council chambers - City of New Westminster

council chambers - City of New Westminster
NEW WESTMINSTER CITY HALL
AV SYSTEMS
COUNCIL CHAMBERS
TECHNOLOGY
DRAWING LIST
TITLE
DWG#
1.
T100
COVER PAGE
2.
T101
EXISTING DEVICES
3.
T102
NEW COUNCIL CHAMBER LAYOUT
T103
SECTIONS
ELECTRICAL NON-METALLIC TUBING (ENT, COMMONLY REFERRED TO AS "CORELINE") IS
NOT ACCEPTABLE.
CONTRACTOR TO PROVIDE COVERS ON ALL JUNCTION BOXES, A PULL STRING IN ALL
INSTALLED CONDUITS, AND NYLON GROMMETS ON ALL CONDUIT STUBS.
PROVIDE NYLON BUSHINGS FOR CONDUITS, COVERS FOR ALL JUNCTION BOXES AND
PULLSTRINGS IN ALL EMPTY CONDUITS.
TO TIA STANDARDS FOR MINIMUM BEND RADIUS ON ALL CONDUITS.
PROVIDE SEISMIC RESTRAINT AS REQUIRED BY LOCAL BUILDING CODE. PROVIDE SEISMIC
REVIEW BY SEISMIC PROFESSIONAL ENGINEER. SUBMIT SIGNED AND SEALED REVIEW
REPORT WITH OPERATIONS AND MAINTENANCE MANUALS.
PROVIDE FIRE STOPPING AS REQUIRED BY LOCAL BUILDING CODE. FIRE STOPPING
ASSEMBLY MUST BE RATED AS SUCH TO MAINTAIN THE FIRE RATING WHERE THE
PENETRATION OCCURS. CONSULT WITH FIRE STOPPING EXPERT TO REVIEW FIRESTOPPING
INSTALLATION. SUBMIT REVIEW REPORT WITH THE OPERATIONS AND MAINTENANCE
MANUAL.
ALL SURFACE MOUNT AV EQUIPMENT REQUIRES SUFFICIENT BACKING.
INSTALLATION MUST CONFORM TO BC BUILDING CODE.
5.
T104
WORKSPACE DETAILS
T105
EQUIPMENT DETAILS
T200
AV SYSTEMS SCHEMATIC
T201
AV CONTROL SYSTEMS
TECHNOLOGY
SYMBOL SCHEDULE
GENERAL NOTES
6.
7.
AV WIRING NOTES
1.
2.
TYPICAL VOICE/DATA WALL OUTLET.
CAM
FB
EXISTING PTZ CAMERA
EXISTING FLOORBOX
EXISTING CEILING MOUNT PROJECTOR
EXISTING CEILING MOUNT PROJECTOR
SCREEN
IP
CAM
EXISTING IP CAMERA
1
WIDE ANGLE PTZ CAMERA
3
LONG THROW PTZ CAMERA
CEILING MOUNT PROJECTOR
FREE AIR RUNNING OF CABLES WITHIN ACCESSIBLE DROP CEILING SPACES IS
ACCEPTABLE. PROVIDE J-HOOKS TO SUPPORT THE CABLES. ALL CABLES MUST BE
FT6 RATED.
ALL CABLING FOR AV AND AV CONTROL SYSTEM DEVICES TO BE SUPPLIED AND
INSTALLED BY AV CONTRACTOR.
CEILING MOUNT PROJECTOR SCREEN
IP
EXISTING IP CAMERA TO REMAIN
MICROPHONE STATION
AV MOUNTING NOTES
1.
2.
3.
ALL FASTENING LOCATIONS MUST HAVE SCANS TO LOCATE. RE-BAR PRIOR TO
INSTALL.
FOR SCANNING OF ALL FASTENING BOLT LOCATIONS, CUTTING AND CORING, AV
CONTRACTOR MUST BE CO-ORDINATE WITH SCANNING CONTRACTOR.
ALL MOUNTING LOCATIONS MUST BE APPROVED BY STRUCTURAL ENGINEER.
BACKUP MICROPHONE
T
TOUCH PANEL
AV INPUT PLATE
FLOORBOX
MILLWORK NOTES
1.
2.
LOCATIONS OF AV DEVICES IN MILLWORK MUST BE CONFIRMED ON SITE WITH
OWNER'S REPRESENTATIVE.
MILLWORK CUTOUTS ARE TO BE COMPLETED BY MILLWORK CONTRACTOR.
80" LCD MONITOR
CEILING SPEAKER
PROJECT INFORMATION
NAME OF PROJECT:
NEW WESTMINSTER CITY HALL COUNCIL CHAMBER
CIVIC ADDRESS:
511 ROYAL AVENUE NEW WESTMINSTER, BC V3L 1H9.
Drawing scale may be affected by printing, scanning or copying.
650-2700 PRODUCTION WAY
BURNABY, BC V5A 4X1
PH.604.676.9545
ACUMENENGINEERING.CA
THIS DRAWING AND ALL ASSOCIATED DOCUMENTS ARE AN INSTRUMENT OF SERVICE AND ARE, AND WILL, AT ALL TIMES REMAIN EXCLUSIVE PROPERTY
OF ACUMEN ENGINEERING LTD. ALL DESIGNS AND OTHER INFORMATION SHOWN ON THIS DRAWING ARE FOR USE ONLY ON THE SPECIFIED PROJECT;
AND MAY BE USED ONLY FOR THE ISSUED PURPOSE AS STATED HEREIN. PAYMENT OF ALL SUMS DUE TO ACUMEN ENGINEERING LTD. UP TO THE DATE
OF THE INTENDED USE OF THIS DRAWING IS A CONDITION PRECEDENT TO THE USE THEREOF. COPYRIGHT OF THIS DRAWING, ITS CONTENT AND
DESIGN ARE RESERVED BY ACUMEN ENGINEERING LTD. THE DRAWING AND THE INFORMATION CONTAINED HEREIN SHALL NOT BE REPRODUCED IN
WHOLE, OR IN PART, WITHOUT PRIOR WRITTEN PERMISSION FROM ACUMEN ENGINEERING LTD.
BY
DATE
REV
DESCRIPTION
-
ISSUED FOR 75% REVIEW
ACUMEN
2015-06-09
-
ISSUED FOR 95% REVIEW
ACUMEN
2015-06-17
-
ISSUED FOR TENDER ONLY
ACUMEN
2015-06-19
CITY OF NEW WESTMINSTER
Council Chambers
COVER
COUNCIL CHAMBERS
T100
NOTE:
SYMBOL SCHEDULE
EXISTING DEVICES SHOWN ON THE DRAWING IS FOR
INFORMATION ONLY. EXACT LOCATION TO BE CONFIRMED BY
CONTRACTOR ON SITE.
CAM
FB
IP
CAM
CAM
EXISTING PTZ CAMERA
EXISTING FLOORBOX
9'-6 1/4"
EXISTING CEILING MOUNT
PROJECTOR
EXISTING CEILING MOUNT
PROJECTOR SCREEN
IP
CAM
EXISTING IP CAMERA
COUNCIL EAST WALL SECTION
1
1/4" = 1'
+95" AFF
+84" AFF
CAM
CAM
CAM
7'-0"
7'-11"
CAM
FB
2
COUNCIL NORTH WALL SECTION
1/4" = 1'
FOR REFERENCE ONLY
FB
FB
CAM
FB
IP
CAM
FB
EXISTING LIGHTING
CONTROL INTERFACE
EXISTING MOVABLE
PRODUCTION RACK
EXISTING CORING
EXISTING WALL
MOUNT AV RACK
6'-4"
CAM
CAM
+76" AFF
3
COUNCIL SOUTH WALL SECTION
1/4" = 1'
4
COUNCIL EXISTING DEVICES PLAN
1/4" = 1'
Drawing scale may be affected by printing, scanning or copying.
650-2700 PRODUCTION WAY
BURNABY, BC V5A 4X1
PH.604.676.9545
ACUMENENGINEERING.CA
THIS DRAWING AND ALL ASSOCIATED DOCUMENTS ARE AN INSTRUMENT OF SERVICE AND ARE, AND WILL, AT ALL TIMES REMAIN EXCLUSIVE PROPERTY
OF ACUMEN ENGINEERING LTD. ALL DESIGNS AND OTHER INFORMATION SHOWN ON THIS DRAWING ARE FOR USE ONLY ON THE SPECIFIED PROJECT;
AND MAY BE USED ONLY FOR THE ISSUED PURPOSE AS STATED HEREIN. PAYMENT OF ALL SUMS DUE TO ACUMEN ENGINEERING LTD. UP TO THE DATE
OF THE INTENDED USE OF THIS DRAWING IS A CONDITION PRECEDENT TO THE USE THEREOF. COPYRIGHT OF THIS DRAWING, ITS CONTENT AND
DESIGN ARE RESERVED BY ACUMEN ENGINEERING LTD. THE DRAWING AND THE INFORMATION CONTAINED HEREIN SHALL NOT BE REPRODUCED IN
WHOLE, OR IN PART, WITHOUT PRIOR WRITTEN PERMISSION FROM ACUMEN ENGINEERING LTD.
BY
DATE
REV
DESCRIPTION
-
ISSUED FOR 75% REVIEW
ACUMEN
2015-06-09
-
ISSUED FOR 95% REVIEW
ACUMEN
2015-06-17
-
ISSUED FOR TENDER ONLY
ACUMEN
2015-06-19
CITY OF NEW WESTMINSTER
Council Chambers
EXISTING DEVICES
COUNCIL CHAMBERS
T101
NEW PTZ CAMERA AT
EXISTING CAMERA LOCATION
NEW PTZ CAMERA AT
EXISTING CAMERA LOCATION
1
1
NEW CORING LOCATION.
LOCATION TO BE CONFIRMED
ON SITE.
NEW CORING LOCATION.
LOCATION TO BE CONFIRMED
ON SITE.
AV
AV
NEW CORING LOCATION.
LOCATION TO BE CONFIRMED
ON SITE.
3
3
NEW CORING LOCATION.
LOCATION TO BE CONFIRMED
ON SITE.
AV
AV
AV
8'-6"
8'-6"
AV
T
NEW PTZ CAMERA AT
EXISTING CAMERA LOCATION
NEW PTZ CAMERA AT
EXISTING CAMERA LOCATION
3
T
3
T
NEW CORING LOCATION.
LOCATION TO BE CONFIRMED
ON SITE.
AV
AV
NEW CORING LOCATION.
LOCATION TO BE CONFIRMED
ON SITE.
AV
AV
AV
NEW PRODUCTION RACK
EXISTING CRESTRON LIGHTING
CONTROL INTERFACE
T
AV
WALL MOUNT TOUCH PANEL
+ 60" AFF . CONFIRM EXACT
LOCATION ON SITE.
AV
6
T103
NEW PRODUCTION RACK
5
NEW CORING LOCATION.
LOCATION TO BE
CONFIRMED ON SITE.
EXISTING IP CAMERA TO
REMAIN
T103
NEW WALL MOUNT RACK
NEW PTZ CAMERA AT
EXISTING CAMERA LOCATION
NEW PTZ CAMERA AT
EXISTING CAMERA LOCATION
80" LCD MONITOR
80" LCD MONITOR
1
AV
1
COUNCIL CHAMBER PLAN - COMMITTEE OF WHOLE
T102
6
5
NEW CORING LOCATION.
LOCATION TO BE
CONFIRMED ON SITE.
NEW WALL MOUNT RACK
1
IP
WALL MOUNT TOUCH PANEL
+ 60" AFF . CONFIRM EXACT
LOCATION ON SITE.
AV
AV
IP
EXISTING CRESTRON LIGHTING
CONTROL INTERFACE
AV
NEW CORING LOCATION.
LOCATION TO BE CONFIRMED
ON SITE.
AV
AV
EXISTING IP CAMERA TO
REMAIN
T
AV
NEW CORING LOCATION.
LOCATION TO BE CONFIRMED
ON SITE.
AV
T
2
1/4" = 1'-0"
T102
AV
COUNCIL CHAMBER PLAN - COUNCIL MEETING
1/4" = 1'-0"
SYMBOL SCHEDULE
TEL.
1
WIDE ANGLE PTZ CAMERA
3
LONG THROW PTZ CAMERA
CEILING MOUNT PROJECTOR
CEILING MOUNT
PROJECTION SCREEN
LEGISLATIVESTORAGE
IP
EXISTING IP CAMERA TO
REMAIN
MICROPHONE STATION
19'-8"
1
REFER TO ELECTRICAL DRAWING
FOR ROUTING OF CONDUIT
BACKUP MICROPHONE
NEW AV RACK
LOCATION TO BE
CO-ORDINATED ON SITE
SERVER ROOM
T
AV
TOUCH PANEL
AV INPUT PLATE
FLOORBOX
80" LCD MONITOR
CEILING SPEAKER
3
T102
COUNCIL CHAMBER REFLECTED CEILING PLAN
4
1/4" = 1'-0"
T102
SERVER ROOM PLAN
1/4" = 1'-0"
Drawing scale may be affected by printing, scanning or copying.
650-2700 PRODUCTION WAY
BURNABY, BC V5A 4X1
PH.604.676.9545
ACUMENENGINEERING.CA
THIS DRAWING AND ALL ASSOCIATED DOCUMENTS ARE AN INSTRUMENT OF SERVICE AND ARE, AND WILL, AT ALL TIMES REMAIN EXCLUSIVE PROPERTY
OF ACUMEN ENGINEERING LTD. ALL DESIGNS AND OTHER INFORMATION SHOWN ON THIS DRAWING ARE FOR USE ONLY ON THE SPECIFIED PROJECT;
AND MAY BE USED ONLY FOR THE ISSUED PURPOSE AS STATED HEREIN. PAYMENT OF ALL SUMS DUE TO ACUMEN ENGINEERING LTD. UP TO THE DATE
OF THE INTENDED USE OF THIS DRAWING IS A CONDITION PRECEDENT TO THE USE THEREOF. COPYRIGHT OF THIS DRAWING, ITS CONTENT AND
DESIGN ARE RESERVED BY ACUMEN ENGINEERING LTD. THE DRAWING AND THE INFORMATION CONTAINED HEREIN SHALL NOT BE REPRODUCED IN
WHOLE, OR IN PART, WITHOUT PRIOR WRITTEN PERMISSION FROM ACUMEN ENGINEERING LTD.
BY
DATE
REV
DESCRIPTION
-
ISSUED FOR 75% REVIEW
ACUMEN
2015-06-09
-
ISSUED FOR 95% REVIEW
ACUMEN
2015-06-17
-
ISSUED FOR TENDER ONLY
ACUMEN
2015-06-19
CITY OF NEW WESTMINSTER
Council Chambers
NEW COUNCIL CHAMBER LAYOUT
T102
NEW DIGITAL CLOCK
1'-0"
1'-0"
19'-8"
NEW PTZ CAMERA AT EXISTING
CAMERA LOCATION
IP
7'-5 1/2"
3
EXISTING IP CAMERA TO REMAIN
8'-6"
3'-0"
3'-0"
1
3
9'-0"
10'-11 3/16"
7'-0"
7'-0"
7'-0"
6'-6 9/16"
NEW DIGITAL CLOCK
NEW PTZ CAMERA AT
EXISTING CAMERA LOCATION
1
T103
NORTH WALL SECTION
2
1/4" = 1'-0"
T103
WEST WALL SECTION
3
1/4" = 1'-0"
T103
EAST WALL SECTION
1/4" = 1'-0"
1'-0"
1'-0"
19'-8"
WALL MOUNT
RACK
FRONT VIEW
WALL MOUNT RACK
SIDE VIEW
5'-0"
22" MONITOR
MONITOR MOUNT
ATTACHED TO
PLATE
1
PRODUCTION RACK
CONSOLE
6
5'-0"
5'-0"
6'-8"
6'-4"
PRODUCTION RACK
CONSOLE
WITH 22" MONITOR
AV
2
T103
5
ROLLING
PRODUCTION RACK
SIDE VIEW
NEW PTZ CAMERA AT
EXISTING CAMERA LOCATION
4
T103
SOUTH WALL SECTION
5
1/4" = 1'-0"
T103
ROLLING
PRODUCTION RACK
FRONT VIEW
AV CLOSET SOUTH ELEVATION
AV CLOSET WEST ELEVATION
6
1/2" = 1'-0"
T103
1/2" = 1'-0"
7
T103
AV CLOSET WEST ELEVATION
1/2" = 1'-0"
Drawing scale may be affected by printing, scanning or copying.
650-2700 PRODUCTION WAY
BURNABY, BC V5A 4X1
PH.604.676.9545
ACUMENENGINEERING.CA
THIS DRAWING AND ALL ASSOCIATED DOCUMENTS ARE AN INSTRUMENT OF SERVICE AND ARE, AND WILL, AT ALL TIMES REMAIN EXCLUSIVE PROPERTY
OF ACUMEN ENGINEERING LTD. ALL DESIGNS AND OTHER INFORMATION SHOWN ON THIS DRAWING ARE FOR USE ONLY ON THE SPECIFIED PROJECT;
AND MAY BE USED ONLY FOR THE ISSUED PURPOSE AS STATED HEREIN. PAYMENT OF ALL SUMS DUE TO ACUMEN ENGINEERING LTD. UP TO THE DATE
OF THE INTENDED USE OF THIS DRAWING IS A CONDITION PRECEDENT TO THE USE THEREOF. COPYRIGHT OF THIS DRAWING, ITS CONTENT AND
DESIGN ARE RESERVED BY ACUMEN ENGINEERING LTD. THE DRAWING AND THE INFORMATION CONTAINED HEREIN SHALL NOT BE REPRODUCED IN
WHOLE, OR IN PART, WITHOUT PRIOR WRITTEN PERMISSION FROM ACUMEN ENGINEERING LTD.
BY
DATE
REV
DESCRIPTION
-
ISSUED FOR 75% REVIEW
ACUMEN
2015-06-09
-
ISSUED FOR 95% REVIEW
ACUMEN
2015-06-17
-
ISSUED FOR TENDER ONLY
ACUMEN
2015-06-19
CITY OF NEW WESTMINSTER
Council Chambers
SECTIONS
COUNCIL CHAMBERS
T103
TABLE TOP
TOUCHSCREEN
FOR CITY CLERK
CONF.STATION
AV INPUT
TABLE TOP
TOUCHSCREEN
FOR MAYOR
BACKUP MIC
TOGGLE SWITCH
CHAMBER CLERK
CITY CLERK
SERVER ROOM EQUIPMENT RACK BTU CALC
44U
AV INPUT
CRESTRON CP 3
SWITCH
OWNER SUPPLIED
POWER/DATA/USB
CHARGING
MAYOR
DESCRIPTION
CONTROL PROCESSOR
OWNER SUPPLIED SWITCH
AV MATRIX
WIRELESS PRESENTATION
DISCUSSION CENTRAL UNIT
OWNER SUPPLIED DSP
DSP
POWER AMPLIFIER
40U
CABLING FOR
TOUCHSCREEN
CABLE TRAY
(TYPICAL OF 2)
CABLE TRAY
CRESTRON
AV MATRIX
35U
HATCH
MANUFACTURER
CRESTRON
N/A
CRESTRON
WEPRESENT
SENNHEISER
BIAMP
BIAMP
TOA
MODEL
CP3
N/A
DM-MD32X32
WIPG1000
ADN CU1
AUDIA
TESIRA FORTE
DA 250
T104
2
3/4" = 1'-0"
T104
24
100
1100
50
245
100
100
1200
1
1
1
1
2
1
1
1
25
BTU/Hr
EFFICIENCY
24
100
1100
50
490
100
100
1200
5.00%
5.00%
6.00%
0.00%
0.00%
0.00%
0.00%
0.00%
50
325
3000
171
1673
342
342
4096
3164W
0W
9,999BTU/Hr
WEPRESENT
SENNHEISER
ADN CU 1
SENNHEISER
ADN CU 1
BIAMP AUDIA
OWNER SUPPLIED
BIAMP TESIRA
FORTE
TOA DA 250
25U
CHAMBER CLERK / CITY CLERK / MAYOR ELEVATION
1
2
14
1
2
2
2
1
TOTAL
POWER
30U
(2) 1.5" CONDUITS
TO AV CABLING SPACE
1
RACK
POWER
QTY
UNITS CONSUMPTION
TYPICAL WORKSPACE SECTION
20U
3/4" = 1'-0"
15U
DISPLAY MONITOR
CONF. STATION
TOGGLE SWITCH
AV INPUT PLATE
POWER/DATA/USB
CHARGING
10U
5U
CONNECT TO
PRESENTATION
TABLE
CABLE TRAY
6
MOVABLE TABLE PLAN
TYPICAL COUNCILOR WORKSPACE ELEVATION
3
T104
4
3/4" = 1'-0"
T104
T104
SERVER ROOM RACK LAYOUT
NTS
COMMITTEE OF WHOLE MOVABLE TABLES
AV CLOSET WALL MOUNT RACK BTU CALC
3/4" = 1'-0"
12U
NETWORK SWITCH
O/S POWER BAR
O/S SHURE UA844
O/S (2) SHURE SLX4
LISTEN LT-800
EXTRON SMP351
2 RU
RACKMOUNT DRAWER
RDL RU-MX4
AV PANEL
10U
5U
AUDIO INPUT
FOR CONNECTION OF PTT
MICROPHONE SYSTEM. PLATE &
CONNECTOR ON BOTH SIDE OF
TABLE
AV INPUT PLATE
DESCRIPTION
ANTENNA DISTRIBUTION
DIVERSITY RECEIVER
STREAMING MEDIA PROCESSOR
AUDIO MIXER
MANUFACTURER
MODEL
UA844
SLX44
SMP351
RU-MX4
SHURE
SHURE
EXTRON
RDL
RACK
POWER
QTY
UNITS CONSUMPTION
1
1
1
2
25
10
30
10
TOTAL
POWER
1
1
1
1
5
EFFICIENCY
BTU/Hr
25
10
30
10
50.00%
50.00%
0.00%
43
18
96
35
75W
0W
192BTU/Hr
TOTAL
POWER
EFFICIENCY
"O/S" DENOTED "OWNER SUPPLIED"
7
T104
AV CLOSET WALL MOUNT RACK LAYOUT
NTS
PRESENTATION DESK SIDE ELEVATION
PRESENTATION DESK PLAN
AV CLOSET PRODUCTION RACK BTU CALC
14U
POWER BAR
UPS
QCCU
QCCU
QCCU
QCCU
2 RU
RACKMOUNT DRAWER
10U
DESCRIPTION
UPS
CAMERA CONTROL UNIT
MANUFACTURER
N/A
VADDIO
MODEL
N/A
ROBOSHOT
RACK
POWER
QTY
UNITS CONSUMPTION
1
4
15
100
1
4
BTU/Hr
15
400
5.00%
5.00%
49
1297
415W
0W
1,346BTU/Hr
5U
HATCH
CABLE TRAY
(TYPICAL OF 2)
CABLE TRAY
5
(2) 1.5" CONDUITS
TO AV CABLING SPACE
8
T104
PRESENTATION DESK ELEVATION
5
T104
AV CLOSET PRODUCTION RACK LAYOUT
NTS
PRESENTATION DESK SECTION
PRESENTATION PODIUM DETAILS
3/4" - 1'-0"
Drawing scale may be affected by printing, scanning or copying.
650-2700 PRODUCTION WAY
BURNABY, BC V5A 4X1
PH.604.676.9545
ACUMENENGINEERING.CA
THIS DRAWING AND ALL ASSOCIATED DOCUMENTS ARE AN INSTRUMENT OF SERVICE AND ARE, AND WILL, AT ALL TIMES REMAIN EXCLUSIVE PROPERTY
OF ACUMEN ENGINEERING LTD. ALL DESIGNS AND OTHER INFORMATION SHOWN ON THIS DRAWING ARE FOR USE ONLY ON THE SPECIFIED PROJECT;
AND MAY BE USED ONLY FOR THE ISSUED PURPOSE AS STATED HEREIN. PAYMENT OF ALL SUMS DUE TO ACUMEN ENGINEERING LTD. UP TO THE DATE
OF THE INTENDED USE OF THIS DRAWING IS A CONDITION PRECEDENT TO THE USE THEREOF. COPYRIGHT OF THIS DRAWING, ITS CONTENT AND
DESIGN ARE RESERVED BY ACUMEN ENGINEERING LTD. THE DRAWING AND THE INFORMATION CONTAINED HEREIN SHALL NOT BE REPRODUCED IN
WHOLE, OR IN PART, WITHOUT PRIOR WRITTEN PERMISSION FROM ACUMEN ENGINEERING LTD.
BY
DATE
REV
DESCRIPTION
-
ISSUED FOR 75% REVIEW
ACUMEN
2015-06-09
-
ISSUED FOR 95% REVIEW
ACUMEN
2015-06-17
-
ISSUED FOR TENDER ONLY
ACUMEN
2015-06-19
CITY OF NEW WESTMINSTER
Council Chambers
WORKSPACE DETAILS
COUNCIL CHAMBERS
T104
6'-1 9/16"
3 3/8"
TOP VIEW
3 3/8"
FINISHED WALL
ALL CABLING TO BE SECURED/
CONCEALED TO PROVIDE
A CLEAN INSTALL.
5'-10"
WALL MOUNT TOP VIEW
7.0" [178.76]
1/2"
10 1/8"
SIDE VIEW 1
2"
8 9/16"
4.8" [121.92]
FRONT VIEW
9 1/2"
2 3/8"
2.2" [56.45]
WALL MOUNT FRONT VIEW
7.0" [178.76]
2
SIDE VIEW 2
1'-8 7/8"
5.5" [139.89]
3'-7 1/16"
7.0" [178.21]
2 1/4"
4 5/8"
3.459 [87.87]
3'-3 1/2"
6 7/16"
5 3/8"
3.5" [87.87]
10 9/16"
REAR VIEW
60"
WALL MOUNT BACK VIEW
7 7/8"
5'
5.4" [137.01]
6.7" [170.75]
1/4" x 20
INSERT
BOTTOM VIEW
WALL MOUNT BOTTOM VIEW
GROUND
WALL MOUNT SIDE VIEW
3"
4 13/16"
T105
PROJECTOR MOUNTING DETAILS
1" = 1'-0"
TABLE TOP FRONT VIEW
PROJECTOR SCREEN DETAILS
1
T105
4
4"
5 5/16"
10 1/8"
T105
PTZ CAMERA DETAILS
3" = 1'-0"
6'-8"
4 13/16"
2
2'-3"
TABLE TOP SIDE VIEW
1/2" = 1'-0"
3
T105
TOUCHSCREEN CONTROL PANEL
NTS
4-CONDUCTOR
CABLING
WHITE (COMMON)
120VAC 60Hz BLACK (HOT)
GREEN
MOTOR
1 5/16"
GREEN
4 1/2"
4 1/2"
4 1/8"
SUPPLIED AND
SPLITTER
INSTALLED BY DRY CONTACTS
AV
CONTRACTOR
1 7/16"
2 5/8"
4 1/8"
SUPPLIED AND
INSTALLED BY
ELECTRICAL
CONTRACTOR
3 1/2"
1 3/4"
GROUND
TO CASE
UP
+5V
COM
DN
GROUND MUST BE
CONNECTED TO
BUILDING GROUND
TO 3-POSITION
LOW-VOLTAGE
WALL SWITCH
COUNCIL CHAMBER FINISHED FLOOR
ELECTRIC PROJECTION SCREEN WIRING DETAIL
6
ELECTRICAL PROJECTION SCREEN WIRING DETAIL
T105
5
NTS
DIV.26 TO PROVIDE J-HOOKS
AND/OR CONDUIT(S).
7
T105
T105
5 1/4"
3 1/2"
TYPICAL AV TRANSMITTER DETAILS
6" = 1'-0"
8
T105
TOGGLE SWITCH DETAILS
9
3" = 1'-0"
T105
80" LCD TV ELEVATION
1/2" = 1'-0"
COUNCILLOR STATION AV INPUT DETAIL
6" = 1'-0"
35mm CONDUIT STUBBED-OUT
TO ACCESSIBLE CEILING SPACE.
PROVIDE NYLON BUSHING
AND PULL STRING.
(BY DIV.26)
4"[103mm] SQUARE DEEP BOX
3-1
/
ARCHIVE
RECORD
2"
COMPOSITE
COMPOSITE
COMPOSITE
HD/SDI
VARIABLE AUDIO OUTPUT
USE FLAT RECTANGULAR
OPENING (TILE) MUDRINGS
NOTE:
ROUGH-INS BY DIV. 26
CABLING AND TERMINATIONS BY DIV. 27
11
T105
10
T105
SDI
FIXED AUDIO OUTPUT
AV PRODUCTION AUDIO / VIDEO OUTPUT PLATE
6" = 1'-0"
TYPICAL WALLMOUNTED AV BOX
1-1/2" = 1'-0"
NOTES:
1. PATHWAYS FOR TECHNOLOGY CABLES SHALL BE PARALLEL TO
BUILDING LINES. HORIZONTAL CABLING SHALL BE SUPPORTED
BY J-HOOKS(BY DIV.27), CABLE TRAYS AND/OR PLACED IN CONDUIT.
MA
XI
M
MU
FASTENER
EE
3F
1'-5 5/16"
3. CABLES OF DIFFERENT SYSTEMS
SHALL BE BUNDLED SEPARATELY.
T
1'-3 5/16"
2. THE NUMBER OF CABLES SUPPORTED BY J-HOOKS AND THE
SPACING BETWEEN THE J-HOOKS SHALL FOLLOW
MANUFACTURERS RECOMMENDATIONS.
A/V
CABLE
VELCRO WRAPS FOR
EVERY 2 METER
J-HOOK
12
T105
1'-1 13/16"
TYPICAL WALLMOUNTED AV DEVICE
1-1/2" = 1'-0"
13
T105
PRESS FEED FLOOR BOX DETAILS
3" = 1'-0"
14
T105
PRESENTATION TABLE AUDIO INPUT DETAIL
PTT CONNECTION PLATE DETAIL
15
6" = 1'-0"
T105
6" = 1'-0"
Drawing scale may be affected by printing, scanning or copying.
650-2700 PRODUCTION WAY
BURNABY, BC V5A 4X1
PH.604.676.9545
ACUMENENGINEERING.CA
THIS DRAWING AND ALL ASSOCIATED DOCUMENTS ARE AN INSTRUMENT OF SERVICE AND ARE, AND WILL, AT ALL TIMES REMAIN EXCLUSIVE PROPERTY
OF ACUMEN ENGINEERING LTD. ALL DESIGNS AND OTHER INFORMATION SHOWN ON THIS DRAWING ARE FOR USE ONLY ON THE SPECIFIED PROJECT;
AND MAY BE USED ONLY FOR THE ISSUED PURPOSE AS STATED HEREIN. PAYMENT OF ALL SUMS DUE TO ACUMEN ENGINEERING LTD. UP TO THE DATE
OF THE INTENDED USE OF THIS DRAWING IS A CONDITION PRECEDENT TO THE USE THEREOF. COPYRIGHT OF THIS DRAWING, ITS CONTENT AND
DESIGN ARE RESERVED BY ACUMEN ENGINEERING LTD. THE DRAWING AND THE INFORMATION CONTAINED HEREIN SHALL NOT BE REPRODUCED IN
WHOLE, OR IN PART, WITHOUT PRIOR WRITTEN PERMISSION FROM ACUMEN ENGINEERING LTD.
BY
DATE
REV
DESCRIPTION
-
ISSUED FOR 75% REVIEW
ACUMEN
2015-06-09
-
ISSUED FOR 95% REVIEW
ACUMEN
2015-06-17
-
ISSUED FOR TENDER ONLY
ACUMEN
2015-06-19
CITY OF NEW WESTMINSTER
Council Chambers
EQUIPMENT DETAILS
COUNCIL CHAMBERS
T105
Drawing scale may be affected by printing, scanning or copying.
650-2700 PRODUCTION WAY
BURNABY, BC V5A 4X1
PH.604.676.9545
ACUMENENGINEERING.CA
THIS DRAWING AND ALL ASSOCIATED DOCUMENTS ARE AN INSTRUMENT OF SERVICE AND ARE, AND WILL, AT ALL TIMES REMAIN EXCLUSIVE PROPERTY
OF ACUMEN ENGINEERING LTD. ALL DESIGNS AND OTHER INFORMATION SHOWN ON THIS DRAWING ARE FOR USE ONLY ON THE SPECIFIED PROJECT;
AND MAY BE USED ONLY FOR THE ISSUED PURPOSE AS STATED HEREIN. PAYMENT OF ALL SUMS DUE TO ACUMEN ENGINEERING LTD. UP TO THE DATE
OF THE INTENDED USE OF THIS DRAWING IS A CONDITION PRECEDENT TO THE USE THEREOF. COPYRIGHT OF THIS DRAWING, ITS CONTENT AND
DESIGN ARE RESERVED BY ACUMEN ENGINEERING LTD. THE DRAWING AND THE INFORMATION CONTAINED HEREIN SHALL NOT BE REPRODUCED IN
WHOLE, OR IN PART, WITHOUT PRIOR WRITTEN PERMISSION FROM ACUMEN ENGINEERING LTD.
BY
DATE
REV
DESCRIPTION
-
ISSUED FOR 75% REVIEW
ACUMEN
2015-06-09
-
ISSUED FOR 95% REVIEW
ACUMEN
2015-06-17
-
ISSUED FOR TENDER ONLY
ACUMEN
2015-06-19
CITY OF NEW WESTMINSTER
Council Chambers
AV SCHEMATIC
COUNCIL CHAMBERS
T200
Drawing scale may be affected by printing, scanning or copying.
650-2700 PRODUCTION WAY
BURNABY, BC V5A 4X1
PH.604.676.9545
ACUMENENGINEERING.CA
THIS DRAWING AND ALL ASSOCIATED DOCUMENTS ARE AN INSTRUMENT OF SERVICE AND ARE, AND WILL, AT ALL TIMES REMAIN EXCLUSIVE PROPERTY
OF ACUMEN ENGINEERING LTD. ALL DESIGNS AND OTHER INFORMATION SHOWN ON THIS DRAWING ARE FOR USE ONLY ON THE SPECIFIED PROJECT;
AND MAY BE USED ONLY FOR THE ISSUED PURPOSE AS STATED HEREIN. PAYMENT OF ALL SUMS DUE TO ACUMEN ENGINEERING LTD. UP TO THE DATE
OF THE INTENDED USE OF THIS DRAWING IS A CONDITION PRECEDENT TO THE USE THEREOF. COPYRIGHT OF THIS DRAWING, ITS CONTENT AND
DESIGN ARE RESERVED BY ACUMEN ENGINEERING LTD. THE DRAWING AND THE INFORMATION CONTAINED HEREIN SHALL NOT BE REPRODUCED IN
WHOLE, OR IN PART, WITHOUT PRIOR WRITTEN PERMISSION FROM ACUMEN ENGINEERING LTD.
BY
DATE
REV
DESCRIPTION
-
ISSUED FOR 75% REVIEW
ACUMEN
2015-06-09
-
ISSUED FOR 95% REVIEW
ACUMEN
2015-06-17
-
ISSUED FOR TENDER ONLY
ACUMEN
2015-06-19
CITY OF NEW WESTMINSTER
Council Chambers
AV CONTROL SYSTEM
COUNCIL CHAMBERS
T201
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement