Evolve LFM-20 Datasheet


Add to my manuals
2 Pages

advertisement

Evolve LFM-20 Datasheet | Manualzz

2013

PRODUCT OVERVIEW

LFM-20

Product

Description

Specifications

Isolated Contact Fixture Module

The Evolve Isolated Contact Fixture Module is a component of the Evolve lighting control system and can handle loads of up to 277v. The device can be easily mounted in a single or multi-gang electrical box in any existing environment and is compatible with Z-Wave security systems.

Inclusion of this Module on a Z-Wave network allows remote ON/OFF control of the load connected and it’s fully scene capable.

This Isolated Contact Fixture Module is designed to work with other Evolve enabled devices.

Evolve nodes of other types can be included in the network and will also act as repeaters to increase the range of the network.

As part of a Z-Wave network, the LFM-20 will also act as a wireless repeater to ensure that commands intended for another device in the network are received. This is useful when the device would otherwise be out of the radio range of the wireless controller.

There are no field repairable assemblies on this unit. If service is needed, the unit must be returned where purchased.

SKU: LFM-20

Supported Networks:

- Z-Wave – Signal (Frequency) 908.42 MHz

• Range: Up to 100 feet line of sight between the Wireless Controller and/or the closest Evolve

Receiver Module

Power: 120 VAC, 50/60 Hz

Dimensions: 3” H x 1.875” W x 1.5” D

• Weight: 0.28 lbs.

2013

PRODUCT OVERVIEW

Wiring

The LFM-20 is wired as follows:

Black – represents the line input, 120VAC

• White – represents the neutral. The LFM-20 and the load must share the same neutral.

• Blue 1 (either blue wire) – 24V – 277V input for load switching

Blue 2 (either blue wire) – 24V – 277V output for load switching

The switch also has a green wire which serves as the ground. While there is a yellow wire present, it is not needed and should be cut and capped with either electrical tape or a wire nut.

Neutral

120VAC

Line

White

Black

Blue

Blue

24 to 277V

LOAD

20 Amps

Maximum

Status LED

Yellow

Push button to add node to network

Green Ground

In the case of a 3-way or 4-way circuit, traveler wires are not used when building an Evolve network. Instead, an LFM-20 may be used in conjunction with an LTM-5 to create a wireless,

“virtual” 3-way. See LTM-5 for further details.