! AT Command Set & Operation Manual V.34 Integrated Data/Fax/Voice/Speakerphone Operation Manual & AT Command Set DM336P DATA/FAX/VOICE MODEM Preliminary Order No. DM336P-002-01 Version : DM336P-AT-P04 AT Command Set Table of Contents Operation Manual Installation Specification Troubleshooting AT Command Set Part I : Data command a. General Command b. V.42bis / MNP 5 Command c. Result Code Part II : Fax Command a. Fax Class 1 Command b. Fax Class 2 Command Part III :Voice Command a. Voice Command b. Shielded Command Part V : S Registers Preliminary 2 Order No. DM336P-002-01 Version : DM336P-AT-P04 AT Command Set Operation manual Specification DM336P provides ISA plug & play function. This function includes two operation modes. One is Win95 mode. The other one is Jumpless mode. User must uses DM336P installation program to setup the COM port when the card is set in Jumpless mode. Installation a. Jumpless mode 1. 2. 3. 4. Open the setting jumper. Put modem card in computer’s slot. Execute Comset.exe Move Bar to “Configuration” and press “Enter” to choose the configuration function 5. Move Bar to “Modify COM port” and press “ Enter” to entry COM port selection mode. 6. Select the COM port and press “ Enter”. 7. Move Bar to “Modify IRQ” and press “Enter” to enter IRQ selection mode. 8. Select the IRQ and press ”Enter”. 9. Move Bar to “Save Configuration” and press “Enter” to save your setting in EEPROM. 10. Quit the installation program. b. Win95 mode 1. 2. 3. Short the setting jumper. Put modem card in computer’s slot. Use the “Control Panel” to setup you modem system. Preliminary 3 z z z z z z z z z z z z CCITT/ITU/Bell Standard: V. 34+, V.34, V.32bis, V32, V22, V21, Bell 103, V.17, V.29, V.21ter MNP 5, 4, 3, 2 Host Interface : ISA bus PnP Fax Group : Group III Fax Command : EIA/TIA-578 Class 2 Voice Command : Davicom Command Escape Command : TIES Transmit Level : -12dbm +/- 1dbm Sensitivity : -35dbm Power : 620mw (Max) Temperature : 0 to 55 Degree C Dial Tone detection : 340Hz - 550Hz Troubleshooting Your modem is designed to provide reliable and trouble-free operation. However, please follow the suggest to solve your problems. Modem does not respond to commands. 1. Using Comset.exe program to set up Com Port again. 2. Run “Diagnostic” to check you modem 3. Use “AT&F&W&W1” as your initialization command. Modem dials but not connect. 1. Make sure the IRQ setting is identical on both the modem AND the software. Make sure the Phone line is working properly. A noisy line will prevent proper modem operation. Order No. DM336P-002-01 Version : DM336P-AT-P04 AT Command Set Preliminary 4 Order No. DM336P-002-01 Version : DM336P-AT-P04 AT Command Set returning to the Command Mode. Please refer to S2 and S12. PART I : Data COMMAND SET General Command A/ AT Repeat the last executed AT command Do not precede A/ with AT or follow with ENTER. Attention Characters. 'AT' character pairs always at the beginning of each command line, except 'A/', which is to repeat the last executed AT command. Note: The following commands always have to precede with 'AT' attention character pair, if it is the first command in the command line. A Manually answer incoming call. D Dial (Originate a Call). The following modifiers can be used in the dial string: 0-9,#,* Dialing digits. Touch Tone dial characters. P Pulse dialing. T Touch Tone dialing. W Wait for second dial tone. , Pause (programmable by S8). ^ Enable 1300 Hz calling tone. ! Flash (delay 500 ms). ; Return to command mode. DS=n Dial stored number. Dials one of three telephone numbers ( n = 0,1 or 2 ) which is stored in the modem's nonvolatile memory via AT&Zn=x command. En E0 E1* Command Echo. Disables command echo. Enables Command echo. +++ Default Escape Character. To switch from data mode to command mode, you can pause one second and type '+++'. Do not follow with carriage return. The default ASCII character '+' is decimal 43. You can change register S2 to any value from 0 to 255. Values greater than 127 disable the escape feature and prevent you from Preliminary 5 Hn H0* H1 Hook control. Modem is on-hook (disconnect from line). Modem is off-hook (connect to line). In I0* I1 I2 I3 I4 Identification. Display product-identification code. Factory set. Internal memory test. Firmware version 1. Firmware version 2. Ln L0 L1 L2* L3 Volume Control. Speaker volume off. Low speaker volume. Medium speaker volume. Loud speaker volume. Mn M0 M1* M2 M3 Speaker Control. Speaker off. Speaker on until carrier detected. Speaker always on. Speaker on until carrier detected and off while dialing. Nn N0 Auto mode Selection. Disable auto mode. Modem connect speed is fixed according to AT*Nn setting. Enable adaptive connect speed (always connect at the highest compatible speed). N1* On O0* O1 Return to Data Mode Selection. Return to Data Mode. Return to Data Mode and initiate a retrain. Qn Q0* Q1 Modem Response Selection. Modem sends responses. Modem does not sends responses. Sr? Reads Register r Value. r is 0 to 97. Sr=n Set Register r to Value n. r is 0 to 97, n is 0 to 255. Un V.34 Control. Order No. DM336P-002-01 Version : DM336P-AT-P04 AT Command Set U0 U1 U2 Disable V.34 when AT*N1 - AT*N6. Enable V.34. Enable V.34 aggressive connection &D1 &D2* Vn V0 V1* Responses Selection. Numeric responses. Verbose (text) responses. Xn X0 X1 Response Set Selection (See table 1). Report basic call progress result codes. Report basic call progress result codes and connections speeds, disable dial tone and busy tone detection. Report basic call progress result codes and connections speeds, disable busy tone detection only. Report basic call progress result codes and connections speeds, disable dial tone detection only. Report all call progress result codes and connection rate. X2 X3 X4* Yn Y0* Y1 Long Space Disconnect Selection. Disables long space disconnect. Modem does not send or respond to long space disconnect. Enables long space disconnect. Modem sends break signal for 4 seconds before disconnect or will disconnect after receiving 1.6 seconds of break from remote modem. &D3 Modem resets following an ON-to-OFF Data Terminal Ready transition and retrieves modem default configuration (Same as ATZ). &F Load Modem Factory Default Configuration Restores the modem to the default operating characteristics. &Gn &G0* &G1 &G2 Guard Tone Selection. Disable guard tone. Enable 550 Hz guard tone. Select 1800 Hz guard tone. &Ln &L0* &L1 Dial-up or Leased-Line Operation Selection. Modem is setup for dialup operation. Modem is setup for 2-wire leased-line operation. Modem is setup for 4-wire leased-line operation. &L2 &Pn &P0* &P1 Zn Z0* Z1 &Cn &C0 &C1* Reset and Profile Retrieve Selection Reset modem and retrieve active configuration profile from stored configuration profile 0. Reset modem and retrieve active configuration profile from stored configuration profile 1. &Rn &R0 &R1 Carrier Output Selection. Keep Data Carrier Detect (DCD) signal always ON. Set Data Carrier Detect (DCD) signal according to remote modem data carrier signal. &R2* &Dn Data Terminal Ready (DTR) Signal Handling. &D0 Modem ignores the Data Terminal Ready signal from host. Preliminary 6 Modem returns to Command Mode and asynchronous operation following an ON-to-OFF Data Terminal Ready transition. Modem hangs up, returns to the Command Mode, and prepares for asynchronous operation following an ON-to-OFF Data Terminal Ready transition. Make/Break Ratio. US setting for off-hook (make) to on-hook (break) ratio. UK and Hong Kong setting for off-hook to on-hook ratio. Clear To Send (CTS) Signal Selection. Modem turns on the Clear To Send signal when it detects the Request To Send (RTS) signal from host. Modem ignores the Request To Send signal and turns on its Clear To Send signal when ready to receive data. Clear To Send force on. &Sn &S0* &S1 Data Set Ready (DSR) Signal Selection. Data Set Ready is forced on. Data Set Ready to operate according to RS232 specification. &Tn &T0* Test Selection. Terminates test in progress. Order No. DM336P-002-01 Version : DM336P-AT-P04 AT Command Set &T1 Performs Local Analog Loopback Test. &V Configuration Profile Display Selection. &Wn &W0* Active Configuration Profile Store Selection. Stores active configuration profile in configuration profile 0. Stores active configuration profile in configuration profile 1. &W1 &Yn &Y0* &Y1* Selection of the Active Configuration After Power-On or Reset. Retrieves configuration profile 0 as the active configuration profile when the Modem is turned on or is reset. Retrieves configuration profile 1 as the active configuration profile when the Modem is