emc test report
EMC TEST REPORT
EN 301 489-7
"Electromagnetic Compatibility for radio equipment and services – mobile and portable radio and
ancillary equipment of digital cellular radio telecommunications systems (GSM and DCS)"
Report Reference No. ..................... :
G0M-1206-2043-EU01-V01
Testing Laboratory ......................... :
Eurofins Product Service GmbH
Address ............................................. :
Storkower Str. 38c
15526 Reichenwalde
Germany
Accreditation ..................................... :
DAkkS - Registration number : D-PL-12092-01-01
Applicant’s name ............................ :
Falcom Wireless Communications GmbH
Address ............................................. :
Gewerbering 6
98704 Langewiesen
GERMANY
Test specification:
In accordance with customer requests
Standard ........................................... :
EN 301 489-7 V1.3.1:2005-11
EN 301 489-1 V1.8.1:2008-04
Non-standard test method…………..:
None
Test scope………….. ........................ :
complete EMC compliance test
Equipment under test (EUT):
Product description. .......................... :
Tracking Solution
Model No. ......................................... :
FOX-EN
Hardware Version ............................. :
Rev 02c
Software / Firmware Version ............ :
10.00.003
Test result
Passed
Test Report No.: G0M-1206-2043-EU01-V01
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 1 of 32
REPORT INDEX
1
EQUIPMENT (TEST ITEM) DESCRIPTION
4
1.1
Equipment photos
5
1.2
Input / Output Ports
7
1.3
Supporting Equipment Used During Testing
8
1.4
Test Equipment Used During Testing
9
1.5
EUT Operation Modes
11
1.6
Immunity Performance Criteria
12
2
RESULT SUMMARY
14
3
TEST CONDITIONS AND RESULTS
15
3.1
Test Conditions and Results – Radiated emissions
15
3.2
Test Conditions and Results – Conducted emissions
23
3.3
Test Conditions and Results – Immunity to RF electromagnetic fields
27
3.4
Test Conditions and Results – Immunity to conducted disturbances
29
3.5
Test Conditions and Results – Transients and surges in the vehicular environment
31
Test Report No.: G0M-1206-2043-EU01-V01
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 3 of 32
1
Equipment (Test item) Description
Description
Tracking Solution
Model
FOX-EN
Serial number
30580(113)26200001
Hardware version
Rev 02c
Software version
10.00.003
Manufacturer
FMO Electronics GmbH
In den Folgen 39
98704 Langewiesen
GERMANY
Ratings / Power supply
12 VDC (Vehicle battery)
Number of tested samples
1
Equipment classification
EN 301 489-1
vehicular use, tabletop
Equipment classification
EN 301 489-7
GSM/GRPS 900/1800 Transceiver
Equipment without analogue speech equipment
Protective Earth / Ground
No
Test Report No.: G0M-1206-2043-EU01-V01
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 4 of 32
1.1
Equipment photos
EUT TOP
EUT BOTTOM
Test Report No.: G0M-1206-2043-EU01-V01
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 5 of 32
EUT SIDE VIEW
EUT ANTENNA
Test Report No.: G0M-1206-2043-EU01-V01
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 6 of 32
1.2
Input / Output Ports
Port #
Name
Type*
Max. Cable
Length
0
Cable harness
DC / I/O
1.5m
1
RS232
I/O
1.5m
2
GSM/GPS Antenna
I/O
2.5m
Cable
Shielded
Comments
yes
*Note: Use the following abbreviations:
AC : AC power port
DC : DC power port
N/E : Non electrical
I/O : Signal input or output port
TP : Telecommunication port
Test Report No.: G0M-1206-2043-EU01-V01
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 7 of 32
1.3
Supporting Equipment Used During Testing
Product
Type*
Device
Manufacturer
Model No.
SIM
Radio communication
tester
Rohde & Schwarz
CMU200
AE
Laptop
Dell
Latitude D430
Comments
*Note: Use the following abbreviations:
AE : Auxiliary/Associated Equipment, or
SIM : Simulator (Not Subjected to Test)
CABL : Connecting cables
Test Report No.: G0M-1206-2043-EU01-V01
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 8 of 32
1.4
Test Equipment Used During Testing
Measurement Software
Description
Manufacturer
Name
Version
EMC Software
Dare Instruments
Radimation
5.8.20
Software
EM-Test
ISO.Control
5.0.7
Radiated emissions
Description
Manufacturer
Model
Identifier
Cal. Date
Cal. Due
Biconical Antenna
R&S
HK 116
EF00012
2010-01
2013-01
LPD Antenna
R&S
HL 223
EF00187
2011-02
2014-02
LPD Antenna
R&S
HL 025
EF00327
2010-02
2013-02
Spectrum Analyzer
R&S
FSEB
EF00124
2012-07
2013-07
EMI Test Receiver
R&S
ESCS30
EF00297
2011-11
2012-11
Conducted emissions
Description
Manufacturer
Model
Identifier
Cal. Date
Cal. Due
Current probe
R&S
EZ-17
EF00215
2011-11
2013-11
Absorbing Clamp
R&S
MDS 21
EF00035
2009-10
2014-10
ISN
R&S
ENY41
EF00255
2012-04
2014-04
AMN
R&S
ESH2-Z5
EF00182
2010-09
2012-09
LISN
Schwarzbeck
NNBM 8125
EF00040
2012-06
2014-06
LISN
Schwarzbeck
NNBM 8126D
EF00041
2011-05
2013-05
CDN
Teseq
ST08AS
EF00411
2011-09
2013-09
AMN
R&S
ESH3-Z5
EF00036
2010-11
2012-11
EMI Test Receiver
R&S
ESCS 30
EF00297
2011-11
2012-11
Radiated immunity
Description
Manufacturer
Model
Identifier
Cal. Date
Cal. Due
Generator
R&S
SMHU
EF00185
2012-04
2014-04
Amplifier
Amplifier
Research
150W1000
EF00068
System
calibration
System
calibration
Amplifier
Amplifier
Research
60S1G3
EF00270
System
calibration
System
calibration
Antenna
Frankonia
BTA-H
EF00294
System
calibration
System
calibration
Horn antenna
Schwarzbeck
BBHA 9120C
EF00018
2010-08
2013-08
Millivoltmeter
R&S
URV55
EF00216
2012-06
2013-06
Power Sensor
R&S
NRV-Z2
EF00237
-
-
Directional Coupler
MEB
RK100
EF00099
System
calibration
System
calibration
Test Report No.: G0M-1206-2043-EU01-V01
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 9 of 32
Directional Coupler
Narda
3002-20
EF00295
System
calibration
System
calibration
EMI Receiver
R&S
ESCS30
EF00076
2011-12
2013-12
Conducted immunity
Description
Manufacturer
Model
Identifier
Cal. Date
Cal. Due
EMI Test Receiver
R&S
ESCS 30
EF00297
2011-11
2012-11
Generator
R&S
SMG
EF00130
2011-07
2012-07
Amplifier
Amplifier
Research
75A250
EF00191
System
calibration
System
calibration
EM Injection
Clamp
FCC / EMC
F203I
EF00056
2012-04
2017-04
Directional Coupler
Amplifier
Research
DC3001
EF00238
System
calibration
System
calibration
CDN
MEB
M2
EF00331
System
calibration
System
calibration
Transients and surges in the vehicular environment
Description
Manufacturer
Model
Identifier
Cal. Date
Cal. Due
Ultra Compact
Simulator
EM-Test
UCS200M
EF00145
2011-11
2013-11
Voltage Drop
Simulator
EM-Test
VDS200
EF00147
2011-11
2013-11
Capacitive
Coupling Clamp
EM-Test
ACC
EF00644
system
calibration
system
calibration
Injection Clamp
FCC
F-140
EF00239
system
calibration
system
calibration
Test Report No.: G0M-1206-2043-EU01-V01
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 10 of 32
1.5
Mode #
EUT Operation Modes
Description
Active GPRS900 / 2 Timeslot connection to communication tester
1
Monitored parameters (Immunity testing): Link maintenance / Receive quality
Test Report No.: G0M-1206-2043-EU01-V01
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 11 of 32
1.6
Immunity Performance Criteria
The test results shall be classified in terms of the loss of function or degradation of performance of the
equipment under test, relative to a performance level defined by its manufacturer or the requestor of
the test, or agreed between the manufacturer and the purchaser of the product.
Definition related to the performance level:
based on the used product standard
based on the declaration of the manufacturer, requestor or purchaser
Criterion for continuous phenomena according to EN 301 489-7:
Mode
Acceptable level of performance
Transmitter (CT)
A communication link shall be established at the start of the test, and maintained
during the test.
At the conclusion of the test, the EUT shall operate as intended with no loss of
user control functions or stored data, and the communication link shall have been
maintained. In addition to confirming the above performance during a call, the
test shall also be performed in idle mode, and the transmitter shall not
unintentionally operate.
Receiver (CR)
A communications link shall be established at the start of the test.
During the test, the RXQUAL of the downlink shall not exceed the value of three,
measured during each individual exposure in the test sequence.
At the conclusion of the test, the EUT shall operate as intended with no loss of
user control functions or stored data, and the communication link shall have been
maintained.
Test Report No.: G0M-1206-2043-EU01-V01
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 12 of 32
Criterion for transient phenomena according to EN 301 489-7:
Mode
Acceptable level of performance
Transmitter (TT)
A communications link shall be established at the start of the test.
At the conclusion of each exposure the EUT shall operate with no user noticeable
loss of the communication link.
At the conclusion of the total test comprising the series of individual exposures,
the EUT shall operate as intended with no loss of user control functions or stored
data, as declared by the manufacturer, and the communication link shall have
been maintained.
In addition to confirming the above performance during a call, the test shall also
be performed in idle mode, and the transmitter shall not unintentionally operate.
Receiver (TR)
A communications link shall be established at the start of the test.
At the conclusion of each exposure the EUT shall operate with no user noticeable
loss of the communication link.
At the conclusion of the total test comprising the series of individual exposures,
the EUT shall operate as intended with no loss of user control functions or stored
data, as declared by the manufacturer, and the communication link shall have
been maintained.
Test Report No.: G0M-1206-2043-EU01-V01
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 13 of 32
2
Result Summary
EN 301 489-7, EN 301 489-1
Product Specific
Standard
Requirement – Test
Reference
Method
Result
EN 55016-2-3:2006
PASS
EN 55022:2006
PASS
EN 61000-3-2/A1:2006
N/R
See EN 61000-3-2
section 7
See EN 61000-3-3
section 6.1
EN 301 489-7
Section 7.1
Radiated emissions of enclosure of ancillary
equipment measured on a standalone basis
EN 301 489-7
Section 7.1
Conducted emissions
EN 301 489-7
Section 7.1
Harmonic current emissions
EN 301 489-7
Section 7.1
Voltage fluctuations and flicker
EN 61000-3-3:1995
N/R
EN 301 489-7
Section 7.2
Radio frequency electromagnetic field
EN 61000-4-3:2006
PASS
EN 301 489-7
Section 7.2
Radio frequency, common mode
EN 61000-4-6:2005
PASS
EN 301 489-7
Section 7.2
Electrostatic discharge
EN 61000-4-2:2001
N/R
EN 301 489-7
Section 7.2
Fast transients, common mode
EN 61000-4-4:2004
N/R
EN 301 489-7
Section 7.2
Transients and surges in the vehicular
environment
ISO 7637-2:2004
PASS
EN 301 489-7
Section 7.2
Surges
EN 61000-4-5:2006
N/R
EN 301 489-7
Section 7.2
Voltage dips and interruptions
EN 61000-4-11:2004
N/R
Remarks
Remarks:
Test Report No.: G0M-1206-2043-EU01-V01
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 14 of 32
3
3.1
Test Conditions and Results
Test Conditions and Results – Radiated emissions
Radiated emissions acc. to EN 301 489-7
Verdict: PASS
Laboratory Parameters:
Required prior to the test
During the test
Ambient Temperature
15 to 35°C
23°C
Relative Humidity
30 to 60%
45%
Test according to referenced
standards
Common Part
Reference Method
EN 301 489-1
EN 55016-2-3
Fully configured sample scanned
over the following frequency range
Frequency range
EUT operating mode
1
30MHz to 6GHz
Limits and results
Frequency [MHz]
Quasi-Peak [dBµV/m] Result
Average [dBµV/m]
Result Peak [dBµV/m] Result
30 – 230
30
PASS
-
-
-
-
230 – 1000
37
PASS
-
-
-
-
1000 – 3000
-
-
50
PASS
70
PASS
3000 – 6000
-
-
54
PASS
74
PASS
Comments:
Test Report No.: G0M-1206-2043-EU01-V01
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 15 of 32
Test setup
Test Report No.: G0M-1206-2043-EU01-V01
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 16 of 32
Spurious emissions under normal conditions according to EN 301 489
Project number: G0M-1206-2043
Manufacturer:
EUT Name:
Model:
Test Site:
Operator:
Test Conditions:
Antenna:
Measurement distance:
Mode:
Test Date:
Note:
Falcom Wireless Communication GmbH
Tracking Solution
FOX-EN
Eurofins Product Service GmbH
Mr. Handrik
Tnom: 23°C, Unom: 13,5 V DC
Rohde & Schwarz HK 116, Vertical
3m, converted to 10m
GSM 900 (GPRS 2 Slots)
12.07.2012
Index 3
50
EN 55022 Class B QP
RBW: 120 kHz, Vertical Max Peak
45
40
35
Electrical Field (dBµV/m)
30
25
20
15
10
5
0
-5
-10
30 M
40 M
60 M
80 M
100 M
120 M
140 M
160 M
200 M
Frequency (Hz)
Test Report No.: G0M-1206-2043-EU01-V01
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 17 of 32
Spurious emissions under normal conditions according to EN 301 489
Project number: G0M-1206-2043
Manufacturer:
EUT Name:
Model:
Test Site:
Operator:
Test Conditions:
Antenna:
Measurement distance:
Mode:
Test Date:
Note:
Falcom Wireless Communication GmbH
Tracking Solution
FOX-EN
Eurofins Product Service GmbH
Mr. Handrik
Tnom: 23°C, Unom: 13,5 V DC
Rohde & Schwarz HK 116, Horizontal
3m, converted to 10m
GSM 900 (GPRS 2 Slots)
12.07.2012
Index 4
50
EN 55022 Class B QP
RBW: 120 kHz, Horizontal Max Peak
45
40
35
Electrical Field (dBµV/m)
30
25
20
15
10
5
0
-5
-10
30 M
40 M
60 M
80 M
100 M
120 M
140 M
160 M
200 M
Frequency (Hz)
Test Report No.: G0M-1206-2043-EU01-V01
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 18 of 32
Spurious emissions under normal conditions according to EN 301 489
Project number: G0M-1206-2043
Manufacturer:
EUT Name:
Model:
Test Site:
Operator:
Test Conditions:
Antenna:
Measurement distance:
Mode:
Test Date:
Note:
Falcom Wireless Communication GmbH
Tracking Solution
FOX-EN
Eurofins Product Service GmbH
Mr. Handrik
Tnom: 23°C, Unom: 13,5 V DC
Rohde & Schwarz HL 223, Vertical
3m, converted to 10m
GSM 900 (GPRS 2 Slots)
12.07.2012
Index 5
50
EN 55022 Class B QP
RBW: 120 kHz, Vertical Max Peak
45
40
Electrical Field (dBµV/m)
35
30
25
20
15
10
5
0
200 M
300 M
400 M
500 M
600 M
700 M
800 M
1000 M
Frequency (Hz)
Test Report No.: G0M-1206-2043-EU01-V01
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 19 of 32
Spurious emissions under normal conditions according to EN 301 489
Project number: G0M-1206-2043
Manufacturer:
EUT Name:
Model:
Test Site:
Operator:
Test Conditions:
Antenna:
Measurement distance:
Mode:
Test Date:
Note:
Falcom Wireless Communication GmbH
Tracking Solution
FOX-EN
Eurofins Product Service GmbH
Mr. Handrik
Tnom: 23°C, Unom: 13,5 V DC
Rohde & Schwarz HL 223, Horizontal
3m, converted to 10m
GSM 900 (GPRS 2 Slots)
12.07.2012
Index 6
50
EN 55022 Class B QP
RBW: 120 kHz, Horizontal Max Peak
45
40
Electrical Field (dBµV/m)
35
30
25
20
15
10
5
0
200 M
300 M
400 M
500 M
600 M
700 M
800 M
1000 M
Frequency (Hz)
Test Report No.: G0M-1206-2043-EU01-V01
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 20 of 32
Spurious emissions under normal conditions according to EN 301 489
Project number: G0M-1206-2043
Manufacturer:
EUT Name:
Model:
Test Site:
Operator:
Test Conditions:
Antenna:
Measurement distance:
Mode:
Test Date:
Note:
Falcom Wireless Communication GmbH
Tracking Solution
FOX-EN
Eurofins Product Service GmbH
Mr. Handrik
Tnom: 23°C, Unom: 13,5 V DC
Rohde & Schwarz HL 025, Vertical
3m
GSM 900 (GPRS 2 Slots)
12.07.2012
Index 8
80
EN 55022 Class B AV
EN 55022 Class B PK
RBW: 1000 kHz, Vertical Max Peak
RBW: 1000 kHz, Vertical Max Average
70
2
60
Electrical Field (dBµV/m)
1
50
40
30
20
10
0
1000 M
2,0 G
3,0 G
4,0 G
5,0 G
6,0 G
Frequency (Hz)
Frequency
1,805 GHz
2,708 GHz
second harmonics
third harmonics
Test Report No.: G0M-1206-2043-EU01-V01
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 21 of 32
Spurious emissions under normal conditions according to EN 301 489
Project number: G0M-1206-2043
Manufacturer:
EUT Name:
Model:
Test Site:
Operator:
Test Conditions:
Antenna:
Measurement distance:
Mode:
Test Date:
Note:
Falcom Wireless Communication GmbH
Tracking Solution
FOX-EN
Eurofins Product Service GmbH
Mr. Handrik
Tnom: 23°C, Unom: 13,5 V DC
Rohde & Schwarz HL 025, Horizontal
3m
GSM 900 (GPRS 2 Slots)
12.07.2012
Index 7
80
EN 55022 Class B AV
EN 55022 Class B PK
RBW: 1000 kHz, Horizontal Max Peak
RBW: 1000 kHz, Horizontal Max Average
70
60
1
Electrical Field (dBµV/m)
2
50
40
30
20
10
0
1000 M
2,0 G
3,0 G
4,0 G
5,0 G
6,0 G
Frequency (Hz)
Frequency
1,805 GHz
2,707 GHz
second harmonics
third harmonics
Test Report No.: G0M-1206-2043-EU01-V01
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 22 of 32
3.2
Test Conditions and Results – Conducted emissions
Conducted emissions acc. to EN 301 489-7
Verdict: PASS
Laboratory Parameters:
Required prior to the test
During the test
Ambient Temperature
15 to 35°C
23°C
Relative Humidity
30 to 60%
45%
Test according to referenced
standards
Common Part
Reference Method
EN 301 489-1
EN 55022
Frequency range
Fully configured sample scanned
over the following frequency range
0.15MHz to 30MHz
Points of Application
Application Interface
Power
LISN
EUT operating mode
1
Limits and results – AC Mains
Frequency [MHz]
Quasi-Peak [dBµV]
Result
Average [dBµV]
Result
0.15 to 0.5
66 – 56
PASS
56 – 46
PASS
0.5 to 5
56
PASS
46
PASS
5 to 30
60
PASS
50
PASS
Comments:
The limit decreases linearly with the logarithm of the frequency in the range 0.15 to 0.5MHz.
Test Report No.: G0M-1206-2043-EU01-V01
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 23 of 32
Test setup
Test Report No.: G0M-1206-2043-EU01-V01
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 24 of 32
EMI voltage test in the dc-mains according to EN 301 489
Project number: G0M-1206-2043
Manufacturer:
EUT Name:
Model:
Test Site:
Operator:
Test Conditions:
LISN:
Mode:
Test Date:
Note:
Falcom Wireless Communication GmbH
Tracking Solution
FOX-EN
Eurofins Product Service GmbH
Mr. Handrik
Tnom: 23°C, Unom: 13,5 V DC
NNBM 8126D (+)
GSM 900 (GPRS 2 Slots)
13.07.2012
Index 15
80
EN 55022 AV Voltage Class B
RBW: 9 kHz, Line 1 Max Peak
EN 55022 QP Voltage Class B
RBW: 9 kHz, Line 1 Max Average
70
60
50
Voltage (dBµV)
40
30
20
10
0
-10
-20
-30
150 k
300 k
600 k
1000 k
2M
3M
5M
10 M
20 M
30 M
Frequency (Hz)
Test Report No.: G0M-1206-2043-EU01-V01
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 25 of 32
EMI voltage test in the dc-mains according to EN 301 489
Project number: G0M-1206-2043
Manufacturer:
EUT Name:
Model:
Test Site:
Operator:
Test Conditions:
LISN:
Mode:
Test Date:
Note:
Falcom Wireless Communication GmbH
Tracking Solution
FOX-EN
Eurofins Product Service GmbH
Mr. Handrik
Tnom: 23°C, Unom: 13,5 V DC
NNBM 8125 (-)
GSM 900 (GPRS 2 Slots)
13.07.2012
Index 16
80
EN 55022 AV Voltage Class B
RBW: 9 kHz, Neutral Max Peak
EN 55022 QP Voltage Class B
RBW: 9 kHz, Neutral Max Average
70
60
Voltage (dBµV)
50
40
30
20
10
0
-10
-20
150 k
300 k
600 k
1000 k
2M
3M
5M
10 M
20 M
30 M
Frequency (Hz)
Test Report No.: G0M-1206-2043-EU01-V01
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 26 of 32
3.3
Test Conditions and Results – Immunity to RF electromagnetic fields
Immunity to RF electromagnetic fields acc. to EN 301 489-7
Verdict: PASS
Laboratory Parameters:
Required prior to the test
During the test
Ambient Temperature
15 to 35°C
23°C
Relative Humidity
30 to 60%
45%
Test according to referenced
standards
Common Part
Reference Method
EN 301 489-1
EN 61000-4-3
Frequency range
Fully configured sample scanned
over the following frequency range
80MHz to 2.7GHz
Samples tested on the following
number of orientations
Number of orientations
EUT operating mode
1
4
Test parameters and results
Frequency [MHz]
Test level
[V/m]
Modulation
Frequency
step
Dwell time
Result
Criterion
80 – 1000
3
80% AM 1kHz
1%
2s
PASS
CT&CR
1400 – 2700
3
80% AM 1kHz
1%
2s
PASS
CT&CR
Comments:
Test Report No.: G0M-1206-2043-EU01-V01
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 27 of 32
Test setup
Test Report No.: G0M-1206-2043-EU01-V01
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 28 of 32
3.4
Test Conditions and Results – Immunity to conducted disturbances
Immunity to conducted disturbances acc. to EN 301 489-7
Verdict: PASS
Laboratory Parameters:
Required prior to the test
During the test
Ambient Temperature
15 to 35°C
23°C
Relative Humidity
30 to 60%
45%
Test according to referenced
standards
Common Part
Reference Method
EN 301 489-1
EN 61000-4-6
Frequency range
Fully configured sample scanned
over the following frequency range
0.15MHz to 80MHz
Points of Application
Application interface
Power
CDN
RS232
Clamp
GSM/GPS Antenna
Clamp
EUT operating mode
1
Test parameters and results
Frequency [MHz]
Test Port
Test level
[V]
Modulation
Frequency
step
Dwell time
Result
Criterion
0.15 - 80
Power
3
80% AM 1kHz
1%
2s
PASS
CT&CR
0.15 - 80
RS232
3
80% AM 1kHz
1%
2s
PASS
CT&CR
0.15 - 80
GSM/GPS
Antenna
3
80% AM 1kHz
1%
2s
PASS
CT&CR
Comments:
Test Report No.: G0M-1206-2043-EU01-V01
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 29 of 32
Test setup
Test Report No.: G0M-1206-2043-EU01-V01
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 30 of 32
3.5
Test Conditions and Results – Transients and surges in the vehicular environment
Transients and surges in the vehicular environment acc. to
EN 301 489-7
Verdict: PASS
Laboratory Parameters:
Required prior to the test
During the test
Ambient Temperature
15 to 35°C
23°C
Relative Humidity
30 to 60%
45%
Test according to referenced
standards
Common Part
Reference Method
EN 301 489-1
ISO 7637-2
EUT operating mode
1
Test parameters and results
Test Pulse
Test level
Duration
Result
Criterion
1*
III
10 pulse
PASS
TT&TR
2a*
III
10 pulse
PASS
TT&TR
2b*
III
10 pulse
PASS
TT&TR
3a
III
20 min
PASS
CT&CR
3b
III
20 min
PASS
CT&CR
4*
III
10 pulse
PASS
TT&TR
Comments:
* communication link need not to be maintained during the EMC exposure and may have to be re-established.
Test Report No.: G0M-1206-2043-EU01-V01
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 31 of 32
Test setup
Test Report No.: G0M-1206-2043-EU01-V01
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 32 of 32
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement