military time
• Two beeps=accepted
3. Enter unlock time in military time
• Three beeps=accepted
4. Enter lock time in military time
• Four beeps=accepted
To enable the PM mode feature
1. Enter *567 *987654321 and hold the one until one beep is heard
2. Enter 9999
• Four beeps=accepted
To disable the PM mode
1. Enter *567 *987654321 and hold the one until one beep is heard
2. Enter 9009
• One beep=accepted
The ID Exit Panel can be programmed to be armed 24 hours a day. Following the programming
steps above, set Current Time, PM Off Time, and PM On Time with the same time.
Example: Enter *567*987654321 and hold the one until one beep is heard
Current time = 0000
PM off time = 0000
PM on time = 0000
Then enter *567*987654321 hold the one until one beep is heard
Enter 9999 ( One beep=accepted )
Display PM Times
1.
2.
3.
4.
5.
6.
Enter *567 *987654321 hold the one until one beep is heard
Enter 8888 Current time of the day while in PM will blink
Enter *567 *987654321 hold the one until one beep is heard
Enter 7777 PM off time will blink
Enter *567 *987654321 hold the one until one beep is heard
Enter 6666 PM on time will blink
Setting Exit Panel ID Code
Each ID Exit Panel requires its own unique ID code for reporting purposes on the CAN bus (if used). An event
message will then be transmitted on the CAN bus beginning with the Exit Panel ID code followed by the
message string. The Exit Panel ID is also supervised by the XIU for power. Only ID 001-095 are valid ID
codes.
Panel ID Code
Factory Default
255
To change the panel ID code, follow the three listed steps without pausing for greater than one
second between keystrokes.
1. Enter *567 or currently programmed secondary code
2. Enter *9876543213#XXX (XXX = three digit number)
1) Two confirmation beeps = change accepted
2) Single confirmation beep = change declined
To view the panel ID code, follow the three listed steps without pausing for greater than one second
between keystrokes.
1. Enter *567 or currently programmed secondary code
Enter *9876543213#999. The ID Code will be given in three series of blinks (# of blinks for
number in the code, i.e. one blink = 1, etc… ten blinks = 0) separated by pauses