turned on or is reset. &Zn=x Store Telephone Numbers in Nonvolatile Memory. Stores three telephone numbers, 31 characters each, in the non-volatile memory. Uses ATDS=n to dial or to use AT&M2 for synchronous data mode. *Gn *G0 *G1* Adaptive Handshake Selection. Disables adaptive protocol handshake. Enables adaptive protocol handshake. *Nn *N0 *N1 *N2 *N3 *N4 *N5 *N6 *N7 *N8 *N9 *N10 *N11 *N12 *N13 *N14* *N15 *N16 *N17 Connect Speed Selection. Selects connect speed 1200bps. Selects connect speed 2400bps. Selects connect speed 4800bps. selects connect speed 7200bps. Selects connect speed 9600bps. Selects connect speed 12000bps. Selects connect speed 14400bps. Selects connect speed 16800bps. Selects connect speed 19200bps. Selects connect speed 21600bps. Selects connect speed 24000bps. Selects connect speed 26400bps. Selects connect speed 28800bps. Selects connect speed 31200bps . Selects connect speed 33600bps . Selects connect speed 1200/75bps. Selects connect speed 300bps (V.21). Selects connect speed 300bps (Bell 103). Preliminary 7 *Pn *P0* *P1 User Abort Selection. Enables user abort feature. Disables user abort feature. *Qn *Q0 *Q1* Auto Retrain Selection. Disables auto retrain. Enables auto retrain. *Tn *T0 *T1* Trellis Coding Selection. Disables Trellis coding. Enables Trellis coding. *Xn *X0* *X1 *X2 *X3 *X4 *X5 *X6 *X7 *X8 *X9 *X10 *X11 *X12 *X13 *X14 *X15 Transmission Level Selection. Selects output level -11dBm. Selects output level -12dBm. Selects output level -13dBm. Selects output level -14dBm. Selects output level -15dBm. Selects output level -16dBm. Selects output level -17dBm. Selects output level -18dBm. Selects output level -19dBm. Selects output level -20dBm. Selects output level -21dBm. Selects output level -22dBm. Selects output level -23dBm. Selects output level -24dBm. Selects output level -25dBm. Selects output level -26dBm. V.42bis / MNP Command Set %An Set Auto-Reliable Fall Back Character Set auto-reliable fall back character to n (n = 0 to 127). \An \A0 \A1 \A2 \A3* MNP Block Size Selection. Selected 64-character maximum block size. Selected 128-character maximum block size. Selected 192-character maximum block size. Selected 256-character maximum block size. \Bn Set Line Break. Send a n/10 seconds line break to the modem (n = 0 to 9). Default = 3. Break length always 300 msec for MNP mode. %Cn %C0 Data Compression. Disables data compression. Order No. DM336P-002-01 Version : DM336P-AT-P04 AT Command Set %C1* Enables data compression. \En \E0* \E1 Normal Mode Data Echo Selection. Disables data echo during a normal link. Enables data echo during a normal link. \Jn \J0* DTE Baud Rate Adjustment Selection. Disables DTE rate adjustment. DTE rate is constant regardless of data link speed. Enables DTE rate adjustment. DTE matches data link speed \J1 \Kn \K0 \K1 \K2 \K3 \K4 \K5* \Nn \N0 \N1 \N2 \N3 \N4 \N5* \N6 \N7 Break Control Selection. Enters the Command Mode, but does not send a Break to remote modem. (To send a Break after use the \B command). Empty data buffers and immediately sends a Break to remote. Same as AT\K0. Immediately send a Break. Same as AT\K0. Send a Break in sequence with any data received from host. Data Link Selection. Selects Normal data link. Selects Direct data link. Selects MNP Reliable link only. Selects MNP Auto-reliable link. Selects V.42 reliable link with phase detection. Selects V.42 auto-reliable link with phase detection. Selects V.42 reliable link without phase detection. Selects V.42 auto-reliable link without phase detection. \Qn \Q0 \Q1 \Q2 \Q3* Flow Control Selection. Disables flow control. Selects XON\XOFF in-band flow control. Selects CTS hardware flow control. Selects RTS\CTS hardware flow control. \Tn Set Inactive Timer. Set inactivity timer to n minutes (n = 0 to 90 ). Default = 0. Preliminary 8 \Vn \V0 \V1* V42/MNP Extended Response Selection. Disables V42/MNP extended responses. Enables V42/MNP extended responses. \Xn \X0* \X1 XON\XOFF Pass-through Selection. Process XON\XOFF and don't pass through. Processes XON\XOFF and pass through. Wn W0 W1* DTE/DCE Speed Response Selection. Display DCE connection rate Display DTE connection rate &Kn &K0 &K3* Flow Control Selection. Disable Local flow control. Selects RTS\CTS hardware flow control. &K4 &K5 Selects XON\XOFF in-band flow control. Selects Transparent XON\XOFF in-band flow control. &Mn &M0 &M5* Data Connection Selection. Selects Direct data link. Instructs the modem to make a data connection using V.42 standard . Result Code (Table 1) Long Form Short Form n value in ATXn 0 1 2 3 4 OK CONNECT RING NO CARRIER ERROR CONNECT 1200 NO DAILTONE BUSY NO ANSWER CONNECT 600 CONNECT 2400 CONNECT 4800 CONNECT 9600 CONNECT 7200 CONNECT 12000 CONNECT 14400 CONNECT 19200 CONNECT 38400 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 20 21 22 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x Order No. DM336P-002-01 Version : DM336P-AT-P04 AT Command Set CONNECT 57600 CONNECT 115200 CONNECT 1200RX/75TX CONNECT 75TX/1200RX RINGBACK CONNECT BELL 300 CONNECT V21 23 24 25 26 27 28 29 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x %TT34 V.25 calling tone (1100) %TT40 V.23 channel 2 %TT41 V.24 ter 2400 bps %TT42 V.27 ter 4800 bps %TT43 V.29 7200 bps %TT44 V.29 9600 bps %TT45 V.17 7200 bps long train %TT46 V.17 7200 bps short train %TT47 V.17 9600 bps long train %TT48 V.17 9600 bps short train %TT49 V.17 12000 bps long train %TT4A V.17 12000 bps short train %TT4B V.17 14400 bps long train %TT4C V.17 14400 bps short train %TT6R,S,A,P V.34 modulation ( Display DCE speed by ATW0 ) CONNECT 16800 CONNECT 19200 CONNECT 21600 CONNECT 24000 CONNECT 26400 CONNECT 28800 CONNECT 31200 CONNECT 33600 15 16 17 21 30 31 32 33 PTT Testing Utilities %TT00 - %TT 09 DTMF tone dial digits 0 to 9. %TT0A DTMF digit *. %TT0B DTMF digit A. %TT0C DTMF digit B. %TT0D DTMF digit C. %TT0E DTMF digit #. %TT0F DTMF digit D. %TT10 V.21 channel 1 mark (originate) %TT11 V.21 channel 2 mark symbol %TT12 V.23 backward channel mark symbol %TT13 V.23 forward channel mark symbol %TT14 V.22 originate (call mark) signal at 600bps %TT15 V.22 originate (call mark) signal at 1200bps %TT16 V.22 bis originate (call mark) signal at 2400bps %TT17 V.22 answer signal (guard tone if PTT require). %TT18 V.22 bis answer signal (guard tone if PTT require). %TT19 V.21 channel 1 space symbol. %TT20 V.32 9600 bps. %TT21 V.32 bis 14400 bps. %TT1A V.21 channel 2 space symbol. %TT1B V.23 backward channel space symbol %TT1C V.23 forward channel space symbol %TT30 Silence (on-line), i.e., go off-hook %TT31 V.25 answer tone %TT32 1800 Hz guard tone %TT33 V.25 calling tone (1300Hz) Preliminary 9 R parameter 1 2 3 4 5 6 7 8 9 A B C D S parameter 1 2 3 Data Rate (bps) 2400 (V.34 only) 4800 (V.34 only) 7200 (V.34 only) 9600 (V.34 only) 12000 (V.34 only) 14400 16800 19200 21600 26400 28800 31200 33600 Symbol Rate (Baud) 2400 Reserved 2800 Order No. DM336P-002-01 Version : DM336P-AT-P04 AT Command Set 4 5 6 A Parameter 0 1 +FAA=1 Enables Auto detection of Data or Fax operations. 3000 3200 3429 +FBOR=n Phase C Data Bit Order Selection. +FBOR=0 Selects direct bit order for both Phase C data and for Phase D data. +FBOR=1 Selects reversed bit order for Phase C data and selects direct bit order for Phase D data. Auxiliary Channel Disable Enable P parameter Amount of upper Band Edge Attenuat Compensated (dB) 0-9 see ITU - V.34 Figures 1,2 and Table 3,4 +FCR= Capability to Receive. +FCR=0 Indicates the DCE will not receive message data. Also the DCE will not be able to poll a remote device. +FCR=1 Indicates the DCE can receive message data. +FDCS=vr, br, wd, ln, df, er, ft, st Set Current Session Parameter. +FDCC=vr, br, wd, ln, df, er, ft, st Set DCE Capabilities Parameters. +FDIS=vr, br, wd, ln, df, er, ft, st Set Current Session Negotiation Parameters. PART II : FAX Command Fax Class 1 Command +FCLASS=n Data or Fax Mode Selection. +FCLASS=0 Selects Data mode operation. +FCLASS=1 Selects Fax Class 1 mode operation. +FDR Receive Data Command. +FDT Transmit Data Command. +FAE=n Data/Fax Auto answer. +FRH=n Recevie data with HDLC framing. +FRM=n Receive data. +FRS=n Receive silence. +FTH=n Transmit data with HDLC framing. +FTM=n Transmit data. +FTS=n Stop Transmit and wait. +FLID=”m” Set Local ID String. 'm' is 20 characters numeric string, set by user, to be used in TSI or CSI frame. +FMDL? Request Model Information. +FMFR? Request Manufacturer Information. +FREV? Request Revision Information. Fax Class 2 Command The Fax class 2 mode Result codes are: +FCLASS=n Data or Fax Mode Selection. +FCLASS=0 Selects Data mode operation. +FCLASS=2 Selects Fax Class 2 mode operation. OK Command valid and executed successfully. ERROR Command error and can not be executed. +FAA=n Fax Auto Answer Mode Selection. +FAA=0 Disables Fax Auto Answer operation Preliminary +FCFR Confirmation to receive prompt. 10 Order No. DM336P-002-01 Version : DM336P-AT-P04 AT Command Set Modem issues the response when detects an acceptable TCF training burst and a valid DCS signal from remote modem. +FCON Facsimile connection response Modem issues the response when detects call progress and fax handshaking is in progress. +FCSI:'m' Report the called station ID response Modem issues this after receiving the remote ID string. +FDCS:vr, br, wd, ln, df, er, ft, st Report session parameters response. +FDIS:vr, br, wd, ln, df, er, ft, st Report remote capabilities response. +FET:<ppr> Post page message response Modem issues this after the end of Phase C reception, on receipt the post page message from the transmitting modem. 0 MPS Another page, same parameters 1 EOM Anther document, new page parameters. 2 EOP No more pages or documents. +FHNG:m Call termination status response Modem issues this to indicate the call has been terminated. +FPTS:<ppr> Page transfer status response Modem issues this indicating the copy quality and related post page message responses received from the remote modem. +FTSI: Report remote station ID Modem issues this after receiving TSI from calling station. Preliminary 11 Order No. DM336P-002-01 Version : DM336P-AT-P04 AT Command Set any CID packet received after the first RING cycle including SDM, MDM, or call waiting packet. #CLS Data, Fax or Voice Mode Selection. #CLS? Returns the current setting of the #CLS. #CLS=0* Selects data mode operation. #CLS=2 Selects fax class 2 command operation. #CLS=8 Selects voice mode operation. #MDL? Request Model Information. #MFR? Request Manufacturer Information. #REV? Request Revision Information. #TL=XXXX Voice Playback Volume Control. #TL=0 mute, means no volume. #TL=1 -24db, low volume #TL=2 -18db #TL=3 -12db #TL=4 -6db #TL=5* -0db #TL=6 +6db #TL=7 +12db #TL=8 +18db, high volume #VBS Bits Per Sample Selection. #VBS? Returns the current setting of #VBS. #VBS=1 Selects 8 bits PCM. #VBS=2 Selects 2 bits per sample ADPCM. #VBS=3 Selects 3 bits per sample ADPCM. #VBS=4* Selects 4 bits per sample ADPCM. PART III : VOICE MODE COMMAND SET Voice Command #BDR Baud Rate Selection. #BDR? Returns the current setting of the #BDR. #BDR=0*Enable autobaud detection. #BDR=n Where n = 1,2,4,6,8,16,24. Sends OK message and switches to the new speed defined by n*2400 bps. #CID #CID #CID=0* #CID=1 Caller ID Selection. Returns the current settings of #CID. Disable Caller ID. Enables formatted Caller ID reporting Single Data Message (SDM) and Multiple Data Message (MDM) packets. #CID=2 Enables unformatted Caller ID reporting of Preliminary 12 #VBT #VBT? Beep Tone Timer. Returns the current setting of the #VBT command. #VBT=0 Disables the tone generation capability #VBT=n Sets tone duration time in 100 msec. Where n = 1-40. Default is 10. #VCI? Request Compression Method Information. #VLS Voice Line Selection. #VLS? Returns the current setting of the #VLS. #VLS=0* This command causes the telephone line Order No. DM336P-002-01 Version : DM336P-AT-P04 AT Command Set interface to be routed through the modem. #VLS=1 This command causes the handset to be routed through the modem. #VLS=2 This command routes the speaker through the modem. #VLS=3 This command routes the auxiliary input device through the modem. #VLS=4 This command is the same as #VLS=0, except the modem enables the internal speaker. #VLS=6 This command enables the microphone and speaker interface, use for speaker phone mode. #VRX #VTX Set Voice Receive Mode This action command is only valid if the modem is in the on-line voice command mode. Set Voice Transmit Mode This action command is only valid if the modem is in the on-line voice command mode. <DLE>0-9 DTMF digits 0 through 9 <DLE>*,# DTMF digits *, # <DLE>A-D DTMF A through D <DLE>a Answer Tone detected,V.35/T30 2100Hz answer tone is detected. <DLE>b Busy, The busy cadence is detected. <DLE>c Calling Tone, T.30 1100Hz Calling tone is Detected. <DLE>d Dial Tone, The Dial tone is detected. <DLE>e European Calling Tone, V.25 1300Hz Calling Tone is detected. <DLE>f Bell Answer Tone , Bell 2225Hz Answer tone is detected. Voice mode Result codes OK Command valid and executed successfully. ERROR Command error and can not be executed. VCON Issued in Voice mode (#CLS=8) when the modem determines that the remote modem or handset has gone off-hook, or when returning to on-line voice command mode. NO ANSWER Issued in Voice mode (#CLS=8) when the modem determines that the remote modem has not picked up the line after the S7 timer has expired. CONNECT When Voice transmission by DTE can begin. Voice mode Shielded codes Preliminary 13 Order No. DM336P-002-01 Version : DM336P-AT-P04 AT Command Set Register S1 : Count Incoming Rings. The S1 register records the number of incoming rings. Reset to 0 after 8 seconds of no ring. Register S2 : Value of the Escape Character. Register S2 sets the ASCII value in decimal of the escape character. The default value (decimal 43) is equivalent to the ASCII character '+'. You can change this register to any value from 0 to 255. Values greater than 127 disable the escape feature. Register S3 : Value of the Carriage Return Character. Register S3 sets the ASCII value in decimal of the carriage return character (End-Of-Line). The default value is 13. You can change it to any ASCII value between 0 and 127. Register S4 : Value of the Line Feed Character. Register S4 sets the ASCII value in decimal of the line feed character. The default value is 10. You can change it to any ASCII value between 0 and 127. If you do not want to receive a line feed character, you can change the value in this register to a null character, but you cannot disable line feed characters. Register S5 : Value of the Backspace Character Register S5 sets the ASCII value in decimal of the backspace character. This character is the character created by pressing BACKSPACE key and the characters echo to host are BACKSPACE, SPACE, BACKSPACE ( i.e. move the cursor to the left ). The default value is 8. You can change it to any ASCII value between 0 and 32, or 127. Note: Do not set the value of the backspace character between 33 and 126. PART V: S Registers Register S0 : Auto Answer Ring. Register S6 : Dial Tone Wait Time. Assigning a value from 1 to 255 in Register S0 tells the modem the number of rings that must occur before it can automatically answer incoming calls. The default value = 0 ( no Auto Answer). Preliminary 14 Register S6 sets the time to wait after going off-hook before dialing the first digit in a Dial command when using the X0, X1 or X3 responses. The default time is 2 Order No. DM336P-002-01 Version : DM336P-AT-P04 AT Command Set seconds, although you can change it to any value between 2 and 255 seconds. This feature is convenient when it takes longer than 2 seconds to obtain a dial tone. status and act as if the remote modem's carrier signal is always present, set the value to 255. Register S7 : Remote Carrier Signal Wait Time. Register S11 controls the speed of the Touch Tone (DTMF) dialing. You can change the value from 50 to 255 ms. The default value will be 95 ms which sets a dialing rate of 5.26 digits per second. Increasing the value to 255 slows the dialing rate to 1.9 digits per second. Register S11 : Touch Tone Dialing Duration. Register S7 decides how many seconds to wait for a remote modem's carrier signal before hanging up. The default value is 45 seconds. You can change it to a value between 1 and 255 seconds. Register S7 also controls the time-out of the W command. Note : Register S11 has no effect on pulse dialing, which is fixed at 10 pulses per second. Register S8 : Pause Time for Comma Register S8 decides how many seconds to pause for each comma ( , ) encountered in a Dial command line. You usually use the comma when dialing through a PBX or other special telephone services to wait for an outside telephone line. The default value is 2 seconds, although you can change it to a value between 0 and 255 seconds. An alternative to changing this register is to include more than one comma in your command line. Register S9 : Carrier Detect Response Time. Register S9 sets the time the remote modem's carrier signal must be present for the local modem to recognize it. This feature ensures that your modem does not mistake a busy signal, ring, or voice for the carrier signal. The value of this register is in tenths of a second. The default value is 600 ms , although you can change it from 1 to 255. For example, entering a value 13 means that the remote modem's carrier signal must be present for 1.3 seconds for the local modem to recognize it. Setting this value higher increases the chances the modem will not mistakenly identify the carrier signal. Register S10 : Carrier Loss Time. Register S10 sets the time between the loss of a remote modem's carrier signal and when the local modem disconnects. This allows the remote modem's carrier signal to momentarily disappear from the telephone line. The value of this register is in tenths of a second. The default value is 1.4 seconds, although you can change it from 1 to 255. You may want to set this value higher if you have a noisy telephone line that might interfere with the remote modem's carrier signal. If you want your modem to ignore the Carrier Detect Preliminary 15 Register S12 : Escape Guard Time. Register S12 controls the escape guard time ( i.e. the time delay required before and after you enter the escape characters). The guard time prevents your modem from misinterpreting data as the escape sequecce. This value is designated in measurements of 20 ms. The default value is 50 ( which is equivalent to one second), although you can change it to between 0 (0 seconds) to 255 (5.1 seconds). Register S14 : Bit-mapped Register. Bit-mapped register S14 lets you control modem echo, responses, dialing method, and the originate or answer mode. Bit 0= x Function Undefined. 1= 0 1 Do not echo command (E0). Echo command (E1) – default. 2= 0 1 Responses appear (Q0) – default. Responses do not appear (Q1). 3= 0 1 Numeric responses (V0). Verbose (Verbal) Responses (V1) – default. 4= x Undefined. 5= 0 1 6= x Use touch-tone dialing method (T) – default. Use pulse dialing method (P). Undefined 7= 0 Answer incoming calls (A) Order No. DM336P-002-01 Version : DM336P-AT-P04 AT Command Set 1 Originate calls (D) -- default Register S16 : Modem Tests. Bit-mapped register S16 displays the modem tests status. Bit Function 0= 0 Local analog loop back test off (&T0) – default. Local analog loop back test on (&T1). 1 1= x Register S22 : Bit-mapped Register Bit-mapped register S22 lets you control internal speaker and the modem responses. Bit Function ------------------------------------------------------0,1= 0 Speaker volume off (L0). 1 Low speaker volume (L1). 2 Medium speaker volume (L2) – default. 3 Loud speaker volume (L3). Undefined. Register S18 : Duration of Modem Test. Register S18 sets the amount of time for the modem tests. The tests can run from 1 to 255 seconds, depending on the value in this register. This register has a default value of 0, which turns off the timer and tests will run until manually terminated. 2,3= 0 1 2 3 Speaker off (M0). Speaker on until carrier detected (M1) – default. Speaker always on (M2). Speaker on until carrier detected but off during dialing (M3). Register S21 : Bit-mapped Register. Bit-mapped register S21 lets you control certain data communication control signals. Bit 4,5,6=0 4 5 6 Hayes™ Smartmodem compatibility (X0). Include CONNECT XXX responses (X1). Same as 4 plus dial tone detection (X2). Same as 4 plus BUSY response and blind dialing (X3). 7 Same as 6 plus dial tone detection (X4) – default. Function 0,1 = x Undefined. 2= x Undefined. 7= 0 1 3,4= 0 Modem ignores the DTR signal (&D0). 1 Modem enters command mode after ON-toOFF DTR transition (&D1). 2 Modem hangs up after ON-to-OFF DTR transition (&D2) – default. 3 Modem resets after ON-to-OFF DTR transition (&D3). 5= 0 1 6= x 7= 0 1 CD signal always on (&C0). CD signal on when a remote carrier signal is present (&C1) – default. Undefined. Preliminary Register S23 : Bit-mapped Register. Bit 1,2,3= 0 2 3 4 5 6 7 4,5= 0 1 2 3 6,7= 0 Long space disconnect turned off (Y0) – default. Long space disconnect turned on (Y1). 16 US make/break ratio (&P0) – default. UK and Hong Kong make/break ratio (&P1). Function Use 0-300bps DTE data rate. Use 1200bps DTE data rate. Use 2400bps DTE data rate. Use 4800bps DTE data rate. Use 9600bps DTE data rate. Use 19200bps DTE data rate. Use 38400bps or above DTE data rate. Use even parity. Use space parity. Use odd parity. Use mark or none parity. Turn off guard tone (&G0) – default. Order No. DM336P-002-01 Version : DM336P-AT-P04 AT Command Set 1 Turn off guard tone (&G1). 2 Use 1800 HZ guard tone (&G2). When there is an inactivity time out with #CLS=8, the modem always forces #CLS=0 and #BDR=0. Register S36 : V.42 negotiation fallback. Register S25 : Data Terminal Ready Delay. When Modem is on-line, it will ignore a Data Terminal Ready signal lasting less than the value of this register. In this mode, the values for this register are 0 to 255 in hundredths of a second, and the default value is 0.05 seconds. If you will be entering synchronous mode after dialing asynchronously, this register determines how long the modem waits before looking for the Data Terminal Ready signal. This lets you detach the asynchronous terminal and connect a synchronous terminal while remaining in the Data Mode. In this mode, the values for this register are from 0 to 255 seconds and the default value is 5. Register S36 defines the type of connection attempted by the modem and the action to take if the attempt fails: Bit 2,1,0 = 0 1 2 3 4 5 Register S26 : Request To Send-to-Clear To Send Delay. This register affects synchronous operation only and applies only when you are using the &R0 command. This register determines how long the modem waits to turn on the Clear To Send signal after a Request To Send OFF-to-ON transition in 10 ms increment. The default value is 1, although this register accepts values from 0 to 255. 6 7 Value Function Modem hangs up. Same as 5. Reserved. Same as 7. Modem tries to connect using V.42 Alternative Protocol (compatible with MNP levels 2 - 5 ). If handshaking fails, modem hangs up. Modem tries to connect using V.42 Alternative Protocol compatible with MNP levels 2 - 5 ). If handshaking fails, modem tries to connect using a standard asynchronous connection. Reserved. Modem tries to connect using V.42 Alternative Protocol (compatible with MNP levels 2 - 5 ). If handshaking fails, modem tries to connect using a standard asynchronous connection and automatic speed buffering -- default. Register S27 : Bit-mapped Register. Register S46 : Protocol selection. Bit-mapped register S27 lets you control modem transmission mode and line type. Bit Register S46 defines the protocol selections specified for future negotiation. Function 0 0 : Dial up line (&L0) – default. 1 : 2W Leased line (&L1). 1-7 Undefined. Value 136 138 Function LAP-M only. LAP-M with adaptive data compression – default. Register S82 : Break handling Register S30: Value of the voice inactivity timer. S30 = 0 Voice inactivity timer off (default). S30 = 1 - 255 This is the period of time (in sec), which if expired causes the modem to hang up the telephone line if it is offhook and no data has passed during the period. Preliminary 17 Register S82 specifies the break signal method used during V.42 applications. The break type to be used depends on the user application. Value 3 Function Expedited break signaling, regardless of its Order No. DM336P-002-01 Version : DM336P-AT-P04 AT Command Set 7 128 sequence in data sent and received by each modem. Data integrity maintained both ahead of and after the break. Destructive break signaling, regardless of its sequence in data sent and received by each modem. Data not being processed by each modem at time of break is discarded. In sequence break signaling as data is sent and received. Data integrity is maintained both ahead of and after the break. – default. Register S95 : Negotiation message options. < 32 ≥ 32 Disable V.42 extended response. Enable V.42 extended response. Register S96 : Dial tone/busy tone detect range select. VALUE RANGE ( Hz ) 0 350 - 620 1 2 3 4 425 - 450 440 - 700 350 - 450 375 - 475 5 6 7 8 9 10 150 - 450 270 - 320 350 - 500 375 - 550 350 - 440 110 - 700 COUNTRY USA, KOREA, TAIWAN, --default. BELGIUM. FRANCE. ISRAEL, JAPAN. ITALY, NORWAY, GERMANY, DENMARK. NETHERLANDS. SINGAPORE. SWEDEN. SWITZERLAND. UK. FULL RANGE. Register S97 : Energy detection threshold This register can use in Call Progress Mode (CPM) mode, for dial tone detect threshold. The default value is 2. This register determine the detection threshold for Call Progress (CPM) tones. The default value is 2. Preliminary 18 Order No. DM336P-002-01 Version : DM336P-AT-P04
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement