3000 User Operating Instructions

Add to my manuals
2 Pages

advertisement

3000 User Operating Instructions | Manualzz

3000

Electronic Entry Device

USER OPERATING INSTRUCTIONS

FEATURES

See Manager Instructions for additional features.

USER Combination

• Open Lock

• Change Combination

WRONG TRY PENALTY

• Four (4) consecutive invalid combination

initiates five (5) minute delay period.

LOW BATTERY WARNING

• Repeated LED flashing and beeping during

opening indicates battery is low and needs

immediate replacement.

AUDIO AND VISUAL SIGNAL

• Double signal - two (2) LED flashes and two

(2) beeps - indicates entry is valid

or accepted.

• Triple signal - three (3) LED flashes and

three (3) beeps - indicates invalid or

not accepted.

OPENING THE LOCK

1. Enter valid six (6) digit combination (factory set to 1-2-3-4-5-6).

2. The lock will confirm a valid combination entry with a double signal.

3. Within four (4) seconds, turn the handle to the open position.

4. Pull door open.

Invalid Combination Entry - Lock will signal three (3) times.

WRONG TRY PENALTY

• Entry of four (4) consecutive invalid combinations starts a five (5) minute

delay period.

- LED flashes red at ten (10) second intervals.

• At the end of the delay period, two (2) more consecutive invalid combinations

will restart the five (5) minute delay period.

NOTE: Entry will not respond to keystrokes during delay period.

(P/N) 750.118 Rev B 02/12 • © copyright 2006-2012 Kaba Mas LLC

Page 1 of 2

CHANGING YOUR Combination

ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN

1. Enter “zero” six times.

2. Enter your existing six (6) digit combination one time.

3. Enter your NEW six (6) digit combination two times.

4. If a mistake is made wait thirty (30) seconds and repeat steps 1 - 3.

5. Test lock operation several times before closing the door.

CAUTION: When selecting a combination do not use birthday or other predictable data that could give correlation between the user and combination. Keep the combination secret.

Valid Combination Entry - Double signal after valid six (6) digit combination

is entered.

Invalid Combination Entry - Triple signal indicates the old combination is

still valid.

BATTERY LOW WARNING

• Repeated LED flashing and beeping during an

opening indicates that the battery is low and needs

immediate replacement.

• Uses two (2) 9-Volt alkaline batteries only. (Example:

Duracell™ or Eveready™ alkaline batteries.) It is

recommended that batteries be replaced at least

once a year.

If battery is depleted and will not allow lock to open, follow Instructions below. Lock contains a nonvolatile memory; even with batteries removed, the lock will retain all programming.

CHANGING YOUR BATTERY

1. Slide the keypad housing up and carefully pull away

from mounting surface to expose battery compartment.

2. Remove the two (2) old 9-Volt alkaline batteries.

3. Remove the connector by unsnapping it from

the two terminals on the top of the battery.

CAUTION: Hold onto battery terminal connector to avoid pulling the wires out of housing.

4. Press and hold the zero (0) key for ten (10) seconds

before installing the two (2) new batteries.

5. Carefully position the keypad over the mounting screws and slide the keypad

housing down. Ensure there are no wires or cables trapped between the input pad

and the safe door. Pinched cables can result in a short circuit.

Mounting Instructions available at www.kaba-mas.com.

(P/N) 750.118 Rev B 02/12 • © copyright 2006-2012 Kaba Mas LLC

Page 2 of 2

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement