Catalog FI01 2015 - Automation Technology - Siemens

Catalog FI01 2015 - Automation Technology - Siemens
4
© Siemens AG 2014
Level Measurement
4/2
Overview
4/9
Point level measurement
Capacitance switches
4/12
– Pointek CLS100
4/18
– Pointek CLS200 – Standard
4/27
– Pointek CLS200 – Digital
4/36
– Pointek CLS200 – Standard and Digital
4/44
– Pointek CLS300 – Standard
4/51
– Pointek CLS300 – Digital
4/57
– Pointek CLS300 – Standard and Digital
4/64
– Pointek CLS500
4/80
– Pointek CLS Specials
Vibrating switches
4/82
– SITRANS LVL100
4/88
– SITRANS LVL200
4/104
– SITRANS LVS100
4/107
– SITRANS LVS200
Continuous level measurement
(continued)
Accessories for ultrasonic
4/185
– EA aiming devices
4/187
– FMS mounting brackets
4/189
– TS-3 temperature sensor
4/191
Radar transmitters
4/194
– SITRANS Probe LR
4/198
– SITRANS LR200
4/207
– SITRANS LR200 Antennas
4/210
– SITRANS LR200 Specials
4/213
– SITRANS LR250 Horn Antenna
4/225
– SITRANS LR250 Specials
4/226
– SITRANS LR250 threaded PVDF antenna
4/232
– SITRANS LR250 threaded PVDF Specials
4/233
– SITRANS LR250 Flanged
Encapsulated Antenna
4/242
– SITRANS LR250 Flanged
Encapsulated Specials
4/243
– SITRANS LR250 Hygienic
Encapsulated Antenna
Rotation paddle switches
4/116
– SITRANS LPS200
Ultrasonic non-contacting switch
4/127
– Pointek ULS200
4/268
– SITRANS LR250 Hygienic
Encapsulated Specials
4/132
Continuous level measurement
Ultrasonic
4/269
– SITRANS LR260
4/274
– SITRANS LR460
4/279
– SITRANS LR260/LR460 Specials
4/280
– SITRANS LR560
4/285
– SITRANS LR560 Specials
4/286
Guided wave radar transmitters
4/289
– SITRANS LG series
Capacitance transmitters
4/322
– SITRANS LC300
4/336
– SITRANS LC500
4/359
– SITRANS LC300 and LC500 Specials
Ultrasonic transmitters
4/136
– SITRANS Probe LU
4/141
– The Probe
Ultrasonic controllers
4/144
– SITRANS LUT400 series
4/152
– MultiRanger 100/200
4/156
– HydroRanger 200
4/160
– SITRANS LU01 and LU02
4/164
– SITRANS LU10
4/168
– SITRANS LU AO
Ultrasonic transducers
4/171
– ST-H
4/360
Communication
SmartLinx module
4/174
– EchoMax XRS-5
4/361
Dolphin Plus Software
4/178
– EchoMax XPS
You can download all instructions,
catalogs and certificates for SITRANS L
free of charge: www.siemens.com/level
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Product Overview
■ Overview
Application
Device description
Page
Programming
Software
Point level measurement - Capacitance switches
Powerful range of level switches Pointek CLS100/CLS200/CLS300/CLS500
suitable for a variety of indus• CLS100: compact 2-wire inverse frequency shift capaci- 4/12
tries
tance switch for level detection in constricted spaces,
interfaces, solids, liquids, slurries, and foam
4
SIMATIC PDM
• CLS200: a versatile inverse frequency shift capacitance 4/18
level switch with optional rod/cable choices and configurable output, ideal for detection of liquids, solids,
slurries, foam, and interfaces; digital version
(with PROFIBUS PA) includes a display and provides
additional diagnostic features
SIMATIC PDM
• CLS300: inverse frequency shift capacitance level
4/44
switch with optional rod/cable choices and configurable
output. It is ideal for detecting liquids, solids, slurries,
foam and interfaces in demanding conditions where high
pressure and temperatures are present; digital version
(with PROFIBUS PA) includes a display and provides
additional diagnostic features
SIMATIC PDM
• CLS500: inverse frequency shift capacitance level
4/64
switch for detecting interfaces, solids, liquids, toxic and
aggressive chemicals in critical conditions of high temperature and pressure; HART communication for remote
commissioning
SIMATIC PDM
Point level measurement - Vibrating switches
Reliable vibrating point level
SITRANS LVL100/LVL200
switches for liquid and slurry
applications across all industries • LVL100: compact vibrating level switch for use in liquid
and slurry applications such as overflow, high, low,
and demand level applications. Also ideal for dry run
protection
Reliable vibrating point level
switches for bulk solids in a wide
variety of applications at a competitive price
4/82
-
• LVL200: advanced vibrating level switch for use in liquid 4/88
and slurry applications. Suited for most hazardous area
applications such as: overflow, high, low, demand,
and dry run protection; can also be used for Functional
Safety (SIL 2). Device suitable for use in accordance with
IEC 61508 and IEC 61511
-
SITRANS LVS100/LVS200
Vibrating point level switch designed to be impervious
to external vibrations and to provide reliable performance
in demanding bulk solids applications
• LVS100
4/104
-
• LVS200
4/107
-
Reliable rotating point level
SITRANS LPS200
4/116
switches for bulk solids in a wide • Rotating paddle switch for detection of high, low, and
variety of applications at a comdemand levels for a wide variety of bulk solids industries.
petitive price
Unique engineering provides long-lasting reliable performance
-
Point level measurement - Rotating paddle switch
4/2
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Product Overview
Application
Device description
Page
Programming
Software
4/127
-
4/136
-
Point level measurement - Ultrasonic non-contacting switch
Ultrasonic non-contacting switch Pointek ULS200
with two switch points for level
• Rugged design, no moving parts, and virtually maintedetection of bulk solids, liquids
nance-free
and slurries in a wide variety of
• Transducer available in ETFE or PVDF copolymer and
industries
therefore inert to most chemicals
Continuous measurement - Ultrasonic transmitters
2-wire loop powered ultrasonic
transmitter for level, volume, and
flow monitoring of liquids in
open channels, storage vessels
and simple process vessels
SITRANS Probe LU
• Continuous level measurement up to 12 m (40 ft) range
4
• Patented Sonic Intelligence signal processing
• Auto False-Echo Suppression
Compact level transmitter with
The Probe
integrated transducer for accu- • Simple, compact and competitively priced ultrasonic
rate level measurement for liquid level transmitter in several versions for maximum
applications
versatility:
- Three-wire system with alarm relay
- Two-wire system with current loop
4/141
SIMATIC PDM
4/144
SIMATIC PDM
Versatile short- to medium-range MultiRanger 100/200
4/152
ultrasonic single- and dual-ves- • Using non-contacting ultrasonic technology, the controlsel level controller for virtually
ler measures the level in short to medium range applicaany application in a wide range
tions up to 15 m (50 ft) of solids, liquids, or slurries
of industries
• Auto False-Echo Suppression of false echoes
SIMATIC PDM
Ultrasonic level controller for up HydroRanger 200
to six pumps - control, differen- • An economical, low-maintenance solution delivering
tial control, and open channel
control efficiency and productivity needed to meet
flow monitoring
today’s exacting standards
SIMATIC PDM
Continuous measurement - Ultrasonic controllers
The Siemens SITRANS LUT400
series controllers are compact,
single point, long-range ultrasonic controllers for continuous
level or volume measurement of
liquids, slurries, and solids, and
high accuracy monitoring of
open channel flow.
SITRANS LUT420/430/440
In addition to industry leading 1 mm (0.04 inch) accuracy,
each of the three models in the series are compatible with
our full range of EchoMax transducers and offer varying
degrees of pump, alarm, and other control functionality,
all from a very compact and easy-to-use interface.
• 1 mm accuracy
• HART communications
• Next Generation Sonic Intelligence
4/156
• Auto False-Echo Suppression of false echoes
Siemens FI 01 · 2015
4/3
© Siemens AG 2014
Level Measurement
Product Overview
Application
Device description
Page
Ultrasonic long-range level mon- SITRANS LU01/LU02
4/160
itoring system for liquids and
SITRANS LU10
4/164
solids
• Automatic conversion of level into volume for standard or
custom tank shapes
Programming
Software
Dolphin Plus
Dolphin Plus
• Easy to install and program
• Optional fieldbus card, e.g. PROFIBUS DP
Output module for
SITRANS LU10
4
4/168
-
4/171
-
• XRS-5: narrow beam angle of only 10°, measuring range 4/174
maximum 8 m (26 ft) for measurement of liquids, solids,
and slurries
-
Transducers for liquids and bulk EchoMax XPS
4/178
solids
• XPS series offers versions for various distances up to
XPS series: Hermetically sealed
30 m (100 ft) and up to a maximum temperature of 95 °C
PVDF enclosure for chemical
(203 °F)
immunity
-
SITRANS LU AO
• SITRANS LU AO analog output module provides remote
analog outputs for the measurement points of the
SITRANS LU10 transceiver
Continuous measurement - Ultrasonic transducers
ST-H/EchoMax XRS-5
ST-H: ETFE or PVDF transducer • ST-H: The narrow design of the ST-H allows the sensor
for chemicals
to be mounted using a 2 inch connection
XRS-5: Standard transducer for
applications to 8 m (26 ft)
Continuous measurement - Radar transmitters
2-wire, 6 GHz pulse radar level
transmitter for continuous monitoring of liquids and slurries in
storage vessels with nominal
pressure and temperature,
to a range of 20 m (66 ft)
4/4
Siemens FI 01 · 2015
SITRANS Probe LR
• Uni-Construction polypropylene rod antenna standard
• Process Intelligence signal processing
• Auto False-Echo Suppression of false echoes
4/194
SIMATIC PDM
© Siemens AG 2014
Level Measurement
Product Overview
Application
Device description
Page
Programming
Software
2-wire, 6 GHz pulse radar level
transmitter for continuous monitoring of liquids and slurries in
storage and process vessels
including high temperature and
pressure, to a range of 20 m
(66 ft)
SITRANS LR200
4/198
SIMATIC PDM
2-wire, 25 GHz pulse radar level
transmitter for continuous monitoring of liquids and slurries in
storage and process vessels
including high temperature and
pressure, to a range of 20 m
(66 ft); antenna designs ideal for
small vessels, low dielectric
media, food & beverages and
corrosive/aggressive media
SITRANS LR250
• Program without opening the lid, even in hazardous
areas, using patented infrared IS handheld programmer
AMS
SITRANS DTM
• Special Uni-Construction hermetically sealed polypropylene rod antenna has integrated threaded connection
• Built-in alphanumeric display with support in four languages
4/213
• Simple operation using the graphical local user interface
(LUI)
SIMATIC PDM
AMS
SITRANS DTM
• Plug-and-play setup using the intuitive Quick Start
Wizard
4
• 25 GHz high frequency allows for small horn antennas
and easy mounting in nozzles
• Process Intelligence signal processing for improved
measurement reliability and Auto False-Echo Suppression of fixed obstructions
2-wire, 25 GHz pulse radar level SITRANS LR260
4/269
transmitter for continuous moni- • Simple operation using the graphical local user interface
toring of solids and liquids up to
(LUI)
30 m (98.4 ft); ideal for measurement in extreme dust and high • Plug-and-play setup using the intuitive Quick Start
Wizard
temperatures
• 25 GHz high frequency allows for small horn antennas
and easy mounting in nozzles
SIMATIC PDM
• Process Intelligence signal processing for improved
measurement reliability and Auto False-Echo Suppression of fixed obstructions
4-wire, 24 GHz FMCW radar
level transmitter with extremely
high signal-to-noise ratio and
advanced signal processing for
continuous monitoring of solids
up to 100 m (328 ft); ideal for
measurement in extreme dust
SITRANS LR460
2-wire, 78 GHz FMCW radar
level transmitter for continuous
monitoring of solids in silos to a
range of 100 m (329 ft)
SITRANS LR560
4/274
SIMATIC PDM
4/280
SIMATIC PDM
• Process Intelligence for advanced signal processing and
quick and easy adjustment
• Self-guided Quick Start Wizard for plug and play start-up
• 100 m (328 ft) range for long-range and difficult applications
• Rugged stainless steel design
AMS
• 78 GHz high frequency provides very narrow beam,
virtually no mounting nozzle noise, and optimal reflection
from sloped solids
SITRANS DTM
• Aimer option to direct beam to area of interest, such as
draw point of cone
• Air purge connection is included for self-cleaning of
extremely sticky solids
• Lens antenna is highly resistant to product build-up
• Local display interface (LDI) allows local programming
and diagnostics
Siemens FI 01 · 2015
4/5
© Siemens AG 2014
Level Measurement
Product Overview
Application
Device description
Page
Programming
Software
SITRANS LG240/250/260/270
4/289
SIMATIC PDM
4/322
-
Continuous measurement - Guided wave radar transmitters
Guided wave radar transmitters
for short- and medium-range
level, level/interface,
and volume measurement
of liquids, slurries, and solids.
The four LG models are unaffected by changes in process
conditions, high temperatures
and pressures, and provide a
wide range of hygienic options.
• Measures accurately on materials with dielectric (dK) as
low as 1.4
• Guided wave radar measurement for up to 2 mm
(0.08 inch) accuracy
• Measures level, level/interface, and volume of solids,
slurries, and liquids
• 4 button programming for quick setup
• Reliable level measurement on harsh applications with
pressure up to 400 bar g (40 000 kPa) and temperatures
as high as 450 °C (842 °F)
4
Continuous level - Capacitance transmitters
For liquids and solids applications, ideal for standard industrial applications in chemical,
hydrocarbon processing, food
and beverage, and mining,
aggregate and cement industries
SITRANS LC300
• Sophisticated, but easy-to-adjust microprocessor combined with field-proven probes
• Patented active shield technology ensures measurements are unaffected by vapors, product deposits, dust,
and condensation
Level and interface transmitter SITRANS LC500
4/336
for extreme and critical process • Equipped with the HART Smart protocol for remote setup
conditions, such as oil and liquid and calibration
natural gas (LNG), toxic and
• Patented active shield technology ensures measureaggressive chemicals and
ments are unaffected by vapors, product deposits, dust,
vapours
and condensation
SIMATIC PDM
Communication
SmartLinx Module, Dolphin Plus software
• Optional communication modules, SmartLinx,
provide direct digital connection to popular
industrial fieldbus systems
• Dolphin Plus for quick and easy configuring,
monitoring, tuning, and diagnostics of
Siemens devices
4/6
Siemens FI 01 · 2015
4/360
-
4/361
-
© Siemens AG 2014
Level Measurement
Product Overview
Level Measurement Selector
Continuous Level
Conditions
Ultrasonic
Radar
Guided Wave
Radar
Capacitance
Gravimetric
Hydrostatic
pressure








Measurement
Level
Interface (liquid/liquid)
Interface (liquid/solid)

Volume






Mass






Changing density




Changing dielectric






Aggressive chemicals






Pressure/vacuum





High temperature








Flow (open channel)
Level Applications
Cryogenic





Steam





Hydrocarbon vapors/solvents





Turbulence

Foam






Build-up






High viscosity






Dust





Solids powders





Solids granules/pellets
< 25 mm (1 inch)





Solids > 25 mm (1 inch)


High angle of repose




4


 preferred
 condition dependent
Siemens FI 01 · 2015
4/7
© Siemens AG 2014
Level Measurement
Product Overview
Level Measurement Selector
Point Level
Conditions
Vibration
Capacitance
Paddle
Ultrasonic




Measurement
Level

Interface (liquid/liquid)


Changing density




Changing dielectric




Aggressive chemicals




Pressure/vacuum



High temperature



Interface (liquid/solid)
Volume
Mass
Flow (open channel)
Level Applications
4

Cryogenic
Turbulence


Steam


Hydrocarbon vapors/solvents


Foam


Build-up




High viscosity




Dust




Solids powders




Solids granules/pellets < 25 mm (1 inch)




Solids > 25 mm (1 inch)




High angle of repose




 preferred
 condition dependent
4/8
Siemens FI 01 · 2015



© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Capacitance
■ Overview
■ Mode of operation
Introduction
Common Terms
Inverse frequency shift capacitance point level and material
detection switches are designed to withstand the harsh environments of high pressure and high temperature applications.
Capacitance
Inverse Frequency Technology
Siemens inverse frequency shift capacitance devices incorporate a unique frequency-based approach to level measurement.
The capacitance units monitor the effect of capacitance based
on frequency change. The relationship between capacitance
and frequency is inverse. Because small level changes result in
a large frequency change, the result is excellent resolution and
accuracy.
Principle of Operation
Inverse frequency shift capacitance devices require two components: a reference electrode of a variable capacitor and the
measurement electrode. In capacitive level measurement,
the environment (typically the vessel wall) acts as the reference
electrode, while the probe supplies the measurement electrode.
The dielectric is composed of the vessel contents and, if the
measurement electrode is insulated, the insulating layer.
Operating principles
Dielectric = contents plus insulation
(non-conductive contents)
Dielectric = insulation
(conductive contents)
The property of a system of conductors and dielectrics that permits the storage of electricity when a potential difference exists
between the conductors. Its value is expressed as the ratio of a
quantity of electricity to a potential difference and the unit is a
Farad.
Capacitor
A device in a circuit that has the potential to store an electric
charge. Typically a capacitor has two conductors or electrodes
separated by a layer of a non-conducting material called a
dielectric. With the conductors on opposite sides of the dielectric layer oppositely charged by a source of voltage, the electrical energy of the charged system is stored in the polarized
dielectric.
Dielectric constant
The ability of a dielectric to store electrical potential energy
under the influence of an electric field. This is measured by a
ratio which compares the capacitance of a condenser with the
material as dielectric to its capacitance with a vacuum/dry air as
dielectric: the dielectric constant of air is 1.
Active shield
The portion of the probe isolated from the active measurement
section. The sensor signal is connected to the active shield portion of the probe, eliminating the electrical potential difference
between the shield and the measurement section. So, the shield
portion of the probe near the process connection is not affected
by changes in vapor concentration, material buildup, dust,
or condensation.
Probe
dia.
Internal
vessel wall
(Insulation)
Probe
sleeve
Internal vessel diameter
Inverse frequency shift capacitance operation
Capacitance is affected by the surface area of the electrodes,
the separation distance between the electrodes and the dielectric constant of the vessel contents. The dielectric constant is the
measure of a material’s ability to store energy. The relative
dielectric constant of air (vacuum) is 1; all other materials have
a higher value.
Siemens FI 01 · 2015
4/9
4
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Capacitance
■ Technical specifications
Point Level Measurement
4
Criteria
Pointek CLS100
Pointek CLS200
Pointek CLS300
Pointek CLS500
Typical applications
Liquids, slurries, powders,
granules, applications in
constricted spaces
Liquids, slurries, powders,
granules, foam, food, and
pharmaceuticals, petrochemicals
Liquids, slurries, powders,
granules, relatively high pressure and temperature, hazardous areas
Water in oil level, foam or
liquid/ foam level, glycol
regenerators, high-pressure
coalescers
Max. length
including sensor
100 mm (4 inch)
Rod: 5.5 m (18 ft)
Cable: up to 30 m (98 ft)
Rod: 1 m (40 inch)
Cable: 25 m (82 ft)
Rod: 1 m (40 inch)
Process temperature
(Temperature ratings are pressure dependent.
See Pressure/Temperature
curves for respective
product.)
Stainless steel process
connection:
• -30 ... +100 °C
(22 ...+212 °F)
• -40 ... +85 °C
(-40 ... +185 °F)
• With thermal
isolator:
-40 ... +125 °C
(-40 ... +257 °F)
• -40 ... +200 °C
(-40 ... +392 °F)
• HT version:
-40 ... +400 °C
(-40 ... +752 °F)
• -50 ... +200 °C
(-58 ... +392 °F)
• HT version:
-60 ... +400 °C
(-76 ... +752 °F)
Rod versions:
• Up to 25 bar g (365 psi g)
Up to 35 bar g
(511 psi g)
• Up to 150 bar g
(2 175 psi g)
Standard:
• 1 SPDT Form C relay,
solid-state switch
Standard:
• 1 SPDT Form C relay,
solid-state switch
• 4 ... 20/20 ... 4 mA 2-wire
current loop
• Solid-state switch
Digital:
• Solid-state switch included
Digital:
• Solid-state switch included
Standard:
• 3 LED indicators
Standard:
• 3 LED indicators
Digital:
• PROFIBUS PA;
SIMATIC PDM compatible
Digital:
• PROFIBUS PA;
SIMATIC PDM compatible
Standard:
• 12 ... 250 V AC/DC,
0 ... 60 Hz, 2 W max.
Standard:
• 12 ... 250 V AC/DC,
0 ... 60 Hz, 2 W max.
Digital:
• Bus voltage:
12 ... 30 V DC,
IS version
12 ... 24 V DC
• Current consumption:
12.5 mA
Digital:
• Bus voltage:
12 ... 30 V DC,
IS version
12 ... 24 V DC
• Current consumption:
12.5 mA
Fully Synthetic (PPS process
connection):
• -10 ... +100 °C
(14 ... 212 °F)
Up to 10 bar g
Process pressure
(Pressure ratings are tempera- (146 psi g)
ture dependent.
See Pressure/Temperature
curves for respective
product.)
Stainless steel cable or enclosure version:
• 4 ... 20/20 ... 4 mA
2-wire current loop
• Solid-state output
Output
Cable version:
• Up to 10 bar g (146 psi g)
Fully-synthetic version (PPS)
• Relay output
Communications
Power
Specifications
Standard:
• 12 ... 33 V DC
Intrinsically Safe
(Stainless steel version only):
• 10 ... 30 V DC
Approvals
Stainless steel cable or enclo- CSA, FM, CE, ATEX, RCM,
sure version:
Lloyds Register, WHG,
Vlarem II
CE, CSA, FM, ATEX, RCM,
Lloyds Register, WHG
Fully-synthetic version (PPS):
CSA, FM
4/10
Siemens FI 01 · 2015
CSA, FM, CE, ATEX, RCM,
Lloyds Register, WHG,
Vlarem II
HART, SIMATIC PDM
compatible
• 12 ... 33 V DC
• 3.6 ... 22 mA/
22 ... 3.6 mA
(2-wire current loop)
CE, CSA, FM, ATEX, RCM,
Lloyds Register, Bureau Veritas, Current Signaling according to NAMUR NE 43
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Capacitance
■ Application
Capacitance Application Questionnaire
Customer information
Contact:
Prepared By:
Company:
Date:
Address:
Notes on the Application:
City:
Country:
Zip/Postal Code:
Phone: (
E-mail:
Fax: (
Tank/Vessel Information
Type:
)
4
)
(Supply sketch where possible)
Sketch attached
Tank construction:
Storage
Metallic
Process
Dimensions:
Non-metallic
Agitated top, bottom or side
Separator
Height:
m/ft
Width/Diameter:
m/ft
Pressure:
FPSO
Normal:
(Floating Processing
Storage and Offloading) Maximum (relief):
Tank top:
Open
Tank bottom:
Sloped
Critical Information
Top Mount
Mounting:
Flat
Flat
Side Mount
Conical
Conical
Pipe Mount
Parabolic
Parabolic
Nozzle Length:
cm/inch
Nozzle Diameter:
cm/inch
Process Data
Liquid
Material being measured:
°C/°F Max:
Material temperature: Norm:
Measurement type:
Point level
Slurry
Solid
°C/°F
Constant dielectric:
No
Yes
DK Value
Continuous level
Interface level
Process pressure:
Coating build-up:
Installation
No
Upper material:
DK Value
Lower material:
DK Value
Min.
Max.
Yes
Conductive material:
Atmospheric steam:
No
No
Yes
Yes
DK Value
(indicate all that apply)
Power available:
Communications
Outputs required:
4 ... 20 mA
Relay
Solid state
HART / 4 ... 20 mA
PROFIBUS PA
Products recommended:
© Siemens Milltronics Process Instruments Inc.
www.siemens.com/processautomation
Form# 2-770R5
Capacitance Application Questionnaire
Siemens FI 01 · 2015
4/11
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS100
■ Overview
■ Configuration
Installation
20 (0.79) max.
Standpipes
≥ 50 (2)
4
Wall restriction
Pointek CLS100 is a compact 2-wire inverse frequency shift
capacitance switch for level and material detection in constricted spaces, interfaces, solids, liquids, slurries and foam,
with the ability to tune out build-up on probe.
■ Benefits
Easy installation with verification by built-in LED
Low maintenance with no moving parts
Sensitivity adjustment
Integrated cable or PBT enclosure versions available
Intrinsically Safe, Dust Ignition Proof, and General Purpose
options available
50 (2)
min.
50 (2)
•
•
•
•
•
■ Application
Pointek CLS100’s short insertion length of 100 mm (4 inch) and
versatility in various applications and in vessels or pipes makes
it a good replacement for traditional capacitance sensors.
Its advanced tip-sensing technology provides accurate, repeatable switchpoint performance. The PPS (Polyphenylene sulfide)
probe [optional PVDF (Polyvinylidene Fluoride)] is chemically
resistant with an effective process operating temperature
range from -30 to +100 °C (-22 to +212 °F) (7ML5501),
and -10 to +100 °C (14 to 212 °F) (7ML5610). The fully potted
design ensures reliability in a vibrating environment such as
agitated tanks up to 4 g. When used with a SensGuard protection cover, the CLS100 is protected from shearing, impact,
and abrasion in tough primary processes.
The Pointek CLS100 is available in three versions. The integral
cable version has a stainless steel process connection and
probe options of PPS or PVDF. The fully synthetic version has a
thermoplastic polyester enclosure with a PPS process connection combined with a PPS probe. The standard enclosure version
has a thermoplastic polyester enclosure with a stainless steel
process connection in combination with a PPS or PVDF probe.
• Key Applications: liquids, slurries, powders, granules,
food and pharmaceuticals, chemicals, hazardous areas
4/12
Siemens FI 01 · 2015
Pointek CLS100 installation, dimensions in mm (inch)
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS100
■ Technical specifications
Stainless steel
process connection
(integral cable or
enclosure version)
(7ML5501)
Fully synthetic
process connection
(enclosure version
only)
(7ML5610)
Mode of operation
Measuring principle
Inverse frequency shift
capacitive level
detection
Inverse frequency shift
capacitive level
detection
Change in picoFarad
(pF)
Change in picoFarad
(pF)
4 ... 20/20 ... 4 mA
2-wire loop
Solid-state:
30 V DC/30 V AC,
max. 82 mA
Min. or max.
4 ... 20/20 ... 4 mA
2-wire loop
Max. switching voltage:
60 V DC/30 V AC
Max. switching current:
1A
Min. or max.
2 mm (0.08 inch)
2 mm (0.08 inch)
Input
Measured variable
Output
Output signal
• Alarm output
1)
• Switch output
• Fail-safe mode
Accuracy
Repeatability
Rated operating
conditions2)
Installation conditions
• Location
Ambient conditions
• Ambient temperature
• Installation category
• Pollution degree
Medium conditions
• Relative dielectric
constant r
• Process temperature
• Pressure (vessel)
• Degree of protection
- Enclosure version
- Integral cable
version
• Cable inlet
Indoor/outdoor
Indoor/outdoor
-30 ... +85 °C
(-22 ... +185 °F)
I
4
-10 ... +85 °C
(14 ... 185 °F)
I
4
Min. 1.5
Min. 1.5
-30 ... +100 °C
(-22 ... +212 °F)
-1 ... +10 bar g
(-14.6 ... +146 psi g),
nominal2)
-10 ... +100 °C
(14 ... 212 °F)
-1 ... +10 bar g
(-14.6 ... +146 psi g),
nominal
IP68/Type 4/NEMA 4
IP65/Type 4/NEMA 4
IP68/Type 4/NEMA 4
Not applicable
½" NPT
(M20x1.5 optional)
½" NPT
(M20x1.5 optional)
Design
Enclosure/Integral cable Fully synthetic version
version
Stainless steel
process connection
(integral cable or
enclosure version)
(7ML5501)
Sensor length (nominal)
Process connection
material of probe/
wetted parts3)
100 mm (4 inch)
Connection: 316L
stainless steel;
Process seal: FKM
(optional FFKM);
Sensor: PPS
(optional PVDF)4)
Internal 5-point terminal
Connection
block,
(Enclosure version)
½" NPT wiring entrance,
M20x1.5 optional
4 conductors, 1 m
Connection
(Integral cable version) (3.3 ft), 0.5 mm²
(22 AWG), shielded,
polyester jacket
¾" NPT [(Taper),
Process connection
ANSI/ASME B1.20.1]
R 1" [(BSPT),
EN 10226/PT (JIS-T),
JIS B 0203]
G 1" [(BSPP),
EN ISO 228-1/PF (JIS-P),
JIS B 0202]
Power supply
• Standard
• Intrinsically Safe
Certificates and
approvals
Thermoplastic polyester Thermoplastic polyester
Transparent thermoplas- Transparent thermoplastic polycarbonate (PC) tic polycarbonate (PC)
316L stainless steel
Not applicable
100 mm (4 inch)
PPS process connection and PPS sensor
(Uni-Construction)
Removable internal
5-point terminal block,
½" NPT wiring entrance,
M20 x 1.5 optional
Not applicable
¾" NPT [(Taper),
ANSI/ASME B1.20.1]
R 1" [(BSPT),
EN 10226/PT (JIS-T),
JIS B 0203]
12 ... 33 V DC
Not applicable
• General: CE, CSA, FM, • General: CSA, FM
RCM
• Marine: Lloyds Register of Shipping, categories ENV1, ENV2,
and ENV5
Dust Ignition Proof
(barrier required):
CSA/FM Class II and
III, Div. 1, Groups E, F,
G T4
• Intrinsically Safe (barrier required): CSA/FM
Class I, II and III, Div. 1,
Groups A, B, C, D, E, F,
G T4
ATEX II 1 GD 1/2GD
EEx ia IIC T4 to T6
T107 °C
• Overfill protection:
WHG (Germany)
1)
When synthetic process connection version (7ML5610) is used in wet
locations, switching voltage of the relay is limited to 35 V DC/16 V AC.
2)
When operation is in areas classified as hazardous, observe restrictions
according to relevant certificate.
See also Pressure/Temperature curves on page 4/16.
3)
For Caustic Materials please contact [email protected]
http://www.siemens.com/automation/support-request for alternative
O Rings
4)
When FFKM O-ring (Option A22) is selected, process temperature is
restricted to -20 °C (-4 °F).
Material
• Body
(Enclosure version)
• Lid
(Enclosure version)
• Integrated cable body
(Integral cable
version)
12 ... 33 V DC
10 ... 30 V DC
(Intrinsically Safe
barrier required)
Fully synthetic
process connection
(enclosure version
only)
(7ML5610)
Siemens FI 01 · 2015
4/13
4
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS100
Selection and Ordering data
Article No.
Selection and Ordering data
Pointek CLS100, stainless steel process
connection
Compact 2-wire inverse frequency shift capacitance
switch for level and material detection in constricted
spaces, interfaces, solids, liquids, slurries and foam,
with the ability to tune out build-up on probe.
7ML5501-
Accessories
0 7777
SensGuard, ¾" NPT (PPS)
Only available for CLS100 with ¾" NPT thread
7ML1830-1DL
SensGuard, R 1" (BSPT) (PPS)
Only available for CLS100 with ¾" NPT thread
7ML1830-1DM
Tag, stainless steel, 12 x 45 mm (0.47 x 1.77 inch),
one text line, suitable for enclosures
7ML1930-1AC
Siemens Intrinsically Safe Barrier (DC powered),
ATEX II 1 G EEx ia
7NG4124-0AA00
½" NPT cable gland, nickel plated brass, fits cable
diameter 6 ... 12 mm (0.24 ... 0.47 inch)
-40 ... +100 °C (-40 ... +212 °F), IP68
(General Purpose)
7ML1830-1JA
M20 x 1.5 cable gland, PA polyamide,
ATEX II 2G EEx e II, fits cable diameter
7 ... 12 mm (0.28 ... 0.47 inch), -20 ... +70 °C
(-4 ... +158 °F), IP68 (General Purpose)
7ML1830-1JC
A
C
G
Selection and Ordering data
Article No.
7ML5610-
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Process connection
¾" NPT [(Taper), ANSI/ASME B1.20.1]
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
¢
¢
¢
A
E
J
Approvals
4
General Purpose: CE, CSA, FM, RCM
¢
CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, ¢
E, F, G T4; ATEX II 1 GD 1/2GD EEx ia IIC T4 to
T6 T107 °C 1)
CSA/FM Class II and III, Div. 1, Groups E, F, G1)
¢
Device version
Integral cable version (PPS probe)
Enclosure version (PPS probe), ½" NPT cable inlet
Integral cable version with PVDF probe body
Enclosure version with PVDF probe body
(½" NPT cable inlet)
Enclosure version (PPS probe), M20 x 1.5 cable
inlet
Enclosure version with PVDF probe body,
M20 x 1.5 cable inlet
Overfill protection
Not required
Required
1)
¢
¢
¢
¢
1
3
5
6
Pointek CLS100, PPS process connection
Compact 2-wire inverse frequency shift
capacitance switch for level and material detection
in constricted spaces, interfaces, solids, liquids,
slurries and foam, with the ability to tune out buildup on foam.
¢
7
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
¢
8
¢
¢
0
1
Barrier or Intrinsically Safe power supply required for Intrinsically Safe
protection
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Selection and Ordering data
Order code
Approvals
General Purpose: CSA, FM
Versions/Options
Enclosure version, PPS process connection,
½" NPT cable inlet
Enclosure version, PPS process connection,
M20 x 1.5
Overfill protection
Not required
Required
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
Acrylic coated, stainless steel tag [13 x 45 mm
(0.5 x 1.75 inch)]: Measuring-point number/
identification (max. 20 characters) specify
in plain text
¢ Y17
FFKM seal O-ring1)
¢ A22
Inspection Certificate Type 3.1 per EN 10204
¢ C12
Selection and Ordering data
0 7777
¢
A
¢
B
¢
D
¢
1
¢
2
¢
¢
0
1
Order code
Further designs
Operating Instructions
Article No.
Quick start manual, multi-language
Note: due to ATEX regulations one Quick start manual
is included with every product.
This device is shipped with the Siemens Milltronics
manual DVD containing ATEX Quick Starts and
Operating Instructions.
A5E32146158
1)
Process connection (PPS)
¾" NPT [(Taper), ANSI/ASME B1.20.1]
(PPS probe body)
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
(PPS probe body)
Article No.
See Temperature restriction on page 4/16
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Please add "-Z" to Article No. and specify Order
code(s).
Acrylic coated, stainless steel tag [13 x 45 mm
(0.5 x 1.75 inch)]: Measuring-point number/
identification (max. 20 characters) specify
in plain text
¢ Y17
FFKM seal O-ring1)
A22
Inspection Certificate Type 3.1 per EN 10204
C12
Operating Instructions
Article No.
Quick start manual, multi-language
Note: due to ATEX regulations one Quick start manual
is included with every product.
This device is shipped with the Siemens Milltronics
manual DVD containing ATEX Quick Starts and
Operating Instructions.
A5E32146158
Accessories
SensGuard, ¾" NPT (PPS)
Only available for CLS100 with ¾" NPT thread
SensGuard, R 1" (BSPT) (PPS)
Only available for CLS100 with ¾" NPT thread
Tag, stainless steel, 12 x 45 mm, (0.47 x 1.77 inch)
one text line, suitable for enclosures
1)
7ML1830-1DL
7ML1830-1DM
7ML1930-1AC
See Temperature restriction on page 4/16
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
4/14
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS100
■ Options
Process
connection
R 1" (BSPT)
70 (2.75)
32
(1.26)
91 (3.6)
Process
connection
¾" NPT
70 (2.75)
91 (3.6)
32
(1.26)
Optional SensGuard
Internal thread ¾" NPT
4
Optional SensGuard, dimensions in mm (inch)
Siemens FI 01 · 2015
4/15
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS100
■ Characteristic curves
Pressure/temperature curve
CLS100
Threaded process connections
(7ML5501)
Permitted operating pressures P
30 bar (435 psi)
20 bar (290 psi)
10 bar (145 psi)
atmospheric
4
-22 ºF 14 ºF
(-30 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
300 ºF
(149 ºC)
100 ºC
(212 ºF)
-29 ºC
(-20 ºF)
150 ºC
(302 ºF)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
Permitted operating temperature T
Example:
Permitted operating pressure = 10 bar (145 psi) at 75 °C
Pointek CLS100 Process Pressure/Temperature derating curves
■ Dimensional drawings
Enclosure version
36 (1.4) nominal*
1
2
Cable relief
5
Terminal block
ground lug
72.5 (2.9)
Output status
LED (red)
50
(2.0)
Sensitivity trimpot
Cable Ø 5 (0.2)
Trimpot cap
Output status
LED (red)
Sensor status
LED (yellow)
3
4
Sensor status
LED (yellow)
*Some G thread configurations deviate from this size.
Pointek CLS100, dimensions in mm (inch)
Siemens FI 01 · 2015
Process connection
98 (3.9)
nominal
98 (3.9)
nominal
120 (4.7)
Process connection
4/16
Cable inlet ½" NPT
(optional M20x1.5)
120 (4.7)
204 (8.0)
Ground post
Power LED (green)
80 (3.2)
Power LED (green)
Sensitivity trimpot
65 (2.6)
Integral cable version
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS100
■ Schematics
Integral Cable Version - Non Intrinsically Safe only
LOW/HIGH Alarm
White
White
Polarity as required
for
desired operation
Black
12 ... 33 V DC
Red
4/20 mA Loop Alarm
White
White
Black
Rmax = Vsupply - 10 V
20 mA
Red
V supply
12 ... 33 V DC
4
Solid State Switch Version
White
White
Solid state switch,
30 V DC/AC
(peak) 82 mA (max)
Black
Red
V supply
12 ... 33 V DC
Enclosure and Fully Synthetic Version
1
2
3
4
5
Terminal operations
Cable equivalent
mA current loop (+V or -V)
mA current loop (+V or -V)
ground
Solid state switch/relay*
Solid state switch/relay*
Red wire
Black wire
Cable shield
White wire
White wire
* Switch/relay normally open in unpowered state
* Relay not available on Pointek CLS100 IS version (7ML5501)
Note:
When driving an inductive load (for example, an external relay), a protection diode
must be connected in the correct polarity to prevent possible switch damage due to
inductive spikes generated by switching the inductor (please refer to instruction
manual). Intrinsically Safe Models - please follow local regulations and area
classifications; refer to instruction manual for more details.
Pointek CLS100 connections
Siemens FI 01 · 2015
4/17
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Standard
■ Overview
■ Configuration
Installation
4
Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level and material detection switch
with optional rod/cable choices and configurable output.
CLS200 is ideal for detection of liquids, solids, slurries, foam and
interfaces and has the ability to tune out build-up on the probe.
Keep unit out of path of falling material, or protect probe from
falling material.
■ Benefits
• Potted construction protects signal circuit from shock,
vibration, humidity and/or condensation
• High chemical resistance
• Level detection independent of tank or pipe earth reference
• Insensitive to product buildup due to high frequency oscillation
• 3 LED indicators for sensor status, output status, and power
Avoid areas where material build up occurs.
■ Application
Pointek CLS200 standard version has 3 LED indicators with
basic relay and solid-state switch alarms. Universal switch for
solids/liquids and interface.
.5
0
)
(2
Siemens FI 01 · 2015
in
4/18
M
The power supply is galvanically isolated and accepts a wide
range of voltages (12 to 250 V AC/DC). When used with thermal
isolator, the stainless steel and PPS (PVDF optional) materials
used in the probe construction provide a temperature rating up
to 125 °C (257 °F) on the process wetted portion of the probe.
The switch responds to any material with a dielectric constant of
1.5 or more by detecting a change in oscillating frequency,
and it can be set to detect before contact or on contact with the
probe. The CLS200 operates independently of the tank wall or
pipe so it does not require an external reference electrode for
level detection in a non-conductive vessel such as concrete or
plastic (EMC regulations applicable in some regions).
• Key Applications: liquids, slurries, powders, granules,
pressurized applications, hazardous areas
Install probe at least 50 (2) from tank wall.
Pointek CLS200 installation, dimensions in mm (inch)
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Standard
■ Technical specifications
Mode of operation
Measuring principle
Inverse frequency shift capacitive
level detection
Input
Measured variable
Change in picoFarad (pF)
Degree of protection
Cable inlet
Output
Output signal
• Relay output
- Max. contact voltage
- Max. switching capacity
1 SPDT Form C relay
• 30 V DC
• 250 V AC
• 5 A DC
• 8 A AC
150 W DC
- Time delay (ON and/or OFF)
2 000 VA AC
1 ... 60 s
- Max. contact current
Design
Material
• Enclosure
• Optional thermal isolator
Connection
• Solid-state output
Power supply
Certificates and approvals
General Purpose
Dust Ignition Proof
Flameproof Enclosure With IS Probe
Dust Ignition Proof with IS Probe
- Output
- Protection
- Max. switching voltage
Galvanically isolated
Against reversed polarity (bipolar)
• 30 V DC
• 30 V peak AC
- Max. load current
82 mA
- Voltage drop
< 1 V, typical at 50 mA
Explosion Proof Enclosure
With IS Probe
Marine
- Time delay (pre or post switching) 1 ... 60 s
Overfill Protection
Rated operating conditions1)
Installation conditions
• Location
Indoor/outdoor
Ambient conditions
• Ambient temperature
• Installation category
• Pollution degree
-40 ... +85 °C (-40 ... +185 °F)2)
II
4
Medium conditions
• Relative dielectric constant r
• Process temperature
- Without thermal isolator
- With thermal isolator
• Process pressure (rod version)
Others
Liquids, bulk solids, slurries and
interfaces
Min. 1.5
Epoxy-coated aluminum with gasket
316L stainless steel
Removable terminal block,
max. 2.5 mm²
IP65/Type 4/NEMA 4 (optional IP68)
2 x M20x1.5 thread
(option: 2 x ½" NPT conduit entry
including 1 plugged entry)
12 ... 250 V AC/DC, 0 ... 60 Hz
max. 2 W
CSA, FM, CE, RCM
ATEX II 1/2 D T100 °C
ATEX II 1 G EEx d[ia] IIC T6...T4
ATEX II 1/2 D T100 °C
CSA/FM Class II, Div. 1,
Groups E, F, G
CSA/FM Class III T4
CSA/FM Class I, Div. 1,
Groups A, B, C, D
CSA/FM Class II, Div. 1,
Groups E, F, G
CSA/FM Class III T4
Lloyds Register of Shipping,
Categories ENV1, ENV2 and ENV5
WHG (Germany)
VLAREM II
Pattern Approval (China)
1)
When operation is in areas classified as hazardous, observe restrictions
according to relevant certificate.
See also Pressure/Temperature curves on page 4/37.
2)
Thermal isolator is used if process connection temperature exceeds 85 °C
(185 °F)
3)
Pressure rating of process seal is temperature dependent.
See Pressure/Temperature curves on page 4/37.
-40 ... +85 °C (-40 ... +185 °F)2)
-40 ... +125 °C (-40 ... +257 °F)
-1 ... +25 bar g
(-14.6 ... +365 psi g) (nominal)
• Process pressure (cable version)3) -1 ... +10 bar g
(-14.6 ... +150 psi g) (nominal)
• Process pressure (sliding coupling -1 ... +10 bar g
(-14.6 ... +150 psi g) (nominal)
version)
Electromagnetic Compatibility
To comply with CE EMC regulations
(where applicable); the CLS200
should be installed per the instruction
manual.
Siemens FI 01 · 2015
4/19
4
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Standard
Design: Probe
Rod version
Sanitary version
Cable version
Sliding Coupling version
Max. length
5 500 mm (216.53 inch)
5 500 mm (216.53 inch)
30 000 mm (1 181.1 inch)
liquids and slurries
5 000 mm (196.85 inch)
solids (under loads)
5 500 mm (216.53 inch)
Process connection
R ¾", 1",
1½", 2" sanitary fitting clamp
1¼", 1½" [(BSPT),
EN 10226/PT (JIS-T),
JIS B 0203]
316L stainless steel
R ¾", 1", 1¼", 1½" [(BSPT),
EN 10226/PT (JIS-T),
JIS B 0203]
¾", 1", 1¼", 1½" NPT
[(Taper), ANSI/ASME B1.20.1]
G ¾", 1", 1½" [(BSPP),
EN ISO 228-1/PF (JIS-P),
JIS B 0202]
316L stainless steel
ASME/EN flange
R ¾", 1", 1¼", 1½" [(BSPT),
EN 10226/PT (JIS-T),
JIS B 0203]
¾", 1", 1¼", 1½" NPT
[(Taper), ANSI/ASME B1.20.1]
G ¾", 1",
¾", 1",
1¼", 1½" NPT
[(Taper), ANSI/ASME B1.20.1]
G ¾", 1",
1½" [(BSPP),
EN ISO 228-1/PF (JIS-P),
JIS B 0202]
1½" [(BSPP),
EN ISO 228-1/PF (JIS-P),
JIS B 0202]
4
316L stainless steel
ASME/EN flange
Extension material
316L stainless steel
optional PFA coated1)
316L stainless steel
Fluoroethylene propylene
(FEP) cable with stainless
steel core
316L stainless steel
Sensor wetted parts
PPS (optional PVDF)
PPS (optional PVDF)
PPS (optional PVDF)
PPS (optional PVDF)
O-ring seal material
FKM (optional FFKM)2)
FKM (optional FFKM)2)
FKM (optional FFKM)2)
FKM (optional FFKM)2)
Optional
Optional
Optional
Optional
User selected length
User selected length
Cable extension
User selected length
Thermal isolator
Extension
3)
1)
PFA coating (7ML5634 and 7ML5644) has 120 micron thickness.
2)
For Caustic Materials please contact [email protected] for alternative O-Rings
3)
Thermal isolator is used if process connection temperature exceeds 85 °C (185 °F).
4/20
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Standard
■ Selection and Ordering data
Pointek CLS200 - Standard - Rod Version with
Threaded or Flanged process connection
Versatile inverse frequency shift capacitance level
and material detection switch with optional rod/
cable choices and configurable output. CLS200 is
ideal for detection of liquids, solids, slurries, foam,
and interfaces, and has the ability to tune out buildup on the probe.
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Process connection
Threaded, 316L stainless steel
¾" NPT [(Taper), ANSI/ASME B1.20.1]
¢
1" NPT [(Taper), ANSI/ASME B1.20.1]
¢
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
¢
1½" NPT [(Taper), ANSI/ASME B1.20.1]
¢
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
¢
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
¢
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] ¢
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]¢
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] ¢
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P),
¢
JIS B 0202]
Welded flange, 316L stainless steel, raised face
1" ASME, 150 lb
¢
1" ASME, 300 lb
1" ASME, 600 lb
1½" ASME, 150 lb
¢
1½" ASME, 300 lb
1½" ASME, 600 lb
2" ASME, 150 lb
¢
2" ASME, 300 lb
2" ASME, 600 lb
3" ASME, 150 lb
¢
3" ASME, 300 lb
3" ASME, 600 lb
4" ASME, 150 lb
¢
4" ASME, 300 lb
4" ASME, 600 lb
Welded flange, 316L stainless steel,
Type A flat faced
DN 25, PN 16
¢
DN 25, PN 40
DN 40, PN 16
¢
DN 40, PN 40
DN 50, PN 16
¢
DN 50, PN 40
DN 80, PN 16
¢
DN 80, PN 40
DN 100, PN 16
¢
DN 100, PN 40
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5 or EN 1092-1 standard.)
Probe length (length from flange face)
(threaded lengths include process thread)
Note: No Y01 needed in Order code for
standard lengths
Compact [threaded 120 mm (4.72 inch),
¢
Flanged 98 mm (3.86 inch)]
Extended rod, 250 mm (9.84 inch)
¢
Extended rod, 350 mm (13.78 inch)
¢
Extended rod, 500 mm (19.69 inch)
¢
Extended rod, 750 mm (29.53 inch)
¢
Extended rod, 1 000 mm (39.37 inch)
¢
Extended rod, 1 250 mm (49.21 inch)
¢
Extended rod, 1 350 mm (53.15 inch)
¢
Extended rod, 1 500 mm (59.06 inch)
¢
Extended rod, 1 750 mm (68.90 inch)
¢
Extended rod, 2 000 mm (78.74 inch)
¢
Article No.
7ML563077 7 77 - 77 7 0
0A
0B
0C
0D
1A
1B
1D
3A
3B
3D
5A
5B
5C
5D
5E
5F
5G
5H
5J
5K
5L
5M
5N
5P
5Q
6A
6B
6C
6D
6E
6F
6G
6H
6J
6K
A
B
C
D
E
F
G
H
J
K
L
■ Selection and Ordering data
Article No.
Pointek CLS200 - Standard - Rod Version with
7ML5630Threaded or Flanged process connection
7 7 7 77 - 77 7 0
Versatile inverse frequency shift capacitance level
and material detection switch with optional rod/
cable choices and configurable output. CLS200 is
ideal for detection of liquids, solids, slurries, foam,
and interfaces, and has the ability to tune out buildup on the probe.
Add Order code Y01 and plain text:
"Insertion length ... mm"
Extended rod, 210 ... 1 000 mm (8.27 ... 39.37 inch) ¢
M
Extended rod, 1 001 ... 2 000 mm
¢
N
(39.41 ... 78.74 inch)
Extended rod, 2 001 ... 3 000 mm
¢
P
(78.78 ... 118.11 inch)
Extended rod, 3 001 ... 4 000 mm
¢
Q
(118.15 ... 157.48 inch)
Extended rod, 4 001 ... 5 000 mm
¢
R
(157.52 ... 196.85 inch)
Extended rod, 5 001 ... 5 500 mm
¢
S
(196.89 ... 216.53 inch)
Thermal isolator
Without thermal isolator
¢
0
With thermal isolator [for process connection
¢
1
temperatures over 85 °C (185 °F)]
Remote mount electronics and
mounting bracket
With 2 m (79 inch) of cable1)
¢
2
With 5 m (197 inch) of cable1)
¢
3
Wetted seals
FKM
¢
0
FFKM [for process temperatures above -20 °C (-4 °F)]¢
1
Probe material
316L stainless steel with PPS probe body
¢
0
316L stainless steel with PVDF probe body
¢
1
Approvals
Dust Ignition Proof:
¢
C
CE, RCM, ATEX II 1/2 D T100 °C
Flameproof Enclosure with IS Probe:
¢
D
CE, RCM, ATEX II 1 G EEx d[ia] IIC T6 ... T4,
ATEX II 1/2 D T100 °C
Flameproof Enclosure with IS Probe,
¢
E
with WHG approval:
CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6 ... T4,
ATEX II 1/2 D T100 °C
Dust Ignition Proof with IS Probe:
¢
F
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
Explosion Proof Enclosure with IS Probe:
¢
G
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
General Purpose (CSA, FM)
¢
H
General Purpose (CE, RCM)
¢
J
General Purpose (CSA, FM, CE, RCM)
¢
K
with WHG approval
Enclosure and lid
Aluminum epoxy coated
2 x ½" NPT via adapter - cable inlet, IP65
¢
A
2 x M20 x 1.5 cable inlet IP65
¢
B
2 x ½" NPT via adapter - cable inlet, IP68
¢
C
2 x M20 x 1.5 cable inlet IP68
¢
D
1)
Available with Approvals options F ... H
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Siemens FI 01 · 2015
4/21
4
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Standard
Selection and Ordering data
Order code
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
Total insertion length: enter the total insertion length ¢ Y01
in plain text description
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Measuring-point number/identification
(max. 27 characters) specify in plain text
Manufacturer's test certificate: M to DIN 55350,
Part 18 and ISO 9000
¢ C11
Inspection Certificate Type 3.1 per EN 10204
¢ C12
Operating Instructions
4
Note: The Operating Instructions should be
ordered as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
manual library.
See page 4/36
Accessories
See page 4/36
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Selection and Ordering data
Pointek CLS200 - Standard - Cable Version with
Threaded or Flanged process connection
Versatile inverse frequency shift capacitance level
and material detection switch with optional rod/
cable choices and configurable output. CLS200 is
ideal for detection of liquids, solids, slurries, foam,
and interfaces, and has the ability to tune out buildup on the probe.
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Process connection
Threaded, 316L stainless steel
¾" NPT [(Taper), ANSI/ASME B1.20.1]
¢
1" NPT [(Taper), ANSI/ASME B1.20.1]
¢
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
¢
1½" NPT [(Taper), ANSI/ASME B1.20.1]
¢
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
¢
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
¢
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] ¢
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]¢
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] ¢
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P),
¢
JIS B 0202]
Welded flange, 316L stainless steel, raised face
1" ASME, 150 lb
1" ASME, 300 lb
1" ASME, 600 lb
1½" ASME, 150 lb
1½" ASME, 300 lb
1½" ASME, 600 lb
2" ASME, 150 lb
2" ASME, 300 lb
2" ASME, 600 lb
3" ASME, 150 lb
3" ASME, 300 lb
3" ASME, 600 lb
4" ASME, 150 lb
4" ASME, 300 lb
4" ASME, 600 lb
Welded flange, 316L stainless steel,
Type A flat faced
DN 25, PN 16
DN 25, PN 40
DN 40, PN 16
DN 40, PN 40
DN 50, PN 16
DN 50, PN 40
DN 80, PN 16
DN 80, PN 40
DN 100, PN 16
DN 100, PN 40
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5 or EN 1092-1 standard.)
Probe length (length from flange face)
(threaded lengths include process thread)
Note: No Y01 needed in Order code for
standard lengths
Extended cable, 3 000 mm (118.11 inch), length
can be determined by customer on assembly1)
Extended cable, 6 000 mm (236.22 inch), length
can be determined by customer on assembly1)
Add Order code Y01 and plain text:
"Insertion length ... mm"
Extended cable, 500 ... 5 000 mm
(19.69 ... 196.85 inch)
Extended cable, 5 001 ... 10 000 mm
(196.89 ... 393.70 inch)
Extended cable, 10 001 ... 15 000 mm
(393.74 ... 590.55 inch)
Extended cable, 15 001 ... 20 000 mm
(590.59 ... 787.4 inch)
Extended cable, 20 001 ... 25 000 mm
(787.44 ... 984.25 inch)
Extended cable, 25 001 ... 30 000 mm
(984.29 ... 1 181.1 inch)
4/22
Siemens FI 01 · 2015
Article No.
7ML56317 7 7 77 - 77 7 0
0A
0B
0C
0D
1A
1B
1D
3A
3B
3D
¢ 5A
5B
5C
¢ 5D
5E
5F
¢ 5G
5H
5J
¢ 5K
5L
5M
¢ 5N
5P
5Q
¢ 6A
6B
¢ 6C
6D
¢ 6E
6F
¢ 6G
6H
¢ 6J
6K
¢
A
¢
B
¢
C
¢
D
¢
E
¢
F
¢
G
¢
H
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Standard
Selection and Ordering data
Article No.
Pointek CLS200 - Standard - Cable Version with
7ML5631Threaded or Flanged process connection
77 7 77 - 77 7 0
Versatile inverse frequency shift capacitance level
and material detection switch with optional rod/
cable choices and configurable output. CLS200 is
ideal for detection of liquids, solids, slurries, foam,
and interfaces, and has the ability to tune out buildup on the probe.
Thermal isolator
Without thermal isolator
¢
0
With thermal isolator [for process connection
¢
1
temperatures over 85 °C (185 °F)]
Remote mount electronics and mounting
bracket
With 2 m (79 inch) of cable2)
2
¢
With 5 m (197 inch) of cable2)
¢
3
Wetted seals
FKM and PTFE
¢
0
FFKM and PTFE [for process temperatures above ¢
1
-20 °C (-4 °F)]
Probe material
FEP jacketed cable with PPS probe body
0
¢
FEP jacketed cable with PVDF probe body
¢
1
Approvals
Dust Ignition Proof:
CE, RCM, ATEX II 1/2 D T100 °C
Flameproof Enclosure with IS Probe:
CE, RCM, ATEX II 1 G EEx d[ia] IIC T6...T4,
ATEX II 1/2 D T100 °C
Flameproof Enclosure with IS Probe,
with WHG approval:
CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T4,
ATEX II 1/2 D T100 °C
Dust Ignition Proof with IS Probe:
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
Explosion Proof Enclosure with IS Probe:
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
General Purpose (CSA, FM)
General Purpose (CE, RCM)
General Purpose (CSA, FM, CE, RCM)
with WHG approval
Enclosure and lid
Aluminum epoxy coated
2 x ½" NPT via adapter - cable inlet, IP65
2 x M20 x1.5 cable inlet, IP65
2 x ½" NPT via adapter - cable inlet, IP68
2 x M20 x1.5 cable inlet, IP68
¢
C
¢
D
¢
E
¢
F
¢
G
¢
¢
¢
H
J
K
¢
¢
¢
¢
1)
Sensor detached to allow customer to set desired cable length
2)
Available with Approvals options F ... H
Order code
Selection and Ordering data
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
Total insertion length: enter the total insertion length ¢ Y01
in plain text description
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Measuring-point number/identification
(max. 27 characters) specify in plain text
Manufacturer's test certificate: M to DIN 55350,
Part 18 and ISO 9000
¢ C11
Inspection Certificate Type 3.1 per EN 10204
¢ C12
Operating Instructions
Note: The Operating Instructions should be
ordered as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
manual library.
See page 4/36
Accessories
See page 4/36
4
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
A
B
C
D
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Siemens FI 01 · 2015
4/23
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Standard
Selection and Ordering data
Article No.
Selection and Ordering data
Article No.
Pointek CLS200 - Standard - Rod with
Sanitary process connection
Versatile inverse frequency shift capacitance level
and material detection switch with optional rod/
cable choices and configurable output. CLS200 is
ideal for detection of liquids, solids, slurries, foam,
and interfaces, and has the ability to tune out buildup on the probe.
7ML5632-
Pointek CLS200 - Standard - Rod with
Sanitary process connection
Versatile inverse frequency shift capacitance level
and material detection switch with optional rod/
cable choices and configurable output. CLS200 is
ideal for detection of liquids, solids, slurries, foam,
and interfaces, and has the ability to tune out buildup on the probe.
7ML5632-
77777 - 777 0
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Approvals
Process connection
Sanitary 316L stainless steel
1" sanitary fitting clamp
1½" sanitary fitting clamp
2" sanitary fitting clamp
4
¢ 8A
8B
8C
2½" sanitary fitting clamp
¢ 8D
3" sanitary fitting clamp
8E
(Note: Sanitary connection dimensionally
corresponds to the applicable ISO 2852 standard)
Probe length (length from process connection
face)
Note: No Y01 needed in Order code for
standard lengths
Compact 98 mm (3.86 inch)
Extended rod, 250 mm (9.84 inch)
Extended rod, 350 mm (13.78 inch)
¢
¢
¢
A
B
C
Extended rod, 500 mm (19.69 inch)
Extended rod, 750 mm (29.53 inch)
Extended rod, 1 000 mm (39.37 inch)
¢
¢
¢
D
E
F
Extended rod, 1 250 mm (49.21 inch)
Extended rod, 1 350 mm (53.15 inch)
Extended rod, 1 500 mm (59.06 inch)
¢
¢
¢
G
H
J
Extended rod, 1 750 mm (68.90 inch)
Extended rod, 2 000 mm (78.74 inch)
¢
¢
K
L
Add Order code Y01 and plain text:
"Insertion length ... mm"
Extended rod, 110 ... 350 mm (4.3 ... 13.78 inch) ¢
Extended rod, 351 ... 1 000 mm (13.78 ... 39.37 inch) ¢
Extended rod, 1 001 ... 2 000 mm
¢
(39.41 ... 78.74 inch)
Extended rod, 2 001 ... 3 000 mm
(78.78 ... 118.11 inch)
Extended rod, 3 001 ... 4 000 mm
(118.15 ... 157.48 inch)
Extended rod, 4 001 ... 5 000 mm
(157.52 ... 196.85 inch)
Extended rod, 5 001 ... 5 500 mm
(196.89 ... 216.53 inch)
Thermal isolator
Without thermal isolator
With thermal isolator [for process connection
temperatures over 85 °C (185 °F)]
Remote mount electronics and
mounting bracket
Remote mount electronics with 2 m (79 inch)
of cable1)
Remote mount electronics with 5 m (197 inch)
of cable1)
Wetted seals
FKM
FFKM
[for process temperatures above -20 °C (-4 °F)]
Probe material
316L stainless steel with PPS probe body
316L stainless steel with PVDF probe body
4/24
Siemens FI 01 · 2015
77777 - 777 0
Dust Ignition Proof:
CE, RCM, ATEX II 1/2 D T100 °C
¢
C
Flameproof Enclosure with IS Probe:
CE, RCM, ATEX II 1 G EEx d[ia] IIC T6 ... T4,
ATEX II 1/2 D T100 °C
¢
D
Flameproof Enclosure with IS Probe,
with WHG approval:
CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6 ... T4,
ATEX II 1/2 D T100 °C
¢
E
Dust Ignition Proof with IS Probe:
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
¢
F
Explosion Proof Enclosure with IS Probe:
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
¢
G
General Purpose (CSA, FM)
¢
H
General Purpose (CE, RCM)
¢
J
General Purpose (CSA, FM, CE, RCM)
with WHG approval
¢
K
Enclosure and lid
Aluminum epoxy coated
2 x ½" NPT via adapter - cable inlet, IP65
2 x M20x1.5 cable inlet, IP65
2 x ½" NPT via adapter - cable inlet, IP68
2 x M20x1.5 cable inlet, IP68
1)
¢
¢
¢
¢
A
B
C
D
Available with Approvals options F ... H
M
N
P
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
¢
Q
Selection and Ordering data
¢
R
Further designs
¢
S
Please add "-Z" to Article No. and specify Order
code(s).
¢
T
Total insertion length: enter the total insertion length ¢ Y01
in plain text description
¢
¢
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Measuring-point number/identification
(max. 27 characters) specify in plain text
0
1
¢
2
¢
3
Order code
Manufacturer's test certificate: M to DIN 55350,
Part 18 and ISO 9000
¢ C11
Inspection Certificate Type 3.1 per EN 10204
¢ C12
Operating Instructions
¢
¢
¢
¢
0
1
0
1
Note: The Operating Instructions should be
ordered as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
manual library.
See page 4/36
Accessories
See page 4/36
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Standard
Selection and Ordering data
Article No.
Selection and Ordering data
Pointek CLS200 - Standard - Sliding Coupling
with Threaded process connection
Versatile inverse frequency shift capacitance level
and material detection switch with optional rod/
cable choices and configurable output. CLS200 is
ideal for detection of liquids, solids, slurries, foam,
and interfaces, and has the ability to tune out buildup on the probe.
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Process connection
Threaded, 316L stainless steel
¾" NPT [(Taper), ANSI/ASME B1.20.1]
¢
1" NPT [(Taper), ANSI/ASME B1.20.1]
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
1½" NPT [(Taper), ANSI/ASME B1.20.1]
¢
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
7ML563377 7 77 - 77 7 0
Pointek CLS200 - Standard - Sliding Coupling
7ML5633with Threaded process connection
7 7 7 77 - 77 7 0
Versatile inverse frequency shift capacitance level
and material detection switch with optional rod/
cable choices and configurable output. CLS200 is
ideal for detection of liquids, solids, slurries, foam,
and interfaces, and has the ability to tune out buildup on the probe.
Approvals
Dust Ignition Proof:
¢
C
CE, RCM, ATEX II 1/2 D T100 °C
Flameproof Enclosure with IS Probe:
¢
D
CE, RCM, ATEX II 1 G EEx d[ia] IIC T6...T4,
ATEX II 1/2 D T100 °C
Flameproof Enclosure with IS Probe,
¢
E
with WHG approval:
CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T4,
ATEX II 1/2 D T100 °C
Dust Ignition Proof with IS Probe:
¢
F
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
Explosion Proof Enclosure with IS Probe:
¢
G
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
General Purpose (CSA, FM)
¢
H
General Purpose (CE, RCM)
¢
J
General Purpose (CSA, FM, CE, RCM)
¢
K
with WHG approval
Enclosure and lid
Aluminum epoxy coated
2 x ½" NPT via adapter - cable inlet, IP65
¢
A
2 x M20x1.5 cable inlet, IP65
¢
B
2 x ½" NPT via adapter - cable inlet, IP68
¢
C
2 x M20x1.5 cable inlet, IP68
D
¢
Probe length (length from flange face)
(threaded lengths include process thread)
Note: No Y01 needed in Order code for
standard lengths
Extended rod, 350 mm (13.78 inch)
Extended rod, 500 mm (19.69 inch)
Extended rod, 750 mm (29.53 inch)
Extended rod, 1 000 mm (39.37 inch)
Extended rod, 1 250 mm (49.21 inch)
Extended rod, 1 350 mm (53.15 inch)
Extended rod, 1 500 mm (59.06 inch)
Extended rod, 1 750 mm (68.90 inch)
Extended rod, 2 000 mm (78.74 inch)
Add Order code Y01 and plain text:
"Insertion length ... mm"
Extended rod, 350 ... 1 000 mm
(13.78 ... 39.37 inch)
Extended rod, 1 001 ... 2 000 mm
(39.41 ... 78.74 inch)
Extended rod, 2 001 ... 3 000 mm
(78.78 ... 118.11 inch)
Extended rod, 3 001 ... 4 000 mm
(118.15 ... 157.48 inch)
Extended rod, 4 001 ... 5 000 mm
(157.52 ... 196.85 inch)
Extended rod, 5 001 ... 5 500 mm
(196.89 ... 216.53 inch)
Thermal isolator
Without thermal isolator
With thermal isolator [for process connection
temperatures over 85 °C (185 °F)]
Remote mount electronics and
mounting bracket
With 2 m (79 inch) of cable1)
With 5 m (197 inch) of cable1)
Wetted seals
FKM and PTFE
FFKM and PTFE [for process temperatures above
-20 °C (-4 °F)]
Probe material
316L stainless steel with PPS probe body
316L stainless steel with PVDF probe body
¢
¢
¢
¢
¢
¢
¢
¢
¢
0A
0B
0C
0D
1A
1B
1D
3A
3B
3D
C
D
E
F
G
H
J
K
L
1)
¢
M
¢
N
¢
P
Article No.
Available with Approvals options F ... H
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Order code
Selection and Ordering data
Further designs
¢
Q
¢
R
Please add "-Z" to Article No. and specify Order
code(s).
¢
S
Total insertion length: enter the total insertion length ¢ Y01
in plain text description
¢
¢
¢
¢
¢
¢
¢
¢
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Measuring-point number/identification
(max. 27 characters) specify in plain text
0
1
2
3
Manufacturer's test certificate: M to DIN 55350,
Part 18 and ISO 9000
¢ C11
Inspection Certificate Type 3.1 per EN 10204
¢ C12
Operating Instructions
0
1
0
1
Note: The Operating Instructions should be
ordered as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
manual library.
See page 4/36
Accessories
See page 4/36
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Siemens FI 01 · 2015
4/25
4
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Standard
4
Selection and Ordering data
Article No.
Selection and Ordering data
Article No.
Pointek CLS200 - Standard - PFA Coated Rod
with PFA Coated Flanged process connection
Versatile inverse frequency shift capacitance level
and material detection switch with optional rod/
cable choices and configurable output. CLS200 is
ideal for detection of liquids, solids, slurries, foam,
and interfaces, and has the ability to tune out buildup on the probe.
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Process connection
Welded flange, 316L stainless steel, raised face
1" ASME, 150 lb
1" ASME, 300 lb
1" ASME, 600 lb
1½" ASME, 150 lb
1½" ASME, 300 lb
1½" ASME, 600 lb
2" ASME, 150 lb
2" ASME, 300 lb
2" ASME, 600 lb
3" ASME, 150 lb
3" ASME, 300 lb
3" ASME, 600 lb
4" ASME, 150 lb
4" ASME, 300 lb
4" ASME, 600 lb
Welded flange, 316L stainless steel,
Type A flat faced
DN 25, PN 16
DN 25, PN 40
DN 40, PN 16
DN 40, PN 40
DN 50, PN 16
DN 50, PN 40
DN 80, PN 16
DN 80, PN 40
DN 100, PN 16
DN 100, PN 40
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5 or EN 1092-1 standard.)
Probe length (length from flange face)
(threaded lengths include process thread)
Note: No Y01 needed in Order code for
standard lengths
Compact 98 mm (3.86 inch)
Extended rod, 250 mm (9.84 inch)
Extended rod, 350 mm (13.78 inch)
7ML563477 7 77 - 77 7 0
Pointek CLS200 - Standard - PFA Coated Rod
with PFA Coated Flanged process connection
Versatile inverse frequency shift capacitance level
and material detection switch with optional rod/
cable choices and configurable output. CLS200 is
ideal for detection of liquids, solids, slurries, foam,
and interfaces, and has the ability to tune out buildup on the probe.
Thermal isolator
Without thermal isolator
With thermal isolator [for process connection
temperatures over 85 °C (185 °F)]
Remote mount electronics and
mounting bracket
With 2 m (79 inch) of cable
With 5 m (197 inch) of cable
7ML56347 7 7 77 - 77 7 0
5A
5B
5C
5D
5E
5F
5G
5H
5J
5K
5L
5M
5N
5P
5Q
6A
6B
6C
6D
6E
6F
6G
6H
6J
6K
Selection and Ordering data
0
1
0
1
F
G
H
A
B
C
D
Order code
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
A
B
C
D
E
F
G
H
Extended rod, 1 500 mm (59.06 inch)
Extended rod, 1 750 mm (68.90 inch)
Extended rod, 2 000 mm (78.74 inch)
Add Order code Y01 and plain text:
"Insertion length ... mm"
Extended rod, 200 ... 1 000 mm (7.87 ... 39.37 inch)
Extended rod, 1 001 ... 2 000 mm
(39.41 ... 78.74 inch)
Extended rod, 2 001 ... 3 000 mm
(78.78 ... 118.11 inch)
Extended rod, 3 001 ... 4 000 mm
(118.15 ... 157.48 inch)
Extended rod, 4 001 ... 5 000 mm
(157.52 ... 196.85 inch)
Extended rod, 5 001 ... 5 500 mm
(196.89 ... 216.53 inch)
J
K
L
Siemens FI 01 · 2015
2
3
Wetted seals
FKM
FFKM [for process temperatures above
-20 °C (-4 °F)]
Probe material
PFA Coated 316L stainless steel with
PPS probe body
PFA Coated 316L stainless steel with
PVDF probe body
Approvals
Dust Ignition Proof with IS Probe:
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
Explosion Proof Enclosure with IS Probe:
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
General Purpose (CSA, FM)
Enclosure and lid
Aluminum epoxy coated
2 x ½" NPT via adapter - cable inlet, IP65
2 x M20x1.5 cable inlet, IP65
2 x ½" NPT via adapter - cable inlet, IP68
2 x M20x1.5 cable inlet, IP68
Extended rod, 500 mm (19.69 inch)
Extended rod, 750 mm (29.53 inch)
Extended rod, 1 000 mm (39.37 inch)
Extended rod, 1 250 mm (49.21 inch)
Extended rod, 1 350 mm (53.15 inch)
4/26
0
1
Total insertion length: enter the total insertion length
in plain text description
Y01
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 27 characters) specify in plain text
Y15
Manufacturer's test certificate: M to DIN 55350,
Part 18 and ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Operating Instructions
See page 4/36
M
N
Note: The Operating Instructions should be
ordered as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
manual library.
P
Accessories
See page 4/36
Q
R
S
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Digital
■ Overview
■ Configuration
Installation
4
Pointek CLS200 (digital version) is a versatile inverse frequency
shift capacitance level and material detection switch with
optional rod/cable choices and configurable output. CLS200 is
ideal for detection of liquids, solids, slurries, foam and interfaces
and has the ability to tune out build-up on the probe. The digital
version includes PROFIBUS PA, an LCD display, and advanced
diagnostic features.
Keep unit out of path of falling material, or protect probe from
falling material.
■ Benefits
• Potted construction protects signal circuit from shock,
vibration, humidity and/or condensation
• High chemical resistance
• Level detection independent of tank or pipe earth reference
• Insensitive to product buildup due to high frequency oscillation
• High sensitivity allows installation in a wide range of liquids,
solids or slurry applications
• Integral LCD display allows for easy menu-driven setup
• PROFIBUS PA communication (SIMATIC PDM compatible)
Avoid areas where material build up occurs.
M
■ Application
in
.5
)
(2
The power supply is galvanically isolated and accepts a wide
range of voltages (12 to 30 V DC). When used with thermal
isolator, the stainless steel and PPS (PVDF optional) materials
used in the probe construction provide a temperature rating
up to 125 °C (257 °F) on the process wetted portion of the probe.
The switch responds to any material with a dielectric constant of
1.5 or more by detecting a change in oscillating frequency,
and it can be set to detect before contact or on contact with the
probe. The menu-driven setup allows precise control of the
switch point signal damping and alarm functions.
0
Pointek CLS200 digital version provides an integral LCD display
for stand-alone use, and also provides PROFIBUS PA communication (Profile version 3.0, Class B) for connection to a network.
Install probe at least 50 (2) from tank wall.
Pointek CLS200 installation, dimensions in mm (inch)
When connected to the PROFIBUS network, advanced diagnostics and set up using SIMATIC PDM are possible.
The CLS200 operates independently of the tank wall or pipe so it
does not require an external reference electrode for level detection in a non-conductive vessel such as concrete or plastic
(EMC regulations applicable in some regions).
• Key Applications: liquids, slurries, powders, granules,
pressurized applications, hazardous areas
Siemens FI 01 · 2015
4/27
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Digital
■ Technical specifications
Mode of operation
Measuring principle
Inverse frequency shift capacitive
level detection
Input
Measured variable
Change in picoFarad (pF)
Output
Output signal
• Solid-state output
- Output
- Protection
- Max. switching voltage
4
- Max. load current
- Voltage drop
- Time delay (ON and/or OFF)
• Fail-safe mode
• Connection
Galvanically isolated
Against reversed polarity (bipolar)
• 30 V (DC)
• 30 V peak (AC)
82 mA
< 1 V, typical at 50 mA
Programmable by user (0 ... 100 s)
Min. or max.
Removable terminal block
Power supply
Bus voltage
Standard: 12 ... 30 V DC
Current consumption
Intrinsically Safe: 12 ... 24 V DC
12.5 mA
Certificates and approvals
General Purpose
Dust Ignition Proof
Dust Ignition Proof with IS Probe
Flameproof Enclosure with IS Probe
Explosion Proof with IS Probe
Intrinsically Safe4)
Rated operating conditions1)
Installation conditions
• Location
Indoor/outdoor
Ambient conditions
• Ambient temperature
• Installation category
• Pollution degree
-40 ... +85 °C (-40 ... +185 °F)2)
II
4
Medium conditions
• Relative dielectric constant r
• Process temperature
Non-incendive
Liquids, bulk solids, slurries and
interfaces
Min. 1.5
-40 ... +85 °C (-40 ... +185 °F)2)
-40 ... +125 °C (-40 ... +257 °F)
-1 ... +25 bar g
(-14.6 ... +365 psi g) (nominal)
3)
-1 ... +10 bar g
• Process pressure (cable version)
(-14.6 ... +150 psi g) (nominal)
-1 ... +10 bar g
• Process pressure
(-14.6 ... +150 psi g) (nominal)
(sliding coupling version)
- Without thermal isolator
- With thermal isolator
• Process pressure (rod version)
Design
• Material
- Enclosure
- Optional thermal isolator
• Connection
• Degree of protection
• Cable inlet
Electromagnetic Compatibility
4/28
Siemens FI 01 · 2015
Epoxy-coated aluminum with gasket
316L stainless steel
Removable terminal block,
max. 2.5 mm²
IP65/Type 4/NEMA 4 (optional IP68)
2 x M20x1.5 thread
(option: 2 x ½" NPT conduit entry
including 1 plugged entry)
To comply with CE EMC regulations
(where applicable); the CLS200
should be installed per the instruction
manual.
Non-Sparking
Marine
Others
Communication
CSA, FM, CE, RCM
ATEX II 1/2 D T100 °C
CSA/FM Class II, Div. 1,
Groups E, F, G
CSA/FM Class III T4
ATEX II 1/2 G EEx d[ia] IIC T6...T4
ATEX II 1/2 D T100 °C
CSA/FM Class I,
Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1,
Groups E, F, G
CSA/FM Class III T4
ATEX II 1 G EEx ia IIC T6 ... T4
ATEX II 1/2 D IP6X T100 °C
CSA/FM Class I, Div. 1,
Groups A, B, C, D
CSA/FM Class II, Div. 1,
Groups E, F, G
CSA/FM Class III T4
CSA/FM Class I, Div. 2,
Groups A, B, C, D
CSA/FM Class II, Div. 2,
Groups F, G
CSA/FM Class III T4 or T6
ATEX II 3 G Ex nA II T6...T4
ATEX II 2 D IP6X T100 °C
Lloyds Register of Shipping,
Categories ENV1, ENV2 and ENV5
Pattern Approval (China)
PROFIBUS PA
(IEC 61158 CPF3 CP3/2)
Bus physical layer:
IEC 61158-2 MBP (IS)
Device profile: PROFIBUS PA
profile for Process Control
Devices Version 3.0, Class B
FISCO field device
1)
When operation is in areas classified as hazardous, observe restrictions
according to relevant certificate.
See also Pressure/Temperature curves on page 4/37.
2)
Thermal isolator is used if process connection temperature exceeds 85 °C
(185 °F)
3)
Pressure rating of process seal is temperature dependent.
See Pressure/Temperature curves on page 4/37.
4)
Barrier or Intrinsically Safe power supply required for Intrinsically Safe
protection
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Digital
Design: Probe
Rod version
Sanitary version
Cable version
Sliding Coupling version
Max. length
5 500 mm (216.53 inch)
5 500 mm (216.53 inch)
30 000 mm (1 181.1 inch)
liquids and slurries
5 000 mm (196.85 inch)
solids (under loads)
5 500 mm (216.53 inch)
Process
connection
R ¾", 1" , 1¼", 1½" [(BSPT),
1½", 2" sanitary fitting clamp
EN 10226/PT (JIS-T),
316L stainless steel
JIS B 0203]
¾", 1", 1¼", 1½" NPT
[(Taper), ANSI/ASME B1.20.1]
G ¾", 1", 1½" [(BSPP),
EN ISO 228-1/PF (JIS-P),
JIS B 0202]
316L stainless steel
ASME/EN flange
R ¾", 1", 1¼", 1½" [(BSPT),
EN 10226/PT (JIS-T),
JIS B 0203]
¾", 1", 1¼", 1½" NPT
[(Taper), ANSI/ASME B1.20.1]
G ¾", 1", 1½" [(BSPP),
EN ISO 228-1/PF (JIS-P),
JIS B 0202]
316L stainless steel
ASME/EN flange
R ¾", 1", 1¼", 1½ inch [(BSPT),
EN 10226/PT (JIS-T),
JIS B 0203]
¾", 1", 1¼", 1½" NPT
[(Taper), ANSI/ASME B1.20.1]
G ¾", 1", 1½" [(BSPP),
EN ISO 228-1/PF (JIS-P),
JIS B 0202]
Extension material
316L stainless steel
optional PFA coated1)
316L stainless steel
Fluoroethylene propylene
(FEP) cable with stainless
steel core
316L stainless steel
Sensor wetted parts
PPS (optional PVDF)
PPS (optional PVDF)
PPS (optional PVDF)
PPS (optional PVDF)
O-ring seal material
FKM (optional FFKM)2)
FKM (optional FFKM)2)
FKM (optional FFKM)2)
FKM (optional FFKM)2)
Thermal isolator3)
Optional
Optional
Optional
Optional
Extension
User selected length
User selected length
Cable extension
User selected length
1)
PFA coating (7ML5634 and 7ML5644) has 120 micron thickness
2)
For Caustic Materials, please contact [email protected] for alternative O-Rings
3)
Thermal isolator is used if process connection temperature exceeds 85 °C (185 °F).
Siemens FI 01 · 2015
4
4/29
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Digital
4
Selection and Ordering data
Pointek CLS200 - Digital - Rod
with Threaded or Flanged process connection
Versatile inverse frequency shift capacitance level
and material detection switch with optional process
connection choices and configurable output.
CLS200 is ideal for detection of liquids, solids,
slurries, foam, and interfaces, and has the ability to
tune out build-up on the probe.
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Process connection
Threaded, 316L stainless steel
¾" NPT [(Taper), ANSI/ASME B1.20.1]
¢
1" NPT [(Taper), ANSI/ASME B1.20.1]
¢
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
¢
1½" NPT [(Taper), ANSI/ASME B1.20.1]
¢
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
¢
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
¢
R 1½" [(BSPT), EN 10226/PT (JIS-T),
¢
JIS B 0203]
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]¢
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P),
¢
JIS B 0202]
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P),
¢
JIS B 0202]
Welded flange, 316L stainless steel, raised face
1" ASME, 150 lb
¢
1" ASME, 300 lb
1" ASME, 600 lb
1½" ASME, 150 lb
¢
1½" ASME, 300 lb
1½" ASME, 600 lb
2" ASME, 150 lb
¢
2" ASME, 300 lb
2" ASME, 600 lb
3" ASME, 150 lb
¢
3" ASME, 300 lb
3" ASME, 600 lb
4" ASME, 150 lb
¢
4" ASME, 300 lb
4" ASME, 600 lb
Welded flange, 316L stainless steel,
Type A flat faced
DN 25, PN 16
¢
DN 25, PN 40
DN 40, PN 16
¢
DN 40, PN 40
DN 50, PN 16
¢
DN 50, PN 40
DN 80, PN 16
¢
DN 80, PN 40
DN 100, PN 16
¢
DN 100, PN 40
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5 or EN 1092-1 standard.)
Probe length (length from flange face)
(threaded lengths include process thread)
Note: No Y01 needed in Order code for
standard lengths
Compact [threaded 120 mm (4.72 inch),
¢
Flanged 98 mm (3.86 inch)]
Extended rod, 250 mm (9.84 inch)
¢
Extended rod, 350 mm (13.78 inch)
¢
Extended rod, 500 mm (19.69 inch)
¢
Extended rod, 750 mm (29.53 inch)
¢
Extended rod, 1 000 mm (39.37 inch)
¢
Extended rod, 1 250 mm (49.21 inch)
¢
Extended rod, 1 350 mm (53.15 inch)
¢
Extended rod, 1 500 mm (59.06 inch)
¢
Extended rod, 1 750 mm (68.90 inch)
¢
Extended rod, 2 000 mm (78.74 inch)
¢
4/30
Siemens FI 01 · 2015
Article No.
7ML564077 7 77 - 77 7 0
0A
0B
0C
0D
1A
1B
1D
3A
3B
3D
5A
5B
5C
5D
5E
5F
5G
5H
5J
5K
5L
5M
5N
5P
5Q
6A
6B
6C
6D
6E
6F
6G
6H
6J
6K
A
B
C
D
E
F
G
H
J
K
L
Selection and Ordering data
Article No.
Pointek CLS200 - Digital - Rod
7ML5640with Threaded or Flanged process connection
7 7 7 77 - 77 7 0
Versatile inverse frequency shift capacitance level
and material detection switch with optional process
connection choices and configurable output.
CLS200 is ideal for detection of liquids, solids,
slurries, foam, and interfaces, and has the ability to
tune out build-up on the probe.
Add Order code Y01 and plain text:
"Insertion length ... mm"
Extended rod, 210 ... 1 000 mm (8.27 ... 39.37 inch) ¢
M
Extended rod, 1 001 ... 2 000 mm
¢
N
(39.41 ... 78.74 inch)
Extended rod, 2 001 ... 3 000 mm
¢
P
(78.78 ... 118.11 inch)
Extended rod, 3 001 ... 4 000 mm
¢
Q
(118.15 ... 157.48 inch)
Extended rod, 4 001 ... 5 000 mm
¢
R
(157.52 ... 196.85 inch)
Extended rod, 5 001 ... 5 500 mm
¢
S
(196.89 ... 216.53 inch)
Thermal isolator
Without thermal isolator
¢
0
With thermal isolator [for process connection
¢
1
temperatures over 85 °C (185 °F)]
Remote mount electronics and
mounting bracket
With 2 m (79 inch) of cable
¢
2
With 5 m (197 inch) of cable
¢
3
Wetted seals
FKM
¢
0
FFKM [for process temperatures above
¢
1
-20 °C (-4 °F)]
Probe material
316L stainless steel with PPS probe body
¢
0
316L stainless steel with PVDF probe body
¢
1
Approvals
Non-Sparking:
¢
B
CE, RCM, ATEX II 3 G Ex nA II T6...T4,
ATEX II 2 D IP6X T100 °C
Dust Ignition Proof:
¢
C
CE, RCM, ATEX II 1/2 D T100 °C
Intrinsically Safe:1)
D
¢
CE, RCM, ATEX II 1 G EEx ia IIC T6...T4,
ATEX II 1/2 D IP6X T100 °C
Flameproof Enclosure with IS Probe:
¢
E
CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T4,
ATEX II 1/2 D T100 °C
Non-incendive:
¢
F
CSA/FM Class I, Div. 2, Groups A, B, C, D
CSA/FM Class II, Div. 2, Groups F, G
CSA/FM Class III T4 or T6
Dust Ignition Proof with IS Probe:
¢
G
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
¢
Intrinsically Safe:1)
H
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
Explosion Proof with IS Probe:
¢
J
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
General Purpose (CSA, FM)
¢
K
General Purpose (CE, RCM)
¢
L
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Digital
Selection and Ordering data
Article No.
Pointek CLS200 - Digital - Rod
7ML5640with Threaded or Flanged process connection
77 7 77 - 77 7 0
Versatile inverse frequency shift capacitance level
and material detection switch with optional process
connection choices and configurable output.
CLS200 is ideal for detection of liquids, solids,
slurries, foam, and interfaces, and has the ability to
tune out build-up on the probe.
Enclosure and lid
Aluminum epoxy coated
2 x ½" NPT via adapter - cable inlet, IP65
¢
A
2 x M20x1.5 cable inlet, IP65
¢
B
2 x ½" NPT via adapter - cable inlet, IP68
¢
C
2 x M20x1.5 cable inlet, IP68
¢
D
1)
Barrier or Intrinsically Safe power supply required for Intrinsically Safe
protection
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Selection and Ordering data
Order code
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
Total insertion length: enter the total insertion length ¢ Y01
in plain text description
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Measuring-point number/identification
(max. 27 characters) specify in plain text
Manufacturer's test certificate: M to DIN 55350,
Part 18 and ISO 9000
¢ C11
Inspection Certificate Type 3.1 per EN 10204
¢ C12
Operating Instructions
Note: The Operating Instructions should be
ordered as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
manual library.
See page 4/36
Accessories
See page 4/36
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Selection and Ordering data
Article No.
Pointek CLS200 - Digital - Cable with
Threaded or Flanged process connection
Versatile inverse frequency shift capacitance level
and material detection switch with optional process
connection choices and configurable output.
CLS200 is ideal for detection of liquids, solids,
slurries, foam, and interfaces, and has the ability to
tune out build-up on the probe.
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Process connection
Threaded, 316L stainless steel
¾" NPT [(Taper), ANSI/ASME B1.20.1]
¢
1" NPT [(Taper), ANSI/ASME B1.20.1]
¢
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
¢
1½" NPT [(Taper), ANSI/ASME B1.20.1]
¢
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
¢
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
¢
R 1½" [(BSPT), EN 10226/PT (JIS-T),
¢
JIS B 0203]
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P),
¢
JIS B 0202]
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P),
¢
JIS B 0202]
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P),
¢
JIS B 0202]
Welded flange, 316L stainless steel, raised face
1" ASME, 150 lb
¢
1" ASME, 300 lb
1" ASME, 600 lb
1½" ASME, 150 lb
¢
1½" ASME, 300 lb
1½" ASME, 600 lb
2" ASME, 150 lb
¢
2" ASME, 300 lb
2" ASME, 600 lb
3" ASME, 150 lb
¢
3" ASME, 300 lb
3" ASME, 600 lb
4" ASME, 150 lb
¢
4" ASME, 300 lb
4" ASME, 600 lb
Welded flange, 316L stainless steel,
Type A flat faced
DN 25, PN 16
¢
DN 25, PN 40
DN 40, PN 16
¢
DN 40, PN 40
DN 50, PN 16
¢
DN 50, PN 40
DN 80, PN 16
¢
DN 80, PN 40
DN 100, PN 16
¢
DN 100, PN 40
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5 or EN 1092-1 standard.)
7ML56417 7 7 77 - 77 7 0
0A
0B
0C
0D
1A
1B
1D
4
3A
3B
3D
5A
5B
5C
5D
5E
5F
5G
5H
5J
5K
5L
5M
5N
5P
5Q
6A
6B
6C
6D
6E
6F
6G
6H
6J
6K
Siemens FI 01 · 2015
4/31
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Digital
Selection and Ordering data
4
Article No.
Pointek CLS200 - Digital - Cable with
7ML5641Threaded or Flanged process connection
77 7 77 - 77 7 0
Versatile inverse frequency shift capacitance level
and material detection switch with optional process
connection choices and configurable output.
CLS200 is ideal for detection of liquids, solids,
slurries, foam, and interfaces, and has the ability to
tune out build-up on the probe.
Probe length (length from flange face)
(threaded lengths include process thread)
Note: No Y01 needed in Order code for
standard lengths
Extended cable, 3 000 mm (118.11 inch), length ¢
A
can be determined by customer on assembly
Extended cable, 6 000 mm (236.22 inch), length ¢
B
can be determined by customer on assembly
Add Order code Y01 and plain text:
"Insertion length ... mm"
Extended cable, 500 ... 5 000 mm
¢
C
(19.69 ... 196.85 inch)
Extended cable, 5 001 ... 10 000 mm
¢
D
(196.89 ... 393.70 inch)
Extended cable, 10 001 ... 15 000 mm
¢
E
(393.74 ... 590.55 inch)
Extended cable, 15 001 ... 20 000 mm
¢
F
(590.59 ... 787.40 inch)
Extended cable, 20 001 ... 25 000 mm
¢
G
(787.44 ... 984.25 inch)
Extended cable, 25 001 ... 30 000 mm
¢
H
(984.29 ... 1 181.10 inch)
Thermal isolator
Without thermal isolator
¢
0
With thermal isolator [for process connection
¢
1
temperatures over 85 °C (185 °F)]
Remote mount electronics and
mounting bracket
With 2 m (79 inch) of cable
¢
2
With 5 m (197 inch) of cable
¢
3
Wetted seals
FKM and PTFE
¢
0
FFKM and PTFE [for process temperatures
¢
1
above -20 °C (-4 °F)]
Probe material
FEP jacketed cable with PPS probe body
¢
0
FEP jacketed cable with PVDF probe body
¢
1
Approvals
Non-Sparking:
¢
B
CE, RCM, ATEX II 3 G Ex nA II T6...T4,
ATEX II 2 D IP6X T100 °C
Dust Ignition Proof:
¢
C
CE, RCM, ATEX II 1/2 D T100 °C
Intrinsically Safe:1)
D
¢
CE, RCM, ATEX II 1 G EEx ia IIC T6...T4,
ATEX II 1/2 D IP6X T100 °C
Flameproof Enclosure with IS Probe:
¢
E
CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T4,
ATEX II 1/2 D T100 °C
Non-incendive:
¢
F
CSA/FM Class I, Div. 2, Groups A, B, C, D
CSA/FM Class II, Div. 2, Groups F, G
CSA/FM Class III T4 or T6
Dust Ignition Proof with IS Probe:
¢
G
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
Intrinsically Safe:1)
H
¢
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
Explosion Proof with IS Probe:
¢
J
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
General Purpose (CSA, FM)
¢
K
General Purpose (CE, RCM)
¢
L
4/32
Siemens FI 01 · 2015
Selection and Ordering data
Article No.
Pointek CLS200 - Digital - Cable with
7ML5641Threaded or Flanged process connection
7 7 7 77 - 77 7 0
Versatile inverse frequency shift capacitance level
and material detection switch with optional process
connection choices and configurable output.
CLS200 is ideal for detection of liquids, solids,
slurries, foam, and interfaces, and has the ability to
tune out build-up on the probe.
Enclosure and lid
Aluminum epoxy coated
2 x ½" NPT via adapter - cable inlet, IP65
¢
A
2 x M20x1.5 cable inlet, IP65
¢
B
2 x ½" NPT via adapter - cable inlet, IP68
¢
C
2 x M20x1.5 cable inlet, IP68
¢
D
1)
Barrier or Intrinsically Safe power supply required for Intrinsically Safe
protection
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Selection and Ordering data
Order code
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
Total insertion length: enter the total insertion length ¢ Y01
in plain text description
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Measuring-point number/identification
(max. 27 characters) specify in plain text
Manufacturer's test certificate: M to DIN 55350,
Part 18 and ISO 9000
¢ C11
Inspection Certificate Type 3.1 per EN 10204
¢ C12
Operating Instructions
Note: The Operating Instructions should be
ordered as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
manual library.
See page 4/36
Accessories
See page 4/36
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Digital
Selection and Ordering data
Pointek CLS200 - Digital - Rod with
Sanitary process connection
Versatile inverse frequency shift capacitance level
and material detection switch with optional process
connection choices and configurable output.
CLS200 is ideal for detection of liquids, solids,
slurries, foam, and interfaces, and has the ability to
tune out build-up on the probe.
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Process connection
Sanitary 316L stainless steel
1" sanitary fitting clamp
¢
1½" sanitary fitting clamp
2" sanitary fitting clamp
2½" sanitary fitting clamp
¢
3" sanitary fitting clamp
(Note: Sanitary connection dimensionally
corresponds to the applicable ISO 2852 standard.)
Probe length (length from process connection face)
Note: No Y01 needed in Order code for
standard lengths
Compact 98 mm (3.86 inch)
¢
Extended rod, 250 mm (9.84 inch)
¢
Extended rod, 350 mm (13.78 inch)
¢
Extended rod, 500 mm (19.69 inch)
¢
Extended rod, 750 mm (29.53 inch)
¢
Extended rod, 1 000 mm (39.37 inch)
¢
Extended rod, 1 250 mm (49.21 inch)
¢
Extended rod, 1 350 mm (53.15 inch)
¢
Extended rod, 1 500 mm (59.06 inch)
¢
Extended rod, 1 750 mm (68.90 inch)
¢
Extended rod, 2 000 mm (78.74 inch)
¢
Add Order code Y01 and plain text:
"Insertion length ... mm"
Extended rod, 110 ... 350 mm (4.3 ... 13.78 inch) ¢
Extended rod, 351 ... 1 000 mm
¢
(13.82 ... 39.37 inch)
Extended rod, 1 001 ... 2 000 mm
¢
(39.41 ... 78.74 inch)
Extended rod, 2 001 ... 3 000 mm
¢
(78.78 ... 118.11 inch)
Extended rod, 3 001 ... 4 000 mm
¢
(118.15 ... 157.48 inch)
Extended rod, 4 001 ... 5 000 mm
¢
(157.52 ... 196.85 inch)
Extended rod, 5 001 ... 5 500 mm
¢
(196.89 ... 216.53 inch)
Thermal isolator
Without thermal isolator
¢
With thermal isolator [for process connection
¢
temperatures over 85 °C (185 °F)]
Remote mount electronics and
mounting bracket
With 2 m (79 inch) of cable
¢
With 5 m (197 inch) of cable
¢
Wetted seals
FKM
¢
FFKM [for process temperatures above -20 °C (-4 °F)]¢
Probe material
316L stainless steel with PPS probe body
¢
316L stainless steel with PVDF probe body
¢
Approvals
Non-Sparking:
CE, RCM, ATEX II 3 G Ex nA II T6...T4,
ATEX II 2 D IP6X T100 °C
Dust Ignition Proof:
CE, RCM, ATEX II 1/2 D T100 °C
Intrinsically Safe:1)
CE, RCM, ATEX II 1 G EEx ia IIC T6...T4,
ATEX II 1/2 D IP6X T100 °C
Flameproof Enclosure with IS Probe:
CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T4,
ATEX II 1/2 D T100 °C
Article No.
7ML564277 7 77 - 777 0
8A
8B
8C
8D
8E
A
B
C
D
E
F
G
H
J
K
L
Selection and Ordering data
Article No.
7ML5642Pointek CLS200 - Digital - Rod with
Sanitary process connection
7 7 7 77 - 77 7 0
Versatile inverse frequency shift capacitance level
and material detection switch with optional process
connection choices and configurable output.
CLS200 is ideal for detection of liquids, solids,
slurries, foam, and interfaces, and has the ability to
tune out build-up on the probe.
Non-incendive:
¢
F
CSA/FM Class I, Div. 2, Groups A, B, C, D
CSA/FM Class II, Div. 2, Groups F, G
CSA/FM Class III T4 or T6
Dust Ignition Proof with IS Probe:
¢
G
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
¢
Intrinsically Safe:1)
H
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
Explosion Proof with IS Probe:
¢
J
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
General Purpose (CSA, FM)
¢
K
General Purpose (CE, RCM)
¢
L
Enclosure and lid
Aluminum epoxy coated
2 x ½" NPT via adapter - cable inlet, IP65
2 x M20x1.5 cable inlet, IP65
2 x ½" NPT via adapter - cable inlet, IP68
2 x M20x1.5 cable inlet, IP68
1)
¢
¢
¢
¢
A
B
C
D
Barrier or Intrinsically Safe power supply required for Intrinsically Safe
protection
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
M
N
Selection and Ordering data
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
Total insertion length: enter the total insertion length ¢
in plain text description
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢
Measuring-point number/identification
(max. 27 characters) specify in plain text
Manufacturer's test certificate: M to DIN 55350,
¢
Part 18 and ISO 9000
Inspection Certificate Type 3.1 per EN 10204
¢
Operating Instructions
Note: The Operating Instructions should be
ordered as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
manual library.
Accessories
P
Q
R
S
T
0
1
2
3
0
1
Order code
Y01
Y15
C11
C12
See page 4/36
See page 4/36
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
0
1
¢
B
¢
C
¢
D
¢
E
Siemens FI 01 · 2015
4/33
4
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Digital
4
Selection and Ordering data
Article No.
Selection and Ordering data
Pointek CLS200 - Digital - Rod with Sliding
coupling with Threaded process connection
Versatile inverse frequency shift capacitance level
and material detection switch with optional process
connection choices and configurable output.
CLS200 is ideal for detection of liquids, solids,
slurries, foam, and interfaces, and has the ability to
tune out build-up on the probe.
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Process connection
Threaded, 316L stainless steel
¾" NPT [(Taper), ANSI/ASME B1.20.1]
¢
1" NPT [(Taper), ANSI/ASME B1.20.1]
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
1½" NPT [(Taper), ANSI/ASME B1.20.1]
¢
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
R 1½" [(BSPT), EN 10226/PT (JIS-T),
JIS B 0203]
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
Probe length (length from flange face)
(threaded lengths include process thread)
Note: No Y01 needed in Order code for
standard lengths
Extended rod, 350 mm (13.78 inch)
¢
Extended rod, 500 mm (19.69 inch)
¢
Extended rod, 750 mm (29.53 inch)
¢
Extended rod, 1 000 mm (39.37 inch)
¢
Extended rod, 1 250 mm (49.21 inch)
¢
Extended rod, 1 350 mm (53.15 inch)
¢
Extended rod, 1 500 mm (59.06 inch)
¢
Extended rod, 1 750 mm (68.90 inch)
¢
Extended rod, 2 000 mm (78.74 inch)
¢
Add Order code Y01 and plain text:
"Insertion length ... mm"
Extended rod, 350 ... 1 000 mm
¢
(13.82 ... 39.37 inch)
Extended rod, 1 001 ... 2 000 mm
¢
(39.41 ... 78.74 inch)
Extended rod, 2 001 ... 3 000 mm
¢
(78.78 ... 118.11 inch)
Extended rod, 3 001 ... 4 000 mm
¢
(118.15 ... 157.48 inch)
Extended rod, 4 001 ... 5 000 mm
¢
(157.52 ... 196.85 inch)
Extended rod, 5 001 ... 5 500 mm
¢
(196.89 ... 216.53 inch)
Thermal isolator
Without thermal isolator
¢
With thermal isolator [for process connection
¢
temperatures over 85 °C (185 °F)]
Remote mount electronics and
mounting bracket
With 2 m (79 inch) of cable
¢
With 5 m (197 inch) of cable
¢
Wetted seals
FKM and PTFE
¢
FFKM and PTFE [for process temperatures above ¢
-20 °C (-4 °F)]
Probe material
316L stainless steel with PPS probe body
¢
316L stainless steel with PVDF probe body
¢
Approvals
Non-Sparking:
¢
CE, RCM, ATEX II 3 G Ex nA II T6...T4,
ATEX II 2 D IP6X T100 °C
Dust Ignition Proof:
¢
CE, RCM, ATEX II 1/2 D T100 °C
1)
Intrinsically Safe:
¢
CE, RCM, ATEX II 1 G EEx ia IIC T6...T4,
ATEX II 1/2 D IP6X T100 °C
7ML564377 7 77 - 77 7 0
Pointek CLS200 - Digital - Rod with Sliding
7ML5643coupling with Threaded process connection
7 7 7 77 - 77 7 0
Versatile inverse frequency shift capacitance level
and material detection switch with optional process
connection choices and configurable output.
CLS200 is ideal for detection of liquids, solids,
slurries, foam, and interfaces, and has the ability to
tune out build-up on the probe.
Flameproof Enclosure with IS Probe:
¢
E
CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T4,
ATEX II 1/2 D T100 °C
Non-incendive:
¢
F
CSA/FM Class I, Div. 2, Groups A, B, C, D
CSA/FM Class II, Div. 2, Groups F, G
CSA/FM Class III T4 or T6
Dust Ignition Proof with IS Probe:
¢
G
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
Intrinsically Safe:1)
¢
H
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
Explosion Proof with IS Probe:
¢
J
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
General Purpose (CSA, FM)
¢
K
General Purpose (CE, RCM)
¢
L
Enclosure and lid
Aluminum epoxy coated
2 x ½" NPT via adapter - cable inlet, IP65
¢
A
2 x M20x1.5 cable inlet, IP65
¢
B
2 x ½" NPT via adapter - cable inlet, IP68
¢
C
2 x M20x1.5 cable inlet, IP68
¢
D
4/34
Siemens FI 01 · 2015
0A
0B
0C
0D
1A
1B
1D
3A
3B
3D
C
D
E
F
G
H
J
K
L
1)
Article No.
Barrier or Intrinsically Safe power supply required for Intrinsically Safe
protection
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Selection and Ordering data
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
Total insertion length: enter the total insertion length ¢
in plain text description
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢
Measuring-point number/identification
(max. 27 characters) specify in plain text
Manufacturer's test certificate: M to DIN 55350,
¢
Part 18 and ISO 9000
Inspection Certificate Type 3.1 per EN 10204
¢
Operating Instructions
Note: The Operating Instructions should be
ordered as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
manual library.
Accessories
M
N
P
Q
R
S
0
1
2
3
0
1
Order code
Y01
Y15
C11
C12
See page 4/36
See page 4/36
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
0
1
B
C
D
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Digital
Selection and Ordering data
Article No.
Selection and Ordering data
Article No.
Pointek CLS200 - Digital - PFA Rod with
PFA Flanged process connection
Versatile inverse frequency shift capacitance level
and material detection switch with optional process
connection choices and configurable output.
CLS200 is ideal for detection of liquids, solids,
slurries, foam, and interfaces, and has the ability to
tune out build-up on the probe.
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Process connection
Welded flange, PFA coated, 316L stainless steel,
raised face
1" ASME, 150 lb
1" ASME, 300 lb
1" ASME, 600 lb
1½" ASME, 150 lb
1½" ASME, 300 lb
1½" ASME, 600 lb
2" ASME, 150 lb
2" ASME, 300 lb
2" ASME, 600 lb
3" ASME, 150 lb
3" ASME, 300 lb
3" ASME, 600 lb
4" ASME, 150 lb
4" ASME, 300 lb
4" ASME, 600 lb
Welded flange, PFA coated, 316L stainless steel,
Type A flat faced
DN 25, PN 16
DN 25, PN 40
DN 40, PN 16
DN 40, PN 40
DN 50, PN 16
DN 50, PN 40
DN 80, PN 16
DN 80, PN 40
DN 100, PN 16
DN 100, PN 40
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5 or EN 1092-1 standard.)
Probe length (length from process connection
face)
Note: No Y01 needed in Order code for
standard lengths
Compact 98 mm (3.86 inch)
Extended rod, 250 mm (9.84 inch)
Extended rod, 350 mm (13.78 inch)
Extended rod, 500 mm (19.69 inch)
Extended rod, 750 mm (29.53 inch)
Extended rod, 1 000 mm (39.37 inch)
Extended rod, 1 250 mm (49.21 inch)
Extended rod, 1 350 mm (53.15 inch)
Extended rod, 1 500 mm (59.06 inch)
Extended rod, 1 750 mm (68.90 inch)
Extended rod, 2 000 mm (78.74 inch)
Add Order code Y01 and plain text:
"Insertion length ... mm"
Extended rod, 200 ... 1 000 mm (7.87 ... 39.37 inch)
Extended rod, 1 001 ... 2 000 mm
(39.41 ... 78.74 inch)
Extended rod, 2 001 ... 3 000 mm
(78.78 ... 118.11 inch)
Extended rod, 3 001 ... 4 000 mm
(118.15 ... 157.48 inch)
Extended rod, 4 001 ... 5 000 mm
(157.52 ... 196.85 inch)
Extended rod, 5 001 ... 5 500 mm
(196.89 ... 216.53 inch)
Thermal isolator
Without thermal isolator
With thermal isolator [for process connection
temperatures over 85 °C (185 °F)]
7ML564477 7 77 - 77 7 0
Pointek CLS200 - Digital - PFA Rod with
PFA Flanged process connection
Versatile inverse frequency shift capacitance level
and material detection switch with optional process
connection choices and configurable output.
CLS200 is ideal for detection of liquids, solids,
slurries, foam, and interfaces, and has the ability to
tune out build-up on the probe.
Remote mount electronics and
mounting bracket
With 2 m (79 inch) of cable
With 5 m (197 inch) of cable
Wetted seals
FKM
FFKM [for process temperatures above
-20 °C (-4 °F)]
Probe material
PFA Coated 316L stainless steel with PPS probe
body
PFA Coated 316L stainless steel with PVDF probe
body
Approvals
Non-incendive:
CSA/FM Class I, Div. 2, Groups A, B, C, D
CSA/FM Class II, Div. 2, Groups F, G
CSA/FM Class III T4 or T6
Dust Ignition Proof with IS Probe:
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
Intrinsically Safe:1)
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
Explosion Proof with IS Probe:
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
General Purpose (CSA, FM)
Enclosure and lid
Aluminum epoxy coated
2 x ½" NPT via adapter - cable inlet, IP65
2 x M20x1.5 cable inlet, IP65
2 x ½" NPT via adapter - cable inlet, IP68
2 x M20x1.5 cable inlet, IP68
7ML56447 7 7 77 - 77 7 0
5A
5B
5C
5D
5E
5F
5G
5H
5J
5K
5L
5M
5N
5P
5Q
6A
6B
6C
6D
6E
6F
6G
6H
6J
6K
1)
A
B
C
D
E
F
G
H
J
K
L
2
3
0
1
4
0
1
F
G
H
J
K
A
B
C
D
Barrier or Intrinsically Safe power supply required for Intrinsically Safe
protection
Order code
Selection and Ordering data
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
M
N
P
Total insertion length: enter the total insertion length
in plain text description
Y01
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 27 characters) specify in plain text
Y15
Manufacturer's test certificate: M to DIN 55350,
Part 18 and ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Operating Instructions
Note: The Operating Instructions should be
ordered as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
manual library.
Q
R
S
Accessories
See page 4/36
See page 4/36
0
1
Siemens FI 01 · 2015
4/35
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Standard and Digital
Selection and Ordering data
Article No.
■ Options
Operating Instructions - Standard
4
English
7ML1998-5JJ05
German
7ML1998-5JJ34
French
7ML1998-5JJ11
Note: The Operating Instructions should be
ordered as a separate line on the order.
Quick Start manual, multi-language
Optional SensGuard, dimensions in mm (inch)
A5E32221496
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
Accessories
SensGuard, ¾" NPT (PPS)
Only available for CLS200 with ¾" NPT thread
7ML1830-1DL
SensGuard, R 1" (BSPT) (PPS)
Only available for CLS200 with ¾" NPT thread
7ML1830-1DM
One metallic cable gland M20x1.5, -40 ... +80 °C
(-40 ... +176 °F) with integrated shield connection
(available for PROFIBUS PA)
7ML1930-1AQ
General Purpose
1/2" NPT General Purpose Cable Entry IP68/IP69K
NEMA6, -40 ... -100 °C (-40 ... -212 °F),
cable size 6 ... 12 mm (0.236 ... 0.472 inch)
7ML1830-1JA
M20x1.5 General Purpose Cable Entry IP68/IP69K
NEMA6,-40 ... -100 °C (-40 ... -212 °F),
cable size 7 ... 12 mm (0.275 ... 0.472 inch)
7ML1830-1JC
Hazardous Locations
1/2" NPT EMC rated Cable Gland: Dust Ignition
Proof, Flameproof Exd, and Increased Safety ATEX
II 2 GD ExtD A21 (Zone 1, Zone 2, Zone 21,
Zone 22, and in Gas Groups IIA,IIB and IIC)
-60 ... +80 °C IP66, IP67, IP68, NEMA4X,
cable sizes 5.5 ... 12 mm (0.216 ... 0.472 inch)
7ML1830-1JB
M20 EMC rated Cable Gland: Dust Ignition Proof,
Flameproof Exd, and Increased Safety ATEX II 2
GD ExtD A21 (Zone 1, Zone 2, Zone 21, Zone 22
and in Gas Groups IIA, IIB and IIC)
-60 ... +80 °C IP66, IP67, IP68, NEMA4X,
cable sizes 5.5 ... 12 mm (0.216 ... 0.472 inch)
7ML1830-1JD
Blind threaded flanges are available.
Please contact [email protected] with a
completed application data sheet on page 4/11
Pointek Specials
4/36
Siemens FI 01 · 2015
91 (3.6)
Operating Instructions - Digital
Process
connection
¾" NPT
See page 4/80
Process
connection
R 1" (BSPT)
70 (2.75)
A5E32221251
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
32
(1.26)
Quick Start manual, multi-language
Optional SensGuard
Internal thread ¾" NPT
91 (3.6)
7ML1998-5JH34
70 (2.75)
7ML1998-5JH04
German
Note: The Operating Instructions should be
ordered as a separate line on the order.
32
(1.26)
English
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Standard and Digital
■ Characteristic curves
Pressure/temperature curve
CLS200 sliding coupling
threaded process connections
(7ML5633 and 7ML5643)
Permitted operating pressures P
30 bar (435 psi)
20 bar (290 psi)
10 bar (145 psi)
4
Atmospheric
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
-29 ºC
(-20 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
Permitted operating temperature T
Example:
Permitted operating pressure = 10 bar (145 psi) at 75 °C
Pointek CLS200 Process Pressure/Temperature derating curves (7ML5633 and 7ML5643)
Pressure/temperature curve
CLS200 cable
Threaded process connections
(7ML5631 and 7ML5641)
Permitted operating pressures P
30 bar (435 psi)
20 bar (290 psi)
10 bar (145 psi)
Atmospheric
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
-29 ºC
(-20 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
Permitted operating temperature T
Pointek CLS200 Process Pressure/Temperature derating curves (7ML5631 and 7ML5641)
Siemens FI 01 · 2015
4/37
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Standard and Digital
Pressure/temperature curve
CLS200 compact and extended rod
Threaded process connections
(7ML5630 and 7ML5640)
Permitted operating pressures P
40 bar (580 psi)
30 bar (435 psi)
20 bar (290 psi)
4
10 bar (145 psi)
Atmospheric
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
-29 ºC
(-20 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
Permitted operating temperature T
Pointek CLS200 Process Pressure/Temperature derating curves (7ML5630 or 7ML5640)
Pressure/temperature curve
CLS200 compact and extended sanitary type
Sanitary process connections
(7ML5632 and 7ML5642)
Permitted operating pressures P
30 bar (435 psi)
20 bar (290 psi)
10 bar (145 psi)
Atmospheric
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
-29 ºC
(-20 ºF)
Pointek CLS200 Process Pressure/Temperature derating curves (7ML5632 and 7ML5642)
4/38
Siemens FI 01 · 2015
300 ºF
(149 ºC)
150 ºC
(302 ºF)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
Permitted operating temperature T
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Standard and Digital
Pressure/temperature curve
CLS200 cable
ASME flanged process connections
(7ML5631 and 7ML5641)
Permitted operating pressures P
30 bar (435 psi)
20 bar (290 psi)
Atmospheric
10 bar (145 psi)
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
ASME 150 lb1)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
-29 ºC
(-20 ºF)
1)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
4
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted operating temperature T
The curve denotes the minimum allowable flange class for the shaded area below.
Pointek CLS200 Process Pressure/Temperature derating curves (7ML5631 and 7ML5641)
Pressure/temperature curve
CLS200 compact and extended rod
ASME flanged process connections
(7ML5630 and 7ML5640)
Permitted operating pressures P
50 bar (725 psi)
40 bar (580 psi)
30 bar (435 psi)
ASME 300 lb1)
20 bar (290 psi)
Atmospheric
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
ASME 150 lb1)
10 bar (145 psi)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
-29 ºC
(-20 ºF)
1)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted operating temperature T
The curve denotes the minimum allowable flange class for the shaded area below.
Pointek CLS200 Process Pressure/Temperature derating curves (7ML5630 and 7ML5640)
Siemens FI 01 · 2015
4/39
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Standard and Digital
Pressure/temperature curve
CLS200 cable
EN flanged process connections
(7ML5631 and 7ML5641)
Permitted operating pressures P
30 bar (435 psi)
20 bar (290 psi)
10 bar (145 psi)
PN 161)
Atmospheric
4
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
-29 ºC
(-20 ºF)
1)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted operating temperature T
The curve denotes the minimum allowable flange class for the shaded area below.
Pointek CLS200 Process Pressure/Temperature derating curves (7ML5631 and 7ML5641)
Pressure/Temperature Curve
CLS200 Compact and Extended Rod
EN Flanged Process Connections
(7ML5630 and 7ML5640)
Permitted Operating Pressures P
50 bar (725 psi)
40 bar (580 psi)
30 bar (435 psi)
PN 401)
20 bar (290 psi)
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
PN 161)
10 bar (145 psi)
Atmospheric
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
-29 ºC
(-20 ºF)
1)
The curve denotes the minimum allowable flange class for the shaded area below.
Pointek CLS200 Process Pressure/Temperature derating curves (7ML5630 and 7ML5640)
4/40
Siemens FI 01 · 2015
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted Operating Temperature T
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Standard and Digital
■ Dimensional drawings
Compact version
Threaded
(7ML5630 and 7ML5640)
Extended cable version
Threaded
(7ML5631 and 7ML5641)
Extended rod version
Threaded
(7ML5630 and 7ML5640)
Y01 (insertion length)
Sanitary compact version
Sanitary fitting
(7ML5632 and 7ML5642)
316L stainless
steel extension
Y01 (insertion length)
PPS or optional
PVDF probe
Ø20 (0.79)
84
(3.3)
22
(0.87)
PPS or optional
PVDF probe
Min. insertion length = 200 (7.87)
Max. insertion length = 5 500 (216)
98
(3.8)
316L stainless steel
sensor weight
84
(3.3)
PPS or optional
PVDF probe
Min. insertion length = 500 (19.69)
Max. insertion length = 30 000 (1 181)
Applicable for liquids and solids
applications. Cable can be shortened
on site.
PPS or optional
PVDF probe
Sanitary extended version
Sanitary fitting
(7ML5632 and 7ML5642)
Sliding coupling version
Threaded
(7ML5633 and 7ML5643)
316L stainless
steel sliding
coupling
Ø24 (0.95)
PPS or optional
PVDF probe
Min. insertion length = 110 (4.3)
Max. insertion length = 5 500 (216)
Y01 (insertion length)
316L stainless
steel extension
98
(3.8)
252 (9.92)
316L stainless steel
sanitary process
connection
Ø20 (0.79)
84
(3.3)
Thermal
isolator
239 (9.41)
151
(5.94)
Lid without window
Y01 (insertion length)
M20: 135 (5.32)
½" NPT: 150 (5.91)
Lid with window
164 (6.46)
4
Ø20 (0.79)
316L stainless steel
sanitary process
connection
2 cable entries
½" NPT or
M20 x 1.5
FEP insulated
cable Ø6 (0.3)
Min. 215
(8.46)
120
(4.7)
Electronics/
enclosure
PPS or optional
PVDF probe
Min. insertion length = 350 (13.82)
Max. insertion length = 5 500 (216)
Pointek CLS200 - Threaded/sanitary process connections, dimensions in mm (inch)
Siemens FI 01 · 2015
4/41
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Standard and Digital
Compact version
Welded Flange (7ML5630 and 7ML5640)
Welded Flange, PFA coated
(7ML5634 and 7ML5644)
Extended rod version
Welded Flange (7ML5630 and 7ML5640)
Welded Flange, PFA coated
(7ML5634 and 7ML5644)
Extended cable version
Welded Flange
(7ML5631 and 7ML5641)
PPS or optional
PVDF probe
Min. insertion length = 200 (7.87)
Max. insertion length = 5 500 (216)
164 (6.46)
lid with window
316L stainless steel
sensor weight
Ø20 (0.79)
PPS or optional
PVDF probe
Min. insertion length = 500 (19.69)
Max. insertion length = 30 000 (1 181)
Applicable for liquids and solids applications. Cable can be shortened on site.
239 (9.41)
252 (9.92)
Lid without window
Thermal
isolator
FEP insulated
cable Ø6 (0.3)
84
(3.3)
M20: 135 (5.32)
½" NPT: 150 (5.91)
Ø20 (0.79)
Y01 (insertion length)
2 cable entries
½" NPT or
M20 x 1.5
316L stainless
steel extension
(or PFA coated
84
(3.3)
PPS or optional
PVDF probe
151
(5.94)
4
Y01 (insertion length)
98
(3.8)
Electronics/
enclosure
Flange Facing (raised face)
Flange Class
Facing thickness
ASME 150/300
2 (0.08)
ASME 600/900
7 (0.28)
PN16/40
2 (0.08)
Insertion length does not include any raised face/gasket face dimension
(see Flange Facing Table above)
Pointek CLS200 - Flanged Process Connections, dimensions in mm (inch)
4/42
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Standard and Digital
■ Schematics
Wiring: Pointek CLS200 standard
White
Black
Red
P2
(f )
(+)
Switch bank
Trip
point
S1
P1
K1
OFF
GND
3
+
Delay
2
1
K4
Sensor
L1
L2
L3
Sensor
status
Power
on
1
2
3
Power
supply
12 to 250 V AC/DC
Output
status
NC
NO
4
NO
K3
K2
Solid state switch:
30 V DC/30 V AC
(peak),
82 mA max.
Relay contact:
8 A at 250 V AC, 2 000 VA
5 A at 30 V DC, 150 W
Notes:
- Identification label is on underside of lid. Switch and potentiometer settings
are for illustration purposes only (refer to operation/setup in manual).
- All field wiring must have insulation suitable for at least 250 V.
- Relay contact terminals are for use with equipment having no accessible live
parts and wiring having insulation suitable for at least 250 V.
- Maximum working voltage between adjacent relay contacts shall be 250 V.
- Refer to the Instruction Manual or contact Siemens representative for detailed
wiring information.
Wiring: Pointek CLS200 Digital
White
Test input
Reed
contact*
White
Red (+)
Black (-)
Sensor
Alarm output
solid-state switch
Orange (f)
24 V DC/PROFIBUS PA
Power connection:
24 V DC or PROFIBUS PA bus
(not polarity sensitive).
Notes:
Refer to the instruction manual or contact a Siemens representative
for detailed wiring information.
*Magnet activated sensor Test
A magnet can be used to test the sensor without opening the lid of the
Pointek CLS200 Digital version. Bring the magnet close to the test
area indicated on the enclosure. The sensor test starts and finishes
automatically after 10 seconds.
Pointek CLS200 connections
Siemens FI 01 · 2015
4/43
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Standard
■ Overview
■ Configuration
Installation
4
Pointek CLS300 (standard version) is an inverse frequency shift
capacitance level and material detection switch with optional
rod/cable choices and configurable output. CLS300 is ideal for
detecting liquids, solids, slurries, foam, and interfaces in
demanding conditions where high pressure and temperatures
are present and has the ability to tune out build-up on the probe.
Keep unit out of path of falling material, or protect probe from
falling material.
■ Benefits
• Patented Active-Shield technology so measurement is
unaffected by material buildup or nozzle interference in active
shield section
• Performs in extremely abrasive conditions because of solid
rod construction
• Three LED indicators for adjustment control, output status and
power
• High-temperature version up to 400 °C (752 °F)
Build up of material in active shield area does not affect
switch operation.
■ Application
.5
0
)
(2
Siemens FI 01 · 2015
in
4/44
M
Pointek CLS300 standard version has three LED indicators with
basic relay and solid-state switch alarms.
The robust design of CLS300 makes it specifically applicable for
heavy solids applications where abrasive materials occur as in
the mining industry.
The fully potted electronics are unaffected by condensation,
dust or vibration.
Wetted parts are made of stainless steel with a PFA shield for
high chemical resistance, and of ceramic and stainless steel for
high temperature version. Materials with low or high dielectric
constants can be accurately detected. The unique Active Shield
suppresses interference from material buildup or long installation nozzles.
The unique modular design of the Pointek CLS300 provides a
wide range of configurations, process connections, extensions
and approvals to meet the temperature and pressure requirements of specific applications. The modular design makes
ordering easier and reduces stocking requirements. A wide
range of probe configurations are available, including rod and
cable versions.
• Key Applications: liquids, slurries, bulk solids, relatively high
pressure and temperature, hazardous areas, milling and
mining applications
Min.
50 (2)
Install probe at least 50 (2) from tank wall.
Note angle of repose and adjust accordingly.
Pointek CLS300 installation, dimensions in mm (inch)
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Standard
■ Technical specifications
Design
Mode of operation
Measuring principle
Inverse frequency shift capacitive
level detection
Material (enclosure)
Powder-coated aluminum with gasket
Degree of Protection
Standard: Type 4/NEMA 4/IP65
Optional: Type 4/NEMA 4/IP68
Change in picoFarad (pF)
Cable inlet
2 x M20x1.5 thread
(option: 2 x ½" NPT conduit entry
including 1 plugged entry)
Input
Measured variable
Output
Output signal
• Relay output
- Max. contact voltage
- Max. contact current
- Max. switching capacity
- Time delay (ON and/or OFF)
• Solid-state output
- Output
- Protection
- Max. switching voltage
1 SPDT Form C relay
• 30 V DC
• 250 V AC
• 5 A (DC)
• 8 A (AC)
• 150 W (DC)
• 2 000 VA (AC)
1 ... 60 s
Galvanically isolated
Against reversed polarity (bipolar)
• 30 V (DC)
• 30 V peak (AC)
82 mA
- Max. load current
- Voltage drop
< 1 V, typical at 50 mA
- Time delay (pre or post switching) 1 ... 60 s
Controls and displays
Displays
3 LEDs, for probe status,
output status and power supply
Potentiometers
2 potentiometers for time delay and
sensitivity
Switches
5 DIP switches for delay on/off,
fail-safe high/low, time delay
test/adjust, high/low sensitivity,
test delay settings
Power supply
Supply
Certificates and approvals
General Purpose
CSA, FM, CE, RCM
Flameproof Enclosure with IS Probe
ATEX II 1/2 G EEx d[ia] IIC T6...T1
ATEX II 1/2 D T100 °C
Dust Ignition Proof with IS Probe
ATEX II 1/2 D T100 °C
CSA/FM Class II, Div. 1,
Groups E, F, G
CSA/FM Class III T4
Explosion Proof Enclosure with
IS Probe
CSA/FM Class I, Div. 1,
Groups A, B, C, D
CSA/FM Class II, Div. 1,
Groups E, F, G
CSA/FM Class III T4
Marine
Lloyds Register of Shipping,
Categories ENV1, ENV2 and ENV5
Overfill Protection
WHG (Germany)
VLAREM II (Belgium)
Others
Pattern Approval (China)
Accuracy
Resolution
• Min. sensitivity (pF)
• Max. temperature error
1 % change in actual capacitance
0.2 % of actual capacitance value
Rated operating conditions1)
Installation conditions
• Location
Indoor/outdoor
Ambient conditions
• Ambient temperature
-40 ... +85 °C (-40 ... +185 °F)2)
Medium conditions
• Relative dielectric constant r
• Process temperature
- Rod/Cable version
- High-temperature version
• Process pressure3)
Liquids, bulk solids, slurries and
interfaces, and applications with
viscous materials
Min. 1.5
-40 ... +200 °C (-40 ... +392 °F)2)
-40 ... +400 °C (-40 ... +752 °F)
-1 ... +35 bar g
(-14.6 ... +511 psi g)
12 ... 250 V AC/DC, 0 ... 60 Hz,
galvanically isolated, 2 W
1)
When operation is in areas classified as hazardous, observe restrictions
according to relevant certificate.
See also Pressure/Temperature curves starting on page 4/58.
2)
Thermal isolator is used if process connection temperature exceeds 85 °C
(185 °F).
3)
Pressure rating of process seal is temperature dependent.
See Pressure/Temperature curves starting on page 4/58.
Design: Probe
Rod version
High Temperature version
Cable version
Length
Min. 250 mm (9.8 inch),
max. 1 000 mm (40 inch)
Min. 250 mm (9.8 inch),
max. 1 000 mm (40 inch)
Min. 1 000 mm (40 inch),
max. 25 000 mm (984 inch)
Sensor wetted parts
PFA (no insulation on active probe),
316L stainless steel, PEEK isolators
Ceramic (ZrO21)) isolators
(no insulation on active probe),
316L stainless steel
316 stainless steel, optional PFA,
PEEK isolators
O-ring seal material
FKM (optional FFKM)2)
Graphite2)
FKM (optional FFKM)2)
Thermal isolator
Optional
Standard
Optional
Extension
User selectable length
User selectable length
User selectable cable length
1)
Zirconium Oxide
2)
For Caustic Materials, please contact [email protected] for alternative O-Rings.
Siemens FI 01 · 2015
4/45
4
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Standard
Selection and Ordering data
Article No.
Selection and Ordering data
Article No.
Pointek CLS300 - Standard - Rod Version
with Threaded or Flanged process connection
Inverse frequency shift capacitance level and
material detection switch with optional rod/cable
choices and configurable output. CLS300 is ideal
for detecting liquids, solids, slurries, foam, and
interfaces in demanding conditions where high
pressure and temperatures are present, and has
the ability to tune out build-up on the probe.
7ML5650-
Pointek CLS300 - Standard - Rod Version
with Threaded or Flanged process connection
Inverse frequency shift capacitance level and
material detection switch with optional rod/cable
choices and configurable output. CLS300 is ideal
for detecting liquids, solids, slurries, foam, and
interfaces in demanding conditions where high
pressure and temperatures are present, and has
the ability to tune out build-up on the probe.
7ML5650-
77777 - 7777
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Add Order code Y01 and plain text:
"Insertion length ... mm"
Extended rod, factory adjusted length
250 ... 499 mm (9.8 ... 19.65 inch)
Extended rod, factory adjusted length
500 ... 749 mm (19.69 ... 29.49 inch)
Extended rod, factory adjusted length
750 ... 999 mm (29.53 ... 39.3 inch)
Process connection
Threaded, 316L stainless steel
4
¾" NPT [(Taper), ANSI/ASME B1.20.1]
1" NPT [(Taper), ANSI/ASME B1.20.1]
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
¢ 0A
¢ 0B
¢ 0C
1½" NPT [(Taper), ANSI/ASME B1.20.1]
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
¢ 0D
¢ 1A
¢ 1B
R 1½" [(BSPT), EN 10226/PT (JIS-T),
JIS B 0203]
¢ 1D
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
¢ 3A
¢ 3B
¢ 3D
Welded flange, 316L stainless steel, raised face
¢ 5A
5B
5C
1½" ASME, 150 lb
1½" ASME, 300 lb
1½" ASME, 600 lb
¢ 5D
5E
5F
2" ASME, 150 lb
2" ASME, 300 lb
2" ASME, 600 lb
¢ 5G
5H
5J
3" ASME, 150 lb
3" ASME, 300 lb
3" ASME, 600 lb
¢ 5K
5L
5M
4" ASME, 150 lb
4" ASME, 300 lb
4" ASME, 600 lb
¢ 5N
5P
5Q
Welded flange, 316L stainless steel,
Type A flat faced
DN 25, PN 16
DN 25, PN 40
DN 40, PN 16
¢ 6A
6B
¢ 6C
DN 40, PN 40
DN 50, PN 16
DN 50, PN 40
6D
¢ 6E
6F
DN 80, PN 16
DN 80, PN 40
DN 100, PN 16
¢ 6G
6H
¢ 6J
¢
F
¢
G
¢
¢
Wetted seals
FKM
FFKM [for process temperatures above
-20 °C (-4 °F)]
¢
¢
Probe material
316L stainless steel with PFA lining and PEEK
isolators
¢
0
1
0
1
0
¢
¢
¢
¢
Dust Ignition Proof with IS Probe:
CE, RCM, ATEX II 1/2 D T100 °C
¢
C
Flameproof Enclosure with IS Probe:
CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T1,
ATEX II 1/2 D T100 °C
Flameproof Enclosure with IS Probe,
with WHG approval:
CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T1,
ATEX II 1/2 D T100 °C
¢
D
¢
E
Dust Ignition Proof with IS Probe:
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
¢
F
Explosion Proof Enclosure with IS Probe:
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
¢
G
General Purpose (CSA, FM)
¢
H
General Purpose (CE, RCM)
¢
J
General Purpose with WHG approval
(CSA, FM, CE, RCM)
¢
K
Active shield length
Standard length (125 mm threaded, 105 mm flanged)
Extended shield (250 mm threaded, 230 mm flanged)1)
Extended shield (400 mm threaded, 380 mm flanged)2)
Probe length (length from flange face)
(threaded lengths include process thread)
Note: No Y01 needed in Order code for
standard lengths
Siemens FI 01 · 2015
E
Thermal isolator
Without thermal isolator
With thermal isolator [for process connection
temperatures over 85 °C (185 °F)]
Enclosure and lid
Aluminum epoxy coated
2 x ½" NPT via adapter - cable inlet, IP65
2 x M20x1.5 cable inlet, IP65
2 x ½" NPT via adapter - cable inlet, IP68
2 x M20x1.5 cable inlet, IP68
6K
DN 100, PN 40
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5 or EN 1092-1 standard.)
4/46
¢
Approvals
1" ASME, 150 lb
1" ASME, 300 lb
1" ASME, 600 lb
Standard version, rod 350 mm (13.78 inch)
Extended rod, length 500 mm (19.69 inch)
Extended rod, length 750 mm (29.53 inch)
Extended rod, length 1 000 mm (39.37 inch)
77777 - 7777
A
B
C
D
¢
¢
¢
¢
A
B
C
D
¢
0
¢
1
¢
2
1)
Available with Probe version options B ... D, F, G only
[ 500 mm (19.69 inch)]
2)
Available with Probe version options C, D, and, G only
[ 750 mm (29.53 inch)]
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Standard
Selection and Ordering data
Order code
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
Total insertion length: enter the total insertion length ¢ Y01
in plain text description
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Measuring-point number/identification
(max. 27 characters) specify in plain text
Manufacturer's test certificate: M to DIN 55350,
Part 18 and to ISO 9000
¢ C11
Inspection Certificate Type 3.1 per EN 10204
¢ C12
Operating Instructions
Note: The Operating Instructions should be
ordered as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
manual library.
See page 4/57
Accessories
See page 4/57
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Selection and Ordering data
Article No.
Pointek CLS300 - Standard - Cable Version
with Threaded or Flanged process connection
Inverse frequency shift capacitance level and
material detection switch with optional rod/cable
choices and configurable output. CLS300 is ideal
for detecting liquids, solids, slurries, foam, and
interfaces in demanding conditions where high
pressure and temperatures are present, and has
the ability to tune out build-up on the probe.
7ML56517 7 7 77 - 77 7 7
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Process connection
Threaded, 316L stainless steel
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
1½" NPT [(Taper), ANSI/ASME B1.20.1]
R 1½" [(BSPT), EN 10226/PT (JIS-T),
JIS B 0203]
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
¢ 0C
¢ 0D
¢ 1D
4
¢ 3D
Welded flange, 316L stainless steel, raised face
1½" ASME, 150 lb
1½" ASME, 300 lb
1½" ASME, 600 lb
¢ 5D
5E
5F
2" ASME, 150 lb
2" ASME, 300 lb
2" ASME, 600 lb
¢ 5G
5H
5J
3" ASME, 150 lb
3" ASME, 300 lb
3" ASME, 600 lb
¢ 5K
5L
5M
4" ASME, 150 lb
4" ASME, 300 lb
4" ASME, 600 lb
¢ 5N
5P
5Q
Welded flange, 316L stainless steel,
Type A flat faced
DN 40, PN 16
DN 40, PN 40
DN 50, PN 16
¢ 6C
6D
¢ 6E
DN 50, PN 40
DN 80, PN 16
DN 80, PN 40
6F
¢ 6G
6H
DN 100, PN 16
DN 100, PN 40
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5 or EN 1092-1 standard.)
¢ 6J
6K
Probe length (length from flange face)
(threaded lengths include process thread)
Note: No Y01 needed in Order code for
standard lengths
Extended cable, 3 000 mm (118.11 inch),
length can be shortened by customer
Extended cable, 6 000 mm (236.22 inch),
length can be shortened by customer
¢
A
¢
B
Extended cable, 500 ... 1 000 mm
(19.69 ... 39.37 inch)
¢
E
Extended cable, 1 001 ... 5 000 mm
(39.41 ... 196.85 inch)
¢
F
Extended cable, 5 001 ... 10 000 mm
(196.89 ... 393.70 inch)
¢
G
Extended cable, 10 001 ... 15 000 mm
(393.74 ... 590.55 inch)
Extended cable, 15 001 ... 20 000 mm
(590.59 ... 787.40 inch)
¢
H
¢
J
Extended cable, 20 001 ... 25 000 mm
(787.44 ... 984.25 inch)
¢
K
Add Order code Y01 and plain text:
"Insertion length ... mm"
Siemens FI 01 · 2015
4/47
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Standard
Selection and Ordering data
Article No.
Selection and Ordering data
Pointek CLS300 - Standard - Cable Version
with Threaded or Flanged process connection
Inverse frequency shift capacitance level and
material detection switch with optional rod/cable
choices and configurable output. CLS300 is ideal
for detecting liquids, solids, slurries, foam, and
interfaces in demanding conditions where high
pressure and temperatures are present, and has
the ability to tune out build-up on the probe.
7ML5651-
Further designs
77 7 77 - 77 77
Please add "-Z" to Article No. and specify Order
code(s).
Thermal isolator
Without thermal isolator
With thermal isolator [for process connection
temperatures over 85 °C (185 °F)]
4
Wetted seals
FKM
FFKM [for process temperatures above
-20 °C (-4 °F)]
Total insertion length: enter the total insertion length ¢ Y01
in plain text description
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Measuring-point number/identification
(max. 27 characters) specify in plain text
¢
¢
0
1
¢
¢
0
1
0
1
Dust Ignition Proof with IS Probe:
CE, RCM, ATEX II 1/2 D T100 °C
¢
C
Flameproof Enclosure with IS Probe:
CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T1,
ATEX II 1/2 D T100 °C
Flameproof Enclosure with IS Probe,
with WHG approval:
CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T1,
ATEX II 1/2 D T100 °C
¢
D
¢
E
Dust Ignition Proof with IS Probe:
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
¢
F
Explosion Proof Enclosure with IS Probe:
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
¢
G
General Purpose (CSA, FM)
¢
H
General Purpose (CE, RCM)
¢
J
General Purpose with WHG approval
(CSA, FM, CE, RCM)
¢
K
Enclosure and lid
Aluminum epoxy coated
1)
¢
¢
¢
¢
A
B
C
D
¢
0
¢
1
¢
2
Available with Probe version options A, B, F ... K, only
[ 1 000 mm (39.7 inch)]
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
4/48
Siemens FI 01 · 2015
¢ C11
Inspection Certificate Type 3.1 per EN 10204
¢ C12
Note: The Operating Instructions should be
ordered as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
manual library.
See page 4/57
Accessories
See page 4/57
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Approvals
Active shield length
Standard length (125 mm threaded, 105 mm flanged)
Extended shield (250 mm threaded, 230 mm flanged)1)
Extended shield (400 mm threaded, 380 mm flanged)1)
Manufacturer's test certificate: M to DIN 55350,
Part 18 and to ISO 9000
Operating Instructions
Probe material
Bare 316L stainless steel cable, PEEK isolators and ¢
316L stainless steel cable weight
PFA coated cable, PEEK isolators and 316L
¢
stainless steel cable weight
2 x ½" NPT via adapter - cable inlet, IP65
2 x M20x1.5 cable inlet, IP65
2 x ½" NPT via adapter - cable inlet, IP68
2 x M20x1.5 cable inlet, IP68
Order code
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Standard
Selection and Ordering data
Article No.
Selection and Ordering data
Article No.
Pointek CLS300 - Standard - High Temperature
Rod Version with Threaded or Flanged process
connection
Inverse frequency shift capacitance level and
material detection switch with optional rod/cable
choices and configurable output. CLS300 is ideal
for detecting liquids, solids, slurries, foam, and
interfaces in demanding conditions where high
pressure and temperatures are present, and has
the ability to tune out build-up on the probe.
7ML5652-
Pointek CLS300 - Standard - High Temperature
Rod Version with Threaded or Flanged process
connection
Inverse frequency shift capacitance level and
material detection switch with optional rod/cable
choices and configurable output. CLS300 is ideal
for detecting liquids, solids, slurries, foam, and
interfaces in demanding conditions where high
pressure and temperatures are present, and has
the ability to tune out build-up on the probe.
7ML5652-
7 7 7 00 7 - 7 7 7 7
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Add Order code Y01 and plain text:
"Insertion length ... mm"
Extended rod, factory adjusted length
250 ... 499 mm (9.8 ... 19.65 inch)
Extended rod, factory adjusted length
500 ... 749 mm (19.69 ... 29.49 inch)
Extended rod, factory adjusted length
750 ... 999 mm (29.53 ... 39.3 inch)
Process connection
Threaded, 316L stainless steel
¾" NPT [(Taper), ANSI/ASME B1.20.1]
1" NPT [(Taper), ANSI/ASME B1.20.1]
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
¢ 0A
¢ 0B
¢ 0C
1½" NPT [(Taper), ANSI/ASME B1.20.1]
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
¢ 0D
¢ 1A
¢ 1B
R 1½" [(BSPT), EN 10226/PT (JIS-T),
JIS B 0203]
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
¢ 3D
¢
E
¢
F
¢
G
4
Wetted seals
Graphite
¢
¢ 1D
Probe material
316L stainless steel with ceramic (ZrO2) isolators
¢
¢ 3A
Approvals
¢ 3B
Dust Ignition Proof with IS Probe:
CE, RCM, ATEX II 1/2 D T100 °C
¢
C
Flameproof Enclosure with IS Probe:
CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T1,
ATEXII 1/2 D T100 °C
Flameproof Enclosure with IS Probe,
with WHG approval:
CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T1,
ATEX II 1/2 D T100 °C
¢
D
¢
E
Dust Ignition Proof with IS Probe:
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
¢
F
Explosion Proof Enclosure with IS Probe:
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
¢
G
General Purpose (CSA, FM)
¢
H
General Purpose (CE, RCM)
¢
J
General Purpose with WHG approval
(CSA, FM, CE, RCM)
¢
K
Welded flange, 316L stainless steel, raised face
1" ASME, 150 lb
1" ASME, 300 lb
1" ASME, 600 lb
¢ 5A
5B
5C
1½" ASME, 150 lb
1½" ASME, 300 lb
1½" ASME, 600 lb
¢ 5D
5E
5F
2" ASME, 150 lb
2" ASME, 300 lb
2" ASME, 600 lb
¢ 5G
5H
5J
3" ASME, 150 lb
3" ASME, 300 lb
3" ASME, 600 lb
¢ 5K
5L
5M
4" ASME, 150 lb
4" ASME, 300 lb
4" ASME, 600 lb
¢ 5N
5P
5Q
Welded flange, 316L stainless steel,
Type A flat faced
DN 25, PN 16
DN 25, PN 40
DN 40, PN 16
¢ 6A
6B
¢ 6C
DN 40, PN 40
DN 50, PN 16
DN 50, PN 40
6D
¢ 6E
6F
DN 80, PN 16
DN 80, PN 40
DN 100, PN 16
¢ 6G
6H
¢ 6J
0
0
Enclosure and lid
Aluminum epoxy coated
2 x ½" NPT via adapter - cable inlet, IP65
2 x M20x1.5 cable inlet, IP65
2 x ½" NPT via adapter - cable inlet, IP68
¢
¢
¢
A
B
C
2 x M20x1.5 cable inlet, IP68
¢
D
Active shield length
Standard length (125 mm threaded, 105 mm flanged)
Extended shield (250 mm threaded, 230 mm flanged)1)
Extended shield (400 mm threaded, 380 mm flanged)2)
6K
DN 100, PN 40
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5 or EN 1092-1 standard.)
¢
0
¢
1
¢
2
1)
Available with Probe version options B ... D, F, G only
[ 500 mm (19.69 inch)]
2)
Available with Probe version options C, D, and, G only
[ 750 mm (29.53 inch)]
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Probe length (length from flange face)
(threaded lengths include process thread)
Note: No Y01 needed in Order code for
standard lengths
Standard version rod 350 mm (13.78 inch)
Extended rod, length 500 mm (19.69 inch)
Extended rod, length 750 mm (29.53 inch)
Extended rod, length 1 000 mm (39.37 inch)
7 7 7 00 7 - 7 7 7 7
¢
¢
¢
¢
A
B
C
D
Siemens FI 01 · 2015
4/49
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Standard
Selection and Ordering data
Order code
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
Total insertion length: enter the total insertion length ¢ Y01
in plain text description
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Measuring-point number/identification
(max. 27 characters) specify in plain text
Manufacturer's test certificate: M to DIN 55350,
Part 18 and to ISO 9000
¢ C11
Inspection Certificate Type 3.1 per EN 10204
¢ C12
Operating Instructions
4
Note: The Operating Instructions should be
ordered as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
manual library.
See page 4/57
Accessories
See page 4/57
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
4/50
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Digital
■ Overview
The unique modular design of the Pointek CLS300 provides a
wide range of configurations, process connections, extensions
and approvals to meet the temperature and pressure requirements of specific applications. The modular design makes
ordering easier and reduces stocking requirements. A wide
range of probe configurations are available, including rod and
cable versions.
• Key Applications: liquids, slurries, bulk solids, relatively high
pressure and temperature, hazardous areas, milling and
mining applications
■ Configuration
Installation
4
Pointek CLS300 (digital version) is an inverse frequency shift
capacitance level and material detection switch with optional
rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding
conditions where high pressure and temperatures are present
and has the ability to tune out build-up on the probe. The digital
version includes PROFIBUS PA, an LCD display, and advanced
diagnostic features.
■ Benefits
• Patented Active-Shield technology so measurement is
unaffected by material buildup or nozzle interference in active
shield section
• Performs in extremely abrasive conditions because of solid
rod construction
• Push-button calibration, full-function diagnostics
• High sensitivity allows installation in a wide range of liquids,
solids or slurry applications
• Integral LCD display allows for easy menu-driven setup
• PROFIBUS PA communication (SIMATIC PDM compatible)
■ Application
Keep unit out of path of falling material, or protect probe from
falling material.
Build up of material in active shield area does not affect
switch operation.
Pointek CLS300 digital version provides an integral LCD display
for stand-alone use, with PROFIBUS PA communication
(Profile version 3.0, Class B) when required. Solid-state switch
alarm is standard.
The robust design of CLS300 makes it specifically applicable for
heavy solids applications where abrasive materials occur as in
the mining industry.
M
The fully potted electronics are unaffected by condensation,
dust or vibration.
in
.5
0
Wetted parts are made of stainless steel with a PFA shield for
high chemical resistance, and of ceramic and stainless steel for
high temperature version. Materials with low or high dielectric
constants can be accurately detected. The unique Active Shield
suppresses interference from material buildup or long installation nozzles.
)
(2
Min.
50 (2)
Install probe at least 50 (2) from tank wall.
Note angle of repose and adjust accordingly.
Pointek CLS300 installation, dimensions in mm (inch)
Siemens FI 01 · 2015
4/51
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Digital
■ Technical specifications
Mode of operation
Measuring principle
Inverse frequency shift capacitive
level detection
Controls and displays
Local display
Configuration
Input
Measured variable
Change in picoFarad (pF)
Power supply
Bus voltage (at process connection)
Output
Solid-state output
• Output
• Protection
• Max. switching voltage
4
• Max. load current
• Voltage drop
• Time delay (pre or post switching)
Fail-safe mode
Connection
Galvanically isolated
Against reversed polarity (bipolar)
• 30 V (DC)
• 30 V peak (AC)
82 mA
< 1 V, typical at 50 mA
Programmable by user (0 ... 100 s)
Min. or max.
Removable terminal block
Current consumption
Certificates and approvals
General Purpose
Dust Ignition Proof
Flameproof Enclosure With IS Probe
Dust Ignition Proof With IS Probe
Intrinsically Safe4)
Accuracy
Resolution
• Min. sensitivity (pF)
• Max. temperature error
1 % change in actual capacitance
0.2 % of actual capacitance value
Rated operating conditions1)
Installation conditions
Non-incendive
Location
Indoor/outdoor
Ambient conditions
• Ambient temperature
-40 ... +85 °C (-40 ... +185 °F)2)
Medium conditions
• Relative dielectric constant r
• Process temperature
- Rod/Cable version
- High Temperature version
• Process pressure3)
Design
Material (enclosure)
Degree of protection
Cable inlet
Liquids, bulk solids, slurries and
interfaces, and applications with
viscous materials
Min. 1.5
Explosion Proof with IS Probe
Marine
-40 ... +200 °C (-40 ... +392 °F)2)
-40 ... +400 °C (-40 ... +752 °F)
-1 ... +35 bar g (-14.6 ... +511 psi g)
Others
Communication
LCD
• Locally, using 3 button keypad
(for standalone operation)
• Remotely, using SIMATIC PDM
(for installation on a network)
• Standard: 12 ... 30 V DC
• Intrinsically Safe: 12 ... 24 V DC
12.5 mA
CSA, FM, CE, RCM
ATEX II 1/2 D, 2 D IP6X T100 °C
ATEX II 1/2 G EEx d[ia] IIC T6...T4
ATEX II 1/2 D T100 °C
CSA/FM Class II, Div. 1,
Groups E, F, G
CSA/FM Class III T4
ATEX II 1 G EEx ia IIC T6...T4
ATEX II 1/2 D, 2 D IP6X T100 °C
CSA/FM Class I, Div. 1,
Groups A, B, C, D
CSA/FM Class II, Div. 1,
Groups E, F, G
CSA/FM Class III T4
CSA/FM Class I, Div. 2,
Groups A, B, C, D
CSA/FM Class II, Div. 2,
Groups F, G
CSA/FM Class III T4 or T6
CSA/FM Class I, Div. 1,
Groups A, B, C, D
CSA/FM Class II, Div. 1,
Groups E, F, G
CSA/FM Class III T4
Lloyds Register of Shipping,
Categories ENV1, ENV2 and ENV5
Pattern Approval (China)
PROFIBUS PA
(IEC 61158 CPF3 CP3/2)
Bus physical layer:
IEC 61158-2 MBP-(IS)
Powder-coated aluminum with gasket
Standard: Type 4/NEMA 4/IP65
Optional: Type 4/NEMA 4/IP68
2 x M20x1.5 thread
(option: 2 x ½" NPT conduit entry
including 1 plugged entry)
Device profile: PROFIBUS PA profile
for Process Control Devices Version
3.0, Class B
FISCO field device
1)
When operation is in areas classified as hazardous, observe restrictions
according to relevant certificate.
See also Pressure/Temperature curves starting on page 4/58.
2)
Thermal isolator is used if process connection temperature exceeds 85 °C
(185 °F)
3)
Pressure rating of process seal is temperature dependent.
See Pressure/Temperature curves starting on page 4/58.
4)
Barrier or Intrinsically Safe power supply required for Intrinsically Safe
protection
Design: Probe
Rod version
High Temperature version
Cable version
Length
Min. 250 mm (9.8 inch),
max. 1 000 mm (40 inch)
Min. 250 mm (9.8 inch),
max. 1 000 mm (40 inch)
Min. 1 000 mm (40 inch),
max. 25 000 mm (984 inch)
Sensor wetted parts
PFA (no insulation on active probe),
316L stainless steel, PEEK isolators
Ceramic (ZrO21)) isolators
(no insulation on active probe),
316L stainless steel
316 stainless steel, optional PFA,
PEEK isolators
O-ring seal material
FKM (optional FFKM)2)
Graphite2)
FKM (optional FFKM)2)
Thermal isolator
Optional
Standard
Optional
Extension
User selectable length
User selectable length
User selectable cable length
1)
Zirconium Oxide
2)
For Caustic Materials, please contact [email protected] for alternative O-Rings
4/52
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Digital
Selection and Ordering data
Article No.
Selection and Ordering data
Article No.
Pointek CLS300 - Digital - Rod with
Threaded or Flanged process connection
Inverse frequency shift capacitance level and
material detection switch with optional rod/cable
choices and configurable output. It is ideal for
detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present and has the
ability to tune out build-up on the probe.
7ML5660-
Pointek CLS300 - Digital - Rod with
Threaded or Flanged process connection
Inverse frequency shift capacitance level and
material detection switch with optional rod/cable
choices and configurable output. It is ideal for
detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present and has the
ability to tune out build-up on the probe.
7ML5660-
77 7 77 - 77 77
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
7 7 7 77 - 77 7 7
Add Order code Y01 and plain text:
"Insertion length ... mm"
Extended rod, factory adjusted length
250 ... 499 mm (9.8 ... 19.65 inch)
Extended rod, factory adjusted length
500 ... 749 mm (19.69 ... 29.49 inch)
Extended rod, factory adjusted length
750 ... 999 mm (29.53 ... 39.3 inch)
Process connection
Threaded, 316L stainless steel
¾" NPT [(Taper), ANSI/ASME B1.20.1]
1" NPT [(Taper), ANSI/ASME B1.20.1]
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
¢ 0A
¢ 0B
¢ 0C
1½" NPT [(Taper), ANSI/ASME B1.20.1]
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
¢ 0D
¢ 1A
¢ 1B
R 1½" [(BSPT), EN 10226/PT (JIS-T),
JIS B 0203]
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
¢ 1D
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
¢ 3D
Thermal isolator
Without thermal isolator
With thermal isolator [for process connection
temperatures over 85 °C (185 °F)]
¢
E
¢
F
¢
G
¢
0
¢
1
Wetted seals
FKM
¢
FFKM [for process temperatures above -20 °C (-4 °F)]¢
¢ 3A
¢ 3B
Probe material
316L stainless steel with PFA lining and PEEK
isolators
Welded flange, 316L stainless steel, raised face
¢
4
0
1
0
Approvals
1" ASME, 150 lb
1" ASME, 300 lb
1" ASME, 600 lb
¢ 5A
5B
5C
1½" ASME, 150 lb
1½" ASME, 300 lb
1½" ASME, 600 lb
¢ 5D
5E
5F
2" ASME, 150 lb
2" ASME, 300 lb
¢ 5G
5H
2" ASME, 600 lb
5J
3" ASME, 150 lb
3" ASME, 300 lb
3" ASME, 600 lb
¢ 5K
5L
5M
4" ASME, 150 lb
4" ASME, 300 lb
4" ASME, 600 lb
¢ 5N
5P
5Q
Welded flange, 316L stainless steel,
Type A flat faced
DN 25, PN 16
DN 25, PN 40
DN 40, PN 16
¢ 6A
6B
¢ 6C
DN 40, PN 40
DN 50, PN 16
DN 50, PN 40
6D
¢ 6E
6F
DN 80, PN 16
DN 80, PN 40
DN 100, PN 16
¢ 6G
6H
¢ 6J
Dust Ignition Proof:
CE, RCM, ATEX II 1/2 D, 2 D IP6X T100 °C
¢
B
Intrinsically Safe1)
CE, RCM, ATEX II 1 G EEx ia IIC T6...T4,
ATEX II 1/2 D, 2 D IP6X T100 °C
¢
C
Flameproof Enclosure with IS Probe:
CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T4,
ATEX II 1/2 D T100 °C
¢
D
Dust Ignition Proof with IS Probe:
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
¢
E
Intrinsically Safe1)
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
¢
F
Explosion Proof Enclosure with IS Probe:
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
¢
G
General Purpose (CSA, FM)
¢
H
General Purpose (CSA, FM, CE, RCM)
¢
J
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
6K
DN 100, PN 40
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5 or EN 1092-1 standard.)
Probe length (length from flange face)
(threaded lengths include process thread)
Note: No Y01 needed in Order code for
standard lengths
Standard version, rod 350 mm (13.78 inch)
Extended rod, length 500 mm (19.69 inch)
Extended rod, length 750 mm (29.53 inch)
Extended rod, length 1 000 mm (39.37 inch)
¢
¢
¢
¢
A
B
C
D
Siemens FI 01 · 2015
4/53
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Digital
Selection and Ordering data
Article No.
Selection and Ordering data
Article No.
Pointek CLS300 - Digital - Rod with
Threaded or Flanged process connection
Inverse frequency shift capacitance level and
material detection switch with optional rod/cable
choices and configurable output. It is ideal for
detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present and has the
ability to tune out build-up on the probe.
7ML5660-
Pointek CLS300 - Digital - Cable with
Threaded or Flanged process connection
Inverse frequency shift capacitance level and
material detection switch with optional rod/cable
choices and configurable output. It is ideal for
detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present and has the
ability to tune out build-up on the probe.
7ML5661-
77 7 77 - 77 77
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Enclosure and Lid
Aluminum epoxy coated
2 x ½" NPT via adapter - cable inlet, IP65
2 x M20x1.5 cable inlet, IP65
2 x ½" NPT via adapter - cable inlet, IP68
2 x M20x1.5 cable inlet, IP68
4
Active shield length
Standard length (125 mm threaded, 105 mm flanged)
Extended shield (250 mm threaded, 230 mm flanged)2)
Extended shield (400 mm threaded, 380 mm flanged)3)
¢
¢
¢
¢
Process connection
Threaded, 316L stainless steel
A
B
C
D
¢
0
¢
1
¢
2
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
¢
1½" NPT [(Taper), ANSI/ASME B1.20.1]
¢
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] ¢
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] ¢
Barrier or Intrinsically Safe power supply required for Intrinsically Safe
protection
2)
Available with Probe version options B ... D, F, G only
[ 500 mm (19.69 inch)]
3)
Available with Probe version options C, D, and, G only
[ 750 mm (29.53 inch)]
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Order code
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
Total insertion length: enter the total insertion length ¢ Y01
in plain text description
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Measuring-point number/identification
(max. 27 characters) specify in plain text
Manufacturer's test certificate: M to DIN 55350,
Part 18 and to ISO 9000
¢ C11
Inspection Certificate Type 3.1 per EN 10204
¢ C12
Operating Instructions
Note: The Operating Instructions should be
ordered as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
manual library.
See page 4/57
Accessories
See page 4/57
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
1½" ASME, 150 lb
1½" ASME, 300 lb
1½" ASME, 600 lb
¢ 5D
5E
5F
2" ASME, 150 lb
2" ASME, 300 lb
2" ASME, 600 lb
¢ 5G
5H
5J
3" ASME, 150 lb
3" ASME, 300 lb
3" ASME, 600 lb
¢ 5K
5L
5M
4" ASME, 150 lb
4" ASME, 300 lb
4" ASME, 600 lb
¢ 5N
5P
5Q
Welded flange, 316L stainless steel,
Type A flat faced
DN 40, PN 16
DN 40, PN 40
DN 50, PN 16
¢ 6C
6D
¢ 6E
DN 50, PN 40
DN 80, PN 16
DN 80, PN 40
6F
¢ 6G
6H
DN 100, PN 16
DN 100, PN 40
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5 or EN 1092-1 standard.)
¢ 6J
6K
Probe length (length from flange face)
(threaded lengths include process thread)
Note: No Y01 needed in Order code for
standard lengths
Extended cable, 3 000 mm (118.11 inch),
length can be shortened by customer
Extended cable, 6 000 mm (236.22 inch),
length can be shortened by customer
Add Order code Y01 and plain text:
"Insertion length ... mm"
Extended cable, 500 ... 1 000 mm
(19.69 ... 39.37 inch)
Extended cable, 1 001 ... 5 000 mm
(39.41 ... 196.85 inch)
Extended cable, 5 001 ... 10 000 mm
(196.89 ... 393.70 inch)
Extended cable, 10 001 ... 15 000 mm
(393.74 ... 590.55 inch)
Extended cable, 15 001 ... 20 000 mm
(590.59 ... 787.40 inch)
Extended cable, 20 001 ... 25 000 mm
(787.44 ... 984.25 inch)
4/54
Siemens FI 01 · 2015
0C
0D
1D
3D
Welded flange, 316L stainless steel, raised face
1)
Selection and Ordering data
7 7 7 77 - 77 7 7
¢
A
¢
B
¢
E
¢
F
¢
G
¢
H
¢
J
¢
K
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Digital
Order code
Selection and Ordering data
Article No.
Selection and Ordering data
Pointek CLS300 - Digital - Cable with
Threaded or Flanged process connection
Inverse frequency shift capacitance level and
material detection switch with optional rod/cable
choices and configurable output. It is ideal for
detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present and has the
ability to tune out build-up on the probe.
7ML5661-
Further designs
77 7 77 - 77 77
Please add "-Z" to Article No. and specify Order
code(s).
Thermal isolator
Without thermal isolator
With thermal isolator [for process connection
temperatures over 85 °C (185 °F)]
Total insertion length: enter the total insertion length ¢ Y01
in plain text description
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Measuring-point number/identification
(max. 27 characters) specify in plain text
¢
¢
Wetted seals
FKM
¢
FFKM [for process temperatures above -20 °C (-4 °F)]¢
Probe material
Bare 316L stainless steel cable, PEEK isolators and ¢
316L stainless steel cable weight
PFA coated cable, PEEK isolators and 316L
¢
stainless steel cable weight
0
1
Manufacturer's test certificate: M to DIN 55350,
Part 18 and to ISO 9000
¢ C11
Inspection Certificate Type 3.1 per EN 10204
¢ C12
Operating Instructions
0
1
See page 4/57
0
Note: The Operating Instructions should be
ordered as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
manual library.
1
Accessories
See page 4/57
4
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Approvals
Dust Ignition Proof:
CE, RCM, ATEX II 1/2 D, 2 D IP6X T100 °C
¢
B
Intrinsically Safe1)
CE, RCM, ATEX II 1 G EEx ia IIC T6 ... T4,
ATEX II 1/2 D, 2 D IP6X T100 °C
¢
C
Flameproof Enclosure with IS Probe:
CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6 ... T4,
ATEX II 1/2 D T100 °C
¢
D
Intrinsically Safe1)
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
¢
F
Explosion Proof Enclosure with IS Probe:
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
¢
G
General Purpose (CSA, FM)
¢
H
General Purpose (CSA, FM, CE, RCM)
¢
J
Enclosure and Lid
Aluminum epoxy coated
2 x ½" NPT via adapter - cable inlet, IP65
2 x M20x1.5 cable inlet, IP65
2 x ½" NPT via adapter - cable inlet, IP68
2 x M20x1.5 cable inlet, IP68
Active shield length
Standard length (125 mm threaded, 105 mm flanged)
Extended shield 250 mm threaded, 230 mm flanged)2)
Extended shield (400 mm threaded, 380 mm flanged)2)
¢
¢
¢
¢
A
B
C
D
¢
0
¢
1
¢
2
1)
Barrier or Intrinsically Safe power supply required for Intrinsically Safe
protection
2)
Available with Probe version options A, B and, F ... K only
[ 1 000 mm (39.7 inch)]
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Siemens FI 01 · 2015
4/55
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Digital
Selection and Ordering data
Article No.
Selection and Ordering data
Article No.
Pointek CLS300 - Digital - High Temperature
Rod version with Threaded or Flanged process
connection
Inverse frequency shift capacitance level and
material detection switch with optional rod/cable
choices and configurable output. It is ideal for
detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present and has the
ability to tune out build-up on the probe.
7ML5662-
Pointek CLS300 - Digital - High Temperature
Rod version with Threaded or Flanged process
connection
Inverse frequency shift capacitance level and
material detection switch with optional rod/cable
choices and configurable output. It is ideal for
detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present and has the
ability to tune out build-up on the probe.
7ML5662-
77 7 0 7 - 77 77
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Add Order code Y01 and plain text:
"Insertion length ... mm"
Extended rod, factory adjusted length
250 ... 499 mm (9.8 ... 19.65 inch)
Extended rod, factory adjusted length
500 ... 749 mm (19.69 ... 29.49 inch)
Process connection
Threaded, 316L stainless steel
4
¾" NPT [(Taper), ANSI/ASME B1.20.1]
1" NPT [(Taper), ANSI/ASME B1.20.1]
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
¢ 0A
¢ 0B
¢ 0C
1½" NPT [(Taper), ANSI/ASME B1.20.1]
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
¢ 0D
¢ 1A
¢ 1B
R 1½" [(BSPT), EN 10226/PT (JIS-T),
JIS B 0203]
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
¢ 1D
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
Extended rod, factory adjusted length
750 ... 999 mm (29.53 ... 39.3 inch)
3A
¢ 3D
Welded flange, 316L stainless steel, raised face
1" ASME, 150 lb
1" ASME, 300 lb
1" ASME, 600 lb
¢ 5A
5B
5C
1½" ASME, 150 lb
1½" ASME, 300 lb
1½" ASME, 600 lb
¢ 5D
5E
5F
2" ASME, 150 lb
2" ASME, 300 lb
2" ASME, 600 lb
¢ 5G
5H
5J
3" ASME, 150 lb
3" ASME, 300 lb
3" ASME, 600 lb
¢ 5K
5L
5M
4" ASME, 150 lb
4" ASME, 300 lb
4" ASME, 600 lb
¢ 5N
5P
5Q
Welded flange, 316L stainless steel,
Type A flat faced
DN 25, PN 16
DN 25, PN 40
DN 40, PN 16
¢ 6A
6B
¢ 6C
DN 40, PN 40
DN 50, PN 16
DN 50, PN 40
6D
¢ 6E
6F
DN 80, PN 16
DN 80, PN 40
DN 100, PN 16
DN 100, PN 40
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5 or EN 1092-1 standard.)
¢ 6G
6H
¢ 6J
6K
4/56
Siemens FI 01 · 2015
E
¢
F
¢
G
¢
Probe material
316L stainless steel with ceramic (ZrO2) isolators
¢
0
0
¢
B
¢
C
¢
D
¢
F
¢
G
¢
¢
H
J
Enclosure and Lid
Aluminum epoxy coated
2 x ½" NPT via adapter - cable inlet, IP65
2 x M20x1.5 cable inlet, IP65
2 x ½" NPT via adapter - cable inlet, IP68
2 x M20x1.5 cable inlet, IP68
Active shield length
Standard length - (125 mm threaded, 105 mm flanged)
Extended shield (250 mm threaded, 230 mm flanged)2)
Extended shield (400 mm threaded, 380 mm flanged)3)
¢
¢
¢
¢
A
B
C
D
¢
0
¢
1
¢
2
1)
Barrier or Intrinsically Safe power supply required for Intrinsically Safe
protection
2)
Available with Probe version options B ... D, F, G only
[ 500 mm (19.69 inch)]
3)
Available with Probe version options C, D, and, G only
[ 750 mm (29.53 inch)]
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Probe length (length from flange face)
(threaded lengths include process thread)
Note: No Y01 needed in Order code for
standard lengths
Standard version, rod 350 mm (13.78 inch)
Extended rod, length 500 mm (19.69 inch)
Extended rod, length 750 mm (29.53 inch)
Extended rod, length 1 000 mm (39.37 inch)
¢
Wetted seals
Graphite
Approvals
Dust Ignition Proof:
CE, RCM, ATEX II 1/2 D, 2 D IP6X T100 °C
Intrinsically Safe1)
CE, RCM, ATEX II 1 G EEx ia IIC T6...T4,
ATEX II 1/2 D, 2 D IP6X T100 °C
Flameproof Enclosure with IS Probe:
CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T4,
ATEX II 1/2 D T100 °C
Intrinsically Safe1)
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
Explosion Proof Enclosure with IS Probe:
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
General Purpose (CSA, FM)
General Purpose (CSA, FM, CE, RCM)
¢ 3B
7 7 7 0 7 - 77 7 7
¢
¢
¢
¢
A
B
C
D
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Standard and Digital
Selection and Ordering data
Order code
Article No.
Selection and Ordering data
Further designs
Operating Instructions - Standard
Please add "-Z" to Article No. and specify Order
code(s).
English
7ML1998-5JH04
German
Note: The Operating Instructions should be
ordered as a separate line on the order.
7ML1998-5JH34
Quick Start manual, multi-language
A5E32221251
Total insertion length: enter the total insertion length ¢ Y01
in plain text description
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Measuring-point number/identification
(max. 27 characters) specify in plain text
Manufacturer's test certificate: M to DIN 55350,
Part 18 and to ISO 9000
¢ C11
Inspection Certificate Type 3.1 per EN 10204
¢ C12
Operating Instructions
Note: The Operating Instructions should be
ordered as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
manual library.
See page 4/57
Accessories
See page 4/57
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
Operating Instructions - Digital
English
7ML1998-5JJ05
French
7ML1998-5JJ11
German
Note: The Operating Instructions should be
ordered as a separate line on the order.
7ML1998-5JJ34
Quick Start manual, multi-language
A5E32221496
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
Accessories
One metallic cable gland M20x1.5, -40 ... +80 °C
(-40 ... +176 °F) with integrated shield connection
(available for PROFIBUS PA)
7ML1930-1AQ
General Purpose
1/2" NPT General Purpose Cable Entry IP68/IP69K
NEMA6, -40 ... -100 °C (-40 ... -212 °F), cable size
6 ... 12 mm (0.236 ... 0.472 inch)
7ML1830-1JA
M20x1.5 General Purpose Cable Entry IP68/IP69K
NEMA6, -40 ... -100 °C (-40 ... -212 °F), cable size
7 ... 12 mm (0.275 ... 0.472 inch)
7ML1830-1JC
Hazardous Locations
1/2" NPT EMC rated Cable Gland: Dust Ignition Proof,
Flameproof Exd, and Increased Safety ATEX II 2 GD
ExtD A21 (Zone 1, Zone 2, Zone 21, Zone 22, and in
Gas Groups IIA,IIB and IIC) -60 ... +80 °C IP66, IP67,
IP68, NEMA4X, cable sizes 5.5 ... 12 mm
(0.216 ... 0.472 inch)
7ML1830-1JB
M20 EMC rated Cable Gland: Dust Ignition Proof,
Flameproof Exd, and Increased Safety ATEX II 2 GD
ExtD A21 (Zone 1, Zone 2, Zone 21, Zone 22 and in
Gas Groups IIA,IIB and IIC) -60 ... +80 °C IP66, IP67,
IP68, NEMA4X, cable sizes 5.5 ... 12 mm
(0.216 ... 0.472 inch)
7ML1830-1JD
Blind threaded flanges are available.
Please contact [email protected] with a
completed application data sheet on page 4/11
Pointek Specials
See page 4/80
Siemens FI 01 · 2015
4/57
4
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Standard and Digital
■ Characteristic curves
Pressure/temperature curve
CLS300 extended rod and cable probes
Threaded process connections
(7ML5650, 7ML5651, 7ML5660 and 7ML5661)
Permitted operating pressures P
40 bar (580 psi)
30 bar (435 psi)
20 bar (290 psi)
4
10 bar (145 psi)
Atmospheric
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
-29 ºC
(-20 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted operating temperature T
Example:
Permitted operating pressure = 30 bar (435 psi) at 75 °C
Pointek CLS300 Process Pressure/Temperature derating curves (7ML5650, 7ML5651, 7ML5660 and 7ML5661)
Pressure/temperature curve
CLS300 high temperature rod probes
Threaded process connections
(7ML5652 and 7ML5662)
Permitted operating pressures P
40 bar (580 psi)
30 bar (435 psi)
20 bar (290 psi)
10 bar (145 psi)
Atmospheric
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
-29 ºC
(-20 ºF)
Pointek CLS300 Process Pressure/Temperature derating curves (7ML5652 and 7ML5662)
4/58
Siemens FI 01 · 2015
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted operating temperature T
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Standard and Digital
Pressure/temperature curve
CLS300 extended rod and cable probes
ASME flanged process connections
(7ML5650, 7ML5651, 7ML5660 and 7ML5661)
Permitted operating pressures P
50 bar (725 psi)
40 bar (580 psi)
30 bar (435 psi)
ASME 300 lb1)
4
20 bar (290 psi)
Atmospheric
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
ASME 150 lb1)
10 bar (145 psi)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
-29 ºC
(-20 ºF)
1)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted operating temperature T
The curve denotes the minimum allowable flange class for the shaded area below.
Pointek CLS300 Process Pressure/Temperature derating curves (7ML5650, 7ML5651, 7ML5660, and 7ML5661)
Permitted operating pressures P
Pressure/temperature curve
CLS300 high temperature rod probes
ASME flanged process connections
(7ML5652 and 7ML5662)
90 bar (1.305 psi)
80 bar (1.160 psi)
70 bar (1.015 psi)
60 bar (870 psi)
ASME 600 lb1)
50 bar (725 psi)
40 bar (580 psi)
30 bar (435 psi)
ASME 300 lb1)
20 bar (290 psi)
ASME 150 lb1)
Atmospheric
10 bar (145 psi)
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
-29 ºC
(-20 ºF)
1)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted operating temperature T
The curve denotes the minimum allowable flange class for the shaded area below.
Pointek CLS300 Process Pressure/Temperature derating curves (7ML5652 and 7ML5662)
Siemens FI 01 · 2015
4/59
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Standard and Digital
Pressure/temperature curve
CLS300 extended rod and cable probes
EN flanged process connections
(7ML5650, 7ML5651, 7ML5660 and 7ML5661)
Permitted operating pressures P
50 bar (725 psi)
40 bar (580 psi)
30 bar (435 psi)
PN 401)
4
20 bar (290 psi)
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
PN 161)
10 bar (145 psi)
Atmospheric
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
300 ºC
(572 ºF)
-29 ºC
(-20 ºF)
1)
600 ºF
(315 ºC)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted operating temperature T
The curve denotes the minimum allowable flange class for the shaded area below.
Pointek CLS300 Process Pressure/Temperature derating curves (7ML5650, 7ML5651, 7ML5660 and 7ML5661)
Pressure/Temperature Curve
CLS300 High Temperature Rod Probes
EN Flanged Process Connections (7ML5652 and 7ML5662)
Permitted Operating Pressures P
50 bar (725 psi)
40 bar (580 psi)
30 bar (435 psi)
PN 401)
20 bar (290 psi)
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
PN 161)
10 bar (145 psi)
Atmospheric
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
-29 ºC
(-20 ºF)
1)
The curve denotes the minimum allowable flange class for the shaded area below.
Pointek CLS300 Process Pressure/Temperature derating curves (7ML5652 and 7ML5662)
4/60
Siemens FI 01 · 2015
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted Operating Temperature T
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Standard and Digital
■ Dimensional drawings
Rod version
Threaded (7ML5650 and 7ML5660)
Lid
Thermal
isolator
165 (6.50)
290 (11.42)
150
(5.91)
Thermal
isolator
Y02 1)
Ø10 (0.35)
Stainless
steel weight
Y01 (insertion length)
min. = 500 (20)/max. = 25 000 (984)
PFA insulated
cable
250 (9.84)
Y02
Y01 (insertion length)
min. = 500 (20)/max. = 25 000 (984)
Measuring length
250 (9.84)
Ø6 (0.24)
Y02 1)
Cable version, insulated
Threaded (7ML5651 and 7ML5661)
1)
Stainless
steel cable
Ø32 (1.26)
4
Lid without window
Ø19 (0.75)
Cable version, non-insulated
Threaded (7ML5651 and 7ML5661)
Stainless
steel weight
Y01 (insertion length)
min. = 250 (9.8)/max. = 1 000 (39.37)
Probe
Lid with window
Measuring length
Ø19 (0.75)
Ceramic
isolator(s)
M20: 135 (5.32)
½" NPT: 150 (5.91)
Measuring length
Y01 (insertion length)
min. = 250 (9.8)/max. = 1 000 (39.37)
Y02 1)
Measuring length
Probe
2 cable entries
½" NPT or
M20 x 1.5
20 (0.79)
275 (10.83)
Lid clip
Electronics/
enclosure
High temperature rod version
Threaded (7ML5652 and 7ML5662)
Ø32 (1.26)
Note:
1)
Extended Active Shield (Y02): standard length 125 (4.92). Optional active shield lengths: 250 (9.84) or 400 (15.75).
Pointek CLS300 - Threaded Process Connections, dimensions in mm (inch)
Siemens FI 01 · 2015
4/61
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Standard and Digital
Rod version
Welded flange (7ML5650 and 7ML5660)
High temperature rod version
Welded flange (7ML5652 and 7ML5662)
Lid
Lid clip
Electronics/
enclosure
Ø19 (0.75)
185 (7.28)
Lid with window
Thermal
isolator
Ø19 (0.75)
Cable version, non-insulated
Welded flange (7ML5651 and 7ML5661)
Cable version, insulated
Welded flange (7ML5651 and 7ML5661)
Flange Facing (raised face)
Ø32 (1.26)
2 (0.08)
ASME 600/900
7 (0.28)
PN16/40
2 (0.08)
Y01 (insertion length)
min. = 500 (20)/max. = 25 000 (984)
Y02
Stainless
steel weight
Measuring length
Ø10 (0.35)
Ø32 (1.26)
Note:
1)
Extended Active Shield (Y02): standard length 105 (4.13). Optional active shield lengths: 230 (9.06) or 380 (14.96).
Insertion length does not include any raised face/gasket face dimension (see Flange Facing Table above)
Pointek CLS300 - Flanged Process Connections, dimensions in mm (inch)
4/62
Siemens FI 01 · 2015
Facing thickness
ASME 150/300
1)
PFA insulated
cable
250 (9.84)
250 (9.84)
Ø6 (0.24)
Y01 (insertion length)
min. = 500 (20)/max. = 25 000 (984)
Stainless
steel cable
Measuring length
Y02 1)
Flange Class
Stainless
steel weight
260 (10.24)
273 (10.75)
Lid without window
171
(6.73)
Y01 (insertion length)
min. = 250 (9.8)/max. = 1 000 (39.37)
Probe
Y02 1)
Ceramic
isolator(s)
M20: 135 (5.32)
½" NPT: 150 (5.91)
Measuring length
Probe
Thermal
isolator
Y01 (insertion length)
min. = 250 (9.8)/max. = 1 000 (39.37)
4
Measuring length
Y02 1)
2 cable entries
½" NPT or
M20 x 1.5
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Standard and Digital
■ Schematics
Wiring: Pointek CLS300 standard
White
Black
Red
P2
(f )
(+)
Switch bank
Trip
point
S1
P1
K1
OFF
GND
3
+
Delay
2
1
K4
Sensor
L1
L2
L3
Sensor
status
Power
on
1
2
3
Power
supply
12 to 250 V AC/DC
Output
status
NC
NO
4
NO
K3
K2
Solid state switch:
30 V DC/30 V AC
(peak),
82 mA max.
Relay contact:
8 A at 250 V AC, 2 000 VA
5 A at 30 V DC, 150 W
Notes:
- Identification label is on underside of lid. Switch and potentiometer settings
are for illustration purposes only (refer to operation/setup in manual).
- All field wiring must have insulation suitable for at least 250 V.
- Relay contact terminals are for use with equipment having no accessible live
parts and wiring having insulation suitable for at least 250 V.
- Maximum working voltage between adjacent relay contacts shall be 250 V.
- Refer to the Instruction manual or contact Siemens representative for detailed
wiring information.
Wiring: Pointek CLS300 digital
White
Test input
Reed
contact*
White
Red (+)
Black (-)
Sensor
Alarm output
solid-state switch
Orange (f)
24 V DC/PROFIBUS PA
Power connection:
24 V DC or PROFIBUS PA bus
(not polarity sensitive).
Notes:
Refer to the instruction manual or contact a Siemens representative
for detailed wiring information.
*Magnet activated sensor test
A magnet can be used to test the sensor without opening the lid of the
Pointek CLS300 digital version. Bring the magnet close to the test area
indicated on the enclosure. The sensor test starts and finishes
automatically after 10 seconds.
Pointek CLS300 connection
Siemens FI 01 · 2015
4/63
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS500
■ Overview
■ Configuration
Installation
4
Pointek CLS500 is an inverse frequency shift capacitance level
and material detection switch ideal for detecting interfaces,
solids, liquids, toxic, and aggressive chemicals in critical conditions of high temperature and pressure. CLS500 also has the
ability to tune out build-up on the probe.
Keep unit out of path of falling material, or protect probe from
falling material.
■ Benefits
• Patented Active-Shield technology so measurement is
unaffected by material buildup in active shield section
• 2-wire loop powered with solid-state switch or 4 to 20/20 to
4 mA output
• Simple push-button calibration and integrated local display
• Full function diagnostics
• HART communications for remote commissioning and
inspection
Build up of material in active shield area does not affect
switch operation.
■ Application
Patented Active-Shield technology ensures that measurement is
unaffected by vapors, product deposits, dust and condensation.
The unique mechanical probe design coupled with a high
performance transmitter gives superior performance in a wide
range of level detection applications.
Pointek CLS500’s microprocessor-based electronics provide
one-point calibration, making setup possible without shutting
down your production process.
• Key Applications: foam or liquid/foam level, glycol regenerators, high-pressure coalescers, LNG applications
50 (2)
Install probe at least 50 (2) from tank wall.
Pointek CLS500 installation, dimensions in mm (inch)
4/64
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS500
■ Technical specifications
Design
Input
Measuring range
0 ... 330 pF
Span
Min. 1 pF
Output
Solid-state switch
• Output
• Protection
• Max. switching voltage
• Max. load current
• Voltage drop
• Time delay
(pre or post switching)
Current loop
Galvanically isolated
Against reversed polarity (bipolar)
• 30 V (DC)
• 30 V peak (AC)
82 mA
< 1 V, typical at 50 mA
1 ... 60 s
Material
• Wetted parts material
- Standard rod
• Probe isolation (rod)
Probe diameter
• Standard rod version (PFA)
• High temperature rod version
(Stainless steel)
Probe length
• Standard rod version (PFA)
• High temperature rod version
(Stainless steel)
4 ... 20 mA/20 ... 4 mA
Accuracy (transmitter)
Process connection of probe
• Threaded mounting
316L stainless steel
PFA
16 mm (0.63 inch)
19 mm (0.75 inch)
Max. 1 000 mm (39.4 inch) with
16 mm (0.63 inch) diameter probe
Max. measuring length 1 000 mm
(39.4 inch) with 19 mm (0.75 inch)
diameter probe
NPT [(Taper), ANSI/ASME B1.20.1]
R [(BSPT), EN 10226/PT (JIS-T),
JIS B 0203]
G [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
ASME, EN 1092-1
Temperature stability
0.15 pF (0 pF) or < 0.25 %
(typical < 0.1 %) of actual measurement value, whichever is greater
over the full temperature range
Non-linearity and repeatability
0.1 % of full scale and actual
measurement respectively
Accuracy
Deviation < 0.1 % of measured value
Enclosure
• Material
Indoor/outdoor
• Cable inlet
• Degree of protection
Aluminum, epoxy-coated (Stainless
steel option available.
Contact [email protected])
2 x ½" NPT
Type 4X/NEMA4X/IP65, IP68
Power supply
Max. 33 V DC
• Flange mounting
Rated operating conditions1)
Installation conditions
- Location
Ambient conditions
• Ambient temperature (transmitter)
• Installation category
• Pollution degree
Medium conditions
• Relative dielectric constant r
• Process temperature
- Standard (PFA)
- High temperature stainless steel
version with thermal isolator
- Cryogenic version
-40 ... +85 °C (-40 ... +185 °F)2)
I
4
Min. 1.5
Temperature ratings are pressure
dependent.
See Pressure/Temperature curves
on page 4/72.
-50 ... +200 °C (-58 ... +392 °F)
-60 ... +400 °C (-76 ... +752 °F)
-200 ... +200 °C (-328 ... +392 °F)
Contact [email protected]
for details.
Process pressure
• Standard (PFA)
• High temperature version
(Stainless steel)
Pressure rating of process seal is
temperature dependent.
See Pressure/Temperature curves
on page 4/72.
-1 ... +150 bar g
(-14.6 ... +2 175 psi g)
-1 ... +35 bar g
(-14.6 ... +507.6 psi g)
Features
Measurement current signaling
NAMUR NE 43
Safety
• Inputs/outputs fully galvanically
isolated
• Polarity-insensitive current loop
• Fully potted
• Integrated safety barrier
Primary variable (PV) out of limits,
system failure in measurement circuit,
deviation between A/D and D/A converter, check sum, watch dog and
self-checking facility
Positions 0 ... 9, A ... F
Conforming to HART Communication
Foundation (HCF)
• Diagnostics with fault alarm when:
• Function rotary switch
• SMART communication
Certificates and approvals
• General Purpose
• Non incendive/Non sparking
• Dust Ignition Proof
• Explosion Proof
• Marine
CE, CSA/FM, RCM
CSA/FM Class I, Div. 2,
Groups A, B, C, D T4
ATEX II 3G 2D EEx n A [ib] IIC
T6 ... T4 T100 °C
CSA/FM Class II and III, Div. 1,
Groups E, F, G T4
ATEX II 1/2 GD EEx d [ia] T6 ... T1
T100 °C
FM Class 1, Div. 1,
Groups A, B, C, D T4
ATEX II 1/2 GD EEx d [ia] IIC T6 ... T1
T100 °C
Lloyds Register of Shipping,
Categories ENV1, ENV2, ENV3,
ENV5, Bureau Veritas
1)
When operation is in areas classified as hazardous, observe restrictions
according to relevant certificate.
See also Pressure/Temperature curves on page 4/72.
2)
Thermal isolator is used if process connection temperature exceeds 85 °C
(185 °F)
Siemens FI 01 · 2015
4/65
4
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS500
Pointek CLS500 probe version
Standard
HT Series
Process connection types
Standard (PFA)
(7ML5601, 7ML5602, 7ML5603)
High Temperature
(Stainless steel) (7ML5604)
Threaded
Available as standard
–
Flange
Available as standard
Available as standard
Available as standard
Available as standard
None
–
HT Stainless: available as standard
PFA
Available as standard
–
1 000 mm (40 inch)
1 000 mm (40 inch)
Max. process pressure
150 bar g (2 175 psi g)
Stainless steel:2) 35 bar g (507 psi g)
Max. process temperature
200 °C (392 °F)
400 °C (752 °F)
Process connection materials
316L stainless steel
Probe insulation
Length parameters
Max. rod length
Process condtitions1)
4
1)
When operation is in areas classified as hazardous, observe restrictions according to relevant certificate.
See also Pressure/Temperature curves on page 4/72. Pressure rating of process seal is temperature dependent.
2)
Pressure rating of process seal is temperature dependent. See Pressure/Temperature curves on page 4/72.
– Not available as standard
4/66
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS500
Selection and Ordering data
Article No.
Selection and Ordering data
Pointek CLS500, threaded
Inverse frequency shift capacitance level and
material detection switch for detecting interfaces,
solids, liquids, toxic and aggressive chemicals in
critical conditions of extreme temperature and
pressure. CLS500 also has the ability to tune out
build-up on the probe.
7ML5601-
Further designs
77 7 77 - 77 A 0
Please add "-Z" to Article No. and specify Order
code(s).
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Electronic transmitter
No transmitter supplied
MSP 2002-1 (330 pF)
0
1
Process connection
¾"
1"
1¼"
A
B
C
1½"
2"
D
E
Threaded connection and rating
NPT [(Taper), ANSI/ASME B1.20.1]
R [(BSPT), EN 10226/PT (JIS-T) JIS B 0203]
G [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
Probe insulation/material of process connection
PFA insulation/316L stainless steel
A
B
D
Active Shield length - minimum length is 50 mm
Y02: to mm1)
Y02
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 27 characters) specify in plain text
Y15
Manufacturer's test certificate: M to DIN 55350,
Part 18 and to ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Note: The Operating Instructions should be
ordered as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
manual library.
See page 4/71
Pointek Specials
See page 4/71
See dimension drawings on page 4/77 for further explanation of Y02
1
ATEX II 1/2 GD EEx d [ia] IIC T6 to T1 T100 °C
FM Class I, Div. 1, Groups A, B, C, D T4
4
6
1)
Y01
1)
1
2
Thermal isolator/remote version
Rigid thermal isolator [for process connection
temperature over 85 °C (185 °F)]
No thermal isolator
Total insertion length: enter the total insertion length
in plain text description
Operating Instructions
Approvals
General Purpose: CE, CSA/FM, RCM
CSA/FM Class I, Div. 2, Groups A, B, C, D T4;
ATEX II 3GD 2D EEx nA [ib] IIC T6 to T4 T100 °C;
CSA/FM Class II and III Div. 1, Groups E, F, G T4
Probe/electrode diameter
16 mm (0.63 inch) rigid rod, minimum insertion
length 200 mm (7.9 inch), maximum insertion
length 1 000 mm (39.4 inch)1)
Order code
1
A
B
Add Order code Y01 and Y02 in plain text:
"Insertion/active shield length to mm"
Siemens FI 01 · 2015
4/67
4
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS500
Selection and Ordering data
Article No.
Selection and Ordering data
Pointek CLS500, welded flange
Inverse frequency shift capacitance level and
material detection switch for detecting interfaces,
solids, liquids, toxic and aggressive chemicals in
critical conditions of extreme temperature and
pressure. CLS500 also has the ability to tune out
build-up on the probe.
7ML5602-
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
77 7 77 - 77 A 0
Total insertion length: enter the total insertion length
in plain text description
Y01
Active Shield length - minimum length is 50 mm.
Y02: to mm1)
Y02
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 27 characters) specify in plain text
Y15
Manufacturer's test certificate: M to DIN 55350,
Part 18 and to ISO 9000
C11
AA
AB
BA
BB
Inspection Certificate Type 3.1 per EN 10204
C12
4" ASME, 150 lb1)
4" ASME, 300 lb1)
6" ASME, 150 lb1)
6" ASME, 300 lb1)
Welded flange, 316L stainless steel,
Type A flat faced
DN 50 PN 16
DN 50 PN 40
DN 80 PN 16
CA
CB
DA
DB
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
manual library.
DN 80 PN 40
DN 100 PN 161)
DN 125 PN 161)
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5 or EN 1092-1 standard.)
FD
GC
HC
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Electronic transmitter
MSP 2002-1 (330 pF)
4
Order code
Process connection and pressure rating
Welded flange, 316L stainless steel, raised face
2" ASME, 150 lb
2" ASME, 300 lb
3" ASME, 150 lb
3" ASME, 300 lb1)
Probe insulation/material of process connection
PFA insulation/316L stainless steel
Approvals
General Purpose
CSA/FM Class I, Div. 2, Groups A, B, C, D T4;
ATEX II 3GD 2D EEx nA [ib] IIC T6 to T4 T100 °C;
CSA/FM Class II and III Div. 1, Groups E, F, G T4
ATEX II 1/2 GD EEx d [ia] IIC T6 to T1 T100 °C
FM Class I, Div. 1, Groups A, B, C, D T4
Probe/electrode diameter
16 mm (0.63 inch) rigid rod, min. length 200 mm
(7.9 inch), max. length 1 000 mm (39.4 inch)
Thermal isolator
Rigid thermal isolator
[for process temperature over 85 °C (185 °F)]
No thermal isolator
1)
1
Operating Instructions
Note: The Operating Instructions should be
ordered as a separate line on the order.
Pointek Specials
1)
EC
ED
FC
1
1
2
4
6
1
A
B
Custom shipping methods required. Contact factory for more details.
4/68
Siemens FI 01 · 2015
See page 4/71
See page 4/71
See dimensional drawings on page 4/77 for further explanation of Y02
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS500
Selection and Ordering data
Pointek CLS500, single piece flange
Inverse frequency shift capacitance level and
material detection switch for detecting interfaces,
solids, liquids, toxic and aggressive chemicals in
critical conditions of extreme temperature and
pressure. CLS500 also has the ability to tune out
build-up on the probe.
Article No.
77 7 77 - 77 A 0
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Electronic transmitter
MSP 2002-1 (330 pF)
1
Process connection and pressure rating
Single piece flange, 316L stainless steel,
raised face
2" ASME, 150 lb
2" ASME, 300 lb
AA
AB
3" ASME, 150 lb
3" ASME, 300 lb1)
BA
BB
4" ASME, 150 lb1)
4" ASME, 300 lb1)
CA
CB
6" ASME, 150 lb1)
6" ASME, 300 lb1)
Single piece flange, 316L stainless steel,
Type B1 raised faced
DA
DB
DN 50 PN 16
DN 50 PN 25
EC
ED
DN 80 PN 16
DN 80 PN 25
FC
FD
DN 100 PN 161)
DN 100 PN 251)
GC
GD
DN 125 PN 161)
DN 125 PN 251)
HC
HD
Probe insulation/material of process connection
PFA insulation/316L stainless steel
Y01
Active Shield length - minimum length is 50 mm.
Y02: to mm1)
Y02
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 27 characters) specify in plain text
Y15
Manufacturer's test certificate: M to DIN 55350,
Part 18 and to ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Note: The Operating Instructions should be
ordered as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
manual library.
See page 4/71
Accessories
See page 4/71
See dimensional drawings on page 4/77 for further explanation of Y02
1
ATEX II 1/2 GD EEx d [ia] IIC T6 to T1 T100 °C
FM Class I, Div. 1, Groups A, B, C, D T4
4
6
1)
Total insertion length: enter the total insertion length
in plain text description
1)
1
2
Thermal isolator
Rigid thermal isolator [for process connection
temperature over 85 °C (185 °F)]
No thermal isolator
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
Operating Instructions
Approvals
General Purpose: CE, CSA/FM, RCM
CSA/FM Class I, Div. 2, Groups A, B, C, D T4;
ATEX II 3GD 2D EEx nA [ib] IIC T6 to T4 T100 °C;
CSA/FM Class II and III Div. 1, Groups E, F, G T4
Probe/electrode diameter
16 mm (0.63 inch) rigid rod,
maximum length 1 000 mm (39.4 inch) (Y01)
Order code
Selection and Ordering data
7ML5603-
1
A
B
Custom shipping methods required. Contact factory for more details
Siemens FI 01 · 2015
4/69
4
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS500
Selection and Ordering data
Article No.
Selection and Ordering data
Article No.
Pointek CLS500 High temperature
Inverse frequency shift capacitance level and
material detection switch for detecting interfaces,
solids, liquids, toxic and aggressive chemicals in
critical conditions of extreme temperature and
pressure. CLS500 also has the ability to tune out
build-up on the probe.
7ML5604-
Pointek CLS500 High temperature
Inverse frequency shift capacitance level and
material detection switch for detecting interfaces,
solids, liquids, toxic and aggressive chemicals in
critical conditions of extreme temperature and
pressure. CLS500 also has the ability to tune out
build-up on the probe.
7ML5604-
7A 7 77 - 7777
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Electronic transmitter
MSP 2002-1 (330 pF)
4
Probe material of process connection
No insulation/316L stainless steel3)4)
Stilling well
No stilling well
1
Process connection and pressure rating
316L stainless steel, raised face1)
2" ASME, 150 lb
2" ASME, 300 lb
2" ASME, 600 lb
2" ASME, 900 lb
A1
A2
A3
A4
3" ASME, 150 lb
3" ASME, 300 lb2)
3" ASME, 600 lb2)
3" ASME, 900 lb2)
B1
B2
B3
B4
4" ASME, 150 lb2)
4" ASME, 300 lb2)
4" ASME, 600 lb2)
4" ASME, 900 lb2)
C1
C2
C3
C4
lb2)
6" ASME, 150
6" ASME, 300 lb2)
6" ASME, 600 lb2)
6" ASME, 900 lb2)
316L stainless steel, Type B1 flat faced
D1
D2
D3
D4
DN 50 PN 16
DN 50 PN 25
DN 50 PN 40
DN 50 PN 63
E1
E2
E3
E4
DN 80 PN 16
DN 80 PN 25
DN 80 PN 402)
DN 80 PN 632)
F
F
F
F
DN 100 PN 162)
DN 100 PN 252)
DN 100 PN 402)
DN 100 PN 642)
G1
G2
G3
G4
DN 125 PN 162)
DN 125 PN 252)
DN 125 PN 402)
DN 125 PN 642)
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5 or EN 1092-1 standard.)
H1
H2
H3
H4
4/70
Siemens FI 01 · 2015
7 A 7 77 - 7777
1
2
3
4
1
0
Approvals
General Purpose
CSA/FM Class I, Div. 2, Groups A, B, C, D T4;
ATEX II 3GD 2D EEx nA [ib] IIC T6 to T4 T100 °C;
CSA/FM Class II and III Div. 1, Groups E, F, G T4
A
B
ATEX II 1/2 GD EEx d [ia] IIC T6 to T1 T100 °C
FM Class I, Div. 1, Groups A, B, C, D T4
D
F
Probe/electrode diameter
Maximum length 1 000 mm (39.37 inch)4)
Thermal isolator
Rigid thermal isolator [for process connection
temperature over 85 °C (185 °F)]
A
1
1)
Welded flange for no insulation option only
2)
Custom shipping methods required
3)
Non-conductive material only, stainless steel non-insulated probe diameter
19 mm (0.75 inch)
4)
Add Order code Y01 and Y02 in plain text:
"Insertion/active shield length to mm"
Minimum insertion length depends on probe version selected.
See dimensional drawings on page 4/77 for more details.
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS500
Selection and Ordering data
Order code
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
Total insertion length: enter the total insertion length
in plain text description
Y01
Active Shield length - minimum length is 50 mm.
Y02: to mm1)
Y02
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 27 characters) specify in plain text
Y15
Manufacturer's test certificate: M to DIN 55350,
Part 18 and to ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Operating Instructions
Article No.
English
7ML1998-5GG03
German
7ML1998-5GG32
French
7ML1998-5GG11
Dutch
Note: The Operating Instructions should be
ordered as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
7ML1998-5GG41
Quick Start manual, multi-language
A5E32243995
4
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
Accessories
General Purpose
1/2" NPT General Purpose Cable Entry IP68/IP69K
NEMA6, -40 ... -100 °C (-40 ... -212 °F), cable size
6 ... 12 mm (0.236 ... 0.472 inch)
7ML1830-1JA
M20x1.5 General Purpose Cable Entry IP68/IP69K
NEMA6, -40 ... -100 °C (-40 ... -212 °F), cable size
7 ... 12 mm (0.275 ... 0.472 inch)
7ML1830-1JC
Transmitter, MSP 2002-1, 330 PF
7ML1830-1JP
Hazardous Locations
1/2" NPT EMC rated Cable Gland: Dust Ignition Proof, 7ML1830-1JB
Flameproof Exd, and Increased Safety ATEX II 2 GD
ExtD A21 (Zone 1, Zone 2, Zone 21, Zone 22, and in
Gas Groups IIA,IIB and IIC) -60 ... +80 °C IP66, IP67,
IP68, NEMA4X, cable sizes 5.5 ... 12 mm
(0.216 ... 0.472 inch)
M20 EMC rated Cable Gland: Dust Ignition Proof,
Flameproof Exd, and Increased Safety ATEX II 2 GD
ExtD A21 (Zone 1, Zone 2, Zone 21, Zone 22 and in
Gas Groups IIA,IIB and IIC) -60 ... +80 °C IP66, IP67,
IP68, NEMA4X, cable sizes 5.5 ... 12 mm
(0.216 ... 0.472 inch)
7ML1830-1JD
Pointek Specials
See page 4/80
1)
See dimensional drawings on page 4/77 for further explanation of Y02
Siemens FI 01 · 2015
4/71
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS500
■ Characteristic curves
Pressure/temperature curve
CLS500 rod probes
Threaded process connections
(7ML5601)
Permitted operating pressures P
150 bar (2.175 psi)
140 bar (2.030 psi)
130 bar (1.885 psi)
4
120 bar (1.740 psi)
110 bar (1.595 psi)
100 bar (1.450 psi)
90 bar (1.305 psi)
80 bar (1.160 psi)
70 bar (1.015 psi)
60 bar (870 psi)
50 bar (725 psi)
40 bar (580 psi)
30 bar (435 psi)
20 bar (290 psi)
10 bar (145 psi)
Atmospheric
-40 ºF 14 ºF
(-40 ºC)(-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
-29 ºC
(-20 ºF)
Example:
Permitted operating pressure = 137 bar (1988 psi) at 75 °C
Pointek CLS500 Process Pressure/Temperature derating curves (7ML5601)
4/72
Siemens FI 01 · 2015
300 ºF
(149 ºC)
150 ºC
(302 ºF)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted operating temperature T
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS500
Pressure/temperature curve
CLS500 rod probes
ASME flanged process connections
(7ML5602 and 7ML5603)
Permitted operating pressures P
150 bar (2.175 psi)
140 bar (2.030 psi)
130 bar (1.885 psi)
120 bar (1.740 psi)
4
110 bar (1.595 psi)
100 bar (1.450 psi)
90 bar (1.305 psi)
80 bar (1.160 psi)
70 bar (1.015 psi)
60 bar (870 psi)
50 bar (725 psi)
40 bar (580 psi)
30 bar (435 psi)
ASME 300 lb1)
20 bar (290 psi)
Atmospheric
-40 ºF 14 ºF
(-40 ºC)(-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
ASME 150 lb1)
10 bar (145 psi)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
-29 ºC
(-20 ºF)
1)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted operating temperature T
The curve denotes the minimum allowable flange class for the shaded area below.
Pointek CLS500 Process Pressure/Temperature derating curves (7ML5602 and 7ML5603)
Siemens FI 01 · 2015
4/73
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS500
Pressure/temperature curve
CLS500 rod probes
EN flanged process connections
(7ML5602 and 7ML5603)
Permitted operating pressures P
150 bar (2.175 psi)
140 bar (2.030 psi)
130 bar (1.885 psi)
120 bar (1.740 psi)
4
110 bar (1.595 psi)
100 bar (1.450 psi)
90 bar (1.305 psi)
80 bar (1.160 psi)
70 bar (1.015 psi)
60 bar (870 psi)
50 bar (725 psi)
40 bar (580 psi)
30 bar (435 psi)
20 bar (290 psi)
PN 251)
-40 ºF 14 ºF
(-40 ºC)(-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
PN 161)
10 bar (145 psi)
Atmospheric
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
-29 ºC
(-20 ºF)
1)
The curve denotes the minimum allowable flange class for the shaded area below.
Pointek CLS500 Process Pressure/Temperature derating curves (7ML5602 and 7ML5603)
4/74
Siemens FI 01 · 2015
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted operating temperature T
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS500
Pressure/temperature curve
CLS500 high temperature (no insulation)
ASME flanged process connections
(7ML5604)
Permitted operating pressures P
90 bar (1.305 psi)
80 bar (1.160 psi)
70 bar (1.015 psi)
4
60 bar (870 psi)
ASME 600 lb
50 bar (725 psi)
1)
40 bar (580 psi)
30 bar (435 psi)
ASME 300 lb1)
20 bar (290 psi)
ASME 150 lb1)
Atmospheric
10 bar (145 psi)
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
-29 ºC
(-20 ºF)
1)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted operating temperature T
The curve denotes the minimum allowable flange class for the shaded area below.
Pointek CLS500 Process Pressure/Temperature derating curves (7ML5604)
Siemens FI 01 · 2015
4/75
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS500
Pressure/temperature curve
CLS500 high temperature (no insulation)
EN flanged process connections
(7ML5604)
Permitted operating pressures P
40 bar (580 psi)
30 bar (435 psi)
PN 401)
20 bar (290 psi)
PN 251)
4
10 bar (145 psi)
Atmospheric
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
PN 161)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
-29 ºC
(-20 ºF)
1)
The curve denotes the minimum allowable flange class for the shaded area below.
Pointek CLS500 Process Pressure/Temperature derating curves (7ML5604)
4/76
Siemens FI 01 · 2015
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted operating temperature T
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS500
■ Dimensional drawings
Standard rod version
Threaded (7ML5601)
205 (8.1)
Standard configuration
(7ML5601)
Transmitter/
electronics
1/2" NPT:
230 (9.1)
With thermal isolator option
(all versions)
Thermal
isolator
4
430 (16.9)
270 (10.6)
With explosion-proof seal option
(all versions)
Measuring length
30 (1.18)
PFA insulated
probe
Y02
Y01 (insertion length)
min. = 200 (7.87) / max. = 1 000 (39.37)
20 (0.79)
Inactive tip
Ø16 (0.63)
Pointek CLS500 - Threaded Process Connections, dimensions in mm (inch)
Siemens FI 01 · 2015
4/77
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS500
Standard Rod version
Welded Flange (7ML5602)
Single Piece Flange (7ML5603)
205 (8.1)
Standard configuration
(7ML5602, 7ML5603)
Transmitter/
electronics
30 (1.18)
PFA insulated
probe
With thermal isolator option
(all versions)
430 (16.9)
Measuring length1)
4
With explosion-proof seal option
(all versions)
270 (10.6
Y021)
Y01 (insertion length)
min. = 200 (7.87)/max. = 1 000 (39.37)
½" NPT:
230 (9.1)
Thermal
isolator
Inactive tip
Ø16 (0.63)
High temperature rod version
Welded Flange (7ML5604), Stainless steel rod 4)
Flange Facing (raised face)
Flange Class
Thermal
isolator
Facing thickness
ASME 150/300
2 (0.08)
ASME 600/900
7 (0.28)
PN16/25/40/64
2 (0.08)
Notes:
1)
Min. Y02 (active shield length) = 50 (1.96)
Min. Y02 (active shield length) = 105 (4.13)
3)
Min. Y02 (active shield length) = 100 (3.94)
4)
Non conductive materials only
Stainless steel
probe
Measuring
Y02 2)
length2)
Y01 (insertion length)
min. = 200 (7.87)/max. = 1 000 (39.37)
2)
Ø19 (0.75)
Pointek CLS500 - Flanged Process Connections, dimensions in mm (inch)
4/78
Siemens FI 01 · 2015
Insertion length does not include any raised
face/gasket face dimension (see Flange
Facing Table above)
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS500
■ Schematics
Ground lug
Protective
label
Solid state
switch relay
(any polarity)
Instrument
system
ground
Measuring
signal
(minicoaxial
cable)
Type:
Ser.:
Date:
Rev.:
4 ... 20 mA
current loop
connection
(any polarity)
Tampering voids warranty
4
Ground connection
point for instrument
system
Pointek CLS500 connections
Siemens FI 01 · 2015
4/79
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS Specials
■ Selection and ordering data
Pointek Specials1)
Pointek Specials1)
Article No.
A5E01163678
Kit, Sensor for cable units, PPS, Standard,
FFKM
A5E01163679
Kit, Sensor for cable units, PPS, Digital,
FFKM
A5E01163680
Kit, Sensor for cable units, PVDF, Standard,
FKM
A5E01163681
Kit, Sensor for cable units, PVDF, Digital,
FKM
A5E01163682
CLS100 Miscellaneous Parts
Custom length of cable is available only for
7ML5501-xxx1x and 7ML5501-xxx5x2)
Kit, Sensor for cable units, PVDF, Standard,
FFKM
A5E01163683
CLS200 Gasket (IP65), Synprene
Kit, Sensor for cable units, PVDF, Digital,
FFKM
A5E01163684
Kit, Lid and gasket,
CLS100 enclosure version
4
Article No.
Kit, Sensor for cable units, PPS, Digital,
FKM
CLS100 Polycarbonate Lid and Gasket, FKM
A5E01163671
CLS200 Mounting Bracket,
316L stainless steel
Spare gasket, enclosure version
(IP65 versions only)
A5E01163672
CLS200 Gasket (IP68), Silicone
Spare mounting bracket
A5E01163685
CLS200 PROFIBUS Connector (IP65)
Spare gasket, enclosure version
(IP68 versions)
A5E01163673
Spare, PROFIBUS connector
(IP65 versions only)
CLS200 Blind Lid
A5E01163686
CLS200 Miscellaneous Parts
CLS200 with FFKM O-rings (any version)2)
CLS200 Electronics
Spare aluminum blind lid
(for standard versions only)
A5E01163674
CLS200 Lid with window
Test magnet, digital version
7ML1830-1JE
Amplifier/power supply kit, standard version
A5E03251681
Amplifier/power supply, digital version
7ML1830-1JF
LCD display, digital version
7ML1830-1JK
CLS300 Cable Extensions,
316L stainless steel
Spare aluminum lid with window
A5E01163676
CLS200 Sensor Kit for cable units
Kit, Sensor for cable units, PPS, Standard, FKM
4/80
Siemens FI 01 · 2015
A5E01163677
Kit, stainless steel cable extension, 1 m,
adjustable by customer
A5E01163688
Kit, stainless steel cable extension, 3 m,
adjustable by customer
A5E01163689
Kit, stainless steel cable extension, 5 m,
adjustable by customer
A5E01163690
Kit, stainless steel cable extension, 10 m,
adjustable by customer
A5E01163691
Kit, stainless steel cable extension, 15 m,
adjustable by customer
A5E01163693
Kit, stainless steel cable extension, 20 m,
adjustable by customer
A5E01163695
© Siemens AG 2014
Level Measurement
Point level measurement – Capacitance switches
Pointek CLS Specials
Pointek Specials1)
Pointek Specials1)
Article No.
CLS300 Cable Extensions,
316 stainless steel with PFA coating
Article No.
CLS300 Electronics Kits with drivers
(for rod or cable versions)
Kit, PFA cable extension, 1 m,
adjustable by customer
A5E01163697
Kit, PFA cable extension, 3 m,
adjustable by customer
A5E01163698
Kit, PFA cable extension, 5 m,
adjustable by customer
A5E01163699
Kit, PFA cable extension, 10 m,
adjustable by customer
A5E01163700
Kit, PFA cable extension, 15 m,
adjustable by customer
A5E01163701
Kit, PFA cable extension, 20 m,
adjustable by customer
A5E01163702
CLS300 Rod Kits, 316L stainless steel
Kit, Electronics with driver, standard CLS300.
To be used in rod or cable versions with
length less than 5 m.3)4)
A5E01163723
Kit, Electronics with driver, digital CLS300.
To be used in rod or cable versions with
length less than 5 m.3)4)
A5E01163725
CLS300 Electronics Kits with drivers
(for cable versions)
Kit, Electronics with driver, standard CLS300.
To be used in cable versions with
length greater than 5 m.3)4)
A5E01163724
Kit, Electronics with driver, digital CLS300.
To be used in cable versions with
length greater than 5 m.3)4)
A5E01163726
CLS300 Electronics
Kit, stainless steel rod 180 mm (7.09 inch) to
be used with CLS300 units only (with standard
active shield). Insertion length after installation
is 350 mm (13.78 inch).
A5E01163719
Kit, stainless steel rod 330 mm (12.99 inch) to
be used with CLS300 units only (with standard
active shield). Insertion length after installation
is 500 mm (19.69 inch).
A5E01163720
Kit, stainless steel rod 580 mm (22.83 inch) to
be used with CLS300 units only (with standard
active shield). Insertion length after installation
is 750 mm (29.53 inch).
A5E01163721
Kit, stainless steel rod 830 mm (32.68 inch) to
be used with CLS300 units only (with standard
active shield). Insertion length after installation
is 1 000 mm (39.37 inch).
A5E01163722
Kit, stainless steel rod 1 330 mm (52.36 inch) to
be used with CLS300 units only (with standard
active shield). Insertion length after installation
is 1 500 mm (59.06 inch).2)
Kit, stainless steel rod 1 830 mm (72.05 inch) to
be used with CLS300 units only (with standard
active shield). Insertion length after installation
is 2 000 mm (78.74 inch).2)
Test magnet, digital version
7ML1830-1JE
Amplifier/power supply kit, standard version
A5E03251683
Amplifier/power supply, digital version
7ML1830-1JF
LCD display, digital version
7ML1830-1JK
CLS300 Weight Kit, 316L stainless steel
Kit, Spare stainless steel weight. To be used in
any cable version of CLS300
A5E01163727
CLS500 Gasket (IP65), Silicone
Spare gasket, CLS500 enclosure version, IP65
A5E01163728
CLS500 Blind Lid
Spare CLS500 aluminum blind lid
A5E01163729
Kit, stainless steel rod customized length
up to 1 m2)
CLS500 Electronics Kit
Kit, stainless steel rod customized length
up to 2 m2)
1)
Special flange sizes and facings are available. Please contact
[email protected] for part number and pricing. Submit Application
Questionnaire found on page 4/11.
2)
Please contact [email protected] for part number and pricing.
3)
For General Purpose approvals only.
4)
To maintain approvals, qualified trained Siemens personnel
required for part replacement.
Transmitter, MSP 2002-1, 330 PF
7ML1830-1JP
Please contact [email protected] for special requests.
Siemens FI 01 · 2015
4/81
4
© Siemens AG 2014
Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL100
■ Overview
■ Configuration
Horizontal mounting
Switching point
Switching point
(recommended mounting
position, particularly for
adhesive applications)
Vertical mounting
SITRANS LVL100 is a compact vibrating level switch for material
detection in liquid and slurry applications such as overflow, high,
low and demand applications, as well as pump protection.
It is ideal for use in confined spaces.
13 (0.51)
4
13 (0.51)
Switching point
with
lower density
Switching point
[approx. 13 (0.51)]
■ Benefits
• Proven vibrating level switch technology for liquids
• Compact insertion length of 40 mm (1.57 inch) for confined
space applications
• Fault monitoring for corrosion, loss of vibration, or line break to
the piezo drive
• Integrated test function to confirm correct operation
■ Application
SITRANS LVL100 is a compact level switch designed for industrial use in all areas of process technology and can be used for
material detection with liquids and slurries. With an insertion
length of only 40 mm (1.57 inch), SITRANS LVL100 can be
mounted in small pipes and confined space applications. It is
virtually unaffected by the chemical and physical properties of
the liquid. The LVL100 can be used in difficult conditions including turbulence, air bubbles, foam generation, buildup, or external vibration.
The tuning fork is piezoelectrically energized and vibrates at a
mechanical resonance frequency of approximately 1 200 Hz.
The vibration frequency changes when the tuning fork is covered by the medium. This change is detected by the integrated
oscillator and converted into a switching command. The integrated electronics evaluate the level signal and output a switching signal to connected devices.
• Key Applications: For use in liquids and slurries, for level
measurement, overfill, and dry run protection
Switching point
with
higher density
Horizontal mounting in
viscous or adhesive
applications
Moisture protection
30 (1.18)
NOTE:
Welded socket for flush
mount optional.
Ensure cable gland faces
downward to avoid water
ingress.
SITRANS LVL100 Installation, dimensions in mm (inch)
4/82
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL100
■ Technical specifications
■ Options
Mode of operation
Vibrating point level switch
LVL100 threaded welded socket
G¾" A/316L
Input
Measured variable
High and low and demand
32 (1.26)
G¾"
Output
Measuring Accuracy
• Hysteresis
• Switching delay
• Frequency
Approx. 2 mm (0.08 inch) with
vertical installation
Approx. 500 ms (on/off)
Approx. 1 200 Hz
Rated operating conditions
Indoor/outdoor
Ambient conditions
• Ambient temperature
• Installation category
• Pollution degree
-40 ... +70 °C (-40 ... +158 °F)
III
2
Design
Material
• Enclosure
• Tuning fork
• Process connection (threaded)
• Process seal
Process connection
• Pipe thread, cylindrical
(ISO 228 T1)
• Pipe thread, tapered
• Hygienic fittings
Degree of protection
Conduit entry
Weight (housing)
Power supply
Supply voltage
Power consumption
Certificates and approvals
53 (2.09)
60 (2.36)
SITRANS LVL100 welded socket, dimensions in mm (inch)
Installation conditions
• Location
Medium conditions
• Temperature
- Standard
- High temperature option
• Pressure (vessel)
• Density
39 (1.54)
G1"
Contactless electronic switch
Transistor output PNP
32
(1.26)
Output options
G1" A/316L
29.5
(1.16)
Measuring principle
4
-40 ... +100 °C (-40 ... +212 °F)
-40 ... +150 °C (-40 ... +302 °F)
-1 ... 64 bar g (-14.5 ... 928 psi g)
0.7 ... 2.5 g/cm³
(0.025 ... 0.09 lb/in³)
316L and Plastic PEI
316L (1.4404 or 1.4435)
316L (1.4404 or 1.4435)
Klingersil C-4400
G ½" A, G ¾" A or G 1" A
½" NPT, ¾" NPT or 1" NPT
Bolting DN 40 PN 40
Tri-clamp 1", 1½", 2" PN 10
IP65/Type 4/NEMA 4
(with DIN 43650 valve plug),
IP66/67 or IP68
(with M12 connector)
1 x M12 [IP66/IP67 or IP68 (0.2 bar)]
250 g (9 oz)
20 ... 253 V AC, 50/60 Hz
20 ... 253 V DC
Max. 0.5 W
• Overfill protection (WHG)
• Shipping approvals
Siemens FI 01 · 2015
4/83
© Siemens AG 2014
Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL100
Selection and Ordering data
Article No.
Selection and Ordering data
SITRANS LVL100
Compact vibrating level switch for use in liquid and
slurry applications such as overflow, high, low, and
demand applications, as well as pump protection.
Ideal for use in confined spaces.
7ML5745-
Further designs
77 7 77 - 77 A 0
Please add "-Z" to Article No. and specify Order
code(s).
Cleaning including certificate
(oil, grease and silicone free)
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Approvals
Without approvals
Shipping approvals5)
Overfill protection (WHG)1)
4
Process temperature
Standard -40 ... +100 °C (-40 ... +212 °F)2)
Extended -40 ... +150 °C (-40 ... +302 °F)2)
Hygienic applications -40 ... +150 °C
(-40 ... +302 °F)3)
Process connection
Thread G¾" A PN 64/316L
Thread G¾" A PN 64/316L Ra < 0.8 µm
Thread ¾" NPT PN 64/316L
Thread ¾" NPT PN 64/316L Ra < 0.8 µm
Thread G1" A PN 64/316L
Thread G1" A PN 64/316L Ra < 0.8 µm
Thread 1" NPT PN 64/316L
Thread 1" NPT PN 64/316L Ra < 0.8 µm
Tri-Clamp 1" PN 16 DIN 32676/316L Ra < 0.8 µm
¢ 1
¢ 2
¢ 3
¢ Y16
Acceptance test certificate 3.1 for instrument
¢ C12
Acceptance test Certificate 2.2 for material
EN10204
¢ C15
¢
¢
¢
Article No.
LVL100 (Contactless electronic switch)
A
B
C
¢
W01
Identification Label, foil laser marking
Additional Operating Instructions
¢
¢
Order code
A0
A1
A2
• English
7ML1998-5KN01
• French
7ML1998-5KN11
• Spanish
7ML1998-5KN21
• German
7ML1998-5KN31
LVL100 (Transistor PNP)
A3
A4
A5
A6
A7
A8
• English
7ML1998-5KP01
• French
7ML1998-5KP11
• Spanish
7ML1998-5KP21
• German
This device is shipped with the Siemens
Milltronics manual DVD containing the Operating
Instructions library.
7ML1998-5KP31
Tri-Clamp 1½" PN 16 DIN 32676/316L Ra < 0.8 µm
Tri-Clamp 2 " PN 16 DIN 32676/316L Ra < 0.8 µm
Bolting DN25 PN 40 DIN 11851/316L Ra < 0.8 µm
B0
B1
B2
Bolting DN40 PN 40 DIN 11851/316L Ra < 0.8 µm
Bolting DN50 PN 25 DIN 11851/316L Ra < 0.8 µm
SMS DN38 PN 6 316L Ra < 0.8 µm
B3
B4
B5
G¾" A/316L with FKM Seal
7ML1930-1EE
G1" A/316L with FKM Seal
7ML1930-1EF
Hygienic fitting with compression nut F40
PN 25/316L Ra < 0.8 µm
B6
M27x1.5/316L with FKM Seal
7ML1930-1EG
G¾" A/316L with EPDM Seal
7ML1930-1EH
Thread G½" (DIN 3852-A) PN64 / 316L
C0
G1" A/316L with EPDM Seal
7ML1930-1EJ
Thread G½" (DIN 3852-A) PN64 / 316L Ra < 0.8 µm
C1
M27x1.5/316L with EPDM Seal
7ML1930-1EK
Thread ½" NPT (ASME B1.20.1) PN 64/316L
C2
Thread ½" NPT (ASME B1.20.1) PN 64/316L
Ra < 0.8 µm
C3
Electronics
Contactless electronic switch 20 ... 250 V AC/DC4) ¢
Transistor output PNP 10 ... 55 V DC
¢
Housing
316L
Spare Parts
LVL100 Threaded Welded Socket
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
1
2
¢
Electrical connection/Protection
M12x1/IP67
According to DIN 43650 including plug/IP65
Acc. to DIN 43650 incl. plug with QuickOn
connection/IP65
¢
M12x1 incl. 5 m cable/IP68 (0.2 bar)
1)
Available with process connection A0, A2, A4, and A6 only
2)
Available with process connection A1, A3, A5, and A7 ... B6 only
3)
Available with Electrical connection/Protection option B and C only
4)
Available with Process Temperature option A only
1
A
B
C
D
5) Available with Process Temperature option A only
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
4/84
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL100
■ Characteristic curves
Ambient temperature in °C (°F)
Ambient temperature to process temperature dependency
(standard version)
70 ºC
(158 ºF)
50 ºC
(122 ºF)
4
0 ºC
(32 ºF)
-40 ºC
(-40 ºF)
-40 ºC
(-40 ºF)
-20 ºC
(-4 ºF)
0 ºC
20 ºC
40 ºC
60 ºC
80 ºC 100 ºC
(32 ºF) (68 ºF) (104 ºF) (140 ºF) (176 ºF) (212 ºF)
Process temperature in °C (°F)
Ambient temperature in °C (°F)
Ambient temperature to process temperature dependency
(high temperature version)
70 ºC
(158 ºF)
0 ºC
(32 ºF)
-40 ºC
(-40 ºF)
-40 ºC
(-40 ºF)
-20 ºC
(-4 ºF)
0 ºC
20 ºC
40 ºC
60 ºC
80 ºC 100 ºC 120 ºC 140 ºC 150 ºC
(32 ºF) (68 ºF) (104 ºF) (140 ºF) (176 ºF) (212 ºF) (248 ºF) (284 ºF) (302 ºF)
Process temperature in °C (°F)
SITRANS LVL100 Ambient Temperature/Process Temperature derating curves
Siemens FI 01 · 2015
4/85
© Siemens AG 2014
Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL100
■ Dimensional drawings
SITRANS LVL100 (standard)
SITRANS LVL100 (extended high temperature)
{™Œˆ‹GnG½ A
(DIN ISO 228/1),
½ NPT
(valve plug ISO 4400)
{™Œˆ‹GnG¾“, G 1“ A
(DIN ISO 228/1) ,
¾” NPT or 1” NPT
(valve plug ISO 4400)
36 (1.42)
Tri-clamp (valve plug DIN 43650)
Thread G ¾” A, G 1“ A
(DIN ISO 228/1),
¾” NPT or 1” NPT
(valve plug DIN 43650)
36 (1.42)
27 (1.06)
27 (1.06)
35 (1.38)
4
32
(1.26)
G ¾“ A,
¾“ NPT
G 1“ A,
1“ NPT
Ø 21.3
(0.84)
L
40 (1.57)
Ø 31.7
(1.25)
156 (6.14)
158 (6.22)
Ø 31.7
(1.25)
Ø 31.7
(1.25)
32
G ¾“ A,
¾“ NPT
G 1“ A,
1“ NPT
Ø 21.3 (0.84)
32 (1.26)
G ½“ A,
½“ NPT
Ø 17
(0.67)
L
38 (1.5)
Switching
point
~ 101 (3.98)
~ 88 (3.46)
35 (1.38)
L
L
40 (1.57)
Switching
point
Switching
point
13 (0.51)
11 (0.43)
13 (0.51)
L=
Length with G ¾” A, ¾” NPT: 66 (2.6)
Length with G 1“ A, 1” NPT: 69 (2.7)
L=
Length with G ½” A, ½” NPT: 62 (2.4)
L=
Length with G ¾” A, ¾” NPT: 66 (2.6)
Length with G 1“ A, 1” NPT: 69 (2.7)
Length with Tri-clamp: 53 (2.1)
SITRANS LVL100 (extended, high temperature)
SITRANS LVL100 (standard with M12 connector)
SMS 1145
(valve plug DIN 43650)
Bolting DIN 11851
(valve plug DIN 43650)
10 (0.39)
10 (0.39)
Ø 21.3 (0.84)
40(1.57)
Switching
point
13 (0.51)
L=
Length with G ¾” A, ¾” NPT: 66 (2.6)
Length with G 1“ A, 1” NPT: 69 (2.7)
SITRANS LVL100, dimensions in mm (inch)
4/86
Siemens FI 01 · 2015
65 (1.26)
L
17 (0.67)
Switching
point
XXGOWU[ZP
L=
Length with G ½” A, ½” NPT: 62 (2.4)
~ 115 (4.53)
G½ A,
½“ NPT
38
(1.5)
G ¾“ A, ¾“ NPT
G 1“ A, 1“ NPT
130 (5.14)
158 (6.22)
32
SW 32
(1.26)
40 (1.57)
Ø 31.7
(1.25)
Ø 31.7
(1.25)
~ 105 (4.13)
M12 x 1
M12 x 1
L
L
Switching
point
13 (0.51)
L=
Length with bolting: 53 (2.1)
Length with SMS 1145: 53 (2)
© Siemens AG 2014
Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL100
■ Schematics
Transistor PNP (M12 x 1 plug connection)
1
Transistor PNP (with valve plug DIN 43650)
2
1
Max.
2
4
2
1
2
Max.
Min.
3
2
Min.
1
2
1
4
3
4
3
4
RL
RL
RL
2
1
3
3
3
RL
10 ... 55 V DC
10 ... 55 V DC
10 ... 55 V DC
PA (Potential equalization)
10 ... 55 V DC
PA
Contactless electronic switch (valve plug DIN 43650)
Min.
Max.
2
1
2
1
3
3
RL
RL
L1
N
PE (protective ground)
L1
N
PE
SITRANS LVL100, connections
Siemens FI 01 · 2015
4/87
© Siemens AG 2014
Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL200
■ Overview
■ Configuration
Marked with screwed version on top,
with flange versions directed to the
flange holes
Horizontal mounting
Switching point
(recommended
mounting position,
particularly for
adhesive applications)
Vertical mounting
4
Switching point
with lower
density
SITRANS LVL200 is a standard vibrating level switch for material
detection in liquid and slurry applications such as overflow, high,
low, and demand applications, as well as pump protection.
For use in SIL-2 applications.
■ Benefits
Switching point
[approx.
13 (0.51)]
Switching point
with higher
density
• Proven vibrating level switch technology for liquids
• Compact insertion length of 40 mm (1.57 inch) for confined
space applications
• Fault monitoring for corrosion, loss of vibration or line break to
the piezo drive
• Functional Safety (SIL 2). Device suitable for use in accordance with IEC 61508 and IEC 61511
• Hygienic process connections
■ Application
Switching point
[approx.
27 (1.06)]
Mount away from filling
openings or agitators.
SITRANS LVL200 is a level switch designed for industrial use in
all areas of process technology and can be used with liquids
and slurries. With a tuning fork insertion length of only 40 mm
(1.57 inch), SITRANS LVL200 can be mounted in small pipes
and applications with confined space. The LVL200 can be used
to measure products with a minimum density of > 0.5 g/cm³
(0.018 lb/in³). The LVL200 can be used in difficult conditions
including turbulence, air bubbles, foam generation, buildup,
or external vibration.
SITRANS LVL200 continuously monitors faults via frequency
evaluation, providing early detection of strong corrosion or damage on the tuning fork, loss of vibration, or a line break to the
piezo drive.
The tuning fork is piezoelectrically energized and vibrates at its
mechanical resonance frequency of approximately 1 200 Hz.
The vibration frequency changes when the tuning fork is covered by the medium. This change is detected by the integrated
oscillator and converted into a switching command. The integrated electronics evaluate the level signal and output a switching signal, directly operating connected devices.
• Key Applications: For use in liquids and slurries, for level
measurement, overfill, and dry run protection
Moisture protection
NOTE:
Welded socket for flush mount optional
Ensure cable gland
faces downward to
avoid water ingress.
SITRANS LVL200 installation, dimensions in mm (inch)
4/88
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL200
■ Technical specifications
Mode of operation
Measuring principle
Vibrating point level switch
Degree of protection
Conduit entry
Input
Measured variable
High and low and demand
(via mode switch)
Output
Output options
Measuring Accuracy
Repeatability
Hysteresis
Switching delay
Frequency
• Relay output (DPDT),
2 floating SPDTs
• Contactless electronic switch
• 2 wire Namur signal output
0.1 mm (0.004 inch)
Approx. 2 mm (0.08 inch)
with vertical installation
Approx. 500 ms (on/off)
Approx. 1 200 Hz
Indoor/outdoor
Ambient conditions
• Ambient temperature
• Installation category
• Pollution degree
-40 ... +70 °C (-40 ... +158 °F)
III
2
• Tuning fork
• Extension tube [ø 21.3 mm
(0.839 inch)]
• Process connection: threaded
• Process connection: flange
• Process seal
Process connection
• Pipe thread, cylindrical (ISO 228 T1)
• Pipe thread, tapered
• Flanges
• Hygienic fittings
20 ... 253 V AC, 50/60 Hz,
20 ... 72 V DC [at U>60 V DC
20 ... 253 V AC, 50/60 Hz,
20 ... 253 V DC
4
• 2 wire NAMUR
Installation conditions
• Location
Design
Material
• Enclosure
Approx. 0.8 ... 4 kg
(0.18 ... 8.82 lb)
Approx 920 g/m
(10 oz/ft)
Power supply
Supply voltage
• Relay DPDT
• Contactless
Rated operating conditions
Medium conditions
• Temperature
- LVL200S Standard
- LVL200S High temperature option
- LVL200E Standard: with
316L/Hastelloy
- LVL200E High temperature option:
with 316L/Hastelloy
• Pressure (vessel)
• Density
Weight
• Device weight
(dependent on process fitting)
• Tube extension
(extended version)
Type 4X/NEMA 4X/IP66/IP67
• 1 x M20x1.5 (cable: ø5 ... 9 mm),
1 x blind stopper M20x1.5; attached
1 x M20x1.5 cable entry
• 1 x ½" NPT cable entry,
1 x blind stopper ½" NPT,
1 x ½" NPT cable entry
• 1x M12x1; 1 x blind stopper
M20x1.5
Operating voltage (characteristics
IEC 60947-5-6, approx. 8.2 V
according to standard) for connection Off-load voltage Uo approx. 8.2 V
to an amplifier according to NAMUR Short-circuit current IU
approx. 8.2 mA
Power consumption
• Relay DPDT
• Contactless
-50 ... +150 °C (-58 ... +302 °F)
-50 ... +250 °C (-58 ... +482 °F)
-50 ... +150 °C (-58 ... +302 °F)
-50 ... +250 °C (-58 ... +482 °F)
-1 ... 64 bar g (-14.5 ... 928 psi g)
0.7 ... 2.5 g/cm³ (0.025 ... 0.09 lb/in³);
0.5 ... 2.5 g/cm³ (0.018 ... 0.09 lb/in³)
by switching over
Aluminum die-cast AISi10Mg,
powder-coated, basis: Polyester
Stainless steel housing, electropolished 316L
316L (1.4404 or 1.4435), Hastelloy
316L (1.4404 or 1.4435), Hastelloy
316L (1.4404 or 1.4435), Hastelloy
316L (1.4404 or 1.4435), 316L with
Hastelloy, ECTFE, or PFA coating
Klingersil C-4400
G ¾" A, G 1" A
¾" NPT, 1" NPT, 1½" NPT
DIN from DN25, ANSI from 1"
Bolting DN 40 PN 40, 1, 1½, 2,
2½" Tri-Clamp PN 10, conus
DN 25 PN 40, Tuchenhagen Varivent
DN 50 PN 10, SMS
• 2 wire Namur
Certificates and approvals
1 ... 8 VA (AC), approx. 1.3 W (DC)
1 ... 8 VA (AC), approx. 1.3 W (DC)
Domestic current requirement
approx. 3 mA (via load circuit)
Load current
- Min. 10 mA
- Max. 400 mA [with I > 300 mA
the ambient temperature can
be max. 60 °C (140 °F)]
- Max. 4 A up to 40 ms
(not WHG specified)
Current consumption
- Falling characteristics  2.6 mA
uncovered/ 0.6 mA covered
-  0.6 mA uncovered/ 2.6 mA
covered
- Failure message  0.6 mA
• CE, CSA
• Overfill Protection WHG
and VLAREM II
• FM (Non-Incendive) Class I, Div. 2,
Groups A, B, C, D
• FM (Explosion-Proof) Class I, Div. 1,
Groups A, B, C, D; (Dust IgnitionProof) Class II, III, Div. 1,
Groups E, F, G1)
• IECEx d IIC T6...T2 Ga/Gb EHEDG
• ATEX II 1/2G, 2G EEx d IIC T6
• ATEX II 1G, 1/2G, 2G EEx ia IIC T6
Shipping approvals
• BR-Ex d IIC T6...T2
• FDA, 3A, Ehedge
• SIL/IEC61508 Declaration of Conformity [SIL-2 (min/max detection)]
Siemens FI 01 · 2015
4/89
© Siemens AG 2014
Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL200
Selection and Ordering data
Article No.
Selection and Ordering data
Article No.
SITRANS LVL200, Standard
Compact vibrating level switch for material detection in liquid and slurry applications such as overflow, high, low, and demand applications, as well as
pump protection. For use in SIL-2 and hazardous
applications.
7ML5746-
SITRANS LVL200, Standard
Compact vibrating level switch for material detection in liquid and slurry applications such as overflow, high, low, and demand applications, as well as
pump protection. For use in SIL-2 and hazardous
applications.
7ML5746-
7 7 7 77 - 77 A 0
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Electronics
Contactless electronic switch 20...250 V AC/DC
¢ 1
Double relay (DPDT) 20 ... 72 V DC/20 ... 250 V AC ¢ 2
¢ 4
NAMUR signal1)
Approvals
Without approvals
Overfill protection (WHG)
ATEX II 1G, 1/2G, 2G EEx ia IIC T6 + WHG 2)
4
3)
ATEX II 1/2G, 2G EEx d IIC T6 + WHG
ATEX II 1G, 1/2G, 2G EEx ia IIC T6 + shipping
approvals2)
ATEX II 1/2G, 2G EEx d IIC T6 + shipping
approvals3)
¢
¢
¢
A
B
C
¢
¢
D
E
¢
F
ATEX II 1G, 1/2G, 2G EEx ia IIC T6 + ATEX II 1/2 D ¢
IP6X T2)
IECEx Ex ia IIC T62)
¢
Shipping approvals
¢
G
FM (IS) Class I, II, III, Div. 1, Groups A, B, C, D, E, F, ¢
G 2)4)
¢
FM (XP) Class I, Div. 1, Groups A, B, C, D; (DIP)
Class II, III, Div. 1, Groups E, F, G3)4)
FM (NI) Class I, Div. 2, Groups A, B, C, D4)
¢
N
Q
IECEx d IIC T6...T2 Ga/Gb
¢
CSA(XP)CL I, II, III Div. 1,Groups A,,B, C, D, E, F, G ¢
CSA(NI)CL I, II, III, Div. 2, Groups A, B, C, D, E, F, G¢
R
S
T
¢
BR-Ex d IIC T6...T2
CSA(IS)CL I, II, III Div. 1, Groups A, B, C, D, E, F, G ¢
U
V
Process connection
Thread G¾" A, PN 64/316L
Thread G¾" A, PN 64/316L Ra < 0.8 µm
Thread ¾" NPT, PN 64/316L
Thread ¾" NPT, PN 64/316L Ra < 0.8 µm
Thread ¾" NPT, PN 64/Monel
Thread G¾" A, PN 64/Hastelloy
Thread ¾" NPT, PN 64/Hastelloy
Thread G1" A, PN 64/316L
Thread G1" A, PN 64/316L ECTFE coated
MB19825)
Thread G1" A, PN 64/316L PFA coated5)
Thread G1" A, PN 64/Monel
Thread G1" A, PN 64 / 316L Ra<0.8µm
Thread G1" A, PN 64/316L Ra < 0.8 µm
¢
¢
¢
¢
¢
¢
¢
¢
¢
¢
Thread 1" NPT, PN 64/316L5)
Thread 1" NPT, PN 64/316L ECTFE
coatedMB19825)
Thread 1" NPT, PN 64/316L PFA-coated
P
A00
A01
A02
A03
A04
A05
A06
A07
A08
A10
A11
A12
A13
A14
A15
A16
¢
¢
A17
A18
Thread G1" A, PN 64/Hastelloy
Thread G1½" A, PN 64/316L
Thread G1½" A, PN 64/316L Ra<0,8µm
¢
¢
¢
A20
A21
A22
Thread G1½" A, PN 64/Hastelloy
Thread 1" NPT, PN 64/Hastelloy
Thread 1½" NPT, PN 64/316L
¢
¢
¢
A23
A24
A25
Thread 1½" NPT, PN 64/316L Ra<0,8µm
Thread 1½" NPT, PN 64/Hastelloy
Thread G2" A, PN 64/316L
¢
¢
¢
A26
A27
A28
Siemens FI 01 · 2015
¢
¢
¢
A30
A31
A32
Conus DN 25, PN 40/ECTFE (ZB3033)5)
Conus M52, PN 40/316L
Conus M52, PN 40/316L Ra < 0.3 µm
¢
¢
A33
A34
A35
Conus M52, PN 40/316L Ra < 0.8 µm
Tri-Clamp 1", PN 16/316L Ra < 0.3 µm
¢
¢
A36
A37
Tri-Clamp 1", PN 16/Hastelloy
Tri-Clamp 1", PN 16/316L Ra < 0.8 µm
Tri-Clamp 1½", PN 16/316L Ra < 0.3 µm
¢
¢
¢
A38
A40
A4 1
Tri-Clamp 1½", PN 16/Hastelloy
¢
¢
A42
¢
¢
A43
A44
A45
¢
¢
¢
A46
A47
A48
Tri-Clamp 3", PN 10/316L Ra < 0.3 µm
¢
Tri-Clamp 3", PN 10/316L Ra < 0.8 µm
¢
Bolting DN 32, PN 40 DIN11851/316L Ra < 0.3 µm ¢
A50
A51
A52
Bolting DN 32, PN 40 DIN11851/316L Ra < 0.8 µm ¢
Bolting DN 25, PN 40 DIN11851/316L Ra < 0.3 µm ¢
Bolting DN 25, PN 40 DIN11851/316L Ra < 0.8 µm ¢
A53
A54
A55
Bolting DN 40, PN 40 DIN11851/316L Ra < 0.3 µm ¢
Bolting DN 40, PN 40 DIN11851/316L Ra < 0.8 µm ¢
¢
Bolting DN 40, PN 40 DIN11864-1 A/316L
Ra < 0.8 µm ZB3052
A56
A57
A58
Bolting DN 50, PN 25 DIN11851/316L Ra < 0.3 µm ¢
Bolting DN 50, PN 25 DIN11851/316L Ra < 0.8 µm ¢
Bolting DN 50, PN 25 DIN11864-1 A/316L
¢
Ra < 0.8 µm ZB3052
A60
A61
A62
Hygienic w. compr. nut F40, PN 25/316L
Hygienic w. compr. nut F40, PN 25/316L
Ra < 0.3 µm
Hygienic w. compr. nut F40, PN 25/316L
Ra < 0.8 µm
¢
¢
¢
¢
A63
A64
Varivent N50-40/316L Ra < 0.3 µm
Varivent N50-40/316L Ra < 0.8 µm
Varivent N125/100/316L Ra < 0.8 µm
¢
¢
¢
A66
A67
A68
DRD flange, PN 40/316L ZB3007
SMS DN 38/316L Ra < 0.8 µm5)
SMS DN 51, PN 6/316L Ra < 0.8 µm5)
¢
¢
¢
A70
A71
A72
Tri-Clamp 2", PN 16/316L Ra < 0.8 µm
Tri-Clamp 2½", PN 10/316L Ra < 0.3 µm
Tri-Clamp 2½", PN 10/316L Ra < 0.8 µm
Thread 1" NPT, PN 64/Monel
Thread 1" NPT, PN 64/316L Ra < 0.8 µm
4/90
Thread M27x1.5, PN 64/316L
Conus DN 25, PN 40/316L Ra < 0.3 µm
Conus DN 25, PN 40/316L Ra < 0.8 µm
Tri-Clamp 1½", PN 16/316L Ra < 0.8 µm
Tri-Clamp 2", PN 16/316L Ra < 0.3 µm
Tri-Clamp 2", PN 16/Hastelloy
H
K
7 7 7 77 - 77 A 0
A65
Swagelok VCR screwing ZG2579, PN 64/316L
Neumo biocontrol size 25, PN 16/316L Ra < 0.8 µm
Neumo biocontrol size 50, PN 16/316L Ra < 0.8 µm5)
A73
A74
A75
Neumo biocontrol size 65, PN 16/316L Ra < 0.8 µm
Neumo biocontrol size 80, PN 16/316L Ra < 0.8 µm
SÜDMO DN 50, PN 10/316L Ra<0,8µm
A76
A77
A78
Small flange DN 25, PN 1.5 DIN 28403/316L pol.
Ra < 0.8 µm
Small flange DN 40, PN 1.5 DIN 28403/316L pol.
Ra < 0.8 µm
Ingold connection, PN 16/316L Ra < 0.8 µm
A80
Ingold connection, PN 16/Hastelloy
Terminal DN 33.7 PN 40 DIN11864-3-A-/316L BN2
Ra < 0.8 µm5)
Hygienic fl. DN 50 PN 16 DIN11864-2-A-/316L
Ra < 0.8 µm
A83
A84
A81
A82
A85
© Siemens AG 2014
Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL200
Selection and Ordering data
Article No.
Selection and Ordering data
Article No.
SITRANS LVL200, Standard
Compact vibrating level switch for material detection in liquid and slurry applications such as overflow, high, low, and demand applications, as well as
pump protection. For use in SIL-2 and hazardous
applications.
7ML5746-
SITRANS LVL200, Standard
Compact vibrating level switch for material detection in liquid and slurry applications such as overflow, high, low, and demand applications, as well as
pump protection. For use in SIL-2 and hazardous
applications.
7ML5746-
7 7 7 77 - 77 A 0
7 7 7 77 - 77 A 0
Flange DN 80, PN 40 Form C, DIN 2501/PFA5)
Flange DN 80, PN 40 Form C, DIN 2501/
Enamelled6)
Flange DN 80, PN 40 Form F, DIN 2501/316L
B56
B57
Flange DN 80, PN 40 Form N, DIN 2501/316L
Flange DN 100, PN 16 Form C, DIN 2501/316L
Flange DN 100, PN 16 Form C, DIN 2501/Hastelloy
B60
B62
B63
Flange DN 100, PN 16 Form C, DIN 2501/ECTFE5)
Flange DN 100, PN 16 Form C, DIN 2501/PFA5)
Flange DN 100, PN 16 Form C, DIN 2501/
Enamelled6)
B64
B65
B66
Flange DN 100, PN 16 Form D, DIN 2501/316L
B67
Flange DN 100, PN 16 Form F, DIN 2501/316L
Flange DN 100, PN 16 Form N, DIN 2501/316L
Flange DN 100, PN 40 Form C, DIN 2501/316L
B68
B70
B71
B13
B14
B15
Flange DN 100, PN 40 Form C, DIN 2501/ECTFE5)
Flange DN 100, PN 40 Form C, DIN 2501/PFA5)
Flange DN 100, PN 40 Form C, DIN 2501/
Enamelled6)
B72
B73
B74
Flange DN 40, PN 40 Form C, DIN 2501/Hastelloy
Flange DN 40, PN 40 Form C, DIN 2501/ECTFE5)
Flange DN 40, PN 40 Form C, DIN 2501/PFA5)
B16
B17
B18
Flange DN 100, PN 40 Form F, DIN 2501/316L
Flange DN 100, PN 40 Form N, DIN 2501/316L
Flange DN 100, PN 40 V13, DIN 2501/316L
B75
B76
B77
Flange DN 40, PN 40 Form C, DIN 2501/
Enamelled6)
Flange DN 40, PN 40 Form F, DIN 2501/316L
Flange DN 40, PN 40 Form N, DIN 2501/316L
B20
Flange DN 100, PN 64 Form E, DIN 2501/316L
Flange DN 100, PN 100 Form E, DIN 2501/316L
Flange DN 100, PN 100 Form L, DIN 2501/316L
B78
B80
B81
Flange DN 40, PN 40 Form E, DIN 2501/316L
Flange DN 40, PN 40 V13, DIN 2501/316L
Flange DN 50, PN 40 Form C, DIN 2501/316L
B23
B24
B25
Flange DN 125, PN 16 Form F, DIN 2501/316L
Flange DN 125, PN 40 Form C, DIN 2501/316L
Flange DN 125, PN 40 Form N, DIN 2512/ 316L
B82
B83
B84
Flange DN 50, PN 40 Form C, DIN 2501/Hastelloy
Flange DN 50, PN 40 Form C, DIN 2501/ECTFE5)
Flange DN 50, PN 40 Form C, DIN 2501/
ECTFE (ZB3108)5)
B26
B27
B28
Flange DN 150, PN 16 Form C, DIN 2501/316L
Flange DN 150, PN 16 Form C, DIN 2501/Hastelloy
Flange DN 150, PN 16 Form C, DIN 2501/ECTFE5)
B85
B86
B87
Flange DN 50, PN 40 Form C, DIN 2501/PFA5)
Flange DN 50, PN 40 Form D, DIN 2501/316L
Flange DN 50, PN 40 Form D, DIN 2501/Hastelloy
B30
B31
B32
Flange DN 150, PN 16 Form C, DIN 2501/PFA5)
Flange DN 150, PN 16 Form D, DIN 2501/316L
Flange DN 150, PN 40 Form C, DIN 2501/316L
B88
C00
C01
Flange DN 50, PN 40 Form F, DIN 2501/316L
Flange DN 50, PN 40 Form N, DIN 2501/316L
Flange DN 50, PN 40 Form N, DIN 2501/Hastelloy
B33
B34
B35
Flange DN 150, PN 40 Form C, DIN 2501/Hastelloy
Flange DN 150, PN 40 Form F, DIN 2501/316L
Flange DN 150, PN 40 Form N, DIN 2512/316L
C02
C03
C04
Flange DN 50, PN 40 Form E, DIN 2501/316L
Flange DN 50, PN 40 V13, DIN 2501/316L
Flange DN 50, PN 40 R13, DIN 2501/316L
B36
B37
B38
Flange DN 200, PN 10 Form C, DIN 2501/ECTFE5)
Flange DN 200, PN 16 Form C, DIN 2501/316L
Flange DN 25, PN 40 Form B1, EN 1092-1/316L
C05
C06
C07
Flange DN 50, PN 64 Form F, DIN 2501/316L
Flange DN 50, PN 64 Form N, DIN 2501/Hastelloy
Flange DN 50, PN 64 Form C, DIN 2501/316L
B40
B41
B42
Flange DN 25, PN 40 Form B1, EN 1092-1/Hastelloy
Flange DN 25, PN 40 Form B1, EN/ 316L/ PFA5)
Flange DN 25, PN 40 Form B1, EN 1092-1/
Enamelled 6)
C08
C10
C11
Flange DN 50, PN 64 Form L, DIN 2501/316L
Flange DN 50, PN 100 Form E, DIN 2501/316L
Flange DN 50, PN 100 Form L, DIN 2501/316L
B43
B44
B45
Flange DN 25, PN 40 Form B2, EN 1092-1/316L
Flange DN 25, PN 40 Form F, EN 1092-1/316L
Flange DN 25, PN 63 Form B1, EN 1092-1/316L
C12
C13
C14
Flange DN 65, PN 40 Form C, DIN 2501/316L
Flange DN 65, PN 40 Form C, DIN 2501/Hastelloy
Flange DN 65, PN 40 Form C, DIN 2501/ECTFE5)
B46
B47
B48
Flange DN 25, PN 100 Form B2, EN 1092-1/316L
Flange DN 40, PN 40 Form B1, EN/ 316L
Flange DN 40, PN 40 Form B1, EN 1092-1/PFA5)
C15
C16
C17
Flange DN 65, PN 40 Form C, DIN 2501/PFA5)
Flange DN 65, PN 40 Form F, DIN 2501/316L
Flange DN 65, PN 64 Form E, DIN 2501/316L
B50
B51
B52
Flange DN 40, PN 40 Form B2, EN/316L
Flange DN 50, PN 40 Form B1, EN/316L
Flange DN 50, PN 40 Form B1, EN 1092-1/
Hastelloy
C18
C20
C21
B53
B54
B55
Flange DN 50, PN 40 Form B1, EN 1092-1/
Monel ZB2977
Flange DN 50, PN 40 Form B1, EN 1092-1/ECTFE5)
Flange DN 50, PN 40 Form B1, EN/ 316L/PFA5)
C22
Flange DN 80, PN 40 Form C, DIN 2501/316L
Flange DN 80, PN 40 Form C, DIN 2501/ Hastelloy
Flange DN 80, PN 40 Form C, DIN 2501/ECTFE5)
Flange DN 25, PN 6 Form C, DIN 2501/316L
Flange DN 25, PN 6 Form C, DIN 2501/PFA5)
Flange DN 25, PN 40 Form C, DIN 2501/316L
A86
A87
A88
Flange DN 25, PN 40 Form C, DIN 2501/Hastelloy
Flange DN 25, PN 40 Form C, DIN 2501/ECTFE5)
Flange DN 25, PN 40 Form C, DIN 2501/PFA5)
B00
B01
B02
Flange DN 25, PN 40 Form C, DIN 2501/Enamelled
Flange DN 25, PN 40 Form D, DIN 2501/316L
Flange DN 25, PN 40 Form F, DIN 2501/316L
B03
B04
B05
Flange DN 25, PN 40 Form N, DIN 2501/316L
Flange DN 25, PN 40 Form N, DIN 2501/Hastelloy
Flange DN 25, PN 40 Form N, DIN 2501/Monel
solid
B06
B07
B08
Flange DN 25, PN 40 V13, DIN 2501/316L
Flange DN 32, PN 40 Form C, DIN 2501/316L
Flange DN 32, PN 40 Form C, DIN 2501/ECTFE5)
B10
B11
B12
Flange DN 40, PN 6 Form C, DIN 2501/316L
Flange DN 40, PN 6 Form C, DIN 2501/ECTFE5)
Flange DN 40, PN 40 Form C, DIN 2501/316L
B21
B22
B58
4
C23
C24
Siemens FI 01 · 2015
4/91
© Siemens AG 2014
Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL200
4
Selection and Ordering data
Article No.
Selection and Ordering data
Article No.
SITRANS LVL200, Standard
Compact vibrating level switch for material detection in liquid and slurry applications such as overflow, high, low, and demand applications, as well as
pump protection. For use in SIL-2 and hazardous
applications.
7ML5746-
SITRANS LVL200, Standard
Compact vibrating level switch for material detection in liquid and slurry applications such as overflow, high, low, and demand applications, as well as
pump protection. For use in SIL-2 and hazardous
applications.
7ML5746-
7 7 7 77 - 77 A 0
7 7 7 77 - 77 A 0
Flange DN 50, PN 40 Form B1, EN 1092-1/
Enamelled6)
Flange DN 50, PN 40 Form C, EN 1092-1/316L
Flange DN 50, PN 40 Form D, EN/316L
C25
Flange 2" 300 lb RF, ANSI B16.5/316L
Flange 2" 300 lb RF, ANSI B16.5/Hastelloy
C82
C83
C26
C27
Flange DN 50, PN 40 Form D, EN 1092-1/Hastelloy
Flange DN 50, PN 40 Form B2, EN 1092-1/316L
Flange DN 50, PN 40 Form E, EN 1092-1/316L
C28
C30
C31
Flange 2" 300 lb RF, ANSI B16.5/ECTFE5)
Flange 2" 300 lb RF, ANSI B16.5/PFA5)
Flange 2" 300 lb RF, ANSI B16.5 Enamelled6)
C85
C86
C87
Flange DN 80, PN 40 Form B1, EN 1092-1/316L
Flange DN 80, PN 40 Form B1, EN 1092-1/Hastelloy
Flange DN 80, PN 40 Form B1, EN 1092-1/ECTFE5)
C32
C33
C34
Flange 2" 300 lb RJF, ANSI B16.5/316L
Flange 2" 300 lb ST, ANSI B16.5/316L
Flange 2" 300 lb LG (large groove),
ANSI B16.5/316L
C88
D00
D01
Flange DN 80, PN 40 Form B1, EN 1092-1/
Enamelled6)
Flange DN 80, PN 40 Form B2, EN 1092-1/316L
Flange DN 100, PN 16 Form B1, EN 1092-1/316L
C35
Flange 2" 300 lb LT, ANSI B16.5/316L
Flange 2" 600 lb RF, ANSI B16.5/316L
Flange 2" 600 lb RF, ANSI B16.5/Monel ZB2977
D02
D03
D04
Flange DN 100, PN 16 Form B1, EN 1092-1/
Hastelloy
C38
Flange 2" 600 lb RF, ANSI B16.5/ECTFE5)
Flange 2" 600 lb RJF, ANSI B16.5/316L
Flange 2" 600 lb LG, ANSI B16.5/316L
D05
D06
D07
Flange DN 100, PN 16 Form B1, EN 1092-1/
Enamelled6)
Flange DN 100, PN 40 Form B1, EN 1092-1/316L
Flange DN 100, PN 40 Form B1, EN 1092-1/
Enamelled6)
C40
Flange 2" 900 lb RJF, ANSI B16.5/316L
Flange 2½" 150 lb RF, ANSI B16.5/316L
Flange 2½" 300 lb RF, ANSI B16.5/316L
D08
D10
D11
Flange DN 100, PN 40 Form C, EN 1092-1/316L
Flange DN 100, PN 63 Form B2, EN 1092-1/316L
Flange DN 150, PN 16 Form B1, EN 1092-1/316L
C43
C44
C45
Flange 3" 150 lb RF, ANSI B16.5/316L
Flange 3" 150 lb RF, ANSI B16.5/Hastelloy
Flange 3" 150 lb RF, ANSI B16.5/ECTFE5)
D12
D13
D14
Flange 3" 150 lb RF, ANSI B16.5/PFA5)
Flange 3" 150 lb RF, ANSI B16.5/Enamelled6)
D15
D16
Flange DN 150, PN 16 Form B1, EN 1092-1/PFA5)
Flange DN 150, PN 40 Form B1, EN 1092-1/316L
C46
C47
Flange 3" 150 lb FF, ANSI B16.5/316L
D17
Flange DN 150, PN 40 Form B1, EN 1092-1/
ECTFE5)
Flange DN 150, PN 40 Form B2, EN 1092-1/316L
Flange 1" 150 lb ANSI B16.5/316L
C48
Flange 3" 150 lb FF, ANSI B16.5/ECTFE5)
Flange 3" 150 lb FF, ANSI B16.5/PFA5)
Flange 3" 300 lb RF, ANSI B16.5/316L
D18
D20
D21
Flange 1" 150 lb RF, ANSI B16.5/Hastelloy
Flange 1" 150 lb RF, ANSI B16.5/Monel ZB2977
Flange 1" 150 lb RF, ANSI B16.5/ECTFE5)
C52
C53
C54
Flange 3" 300 lb RF, ANSI B16.5/Hastelloy
Flange 3" 300 lb RF, ANSI B16.5/ECTFE5)
Flange 3" 300 lb RF, ANSI B16.5/PFA5)
D22
D23
D24
Flange 1" 150 lb RF, ANSI B16.5/PFA5)
Flange 1" 150 lb RF, ANSI B16.5/Enamelled6)
Flange 1" 300 lb RF, ANSI B16.5/316L
C55
C56
C57
Flange 3" 300 lb RF, ANSI B16.5/Enamelled6)
Flange 3" 600 lb RF, ANSI B16.5/316L
Flange 3½" 150 lb RF, ANSI B16.5/316L
D25
D26
D27
Flange 1" 300 lb RF, ANSI B16.5/ECTFE5)
Flange 1" 600 lb RF, ANSI B16.5/316L
Flange 1½" 150 lb RF, ANSI B16.5/316L
C58
C60
C61
Flange 3½" 150 lb RF, ANSI B16.5/ECTFE5)
Flange 4" 150 lb RF, ANSI B16.5/316L
Flange 4" 150 lb RF, ANSI B16.5/Hastelloy
D28
D30
D31
Flange 1½" 150 lb RF, ANSI B16.5/Hastelloy
Flange 1½" 150 lb RF, ANSI B16.5/ECTFE5)
Flange 1½" 150 lb RF, ANSI B16.5/PFA5)
C62
C63
C64
Flange 4" 150 lb RF, ANSI B16.5/ECTFE5)
Flange 4" 150 lb RF, ANSI B16.5/PFA5)
Flange 4" 150 lb RF, ANSI B16.5/Enamelled6)
D32
D33
D34
Flange 1½" 150 lb RF, ANSI B16.5 Enamelled6)
Flange 1½" 150 lb FF, ANSI B16.5/ECTFE5)
Flange 1½" 300 lb RF, ANSI B16.5/316L
C65
C66
C67
Flange 4" 150 lb LT, ANSI B16.5/316L
Flange 4" 300 lb RF, ANSI B16.5/316L
Flange 4" 300 lb RF, ANSI B16.5/Hastelloy
D35
D36
D37
Flange 1½" 300 lb RF, ANSI B16.5/Monel ZB2977
Flange 1½" 300 lb RF, ANSI B16.5/ECTFE6)
Flange 1½" 600 lb RF, ANSI B16.5/316L
C68
C70
C71
Flange 4" 300 lb RF, ANSI B16.5/ECTFE5)
Flange 4" 300 lb RJF, ANSI B16.5/316L
Flange 4" 300 lb LG, ANSI B16.5/316L
D38
D40
D41
Flange 2" 150 lb RF, ANSI B16.5/316L
Flange 2" 150 lb RF, ANSI B16.5/Hastelloy
Flange 2" 150 lb RF, ANSI B16.5/Monel ZB2977
C72
C73
C74
Flange 4" 300 lb LT, ANSI B16.5/316L
Flange 4" 600 lb RF, ANSI B16.5/316L
Flange 4" 600 lb RJF, ANSI B16.5/316L
D42
D43
D44
Flange 2" 150 lb RF, ANSI B16.5/ECTFE5)
Flange 2" 150 lb RF, ANSI B16.5/PFA5)
Flange 2" 150 lb RF, ANSI B16.5/Enamelled6)
C75
C76
C77
Flange 6" 150 lb RF, ANSI B16.5/316L
Flange 6" 150 lb RF, ANSI B16.5/Hastelloy
Flange 6" 150 lb RF, ANSI B16.5/ECTFE5)
D45
D46
D47
Flange 2" 150 lb FF, ANSI B16.5/316L
Flange 2" 150 lb FF, ANSI B16.5/ECTF5)
Flange 2" 150 lb SG (small groove),
ANSI B16.5/316L
C78
C80
C81
Flange 6" 150 lb RF, ANSI B16.5/PFA5)
Flange 6" 150 lb RJF, ANSI B16.5/316L
Flange 6" 300 lb RF, ANSI B16.5/316L
D48
D50
D51
Flange 8" 150 lb RF, ANSI B16.5/316L
Flange 8" 150 lb RF, ANSI B16.5/ECTFE5)
Flange 1" BS.10 Table E/316L
D52
D53
D54
4/92
Siemens FI 01 · 2015
C36
C37
C41
C42
C50
C51
© Siemens AG 2014
Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL200
Selection and Ordering data
Article No.
Selection and Ordering data
Order code
SITRANS LVL200, Standard
Compact vibrating level switch for material detection in liquid and slurry applications such as overflow, high, low, and demand applications, as well as
pump protection. For use in SIL-2 and hazardous
applications.
7ML5746-
Functional Safety (SIL 2). Device suitable for use in
accordance with IEC 61508 and IEC 615111)
C20
Dye penetration test + 3.1 certificate/instrument1)
C13
X-ray test + 3.1 certificate/instrument1)
C14
Positive material identification test
+ 3.1 certificate/instrument1)
C16
Roughness test + 3.1 certificate/instrument1)
C18
7 7 7 77 - 77 A 0
E/PFA5)
D55
D56
D57
Flange 1" BS.10 Table
Flange 1½" BS.10 Table E/316L
Flange 3½" BS.10 Table E/316L
E/ECTFE5)
Flange 4" BS.10 Table
Flange DN 40 10K, JIS/316L
Flange DN 50 10K, JIS/316L
D58
D60
D61
Flange DN 80 10K, JIS/316L
Flange DN 100 10K, JIS/316L
D62
D63
Adapter/Process temperature
Without adapter/-50 ... +150 °C (-58 ... +302 °F)
With adapter/-50 ... +200 °C (-58 ... +392 °F)7)
With adapter/-50 .... +250 °C (-58 ... +482 °F)
With gas-tight leadthrough/-50 ... +150 °C
(-58 ... +302 °F)
With gas-tight leadthrough/-50 ... +250 °C
(-58 ... +482 °F)
Housing/ Cable entry
Aluminium IP66/IP67/M20x1.5
Aluminium IP66/IP67/½" NPT
316L stainless steel (electropolished)
IP66/IP67/M20X1.58)9)
316L stainless steel (electropolished)
IP66/IP67/½" NPT8)9)
1)
Pressure test + 3.1
¢
¢
¢
1
2
3
¢
4
¢
C31
Helium leak test + 3.1 certificate/instrument1)
C32
Ferrite measuring accuracy to DIN32514-1
+ 3.1 certificate/instrument1)
C60
Pressure test according to Norsok
+ 3.1 certificate/instrument1)
C61
Additional Operating Instructions
Article No.
LVL200 (DPDT Relay)
5
¢
¢
certificate/instrument1)
A
B
C
D
Available with Adapter/Process temperature options 1, 3, 4, and 5 only
• English
7ML1998-5KR01
• French
7ML1998-5KR11
• Spanish
7ML1998-5KR21
• German
7ML1998-5KR31
LVL200 (Contactless electronic switch)
• English
7ML1998-5KQ01
• French
7ML1998-5KQ11
• Spanish
7ML1998-5KQ21
• German
7ML1998-5KQ31
Electronics module LVL200 Relay
2)
Available with Electronics option 4 only
3)
Available with Adapter/Process temperature options 1 and 3 only
• English
7ML1998-5LS01
4)
Available with Housing/Cable entry option B only
• French
7ML1998-5LS11
5)
Available with Adapter/Process temperature options 1 and 4 only
6)
Available with Adapter/Process temperature options 1, 2, and 4 only
• Spanish
7ML1998-5LS21
• German
This device is shipped with the Siemens Milltronics
manual DVD containing the Operating Instructions
library.
7ML1998-5LS31
7)
Available with enamelled Process connection options only
8)
Available with Approval options A, B, C only
9)
Not available with SIL/IEC61508 Certificate of conformity
(SIL-2 min. and max. detection)
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Selection and Ordering data
Spare Parts and Accessories
Electronics module SITRANS LVL200 Relay
7ML1830-1NC
Electronics module SITRANS LVL200 Contactless
LVL200 Threaded Welded Socket
7ML1930-6AA
• G¾" A/316L with FKM Seal
7ML1930-1EE
• G1" A/316L with FKM Seal
7ML1930-1EF
• M27x1.5/316L with FKM Seal
7ML1930-1EG
• G¾" A/316L with EPDM Seal
7ML1930-1EH
• G1" A/316L with EPDM Seal
7ML1930-1EJ
• M27x1.5/316L with EPDM Seal
7ML1930-1EK
Order code
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
Cleaning including Certificate
(oil, grease, and silicone free)
W01
Identification Label (measurement loop) stainless
steel:
max. 16 characters add in plain text
Y17
Identification Label (measurement loop) Foil:
max. 16 characters add in plain text
Y18
Acceptance test certificate 3.1 NACE MR 0775 for
material EN102041)
D07
Acceptance test certificate 3.1 for instrument
EN102041)
C12
Acceptance test Certificate 2.2 for material
EN102041)
C15
1)
Listed Certificates are not available with all configurations, please contact
factory for more information
Siemens FI 01 · 2015
4/93
4
© Siemens AG 2014
Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL200
Selection and Ordering data
Article No.
Selection and Ordering data
Article No.
SITRANS LVL200, Rigid extension
Compact vibrating level switch for material detection in liquid applications such as overflow, high,
low, and demand applications, as well as pump
protection. For use in SIL-2 and hazardous applications.
7ML5747-
SITRANS LVL200, Rigid extension
Compact vibrating level switch for material detection in liquid applications such as overflow, high,
low, and demand applications, as well as pump
protection. For use in SIL-2 and hazardous applications.
7ML5747-
77 7 77 - 77 77
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Electronics
Contactless electronic switch 20...250 V AC/DC
Double relay (DPDT) 20 ... 72 V DC/20 ... 250 V AC
NAMUR signal1)
4
Approvals
Without approvals
Overfill protection (WHG)
ATEX II 1G, 1/2G, 2G EEx ia IIC T6 + WHG2)
1
2
4
A
B
C
7 7 7 77 - 77 7 7
Cyl. socket/316Ti/1.4581 ECTFE coated ZB29846)
Conus DN 25 PN 40/316L Ra < 0.3 µm
Conus DN 25 PN 40/316L Ra < 0.8 µm.
A31
A32
A33
Conus DN 25 PN 40/ECTFE (ZB3033)6)
Conus M52 PN 40/316L
Conus M52 PN 40/316L Ra < 0.3 µm
A34
A35
A36
Conus M52 PN 40/316L Ra < 0.8 µm
Tri-Clamp 1" PN 16/316L Ra < 0.3 µm
Tri-Clamp 1" PN 16/Hastelloy
A37
A38
A40
Tri-Clamp 1" PN 16/316L Ra < 0.8 µm
Tri-Clamp 1½" PN 16/316L Ra < 0.3 µm
Tri-Clamp 1½" PN 16/Hastelloy
A41
A42
A43
Tri-Clamp 1½" PN 16/316L Ra < 0.8 µm
Tri-Clamp 2" PN 16/316L Ra < 0.3 µm
Tri-Clamp 2" PN 16/Hastelloy
A44
A45
A46
Tri-Clamp 2" PN 16/316L Ra < 0.8 µm
Tri-Clamp 2½" PN 10/316L Ra < 0.3 µm
Tri-Clamp 2½" PN 10/316L Ra < 0.8 µm
A47
A48
A50
ATEX II 1/2G, 2G EEx d IIC T6 + WHG3)4)
ATEX II 1G, 1/2G, 2G EEx ia IIC T6 + shipping
approvals2)
ATEX II 1/2G, 2G EEx d IIC T6 + shipping
approvals3)4)
D
E
ATEX II 1G, 1/2G, 2G EEx ia IIC T6 + ATEX II 1/2D
IP6X T2)
IECEx Ex ia IIC T62)
Shipping approvals
G
FM (IS) Class I, II, III, Div. 1, Groups A, B, C, D, E, F, G 2)5)
FM (XP) Class I, Div. 1, Groups A, B, C, D; (DIP)
Class II, III, Div. 1, Groups E, F, G3)4)5)
N
P
Tri-Clamp 3" PN 10/316L Ra < 0.3 µm
Tri-Clamp 3" PN 10/316L Ra < 0.8 µm
Bolting DN 32 PN 40 DIN11851/316L Ra < 0.3 µm
A51
A52
A53
FM (NI) Class I, Div. 2, Groups A, B, C, D5)
IECEx d IIC T6...T2 Ga/Gb4)
CSA(XP)CL I,II,III Div. 1,Groups A, B, C, D, E, F,
G...T2 4) Ga/Gb
Q
R
S
Bolting DN 32 PN 40 DIN11851/316L Ra < 0.8 µm
Bolting DN 25 PN 40 DIN11851/316L Ra < 0.3 µm
Bolting DN 25 PN 40 DIN11851/316L Ra < 0.8 µm
A54
A55
A56
CSA(NI)CL I,II,III, Div. 2,Groups A, B, C, D, E, F, G
BR-Ex d IIC T6...T2
CSA(IS)CL I, II, III Div. 1, Groups A, B, C, D, E, F, G
T
U
V
Bolting DN 40 PN 40 DIN11851/316L Ra < 0.3 µm
Bolting DN 40 PN 40 DIN11851/316L Ra < 0.8 µm
Bolting DN 40 PN 40 DIN11864-1 A/316L
Ra < 0.8 µm ZB3052
A57
A58
A60
Bolting DN 50 PN 25 DIN11851/316L Ra < 0.3 µm
Bolting DN 50 PN 25 DIN11851/316L Ra < 0.8 µm
Bolting DN 50 PN 25 DIN11864-1 A/316L
Ra < 0.8 µm ZB3052
A61
A62
A63
Hygienic w.compr.nut F40 PN 25/316L
Hygienic w.compr.nut F40 PN 25/316L Ra < 0.3 µm
Hygienic w.compr.nut F40 PN 25/316L Ra < 0.8 µm
A64
A65
A66
Varivent N50-40/316L Ra < 0.3 µm
Varivent N50-40/316L Ra < 0.8 µm
Varivent N125/100/316L Ra < 0.8 µm
A67
A68
A70
DRD flange PN 40/316L ZB3007
SMS DN 38/316L Ra < 0.8 µm6)
SMS DN 51 PN 6/316L Ra < 0.8 µm6)
A71
A72
A73
Swagelok VCR screwing ZG2579 PN 64/316L
Neumo biocontrol size 25 PN 16/316L Ra < 0.8 µm
Neumo biocontrol size 50 PN 16/316L Ra < 0.8 µm
A74
A75
A76
Neumo biocontrol size 65 PN 16/316L Ra < 0.8 µm
Neumo biocontrol size 80 PN 16/316L Ra < 0.8 µm
SÜDMO DN 50 PN 10/316L Ra < 0.8 µm
A77
A78
A80
Small flange DN 25 PN 1.5 DIN 28403/316L pol.
Ra < 0.8 µm
Small flange DN 40 PN 1.5 DIN 28403/316L pol.
Ra < 0.8 µm
Ingold connection PN 16/316L Ra < 0.8 µm
A81
Terminal DN 33.7 PN 40 DIN 11864-3-A-/316L BN2
Ra < 0.8 µm
Hygienic fl. DN 50 PN 16 DIN 11864-2-A-/316L
Ra < 0.8 µm
Flange DN 25 PN 6 Form C, DIN 2501/316L
A84
F
H
K
Process connection
Thread G¾" A, PN 64/316L
Thread G¾" A, PN 64/316L Ra < 0.8 µm
Thread ¾" NPT, PN 64/316L
A00
A01
A02
Thread ¾" NPT, PN 64/316L Ra < 0.8 µm
Thread ¾" NPT, PN 64/Monel
Thread G¾" A, PN 64/Hastelloy
A03
A04
A05
Thread ¾" NPT, PN 64/Hastelloy
Thread G1" A, PN 64/316L
Thread G1" A, PN 64/316L ECTFE coated
MB19826)
A06
A07
A08
coated6)
Thread G1" A, PN 64/316L PFA
Thread G1" A, PN 64/Monel
Thread G1" A, PN 64/316L Ra < 0.8 µm
A10
A11
A13
Thread 1" NPT, PN 64/316L
Thread 1" NPT, PN 64/316L ECTFE coated MB19826)
Thread 1" NPT, PN 64/316L PFA coated6)
A14
A15
A16
Thread 1" NPT, PN 64/Monel
Thread 1" NPT, PN 64/316L Ra < 0.8 µm
Thread G1" A, PN 64/Hastelloy
A17
A18
A20
Thread G1½" A, PN 64/316L
Thread G1½" A, PN 64/316L Ra <0.8 µm
Thread G1½" A, PN 64/Hastelloy
A21
A22
A23
Thread 1" NPT, PN 64/Hastelloy
Thread 1½" NPT, PN 64/316L
Thread 1½" NPT, PN 64/316L Ra< 0.8 µm
A24
A25
A26
Thread 1½" NPT, PN 64/Hastelloy
Thread G2" A, PN 64/316L
Thread M27x1.5 PN 64/316L
A27
A28
A30
4/94
Siemens FI 01 · 2015
A82
A83
A85
A86
© Siemens AG 2014
Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL200
Selection and Ordering data
Article No.
Selection and Ordering data
Article No.
SITRANS LVL200, Rigid extension
Compact vibrating level switch for material detection in liquid applications such as overflow, high,
low, and demand applications, as well as pump
protection. For use in SIL-2 and hazardous applications.
7ML5747-
SITRANS LVL200, Rigid extension
Compact vibrating level switch for material detection in liquid applications such as overflow, high,
low, and demand applications, as well as pump
protection. For use in SIL-2 and hazardous applications.
7ML5747-
77 7 77 - 77 77
7 7 7 77 - 77 7 7
Flange DN 25 PN 6 Form C, DIN 2501/PFA6)
Flange DN 25 PN 40 Form C, DIN 2501/316L
Flange DN 25 PN 40 Form C, DIN 2501/Hastelloy
A87
A88
B00
Flange DN 80 PN 40 Form N, DIN 2501/316L
Flange DN 80 PN 40 Form N, DIN 2501/Hastelloy
Flange DN 100 PN 16 Form C, DIN 2501/316L
B57
B58
B60
Flange DN 25 PN 40 Form C, DIN 2501/ECTFE6)
Flange DN 25 PN 40 Form C, DIN 2501/PFA6)
Flange DN 25 PN 40 Form D, DIN 2501/316L
B01
B02
B03
Flange DN 100 PN 16 Form C, DIN 2501/Hastelloy
Flange DN 100 PN 16 Form C, DIN 2501/ECTFE6)
Flange DN 100 PN 16 Form C, DIN 2501/PFA6)
B61
B62
B63
Flange DN 25 PN 40 Form F, DIN 2501/316L
Flange DN 25 PN 40 Form N, DIN 2501/316L
Flange DN 25 PN 40 Form N, DIN 2501/Hastelloy
B04
B05
B06
Flange DN 100 PN 16 Form D, DIN 2501/316L
Flange DN 100 PN 16 Form F, DIN 2501/316L
Flange DN 100 PN 16 Form N, DIN 2501/316L
B64
B65
B66
Flange DN 25 PN 40 Form N, DIN 2501/Monel solid
Flange DN 25 PN 40 V13, DIN 2501/316L
B07
B08
Flange DN 32 PN 40 Form C, DIN 2501/316L
B10
Flange DN 100 PN 40 Form C, DIN 2501/316L
Flange DN 100 PN 40 Form C, DIN 2501/ECTFE6)
Flange DN 100 PN 40 Form C, DIN 2501/PFA6)
B67
B68
B70
Flange DN 32 PN 40 Form C, DIN 2501/ECTFE6)
Flange DN 40 PN 6 Form C, DIN 2501/316L
Flange DN 40 PN 6 Form C, DIN 2501/ECTFE6)
B11
B12
B13
Flange DN 100 PN 40 Form C, DIN 2501/
Enamelled7)
Flange DN 100 PN 40 Form F, DIN 2501/316L
Flange DN 100 PN 40 Form N, DIN 2501/316L
B71
Flange DN 40 PN 40 Form C, DIN 2501/316L
Flange DN 40 PN 40 Form C, DIN 2501/Hastelloy
Flange DN 40 PN 40 Form C, DIN 2501/ECTFE6)
B14
B15
B16
Flange DN 100 PN 40 V13, DIN 2501/316L
Flange DN 100 PN 64 Form E, DIN 2501/316L
Flange DN 100 PN 100 Form E, DIN 2501/316L
B74
B75
B76
Flange DN 40 PN 40 Form C, DIN 2501/PFA6)
Flange DN 40 PN 40 Form C, DIN 2501/Enamelled7)
Flange DN 40 PN 40 Form F, DIN 2501/316L
B17
B18
Flange DN 100 PN 100 Form L, DIN 2501/316L
Flange DN 125 PN 16 Form F, DIN 2501/316L
Flange DN 125 PN 40 Form C, DIN 2501/316L
B77
B78
B80
Flange DN 40 PN 40 Form N, DIN 2501/316L
Flange DN 40 PN 40 Form E, DIN 2501/316L
Flange DN 40 PN 40 V13, DIN 2501/316L
B21
B22
B23
Flange DN 125 PN 40 Form N, DIN 2512/316L
Flange DN 150 PN 16 Form C, DIN 2501/316L
Flange DN 150 PN 16 Form C, DIN 2501/Hastelloy
B81
B82
B83
Flange DN 50 PN 40 Form C, DIN 2501/316L
Flange DN 50 PN 40 Form C, DIN 2501/Hastelloy
Flange DN 50 PN 40 Form C, DIN 2501/ECTFE6)
B24
B25
B26
Flange DN 150 PN 16 Form C, DIN 2501/ECTFE6)
Flange DN 150 PN 16 Form C, DIN 2501/PFA6)
Flange DN 150 PN 16 Form D, DIN 2501/316L
B84
B85
B86
Flange DN 50 PN 40 Form C, DIN 2501/ECTFE
(ZB3108)6)
Flange DN 50 PN 40 Form C, DIN 2501/PFA6)
Flange DN 50 PN 40 Form D, DIN 2501/316L
B27
Flange DN 150 PN 40 Form C, DIN 2501/316L
Flange DN 150 PN 40 Form C, DIN 2501/Hastelloy
Flange DN 150 PN 40 Form F, DIN 2501/316L
B87
B88
C00
Flange DN 50 PN 40 Form D, DIN 2501/Hastelloy
Flange DN 50 PN 40 Form F, DIN 2501/316L
Flange DN 50 PN 40 Form N, DIN 2501/316L
B31
B32
B33
Flange DN 150 PN 40 Form N, DIN 2512/316L
Flange DN 200 PN 10 Form C, DIN 2501/ECTFE6)
Flange DN 200 PN 16 Form C, DIN 2501/316L
C01
C02
C03
Flange DN 50 PN 40 Form N, DIN 2501/Hastelloy
Flange DN 50 PN 40 Form E, DIN 2501/316L
Flange DN 50 PN 40 V13, DIN 2501/316L
B34
B35
B36
Flange DN 25 PN 40 Form B1, EN 1092-1/316L
Flange DN 25 PN 40 Form B1, EN 1092-1/Hastelloy
Flange DN 25 PN 40 Form B1, EN/316L/PFA6)
C04
C05
C06
B37
B38
B40
Flange DN 25 PN 40 Form B1, EN 1092-1/
Enamelled7)
Flange DN 25 PN 40 Form B2, EN 1092-1/316L
Flange DN 25 PN 40 Form F, EN 1092-1/316L
C07
Flange DN 50 PN 40 R13, DIN 2501/316L
Flange DN 50 PN 64 Form F, DIN 2501/316L
Flange DN 50 PN 64 Form N, DIN 2501/Hastelloy
Flange DN 50 PN 64 Form C, DIN 2501/316L
Flange DN 50 PN 64 Form L, DIN 2501/316L
Flange DN 50 PN 100 Form E, DIN 2501/316L
B41
B42
B43
Flange DN 25 PN 63 Form B1, EN 1092-1/316L
Flange DN 25 PN 100 Form B2, EN 1092-1/316L
Flange DN 40 PN 40 Form B1, EN/316L
C11
C12
C13
Flange DN 50 PN 100 Form L, DIN 2501/316L
Flange DN 65 PN 40 Form C, DIN 2501/316L
Flange DN 65 PN 40 Form C, DIN 2501/Hastelloy
B44
B45
B46
Flange DN 40 PN 40 Form B1, EN 1092-1/PFA6)
Flange DN 40 PN 40 Form B2, EN/316L
Flange DN 50 PN 40 Form B1, EN/316L
C14
C15
C16
Flange DN 65 PN 40 Form C, DIN 2501/ECTFE6)
Flange DN 65 PN 40 Form C, DIN 2501/PFA6)
Flange DN 65 PN 40 Form F, DIN 2501/316L
B47
B48
B50
Flange DN 50 PN 40 Form B1, EN 1092-1/Hastelloy
Flange DN 50 PN 40 Form B1,EN 1092-1/
Monel ZB2977
Flange DN 50 PN 40 Form B1, EN 1092-1/ECTFE6)
C17
C18
Flange DN 65 PN 64 Form E, DIN 2501/316L
Flange DN 80 PN 40 Form C, DIN 2501/316L
Flange DN 80 PN 40 Form C, DIN 2501/Hastelloy
B51
B52
B53
Flange DN 80 PN 40 Form C, DIN 2501/ECTFE6)
Flange DN 80 PN 40 Form C, DIN 2501/PFA6)
Flange DN 80 PN 40 Form F, DIN 2501/316L
B54
B55
B56
B20
B28
B30
EN/316L/PFA6)
Flange DN 50 PN 40 Form B1,
Flange DN 50 PN 40 Form B1, EN 1092-1/
Enamelled7)
Flange DN 50 PN 40 Form C, EN 1092-1/316L
4
B72
B73
C08
C10
C20
C21
C22
C23
Siemens FI 01 · 2015
4/95
© Siemens AG 2014
Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL200
4
Selection and Ordering data
Article No.
Selection and Ordering data
Article No.
SITRANS LVL200, Rigid extension
Compact vibrating level switch for material detection in liquid applications such as overflow, high,
low, and demand applications, as well as pump
protection. For use in SIL-2 and hazardous applications.
7ML5747-
SITRANS LVL200, Rigid extension
Compact vibrating level switch for material detection in liquid applications such as overflow, high,
low, and demand applications, as well as pump
protection. For use in SIL-2 and hazardous applications.
7ML5747-
77 7 77 - 77 77
7 7 7 77 - 77 7 7
Flange DN 50 PN 40 Form D, EN/316L
Flange DN 50 PN 40 Form D, EN 1092-1/
Hastelloy
Flange DN 50 PN 40 Form B2, EN 1092-1/316L
C24
C25
Flange 2" 300 lb RF, ANSI B16.5/ECTFE6)
Flange 2" 300 lb RF, ANSI B16.5/PFA6)
C82
C83
C26
Flange DN 50 PN 40 Form E, EN 1092-1/316L
Flange DN 80 PN 40 Form B1, EN 1092-1/316L
Flange DN 80 PN 40 Form B1, EN 1092-1/Hastelloy
C27
C28
C30
Flange 2" 300 lb RF, ANSI B16.5 Enamelled7)
Flange 2" 300 lb RJF, ANSI B16.5/316L
Flange 2" 300 lb ST, ANSI B16.5/316L
C84
C85
C86
Flange DN 80 PN 40 Form B1, EN
Flange DN 80 PN 40 Form B1, EN 1092-1/
Enamelled7)
Flange DN 80 PN 40 Form B2, EN 1092-1/316L
C31
C32
Flange 2" 300 lb LG (large groove),
ANSI B16.5/316L
Flange 2" 300 lb LT, ANSI B16.5/316L
Flange 2" 600 lb RF, ANSI B16.5/316L
C87
1092-1/ECTFE6)
Flange DN 100 PN 16 Form B1, EN 1092-1/316L
Flange DN 100 PN 16 Form B1, EN 1092-1/
Hastelloy
Flange DN 100 PN 16 Form B1, EN 1092-1/
Enamelled7)
C34
C35
Flange 2" 600 lb RF, ANSI B16.5/Monel ZB2977
Flange 2" 600 lb RF, ANSI B16.5/ECTFE6)
Flange 2" 600 lb RJF, ANSI B16.5/316L
D01
D02
D03
Flange 2" 600 lb LG, ANSI B16.5/316L
Flange 2" 900 lb RJF, ANSI B16.5/316L
Flange 2½" 150 lb RF, ANSI B16.5/316L
D04
D05
D06
Flange DN 100 PN 40 Form B1, EN 1092-1/316L
Flange DN 100 PN 40 Form B1, EN 1092-1/
Enamelled7)
Flange DN 100 PN 40 Form C, EN 1092-1/316L
C37
C38
Flange 2½" 300 lb RF, ANSI B16.5/316L
Flange 3" 150 lb RF, ANSI B16.5/316L
D07
D08
Flange 3" 150 lb RF, ANSI B16.5/Hastelloy
D10
Flange DN 100 PN 63 Form B2, EN 1092-1/316L
Flange DN 150 PN 16 Form B1, EN 1092-1/316L
Flange DN 150 PN 16 Form B1, EN 1092-1/PFA6)
C41
C42
C43
Flange 3" 150 lb RF, ANSI B16.5//Monel ZB2977
Flange 3" 150 lb RF, ANSI B16.5/ECTFE6)
Flange 3" 150 lb RF, ANSI B16.5/PFA6)
D11
D12
D13
Flange DN 150 PN 40 Form B1, EN 1092-1/316L
Flange DN 150 PN 40 Form B1, EN 1092-1/
ECTFE6)
Flange DN 150 PN 40 Form B2, EN 1092-1/316L
C44
C45
Flange 3" 150 lb RF, ANSI B16.5/Enamelled7)
Flange 3" 150 lb FF, ANSI B16.5/316L
Flange 3" 150 lb FF, ANSI B16.5/ECTFE6)
D14
D15
D16
Flange 1" 150 lb ANSI B16.5/316L
Flange 1"150 lb RF, ANSI B16.5/Hastelloy
Flange 1"150 lb RF, ANSI B16.5//Monel ZB2977
C47
C48
C50
Flange 3" 150 lb FF, ANSI B16.5/PFA6)
Flange 3" 300 lb RF, ANSI B16.5/316L
Flange 3" 300 lb RF, ANSI B16.5/Hastelloy
D17
D18
D20
Flange 3" 300 lb RF, ANSI B16.5/ECTFE6)
Flange 3" 300 lb RF, ANSI B16.5/PFA6)
Flange 3" 300 lb RF, ANSI B16.5/Enamelled7)
D21
D22
D23
Flange 3" 600 lb RF, ANSI B16.5/316L
Flange 3½" 150 lb RF, ANSI B16.5/316L
Flange 3½" 150 lb RF, ANSI B16.5/ECTFE6)
D24
D25
D26
Flange 4" 150 lb RF, ANSI B16.5/316L
Flange 4" 150 lb RF, ANSI B16.5/Hastelloy
Flange 4" 150 lb RF, ANSI B16.5/ECTFE6)
D27
D28
D30
Flange 4" 150 lb RF, ANSI B16.5/PFA6)
Flange 4" 150 lb RF, ANSI B16.5/Enamelled7)
Flange 4" 150 lb LT, ANSI B16.5/316L
D31
D32
D33
Flange 4" 300 lb RF, ANSI B16.5/316L
Flange 4" 300 lb RF, ANSI B16.5/Hastelloy
Flange 4" 300 lb RF, ANSI B16.5/ECTFE6)
D34
D35
D36
Flange 4" 300 lb RJF, ANSI B16.5/316L
Flange 4" 300 lb LG, ANSI B16.5/316L
Flange 4" 300 lb LT, ANSI B16.5/316L
D37
D38
D40
Flange 4" 600 lb RF, ANSI B16.5/316L
Flange 4" 600 lb RJF, ANSI B16.5/316L
Flange 5" 150 lb RF, ANSI B16.5/316L
D41
D42
D43
Flange 6" 150 lb RF, ANSI B16.5/316L
Flange 6" 150 lb RF, ANSI B16.5/Hastelloy
Flange 6" 150 lb RF, ANSI B16.5/ECTFE6)
D44
D45
D46
Flange 6" 150 lb RF, ANSI B16.5/PFA6)
Flange 6" 150 lb RJF, ANSI B16.5/316L
Flange 6" 300 lb RF, ANSI B16.5/316L
D47
D48
D50
Flange 8" 150 lb RF, ANSI B16.5/316L
Flange 8" 150 lb RF, ANSI B16.5/ECTFE6)
Flange 1" BS.10 Table E/316L
D51
D52
D53
B16.5/ECTFE6)
C33
C36
C40
C46
Flange 1" 150 lb RF, ANSI
Flange 1"150 lb RF, ANSI B16.5/PFA6)
Flange 1" 150 lb RF, ANSI B16.5/Enamelled7)
C51
C52
C53
Flange 1" 300 lb RF, ANSI B16.5/316L
Flange 1" 300 lb RF, ANSI B16.5/ECTFE6)
C54
C55
Flange 1" 600 lb RF, ANSI B16.5/316L
C56
Flange 1½" 150 lb RF, ANSI B16.5/316L
Flange 1½" 150 lb RF, ANSI B16.5/Hastelloy
Flange 1½" 150 lb RF, ANSI B16.5/ECTFE6)
C57
C58
C60
Flange 1½" 150 lb RF, ANSI B16.5/PFA6)
Flange 1½" 150 lb RF, ANSI B16.5 Enamelled7)
Flange 1½" 150 lb FF, ANSI B16.5/ECTFE6)
C61
C62
C63
Flange 1½" 300 lb RF, ANSI B16.5/316L
Flange 1½" 300 lb RF, ANSI B16.5//Monel ZB2977
Flange 1½" 300 lb RF, ANSI B16.5/ECTFE6)
C64
C65
C66
Flange 1½" 600 lb RF, ANSI B16.5/316L
Flange 2" 150 lb RF, ANSI B16.5/316L
Flange 2" 150 lb RF, ANSI B16.5/Hastelloy
C67
C68
C70
Flange 2" 150 lb RF, ANSI B16.5//Monel ZB2977
Flange 2" 150 lb RF, ANSI B16.5/ECTFE6)
Flange 2" 150 lb RF, ANSI B16.5/PFA6)
C71
C72
C73
Flange 2" 150 lb RF, ANSI B16.5/Enamelled7)
Flange 2" 150 lb FF, ANSI B16.5/316L
Flange 2" 150 lb FF, ANSI B16.5/ECTFE6)
C74
C75
C76
Flange 2" 150 lb SG (small groove),
ANSI B16.5/316L
Flange 2" 300 lb RF, ANSI B16.5/316L
Flange 2" 300 lb RF, ANSI B16.5/Hastelloy
C77
4/96
Siemens FI 01 · 2015
C78
C80
C88
D00
© Siemens AG 2014
Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL200
Selection and Ordering data
Article No.
Selection and Ordering data
Article No.
SITRANS LVL200, Rigid extension
Compact vibrating level switch for material detection in liquid applications such as overflow, high,
low, and demand applications, as well as pump
protection. For use in SIL-2 and hazardous applications.
7ML5747-
SITRANS LVL200, Rigid extension
Compact vibrating level switch for material detection in liquid applications such as overflow, high,
low, and demand applications, as well as pump
protection. For use in SIL-2 and hazardous applications.
7ML5747-
Flange 1" BS.10 Table E/PFA6)
Flange 1½" BS.10 Table E/316L
Flange 3½" BS.10 Table E/316L
E/ECTFE6)
77 7 77 - 77 77
Rigid Extension 316L Ra  0.8 μm
D54
D55
D56
Flange 4" BS.10 Table
Flange DN 40 10K, JIS/316L
Flange DN 50 10K, JIS/316L
D57
D58
D60
Flange DN 80 10K, JIS/316L
Flange DN 100 10K, JIS/316L
D61
D62
Adapter/Process temperature
Without adapter/-50 ... +150 °C
With adapter/-50 ... +200 °C8)
With adapter/-50... +250 °C
1
2
3
With gas-tight leadthrough/-50 ... +150 °C
With gas-tight leadthrough/-50 ... +250 °C
4
5
80 ... 500 mm
501 ... 1 000 mm
1 001 ... 1 500 mm
D0
D1
D2
1 501 ... 2 000 mm
2 001 ... 2 500 mm
2 501 ... 3 000 mm
D3
D4
D5
3 001 ... 3 500 mm
3 501 ... 4 000 mm
D6
D7
Rigid Extension 316L Ra  0.3 μm
Housing/ Cable entry
Aluminium IP66/IP67/M20x1.5
Aluminium IP66/IP67/½" NPT
316L stainless steel (electropolished)
IP66/IP67/M20X1.59)10)
316L stainless steel (electropolished)
IP66/IP67/½" NPT9)10)
7 7 7 77 - 77 7 7
A
B
C
80 ... 500 mm
501 ... 1 000 mm
1 001 ... 1 500 mm
E0
E1
E2
1 501 ... 2 000 mm
2 001 ... 2 500 mm
2 501 ... 3 000 mm
E3
E4
E5
3 001 ... 3 500 mm
3 501 ... 4 000 mm
E6
E7
Rigid Extension Enamelled version7)
D
NOTE:
When selecting a Rigid Extension option,
extension coating must match the process
connection coating and the material and
surface roughness type.
Rigid Extension 316L
80 ... 250 mm
251 ... 500 mm
501 ... 750 mm
F0
F1
F2
751 ... 1 000 mm
1 001 ... 1 250 mm
1 251 ... 1 500 mm
F3
F4
F5
Rigid Extension Hastelloy
80 ... 500 mm
501 ... 1 000 mm
1 001 ... 1 500 mm
A0
A1
A2
80 ... 500 mm
501 ... 1 000 mm
1 001 ... 1 500 mm
G0
G1
G2
1 501 ... 2 000 mm
2 001 ... 2 500 mm
2 501 ... 3 000 mm
A3
A4
A5
1 501 ... 2 000 mm
2 001 ... 2 500 mm
2 501 ... 3 000 mm
G3
G4
G5
3 001 ... 3 500 mm
3 501 ... 4 000 mm
A6
A7
3 001 ... 3 500 mm
3 501 ... 4 000 mm
G6
G7
Rigid Extension ECTFE coated6)
Rigid Extension Monel
80 ... 500 mm
501 ... 1 000 mm
1 001 ... 1 500 mm
B0
B1
B2
80 ... 500 mm
501 ... 1 000 mm
1 001 ... 1 500 mm
H0
H1
H2
1 501 ... 2 000 mm
2 001 ... 2 500 mm
2 501 ... 3 000 mm
B3
B4
B5
1 501 ... 2 000 mm
2 001 ... 2 500 mm
2 501 ... 3 000 mm
H3
H4
H5
Rigid Extension PFA coated6)
1)
Available with Adapter/Process temperature options 1, 3, 4, and 5 only
80 ... 500 mm
501 ... 1 000 mm
1 001 ... 1 500 mm
C0
C1
C2
2)
Available with Electronics option 4 only
3)
Available with Adapter/Process temperature options 1 and 3 only
4)
Extension length restricted to 2 956 mm
1 501 ... 2 000 mm
2 001 ... 2 500 mm
2 501 ... 3 000 mm
C3
C4
C5
5)
Available with Housing/Cable entry option B only
6)
Available with Adapter/Process temperature options 1 and 4 only
7)
Available with Adapter/Process temperature options 1, 2, and 4 only
8)
Available with enamelled Process connection and Extension options only
9)
Available with Approval options A, B, C only
10)
Not available with SIL/IEC61508 Certificate of conformity
(SIL-2 min. and max. detection)
Siemens FI 01 · 2015
4/97
4
© Siemens AG 2014
Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL200
Selection and Ordering data
4
Order code
Selection and Ordering data
Order code
Further designs
Spare Parts and Accessories
Please add "-Z" to Article No. and specify Order
code(s).
Electronics module SITRANS LVL200 Relay
Electronics module SITRANS LVL200 Contactless
Lock fitting, unpressurized, G1" A/316L
7ML1830-1NC
7ML1930-6AA
7ML1930-1DQ
Lock fitting, unpressurized, 1" NPT/316L
Lock fitting, unpressurized, G1 ...1/2" A/316L
Lock fitting, unpressurized, 1 ... 1/2" NPT/316L
7ML1930-1DR
7ML1930-1DS
7ML1930-1DT
Lock fitting, -1 ... 16 bar, G1" A/316L
Lock fitting, -1 ... 16 bar, 1" NPT/316L
Lock fitting, -1 ... 16 bar, G1 ... 1/2" A/316L
7ML1930-1DU
7ML1930-1DV
7ML1930-1DW
Lock fitting, -1 ... 16 bar, 1 ... 1/2" NPT/316L
Lock fitting, -1 ... 64 bar, G1" A/316L
Lock fitting, -1 ... 64 bar, 1" NPT/316L
7ML1930-1DX
7ML1930-1EA
7ML1930-1EB
Lock fitting, -1 ... 64 bar, G1 ... 1/2" A/316L
Lock fitting, -1 ... 64 bar, 1 ... 1/2" NPT/316L
7ML1930-1EC
7ML1930-1ED
Cleaning including Certificate
(oil, grease and silicone free)
W01
Enter the total insertion length in plain text
description, max. 4 000 mm (157.48 inch)
Y01
Identification Label (measurement loop) stainless
steel: max. 16 characters add in plain text
Y17
Identification Label (measurement loop) Foil:
max. 16 characters add in plain text
Y18
Acceptance test certificate 3.1 NACE MR 0775 for
material EN102041)
D07
Acceptance test certificate 3.1 for instrument
EN102041)
C12
Acceptance test Certificate 2.2 for material
EN102041)
C15
Functional Safety (SIL 2). Device suitable for use in
accordance with IEC 61508 and IEC 615111)
C20
Dye penetration test + 3.1 certificate/instrument1)
C13
X-ray test + 3.1
certificate/instrument1)
C14
Positive material identification test
+ 3.1 certificate/instrument1)
C16
Roughness test + 3.1 certificate/instrument1)
C18
Pressure test + 3.1 certificate/instrument1)
C31
Helium leak test + 3.1 certificate/instrument1)
C32
Ferrite measuring accuracy to DIN32514-1
+ 3.1 certificate/instrument1)
C60
Pressure test according to Norsok
+ 3.1 certificate/instrument1)
C61
Additional Operating Instructions
Article No.
LVL200 Extended (DPDT Relay)
• English
7ML1998-5KW01
• French
7ML1998-5KW11
• Spanish
7ML1998-5KW21
• German
7ML1998-5KW31
LVL200 (Contactless electronic switch)
• English
7ML1998-5KV01
• French
7ML1998-5KV11
• Spanish
7ML1998-5KV21
• German
7ML1998-5KV31
Electronics module LVL200 Relay
• English
7ML1998-5LS01
• French
7ML1998-5LS11
• Spanish
7ML1998-5LS21
• German
This device is shipped with the Siemens Milltronics
manual DVD containing the Operating Instructions
library.
7ML1998-5LS31
4/98
Siemens FI 01 · 2015
1)
Listed Certificates are not available with all configurations, please contact
factory for more information
© Siemens AG 2014
Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL200
■ Options
LVL200 threaded welded socket
Lock fitting
G1" A/316L
G¾" A/316L
32 (1.26)
G¾"
LVL200 extended
64 bar
LVL200 extended
16 bar
LVL200 extended
unpressurized
32
(1.26)
29,5
(1.16)
39 (1.54)
G1"
53 (2.09)
60 (2.36)
4
SITRANS LVL200 welded socket and lock fitting, dimensions in mm (inch)
Siemens FI 01 · 2015
4/99
© Siemens AG 2014
Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL200
■ Characteristic curves
Ambient temperature in °C (°F)
Ambient/Process temperature
Temperature range with
temperature adapter
70 ºC
(158 ºF)
40 ºC
(104 ºF)
-50 ºC
(-58 ºF)
4
0 ºC
(32 ºF) 0 ºC
(32 ºF)
50 ºC
(122 ºF)
100 ºC
(212 ºF)
150 ºC
(302 ºF)
-40 ºC
(-40 ºF)
200 ºC
(392 ºF)
250 ºC
(482 ºF)
Process temperature in °C (°F)
Process pressure in bar (psi g)
Process pressure with switch position 0.7 g/cm³ (mode switch)
-50 ºC
(-58 ºF)
64
(928)
40
(580)
20
(290)
-1
(-14.5)
0 ºC
(32 ºF)
50 ºC
(122 ºF)
100 ºC
(212 ºF)
150 ºC
(302 ºF)
200 ºC
(392 ºF)
250 ºC
(482 ºF)
Process temperature in °C (°F)
Process pressure in bar (psi g)
Process pressure with switch position 0.5 g/cm³ (mode switch)
-50 ºC
(-58 ºF)
64
(928)
40
(580)
20
(290)
-1
(-14.5)
0 ºC
(32 ºF)
50 ºC
(122 ºF)
100 ºC
(212 ºF)
150 ºC
(302 ºF)
200 ºC
(392 ºF)
250 ºC
(482 ºF)
Process temperature in °C (°F)
SITRANS LVL200 Process Pressure/Process Temperature/Ambient Temperature derating curves
4/100
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL200
■ Dimensional drawings
SITRANS LVL200 (Standard)
Stainless Steel enclosure
~ 59
(2.32 )
Ø 80
(3.15)
Aluminium enclosure
~116 (4.57)
Ø84 (3.31)
M20 x 1.5 or
½" NPT
M20 x 1,5 or
½" NPT
Tri-clamp
57
(2.24)
Flange
Gas-tight leadthrough
34
(1.34)
Ø33.7 (1.33)
53
(2.09)
53
(2.09)
50
(1.97)
19
(0.75)
Bolting DN 40
Temperature adapter
178 (7.01)
G ¾" A, ¾" NPT
G 1" A, 1" NPT
Cone DN 25
55
(2.17)
SW 32
(G ¾" A, ¾" NPT)
SW 41
(G 1" A, 1" NPT)
36
53 (2.09) (1.42)
66
(2.60)
18.5
(0.73)
Threaded
125 (4.92)
112
(4.41)
M20 x 1.5
SITRANS LVL200 (Standard), dimensions in mm (inch)
Siemens FI 01 · 2015
4/101
4
© Siemens AG 2014
Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL200
SITRANS LVL200 (Extended)
Sensor length (L)
Stainless Steel Enclosure
~ 59
(2.32)
Aluminium Enclosure
~ 116
(4.57)
Ø 80
(3.15)
Ø 84
(3.31)
316L, Hastelloy C4 (2.4610)
80 ... 6 000 mm (3.15 ... 236.2 inch)
Hastelloy C4 (2.4610) enamelled
80 ... 1 500 mm (3.15 ... 59.06 inch)
316L, ECTFE coated
80 ... 3 000 mm (3.15 ... 118.1 inch)
316L, PFA coated
80 ... 3 000 mm (3.15 ... 118.1 inch)
112
(4.41)
M20 x1.5
125
(4.92)
M20x1.5 or
½" NPT
M20x 1,5 or
½" NPT
Threaded
Tri-clamp
Cone DN 25
4
32 (G ¾" A, ¾" NPT)
41 (G 1" A, 1" NPT)
18.5
(0.73)
57
(2.24)
36
(1.42)
G ¾" A, ¾" NPT
G 1" A, 1" NPT
L
L
Bolting DN 40
Temperature adapter
L
Flanged
Gas-tight leadthrough
178
(7.01)
19
(0.75)
50
(1.97)
34
(1.34)
L
L
SITRANS LVL200 (Extended), dimensions in mm (inch)
4/102
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL200
■ Schematics
Relay (DPDT)
+ –
L1 N
1
2
20 - 72 V DC
20 - 253 V AC
3
1
1
Control lamp
2
DIL switch for characteristics reversal
3
DIL switch for sensitivity adjustment
4
Ground terminal
5
Connection terminals
2
3
4
5
6
7
8
6
4
Relay
output
Relay
output
Voltage
supply
Contactless
20-253V AC/DC
I max 400 mA
1 2
L N
1
1
A
B
1
1 2
L
N
≥0.5g/cm
≥0.7g/cm
2
3
2
5
1
Control lamp
2
DIL switch for mode adjustment
3
DIL switch for switching point adaptation
4
Ground terminal
5
Connection terminals
2
4
L1 N
AC + –
DC – +
Voltage
supply
NAMUR
N
NAMUR
(IEC 60947-5-6)
+ Simul.
6
+
–
1
2
max.
2
min.
5
1
3
1 2
4
1
Control lamp
2
DIL switch for characteristics reversal
3
DIL switch for sensitivity adjustment
4
Ground terminal
5
Simulation key
6
Connection terminals
+
–
Amplifier according to NAMUR
IEC 60947-5-6, approx. 8.2 V
SITRANS LVL200 connections
Siemens FI 01 · 2015
4/103
4
© Siemens AG 2014
Level Measurement
Point level measurement – Vibrating switches
SITRANS LVS100
■ Overview
■ Configuration
Installation
Rigid extension with
sliding sleeve
Position tines vertically to
avoid product build-up:
use a 50 mm open-end
wrench to turn the process
connection until the tine
orientation marking faces up
or down.
L
*
Protection in case of high
material loading.
O
4
Cable gland faces
downward to avoid
water penetration.
SITRANS LVS100 is a vibrating point level switch for material
detection in bulk solids.
■ Benefits
Tine orientation marking
facing sideways.
• High resistance to mechanical forces
• Sliding sleeve options for adjustable insertion length and ease
of cleaning
• Rotatable enclosure for ease of installation and wiring
• Suitable for point level detection of materials starting at a bulk
density of 30 g/l (1.9 lb/ft3)
• Customer desired extensions up to 4 000 mm (157.48 inch)
Use angle mounting for
flowing material only. If angle
mounting is required with high
material loading, customersupplied protection from
falling material must be in
place.
■ Application
SITRANS LVS100 detects high, low or demand levels of dry bulk
solids in bins, silos or hoppers.
SITRANS LVS100 has a compact design and can be top, side,
or angle mounted. The vibrating fork design ensures the tines
are kept clean. The unique design of the fork and crystal assembly eliminates false high level readings even if tines become
damaged.
A signal from the electronic circuit excites a crystal in the probe
causing the fork to vibrate. If the fork is covered by material,
the change in vibration is detected by the electronic circuitry
which causes the relay to change state after a one second delay.
When the fork is free from material pressure, full vibration
resumes and the relay reverts to its normal condition.
• Key Applications: dry bulk solids in bins, silos, hoppers
4/104
Siemens FI 01 · 2015
*
max. deviation
from vertical O
max. length L
5°
4.0 m
45°
1.2 m
> 45°
0.6 m
SITRANS LVS100 installation, dimensions in mm (inch)
© Siemens AG 2014
Level Measurement
Point level measurement – Vibrating switches
SITRANS LVS100
■ Technical specifications
Mode of Operation
Measuring principle
Vibrating point level switch
Input
Measured variable
High, low and demand
Measuring frequency
200 Hz
Design
Material
• Enclosure
Process connection
Epoxy coated aluminum
• Thread 1¼" NPT [(Taper),
ANSI/ASME B1.20.1],
R 1½" [(BSPT), EN 10226]
• Thread R 1½" [(BSPT),
EN 10226], ½" NPT [(Taper),
ANSI/ASME B1.20.1], sliding sleeve
[min. length 500 mm (19.69 inch)]
• Thread material:
stainless steel 304 (1.4301) or
316TI (1.4571) depending on
configuration
Tine material
Stainless steel 316TI (1.4571)
Degree of protection
IP66/Type 4/NEMA 4
Conduit entry
2 x M20x1.5 or 2 x ½" NPT
Weight
Standard version, no extensions:
approx. 1.7 kg (3.7 lb)
Power supply
• 19 ... 230 V AC, +10 %,
50 ... 60 Hz, 8 VA
• 19 ... 40 V DC, +10 %, 1.5 W
Certificates and approvals
•
•
•
•
•
•
Output
Relays
DPDT relay
Relay delay
From loss of vibration:
approximately 1 second
From resumption of vibration:
approximately 1 ... 2 s
Signal delay
Probe uncovered to covered:
approximately 1 s
Probe covered to uncovered:
approximately 1 ... 2 s
Relay fail-safe
High or low, switch selectable
Alarm output
Relay 8 A at 250 V AC, non-inductive
Relay 5 A at 30 V DC, non-inductive
Sensitivity
High or low, switch selectable
Rated operating conditions
Installation conditions
• Location
Indoor/outdoor
CSA/FM General Purpose
CE
CSA/FM Dust Ignition Proof
RCM
ATEX II 1/2 D
IECex
Ambient conditions
• Ambient temperature
-40 ... +60 °C (-40 ... +140 °F)
• Installation category
III
• Pollution degree
2
Medium conditions
• Process temperature
-40 ... +150 °C (-40 ... +302 °F)
• Max. threaded bushing temperature 60 °C (140 °F)
• Max. enclosure surface temperature 90 °C (194 °F)
(Category 2D)
• Max. extension surface temperature 150 °C (302 °F)
(Category 1D)
• Pressure (vessel)
Max. 10 bar g (145 psi g)
European Pressure Directive
97/23/EC: Category 1
Minimum material density
Approx. 30 g/l (1.9 lb/ft3)
Siemens FI 01 · 2015
4/105
4
© Siemens AG 2014
Level Measurement
Point level measurement – Vibrating switches
SITRANS LVS100
Selection and Ordering data
Article No.
SITRANS LVS100, standard
Vibrating point level switch for high or low level
detection of bulk solids. Sensitivity > 30 g/l.
7ML5735-
■ Dimensional drawings
77 7 77 - 07A 0
1½" NPT [(Taper), ANSI/ASME B1.20.1] ,
¢
sliding sleeve [min. length 500 mm (19.69 inch)]2)
Extension length
Stainless steel 316TI (1.4571)
Standard length, 170 mm (6.69 inch)
Add Order code Y01 and plain text:
"Insertion length ... mm"
Stainless steel 304 (1.4301)
• 300 ... 500 mm (11.81 ... 19.69 inch)
• 501 ... 1 000 mm (19.72 ... 39.37 inch)
• 1 001 ... 1 500 mm (39.41 ... 59.06 inch)
• 1 501 ... 2 000 mm (59.09 ... 78.74 inch)
A
60
(2.36)
A
B
C
120 (4.72)
Tine orientation
marking
D
Threaded bushing
[max. temp.
80 °C (176 °F)]
¢
11
¢
¢
¢
12
13
Zone 21
(cat. 2)
Zone 20
(cat. 1)
Customer supplied
process flange
14
15
¢
• 2 001 ... 2 500 mm (78.78 ... 98.43 inch)
• 2 501 ... 3 000 mm (98.46 ... 118.11 inch)
16
17
• 3 001 ... 3 500 mm (118.15 ... 137.80 inch)
• 3 501 ... 4 000 mm (137.83 ... 157.48 inch)
18
20
Approvals
CSA/FM General Purpose, CE, RCM
CSA/FM Class II, Div. 1, Group E, F, G, Class III,
ATEX II 1/2 D, RCM
IEC-Ex t IIIC Da/Db
150 (5.91)
4
¢
Process connection
Threaded
R 1½" [(BSPT), EN 10226]
¢
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
¢
R 1½" [(BSPT), EN 10226] DIN 2999 thread,
¢
sliding sleeve - min. length 500 mm (19.69 inch)2)
¢
¢
Tine
170 ... 4 000 (6.69 ... 157.48):
Customer specified rigid
Process temperature
Up to 150 °C (302 °F)
¢ 1
¢ 2
125 (4.92):
Standard fork
Input Voltage
DPDT Relay - 19 ... 230 V AC, 19 ... 40 V DC
DPDT Relay - 19 ... 230 V AC, 19 ... 40 V DC
(stocked version)1)
60
(2.36)
75 (2.95)
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
A
B
SITRANS LVS100, dimensions in mm (inch)
C
1)
Only available with the following configurations 7ML5735-2AA11-0AA0 or
7ML5735-2AB11-0AA0
2)
Not available with extension length options 11, 12
■ Schematics
Universal voltage (DPDT relay)
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Selection and Ordering data
Order code
Further Designs
Alarm
output
relay
FSH/FSL
adjustment
Sensitivity adjustment:
B = factory setting,
A = decreased
Please add "-Z" to Article No. and specify Order
code(s).
Total insertion length: Enter the total insertion length
in plain text description, max. (50 mm increments)
Y01
Signal bulb inserted in M20 cable gland1)
A20
Operating Instructions
Article No.
Multi-language
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
7ML1998-5FT63
Spare Parts
Replacement Electronics Module LVS100 DPDT
Relay (19 ... 253 V AC, 19 ... 55 V DC)
7ML1830-1NS
R 1½" [(BSPT), EN 10226] DIN 2999 thread,
sliding sleeve
7ML1830-1NT
1½" NPT [(Taper), ANSI/ASME B1.20.1] ,
sliding sleeve [min. length 500 mm (19.69 inch)]
7ML1830-1NU
1)
Available only with approval CE
4/106
Siemens FI 01 · 2015
876 543
LED
21
AC: Terminal 1: L
Terminal 2: N
19 ... 230 V AC, +10 %, 50 ... 60 Hz, 8 VA
DC: Terminal 1: +
Terminal 2: 19 ... 50 V DC, +10 %, 2 W
SITRANS LVS100 connections
© Siemens AG 2014
Level Measurement
Point level measurement – Vibrating switches
SITRANS LVS200
■ Overview
■ Application
The standard LVS200 detects high, low, or demand levels of dry
bulk solids in bins, silos, or hoppers. The liquid/solid interface
version can also detect settled solids within liquids or solids
within confined spaces such as feed pipes. It is designed to
ignore liquids in order to detect the interface between a solid
and a liquid.
A pipe extension version is available with either the standard or
liquid/solid interface electronics and fork, separated by a customer supplied 1 inch pipe.
SITRANS LVS200 has an optional 4 ... 20 mA output for monitoring buildup on the fork to determine when preventative maintenance should be performed in sticky applications.
The LVS200 has a compact design and can be top, side or angle
mounted. The vibrating fork design ensures the tines are kept
clean. The unique design of the fork and crystal assembly eliminates false high level readings even if tines become damaged.
SITRANS LVS200 is a vibrating point level switch for high, low,
or demand level detection of bulk solids.
■ Benefits
•
•
•
•
High resistance to mechanical forces
Strong vibration resistance to high bulk material loads
Rotatable enclosure for convenient wiring
Suitable for low density material: standard version, 20 g/l
(1.3 lb/ft3); liquid/solid interface version, 50 g/l (3 lb/ft3)
and low density option min. 5 g/l (0.3 lb/ft3)
• Customer desired extensions up to 20 000 mm (787 inch)
• Optional detection of solids within liquid
• Durable short fork option with 165 mm (6.5 inch) insertion
length
A signal from the electronic circuit excites a crystal in the probe
causing the fork to vibrate. If the fork is covered by material, the
change in vibration is detected by the electronic circuitry which
causes the relay to change state after a one second delay.
When the fork is free from material pressure, full vibration
resumes and the relay reverts to its normal condition.
• Key Applications: dry bulk solids in bins, silos, hoppers or
settled solids within liquids (interface version)
Siemens FI 01 · 2015
4/107
4
© Siemens AG 2014
Level Measurement
Point level measurement – Vibrating switches
SITRANS LVS200
■ Technical specifications
Mode of operation
Measuring principle
Vibrating point level switch
Medium conditions
• Process temperature
Input
Measured variable
High, low and demand
Measuring frequency
• Standard
• Liquid/solid interface and short
fork version
125 Hz
350 Hz
Output
PNP
4
2-wire without contact
•
•
•
Open collector:
Permanent load max. 0.4 A,
short-circuit and overload protected
Turn-on voltage: max. 50 V (reverse
protection)
Load current:
• Min. 10 mA
• Max. 500 mA permanent
• Max. 2A < 200 ms
• Max. 5A < 50 ms
Voltage drop on the electronic
module: max. 7 V with closed
electric circuit
•
•
• All except CSA Class II, Group G:
-40 ... +150 °C (-40 ... +302 °F)
• CSA Class II, Group G:
-40 ... +140 °C (-40 ... +284 °F),
CSA temperature code T3B
Max. threaded bushing temperature 60 °C (140 °F)
Max. enclosure surface temperature 90 °C (194 °F)
(Category 2D)
Max. extension surface temperature 150 °C (302 °F)
(Category 1D)
Max. 10 bar g (145 psi g) European
Pressure (vessel)
Pressure Directive 97/23/EC:
Category 1
• Standard version: approx. 20 g/l
Minimum material density
(1.2 lb/ft3)
• Liquid/solid interface version:
approx. 50 g/l (3 lb/ft3)
• Optional low density version:
approx. 5 g/l (0.3 lb/ft3)
Design
Material
• Enclosure
Process connection
Cutoff current with open electric
circuit: max. 5 mA
Relays
• Version with 1 relay
• Version with 2 relays
Relay delay
mA output
• Resolution
SPDT relay
DPDT relay
• From loss of vibration:
approximately 1 second
• From resumption of vibration:
approximately 1 ... 2 seconds
• Probe uncovered to covered:
approximately 1 second
• Probe covered to
uncovered: approximately
1 ... 2 seconds
High or low, switch selectable
• Relay 8 A at 250 V AC,
non-inductive
• Relay 5 A at 30 V DC,
non-inductive
8/16 mA or 4 ... 20 mA
4 ... 20 mA ± 0.1 mA
Sensitivity
High or low, switch selectable
Signal delay
Relay fail-safe
Alarm output
Rated operating conditions
Installation conditions
• Location
Indoor/outdoor
Ambient conditions
• Ambient temperature
• Installation category
• Pollution degree
-40 ... +60 °C (-40 ... +140 °F)
III
2
4/108
Siemens FI 01 · 2015
Tine material
Degree of protection
Conduit entry
Weight
Epoxy coated aluminum
• Thread 1½" NPT [(Taper),
ANSI/ASME B1.20.1], R ½" [(BSPT),
EN 10226] and flange options
• Optional sliding bushing with
2" NPT [(Taper), ANSI/ASME
B1.20.1] or BSP thread
• Thread material: stainless steel 303
(1.4301)
Stainless steel 316TI (1.4571),
PTFE-coated tines are available
upon special request
IP65/Type 4/NEMA 4
2 x M20x1.5 or 2 x ½" NPT
• Standard version, no extensions:
approx 2.0 kg (4.4 lb)
• Solids/liquids version, no extensions:
approx. 1.9 kg (4.2 lb)
Power supply
• 19 ... 230 V AC, +10 %,
50 ... 60 Hz, 8 VA
• 19 ... 55 V DC, +10 %, 1.5 W
Certificates and approvals
•
•
•
•
•
•
CSA/FM General Purpose
CE
CSA/FM Dust Ignition Proof
RCM
ATEX II 1/2 D
CSA/FM IS Class I, II, III Div. 1,
Groups A, B, C, D, E, F, G,
FM Class 1, Aex ia IIC, CSA Class 1,
Ex ia IIC, available only with
power supply option 5 and 6
• ATEX II 1G and 1/2 G Eex ia IIC;
ATEX II 1D and 1/2 D, available
only with power supply option 5
© Siemens AG 2014
Level Measurement
Point level measurement – Vibrating switches
SITRANS LVS200
Selection and Ordering data
Article No.
Selection and Ordering data
Article No.
SITRANS LVS200, standard
SITRANS LVS200 is a vibrating point level switch
for high, low, or demand level detection of bulk
solids.
7ML5731-
SITRANS LVS200, standard
SITRANS LVS200 is a vibrating point level switch
for high, low, or demand level detection of bulk
solids.
7ML5731-
7 7 7 7 7 - 77 A 0
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Stainless steel 316L (1.4404)
Standard length, 235 mm (9.25 inch)
Power supply
19 ... 230 V AC, 19 ... 55 V DC, one relay output ¢
(SPDT)1)
19 ... 230 V AC, 19 ... 55 V DC, two relay outputs
(DPDT)1)
18 ... 50 V DC PNP1)
¢
Add Order code Y01 and plain text:
"Insertion length ... mm"
1
2
3
4
19 ... 230 V AC/DC without contact, 2-wire loop
powered1)
7 ... 9 V DC (requires NAMUR switch amplifier)
NAMUR IEC 60947-5-6, 2-wire2)
8/16 mA or 4 ... 20 mA; 12.5 ... 35 V DC, 2-wire3)
5
6
19 ... 230 V AC, 19 ... 55 V DC, one relay output }¢ 7
(SPDT) basic version4)5)
Process temperature
Without temperature isolator
}¢
With temperature isolator
Separated enclosure - cable length 1.5 m (4.92 ft)
[max. temperature process 150 °C (302 °F)/
max. temperature electronics 60 °C (140 °F)]
Separated enclosure - cable length 4.0 m (13.12 ft)
[max. temperature process150 °C (302 °F)/
max. temperature electronics 60 °C (140 °F)]
A
B
C
Process connection
Threaded
R 1½" [(BSPT), EN 10226]
1½" NPT [(Taper), ANSI/ASME B1.20.1]
G 2" [(BSPP), EN ISO 228-1], sliding sleeve
[min. length 500 mm (19.69 inch)]6)
}¢
}¢
300 ... 500 mm (11.81 ... 19.69 inch)
501 ... 750 mm (19.72 ... 29.53 inch)
751 ... 1 000 mm (29.57 ... 39.37 inch)
1 001 ... 1 250 mm (39.41 ... 49.21 inch)
32
33
34
35
1 251 ... 1 500 mm (49.25 ... 59.06 inch)
1 501 ... 1 750 mm (59.09 ... 68.90 inch)
1 751 ... 2 000 mm (68.94 ... 78.74 inch)
36
37
38
2 001 ... 2 250 mm (78.78 ... 88.58 inch)
2 251 ... 2 500 mm (88.62 ... 98.43 inch)
2 501 ... 2 750 mm (98.46 ... 108.27 inch)
2 751 ... 3 000 mm (108.31 ... 118.11 inch)
41
42
43
44
3 001 ... 3 250 mm (118.15 ... 127.95 inch)
3 251 ... 3 500 mm (127.99 ... 137.80 inch)
3 501 ... 3 750 mm (137.83 ... 147.64 inch)
3 751 ... 4 000 mm (147.68 ... 157.48 inch)
45
46
47
48
}¢
Approvals
CSA/FM Dust Ignition Proof, RCM
}¢
ATEX II 1/2 D, RCM
}¢
CSA/FM General Purpose, RCM
¢
CE, RCM
¢
CSA/FM IS Class I, II, III Div. 1, Groups A, B, C, D,
E, F, G, FM Class 1, Aex ia IIC, CSA Class 1,
Ex ia IIC, RCM
ATEX II 1G and 1/2G Eex ia IIC; ATEX II 1D and
1/2D, RCM
IEC-Ex t IIIC Da/Db
A
B
C
D
2" NPT [(Taper), ANSI/ASME B1.20.1],
sliding sleeve [min. length 500 mm (19.69 inch)]6)
Flanged
DN 100 PN 6, EN 1092-17)
DN 100 PN 16, EN 1092-1
31
Material process connection/extension
Stainless steel threads 304 (1.4301),
flanges 321 (1.4541), Tri-clamp 304 (1.4301)8)
Stainless steel 316L (1.4404)9)
D
7 7 7 7 7 - 77 A 0
E
F
2" ASME 150 lb B16.5
3" ASME 150 lb B16.5
4" ASME 150 lb B16.5
G
H
J
1)
3)
Available with Approval options B, D, G only
2" Tri-clamp (DN 50) ISO 2852
K
4)
Available with configurations 7ML5731-7AA11-1BA0 or
7ML5731-7AB11-1AA0 only
5)
Basic version is cost effective and offers fast delivery
6)
Not available with extension length options 11, 12, 31, 32
7)
Max. 6 bar (87 psi)
8)
Available with option extension length 11 ... 28
9)
Available with option extension length 31 … 48
Extension length
Stainless steel 304 (1.4301)
Standard length, 235 mm (9.25 inch)
}¢
11
Add Order code Y01 and plain text:
"Insertion length ... mm"
• 300 ... 500 mm (11.81 ... 19.69 inch)
• 501 ... 750 mm (19.72 ... 29.53 inch)
• 751 ... 1 000 mm (29.57 ... 39.37 inch)
¢
¢
¢
12
13
14
• 1 001 ... 1 250 mm (39.41 ... 49.21 inch)
• 1 251 ... 1 500 mm (49.25 ... 59.06 inch)
• 1 501 ... 1 750 mm (59.09 ... 68.90 inch)
¢
¢
¢
15
16
17
• 1 751 ... 2 000 mm (68.94 ... 78.74 inch)
• 2 001 ... 2 250 mm (78.78 ... 88.58 inch)
• 2 251 ... 2 500 mm (88.62 ... 98.43 inch)
¢
¢
¢
18
21
22
• 2 501 ... 2 750 mm (98.46 ... 108.27 inch)
• 2 751 ... 3 000 mm (108.31 ... 118.11 inch)
• 3 001 ... 3 250 mm (118.15 ... 127.95 inch)
¢
¢
¢
23
24
25
• 3 251 ... 3 500 mm (127.99 ... 137.80 inch)
• 3 501 ... 3 750 mm (137.83 ... 147.64 inch)
• 3 751 ... 4 000 mm (147.68 ... 157.48 inch)
¢
¢
¢
26
27
28
Available with Approval options A ... D, G only
2)
Available with Approval options D, E, F only
4
1
2
A
B
C
D
E
F
G
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
} Available ex stock. For details see page 9/5 in the appendix.
Siemens FI 01 · 2015
4/109
© Siemens AG 2014
Level Measurement
Point level measurement – Vibrating switches
SITRANS LVS200
Order code
Selection and Ordering data
Article No.
7ML5732-
Total insertion length: Enter the total insertion length
in plain text description, max. 4 000 mm
(157.48 inch)
Y01
SITRANS LVS200, short fork for liquids/
solids interface
Vibrating point level switch for solids or solids
within liquid interface applications, and high load
applications with short insertion requirements
Stainless steel tag [100 x 45 mm (3.94 x 1.77 inch)]:
Measuring-point number/identification
(max. 27 characters); specify in plain text
Y14
Enhanced sensitivity > 5 g/l via electronics and
increased fork length to 195 mm (7.68 inch)3)
K05
Enhanced sensitivity < 5 g/l via electronics,
increased fork length to 195 mm (7.68 inch),
and increased aluminum fork width 1)3)
G01
Signal bulb inserted in M20 cable gland2)
A20
Selection and Ordering data
Further Designs
Please add "-Z" to Article No. and specify Order
code(s).
4
NAMUR 8/16 mA switch amplifiers available,
contact factory for pricing
Operating Instructions
Multi-language
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
Article No.
7ML1998-5FT63
Spare Parts
Replacement Electronics Module (125 Hz)
[19 ... 230 V AC, 19 ... 55 V DC, one relay output
(SPDT)]
7ML1830-1KL
Sliding sleeve, 2" BSP (ISO 228)
7ML1830-1JM
Sliding sleeve, 2" NPT (ASME B1.20.1)
7ML1830-1JN
Namur Isolator switch amplifier relay output
KFD2-SR2-Ex1.W
A5E03496569
Available ex stock
For details see page 9/5 in the appendix.
SITRANS LVS200, standard, power supply 7,
process temperature A, process connection A,
extension length 11, material process connection/
extension 1, and approval B
7ML57317AA11-1BA0
SITRANS LVS200, standard, power supply 7,
process temperature A, process connection B,
extension length 11, material process connection/
extension 1, and approval A
7ML57317AB11-1AA0
1)
Available only with power supply 1 and Approval C, D and with
Process connection flange E ... J
2)
Available with Approval option D only
3)
K05 and G01 are not available together
4/110
Siemens FI 01 · 2015
77 7 77 - 77 A 0
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Power supply
19 ... 230 V AC, 19 ... 55 V DC, one relay output
(SPDT)
19 ... 230 V AC, 19 ... 55 V DC, two relay outputs
(DPDT)
18 ... 50 V DC PNP
19 ... 230 V AC/DC without contact, 2-wire loop
powered
8/16 mA or 4 ... 20 mA; 12.5 ... 35 V DC, 2-wire1)
¢ 1
2
3
4
5
Process temperature
Without temperature isolator
¢
With temperature isolator
Separated enclosure - cable length 1.5 m (4.92 ft)
[max. temperature process 150 °C (302 °F)/
max. temperature electronics 60 °C (140 °F)]
Separated enclosure - cable length 4.0 m (13.12 ft)
[max. temperature process 150 °C (302 °F)/
max. temperature electronics 60 °C (140 °F)]
Process connection
Threaded
R 1½" [(BSPT), EN 10226]
¢
1½" NPT [(Taper), ANSI/ASME B1.20.1]
¢
G 2" [(BSPP), EN ISO 228-1], sliding sleeve
[min. length 500 mm (19.69 inch)]2)
2" NPT [(Taper), ANSI/ASME B1.20.1],
sliding sleeve [min. length 500 mm (19.69 inch)]2)
Flanged
DN 100 PN 6, EN 1092-13)
DN 100 PN 16, EN 1092-1
A
B
C
D
A
B
C
D
E
F
G
H
J
K
2" ASME 150 lb B16.5
3" ASME 150 lb B16.5
4" ASME 150 lb B16.5
2" Tri-clamp (DN 50) ISO 2852
Extension length
Stainless steel 304 (1.4301)
Standard length, 165 mm (6.50 inch)
¢
11
Add Order code Y01 and plain text:
"Insertion length ... mm"
200 ... 500 mm (7.87 ... 19.69 inch)
501 ... 750 mm (19.72 ... 29.53 inch)
751 ... 1 000 mm (29.57 ... 39.37 inch)
¢
¢
¢
12
13
14
1 001 ... 1 250 mm (39.41 ... 49.21 inch)
1 251 ... 1 500 mm (49.25 ... 59.06 inch)
1 501 ... 1 750 mm (59.09 ... 68.90 inch)
¢
¢
¢
15
16
17
1 751 ... 2 000 mm (68.94 ... 78.74 inch)
2 001 ... 2 250 mm (78.78 ... 88.58 inch)
2 251 ... 2 500 mm (88.62 ... 98.43 inch)
¢
¢
¢
18
21
22
2 501 ... 2 750 mm (98.46 ... 108.27 inch)
2 751 ... 3 000 mm (108.31 ... 118.11 inch)
3 001 ... 3 250 mm (118.15 ... 127.95 inch)
¢
¢
¢
23
24
25
3 251 ... 3 500 mm (127.99 ... 137.80 inch)
3 501 ... 3 750 mm (137.83 ... 147.64 inch)
3 751 ... 4 000 mm (147.68 ... 157.48 inch)
¢
¢
¢
26
27
28
© Siemens AG 2014
Level Measurement
Point level measurement – Vibrating switches
SITRANS LVS200
Selection and Ordering data
Article No.
Selection and Ordering data
SITRANS LVS200, short fork for liquids/
solids interface
Vibrating point level switch for solids or solids
within liquid interface applications, and high load
applications with short insertion requirements
7ML5732-
Further Designs
77 7 77 - 77 A 0
Please add "-Z" to Article No. and specify Order
code(s).
Stainless steel 316L (1.4404)
Standard length, 165 mm (6.50 inch)
Add Order code Y01 and plain text:
"Insertion length ... mm"
200 ... 500 mm (7.87 ... 19.69 inch)
501 ... 750 mm (19.72 ... 29.53 inch)
751 ... 1 000 mm (29.57 ... 39.37 inch)
31
32
33
34
1 001 ... 1 250 mm (39.41 ... 49.21 inch)
1 251 ... 1 500 mm (49.25 ... 59.06 inch)
1 501 ... 1 750 mm (59.09 ... 68.90 inch)
1 751 ... 2 000 mm (68.94 ... 78.74 inch)
35
36
37
38
2 001 ... 2 250 mm (78.78 ... 88.58 inch)
2 251 ... 2 500 mm (88.62 ... 98.43 inch)
2 501 ... 2 750 mm (98.46 ... 108.27 inch)
41
42
43
2 751 ... 3 000 mm (108.31 ... 118.11 inch)
3 001 ... 3 250 mm (118.15 ... 127.95 inch)
3 251 ... 3 500 mm (127.99 ... 137.80 inch)
44
45
46
3 501 ... 3 750 mm (137.83 ... 147.64 inch)
3 751 ... 4 000 mm (147.68 ... 157.48 inch)
47
48
Material process connection/extension
Stainless steel threads 304 (1.4301),
flanges 321(1.4541), Tri-clamp 304 (1.4301)4)
Stainless steel 316L (1.4404)5)
¢
Order code
Total insertion length: Enter the total insertion length
in plain text description, max. 4 000 mm
(147.48 inch)
Y01
Stainless steel tag [100 x 45 mm (3.94 x 1.77 inch)]:
Measuring-point number/identification
(max. 27 characters); specify in plain text
Y14
Signal bulb inserted in M20 cable gland1)
A20
Adjustable sensitivity (by potentiometer) for solids/
liquids interface detection1)2)
G02
Operating Instructions
Article No.
Multi-language
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
7ML1998-5FT63
4
Spare Parts
1
Replacement Electronics Module (350 Hz)
[19 ... 230 V AC, 19 ... 55 V DC, one relay output
(SPDT)]
7ML1830-1KM
Sliding sleeve, 2" BSP (ISO 228)
7ML1830-1JM
Sliding sleeve, 2" NPT (ASME B1.20.1)
7ML1830-1JN
1)
Available with Approval option D only
2)
Available with power supply option 1 only
2
Approvals
CSA/FM Dust Ignition Proof, RCM
ATEX II 1/2 D, RCM
CSA/FM General Purpose, RCM
CE, RCM
IEC-Ex t IIIC Da/Db
¢
¢
¢
¢
1)
Available with Approval option B, D, E only
2)
Not available with extension length options 11,12, 31, 32
3)
Max. 6 bar (87psi)
4)
Available with option extension length 11 ... 28
5)
Available with option extension length 31 … 48
A
B
C
D
E
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Siemens FI 01 · 2015
4/111
© Siemens AG 2014
Level Measurement
Point level measurement – Vibrating switches
SITRANS LVS200
Selection and Ordering data
Article No.
Selection and Ordering data
SITRANS LVS200, pipe extension
Vibrating point level switch for high or low levels of
bulk solids
Extended using 1" pipe extension
(customer supplied)
7ML5733-
Further Designs
77 7 77 - 77 A 0
Please add "-Z" to Article No. and specify Order
code(s).
Total insertion length: Enter the total insertion length
in plain text description, max. 3 800 mm
(149.61 inch)
Y01
Stainless steel tag [100 x 45 mm (3.94 x 1.77 inch)]:
Measuring-point number/identification
(max. 27 characters); specify in plain text
Y14
2
Enhanced sensitivity > 5 g/l via electronics and
increased fork length to 195 mm (7.68 inch)5)
K05
3
Enhanced sensitivity < 5 g/l via electronics,
increased fork length to 195 mm (7.68 inch)
and increased aluminum fork width1)4)5)
G01
5
Adjustable sensitivity (by potentiometer) for solids/
liquids interface detection2)3)4)
G02
6
Signal bulb inserted in M20 cable gland2)
A20
Operating Instructions
Multi-language
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
Article No.
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Power supply
19 ... 230 V AC, 19 ... 55 V DC, one relay output
(SPDT)1)
19 ... 230 V AC, 19 ... 55 V DC, two relay outputs
(DPDT)1)
18 ... 50 V DC PNP1)
4
19 ... 230 V AC/DC without contact, 2-wire loop
powered1)
7 ... 9 V DC (requires NAMUR switch amplifier)
NAMUR IEC 60947-5-6, 2-wire2)
8/16 mA or 4 ... 20 mA; 12.5 ... 35 V DC, 2-wire3)
Process temperature
Up to 150 °C (302 °F)
1
4
A
Process connection
Threaded
R 1½" [(BSPT), EN 10226]
1½" NPT [(Taper), ANSI/ASME B1.20.1]
A
B
DN 100 PN 6, EN 1092-1 4)
DN 100 PN 16, EN 1092-1
C
D
2" ASME 150 lb B16.5
3" ASME 150 lb B16.5
4" ASME 150 lb B16.5
2" Tri-clamp (DN 50) ISO 2852
E
F
G
K
Process connection material
Stainless steel threads 304 (1.4301),
flanges 321 (1.4541), Tri-clamp 304 (1.4301)
Stainless steel 316L (1.4404)
Extension length
Customer supplied 1" pipe extension
Length: 300 ... 3 800 mm (11.81 ... 149.61 inch)
Application type
Dry bulk solids (125 Hz)
Liquids/solids interface (350 Hz)
Approvals
CSA/FM Dust Ignition Proof, RCM
ATEX II 1/2 D, RCM
CSA/FM General Purpose, RCM
CE, RCM
CSA/FM IS Class I, II, III Div. 1, Groups A, B, C, D,
E, F, G, FM Class 1, Aex ia IIC, CSA Class 1,
Ex ia IIC, RCM
ATEX II 1G and 1/2G Eex ia IIC; ATEX II 1D and
1/2D, RCM
IEC-Ex t IIIC Da/Db
1)
Available with Approval options A, B, C, D, G only
2)
Available with Approval options D, E and F only.
Not available for application type 2 "Liquids/solids interface".
3)
Available with Approval options B, D, G only
4)
Max. 6 bar (87 psi)
Siemens FI 01 · 2015
7ML1998-5FT63
Spare Parts
Flanged
4/112
Order code
1
2
1
1
2
A
B
C
D
E
F
H
Replacement Electronics Module (125 Hz)
[19 ... 230 V AC, 19 ... 55 V DC, one relay output
(SPDT)]
7ML1830-1KL
Replacement Electronics Module (350 Hz)
[19 ... 230 V AC, 19 ... 55 V DC, one relay output
(SPDT)]
7ML1830-1KM
Isolated switch amplifier relay output
KFD2-SR2-Ex1.W
A5E03496569
1)
Available only with power supply 1 and Approvals C, D and with
Process connection flange C … G
2)
Available with approval options D only
3)
Available with power supply option 1 only and application type 2
4)
Not available with option K05
5)
Available with Application type 1 only
© Siemens AG 2014
Level Measurement
Point level measurement – Vibrating switches
SITRANS LVS200
Selection and Ordering data
Article No.
Selection and Ordering data
Article No.
SITRANS LVS200, cable extended
Vibrating point level switch for high or low level
detection of bulk solids materials
7ML5734-
7ML5734-
7 7 7 7 7 - 77 A 0
SITRANS LVS200, cable extended
Vibrating point level switch for high or low level
detection of bulk solids materials
1
Approvals
CSA/FM Dust Ignition Proof, RCM
ATEX II 1/2 D, RCM
CSA/FM General Purpose, RCM
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Power supply
19 ... 230 V AC, 19 ... 55 V DC, one relay output
(SPDT)1)
19 ... 230 V AC, 19 ... 55 V DC, two relay outputs
(DPDT)1)
18 ... 50 V DC PNP1)
19 ... 230 V AC/DC without contact,
2-wire loop powered1)
7 ... 9 V DC (requires NAMUR switch amplifier)
NAMUR IEC 60947-5-6, 2-wire2)
8/16 mA or 4 ... 20 mA; 12.5 ... 35 V DC, 2-wire3)
Process temperature
Up to 80 °C (176 °F)
3
4
5
6
A
B
Flanged
C
D
2" ASME 150 lb B16.5 (1.4541/321)
3" ASME 150 lb B16.5 (1.4541/321)
4" ASME 150 lb B16.5 (1.4541/321)
E
F
G
Extension length
750 ... 1 000 mm (29.5 ... 39.4 inch) [max. length
20 000 mm (787.4 inch), not with Power supply
option 5 (max. 10 000 mm, 393.7 inch)]
F
G
Available with Approval options A, B, C, D, G only
2)
Available with Approval option D, E and F only.
Not available for application type 2 "Liquids/solids interface".
3)
Available with Approval option D only
4)
Max. 6 bar (87 psi)
5)
Not available with application type option 2
6)
Not available with Power supply option 5
7)
Cable length is limited to 7 000 mm (275.59 inch).
4
Order code
Further Designs
Please add "-Z" to Article No. and specify Order
code(s).
10
Add Order code Y01 and plain text:
"Insertion length ... mm"
1 001 ... 2 000 mm (39.41 ... 78.74 inch)
2 001 ... 3 000 mm (78.78 ... 118.11 inch)
3 001 ... 4 000 mm (118.15 ... 157.48 inch)
11
12
13
4 001 ... 5 000 mm (157.52 ... 196.85 inch)
5 001 ... 6 000 mm (196.89 ... 236.22 inch)
6 001 ... 7 000 mm (236.26 ... 275.59 inch)
14
15
16
inch)5)
D
E
1)
Selection and Ordering data
DN 100 PN 6, EN 1092-1 (1.4541/321)4)
DN 100 PN 16, EN 1092-1 (1.4541/321)
7 001 ... 8 000 mm (275.63 ... 314.96
8 001 ... 9 000 mm (315 ... 354.33 inch)5)
9 001 ... 10 000 mm (354.37 ... 393.70 inch)5)
17
18
20
10 001 ... 11000 mm (393.74 ... 433.07 inch)5)6)
11 001 ... 12 000 mm (433.11 ... 472.44 inch)5)6)
12 001 ... 13 000 mm (472.48 ... 511.81 inch)5)6)
21
22
23
13 001 ... 14 000 mm (511.85 ... 551.18 inch)5)6)
14 001 ... 15 000 mm (551.22 ... 590.55 inch)5)6)
15 001 ... 16 000 mm (590.59 ... 629.92 inch)5)6)
24
25
26
16 001 ... 17 000 mm (629.96 ... 669.29 inch)5)6)
17 001 ... 18 000 mm (669.33 ... 708.66 inch)5)6)
18 001 ... 19 000 mm (708.70 ... 748.03 inch)5)6)
19 001 ... 20 000 mm (748.07 ... 787.40 inch)5)6)
27
28
30
31
Application type
Dry bulk solids (125 Hz)
Liquid/solids interface (350 Hz)7)
A
B
C
CE, RCM
CSA/FM IS Class I, II, III Div. 1, Groups A, B, C, D,
E, F, G, FM Class 1, Aex ia IIC, CSA Class 1,
Ex ia IIC, RCM
ATEX II 1G and 1/2G Eex ia IIC; ATEX II 1D and
1/2D, RCM6)
IEC-Ex t IIIC Da/Db
2
A
Process connection
Threaded
R 1½" [(BSPT), EN 10226] (1.4301/304)
1½" NPT [(Taper), ANSI/ASME B1.20.1]
(1.4301/304)
7 7 7 7 7 - 77 A 0
Enter the total insertion length in plain text
description, max. 20 000 mm (787.40 inch)
Y01
Stainless steel tag [100 x 45 mm (3.94 x 1.77 inch)]:
Measuring-point number/identification
(max. 27 characters); specify in plain text
Y14
Enhanced sensitivity > 5 g/l via electronics and
increased fork length to 195 mm (7.68 inch)
K05
Enhanced sensitivity < 5 g/l via electronics and
increased fork length to 195 mm (7.68 inch) and
increased aluminum fork width1)
G01
Signal bulb inserted in M20 cable gland2)
A20
Operating Instructions
Article No.
Multi-language
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
7ML1998-5FT63
Spare Parts
Replacement Electronics Module (125 Hz)
[19 ... 230 V AC, 19 ... 55 V DC,
one relay output (SPDT)]
7ML1830-1KL
Replacement Electronics Module (350 Hz)
[19 ... 230 V AC, 19 ... 55 V DC,
one relay output (SPDT)]
7ML1830-1KM
Isolated switch amplifier relay output
KFD2-SR2-Ex1.W
A5E03496569
1)
Available only with power supply 1 and Approvals C, D and with
process connection flange C … G
2)
Available with Approval options C and D only
1
2
Siemens FI 01 · 2015
4/113
© Siemens AG 2014
Level Measurement
Point level measurement – Vibrating switches
SITRANS LVS200
150
(5.91)
Tine orientation
marking
Threaded bushing
[max. temp. 80 °C
(176 °F)]
Optional sliding
bushing*
Thread length
BSP: 20.5 (0.81)
NPT: 24 (0.94)
42 (1.67)
100 (3.94)
Solids/liquids
interface model
Tine
165 (6.5): Compact solids/ liquids interface model
230 (9.0): Compact standard version
300 ... 4 000
(11.81 ... 157): Customer-specified rigid extension
42 (1.67)
100 (3.94)
Solids/liquids
interface model
Tine
Notes:
* The clamping screws of the sliding bushing must be tightened to 10 Nm.
** Cable version with liquids/solids interface model option length to 7 000 mm (275.59 inch)
Cable version with NAMUR electronics length to 10 000 mm (393.7 inch) tightened to 10 Nm.
See drawing 23650563 for pipe extended version details. (Pipe is customer supplied.)
SITRANS LVS200, dimensions in mm (inch)
4/114
Siemens FI 01 · 2015
170 (6.69):
Standard model
4
170 (6.69):
Standard model
Customer supplied
process flange
195 (7.68)
60
(2.36)
700 ... 20 000 (27.56 ... 787)**
View A-A
A
75
(2.95)
120
(4.72)
60
(2.36)
A
155
(6.1)
■ Dimensional drawings
© Siemens AG 2014
Level Measurement
Point level measurement – Vibrating switches
SITRANS LVS200
■ Schematics
FSH/FSL adjustment
LED
Universal voltage (DPDT relay)
3-wire PNP
Sensitivity adjustment
(B=factory setting,
A=decreased sensitivity)
B
FSL
Alarm output
relay
1 2
FSH
A
1
L N
19 ... 230 V AC or
+/- 19 ... 55 V DC
PE +
L
2
N
3
4
5
7
9
8
1
2
3
Load
3 4 5
Signal output
PE + L N
AC
Terminal 1: L, terminal 2: N
19 ... 230 V AC, +10 %,
50 ... 60 Hz, 18 VA
Protective
earth
terminal
2-wire
1
2
PE +
-
DC
Terminal 1: +, terminal 2: 18 ... 50 V DC, +10 %, 1.5 W
DC
Terminal 1: +, terminal 2: 19 ... 55 V DC, +10 %, 2 W
NAMUR IEC 60947-5-6 8/16 mA or 4 ... 20 mA
AC
Terminal 1: L, terminal 2: N
19 ... 230 V AC, +10 %,
50 ... 60 Hz, 1.5 VA
DC
Terminal 1: +, terminal 2: 19 ... 230 V DC, +10 %, 1 W
1
2
1
2
DC
terminal 1: +, terminal 2: 2.5 ... 36 V DC, + 0 %
Approx. 7 ... 9 V DC,
intrinsically safe
(IEC 60947-5-6)
PE +
L
N
PE +
L
N
SITRANS LVS200 connections
Siemens FI 01 · 2015
4/115
4
© Siemens AG 2014
Level Measurement
Point level measurement – Rotation paddle switches
SITRANS LPS200
■ Overview
■ Technical specifications
Mode of operation
Measuring principle
Rotating point level switch
Input
Measured variable
High and low and demand
Output
Output signal
• Alarm output
• Pickup delay
Microswitch 5 A at 250 V AC,
non inductive
Microswitch SPDT contact 4 A at
30 V DC, non-inductive
Standard (1 rpm model):
approx 1.3 seconds
Optional process applications
(5 rpm model): approx. 0.26 seconds
4
Sensitivity
Adjustable via reset force of spring or
geometry of measuring vane
Rated operating conditions
SITRANS LPS200 is a rotary paddle switch for point level and
material detection in bulk solids.
■ Benefits
•
•
•
•
•
•
•
•
•
Proven paddle switch technology for bulk solids
High integrity mechanical seal
Optional switch selectable power supply
Unique friction clutch mechanism prevents damage from
falling material
Rotatable enclosure for convenient wiring
Optional paddles for use with low density materials
Small paddle makes for simple installation through existing
process connection
High temperature model and optional extension kit available
Optional fail-safe configuration detects loss of rotation
■ Application
The paddle switch technology detects full, empty, or demand
conditions on materials such as grain, feed, cement, plastic
granulate, and wood chips. The paddle switch can handle bulk
densities as low as 15 g/l (2.19 lb/ft3) with the optional rectangular vane or 100 g/l (6.25 lb/ft3) with the standard measuring vane.
A low revolution geared motor with slip clutch drives a rotating
measuring vane which senses the presence of material at the
mounted level of the LPS200. As material comes into contact
with the rotating paddle, rotation stops, which changes the
microswitch state. When the paddle is no longer covered
by material, rotation resumes and the relay reverts to its normal
condition.
The LPS200 has a rugged design for use in harsh conditions in
the solids industry. The sensitivity of the paddle can be adjusted
for varying material properties like buildup on the vane.
The LPS200 comes in a variety of configurations including compact, extended and cable extension. It is equipped with a standard vane which is effective in most applications, but can be
configured with a hinged or rectangular vane for increased sensitivity for light materials.
• Key Applications: bulk solids such as grain, feed, cement,
plastic granulate, wood chips
4/116
Siemens FI 01 · 2015
Installation conditions
• Location
Indoor/outdoor
Ambient conditions
• Ambient temperature
• Installation category
• Pollution degree
-25 ... +60 °C (-13 ... +140 °F)
III
2
Medium conditions
• Temperature
- Standard
- Optional
• Pressure (vessel)
- Standard
- Optional
• Minimum material density
- Standard measuring vane
- Optional measuring vane
Design
Material
• Enclosure
• Process connection,
measuring shaft and vane
Process connection
Degree of protection
Conduit entry
Power supply
• Jumper selectable
• Universal voltage (DPDT replay)
Certificates and approvals
Bulk solids
-25 ... +80 °C (-13 ... +176 °F)
-25 ... +600°C (-13 ... +1 112 °F)
Max. 0.5 bar g (7.25 psi g)
Max. 10 bar g (145 psi g)
• Can detect down to 100 g/l
(6.25 lb/ft3)
• Can detect down to15 g/l
(2.19 lb/ft3)
Epoxy coated aluminum
Stainless steel or aluminum
Thread NPT, BSP, and flange options
IP65/Type 4/NEMA 4
2 x M20x1.5 or 2 x ½" NPT
• 115 V AC, ± 15 %, 50 ... 60 Hz,
4 VA or 230 V AC, ± 15 %,
50 Hz, 6 VA, or 48 V AC, or 24 V AC
or 24 V DC, ± 15 %, 2.5 W
24 V DC ± 15 % 50 ... 60 Hz,
22...230 V, ± 10 %, max. 10 VA
•
•
•
•
•
•
CSA/FM General Purpose
CE
CSA/FM Dust Ignition Proof
ATEX II 1/2 D
RCM
IECex
© Siemens AG 2014
Level Measurement
Point level measurement – Rotation paddle switches
SITRANS LPS200
Selection and Ordering data
Article No. Ord. code
Selection and Ordering data
Article No. Ord. code
SITRANS LPS200, compact
Rotary paddle switch for level and material
detection in bulk solids. Compact design for
side or top mounted applications.
7ML5725-
SITRANS LPS200, compact
Rotary paddle switch for level and material
detection in bulk solids. Compact design for
side or top mounted applications.
7ML5725-
77 7 77 - 777 0 777
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Process temperature
Up to 80 °C (176 °F)
¢
Process pressure
Up to 0.5 bar (7.25 psi)
Up to 5 bar (72.5 psi)
Up to 10 bar (145 psi)
1
Up to 600 °C (1 112 °F)1)2)
4
Up to 80 °C (176 °F) basic version
}¢ 5
aluminum3)
Up to 80 °C (176 °F) basic version stainless }¢ 6
steel 4)
Power supply
230 V AC, 1 rev/min.
230 V AC, 1 rev/min., fail-safe
230 V AC, 5 rev/min.
230 V AC, 5 rev/min., fail-safe
115 V AC, 1 rev/min.
115 V AC, 1 rev/min., fail-safe
}¢
¢
}¢
}¢
1
2
3
Process connection material
Aluminum7)
}¢
Stainless steel, threads 303 (1.4305),
}¢
flanges 321 (1.4541), Tri-clamp 304 (1.4301)
8)
Stainless steel 316L (1.4404)
2
3
Up to 150 °C (302 °F)
Up to 250 °C (482 °F)
77 7 77 - 777 0 777
1
2
3
Extension length
100 mm (3.94 inch)9)
150 mm (5.91 inch)
200 mm (7.87 inch)
¢
}¢
¢
1
2
3
A
B
C
250 mm (9.84 inch)
300 mm (11.81 inch)
¢
¢
4
5
D
E
F
Measuring vane
Boot shaped, 35 x 106 mm (1.38 x 4.17 inch)10) }¢
Hinged vane, 65 x 200 mm (2.56 x 7.87 inch)10)11) ¢
Boot shaped, 28 x 98 mm (1.10 x 3.86 inch) ¢
A
B
C
Rectangular 50 x 150 mm (1.97 x 5.91 inch)12) ¢
Rectangular 50 x 250 mm (1.97 x 9.84 inch)12) ¢
Rectangular 98 x 150 mm (3.86 x 5.91 inch)11)12) ¢
D
E
F
Rectangular 98 x 250 mm (3.86 x 9.84 inch)11)12) ¢
G
Rectangular 50 x 98 mm (1.97 x 3.86 inch)12) ¢
H
115 V AC, 5 rev/min.
115 V AC, 5 rev/min., fail-safe
¢
G
H
48 V AC, 1 rev/min.
24 V AC, 1 rev/min.
¢
J
K
24 V DC, 1 rev/min.
24 V DC, 1 rev/min., fail-safe
¢
L
M
24 V DC, 5 rev/min.
24 V DC, 5 rev/min., fail-safe
¢
N
P
Switch selectable 230 V AC/115 V
AC/24 V DC
multi-voltage, 1 rev/min.
Switch selectable 230 V AC/115 V
AC/24 V DC
multi-voltage, 5 rev/min.
48 V AC, 1 rev/min., fail-safe
48 V AC, 5 rev/min.
48 V AC, 5 rev/min., fail-safe
24 V AC, 1 rev/min., fail-safe
24 V AC, 5 rev/min.
24 V AC, 5 rev/min., fail-safe
Universal Voltage, 1 rev/min.13)
Universal Voltage, 1 rev/min, fail-safe13)
Universal Voltage, 5 rev/min.13)
Universal Voltage, 5 rev/min, fail-safe13)
}¢
Q
¢
R
Approvals
CSA/FM Dust Ignition Proof, RCM
ATEX II 1/2 D, RCM
CSA/FM General Purpose , RCM
CE, RCM
IEC Ex ta/tb IIIC
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
J 1A
J 1B
J 1C
J 1D
J1E
J1F
J 2A
J 2B
J 2C
J 2D
¢
¢
}¢
A
B
C
1" NPT [(Taper), ANSI/ASME B1.20.1]
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
1½" NPT [(Taper), ANSI/ASME B1.20.1]
¢
}¢
¢
D
E
F
A
B
C
D
E
1)
Available with approval option C and D only, up to 0.5 bar
2)
Not available with process connection A,B, D, E and G
3)
Only available with the following configurations 7ML5725-5AC11-2AD0 or
7ML5725-5EE11-2AC0
4)
Only available with the following configurations 7ML5725-6QC12-2AB0 or
7ML5725-6QE12-2AA0
5)
Available with process pressure 1 and 2 only
6)
Available with process temperature 1 only
7)
Available with process connections A ... F only, process pressure option 1
and process temperature 1 and 5 only
8)
Available with process connection C, F, H … N and Measuring vane A
9)
Available with measuring vane option A, C, D, E, H only
10) Add
Process connection
Threaded
G 1¼" [(BSPP), EN ISO 228-1]
G 1" [(BSPP), EN ISO 228-1]
G 1½" [(BSPP), EN ISO 228-1]
}¢
}¢
}¢
}¢
4
16 mm (0.63 inch) to extension length
11) Available
with extension lengths 2, 3, 4, 5
12) Available
with process connections H … M only
13) Available
with approval option B,D, and E only
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
} Available ex stock. For details see page 9/5 in the appendix.
Flanged
DN 32 PN 6, EN 1092-15)
DN 100 PN 6, EN 1092-15)
DN 100 PN 16, EN 1092-1
G
H
J
2" ASME 150 lb B16.5
3" ASME 150 lb B16.5
4" ASME 150 lb B16.5
2" Tri-clamp (DN 50) ISO28526)
K
L
M
N
Siemens FI 01 · 2015
4/117
© Siemens AG 2014
Level Measurement
Point level measurement – Rotation paddle switches
SITRANS LPS200
Selection and Ordering data
Order code
Further Designs
Please add "-Z" to Article No. and specify Order
code(s).
4
A35
Signal bulb inserted in M20 cable gland1)
A20
Food grade materials (in contact with process),
according to 1935/2004/EC, with FDA conform
shaft sealing3)
K01
Stainless steel tag [100 x 45 mm (3.94 x 1.77 inch)]:
Measuring-point number/identification
(max. 27 characters); specify in plain text
Y14
Additional Operating Instructions
Article No.
Multi-language
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
7ML1998-5FS62
Spare Parts
Motor gear /PLC, multi-voltage
7ML1830-1KG
Replacement vane, boot shape, 35 x 106 mm
(1.38 x 4.17 inch)
7ML1830-1KH
Hinged vane, 65 x 200 mm (2.56 x 7.87 inch)
7ML1830-1KJ
Rigid extension kit
(includes spring coupling, rigid tube extension and
required pins)
Extension: 500, 400, 300 mm (19.7, 15.8, 11.8 inch)
7ML5711-0AA
Extension: 1 000, 900, 800, 700, 600 mm
(39.4, 35.4, 31.5, 27.6, 23.6 inch)
7ML5711-1AA
Extension: 1 500, 1 400, 1 300, 1 200, 1 100 mm
(59.1, 55.1, 51.2, 47.2, 43.3 inch)
7ML5711-2AA
Siemens FI 01 · 2015
Order code
Available ex stock
For details see page 9/5 in the appendix.
Heating of enclosure1)2)
4/118
Selection and Ordering data
SITRANS LPS200, compact for up to
80 °C (176 °F), aluminum, with power supply A,
process connection C, process pressure 1,
process connection material 1, extension length 2,
measuring vane A, and approval D
7ML1830-1KG
SITRANS LPS200, compact for up to 80 °C
(176 °F), aluminum, with power supply E,
process connection E, process pressure 1,
process connection material 1, extension length 2,
measuring vane A, and approval C
7ML57255EE11-2AC0
SITRANS LPS200, compact for up to 80 °C
(176 °F), stainless steel, with power supply Q,
process connection C, process pressure 1,
process connection material 2, extension length 2,
measuring vane A, and approval B
7ML57256QC12-2AB0
SITRANS LPS200, compact for up to 80 °C
(176 °F), stainless steel, with power supply Q,
process connection E, process pressure 1,
process connection material 2, extension length 2,
measuring vane A, and approval A
7ML57256QE12-2AA0
1)
Available with approval option D only
2)
Available with power supply options A ,C, E, G, J, K, L, N, J1B, J1D, J1E,
J2A, J2C only
3)
Available up to 250 °C (482 °F). This option does not automatically
implement a food conform design.
© Siemens AG 2014
Level Measurement
Point level measurement – Rotation paddle switches
SITRANS LPS200
Selection and Ordering data
Article No. Ord. code
Selection and Ordering data
Article No. Ord. code
SITRANS LPS200, shaft protected
Rotary paddle switch for level and material
detection in bulk solids; ideal for heavy,
sticky, or high impact applications.
Designed with added protection tube for
enhanced shaft protection and protection
against build-up on shaft (sidewall build-up).
7ML5726-
SITRANS LPS200, shaft protected
Rotary paddle switch for level and material
detection in bulk solids; ideal for heavy,
sticky, or high impact applications.
Designed with added protection tube for
enhanced shaft protection and protection
against build-up on shaft (sidewall build-up).
7ML5726-
77 7 77 - 7777 777
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Process temperature
Up to 80 °C (176 °F)
¢
Process pressure
Up to 0.5 bar (7.25 psi)
Up to 5 bar (72.5 psi)
Up to 10 bar (145 psi)
1
Up to 600 °C (1 112 °F)1)2)
Up to 80 °C (176 °F) basic version3)
}
4
5
Power supply
230 V AC, 1 rev/min.
¢
A
230 V AC, 1 rev/min., fail-safe
230 V AC, 5 rev/min.
¢
B
C
230 V AC, 5 rev/min., fail-safe
115 V AC, 1 rev/min.
¢
D
E
F
115 V AC, 1 rev/min., fail-safe
115 V AC, 5 rev/min.
115 V AC, 5 rev/min., fail-safe
48 V AC, 1 rev/min.
¢
¢
G
H
J
24 V AC, 1 rev/min.
24 V DC, 1 rev/min.
¢
¢
K
L
24 V DC, 5 rev/min.
24 V DC, 5 rev/min., fail-safe
¢
N
P
Switch selectable 230 V AC/115 V AC/
24 V DC
multi-voltage, 1 rev/min.
Switch selectable 230 V AC/115 V AC/
24 V DC
multi-voltage, 5 rev/min.
48 V AC, 1 rev/min., fail-safe
}¢
Q
¢
R
Z
J 1A
48 V AC, 5 rev/min.
48 V AC, 5 rev/min., fail-safe
Z
Z
J 1B
J 1C
24 V AC, 1 rev/min., fail-safe
24 V AC, 5 rev/min.
Z
Z
J 1D
J1E
24 V AC, 5 rev/min., fail-safe
Universal Voltage, 1 rev/min.14)
Z
Z
J1F
J 2A
Universal Voltage, 1 rev/min, fail-safe14)
Universal Voltage, 5 rev/min.14)
Z
Z
J 2B
J 2C
fail-safe14)
Z
J 2D
Universal Voltage, 5 rev/min,
1
2
3
1
2
3
4
Extension length
150 mm (5.91 inch)8)
200 mm (7.87 inch)
¢
}¢
1
2
250 mm (9.84 inch)
300 mm (11.81 inch)
¢
¢
3
4
Extension material (protection tube)
Aluminum9)
¢
A
}¢
B
C
Stainless steel 303 (1.4305)
Stainless steel 316L (1.4404)10)
M
24 V DC, 1 rev/min., fail-safe
}¢
Process connection material
Aluminum6)
¢
Stainless steel, threads 303 (1.4305),
}¢
flanges 321 (1.4541), Tri-clamp 304 (1.4301)
7)
Stainless steel 316L (1.4404)
2
3
Up to 150 °C (302 °F)
Up to 250 °C (482 °F)
77 7 77 - 7777 777
Measuring vane
Boot shaped 35 x 106 mm
(1.38 x 4.17 inch)11)
Hinged vane 65 x 200 mm
(2.56 x 7.87 inch)11)12)
Rectangular 50 x 150 mm
(1.97 x 5.91 inch)13)
Rectangular 50 x 250 mm
(1.97 x 9.84 inch)13)
Rectangular 98 x 150 mm
(3.86 x 5.91 inch)12)13)
Rectangular 98 x 250 mm
(3.86 x 9.84 inch)12)13)
Rectangular 50 x 98 mm
(1.97 x 3.86 inch)13)
Approvals
CSA/FM Dust Ignition Proof, RCM
ATEX II 1/2 D, RCM
CSA/FM General Purpose, RCM
CE, RCM
IEC Ex ta/tb IIIC
}¢
A
¢
B
¢
D
¢
E
¢
F
¢
G
¢
H
}¢
}¢
¢
¢
1
2
3
4
5
1)
Available with approval option 3 and 4 only and up to max 0.5 bar
2)
Not available with process connections A, C, E
3)
Only available with the following configurations 7ML5726-5QB12-2BA2 or
7ML5726-5QC12-2BA1
4)
Available with process pressure 1 and 2 only
5)
Available with process temperature 1 only
Process connection
Threaded
G 1¼" [(BSPP), EN ISO 228-1]
¢
A
6)
G 1½" [(BSPP), EN ISO 228-1]
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
}¢
}¢
B
C
Available with process connections A ... E only, available with process
pressure option 1 only, and process temperature 1 only
7)
Extension and vane will also change to 316L, only for process connection
B, D, F …L and vane A
1½" NPT [(Taper), ANSI/ASME B1.20.1]
¢
D
8)
Available with measuring vane options A, D, E, H only
9)
Available with process pressure 1 and process temperature 1 only
Flanged
DN 32 PN 6, EN 1092-14)
DN 100 PN 6, EN 1092-14)
E
F
DN 100 PN 16, EN 1092-1
G
2" ASME 150 lb B16.5
3" ASME 150 lb B16.5
4" ASME 150 lb B16.5
H
J
K
2" Tri-clamp (DN 50) ISO28525)
L
10) Available
with process connections B, D, F … L and vane A
11)
Add 16 mm (0.63 inch) to extension length
12)
Available with extension length options 2 … 4 only
13)
Available with process connections F, G, H, J, K only
14)
Available with approval options 2, 4 and 5 only
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
} Available ex stock. For details see page 9/5 in the appendix.
Siemens FI 01 · 2015
4/119
© Siemens AG 2014
Level Measurement
Point level measurement – Rotation paddle switches
SITRANS LPS200
Order code
Selection and Ordering data
Article No. Ord. code
7ML5727-
Heating of
Signal bulb inserted in M20 cable gland1)
A35
SITRANS LPS200, cable extension
Rotary paddle switch for level and material
detection in bulk solids.
Cable extension for increased length in
top-mounted applications
Food grade materials (in contact with process),
according to 1935/2004/EC, with FDA conform
shaft sealing3)
K01
Stainless steel tag [100 x 45 mm (3.94 x 1.77 inch)]:
Measuring-point number/identification
(max. 27 characters); specify in plain text
Y14
Additional Operating Instructions
Article No.
Multi-language
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
7ML1998-5FS62
Selection and Ordering data
Further Designs
Please add "-Z" to Article No. and specify Order
code(s).
enclosure1)2)
4
A20
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Process temperature
Up to 80 °C (176 °F)
Spare Parts
Motor gear /PLC, multi-voltage
7ML1830-1KG
Replacement vane, boot shape, 35 x 106 mm
(1.38 x 4.17 inch)
7ML1830-1KH
Hinged vane, 65 x 200 mm (2.56 x 7.87 inch)
7ML1830-1KJ
Available ex stock
For details see page 9/5 in the appendix.
SITRANS LPS200, extended for up to 80 °C
(176 °F), power supply Q, process connection B,
process pressure 1, process connection material 2,
extension length 2, extension material B,
measuring vane A, and approval 2
7ML57265QB12-2BA2
SITRANS LPS200, extended for up to 80 °C
(176 °F), power supply Q, process connection C,
process pressure 1, process connection material 2,
extension length 2, extension material B,
measuring vane A, and approval 1
7ML57265QC12-2BA1
Available with approval option 4 only
2)
Available with power supply options A ,C, E, G, J, K, L, N, J1B, J1D, J1E,
J2A, J2C only
3)
Available up to 250 °C (482 °F). This option does not automatically
implement a food conform design.
¢
1
Up to 150 °C (302 °F)
Up to 250 °C (482 °F)
2
3
Up to 600 °C (1 112 °F)1)2)
Up to 80 °C (176 °F) basic version3)
4
5
Power supply
230 V AC, 1 rev/min.
¢
A
230 V AC, 1 rev/min., fail-safe
230 V AC, 5 rev/min.
¢
B
C
230 V AC, 5 rev/min., fail-safe
115 V AC, 1 rev/min.
¢
D
E
F
115 V AC, 1 rev/min., fail-safe
115 V AC, 5 rev/min.
115 V AC, 5 rev/min., fail-safe
48 V AC, 1 rev/min.
24 V AC, 1 rev/min.
24 V DC, 1 rev/min.
1)
77777 - 777 777
¢
¢
G
H
J
¢
K
L
M
24 V DC, 1 rev/min., fail-safe
24 V DC, 5 rev/min.
24 V DC, 5 rev/min., fail-safe
¢
N
P
Switch selectable 230 V AC/115 V AC/
24 V DC multi-voltage, 1 rev/min.
Switch selectable 230 V AC/115 V AC/
24 V DC multi-voltage, 5 rev/min.
48 V AC, 1 rev/min., fail-safe
¢
Q
¢
R
Z
J1A
48 V AC, 5 rev/min.
48 V AC, 5 rev/min., fail-safe
Z
Z
J1B
J1C
24 V AC, 1 rev/min., fail-safe
24 V AC, 5 rev/min.
Z
Z
J1D
J1E
24 V AC, 5 rev/min., fail-safe
Universal Voltage, 1 rev/min.9)
Z
Z
J1F
J2A
Universal Voltage, 1 rev/min, fail-safe9)
Universal Voltage, 5 rev/min.9)
Z
Z
J2B
J2C
Universal Voltage, 5 rev/min, fail-safe9)
Z
J2D
Process connection
Threaded
G 1¼" [(BSPP), EN ISO 228-1]
¢
A
G 1½" [(BSPP), EN ISO 228-1]
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
¢
¢
B
C
1½" NPT [(Taper), ANSI/ASME B1.20.1]
¢
D
Flanged
4/120
Siemens FI 01 · 2015
DN 32 PN 6, EN 1092-14)
DN 100 PN 6, EN 1092-14)
E
F
DN 100 PN 16, EN 1092-1
G
2" ASME 150 lb B16.5
3" ASME 150 lb B16.5
4" ASME 150 lb B16.5
H
J
K
© Siemens AG 2014
Level Measurement
Point level measurement – Rotation paddle switches
SITRANS LPS200
Selection and Ordering data
Article No. Ord. code
Selection and Ordering data
SITRANS LPS200, cable extension
Rotary paddle switch for level and material
detection in bulk solids.
Cable extension for increased length in
top-mounted applications
7ML5727-
Further Designs
77777 - 777 777
Please add "-Z" to Article No. and specify Order
code(s).
Process pressure
Up to 0.5 bar (7.25 psi)
Up to 5 bar (72.5 psi)
Up to 10 bar (145 psi)
Process connection material
Aluminum5)
Stainless steel, threads 303 (1.4305),
flanges 321 (1.4541)
Cable extension length
Standard cable length, 2 000 mm
(78.74 inch)
Add Order code Y01 and plain text:
"Insertion length ... mm"
500 ... 1 000 mm (19.69 ... 39.37 inch)
Cable length 1 001 ... 2 000 mm
(39.41 ... 78.74 inch)
Cable length 2 001 ... 3 000 mm
(78.78 ... 118.11 inch)
Cable length 3 001 ... 4 000 mm
(118.15 ... 157.48 inch)
Cable length 4 001 ... 5 000 mm
(157.52 ... 196.85 inch)
Cable length 5 001 ... 6 000 mm
(196.89 ... 236.22 inch)
Cable length 6 001 ... 7 000 mm
(236.26 ... 275.59 inch)
Cable length 7 001 ... 10 000 mm
(275.63 ... 393.70 inch)
Without extension8)
Measuring vane
Boot shaped, 35 x 106 mm
(1.38 x 4.17 inch)6)
Hinged vane, 65 x 200 mm
(2.56 x 7.87 inch)6)
Boot shaped, 28 x 98 mm
(1.10 x 3.86 inch)7)
Rectangular 50 x 150 mm
(1.97 x 5.91 inch)7)
Rectangular 50 x 250 mm
(1.97 x 9.84 inch)7)
Rectangular 98 x 150 mm
(3.86 x 5.91 inch)7)
Rectangular 50 x 98 mm
(1.97 x 3.86 inch)7)
Approvals
CSA/FM Dust Ignition Proof, RCM
ATEX II 1/2 D, RCM
CSA/FM General Purpose, RCM
CE, RCM
IEC Ex ta/tb IIIC
¢
¢
¢
1
2
3
1
2
¢
0
Order code
Total insertion length:
Enter the total insertion length in plain text
description, max. 10 000 mm (393.70 inch)
Y01
Stainless steel tag [100 x 45 mm (3.94 x 1.77 inch)]:
Measuring-point number/identification
(max. 27 characters); specify in plain text
Y14
Reinforced cable (max. 28 kN pulling force)1)
P01
Heating of enclosure2)3)
A35
Signal bulb inserted in M20 cable gland2)
A20
Food grade materials (in contact with process),
according to 1935/2004/EC, with FDA conform
shaft sealing4)
K01
Additional Operating Instructions
Article No.
Multi-language
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
7ML1998-5FS62
¢
¢
1
2
¢
3
¢
4
Motor gear /PLC, multi-voltage
7ML1830-1KG
¢
5
Replacement vane, boot shape, 35 x 106 mm
(1.38 x 4.17 inch)
7ML1830-1KH
¢
6
Hinged vane, 65 x 200 mm (2.56 x 7.87 inch)
7ML1830-1KJ
Rope extension kit, 2 m (6.56 ft)
7ML1830-1KK
¢
7
¢
8
Spare Parts
Available ex stock
For details see page 9/5 in the appendix.
9
N1A
¢
A
¢
B
¢
C
¢
D
¢
E
¢
F
¢
G
¢
¢
¢
¢
A
B
C
D
E
1)
Available with approval option C and D up to max. 0.5 bar
2)
Not available with process connections A, C, E
3)
Only available with the following configurations 7ML5727-5QC12-0AA0 or
7ML5727-5QB12-0AB0
4)
Available with process pressure 1 and 2 only
5)
Available with process connections A ... E only, process pressure option 1
only and process temperature options 1 and 5 only
6)
Add 16 mm (0.63 inch) to extension length
7)
Available with process connections F … K only
8)
Not available with P01 and available with Approval D, mounting kit for rope
extension included
9)
Available with approval options B,D, and E only
SITRANS LPS200, cable extension for up to 80 °C
(176 °F), power supply Q, process connection B,
process pressure 1, process connection material 2,
extension length 0, measuring vane A,
and approval B
7ML57275QB12-0AB0
SITRANS LPS200, cable extension for up to 80 °C
(176 °F), power supply Q, process connection C,
process pressure 1, process connection material 2,
extension length 0, measuring vane A,
and approval A
7ML57275QC12-0AA0
1)
Available only for process temperature up to 80 °C (176 °F) and process
connection material 2
2)
Available with approval option D only
3)
Available with power supply options A ,C, E, G, J, K, L, N, J1B, J1D, J1E,
J2A, J2C only
4)
Available up to 250 °C (482 °F). This option does not automatically
implement a food conform design
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Siemens FI 01 · 2015
4/121
4
© Siemens AG 2014
Level Measurement
Point level measurement – Rotation paddle switches
SITRANS LPS200
Selection and Ordering data
Article No. Ord. code
Selection and Ordering data
Article No. Ord. code
SITRANS LPS200, angled extension
Rotary paddle switch with robust design for
level and material detection in bulk solids;
ideal for heavy or sticky applications.
Angled extension is designed to avoid falling
material and rotates horizontally in side mount
applications to continue working even with
heavy build-up.
7ML5728-
SITRANS LPS200, angled extension
Rotary paddle switch with robust design for
level and material detection in bulk solids;
ideal for heavy or sticky applications.
Angled extension is designed to avoid falling
material and rotates horizontally in side mount
applications to continue working even with
heavy build-up.
7ML5728-
7 7 7 77 - 77 7 0 777
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Process temperature
Up to 80 °C (176 °F)
Up to 150 °C (302 °F)
Up to 250 °C (482 °F)
4
7 7 7 77 - 77 7 0 777
Measuring vane
Rectangular vane, 50 x 98 mm
(1.97 x 3.86 inch)
Rectangular vane, 50 x 150 mm
(1.97 x 5.91 inch)
Rectangular vane, 50 x 250 mm
(1.97 x 9.84 inch)
1
2
3
A
B
C
Power supply
230 V AC, 1 rev/min.
230 V AC, 1 rev/min., fail-safe
230 V AC, 5 rev/min.
A
B
C
Rectangular vane 98 x 150 mm
(3.86 x 5.91 inch)
Rectangular vane 98 x 250 mm
(3.86 x 9.84 inch)
D
230 V AC, 5 rev/min., fail-safe
115 V AC, 1 rev/min.
115 V AC, 1 rev/min., fail-safe
D
E
F
Hinged vane, 65 x 200 mm
(2.56 x 7.87 inch)
F
115 V AC, 5 rev/min.
115 V AC, 5 rev/min., fail-safe
48 V AC, 1 rev/min.
24 V AC, 1 rev/min.
24 V DC, 1 rev/min.
24 V DC, 1 rev/min., fail-safe
G
H
J
K
L
M
24 V DC, 5 rev/min.
24 V DC, 5 rev/min., fail-safe
Switch selectable 230 V AC/115 V AC/24 V DC
multi-voltage, 1 rev/min.
N
P
Q
Switch selectable 230 V AC/115 V AC/24 V DC
multi-voltage, 5 rev/min.
48 V AC, 1 rev/min., fail-safe
R
Z
J 1A
Further Designs
Please add "-Z" to Article No. and specify Order
code(s).
48 V AC, 5 rev/min.
Z
J 1B
Heating of enclosure1)2)
A35
48 V AC, 5 rev/min., fail-safe
24 V AC, 1 rev/min., fail-safe
Z
Z
J 1C
J 1D
Signal bulb inserted in M20 cable gland1)
A20
K01
24 V AC, 5 rev/min.
Z
J1E
Food grade materials (in contact with process),
according to 1935/2004/EC, with FDA conform
shaft sealing3)
24 V AC, 5 rev/min., fail-safe
Universal Voltage, 1 rev/min.2)
Z
Z
J1F
J 2A
Y14
Universal Voltage, 1 rev/min, fail-safe2)
Z
J 2B
Stainless steel tag [100 x 45 mm
(3.94 x 1.77 inch)]: Measuring-point number/
identification (max. 27 characters); specify in
plain text
Z
Z
J 2C
J 2D
Additional Operating Instructions
Article No.
Multi-language
This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick
Start and Operating Instructions library.
7ML1998-5FS62
rev/min.2)
Universal Voltage, 5
Universal Voltage, 5 rev/min, fail-safe2)
Process connection
Flanged
DN 100 PN 6, EN 1092-11)
DN 100 PN 16, EN 1092-1
4" ASME 150 lb B16.5
Process pressure
Up to 0.5 bar (7.25 psi)
Up to 5 bar (72.5 psi)
Up to 10 bar (145 psi)
Process connection material
Stainless steel 303/321 (1.4305/1.4541)
Approvals
CSA/FM Dust Ignition Proof, RCM
ATEX II 1/2 D, RCM
CSA/FM General Purpose, RCM
CE, RCM
IEC Ex ta/tb IIIC
A
B
C
Available with process pressure 1 and 2 only
2)
Available with approval option B,D, and E only
A
B
C
D
E
Order code
Spare Parts
1
2
3
1
1
2
3
250 mm (9.84 inch)
300 mm (11.81 inch)
4
5
Siemens FI 01 · 2015
1)
Selection and Ordering data
Extension length
125 mm (4.92 inch)
150 mm (5.91 inch)
200 mm (7.87 inch)
4/122
E
Motor gear /PLC, multi-voltage
7ML1830-1KG
Replacement vane, boot shape, 35 x 106 mm
(1.38 x 4.17 inch)
7ML1830-1KH
Hinged vane, 65 x 200 mm (2.56 x 7.87 inch)
7ML1830-1KJ
1)
Available with approval option D only
2)
Available with power supply options A ,C, E, G, J, K, L, N, J1B, J1D, J1E,
J2A, J2C only
3)
This option does not automatically implement a food conform design
© Siemens AG 2014
Level Measurement
Point level measurement – Rotation paddle switches
SITRANS LPS200
Selection and Ordering data
Article No. Ord. code
Selection and Ordering data
Article No. Ord. code
SITRANS LPS200, rigid extension
Rotary paddle switch for top mount point level
and material detection in bulk solids
7ML5730-
SITRANS LPS200, rigid extension
Rotary paddle switch for top mount point level
and material detection in bulk solids
7ML5730-
77777 - 7777 777
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Process temperature
Up to 80 °C (176 °F)
Up to 150 °C (302 °F)
¢ 1
2
230 V AC, 5 rev/min., fail-safe
115 V AC, 1 rev/min.
115 V AC, 1 rev/min., fail-safe
115 V AC, 5 rev/min.
115 V AC, 5 rev/min., fail-safe
48 V AC, 1 rev/min.
24 V AC, 1 rev/min.
24 V DC, 1 rev/min.
24 V DC, 1 rev/min., fail-safe
¢
¢
¢
¢
¢
¢
¢
¢
Process connection material
Aluminum5)
Stainless steel, threads 303 (1.4305),
flanges 321 (1.4541), Tri-clamp 304 (1.4301)
Stainless steel 316L (1.4404)6)
3
4
Up to 250 °C (482 °F)
Up to 600 °C (1 112 °F)1)2)
Power supply
230 V AC, 1 rev/min.
230 V AC, 1 rev/min., fail-safe
230 V AC, 5 rev/min.
Process pressure
Up to 0.5 bar (7.25 psi)
Up to 5 bar (72.5 psi)
Up to 10 bar (145 psi)
A
B
C
Extension material (protection tube)
Aluminum7)8)
Stainless steel 303 (1.4305)9)
Stainless steel 316L (1.4404)10)11)
D
E
F
G
H
J
K
L
M
77777 - 7777 777
¢
¢
1
2
3
1
2
3
¢
¢
0
1
2
Extension length
Aluminum
250 ... 500 mm (9.84 ... 19.69 inch)
501 ... 750 mm (19.72 ... 29.53 inch)
751 ... 1 000 mm (29.57 ... 39.37 inch)
¢
¢
¢
A
B
C
1 001 ... 1 250 mm (39.41 ... 42.21 inch)
1 251 ... 1 500 mm (49.25 ... 59.06 inch)
1 501 ... 1 750 mm (59.09 ... 68.90 inch)
¢
¢
¢
D
E
F
1 751 ... 2 000 mm (68.94 ... 78.74 inch)
2 001 ... 2 250 mm (78.78 ... 88.58 inch)
2 251 ... 2 500 mm (88.62 ... 98.43 inch)
¢
¢
¢
G
H
J
¢
¢
¢
K
L
M
¢
N
P
Switch selectable 230 V AC/115 V AC/24 V DC ¢
multi-voltage, 1 rev/min.
Switch selectable 230 V AC/115 V AC/24 V DC ¢
multi-voltage, 5 rev/min.
48 V AC, 1 rev/min., fail-safe
Q
Z
J 1A
2 501 ... 2 750 mm (98.46 ... 108.27 inch)
2 751 ... 3 000 mm (108.31 ... 118.11 inch)
3 001 ... 3 250 mm (118.15 ... 127.95 inch)
48 V AC, 5 rev/min.
48 V AC, 5 rev/min., fail-safe
24 V AC, 1 rev/min., fail-safe
Z
Z
Z
J 1B
J 1C
J 1D
3 251 ... 3 500 mm (127.99 ... 137.80 inch)
3 501 ... 3 750 mm (137.83 ... 147.64 inch)
3 751 ... 4 000 mm (147.67 ... 157.48 inch)
¢
¢
¢
N
P
Q
24 V AC, 5 rev/min.
24 V AC, 5 rev/min., fail-safe
Universal Voltage, 1 rev/min.14)
Z
Z
Z
J 1E
J1F
J 2A
Universal Voltage, 1 rev/min, fail-safe14)
Universal Voltage, 5 rev/min.14)
Universal Voltage, 5 rev/min, fail-safe14)
Z
Z
Z
J 2B
J 2C
J 2D
Stainless steel 303 (1.4305)
250 ... 500 mm (9.84 ... 19.69 inch)
501 ... 750 mm (19.72 ... 29.53 inch)
751 ... 1 000 mm (29.57 ... 39.37 inch)
¢
¢
¢
R
S
T
1 001 ... 1 500 mm (39.41 ... 59.05 inch)
1 501 ... 2 000 mm (59.09 ... 78.74 inch)
2 001 ... 2 500 mm (78.78 ... 98.42 inch)
¢
¢
¢
U
V
W
2 501 ... 3 000 mm (98.46 ... 118.11 inch)
3 001 ... 4 000 mm (118.15 ... 157.48 inch)
¢
¢
X
Y
24 V DC, 5 rev/min.
24 V DC, 5 rev/min., fail-safe
Process connection
Threaded
G 1¼" [(BSPP), EN ISO 228-1]
G 1½" [(BSPP), EN ISO 228-1]
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
1½" NPT [(Taper), ANSI/ASME B1.20.1]
¢
¢
¢
¢
R
A
B
C
D
Flanged
Stainless steel 316L (1.4404)
250 ... 500 mm (9.84 ... 19.69 inch)
501 ... 750 mm (19.72 ... 29.53 inch)
751 ... 1 000 mm (29.57 ... 39.37 inch)
DN 32 PN 6, EN 1092-13)
DN 100 PN 6, EN 1092-13)
DN 100 PN 16, EN 1092-1
E
F
G
1 001 ... 1 500 mm (39.41 ... 59.05 inch)
1 501 ... 2 000 mm (59.09 ... 78.74 inch)
2 001 ... 2 500 mm (78.78 ... 98.42 inch)
2" ASME 150 lb B16.5
3" ASME 150 lb B16.5
4" ASME 150 lb B16.5
2" Tri-clamp 2’ (DN 50) ISO28524)
H
J
K
L
2 501 ... 3 000 mm (98.46 ... 118.11 inch)
3 001 ... 4 000 mm (118.5 ... 157.48 inch)
Siemens FI 01 · 2015
4
Z
Z
Z
Z
P 1A
P 1B
P 1C
P 1D
Z
Z
P1E
P1F
P 1G
Z
Z
P 1H
4/123
© Siemens AG 2014
Level Measurement
Point level measurement – Rotation paddle switches
SITRANS LPS200
4
Selection and Ordering data
Article No. Ord. code
Selection and Ordering data
SITRANS LPS200, rigid extension
Rotary paddle switch for top mount point level
and material detection in bulk solids
7ML5730-
Further Designs
Please add "-Z" to Article No. and specify Order
code(s).
77777 - 7777 777
Measuring vane
Boot shaped, 35 x 106 mm (1.34 x 4.17 inch)12) ¢
Hinged vane, 60 x 200 mm (2.36 x 7.87 inch)12) ¢
Rectangular 50 x 150 mm (1.97 x 5.91 inch)13) ¢
A
B
C
Rectangular 50 x 250 mm (1.97 x 9.84 inch)13)
Rectangular 98 x 150 mm (3.86 x 5.91 inch)13)
Rectangular 98 x 250 mm (3.86 x 9.84 inch)13)
Rectangular 50 x 98 mm (1.97 x 3.86 inch)13)
D
E
F
G
Approvals
CSA/FM Dust Ignition Proof, RCM
ATEX II 1/2 D, RCM
CSA/FM General Purpose, RCM
CE, RCM
IEC Ex ta/tb IIIC
¢
¢
¢
¢
¢
¢
¢
¢
1
2
3
4
5
Order code
Total insertion length: Enter the total insertion length
in plain text description, max. 4 000 mm
(157.48 inch)
Y01
Stainless steel tag [100 x 45 mm (3.94 x 1.77 inch)]:
Measuring-point number/identification
(max. 27 characters); specify in plain text
Y14
Heating of enclosure1)2)
A35
Signal bulb inserted in M20 cable gland1)
A20
Food grade materials (in contact with process),
according to 1935/2004/EC, with FDA conform
shaft sealing3)4)
K01
Seal at tube end for ingress protection and
shaft stability
1)
Available with approval option 3 and 4, up to max 0.5 bar
Max. temperature 80 °C (176 °F)
P06
2)
Not available with process connection A, C, E
Max. temperature 150 °C (302 °F)
P07
3)
Available with process pressure 1 and 2 only
4)
Max. temperature 250 °C (482 °F)
P08
Available with process temperature 1 only
Max. temperature 600 °C (1 112 °F)
P09
Sliding sleeve (standard, max. pressure 0.5 bar)1)5)
P12
P13
5)
Available with process connections A ... E only, with process pressure
option 1 only and process temperature 1 only
6)
Available with process connection B, D, F … L and measuring vane
option A
7)
Available with process pressure 1 and process temperature 1 only
Sliding sleeve (pressure tight, for over-pressure
application starting from 1 bar max., dependent on
pressure option ordered)6)
8)
Available with extension length options A … Q only
Additional Operating Instructions
Article No.
9)
Available with extension length options R … Y only
Multi-language
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
7ML1998-5FS62
10) Available
with process connection B, D, F …L and measuring vane A,
process connection material 3. Available only with extension length options
P1A … P1H only
11) Only
available with seal at tube end, option P06 … P09
12) Add
16 mm (0.63 inch) to extension length
13) Available
14) Available
with process connections F, G, H, J, K only
with approval options 2, 4 and 5 only
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix
4/124
Siemens FI 01 · 2015
Spare Parts
Motor gear/PLC, multi-voltage
7ML1830-1KG
Replacement vane, boot shape, 35 x 106 mm
(1.38 x 4.17 inch)
7ML1830-1KH
Hinged vane, 65 x 200 mm (2.56 x 7.87 inch)
7ML1830-1KJ
1)
Available with approval option 4 only
2)
15) Available with power supply options A ,C, E, G, J, K, L, N, J1B, J1D,
J1E, J2A, J2C only
3)
Available when ordered with ingress protection seal P06 … P09 only
4)
Available up to 250 °C (482 °F). This option does not automatically
implement a food conform design
5)
Available with process pressure 1 only
6)
Available up to 250 °C (482 °F)
© Siemens AG 2014
Level Measurement
Point level measurement – Rotation paddle switches
SITRANS LPS200
■ Dimensional drawings
Standard model: compact version
High temperature model: compact version
75 (2.95)
600 °C
(1 112 ºF)
400
(15.74)
1)
L
Optional
process
flange
L= Length
150 (5.91)
Shaft protected
option
1)
Process temperature 2)
-25 ... +600 °C
(-13 ... +428 °F)
250 (9.84)
300 (11.81)
Angle option
L
1)
125 ... 300
(4.92 ... 8.46)
Measuring vane
Rope option
Rope
fixing
Measuring vanes
35 (1.38)
106
(4.17)
Rectangular
Hinged
Fold
together
to lead
into
mounting
hole
50 (1.97)
50 (1.97)
A
Min. 37
(1.46)
Rectangular vane options
A
B
65
(2.56)
Standard
210 (8.27)
Vane
B
98 (3.86)
150 (5.90)
50 (1.97)
250 (9.84)
98 (3.86)
150 (5.90)
98 (3.86)
250 (9.84)
1. For 35 x 106 mm boot shaped and 65 x 210 mm hinged
measuring vanes, add 16 mm to extension length.
2. For use with all approval options except CSA class II. See
manual for more details.
Notes
For heavy material, only top mounting of paddle switch is
recommended.
Compact LPS200 is recommended for side mounting on bins
for low or intermediate material levels.
4
200 (7.87)
2 000 (78.74) standard;
Can be shortened by the customer;
total length available 10 000 (393.7)
Zone 20
(Cat. 1)
Thread length
BSP: 20.5 (0.81)
NPT: 24 (0.94)
200
(7.87)
100 (3.94)
Zone 20
(Cat. 1)
L
123
(4.84)
Zone 21
(Cat. 2)
A
150/250 °C
(302/482 ºF)
Zone 21
(Cat. 2)
120 (4.72)
Process temperature
-25 ... +80 °C
(-13 ... +176 °F)
A
Ambient temperature
-25 ... +60 °C
(-13 ... +140 °F)
60 (2.36)
Ambient temperature
-25 ... +60 °C
(-13 ... +140 °F)
Process
temperature
Thread length
BSP: 20.5 (0.81)
NPT: 24 (0.94)
60 (2.36)
Conduit connection
M20 or ½" NPT
Completely covered
with material
Covered up to 10 cm (3.93 inch)
with material
Spring adjustment
Spring adjustment
Light
boot shaped
35 x 106 mm
boot shaped
28 x 98 mm
rectangular
50 x 98 mm
rectangular
50 x 150 mm
rectangular
50 x 250 mm
rectangular
98 x 150 mm
rectangular
98 x 250 mm
hinged
65 x 210 mm
hinged
60 x 200 mm
200 g/l
(12.5 lb/ft³)
300 g/l
(18.7 lb/ft³)
300 g/l
(18.7 lb/ft³)
80 g/l
(5.0 lb/ft³)
30 g/l
(1.9 lb/ft³)
30 g/l
(1.9 lb/ft³)
20 g/l
(1.2 lb/ft³)
70 g/l
(4.4 lb/ft³)
70 g/l
(4.4 lb/ft³)
Central
(factory setting)
300 g/l
(18.7 lb/ft³)
500 g/l
(31.2 lb/ft³)
500 g/l
(31.2 lb/ft³)
120 g/l
(7.5 lb/ft³)
50 g/l
(3.1 lb/ft³)
50 g/l
(3.1 lb/ft³)
30 g/l
(1.9 lb/ft³)
100 g/l
(6.2 lb/ft³)
100 g/l
(6.2 lb/ft³)
Light
100 g/l
(6.2 lb/ft³)
150 g/l
(9.4 lb/ft³)
150 g/l
(9.4 lb/ft³)
40 g/l
(2.5 lb/ft³)
15 g/l
(0.9 lb/ft³)
15 g/l
(0.9 lb/ft³)
15 g/l
(0.9 lb/ft³)
35 g/l
(2.2 lb/ft³)
35 g/l
(2.2 lb/ft³)
Central
(factory setting)
150 g/l
(9.4 lb/ft³)
150 g/l
(9.4 lb/ft³)
250 g/l
(15.6 lb/ft³)
60 g/l
(3.7 lb/ft³)
25 g/l
(1.6 lb/ft³)
25 g/l
(1.6 lb/ft³)
15 g/l
(0.9 lb/ft³)
50 g/l
(3.1 lb/ft³)
50 g/l
(3.1 lb/ft³)
SITRANS LPS200, dimensions in mm (inch)
Siemens FI 01 · 2015
4/125
© Siemens AG 2014
Level Measurement
Point level measurement – Rotation paddle switches
SITRANS LPS200
■ Schematics
AC or DC version, SPDT, fail-safe
8
7
6
5
1
2
L
+
N PE
-
Switching and timing behaviour:
If the vane is not covered, the rotating vane
shaft will send pulses at 20 second intervals.
In case of fault, the pulses are missed. After
30 seconds, the alarm relay will open.
24 V or 48 V or 115 V or 230 V AC, 50/60 Hz, 5 VA
4
Alarm
output
Signal
output
OR
24 V DC, 2.5 W All voltages ± 15 %
Voltage selector
AC version DPDT FSH/FSL
Universal voltage (DPDT relay)
24 V
max. 4 mm 2
(AWG12)
max. 4 mm 2
(AWG12)
115 V
230 V
8
9 10
7
6
Signal output DPDT
5
1
2
8
L N PE
+ Power Supply
9 10
7
6
Signal output
DPDT
2)
5
4
Alarm
output2)
1 2
L N PE
+ Power Supply
With option Fail safe alarm (rotation control)
Contact open when de-energised
SITRANS LPS200 connections
4/126
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Point level measurement – Ultrasonic non-contacting switch
Pointek ULS200
■ Overview
■ Application
The measuring range for bulk solids is max. 3 m (9.8 ft) and 5 m
(16.4 ft) for liquids and slurries. Unlike invasive contacting
devices, there is no material buildup on the sensor.
The level switch has a rugged design, combining the transducer
and electronics in one durable device. It has no moving parts
and is virtually maintenance-free.
The transducer, available in ETFE or PVDF copolymer, is inert to
most chemicals. This means the device can be used in the
chemical, petrochemical, water, and wastewater industries.
A sanitary version of the ULS200, with an industry standard
flange option, is easy to remove from the application for
cleaning. It thus satisfies the prerequisites for use in the food,
beverage, and pharmaceutical industries. The Pointek ULS200
delivers superior performance while reducing maintenance,
downtime, and equipment replacement costs.
• Key Applications: liquids, slurries, fluid materials, plugged
chute detection, chemical industry
The Pointek ULS200 is an ultrasonic non-contacting switch with
two switch points for level detection of bulk solids, liquids and
slurries in a wide variety of industries; ideal for sticky materials.
■ Benefits
• 2 switch outputs for high-high, high, low and low-low level
alarms or pump up/pump down control
• Integral temperature compensation
• AC or DC power supply
• Electronics provided with fail-safe function
• Threaded and sanitary fitting clamp process connections
• Polycarbonate enclosure, Type 6/NEMA 6/IP67
• Easy, two-button programming
■ Design
Installation
The Pointek ULS200 should be mounted in an area that is within
the temperature range specified and that is suitable to the enclosure rating and materials of construction. The cover should be
accessible to allow programming, wiring and display viewing.
It is advisable to keep the Pointek ULS200 away from high voltage or current runs, contactors and SCR control drives.
Locate the Pointek ULS200 so that it has a clear sound path
perpendicular to the material surface. The sound path should
not intersect the fill path, rough walls, seams, rungs etc.
Mounting and Interconnection
The Pointek ULS200 is available in three thread types: 2" NPT,
R 2" (BSPT), EN 10226 or PF2 and can be fitted with the optional
75 mm (3 inch) flange adapter for mating to 3" ASME, DN 65,
PN 10, and JIS 10K 3B sized flanges.
Separate cables and conduit may be required to conform to
standard instrumentation wiring or electrical codes.
Siemens FI 01 · 2015
4/127
4
© Siemens AG 2014
Level Measurement
Point level measurement – Ultrasonic non-contacting switch
Pointek ULS200
■ Configuration
Parabolic mounting
4
Flat mounting and Beam angle
Fill
Pipe
Rungs
Seams
12°
Beam angle
Pointek ULS200 Mounting
4/128
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Point level measurement – Ultrasonic non-contacting switch
Pointek ULS200
■ Technical specifications
Mode of operation
Measuring principle
Electronics/enclosure
Connection: terminal block,
max. 2.5 mm2 (14 AWG) solid/
1.5 mm2 (16 AWG) stranded
Ultrasonic level switch
Measuring range
Degree of protection
IP67/Type 6/NEMA 6
Measuring range in liquids
0.25 ... 5 m (0.8 ... 16.4 ft)
Cable inlet
2 x ½" NPT or 2 x PG 13.5
Measuring range in bulk solids
0.25 ... 3 m (0.8 ... 9.8 ft)
Certificates and approvals
• CE (EMC certificate available on
request), CSA US/C, FM
Output
AC Version (relay)
2 SPDT Form C contacts, rated 5 A at
250 V AC or 30 V DC, resistive load;
rated 1 A at 48 V DC resistive load
DC Version (relay)
2 SPDT Form C contacts, rated 5 A
at 30 V DC, resistive load; rated 1 A
at 48 V DC resistive load
DC Version (transistor)
Flange adapter for mating 2" NPT or 2" BSP process connections to 3"
ASME, DN 65 PN 10 and JIS 10K 3B flanges
2 switches, rated max. 100 mA, 48 V DC
148.8 (5.86)
Bolt hole circle
diameter
Accuracy
AC/DC version
• Resolution
• Repeatability
■ Options
4
3 mm (0.1 inch)
0.25 % of measuring range
Rated operation conditions
Installation conditions
• Location
• Beam angle
Indoors/outdoors
12°
Ambient conditions
• Ambient temperature
• If mounted in metal threads
-40 ... +60 °C (-40 ... +140 °F)
-20 ... +60 °C (-5 ... +140 °F)
Medium conditions
• Process pressure
0.5 bar (7.25 psi) max.
190.2 (7.49)
Diameter
Pointek ULS200 Optional Flange Adapter, dimensions in mm (inch)
Design
Material
Polycarbonate with gasket
Weight
Approx. 1.5 kg (3.3 lb)
Transducer material
PVDF or ETFE copolymer
Threaded mounting
2" NPT
[(Taper), ANSI/ASME B1.20.1]
R 2" [(BSPT), EN 10226]
or G 2" [(BSPP), EN ISO 228-1]
For 3" ASME, DN 65, PN 10 and
JIS 10 K3B
• Optional flange adapter
Sanitary mounting
4" sanitary fitting clamp
Power supply
AC version
100 ... 230 V AC, ± 15 %, 50/60 Hz,
max. 12 VA, 5 W
DC version
18 ... 30 V DC, 3 W
Displays and controls
Display
LCD, three digits, 9 mm (0.35 inch)
high for display of distance between
sensor face and material, multi-segment
graphic for operating state
Memory
EEPROM, non-volatile
Programming
2 keys
Siemens FI 01 · 2015
4/129
© Siemens AG 2014
Level Measurement
Point level measurement – Ultrasonic non-contacting switch
Pointek ULS200
Selection and Ordering data
Article No.
Selection and Ordering data
Pointek ULS200
Ultrasonic non-contacting switch with two switch
points for level detection of bulk solids, liquids and
slurries in a wide variety of industries; ideal for
sticky materials
7ML1510-
Further designs
Please add "-Z" to Article No. and specify Order
code(s)
777 0 7
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Measuring-point number/identification
(max. 27 characters) specify in plain text
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Power supply
24 V DC, relay output
24 V DC, transistor output
100 ... 230 V AC, relay output
¢ 1
¢ 2
¢ 3
¢
¢
Transducer/Process connection
ETFE, 2" NPT [(Taper), ANSI/ASME B1.20.1]
EFTE, R 2" [(BSPT), EN 10226]
EFTE, G 2" [(BSPP), EN ISO 228-1]
¢
¢
¢
A
B
C
PVDF copolymer, 2" NPT [(Taper), ANSI/ASME B1.20.1] ¢
PVDF copolymer, R 2" [(BSPT), EN 10226]
¢
PVDF copolymer, G [(BSPP), EN ISO 228-1]
¢
PVDF copolymer, 4" sanitary
Enclosure/cable inlet
Polycarbonate
• Cable inlet PG 13.5
• Cable inlet ½" NPT
1)
Available with Enclosure/cable inlet option 2 only
2)
Available with Approvals option K only
¢
¢
J
K
Siemens FI 01 · 2015
A5E32268616
Tag, stainless steel, 12 x 45 mm (0.47 x 1.77 inch),
one text line, suitable for enclosures
7ML1930-1AC
Universal Box Bracket Mounting Kit
7ML1830-1BK
3" ASME, DN 65 PN 10, JIS 10K 3B ETFE Flange
adapter for 2" NPT
7ML1830-1BT
E
F
G
3" ASME, DN 65 PN 10, JIS 10K 3B ETFE Flange
adapter for 2" BSPT
7ML1830-1BU
2" BSPT Locknut, plastic
7ML1830-1DQ
J
2" NPT Locknut
7ML1830-1DT
4" sanitary mounting clamp
7ML1830-1BR
Spare Parts
1
2
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
4/130
Article No.
Quick Start manual, multi-language
Accessories
CE, RCM, CSA Class I, II, Div. 21)
CE, RCM, CSAus/c, FM
mounting2)
Operating Instructions
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
Approvals
4
Order code
Polycarbonate Lid
7ML1830-1LG
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
© Siemens AG 2014
Level Measurement
Point level measurement – Ultrasonic non-contacting switch
Pointek ULS200
■ Dimensional drawings
■ Schematics
Relay output
Threaded
1
60
(2.35)
Lid clip
#8-32x3/8"
machine screw
2
100 ... 230 V AC
50/60 Hz
74 (2.9)
57
(2.25)
L
N
1
2
+
-
3
4
5
6
7
8
9
Two Form ‘C’ (SPDT) relays can switch
external devices such as alarms, relays,
contactors, PLCs, DCSs, etc.
or
18 ... 30 V DC
Lid
4
Transistor output: DC version only
Conduit
connection
½" NPT or
PG 13.5
1
2
180 (7.1)
18 ... 30 V DC
+
2" NPT
R 2" BSPT
or PF2
Transducer
22 (0.87)
74 (2.9)
1
2
3
4
5
6
7
8
9
Two non-polarized transistor outputs are
suitable for connection to PLCs, DCSs,
or customer supplied relays.
Sanitary
Pointek ULS200 connections
180 (7.1)
74 (2.9)
Pointek ULS200, dimensions in mm (inch)
Siemens FI 01 · 2015
4/131
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic
Ultrasonic
■ Overview
4
■ Mode of operation
Introduction
Common Terms
Ultrasonic measurement is based on the speed of sound. Sound
can be used as a measurement tool because there is a measurable time lapse between sound generation and the "hearing" of
the sound. This time lapse is then converted into usable information. Ultrasonic sensing equipment generates a sound above
20 000 Hz and then interprets the time lapse of the returned
echo. The transducer creates the sound and senses the echo
and then a transceiver interprets the sound and converts it into
information.
Attenuation
Siemens ultrasonic units include Sonic Intelligence, a patented
signal processing technology. Using unique algorithms, Sonic
Intelligence differentiates between true echoes from the material
and false echoes from obstructions or electrical noise, providing
intelligent processing of echo profiles.
Typical System
Ultrasonic level measurement requires two components: one to
generate the sound and catch the echo (transducer) and one to
interpret the data and derive a measurement (transceiver). Even
though some ultrasonic instruments combine the components in
one unit, the individual functionality remains distinct. The measurement output is communicated to the unit, PLCs or PCs for
process control.
Principle of Operation
A piezoelectric crystal inside the transducer converts an electrical signal into sound energy, firing a burst into the air which travels to the target and then is reflected back to the transducer.
The transducer then acts as a receiving device and converts the
sonic energy back into an electrical signal contained in the
transceiver. An electronic signal processor analyzes the return
echo and calculates the distance between the transducer and
the target. The time lapse between firing the sound burst and
receiving the return echo is directly proportional to the distance
between the transducer and the material in the vessel. This
basic principle lies at the heart of the ultrasonic measurement
technology and is illustrated in the equation:
Distance = (Velocity of Sound x Time)/2.
4/132
Siemens FI 01 · 2015
Denotes a decrease in signal magnitude in transmission from
one point to another. Attenuation may be expressed as a scalar
ratio of the input magnitude to the output magnitude or in decibels.
Beam angle
The diameter of a conical boundary centered around the axis of
transmission when the power (radiating perpendicular to the
transducer face on the axis of transmission) is reduced by half
(-3 dB).
Blanking distance
Specified zone extending downward from the transducer face in
which received echoes are ignored by the transceiver. Blanking
distance ignores echoes from ringing.
Echo confidence
The recognition of the validity of the echo as material level.
A measure of echo reliability.
Ringing
The inherent nature of the transducer to continue vibrating after
the transmit pulse has ceased; the decay of the transmit pulse.
Transducer/Transceiver
A transducer provides the initial ultrasonic pulse and receives its
echo. An ultrasonic transducer amplifies the sound wave created by the piezoelectric crystal and transmits that sound wave
to the face of the transducer while at the same time dampening
the sound wave from the other sides of the crystal.
Transceivers analyze the echo from the transducer to determine
the required measurement.
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic
Ultrasonic
■ Technical specifications
Ultrasonic Transmitter/Controller Selection Guide
Criteria
SITRANS Probe LU
SITRANS LUT400
HydroRanger 200
MultiRanger 100/200
SITRANS LU
Range
6 m (20 ft) or
12 m (40 ft)
0.3 ... 60 m (1 ... 196 ft),
transducer
and application
dependent
15 m (50 ft) transducer
and application dependent
15 m (50 ft) transducer
and application dependent
60 m (200 ft) transducer
and application dependent
Typical applications
Chemical storage
vessels, filter beds,
liquid storage
vessels
Wet wells, reservoirs,
flumes/weirs,
chemical storage,
liquid storage,
hoppers, crusher
bins, dry solids
storage
Wet wells, flumes/weirs,
bar screen control
Wet wells, flumes/weirs,
bar screen control, hoppers, chemical storage,
liquid storage, crusher
bins, dry solids storage
Chemical storage, liquid
storage, bulk solids storage (sugar, flour bins,
grains, cereals),
plastic pellets
Output
HART model:
4 ... 20 mA/HART
PROFIBUS PA
model: PROFIBUS
4 ... 20 mA/HART
3 relays
6 relays standard,
two 4 ... 20 mA outputs
(isolated)
1 relay (option on
MultiRanger 100)
4 relays (LU01, LU02)
3 relays standard
4 ... 20 mA isolated
Up to 40 relays (LU10)
6 relays (option)
Two 4 ... 20 mA outputs
(isolated)
Communications
HART or
PROFIBUS PA
HART 7.0, USB,
SIMATIC PDM
Options:
• SIMATIC PDM for
remote configuration
and diagnostics
Built-in Modbus RTU/
ASCII via RS-485
Built-in Modbus RTU or
ASCII via RS-485
Dolphin, RS-232/RS-485
(LU01, LU02))
Options:
• SIMATIC PDM
• SmartLinx
(PROFIBUS DP,
DeviceNet)
Options:
• SIMATIC PDM
• SmartLinx
(PROFIBUS DP,
DeviceNet)
Dolphin via infrared
(LU10)
AC version:
100 ... 230 V AC ± 15 %,
50/60 Hz, 36 VA/17 W
DC version:
12 ... 30 V DC, 20 W
AC version:
100 ... 230 V AC ± 15 %,
50/60 Hz, 36 VA/17 W
DC version:
12 ... 30 V DC, 20 W
LU01, LU02:
AC version:
100/115/200/
230 V AC
DC version:
18 ... 30 V DC, 25 W
LU10: 100/115/200/
230 V AC
Power specifications
HART:
4 ... 20 mA,
24 V DC nominal,
max. 550 , 30 V DC
max. PROFIBUS PA:
12, 13, 15, or 20 mA,
dependent on programming
AC version:
100 ... 230 V AC ± 15 %,
50/60 Hz, 36 VA
Fuse: 5 x 20 mm,
Slow Blow,
0.25 A, 250 V DC
version:
10 … 32 V DC, 10 W
Fuse: 5 x 20 mm,
Slow Blow, 1.6 A, 125 V
Approvals
CE, CSAUS/C, FM, RCM,
ATEX, IECEx
CE, CSAUS/C, UL Listed, CE, CSAUS/C, UL Listed, CE, CSAUS/C, UL Listed, CE, CSAUS/C, FM,
FM, RCM,
FM, RCM
FM, RCM
Lloyd’s Register
Lloyd's Register, ABS
Siemens FI 01 · 2015
4/133
4
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic
Ultrasonic
4
7ML1830-2AN
7ML5830-2AJ
7ML1830-2AK
SITRANS Probe LU HART*
SITRANS LU
SITRANS Probe LU PROFIBUS
MultiRanger 100/200
HydroRanger 200
* Note: To order the IS version of this hand programmer, order 7ML5830-2AH.
Handheld programmer selection guide
4/134
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic
Ultrasonic
■ Application
Ultrasonic Level Application Questionnaire
Customer information
Contact:
Prepared By:
Company:
Date:
Address:
Notes on the Application:
City:
Country:
Zip/Postal Code:
Fax: OGGGGGP
Phone: (
E-mail:
Tanks/Vessel information
Type:
4
)
(Suppy sketch where possible)
Sketch attached
Storage
Dimensions:
Process
Height:
m/ft
Nozzle Length:
cm/inch
Pump station
Width/Diameter:
m/ft
Nozzle Diameter:
cm/inch
Critical Information
Open channel
Tank top:
Open
Sloped
Internal equipment
and/or obstructions:
Flat
Flat
(Eg. Agitator, heating coils,
supports, other)
Conical
Conical
Parabolic
Parabolic
Tank bottom:
Continuous Level
Point Level
Measurement type:
Area safety classification:
Volume
No
Yes
Please list
Flow
(Specify code required)
Material
Slurry
Material being measured:
°C/°F
Material temperature: Norm:
Atmosphere:
Air
Other
Dust:
None
Light
Installation
Max:
Liquid
Solid
°C/°F
Homogenous:
Yes
No
Heavy
(indicate all that apply)
Power available:
Communications:
Inputs required:
Outputs required:
4 ... 20 mA
Pump Interlocks (#):
HART/4 ... 20 mA
AB Remote I/O
4 ... 20 mA
PROFIBUS DP
AB DeviceNet
Relays (#):
PROFIBUS PA
Other
Modbus RTU/ASCII
None
Products recommended:
© Siemens Milltronics Process Instruments Inc.
www.siemens.com/processautomation
Form# 2-769R4
Ultrasonic Application Questionnaire
Siemens FI 01 · 2015
4/135
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic transmitters
SITRANS Probe LU
■ Overview
■ Configuration
Parabolic mounting
4
SITRANS Probe LU is a 2-wire loop powered ultrasonic transmitter for level, volume and flow monitoring of liquids in open channels, storage vessels, and simple process vessels.
Flat mounting and beam angle
■ Benefits
Fill
• Continuous level measurement up to 12 m (40 ft) range
• Easy installation and simple start-up
• Programming using infrared Intrinsically Safe handheld
programmer, SIMATIC PDM or HART Communicator
• Communication using HART or PROFIBUS PA
• ETFE or PVDF transducers for chemical compatibility
• Patented Sonic Intelligence signal processing
• Auto False-Echo Suppression for fixed obstruction avoidance
• Level to volume or level to flow conversion
Pipe
Rungs
■ Application
The SITRANS Probe LU is ideal for level monitoring in the water
and wastewater industry, chemical storage vessels, and small
bulk hoppers.
The range of SITRANS Probe LU is 6 or 12 m (20 or 40 ft).
Using Sonic Intelligence, Auto False Echo Suppression for fixed
obstruction avoidance, and accuracy of 0.15 % of range or
6 mm (0.25 inch), the Probe LU provides unmatched reliability.
The Probe LU offers two communications options: HART or
PROFIBUS PA (Profile version 3.0, Class B).
The transducer on the Probe LU is available as ETFE or PVDF to
suit the chemical conditions of your application. As well,
for applications with varying material and process temperatures,
the Probe LU incorporates an internal temperature sensor to
compensate for temperature changes.
• Key Applications: chemical storage vessels, filter beds,
liquid storage vessels
4/136
Siemens FI 01 · 2015
Seams
10°
Beam angle
SITRANS Probe LU mounting
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic transmitters
SITRANS Probe LU
■ Technical specifications
Mode of operation
Process connection
Measuring principle
Ultrasonic level measurement
Typical application
Level measurement in storage vessels and simple process vessels
• Threaded connection
2" NPT [(Taper), ANSI/ASME B1.20.1]
R 2" [(BSPT), EN 10226] or
G 2" [(BSPP), EN ISO 228-1]
Inputs
• Flange connection
3 inch (80 mm) universal flange
Measuring range
• 6 m (20 ft) model
• 12 m (40 ft) model
• Other connection
0.25 ... 6 m (10 inch ... 20 ft)
0.25 ... 12 m (10 inch ... 40 ft)
FMS 200 mounting bracket
(see page 4/187) or customer
supplied mount
Frequency
54 kHz
Display and Controls
Interface
Outputs
Local: LCD display with bar graph
Remote: Available via HART or
PROFIBUS PA
mA/HART
• Range
4 ... 20 mA
• Accuracy
± 0.02 mA
PROFIBUS PA
Profile 3, Class B
Performance
Configuration
Using Siemens SIMATIC PDM (PC) or
HART handheld communicator or
Siemens infrared handheld programmer
Memory
Non-volatile EEPROM
Resolution
 3 mm (0.12 inch)
Power supply
Accuracy
± the greater of 0.15 % of range or
6 mm (0.24 inch)
4 ... 20 mA/HART
Nominal 24 V DC with 550  maximum; maximum 30 V DC 4 ... 20 mA
Repeatability
 3 mm (0.12 inch)
PROFIBUS PA
Blanking distance
0.25 m (10 inch)
Update time
5s
12, 13, 15, or 20 mA depending on
programming (General Purpose or
Intrinsically Safe version)
• 4 ... 20 mA/HART version
 5 s at 4 mA
• PROFIBUS version
 4 s at 15 mA current loop
Temperature compensation
Built-in to compensate over temperature range
Beam angle
10°
Rated operating conditions
Ambient conditions
per IEC 61158-2
Certificates and Approvals
General
CSAUS/C, FM, CE, RCM
Marine (only applies to
HART communication option)
• Lloyd’s Register of Shipping
• ABS Type Approval
Hazardous
• Intrinsically Safe (Europe)
ATEX II 1G Ex ia IIC T4 Ga
• Intrinsically Safe (USA/Canada)
CSA/FM, Class I, Div. 1,
Groups A, B, C, D; Class II, Div. 1,
Groups E, F, G; Class III T4
• Relative humidity/ingress protection Suitable for outdoor
• Intrinsically Safe (International)
SIR 13.0008X Ex ia IIC T4 Ga
• Installation category
I
• Intrinsically Safe (Brazil)
INMETRO Ex ia IIC T4 Ga
• Pollution degree
4
• Non-incendive (USA)
FM Class I, Div. 2, Groups A, B, C, D
T4
• Location
Indoor/outdoor
• Ambient temperature
-40 ... +80 °C (-40 ... +176 °F)
• Medium conditions
- Temperature at flange or threads
-40 ... +85 °C (-40 ... +185 °F)
- Pressure (vessel)
0.5 bar g (7.25 psi g)
Design
Handheld Programmer
Intrinsically Safe Siemens handheld
programmer
Infrared receiver
• Approvals for handheld programmer ATEX II 1GD / IECEx SIR 09.0073
Material (enclosure)
PBT (Polybutylene Terephthalate)
Ex ia IIC T4 Ga
Degree of protection
Type 4X/NEMA 4X, Type 6/
NEMA 6/IP67/IP68 enclosure
Ex iaD 20 T135 °C
Weight
2.1 kg (4.6 lb)
Cable inlet
2 x M20x1.5 cable gland or
2 x ½" NPT thread or
1 x M20 x 1.5 and 1 x ½" NPT
Material (transducer)
ETFE (Ethylene Tetrafluoroethylene)
or PVDF (Polyvinylidene Fluoride)
FM/CSA Class I, II, III, Div. 1,
Groups A,B,C,D,E,F,G T6
Ambient temperature
-20 ... 50 °C (-5 ... 122 °F)
Interface
Proprietary infrared pulse signal
Power
3 V lithium battery (non-replaceable)
Siemens FI 01 · 2015
4/137
4
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic transmitters
SITRANS Probe LU
Selection and Ordering data
Article No.
Selection and Ordering data
SITRANS Probe LU
2-wire, loop powered ultrasonic transmitter for
level, volume and flow monitoring of liquids in
open channels, storage vessels, and simple
process vessels.
7ML5221-
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
7 7 7 77
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Measuring-point number/identification
(max. 27 characters) specify in plain text
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Enclosure/Cable Inlet
Plastic (PBT), 1 x M20x1.5 and 1 x ½" NPT
(no cable glands supplied)
Plastic (PBT), 2 x M20x1.5 (includes 1 general
purpose cable gland: 7ML1930-1AM)
Plastic (PBT), 2 x ½" NPT
(no cable glands supplied)
4
¢ 0
¢ 1
¢ 2
Operating Instructions for HART/mA device
Article No.
English
A5E32337695
French
7ML1998-5HT11
German
Note: The Operating Instructions should be
ordered as a separate item on the order.
A5E34957881
A5E32168031
Range/Transducer material
6 m (20 ft), ETFE
6 m (20 ft), PVDF Copolymer
¢
¢
A
B
12 m (40 ft), ETFE
12 m (40 ft), PVDF Copolymer
¢
¢
Additional Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
C
D
Operating Instructions for PROFIBUS PA device
Process connection
2" NPT [(Taper), ANSI/ASME B1.20.1]
R 2" [(BSPT), EN 10226]
G 2" [(BSPP), EN ISO 228-1]
¢
¢
¢
Communication/Output
4 ... 20 mA, HART
PROFIBUS PA
¢
¢
Approvals
General Purpose, FM, CSAUS/C, CE, RCM, KCC
¢
Non-incendive, FM Class I, Div. 2 Groups A,B,C,D ¢
1)
T5
Intrinsically Safe, CSA/FM Class I, Div. 1, Groups A, ¢
B, C, D; Class II, Div. 1, Groups E, F, G; Class III T42)
Intrinsically Safe ATEX 1G / IECEx / INMETRO
¢
Ex ia IIC T4 Ga, RCM, KCC2)
Intrinsically Safe ATEX 1G / IECEx / INMETRO
¢
Ex ia IIC T4 Ga, RCM, KCC3)
Intrinsically safe, CSA/FM Class I, Div. 1, Groups A, ¢
B, C, D; Class II, Div. 1 Groups E, F, G; Class III T43)
1)
A
B
C
1
2
Available with communication option 2 only.
3)
Available with communication option 1 only.
English
A5E32337708
German
Note: The Operating Instructions should be
ordered as a separate item on the order.
A5E34957884
Additional Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
A5E32081626
1
4
Accessories
Handheld programmer, Intrinsically Safe, EEx ia
7ML5830-2AH
5
Handheld programmer, General Purpose approvals
7ML1830-2AN
6
Handheld programmer, Infrared, Intrinsically Safe,
PROFIBUS PA
7ML5830-2AJ
7
HART modem/USB
(for use with a PC and SIMATIC PDM)
7MF4997-1DB
8
2" NPT locknut, plastic
7ML1830-1DT
2" BSPT locknut, plastic
7ML1830-1DQ
3" ASME, DN 65 PN 10, JIS 10K 3B ETFE Flange
adapter for 2" NPT
7ML1830-1BT
3" ASME, DN 65 PN 10, JIS 10K 3B ETFE Flange
adapter for 2" BSPT
7ML1830-1BU
One General Purpose polymeric cable gland
M20x1.5, rated for -20 ... +80 °C (-4 ... +176 °F)
7ML1930-1AM
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F) for
General Purpose or ATEX EEx e installations
(available for HART only)
7ML1930-1AP
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F) with integrated
shield connection (available for PROFIBUS PA)
7ML1930-1AQ
Probe LU, rock guard/sunshield kit,
304 stainless steel
7ML1930-1GH
SITRANS RD100, loop powered display see Chapter 7
7ML5741-...
SITRANS RD200, universal input display with
Modbus conversion - see Chapter 7
7ML5740-...
SITRANS RD300, dual line display with totalizer
and linearization curve and Modbus conversion see Chapter 7
7ML5744-...
SITRANS RD500 web, universal remote monitoring
solution for instrumentation - see Chapter 7
7ML5750-...
Available with Enclosure/Cable Inlet option 2 only.
2)
Order code
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
For applicable back up point level switch see point
level measurement section.
Spare Parts
Plastic lid
4/138
Siemens FI 01 · 2015
7ML1830-1KB
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic transmitters
SITRANS Probe LU
■ Options
Flange adapter for mating 2" NPT or 2" BSP process connections to
3" ASME, DN 65 PN 10 and JIS 10K 3B flanges
SITRANS Probe LU with FMS 200 mounting bracket
148.8 (5.86)
Bolt hole circle
diameter
190.2 (7.49)
Diameter
SITRANS Probe LU optional flange adapter, dimensions in mm (inch)
SITRANS Probe LU with optional mounting bracket
4
139.7 (5.50)
■ Dimensional drawings
Hinged lid
21
(0.83)
198.9 (7.83)
130.1 (5.12)
Electronics
Mounting thread
Transducer
51.1
(2.01)
54 (2.13)
Note: Above model is shown without M20 cable glands or 1/2" NPT conduit connectors.
SITRANS Probe LU, dimensions in mm (inch)
Siemens FI 01 · 2015
4/139
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic transmitters
SITRANS Probe LU
■ Schematics
Connect the wires to the
terminals as shown:
the polarity is identified
on the terminal block.
Lid screws
Terminals for loop current
or PROFIBUS PA cable
Cable
4
Watertight
gland
Note:
-
HART model above is shown with M20 cable glands. 1/2" NPT threaded connection is also available.
DC terminal shall be supplied from an SELV source in accordance with IEC-1010-1 Annex H.
All field wiring must have insulation suitable for rated input voltages.
Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes.
SITRANS Probe LU connections
4/140
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic transmitters
The Probe
■ Overview
■ Configuration
Parabolic mounting
4
The Probe is a short-range integrated ultrasonic level transmitter,
ideal for liquids and slurries in open or closed vessels.
■ Benefits
•
•
•
•
•
Easy to install, program and maintain
Accurate and reliable
Sanitary models available
Patented Sonic Intelligence echo processing
Integral temperature compensation
Flat mounting and beam angle
Fill
■ Application
The transducer is available in PVDF copolymer, making the
device suitable for use in a wide variety of applications.
The Probe is easy to install and maintain, and can be quickly
removed for cleaning as required by the food, beverage and
pharmaceutical industries.
The reliability of the level data is based on the Sonic Intelligence
echo processing algorithms. A filter discriminates between the
true echo and false echoes from acoustic or electrical noises
and agitator blades in motion. The ultrasonic pulse propagation
time to the material and back is temperature-compensated and
converted into distance for display, analog output and relay
actuation.
• Key Applications: chemical storage vessels, filter beds,
mud pits, liquid storage vessels, food applications
Pipe
Rungs
Seams
12°
Beam angle
The Probe mounting
Siemens FI 01 · 2015
4/141
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic transmitters
The Probe
■ Technical specifications
Three-wire version
Two-wire version
(standard)
Mode of operation
Measuring principle
Article No.
The Probe
Short-range integrated ultrasonic level transmitter,
ideal for liquids and slurries in open or closed
vessels
7ML1201-
Ultrasonic level
measurement
Ultrasonic level
measurement
0.25 ... 5 m
(0.8 ... 16.4 ft)
0.25 ... 5 m
(0.8 ... 16.4 ft)
Frequency
54 kHz
54 kHz
Output
• mA
4 ... 20 mA
4 ... 20 mA
- Span
Proportional/
inversely proportional
Proportional/
inversely proportional
- Max. load
750  at 24 V DC
For level alarm or fault
600  in the loop at
24 V DC
No
Supply voltage
18 ... 30 V DC,
max. 0.2 A
12 ... 30 V DC,
0.1 A surge
Max. power consumption
5W
(200 mA at 24 V DC)
0.75 W
(25 mA at 24 V DC)
Further designs
Certificates and
approvals
CE, RCM, CSAUS/C, FM
CE, RCM, CSAUS/C
Please add "-Z" to Article No. and specify Order
code(s).
Input
Measuring range
4
Selection and Ordering data
• Relay
Power supply
Accuracy
• Error in measurement
• Resolution
• Temperature compensation
• Echo processing
Rated operation conditions
• Beam angle
• Ambient temperature
- Standard
- Metallic mounting
• Max. static operating
pressure
• Degree of protection
Design
• Weight
- Without flange
adapter
- With flange adapter
• Material
- Electronics enclosure
- Transducer
• Degree of protection
• Process connection
• Flange adapter
• Cable inlet
0.25 % of measuring range (in air)
3 mm (0.125 inch)
Built in
Sonic Intelligence
12°
-40 ... +60 °C (-40 ... +140 °F)
-20 ... +60 °C (-4 ... +140 °F)
Normal atmospheric pressure
IP65
1.5 kg (3.3 lb)
1.7 kg (3.7 lb)
PVC
PVDF copolymer
IP65
2" NPT [(Taper), ANSI/ASME B1.20.1]
R 2" [(BSPT), EN 10226] or
G 2" [(BSPP), EN ISO 228-1]
3" Universal,
(fits DN 65, PN 10 and 3"ASME)
4" sanitary
2 inlets for PG 16 or ½" NPT cable glands
777 0 0
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Measuring range
5 m (16.40 ft)
¢ 1
Transducer/Process connection
PVDF copolymer, 2" NPT [(Taper),
ANSI/ASME B1.20.1]
PVDF copolymer, R 2" [(BSPT), EN 10226]
PVDF copolymer, G 2" [(BSPP), EN ISO 228-1]
PVDF copolymer, 4" Sanitary mounting
Model/Approval
3 Wire, 24 V DC, CE, RCM, CSA, FM
2 Wire, 24 V DC, CE, RCM, CSA
¢
E
¢
¢
¢
F
G
J
¢
¢
E
F
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Selection and Ordering data
Acrylic coated, stainless steel tag [13 x 45 mm
(0.5 x 1.75 inch)]: Measuring-point number/
identification (max. 20 characters) specify in
plain text
Order code
¢ Y17
Additional Operating Instructions
Article No.
3 Wire, 24 V model, Multi-language manual
7ML1998-5GD62
2 Wire model, Multi-language manual
A5E32243983
Accessories
Universal Box Bracket Mounting kit
7ML1830-1BK
Sanitary 4" mounting clamp
7ML1830-1BR
3" ASME, DN 65 PN 10, JIS 10K 3B ETFE Flange
adapter for 2" NPT
7ML1830-1BT
3" ASME, DN 65 PN 10, JIS 10K 3B ETFE Flange
adapter for 2" BSPT
7ML1830-1BU
2" NPT locknut, plastic
7ML1830-1DT
2" BSPT locknut, plastic
7ML1830-1DQ
Plastic M20 cable gland with metal locknut
7ML1930-1DB
SITRANS RD100, loop powered display see Chapter 7
7ML5741-...
SITRANS RD200, universal input display with
Modbus conversion - see Chapter 7
7ML5740-...
SITRANS RD300, dual line display with totalizer
and linearization curve and Modbus conversion see Chapter 7
7ML5744-...
SITRANS RD500 web, universal remote monitoring
solution for instrumentation - see Chapter 7
7ML5750-...
For applicable back up point level switch see point
level measurement section.
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
4/142
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic transmitters
The Probe
■ Options
■ Dimensional drawings
Standard model
Hinged lid
7 (0.3)
Flange adapter for mating 2" NPT or 2" BSP process connections to
3" ANSI, DN 65 PN10, and JIS 10K 3B flanges
148.8 (5.86)
bolt hole circle
diameter
84 (3.3) max.
190.2 (7.49)
diameter
Cable entry
‘knock out’
The Probe Optional Flange Adapter, dimensions in mm (inch)
279 (11)
117 (4.6)
Electronics
87
(3.4) Ø
The Probe with FMS 200 mounting bracket
74
(2.9)
Mounting
thread
61 (2.4)
Mounting
thread
transducer
53 (2.1) max.
Hinged
lid
The Probe with Optional Mounting Bracket
■ Schematics
7 (0.3)
Sanitary model
84 (3.3) max.
3 wire model
(standard and sanitary models)
Cable entry
‘knock out’
mA output: 4 ... 20 mA, nonisolated, 750 Ω max.
87
(3.4) Ø
279 (11)
117 (4.6)
Electronics
Process
connection
74
(2.9)
Power supply
Connect to protective earth
Transducer
Relays: dry contact, closed
unpowered or alarm state
61 (2.4)
2 wire model
(standard and sanitary models)
Probe
+
–
Loop
instrumentation
R max
+ –
53 (2.1) max.
The Probe, dimensions in mm (inch)
1 2
R max =
V supply
V supply – 12 V
+
20 mA
12 ... 30 V DC –
Display
Program
mode
Segment
display
'20' key
Units
'4' key
Operation
status
LOE/fault
The Probe connections
Siemens FI 01 · 2015
4/143
4
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic controllers
SITRANS LUT400 series
■ Overview
■ Application
The SITRANS LUT400 comes in three different models, depending on the application, level of performance and functionality
required:
• SITRANS LUT420 Level Controller: Level or volume
measurement of liquids, slurries, and solids, as well as basic
pump control functions, and basic data logging capability
• SITRANS LUT430 Level, Pump and Flow Controller: Includes
all features of the LUT420 plus a full suite of advanced pump
control and alarm functionality, open channel flow monitoring,
and basic flow data logging capability
• SITRANS LUT440 High Accuracy OCM: Our most featured,
highest accuracy model. Includes all features of the LUT430,
plus the industry’s best accuracy (± 1 mm within 3 m), full suite
of advanced control functionality, and enhanced flow logging
capability
• Key applications: wet wells, reservoirs, flumes/weirs, chemical
storage, liquid storage, hoppers, crusher bins, dry solids
storage
4
The Siemens SITRANS LUT400 series controllers are compact,
single point, long-range ultrasonic controllers for continuous
level or volume measurement of liquids, slurries, and solids,
and high accuracy monitoring of open channel flow.
■ Benefits
• Small 1/2 DIN enclosure [144 h x 144 d x 146 w mm
(5.7 x 5.7 x 5.75 inch)] with standard universal mounting
bracket for wall, pipe, and DIN rail, plus an optional panel
mount
• Easy to use HMI display with local four-button programming,
menu-driven parameters, and Wizard support for key applications
• English, German, French, Spanish, Chinese, Italian, Portuguese, and Russian texts on the HMI.
• Level, Volume, OCM Flow monitoring
• Three relays combined with a suite of pump, alarm, and relay
control features
• HART Communications
• EDDs for SIMATIC PDM, AMS Device Manager, and Field
Communicator 375/475, plus DTMs for FDTs (Field Device
Tools)
• Web browser for local programming from an intuitive webbased interface
• Two discrete inputs for backup level override and pump
interlock functions
• Echo profile and trend views from the local display
• Patented digital receiver for improved performance in electrically noisy applications (close proximity to VSDs)
• Real time clock with daylight savings time, supporting an
integrated datalogger and energy saving algorithms for
minimizing pump operation during high cost energy periods
• Removable terminal blocks for ease of wiring
• MCERTS Certified for Open Channel Flow
4/144
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic controllers
SITRANS LUT400 series
■ Technical specifications
Mode of Operation
Ultrasonic level, volume, pump,
and open channel flow
Measuring range
0.3 … 60 m (1 … 196 ft),
transducer dependent
Input
Discrete
0 ... 50 V DC switching level
Logical 0  10 V DC
Logical 1 = 10 ... 50 V DC
Max. 3 mA
Output
10 ... 52 kHz
Ultrasonic transducer
Compatible transducers: All EchoMax and ST-H series transducers
Relays
• 1 SPDT Form C, NO or NC relay,
rated 1A at 250 V AC,
non-inductive and 3A at 30 V DC
• 2 SPST Form A, NO relays,
rated 5A at 250 V AC,
non-inductive and 3 A at 30 V DC
• Resolution
Weight
• Enclosure with display lid
• Enclosure with blank lid:
1.3 kg (2.87 lb)
1.2 kg (2.65 lb)
Material (enclosure)
Polycarbonate
Degree of protection
• Enclosure with display or blank lid: IP65/Type 4X/NEMA 4X
• Enclosure with blank lid and knock- IP20
out removed:
Remote display lid:
Transducer frequency
mA output
• Max. load
Design
4 … 20 mA, isolated
600  max. in ACTIVE mode,
750  max. in PASSIVE mode
0.1 % of range
Transducer and mA output signal
• Standard operation: ± 1 mm
(0.04 inch) plus 0.17 % of measured
distance
• High accuracy OCM: ± 1 mm
(0.04 inch), within 3 m (9.84 ft)
range
Resolution
• Standard operation: 0.1 % of range
or 2 mm (0.08 inch), whichever is
greater
• High accuracy OCM: 0.6 mm
(0.02 inch), within 3 m (9.84 ft)
range
Temperature compensation
• -40 ... +150 °C (-40 ... +300 °F)
• Integral temperature sensor in transducer
• External TS-3 temperature sensor
(optional)
• Programmable fixed temperature
values
Rated operating conditions
Installation conditions
• Location
• Installation category
• Pollution degree
Indoor/outdoor
II
4
Ambient conditions
• Ambient temperature (enclosure)
-20 … +50 °C (-4 … +122 °F)
• Transducer, mA output:
2 copper conductors, twisted,
with foil shield/drain wire, 300 V
0.5 … 0.75 mm² (22 … 18 AWG)
• Relay/power to be copper
conductors per local
requirements to meet 250 V
5 A contact rating
Max. separation between
transducer and transceiver
365 m (1 200 ft)
Displays and controls
60 x 40 mm (2.36 x 1.57 inch)
removable
LCD, 240 x 160 pixels resolution,
operational up to 5 m from
enclosure base
Accuracy
Error in measurement
IP65/Type 3/NEMA 3
Cable
Programming
• Primary
• Secondary
Memory
4 Local push buttons
• PC running SIMATIC PDM
• PC running Emerson AMS Device
Manager
• PC running a web browser
• PC running a Field Device Tool
(FDT)
• Field Communicator 375/475
(FC375/FC475)
• 512 kB flash EPROM
• 1.5 MByte flash for data logging
Power supply
AC version
100 ... 230 V AC ± 15 %,
50/60 Hz, 36 VA
Fuse: 5 x 20 mm, Slow Blow,
0.25 A, 250 V
DC version
10 … 32 V DC, 10 W
Fuse: 5 x 20 mm, Slow Blow,
1.6 A, 125 V
Certificates and approvals
General
Hazardous
• Non-incendive
(Canada)
CSAUS/C, CE, FM, UL listed, RCM,
MCERTS certified for
Open Channel Flow
• Shipping
CSA Class I, Div. 2,
Groups A, B, C, D;
Class II, Div. 2, Groups F, G;
Class III
Lloyd's Register, ABS
Communication
HART 7.0, USB
Siemens FI 01 · 2015
4/145
4
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic controllers
SITRANS LUT400 series
SITRANS LUT420
SITRANS LUT430
SITRANS LUT440
Category
Feature
Level Controller
Level, pump and flow
controller
High accuracy OCM
controller
Operations
Level, space, and distance
measurement





Open channel flow measurement



Compatible with EchoMax and 
ST-H transducers


Standard accuracy: ± 1 mm

+0.17 % of measured distance


Volume conversion
Specifications

High accuracy: ± 1 mm within
3 meters
4
Data logging and communications
Mounting options: wall or
panel, pipe, DIN-rail



HART communications



4 ... 20 mA output (active and 
passive)







Integrated datalogger for
measurement value and
alarms
Integrated datalogger for fixed
rate flow logging

Integrated datalogger for
variable rate flow logging
triggered by changes in flow
condition

Daily data logging for maximum, minimum and average
flow, daily totalized volume,
and minimum and maximum
temperature
Flow monitoring

High accuracy open channel
flow measurement
9 digit daily and running flow
totalizers


High and low flowrate alarms


External totalizer and sampler
control



MCERTS Class 1 Certification
Pump control
MCERTS Class 2 Certification

Energy saving algorithms for
pump control




Pump run-on functionality


Pump start and power
resumption delays










Discrete input pump interlocks


Time to spill calculation


Wall cling reduction
Alternate duty pump routines


Fixed duty and service ratio
pump routines
Pumped volume totalizer
Submergence detection
4/146

Siemens FI 01 · 2015

© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic controllers
SITRANS LUT400 series
Selection and Ordering data
Article No.
Communications Manual
SITRANS LUT420 and LUT430
Compact ultrasonic level controllers for continuous
short to long-range level or volume measurement of
liquids, slurries, and solids. Both units include
basic relay functions for pumps, alarms, and other
controls, plus onboard data logging. LUT430 offers
additional advanced pump control and alarm
functionality, open channel flow monitoring,
and basic flow data logging capability.
Functionality varies by model.
7ML5050-
English
7ML1998-5NE01
00 7 7 7 7 0- 7 77 00
French
7ML1998-5NE11
Spanish
7ML1998-5NE21
German
7ML1998-5NE31
Italian
Note: The communications manual should be
ordered as a separate line item on the order.
7ML1998-5NE51
Accessories
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Model
SITRANS LUT420 - Level controller
¢
SITRANS LUT430 - Level, Pump & Flow controller ¢
Enclosure display options
With display
¢
With remote panel mount display
¢
[Includes panel mount cable extension, 2.5 m
(8.2 ft)]
No display (blank lid provided)
¢
Note: Enclosure includes back-plate for wall
and pipe mounting, and an integrated clip for
DIN-rail mounting. DIN-rail mounting for standard
TS35 x 7.5 and TS35 x 15 mm DIN-rail to
IEC 60715, EN 60715
Input voltage
100 ... 230 V AC ± 15 %
10 ... 32 V DC
A
B
A
B
C
¢
¢
1
2
Cable inlet
3 cable inlets, cable glands not supplied
¢
3 cable inlets, 3 M20 plastic cable glands supplied¢
1
2
Approvals
General purpose CE, FM, CSAUS/C, UL, RCM
Hazardous locations CSA Class I, II, III, Div. 2
(Groups A, B, C, D, F, G)
7ML1930-1AC
TS-3 Temperature Sensor - see TS-3 on page 4/189
7ML1813-...
Panel mount cable extension, 2.5 m (8.2 ft)
7ML1930-1GF
Qty 3 cable glands and retaining nuts
7ML1930-1GB
USB cable, 2 m (6.56 ft) - Standard USB-A to
USB-mini B
7ML1930-1GD
Hart modem/USB
(for use with a PC and SIMATIC PDM)
7MF4997-1DB
Sunshield, 304 stainless steel
7ML1930-1GE
SITRANS RD100, loop powered display see Chapter 7
7ML5741-...
SITRANS RD200, universal input display with
Modbus conversion - see Chapter 7
7ML5740-...
SITRANS RD300, dual line display with totalizer and
linearization curve and Modbus conversion - see
Chapter 7
7ML5744-...
SITRANS RD500 web, universal remote monitoring
solution for instrumentation - see Chapter 7
7ML5750-...
Spare parts
Number of measurement points
Single point system (includes one transducer input, ¢
one mA output, and one external temperature
sensor input)
Communications and I/O
HART, 2 discrete inputs, 3 relays
Tag, stainless steel, 12 x 45 mm (0.47 x 1.77 inch),
one text line, suitable for enclosure
1
¢
D
¢
A
C
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Panel mount retrofit kit (convert standard unit with
display to panel mount version)
7ML1830-1PA
Terminal block replacement kit
(5 piece kit with one of each removable terminal)
7ML1830-1PB
Wall/Pipe mount plate
7ML1830-1PC
Enclosure (include blank label)
7ML1830-1PD
SITRANS LUT400 Lid (with Display)
7ML1830-1PE
SITRANS LUT400 Lid (blank)
7ML1830-1PF
Fuse - AC (0.25 A, 250 V, Slow Blow)
7ML1830-1PG
Fuse - DC (1.6 A, 125 V, Slow Blow)
7ML1830-1PH
Battery BR2032
7ML1830-1PJ
Panel mount gasket and fastener kit
7ML1830-1PK
Further designs
DIN-rail clip
7ML1830-1PL
Please add "-Z" to Article No. and specify Order
code(s).
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Selection and Ordering data
Manufacturer's test certificate M to DIN 55350,
Part 18 and to ISO 9000
Order code
¢ C11
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Measuring-point number/identification
(max. 27 characters) specify in plain text
Namur NE43 failsafe setting - device preset to
failsafe < 3.6 mA
¢ N07
Operating Instructions
Article No.
English
7ML1998-5MV01
French
7ML1998-5MV11
Spanish
7ML1998-5MV21
German
7ML1998-5MV31
Italian
7ML1998-5MV51
Multi-language compact operating instructions
Note: The operating instructions should be
ordered as a separate line item on the order.
7ML1998-5XU81
Siemens FI 01 · 2015
4/147
4
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic controllers
SITRANS LUT400 series
Selection and Ordering data
Article No.
Communications Manual
SITRANS LUT440
The SITRANS LUT440 is the most accurate and
featured model in the LUT400 series. It includes
high accuracy open channel monitoring, relay
functions for external samplers, totalizers, alarms,
and enhanced data logging, as well as all pump
and control functions available with other models in
the LUT400 series.
7ML5050-
English
7ML1998-5NE01
00 7 7 7 7 0- 7 77 00
French
7ML1998-5NE11
Spanish
7ML1998-5NE21
German
7ML1998-5NE31
Italian
7ML1998-5NE51
Note: The communications manual should be
ordered as a separate line item on the order.
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Model
SITRANS LUT440 - High accuracy Open Channel ¢
Monitor1)
4
Enclosure display options
With display
¢
With remote panel mount display
¢
[Includes panel mount cable extension, 2.5 m
(8.2 ft)]
No display (blank lid provided)
¢
Note: Enclosure includes back-plate for wall
and pipe mounting, and an integrated clip for
DIN-rail mounting. DIN-rail mounting for standard
TS35 x 7.5 and TS35 x 15 mm DIN-rail to
IEC 60715, EN 60715
Input voltage
100 ... 230 V AC ± 15 %
10 ... 32 V DC
Accessories
C
A
B
C
¢
¢
1
2
Cable inlet
3 cable inlets, cable glands not supplied
¢
3 cable inlets, 3 M20 plastic cable glands supplied¢
1
2
Number of measurement points
Single point system (includes one transducer input, ¢
one mA output, and one external temperature
sensor input)
Communications and I/O
HART, 2 discrete inputs, 3 relays
Approvals
General purpose CE, FM, CSAUS/C, UL, RCM
Hazardous locations CSA Class I, II, III, Div. 2,
(Groups A, B, C, D, F, G)
1)
1
¢
D
¢
A
C
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Order code
Further designs
¢ C11
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Measuring-point number/identification
(max. 27 characters) specify in plain text
Namur NE43 failsafe setting - device preset to
failsafe < 3.6 mA
¢ N07
Operating Instructions
Article No.
English
7ML1998-5MV01
French
7ML1998-5MV11
Spanish
7ML1998-5MV21
German
7ML1998-5MV31
Italian
7ML1998-5MV51
Note: The operating instructions should be
ordered as a separate line item on the order.
4/148
Siemens FI 01 · 2015
TS-3 Temperature Sensor - see TS-3 on page 4/189
7ML1813-...
Panel mount cable extension 2.5 m (8.2 ft)
7ML1930-1GF
Qty 3 cable glands and retaining nuts
7ML1930-1GB
USB cable 2 m (6.56 ft) - Standard USB-A to
USB-mini B
7ML1930-1GD
HART modem/USB
(for use with PC and SIMATIC PDM)
7MF4997-1DB
Sunshield, 304 stainless steel
7ML1930-1GE
SITRANS RD100, loop powered display see Chapter 7
7ML5741-...
SITRANS RD200, universal input display with
Modbus conversion - see Chapter 7
7ML5740-...
SITRANS RD300, dual line display with totalizer and
linearization curve and Modbus conversion - see
Chapter 7
7ML5744-...
SITRANS RD500 web, universal remote monitoring
solution for instrumentation - see Chapter 7
7ML5750-...
Panel mount retrofit kit (convert standard unit with
display to panel mount version)
7ML1830-1PA
Terminal block replacement kit
(5 piece kit with one of each removable terminal)
7ML1830-1PB
Wall/Pipe mount plate
7ML1830-1PC
Enclosure (include blank label)
7ML1830-1PD
SITRANS LUT400 Lid (with Display)
7ML1830-1PE
SITRANS LUT400 Lid (blank)
7ML1830-1PF
Fuse - AC (0.25 A, 250 V, Slow Blow)
7ML1830-1PG
Fuse - DC (1.6 A, 125 V, Slow Blow)
7ML1830-1PH
Battery BR2032
7ML1830-1PJ
Panel mount gasket and fastener kit
7ML1830-1PK
DIN-rail clip
7ML1830-1PL
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix
Please add "-Z" to Article No. and specify Order
code(s).
Manufacturer's test certificate M to DIN 55350,
Part 18 and to ISO 9000
7ML1930-1AC
Spare parts
Compatible with all EchoMax Transducers. High accuracy OCM
performance with the use of an XRS-5 transducer and TS-3 temperature
sensor (each sold separately).
Selection and Ordering data
Tag, stainless steel, 12 x 45 mm (0.47 x 1.77 inch),
one text line, suitable for enclosure
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic controllers
SITRANS LUT400 series
■ Dimensional drawings
Back
mount
bracket
Enclosure
SITRANS LUT400
198
(7.8)
190
(7.5)
144
(5.7)
22
(0.87)
34
(1.34)
98°
33
(1.34)
Cable entry
(3 places)
259
(10.2)
155
(6.10)
146
(5.75)
45
(1.2)
SITRANS LUT400, dimensions in mm (inch)
Siemens FI 01 · 2015
4/149
4
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic controllers
SITRANS LUT400 series
1.80 ± 1.00
(0.07 ± 0.04)
110.00 ± 1.00
(4.33 ± 0.04)
5.50 (0.22) dia.
(4 places)
13.50 ± 1.00
(0.53 ± 0.04)
4
97.00 ± 1.00
(3.81 ± 0.04)
125.00
(4.92)
6.25 (0.25) rad.
(4 places)
Cut-out
Note: Cut-out template
(printed to scale) shipped
with remote panel mount
model.
125.00
(4.92)
SITRANS LUT400, dimensions in mm (inch)
4/150
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic controllers
SITRANS LUT400 series
■ Schematics
INPUT
POWER
12
13
14
1.6 A,125 V
SLOW BLOW 10 - 32 V
TS-3 TRANSDUCER
4
5
6
7
8
1
10
9
2
1
DC SYNC
WHT
3
BLK
WHT
2
SHLD
BLK
1
INPUT
POWER
DISCRETE INPUTS
RELAYS
0.25 A, 250 V
SLOW BLOW
12
L1
13
L2/N
4
14
XWWGTGYZWG}
BATTERY
BR2032
mA OUT/HART
DISPLAY
15
16
RLY 1
17
18
19
RLY 2
20
21
22
23
RLY 3
24
PAS
ACT
SERVICE
SITRANS LUT400 connections
Siemens FI 01 · 2015
4/151
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic controllers
MultiRanger 100/200
■ Overview
■ Application
MultiRanger can be used on different materials, including fuel
oil, municipal waste, acids, woodchips, or on materials with high
angles of repose. MultiRanger offers true dual point monitoring,
digital communications with built-in Modbus RTU via RS-485,
as well as compatibility with SIMATIC PDM, allowing PC configuration and setup. MultiRanger features Sonic Intelligence
advanced echo-processing software for increased reading reliability.
MultiRanger 100 offers cost-effective level alarming, as well as
on/off and alternating pump control. MultiRanger 200 will monitor
open channel flow and features more advanced relay alarming
and pump control functions as well as volume conversion.
It is compatible with chemical-resistant EchoMax transducers
that can be used in hostile environments at temperatures as high
as 145 °C (293 °F).
• Key Applications: wet wells, flumes/weirs, bar screen control,
hoppers, chemical storage, liquid storage, crusher bins,
dry solids storage
4
MultiRanger is a versatile short to medium-range ultrasonic
single and multi-vessel level monitor/controller for virtually any
application in a wide range of industries.
The MultiRanger is available in wall or panel mounting options.
■ Benefits
• Digital input for back-up level override from point level device
• Communication using built-in Modbus RTU via RS-485
• Compatible with SmartLinx system and SIMATIC PDM
configuration software
• Single or dual point level monitoring
• Auto False-Echo Suppression for fixed obstruction avoidance
• Differential amplifier transceiver for common mode noise
reduction and improved signal-to-noise ratio
• MultiRanger 100: level measurements, simple pump control,
and level alarm functions
• MultiRanger 200: level, volume and flow measurements in
open channels, differential control, extended pump control,
and alarm functions
• Wall and panel mounting options
4/152
■ Design
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic controllers
MultiRanger 100/200
■ Technical specifications
Mode of Operation
Measuring principle
Ultrasonic level measurement
Measuring range
0.3 ... 15 m (1 ... 50 ft)
Measuring points
1 or 2
Input
• Analog (MultiRanger 200 only)
• Discrete
Output
EchoMax transducer
Ultrasonic transducer
Relays
• Version with 1 relay
(MultiRanger 100 only)
• Version with 3 relays
• Version with 6 relays
mA output
• Max. load
• Resolution
Accuracy
Error in measurement
Resolution
Temperature compensation
0 ... 20 mA or 4 ... 20 mA, from alternate device, scalable
10 ... 50 V DC switching level
Logical 0  0.5 V DC
Logical 1 = 10 ... 50 V DC
Max. 3 mA
Design
Weight
• Wall mount
• Panel mount
Material (enclosure)
Degree of protection (enclosure)
• Wall mount
• Panel mount
Electrical connection
• Transducer and mA output signal
44 kHz
Compatible transducers: ST-H and
EchoMax series XPS-10, XPS 15/15F,
and XRS-5
Rating 5 A at 250 V AC, non-inductive
1 SPST Form A
• Max. separation between
transducer and transceiver
2 SPST Form A/1 SPDT Form C
4 SPST Form A/2 SPDT Form C
0 ... 20 mA or 4 ... 20 mA
750 , isolated
0.1 % of range
Power supply
• AC version
0.25 % of range or 6 mm (0.24 inch),
whichever is greater
0.1 % of measuring range1)
or 2 mm (0.08 inch), whichever is
greater
• -50 ... +150 °C (-58 ... +302 °F)
• Integral temperature sensor
• External TS-3 temperature sensor
(optional)
• Programmable fixed temperature
values
Displays and controls
Programming
• DC version
Indoor/outdoor
II
4
Ambient conditions
• Ambient temperature (housing)
-20 ... +50 °C (-4 ... +122 °F)
IP65/Type 4X/NEMA 4X
IP54/Type 3/NEMA 3
2-core copper conductor, twisted,
shielded, 0.5 ... 0.75 mm²
(22 ... 18 AWG), Belden 8760 or
equivalent is acceptable
365 m (1 200 ft)
100 x 40 mm (4 x 1.5 inch) multiblock LCD with backlighting
Programming using hand-held
programmer, SIMATIC PDM or via PC
with Dolphin Plus software
100 ... 230 V AC ± 15 %,
50/60 Hz, 36 VA (17 W)
12 ... 30 V DC (20 W)
CE, RCM2)
Lloyd’s Register of Shipping
ABS Type Approval
FM, CSAUS/C, UL listed
CSA Class I, Div. 2, Groups A, B, C
and D, Class II, Div.2, Groups F and
G, Class III (wall mount only),
ATEX II 3D
Certificates and approvals
•
•
•
•
•
Communication
• RS 232 with Modbus RTU or
ASCII via RJ-11 connector
• RS 485 with Modbus RTU or
ASCII via terminal strips
• Optional: SmartLinx cards for
- PROFIBUS DP
- DeviceNet
Rated operating conditions
Installation conditions
• Location
• Installation category
• Pollution degree
1.37 kg (3.02 lb)
1.50 kg (3.31 lb)
Polycarbonate
1)
Program range is defined as the empty distance to the face of the transducer plus any range extension
2)
EMC performance available on request
Siemens FI 01 · 2015
4/153
4
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic controllers
MultiRanger 100/200
Selection and Ordering data
Article No.
Selection and Ordering data
MultiRanger 100/200
Versatile short to medium-range ultrasonic single
and multi-vessel level monitor/controller for virtually
any application in a wide range of industries
7ML5033-
Further designs
7 7 7 77 - 77
Please add "-Z" to Article No. and specify Order
code(s).
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Measuring-point number/identification
(max. 27 characters) specify in plain text
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Versions
MultiRanger 100, level measurement only
¢ 1
MultiRanger 200, level, volume, flow and differential ¢ 2
measurements
Mounting, enclosure design
Wall mount, standard enclosure
¢
Wall mount, 4 entries, 4 M20 cable glands included¢
Panel mount (CE, CSAUS/C, FM, UL)
¢
4
Power supply
100 ... 230 V AC
12 ... 30 V DC
¢
¢
Number of measurement points
Single point version
Dual point version
¢
¢
Communication (SmartLinx)
Without module
SmartLinx PROFIBUS DP module
SmartLinx DeviceNet module
See SmartLinx product on page 4/360 for
more information.
Output relays
3 relays (2 Form A, 1 Form C), 250 V AC
6 relays (4 Form A, 2 Form C), 250 V AC
1 relay (1 Form A), 250 V AC
(available on MultiRanger 100 model only)
For wall mount applications only
2)
For standard enclosure wall mount, option A only
A
B
C
A
B
0
1
Operating Instructions
Article No.
English
7ML1998-5FB06
French
7ML1998-5FB13
Spanish
7ML1998-5FB23
German
7ML1998-5FB36
Quick Start guide, multi-language
Note: The Operating Instructions should be
ordered as a separate item on the order.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
7ML1998-5QD83
Other Operating Instructions
SmartLinx PROFIBUS DP, English
7ML1998-1AQ03
7ML1998-1AQ33
¢
¢
0
2
SmartLinx PROFIBUS DP, German
SmartLinx PROFIBUS DP, French
7ML1998-1AQ13
¢
3
SmartLinx DeviceNet, English
Note: The appropriate SmartLinx Operating
Instructions should be ordered as a separate line
on the order.
7ML1998-1BH02
¢
¢
¢
Approvals
General Purpose CE, FM, CSAUS/C,
¢
UL listed, RCM
CSA Class I, Div. 2, Groups A, B, C and D; Class II, ¢
Div. 2, Groups F and G; Class III1)
ATEX II 3D2)
¢
1)
Order code
1
2
3
Accessories
Handheld programmer
7ML1830-2AK
Tag, stainless steel, 12 x 45 mm (0.47 x 1.77 inch),
one text line, suitable for enclosure
7ML1930-1AC
A
M20 cable gland kit (4 M20 cable glands,
4 M20 nuts, 4 washers)
7ML1930-1FV
B
Sunshield kit, 304 stainless steel
7ML1930-1GA
C
SITRANS RD100, loop powered display see Chapter 7
7ML5741-...
SITRANS RD200, universal input display with
Modbus conversion - see Chapter 7
7ML5740-...
SITRANS RD300, dual line display with totalizer
and linearization curve and Modbus conversion see Chapter 7
7ML5744-...
SITRANS RD500 web, universal remote monitoring
solution for instrumentation - see Chapter 7
7ML5750-...
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Spare parts
Power Supply Board (100 ... 230 V AC)
7ML1830-1MD
Power Supply Board (12 ... 30 V DC)
7ML1830-1ME
Display Board
7ML1830-1MF
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
4/154
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic controllers
MultiRanger 100/200
■ Dimensional drawings
■ Schematics
Wall mount version
14.9
160.3 (6.325)
(0.58)
15.2
130 (5.125)
(0.6)
Mounting
holes
Ø 4.3
(0.17) (x4)
TB1
See note 1
91
(3.58)
6.6
(0.26)
TB1
TB2
+
240 (9.45)
227 (8.93)
Cover
screws
(x6)
L2/N L1
-
- +
2
TB3
12 ... 30 V
SYNC
1
DC version
+
mA INPUT
+
SHIELD
Relay 1
1
Suitable location for
conduit entrances
Siemens Milltronics
recommends using a hole
punch for drilling the holes.
+
+
Relay 3
TS-3
SHIELD
1
Relay 4
36
(1.40)
4
2
Panel mount version
198 (7.80)
+
-
4 ... 20 mA
OUTPUTS
Relay 2
Housing
Mounting screw
(provided by customer)
Mounting holes
(accessed under lid)
Ø 4.3 (0.17) (x4)
97
(3.82)
Relay 5
DISCRETE
INPUTS
2
COM
278 (10.94)
Relay 6
RS 485
Relays shown in released
state
A
B
Note:
1. Use 2-core copper wire, twisted, with shield, for expansion up to
365 m (1 200 ft). Route cable in grounded metal conduit, separate
from other cables.
2. Verify that all system components are installed in accordance with
instructions.
MultiRanger, dimensions in mm (inch)
3. Connect all cable shields to the MultiRanger shield connections.
Avoid differential ground potentials by not connecting cable shields
to ground (earth) anywhere else.
4. Keep exposed conductors on shielded cables as short as possible
to reduce noise on the line caused by stray transmissions and noise
pickup.
MultiRanger connections
Siemens FI 01 · 2015
4/155
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic controllers
HydroRanger 200
■ Overview
■ Application
For water authorities, municipal water, and wastewater plants,
HydroRanger 200 is an economical, low-maintenance solution
delivering control efficiency and productivity needed to meet
today’s exacting standards. It offers single point monitoring with
all models, and optional dual-point monitoring with 6 relay
model. As well, it has digital communications with built-in
Modbus RTU via RS-485.
The standard 6 relay HydroRanger 200 will monitor open channel flow and features more advanced relay alarming and pump
control functions as well as volume conversion. It is compatible
with SIMATIC PDM, allowing for PC configuration and setup.
Sonic Intelligence advanced echo-processing software provides increased reading reliability. The optional 1 or 3 relay models provide accurate level measurement functions only; these
two models do not provide open channel flow, differential level
measurement or volume conversion functions.
4
HydroRanger 200 is an ultrasonic level controller for up to
six pumps and provides control, differential control, and open
channel flow monitoring.
■ Benefits
• Monitors wet wells, weirs and flumes
• Digital communications with built-in Modbus RTU via RS-485
• Compatible with SmartLinx system and SIMATIC PDM configuration software
• Single or dual point level monitoring
• 6 relay (standard), 1 or 3 relay (optional)
• Auto False-Echo Suppression for fixed obstruction avoidance
• Anti-grease ring/tide mark buildup
• Differential amplifier transceiver for common mode noise
rejection and improved signal-to-noise ratio
• Wall and panel mounting options
4/156
Siemens FI 01 · 2015
HydroRanger 200 uses proven continuous ultrasonic echo ranging technology to monitor water and wastewater of any consistency up to 15 m (50 ft) in depth. Achievable resolution is 0.1 %
with accuracy to 0.25 % of range. Unlike contacting devices,
HydroRanger 200 is immune to problems caused by suspended
solids, harsh corrosives, grease or silt in the effluent, reducing
downtime.
• Key Applications: wet wells, flumes/weirs, bar screen control
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic controllers
HydroRanger 200
■ Technical specifications
Design
Mode of Operation
Measuring principle
Ultrasonic level measurement
Measuring range
0.3 ... 15 m (1 ... 50 ft),
transducer dependent
Weight
• Wall mount
• Panel mount
1.37 kg (3.02 lb)
1.50 kg (3.31 lb)
Measuring points
1 or 2
Material (enclosure)
Polycarbonate
Degree of protection (enclosure)
• Wall mount
• Panel mount
IP65/Type 4X/NEMA 4X
IP54/Type 3/NEMA 3
Input
Analog
0 ... 20 mA or 4 ... 20 mA,
from alternate device, scalable
(6 relay model)
Discrete
10 ... 50 V DC switching level
Logical 0  0.5 V DC
Logical 1 = 10 ... 50 V DC
Max. 3 mA
Output
EchoMax transducer
44 kHz
Ultrasonic transducer
Compatible transducers: ST-H and
EchoMax series XPS-10, XPS 15/15F,
and XRS-5
Relays1)
• Model with 1 relay2)
• Model with 3 relays2)
• Model with 6 relays
Rating 5 A at 250 V AC, non-inductive
1 SPST Form A
2 SPST Form A/1 SPDT Form C
4 SPST Form A/2 SPDT Form C
mA output
• Max. load
• Resolution
0 ... 20 mA or 4 ... 20 mA
750 , isolated
0.1 % of range
Cable
• Transducer and mA output signal
2-core copper conductor, twisted,
shielded, 300 Vrms, 0.82 mm²
(18 AWG), Belden 8 760 or equivalent
is acceptable
• Max. separation between
transducer and transceiver
365 m (1 200 ft)
Displays and controls
100 x 40 mm (4 x 1.5 inch)
multi-block LCD with backlighting
Programming
Programming using handheld
programmer or via PC with
SIMATIC PDM software
Power supply4)
AC version
100 ... 230 V AC ± 15 %, 5
0/60 Hz, 36 VA (17 W)
DC version
12 ... 30 V DC (20 W)
Certificates and approvals
CE, RCM5)
Lloyd's Register of Shipping
ABS Type Approval
FM, CSAUS/C, UL listed
CSAUS/C Class I, Div. 2,
Groups A, B, C and D, Class II,
Div. 2, Groups F and G, Class III
(wall mount only)
• MCERTS Class 3 approved for
Open Channel Flow
Communication
• RS 232 with Modbus RTU or
ASCII via RJ-11 connector
• RS 485 with Modbus RTU or
ASCII via terminal blocks
• Optional: SmartLinx cards for
- PROFIBUS DP
- DeviceNet
Accuracy
Error in measurement
0.25 % of range or 6 mm (0.24 inch),
whichever is greater
Resolution
0.1 % of measuring range or 2 mm
(0.08 inch), whichever is greater3)
Temperature compensation
• -50 ... +150 °C (-58 ... +302 °F)
• Integral temperature sensor in transducer
• External TS-3 temperature sensor
(optional)
• Programmable fixed temperature
values
Rated operating conditions
Installation conditions
• Location
Indoor / outdoor
• Installation category
II
• Pollution degree
4
1)
All relays certified for use with equipment that fails in a state at or under the
rated maximums of the relays
2)
This model is level control only; no open channel flow, differential level or
volume conversion functions
3)
Program range is defined as the empty distance to the face of the transducer plus any range extension
4)
Maximum power consumption is listed
5)
EMC performance available upon request
Ambient conditions
• Ambient temperature (enclosure)
-20 ... +50 °C (-4 ... +122 °F)
•
•
•
•
•
Siemens FI 01 · 2015
4/157
4
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic controllers
HydroRanger 200
Selection and Ordering data
Article No.
Selection and Ordering data
Siemens HydroRanger 200
Ultrasonic level controller for up to six pumps that
provides control, differential control and open
channel flow monitoring. The HydroRanger 200 is
also available as a level measurement controller
only. Select option from number of measurement
points options below.
7ML5034-
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
777 77
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Mounting
Wall mount, standard enclosure
Wall mount, 4 entries, 4 M20 cable glands included
Panel mount1)
4
Power supply
100 ... 230 V AC
12 ... 30 V DC
Number of measurement points
Single point model, 6 relays
Dual point model, 6 relays
Single point model, level only, 1 relay2)
Single point model, level only, 3 relays2)
Communication (SmartLinx)
Without module
SmartLinx PROFIBUS DP module
SmartLinx DeviceNet module
See SmartLinx product on page 4/360 for
more information.
Approvals
General Purpose CE, FM, CSAUS/C, UL listed, RCM
CSA Class I, Div. 2, Groups A, B, C, and D;
Class II, Div. 2, Groups F and G; Class III
(for wall mount applications only)
1
2
3
A
B
Order code
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 27 characters) specify in plain text
Y15
Operating Instructions
Article No.
English
7ML1998-5FC03
French
7ML1998-5FC11
German
Note: The Operating Instructions should be
ordered as a separate item on the order.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
7ML1998-5FC33
Other Operating Instructions
SmartLinx PROFIBUS DP, English
7ML1998-1AQ03
SmartLinx PROFIBUS DP, German
7ML1998-1AQ33
SmartLinx PROFIBUS DP, French
7ML1998-1AQ13
7ML1998-1BH02
0
2
SmartLinx DeviceNet, English
Note: The appropriate SmartLinx Operating
Instructions should be ordered as a separate line
on the order.
3
Accessories
A
B
C
D
1
2
1)
Available with approval option 1 only
2)
This model is level control only; no open channel flow, differential level,
or volume conversion functions.
Handheld programmer
7ML1830-2AK
Tag, stainless steel, 12 x 45 mm (0.47 x 1.77 inch),
one text line, suitable for enclosure
7ML1930-1AC
Sunshield kit, 304 stainless steel
7ML1930-1GA
SITRANS RD100, loop powered display see Chapter 7
7ML5741-...
SITRANS RD200, universal input display with
Modbus conversion - see Chapter 7
7ML5740-...
SITRANS RD300, dual line display with totalizer
and linearization curve and Modbus conversion see Chapter 7
7ML5744-...
SITRANS RD500 web, universal remote monitoring
solution for instrumentation - see Chapter 7
7ML5750-...
Spare parts
4/158
Siemens FI 01 · 2015
Power Supply Board (100 ... 230 V AC)
7ML1830-1MD
Power Supply Board (12 ... 30 V DC)
7ML1830-1ME
Display Board
7ML1830-1MF
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic controllers
HydroRanger 200
■ Dimensional drawings
■ Schematics
Wall mount version
14.9
160.3 (6.325)
(0.58)
15.2
130 (5.125)
(0.6)
Mounting
holes
Ø 4.3
(0.17) (x4)
TB1
See note 1
91
(3.58)
6.6
(0.26)
TB1
TB2
+
240 (9.45)
227 (8.93)
Cover
screws
(x6)
L2/N L1
-
- +
2
TB3
12-30 V
SYNC
1
DC version
+
mA INPUT
+
SHIELD
Relay 1
1
Suitable location for
conduit entrances
Siemens Milltronics
recommends using a hole
punch for drilling the holes.
4 ... 20 mA
OUTPUTS
Relay 2
Housing
Mounting screw
(provided by customer)
Mounting holes
(accessed under lid)
Ø 4.3 (0.17) (x4)
+
+
Relay 3
TS-3
SHIELD
1
Relay 4
36
(1.40)
4
2
Panel mount version
198 (7.80)
+
-
97
(3.82)
Relay 5
DISCRETE
INPUTS
2
COM
278 (10.94)
Relay 6
RS 485
Relays shown in released
state
A
B
Notes
1. Use 2-core copper wire, twisted, with shield, for expansion up to
365 m (1 200 ft.). Route cable in grounded metal conduit, separate
from other cables.
2. Verify that all system components are installed in accordance with
instructions.
HydroRanger 200, dimensions in mm (inch)
3. Connect all cable shields to the HydroRanger 200 shield connections. Avoid differential ground potentials by not connecting cable
shields to ground (earth) anywhere else.
4. Keep exposed conductors on shielded cables as short as possible
to reduce noise on the line caused by stray transmissions and noise
pickup.
HydroRanger 200 connections
Siemens FI 01 · 2015
4/159
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic controllers
SITRANS LU01 and LU02
■ Overview
■ Overview
4
The SITRANS LU01 is an ultrasonic long-range level controller
for liquids and solids in a single vessel up to 60 m (200 ft).
Handheld programmer shown is an accessory and must be
ordered separately.
■ Benefits
■ Benefits
• Single point, long-range level monitoring
• Easy to install; easy to program using removable infrared
keypad (optional)
• Compatible with all EchoMax transducers
• Backlit LCD display with reading in standard engineering units
• Automatic level-to-volume conversion for standard or custom
tank shapes
• Dolphin Plus compatible
• High/low alarms
■ Application
The system consists of a SITRANS LU01 monitor linked to a noncontacting ultrasonic transducer that can be mounted up to
365 m (1 200 ft) away. The SITRANS LU01 will measure distance, level or volume, and it features patented Sonic Intelligence echo processing software for superior reliability.
Readings are displayed in user-selectable linear engineering
units on the backlit LCD.
Modules for popular industrial buses can be factory installed or
added later to meet changing needs. No external gateway is
required, reducing hardware and cabling costs.
• Key Applications: chemical storage, liquid storage,
bulk solids storage (gravel, flour bins, grains, cereals),
plastic pellets
4/160
The SITRANS LU02 is a dual point ultrasonic long-range level
controller for liquids and solids in one or two vessels up to 60 m
(200 ft). Handheld programmer shown is an accessory and must
be ordered separately.
Siemens FI 01 · 2015
• Dual point, long-range level monitoring
• Easy to install; easy to program using removable infrared
keypad (optional)
• Compatible with all EchoMax transducers
• Backlit LCD display with reading in standard engineering units
• Automatic level-to-volume conversion for standard or custom
tank shapes
• Dolphin Plus compatible
• High/low alarms
■ Application
SITRANS LU02 will measure liquids, solids or a combination of
both in one or two vessels of different sizes, shapes and configurations up to 60 m (200 ft).
The system uses ultrasonic technology to measure level, space,
distance, volume or average/differential. It features patented
Sonic Intelligence echo processing software for superior reliability. Transducers can be mounted up to 365 m (1 200 ft) from the
monitor.
Readings are displayed in user-selectable linear engineering
units on the backlit LCD.
• Key Applications: chemical storage, liquid storage,
bulk solids storage (gravel, flour bins, grains, cereals),
plastic pellets, tripper car
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic controllers
SITRANS LU01 and LU02
■ Technical specifications
Mode of operation
Measuring principle
Ultrasonic level measurement
Measuring range
0.3 ... 60 m (1 ... 200 ft)
Measuring points
SITRANS LU01: Max. one point;
SITRANS LU02 Max. two points
Output signal
Ultrasonic transducer
EchoMax series, ST-H transducers
Relays
4 SPDT Form C relays, rated at 5 A at
250 V AC, resistive load
mA output
0/4 ... 20 mA, optically isolated
• Max. load
750 , isolated, 30 V
• Resolution
0.1 % of range
• Outputs
SITRANS LU01: Max. one mA output
SITRANS LU02: Max. two mA outputs
Accuracy
Selection and Ordering data
Article No.
SITRANS LU01/LU02
Single or dual point ultrasonic long-range level
monitoring system for liquids and solids,
and ranges up to 60 m (200 ft).
7ML5004-
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Number of measuring points
LU01 version, 1 point
LU02 version, 2 points
1
2
Input voltage
100/115/200/230 V AC, voltage selector switch
18 ... 30 V DC
Feature software
Standard
A
Resolution
0.1 % of measuring range or 2 mm
(0.08 inch), whichever is greater
Temperature compensation
-50 ... +150 ºC (-58 ... +302 ºF)
• Integral temperature sensor
• External TS-3 temperature sensor
(optional)
• Programmable fixed temperature
ordered as a separate line on the order.
-20 ... +50 ºC (-4 ... +122 ºF)
1)
Available with enclosure option 1 only
2)
Available with enclosure option 3 only
Ambient temperature for enclosure
Design
Weight
2.7 kg (6 lb)
Material (enclosure)
Polycarbonate
Degree of protection (wall mount)
IP65
4
1
Data communications
No module (SmartLinx ready)
0.25 % of range or 6 mm (0.24 inch),
whichever is greater
Ambient conditions
A
B
Application software
Standard
Error in measurement
Rated operating conditions
777 77 77
0
Enclosure
Wall mount
Wall mount, drilled, 6 x M20
Note: Cable glands are not included and should be
Approvals
CE, CSAUS/C, FM1)
CE
ATEX II 3D2)
1
3
A
B
C
Electrical connection
Ultrasonic transducer cable extension RG62-A/U coaxial cable with low
capacitance
2-core copper conductor, twisted,
mA output signal
shielded, 0.5 ... 0.75 mm²
(22 ... 18 AWG), Belden8 760 or
equivalent is acceptable
Copper conductor according to local
Electrical connection and relay
requirements, rated 250 V
connection
Synchronization
5A
Up to 16 LU01/LU02 units can be
synchronized together
Power supply
AC model
100/115/200/230 V AC ± 15 %,
50/60 Hz, 31 VA
DC model
18 ... 30 V DC, 25 W
Displays and controls
51 x 127 mm (2 x 5 inch) graphics
LCD with backlighting
Memory
EEPROM (non-volatile), no backup
battery required
Programming
Using removable programmer
(ordered separately) or
Dolphin Plus (option)
Certificates and approvals
CE, CSAUS/C, FM, ATEX II 3D
Lloyd's register of Shipping
(Categories ENV1, ENV2, ENV3 and
ENV5)
Options
External temperature sensor
TS-3
Communications
• Dolphin Plus: Siemens Windowscompatible interface and
ComVerter link (infrared)
Siemens FI 01 · 2015
4/161
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic controllers
SITRANS LU01 and LU02
Order code
Selection and Ordering data
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
Accessories
Handheld programmer
7ML1830-2AN
Tag, stainless steel, 12 x 45 mm (0.47 x 1.77 inch),
one text line, suitable for enclosures
7ML1930-1AC
M20 cable gland kit (6 M20 cable glands,
6 M20 nuts, 3 stop plugs)
7ML1830-1GM
M20 cable gland kit (4 M20 cable glands,
4 M20 nuts, 4 washers)
7ML1930-1FV
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 27 characters) specify in plain text
Y15
Operating Instructions
SITRANS LU01
Article No.
English
7ML1998-5BE02
TS-3 Temperature Sensor - see TS-3 on page 4/189
7ML1830-2AN
French
7ML1998-5BE12
Sunshield kit, 304 stainless steel
7ML1930-1GA
German
7ML1998-5BE32
Spare parts
Card, LU01 mother main, AC, comm ready
7ML1830-1KX
English
7ML1998-5BD02
Card, LU02 mother main, AC, comm ready
7ML1830-1MA
French
7ML1998-5BD12
Card, LU02 daughter, comm ready
7ML1830-1LP
German
Note: The Operating Instructions should be
ordered as a separate line item.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
7ML1998-5BD32
Card, LU01 daughter, comm ready
7ML1830-1LN
Card, display
See SmartLinx product page 4/360 for
more information.
7ML1830-1LQ
SITRANS LU02
■ Dimensional drawings
106
(4.2)
92
(3.6)
285 (11.2)
267 (10.5)
2
3
267 (10.5)
100
%
209 (8.2)
1
4
0
1
2
3
4
5
6
7
8
9
0
P
P
mA
C
XX
1
2
3
1
2
3
5
6
7
8
9
0
P
P
mA
4
XX
%
SITRANS LU 02
Mounting hole
4.3 (0.17) diameter
access under lid
(4 places)
Suitable location for conduit entrances. Use
water-tight conduit hubs to maintain enclosure
rating.
Dimensional drawings for SITRANS LU01 (left) and SITRANS LU02 (right), dimensions in mm (inch)
Siemens FI 01 · 2015
0
C
SITRANS LU 01
4/162
100
4
%
Suitable location for conduit entrances. Use
water-tight conduit hubs to maintain enclosure
rating.
106
(4.2)
92
(3.6)
285 (11.2)
172 (6.8)
209 (8.2)
%
172 (6.8)
4
Article No.
Selection and Ordering data
Mounting hole
4.3 (0.17) diameter
access under lid
(4 places)
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic controllers
SITRANS LU01 and LU02
■ Schematics
AC model
17
18
1
1
2
Temp. Temp.
sensor sensor
2
16
19
20
21
22
23
24
25
26
2
3
4
Relays
Note 3
27
1
28
Note 2
RS-485
29
2
TX
30
31
1
2
RX
Bi-polar current loop
TX
RX
32
33
SYNC
15
SHLD
14
COM
13
34
RS 232
B A
35
36
37
L2/N L1
Position SW1
for 100/115/
200/230 V AC
Operation
(50/60 Hz
31 VA)
SHLD
1
Note 1
12
COM
mA
outputs
11
SHLD
2
10
SHLD
1
9
SHLD
–
8
SHLD
+
7
BLK
–
6
WHT/SHLD
+
5
BLK
4
BLK
WHT/SHLD
3
WHT/SHLD
BLK
2
WHT/SHLD
Note 4
1
RS 485
DC model
17
18
1
1
2
Temp. Temp.
sensor sensor
2
16
19
20
21
22
23
24
25
26
2
3
4
Relays
Note 3
27
1
28
Note 2
29
2
TX
30
31
1
2
RX
Bi-polar current loop
TX
RX
32
33
SYNC
15
SHLD
14
COM
13
SHLD
1
Note 1
12
COM
mA
outputs
11
SHLD
2
10
SHLD
1
9
SHLD
–
8
RS 232
B A
SHLD
+
7
BLK
–
6
WHT/SHLD
+
5
BLK
4
BLK
WHT/SHLD
3
WHT/SHLD
BLK
2
WHT/SHLD
Note 4
1
34
35
36
37
–
+
4
24 V
Notes:
1. Optically isolated, 750 Ω max. load
2. Use RG62-A/U coaxial (or equivalent) for extensions up to 365 m (1 200 ft).
Run in grounded metal conduit, separate from other wiring.
3. Each relay has 1 set of Form 'C' (SPDT) contacts, relay rated at 5 A 250 V AC, non-inductive, when equal or lower rated
limiting fuses are installed.
4. Required if mounted adjacent to other SITRANS LU01 units or other specified Siemens Milltronics devices. Interconnect
all 'SYNC' terminals with a single 18 AWG (0.5mm 2) wire.
SITRANS LU01 connections
AC model
17
18
19
20
21
22
23
24
25
26
2
3
4
Relays
Note 3
27
1
28
2
TX
Note 2
29
30
31
1
2
RX
Bi-polar current loop
TX
RX
RS-232
B A
32
33
SYNC
16
1
1
2
Temp. Temp.
sensor sensor
2
15
SHLD
14
SHLD
13
SHLD
1
Note 1
12
COM
mA
outputs
11
COM
2
10
SHLD
1
9
SHLD
–
8
SHLD
+
7
WHT/SHLD
–
6
BLK
+
5
WHT/SHLD
4
BLK
WHT/SHLD
3
WHT/SHLD
BLK
2
BLK
Note 4
1
34
35
36
37
L2/N L1
Position SW1
for 100/115/
200/230 V AC
Operation
(50/60 Hz
31 VA)
RS-485
DC model
2
1
2
Temp. Temp.
sensor sensor
16
17
18
19
20
21
22
23
24
25
26
1
2
3
Relays
Note 3
Note 2
4
27
1
28
2
TX
29
30
31
1
2
RX
Bi-polar current loop
TX
RX
32
33
SYNC
15
SHLD
14
SHLD
1
13
SHLD
Note 1
12
COM
mA
outputs
11
COM
2
10
SHLD
1
9
SHLD
–
8
SHLD
+
7
WHT/SHLD
–
6
BLK
+
5
WHT/SHLD
4
BLK
WHT/SHLD
3
WHT/SHLD
BLK
2
BLK
Note 4
1
RS-232
B A
34
35
36
37
–
+
24 V
RS-485
Notes:
1. Optically isolated, 750 Ω max. load
2. Use RG62-A/U coaxial (or equivalent) for extensions up to 365 m (1 200 ft).
Run in grounded metal conduit, separate from other wiring.
3. Each relay has 1 set of Form 'C' (SPDT) contacts, relay rated at 5 A 250 V AC, non-inductive, when equal or lower rated
limiting fuses are installed.
4. Required if mounted adjacent to other SITRANS LU01 units or other specified Siemens Milltronics devices. Interconnect
all 'SYNC' terminals with a single 18 AWG (0.5 mm 2) wire.
SITRANS LU02 connections
Siemens FI 01 · 2015
4/163
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic controllers
SITRANS LU10
■ Overview
■ Benefits
• Ten point, long-range level monitoring
• Automatic level-to-volume conversion for standard or custom
tank shapes
• Dolphin Plus compatible
• Backlit LCD display with reading in standard engineering units
• Easy to install, easy to program using removable infrared
keypad (optional)
■ Application
It can be used in a wide range of applications to scan liquids,
solids or a combination of both contained in vessels of differing
size, shape, and configuration up to 60 m (200 ft).
4
SITRANS LU10 is an ultrasonic long-range level monitor for
liquids and solids, offering 10-point monitoring in a single unit.
Handheld programmer shown is an accessory and must be
ordered separately.
4/164
Siemens FI 01 · 2015
SITRANS LU10 uses ultrasonic technology to measure level,
space, distance, volume, or average/differential. Transducers
can be mounted up to 365 m (1 200 ft) from the monitor.
The SITRANS LU10 features patented Sonic Intelligence echo
processing software for superior reliability. Readings are displayed in user-selectable linear engineering units on the LCD.
• Key Applications: chemical storage, liquid storage, bulk
solids storage (sugar, flour bins, grains, cereals), plastic
pellets, tank farms
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic controllers
SITRANS LU10
■ Technical specifications
Power supply
100/115/200/230 V AC ± 15 %,
50/60 Hz, 31 VA
Displays and controls
51 x 127 mm (2 x 5 inch) graphics
LCD with backlighting
Max. 10
Memory
EEPROM (non-volatile), no backup
battery required
Ultrasonic transducer
EchoMax series, ST-H transducers
Programming
Relays
SPDT Form C relays, rated 5 A at
250 V AC, resistive load
Using removable programmer
(ordered separately) or Dolphin Plus
(option)
Certificates and approvals
mA output
SITRANS LU A0 module (option):
0/4 ... 20 mA, optically isolated
• Max. load
750 , isolated
• CE, RCM, FM, CSAUS/C , ATEX II 3D
• Lloyd's register of Shipping
(Categories ENV1, ENV2, ENV3 and
ENV5)
• Resolution
0.1 % of range
Mode of operation
Measuring principle
Ultrasonic level measurement
Measuring range
Max. 0.3 ... 60 m (1 ... 200 ft)
Measuring points
Output
Options
Expansion card
Accuracy
Error in measurement
0.25 % of range or 6 mm (0.24 inch),
whichever is greater
Resolution
0.1 % of measuring range or 2 mm
(0.08 inch), whichever is greater
Temperature compensation
-50 ... +150 °C (-58 ... +302 °F)
• Integral temperature sensor
• External TS-3 temperature sensor
(expandable to 10 inputs with
optional TIB-9 card)
• Programmable fixed temperature
• External temperature sensor
• Communications
• I/O devices
TIB-9, increases the number of
TS-3 inputs from 1 ... 10
TS-3
• Dolphin Plus: Siemens Windowscompatible interface and
ComVerter link (infrared)
• Max. 3 I/O devices per
SITRANS LU10
• SITRANS LU AO analog output
module (max. 1)
Rated operating conditions
Ambient conditions
Ambient temperature for enclosure
-20 ... +50 °C (-4 ... +122 °F)
Design
Weight
2.7 kg (6 lb)
Material (enclosure)
Polycarbonate
Degree of protection (wall mount)
IP65/Type 4X/NEMA 4X
Electrical connection
Ultrasonic transducer
RG62-A/U coaxial cable with low
capacitance
Signal transmission
2-core copper conductor, twisted,
shielded, 0.5 ... 0.75 mm²
(22 ... 18 AWG), Belden 8760 or
equivalent is acceptable
Electrical connection and relay
connection
Copper conductor according to local
requirements, rated 250 V 5 A
Synchronization
Up to 16 LU10 units can be synchronized together
Siemens FI 01 · 2015
4/165
4
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic controllers
SITRANS LU10
Selection and Ordering data
Article No.
Selection and Ordering data
SITRANS LU10
Ten point ultrasonic long-range level monitoring
system for liquids and solids applications,
and ranges up to 60 m (200 ft).
7ML5007-
Further designs
7 7 7 7 7 - 77
Please add "-Z" to Article No. and specify Order
code(s).
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Input voltage
100/115, 200/230 V AC, selectable
Feature software
Standard
Application software
Standard
Data communications
No module (SmartLinx ready)
4
TIB-9 temperature card
None
With TIB-9 card
Enclosure
Wall mount
Wall mount, drilled, 12 x M20 x1.5 for cable glands
Note: Cable glands are not included and should be
ordered as a separate line on the order.
Approvals
CE, CSAUS/C, FM1)
ATEX II 3D1)
CE, RCM2)
1)
2)
Available with enclosure option 1 only
Available with enclosure option 2 only
4/166
Siemens FI 01 · 2015
1
A
A
Order code
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 27 characters) specify in plain text
Y15
Operating Instructions
Article No.
English
7ML1998-5AN02
French
7ML1998-5AN12
German
7ML1998-5AN32
Accessories
0
0
1
1
2
A
B
D
Handheld programmer
7ML1830-2AN
Tag, stainless steel, 12 x 45 mm (0.47 x 1.77 inch),
one text line, suitable for enclosures
7ML1930-1AC
Temperature Card TIB 9-card
7ML1830-1CN
M20 cable gland kit (6 M20 cable glands,
6 M20 nuts, 3 stop plugs)
7ML1830-1GM
M20 cable gland kit (4 M20 cable glands,
4 M20 nuts, 4 washers)
7ML1930-1FV
TS-3 Temperature Sensor - see TS-3 on page 4/189
Sunshield kit, 304 stainless steel
7ML1930-1GA
Spare parts
Card, mother main, AC, comm ready
7ML1830-1ML
Card, daughter, comm ready
7ML1830-1LY
Card, display
See SmartLinx product on page 4/360 for more
information.
7ML1830-1LQ
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic controllers
SITRANS LU10
■ Dimensional drawings
106
(4.2)
92
(3.6)
285 (11.2)
267 (10.5)
1
2
3
4
5
6
7
8
9
100
10
172 (6.8)
209 (8.2)
%
0
1
2
3
5
6
7
8
9
0
P
P
mA
C
4
XX
%
SITRANS LU 10
Suitable location for conduit entrances. Use
water-tight conduit hubs to maintain enclosure
rating.
Mounting hole
4.3 (0.17) diameter
access under lid
(4 places)
4
SITRANS LU10, dimensions in mm (inch)
9
10
transducers
Note 1
To transducers (10 max.) RG62-A/U
coax, 365 m / transducer max.
black
white/shield
black
white/shield
23 24 25 26
10
black
white/shield
9
36 37 38 39 40
Temp.
sensor
41 42 43 44 45 46 47 48 49 50 51 52
SYNC
2
black
1
3
white/shield
18 19 20 21 22
black
white/shield
4
black
white/shield
3
black
white/shield
2
black
white/shield
1
2
black
white/shield
■ Schematics
1
2
TX
1
2
RX
P12
V
Peripheral
communication
2
3
9
10
Note 3
Note 2
L2/N L1
Position SW1
for 100/115/
200/230 V
AC
Operation
(50/60 Hz,
15 VA)
Notes:
1. Transducer cables must be run in a grounded metal conduit separate from other wiring (except TS-3 temperature sensor wiring, if
applicable).
2. Optional TIB-9 card for multiple temperature sensors. Do not jump the terminals if TS-3s are not used.
3. The SITRANS LU10 is compatible with the following Siemens Milltronics peripherals:
- SITRANS LU AO - analog output module
SITRANS LU10 connections
Siemens FI 01 · 2015
4/167
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic controllers
SITRANS LU AO
■ Overview
■ Technical specifications
Mode of operation
Input
Communications
Transmission rate
Voltage
Polarization
Max. load
Output
Analog outputs
± 20 mA bipolar current loop
• Max. load
• Resolution
Data from SITRANS LU10
4 800 bits/s
± 20 mA bipolar current loop
Non-polarized
1 receiving unit
10 analog outputs, programmable
from SITRANS LU10
0 or 4 ... 20 mA, isolated
Input and transmission
750 
0.1 %
Rated operating conditions
4
Ambient conditions
The SITRANS LU AO Analog Output Module provides remote
analog output for the measurement points of the SITRANS LU10
level monitor.
Ambient temperature for enclosure
Location
Installation category
Pollution degree
-20 ... +50 °C (-5 ... +122 °F)
Indoor/outdoor
II
4
Design
■ Benefits
• Analog outputs can be up to 1 500 m (5 000 ft) from the
SITRANS LU 10
• Analog outputs can be per transducer and/or average of 2 or
more
■ Application
The operation of the SITRANS LU AO is programmed via the
SITRANS LU10. The only on-board settings are for bank selection and output testing.
The SITRANS LU AO can provide up to 10 analog outputs
(each sharing a common negative bus which is electrically
isolated from ground).
Weight
2 kg (4.4 lb)
Material (enclosure)
Polycarbonate
Degree of protection
Cable connection
Type 4X/NEMA 4X/IP65
2 copper conductors, twisted,
with foil shield/drain wire, 300 V
0.5 ... 0.75 mm² (22 ... 18 AWG)
Copper conductor according to
local requirements,
Electrical connection and relay
connection
rated 250 V 5 A
Power supply
100/115/200/230 V AC ± 15 %,
50/60 Hz, 15 VA
Displays and controls
1 LED for display of voltage/
communications state
Certificates and approvals
CE, FM, CSAUS/C , RCM
Selection and Ordering data
Article No.
SITRANS LU AO
Provides remote analog output for the
measurement points of the SITRANS LU10
level monitor.
Approvals: CSAUS/C, FM, CE, RCM
7ML5810-1A
Operating Instructions
English
7ML1998-5CE01
German
Note: Operating Instructions should be
ordered as a separate line item on the order.
7ML1998-5CE31
This device is shipped with the Siemens Milltronics
manual DVD containing the Quick Start and Operating Instructions library.
Accessories
Sun Shield, 304 stainless steel
4/168
Siemens FI 01 · 2015
7ML1930-1GA
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic controllers
SITRANS LU AO
■ Dimensional drawings
209
(8.2)
16
(0.6)
91
(3.6)
Lid screws
(6 places)
172
(6.8)
285
(11.2)
267
(10.5)
4
SITRANS LU AO
Lid
Suitable location for
conduit entrances
Mounting holes
(accessed under lid)
4.3 mm (0.17 inch) diameter
4 places
Enclosure
Mounting screw (by customer)
SITRANS LU AO, dimensions in mm (inch)
■ Schematics
230 V
200 V
OFF
Switch is shown in OFF position.
Select appropriate voltage.
115 V
100 V
See note 1
mA
output
spare
Bi-polar
Receiver
1
2
3
SW3
See note 2
4
+
1_
5
6
7
mA
output
+
2_
8
9
+
3_
+
mA
output
4_
+
5_
mA
output
+
6_
+
7_
mA
output
+
8_
+
9_
+
10_
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29
L2
/N L1
30 31 32
See note 3
Isolated 0/4 ... 20 mA out,
750 Ω load max. (typical of 10)
100/115/200/230 V AC
50/60 Hz select
voltage via switch
Notes:
1. SITRANS LU AO receiver input is non-polarized.
2. Refer to associated application device instruction manual for wiring detail. Check that the communication parameter P740 (SITRANS LU10) is ON.
3. SITRANS LU AO interconnecting cable shield should be grounded at SITRANS LU10 only. Insulate shields at junctions to prevent inadvertent
grounding. Maximum individual loop length is 3 000 m (10 000 ft).
SITRANS LU AO connections
Siemens FI 01 · 2015
4/169
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic transducers
Ultrasonic transducers
■ Overview
Ultrasonic Transducers
Ultrasonic measuring systems are the cost-effective choice for
monitoring and control in short- to long-range applications for
liquids, slurries, and solids in a wide range of industries. Transducers are impervious to dust, moisture, corrosion, vibration,
flooding, and extreme temperature. They are easy to install and
virtually maintenance-free. Choose from a wide selection of
models designed for short or long range applications on liquids
or solids.
■ Technical specifications
EchoMax Transducers
Liquids
4
Liquids and Solids
Standard
XRS-5
ST-H
XPS-10
XPS-15
XPS-30
Max. range1)
8m
(26 ft)
10 m
(33 ft)
10 m
(33 ft)
15 m
(50 ft)
30 m
(100 ft)
Min. range
0.3 m
(1 ft)
0.3 m
(1 ft)
0.3 m
(1 ft)
0.3 m
(1 ft)
0.6 m
(2 ft)
Max. temperature
65 °C
(149 °F)
73 °C
(164 °F)
95 °C
(203 °F)
95 °C
(203 °F)
95 °C
(203 °F)
Min. temperature
-20 °C
(-4 °F)
-40 °C
(-40 °F)
-40 °C
(-40 °F)
-40 °C
(-40 °F)
-40 °C
(-40 °F)
Typical Applications
Wet wells and open
channels
Chemical storage and
liquid tanks
Dusty solids and slurries Deep wet wells and
solids
Powders, pellets and
solids
Frequency
44 kHz
44 kHz
44 kHz
44 kHz
30 kHz
Beam angle (-3dB)
10°
12°
12°
6°
6°
Thread size
R 1" [(BSPT),
EN 10226]
1" NPT
1" and 2" NPT
R 2" [(BSPT),
EN 10226],
2" [(BSPP),
EN ISO 228-1]
R 1" [(BSPT),
EN 10226]
1" NPT
R 1" [(BSPT),
EN 10226]
1" NPT
R 1.5" [(BSPT),
EN 10226]
Universal thread
1.5" NPT
Enclosure
• PVDF Copolymer
• CSM
• Option: Flange with
PTFE facing
• ETFE
• Option: PVDF
• PVDF
• PVDF
• PVDF
• Option: Foam facing
• Option: Foam facing
• Option: Foam facing
• Flange with PTFE facing • Flange with PTFE facing • Flange with PTFE facing
SITRANS LUT400
•
•
•
•
•
SITRANS LU
•
•
•
•
•
HydroRanger 200
•
•
•
•
MultiRanger 100/200
•
•
•
•
Compatible with:
1)
Application conditions such as extreme dust or angle of repose may reduce the usable maximum range.
Consult your local Siemens representative for further information.
4/170
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic transducers
ST-H
■ Overview
■ Technical specifications
Mode of operation
Measuring principle
Ultrasonic transducer
Input
Measuring range
0.3 ... 10 m (1 ... 33 ft)
Output
Frequency
44 kHz
Beam angle
12°
Accuracy
Temperature compensation
Compensated by integral
temperature sensor
Rated operating conditions
Pressure
Ambient conditions
• Ambient temperature
ST-H transducers use ultrasonic technology to measure level in
chemical storage and liquid tanks.
■ Benefits
• Can be mounted on a narrow standpipe
• Immune to corrosive and harsh environments
• Integral temperature sensor
■ Application
The narrow design of the ST-H allows the transducer to be
mounted on a narrow standpipe. When mounted correctly, it is
completely protected from the process and can even be used in
harsh, corrosive environments.
During operation, the ultrasonic transducer emits acoustic
pulses in a narrow beam perpendicular to the transducer face.
The level transceiver measures the propagation time between
pulse emission and reception of the echo to calculate the distance from the transducer to the material. Variations in sound
velocity due to changes in temperature within the permissible
range are automatically compensated by the integral temperature sensor.
• Key Applications: chemical storage, liquid tanks
Normal atmospheric pressure
-20 ... +60 °C (-5 ... +140 °F)
(ATEX approved model)
-40 ... +73 °C (-40 ... +163 °F)
(CSA/FM approved model)
Design
Weight1)
1.4 kg (3 lb)
Material (enclosure)
Base and lid made of ETFE or PVDF
(epoxy fitted joint)2)
Process connection
2" NPT [(Taper), ANSI/ASME B1.20.1],
R 2" [(BSPT), EN 10226] or
G 2" [(BSPP), EN ISO 228-1]
Degree of protection
IP68
Cable connection
2-core shielded/twisted, 0.519 mm²
(20 AWG), PVC sheath
Cable (max. length)
365 m (1 200 ft) with RG 62 A/U
coaxial cable
Options
• Flange adapter
Certificates and approvals
3" Universal (fits DN 65, PN 10 and
3" ASME)
CE, CSA Class I, II, III, Div. 1,
Groups A, B, C, D, E, F, G T3
(ETFE only), FM Class I, II, Div. 1,
Groups C, D, E, F, G T4A,
ATEX II 2G / INMETRO Ex mb IIC T5
Gb, RCM, KCC
1)
Approximate shipping weight of transducer with standard cable length
2)
When measuring chemicals, check compatibility of ETFE or PVDF and
epoxy, or mount joint external to process.
Siemens FI 01 · 2015
4/171
4
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic transducers
ST-H
Selection and Ordering data
Article No.
Selection and Ordering data
EchoMax ST-H ultrasonic transducer
Level measurement in chemical storage and liquid
tanks. The narrow design of the ST-H allows the
transducer to be mounted on a 2 inch standpipe.
Measuring range: min. 0.3 m (1 ft), max. 10 m
(33 ft).
7ML1100-
Further designs
77 A 7 0
Please add "-Z" to Article No. and specify Order
code(s).
Acrylic coated, stainless steel tag [13 x 45 mm
(0.5 x 1.75 inch)]: Measuring-point number/
identification (max. 16 characters) specify in
plain text
Y17
Accessories
Article No.
0
1
2
Universal box bracket, mounting kit
7ML1830-1BK
3" ASME, DN 65 PN 10, JIS 10K 3B ETFE flange
adapter for 2" NPT
7ML1830-1BT
3
3" ASME, DN 65 PN 10, JIS 10K 3B ETFE flange
adapter for 2" BSPT
7ML1830-1BU
4
5
Easy Aimer 2, NPT with ¾" x 1" PVC coupling
7ML1830-1AQ
Easy Aimer 2, aluminum with M20 adapter and
1" and 1½" BSPT aluminum couplings
7ML1830-1AX
Easy Aimer 304, with stainless steel coupling
7ML1830-1AU
Easy Aimer 304, with M20 adapter and 1" and
1½" BSPT 304 stainless steel couplings
7ML1830-1GN
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Process connection
ETFE, 2" NPT [(Taper), ANSI/ASME B1.20.1]
ETFE, R 2" [(BSPT), EN 10226]
ETFE, G 2" [(BSPP), EN ISO 228-1]
4
PVDF copolymer, 2" NPT [(Taper), ANSI/ASME
B1.20.1]
PVDF copolymer, R 2" [(BSPT), EN 10226]
PVDF copolymer, G 2" [(BSPP), EN ISO 228-1]
Cable length
5 m (16.40 ft)
10 m (32.81 ft)
30 m (98.43 ft)
A
B
C
50 m (164.04 ft)
100 m (328.08 ft)
D
E
Approvals
CE, FM Class I, II, Div. 1, Groups C,D,E,F,G T4A
ATEX 2G / INMETRO Ex mb IIC T5 Gb, RCM, KCC
CSA Class I, II, III, Div. 1, Groups A,B,C,D,E,F,G T3
CE, ATEX 2G / INMETRO Ex mb IIC T5 Gb, RCM,
KCC
2
3
4
Operating Instructions
Article No.
Quick Start Manual, multi-language
A5E32105880
Applications Guidelines, multi-language
Note: The Applications Guidelines should be
ordered as a separate line item on the order.
7ML1998-5HV61
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
1)
Available with Process connection options 0 ... 2 only
2)
Available with Process connection options 3 ... 5 only
3)
Not suitable for Ketone, Hexane, Ester or Ethyl Acetate atmospheres
4/172
Siemens FI 01 · 2015
Order code
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic transducers
ST-H
■ Dimensional drawings
Coupling
119 (4.7)
22
(0.87)
74 (2.9)
Mounting thread
(process
connection)
Flange Adapter
20.9
(0.82)
1" NPT
Conduit
thread
Siemens Milltronics
flange adapter
82 (3.2)
87 (3.4)
Diameter
4
ST-H ultrasonic transducer, dimensions in mm (inch)
■ Schematics
Direct connection
Black
White
Shield
Coaxial extension
White
Shield
3 Terminal direct*
Black
White
Shield
3 Terminal extension*
Black
White
Shield
* For SITRANS LUT400, MultiRanger 100/200, HydroRanger 200
ST-H ultrasonic transducer connections
Siemens FI 01 · 2015
4/173
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic transducers
EchoMax XRS-5
■ Overview
■ Technical specifications
Mode of operation
Measuring principle
Ultrasonic transducer
Input
Measuring range
0.3 ... 8 m (1 ... 26 ft), dependent on
application
Output
Frequency
44 kHz
Beam angle
10°
Accuracy
Temperature error
Compensated by integral
temperature sensor
Rated operating conditions
4
EchoMax XRS-5 ultrasonic transducer provides reliable, continuous level monitoring of liquids and slurries in narrow lift stations/
wet wells, flumes, weirs and filter beds using a beam angle of
just 10° and a CSM rubber face.
■ Benefits
• Narrow beam angle of only 10°
• Chemically resistant PVDF copolymer enclosure and CSM
rubber face
• Measuring range: 8 m (26 ft) for measurement of liquids and
slurries
• Fully submersible: IP68 degree of protection
• Easy installation with 1" NPT or R 1" BSPT connection
■ Application
The XRS-5 is non-contacting with a measuring range from
0.3 ... 8 m (1 ... 26 ft). Advanced echo processing ensures reliable data even in conditions with obstructions, turbulence and
foam.
The hermetically sealed CSM rubber face and the PVDF copolymer enclosure are designed for maximum resistance to methane, salt water, caustics and harsh chemicals common to wastewater installations. With an IP68 degree of protection, this
rugged sensor is fully submersible in the event of flood conditions. Use a submergence shield if full submergence is possible
in the application. A submergence shield will maintain a high
level reading output during submerged conditions.
The low-cost XRS-5 transducer is compatible with a full range of
Siemens controllers, from a basic system for high/low alarm or
simple pump control, up to advanced control systems with communications, telemetry and SCADA integration capabilities.
• Key Applications: wet wells, flumes, weirs, filter beds
4/174
Siemens FI 01 · 2015
Vessel pressure
Normal atmospheric pressure
Ambient conditions
• Ambient temperature
-20 ... +65 °C (-4 ... +149 ° F)
Design
Weight (approximate shipping weight
of sensor with standard cable length)
1.2 kg (2.6 lb)
Material (enclosure)
PVDF copolymer enclosure and
CSM face
Process connection
1" NPT [(Taper), ANSI/ASME B1.20.1]
or R 1" [(BSPT), EN 10226]
Degree of protection
IP65/IP68
Cable connection
2-core shielded/twisted, 0.5 mm2
(20 AWG), PVC sheath
Cable (max. length)
• 365 m (1 200 ft) with RG 62 A/U
coaxial cable
• 365 m (1 200 ft) with 2-core twisted
pair, foil shield, 0.5 mm2
(20 AWG), PVC sheath, only for
MultiRanger 100/200
Options
Flange version
Factory flange with PTFE face for
ASME, EN or JIS configuration
Submergence shield
For applications with flooding possible
Certificates and approvals
CE, RCM, KCC
CSA Class I, Div. 2, Groups A,B,C,D,
Class II, Div. 1 Groups E,F,G
FM Class I, Zone 1, AEx m IIC, T6
Class II, III, Div. 1, Groups E,F,G T6
ATEX II 2GD / IECEx / INMETRO
Ex mb IIC T6 Gb, Ex tb IIIC T85 °C
Db
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic transducers
EchoMax XRS-5
Order code
Selection and Ordering data
Article No.
Selection and Ordering data
EchoMax XRS-5 transducer
With a beam angle of 10°, the XRS-5 provides
reliable, continuous level monitoring of liquids and
slurries in narrow lift stations/wet wells, flumes,
weirs and filter beds.
Measuring range: min. 0.3 m (1 ft), max. 8 m (26 ft)
7ML1106-
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
777 7 0 - 0 7
Acrylic coated, stainless steel tag [13 x 45 mm
(0.5 x 1.75 inch)]: Measuring-point number/
identification (max. 16 characters) specify in
plain text
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Process connection
1" NPT [(Taper), ANSI/ASME B1.20.1]
R 1" [(BSPT), EN 10226]
¢ 1
¢ 2
Cable length
5 m (16.40 ft)
10 m (32.81 ft)
30 m (98.43 ft)
¢
¢
Facing
Standard (CSM rubber)
PTFE (flange versions)
¢
Approvals
CE, RCM, KCC, CSA Class I, Div. 2, Groups
¢
A,B,C,D, Class II, Div. 1 Groups E,F,G
FM Class I, Zone 1, AEx m IIC, T6 Class II, III, Div.
1, Groups E,F,G T6 ATEX II 2GD / IECEx /
INMETRO Ex mb IIC T6 Gb, Ex tb IIIC T85 °C Db
Mounting flange (flush mount)
None
A
B
C
A
B
2
¢
A
3" ASME, 150 lb, flat faced
4" ASME, 150 lb, flat faced
6" ASME, 150 lb, flat faced
B
C
D
DN 80, PN 10/16, Type A, flat faced
DN 100, PN 10/16, Type A, flat faced
DN 150, PN 10/16, Type A, flat faced
J
K
L
JIS10K 3B style
JIS10K 4B style
JIS10K 6B style
Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5 or EN 1092-1, or JIS B 2220 standard.
Q
R
S
Operating Instructions
Article No.
Quick Start Manual, multi-language
A5E32299685
Applications Guidelines, multi-language
Note: The Applications Guidelines should be
ordered as a separate line item on the order.
7ML1998-5HV61
¢ Y17
Accessories
Article No.
Tag, stainless steel with hole,
12 x 45 mm (0.47 x 1.77 inch),
one text line for fastening on sensors
7ML1930-1BJ
Submergence shield kit
7ML1830-1BH
Easy Aimer 2, NPT with ¾" x 1" PVC coupling
7ML1830-1AQ
Easy Aimer 2, aluminum with M20 adapter and
1" and 1½" BSPT aluminum couplings
7ML1830-1AX
Easy Aimer 304, with stainless steel coupling
7ML1830-1AU
Easy Aimer 304, with M20 adapter and 1" and
1½" BSPT 304 stainless steel couplings
7ML1830-1GN
FMS-200 universal box bracket, mounting kit
7ML1830-1BK
FMS-210 channel bracket, wall mount
7ML1830-1BL
FMS-220 extended channel bracket, wall mount
7ML1830-1BM
FMS-310 channel bracket, floor mount
7ML1830-1BN
FMS-320 extended channel bracket, floor mount
7ML1830-1BP
FMS-350 bridge channel bracket, floor mount
(see Mounting Brackets on page 4/187 for
more information)
7ML1830-1BQ
1" NPT locknut, plastic
7ML1830-1DS
1" BSPT locknut, plastic
7ML1830-1DR
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Siemens FI 01 · 2015
4/175
4
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic transducers
EchoMax XRS-5
Selection and Ordering data
Article No.
Selection and Ordering data
EchoMax XRS-5C transducer
With a beam angle of 10°, the XRS-5 provides
reliable, continuous level monitoring of liquids and
slurries in narrow lift stations/wet wells, flumes,
weirs and filter beds.
Measuring range: min. 0.3 m (1 ft), max. 8 m (26 ft)
7ML1105-
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
777 7 1 - 0 7
Acrylic coated, stainless steel tag [13 x 45 mm
(0.5 x 1.75 inch)]: Measuring-point number/
identification (max. 16 characters) specify in
plain text
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Process connection
1" NPT [(Taper), ANSI/ASME B1.20.1]
Cable length
5 m (16.40 ft)
10 m (32.81 ft)
30 m (98.43 ft)
4
Facing
Standard (CSM rubber)
PTFE (flange versions)
¢ 1
¢
¢
¢
Approvals
CSA Class I Div. 1, Group A,B,C,D; Class II Div. 1, ¢
Group E,F,G; Class III
Mounting flange (flush mount)
None
A
B
C
A
B
1
¢
A
B
C
D
3" ASME, 150 lb, flat faced
4" ASME, 150 lb, flat faced
6" ASME, 150 lb, flat faced
Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5 or EN 1092-1, or JIS B 2220 standard.
Operating Instructions
Article No.
Quick Start Manual, multi-language
A5E32299685
Applications Guidelines, multi-language
Note: The Applications Guidelines should be
ordered as a separate line item on the order.
7ML1998-5HV61
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
4/176
Siemens FI 01 · 2015
Order code
¢ Y17
Accessories
Article No.
Submergence shield kit
7ML1830-1BH
Easy Aimer 2, NPT with ¾" x 1" PVC coupling
7ML1830-1AQ
Easy Aimer 304, with stainless steel coupling
7ML1830-1AU
FMS-200 universal box bracket, mounting kit
7ML1830-1BK
FMS-210 channel bracket, wall mount
7ML1830-1BL
FMS-220 extended channel bracket, wall mount
7ML1830-1BM
FMS-310 channel bracket, floor mount
7ML1830-1BN
FMS-320 extended channel bracket, floor mount
7ML1830-1BP
FMS-350 bridge channel bracket, floor mount
(see Mounting Brackets on page 4/187 for
more information)
7ML1830-1BQ
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic transducers
EchoMax XRS-5
■ Dimensional drawings
■ Schematics
Direct connection
Submergence Shield
(optional)
White/shield
Black/hot
Black
White
155 (6.1)
127 (5.0)
25
(0.98)
Standard
Shield
89 (3.5)
Coaxial extension
Flange (optional)
124 (4.9)
4
127 (5.0)
Junction box
Extend cable using RG-62 A/U coax.
3 terminal direct*
ANSI, DIN, or JIS
Mounting:
Suspended Conduit
Bracket
Rigid metal
conduit
Black
White
Flexible
conduit
Steel
channel
Shield
Non-metallic
coupling
3 terminal extension*
Non-metallic
coupling
Black
White
Transducer
Shield
* For SITRANS LUT400, MultiRanger 100/200, HydroRanger 200
Flexible conduit transducer should not be
subjected to wind, vibration or jarring.
Plywood
XRS-5 ultrasonic transducer connections
Submersible
Non-metallic
coupling
Rigid metal
conduit
Non-metallic
coupling
Submergence
shield
Plywood mounting provides
excellent isolation
(must be rigid).
Transducer with submergence shield, used in
applications where flooding is possible.
XRS-5 ultrasonic transducer, dimensions in mm (inch)
Siemens FI 01 · 2015
4/177
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic transducers
EchoMax XPS
■ Overview
■ Benefits
•
•
•
•
•
•
Integral temperature compensation
Low ringing effect reduces blanking distance
Optional foam facing for dusty applications
Self-cleaning and low-maintenance
Chemically resistant
Hermetically sealed
■ Application
XPS transducers can be fully immersed, are resistant to steam
and corrosive chemicals, and can be installed without flanges.
The XPS series offers versions for various measuring ranges up
to 30 m (100 ft) and up to a max. temperature of 95 °C (203 °F).
4
EchoMax XPS transducers use ultrasonic technology to measure level in a wide range of liquids and solids.
4/178
Siemens FI 01 · 2015
During operation, the EchoMax transducers emit acoustic
pulses in a narrow beam. The level monitor measures the propagation time between pulse emission and its reflection (echo) to
calculate the distance.
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic transducers
EchoMax XPS
■ Technical specifications
Input
XPS-10
XPS-15 (standard and F models)
XPS-30
Measuring range
0.3 ... 10 m
(1 ... 33 ft)
Standard:
0.6 ... 30 m
(2 ... 100 ft)
0.3 ... 15 m
(1 ... 50 ft)
XPS-15F:
0.45 ... 15 m
(1.5 ... 50 ft)
Output
Frequency
44 kHz
44 kHz
30 kHz
Beam angle
12°
6°
6°
-40 ... +95 °C
XPS-15F:
-40 ... +95 °C
(-40 ... +203 °F)
-20 ... +95 °C
(-40 ... +203 °F)
Environmental
Location
Ambient temperature
Indoors/outdoors
4
(-4 ... +203 °F)
Pollution degree
4
Pressure
8 bar g (120 psi g)
8 bar g (120 psi g)
Flanged:
Flanged:
Flanged:
0.5 bar g (7.25 psi g)
0.5 bar g (7.25 psi g)
0.5 bar g (7.25 psi g)
0.8 kg
(1.8 lb)
1.3 kg (2.8 lb)
4.3 kg
(9.5 lb)
0.5 bar g (7.25 psi g)
Design
Weight
Flanged:
2 kg (4.4 lb)
Power supply
Operation of transducer only with approved Siemens Milltronics controllers
Material
Standard:
Standard:
Standard:
PVDF
PVDF
PVDF
Flanged:
Flanged:
Flanged:
PVDF with CPVC flange
PVDF with CPVC flange
PVDF with CPVC flange
Option:
Color
Option:
Option:
PTFE face with CPVC flange
PTFE face with CPVC flange
PTFE face with CPVC flange
Blue
Standard:
Blue
Blue
XPS-15F:
Gray
Process connection
1" NPT or 1" BSPT
Standard:
1.5" universal thread (NPT or BSPT)
1" NPT or 1" BSPT
XPS-15F:
1" NPT
Degree of protection
IP66/68
Cable
2 wire twisted pair/braided and foil shielded 0.5 mm² (20 AWG) PVC jacket
Separation
Max. 365 m (1 200 ft)
Certificates and approvals
Standard:
Standard:
CE, CSA, FM, ATEX, IECEx
CE, CSA, FM, ATEX, IECEx
IP66/68
IP66/68
CE, CSA, FM, ATEX, IECEx
XPS-15F:
FM Class I, Div. 1, Groups A, B, C and
D, Class II Div. 1, Groups E, F and G,
Class III
1)
EMC certificate available on request.
Siemens FI 01 · 2015
4/179
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic transducers
EchoMax XPS
Selection and Ordering data
Article No.
Selection and Ordering data
EchoMax XPS-10 ultrasonic transducer
High-frequency ultrasonic transducer designed
for a wide variety of liquid and solid applications,
for use with approved controllers. Includes integral
temperature sensor.
Measuring range: min. 0.3 m, max.10 m
7ML1115-
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
777 7 0
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Mounting thread and facing
1" NPT [(Taper), ANSI/ASME B1.20.1]
1" NPT [(Taper), ANSI/ASME B1.20.1]
with foam facing1)
1" NPT [(Taper), ANSI/ASME B1.20.1]
with PTFE facing2)
4
¢ 0
1
¢ 3
4
5
Cable length
5 m (16.40 ft)
10 m (32.81 ft)
30 m (98.43 ft)
¢
¢
¢
Mounting flange
None
¢
Y15
Operating Instructions
Article No.
Quick Start guide, multi-language
A5E32282889
Applications Guidelines, multi-language
Note: The Applications Guidelines should be
ordered as a separate line item on the order.
7ML1998-5HV61
Accessories
B
C
E
F
K
50 m (164.04 ft)
100 m (328.08 ft)
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring point number/ identification
(max. 27 characters) specify in plain text
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
2
R 1" [(BSPT), EN 10226]
R 1" [(BSPT), EN 10226] with foam facing1)
R 1" [(BSPT), EN 10226] with PTFE facing2)
Order code
A
Tag, stainless steel with hole, 12 x 45 mm
(0.47 x 1.77 inch), one text line for fastening on
sensors
7ML1930-1BJ
Submergence shield kit
7ML1830-1BH
Easy Aimer 2, with ¾" x 1" NPT PVC coupling
7ML1830-1AQ
Easy Aimer 2, aluminum with M20 adapter and
1" and 1½" BSPT aluminum couplings
7ML1830-1AX
Easy Aimer 304, with stainless steel coupling
7ML1830-1AU
Easy Aimer 304, with M20 adapter and 1" and
1½" BSPT 304 stainless steel couplings
7ML1830-1GN
3" ASME, 150 lb, flat faced
4" ASME, 150 lb, flat faced
C
D
Universal box bracket, mounting kit
7ML1830-1BK
6" ASME, 150 lb, flat faced
8" ASME, 150 lb, flat faced
E
F
Channel bracket, wall mount
7ML1830-1BL
Extended channel bracket, wall mount
7ML1830-1BM
DN 80, PN 10/16, Type A, flat faced
DN 100, PN 10/16, Type A, flat faced
DN 150, PN 10/16, Type A, flat faced
G
J
L
Channel bracket, floor mount
7ML1830-1BN
Extended channel bracket, floor mount
7ML1830-1BP
M
P
R
Bridge channel bracket, floor mount
(see Mounting Brackets on page 4/187 for
more information)
7ML1830-1BQ
1" NPT locknut, plastic
7ML1830-1DS
1" BSPT locknut, plastic
7ML1830-1DR
JIS10K3B Style
JIS10K4B Style
JIS10K6B Style
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5 or EN 1092-1, or JIS B 2220 standard.)
Approvals
ATEX 2GD Ex mb IIC T4 Gb, Ex tb IIIC T135 °C Db;¢
IECEx SIR 13.0009X Ex mb IIC T4 Gb, Ex tb IIIC
T135 °C Db; FM Class I, Div. 2, Groups A,B,C,D;
Class II, Div. 1, Groups E,F,G; Class III
CSA Class I, Div. 1, Groups A,B,C,D, Class II,
¢
Div. 1, Groups E,F,G, Class III 3)
1)
Not available with flanged versions
2)
Available with flanged versions only
3)
Valid with mounting thread and facing options 0 ... 2 only
3
4
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
4/180
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic transducers
EchoMax XPS
Selection and Ordering data
Article No.
Selection and Ordering data
EchoMax XPS-15 ultrasonic transducer
High-frequency ultrasonic transducer designed
for a wide variety of liquid and solid applications,
for use with approved controllers. Includes integral
temperature sensor.
Measuring range: min. 0.3 m, max. 15 m
7ML1118-
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
7777 0
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Measuring point number/ identification
(max. 27 characters) specify in plain text
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Mounting thread and facing
1" NPT [(Taper), ANSI/ASME B1.20.1]
1" NPT [(Taper), ANSI/ASME B1.20.1]
with foam facing1)
1" NPT [(Taper), ANSI/ASME B1.20.1]
with PTFE facing2)
Order code
¢ 0
1
2
R 1" [(BSPT), EN 10226]
R 1" [(BSPT), EN 10226] with foam facing1)
R 1" [(BSPT), EN 10226] with PTFE facing2)
¢ 3
4
5
Cable length
5 m (16.40 ft)
10 m (32.81 ft)
30 m (98.43 ft)
¢
¢
¢
Operating Instructions
Article No.
Quick Start guide, multi-language
A5E32282889
Applications Guidelines, multi-language
Note: The Applications Guidelines should be
ordered as a separate line item on the order.
7ML1998-5HV61
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
Accessories
Tag, stainless steel with hole, 12 x 45 mm
(0.47 x 1.77 inch), one text line for fastening on
sensors
7ML1930-1BJ
Submergence shield kit
7ML1830-1BJ
Universal box bracket, mounting kit
7ML1830-1BK
Channel bracket, wall mount
7ML1830-1BL
A
Extended channel bracket, wall mount
7ML1830-1BM
6" ASME, 150 lb, flat faced
8" ASME, 150 lb, flat faced
D
E
Channel bracket, floor mount
7ML1830-1BN
DN 150, PN 10/16, Type A, flat faced
DN 200, PN 10, Type A, flat faced
J
K
Extended channel bracket, floor mount
7ML1830-1BP
7ML1830-1BQ
JIS10K 6B
JIS10K 8B
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5 or EN 1092-1, or JIS B 2220 standard.)
N
P
Bridge channel bracket, floor mount
(see Mounting Brackets on page 4/187 for
more information)
1" NPT locknut, plastic
7ML1830-1DS
1" BSPT locknut, plastic
7ML1830-1DR
Easy Aimer 2, with ¾" x 1" NPT PVC coupling
7ML1830-1AQ
Easy Aimer 2, aluminum with M20 adapter and
1" and 1½" BSPT aluminum couplings
7ML1830-1AX
Easy Aimer 304 with stainless steel coupling
7ML1830-1AU
Easy Aimer 304, with M20 adapter and 1" and 1½"
BSPT 304 stainless steel couplings
7ML1830-1GN
F
K
50 m (164.04 ft)
100 m (328.08 ft)
Mounting flange
None
¢
Approvals
ATEX 2GD Ex mb IIC T4 Gb, Ex tb IIIC T135 °C Db; ¢
IECEx SIR 13.0009X Ex mb IIC T4 Gb, Ex tb IIIC
T135 °C Db; FM Class I, Div. 2, Groups A,B,C,D;
Class II, Div. 1, Groups E,F,G; Class III
CSA Class I, Div. 1 Groups A,B,C,D, Class II,
¢
Div. 1, Groups E,F,G, Class III 3)
1)
Not available with flanged versions
2)
Available with flanged versions only
3)
Available with mounting options 0 ... 2 only
B
C
E
3
4
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Siemens FI 01 · 2015
4/181
4
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic transducers
EchoMax XPS
Selection and Ordering data
Article No.
Selection and Ordering data
Article No.
EchoMax XPS-15F ultrasonic transducer
High-frequency ultrasonic transducer designed
for a wide variety of liquid and solid applications,
for use with approved controllers. Includes integral
temperature sensor.
Measuring range: min. 0.3 m, max. 15 m
7ML1171-
EchoMax XPS-30 ultrasonic transducer
High-frequency ultrasonic transducer designed
for a wide variety of liquid and solid applications,
for use with approved controllers. Includes integral
temperature sensor.
1½" universal thread compatible with 1½" NPT and
R 1½" [(BSPT), EN 10226]
Measuring range: min. 0.6 m (1.97 ft), max. 30 m
(98.43 ft)
7ML1123-
777 7 0
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Mounting thread and facing
1" NPT [(Taper), ANSI/ASME B1.20.1]
4
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
1
Cable length
5 m (16.40 ft)
10 m (32.81 ft)
30 m (98.43 ft)
B
C
D
50 m (164.04 ft)
100 m (328.08 ft)
E
F
Mounting flange, flush mount
None
6" ASME, 150 lb, flat faced
8" ASME, 150 lb, flat faced
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5, or EN 1092-1, or JIS B 2220 standard.)
Mounting thread and facing
1½" universal thread
1½" universal thread, foam facing1)
1½" universal thread, PTFE facing2)
A
B
C
Approvals
FM Class I, Div. 1, Groups A, B, C, and D, Class II
Div. 1, Groups E, F, and G, Class III
Selection and Ordering data
1
Order code
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring point number/ identification
(max. 27 characters) specify in plain text
Y15
Operating Instructions
Article No.
English
A5E32725813
Applications Guidelines, multi-language
Note: The Applications Guidelines should be
ordered as a separate line item on the order.
7ML1998-5HV61
0
1
2
Cable length
5 m (16.40 ft)
10 m (32.81 ft)
30 m (98.43 ft)
B
C
E
50 m (164.04 ft)
100 m (328.08 ft)
F
K
Mounting flange
None
A
6" ASME, 150 lb, flat faced
8" ASME, 150 lb, flat faced
D
E
DN 150, PN 10/16, Type A, flat faced
DN 200, PN 10, Type A, flat faced
J
K
JIS10K 6B
JIS10K 8B
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5 or EN 1092-1, or JIS B 2220 standard.)
N
P
Approvals
ATEX 2G 1D Ex mb IIC T4 Gb, Ex ta IIIC T135 °C
Da; IECEx SIR 13.0009X Ex mb IIC T4 Gb,
Ex ta IIIC T135 °C Da
1)
Not available with flanged versions
2)
Available with flanged versions only
Selection and Ordering data
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
5
Order code
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
Accessories
Tag, stainless steel with hole, 12 x 45 mm
(0.47 x 1.77 inch), one text line for fastening on
sensors
7ML1930-1BJ
Submergence shield kit
7ML1830-1BJ
Universal box bracket, mounting kit
7777 0
7ML1830-1BK
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
measuring-point number/identification
(max. 27 characters) specify in plain text
Y15
Operating Instructions
Article No.
Quick Start guide, multi-language
A5E32282889
Applications Guidelines, multi-language
Note: The Applications Guidelines should be
ordered as a separate line item on the order.
7ML1998-5HV61
Channel bracket, wall mount
7ML1830-1BL
Extended channel bracket, wall mount
7ML1830-1BM
Channel bracket, floor mount
7ML1830-1BN
Extended channel bracket, floor mount
7ML1830-1BP
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
Bridge channel bracket, floor mount
(see Mounting Brackets on page 4/187 for
more information)
7ML1830-1BQ
Accessories
7ML1930-1BJ
1" NPT locknut, plastic
7ML1830-1DS
Tag, stainless steel with hole, 12 x 45 mm
(0.47 x 1.77 inch), one text line for fastening on
sensors
Easy Aimer 2, with ¾" x 1" NPT PVC coupling
7ML1830-1AQ
1½" BSPT locknut, plastic
7ML1830-1DP
Easy Aimer 304 with stainless steel coupling
7ML1830-1AU
Easy Aimer 2, 1½" NPT galvanized coupling
7ML1830-1AN
Easy Aimer 304, NPT with 1½" coupling
7ML1830-1AT
Easy Aimer 2, aluminum with M20 adapter and
1" and 1½" BSPT aluminum couplings
7ML1830-1AX
Easy Aimer 304, with M20 adapter and 1" and
1½" BSPT 304 stainless steel couplings
7ML1830-1GN
4/182
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic transducers
EchoMax XPS
Selection and Ordering data
EchoMax XPS-30C ultrasonic transducer
High-frequency ultrasonic transducer designed
for a wide variety of liquid and solid applications,
for use with approved controllers. Includes integral
temperature sensor.
1½" universal thread compatible with 1½" NPT and
R 1½" [(BSPT), EN 10226]
Measuring range: min. 0.6 m (1.97 ft), max. 30 m
(98.43 ft)
Article No.
7ML1155777 7 1
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Mounting thread and facing
1½" universal thread
1½" universal thread, foam facing1)
1½" universal thread, PTFE facing2)
0
1
2
Stainless steel tag [69 mm x 50 mm
(2.71 x 1.97 inch)]: Measuring-point number /
identification (max. 27 characters) specify in plain
text
Y15
Operating Instructions
Article No.
Quick Start guide, multi-language
A5E32282889
Applications Guidelines, multi-language
Note: The Applications Guidelines should be
ordered as a separate line item on the order.
7ML1998-5HV61
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
Cable length
5 m (16.40 ft)
10 m (32.81 ft)
30 m (98.43 ft)
B
C
E
50 m (164.04 ft)
100 m (328.08 ft)
F
K
Accessories
Mounting flange
None
A
6" ASME, 150 lb, flat faced
8" ASME, 150 lb, flat faced
D
E
DN 150, PN 10/16, Type A, flat faced
DN 200, PN 10, Type A, flat faced
J
K
JIS10K 6B
JIS10K 8B
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5 or EN 1092-1, or JIS B 2220 standard.)
N
P
Approvals
CSA, Class I, Div. 2, Groups A,B,C,D; Class II,
Div. 1, Groups E,F, G; Class III
Order code
Selection and Ordering data
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
Easy Aimer II NPT 1.5" Galvanized
7ML1830-1AN
Easy Aimer 304, NPT with 1.5" coupling
7ML1830-1AT
1½" BSPT locknut, plastic
7ML1830-1DP
1)
Not available with flanged version
2)
Available for flanged versions only
4
Siemens FI 01 · 2015
4/183
4
© Siemens AG 2014
Level Measurement
Continuous level measurement – Ultrasonic transducers
EchoMax XPS
■ Dimensional drawings
■ Schematics
Standard
Direct connection
J
Submergence shield
B
Black
White
F
Shield
A
Coaxial connection
Radiating face
White
Bonded flange
Shield
E
B
4
3 terminal direct*
C
Black
Shield
XPS ultrasonic transducer, dimensions in mm (inch)
White
Version
Dimension
XPS-10
XPS-15
XPS-30
A
88 mm
(3.464 inch)
121 mm
(4.764 inch)
175 mm
(6.890 inch)
B
122 mm
(4.803 inch)
132 mm
(5.197 inch)
198 mm
(7.795 inch)
3 terminal extension*
Black
White
C
According to ASME, DIN and JIS
E
124 mm
(4.882 inch)
158 mm
(6.220 inch)
n/a
F
152 mm
(5.984 inch)
198 mm
(7.795 inch)
n/a
J
28 mm
(1.1 inch)
28 mm
(1.1 inch)
28 mm
(1.1 inch)
Shield
* For SITRANS LUT400, MultiRanger 100/200, HydroRanger 200
Mounting
Make particularly sure that the radiating face of the transducer is
protected from damage. Mount the transducer so that it is above the
maximum material level by at least the blanking value. On liquid
applications, the transducer must be mounted so that the axis of
transmission is perpendicular to the liquid surface. On solids applications,
a Milltronics Easy Aimer should be used to facilitate aiming the
transducer. Consider the optional temperature sensor when mounting
the transducer.
Interconnection
Do not route cable openly or near high voltage or current runs, contactors
and SCR control drives. For optimum isolation against electrical noise,
run cable separately in a grounded metal conduit. Seal all thread
connections to prevent ingress of moisture.
XPS ultrasonic transducer connections
4/184
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Continuous level measurement – Accessories for ultrasonic
EA aiming devices
■ Application
■ Application
EA 304 aiming device
EA 2 aiming device
The Easy Aimer 304 flange is a stainless steel aiming device for
alignment of Siemens ultrasonic transducers used for level measurement of bulk solids.
The Easy Aimer 2 flange is a cast aluminum aiming device for
alignment of Siemens ultrasonic transducers.
The sensor must be mounted aimed towards the low level draw
point in the silo. The sensor can be rotated through 360° and
angled at 0 to 27° off vertical. It must be mounted using an
access plate with welded studs or a flange in order to isolate
the mounting holes from the pressurized environment. When
installed properly, the EA 304 aiming device is capable of withstanding pressures up to 0.5 bar (Europe) or 15 psi (North America). It can even be used in corrosive and aggressive environments.
■ Dimensional drawings
The flange has graduated adjustments and an adjustable insertion length. When used for applications with bulk solids, the sensor is mounted so that it is aimed towards the lower level draw
point in the silo. The sensor can be rotated through 360° and
angled at 0 to 20° off vertical. It must be mounted using an
access plate with welded studs or a flange in order to isolate
the mounting holes from the pressurized environment. When
installed properly, the EA 2 aiming device is capable of withstanding pressures up to 0.5 bar (Europe) or 15 psi (North America). It can even be used in corrosive and aggressive environments.
4
■ Dimensional drawings
¾” NPT or BSP
conduit x 300 (12) long
Conduit gland
10 (0.38)
170 (6.7)
Locknut
1" NPT or BSP
Mounting block
(lower socket)
Customer gasket
(as required)
135 (5.3)
nominal
Angle block
Clamping plate
(upper socket)
Sighting block
76 (3)
16
nominal (0.63)
Customer
mounting plate
(as required)
Ø127 (5)
typical
Mounting
block
Customer
gasket
(as required)
127 (5)
Ø typical
Coupling/adapter
Coupling/
Adapter
Siemens
Milltronics
transducer
(typical)
Customer
mounting plate
(as required)
Siemens Milltronics
Transducer (typical)
max 20°
Mounting hole - 3 places
to suit M8 or ⅜ inch,
120° apart on 157 mm
(6.2 inch) bolt center diameter
Mounting hole 3 places 11 (7/16)
on 157 (6.2) bolt
center diameter
LL
TR
ONI
CS
Ground screw
MI
máx. 27°
Angle block binding
screw and clamp
Sighting block binding
screw and clamp
Clamping screw
(3 places)
A
E
SY
A IM
ER
II
Ground screw
178 (7)
EA 304 aiming device, dimensions in mm (inch)
178
(7.0)
EA 2 aiming device, dimensions in mm (inch)
Siemens FI 01 · 2015
4/185
© Siemens AG 2014
Level Measurement
Continuous level measurement – Accessories for ultrasonic
EA aiming devices
Selection and Ordering data
Article No.
Easy aimer
Used on solids applications to aim transducers for
optimal performance. Available in a 304 stainless
steel model, or a cast aluminum model.
4
Easy Aimer 2, aluminum with M20 adapter and 1"
and 1½" BSPT aluminum couplings
7ML1830-1AX
Easy Aimer 304, with M20 adapter and 1" and
1½" BSPT 304 stainless steel couplings
7ML1830-1GN
Easy Aimer 2, aluminum, BSPT conduit
Easy Aimer 2, aluminum, NPT with 1½" galvanized
coupling1)
7ML1830-1AL
Easy Aimer 2, aluminum, NPT with 1" galvanized
coupling
Easy Aimer 2, aluminum, NPT with ¾" x 1"
PVC coupling
7ML1830-1AP
Easy Aimer 304, BSPT conduit
Easy Aimer 304, NPT with 1½" coupling1)
7ML1830-1AS
Easy Aimer 304, NPT with 1" coupling
7ML1830-1AU
Operating Instructions
Easy Aimer 2 and 304 Operating Instructions,
Multi-language
Note: The Operating Instructions should be
ordered as a separate line item on the order.
This device is shipped with the Siemens Milltronics
manual DVD containing the Quick Start and Operating Instructions library.
1)
For use with XPS-30 transducers only
4/186
Siemens FI 01 · 2015
7ML1830-1AN
7ML1830-1AQ
7ML1830-1AT
7ML1998-5HG62
© Siemens AG 2014
Level Measurement
Continuous level measurement – Accessories for ultrasonic
FMS mounting brackets
■ Application
■ Integration
Siemens mounting brackets permit simple, fast installation of
ultrasonic transducers. These rugged, high quality mounting
brackets are constructed of 304 (1.4301) stainless steel and are
suitable for use indoors and outdoors. They adjust to fit almost
any application, saving you the time and expense of building
custom brackets. Each kit includes all mounting parts.
FMS-200
Universal box bracket
FMS-200
universal box bracket system
Mounting of units with 1 inch or 2 inch threaded connection.
Distance from sensor to wall or beam: 20 ... 31 cm (8 ... 12 inch).
FMS-210
Channel bracket,
wall mount
The unique box design also acts as a sun shield for transducers
with 1 inch threaded connections.
FMS-210
wall mounting set
4
Mounting of transducers with 1 inch threaded connection.
Distance from transducer to wall or beam: 12 ... 48 cm
(5 ... 19 inch).
FMS-220
Extended channel bracket,
wall mount
FMS-220
extended wall mounting set
Mounting of transducers with 1 inch threaded connection.
Distance from transducer to wall or beam: 32 ... 98 cm
(13 ... 39 inch).
FMS-310
floor mounting set
Mounting of transducers with 1 inch threaded connection.
Distance from transducer to floor: 20 ... 48 cm (8 ... 19 inch).
Distance from mounting support: 5 ... 57 cm (2 ... 22 inch).
FMS-320
extended floor mounting set
FMS-310
Channel bracket,
floor mount
Mounting of transducers with 1 inch threaded connection.
Distance from transducer to floor: 20 ... 48 cm (8 ... 19 inch).
Distance from mounting support: 41 ... 108 cm (16 ... 43 inch).
FMS-350
floor mounting set, bridge
Mounting of transducers with 1 inch threaded connection.
Distance from transducer to floor: 20 ... 48 cm (8 ... 19 inch),
anywhere along the complete width of the bridge
[166 cm (65 inch)].
FMS-320
Extended channel bracket,
floor mount
This kit is particularly suitable for measurements on open channels (OCM) by providing a very stable mount for the transducer
above a flume or weir.
FMS-350
Bridge channel bracket,
floor mount
FMS mounting brackets
Siemens FI 01 · 2015
4/187
© Siemens AG 2014
Level Measurement
Continuous level measurement – Accessories for ultrasonic
FMS mounting brackets
Selection and Ordering data
Article No.
Mounting brackets for XPS-10 sensors
FMS-200 universal box bracket set
7ML1830-1BK
FMS-210 wall mounting set
7ML1830-1BL
FMS-220 extended wall mounting set
7ML1830-1BM
FMS-310 floor mounting set
7ML1830-1BN
FMS-320 extended floor mounting set
7ML1830-1BP
FMS-350 floor mounting set, bridge
7ML1830-1BQ
Additional Operating Instructions
4
FMS-200
7ML1998-5BK61
FMS-210
7ML1998-5BL61
FMS-220
7ML1998-5BM61
FMS-310
7ML1998-5BN61
FMS-320
7ML1998-5BP61
FMS-350
Note: The Operating Instructions should be
ordered as a separate line item on the order.
7ML1998-5BQ61
4/188
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Continuous level measurement – Accessories for ultrasonic
TS-3 temperature sensor
■ Overview
■ Design
Clearance
Conduit (supplied by others)
Coupling (supplied by others)
TS-3
Plate or wall
4
Locknut (supplied by others)
The TS-3 temperature sensor provides an input signal for
temperature compensation of specific Siemens ultrasonic level
controllers.
Note: Clearance hole/
locknut Installation
method is not suitable
for pressure applications.
■ Benefits
• Chemically resistant ETFE enclosure
• Fast response time
• Approved for use in potentially explosive atmospheres
Tapped
■ Application
Temperature compensation is essential in applications where
temperature variations of the sound medium are expected.
By installing the temperature sensor close to the sound path of
the associated ultrasonic transducer, a signal representative of
the sound medium’s ambient temperature is obtained. The temperature sensor should not be mounted in direct sunlight.
The TS-3 is used in conjunction with ultrasonic transducers that
do not have an integral temperature sensor. It is also recommended in cases where the integral temperature sensor of the
transducer cannot be used.
Flange or wall
The following conditions are typical for use of the TS-3 sensor:
where a fast reaction to temperature variations is required, where
a flanged ultrasonic transducer is used, or where high temperatures are encountered.
The TS-3 is not compatible with devices using the TS-2 or LTS-1
temperature sensors. Refer to the associated controller manual
for more details.
• Key Applications: For use in applications where temperature
sensor measurement from transducer does not accurately
represent vessel temperature. Used for applications requiring
quick temperature response (open channel monitoring).
TS-3 temperature sensor
Siemens FI 01 · 2015
4/189
© Siemens AG 2014
Level Measurement
Continuous level measurement – Accessories for ultrasonic
TS-3 temperature sensor
■ Technical specifications
Mode of operation
Measuring principle
Temperature sensor
Input
Measuring range
-40 ... +100 °C (-40 ... +212 °F)
Output
Response time
• Forced circulation
(temperature variation: 63 %)
• Flange, forced circulation
• Natural convection
4
7ML181377B 7
Cable length
90 s
150 s
Mounted indoors/outdoors, but not
exposed to direct sunlight
Max. 4 bar (60 psi/400 kPa)
• Pressure
Article No.
TS-3 temperature sensor
TS-3 provides an input signal for temperature
compensation of specific Siemens ultrasonic level
controllers.
Compensation is essential in applications where
variation in temperature of the sound medium is
expected.
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
55 s
Rated operating conditions
• Installation instructions
Selection and Ordering data
Design
1 m (3.28 ft)
1
5 m (16.40 ft)
2
10 m (32.81 ft)
3
30 m (98.43 ft)
4
50 m (164.04 ft)
5
Material (enclosure)
ETFE1)
70 m (229.66 ft)
6
Cable connection
2-core, 0.5 mm² (20 AWG), shielded,
silicone sheath
90 m (295.28 ft)
7
¾" NPT [(Taper), ANSI/ASME
B1.20.1]
Process connection
¾" NPT [(Taper), ANSI/ASME B1.20.1]
R ¾" [(BSPT), EN 10226]
Process connection
R ¾" [(BSPT), EN 10226], totally
encapsulated
CE, IEC Ex, FM, CSA, ATEX
Certificates and approvals
1)
ETFE is a fluoropolymer inert to most chemicals. For exposure to specific
environments, check the chemical compatibility charts before installing the
TS-3 in your application.
■ Dimensional drawings
Approvals
CSA, FM
CE, ATEX, IEC Ex
A
B
3
4
Operating Instructions
English
A5E32337739
German
A5E34990011
Note: The Operating Instructions should be
ordered as a separate line item on the order.
SITRANS LUT400
only
S
BWH
L H L
KT D
Accessories
Refer to associated
manual for terminal
block detail
OR
BW
L H
KT
Connect direct or
via customer junction box
Cable
15
20
(0.6) (0.8)
¾" NPT or
BSP
(2 places)
15
(0.6)
136
(5.4)
76
(3.0)
Hex hub
27 (1 1/16)
TS-3 temperature sensor, dimensions in mm (inch)
4/190
Siemens FI 01 · 2015
This device is shipped with the Siemens Milltronics
manual DVD containing ATEX Quick Starts and
Operating Instructions.
¾" NPT locknut, aluminum
7ML1930-1BE
Tag, stainless steel with hole, 12 x 45 mm
(0.47 x 1.77 inch) for fastening on sensors
7ML1930-1BJ
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
Radar transmitters
■ Overview
■ Mode of operation
Radar measurement technology is non-contacting and low
maintenance. Because microwaves require no carrier medium,
they are virtually unaffected by the process atmosphere (vapor,
pressure, dust, or temperature extremes). Siemens offers a variety of models to meet the specific needs of your application.
Principle of Operation
SITRANS Probe LR is a 2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage
vessels with nominal pressure and temperature, to a range of
20 m (66 ft).
Unlike ultrasonic measurement, radar technology does not
require a carrier medium and travels at the speed of light
(300 000 000 m/s). Most industrial radar devices operate from
6 to 26 GHz.
SITRANS LR200 is a 2-wire, 6 GHz pulse radar level transmitter
for continuous monitoring of liquids and slurries in process vessels including high temperature, pressure, agitation,
and turbulence to a range of 20 m (65 ft).
Siemens offers pulse radar transmitters (SITRANS Probe LR,
SITRANS LR200, SITRANS LR250, SITRANS LR260) and FMCW
(Frequency Modulated Continuous Wave) radar transmitters
(SITRANS LR460, SITRANS LR560).
SITRANS LR250 is a 2-wire, 25 GHz pulse radar level transmitter
for continuous monitoring of liquids and slurries in storage and
process vessels including high temperature and pressure,
corrosive or aggressive materials, to a range of 20 m (66 ft).
Ideal for small vessels and low dielectric media.
Pulse radar emits a microwave pulse from the antenna at a fixed
repetition rate that reflects off the interface between the two
materials with different dielectric constants (the atmosphere and
the material being monitored). The echo is detected by a
receiver and the transmit time is used to calculate level.
SITRANS LR260 is a 2-wire, 25 GHz pulse radar level transmitter
for continuous monitoring of solids in silos to a range of 30 m
(98.4 ft). Ideal for applications with extreme dust and high temperatures to 200 °C (392 °F) and liquids in vessels.
Reflected echoes are digitally converted to an echo profile.
The profile is analyzed to determine the distance from the material surface to the reference point on the instrument.
SITRANS LR460 is a 4-wire, 24 GHz FMCW radar level transmitter with extremely high signal to noise ratio and advanced signal
processing for continuous monitoring of solids up to 100 m
(328 ft). It is ideal for measurement in extreme dust.
Radar measurement technology measures the time of flight from
the transmitted signal to the return signal. From this time,
distance measurement and level are determined.
FMCW (Frequency Modulated Continuous Wave) radar devices
send microwaves to the surface of the material. The wave
frequency is modulated continuously. At the same time,
the receiver is also receiving continuously and the difference in
frequency between the transmitter and the receiver is directly
proportional to the distance to the material.
SITRANS LR560 2-wire, 78 GHz FMCW radar level transmitter for
continuous monitoring of solids in silos to a range of 100 m
(329 ft).
Auto False-Echo Suppression
Level (db)
SITRANS LR instruments offer the unique advantage of Process
Intelligence signal processing technology. This in-depth knowledge and experience is built into the software’s advanced algorithms to provide intelligent processing of echo profiles. The result is repeatable, fast and reliable measurement.
Echo from
agitator
A special feature of SITRANS radar devices is Auto False-Echo
Suppression, an echo processing technique that automatically
detects and suppresses false echoes from vessel obstructions.
You can implement this feature using two parameters on the
local interface or SIMATIC PDM communicating over HART or
PROFIBUS PA.
Surface echo
Local display interface – graphically displays echo
profiles and diagnostic information
(available with LR200, LR250, LR260 and LR560)
Quick to configure – Quick Start Wizard via SIMATIC
PDM guides you during setup
(available with LR200, LR250, LR260, LR460, LR560)
Distance
Radar operation in a reactor vessel
Siemens FI 01 · 2015
4/191
4
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
Radar transmitters
■ Technical specifications
Radar Selection Guide
4
Criteria
SITRANS
Probe LR
SITRANS
LR200
Typical industries
Chemicals, petrochemicals, water/
waste-water, drilling
mud
Typical applications
SITRANS
LR260
SITRANS
LR460
SITRANS
LR560
Chemicals, petroChemicals, petrochemicals, aluminum, chemicals, and oil
wastewater
and gas, mining,
marine, food and
beverage, and pharmaceutical
Cement, power
generation, petrochemical, food
processing, mineral
processing, mining
Cement, power
generation, food
processing, mineral
processing, mining
Cement, power
generation, food
processing, mineral
processing, mining
Liquids, storage
vessels, wet wells,
and drilling mud
tanks
Liquids, process
vessels with agitators, build-up, and
high temperatures
Liquids, storage and
process vessels with
agitators, vaporous
liquids, high temperatures, low dielectric
media, and crude oil
produced water
Cement, plastics,
grain, flour, coal,
liquids < 20 m, and
low dielectric liquids
< 30 m
Cement, fly ash,
grain, coal, flour,
plastics
Cement, fly ash,
grain, coal, flour,
plastics
Range
0.3 ... 20 m
(1 ... 65 ft)
0.4 ... 20 m
(1.3 ... 65 ft)
50 mm (2 inch)
from end of horn
to 20 m (65 ft),
horn dependent
30 m (98.4 ft)
100 m (328 ft)
40 m (131 ft)
100 m (328 ft)
Frequency
5.8 GHz
(North America
6.3 GHz)
5.8 GHz
(North America
6.3 GHz)
K-band
(25.0 GHz)
K-band
(25.0 GHz)
24 ... 25 GHz FMCW 78 ... 79 GHz
Performance
accuracy
0.1 % of range or
10 mm (0.4 inch)
0.1 % of range or
10 mm (0.4 inch)
Temperature
Ambient:
-40 ... +80 °C
(-40 ... +176 °F)
Ambient:
-40 ... +80 °C
(-40 ... +176 °F)
Process:
-40 ... +80 °C
(-40 ... +176 °F
Output/communica- • 4 ... 20 mA/HART
tions/remote configu- • SIMATIC PDM
ration and
diagnostics
SITRANS
LR250
 5 mm (0.02 inch)
25 mm (1 inch) from 0.25 %
minimum detectable
distance to 300 mm
(11.8 inch)
Remainder of range
= 10 mm (0.39 inch)
or 0.1 % of span
(whichever is greater)
0.25 %
Ambient:
-40 ... +80 °C
(-40 ... +176 °F)
Ambient:
-40 ... +80 °C
(-40 ... +176 °F)
Ambient:
+65 °C (+149 °F)
Ambient:
-40 ... +80 °C
(-40 ... +176 °F)
Process:
-40 ... +200 °C
(-40 ... +392 °F),
dependent on
antenna type
Process:
-40 ... +200 °C
(-40 ... +392 °F)
dependent on
antenna type
Process:
-40 ... +200 °C
(-40 ... +392 °F)
dependent on
antenna type
Process:
+200 °C
(+392 °F)
Process:
-40 ... +100 °C
(-40 ... 212 °F)
•
•
•
•
•
4 ... 20 mA/HART
PROFIBUS PA
SIMATIC PDM
AMS
SITRANS
DTM/FDT for
PACTware,
Fieldcare,
etc.
• 4 ... 20 mA/HART
• PROFIBUS PA
• FOUNDATION
Fieldbus
• SIMATIC PDM
• AMS
• SITRANS
DTM/FDT for
PACTware,
Fieldcare,
etc.
• 4 ... 20 mA/HART
• PROFIBUS PA
• SIMATIC PDM
• 4 ... 20 mA/HART
• PROFIBUS PA
• SIMATIC PDM
• 4 ... 20 mA/HART
• PROFIBUS PA
• FOUNDATION
Fieldbus
• SIMATIC PDM
• AMS
• SITRANS
DTM/FDT for
PACTware,
Fieldcare,
etc.
Optional:
+200 °C (+392 °F)
Power
• 24 V DC nominal
• Loop powered
• 24 V DC nominal
• Loop powered
• 24 V DC nominal
• Loop powered
• 24 V DC nominal
• Loop powered
• 100 ... 230 V AC,
±15 %, 50/60 Hz,
6W
• 24 V DC,
+25/-20 %, 6 W
• 24 V DC nominal
• Loop powered
Approvals
CE, RCM, Lloyds
Register of Shipping,
ABS,
FCC, Industry
Canada, R&TTE
CE, RCM, Lloyds
Register of Shipping,
ABS, FCC, Industry
Canada, R&TTE
CE, RCM, Lloyds
Register of Shipping,
ABS, BV, FCC, Industry Canada, R&TTE
CE, RCM, FCC,
Industry Canada,
R&TTE
CE, RCM, FCC,
Industry Canada,
R&TTE
CE, RCM, FCC,
Industry
Canada, R&TTE
ATEX, CSA, FM,
INMETRO, GOST-R,
IECEx, ANZEx, TIIS,
NEPSI
ATEX, CSA, FM,
INMETRO, GOST-R,
IECEx, TIIS, NEPSI
ATEX, CSA, FM,
INMETRO, GOST,
IECEx
ATEX, CSA, FM,
INMETRO, IECEx,
GOST
ATEX, CSA, FM,
INMETRO, IECEx,
NEPSI, GOST
ATEX, CSA, FM,
INMETRO, GOST-R,
IECEx, ANZEx, TIIS
4/192
Siemens FI 01 · 2015
Functional safety
SIL-2, EHEDG, 3-A,
USP Class VI
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
Radar transmitters
■ Application
Radar Application Questionnaire
Customer information
Contact:
Prepared By:
Company:
Date:
Notes on the Application:
Address:
City:
Zip/Postal Code:
Country:
Phone: (
)
(
)
Fax:
E-mail:
4
Sketch attached
Vessel Information
SITRANS
LR 400
Storage
Solids
Process
Storage
Liquids
Reactor
Area safety classification: (specify code required)
Height:
m/ft Diameter:
Top:
m/ft
Atmosphere: (indicate all that apply)
Filling method:
Pressure:
Flat
Foam
Steam
Normal:
Parabolic
Dust
Deposit (build-up)
Maximum (relief):
Conical
Vapor
Mounting connection (specify type)
Critical Information
Distance to sidewall:
cm/inch
Mounting connection maximum temperature:
C/ F
Max. temperature at electronics:
C/ F
Stilling well or Still Pipe mounting:
Yes
No
Nozzle Length:
cm/inch
Nozzle Diameter:
cm/inch
Stilling well diameter:
cm/inch
Material
Liquid
Material being measured:
C/ F Max:
Material temperature: Norm:
Material surface:
Flat
Installation
Power available:
Tu
Agitated
Solid
Liquified gas
C/ F
Vortex
Dielectric constant:
r<
r>
Communications:
HART /4 ... 20 mA
PROFIBUS PA
FOUNDATION Fieldbus
None
Products recommended:
© Siemens Milltronics Process Instruments Inc.
www.siemens.com/processautomation
Form# 2-763R7
Siemens FI 01 · 2015
4/193
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS Probe LR
■ Overview
■ Configuration
Installation
Min. 300 mm (1 ft) for every
3 m (10 ft) of vessel wall.
Beam
angle 28°
4
SITRANS Probe LR is a 2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage
vessels with nominal pressure and temperature, to a range of
20 m (66 ft).
Mounting unit on vessel
■ Benefits
• Uni-Construction polypropylene rod antenna standard
• Easy installation and simple start-up
• Programming using infrared Intrinsically Safe handheld
programmer, SIMATIC PDM or HART handheld communicator
• Communication using HART
• Process Intelligence signal processing
• Extremely high signal-to-noise ratio
• Auto False-Echo Suppression of false echoes
Conical
Mounting on a manhole cover
Flat
Parabolic
Mounting on a nozzle
■ Application
Probe LR is designed for safe and simple programming using
the Intrinsically Safe handheld programmer without having to
open the instrument’s lid. It has a standard Uni-Construction
polypropylene rod antenna that offers excellent chemical resistance and is hermetically sealed. The Uni-Construction antenna
includes an internal, integrated shield that eliminates vessel nozzle interference.
SITRANS Probe LR incorporates Process Intelligence signal
processing. The Probe LR also has a high signal-to-noise ratio
leading to improved reliability.
Start-up is easy with as few as two parameters for basic operation. Programming is simple using SIMATIC PDM, HART handheld communicator or the Intrinsically Safe handheld programmer.
• Key Applications: chemical storage, wastewater wet well,
and drilling mud
4/194
Siemens FI 01 · 2015
Min.
10 (0.4)
The Probe LR is ideal for applications with chemical vapors,
temperature gradients, vacuum or pressure, such as simple
chemical storage or water treatment vessels. SITRANS Probe LR
has a range of 0.3 to 20 m (1 to 65 ft).
Min. 100 (4)
SITRANS Probe LR
shield length 100 (4) or
250 (10) standard
lengths
SITRANS Probe LR installation, dimensions in mm (inch)
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS Probe LR
■ Technical specifications
Mode of operation
Power supply
Measuring principle
Pulse radar level measurement
Frequency
5.8 GHz (North America 6.3 GHz)
Measuring range
0.3 ... 20 m (1.0 ... 65 ft)
Output
Analog output
4 ... 20 mA
Accuracy
± 0.02 mA
Span
Proportional or inversely proportional
Communications
HART
Performance (reference conditions)
Accuracy
± the greater of 0.1 % of range or
10 mm (0.4 inch)
Influence of ambient temperature
0.003 %/K
Repeatability
± 5 mm (2 inch)
Fail-safe
mA signal programmable as high,
low or hold (LOE)
Certificates and approvals
General
CSAUS/C, CE, FM, RCM
Marine
• Lloyd's Register of Shipping
• ABS Type Approval
Radio
FCC, Industry Canada and European
(R&TTE), RCM
Hazardous
• Intrinsically Safe (Brazil)
• Intrinsically Safe (Canada)
•
•
•
•
Intrinsically Safe (Europe)
Intrinsically Safe (International)
Intrinsically Safe (Russia)
Intrinsically Safe (USA)
INMETRO Ex ia IIC T4 Ga
CSA Class I, Div.1, Groups A,B,C,D;
Class II, Div. 1, Group G; Class III
ATEX II 1G EEx ia IIC T4
IECEx Ex ia IIC T4
GOST-R Ex ia
FM Class I, Div.1, Groups A,B,C,D;
Class II, Div. 1, Groups E,F, G;
Class III
Programming
Rated operating conditions
Installation conditions
• Location
• Nominal 24 V DC with max. 550 ,
maximum 30 V DC
• 4 ... 20 mA
Indoor/outdoor
Handheld programmer
HART communicator 375
PC
SIMATIC PDM
• Ambient temperature
-40 ... +80 °C (-40 ... +176 °F)
• Installation category
I
Intrinsically safe Siemens handheld Infrared receiver
programmer (optional)
• Approvals (handheld programmer) ATEX II 1G EEx ia IIC T4
CSA and FM Class I, Div.1,
Groups A,B,C,D, T6 at max. ambient
• Pollution degree
4
Display (local)
Ambient conditions (enclosure)
Medium conditions
Dielectric constant r
r > 1.6 (for r < 3, use stillpipe)
Vessel temperature
-40 ... +80 °C (-40 ... +176 °F)
Vessel pressure
3 bar g (43.5 psi g)
Multi-segment alphanumeric liquid
crystal with bar graph (representing
level) available in four languages
Design
Enclosure
• Body construction
PBT (Polybutylene Terephthalate)
• Lid construction
PEI (Polyether Imide)
• Cable inlet
2 x M20x1.5 or 2 x ½" NPT with
adapter
Degree of protection
Type 4X/NEMA 4X, Type 6/
NEMA 6, IP67, IP68
Weight
1.97 kg (4.35 lb)
Antenna
• Material
Polypropylene rod, hermetically
sealed construction
• Dimensions
Standard 100 mm (4 inch) shield for
maximum 100 mm (4 inch) nozzle or
optional 250 mm (10 inch) long shield
Process connections
1½" NPT [(Taper),
ANSI/ASME B1.20.1]
R 1½" [(BSPT), EN 10226]
G 1½" [(BSPP), EN ISO 228-1]
Siemens FI 01 · 2015
4/195
4
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS Probe LR
4
Selection and Ordering data
SITRANS Probe LR
2-wire, 6 GHz pulse radar level transmitter for
continuous monitoring of liquids and slurries in
storage vessels with nominal pressure and
temperature, to a range of 20 m (66 ft).
Max. 3 bar g (43.5 psi g) pressure and
80 °C (176 °F)
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Enclosure/Cable inlet
Plastic, (PBT), 2 x ½" NPT
¢
Plastic, (PBT), 2 x M20x1.5
¢
Antenna type/Material - (max. 3 bar and 80 °C)
Polyproylene Antenna
1½" NPT [(Taper), ANSI/ASME B1.20.1],
¢
comes with integral 100 mm shield
R 1½" [(BSPT), EN 10226],
¢
comes with integral 100 mm shield
G 1½" [(BSPP), EN ISO 228-1],
¢
comes with integral 100 mm shield
1½" NPT [(Taper), ANSI/ASME B1.20.1],
¢
comes with integral 250 mm shield
R 1½" [(BSPT), EN 10226],
¢
comes with integral 250 mm shield
G 1½" [(BSPP), EN ISO 228-1],
¢
comes with integral 250 mm shield
Approvals
General Purpose, CE, R&TTE, RCM
¢
General Purpose, CSAus/c, FM, FCC
¢
CSA Class I, Div. 1, Groups A, B, C, D, Class II,
¢
Div. 1 Group G, Class III, FCC, Intrinsically Safe
FM, Class I, II and III, Div. 1, Groups A, B, C, D, E, F, G, ¢
FCC, Intrinsically Safe
IECEx Ex ia IIC T4; ATEX II 1G EEx ia IIC T4,
¢
R&TTE, RCM, Intrinsically Safe;
INMETRO Ex ia IIC T4 Ga; GOST-R
Communication/Output
4 ... 20 mA, HART
¢
Article No.
7ML5430-
Further designs
7777 0
Please add "-Z" to Article No. and specify Order
code(s).
Selection and Ordering data
Order code
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Measuring-point number/identification
(max. 27 characters) specify in plain text
Manufacturer's test certificate: M to DIN 55350,
Part 18 and to ISO 9000
1
2
A
B
C
¢ C11
Operating Instructions
Article No.
English
A5E32337711
French
7ML1998-5HR11
Spanish
7ML1998-5HR21
German
Note: The Operating Instructions should be
ordered as a separate item on the order.
A5E34957879
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
D
Additional Operating Instructions
E
Multi-language Quick Start manual
F
A5E32106153
Accessories
Handheld programmer, Intrinsically Safe,
ATEX II 1G, Ex ia
7ML5830-2AH
HART modem/USB
(for use with a PC and SIMATIC PDM)
7MF4997-1DB
D
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F)
7ML1930-1AP
E
SITRANS RD100, loop powered display see Chapter 7
7ML5741-...
SITRANS RD200, universal input display with
Modbus conversion - see Chapter 7
7ML5740-...
SITRANS RD300, dual line display with totalizer
and linearization curve and Modbus conversion see Chapter 7
7ML5744-...
SITRANS RD500 web, universal remote monitoring
solution for instrumentation - see Chapter 7
7ML5750-...
A
B
C
1
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
For applicable back up point level switch see point level measurement section
Spare parts
Plastic lid
7ML1830-1KB
For applicable back up point level switch see point level measurement section
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
4/196
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS Probe LR
■ Dimensional drawings
½" NPT cable entry
(or alternatively M20 x 1.5)
Lid
Lid screws
Enclosure /
electronics
Locking collar
mounting thread
1½" NPT,
R 1½" BSPT,
23 (0.9)
G 1½" BSPP
Inactive shield length
(internal)
Standard: 100 (4)
Optional: 250 (10)
Polypropylene
rod antenna
103.5
(4)
139
(5.5)
4
Std. 115 (4.5)
[Optional 268 (10.5)]
134
(5.3)
Std.: 273 (10.8) min.
Option: 423 (16.7) max.
Std.: 552 (21.7) min.
Option: 702 (27.6) max.
129
(5.1)
SITRANS Probe LR, dimensions in mm (inch)
■ Schematics
Hand Programmer
Connect the wires to the
terminals as shown: the
polarity is identified on the
terminal block.
Strain relief
(or NPT cable inlet)
SITRANS Probe LR
Part number: 7ML5830-2AH
Notes:
-
DC terminal shall be supplied from an SELV source in accordance with IEC-1010-1 Annex H.
All field wiring must have insulation suitable for rated input voltages.
Use shielded twisted pair cable (14-22 AWG)
Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes.
SITRANS Probe LR connections
Siemens FI 01 · 2015
4/197
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR200
■ Overview
■ Configuration
Installation
Min. 300 mm (1 ft) for every
3 m (10 ft) of vessel wall.
Note:
• Beam angle is the width of the
cone where the energy density
is half of the peak energy
density.
• Beam angle for horn antenna
dependent on horn size
• The peak energy density is
directly in front of and in line
with the rod antenna.
• There is a signal transmitted
outside of the beam angle;
therefore false targets may be
detected.
4
SITRANS LR200 is a 2-wire, 6 GHz pulse radar level transmitter
for continuous monitoring of liquids and slurries in process vessels including high temperature, pressure, agitation,
and turbulence to a range of 20 m (65 ft).
Beam
angle 28°
Mounting unit on vessel
■ Benefits
• Graphical local user interface (LUI) makes operation simple
with plug-and-play setup using the intuitive Quick Start Wizard
• LUI displays echo profiles for diagnostic support
• Communication using HART or PROFIBUS PA
• Process Intelligence signal processing for improved
measurement reliability and Auto False-Echo Suppression of
fixed obstructions
• Programming using infrared Intrinsically Safe handheld
programmer or SIMATIC PDM
■ Application
Conical
Flat
Mounting unit on stilling well
Parabolic
Mounting on a nozzle
Orient front or
back of device
toward stillpipe
slots.
Min. 10 (0.4)
SITRANS LR200’s unique design allows safe and simple
programming using the Intrinsically Safe handheld programmer
without having to open the instrument’s lid. It also features a
built-in alphanumeric display in four languages.
The SITRANS LR200 has a standard Uni-Construction polypropylene rod antenna that offers excellent chemical resistance and
is hermetically sealed. The Uni-Construction antenna features
an internal, integrated shield that eliminates vessel nozzle interference.
Start-up is easy with as few as two parameters for basic operation. Installation is simplified as the electronics are mounted on
a rotating head that swivels, allowing the instrument to line up
with conduit or wiring connections or simply to adjust the position for easy viewing. SITRANS LR200 features Process Intelligence signal-processing technology for superior reliability.
• Key Applications: liquid process vessels with agitators,
vaporous liquids, high temperatures, asphalt, digesters
4/198
Siemens FI 01 · 2015
SITRANS LR200 installation, dimensions in mm (inch)
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR200
■ Technical specifications
Mode of operation
Power supply
Measuring principle
Radar level measurement
Frequency
5.8 GHz (North America 6.3 GHz)
Measuring range
0.3 ... 20 m (1.0 ... 65 ft)
Output
• Analog output
• Accuracy
• Span
• Communications
4 ... 20 mA
± 0.02 mA
Proportional or inversely proportional
HART
• Fail-safe
Performance (according to
reference conditions IEC60770-1)
• From end of antenna to 600 mm:
• Remainder of range:
Optional: PROFIBUS PA
(Profile 3.0, Class B)
Programmable as high,
low or hold (Loss of Echo)
40 mm (1.57 inch)
10 mm (0.4 inch) or 0.1 % of span
(whichever is greater)
Rated operating conditions
PROFIBUS PA
Indoor/outdoor
Ambient conditions (enclosure)
• Ambient temperature
• Installation category
• Pollution degree
-40 ... +80 °C (-40 ... +176 °F)
I
4
Design
Enclosure
• Material
Aluminum, polyester powder coated
• Cable inlet
2 x M20x1.5 or 2 x ½" NPT with
adapter
Degree of protection
Type 4X/NEMA 4X, Type 6/ NEMA 6,
IP67, IP68
Weight
< 2.82 kg (6.21 lb)
(polypropylene rod antenna)
Display (local)
Multi-segment alphanumeric liquid
crystal with bar graph (representing
level) available in four languages
Antenna
• Material
Polypropylene rod, hermetically
sealed construction, optional PTFE
• Dimensions
Standard 100 mm (4 inch) shield for
maximum 100 mm (4 inch) nozzle,
or optional 250 mm (10 inch) long
shield
• Optional rods and horn
Refer to SITRANS LR200 Antennas
for optional rods and horns
• 10.5 mA
• Per IEC 61158-2
Certificates and approvals
CSAUS/C, CE, FM, RCM
Marine
• Lloyd’s Register of Shipping
• ABS Type Approval
Radio
FCC, Industry Canada and European
(R&TTE), RCM
Hazardous
• Intrinsically Safe (Brazil)
• Explosion Proof (Canada/USA)
• Non-incendive (USA)
r > 1.6 (for r < 3, use stillpipe)
Varies with connection type;
see Pressure/Temperature curves for
more information
Nominal 24 V DC (max. 30 V DC)
with max. 550 
Nominal 24 V DC (max. 30 V DC)
with max. 250 
General
• Intrinsically Safe (Canada/USA)
Installation conditions
• Location
Medium conditions
• Dielectric constant r
• Vessel temperature and pressure
4 ... 20 mA/HART
• General Purpose, Non-incendive,
Intrinsically Safe
• Flame proof, Increased safety,
Explosion proof
• Flame Proof/Increased Safety
(China)
• Flame Proof (Europe)
• Increased Safety (Europe)
• Intrinsically Safe (Europe)
• Intrinsically Safe (International)
• Intrinsically Safe (Russia)
INMETRO Ex ia IIC T4 Ga
CSA/FM, Class I, Div. 1,
Groups A, B, C, D; Class II, Div. 1,
Groups E, F, G; Class III, T4
CSA/FM, Class I, Div. 1,
Groups A, B, C, D; Class II, Div. 1,
Groups E, F, G; Class III, T4
FM, Class I, Div. 2, Groups A, B, C, D,
T5
NEPSI Ex d mb ia IIC T4/
Ex e mb ia IIC T4
ATEX II 1/2 G Ex d mb ia IIC T4
Ga/Gb
ATEX II 1/2 G Ex e mb ia IIC T4
Ga/Gb
ATEX II 1G Ex ia IIC T4
IECEx Ex ia IIC T4
GOST-R Ex ia
Programming
• Intrinsically Safe Siemens handheld Infrared receiver
programmer
IS model:
- Approvals for handheld
programmer
ATEX II 1GD Ex ia IIC T4 Ga
Ex iaD 20 T135 °C Ta = -20 ... +50 °C
CSA/FM Class I, II, and III, Div. 1,
Groups A, B, C, D, E, F, G, T6
Ta = +50 °C
HART communicator 375
• Handheld communicator
• PC
• SIMATIC PDM
• AMS
Multi-segment alphanumeric liquid
• Display (local)
crystal with bar graph (representing
level) available in four languages
Process connections
• Process connection
1½" NPT [(Taper),
ANSI/ASME B1.20.1]
R 1½" [(BSPT), EN 10226],
or G 1½" [(BSPP), EN ISO 228-1]
(polypropylene rod antenna)
• Flange connection
Refer to SITRANS LR200 Antennas
for more connections
Siemens FI 01 · 2015
4/199
4
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR200
Selection and Ordering data
Article No.
Selection and Ordering data
SITRANS LR200, Uni-Construction
polypropylene rod antenna version
2-wire, 6 GHz pulse radar level transmitter for
continuous monitoring of liquids and slurries in
process vessels including high temperature and
pressure, to a range of 20 m (66 ft).
Max. 3 bar g (43.5 psi g) pressure and
80 °C (176 °F)
7ML5422-
Further designs
7777 0
Please add "-Z" to Article No. and specify Order
code(s).
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Enclosure/Cable inlet
Aluminum, epoxy painted
2 x ½" NPT
2 x M20x1.5
4
Polypropylene antenna type (Max. 3 Bar pressure and 80 °C)
1½" NPT [(Taper), ANSI/ASME B1.20.1],
c/w integral 100 mm shield
R 1½" [(BSPT), EN 10226],
c/w integral 100 mm shield
G 1½" [(BSPP), EN ISO 228-1],
c/w integral 100 mm shield
1½" NPT [(Taper), ANSI/ASME B1.20.1],
c/w integral 250 mm shield
R 1½" [(BSPT), EN 10226],
c/w integral 250 mm shield
G 1½" [(BSPP), EN ISO 228-1],
c/w integral 250 mm shield
Approvals
General Purpose, CE, R&TTE, RCM
General Purpose, CSA, FM, Industry Canada, FCC
Intrinsically Safe, CSA Class I, II, Div. 1, Groups A,
B, C, D, E, F, G, Industry Canada
Intrinsically Safe, FM Class I, II, Div. 1, Groups A,
B, C, D, E, F, G, FCC
Intrinsically Safe, IECEx/ATEX II 1G Ex ia IIC T4,
INMETRO Ex ia IIC T4, CE, R&TTE, RCM; GOST-R
Non incendive, FM Class I, Div. 2, Groups A, B, C,
D, FCC1)
Increased Safety, ATEX II 1/2G Ex e mb ia IIC T4
Ga/Gb, CE, R&TTE, RCM; GOST-R2)3)
Flame Proof, ATEX II 1/2G Ex d mb ia IIC T4 Ga/
Gb, CE, R&TTE, RCM; GOST-R3)
Explosion Proof, CSA/FM Class I, II, III, Groups A,
B, C, D, E, F, G, Industry Canada, FCC1)3)
Communication/Output
PROFIBUS PA
4 ... 20 mA, HART, start-up at < 3.6 mA
1)
Available with enclosure option 2 only
2)
Available with enclosure option 3 only
3)
Available with communication option 3 only
2
3
A
B
C
Order code
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 27 characters); specify in plain text
Y15
Manufacturer's test certificate: M to DIN 55350,
Part 18 and to ISO 9000
C11
Namur NE43 compliant, device preset to failsafe
< 3.6 mA1)
N07
Operating Instructions for HART/mA device
Article No.
English
A5E32337676
German
Note: The Operating Instructions should be
ordered as a separate line item on the order.
A5E34942758
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
A5E31993614
D
Operating Instructions for PROFIBUS PA device
E
English
A5E32337680
F
German
Note: The Operating Instructions should be
ordered as a separate line item on the order.
A5E34942820
A
B
C
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
A5E32153438
D
Accessories
Handheld programmer, Intrinsically safe, EEx ia
7ML1930-1BK
7MF4997-1DB
F
HART modem/USB
(for use with a PC and SIMATIC PDM)
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F), HART2)
7ML1930-1AP
G
H
One metallic cable gland M20x1.5,
7ML1930-1AQ
rated -40 ... +80 °C (-40 ... +176 °F), PROFIBUS PA2)
J
One general purpose polymeric cable gland
M20x1.5, rated -20 ... + 80 °C (-40 ... +176 °F)
7ML1930-1AM
SITRANS RD100, loop powered display see Chapter 7
7ML5741-...
SITRANS RD200, universal input display with
Modbus conversion - see Chapter 7
7ML5740-...
SITRANS RD300, dual line display with totalizer
and linearization curve and Modbus conversion see Chapter 7
7ML5744-...
SITRANS RD500 web, universal remote monitoring
solution for instrumentation - see Chapter 7
7ML5750-...
E
2
3
For applicable back up point level switch see point level measurement section
4/200
Siemens FI 01 · 2015
1)
Available with communication option 3 only
2)
Product shipped with plastic cable gland, rated to -20 °C.
If -40 °C rating required, then metallic cable gland is recommended.
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR200
Selection and Ordering data
Article No.
Selection and Ordering data
Article No.
SITRANS LR200, Flange Adapter/PTFE Rod
Antenna Version
2-wire, 6 GHz pulse radar level transmitter for
continuous monitoring of liquids and slurries in
process vessels including high temperature and
pressure, to a range of 20 m (66 ft).
7ML5423-
SITRANS LR200, Flange Adapter/PTFE Rod
Antenna Version
2-wire, 6 GHz pulse radar level transmitter for
continuous monitoring of liquids and slurries in
process vessels including high temperature and
pressure, to a range of 20 m (66 ft).
2 x ½" NPT
2 x M20x1.5
7ML5423-
7 7 7 77 - 77 7 7
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Antenna material (uses antenna adapter)
PTFE, uses antenna adapter and
additional process connection below
Communication/Output
PROFIBUS PA
4 ... 20 mA, HART, start-up at < 3.6 mA
1
Process connection (refer to Pressure/
Temperature curves, page 4/208)
Flanges (316L stainless steel)
DN 50 PN 16, Type A, flat faced
DN 80 PN 16, Type A, flat faced
DN 100 PN 16, Type A, flat faced
DN 150 PN 16, Type A, flat faced
AA
BA
CA
DA
2" ASME 150 lb, flat faced
3" ASME 150 lb, flat faced
4" ASME 150 lb, flat faced
6" ASME 150 lb, flat faced
FB
GB
HB
JB
DN 50 PN 40, flat faced
DN 80 PN 40, flat faced
DN 100 PN 40, flat faced
DN 150 PN 40, flat faced
AC
BC
CC
DC
2" ASME 300 lb, flat faced, available with
Pressure rating option 1 only due to flange hole
spacing
3" ASME 300 lb, flat faced
4" ASME 300 lb, flat faced
6" ASME 300 lb, flat faced
FD
JIS DN 50 10K
JIS DN 80 10K
JIS DN 100 10K
JIS DN 150 10K
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5, or EN 1092-1, or JIS B 2220 standard.)
Approvals
General Purpose, CE, R&TTE, RCM
General Purpose, CSA, FM, Industry Canada, FCC
Intrinsically Safe, CSA Class I, II, Div. 1,
Groups A, B, C, D, E, F, G, Industry Canada
AE
BE
CE
DE
LA
MA
LC
R 2" [(BSPT), EN 10226]
G 1½" [(BSPP), EN ISO 228-1]
G 2" [(BSPP), EN ISO 228-1]
MC
LE
ME
B
C
A
B
C
D
Increased Safety, ATEX II 1/2G Ex e mb ia IIC T4
Ga/Gb, CE, R&TTE, RCM; GOST-R 3)4)
Flame Proof, ATEX II 1/2G Ex d mb ia IIC T4 Ga/
Gb, CE, R&TTE, RCM; GOST-R4)
Explosion Proof, CSA/FM Class I, II, III, Groups A,
B, C, D, E, F, G, Industry Canada, FCC2)4)
G
4
E
F
H
J
0
1
1)
Available with process connection options BA, CA, DA, GB, HB, JB, BC,
CC, DC, GD, HD, JD, BE, CE, DE, MA, MC, ME only
2)
Available with enclosure option 2 only
3)
Available with enclosure option 3 only
4)
Available with communication option C only
0
1
2
100 mm (4 inch) extension,
316L stainless steel shield1)
150 mm (6 inch) extension,
316L stainless steel shield1)
200 mm (8 inch) extension,
316L stainless steel shield1)
3
250 mm (10 inch) extension,
316L stainless steel shield1)
6
Process seal/gasket
Integral Gasket,
for flat faced flange process connections only,
not for Antenna extension options 3 ... 6
FKM O-ring,
not available for combination of flat faced flanges
with Antenna extension options 0, 1 or 2
2
3
Intrinsically Safe, FM Class I, II, Div. 1, Groups A,
B, C, D, E, F, G, FCC
Intrinsically Safe, IECEx/ATEX II 1G Ex ia IIC T4,
INMETRO Ex ia IIC T4, CE, R&TTE, RCM; GOST-R
Non incendive, FM Class I, Div. 2, Groups A, B, C, D,
FCC2)
Pressure rating
Rating per Pressure/Temperature curves in manual
0.5 bar g (7.25 psi g) maximum
GD
HD
JD
Threaded connection (316L stainless steel)
1½" NPT [(Taper), ANSI/ASME B1.20.1]
2" NPT [(Taper), ANSI/ASME B1.20.1]
R 1½" [(BSPT), EN 10226]
Antenna extensions or Inactive shield length
No antenna extension
50 mm (2 inch) extension, PTFE
100 mm (4 inch) extension, PTFE
7 7 7 77 - 77 7 7
4
5
0
1
Enclosure/Cable inlet
Aluminum, Epoxy painted
Siemens FI 01 · 2015
4/201
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR200
Selection and Ordering data
Order code
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
4
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 27 characters); specify in plain text
Y15
Manufacturer's test certificate: M to DIN 55350,
Part 18 and to ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Namur NE43 compliant, device preset to failsafe
< 3.6 mA3)
N07
Operating Instructions for HART/mA device
Article No.
English
A5E32337676
German
Note: The Operating Instructions should be
ordered as a separate line item on the order.
A5E34942758
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
A5E31993614
Operating Instructions for PROFIBUS PA device
English
A5E32337680
German
Note: The Operating Instructions should be
ordered as a separate line item on the order.
A5E34942820
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
A5E32153438
Accessories
Handheld programmer, Intrinsically safe, EEx ia
7ML1930-1BK
Antenna, rod, PTFE
7ML1830-1HC
Antenna extension, 50 mm (2 inch), PTFE
7ML1830-1CH
Antenna extension, 100 mm (4 inch), PTFE
7ML1830-1CG
HART modem / USB
(for use with PC and SIMATIC PDM)
7MF4997-1DB
Metallic cable gland M20 x 1.5,
rated -40 °C (-40 °F) ... 80 °C. (176 °F),
HART (two are required)
7ML1930-1AP
Metallic cable gland M20 x 1.5,
rated -40 °C (-40 °F) ... 80 °C. (176 °F),
PROFIBUS PA (two required)
7ML1930-1AQ
One General Purpose polymeric cable gland
M20 x 1.5, rating for -20°C (-4°F) ...+ 80°C. (176 °F)
7ML1930-1AM
SITRANS RD100, loop powered display see Chapter 7
7ML5741-...
SITRANS RD200, universal input display with
Modbus conversion - see Chapter 7
7ML5740-...
SITRANS RD300, dual line display with totalizer
and linearization curve and Modbus conversion see Chapter 7
7ML5744-...
SITRANS RD500 web, universal remote monitoring
solution for instrumentation - see Chapter 7
7ML5750-...
For applicable back up point level switch see point level measurement section
4/202
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR200
Selection and Ordering data
Article No.
Selection and Ordering data
Article No.
SITRANS LR200,
Flange adapter/Horn Antenna version
2-wire, 6 GHz pulse radar level transmitter for
continuous monitoring of liquids and slurries in
process vessels including high temperature and
pressure, to a range of 20 m (66 ft).
7ML542577 7 77 - 77 77
SITRANS LR200,
Flange adapter/Horn Antenna version
2-wire, 6 GHz pulse radar level transmitter for
continuous monitoring of liquids and slurries in
process vessels including high temperature and
pressure, to a range of 20 m (66 ft).
7ML54257 7 7 77 - 77 7 7
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Antenna material (uses antenna adapter)
316L stainless steel with PTFE cone emitter
316L stainless steel with PTFE cone emitter and
purge connection with 1/8" NPT inlet1)
Sliding waveguide system with 1 000 mm (40 inch)
waveguide1)2)
Process connection (refer to Pressure/
Temperature curves, page 4/209)
Flanges (316L stainless steel)
DN 50 PN 16 EN 1092-1 Type A flat faced1)
DN 80 PN 16 EN 1092-1 Type A flat faced
DN 100 PN 16 EN 1092-1 Type A flat faced
DN 150 PN 16 EN 1092-1 Type A flat faced
DN 200 PN 16 EN 1092-1 Type A flat faced
DN 80 PN 10/16 DIN EN 1092-1 Type B1 raised face3)
DN 100 PN 10/16 DIN EN 1092-1 Type B1 raised face3)
DN 150 PN 10/16 DIN EN 1092-1 Type B1 raised face3)
DN 200 PN 16 DIN EN 1092-1 Type B1 raised face3)
2" ASME 150 lb, flat faced1)
3" ASME 150 lb, flat faced
4" ASME 150 lb, flat faced
6" ASME 150 lb, flat faced
8" ASME 150 lb, flat faced
DN 50 PN 40, flat faced3)
DN 80 PN 40, flat faced3)
DN 100 PN 40, flat faced3)
DN 200 PN 40, flat faced3)
DN 80 PN 25/40 DIN EN 1092-1 Type B1 raised face3)
DN 100 PN 25/40 DIN EN 1092-1 Type B1 raised
face3)
DN 150 PN 25/40 DIN EN 1092-1 Type B1 raised
face3)
2" ASME 300 lb, flat faced1)3)
3" ASME 300 lb, flat faced3)
4" ASME 300 lb, flat faced3)
JIS DN 50 10K1)
JIS DN 80 10K
JIS DN 100 10K
JIS DN 150 10K
JIS DN 200 10K
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5, or EN 1092-1, or JIS B 2220 standard.)
Communication/Output
PROFIBUS PA
4 ... 20 mA, HART, start-up at < 3.6 mA
Process seal/gasket
FKM (-40 ... +200 °C)
Nitrile (-40 ... +60 °C),
sliding waveguide systems only
FFKM (-35 ... +200 °C)
Enclosure/Cable inlet
Aluminum, Epoxy painted
2 x ½" NPT
2 x M20x1.5
Horn size/Waveguide options
80 mm (3 inch) horn4)
100 mm (4 inch) horn4)
150 (6 inch) mm horn
200 (8 inch) mm horn
100 mm (4 inch) horn with 100 mm (4 inch)
waveguide extension4)
100 mm (4 inch) horn with 150 mm (6 inch)
waveguide extension4)
100 mm (4 inch) horn with 200 mm (8 inch)
wave-guide extension4)
100 mm (4 inch) horn with 250 mm (10 inch)
waveguide extension4)
150 mm (6 inch) horn with 100 mm (4 inch)
waveguide extension
150 mm (6 inch) horn with 150 mm (6 inch)
waveguide extension
150 mm (6 inch) horn with 200 mm (8 inch)
waveguide extension
0
1
2
AA
BA
CA
DA
EA
BF
CF
DF
EF
FB
GB
HB
JB
KB
AC
BC
CC
EC
150 mm (6 inch) horn with 250 mm (10 inch)
waveguide extension
200 mm (8 inch) horn with 100 mm (4 inch)
waveguide extension
200 mm (8 inch) horn with 150 mm (6 inch)
waveguide extension
200 mm (8 inch) horn with 200 mm (8 inch)
waveguide extension
200 mm (8 inch) horn with 250 mm (10 inch)
waveguide extension
(Add Order code Y01 and plain text:
"waveguide length ... mm")
CG
DG
EG
FD
GD
HD
AE
BE
CE
DE
EE
0
1
2
2
3
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
1
2
Siemens FI 01 · 2015
4/203
4
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR200
Selection and Ordering data
Article No.
Selection and Ordering data
SITRANS LR200,
Flange adapter/Horn Antenna version
2-wire, 6 GHz pulse radar level transmitter for
continuous monitoring of liquids and slurries in
process vessels including high temperature and
pressure, to a range of 20 m (66 ft).
7ML542577 7 77 - 77 77
Further designs
Approvals
General Purpose, CE, R&TTE, RCM
General Purpose, CSA, FM, Industry Canada, FCC
Intrinsically Safe, CSA Class I, II, Div. 1, Groups A,
B, C, D, E, F, G, Industry Canada
Intrinsically Safe, FM Class I, II, Div. 1, Groups A, B,
C, D, E, F, G, FCC
Intrinsically Safe, IECEx/ATEX II 1G Ex ia IIC T4,
INMETRO Ex ia IIC T4, CE, R&TTE, RCM; GOST-R
Non incendive, FM Class I, Div. 2, Groups A, B, C, D,
FCC5)
4
Increased Safety, ATEX II 1/2G Ex e mb ia IIC T4
Ga/Gb, CE, R&TTE, RCM; GOST-R6)7)
Flame Proof, ATEX II 1/2G Ex d mb ia IIC T4 Ga/Gb,
CE, R&TTE, RCM; GOST-R7)
Explosion Proof, CSA/FM Class I, II, III, Groups A,
B, C, D, E, F, G, Industry Canada, FCC5)7)
Pressure rating
Rating per Pressure/Temperature curves in manual
0.5 bar g (7.25 psi g) maximum
1)
Available with pressure rating option 1 only
2)
Maximum Process Temperature 60 °C (140 °F)
3)
Available with Antenna Material option 0 and 1 only
4)
For stillpipe applications only
5)
Available with enclosure option 2 only
6)
Available with enclosure option 3 only
7)
Available with communication option 2 only
Order code
Please add "-Z" to Article No. and specify Order
code(s).
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 27 characters); specify in plain text
Y15
A
B
C
Manufacturer's test certificate: M to DIN 55350,
Part 18 and to ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
D
Namur NE43 compliant, device preset to failsafe
< 3.6 mA1)
N07
E
Operating Instructions for HART/mA device
Article No.
F
English
A5E32337676
A5E34942758
G
German
Note: The Operating Instructions should be
ordered as a separate line item on the order.
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
A5E31993614
H
J
0
1
Operating Instructions for PROFIBUS PA device
English
A5E32337680
German
Note: The Operating Instructions should be
ordered as a separate line item on the order.
A5E34942820
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
A5E32153438
Accessories
Handheld programmer, Intrinsically safe, EEx ia
7ML1930-1BK
HART modem/USB
(for use with a PC and SIMATIC PDM)
7MF4997-1DB
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F), HART2)
7ML1930-1AP
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F),
PROFIBUS PA3)
7ML1930-1AQ
One general purpose polymeric cable gland
M20x1.5, rated -40 ... +80 °C (-40 ... +176 °F)
7ML1930-1AM
SITRANS RD100, loop powered display see Chapter 7
7ML5741-...
SITRANS RD200, universal input display with
Modbus conversion - see Chapter 7
7ML5740-...
SITRANS RD300, dual line display with totalizer
and linearization curve and Modbus conversion see Chapter 7
7ML5744-...
SITRANS RD500 web, universal remote monitoring
solution for instrumentation - see Chapter 7
7ML5750-...
For applicable back up point level switch see point level measurement section
4/204
Siemens FI 01 · 2015
1)
Available with communication option 2 only
2)
Product shipped with plastic cable gland, rated to -20 °C.
If -40 °C rating required, then metallic cable gland is recommended.
3)
Available with enclosure option 2 only
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR200
■ Dimensional drawings
SITRANS LR200 with polypropylene
shielded rod antenna
PTFE rod antenna, threaded
Threaded connection
PTFE rod, external shield
½” NPT cable entry
(or alternatively M20 x 1.5 cable gland)
Nameplate
Nameplate
Threaded cover
187 (7.4)
154
(6)
Reference point
AISI 316,
2” NPT,
R 2” (BSPT)
or G 2” (BSPP)
185
(7.3)
Enclosure/
electronics
158
(6.1)
Reference point
AISI 316,
17
2” NPT,
(0.67)
R 2” (BSPT)
or G 2” (BSPP)
Antenna shield
(inactive length)
AISI 316
PTFE
antenna
Locking ring
412
(16.3)
Reference point
Std. 296 (11.7) min.
Option: 446 (17.6) max.
18
(0.7)
S.L.
L
Shield Length (S.L.):
min. 100 (4)
(customer specified)
Overall Length (L):
374 (14.7) plus
shielded length
Shield length (internal):
Standard: 100 (4)
Optional: 250 (10)
Mounting
thread
Active antenna
(PTFE)
187
(7.4)
Polypropylene
rod antenna
Std. 575 (22.6) min.
Option: 725 (28.5) max.
Horn antenna with flat faced flange
Enclosure/electronics
Nameplate
187
(7.4)
Sliding waveguide
Locking ring
Reference point
Flange
Nameplate
Ø80 (3)
Horn
187
(7.4)
Reference point
131
(5.16)
100
(4)
225.8
(8.89)
325.1
(12.79)
150 (6)
40
(1.6)
200 (8)
Sliding flange
1 000
(40.8)
934
(36.8)
111
(4.40)
100 (4)
206
(8.11)
305
(12.01)
150 (6)
200 (8)
Fully inserted length =
934 mm + horn height
SITRANS LR200, dimensions in mm (inch)
Siemens FI 01 · 2015
4/205
4
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR200
■ Schematics
Connect the wires to the
terminals as shown: the
polarity is identified on the
terminal block.
4
Gland
Hand programmer
Shield for HART and
PROFIBUS PA
intrinsically safe
versions only.
Part number:
7ML1930-1BK
Notes:
1.
2.
3.
4.
DC terminal shall be supplied from an SELV source in accordance with IEC 1010-1 Annex H.
All field wiring must have insulation suitable for rated input voltages.
Use shielded twisted pair cable (14 ... 22 AWG) for HART version.
Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes.
SITRANS LR200 connections
4/206
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR200 Antennas
■ Integration
Horn with waveguide
extension. Used for high
temperature isolation, long
standpipes, and clearing
tank obstructions.
Sliding waveguide antenna,
typically for digester applications
that include an isolation valve
between the instrument and the vessel.
Flat faced flange
connection with
PTFE rod antenna.
Shielded rod antenna
with a stainless steel
shield eliminates
standpipe interference.
Various lengths
available.
SITRANS LR200 with flange
adapter for connection to
optional antennas.
Antenna configurations for SITRANS LR200
■ Technical specifications
Antenna Types
Flat Faced Flange with Rod
Shielded Rod
Horn (4", 6", 8" sizes available)
Connection type
Flat faced flange
nominal pipe sizes 50, 80, 100,
150 mm (2, 3, 4, 6 inch)
Threaded 2" NPT, R 2" (BSPT),
G 2" (BSPP) or flat faced flange
nominal pipe sizes 80, 100 mm
(3, 4 inch)
Flat faced flange
nominal pipe sizes 50, 80, 100,
150 mm (2, 3, 4, 6 inch)
Wetted parts
PTFE
PTFE, 316L stainless steel, FKM o-ring 316L stainless steel
PTFE, FKM o-ring
Extensions
50 or 100 mm (2 or 4 inch)
PTFE or UHMW-PE
100, 150, 200 or 250 mm
(4, 6, 8 or 10 inch)
standard shield length
Use waveguide for extensions to 6 m
(20 ft) long
Dielectric constant
>3
>3
>3
Insertion length (max.)
41 cm (16.3 inch)
Variable
Variable with extension
Purging option (liquid or gas)
No
No
Yes
Sliding waveguide option for
digesters1)
Yes
No
Yes
Weight2)
6.5 kg (14.3 lb)
5.0 kg (11 lb)
7.5 kg (16.5 lb)
1)
Maximum pressure 0.5 bar g at 60 °C (7.25 psi g at 140 °F)
2)
Not including extensions, includes SITRANS LR200 and smallest process connection
Siemens FI 01 · 2015
4/207
4
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR200 Antennas
■ Characteristic curves
Ambient temperature (°C)
Maximum flange and process temperatures versus allowable ambient temperature
90
130 °C
80
70
67 °C
60
50
Polypropylene rod
40
PTFE rod/
horn antenna
30
20
4
10
0
0
20
40
60
80
100
120
140
160
180
200
220
Process flange surface temperature (°C)
SITRANS LR200 Ambient/Process Flange Surface Temperature Curve
4/208
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR200 Antennas
PTFE rod antenna with
integral gasket 150# and PN 16 sizes
flange series 22452, 316 stainless steel, flat face
16.0
Pressure (bar, gauge)
14.0
(A)
(B)
12.0
10.0
(C)
8.0
6.0
4.0
(A) 22452 50 mm/2 inch nom.
2.0
(B) 22452 80 mm/3 inch nom.
0.0
-40 -20
(C) 22452 100 mm/4 inch nom.
0
20
40
4
60 80 100 120 140 160 180 200
Temperature (°C)
Horn antenna and/or wave guide with
PTFE ermitter 150# and PN 16 sizes
flange series 22452, 316 stainless steel, flat face
16.0
(E)
Pressure (bar, gauge)
14.0
(D)
12.0
10.0
(F)
8.0
6.0
(D) 22452 80 mm/3 inch nom.
(G)
4.0
(E) 22452 100 mm/4 inch nom.
2.0
(F) 22452 150 mm/6 inch nom.
0.0
-50
(G) 22452 200 mm/8 inch nom.
0
50
100
Temperature (°C)
150
200
Threaded process
1.5" & 2" NPT, BSP, & G
40.0
Pressure (bar, gauge)
35.0
30.0
25.0
(H) 1.5" and 2", thread connection
20.0
15.0
10.0
(H)
5.0
0.0
-50
0
50
100
Temperature (°C)
150
200
SITRANS LR200 Process Pressure/Temperature derating curves
Siemens FI 01 · 2015
4/209
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR200 Specials
■ Selection and ordering data
SITRANS LR200 Specials
SITRANS LR200 Specials
Article No.
SITRANS LR200 PROFIBUS PA Aluminum
Enclosure Kit with electronics and covers
(7ML5422, 7ML5423, 7ML5424, 7ML5425),
calibrated for use with standard rod antenna
4
SITRANS LR200 aluminum enclosure
with board stack, LUI display, 5.8 GHz, M20
cable inlet, approval option E, with PROFIBUS
PA communication, no process connection.5)
A5E01483420
SITRANS LR200 aluminum enclosure
with board stack, LUI display, 5.8 GHz, M20
cable inlet, approval option A, with PROFIBUS
PA communication, no process connection.5)
A5E01483440
SITRANS LR200 aluminum enclosure
with board stack, LUI display, 6.3 GHz, M20
cable inlet, approval option C, with PROFIBUS
PA communication, no process connection.5)
A5E01483456
SITRANS LR200 aluminum enclosure
with board stack, LUI display, 6.3 GHz, NPT
cable inlet, approval option C, with PROFIBUS
PA communication, no process connection.5)
A5E01483547
SITRANS LR200 aluminum enclosure
with board stack, LUI display, 5.8 GHz, NPT
cable inlet, approval option E, with PROFIBUS
PA communication, no process connection.5)
A5E01483559
SITRANS LR200 HART aluminum enclosure
kit with electronics and covers (7ML5422,
7ML5423, 7ML5424, 7ML5425), calibrated for
use with standard rod antenna
Article No.
SITRANS LR200 aluminum enclosure
with board stack, LUI display, 5.8 GHz, NPT
cable inlet, approval option A, with HART
communication start-up at < 3.6 mA,
no process connection.5)
A5E03617085
SITRANS LR200 aluminum enclosure
with board stack, LUI display, 6.3 GHz, NPT
cable inlet, approval option B, with HART
communication start-up at < 3.6 mA,
no process connection.5)
A5E03617086
SITRANS LR200 aluminum enclosure
with board stack, LUI display, 5.8 GHz, NPT
cable inlet, approval option C, with HART
communication start-up at < 3.6 mA,
no process connection.5)
A5E03617087
SITRANS LR200 aluminum enclosure
with board stack, LUI display, 6.3 GHz, NPT
cable inlet, approval option E, with HART
communication start-up at < 3.6 mA,
no process connection.5)
A5E03617088
SITRANS LR200 Horn Antenna Kits
with mounting screws
(no emitter supplied)
80 mm (3 inch) horn antenna kit
PBD:25500K02A
100 mm (4 inch) horn antenna kit
PBD:25500K03A
150 mm (6 inch) horn antenna kit
PBD:25500K05A
200 mm (8 inch) horn antenna kit
PBD:25500K07A
SITRANS LR200 Extension Kits for
Horn Antenna with mounting screws
SITRANS LR200 aluminum enclosure
with board stack, LUI display, 5.8 GHz, M20
cable inlet, approval option A, with HART
communication start-up at < 3.6 mA,
no process connection.5)
A5E02956419
SITRANS LR200 aluminum enclosure
with board stack, LUI display, 5.8 GHz, M20
cable inlet, approval option E, with HART
communication start-up at < 3.6 mA,
no process connection.5)
A5E02956420
SITRANS LR200 aluminum enclosure
with board stack, LUI display, 5.8 GHz, M20
cable inlet, approval option G, with HART
communication start-up at < 3.6 mA,
no process connection.5)
A5E02956421
SITRANS LR200 aluminum enclosure
with board stack, LUI display, 5.8 GHz, M20
cable inlet, approval option H, with HART
communication start-up at < 3.6 mA,
no process connection.5)
A5E02956422
4/210
Siemens FI 01 · 2015
100 mm (4 inch) extension kit for horn antenna
PBD:25501K0100A
150 mm (6 inch) extension kit for horn antenna
PBD:25501K0150A
200 mm (8 inch) extension kit for horn antenna
PBD:25501K0200A
250 mm (10 inch) extension kit for horn antenna
PBD:25501K0250A
500 mm (20 inch) extension kit for horn antenna
PBD:25501K0500A
1 000 mm (40 inch) extension kit for
horn antenna
PBD:25501K1000A
SITRANS LR200 Flanged Rod Antenna Kit
with 316L stainless steel flat faced flanges
Flanged PTFE rod antenna kit, 2" ASME, 150 lb.
See drawing 51003 on
http://www.siemens.com/radar1)4)
PBD:
51003K020AAAA
Flanged PTFE rod antenna kit, DN 50 PN 16.
See drawing 51003 on
http://www.siemens.com/radar1)4)
PBD:
51003K050AJAA
Flanged PTFE rod antenna kit,
JIS 10K DN 50. See drawing 51003 on
http://www.siemens.com/radar1)4)
PBD:
51003K050AOAA
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR200 Specials
SITRANS LR200 Specials
SITRANS LR200 Specials
Article No.
SITRANS LR200 PTFE Rod Antenna Kit with
316L stainless steel 1½"pipe thread process
connection
Article No.
SITRANS LR200 PTFE Rod Antenna Kit
(100 mm shield) with 316L stainless steel
2" pipe thread process connection
PTFE rod antenna kit, 1½" NPT 316L stainless
steel process connection, FKM O-ring;
See drawing 51004 on
http://www.siemens.com/radar4)
PBD:
51004K1AAA
PTFE rod antenna kit, R 1½" (BSPT),
EN 10226 316L stainless steel process connection, FKM O-ring; see drawing 51004 on
http://www.siemens.com/radar4)
PBD:
51004K2AAA
PTFE rod antenna kit, 1½" G 316L stainless
steel process connection, FKM O-ring;
see drawing 51004 on
http://www.siemens.com/radar4)
PBD:
51004K3AAA
SITRANS LR200 PTFE Rod Antenna Kit with
316L stainless steel 2" pipe thread process
connection
PTFE rod antenna shielded kit, 2" NPT 316L
stainless steel process connection,
FKM O-ring, 100 mm 316L stainless steel
shield. See drawing 51002 on
http://www.siemens.com/radar3)4)
PBD:
51002K0100AAA
PTFE rod antenna shielded kit, R 2" (BSPT),
EN 10226 316L stainless steel process connection, FKM O-ring, 100 mm 316L stainless steel
shield. See drawing 51002 on
http://www.siemens.com/radar3)4)
PBD:
51002K0100BAA
PTFE rod antenna shielded kit, 2" G 316L
stainless steel process connection,
FKM O-ring, 100 mm 316L stainless steel
shield. See drawing 51002 on
http://www.siemens.com/radar3)4)
PBD:
51002K0100CAA
SITRANS LR200 Horn Antenna Kit with 316L
stainless steel flat faced flange, with PTFE
emitter (without waveguide)
PTFE rod antenna kit, 2" NPT 316L stainless
steel process connection, FKM O-ring;
see drawing 51005 on
http://www.siemens.com/radar4)
PBD:
51005K1AAA
PTFE rod antenna kit, R 2" (BSPT),
EN 10226 316L stainless steel process connection, FKM O-ring; see drawing 51005 on
http://www.siemens.com/radar4)
PBD:
51005K2AAA
PTFE rod antenna kit, 2" G 316L stainless steel
process connection, FKM O-ring;
see drawing 51005 on
http://www.siemens.com/radar4)
PBD:
51005K3AAA
Horn antenna kit, 2" ASME 316L stainless steel
flange 3" horn, PTFE emitter1)4)
PBD:
51006K020AAAA
Horn antenna kit, 2" ASME 316L stainless steel
flange 4" horn, PTFE emitter1)2)
PBD:
51006K020AABA
Horn antenna kit, 2" ASME 316L stainless steel
flange 6" horn, PTFE emitter1)2)
PBD:
51006K020AACA
Horn antenna kit, 2" ASME 316L stainless steel
flange 8" horn, PTFE emitter1)2)
PBD:
51006K020AADA
Horn antenna kit, DN 50 PN 16 316L stainless
steel flange 80 mm horn, PTFE emitter1)2)
PBD:
51006K050AJAA
Horn antenna kit, DN 50 PN 16 316L stainless
steel flange 100 mm horn, PTFE emitter1)2)
PBD:
51006K050AJBA
Horn antenna kit, DN 50 PN 16 316L stainless
steel flange 150 mm horn, PTFE emitter1)2)
PBD:
51006K050AJCA
Horn antenna kit, DN 50 PN 16 316L stainless
steel flange 200 mm horn, PTFE emitter1)2)
PBD:
51006K050AJDA
Siemens FI 01 · 2015
4/211
4
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR200 Specials
SITRANS LR200 Specials
SITRANS LR200 Specials
Article No.
SITRANS LR200 PTFE flanged rod antenna
kit with 316L stainless steel shield and 316L
stainless steel flat faced flange
Article No.
PTFE paste
Kit, PTFE paste, Tube, 250 mL
PBD:51036065
Cable gland
4
PTFE shielded rod antenna kit, flanged,
3" ASME 150 lb 316L stainless steel flange,
100 mm 316L stainless steel shield.1)4)
PBD:
51014K0100AAA
PTFE shielded rod antenna kit, flanged,
DN 80 PN 16 316L stainless steel flange,
100 mm 316L stainless steel shield.1)4)
PBD:
51014K0100EJA
PTFE shielded rod antenna kit, flanged,
3" ASME 150 lb 316L stainless steel flange,
150 mm 316L stainless steel shield.1)4)
PBD:
51014K0150AAA
PTFE shielded rod antenna kit, flanged,
DN 80 PN 16 316L stainless steel flange,
150 mm 316L stainless steel shield.1)4)
PBD:
51014K0150EJA
PTFE shielded rod antenna kit, flanged,
3" ASME 150 lb 316L stainless steel flange,
200 mm 316L stainless steel shield.1)4)
PBD:
51014K0200AAA
PTFE shielded rod antenna kit, flanged,
DN 80 PN 16 316L stainless steel flange,
200 mm 316L stainless steel shield.1)4)
PBD:
51014K0200EJA
PTFE shielded rod antenna kit, flanged,
3" ASME 150 lb 316L stainless steel flange,
250 mm 316L stainless steel shield.1)4)
PBD:
51014K0250AAA
PTFE shielded rod antenna kit, flanged,
DN 80 PN 16 316L stainless steel flange,
250 mm 316L stainless steel shield.1)4)
PBD:
51014K0250EJA
4/212
Siemens FI 01 · 2015
One polymeric cable gland M20x1.5,
rated -20 ... +80 °C (-4 ... +176 °F) for
General Purpose and ATEX EEx e
7ML1930-1AN
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F), HART
7ML1930-1AP
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F),
PROFIBUS PA
7ML1930-1AQ
Please contact [email protected] for special requests.
1)
Available in flange sizes including ASME, DIN and JIS:
please contact [email protected]
2)
Available with no pressure rating
3)
Available in other shield lengths:
please contact [email protected]
4)
Available with Pressure rating; serial number of original
unit required with completed Application Questionnaire found
on page 4/193.
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Horn Antenna
■ Overview
■ Configuration
Installation
Note:
• Beam angle is the width of the
cone where the energy density
is half of the peak energy
density.
• The peak energy density is
directly in front of and in line
with the horn antenna.
• There is a signal transmitted
outside of the beam angle;
therefore false targets may be
detected.
• Use largest possible antenna.
SITRANS LR250 is a 2-wire, 25 GHz pulse radar level transmitter
for continuous monitoring of liquids and slurries in storage and
process vessels including high temperature and pressure,
to a range of 20 m (66 ft).
Mounting unit on bypass
Orient front or back of
device toward vent.
beam width:
1.5 horn = 19°
2.0 horn = 15°
3.0 horn = 10°
4.0 horn = 8°
19°
4
Mounting unit on
stilling well
Orient front or back of device
toward stillpipe slots.
■ Benefits
Use largest
horn size
possible in
pipe.
Mounting unit on vessel
Mounting on a nozzle
Min. 10 (0.4)
• Graphical local user interface (LUI) makes operation simple
with plug-and-play setup using the intuitive Quick Start Wizard
• LUI displays echo profiles for diagnostic support
• 25 GHz high frequency allows for small antennas for easy
mounting in nozzles
• Insensitive to mounting location and obstructions, and less
sensitive to nozzle interference
• Short blanking distance for improved minimum measuring
range to 50 mm (2 inch) from the end of the antenna
• Communication using HART, PROFIBUS PA,
or FOUNDATION Fieldbus
• Process Intelligence signal processing for improved
measurement reliability and Auto False-Echo Suppression of
fixed obstructions
• Programming using infrared Intrinsically Safe handheld
programmer or over a network using SIMATIC PDM, Emerson
AMS, or Field Device Tools, such as PACTware or Fieldcare via
SITRANS DTM
• Functional Safety (SIL 2). Device suitable for use in accordance with IEC 61508 and IEC 61511
• 3 mm (0.118 inch) accuracy in accordance with IEC 60770-1
■ Application
SITRANS LR250 includes a graphical local user interface (LUI)
that improves setup and operation by including an intuitive
Quick Start Wizard, and echo profile displays for diagnostic support. Start-up is easy using the Quick Start wizard with a few
parameters required for basic operation.
The 25 GHz frequency creates a narrow, focused beam allowing
for smaller horn antenna options and decreasing sensitivity to
obstructions.
SITRANS LR250’s unique design allows safe and simple
programming using the Intrinsically Safe handheld programmer
without saving to open the instrument’s lid.
SITRANS LR250 installation, dimensions in mm (inch)
SITRANS LR250 measures superbly on low dielectric media,
and in small vessels, as well as tall and narrow vessels.
• Key Applications: liquid bulk storage tanks, process vessels,
vaporous liquids, high temperatures, low dielectric media and
applications with functional safety requirements
Siemens FI 01 · 2015
4/213
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Horn Antenna
■ Technical specifications
Mode of operation
Measuring principle
Radar level measurement
Frequency
K-band (25.0 GHz)
Minimum measuring range
50 mm (2 inch) from end of antenna
Maximum measuring range
20 m (65 ft), antenna dependent
Output
HART:
• Analog output
• Accuracy
• Fail-safe
4
PROFIBUS PA:
• Function blocks
FOUNDATION Fieldbus
• Functionality
• Version
• Function blocks
Process connections
• Process connection
R 1½", 2" or 3" [(BSPT),
EN 10226]
• Flange connection
Version 5.1
4 ... 20 mA
± 0.02 mA
• Programmable as high low or hold
(loss of echo)
• NE 43 programmable
Profile 3.01
2 Analog Input (AI)
H1
Basic or LAS
ITK 5.2.0
2 Analog Input (AI)
Performance (according to reference conditions IEC60770-1)
Maximum measured error
3 mm (0.118 inch)
Influence of ambient temperature
< 0.003 %/K
Rated operating conditions
Indoor/outdoor
Ambient conditions (enclosure)
• Ambient temperature
• Installation category
• Pollution degree
-40 ... +80 °C (-40 ... +176 °F)
I
4
50, 80, 100 mm (PN 16, 40, JIS 10K)
4 ... 20 mA/HART
Nominal 24 V DC (max. 30 V DC) with
max. 550 
PROFIBUS PA
• 15 mA
• Per IEC 61158-2
FOUNDATION Fieldbus
• 20.0 mA
• Per IEC 61158-2
Certificates and approvals
General
CSAUS/C, CE, FM, NE 21, RCM
Radio
FCC, Industry Canada and
Europe ETSI EN 302-372, RCM
Hazardous
• Explosion Proof (Brazil)
• Intrinsically Safe (Brazil)
• Explosion Proof (Canada/USA)
• Intrinsically Safe (Canada/USA)
Medium conditions
Dielectric constant r
> 1.6, antenna and application
dependent
Process temperature
-40 ... +200 °C (-40 ... +392 °F)
(at process connection with
FKM O-ring)
-20 ... +200 °C (-4 ... +392 °F)
(at process connection with
FFKM O-ring)
Process pressure
Design
Enclosure
• Material
• Cable inlet
Degree of protection
Weight
Display (local)
• Non-incendive (Canada/USA)
• Flame Proof/Increased Safety
(China)
• Intrinsically Safe (China)
• Non-sparking (China)
• Intrinsically Safe (Europe)
• Non-sparking (Europe)
• Flame Proof (International/Europe)
• Increased Safety
(International/Europe)
Aluminum, polyester powder-coated
2 x M20x1.5 or 2 x ½" NPT
Type 4X/NEMA 4X, Type 6/NEMA 6,
IP67, IP68
< 3 kg (6.6 lb) 3.75 mm (1½ inch)
threaded connection with 1½" horn
antenna
Graphic local user interface including
quick start wizard and echo profile
display
• Intrinsically Safe (International)
•
•
•
•
Explosion Proof (Russia)
Increased Safety (Russia)
Intrinsically Safe (Russia)
Marine
• Functional Safety
Antenna
• Material
• Dimensions (nominal horn sizes)
4/214
Up to 40 bar g (580 psi g), process
connection and temperature dependent.
See Pressure/Temperature curves for
more information
Siemens FI 01 · 2015
316L stainless steel [optional alloy
N06022/2.4602
(Hastelloy C-22 or equivalent)]
Standard 1.5 inch (40 mm),
2 inch (48 mm), 3 inch (75 mm),
4 inch (95 mm) horn and optional
100 mm (4 inch) horn extension
G 1½", 2" or 3" [(BSPP),
EN ISO 228-1]
2", 3", 4" (ANSI 150, 300 lb),
Power supply
• Increased Safety (Brazil)
Installation conditions
• Location
1½", 2" or 3" NPT [(Taper),
ANSI/ASME B1.20.1]
INMETRO Ex d ia mb IIC T4 Ga/Gb,
Ex ia ta IIIC T100 °C Da
INMETRO Ex e ia mb IIC T4 Ga/Gb,
Ex ia ta IIIC T100 °C Da
INMETRO Ex ia IIC T4 Ga, Ex ia ta
IIIC T100 °C Da
CSA/FM Class I, Div. 1,
Groups A, B, C, D; Class II, Div. 1,
Groups E, F, G; Class III T4
CSA/FM Class I, Div. 1,
Groups A, B, C, D; Class II, Div. 1,
Groups E, F, G; Class III T4
CSA/FM Class I, Div. 2,
Groups A, B, C, D T5
NEPSI Ex d ia mb IIC T4 Ga/Gb,
Ex e ia mb IIC T4 Ga/Gb, Ex iaD 20
T90 IP67 DIP A20 TA90 ºC
NEPSI Ex ia IIC T4 Ga, Ex iaD 20 T90
IP67 DIP A20 TA90 ºC
NEPSI Ex nA IIC T4 Gc
ATEX II 1G Ex ia IIC T4 Ga
ATEX II 1D Ex ia IIIC T100 °C Da
ATEX II 3G Ex nA IIC T4 Gc
IECEx/ATEX II 1/2 GD, 1D, 2D,
Ex d mb ia IIC T4 Ga/Gb, Ex ia ta IIC
T100 °C Da
IECEx/ATEX II 1/2 GD, 1D, 2D,
Ex e mb ia IIC T4 Ga/Gb, Ex ia ta IIIC
T100 °C Da
IECEx/ATEX II 1 G Ex ia IIC T4 Ga,
IECEX/ATEX II 1D Ex ia ta IIC T100 °C
Da
GOST-R Ex d
GOST-R Ex e
GOST-R Ex ia
• Lloyd's Register of Shipping
• ABS Type Approval
• Bureau Veritas
SIL-2 suitable in accordance with
IEC 61508/61511
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Horn Antenna
Programming
• Intrinsically Safe Siemens handheld Infrared receiver
programmer
IS model:
- Approvals for handheld
ATEX II 1 GD Ex ia IIC T4 Ga
programmer
Ex ia D 20 T135 °C Ta = -20 ... +50 °C
CSA/FM Class I, II, III, Div. 1,
Groups A, B, C, D, E, F, G, T6
Ta = +50 °C
IECEx SIR 09.0073
HART communicator 375/475
• Handheld communicator
• SIMATIC PDM
• PC
• Emerson AMS
• SITRANS DTM (for connection into
FDT, such as PACTware or
Fieldcare)
Graphic local user interface including
• Display (local)
quick start wizard and echo profile
displays
4
Siemens FI 01 · 2015
4/215
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Horn Antenna
4
Selection and Ordering data
Article No.
Selection and Ordering data
Article No.
SITRANS LR250 horn antenna
2-wire, 25 GHz pulse radar level transmitter for
continuous monitoring of liquids and slurries in
storage and process vessels including high
temperature and pressure, to a range of 20 m
(66 ft) (antenna dependent). Ideal for small vessels
and low dielectric media.
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
7ML54317 7 7 7 0 - 777 7
SITRANS LR250 horn antenna
2-wire, 25 GHz pulse radar level transmitter for
continuous monitoring of liquids and slurries in
storage and process vessels including high
temperature and pressure, to a range of 20 m
(66 ft) (antenna dependent). Ideal for small vessels
and low dielectric media.
Flanged connection Hastelloy C
2" Class 150 ASME B16.5 raised faced4)
3" Class 150 ASME B16.5 raised faced4)
4" Class 150 ASME B16.5 raised faced4)
2" Class 300 ASME B16.5 raised faced4)
3" Class 300 ASME B16.5 raised faced4)
4" Class 300 ASME B16.5 raised faced4)
7ML54317 7 7 7 0 - 777 7
Process Connection and Antenna Material
316L (1.4435 or 1.4404) stainless steel,
¢
PTFE emitter, FKM seal1)
316L (1.4435 or 1.4404) stainless steel,
¢
PTFE emitter, FFKM seal1)
Hastelloy C-22/2.4602 (or equivalent), PTFE emitter,
FKM seal2)
Hastelloy C-22/2.4602 (or equivalent), PTFE emitter,
FFKM seal2)
Process Connection Type
Threaded connection 316L
1½" NPT (ASME B1.20.1) (tapered thread)3)
R 1½" [(BSPT), EN 10226-1] (tapered thread)3)
G 1½" [(BSPP), EN ISO 228-1]
(parallel thread)3)
2" NPT (ASME B1.20.1) (tapered thread)
R 2" [(BSPT), EN 10226-1] (tapered thread)
G 2" [(BSPP), EN ISO 228-1] (parallel thread)
3" NPT (ASME B1.20.1) (tapered thread)
R 3" [(BSPT), EN 10226-1] (tapered thread)
G 3" [(BSPP), EN ISO 228-1] (parallel thread)
Flanged connection 316L
2" Class 150 ASME B16.5 flat faced4)
3" Class 150 ASME B16.5 flat faced4)
4" Class 150 ASME B16.5 flat faced4)
2" Class 300 ASME B16.5 flat faced4)
3" Class 300 ASME B16.5 flat faced4)
4" Class 300 ASME B16.5 flat faced4)
DN 50 PN 16 EN 1092-1 Type A flat faced4)
DN 80 PN 16 EN 1092-1 Type A flat faced4)
DN 100 PN 16 EN 1092-1 Type A flat faced4)
DN 50 PN 40 EN 1092-1 Type A flat faced4)
DN 80 PN 40 EN 1092-1 Type A flat faced4)
DN 100 PN 40 EN 1092-1 Type A flat faced4)
50A 10K JIS B 2220 flat faced4)
80A 10K JIS B 2220 flat faced4)
100A 10K JIS B 2220 flat faced4)
DN 50 PN 16 DIN EN 1092-1 Type B1 raised face
DN 80 PN 16 DIN EN 1092-1 Type B1 raised face
DN 100 PN 16 DIN EN 1092-1 Type B1 raised face
DN 150 PN 16 DIN EN 1092-1 Type B1 raised face
DN 50 PN 40 DIN EN 1092-1 Type B1 raised face
DN 80 PN 40 DIN EN 1092-1 Type B1 raised face
DN 100 PN 40 DIN EN 1092-1 Type B1 raised face
DN 150 PN 40 DIN EN 1092-1 Type B1 raised face
4/216
Siemens FI 01 · 2015
0
1
2
3
¢
¢
¢
AA
AB
AC
¢
¢
¢
AD
AE
AF
AG
AH
AJ
¢
¢
¢
BA
BB
BC
¢
¢
¢
CA
CB
CC
DA
DB
DC
¢
¢
¢
EA
EB
EC
FA
FB
FC
GA
GB
GC
GD
HA
HB
HC
HD
JA
JB
JC
JD
JE
JF
DN 50 PN 16 EN 1092-1 Type B1 raised faced4)
DN 80 PN 16 EN 1092-1 Type B1 raised faced4)
DN 100 PN 16 EN 1092-1 Type B1 raised faced4)
DN 50 PN 40 EN 1092-1 Type B1 raised faced4)
DN 80 PN 40 EN 1092-1 Type B1 raised faced4)
DN 100 PN 40 EN 1092-1 Type B1 raised faced4)
KA
KB
KC
KD
KE
KF
50A 10K JIS B 2220 raised faced4)
80A 10K JIS B 2220 raised faced4)
100A 10K JIS B 2220 raised faced4)
DN 50 PN 16 EN 1092-1 Type B1 raised face
DN 80 PN 16 EN 1092-1 Type B1 raised face
DN 100 PN 16 EN 1092-1 Type B1 raised face
LA
LB
LC
MA
MB
MC
DN 150 PN 16 EN 1092-1 Type B1 raised face
DN 50 PN 40 EN 1092-1 Type B1 raised face
DN 80 PN 40 EN 1092-1 Type B1 raised face
DN 100 PN 40 EN 1092-1 Type B1 raised face
DN 150 PN 40 EN 1092-1 Type B1 raised face
Communication/Output
PROFIBUS PA
4 ... 20 mA, HART, start-up at < 3.6 mA
FOUNDATION Fieldbus
Enclosure/Cable inlet
Aluminum, Epoxy painted
2 x ½" NPT
2 x M20x1.5
Antenna
MD
ME
MF
MG
MH
1½" horn
2" horn (fits 2" ASME or DN 50 nozzles)
3" horn (fits 3" ASME or DN 80 nozzles)
4" horn (fits 4" ASME or DN 100 nozzles)
1½" horn with 100 mm extension
2" horn with 100 mm extension
3" horn with 100 mm extension
4" horn with 100 mm extension
Hastelloy C22 (or equivalent)
2" horn (fits 2" ASME or DN 50 nozzles)
3" horn (fits 3" ASME or DN 80 nozzles)
4" horn (fits 4" ASME or DN 100 nozzles)
2" horn (fits 2" ASME or DN 50 nozzles) with
100 mm extension
3" horn (fits 3" ASME or DN 80 nozzles) with
100 mm extension
4" horn (fits 4" ASME or DN 100 nozzles) with
100 mm extension
¢
¢
¢
¢
¢
¢
¢
¢
¢
¢
¢
¢
¢
1
2
3
0
1
A
B
C
D
E
F
G
H
J
K
L
M
N
P
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Horn Antenna
Selection and Ordering data
Article No.
SITRANS LR250 horn antenna
2-wire, 25 GHz pulse radar level transmitter for
continuous monitoring of liquids and slurries in
storage and process vessels including high
temperature and pressure, to a range of 20 m
(66 ft) (antenna dependent). Ideal for small vessels
and low dielectric media.
Approvals
7ML54317 7 7 7 0 - 777 7
General Purpose, CE, CSA, FM, FCC, R&TTE, RCM¢
Intrinsically Safe: CSA/FM Class I, Div. 1, Groups A, ¢
B, C, D, Class II, Div.1, Groups E,F, G, Class III T4
FCC, Industry Canada
Intrinsically Safe: IECEx/ATEX II 1 G Ex ia IIC T4
¢
Ga, IECEx/ATEX II 1D Ex ia ta IIIC T100 °C Da,
o
INMETRO Ex ia IIC T4 Ga, Ex ia ta IIIC T100 C Da,
CE, R&TTE, RCM
Non-incendive: CSA/FM Class I, Div. 2, Groups A, ¢
B, C, D T5, FCC, Industry Canada
Non Sparking: ATEX II 3G Ex nA IIC T4 Gc, CE,
¢
R&TTE, RCM
Increased Safety: IECEx/ATEX II 1/2 GD,1D,
¢
2D Ex e mb ia IIC T4 Ga/Gb, Ex ia ta IIIC T100 °C
Da, INMETRO Ex e ia mb IIC T4 Ga/Gb, Ex ia ta IIIC
T100 oC Da, CE, R&TTE, RCM5)
Flameproof: IECEx/ATEX II 1/2 GD 1D, 2D Ex d mb ¢
ia IIC T4 Ga/Gb, Ex ia ta IIIC T100 °C Da,
INMETRO Ex d ia mb IIC T4 Ga/Gb, Ex ia ta IIIC
T100 oC Da, CE, R&TTE, RCM5)
Explosion proof: CSA/FM Class I, II and III, Div.1, ¢
Groups A, B, C, D, E, F, G, FCC, Industry Canada5)
Non Sparking: NEPSI Ex nA IIC T4 Gc
¢
¢
Intrinsically Safe: NEPSI Ex ia IIC T4 Ga,
Ex iaD 20 T90 IP67 DIP A20 TA90 ºC
¢
Flameproof: NEPSI Ex d ia mb IIC T4 Ga/Gb,
Ex iaD 20 T90 IP67 DIP A20 TA90 ºC5)
Increased Safety: NEPSI Ex e ia mb IIC T4 Ga/Gb, ¢
Ex iaD 20 T90 IP67 DIP A20 TA90 ºC5)
Pressure rating
Rating per Pressure/Temperature curves in manual ¢
0.5 bar g (7.25 psi g) maximum
¢
A
B
C
D
4
E
F
G
H
K
L
M
N
0
1
1)
Available with process connection options AA ... HD & Antenna
Versions A ... H only
2)
Available with process connection options JA ... MH & Antenna
Versions J ... P only
3)
Available For antenna versions A and E only, max. range 10 m (32.8 ft),
dk > 3. Can measure dk >1.6 [20 m (65.6 ft)] when mounted in a stillpipe/
bypass.
4)
Siemens Milltronics type flange (flange bolting patterns and facings
dimensionally correspond to the applicable ASME B16.5, or EN 1092-1,
or JIS B 2220 standard), see operating instructions for details
5)
Applicable with communication option 2 only
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Siemens FI 01 · 2015
4/217
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Horn Antenna
Selection and Ordering data
Order code
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
Plug M12 with mating Connector1)2)3)
¢ A50
Plug 7/8" with mating Connector2)3)4)
¢ A55
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Measuring-point number/identification
(max. 27 characters); specify in plain text
Manufacturer's Test Certificate: M to DIN 55350,
Part 18 and to ISO 9000
¢ C11
Inspection certificate 3.1 of EN 10204
¢ C12
Functional Safety (SIL 2). Device suitable for use in ¢ C20
accordance with IEC 61508 and IEC 615113)5)
4
Namur NE43 compliant, device preset to failsafe
< 3.6 mA5)
Selection and Ordering data
Article No.
Operating Instructions for
FOUNDATION Fieldbus device
¢ N07
English
A5E32221411
German
Note: The Operating Instructions should be
ordered as a separate line item on the order.
A5E32376112
Compact Operating Instructions for
FOUNDATION Fieldbus device
English, French, German, Spanish, Italian, Dutch,
Danish, Finnish, Greek, Portuguese (Portugal),
Swedish
A5E33472700
English, Bulgarian, Czech, Estonian, Hungarian,
Latvian, Lithuanian, Polish, Romanian, Slovakian,
Slovenian
A5E33472738
Operating Instructions for HART/mA device
Article No.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Compact Operating Instructions and Operating Instructions library.
English
A5E32220602
Accessories
German
Note: The Operating Instructions should be
ordered as a separate line item on the order.
A5E32376088
Handheld programmer, Intrinsically safe, EEx ia
7ML1930-1BK
HART modem/USB
(for use with a PC and SIMATIC PDM)
7MF4997-1DB
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F),
HART (two are required)
7ML1930-1AP
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F), PROFIBUS PA
and FOUNDATION Fieldbus (two are required)6)
7ML1930-1AQ
FDA approved FKM o-ring for 2" G (BSPP) process
connections -28 ... +80 °C (-28 ... +176 °F)
7ML1830-3AN
SITRANS RD100, loop powered display see Chapter 7
7ML5741-...
SITRANS RD200, universal input display with
Modbus conversion - see Chapter 7
7ML5740-...
SITRANS RD300, dual line display with totalizer
and linearization curve and Modbus conversion see Chapter 7
7ML5744-...
SITRANS RD500 web, universal remote monitoring
solution for instrumentation - see Chapter 7
7ML5750-...
Compact Operating Instructions for HART/mA
device
English, French, German, Spanish, Italian, Dutch,
Danish, Finnish, Greek, Portuguese (Portugal),
Swedish
A5E33469191
English, Bulgarian, Czech, Estonian, Hungarian,
Latvian, Lithuanian, Polish, Romanian, Slovakian,
Slovenian
A5E33469171
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Compact Operating Instructions and Operating Instructions library.
Operating Instructions for PROFIBUS PA device
English
A5E32221386
German
Note: The Operating Instructions should be
ordered as a separate line item on the order.
A5E32376094
Compact Operating Instructions for
PROFIBUS PA device
For applicable back up point level switch see point level measurement section
English, French, German, Spanish, Italian, Dutch,
Danish, Finnish, Greek, Portuguese (Portugal),
Swedish
A5E33469239
English, Bulgarian, Czech, Estonian, Hungarian,
Latvian, Lithuanian, Polish, Romanian, Slovakian,
Slovenian
A5E33472685
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Compact Operating Instructions and Operating Instructions library.
1)
Available with enclosure option 1 only
2)
To be used with communication options 1 and 3 only.
Connector has IP67 rating.
3)
Available with approval options A and B. Available with approval option C
for use on intrinsically safe applications only. Not rated for dust Ex.
4)
Available with enclosure option 0 only
5)
Applicable to communication option 2 only
6)
For use with communication option 1 and 3 only
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
4/218
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Horn Antenna
■ Characteristic curves
Ambient temperature (°C)
Maximum flange and process temperatures versus allowable ambient temperature
90
130 °C
80
70
65 °C
60
50
40
30
20
4
10
0
0
20
40
60
80
100
120
140
160
180
200
220
Process flange surface temperature (°C)
SITRANS LR250 Ambient/Process Flange Surface Temperature Curve
Siemens FI 01 · 2015
4/219
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Horn Antenna
■ Dimensional drawings
Threaded Horn Antenna
½" NPT cable entry
(or alternatively,
M20 cable gland)
50
(2.0)
Threaded cover
4
167 (6.6)
90 (3.5)
154 (6.1)
159
(6.26)
196 (7.7)
Enclosure/
electronics
Retaining
collar
Sensor reference
point
Process
device tag
28 (1.1)*
Horn
See dimension
table for height to
sensor reference
point
Antenna
O.D.
Antenna
O.D.
*28 mm (1.1) for 1.5 inch and 2 inch, 42 mm (1.65) for 3 inch
Antenna
Type
Height to sensor reference point
Antenna O.D.
Measurement
range
3" threaded
connection
1.5" horn
39.8 (1.57)
1-1/2" threaded
connection
135 (5.3)
N/A
N/A
19 degrees
10 m (32.8 ft)
2" horn
47.8 (1.88)
N/A
166 (6.55)
180 (7.09)
15 degrees
20 m (65.6 ft)
3" horn
74.8 (2.94)
N/A
199 (7.85)
213 (8.39)
10 degrees
20 m (65.6 ft)
4" horn
94.8 (3.73)
N/A
254 (10)
268 (10.55)
8 degrees
20 m (65.6 ft)
SITRANS LR250 Threaded Horn Antenna, dimensions in mm (inch)
4/220
2" threaded
connection
Beam angle
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Horn Antenna
Threaded Horn Antenna with Extension
50
(2.0)
½" NPT cable entry
(or alternatively,
M20 cable gland)
Threaded cover
167
(6.6)
154 (6.1)
4
90 (3.5)
Enclosure/
electronics
159
(6.26)
196
(7.7)
Retaining
collar
28 (1.1)*
Sensor reference
point
Process
device tag
Horn
See dimension
table for height to
sensor reference
point
Antenna
O.D.
Antenna
O.D.
*28 mm (1.1) for 1.5 inch and 2 inch, 42 mm (1.65) for 3 inch
Antenna
Type
Height to sensor reference point
Antenna O.D.
1-1/2" threaded
connection
2" threaded
connection
Beam angle
Measurement
range
3" threaded
connection
1.5" horn
139.8 (5.57)
235 (9.3)
N/A
N/A
19 degrees
10 m (32.8 ft)
2" horn
147.8 (5.88)
N/A
266 (10.55)
280 (11.09)
15 degrees
20 m (65.6 ft)
3" horn
174.8 (6.94)
N/A
299 (11.85)
313 (12.39)
10 degrees
20 m (65.6 ft)
4" horn
194.8 (7.73)
N/A
354 (14)
368 (14.55)
8 degrees
20 m (65.6 ft)
SITRANS LR250 Threaded Horn Antenna with Extension, dimensions in mm (inch)
Siemens FI 01 · 2015
4/221
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Horn Antenna
Flanged Horn
50
(2.0)
½" NPT cable entry
(or alternatively,
M20 cable gland)
Threaded cover
167
(6.6)
4
154
(6.1)
90
(3.5)
Enclosure/
electronics
227 (8.94)
Name-plate
Retaining collar
190
(7.48)
Flange
horn
135.3 168.3 223.3
5.32
6.62 8.79
Process
connection tag
50 (2) nominal
80 (3) nominal
100 (4) nominal
horn
O.D.
Nominal Horn
Size
Horn O.D.
Height to sensor reference point
Stainless steel
Optional alloy flange
flange raised or
flat-faced
135.3 (5.32)
138.3 (5.44)
Measurement
range
50 (2)
47.8 (1.88)
19 degrees
10 m (32.8 ft)
80 (3)
74.8 (2.94)
168.3 (6.62)
171.3 (6.74)
15 degrees
20 m (65.6 ft)
100 (4)
94.8 (3.73)
223.3 (8.79)
226.3 (8.90)
10 degrees
20 m (65.6 ft)
SITRANS LR250 Flanged Horn Antenna, dimensions in mm (inch)
4/222
Beam angle
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Horn Antenna
Flanged Horn with Extension
50
(2.0)
½" NPT cable entry
(or alternatively,
M20 cable gland)
Threaded cover
167
(6.6)
154
(6.1)
4
90
(3.5)
enclosure/
electronics
227 (8.94)
name-plate
retaining collar
190
(7.48)
flange
process
connection tag
235.3
(9.32) 268.3
(10.62)
horn
323.3
(12.79)
50 (2) nominal
80 (3) nominal
100 (4) nominal
Horn O.D.
Nominal Horn
Size
Horn O.D.
Height to sensor reference point
Stainless steel
Optional alloy flange
flange raised or
flat-faced
235.3 (9.32)
238.3 (9.44)
Beam angle
Measurement
range
50 (2)
47.8 (1.88)
19 degrees
10 m (32.8 ft)
80 (3)
74.8 (2.94)
268.3 (10.62)
271.3 (10.74)
15 degrees
20 m (65.6 ft)
100 (4)
94.8 (3.73)
323.3 (12.79)
326.3 (12.90)
10 degrees
20 m (65.6 ft)
SITRANS LR250 Flanged Horn Antenna with Extension, dimensions in mm (inch)
Siemens FI 01 · 2015
4/223
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Horn Antenna
■ Schematics
Connect the wires to the
terminals as shown: the
polarity is identified on the
terminal block.
4
Gland
Hand Programmer
Shield for HART,
PROFIBUS PA , and
FOUNDATION Fieldbus
Intrinsically Safe
versions only.
Part number:
7ML1930-1BK
Notes:
1. DC terminal shall be supplied from a source providing electrical isolation between the input and output, to meet the applicable
safety requirements of IEC 61010-1.
2. All field wiring must have insulation suitable for rated input voltages.
3. Use shielded twisted pair cable (14 ... 22 AWG) for HART version.
4. Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes.
SITRANS LR250 connections
4/224
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Specials
■ Selection and ordering data
SITRANS LR250 Specials
SITRANS LR250 Specials
Article No.
Article No.
SITRANS LR250 horn version enclosures
(< 3.6 mA start-up HART)
SITRANS LR250 horn version enclosures
(PROFIBUS PA models)
LR250 horn version enclosure with board stack,
NPT cable inlet, approval option A,
with PROFIBUS PA communication,
no process connection
A5E01156836
SITRANS LR250 horn version enclosure with
board stack, M20 cable inlet, approval option A,
with HART communication start-up at < 3.6 mA,
no process connection
A5E02956317
LR250 horn version enclosure with board stack,
M20 cable inlet, approval option A,
with PROFIBUS PA communication,
no process connection
A5E01156838
SITRANS LR250 horn version enclosure with
board stack, M20 cable inlet, approval option C,
with HART communication start-up at < 3.6 mA,
no process connection
A5E02956319
LR250 horn version enclosure with board stack,
NPT cable inlet, approval option B,
with PROFIBUS PA communication,
no process connection
A5E01156839
SITRANS LR250 horn version enclosure with
board stack, M20 cable inlet, approval option E,
with HART communication start-up at < 3.6 mA,
no process connection
A5E02956320
LR250 horn version enclosure with board stack,
M20 cable inlet, approval option B,
with PROFIBUS PA communication,
no process connection
A5E01156841
SITRANS LR250 horn version enclosure with
board stack, M20 cable inlet, approval option F,
with HART communication start-up at < 3.6 mA,
no process connection
A5E02956322
LR250 horn version enclosure with board stack,
NPT cable inlet, approval option C,
with PROFIBUS PA communication,
no process connection
A5E01156843
A5E02956323
LR250 horn version enclosure with board stack,
M20 cable inlet, approval option C,
with PROFIBUS PA communication,
no process connection
A5E01156844
SITRANS LR250 horn version enclosure with
board stack, M20 cable inlet, approval option G,
with HART communication start-up at < 3.6 mA,
no process connection
A5E03441096
LR250 horn version enclosure with board stack,
M20 cable inlet, approval option C,
with PROFIBUS PA communication,
no process connection
A5E01156846
LR250 horn version enclosure with board stack,
NPT cable inlet, approval option A, with HART
communication start-up at < 3.6 mA, no process
connection
A5E03441097
LR250 horn version enclosure with board stack,
M20 cable inlet, approval option D,
with PROFIBUS PA communication,
no process connection
A5E01156848
LR250 horn version enclosure with board stack,
NPT cable inlet, approval option B, with HART
communication start-up at < 3.6 mA, no process
connection
A5E03441098
LR250 enclosure with board stack, NPT cable
inlet, approval option B,
with FOUNDATION FIELDBUS communication,
no process connection
A5E03769538
LR250 horn version enclosure with board stack,
NPT cable inlet, approval option D, with HART
communication start-up at < 3.6 mA, no process
connection
A5E03441099
LR250 enclosure with board stack, NPT cable
inlet, approval option D,
with FOUNDATION FIELDBUS communication,
no process connection
A5E03769539
LR250 horn version enclosure with board stack,
NPT cable inlet, approval option H, with HART
communication start-up at < 3.6 mA, no process
connection
LR250 enclosure with board stack, M20 cable
inlet, approval option E,
with FOUNDATION FIELDBUS communication,
no process connection
A5E03769543
4
SITRANS LR250 horn antenna and
extension kits
SITRANS LR250 horn version enclosures
(FOUNDATION Fieldbus models)
LR250 horn version enclosure with board stack,
M20 cable inlet, approval option C,
with FOUNDATION Fieldbus communication,
no process connection
A5E02654608
LR250 horn version enclosure with board stack,
NPT cable inlet, approval option A,
with FOUNDATION Fieldbus communication,
no process connection
A5E02653792
LR250 horn version enclosure with board stack,
M20 cable inlet, approval option A,
with FOUNDATION Fieldbus communication,
no process connection
A5E02653793
LR250 horn version enclosure with board stack,
NPT cable inlet, approval option C,
with FOUNDATION Fieldbus communication,
no process connection
A5E02654606
38 mm (1.5 inch) horn antenna kit,
1.5" Process Connections only
A5E01151539
100 mm (4 inch) horn antenna extension kit,
1.5" Process Connections only
A5E01151553
50 mm (2 inch) stainless steel 316L horn antenna kit
A5E01151569
75 mm (3 inch) stainless steel 316L horn antenna kit
A5E01151571
100 mm (4 inch) stainless steel 316L horn antenna kit A5E01151573
100 mm (4 inch) horn antenna extension kit,
50 mm (2 inch), 75 mm (3 inch) and 100 mm
(4 inch) process connection
A5E01151577
50 mm (2 inch) horn antenna kit, Hastelloy C-22
A5E01151584
75 mm (3 inch) horn antenna kit, Hastelloy C-22
A5E01151585
100 mm (4 inch) horn antenna kit, Hastelloy C-22
A5E01151587
5 Dupont 1Gr Polyback, PTFE grease kit
A5E01151626
LR250 lid with O-ring
A5E02465410
Siemens FI 01 · 2015
4/225
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 threaded PVDF antenna
■ Overview
■ Benefits
4
SITRANS LR250 with threaded PVDF antenna is a 2-wire,
25 GHz pulse radar level transmitter for continuous monitoring of
liquids and slurries in storage and process vessels including
corrosives or aggressive materials, to a range of 10 m (32.8 ft) or
20 m (66 ft) when used in a stilling pipe.
• Fully insulated PVDF antenna design for use in chemical and
sanitary environments where aggressive and corrosive
materials are used
• Cost effective replacement for transmitters made of exotic
materials
• Graphical local user interface (LUI) makes operation simple
with plug-and-play setup using the intuitive Quick Start Wizard
• LUI displays echo profiles for diagnostic support
• 25 GHz high frequency and 50 mm (2 inch) process
connection/antenna allow for easy mounting in nozzles
• Insensitive to mounting location and obstructions, and less
sensitive to nozzle interference
• Short blanking distance for improved minimum measuring
range to 50 mm (2 inch) from the end of the antenna
• Communication using HART or PROFIBUS PA,
or FOUNDATION Fieldbus
• Process Intelligence signal processing for improved
measurement reliability and Auto False-Echo Suppression of
fixed obstructions
• Programming using infrared Intrinsically Safe handheld
programmer or over a network using SIMATIC PDM,
Emerson AMS, or Field Device Tools, such as PACTware or
Fieldcare via SITRANS DTM.
• Suitable for use in Safety Related Systems in accordance with
IEC 61508/61511 (SIL-2)
• 3 mm (0.118 inch) accuracy in accordance with IEC 60770-1
■ Application
SITRANS LR250 includes a graphical local user interface (LUI)
that improves setup and operation by including an intuitive
Quick Start Wizard, and echo profile displays for diagnostic support. Start-up is easy using the Quick Start wizard with a few
parameters required for basic operation.
The 25 GHz frequency creates a narrow, focused beam allowing
for smaller antenna options and decreasing sensitivity to
obstructions.
SITRANS LR250’s unique design allows safe and simple programming using the Intrinsically Safe handheld programmer
without having to open the instrument’s lid.
SITRANS LR250 measures superbly in small vessels and in
tanks/vessels up to 10 m (32 ft) on materials with dk > 3 or 20 m
(66 ft) when used in a stilling pipe with dk  1.6.
• Key Applications: liquid bulk storage tanks, process vessels
with agitators, vaporous liquids, temperatures to 80 °C
(176 °F), corrosive and aggressive materials and applications
requiring functional safety
4/226
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 threaded PVDF antenna
■ Configuration
Installation
Note:
• Beam angle is the width of the
cone where the energy density
is half of the peak energy
density.
• The peak energy density is
directly in front of and in line
with the antenna.
• There is a signal transmitted
outside of the beam angle;
therefore false targets may be
detected.
Mounting unit on bypass
Orient front or back of
device toward vent.
4
Mounting unit on
stilling well
Orient front or back of device
toward stillpipe slots.
Mounting on a nozzle
min. 10 (0.4)
Mounting unit on vessel
19°
”•UG\WGOYP
SITRANS LR250 PVDF antenna installation, dimensions in mm (inch)
Siemens FI 01 · 2015
4/227
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 threaded PVDF antenna
■ Technical specifications
Mode of operation
Radar level measurement
Frequency
K-band (25.0 GHz)
Minimum measuring range
50 mm (2 inch) from end of antenna
Maximum measuring range
10 m (32.8 ft) or 20 m (66 ft) when
used in a stilling pipe with dk  1.6
Output
HART
• Analog output
• Accuracy
• Fail-safe
4
Power supply
Measuring principle
PROFIBUS PA
• Function blocks
FOUNDATION Fieldbus
• Functionality
• Version
• Function blocks
Performance (according to
reference conditions IEC60770-1)
Maximum measured error
Influence of ambient temperature
Version 5.1
4 ... 20 mA
± 0.02 mA
• Programmable as high low or
hold (loss of echo)
• NE 43 programmable
Profile 3.1
2 Analog Input (AI)
H1
Basic or LAS
ITK 5.2.0
2 Analog Input (AI)
• > 500 mm from sensor reference
point: 3 mm (0.118 inch)
• < 500 mm from sensor reference
point: 25 mm (1 inch)
< 0.003 %/K
Rated operating conditions
Installation conditions
Location
4 ... 20 mA/HART
Nominal 24 V DC (max. 30 V DC)
with max. 550 
PROFIBUS PA
• 15 mA
• per IEC 61158-2
FOUNDATION Fieldbus
• 20.0 mA
• per IEC 61158-2
Certificates and approvals
General
CSAUS/C, CE, FM, NE 21, RCM
Radio
FCC, Industry Canada and
Europe ETSI EN 302-372, RCM
Hazardous
• Explosion Proof (Brazil)
• Increased Safety (Brazil)
• Intrinsically Safe (Brazil)
• Explosion Proof (Canada/USA)
• Intrinsically Safe (Canada/USA)
• Non-incendive (Canada/USA)
• Flame Proof/Increased Safety
(China)
• Intrinsically Safe (China)
Indoor/outdoor
• Non-sparking (China)
• Intrinsically Safe (Europe)
Ambient conditions (enclosure)
Ambient temperature
-40 ... +80 °C (-40 ... +176 °F)
Installation category
I
Pollution degree
4
• Non-sparking/Energy Limited
(Europe)
• Flame Proof (International/Europe)
Medium conditions
Dielectric constant r
 3 (1.6 in stillpipe)
Process temperature
-40 ... +80 °C (-40 ... +176 °F) at
process connection (Is suitable for
CIP at 120 °C for 1/2 hr max.)
Process pressure
Up to 5 bar g (72 psi g) temperature
dependent.
See Pressure/Temperature curves for
more information
Design
Enclosure
• Material
• Cable inlet
Degree of protection
Weight
Display (local)
Antenna
• Material
• Dimensions (nominal sizes)
Process connections
Process connection
Aluminum, polyester powder-coated
2 x M20x1.5 or 2 x ½" NPT
Type 4X/NEMA 4X, Type 6/
NEMA 6, IP67, IP68
approximately 3.3 kg (7.27 lb)
Graphic local user interface
including quick start wizard and
echo profile display
• Increased Safety
(International/Europe)
• Intrinsically Safe (International)
•
•
•
•
Explosion Proof (Russia)
Increased Safety (Russia)
Intrinsically Safe (Russia)
Marine
Functional Safety
Programming
Intrinsically Safe Siemens handheld
programmer
• Approvals for handheld
programmer
PVDF (Polyvinylidene fluoride)
2 inch (48 mm)
2" NPT [(Taper), ASME B1.20.1]
2" [(BSPT), EN 10226]
2" [(BSPP), EN ISO 228-1]
Handheld communicator
PC
Display (local)
4/228
Siemens FI 01 · 2015
INMETRO Ex d ia mb IIC T4 Ga/Gb,
Ex ia ta IIIC T100 °C Da
INMETRO Ex e ia mb IIC T4 Ga/Gb,
Ex ia ta IIIC T100 °C Da
INMETRO Ex ia IIC T4 Ga, Ex ia ta
IIIC T100 °C Da
CSA/FM Class I, Div. 1,
Groups A, B, C, D; Class II, Div. 1,
Groups E, F, G; Class III T4
CSA/FM Class I, Div. 1,
Groups A, B, C, D; Class II, Div. 1,
Groups E, F, G; Class III T4
CSA/FM Class I, Div. 2,
Groups A, B, C, D T5
Ex d ia mb IIC T4 Ga/Gb, Ex e ia mb
IIC T4 Ga/Gb, Ex iaD 20 T90 IP67 DIP
A20 TA90 ºC
Ex ia IIC T4 Ga, Ex iaD 20 T90 IP67
DIP A20 TA90 ºC
NEPSI Ex nA IIC T4 Gc
ATEX II 1G Ex ia IIC T4 Ga
ATEX II 1D Ex ia ta IIC T100 °C Da
ATEX II 3G Ex nA IIC T4 Gc
IECEx/ATEX II 1/2 GD, 1D, 2D,
Ex d mb ia IIC T4 Ga/Gb, Ex ia ta IIC
T100 °C Da
IECEx/ATEX II 1/2 GD, 1D, 2D,
Ex e mb ia IIC T4 Ga/Gb, Ex ia ta IIIC
T100 °C Da
IECEx/ATEX II 1 G Ex ia IIC T4 Ga,
IECEX/ATEX II 1D Ex ia ta IIC T100 °C
Da
GOST-R Ex d
GOST-R Ex e
GOST-R Ex ia
• Lloyd's Register of Shipping
• ABS Type Approval
• Bureau Veritas
SIL-2 suitable in accordance with
IEC 61508/61511
Infrared receiver
IS model:
ATEX II 1 GD Ex ia IIC T4 Ga
Ex ia D 20 T135°C Ta = -20 ... +50 °C
CSA/FM Class I, II, III, Div. 1,
Groups A, B, C, D, E, F, G, T6
Ta = +50 °C
IECEx SIR 09.0073
HART communicator 375/475
• SIMATIC PDM
• Emerson AMS
• SITRANS DTM (for connection into
FDT, such as PACTware or
Fieldcare)
Graphic local user interface including
quick start wizard and echo profile
displays
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 threaded PVDF antenna
Selection and Ordering data
Article No.
Selection and Ordering data
SITRANS LR250 threaded PVDF antenna
2-wire, 25 GHz pulse radar level transmitter for
continuous monitoring of liquids and slurries in
storage and process vessels including corrosives
or aggressive materials, to a range of 10 m (32.8 ft)
or 20m (66ft) when used in a stilling pipe.
7ML543177 7 7 0 - 77 77
Further designs
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Process Connection and Antenna Material
Threaded PVDF antenna
Process Connection Type
Threaded connections PVDF
2" NPT (ASME B1.20.1) (tapered thread)
R 2" [(BSPT), EN 10226-1] (tapered thread)
G 2" [(BSPP), EN ISO 228-1] (parallel thread)
Communication/Output
PROFIBUS PA
4 ... 20 mA, HART, start-up at < 3.6 mA
FOUNDATION Fieldbus
Enclosure/Cable inlet
Aluminum, Epoxy painted
2 x ½" NPT
2 x M20x1.5
Antenna
2 inch(50 mm) threaded PVDF antenna
Approvals
¢
¢
¢
¢
¢
¢
Please add "-Z" to Article No. and specify Order
code(s).
Plug M12 with mating Connector1)2)3)
¢ A50
Plug 7/8" with mating Connector2)3)4)
¢ A55
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Measuring-point number/identification
(max. 27 characters); specify in plain text
¢ 4
¢
¢
¢
Order code
PA
PB
PC
1
2
3
0
1
R
Manufacturer's test certificate: M to DIN 55350,
Part 18 and to ISO 9000
¢ C11
Inspection Certificate Type 3.1 per EN 10204
¢ C12
Functional Safety (SIL 2). Device suitable for use
in accordance with IEC 61508 and IEC 615115)6)
¢ C20
Namur NE43 compliant, device preset to failsafe
< 3.6 mA5)
¢ N07
Operating Instructions for HART/mA device
Article No.
English
A5E32220602
German
Note: The Operating Instructions should be ordered as a separate line item on the order.
A5E32376088
Compact Operating Instructions for HART/mA
device
General Purpose, CE, CSA, FM, FCC, R&TTE, RCM¢
Intrinsically Safe: CSA/FM Class I, Div. 1, Groups A, ¢
B, C, D, Class II, Div.1, Groups E ,F, G, Class III T4
FCC, Industry Canada
Intrinsically Safe: IECEx/ATEX II 1 G Ex ia IIC T4 Ga, ¢
IECEx/ATEX II 1D Ex ia ta IIIC T100 °C Da,
INMETRO Ex ia IIC T4 Ga, Ex ia ta IIIC T100 oC Da,
CE, R&TTE, RCM
A
B
English, French, German, Spanish, Italian, Dutch,
Danish, Finnish, Greek, Portuguese (Portugal),
Swedish
A5E33469191
A5E33469171
C
English, Bulgarian, Czech, Estonian, Hungarian,
Latvian, Lithuanian, Polish, Romanian, Slovakian,
Slovenian
Non-incendive: CSA/FM Class I, Div. 2, Groups A, ¢
B, C, D T5, FCC, Industry Canada
D
¢
E
Non Sparking: ATEX II 3G Ex nA IIC T4 Gc, CE,
R&TTE, RCM
¢
Increased Safety: IECEx/ATEX II 1/2 GD,1D,
2D Ex e mb ia IIC T4 Ga/Gb, Ex ia ta IIIC T100 °C
Da, INMETRO Ex e ia mb IIC T4 Ga/Gb, Ex ia ta IIIC
T100 oC Da, CE, R&TTE, RCM1)
Flameproof: IECEx/ATEX II 1/2 GD 1D, 2D Ex d mb ¢
ia IIC T4 Ga/Gb, Ex ia ta IIIC T100 °C Da,
INMETRO Ex d ia mb IIC T4 Ga/Gb, Ex ia ta IIIC
T100 oC Da, CE, R&TTE, RCM1)
Explosion proof: CSA/FM Class I, II and III, Div.1, ¢
Groups A, B, C, D, E, F, G, FCC, Industry Canada1)
Non Sparking: NEPSI Ex nA IIC T4 Gc
¢
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Compact Operating Instructions and Operating Instructions library.
Operating Instructions for PROFIBUS PA device
F
English
A5E32221386
German
Note: The Operating Instructions should be ordered as a separate line item on the order.
A5E32376094
Compact Operating Instructions for
PROFIBUS PA device
G
H
K
English, French, German, Spanish, Italian, Dutch,
Danish, Finnish, Greek, Portuguese (Portugal),
Swedish
A5E33469239
English, Bulgarian, Czech, Estonian, Hungarian,
Latvian, Lithuanian, Polish, Romanian, Slovakian,
Slovenian
A5E33472685
Intrinsically Safe: NEPSI Ex ia IIC T4 Ga, Ex iaD 20 ¢
T90 IP67 DIP A20 TA90 ºC
L
¢
M
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Compact Operating Instructions and Operating Instructions library.
Increased Safety: NEPSI Ex e ia mb IIC T4 Ga/Gb, ¢
Ex iaD 20 T90 IP67 DIP A20 TA90 ºC1)
N
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Flameproof: NEPSI Ex d ia mb IIC T4 Ga/Gb,
Ex iaD 20 T90 IP67 DIP A20 TA90 ºC1)
Pressure rating
Rating per Pressure/Temperature curves in manual ¢
1)
2
Applicable to Communication option 2 only
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Siemens FI 01 · 2015
4/229
4
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 threaded PVDF antenna
Article No.
Selection and Ordering data
Selection and Ordering data
Operating Instructions for
FOUNDATION Fieldbus device
English
A5E32221411
German
Note: The Operating Instructions should be ordered as a separate line item on the order.
A5E32376112
Compact Operating Instructions for
FOUNDATION Fieldbus device
English, French, German, Spanish, Italian, Dutch,
Danish, Finnish, Greek, Portuguese (Portugal),
Swedish
A5E33472700
English, Bulgarian, Czech, Estonian, Hungarian,
Latvian, Lithuanian, Polish, Romanian, Slovakian,
Slovenian
A5E33472738
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Compact Operating Instructions and Operating Instructions library.
Handheld programmer, Intrinsically safe, EEx ia
7ML1930-1BK
HART modem/USB
(for use with a PC and SIMATIC PDM)
7MF4997-1DB
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F), HART
7ML1930-1AP
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F),
PROFIBUS PA and FOUNDATION Fieldbus2)
7ML1930-1AQ
FDA approved FKM o-ring for 2" G (BSPP) process
connections -28 ... +80 °C (-28 ... +176 °F)
7ML1830-3AN
SITRANS RD100, loop powered display see Chapter 7
7ML5741-...
SITRANS RD200, universal input display with
Modbus conversion - see Chapter 7
7ML5740-...
SITRANS RD300, dual line display with totalizer
and linearization curve and Modbus conversion see Chapter 7
7ML5744-...
SITRANS RD500 web, universal remote monitoring
solution for instrumentation - see Chapter 7
7ML5750-...
For applicable back up point level switch see point level measurement section
1)
Available with Enclosure option 1 only
2)
To be used with Communication options 1 and 3 only.
Connector has IP67 rating.
3)
Available with Approval options A and B. Available with approval option C
for use on intrinsically safe applications only. Not rated for dust Ex.
4)
Available with Enclosure option 0 only
5)
Available with communication option 2 only
6)
Available with approval options A ... E only
■ Characteristic curves
Pressure/Temperature Curve
Pressure (bar, gauge)
4
Article No.
Accessories
20 ºC,
5 bar
5
4.5
4
3.5
3
2.5
80 ºC,
2.25 bar
2
1.5
1
0.5
0
-0.5
-1
-60
-40
-20
0
20
40
60
80
100
Temperature (°C)
SITRANS LR250 PVDF antenna pressure/temperature curve
4/230
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 threaded PVDF antenna
■ Dimensional drawings
50
(2.0)
1/2" NPT cable entry (or
alternatively, M20 cable gland)
Threaded cover
167
(6.6)
154
(6.1)
4
90
(3.5)
Enclosure/
electronics
184
(7.24)
Process
connection tag
146
(5.74)
Sensor reference
point
121
(4.76)
2" thread
Threaded PVDF
antenna
49.5
(1.94)
antenna O.D.
SITRANS LR250 PVDF antenna, dimensions in mm (inch)
■ Schematics
Connect the wires to the
terminals as shown: the
polarity is identified on the
terminal block.
Gland
Hand Programmer
Shield for HART,
PROFIBUS PA , and
FOUNDATION Fieldbus
Intrinsically Safe
versions only.
Part number:
7ML1930-1BK
Notes:
1. DC terminal shall be supplied from a source providing electrical isolation between the input and output, to meet the applicable
safety requirements of IEC 61010-1.
2. All field wiring must have insulation suitable for rated input voltages.
3. Use shielded twisted pair cable (14 ... 22 AWG) for HART version.
4. Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes.
SITRANS LR250 connections
Siemens FI 01 · 2015
4/231
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 threaded PVDF Specials
■ Selection and ordering data
SITRANS LR250 threaded PVDF Specials
SITRANS LR250 threaded PVDF Specials
Article No.
SITRANS LR250 threaded PVDF
antenna version enclosures
(PROFIBUS PA models)
4
Article No.
SITRANS LR250 threaded PVDF
antenna version enclosures
(< 3.6 mA start-up HART models)
LR250 threaded PVDF antenna version
enclosure with board stack, M20 cable inlet,
approval option A, with PROFIBUS PA
communication, no process connection
A5E03588171
LR250 enclosure with board stack,
M20 cable inlet, approval option A,
with HART communication start-up
at < 3.6 mA, no process connection
A5E03569747
LR250 threaded PVDF antenna version
enclosure with board stack, NPT cable inlet,
approval option A, with PROFIBUS PA
communication, no process connection
A5E03588253
LR250 enclosure with board stack,
NPT cable inlet, approval option A,
with HART communication start-up
at < 3.6 mA, no process connection
A5E03586807
LR250 threaded PVDF antenna version
enclosure with board stack, NPT cable inlet,
approval option B, with PROFIBUS PA
communication, no process connection
A5E03588512
LR250 enclosure with board stack,
NPT cable inlet, approval option B,
with HART communication start-up
at < 3.6 mA, no process connection
A5E03586854
LR250 threaded PVDF antenna version
enclosure with board stack, M20 cable inlet,
approval option C, with PROFIBUS PA
communication, no process connection
A5E03589260
LR250 enclosure with board stack,
M20 cable inlet, approval option C,
with HART communication start-up
at < 3.6 mA, no process connection
A5E03586887
LR250 threaded PVDF antenna version
enclosure with board stack, NPT cable inlet,
approval option D, with PROFIBUS PA
communication, no process connection
A5E03589262
LR250 enclosure with board stack,
NPT cable inlet, approval option D,
with HART communication start-up
at < 3.6 mA, no process connection
A5E03586961
LR250 threaded PVDF antenna version
enclosure with board stack, M20 cable inlet,
approval option E, with PROFIBUS PA
communication, no process connection
A5E03589264
LR250 enclosure with board stack,
M20 cable inlet, approval option E,
with HART communication start-up
at < 3.6 mA, no process connection
A5E03587012
LR250 enclosure with board stack,
M20 cable inlet, approval option F,
with HART communication start-up
at < 3.6 mA, no process connection
A5E03587132
LR250 enclosure with board stack,
M20 cable inlet, approval option G,
with HART communication start-up
at < 3.6 mA, no process connection
A5E03587223
LR250 enclosure with board stack,
NPT cable inlet, approval option H,
with HART communication start-up
at < 3.6 mA, no process connection
A5E03588125
SITRANS LR250 threaded PVDF
antenna version enclosures
(FOUNDATION Fieldbus models)
LR250 enclosure with board stack,
M20 cable inlet, approval option A,
with FOUNDATION Fieldbus communication,
no process connection
A5E03589266
LR250 enclosure with board stack,
NPT cable inlet, approval option A,
with FOUNDATION Fieldbus communication,
no process connection
A5E03589275
LR250 enclosure with board stack,
NPT cable inlet, approval option B,
with FOUNDATION Fieldbus communication,
no process connection
A5E03589277
LR250 enclosure with board stack,
M20 cable inlet, approval option C,
with FOUNDATION Fieldbus communication,
no process connection
A5E03589280
LR250 enclosure with board stack,
NPT cable inlet, approval option D,
with FOUNDATION Fieldbus communication,
no process connection
A5E03589281
LR250 enclosure with board stack,
M20 cable inlet, approval option E,
with FOUNDATION Fieldbus communication,
no process connection
A5E03589283
4/232
Siemens FI 01 · 2015
SITRANS LR250 threaded PVDF
antenna kits
Antenna kit 2" NPT threaded PVDF
A5E03528941
Antenna kit 2" R (BSPT) threaded PVDF
A5E03528943
Antenna kit 2" G (BSPP) threaded PVDF
A5E03528947
Kit of hardware parts for LR250 threaded PVDF
antenna: consists of O-rings, screws,
wavewasher and loctite
A5E03528948
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Flanged Encapsulated Antenna
■ Overview
SITRANS LR250 measures superbly in small vessels and in
tanks/vessels up to 20 m (66 ft) on materials with dk > 1.6.
• Key Applications: liquid bulk storage tanks, process vessels
with agitators, vaporous liquids, temperatures to 170 °C
(338 °F), corrosive and aggressive materials and applications
where ease of cleaning is required, such as food or fine
chemicals.
■ Configuration
Installation
SITRANS LR250 with flanged encapsulated antenna is a 2-wire,
25 GHz pulse radar level transmitter for continuous monitoring of
liquids and slurries in storage and process vessels including
corrosives or aggressive materials, to a range of 20 m (66 ft)
(antenna dependent).
Note:
• Beam angle is the width of the
cone where the energy density
is half of the peak energy
density.
• The peak energy density is
directly in front of and in line
with the antenna.
• There is a signal transmitted
outside of the beam angle;
therefore false targets may be
detected.
4
3"/DN 80/80A
or larger
9.6°
2"/DN 50
/50A
12.8°
■ Benefits
Mounting unit on bypass
Orient front or back of
device toward vent.
Mounting unit on vessel
Mounting unit on
stilling well
Orient front or back of device
toward stillpipe slots.
Mounting on a nozzle
Max. 500 (20)
• Fully encapsulated horn antenna design with FDA approved
TFM 1600 PTFE lens for use in chemical and sanitary environments where aggressive and corrosive materials are used
• Cost effective replacement for transmitters made of exotic
materials
• Graphical local user interface (LUI) makes operation simple
with plug-and-play setup using the intuitive Quick Start Wizard
• LUI displays echo profiles for diagnostic support
• 25 GHz high frequency and 50 mm (2 inch) process
connection/antenna allow for easy mounting
• Insensitive to mounting location and obstructions, and less
sensitive to nozzle interference
• Short blanking distance for improved minimum measuring
range to 50 mm (2 inch) from the end of the antenna
• Communication using HART, PROFIBUS PA,
or FOUNDATION Fieldbus
• Process Intelligence signal processing for improved
measurement reliability and Auto False-Echo Suppression of
fixed obstructions
• Programming using infrared Intrinsically Safe handheld
programmer or over a network using SIMATIC PDM, Emerson
AMS, or Field Device Tools, such as PACTware or Fieldcare via
SITRANS DTM
• Functional Safety (SIL 2). Device suitable for use in accordance with IEC 61508 and IEC 61511
■ Application
SITRANS LR250 includes a graphical local user interface (LUI)
that improves setup and operation by including an intuitive
Quick Start Wizard, and echo profile displays for diagnostic support. Start-up is easy using Quick Start Wizard with a few parameters required for basic operation.
The 25 GHz frequency creates a narrow, focused beam allowing
for smaller antenna options and decreasing sensitivity to
obstructions.
SITRANS LR250's unique design allows safe and simple programming using the Intrinsically Safe handheld programmer
without having to open the instrument's lid.
t•UG\WGOYP
SITRANS LR250 flanged encapsulated antenna installation,
dimensions in mm (inch)
Siemens FI 01 · 2015
4/233
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Flanged Encapsulated Antenna
■ Technical specifications
Mode of operation
Radar level measurement
Frequency
K-band (25.0 GHz)
Minimum measuring range
50 mm (2 inch) from end of antenna
Maximum measuring range
20 m (66 ft)
Output
HART
• Analog output
• Accuracy
• Fail-safe
4
Process connections
Measuring principle
PROFIBUS PA
• Function blocks
FOUNDATION Fieldbus
• Functionality
• Version
• Function blocks
Version 5.1
4 ... 20 mA
± 0.02 mA
• Programmable as high low or hold
(loss of echo)
• NE 43 programmable
Profile 3.01
2 Analog Input (AI)
H1
Basic or LAS
ITK 5.2.0
2 Analog Input (AI)
Performance (according to reference conditions IEC60770-1)
Maximum measured error
Influence of ambient temperature
• > 500 mm from sensor reference
point: 3 mm (0.118 inch)
• < 500 mm from sensor reference
point: 25 mm (1 inch)
< 0.003 %/K
Rated operating conditions
Flanged connection
• 2, 3, 4, 6" Class 150 ASME B16.5
• 50A, 80A, 100A, 150A 10K JIS B
2220
• DN 50, DN 80, DN 100 &
DN 150 PN 10/16 EN 1092-1
type B1
Power supply
4 ... 20 mA/HART
Nominal 24 V DC (max. 30 V DC)
with max. 550 
PROFIBUS PA
• 15 mA
• Per IEC 61158-2
FOUNDATION Fieldbus
• 20.0 mA
• Per IEC 61158-2
Certificates and approvals
General
CSAUS/C, CE, FM, NE 21, RCM
Radio
FCC, Industry Canada and
Europe ETSI EN 302-372, RCM
Hazardous
• Explosion Proof (Brazil)
• Increased Safety (Brazil)
• Intrinsically Safe (Brazil)
• Explosion Proof (Canada/USA)
Installation conditions
Location
Indoor/outdoor
• Intrinsically Safe (Canada/USA)
Ambient temperature
-40 ... +80 °C (-40 ... +176 °F)
• Non-incendive (Canada/USA)
Installation category
I
Pollution degree
4
Ambient conditions (enclosure)
Medium conditions
Dielectric constant r
 1.6 (antenna dependent)
Process temperature
-40 ... +170 °C (-40 ... +338 °F) at
process connection
Process pressure
See Pressure/Temperature curves for
more information (page 4/237)
Design
Aluminum, polyester powder-coated
2 x M20x1.5 or 2 x ½" NPT
Degree of protection
Type 4X/NEMA 4X, Type 6/NEMA 6,
IP67, IP68
Weight (dependent on process connection)
• Approx. 7 kg (15.43 lb) for
2" Class 150 ASME B16.5 raised
face flange (smallest size)
• Approx. 17.7 kg (39.02 lb) for
6" Class 150 ASME B16.5 raised
face flange (largest size)
Display (local)
• Intrinsically Safe (China)
• Non-sparking/Energy Limited
(China)
• Intrinsically Safe (Europe)
Graphic local user interface including
quick start wizard and echo profile
display
• Increased Safety
(-International/Europe)
• Intrinsically Safe (International)
•
•
•
•
Explosion Proof (Russia)
Increased Safety (Russia)
Intrinsically Safe (Russia)
Marine
• Functional Safety
Antenna
• Material
• Dimensions (nominal sizes)
4/234
• Flame Proof/Increased Safety
(China)
• Non-sparking/Energy Limited
(Europe)
• Flame Proof (International/Europe)
Enclosure
• Material
• Cable inlet
Siemens FI 01 · 2015
Stainless Steel 316L (1.4435 or
1.4404) and TFM 1600 PTFE Lens
(lens is the only wetted part)
48 mm (2 inch), 80 mm (3 inch),
100 mm (4 inch), 150 mm (6 inch)
Raised Face
INMETRO Ex d ia mb IIC T4 Ga/Gb,
Ex ia ta IIIC T100 °C Da
INMETRO Ex e ia mb IIC T4 Ga/Gb,
Ex ia ta IIIC T100 °C Da
INMETRO Ex ia IIC T4 Ga, Ex ia ta
IIIC T100 °C Da
CSA/FM Class I, Div. 1,
Groups A, B, C, D; Class II, Div. 1,
Groups E, F, G; Class III T4
CSA/FM Class I, Div. 1,
Groups A, B, C, D; Class II, Div. 1,
Groups E, F, G; Class III T4
CSA/FM Class I, Div. 2,
Groups A, B, C, D T5
NEPSI Ex d ia mb IIC T4 Ga/Gb,
Ex e ia mb IIC T4 Ga/Gb, Ex iaD 20
T90 IP67 DIP A20 TA90 ºC
NEPSI Ex ia IIC T4 Ga, Ex iaD 20 T90
IP67 DIP A20 TA90 ºC
NEPSI Ex nA IIC T4 Gc
ATEX II 1G Ex ia IIC T4 Ga
ATEX II 1D Ex ia ta IIIC T100 °C Da
ATEX II 3G Ex nA IIC T4 Gc
IECEx/ATEX II 1/2 GD, 1D, 2D
Ex d mb ia IIC T4 Ga/Gb, Ex ia ta IIC
T100 °C Da
IECEx/ATEX II 1/2 GD, 1D, 2D,
Ex e mb ia IIC T4 Ga/Gb, Ex ia ta IIIC
T100 °C Da
IECEx/ATEX II 1 G Ex ia IIC T4 Ga,
IECEx/ATEX II 1D Ex ia ta IIIC
T100 °C Da
GOST-R Ex d
GOST-R Ex e
GOST-R Ex ia
• Lloyd’s Register of Shipping
• ABS Type Approval
• Bureau Veritas
SIL-2 suitable in accordance with
IEC 61508/61511
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Flanged Encapsulated Antenna
Programming
Selection and Ordering data
Intrinsically Safe Siemens handheld
programmer
• Approvals for handheldprogrammer
Infrared receiver
Handheld communicator
HART communicator 375/475
PC
• SIMATIC PDM
• Emerson AMS
• SITRANS DTM (for connection into
FDT, such as PACTware or
Fieldcare)
Display (local)
Graphic local user interface including
quick start wizard and echo profile
displays
IS model: ATEX II 1 GD Ex ia IIC T4
Ga Ex ia D 20 T135 °C
Ta = -20 ... +50 °C
CSA/FM Class I, II, III, Div. 1,
Groups A, B, C, D, E, F, G, T6
Ta = 50 °C IECEx SIR 09.0073
SITRANS LR250 flanged encapsulated antenna
2-wire, 25 GHz pulse radar level transmitter for
continuous monitoring of liquids and slurries in
storage and process vessels including high
temperature and pressure, to a range of 20 m (66 ft)
(antenna dependant). Ideal for corrosive, aggressive
and low dielectric media.
Article No.
7ML54327 7 7 7 0 - 77 7 7
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Process Connection Material
Stainless steel 1.4404/1.4435
0
Process Connection Type
Flanged Process Connection Types
(stainless steel 1.4404/1.4435)
2" Class 150 ASME B16.5 raised face1)
¢ BF
3" Class 150 ASME B16.5 raised face
¢ BG
4" Class 150 ASME B16.5 raised face
¢ BH
6" Class 150 ASME B16.5 raised face
BJ
1)
50A 10K JIS B 2220 raised face
FD
80A 10K JIS B 2220 raised face
FE
100A 10K JIS B 2220 raised face
FF
150A 10K JIS B 2220 raised face
FG
1)
DN 50 PN 10/16 EN 1092-1 type B1 raised face
¢ GA
DN 80 PN 10/16 EN 1092-1 type B1 raised face
¢ GB
DN 100 PN 10/16 EN 1092-1 type B1 raised face
¢ GC
DN 150 PN 10/16 EN 1092-1 type B1 raised face
GD
Communication/Output
PROFIBUS PA
¢
1
4 ... 20 mA, HART, start-up at < 3.6 mA
¢
2
FOUNDATION Fieldbus
¢
3
Enclosure/Cable inlet
Aluminum, Epoxy painted
2 x ½" NPT
¢
2 x M20x1.5
¢
Antenna lens material
¢
TFM 1600 PTFE Flush Lens
Approvals
General Purpose, CE, CSA, FM, FCC, R&TTE,
¢
RCM
Intrinsically Safe: CSA/FM Class I, Div. 1, Groups A, ¢
B, C, D, Class II, Div.1, Groups E, F, G, Class III T4
FCC, Industry Canada
Intrinsically Safe: IECEx/ATEX II 1 G Ex ia IIC T4 Ga, ¢
IECEx/ATEX II 1D Ex ia ta IIIC T100 °C Da, INMETRO
Ex ia IIC T4 Ga, Ex ia ta IIIC T100 oC Da, CE, R&TTE,
RCM
Non-incendive: CSA/FM Class I, Div. 2, Groups A, B, ¢
C, D T5, FCC, Industry Canada
Non Sparking: ATEX II 3G Ex nA IIC T4 Gc, CE,
¢
R&TTE, RCM
Increased Safety: IECEx/ATEX II 1/2 GD,1D,
¢
2D Ex e mb ia IIC T4 Ga/Gb, Ex ia ta IIIC T100 °C
Da, INMETRO Ex e ia mb IIC T4 Ga/Gb, Ex ia ta IIIC
T100 oC Da, CE, R&TTE, RCM2)
Flameproof: IECEx/ATEX II 1/2 GD 1D, 2D Ex d mb ia ¢
IIC T4 Ga/Gb, Ex ia ta IIIC T100 °C Da, INMETRO Ex
d ia mb IIC T4 Ga/Gb, Ex ia ta IIIC T100 oC Da, CE,
R&TTE, RCM2)
Explosion proof: CSA/FM Class I, II and III, Div.1,
¢
Groups A, B, C, D, E, F, G, FCC, Industry Canada2)
Non Sparking: NEPSI Ex nA IIC T4 Gc
¢
Intrinsically Safe: NEPSI Ex ia IIC T4 Ga,
¢
Ex iaD 20 T90 IP67 DIP A20 TA90 ºC
Flameproof: NEPSI Ex d ia mb IIC T4 Ga/Gb,
¢
Ex iaD 20 T90 IP67 DIP A20 TA90 ºC2)
Increased Safety: NEPSI Ex e ia mb IIC T4 Ga/Gb, ¢
Ex iaD 20 T90 IP67 DIP A20 TA90 ºC2)
Pressure rating
Rating per Pressure/Temperature curves in
¢
instruction manual
4
0
1
A
A
B
C
D
E
F
G
H
K
L
M
N
0
1)
Maximum range 10 m (32.8 ft), dk > 3 [20 m (66 ft)] and dk>1.6 when
mounted in stillpipe]
2)
Applicable with communication option 2 only
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Siemens FI 01 · 2015
4/235
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Flanged Encapsulated Antenna
Selection and Ordering data
Order code
Further designs
Article No.
Operating Instructions for
FOUNDATION Fieldbus device
Please add "-Z" to Article No. and specify Order
code(s).
Plug M12 with mating Connector1)2)3)
¢ A50
Plug 7/8" with mating Connector2)3)4)
¢ A55
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Measuring-point number/identification
(max. 27 characters); specify in plain text
4
Selection and Ordering data
Manufacturer's test certificate: M to DIN 55350,
Part 18 and to ISO 9000
¢ C11
Inspection Certificate Type 3.1 per EN 10204
¢ C12
Functional Safety (SIL 2). Device suitable for use in ¢ C20
accordance with IEC 61508 and IEC 615115)6)
Namur NE43 compliant, device preset to failsafe ¢ N07
< 3.6 mA5)
English
A5E32221411
German
Note: The Operating Instructions should be ordered as a separate line item on the order.
A5E32376112
Compact Operating Instructions for
FOUNDATION Fieldbus device
English, French, German, Spanish, Italian, Dutch,
Danish, Finnish, Greek, Portuguese (Portugal),
Swedish
A5E33472700
English, Bulgarian, Czech, Estonian, Hungarian,
Latvian, Lithuanian, Polish, Romanian, Slovakian,
Slovenian
A5E33472738
Operating Instructions for HART/mA device
Article No.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Compact Operating Instructions and Operating Instructions library.
English
A5E32220602
Accessories
German
Note: The Operating Instructions should be ordered as a separate line item on the order.
A5E32376088
Handheld programmer, Intrinsically safe, EEx ia
7ML1930-1BK
HART modem/USB
(for use with a PC and SIMATIC PDM)
7MF4997-1DB
7ML1930-1AP
Compact Operating Instructions for HART/mA
device
English, French, German, Spanish, Italian, Dutch,
Danish, Finnish, Greek, Portuguese (Portugal),
Swedish
A5E33469191
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F),
HART (2 are required)6)
7ML1930-1AQ
English, Bulgarian, Czech, Estonian, Hungarian,
Latvian, Lithuanian, Polish, Romanian, Slovakian,
Slovenian
A5E33469171
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F), PROFIBUS PA
and FOUNDATION Fieldbus (2 are required)2)
SITRANS RD100, loop powered display see Chapter 7
7ML5741-...
SITRANS RD200, universal input display with
Modbus conversion - see Chapter 7
7ML5740-...
SITRANS RD300, dual line display with totalizer
and linearization curve and Modbus conversion see Chapter 7
7ML5744-...
SITRANS RD500 web, universal remote monitoring
solution for instrumentation - see Chapter 7
7ML5750-...
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Compact Operating Instructions and Operating Instructions library.
Operating Instructions for PROFIBUS PA device
English
A5E32221386
German
Note: The Operating Instructions should be ordered as a separate line item on the order.
A5E32376094
For applicable back up point level switch see point level measurement section
Compact Operating Instructions for
PROFIBUS PA device
English, French, German, Spanish, Italian, Dutch,
Danish, Finnish, Greek, Portuguese (Portugal),
Swedish
A5E33469239
English, Bulgarian, Czech, Estonian, Hungarian,
Latvian, Lithuanian, Polish, Romanian, Slovakian,
Slovenian
A5E33472685
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Compact Operating Instructions and Operating Instructions library.
4/236
Siemens FI 01 · 2015
1)
Available with enclosure option 1 only
2)
Available with communication options 1 and 3 only
3)
Available with approval options A, B, C, and L only
4)
Available with enclosure option 0 only
5)
Applicable with communication option 2 only
6)
Available with approval options A, B, C, D, E, K, and L only
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Flanged Encapsulated Antenna
■ Characteristic curves
Pressure/ temperature curve
LR250 Flanged Encapsulated Antenna
ASME flanged process connections
(7ML5432)
Permitted operating pressures P
4
30 bar (435 psi)
2, 3, and 4" NPS
20 bar (290 psi)
6" NPS
ASME 150 lb
10 bar (145 psi)
Atmospheric
Pressure
-40 °F
14 °F
(-40 °C) (-10 °C)
100 °F
200 °F
300 °F
400 °F
(38 °C)
(93 °C)
(149 °C)
(204 °C)
T
-1 bar (-14.5 psi)
-50 °C
RT
0 °C
(32 °F)
(-58 °F)
-29 °C
(-20 °F)
50 °C
100 °C
150 °C
200 °C
(122 °F)
(212 °F)
(302 °F)
(392 °F)
170 °C
(338 °F)
Permitted operating temperatures
SITRANS LR250 flanged encapsulated antenna pressure/temperature curve
Pressure/ temperature curve
LR250 Flanged Encapsulated Antenna
EN 1092-1 flanged process connections
(7ML5432)
Permitted operating pressures P
30 bar (435 psi)
DN 150
DN 100
DN 50, DN 80
20 bar (290 psi)
PN 16
10 bar (145 psi)
Atmospheric
Pressure
-40 °F
14 °F
(-40 °C) (-10 °C)
100 °F
200 °F
300 °F
400 °F
(38 °C)
(93 °C)
(149 °C)
(204 °C)
T
-1 bar (-14.5 psi)
-50 °C
RT
(-58 °F)
-29 °C
(-20 °F)
0 °C
(32 °F)
50 °C
100 °C
150 °C
200 °C
(122 °F)
(212 °F)
(302 °F)
(392 °F)
170 °C
Permitted operating temperatures
(338 °F)
SITRANS LR250 flanged encapsulated antenna pressure/temperature curve
Siemens FI 01 · 2015
4/237
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Flanged Encapsulated Antenna
Pressure/ temperature curve
LR250 Flanged Encapsulated Antenna
JIS B 2220 flanged process connections
(7ML5432)
Permitted operating pressures
3
EDUSVL
$
$
$$
EDUSVL
.
4
EDUSVL
Atmospheric
Pressure
ഘ ഘ
ഒ ഒ
ഘ
ഒ
ഘ
ഒ
ഘ
ഒ
ഘ
ഒ
7
EDUSVL
ഒ
ഘ
57
ഒ
ഘ
ഒ
ഘ
ഒ
ഘ
ഒ
ഘ
ഒ
ഘ
Permitted operating temperatures
SITRANS LR250 flanged encapsulated antenna pressure/temperature curve
4/238
Siemens FI 01 · 2015
ഒ
ഘ
ഒ
ഘ
ഒ
ഘ
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Flanged Encapsulated Antenna
■ Dimensional drawings
Flanged Encapsulated Antenna 2"/DN 50/50A
½" NPT cable entry
(or alternatively,
M20 cable gland)
50
(2.0)
Threaded cover
4
167
(6.6)
153
(6.0)
90
3.5
Enclosure
"B"
Retaining
collar
"D"
"A"
"C"
Flange
Sensor
ref.
point
"E"
Flange
Size
2"
DN 50
50A
1)
Flange
Class
150 lb
Flange
O.D.
Antenna
Height to
Dimension
Beam Measurement
see
LR250_E_Installation.cdr
for
dim. values.
aperture
Sensor
Range
A
angle
reference point
dimension E1)
50
(1.97)
11
(0.43)
Dimension
D
152 (5.98)
PN 10/16 165 (6.50)
10K
size
Dimension Dimension
B
C
155 (6.10)
12.8°
10 m
(32.8 ft)
263
(10.35)
178
(7)
223
(8.78)
274
(10.79)
Height from tip of lens to sensor reference point as shown.
SITRANS LR250 flanged encapsulated antenna, dimensions in mm (inch)
Siemens FI 01 · 2015
4/239
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Flanged Encapsulated Antenna
Flanged Encapsulated Antenna 3"/DN 50/80A or greater
½" NPT cable entry
(or alternatively,
M20 cable gland)
50
(2.0)
Threaded cover
4
167
(6.6)
153
(6.0)
90
3.5
Enclosure
"B"
Retaining
collar
"D"
"A"
"C"
Flange
Sensor
ref.
point
"E"
Flange
Size
3"
DN 80
80A
4"
Flange
Class
Flange
O.D.
150 lb
190 (7.48)
150 lb
150A
10K
15
(0.59)
9.6°
20 m
(65.6 ft)
328
(12.91)
178
(7)
288
(11.34)
343
(13.54)
75
(2.95)
13
(0.51)
9.6°
20 m
(65.6 ft)
328
(12.91)
178
(7)
288
(11.34)
343
(13.50)
75
(2.95)
15
(0.59)
9.6°
20 m
(65.6 ft)
333
(13.11)
178
(7)
293
(11.54)
348
(13.70)
280 (11.02)
Height from tip of lens to sensor reference point as shown.
SITRANS LR250 flanged encapsulated antenna, dimensions in mm (inch)
4/240
Dimension Dimension
B
C
Dimension
D
280 (11.02)
DN 150 PN 10/16 285 (11.25)
1)
75
(2.95)
Beam Measurement Dimension
Range
angle
A
230 (9.06)
DN 100 PN 10/16 220 (8.66)
100A
10K
210 (8.27)
6"
Height to
Sensor
reference point
dimension E1)
see LR250_E_Installation.cdr for dim. values.
PN 10/16 200 (7.87)
10K
185 (7.28)
150 lb
Antenna
aperture
size
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Flanged Encapsulated Antenna
■ Schematics
Connect the wires to the
terminals as shown: the
polarity is identified on the
terminal block.
Gland
Hand Programmer
Shield for HART,
PROFIBUS PA , and
FOUNDATION Fieldbus
Intrinsically Safe
versions only.
4
Part number:
7ML1930-1BK
Notes:
1. DC terminal shall be supplied from a source providing electrical isolation between the input and output, to meet the applicable
safety requirements of IEC 61010-1.
2. All field wiring must have insulation suitable for rated input voltages.
3. Use shielded twisted pair cable (14 ... 22 AWG) for HART version.
4. Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes.
SITRANS LR250 connections
Siemens FI 01 · 2015
4/241
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Flanged Encapsulated Specials
■ Selection and ordering data
SITRANS LR250 flanged encapsulated Specials
SITRANS LR250 flanged encapsulated Specials
Article No.
4
SITRANS LR250 flanged encapsulated antenna
version enclosures
(PROFIBUS PA models)
LR250 flanged encapsulated antenna version
(7ML5432) enclosure with board stack, M20 cable
inlet, approval option A, with PROFIBUS PA
communication, no process connection
LR250 flanged encapsulated antenna version
(7ML5432) enclosure with board stack, NPT cable
inlet, approval option A, with PROFIBUS PA
communication, no process connection
LR250 flanged encapsulated antenna version
(7ML5432) enclosure with board stack, NPT cable
inlet, approval option B, with PROFIBUS PA
communication, no process connection
LR250 flanged encapsulated antenna version
(7ML5432) enclosure with board stack, M20 cable
inlet, approval option C, with PROFIBUS PA
communication, no process connection
LR250 flanged encapsulated antenna version
(7ML5432) enclosure with board stack, NPT cable
inlet, approval option D, with PROFIBUS PA
communication, no process connection
LR250 flanged encapsulated antenna version
(7ML5432) enclosure with board stack, M20 cable
inlet, approval option E, with PROFIBUS PA
communication, no process connection
SITRANS LR250 flanged encapsulated
antenna version enclosures
(FOUNDATION Fieldbus models)
LR250 flanged encapsulated antenna version
(7ML5432) enclosure with board stack,
M20 cable inlet, approval option A,
with FOUNDATION Fieldbus communication,
no process connection
LR250 flanged encapsulated antenna version
(7ML5432) enclosure with board stack,
NPT cable inlet, approval option A,
with FOUNDATION Fieldbus communication,
no process connection
LR250 flanged encapsulated antenna version
(7ML5432) enclosure with board stack,
NPT cable inlet, approval option B,
with FOUNDATION Fieldbus communication,
no process connection
LR250 flanged encapsulated antenna version
(7ML5432) enclosure with board stack,
M20 cable inlet, approval option C,
with FOUNDATION Fieldbus communication,
no process connection
LR250 flanged encapsulated antenna version
(7ML5432) enclosure with board stack,
NPT cable inlet, approval option D,
with FOUNDATION Fieldbus communication,
no process connection
LR250 flanged encapsulated antenna version
(7ML5432) enclosure with board stack,
M20 cable inlet, approval option E,
with FOUNDATION Fieldbus communication,
no process connection
SITRANS LR250 flanged encapsulated
antenna version enclosures
(< 3.6 mA start-up HART models)
LR250 flanged encapsulated antenna version
(7ML5432) enclosure with board stack,
M20 cable inlet, approval option A,
with HART communication start-up
at < 3.6 mA, no process connection
LR250 flanged encapsulated antenna version
(7ML5432) enclosure with board stack,
NPT cable inlet, approval option A,
with HART communication start-up
at < 3.6 mA, no process connection
4/242
Siemens FI 01 · 2015
A5E32462853
A5E32462854
A5E32462855
A5E32462856
A5E32462857
A5E32462858
A5E32462859
A5E32462860
A5E32462861
A5E32462862
A5E32462863
A5E32462864
A5E32462865
A5E32462866
Article No.
LR250 flanged encapsulated antenna version
(7ML5432) enclosure with board stack,
NPT cable inlet, approval option B,
with HART communication start-up
at < 3.6 mA, no process connection
LR250 flanged encapsulated antenna version
(7ML5432) enclosure with board stack,
M20 cable inlet, approval option C,
with HART communication start-up
at < 3.6 mA, no process connection
LR250 flanged encapsulated antenna version
(7ML5432) enclosure with board stack,
NPT cable inlet, approval option D,
with HART communication start-up
at < 3.6 mA, no process connection
LR250 flanged encapsulated antenna version
(7ML5432) enclosure with board stack,
M20 cable inlet, approval option E,
with HART communication start-up
at < 3.6 mA, no process connection
LR250 flanged encapsulated antenna version
(7ML5432) enclosure with board stack,
M20 cable inlet, approval option F,
with HART communication start-up
at < 3.6 mA, no process connection
LR250 flanged encapsulated antenna version
(7ML5432) enclosure with board stack,
M20 cable inlet, approval option G,
with HART communication start-up
at < 3.6 mA, no process connection
LR250 flanged encapsulated antenna version
(7ML5432) enclosure with board stack,
NPT cable inlet, approval option H,
with HART communication start-up
at < 3.6 mA, no process connection
SITRANS LR250 flanged encapsulated
antenna lens kits
Replacement TFM 1600 Lens and Spring Washer
Kit for 2" Class 150 ASME B16.5 raised face
Replacement TFM 1600 Lens and Spring Washer
Kit for 3" Class 150 ASME B16.5 raised face
Replacement TFM 1600 Lens and Spring Washer
Kit for 4" Class 150 ASME B16.5 raised face
Replacement TFM 1600 Lens and Spring Washer
Kit for 6" Class 150 ASME B16.5 raised face
Replacement TFM 1600 Lens and Spring Washer
Kit for 50A 10K JIS B 2220 raised face
Replacement TFM 1600 Lens and Spring Washer
Kit for 80A 10K JIS B 2220 raised face
Replacement TFM 1600 Lens and Spring Washer
Kit for 100A 10K JIS B 2220 raised face
Replacement TFM 1600 Lens and Spring Washer
Kit for 150A 10K JIS B 2220 raised face
Replacement TFM 1600 Lens and Spring Washer
Kit for DN 50 PN 10/16 EN 1092-1 type B1 raised
face
Replacement TFM 1600 Lens and Spring Washer
Kit for DN 80 PN 10/16 EN 1092-1 type B1 raised
face
Replacement TFM 1600 Lens and Spring Washer
Kit for DN 100 PN 10/16 EN 1092-1 type B1 raised
face
Replacement TFM 1600 Lens and Spring Washer
Kit for DN 150 PN 10/16 EN 1092-1 type B1 raised
face
A5E32462867
A5E32462868
A5E32462869
A5E32462830
A5E32462831
A5E32462832
A5E32462833
A5E32462817
A5E32462819
A5E32462820
A5E32462821
A5E32462822
A5E32462823
A5E32462824
A5E32462825
A5E32462826
A5E32462827
A5E32462828
A5E32462829
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna
■ Overview
■ Application
SITRANS LR250 includes a graphical local user interface (LUI)
that improves set-up and operation by including an intuitive
Quick Start Wizard, and echo profile displays for diagnostic support. Start-up is easy using the Quick Start wizard with few
parameters required for basic operation.
The 25 GHz frequency creates a narrow, focused beam allowing
for smaller antenna options and decreasing sensitivity to
obstructions.
SITRANS LR250’s unique design allows safe and simple programming using the Intrinsically Safe handheld programmer
without having to open the instrument’s lid.
The SITRANS LR250 hygienic encapsulated antenna is a 2 wire
25 GHz pulse radar level transmitter with sanitary and hygienic
approvals for continuous monitoring of liquids, slurries and
pastes within the Food, Beverage, chemical, and pharmaceutical industries to a range of 20 m (66 ft) - antenna dependent
(Picture shown with accessories sold separately).
SITRANS LR250 measures superbly in small vessels and in
tanks/vessels up to 20 m (66 ft) on materials with dk > 1.6.
• Key Applications: applications within the Food, Beverage,
Chemical and Pharmaceutical industries where sanitary,
aseptic or hygienic approvals are required or easy install/
clean flush antennas are preferable, such as ice cream,
fruit juice, milk, beer, and pharmaceutical or chemical
additives and ingredients.
■ Configuration
Installation
■ Benefits
• Fully encapsulated horn antenna design with FDA approved
and USP Class VI compliant, TFM 1600 PTFE lens.
• < 0.8  Ra surface finish for maximum cleanability and
hygiene requirements commonly required in sanitary environments
• Chemically resistant TFM 1600 PTFE lens is also suitable for
aggressive or corrosive materials
• Approved device in accordance with 3-A, EHEDG EL Class I
and/or EHEDG EL Aseptic Class I
• Cost effective replacement for transmitters made of exotic
materials
• Graphical local user interface (LUI) makes operation simple
with plug-and-play set-up using the intuitive Quick Start
Wizard
• Industry standard process connections including ISO 2852,
DIN 11851, DIN 11864-1, DIN 11864-2, DIN 11864-3 and
Tuchenhagen Varivent Type F and N
• LUI displays echo profiles for diagnostic support
• 25 GHz high frequency and 2 inch (50 mm) process
connection/antenna allow for easy mounting
• Insensitive to mounting location and obstructions, and less
sensitive to nozzle interference
• Communication using HART, PROFIBUS PA,
or FOUNDATION Fieldbus
• Process Intelligence signal processing for improved
measurement reliability and Auto False-Echo Suppression of
fixed obstructions
• Programming using infrared Intrinsically Safe handheld
programmer or over a network using SIMATIC PDM,
Emerson AMS, or Field Device Tools, such as PACTware or
Fieldcare via SITRANS DTM.
• Functional Safety (SIL 2). Device suitable for use in accordance with IEC 61508 and IEC 61511
Note:
• Beam angle is the width of the
cone where the energy density
is half of the peak energy
density.
• The peak energy density is
directly in front of and in line
with the antenna.
• There is a signal transmitted
outside of the beam angle;
therefore false targets may be
detected.
Mounting unit on vessel
3"/DN 80/80A
or larger
9.6°
2"/DN 50
/50A
12.8°
Mounting on a nozzle
l
d
Nozzles should be
maximum l/d ratio 1:1
(Eg. 50 mm length,
50 mm diameter)
SITRANS LR250 Hygienic Encapsulated Antenna Installation, dimensions in mm (inch)
Siemens FI 01 · 2015
4/243
4
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna
■ Technical specifications
Mode of Operation
Process connections
Measuring principle
Radar level measurement
Frequency
K-band (25.0 GHz)
Minimum measuring range
50 mm (2 inch) from end of antenna
Maximum measuring range
20 m (66 ft)
Hygienic/Sanitary connections
Output
4
• 2", 3" & 4" Sanitary Clamp according
to ISO 2852
• DN 50, DN 80 & DN 100 Aseptic/
Hygienic threaded to DIN 11864-1
[Form A]
• DN 50, DN 80 & DN 100 Aseptic/
Hygienic flanged to DIN 11864-2
[Form A]
• DN 50, DN 80 & DN 100 Aseptic/
Hygienic Clamp according to
DIN 11864-3 [Form A]
• DN 50, DN 80 & DN 100 Hygienic
Union according to DIN 11851
• Type F (50 mm) & Type N (68 mm)
Tuchenhagen Varivent
HART
• Analog output
• Accuracy
• Fail-safe
Version 5.1
4 ... 20 mA
± 0.02 mA
• Programmable as high low or hold
(loss of echo)
• NE 43 programmable
PROFIBUS PA
• Function blocks
Profile 3.01
2 Analog Input (AI)
Power supply
4 ... 20 mA/HART
FOUNDATION Fieldbus
• Functionality
• Version
• Function blocks
H1
Basic or LAS
ITK 5.2.0
2 Analog Input (AI)
Nominal 24 V DC (max. 30 V DC) with
max. 550 
PROFIBUS PA
• 15 mA
• Per IEC 61158-2
FOUNDATION Fieldbus
• 20.0 mA
• Per IEC 61158-2
Performance (according to reference conditions IEC60770-1)
Maximum measured error
Influence of ambient temperature
Certificates and approvals
• > 500 mm from sensor reference
point: 3 mm (0.118 inch)
• < 500 mm from sensor reference
point: 25 mm (1 inch)
< 0.003 %/K
Rated operating conditions
Installation conditions
Location
General
CSAUS/C, CE, FM, NE 21, RCM
Radio
FCC, Industry Canada and Europe
ETSI EN 302-372, RCM
Hazardous
• Explosion Proof (Brazil)
• Explosion Proof (Russia)
• Increased Safety (Russia)
• Intrinsically Safe (Russia)
INMETRO Ex d ia mb IIC T4 Ga/Gb,
Ex ia ta IIIC T100 °C Da
INMETRO Ex e ia mb IIC T4 Ga/Gb,
Ex ia ta IIIC T100 °C Da
INMETRO Ex ia IIC T4 Ga, Ex ia ta
IIIC T100 °C Da
CSA/FM Class I, Div. 1,
Groups A, B, C, D; Class II, Div. 1,
Groups E, F, G; Class III T4
CSA/FM Class I, Div. 1,
Groups A, B, C, D; Class II, Div. 1,
Groups E, F, G; Class III T4
CSA/FM Class I, Div. 2,
Groups A, B, C, D T5
NEPSI Ex d ia mb IIC T4 Ga/Gb,
Ex e ia mb IIC T4 Ga/Gb, Ex iaD 20
T90 IP67 DIP A20 TA90 ºC
NEPSI Ex ia IIC T4 Ga, Ex iaD 20 T90
IP67 DIP A20 TA90 ºC
NEPSI Ex nA IIC T4 Gc
ATEX II 1G Ex ia IIC T4 Ga ATEX II 1D
Ex ia ta IIIC T100 °C Da
ATEX II 3G Ex nA IIC T4 Gc
IECEx/ATEX II 1/2 GD, 1D, 2D
Ex d mb ia IIC T4 Ga/Gb, Ex ia ta IIC
T100 °C Da
IECEx/ATEX II 1/2 GD, 1D, 2D,
Ex e mb ia IIC T4 Ga/Gb, Ex ia ta IIIC
T100 °C Da
IECEx/ATEX II 1 G Ex ia IIC T4 Ga,
IECEX/ATEX II 1D Ex ia ta IIIC
T100 °C Da
GOST-R Ex d
GOST-R Ex e
GOST-R Ex ia
Hygienic/Sanitary
EHEDG EL Class I
• Increased Safety (Brazil)
Indoor/outdoor
• Intrinsically Safe (Brazil)
Ambient conditions (enclosure)
Ambient temperature
-40 ... +80 °C (-40 ... +176 °F)
Installation category
I
Pollution degree
4
• Intrinsically Safe (Canada/USA)
Dielectric constant r
 1.6 (antenna dependent)
• Non-incendive (Canada/USA)
Process temperature
-40 ... +170 °C (-40 ... +338 °F) at
process connection
Process pressure
See Pressure/Temperature curves for
more information
• Explosion Proof (Canada/USA)
Medium conditions
Design
Enclosure
• Material
• Cable inlet
Aluminum, polyester powder coated
2 x M20x1.5 or 2 x ½" NPT
Degree of protection
Type 4X/NEMA 4X, Type 6/NEMA 6,
IP67, IP68
Weight (dependent on process connection)
• Approx. 4.7 kg (10.4 lb) for
2" ISO 2852 (smallest size)
• Approx. 7.9 kg (17.4 lb) for
DN 100 DIN 11864-2 (largest size)
Display (local)
Graphic local user interface including
quick start wizard and echo profile
display
Antenna
• Material
• Lens surface finish (Ra)
4/244
Siemens FI 01 · 2015
Stainless steel 316L (1.4435 or
1.4404) and TFM 1600 PTFE Lens
(lens is the only wetted part)
0.8 µm
• Flame Proof/Increased Safety
(China)
• Intrinsically Safe (China)
• Non-sparking (China)
• Intrinsically Safe (Europe)
• Non-sparking (Europe)
• Flame Proof (International/Europe)
• Increased Safety
(International/Europe)
• Intrinsically Safe (International)
EHEDG EL Aseptic Class I
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna
Programming
Intrinsically Safe Siemens handheld Infrared receiver
programmer
• Approvals for handheld program- IS model:
ATEX II 1 GD Ex ia IIC T4 Ga
mer
Ex ia D 20 T135 °C
Ta = -20 ... +50 °C
CSA/FM Class I, II, III, Div. 1.,
Groups A, B, C, D, E, F, G, T6
Ta = 50 °C
IECEx SIR 09.0073
Handheld communicator
HART communicator 375/475
PC
• SIMATIC PDM
• Emerson AMS
• SITRANS DTM (for connection into
FDT, such as PACTware or Fieldcare)
Display (local)
Graphic local user interface including
quick start wizard and echo profile
displays
4
Siemens FI 01 · 2015
4/245
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna
4
Selection and Ordering data
Article No.
Selection and Ordering data
Article No.
SITRANS LR250 hygienic encapsulated antenna
2-wire, 25 Ghz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage
and process vessels including high temperature
and pressure, up to a range of 20 m (66 ft)
(Antenna dependant). Ideal for Hygienic applications including small vessels and low dielectric
media.
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Hygienic/Sanitary Approvals
7ML543377 7 7 0 - 7A 77
SITRANS LR250 hygienic encapsulated antenna
2-wire, 25 Ghz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage
and process vessels including high temperature
and pressure, up to a range of 20 m (66 ft)
(Antenna dependant). Ideal for Hygienic applications including small vessels and low dielectric
media.
Communication
7ML543377 7 7 0 - 7A 77
¢
EHEDG EL Class I1)
¢
EHEDG EL Aseptic Class I1)
3-A (Tuchenhagen connections only - FC ... FF) 2)3)¢
EHEDG EL Class I & 3-A (excludes Tuchenhagen ¢
connections)4)
Process Connection Types (all types have
TFM1600 PTFE lens)
1
2
3
4
316L st/st [1.4435 or 1.4404]
2" Sanitary Clamp according to ISO 28525)
3" Sanitary Clamp according to ISO 2852
4" Sanitary Clamp according to ISO 2852
¢
¢
¢
AA
AB
AC
DN 50 Aseptic/Hygienic nozzle/ slotted nut
(instrument side) to DIN 11864-1 [Form A]5)
DN 80 Aseptic/Hygienic nozzle/ slotted nut
(instrument side) to DIN 11864-1 [Form A]
DN 100 Aseptic/Hygienic nozzle/ slotted nut
(instrument side) to DIN 11864-1 [Form A]
316L st/st [1.4435 or 1.4404]
BA
DN 50 Aseptic/Hygienic flanged to DIN 11864-2
[Form A]5)
DN 80 Aseptic/Hygienic flanged to DIN 11864-2
[Form A]
DN 100 Aseptic/Hygienic flanged to DIN 11864-2
[Form A]
316L st/st [1.4435 or 1.4404]
CA
DN 50 Aseptic/Hygienic Clamp according to
DIN 11864-3 [Form A]5)
DN 80 Aseptic/Hygienic Clamp according to
DIN 11864-3 [Form A]
DN 100 Aseptic/Hygienic Clamp according to
DIN 11864-3 [Form A]
316L st/st (1.4435 or 1.4404) & 304L st/st (1.4301)
DA
DN 50 Hygienic nozzle/ slotted nut
(instrument side) to DIN 118515)
DN 80 Hygienic nozzle/ slotted nut
(instrument side) to DIN 11851
DN 100 Hygienic nozzle/ slotted nut
(instrument side) to DIN 11851
316L st/st [1.4435 or 1.4404]
EA
Type F (50 mm) Tuchenhagen Varivent
(EHEDG only)5)
FA
Type N (68 mm) Tuchenhagen Varivent
(EHEDG only)5)
Type F (50 mm) Tuchenhagen Varivent
[3-A only & EPDM process seal -40 °C ... 120 °C
(-40 °F ... 248 °F )]5)
FB
Type N (68 mm) Tuchenhagen Varivent
[3-A only & EPDM process seal -40 °C ... 120 °C
(-40 °F ... 248 °F)]5)
FD
Type F (50 mm) Tuchenhagen Varivent
[3-A only & FKM process seal -20 °C ... 170 °C
(-4 °F ... 338 °F)]5)
FE
Type N (68 mm) Tuchenhagen Varivent
[3-A only & FKM process seal -20 °C ... 170 °C
(-4 °F ... 338 °F)]5)
EXCLUDE Process Connection - Electronics Head
assembly spare only (select all other options as
normal)
FF
Siemens FI 01 · 2015
¢
¢
1
2
FOUNDATION Fieldbus
Enclosure (with Cable Inlets)
¢
3
Aluminum, Epoxy paint, 2 X ½" NPT
Aluminum, Epoxy paint, 2 X M20 x 1.5
316L st/st (1.4435 or 1.4404) & 304L st/st (1.4301)
4/246
PROFIBUS PA
4 ... 20 mA HART, start-up at < 3.6 mA
BB
BC
CB
CC
DB
DC
EB
EC
FC
YY
¢
¢
0
1
Approvals
General Purpose, CE, CSA, FM, FCC, R&TTE, RCM ¢
A
¢
B
¢
C
¢
D
¢
E
¢
F
Flameproof: IECEx/ATEX II 1/2 GD 1D, 2D Ex d mb ¢
ia IIC T4 Ga/Gb, Ex ia ta IIIC T100 °C Da,
INMETRO Ex d ia mb IIC T4 Ga/Gb, Ex ia ta IIIC
T100 °C Da, CE, R&TTE, RCM6)
Explosion proof: CSA/FM Class I, II and III, Div. 1, ¢
Groups A, B, C, D, E, F, G, FCC, Industry Canada6)
G
¢
¢
K
L
¢
M
¢
N
Intrinsically Safe: CSA/FM Class I, Div. 1, Groups
A, B, C, D, Class II, Div. 1, Groups E, F, G, Class III
T4 FCC, Industry Canada
Intrinsically Safe: IECEx/ATEX II 1 GD Ex ia IIC T4
Ga, Ex ia ta IIIC T100 °C Da, INMETRO Ex ia IIC T4
Ga, Ex ia ta IIIC T100 °C Da, CE, R&TTE, RCM
Non-incendive: CSA/FM Class I, Div. 2,
Groups A, B, C, D T5, FCC, Industry Canada
Non Sparking: ATEX II 3G Ex nA IIC T4 Gc, CE,
R&TTE, RCM
Increased Safety: IECEx/ATEX II 1/2 GD, 1D,
2D Ex e mb ia IIC T4 Ga/Gb, Ex ia ta IIIC T100 °C
Da, INMETRO Ex e ia mb IIC T4 Ga/Gb,
Ex ia ta IIIC T100 °C Da, CE, R&TTE, RCM6)
Non Sparking: NEPSI Ex nA IIC T4 Gc
Intrinsically Safe: NEPSI Ex ia IIC T4 Ga, Ex iaD 20
T90 IP67 DIP A20 TA 90 ºC
Flameproof: NEPSI Ex d ia mb IIC T4 Ga/Gb,
Ex iaD 20 T90 IP67 DIP A20 TA 90 ºC6)
Increased Safety: NEPSI Ex e ia mb IIC T4 Ga/Gb,
Ex iaD 20 T90 IP67 DIP A20 TA 90 ºC6)
Pressure Rating
Rating per pressure/temperature curves in instruc- ¢
tion manual
H
0
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna
Selection and Ordering data
Order code
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
Electrical Connection cable entry:
Plug M12 (IP 67 rating) with mating connector2)7)8) ¢ A50
Plug 7/8" (IP 67 rating) with mating Connector2)8)9) ¢ A55
Test Certificates
Manufacturer's Test Certificate M to DIN 55350,
Part 18 and to ISO 9000
¢ C11
Inspection Certificate 3.1 of EN 10204
¢ C12
Functional Safety
Functional Safety (SIL 2). Device suitable for use in ¢ C20
accordance with IEC 61508 and IEC 615116)10)
Namur
Namur NE43 compliant, device preset to failsafe
< 3.6 mA6)
Tagging
Stainless steel tag [69 mm x 50 mm
(2.71 x 1.97 inch)]
Measuring-point number / identification
(max. 27 characters) specify in plain text
Article No.
Selection and Ordering data
Operating Instructions for
FOUNDATION Fieldbus device
¢ N07
English
A5E32221411
German
Note: The Operating Instructions should be ordered as a separate line item on the order.
A5E32376112
Compact Operating Instructions for
FOUNDATION Fieldbus device
English, French, German, Spanish, Italian, Dutch,
Danish, Finnish, Greek, Portuguese (Portugal),
Swedish
A5E33472700
English, Bulgarian, Czech, Estonian, Hungarian,
Latvian, Lithuanian, Polish, Romanian, Slovakian,
Slovenian
A5E33472738
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Compact Operating Instructions and Operating Instructions library.
4
Accessories
¢ Y15
Operating Instructions for HART/mA device
Article No.
English
A5E32220602
German
Note: The Operating Instructions should be ordered as a separate line item on the order.
A5E32376088
Compact Operating Instructions for HART/mA
device
Handheld programmer, Intrinsically safe, EEx ia
(LUI enabled)
7ML1930-1BK
HART modem/USB
(for use with a PC and SIMATIC PDM)
7MF4997-1DB
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F),
HART (two are required)6)
7ML1930-1AP
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F), PROFIBUS PA
and FOUNDATION Fieldbus (two are required)8)
7ML1930-1AQ
SITRANS RD100, loop powered display see Chapter 7
7ML5741-...
English, French, German, Spanish, Italian, Dutch,
Danish, Finnish, Greek, Portuguese (Portugal),
Swedish
A5E33469191
SITRANS RD200, universal input display with
Modbus conversion - see Chapter 7
7ML5740-...
A5E33469171
SITRANS RD300, dual line display with totalizer
and linearization curve and Modbus conversion see Chapter 7
7ML5744-...
English, Bulgarian, Czech, Estonian, Hungarian,
Latvian, Lithuanian, Polish, Romanian, Slovakian,
Slovenian
SITRANS RD500 web, universal remote monitoring
solution for instrumentation - see Chapter 7
7ML5750-...
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Compact Operating Instructions and Operating Instructions library.
For applicable back up point level switch see point level measurement section
Operating Instructions for PROFIBUS PA device
English
A5E32221386
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
German
Note: The Operating Instructions should be
ordered as a separate line item on the order.
A5E32376094
1)
Available with process connection options AA ... FB & YY only
2)
Available with Approval options A, B, C, L only
3)
Available with Process connection FC ... FF only
4)
Available with process connection options AA ... EC & YY only
5)
Max. range 10 m (32.8 ft), dk > 3 [20 m (66 ft) and dk > 1.6 if installed in a
stillpipe]
6)
Applicable with Communication option 2 only
7)
Available with Enclosure option 1 only
8)
Available with Communication options 1 & 3 only.
9)
Available with Enclosure option 0 only
Compact Operating Instructions for
PROFIBUS PA device
English, French, German, Spanish, Italian, Dutch,
Danish, Finnish, Greek, Portuguese (Portugal),
Swedish
A5E33469239
English, Bulgarian, Czech, Estonian, Hungarian,
Latvian, Lithuanian, Polish, Romanian, Slovakian,
Slovenian
A5E33472685
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Compact Operating Instructions and Operating Instructions library.
10) Available
with Approval options A, B, C, D, E, K, L only
Siemens FI 01 · 2015
4/247
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna
■ Characteristic curves
DIN 11851 Sanitary/Hygienic nozzle/slotted nut: DN 50, DN 80, and DN 100
DIN 11864-1 Aseptic/Hygienic nozzle/slotted nut: DN 50, DN 80, and DN 100
P
30 bar (435 psi)
20 bar (290 psi)
4
10 bar (145 psi)
-40°F 14°F
(-40°C) (-10°C)
1
100°F
(38°C)
200°F
(93°C)
300°F
(149°C)
400°F
(204°C)
T
-1 bar (-14.5 psi)
RT
-50°C
(-58°F)
0°C
(32°F)
100°C
(212°F)
50°C
(122°F)
150°C
(302°F)
-29°C
(-20°F)
1 Atmospheric
P Allowable operating pressures
T Allowable operating temperatures
200°C
(392°F)
170°C
(338°F)
SITRANS LR250 Hygienic Encapsulated Antenna, pressure/temperature curves
DIN 11864-2 Aseptic/Hygienic flanged: DN 50, DN 80, and DN 100
P
30 bar (435 psi)
20 bar (290 psi)
10 bar (145 psi)
-40°F 14°F
(-40°C) (-10°C)
1
100°F
(38°C)
200°F
(93°C)
300°F
(149°C)
400°F
(204°C)
T
-1 bar (-14.5 psi)
-50°C
(-58°F)
1
Atmospheric
P Allowable operating pressures
T Allowable operating temperatures
RT
0°C
(32°F)
50°C
(122°F)
-29°C
(-20°F)
Siemens FI 01 · 2015
150°C
200°C
(302°F)
(392°F)
170°C
(338°F)
Note: For pressure applications, all attachment hardware must be suitably rated.
SITRANS LR250 Hygienic Encapsulated Antenna, pressure/temperature curves
4/248
100°C
(212°F)
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna
DIN 11864-3 Aseptic/Hygienic clamp: DN 50, DN 80, and DN 100
IS0 2852 Sanitary/Hygienic clamp: 2", 3", and 4"
Tuchenhagen Varivent face seal clamp: Type N (68 mm) and Type F (50 mm)
P
30 bar (435 psi)
20 bar (290 psi)
4
10 bar (145 psi)
1
-40°F 14°F
(-40°C) (-10°C)
100°F
(38°C)
200°F
(93°C)
400°F
(204°C)
300°F
(149°C)
T
-1 bar (-14.5 psi)
-50°C
(-58°F)
1 Atmospheric
RT
0°C
(32°F)
50°C
(122°F)
-29°C
(-20°F)
100°C
(212°F)
150°C
(302°F)
200°C
(392°F)
170°C
(338°F)
P Allowable operating pressures
T Allowable operating temperatures
Note: For pressure applications, all clamps must be rated accordingly.
SITRANS LR250 Hygienic Encapsulated Antenna, pressure/temperature curves
Siemens FI 01 · 2015
4/249
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna
■ Dimensional drawings
Hygienic encapsulated antenna (2" ISO 2852 sanitary clamp)
50.0
(2.00)
1/2" NPT cable entry
(or alternatively, M20 cable gland)
Threaded cover
4
167.0
(6.57)
153.0
(6.02)
90.0
(3.54)
Enclosure
178.0
(7.01)
Retaining
collar
274.2
(10.80)
225.7
(8.89)
Process
connection
Ø44.0
(1.73)
Ø64.0
(2.52)
SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch)
4/250
Siemens FI 01 · 2015
Sensor
reference
point
11.0
(0.43)
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna
Hygienic encapsulated antenna (3" ISO 2852 sanitary clamp)
50.0
(2.00)
1/2" NPT cable entry (or alternatively, M20
cable gland)
Threaded cover
4
167.0
(6.57)
90.0
(3.54)
153.0
(6.02)
Enclosure
178.0
(7.01)
Retaining
collar
343.2
(13.51)
291.2
(11.46)
Process
connection
Ø74.7
(2.94)
Ø91.0
(3.58)
Sensor
reference
point
14.5
(0.57)
SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch)
Siemens FI 01 · 2015
4/251
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna
Hygienic encapsulated antenna (4" ISO 2852 sanitary clamp)
50.0
(2.00)
1/2" NPT cable entry (or alternatively, M20
cable gland)
Threaded cover
4
167.0
(6.57)
153.0
(6.02)
90.0
(3.54)
Enclosure
178.0
(7.01)
Retaining
collar
343.2
(13.51)
291.2
(11.46)
Process
connection
Sensor
reference
point
Ø74.7
(2.94)
Ø119.0
(4.69)
SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch)
4/252
Siemens FI 01 · 2015
14.5
(0.57)
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna
Hygienic encapsulated antenna (DN 50 nozzle/slotted nut to DIN 11851)
50.0
(2.00)
1/2" NPT cable entry (or alternatively, M20
cable gland)
Threaded cover
4
167.0
(6.57)
153.0
(6.02)
90.0
(3.54)
Enclosure
178.0
(7.01)
Retaining
collar
Threaded nut
225.7
(8.89)
274.2
(10.80)
Sensor
reference
point
Ø44.0
(1.73)
11.0
(0.43)
Ø57.6
(2.27)
Ø63.7
(2.51)
Note: Cut out of process connection and placement of threaded nut are shown for illustration
purposes only.
SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch)
Siemens FI 01 · 2015
4/253
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna
Hygienic encapsulated antenna (DN 80 nozzle/slotted nut to DIN 11851)
50.0
(2.00)
1/2" NPT cable entry (or alternatively, M20
cable gland)
Threaded cover
4
167.0
(6.57)
153.0
(6.02)
90.0
(3.54)
Enclosure
178.0
(7.01)
Retaining
collar
Threaded nut
343.2
(13.51)
291.2
(11.46)
Sensor
reference
point
Ø74.7
(2.94)
Ø88.6
(3.49)
Ø94.7
(3.73)
14.5
(0.57)
Note: Cut out of process connection and placement of threaded nut are shown for illustration
purposes only.
SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch)
4/254
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna
Hygienic encapsulated antenna (DN 100 nozzle/slotted nut to DIN 11851)
50.0
(2.00)
1/2" NPT cable entry (or alternatively, M20
cable gland)
Threaded cover
4
167.0
(6.57)
90.0
(3.54)
153.0
(6.02)
Enclosure
178.0
(7.01)
Retaining
collar
343.2
(13.51)
Threaded nut
291.2
(11.46)
Sensor
reference
point
Ø74.7
(2.94)
14.5
(0.57)
Ø107.6
(4.24)
Ø113.7
(4.48)
Note: Cut out of process connection and placement of threaded nut are shown for illustration
purposes only.
SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch)
Siemens FI 01 · 2015
4/255
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna
Hygienic encapsulated antenna (DN 50 aseptic clamp to DIN 11864-1)
50.0
(2.00)
1/2" NPT cable entry (or alternatively, M20
cable gland)
Threaded cover
4
167.0
(6.57)
90.0
(3.54)
153.0
(6.02)
Enclosure
178.0
(7.01)
Retaining
collar
Threaded nut
274.2
(10.80)
225.7
(8.89)
Sensor
reference
point
Ø44.0
(1.73)
11.0
(0.43)
Ø66.9
(2.63)
Ø72.0
(2.83)
Note: Cut out of process connection and placement of threaded nut are shown for illustration
purposes only.
SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch)
4/256
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna
Hygienic encapsulated antenna (DN 80 aseptic clamp to DIN 11864-1)
50.0
(2.00)
1/2" NPT cable entry (or alternatively, M20
cable gland)
Threaded cover
4
167.0
(6.57)
90.0
(3.54)
153.0
(6.02)
Enclosure
178.0
(7.01)
Retaining
collar
343.4
(13.52)
Threaded nut
291.3
(11.47)
Sensor
reference
point
Ø74.7
(2.94)
Ø98.9
(3.89)
Ø104.0
(4.09)
14.5
(0.57)
Note: Cut out of process connection and placement of threaded nut are shown for illustration
purposes only.
SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch)
Siemens FI 01 · 2015
4/257
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna
Hygienic encapsulated antenna (DN 100 aseptic clamp to DIN 11864-1)
50.0
(2.00)
1/2" NPT cable entry (or alternatively, M20
cable gland)
Threaded cover
4
167.0
(6.57)
90.0
(3.54)
153.0
(6.02)
Enclosure
178.0
(7.01)
Retaining
collar
343.4
(13.52)
Threaded nut
291.3
(11.47)
Sensor
reference
point
Ø74.7
(2.94)
14.5
(0.57)
Ø118.9
(4.68)
Ø124.0
(4.88)
Note: Cut out of process connection and placement of threaded nut are shown for illustration
purposes only.
SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch)
4/258
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna
Hygienic encapsulated antenna (DN 50 aseptic flange to DIN 11864-2)
50.0
(2.00)
1/2" NPT cable entry
(or alternatively, M20 cable gland)
Threaded cover
4
167.0
(6.57)
153.0
(6.02)
90.0
(3.54)
Enclosure
178.0
(7.01)
Retaining
collar
274.2
(10.80)
225.7
(8.89)
Flange
Sensor
reference
point
Ø44.0
(1.73)
11.0
(0.43)
Ø63.0
(2.48)
Ø94.5
(3.72)
Note: Cut out of process connection and flange are shown for illustration purposes only.
SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch)
Siemens FI 01 · 2015
4/259
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna
Hygienic encapsulated antenna (DN 80 aseptic flange to DIN 11864-2)
50.0
(2.00)
1/2" NPT cable entry
(or alternatively, M20 cable gland)
Threaded cover
4
167.0
(6.57)
153.0
(6.02)
90.0
(3.54)
Enclosure
178.0
(7.01)
Retaining
collar
343.2
(13.51)
291.2
(11.46)
Flange
Sensor
reference
point
Ø74.7
(2.94)
Ø94.5
(3.72)
Ø133.0
(5.24)
14.5
(0.57)
Note: Cut out of process connection and flange are shown for illustration purposes only.
SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch)
4/260
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna
Hygienic encapsulated antenna (DN 100 aseptic flange to DIN 11864-2)
50.0
(2.00)
1/2" NPT cable entry
(or alternatively, M20 cable gland)
Threaded cover
4
167.0
(6.57)
153.0
(6.02)
90.0
(3.54)
Enclosure
Retaining
collar
178.0
(7.01)
343.2
(13.51)
291.2
(11.46)
Flange
Sensor
reference
point
Ø74.7
(2.94)
14.5
(0.57)
Ø113.5
(4.47)
Ø159.0
(6.26)
Note: The cut out of the process connection and the flange are shown for illustration purposes
only.
SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch)
Siemens FI 01 · 2015
4/261
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna
Hygienic encapsulated antenna (DN 50 aseptic clamp to DIN 11864-3)
50.0
(2.00)
1/2" NPT cable entry
(or alternatively, M20 cable gland)
Threaded cover
4
167.0
(6.57)
153.0
(6.02)
90.0
(3.54)
Enclosure
178.0
(7.01)
Retaining
collar
273.7
(10.78)
225.2
(8.87)
Process
connection
Ø44.0
(1.73)
Ø63.0
(2.48)
Ø77.5
(3.05)
11.0
(0.43)
Note: Cut out of process connection is shown for illustration purposes only.
SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch)
4/262
Siemens FI 01 · 2015
Sensor
reference
point
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna
Hygienic encapsulated antenna (DN 80 aseptic clamp to DIN 11864-3)
50.0
(2.00)
1/2" NPT cable entry
(or alternatively, M20 cable gland)
Threaded cover
4
167.0
(6.57)
153.0
(6.02)
90.0
(3.54)
Enclosure
178.0
(7.01)
Retaining
collar
343.2
(13.51)
291.2
(11.46)
Process
connection
Ø74.7
(2,94)
14.5
(0.57)
Ø94.5
(3.72)
Ø106.0
(4.17)
Sensor
reference
point
Note: Cut out of process connection is shown for illustration purposes only.
SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch)
Siemens FI 01 · 2015
4/263
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna
Hygienic encapsulated antenna (DN 100 aseptic clamp to DIN 11864-3)
50.0
(2.00)
1/2" NPT cable entry
(or alternatively, M20 cable gland)
Threaded cover
4
167.0
(6.57)
153.0
(6.02)
90.0
(3.54)
Enclosure
178.0
(7.01)
Retaining
collar
343.2
(13.51)
291.2
(11.46)
Process
connection
Sensor
reference
point
Ø74.7
(2.94)
14.5
(0.57)
Ø113.5
(4.47)
Ø130.0
(5.12)
Note: Cut out of process connection is shown for illustration purposes only.
SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch)
4/264
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna
Hygienic encapsulated antenna (Tuchenhagen Type F, 50 mm)
50.0
(2.00)
1/2" NPT cable entry
(or alternatively, M20 cable gland)
Threaded cover
4
167.0
(6.57)
153.0
(6.02)
90.0
(3.54)
Enclosure
178.0
(7.01)
Retaining
collar
276.7
(10.89)
232.7
(9.16)
Process
connection
Sensor
reference
point
Ø50.0
(2.00)
Ø66.0
(2.60)
6.5
(0.26)
SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch)
Siemens FI 01 · 2015
4/265
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna
Hygienic encapsulated antenna (Tuchenhagen Type N, 68 mm)
50.0
(2.00)
1/2" NPT cable entry
(or alternatively, M20 cable gland)
Threaded cover
4
167.0
(6.57)
153.0
(6.02)
90.0
(3.54)
Enclosure
178.0
(7.01)
Retaining
collar
274.2
(10.80)
225.5
(8.88)
Process
connection
Sensor
reference
point
Ø 68.0
(2.68)
Ø84.0
(3.31)
SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch)
4/266
Siemens FI 01 · 2015
11.2
(0.44)
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna
■ Schematics
Connect the wires to the
terminals as shown: the
polarity is identified on the
terminal block.
Gland
Hand Programmer
Shield for HART,
PROFIBUS PA , and
FOUNDATION Fieldbus
Intrinsically Safe
versions only.
4
Part number:
7ML1930-1BK
Notes:
1. DC terminal shall be supplied from a source providing electrical isolation between the input and output, to meet the applicable
safety requirements of IEC 61010-1.
2. All field wiring must have insulation suitable for rated input voltages.
3. Use shielded twisted pair cable (14 ... 22 AWG) for HART version.
4. Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes.
SITRANS LR250 connections
Siemens FI 01 · 2015
4/267
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Specials
■ Selection and ordering data
SITRANS LR250 hygienic encapsulated Specials
SITRANS LR250 hygienic encapsulated Specials
Article No.
Spare Lens Kits (Lens and O-ring)
4
Kit, 2 inch, ISO2852, HEA, Lens, silicone
secondary O-ring
Kit, 3 inch, ISO2852, HEA, Lens, silicone
secondary O-ring
Kit, 4 inch, ISO2852, HEA, Lens, silicone
secondary O-ring
A5E32572731
A5E32572745
A5E32572747
Kit, DN 50, DIN11851, HEA, Lens, silicone
secondary O-ring
Kit, DN 80, DIN11851, HEA, Lens, silicone
secondary O-ring
Kit, DN 100, DIN11851, HEA, Lens, silicone
secondary O-ring
A5E32572758
Kit, DN 50, DIN11864-1, HEA, Lens, silicone
secondary O-ring
Kit, DN 80, DIN11864-1, HEA, Lens, silicone
secondary O-ring
Kit, DN 100, DIN11864-1, HEA, Lens, silicone
secondary O-ring
A5E32572773
Kit, DN 50, DIN11864-2/3, HEA, Lens, silicone
secondary O-ring
Kit, DN 80, DIN11864-2/3, HEA, Lens, silicone
secondary O-ring
Kit, DN 100, DIN11864-2/3, HEA, Lens, silicone
secondary O-ring
A5E32572785
A5E32572770
A5E32572772
A5E32572779
A5E32572782
A5E32572790
A5E32572791
Kit, Tuchenhagen, Type F, HEA, Lens, silicone
secondary O-ring
A5E32572794
Kit, Tuchenhagen, Type N, HEA, Lens, silicone
secondary O-ring
A5E32572795
Accessories (customer side process connection and FKM and EPDM seal for each size and
type)
Kit DN 50 DIN 11864-1 GS Form A tank connection, EPDM Seal Class II
Kit, DN 80 DIN 11864-1 GS Form A tank connection, EPDM Seal Class II
Kit, DN 100 DIN 11864-1 GS Form A tank connection, EPDM Seal Class II
A5E32910638
Kit DN 50 DIN 11864-1 GS Form A tank connection, FKM Seal Class I
Kit, DN 80 DIN 11864-1 GS Form A tank connection, FKM Seal Class I
Kit, DN 100 DIN 11864-1 GS Form A tank connection, FKM Seal Class I
A5E32910658
Kit 2" ISO 2852 tank connection, Clamp,
Cleanable EPDM Seal Class II
A5E32910686
4/268
Siemens FI 01 · 2015
Article No.
Kit 3" ISO 2852 tank connection, Clamp,
Cleanable EPDM Seal Class II
Kit 4" ISO 2852 tank connection, Clamp,
Cleanable EPDM Seal Class II
Kit DN 50 DIN 11851 SC tank connection,
EPDM Seal Class II11)
For "Electronics Head only" follow the standard
configuration and choose YY option on positions 9 and 10 of the full part number.
For example: 7ML5433-1YY20-1AA0 will order
an electronics head for the following:
EHEDG EL Class 1 approval, 4 ... 20mA HART,
M20 cable entries, General purpose Haz Loc
approval, pressure rating as per manual.
A5E32910649
A5E32910657
A5E32910671
A5E32910681
A5E32910697
A5E32910708
A5E32910746
Kit DN 80 DIN 11851 SC tank connection,
EPDM Seal Class II11)
Kit DN 100 DIN 11851 SC tank connection,
EPDM Seal Class II11)
Kit DN 50 DIN 11851 SC tank connection,
FKM Seal Class II
A5E32910771
Kit DN 80 DIN 11851 SC tank connection,
FKM Seal Class II
Kit DN 100 DIN 11851 SC tank connection,
FKM Seal Class II
Kit DN 50 DIN 11864-2 Form A tank connection,
M8 Hardware (nut/bolt/washer),
EPDM Seal Class II
A5E32910789
A5E32910780
A5E32910784
A5E32910790
A5E32910791
Kit DN 80 DIN 11864-2 Form A tank connection,
M10 Hardware (nut/bolt/washer),
EPDM Seal Class II
Kit DN 100 DIN 11864-2 Form A tank connection,
M10 Hardware (nut/bolt/washer),
EPDM Seal Class II
Kit DN 50 DIN 11864-2 Form A tank connection,
M8 Hardware (nut/bolt/washer), FKM Seal Class I
A5E32910793
Kit DN 80 DIN 11864-2 Form A tank connection,
M10 Hardware (nut/bolt/washer), FKM Seal Class I
Kit DN 100 DIN 11864-2 Form A tank connection,
M10 Hardware (nut/bolt/washer), FKM Seal Class I
Kit DN 50 DIN 11864-3 Form A tank connection,
Clamp, EPDM Seal Class II
A5E32910809
Kit DN 80 DIN 11864-3 Form A tank connection,
Clamp, EPDM Seal Class II
Kit DN 100 DIN 11864-3 Form A tank connection,
Clamp, EPDM Seal Class II
Kit DN 50 DIN 11864-3 Form A tank connection,
Clamp, FKM Seal Class I
A5E32910799
A5E32910805
A5E32910812
A5E32910813
A5E32910814
A5E32910815
A5E32910816
Kit DN 80 DIN 11864-3 Form A tank connection,
Clamp, FKM Seal Class I
Kit DN 100 DIN 11864-3 Form A tank connection,
Clamp, FKM Seal Class I
Kit Type F, Tuchenhagen, Clamp, EPDM Seal Class
II (EHEDG only) - no tank connection
A5E32910817
Kit Type N, Tuchenhagen, Clamp, EPDM Seal
Class II (EHEDG only) - no tank connection
Kit Type F, Tuchenhagen, Clamp, FKM Seal Class I
(EHEDG only) - no tank connection
Kit Type N, Tuchenhagen, Clamp, FKM Seal
Class I (EHEDG only) - no tank connection
A5E33489543
11)
A5E32910818
A5E33489537
A5E33489828
A5E33489830
Class II for low fat applications when EPMD seal used on DIN 11851.
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR260
■ Overview
■ Configuration
Min. clearance:
10 (0.4)
Mounting on
a nozzle
4
Min. 1 000 (39)
Installation
SITRANS LR260 is a 2-wire 25 GHz pulse radar level transmitter
for continuous monitoring of solids and liquids in storage vessels
including extreme levels of dust and high temperatures,
to a range of 30 m (98.4 ft).
■ Benefits
Emission
cone
• Graphical local user interface (LUI) makes operation simple
with plug-and-play setup using the intuitive Quick Start Wizard
• LUI displays echo profiles for diagnostic support
• 25 GHz high frequency allows for small horn antennas
mounted easily in nozzles
• Communication using HART or PROFIBUS PA
• Process Intelligence signal processing for improved
measurement reliability and Auto False-Echo Suppression of
fixed obstructions
• Programming using infrared Intrinsically Safe handheld
programmer or SIMATIC PDM
Beam angle:
2" horn = 15°
3" horn = 10°
4" horn = 8°
■ Application
SITRANS LR260 includes a graphical local user interface (LUI)
that improves setup and operation using an intuitive Quick Start
Wizard, and echo profile displays for diagnostic support.
Start-up is easy using the Quick Start wizard with a few parameters required for basic operation.
Positioning with
easy Aimer
SITRANS LR260’s unique design allows safe and simple programming using the Intrinsically Safe handheld programmer
without having to open the instrument’s lid.
SITRANS LR260 measures virtually any solids material to a
range of 30 m (98.4 ft).
• Key Applications: cement powder, plastic powder/pellets,
grain, flour, coal, solids and liquids bulk storage vessels,
and other applications.
SITRANS LR260 installation, dimensions in mm (inch)
Siemens FI 01 · 2015
4/269
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR260
■ Technical specifications
Design
Mode of operation
Measuring principle
Pulse radar level measurement
Frequency
K-band (25.0 GHz)
Minimum detectable distance
0.05 m (2 inch) from end of horn
Maximum measuring range 1)
4
• Solids
• 2" horn: 10 m (32.8 ft)
• 3" horn: 20 m (65.6 ft)
• 4" horn: 30 m (98.4 ft)
• Liquids
• 2" horn: 20 m (65.6 ft)
• 3" horn: 30 m (98.4 ft)
• 4" horn: 30 m (98.4 ft)
Output - HART
Power
Fail signal
Load
Output - PROFIBUS PA
Performance (according to reference conditions IEC60770-1)
Maximum measured error (including
hysteresis and non-repeatability)
• 4 ... 20 mA (± 0.02 mA accuracy)
• Nominal 24 V DC (max. 30 V DC)
• 3.6 mA ... 23 mA;
or last value 230 ... 600 
• Per IEC 61158-2
• 15.0 mA
• Profile version 3.01, Class B
Enclosure
• Construction
• Conduit entry
Degree of protection
Weight
Display (local)
Flange and horn (easy aimer model)
• Material
• Horn antenna
Process connections
• Universal flanges 2)
Rated operating conditions
Installation conditions
• Location
Indoor/outdoor
Ambient conditions (enclosure)
• Ambient temperature
• Installation category
• Pollution degree
-40 ... +80 °C (-40 ... +176 °F)
I
4
• Materials
Process temperature
Process pressure
r > 1.6, antenna and application
dependent
-40 ... +200 °C (-40 ... +392 °F)
• 0.5 bar g (7.25 psi g) maximum
• 3 bar g (43.5 psi g) optional with
80 °C (176 °F) temperature max
Siemens FI 01 · 2015
2" NPT (ASME B1.20.1),
R (BSPT, EN 10226-1) or
G (BSPP, EN ISO 228-1)
316L/1.4404 or 316L/1.4435 stainless
steel PTFE emitter
Certificates and approvals
CSAUS/C, CE, FM
Radio
Europe (R&TTE), FCC,
Industry Canada, RCM
Hazardous
CSA/FM Class II, Div. 1,
Groups E, F, G, Class III
ATEX II 1D, 1/2D, 2D Ex ta IIIC
T100 ºC Da
IECEx/ATEX II 1 GD Ex ia IIC T4 Ga,
Ex ta IIIC T100 ºC Da
CSA/FM Class I, II, III, Div. 1,
Groups A, B, C, D, E, F, G
SABS ARP0108 Ex ia IIC T4 Ga
Programming
Intrinsically Safe Siemens handheld
programmer
• Approvals for handheld
programmer
Handheld communicator
PC
Display (local)
4/270
2 inch/50 mm, 3 inch/80 mm,
4 inch/100 mm, 6 inch/150 mm
General
Medium conditions
Dielectric constant r
304 stainless steel
2" horn
3" horn
4" horn
Mechanical (Threaded Connection
model)
• Threaded connection
• 25 mm (1 inch) from minimum
detectable distance to 300 mm
(11.8 inch)
• Remainder of range = 10 mm
(0.39 inch) or 0.1 % of
spa(whichever is greater)
Aluminum, polyester powder-coated
2 x M20x1.5 or 2 x ½" NPT
Type 4X/NEMA 4X, Type 6/ NEMA 6,
IP67, IP68
< 8.14 kg (17.9 lb) including 4" flange
and standard Easy Aimer with 4" horn
antenna
Graphic LCD, with bar graph representing level
Infrared receiver
IS model:
ATEX II 1GD Ex ia IIC T4 Ga
Ex iaD 20 T135 °C Ta = -20 ... +50 °C
CSA/FM Class I, II, and III, Div. 1,
Groups A, B, C, D, E, F, G,
T6 Ta = 50 °C
HART communicator 375
SIMATIC PDM
Graphic local user interface including
quick start wizard and echo profile
displays
1)
From sensor reference point
2)
Universal flange mates with EN 1092-1 (PN 16)/ASME B16.5 (150 lb)/
JIS 2220 (10K) bolt hole pattern
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR260
Selection and Ordering data
Article No.
Selection and Ordering data
SITRANS LR260
2-wire, 25 GHz pulse radar level transmitter for continuous monitoring of solids to a range of 30 m
(98.4 ft).
Order handheld programmer separately
7ML54270 7 7 7 0 - 77 7 7
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Process connection
Universal flat faced flange fits ANSI/DIN/JIS
flanges, Easy Aimer with integral (Easy Aimer ball)
2 inch/50 mm
3 inch/80 mm
A
B
4 inch/100 mm
6 inch/150 mm
C
D
Threaded connection
2" NPT (ASME B1.20.1) (tapered thread)1)2)5)
thread)1)2)5)
R 2" [(BSPT), EN 10226-1] (tapered
G 2" [(BSPT), EN ISO 228-1] (parallel thread)1)2)5)
E
F
G
Order code
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 27 characters); specify in plain text
Y15
Manufacturer's test certificate: M to DIN 55350,
Part 18 and to ISO 9000
Inspection Certificate Type 3.1 per EN 102044)
C11
Operating Instructions for HART/mA device
Article No.
English
German
Note: The Operating Instructions should be
ordered as a separate line item on the order.
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
7ML1998-5KE03
C12
A5E34942821
A5E32106122
Operating Instructions for PROFIBUS PA device
Antenna
2" Horn antenna, fits 50 mm or 2" nozzles1)
A
2" Horn antenna with 100 mm extension1)
2" Horn antenna with 200 mm extension1)
B
C
2" Horn antenna with 500 mm extension1)2)
2" Horn antenna with 1 000 mm extension1)2)
D
E
3" Horn antenna, fits 80 mm or 3" nozzles3)
3" Horn antenna with 100 mm extension3)
F
G
3" Horn antenna with 200 mm extension3)
3" Horn antenna with 500 mm extension2)3)
H
J
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F), HART
7ML1930-1AP
3" Horn antenna with 1 000 mm extension2)3)
4" Horn antenna, fits 100 mm or 4" nozzles
K
L
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F), PROFIBUS PA
7ML1930-1AQ
4" Horn antenna with 100 mm extension
4" Horn antenna with 200 mm extension
M
N
Handheld programmer, Infrared, Intrinsically Safe
7ML1930-1BK
Dust cap, PTFE, for 2 inch/50 mm horn
7ML1930-1DE
4" Horn antenna with 500 mm extension2)
4" Horn antenna with 1 000 mm extension2)
P
Q
Dust cap, PTFE, for 3 inch/75 mm horn
7ML1930-1BL
Dust cap, PTFE, for 4 inch/100 mm horn
7ML1930-1BM
HART modem/USB
(for use with a PC and SIMATIC PDM)
7MF4997-1DB
SITRANS RD100, loop powered display see Chapter 7
7ML5741-...
SITRANS RD200, universal input display with
Modbus conversion - see Chapter 7
7ML5740-...
SITRANS RD300, dual line display with totalizer
and linearization curve and Modbus conversion see Chapter 7
7ML5744-...
SITRANS RD500 web, universal remote monitoring
solution for instrumentation - see Chapter 7
7ML5750-...
English
German
Note: The Operating Instructions should be
ordered as a separate line item on the order.
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
A5E34957877
A5E32114443
Accessories
Purge (self cleaning) connection
No purge connection
0
Purge connection
1
Output/communication
4 ... 20 mA, HART
PROFIBUS PA
7ML1998-5KF03
0
1
Cable inlet
2 x M20x1.5
A
2 x ½" NPT
B
Note: Polymeric cable glands will be provided with
M20 devices.
Approvals
For applicable back up point level switch see point level measurement section
General purpose, CSAUS/C, FM, Industry Canada,
FCC, CE, R&TTE, RCM
A
CSA/FM Class II, Div. I, Groups E, F, G, Class III,
Industry Canada, FCC, RCM
B
Note: Products shipped with plastic cable gland,
rated to -20 °C. If -40 °C rating required,
then metallic cable gland is recommended.
ATEX II 1D, 1/2D, 2D Ex ta IIIC T100 ºC Da, CE,
R&TTE, RCM, INMETRO
Non-incendive, CSA/FM Class I, Div. 2, Groups A,
B, C, D, Industry Canada, FCC, RCM
Intrinsically safe, IECEx/ATEX II 1 GD Ex ia IIC T4
Ga, Ex ta IIIC T100 ºC Da, R&TTE, RCM
Intrinsically safe, CSA/FM Class I, II, III, Div. 1,
Groups A, B, C, D, E, F, G, Industry Canada, FCC,
RCM
Intrinsically safe, South Africa ARP0108 Ex ia IIC T4
Ga
Pressure rating
C
1)
Maximum measurement range 10 m (32.8 ft) solids or 20m (65.6ft) liquids
2)
Available with Purge option 0 only
3)
Maximum measurement range 20 m (65.6 ft) solids or 30m (98.4ft) liquids
4)
Available with pressure option 0 only
5)
Available with Antenna Options A, B, F, G, L, and M only
6)
Available with pressure option 0 only
Rating per Pressure/Temperature curves in
manual6)
0.5 bar g (7.25 psi g) maximum
D
E
F
G
0
1
Siemens FI 01 · 2015
4/271
4
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR260
■ Characteristic curves
Ambient temperature (°C)
Maximum flange and process temperatures versus allowable ambient temperature
90
80
70
60
50
40
30
20
10
4
0
0
50
100
150
200
250
Process flange surface temperature (°C)
SITRANS LR260 Ambient/Process Flange Surface Temperature Curve
■ Dimensional drawings
Nameplate
268 (10.6)
Enclosure/electronics
Optional purge connection
with factory-installed
1/8" NPT plug
Universal slotted flange
Process
device tag
Optional extension
100/200/500/1000
(3.93/7.87/19.68/39.37)
Horn
Optional PTFE dust cap
Clamp screw
49 (1.9)
74.5 (2.9)
97.5 (3.8)
SITRANS LR260, dimensions in mm (inch)
4/272
Siemens FI 01 · 2015
2" horn: 163 (6.4)
3" horn: 228 (9.0)
4" horn: 285 (11.2)
Sensor
reference
point
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR260
SITRANS LR260
½" NPT cable entry
(or alternatively,
M20 cable gland)
50
(2.0)
Threaded cover
167 (6.6)
90 (3.5)
154 (6.1)
159
(6.26)
196 (7.7)
Enclosure/
electronics
281 (11.1)
Retaining
collar
28 (1.1)*
Optional
100 (3.93)
Horn
Extension
4
Process
device tag
Sensor
reference
point
Horn
Horn
O.D.
Antenna
Type
47.8 (1.88)
Beam angle
Measurement
range
180 (7.09)
15 degrees
20 m (65.6 ft)
20 m (65.6 ft)
20 m (65.6 ft)
Height to sensor reference point
Antenna O.D.
1-1/2" threaded
connection
2" horn
Horn
O.D.
N/A
2" threaded
connection
166 (6.55)
3" threaded
connection
3" horn
74.8 (2.94)
N/A
199 (7.85)
213 (8.39)
10 degrees
4" horn
94.8 (3.73)
N/A
254 (10)
268 (10.55)
8 degrees
SITRANS LR260, dimensions in mm (inch)
■ Schematics
Connect the wires to the
terminals as shown: the
polarity is identified on the
terminal block.
Gland
Hand programmer
Shield for HART and
PROFIBUS PA
intrinsically safe
versions only.
Part number:
7ML1930-1BK
Notes:
1. DC terminal shall be supplied from a source providing electrical isolation between the input and output, to meet the applicable
safety requirements of IEC 61010-1.
2. All field wiring must have insulation suitable for rated input voltages.
3. Use shielded twisted pair cable (14 ... 22 AWG) for HART version.
4. Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes.
SITRANS LR260 connections
Siemens FI 01 · 2015
4/273
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR460
■ Overview
■ Application
SITRANS LR460 provides excellent results even during conditions of extreme dust. The integral Easy Aimer included on the
SITRANS LR460 allows for easy positioning for optimum measurement on solids.
Process Intelligence onboard SITRANS LR460 means advanced
signal processing is harnessed for reliable operation on both
simple and difficult solids application.
SITRANS LR460 features a robust enclosure, flange and horn
components. It is virtually unaffected by atmospheric or temperature conditions within the vessel.
An optional dust cap is available for sticky solids. Optional air
purging is also available for extremely sticky applications.
Safe on-site local programming is simple using the Intrinsically
Safe handheld programmer. SIMATIC PDM can be used for easy
remote programming using HART or PROFIBUS PA.
4
The SITRANS LR460 is a 4-wire, 24 GHz FMCW radar level transmitter with extremely high signal-to-noise ratio and advanced
signal processing for continuous monitoring of solids up to
100 m (328 ft). It is ideal for measurement in extreme dust.
The characteristics of 24 GHz and high signal-to-noise ratio contribute to exceptional signal reflection, regardless of the dielectric value of the medium.
• Key Applications: long-range dusty applications,
cement powder, fly-ash, coal, flour, grain, plastics
■ Benefits
• Process Intelligence for advanced signal processing and
quick and easy adjustment
• Self-guided quick start wizard for plug and play start-up
• 24 GHz provides superior reflective properties on solids
surfaces
• 100 m (328 ft) range for long-range and difficult applications
• Easy Aimer optimizes signal quality on sloped surfaces
• Programming using infrared Intrinsically Safe handheld
programmer or with SIMATIC PDM or HART handheld device
■ Configuration
Beam angle
Mounting unit on vessel
Positioning with
Easy Aimer
Installation in
mounting nozzle
4 inch
horn
3 inch
horn
10
(0.39)
8°
11°
Note: For best signal, always use largest horn size possible.
SITRANS LR460 installation, dimensions in mm (inch)
4/274
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR460
■ Technical specifications
Mode of operation
Programming
Measuring principle
FMCW radar level measurement
Frequency
24.2 ... 25.2 GHz FMCW
Measuring range
0.35 ... 100 m (1.15 ... 328.08 ft)
Intrinsically Safe Siemens handheld
programmer (ordered separately)
• Approvals for handheld
programmer
Infrared receiver
Handheld communicator
HART Communicator 375
PC
SIMATIC PDM
Display (local)
Alphanumeric LCD for readout and
entry
Power supply
100 ... 230 V AC ± 15 % (50/60 Hz),
6 W (12 VA)
Output
Analog output (HART)
• Signal range
• Load
• Fail-safe
Optically isolated
Max. 600 
mA signal programmable as high,
low or hold (LOE)
Communication
HART, optional PROFIBUS PA
Digital output
Relay, NC or NO function,
max. 50 V DC, max. 200 mA,
rating 5 W
PROFIBUS PA protocol
Layer 1 and 2, Class A, Profile 3.01
Performance (Reference conditions
according to IEC 60770-1)
• Non-linearity
Greater of 25 mm (1 inch) or 0.25 %
of span (including hysteresis and
non-repeatability), over the full ambient temperature range
 10 mm (0.4 inch)
• Non-repeatability
Rated operating conditions
• Amb. temperature for enclosure
• Location
• Installation category
• Pollution degree
IS model with ATEX II 1G EEx ia IIC
T4, CSA/FM Class I, Div. 1,
Groups A, B, C, D T6 at max. ambient
temperature of 40 °C (104 °F)
or
24 V DC +25/-20 %, 6 W (optional)
Certificates and approvals
General
CSAUS/C, CE, FM, RCM
Radio
European Radio (R&TTE),
Industry Canada, FCC, RCM
Hazardous Areas
CSA/FM Class II, Div. 1,
Groups E, F and G, Class III
ATEX II 1D, 1/2 D, 2D T85 °C
INMETRO ExtD A20 IP67 T85 °C
-40 ... +65 °C (-40 ... +149 °F)
Indoor/outdoor
II
4
Medium conditions
Dielectric constant
r > 1.4
Process temperature range
-40 ... +200 °C (-40 ... +392 °F)
Vessel pressure
0.5 bar g (7.25 psi g) maximum
GOST Ex DIP A20 Ta 85 °C IP67
Optional equipment
Dust cap
PTFE
Air purge connection
1/8" NPT
Design
Weight
Materials
• Enclosure
• Degree of protection
• Cable inlet
Process connections
• Universal flanges, 304 stainless
steel, flat faced, with integral Easy
Aimer
Approx. 6.1 kg (13.4 lb) with 3 inch
universal flange
Die-cast aluminum, painted
IP67/Type 4X/NEMA 4X/Type 6/
NEMA 6
2x M20x1.5 or ½" NPT
3 inch/80 mm, 4 inch/100 mm,
6 inch/150 mm (mates with flange
EN 1092-1, ASME B16.5, or
JIS B2238 bolt pattern), 0.5 bar g
(7.25 psi g) max. pressure
Siemens FI 01 · 2015
4/275
4
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR460
Selection and Ordering data
Article No.
Selection and Ordering data
SITRANS LR460
4-wire, 24 GHz FMCW radar level transmitter with
extremely high signal-to-noise ratio and advanced
signal processing for continuous monitoring of
solids up to 100 m (328 ft). It is ideal for
measurement in extreme dust.
Order handheld programmer separately
7ML5426-
Further designs
0 7 7 7 0 - 777 0
Please add "-Z" to Article No. and specify Order
code(s).
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Process connection
Universal, flat faced, 0.5 bar g (7.25 psi g)
maximum with integral Easy Aimer ball
3 inch (80 mm)
4 inch (100 mm)
6 inch (150 mm)
4
Antenna
3" horn antenna, fits 80 mm (3 inch) nozzles
3" horn antenna, fits 80 mm (3 inch) nozzles with
100 mm extension
3" horn antenna, fits 80 mm (3 inch) nozzles with
200 mm extension
A
B
C
A
B
Order code
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 27 characters); specify in plain text
Y15
Manufacturer's test certificate: M to DIN 55350,
Part 18 and to ISO 9000
C11
Operating Instructions
Article No.
English
7ML1998-5JM02
French
7ML1998-5JM11
German
7ML1998-5JM32
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
A5E32007360
Accessories
C
Handheld programmer, Infra-red, Intrinsically Safe,
EEx ia
7ML5830-2AJ
3" horn antenna, fits 80 mm (3 inch) nozzles with
500 mm extension1)
3" horn antenna, fits 80 mm (3 inch) nozzles with
1 000 mm extension1)
4" horn antenna, fits 100 mm (4 inch) nozzles
D
Dust cap, PTFE, for 3 inch/80 mm horn
7ML1930-1BL
Dust cap, PTFE, for 4 inch/100 mm horn
7ML1930-1BM
HART modem/USB
(for use with a PC and SIMATIC PDM)
7MF4997-1DB
4" horn antenna, fits 100 mm (4 inch) nozzles with
100 mm extension
4" horn antenna, fits 100 mm (4 inch) nozzles with
200 mm extension
4" horn antenna, fits 100 mm (4 inch) nozzles with
500 mm extension1)
G
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F), HART1)
7ML1930-1AP
H
One metallic cable gland M20x1.5,
7ML1930-1AQ
rated -40 ... +80 °C (-40 ... +176 °F), PROFIBUS PA1)
J
SITRANS RD100, loop powered display see Chapter 7
7ML5741-...
4" horn antenna, fits 100 mm (4 inch) nozzles with
1 000 mm extension1)
K
SITRANS RD200, universal input display with
Modbus conversion - see Chapter 7
7ML5740-...
SITRANS RD300, dual line display with totalizer
and linearization curve and Modbus conversion see Chapter 7
7ML5744-...
SITRANS RD500 web, universal remote monitoring
solution for instrumentation - see Chapter 7
7ML5750-...
Purge (self-cleaning) connection
No purge connection
Purge connection
Output/Communication
4 ... 20 mA, HART
PROFIBUS PA
E
F
0
1
0
1
For applicable back up point level switch see point level measurement section
Power supply/cable inlet
100 ... 230 V AC
• 2 x M20x1.5
• 2 x ½" NPT
A
B
24 V DC
• 2 x M20x1.5
• 2 x ½" NPT
C
D
Approvals
General Purpose, CSAUS/C, Industry Canada, FM,
FCC, CE and R&TTE, RCM
CSA/FM Class II, Div. 1, Groups E, F, and G,
Class III
ATEX II 1/2 D T6, CE, R&TTE
1)
Available with Purge option 0 only
4/276
Siemens FI 01 · 2015
1)
A
B
C
Product shipped with plastic cable gland, rated to -20 °C.
If -40 °C rating required, then metallic cable gland is recommended.
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR460
■ Dimensional drawings
SITRANS LR460 (7ML5426)
204 (8.0)
Connection
cover
Electronics
cover
287 (11.29)
Purge connection
Easy Aimer ball locking bolts
Universal slotted flange
Optional horn
extension(s)
100/200/
500/1 000
(3.93/7.87/
19.68/39.37)
4
Reference
point
228 (8.97)
285 (11.22)
Horn antenna
74.5
(2.93)
97.5 (3.84)
SITRANS LR460, dimensions in mm (inch)
Siemens FI 01 · 2015
4/277
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR460
■ Schematics
AC version
Earth terminal
Cable clamp
4
Hand programmer
DC version
Earth terminal
Cable clamp
HART
HART
SITRANS LR460
Part number:
7ML5830-2AJ
Earth terminal
Cable clamp
Earth terminal
Cable clamp
PROFIBUS PA
PROFIBUS PA
Notes
•
•
•
•
•
Recommended torque on terminal clamping screws, 0.5 ... 0.6 Nm
4 ... 20 mA, PROFIBUS PA, DC input circuits, 14 ... 20 AWG, shielded copper wire
AC input circuit, min. 14 AWG copper wire
All field wiring must have insulation suitable for at least 250 V
The equipment must be protected by a 15 A fuse or circuit breaker in the building installation
SITRANS LR460 connections
4/278
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR260/LR460 Specials
■ Selection and ordering data
SITRANS LR260/LR460 Specials
SITRANS LR260/LR460 Specials
Article No.
Process connection
part kits - non-pressure-rated
Article No.
Enclosure with electronics (LR460)
LR260/LR460,100 mm extension for horn antenna,
no purge1)
A5E01087872
LR260/LR460, 200 mm extension for horn antenna,
no purge1)
A5E01091262
LR260/LR460,100 mm extension for horn antenna
with purge1)
A5E01261979
LR260/LR460, 200 mm extension for horn antenna
with purge1)
A5E01261981
LR260/LR460, horn 2", no purge, no emitter1)
A5E02083905
LR260/LR460, horn 3", no purge, no emitter1)
A5E01623511
LR260/LR460, horn 4", no purge, no emitter1)
A5E01623512
LR260/LR460, horn 2", with purge, no emitter1)
A5E02083906
LR260/LR460, horn 3", with purge, no emitter1)
A5E01623513
LR260/LR460, horn 4", with purge, no emitter1)
A5E01623514
LR260/LR460, 3" universal flat faced flange1)
A5E02303897
LR260/LR460, 4" universal flat faced flange1)
A5E01259467
LR260/LR460, 6" universal flat faced flange1)
A5E01261834
LR260/LR460 O-Rings for Easy Aimer1)
A5E01261836
LR460 enclosure with board stack,
HART communication, AC power,
M20 cable inlet, approval option A,
no process connection
A5E02182085
LR460 enclosure with board stack,
PROFIBUS PA communication, AC power,
M20 cable inlet, approval option A,
no process connection
A5E02212422
LR460 enclosure with board stack,
HART communication, AC power,
NPT cable inlet, approval option A,
no process connection
A5E02212423
LR460 enclosure with board stack,
PROFIBUS PA communication, AC power,
NPT cable inlet, approval option A,
no process connection
A5E02212424
A5E02212425
A5E02465410
LR460 enclosure with board stack,
HART communication, DC power,
M20 cable inlet, approval option A,
no process connection
A5E02212426
LR260/LR460 purge conversion, 2" horn1)
A5E02083914
LR460 enclosure with board stack,
PROFIBUS PA communication, DC power,
M20 cable inlet, approval option A,
no process connection
LR260/LR460 purge conversion, 3" horn1)
A5E02083915
A5E02083916
LR460 enclosure with board stack,
HART communication, DC power,
NPT cable inlet, approval option A,
no process connection
A5E02212428
LR260/LR460 purge conversion, 4" horn1)
LR460 enclosure with board stack,
PROFIBUS PA communication, DC power,
NPT cable inlet, approval option A,
no process connection
A5E02212429
Kit, Emitter for
LR260/LR4601)
LR260 lid with O-ring
A5E02360694
Purge conversion kit – non-pressure-rated
(no flange or extension included)
Enclosure with electronics
1)
LR260 enclosure with board stack,
HART communication, M20 cable inlet,
approval option A, no process connection
A5E02203605
LR260 enclosure with board stack,
PROFIBUS PA communication,
M20 cable inlet, approval option A,
no process connection
A5E02213423
LR260 enclosure with board stack,
HART communication, NPT cable inlet,
approval option A, no process connection
A5E02165924
LR260 enclosure with board stack,
PROFIBUS PA communication,
NPT cable inlet, approval option A,
no process connection
A5E02213428
Sitrans LR260 enclosure with board stack,
HART communication, NPT cable inlet,
approval option D, no process connection
A5E03934184
Sitrans LR260 enclosure with board stack,
HART communication, M20 cable inlet,
approval option E, no process connection
A5E03934187
LR260 enclosure with board stack,
HART communication, NPT cable inlet,
approval option F, no process connection
A5E03934191
LR260 enclosure with board stack,
PROFIBUS PA communication, M20 cable
inlet, approval option F, no process connection
A5E31820689
4
Available with no pressure rating, 0.5 bar g maximum.
Please contact [email protected] for special requests.
Siemens FI 01 · 2015
4/279
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR560
■ Overview
■ Configuration
Installation
Note:
• Beam angle is the width of the
cone where the energy
density is half of the peak
energy density
Emission
• The peak energy density cone
is directly in front of and
in line with the antenna
• There is signal transmitted
outside of the beam angle;
therefore false targets may be
detected
4°
4
SITRANS LR560 2-wire, 78 GHz FMCW radar level transmitter for
continuous monitoring of solids in silos to a range of 100 m
(329 ft).
■ Benefits
• Rugged stainless steel design for industrial applications
• 78 GHz high frequency provides very narrow beam, virtually
no mounting nozzle noise, and optimal reflection from sloped
solids
• Aimer option to direct beam to area of interest, such as draw
point of cone
• Lens antenna is highly resistant to product build-up
• Air purge connection is included for self-cleaning of
extremely sticky solids
• Local display interface (LDI) allows local programming and
diagnostics
■ Application
SITRANS LR560’s plug and play performance is ideal for most
solids applications, including those with extreme dust and high
temperatures to 200 ºC (392 ºF). Unique design allows safe and
simple programming using the Intrinsically Safe handheld programmer without having to open the instrument’s lid.
SITRANS LR560 includes an optional graphical local display
interface (LDI) that improves setup and operation using an intuitive Quick Start Wizard, and echo profile display for diagnostic
support. Start-up is easy using the Quick Start wizard with a few
parameters required for basic operation.
SITRANS LR560 measures practically any solids material to a
range of 100 m (328 ft).
• Key Applications: cement powder, plastic powder/pellets,
grain, coal, wood powder, fly ash
4/280
Siemens FI 01 · 2015
Aiming will assist in measuring
material in the cone
SITRANS LR560 installation, dimensions in mm (inch)
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR560
■ Technical specifications
Mode of operation
Power supply
Measuring principle
Radar level measurement
Frequency
78 GHz FMCW
Minimum detectable distance
400 mm (15.75 inch) from sensor
reference point
Maximum measuring range1)
• 40 m (131 ft) version
• 100 m (328 ft) version
Output
• Analog output
• Communications
• Fail-safe
4 ... 20 mA
• HART
• Optional: PROFIBUS PA
• Optional: FOUNDATION Fieldbus
• Programmable as high, low or hold
(Loss of Echo)
• NE43 programmable
4 ... 20 mA/HART
Nominal 24 V DC (max. 30 V DC) with
max. 550 
PROFIBUS PA/FOUNDATION Fieldbus
13.5 mA
9 ... 32 V DC, per IEC 61158-2
Certificates and approvals
General
Radio
Hazardous
• Europe/International
Performance (according to reference conditions IEC60770-1)
• Maximum measured error (including 5 mm (0.2 inch)
hysteresis and non-repeatability)2)
• US/Canada
Rated operating conditions
(according to reference conditions
IEC60770-1)
• China
Installation conditions
• Location
Indoor/outdoor
Ambient conditions (enclosure)
• ambient temperature
• installation category
• pollution degree
-40 ... +80 °C (-40 ... +176 °F)
I
4
Medium conditions
• Dielectric constant r
> 1.6
Process temperature and pressure
See chart below
Design
Enclosure
• Construction
• Conduit entry
• Purge inlet
• Lens material
• Degree of protection
• Weight
• Optional local display interface
316L/1.4404 stainless steel
M20x1.5, or ½" NPT via adapter
1/8" NPT, 30 cfm at max. 100 psi
• 40 m version: PEI
• 100 m version: PEEK
Damage to lens could result from
continuous purging/cleaning due to
abrasive solids. Recommended purging/cleaning only a few seconds
every hour
Type 4X/NEMA 4X, Type 6/NEMA 6,
IP68 with lid closed
3.15 kg (6.94 lb) including 3 inch
flange
Graphic LCD, with bar graph representing level
Process connections
Universal flat-faced flanges3)
Aimer flanges3)
• 3, 4, 6 inch/80, 100, 150 mm,
304 stainless steel
• 3, 4, 6 inch/80, 100, 150 mm,
316L/1.4404 or 316L/1.4435 stainless steel
• Brazil
CSAUS/C, CE, FM
Europe (R&TTE), FCC,
Industry Canada, RCM
IECEx SIR 09.0149X
ATEX II 1D, 1/2D, 2D
Ex ta IIIC T139 ºC Da IP68
ATEX II 3G
Ex nA II T4 Gc
Ex nL IIC T4 Gc
FM/CSA Class II, Div. 1,
Groups E, F, G
Class III T4
FM/CSA Class I, Div. 2,
Groups A, B, C, D, T4
NEPSI
Ex nA II T4
Ex nL IIC T4
DIP A20 TA, T139 ºC, IP68
INMETRO
4
BR-Ex nA/nL II T4 IP68
Programming
Intrinsically Safe Siemens handheld Infrared receiver
programmer
• Approvals for handheld programmer IS model:
ATEX II 1GD Ex ia IIC T4 Ga
Ex iaD 20 T135 °C
Ta = -20 ... +50 °C
CSA/FM Class I, II, and III, Div. 1,
Groups A, B, C, D, E, F, G, T6
Ta = 50 °C
Handheld communicator
HART communicator 375/475
SIMATIC PDM, AMS, PACTware
PC
Display (local)
Graphic local user interface including
quick start wizard and echo profile
displays
1)
From sensor reference point
2)
Under severe EMI/EMC environments per IEC61326-1 or NAMUR NE21,
the device error may increase to a maximum of 25 mm (1 inch)
3)
Universal flange mates with EN 1092-1 (PN16)/ASME B16.5 (150 lb)/
JIS 2220 (10K) bolt hole pattern.
Process temperature and pressure
Version
Stainless steel
Aimer flange:
-1 ... 0.5 bar
Aimer flange:
-1 ... 3.0 bar
40 m
-40 ... +100 °C
(-40 ... +212 °F)
-40 ... +100 °C
(-40 ... +212 °F)
-40 ... +100 °C
(-40 ... +212 °F)
100 m
-40 ... +200 °C
(-40 ... +392 °F)
-40 ... +200 °C
(-40 ... +392 °F)
-40 ... +120 °C
(-40 ... +248 °F)
3, 4, 6 inch/80, 100, 150 mm, polyurethane powder-coated cast aluminum
Siemens FI 01 · 2015
4/281
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR560
Selection and Ordering data
Article No.
Selection and Ordering data
SITRANS LR560
2-wire, 78 GHz FMCW radar level transmitter for
continuous monitoring of solids in silos to a range
of 100 m (329 ft).
Order handheld programmer separately
7ML5440-
Further designs
77 7 0 0 - 77 77
Please add "-Z" to Article No. and specify Order
code(s).
Plug M12 with mating connector1)2)3)
Plug 7/8" with mating connector1)3)4)
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Measurement and process temperature range
40 m (131 ft) max range, -40 ... +100 °C
100 m (329 ft) max range, -40 ... +200 °C
4
¢ 0
¢ 1
Manufacturer's test certificate: M to DIN 55350,
Part 18 and to ISO 9000
¢
¢
¢
A
B
C
Article No.
English
7ML1998-5KB02
German
7ML1998-5KB32
A5E32052143
D
E
F
3 inch/80 mm, painted aluminum, with integral
aimer1)
4 inch/100 mm, painted aluminum, with integral
aimer1)
6 inch/150 mm, painted aluminum, with integral
aimer1)
¢
G
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
¢
H
Operating Instructions for PROFIBUS PA device
¢
J
¢
¢
Pressure rating
0.5 bar g (7.5 psi g) maximum
3 bar g (40 psi g) maximum
¢
¢
Output/communication
4 ... 20 mA, HART
PROFIBUS PA
FOUNDATION Fieldbus
¢
¢
¢
A
B
Approvals
General Purpose, CSAUS/C, Industry Canada, FCC, ¢
CE, R&TTE, RCM
CSA/FM Class I, Div. 2, Groups A, B, C, D, Class II, ¢
Div.1, Groups E, F, G, Class III
Local display interface
Without LDI (local display interface)
With LDI (local display interface)
1)
¢ C11
Operating Instructions for HART device
¢
¢
¢
ATEX II 1 D, ½ D, 2 D, 3G Ex nA/nL, CE, R&TTE,
RCM
¢ A55
Inspection Certificate Type 3.1 per EN 102044)
¢ C12
NAMUR NE43 compliant, device preset to failsafe ¢ N07
< 3.6 mA5)
3 inch/80 mm, 316L stainless steel
4 inch/100 mm, 316L stainless steel
6 inch/150 mm, 316L stainless steel
Enclosure (with cable inlet)
Stainless steel, 1 X ½" NPT
Stainless steel, 1 X M20 x 1.5
(plastic gland included)
¢ A50
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Measuring-point number/identification
(max. 27 characters); specify in plain text
Process connection
Universal flat-faced flange fits ANSI/DIN/JIS
flanges
3 inch/80 mm, 304 stainless steel
4 inch/100 mm, 304 stainless steel
6 inch/150 mm, 304 stainless steel
Order code
¢
¢
¢
English
7ML1998-5LT02
German
7ML1998-5LT32
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
A5E32043113
Operating Instructions for
FOUNDATION Fieldbus device
0
1
A
B
C
English
7ML1998-5LY02
German
7ML1998-5LY32
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
A5E32034712
Accessories
A
B
C
1
2
Rated to 120 ºC max. when used with Pressure rating option 1
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Hand Programmer, Intrinsically safe
7ML1930-1BK
Local display interface
7ML1930-1FJ
Sun Shield Cover
7ML1930-1FK
Housing lid with window
7ML1930-1FL
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F), HART6)
7ML1930-1AP
One metallic cable gland M20x1.5,
7ML1930-1AQ
rated -40 ... +80 °C (-40 ... +176 °F), PROFIBUS PA6)
SITRANS RD100, loop powered display see Chapter 7
7ML5741-...
SITRANS RD200, universal input display with
Modbus conversion - see Chapter 7
7ML5740-...
SITRANS RD300, dual line display with totalizer
and linearization curve and Modbus conversion see Chapter 7
7ML5744-...
SITRANS RD500 web, universal remote monitoring
solution for instrumentation - see Chapter 7
7ML5750-...
For applicable back up point level switch see point level measurement section
1)
2)
3)
4)
5)
6)
Available with Approval option A only
Available with Enclosure option B only
Available with Output/communication options B and C only
Available with Pressure rating option 1 only
Available with Output/communication option A only
Product shipped with plastic cable gland, rated to -20 °C.
If -40 °C rating required, then metallic cable gland is recommended.
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
4/282
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR560
■ Options
Handheld programmer
Sun shield cover
Part number:
7ML1930-1BK
Part number:
7ML1930-1FK
4
SITRANS LR560 handheld programmer and sun shield cover
Siemens FI 01 · 2015
4/283
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR560
■ Characteristic curves
Temperature derating curve
Ambient
temperature
90
80
4
Ambient temperature (°C)
70
Process
temperature
60
50
40
30
40 m
version
100 m
version
20
10
0
50
100
150
200
250
Process temperature (°C)
SITRANS LR560 temperature derating curve
■ Dimensional drawings
Flat flange
3” aimer flange
4 and 6” aimer flange*
Lid lock
Cable gland
Cable gland
Cable gland
176
(6.93)
Grounding lug
Grounding
lug
Purge plug
166.1
(6.54)
Grounding lug
Purge plug
166.1
(6.54)
Purge plug
Process
connection:
3” aimer
flange
Process
connection:
flat flange
110 (4.33)
200 (7.87)
Sensor
reference
point
22.3
(0.92)
110
(4.33)
9.6
(0.38)
Process
connection:
4 and 6”
aimer flange
4”: 229
(9.02)
6”: 285
(11.22)
229
(9.02)
A
110
(4.33)
9.6
(0.38)
10º max.
* C Spanner wrench included
29
716
027
A5E
SITRANS LR560, dimensions in mm (inch)
4/284
Siemens FI 01 · 2015
5º max.
4”
6”
A
53.2 (2.09)
60 (2.36)
© Siemens AG 2014
Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR560 Specials
■ Schematics
■ Selection and ordering data
SITRANS LR560 Specials
Cable gland
(or NPTcable entry)
Cable shield (if used)
G
Connect the wires
to the terminals as
shown: the polarity
is identified on the
terminal block.
Notes:
1. Depending on the approval rating, glands and plugs may be
supplied with your instrument.
2. DC terminal shall be supplied from a source providing electrical
isolation between the input and output, to meet the applicable safety
requirements of IEC 61010-1.
3. All field wiring must have insulation suitable for rated input voltages.
4. Use shielded twisted pair cable (14 ... 22 AWG) for HARTversion.
5. Separate cables and conduit may be required to conform to standard
instrumentation wiring practices or electrical codes.
SITRANS LR560 connections
Article No.
LR560 Electronics Modules
LR560 Electronics Module, HART, 100 m range,
compatible with 7ML54401XX00XAXX,
no enclosure or process connection included.
7ML1830-3AC
LR560 Electronics Module, PROFIBUS PA,
100 m range, compatible with
7ML54401XX00XBXX, no enclosure or
process connection included.
7ML1830-3AH
LR560 Electronics Module, FOUNDATION
Fieldbus,100 m range, compatible with
7ML54401XX00XCXX, no enclosure or
process connection included.
7ML1830-3AJ
LR560 Electronics Module, HART, 40 m range,
compatible with 7ML54400XX00XAXX,
no enclosure or process connection included.
7ML1830-3AK
LR560 Electronics Module, PROFIBUS PA,
40 m range, compatible with
7ML54400XX00XBXX, no enclosure or
process connection included.
7ML1830-3AL
LR560 Electronics Module, FOUNDATION
Fieldbus, 40 m range, compatible with
7ML54400XX00XCXX, no enclosure or
process connection included.
7ML1830-3AM
LR560 Miscellaneous Spare Kits
Kit, Lid Gasket, EPDM, LR560
7ML1830-3AA
Kit, Wrench for 4" and 6" Aimers, LR560
7ML1830-3AB
Kit, O-rings for 3" Aimer, LR560
7ML1830-3AD
Kit, O-rings for 4" Aimer, LR560
7ML1830-3AE
Kit, O-rings for 6" Aimer, LR560
7ML1830-3AF
Kit, Lid Screw and Purge Plug set with
Hex Keys, LR560
7ML1830-3AG
Kit, Lid, No Window, LR560
7ML1830-3AP
Please contact [email protected] for special requests.
Siemens FI 01 · 2015
4/285
4
© Siemens AG 2014
Level Measurement
Continuous level measurement - Guided wave radar transmitters
Guided wave radar transmitters
■ Overview
■ Mode of operation
Introduction
Interface Detection
Guided Wave Radar transmitters use TDR (time domain reflectometry).
The SITRANS LG, is a transmitter capable of measuring both an
upper level and an interface level. The upper liquid must have a
dielectric constant between 1.6 and 10 and the two liquids have
a difference in dielectric constants greater than 10. A typical
application would be oil over water, with the upper layer of oil
being non-conductive with a dielectric constant of approximately 2 and the lower layer of water being very conductive with
a dielectric constant of approximately 80. This interface
measurement can only be accomplished when the dielectric
constant of the upper medium is lower than the dielectric constant of the lower medium.
Time Domain Reflectometry (TDR)
TDR uses pulses of electromagnetic (EM) energy to measure
distances or levels. When a pulse reaches a dielectric discontinuity (created by media surface), part of the energy is reflected.
The greater the dielectric difference, the greater the amplitude
(strength) of the reflection.
4
The SITRANS LG includes a transmitter and waveguide that has
a characteristic impedance in air and is used as a probe. When
part of the probe is immersed in a material other than air, there is
lower impedance due to the increase in the dielectric. When an
EM pulse is sent down the probe and meets the dielectric
discontinuity, a reflection is generated.
24 V DC, 4 ... 20 mA
loop powered
Air: (dk = 1)
Transmit pulse
A reflection develops from the
liquid surface.
Air: dK = 1
A small amount of energy
continues down the probe in a
low dielectric fluid.
Media dK > 1.4
4/286
Siemens FI 01 · 2015
Upper
Level
Signal
Low dielectric
medium
(e.g. oil: dk = 2)
Emulsion layer
Interface
Level
Signal
High dielectric
medium
(e.g. water: dk = 80)
© Siemens AG 2014
Level Measurement
Continuous level measurement - Guided wave radar transmitters
Guided wave radar transmitters
■ Application
4
•Š
•Š
•Š
•ŠP
•ŠP
•ŠP
•ŠP
•ŠP
XGUUUG\GŠz›GO“’ŒGžˆ›Œ™P
\WGUUUGXWWGŠz›GO“’ŒG–•Œ P
\GUUUGYWGŠz›GO“’ŒG”ˆŠ•ŒG–“P
XWWGUUUG\WWGŠz›GO“’ŒGš ™œ—V”–“ˆššŒšP
YWGUUUG\WGŠz›GO“’ŒGŠ––’•ŽG–“P
[GUUUGYWG”h
V[GUUUGYWG”h
Siemens FI 01 · 2015
4/287
© Siemens AG 2014
Level Measurement
Continuous level measurement - Guided wave radar transmitters
Guided wave radar transmitters
Guided Wave Radar (Interface) Application Questionnaire
Customer information
Contact:
Prepared By:
Company:
Date:
Notes on the Application:
Address:
City:
4
Zip/Postal Code:
Country:
Phone: (
)
E-mail:
Fax:
(
)
Tank/Vessel Information
Tank top:
Sketch
attached
(supply sketch where possible)
Mounting location:
Tank bottom:
Tank dimensions:
Height:
m/ft
Diameter:
m/ft
Open
Sloped
Top mount
Nozzle Length:
cm/inch
Flat
Flat
Thread mount
Nozzle Diameter:
cm/inch
Conical
Conical
Flange mount
Process connection type:
Parabolic
Parabolic
Bypass/Sidepipe Mount
Process connection size:
Pipe mount
Distance to sidewall:
Pressure:
cm/inch
Displacer replacement
Normal:
(please supply drawings)
Maximum (relief):
Interface Data
Upper material:
Lower material:
Upper material thickness:
Emulsion layer:
Lower material thickness:
cm/inch
Upper material dielectric:
cm/inch
Lower material dielectric:
Emulsion thickness:
Yes
No (preferred)
cm/inch
Material
Liquid
Material being measured:
Coating buildup:
Yes
°C/°F
°C/°F Max:
Material temperature: Norm:
Turbulence:
No
Maximum Viscosity:
Slurry
Density:
No
Yes
kg/m
3
3
Kinematic Viscosity (cSt) = Dynamic Viscosity (cP) / Density (kg/m )
1 ... 5 cSt (like water)
50 ... 100 cSt (like honey)
5 ... 20 cSt (like machine oil)
100 ... 500 cSt (like syrup/molasses)
20 ... 50 cSt (like cooking oil)
>500 cSt (like tar)
Emulsion
layer
Upper
material
Lower
material
Installation
Power available:
Communications:
Outputs required:
HART/ 4 ... 20 mA
4 ...20 mA
Other
(please specify)
Products recommended:
© Siemens Milltronics Process Instruments Inc.
4/288
Siemens FI 01 · 2015
www.siemens.com/processautomation
Form# 2-938R0
© Siemens AG 2014
Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
■ Overview
■ Configuration
Mounting on nozzle
Metal sheet
Flange
Installation in non-metal vessel
The Siemens SITRANS LG series are guided wave radar transmitters for level, level/interface, and volume measurement of
liquids and solids. The Sitrans LG product line can handle
changes in process conditions, high temperatures and pressures, and steam.
The guided microwave principle requires a metal surface on the
process fitting. Therefore, use in plastic vessels etc. an instrument
version with flange (from DN 50) or place a metal sheet, Ø > 200 mm
(8 inch), beneath the process fitting when screwing it in.
Make sure that the plate has direct contact with the process fitting
Mounting socket
If possible, avoid sockets, mount the sensor
flush with the vessel top. If this is not possible,
use short sockets with small diameter.
Higher sockets or sockets with a bigger
diameter can generally be used. They simply
increase the upper blocking distance. Check if
this is relevant for your measurement.
In such cases, always carry out a false signal
suppression after installation.
■ Benefits
•
•
•
•
•
•
•
•
•
High accuracy to ± 2 mm
Advanced Diagnostics available for high degree of safety
Simple menu driven display offers ease of setup
Large range of options offers reliability in most continuous
measurement applications
Ease of maintenance through module design and field
replaceable and adjustable probe options
Perfect solution for wide range of applications from storage to
interface with options for extreme pressure and temperature
conditions
Universally applicable in liquids, interface, slurries and solids
Highly immune to buildup
Wide range of Hygienic options
■ Application
The SITRANS LG series comes in four different models, depending on the applications, level of performance, and functionality
required:
• SITRANS LG240 offers configuration options for your hygienic
and corrosive application requirements
• SITRANS LG250 Highly flexible solution for liquid level and
interface applications. Extremely versatile offering solutions
for storage, separation of materials or difficult ammonia applications
• SITRANS LG260 Ideal for measuring level in medium range
solids applications including; grains, plastics, and cement
• SITRANS LG270 offers configuration options for extreme
conditions including high temperature and high pressure
applications such as: harsh applications found in chemical,
HPI and energy industries for example, LPG gas tanks, steam
boilers and distillation columns
h)
d)
d
h
DN 40 ... DN 150
< 150
Socket must
be
installed flush
> DN 150 ... DN 200 < 100
When welding the socket, make sure that the socket is flush to the
vessel top.
Before beginning the welding work, remove the electronics module
from the sensor. By doing this, you avoid damage to the electronics
through inductive coupling.
Inflowing medium
Do not mount the instruments in
or above the filling stream. Make
sure that you detect the product
surface, not the inflowing product.
SITRANS LG Series installation
Siemens FI 01 · 2015
4/289
4
© Siemens AG 2014
Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
■ Technical specifications
Mode of operation
Design
Measuring principle
Guided wave radar measurement
Measuring range
300 ... 75 000 mm
(11.81 ... 2 952.75 inch)
mA analog output with
HART digital signal
Output range
• Analog
• Start-up current
4 ... 20 mA/HART (SIL optional)
Failure signal current output (adjustable): last valid measured value,
 21 mA,  3.6 mA
Digital communication
HART Version 7 x and multidrop compatible
Modbus
Modbus RTU, Modbus ASCII,
Levelmaster
• Plastic housing plastic PBT
(Polyester)
• Aluminum die-casting housing,
aluminum die-casting AISi10 mg,
powder-coated- basis: polyester
• Stainless steel housing, precision
casting 316L
• Stainless steel housing, electropolished 316L
• Degree of protection
• Type 4/NEMA 4, IP65
• Plastic housing IP66/IP67
• Aluminum and stainless steel
housings are IP66/68
• Cable inlet
2x M20x1.5 or 2 x ½" NPT
Process connections
• Pipe thread, cylindrical (ISO 228 T1) G¾" A, G1" A, G1½" A according to
DIN 3852-A
PROFIBUS PA
Process reference conditions according to DIN EN 61298-1
Performance
• Enclosure
Current: minimum 3.8 mA,
maximum 20.5 mA
 10 mA for 5 ms after switching on,
 3.6 mA
Diagnostic alarm
Non-linearity
• Coaxial
• Single rod probes
• American pipe thread, conical
(ASME B1.20.1)
¾" NPT, 1" NPT, 1½" NPT
• Flanged
DIN from DN 25, ANSI from 1"
• Hygienic
Hygienic fittings
Programming
• Interface models
See manual for more details
Resolution and repeatability
Accuracy ± 2 mm (0.08 inch)
Accuracy
• Coaxial/rod/cable probes
± 2 mm (0.08 inch)
• Interface models
± 5 mm (0.197 inch)
(Note: Typical deviation,
Interface measurement)
Local
Four button, menu-driven data entry
Handheld communicator
Hart communicator
PC
SIMATIC PDM, AMS, PACTware
Power
2 wire Hart version
9.6 ... 35 V DC
4 wire versions
9.6 … 48 V DC, 20 … 42 V AC,
50/60 Hz and 90 … 253 V AC,
50/60 Hz
Modbus
8 … 30 V DC
PROFIBUS PA
9 … 32 V DC
See manual for more details
Electromagnetic compatibility
(check if needed)
• Measuring cycle time
< 500 ms
• Step response time
3s
• Temperature Effects
The measurement error from the
process conditions is in the specified
pressure and temperature range of
below 1 %
Rated operating conditions
• Ambient temperature for enclosure -40 ... +80 °C (-40 ... +176 °F)
• LCD readable temperature range
-40 ... +80 °C (-40 ... +176 °F) with
display heated option
• Location
Indoor/outdoor
• Installation category
II
• Pollution degree
2
• Relative Humidity
20 ... 85 %
Medium conditions
Dielectric constant
dK  1.4 (configuration dependent)
Note: for measurement below 1.4 use
probe end tracking.
Process temperature range
-196 ... +450 °C (-321 ... +842 °F)
Vessel pressure
-1 … +400 bar
(-100 … +40 000 kPa)
4/290
Approx. 0.8 ... 8 kg
(0.176 ... 17.64 lb)
Materials
Output
4
Instrument weight (dependent on
process fitting) - see manual for
further details
Siemens FI 01 · 2015
Note: see manual for specific power
based on ordered options
Certificates and approvals
Hazardous approvals:
ATEX, FM, CSA, IECex
Hygienic approvals
EHEDG
Overfill protection
WHG
Ship approval
ABS, CCS, GL
© Siemens AG 2014
Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
SITRANS LG240
SITRANS LG250
Industries
Food, Beverage and
Pharmaceutical
Chemical/HPI/Power/General Cement, power generation,
food, processing,
mineral processing, mining
SITRANS LG260
SITRANS LG270
Chemical/HPI/Power/General
Applications
Hygienic and corrosive
applications
Liquids, storage and process
vessels with agitators,
vaporous liquids, interface
Cement, fly ash, grain, coal,
flour, plastics
Aggressive applications in
Liquids, storage and process
vessels with agitators,
vaporous liquids, high
temperatures and pressures,
low dielectric media
Range
32 m
75 m
60 m
60 m
Performance
± 2 mm
± 2 mm
± 2 mm
± 2 mm
Temperature
-40 ... +150 °C
(-40 ... +302 °F)
-40 ... +200 °C
(-40 ... +392 °F)
-40 ... +200 °C
(-40 ... +392 °F)
-196 ... +450 °C
(-320.8 ... +842 °F)
Communications
• 4 ... 20 mA/HART
• Modbus, Modbus RTU,
Modbus ASCII, Levelmaster
• PROFIBUS PA
• SIMATIC PDM
• DTM/FDT for PACTware
• Fieldcare
• 4 ... 20 mA/HART
• Modbus, Modbus RTU,
Modbus ASCII, Levelmaster
• PROFIBUS PA
• SIMATIC PDM
• DTM/FDT for PACTware
• Fieldcare
• 4 ... 20 mA/HART
• Modbus, Modbus RTU,
Modbus ASCII, Levelmaster
• PROFIBUS PA
• SIMATIC PDM
• DTM/FDT for PACTware
• Fieldcare
• 4 ... 20 mA/HART
• Modbus, Modbus RTU,
Modbus ASCII, Levelmaster
• PROFIBUS PA
• SIMATIC PDM
• DTM/FDT for PACTware
• Fieldcare
Siemens FI 01 · 2015
4/291
4
© Siemens AG 2014
Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
Selection and Ordering data
SITRANS LG240
Guided Wave Radar sensor for Hygienic and
corrosive continuous level and interface
measurement of liquids.
Article No.
77777 - 7777 777
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Approvals
Ordinary location CE9)
ATEX II 1G, 1/2G, 2G Ex ia IIC T69)
ATEX II 1G,1/2G 2G Ex ia IIC + ATEX II 1D,
1/2D, 1/3D, 2D, Ex t IIIC IP66 T11)13)15)24)
4
0A
0E
0H
ATEX II 1/2G, 2G Ex d ia IIC
ATEX II 1/2G, 2G Ex d ia IIC + ATEX II 1/2D,
2D IP6x1)11)12)13)15)24)
ATEX II 1D, 1/2D, 1/3D, 2D, Ex t IIIC
IP66 T11)13)15)24)
0J
IEC Ex ia IIC T69)
IEC Ex ia IIC T6 + IEC IP6x T tD11)13)15)24)
IEC Ex d ia IIC T61)12)
0P
0Q
0R
IEC Ex d ia IIC T6 + IEC IP6x
T tD1)11)12)13)15)24)
FM (NI) Class I, Div. 2, Groups A, B, C, D
FM (IS) Class I, II, III, Div. 1, Groups A, B, C,
D, E, F
0S
FM(XP-IS) Class I, II, III, Div. 1, Groups A, B,
C, D, E, F, G1)12)
CSA (NI) Class I, Div. 2, Groups A, B, C ,D
(DIP) Class II, III, Div. 1, Groups E, F, G11)13)15)
1C
CSA (IS) Class I, II, III, Div. 1, Groups A, B,
C,D, E, F, G
CSA (XP-IS) Class I, II, III, Div. 1, Groups A,
B, C, D, E, F, G1)12)
1F
T61)12)
0K
0N
1A
1B
1E
1G
Probe version/Material
A
Probe rod ø10 mm (0.39 inch)/PFA2)7)
D
B
C
Process fitting/Material
Clamp 2" PN 16 (ø64 mm) DIN 32676,
ISO 2852/1.4435 (BN2)4)
Clamp 2" PN 16 (ø64 mm) DIN 32676,
ISO 2852/PTFE-TFM 1600
Clamp 2½" PN 10 (ø77.5 mm) DIN 32676,
ISO2852/1.4435 (BN2)4)
00
Clamp 2½" PN 10 (ø77.5 mm) DIN 32676,
ISO 2852/PTFE-TFM 1600
Clamp 3" PN 10 (ø91 mm) DIN 32676,
ISO 2852/1.4435 (BN2)4)
Clamp 3" PN 10 (ø91 mm) DIN 32676,
ISO 2852/PTFE-TFM 1600
03
Clamp 4" PN6 (ø119 mm) DIN 32676,
ISO 2852/1.4435(BN2)4)
Clamp 4" PN6 (ø119 mm) DIN 32676,
ISO 2852/PTFE-TFM 1600
Bolting DN 32, PN 40 DIN11851/
1.4435(BN2)4)
06
Bolting DN 32, PN 40 DIN11851/
PTFE-TFM 1600
Bolting DN 40, PN 40 DIN11851/
1.4435 (BN2)4)
10
Bolting DN 40, PN 40 DIN11851/
PTFE-TFM 1600
Bolting DN 50, PN 25 DIN11851/
1.4435(BN2)4)
12
Siemens FI 01 · 2015
Selection and Ordering data
SITRANS LG240
Guided Wave Radar sensor for Hygienic and
corrosive continuous level and interface
measurement of liquids.
Article No.
Order Code
7ML588077777 - 7777 777
Bolting DN 50, PN 25 DIN11851/
PTFE-TFM 1600
Bolting DN 65, PN 25 DIN11851/
PTFE-TFM 1600
Flange DN 25, PN 40 Form C, DIN 2501/
PTFE-TFM 1600
14
Flange DN 40, PN 40 Form C, DIN 2501/
PTFE-TFM 1600
Flange DN 50, PN 40 Form C, DIN 2501/
PTFE-TFM 1600
Flange DN 50, PN 40 Form V13, DIN 2513/
PTFE-TFM 1600
21
Flange DN 65, PN 40 Form C, DIN 2513/
PTFE-TFM 1600
Flange DN 80, PN 40 Form C, DIN 2501/
PTFE-TFM 1600
Flange DN 100, PN 16 Form C, DIN 2501/
PTFE-TFM 1600
24
Flange DN 80, PN 40 EN1092-1 Form B1/
PTFE-TFM 1600
Flange DN 100, PN 40 EN1092-1 Form B1/
PTFE-TFM 1600
Flange 2" 150 lb RF, ANSI B16.5/
PTFE-TFM 1600
27
Flange 2" 300 lb RF, ANSI B16.5/
PTFE-TFM 1600
Flange 3" 150 lb RF, ANSI B16.5/
PTFE-TFM 1600
Flange 4" 150 lb RF, ANSI B16.5/
PTFE-TFM 1600
31
15
20
22
23
25
26
28
30
32
33
Electronics
Probe cable ø4 mm (0.16 inch) with gravity
weight/PFA2)7)
Probe exchangeable rod (ø8 mm) / 1.4435
(BN2), can be autoclaved (Ra < 0.76 µm)3)7)
Probe exchangeable rod (ø8 mm) / 1.4435
(BN2), (Ra < 0.76 µm)3)7)
4/292
Order Code
7ML5880-
01
02
04
05
07
08
11
13
Two-wire 4 ... 20mA/HART
Four-wire Modbus19)20)21)22)
Two-wire 4...20mA/HART with SIL
qualification17)18)
0
1
2
Four-wire 4...20mA/HART; 90...253V AC;
50/60 Hz1)8)10)
Four-wire 4...20mA/HART; 9.6...48V DC;
20...42 V AC1)8)10)
PROFIBUS PA
3
4
5
Seal/Process temperature
Without glass seal/-40 ... +150 °C
(-40 ... +302 °F)5)11)
FFKM (Kalrez 6221)/-20...150 °C
(-4... +302 °F)
EPDM (Freudenberg 70 EPDM 291)/
-20...130 °C (-4 ... +266 °F)
A
B
C
Housing/Protection/Cable
Plastic IP66/IP67 M20x1.5/blind stopper
Plastic IP66/IP67 ½" NPT/blind stopper
Aluminium/IP66/IP68 (0.2 bar) M20x1.5/
blind stopper
A
B
C
Aluminium/IP66/IP68 (0.2 bar) ½" NPT/
blind stopper
Aluminium double chamber/IP66/IP68
(0.2 bar) M20x1.5/blind stopper
Aluminium double chamber/IP66/IP68
(0.2 bar) ½" NPT/blind stopper
D
Stainless steel (precision casting) 316L/
IP66/IP68 (0.2 bar) M20x1.5/blind stopper
Stainless steel (precision casting) 316L/
IP66/IP68 (0.2 bar) ½" NPT/blind stopper
Stainless steel (electropolished) 316L/
IP66/IP68 (0.2 bar) M20x1.5/blind stopper
G
E
F
H
J
© Siemens AG 2014
Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
Selection and Ordering data
SITRANS LG240
Guided Wave Radar sensor for Hygienic and
corrosive continuous level and interface
measurement of liquids.
Stainless steel (electropolished) 316L/IP66/
IP68 (0.2 bar) ½" NPT/blind stopper
Stainless steel double chamber/IP66/IP68
(0.2 bar) M20x1.5/blind stopper
Stainless steel double chamber/IP66/IP68
(0.2 bar) ½" NPT/blind stopper
Aluminium/IP66/IP68 (0.2 bar) M20x1.5/
cable gland stainless steel
Aluminium double chamber/IP66/IP68
(0.2 bar) M20x1.5/cable gland stainless steel
Stainless steel (precision casting) 316L/IP66/
IP68 (0.2 bar) M20x1.5/Cable gland stainless
steel
Stainless steel (electropolished) 316L/IP66/
IP68 (0.2 bar) M20x1.5/cable gland stainless
steel
Aluminium single chamber / IP66/IP68
(0.2 bar) M20x1.5 / Cable gland brass
nickel-plated
Aluminium double chamber / IP66/IP68
(0.2 bar) M20x1.5 / Cable gland brass
nickel-plated
Stainless steel single chamber (precision
casting) / IP66/IP68 (0.2 bar) M20x1.5 /
Cable gland brass nickel-plated
Article No.
Order Code
7ML5880-
SITRANS LG240
Guided Wave Radar sensor for Hygienic and
corrosive continuous level and interface
measurement of liquids.
7ML5880-
K
Further designs (mandatory)
Order Code
L
Please add "-Z" to Article No. and specify
Order code(s).
77777 - 7777 777
M
N
P
Q
R
W
X
Y
Lengths
Rod ø8 mm (0.31 inch)/1.4435
(Basle standard 300 ... 4 000 mm)
300 ... 1 000 mm (11.81 ... 39.37 inch)14)
1 001 ... 2 000 mm (39.41 ... 78.74 inch)14)
2 001 ... 3 000 mm (78.78 ... 118.11 inch)14)
3 001 ... 4 000 mm
(118.15 ... 157.48 inch)14)
Article No.
Selection and Ordering data
0
1
2
3
Order Code
77777 - 7777 777
Supplementary electronics
Without
Additional current output 4 ... 20 mA1)23)
A00
A01
Local display interface
Without
Mounted
Laterally mounted1)
E00
E01
E02
Language of display
German
English
French
Dutch
Italian
L00
L01
L02
L03
L04
Spanish
Portuguese
Russian
Chinese
Japanese
L05
L06
L07
L08
L09
Operating instructions
German
English
French
Spanish
M00
M01
M02
M03
4
Order code
Selection and Ordering data
Further designs (optional)
Please add "-Z" to Article No. and specify Order
code(s).
Rod ø10 mm (0.24 inch)/PFA
(300 ... 4 000 mm)
300 mm (11.81 inch)14)
500 mm (19.69 inch)14)
300 ... 1 000 mm (11.81 ... 39.37 inch)14)
9 R1A
9 R1B
9 R1C
1 001 ... 5 000 mm (39.41 ... 78.74 inch)14)
2 001 ... 3 000 mm (78.78 ... 118.11 inch)14)
3 001 ... 4 000 mm
(118.15 ... 157.48 inch)14)
9 R1D
9 R1E
9 R1F
Cable ø4 mm (0.16 inch)/PFA
(500 ... 32 000 mm)
500 mm (9.69 inch)
501 ... 1 000 mm (19.72 ... 39.37 inch)
1 001 ... 2 000 mm (39.37 ... 196.85 inch)
9 R1G
9 R1H
9 R1 J
2 001 ... 4 000 mm (196.89 ... 393.70 inch)
4 001 ... 5 000 mm (393.74 ... 590.55 inch)
5 001 ... 10 000 mm (590.59 ... 787.40 inch)
9 R1K
9 R1L
9 R1M
10 001 ... 15 000 mm (787.44 ... 984.25 inch)
15 001 ... 20 000 mm
(984.29 ... 1 181.10 inch)
9 R1N
9 R1P
20 001 ... 25 000 mm
(1 181.14 ... 1 377.95 inch)
25 001 ... 32 000 mm
(1 377.99 ... 1 574.80 inch)
9 R1Q
9 R1R
Enter the total insertion length in plain text description
Y01
Enter the total length of rigid part (cable version
only)
Y02
Cleaning included certificate: oil, grease and silicone free
W01
Identification Label (measurement loop) stainless
steel
Y17
Identification Label (measurement loop) Foil
Y18
3.1 Certificate instrument16)
C12
3.1 Certificate material (NACE0175)16)
D07
3.1 Certificate instrument with test data16)
C25
2.2 Certificate material16)
C15
Quality/test plan16)
Dye penetration test + 3.1
C26
certificate/instrument16)
C13
X-ray test + 3.1 certificate/instrument16)
C14
Positive material identification test + 3.1 certificate/
instrument16)
C16
Roughness test + 3.1 certificate/instrument16)
C18
Pressure test + 3.1 certificate/instrument16)
C31
Helium leak test + 3.1 certificate/instrument16)
C32
Ferrite measuring accuracy to DIN32514-1 + 3.1
certificate/instrument16)
C60
Pressure test according to Norsok + 3.1 certificate/
instrument16)
C61
5 point calibration certificate + 3.1 certificate/
instrument16)
C62
Siemens FI 01 · 2015
4/293
© Siemens AG 2014
Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
Selection and Ordering data
Article No.
Additional Operating Instructions
German
4 … 20 mA/HART - two-wire, PFA insulated
PBD-51041000
4 … 20 mA/HART - two-wire, Polished version
PBD-51041001
4 … 20 mA/HART - four-wire PFA insulated
PBD-51041002
4 … 20 mA/HART - four-wire Polished version
PBD-51041003
Modbus- PFA insulated
PBD-51041004
Modbus protocol, Polished version
PBD-51041005
PROFIBUS PA, PFA insulated
PBD-51041006
PROFIBUS PA, polished version
PBD-51041007
English
4
4 … 20 mA/HART - two-wire PFA insulated
PBD-51041037
4 … 20 mA/HART - two-wire Polished version
PBD-51041038
4 … 20 mA/HART - four-wire PFA insulated
PBD-51041039
4 … 20 mA/HART - four-wire Polished version
PBD-51041040
Modbus- PFA insulated
Modbus protocol, Polished version
PROFIBUS PA, PFA insulated
PBD-51041043
PROFIBUS PA, polished version
PBD-51041044
Selection and Ordering data
Accessories
Article No.
Sitrans LG, GWR sensor Display Module
A5E34143449
SITRANS RD100, loop powered display see Chapter 7
7ML5741-...
SITRANS RD200, universal input display with
Modbus conversion - see Chapter 7
7ML5740-...
SITRANS RD300, dual line display with totalizer
and linearization curve and Modbus conversion see Chapter 7
7ML5744-...
SITRANS RD500 web, universal remote monitoring
solution for instrumentation - see Chapter 7
7ML5750-...
For applicable back up point level switch see point level measurement section
1)
Available with Housing/Protection/Cable options E,F, L, M only
2)
Available only with PFA Process Fitting/Material including options 01, 03,
05, 07, 10, 12, 14 ... 33 (PTFE-TFM 1600 options)
3)
PBD-51041041
Available only with Process Fitting/Material options 00, 02, 04, 06, 08, 11,
and 13 [1.4435 (BN2) options]
4)
Available with Length options 0, 1, 2, 3 only (Rod ø8 mm 1.4435 options)
PBD-51041042
5)
Available with Length options R1A ... R1R only (Rod ø10 mm/PFA and
Cable ø4 mm/PFA options)
7)
Available only with the same rod or cable diameter in Length options
8)
Available with Supplementary electronic option A00 and Indicating/Adjustment modules E00, E01
9)
Available with Supplementary electronic option A01 approval options
0A,0E, and 0P
French
4 … 20 mA/HART - two-wire PFA insulated
PBD-51041111
4 … 20 mA/HART - two-wire Polished version
PBD-51041112
10)
Available with Approval options 0A,0J,0K,0N,0R,OS,1A,1C,1E,1F, and 1G
4 … 20 mA/HART - four-wire PFA insulated
PBD-51041113
11)
Available with Version/Material options A and D only
4 … 20 mA/HART - four-wire Polished version
PBD-51041114
12)
Available with Indicating/adjustment modules E00 and E01
Modbus- PFA insulated
PBD-51041115
13)
Available with Seal/Process temperature C only
14)
Modbus protocol, Polished version
PBD-51041116
Not available with Y02
15)
Available with Housing/Protection options C, D, E, F, G, H, L, M
PROFIBUS PA, PFA insulated
PBD-51041117
16)
PROFIBUS PA, polished version
PBD-51041118
Listed Certificates are not available with all configurations, please contact
factory for more information
17)
SIL electronic option 2 available with Approval options 0A, 0E, 0H, 0N, 0P,
0Q, 1A, 1B, 1E and 1F
Spanish
4 … 20 mA/HART - two-wire PFA insulated
PBD-51041074
18)
Available with Supplementary electronic option A00, SIL electronics
4 … 20 mA/HART - two-wire Polished version
PBD-51041075
19)
Modbus only available with Approval options GP and NI and XP-IS/Ex d ia
4 … 20 mA/HART - four-wire PFA insulated
PBD-51041076
20)
Modbus only available with two chamber housing options
21)
4 … 20 mA/HART - four-wire Polished version
PBD-51041077
Modbus not available with Supplementary electronic (only for HART)
option
Modbus- PFA insulated
PBD-51041078
22)
Modbus not available with lateral mount display option
Modbus protocol, Polished version
PBD-51041079
23)
Not available with indicating/adjustment module E02
24)
PROFIBUS PA, PFA insulated
PBD-51041080
Available with Housing/protection options D, F, H and M
PROFIBUS PA, polished version
PBD-51041081
4/294
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
Selection and Ordering data
SITRANS LG250
A guided wave radar sensor for continuous
level and interface measurement of liquids.
Article No.
77777 - 7777 777
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Approvals
Ordinary location CE16)
Shipping approval19)28)29)
ATEX II 1G, 1/2G, 2G Ex ia IIC T616)
Order Code
7ML5881-
Article No.
Selection and Ordering data
SITRANS LG250
A guided wave radar sensor for continuous
level and interface measurement of liquids.
Order Code
7ML588177777 - 7777 777
Process fitting/Material
0A
0B
0E
ATEX II 1G, 1/2G, 2G Ex ia IIC T6 + shipping
approval GL19)28)29)
ATEX II 1G,1/2G 2G Ex ia IIC + ATEX II 1D,
1/2D, 1/3D, 2D, Ex t IIIC IP6616)23)40)
ATEX II 1/2G, 2G Ex d ia IIC T61)21)
0G
ATEX II 1/2G, 2G Ex d ia IIC + ATEX II 1D,
1/2D, 1/3D, 2D, Ex t IIIC IP66 T1)21)23)40)
ATEX II 1/2G, 2G Ex d IIC T614)20)
ATEX II 1/2G, 2G Ex d IIC + ATEX II 1D, 1/2D,
1/3D, 2D, Ex t IIIC IP66 T 14)20)23)40)
0K
ATEX II 1D, 1/2D, 1/3D, 2D, Ex t IIIC IP66
T20)23)40)
IEC Ex ia IIC 16)
IEC Ex ia IIC T6 + IEC IP6x T tD16)20)23)40)
0N
IEC Ex d ia IIC T61)21)23)40)
IEC Ex d ia IIC T6 + IEC IP6x T tD1)20)21)40)
IEC Ex d IIC T614)20)
0R
0S
0T
IEC Ex d IIC T6 + IEC IP6x T tD14)20)23)40)
FM (NI) Class I, Div. 2, Groups A, B, C, D
FM (IS) Class I, II, III, Div. 1, Groups A, B, C,
D, E, F
0U
1A
1B
FM(XP-IS) Class I, II, III, Div. 1, Groups A, B,
C, D, E, F, G1)21)
FM (XP) Class I, Div. 1, Groups A, B, C, D20)
CSA (NI) Class I, Div. 2, Groups A, B, C ,D
(DIP) Class II, III, Div. 1, Groups E, F, G
1C
CSA (IS) Class I, II, III, Div. 1, Groups A, B,
C,D, E, F, G
CSA (XP-IS) Class I, II, III, Div. 1, Groups A,
B, C, D, E, F, G1)21)
CSA (XP) Class I, II, III, Div. 1, Groups A, B,
C, D, E, F, G14)20)
1F
0H
0J
0L
0M
0P
0Q
1D
1E
1G
1H
Probe version/Material
Probe exchangeable cable ø2 mm
(0.08 inch) with gravity weight/316L8)9)11)26)
Probe exchangeable cable ø2 mm
(0.08 inch) center weight/316L8)9)12)26)
Probe exchangeable cable ø4 mm
(0.16 inch) with gravity weight/316L8)9)11)26)
A
Probe exchangeable cable ø4 mm
(0.16 inch) with center weight/316L8)9)12)26)
Probe exchangeable rod
ø8 mm (0.31 inch)/316L2)8)10)11)26)
Probe exchangeable rod
ø12 mm (0.47 inch)/316L3)8)10)11)24)26)
D
Probe coax version ø21.3 mm (0.84 inch)
with single hole/316L8)9)11)26)27)
Probe coax version ø21.3 mm (0.84 inch)
with multiple hole/316L8)9)11)26)27)
G
Probe coax version ø21.3 mm (0.84 inch)
for Ammonia application/316L4)8)9)11)25)31)
Probe coax version ø42.2 mm (1.66 inch)
with multiple hole/316L 5)8)9)11)24)26)27)
J
B
C
E
F
H
Thread G¾" (DIN 3852-A) PN 6/316L
Thread ¾" NPT (ASME B1.20.1) PN 6/316L
Thread G¾" (DIN 3852-A) PN 40/316L
00
01
02
Thread ¾" NPT (ASME B1.20.1) PN 40/316L
Thread G¾" (DIN 3852-A) PN 100/316L
Thread ¾" NPT (ASME B1.20.1) PN 100/316L
03
04
05
Thread G1" (DIN 3852-A) PN 40/316L
Thread 1" NPT (ASME B1.20.1) PN 40/316L
Thread G1" (DIN 3852-A) PN 100/316L
06
07
08
Thread 1" NPT (ASME B1.20.1) PN 100/316L
Thread G1½" (DIN 3852-A) PN 40/316L
Thread 1½" NPT (ASME B1.20.1) PN 40/316L
10
11
12
Thread G1½" (DIN 3852-A) PN1 00/316L
Thread 1½" NPT (ASME B1.20.1) PN 100/316L
Thread 2 NPT PN 40, ASME B1.20.1/316L37)38)
13
14
15
Flange DN 25 PN 40 Form C, DIN 2501/316L
Flange DN 25 PN 40 Form F, DIN 2501/316L
Flange DN 40 PN 40 Form C, DIN 2501/316L
20
21
22
Flange DN 50 PN 40 Form C, DIN 2501/316L
Flange DN 50 PN 40 form V13, DIN 2513/316L
Flange DN 80 PN 40 Form C, DIN 2501/316L
23
24
25
Flange DN 80 PN 40 Form V13, DIN 2501/316L
Flange DN 100 PN 16 Form C, DIN 2501/316L
Flange DN 100 PN 16 Form C, DIN 2501/316L
26
27
28
Flange DN 100PN 40 Form C, DIN 2501/316L
Flange DN 100 PN 40 Form V13, DIN 2513/316L
Flange DN 150 PN 16 Form C, DIN 2501/316L
30
31
32
Flange DN 50 PN 40 EN1092-1 Form B1/316L
Flange DN 80 PN 40 EN1092-1 Form B1/316L
Flange 1" 150 lb RF, ANSI B16.5/316L
33
34
35
Flange 1½" 150 lb RF, ANSI B16.5/316L
Flange 2" 150 lb RF, ANSI B16.5/316L
Flange 2" 300 lb RF, ANSI B16.5/316L
36
37
38
Flange 3" 150 lb RF, ANSI B16.5/316L
Flange 3" 300 lb RF, ANSI B16.5/316L
Flange 4" 150 lb RF, ANSI B16.5/316L
40
41
42
Flange 4" 300 lb RF, ANSI B16.5/316L
Flange 6" 150 lb RF, ANSI B16.5/316L
Flange 6" 300lb RF, ANSI B16.5/316L
43
44
45
Electronics
Two-wire 4 ... 20mA/HART
Four-wire Modbus33)34)35)36)
Two-wire 4...20mA/HART with SIL
qualification24)32)
Four-wire 4...20mA/HART; 90...253V AC; 50/
60Hz1)15)17)
Four-wire 4...20mA/HART; 9.6...48V DC;
20...42V AC1)15)17)
PROFIBUS PA
4
0
1
2
3
4
5
K
Siemens FI 01 · 2015
4/295
© Siemens AG 2014
Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
Selection and Ordering data
SITRANS LG250
A guided wave radar sensor for continuous
level and interface measurement of liquids.
Article No.
Order Code
7ML588177777 - 7777 777
B
C
Lengths
FKM (SHS FPM 70C3 GLT)/without glass seal/
-40 ... +80 °C (-40 ... +176 °F)6)
FKM (SHS FPM 70C3 GLT)/without glass seal/
-40 ... +150 °C (-40 ... +302 °F)
FFKM (Kalrez 6375)/with glass seal/
-20 ... +200 °C (-4 ... +392 °F)
A
EPDM (A+P 75.5/KW75F)/without glass seal/
-40 ... +80 °C (-40 ... +176 °F)
EPDM (A+P 75.5/KW75F)/with glass seal/
-40 ... +150 °C (-40 ... +302 °F)
FFKM (Kalrez 6375)/with glass seal/
-20 ... +200 °C (-4 ... +392 °F)
D
EPDM (A+P 75.5/KW75F)/without glass seal/
-40 ... +80°C (-40 ... +176 °F)6)
EPDM (A+P 75.5/KW75F)/without glass seal/
-40 ... +150 °C (-40 ... +302 °F)
EPDM (A+P 75.5/KW75F)/with glass seal/
-40 ... +150 °C (-40 ... +302 °F)
G
Silicone FEP coated (A+P FEP-O-SEAL)/without glass seal/ -40 ... +80 °C (-40 ... +176 °F)6)
Silicone FEP coated (A+P FEP-O-SEAL)/without glass seal/-40 ... +150 °C (-40 ... +302 °F)
Silicone FEP coated (A+P FEP-O-SEAL)/with
glass seal/-40 ... +150 °C (-40 ... +302 °F)
With borosilicate glass lead through/with glass
seal/-60 ... +150 °C (-76 ... +302 °F)7)
FFKM (Kalrez 6375)/without glass seal/
-20 … +200 °C
FKM (SHS FPM 70C3 GLT)/with glass seal/
-40 ... 80 °C6)
E
F
Y
300 ... 1 000 mm (11.81 ... 39.37 inch)22)
1 001 ... 2 000 mm (39.41 ... 78.74 inch)22)
2 001 ... 3 000 mm (78.78 ... 118.11 inch)22)
0
1
2
3 001 ... 4 000 mm (118.15 ... 157.48 inch)22)
4 001 ... 5 000 mm (157.52 ... 196.85 inch)22)
5 001 ... 6 000 mm (196.89 ... 236.22 inch)22)
3
4
5
9 R2A
9 R2B
K
2 001 ... 3 000 mm (78.78 ... 118.11 inch)22)
3 001 ... 4 000 mm (118.15 ... 157.48 inch)22)
9 R2C
9 R2D
Cable lengths ø2 or 4 mm/316L
L
M
N
P
Q
D
Stainless steel (precision casting) 316L/
IP66/IP68 (0.2 bar) M20x1.5/blind stopper
Stainless steel (precision casting) 316L/
IP66/IP68 (0.2 bar) ½" NPT/blind stopper
Stainless steel (electropolished) 316L/
IP66/IP68 (0.2 bar) M20x1.5/blind stopper
L
Siemens FI 01 · 2015
X
J
Aluminium/IP66/IP68 (0.2 bar) ½" NPT/blind
stopper
Aluminium double chamber/IP66/IP68
(0.2 bar) M20x1.5/blind stopper
Aluminium double chamber/IP66/IP68
(0.2 bar) ½" NPT/blind stopper
4/296
77777 - 7777 777
300 ... 1 000 mm (11.81 ... 39.37 inch)22)
1 001 ... 2 000 mm (39.41 ... 196.85 inch)22)
A
B
C
Stainless steel (electropolished) 316L/IP66/IP68
(0.2 bar) M20x1.5/cable gland stainless steel
Aluminium single chamber / IP66/IP68
(0.2 bar) M20x1.5 / Cable gland brass
nickel-plated
Order Code
7ML5881-
Rod ø12 mm/316L
H
Plastic IP66/IP67 M20x1.5/blind stopper
Plastic IP66/IP67 ½" NPT/blind stopper
Aluminium/IP66/IP68 (0.2 bar) M20x1.5/
blind stopper
Aluminium/IP66/IP68 (0.2 bar) M20x1.5/
cable gland stainless steel
Aluminium double chamber/IP66/IP68
(0.2 bar) M20x1.5/cable gland stainless steel
Stainless steel (precision casting) 316L/IP66/
IP68 (0.2 bar) M20x1.5/cable gland stainless
steel
Article No.
Rod ø8 mm/316L
Housing/Protection/Cable
Stainless steel (electropolished) 316L/
IP66/IP68 (0.2 bar) ½" NPT/blind stopper
Stainless steel double chamber/IP66/
IP68 (0.2 bar) M20x1.5/blind stopper
Stainless steel double chamber/IP66/
IP68 (0.2 bar) ½" NPT/blind stopper
SITRANS LG250
A guided wave radar sensor for continuous
level and interface measurement of liquids.
Aluminium double chamber / IP66/IP68
(0.2 bar) M20x1.5 / Cable gland brass
nickel-plated
Stainless steel single chamber (precision
casting) / IP66/IP68 (0.2 bar) M20x1.5/
Cable gland brass nickel-plated
Seal/Second line of defense/
Process temperature
4
Selection and Ordering data
E
F
M
N
501 ... 1 000 mm (19.72 ... 39.37 inch)
1 000 ... 5 000 mm (39.37 ... 196.85 inch)
5 001 ... 10 000 mm (196.89 ... 393.70 inch)
10 001 ... 15 000 mm (393.74 ... 590.55 inch)
9 R2E
15 001 ... 20 000 mm (590.59 ... 787.40 inch)
20 001 ... 25 000 mm (787.44 ... 984.25 inch)
25 001 ... 30 000 mm (984.29 ... 1 181.10 inch)
9 R2J
9 R2K
9 R2L
30 001 ... 35 000 mm
(1 181.14 ... 1 377.95 inch)
35 001 ... 40 000 mm
(1 377.99 ... 1 574.80 inch)
40 001 ... 45 000 mm
(1 574.84 ... 1 771.65 inch)
9 R2M
45 001 ... 50 000 mm
(1 771.69 ... 1 968.50 inch)
50 001 ... 55 000 mm
(1 968.54 ... 2 165.35 inch)
55 001 ... 60 000 mm
(2 165.39 ... 2 362.20 inch)
9 R2Q
60 001 ... 65 000 mm
(2 362.24 ... 2 559.06 inch)
65 001 ... 70 000 mm
(2 559.09 ... 2 755.91 inch)
70 001 ... 75 000 mm
(2 759.94 ... 2 952.76 inch)
9 R2T
9 R2F
9 R2G
9 R2H
9 R2N
9 R2P
9 R2R
9 R2S
9 R2U
9 R2V
Coax ø21.3 mm/316L
P
Q
R
S
300 ... 1 000 mm (11.81 ... 39.37 inch)22)
1 001 ... 2 000 mm (39.41 ... 78.74 inch)22)
2 001 ... 3 000 mm (78.78 ... 118.11 inch)22)
9 R3A
9 R3B
9 R3C
3 001 ... 4 000 mm (118.15 ... 157.48 inch)22)
4 001 ... 5 000 mm (157.52 … 196.85 inch)22)
5 001 … 6 000 mm (196.89 … 236.22 inch)22)
9 R3D
9 R3E
9 R3F
Coax ø42.2 mm/316L
T
U
V
W
300 ... 1 000 mm (11.81 ... 39.37 inch)22)
1 001 ... 2 000 mm (39.41 ... 78.74 inch)22)
2 001 ... 3 000 mm (78.78 ... 118.11 inch)22)
9 R3G
9 R3H
9 R3J
3 001 ... 4 000 mm (118.15 ... 157.48 inch)22)
4 001 ... 5 000 mm (157.52 … 196.85 inch)22)
5 001 … 6 000 mm (196.89 … 236.22 inch)22)
9 R3K
9 R3L
9 R3M
© Siemens AG 2014
Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
Selection and Ordering data
Article No.
Order Code
Order code
Selection and Ordering data
SITRANS LG250
A guided wave radar sensor for continuous
level and interface measurement of liquids.
7ML5881-
Further designs (optional)
77777 - 7777 777
Please add "-Z" to Article No. and specify Order
code(s).
Further designs (mandatory)
Order Code
Enter the total insertion length in plain text description
Y01
Enter the total length of rigid part (cable version
only)
Y02
Cleaning included certificate: oil, grease and
silicone free
W01
Identification Label (measurement loop) stainless
steel
Y17
Please add "-Z" to Article No. and specify
Order code(s).
Supplementary electronics
Without
Additional current output 4 ... 20 mA1)39)
A00
A01
Dimensions centering weight
(diameter/height)
Without
ø40/30 mm
ø45/30 mm (for 2 inch tubes)
B00
B01
B02
Identification Label (measurement loop) Foil
Y18
3.1 Certificate instrument30)
C12
3.1 Certificate material (NACE0175)30)
D07
ø75/30 mm (for 3 inch tubes)
ø95/30 mm (for 4 inch tubes)
ø1.57/1.18 inch (for 2 inch schedule 160)
B03
B04
B05
3.1-Certificate instrument with test data30)
C25
2.2-Certificate material30)
C15
ø1.77/1.18 inch (for 2 inch schedule 40/80)
ø2.95/1.18 inch (for 3 inch schedule 10/40)
ø3.74/1.18 inch (for 4 inch schedule 80)
B06
B07
B08
Quality/test plan30)
C26
Dye penetration test + 3.1 certificate/instrument30)
C13
X-ray test + 3.1 certificate/instrument30)
C14
Positive material identification test + 3.1 certificate/
instrument30)
C16
Roughness test + 3.1 certificate/instrument30)
C18
Pressure test + 3.1 certificate/instrument30)
C31
Helium leak test + 3.1 certificate/instrument30)
C32
Rod mounted
Without Rod, applicable for coax or cable
probe types only18)
Mounted
Not mounted
C00
C01
C02
4
Local display interface
Without13)
Mounted
Laterally mounted1)
E00
E01
E02
Ferrite measuring accuracy to DIN32514-1 + 3.1
certificate/instrument30)
C60
Pressure test according to Norsok + 3.1 certificate/
instrument30)
C61
Language of display
German
English
French
Dutch
Italian
L00
L01
L02
L03
L04
5 point calibration certificate + 3.1 certificate/
instrument30)41)
C62
Additional Operating Instructions
Article No.
Spanish
Portuguese
Russian
Chinese
Japanese
L05
L06
L07
L08
L09
Operating instructions
German
English
French
Spanish
M00
M01
M02
M03
German
4 … 20 mA/HART - two-wire
PBD-51041010
4 … 20 mA/HART - two-wire coax probe
PBD-51041011
4 … 20 mA/HART - four-wire
PBD-51041012
4 … 20 mA/HART - four-wire coax probe
PBD-51041013
Modbus
PBD-51041014
Modbus- coax probe
PBD-51041015
PROFIBUS PA
PBD-51041016
PROFIBUS PA - coax probe
PBD-51041017
English
4 … 20 mA/HART - two-wire
PBD-51041047
4 … 20 mA/HART - two-wire Coax probe
PBD-51041048
4 … 20 mA/HART - four-wire
PBD-51041049
4 … 20 mA/HART - four-wire Coax probe
PBD-51041050
Modbus
PBD-51041051
Modbus - coax probe
PBD-51041052
PROFIBUS PA
PBD-51041053
PROFIBUS PA - coax probe
PBD-51041054
Siemens FI 01 · 2015
4/297
© Siemens AG 2014
Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
Selection and Ordering data
Article No.
French
4 … 20 mA/HART - two-wire
PBD-51041121
4 … 20 mA/HART - two-wire Coax probe
PBD-51041122
4 … 20 mA/HART - four-wire
PBD-51041123
4 … 20 mA/HART - four-wire Coax probe
PBD-51041124
Modbus
PBD-51041125
Modbus- coax probe
PBD-51041126
PROFIBUS PA
PBD-51041127
PROFIBUS PA - coax probe
PBD-51041128
Spanish
4
4 … 20 mA/HART - two-wire
PBD-51041084
4 … 20 mA/HART - two-wire Coax probe
PBD-51041085
4 … 20 mA/HART - four-wire
PBD-51041086
4 … 20 mA/HART - four-wire Coax probe
PBD-51041087
Modbus
PBD-51041088
Modbus- Coax probe
PBD-51041089
PROFIBUS PA
PBD-51041090
PROFIBUS PA - coax probe
PBD-51041091
Accessories
Sitrans LG, GWR sensor Display Module
A5E34143449
SITRANS RD100, loop powered display see Chapter 7
7ML5741-...
SITRANS RD200, universal input display with
Modbus conversion - see Chapter 7
7ML5740-...
SITRANS RD300, dual line display with totalizer
and linearization curve and Modbus conversion see Chapter 7
7ML5744-...
SITRANS RD500 web, universal remote monitoring
solution for instrumentation - see Chapter 7
7ML5750-...
For applicable back up point level switch see point level measurement section
4/298
Siemens FI 01 · 2015
1)
Available with Housing/Protection cable options E, F, Q, and R only
Not available with Process fitting/Material options 04, 05, 08, 10, 13, and
14
3)
Available only with Process Fitting/Material options 00 ... 10, 11, 12, 23 ...
34 and 37 ... 45 (Not available with threaded connections less than 1.5
inch and flanges < DN 50/2 inch)
4) Available with Seal option N only
5)
Not available with Process fitting/Material options 00 ... 10, 11, 12, 23 ... 34
and 37 ... 45. (Not available with threaded connections less than 1.5 inch
and flanges < DN 50/2 inch)
6)
Available only with Process fitting/Material options 00 and 01 (options with
max temp of 80 °C (176 °F) only available with PN 6 rated threaded connections)
7) Available with Version/Material option J only
8) Available only with the same diameter probe lengths
9) Available with Rod mounted option C00 only (Coax and cable version
only)
10)
Available with Rod mounted options C01, C02 only (rod versions only)
11)
Available only with Centering weight option B00 (no centering weight
option)
12)
Available with Centering weight options B01 ... B08 only
13)
Available only with Housing/Protection cable options E,F, Q, R, T (double
chamber options only)
14) Available only with Housing/Protection cable options C, D, L, M and
approval option 1D
15)
Available with Supplementary electronic option A00 and Indicating/Adjustment modules E00, E01
16)
Available with Supplementary electronic option A01 and Approval options
0A,0E, and 0P
17) Not Available with Approval options 0B ... 0H 0P, 0Q,1B, and 1F (not available with Intrinsically Safe and shipping approvals)
19)
Not available with Length options 3, 4, 5, R2C and R2D
20
) Available only with Seal options C,E,F,J,M, N and Q [second line of
defense (with glass seal) for all explosion proof options]
21)
Available with Indicating/adjustment modules E00 and E01
22)
Not available with Y02
23)
Available with Housing/Protection options C, D, E,F,L,M,Q,R (dust approvals)
24) SIL electronics option 2 available with Approval options 0A, 0E, 0G, 0H,
0L, 0M, 0N, 0P, 0U, 0Q 0T,1A, 1B, 1D, 1E, 1F and 1H
25)
Available with Process Fitting/Material options 04,05,08,10,13 ... 45
26)
Not available with Process fitting /Material options 04,05,08,10,13, and14
27)
Not available with Process Fitting/Material options 00 and 01
28)
Available with Housing/Protection/Cable options A,B,C,D,E,F,L,M,R,S,T,
and U
29)
Available with Electronic option 0 only
30)
Listed Certificates are not available with all configurations, please contact
factory for more information
31) Not available with Process fitting/Material options 02, 03, 06, 07, 11, and
12 or threaded options below PN 100
32)
Available with supplementary electronic option A00, SIL electronics
33)
Modbus only available with Approval options GP and NI and XP-IS/Ex d ia
34)
Modbus only available with two chamber housing options
35)
Modbus not available with Supplementary electronic (only for HART)
option
36)
Modbus not available with lateral mount display option
37)
Not available with version/material option K
38)
Not available with Seal/Process temperature options A,G K and Q
39)
Not available Indicating/adjustment module E02
40)
Available with Housing/protection options D, F, M,R (dust approvals)
41)
Available with Version/Material A, B, C, D, E and F
2)
© Siemens AG 2014
Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
.E
Selection and Ordering data
Article No. Order Code
Selection and Ordering data
Article No. Order Code
SITRANS LG260
A guided wave radar sensor for level measurement of solids.
7ML5882-
SITRANS LG260
A guided wave radar sensor for level measurement of solids.
7ML5882-
77777 - 7777 777
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Process fitting/Material
Approvals
Ordinary location CE4)12)
Shipping approval9)10)
ATEX II 1G, 1/2G, 2G Ex ia IIC T64)12)
0A
0B
0E
ATEX II 1G, 1/2G, 2G Ex ia IIC T6 + shipping
approval GL9)
ATEX II 1G,1/2G 2G Ex ia IIC + ATEX II 1D,
1/2D, 1/3D, 2D, Ex t IIIC IP66 T8)10)12)21)
ATEX II 1/2G, 2G Ex d ia IIC T61)7)12)
0G
ATEX II 1/2G, 2G Ex d ia IIC + shipping
approval (GL)1)7)9)10)
ATEX II 1/2G, 2G Ex d IIC + ATEX II 1D, 1/2D,
1/3D, 2D, Ex t IIIC IP667)8)12)21)
ATEX II 1D, 1/2D, 1/3D, 2D, Ex t IIIC
IP6611)12)
0L
ATEX II 1/2G, 2G Ex d IIC + shipping
approval (GL)9)10)11)
ATEX II 1/2G,2G Ex d IIC + II 1D, 1/2D, 1/3D,
2D IP668)11)12)21)
ATEX II 1D, 1/2D, 2D IP6x T8)11)12)21)
0Q
T64)12)
0H
0J
0M
0N
0R
0S
IEC Ex ia IIC
IEC Ex ia IIC T6 + IEC IP6x T tD8)11)12)21)
IEC Ex d ia IIC T61)7)12)
0T
0U
1A
IEC Ex d ia IIC T6 + IEC IP6x T tD7)8)12)21)
IEC Ex d IIC T611)12)
IEC Ex d IIC T6 + IEC IP6x T tD8)11)12)21)
1B
1C
1D
FM (NI) Class I,Div. 2, Groups A, B, C, D12)
FM (NI) Class I, Div. 2, Groups A, B, C, D +
shipping approval (GL)9)10)
FM (IS) Class I, II, III, Div. 1, Groups A, B, C,
D, E, F12)
1F
1G
FM (IS) Class I, II, III, Div. 1, Groups A, B, C,
D, E, F, G + shipping approval (GL)9)10)
FM (XP-IS) Class I, II, III, Div. 1, Groups A, B,
C, D, E, F, G1)7)12)
FM (XP-IS) Class I, II, III, Div. 1, Groups A,
B, C, D, E, F, G + shipping approval
(GL)1)7)9)10)
1J
FM (XP) Class I, Div. 1, Groups A, B, C,
D11)12)
CSA (NI) Class I, Div. 2,Groups A, B, C, D;
(DIP) Class II, III, Div. 1, Groups E, F, G8)12)
CSA (IS) Class I, II, III, Div.1, Groups A, B, C,
D, E, F, G12)
1M
CSA (XP-IS) Class I, II, III, Div. 1, Groups A,
B, C, D, E, F, G1)7)12)
CSA (XP) Class I, II, III, Div. 1, Groups A, B,
C, D, E, F, G11)12)
1Q
Probe version/Material
Probe exchangeable cable ø 4 mm
(0.16 inch) with gravity weight/316
Probe exchangeable cable
ø 6 mm (0.24 inch) with gravity weight/3162)
Probe exchangeable rod ø 16
mm (0.63 inch) / 316L2)6)
77777 - 7777 777
Thread G¾" (DIN 3852-A) PN 40/316L
Thread ¾" NPT (ASME B1.20.1) PN 40/316L
Thread G1" (DIN 3852-A) PN 40/316L
00
01
02
Thread 1" NPT (ASME B1.20.1) PN 40/316L
Thread G1½" (DIN 3852-A) PN 40/316L
Thread 1½" NPT (ASME B1.20.1) PN 40/316L
03
04
05
Thread G2" (DIN 3852-A) PN 40/316L
Flange DN 50 PN 40 Form C, DIN 2501/316L
Flange DN 80 PN 40 Form C, DIN 2501/316L
06
10
12
Flange DN 100 PN 16 Form C, DIN 2501/316L
Flange DN 100 PN 40 Form C, DIN 2501/316L
Flange DN 150 PN 16 Form C, DIN 2501/316L
13
14
15
Flange DN 50 PN 40 EN1092-1 Form B1/316L
Flange DN 80 PN 40 EN1092-1 Form B1/316L
Flange DN 100 PN16 EN1092-1 Form B1/316L
16
17
18
Flange 2" 150 lb RF, ANSI B16.5/316L
Flange 2" 300 lb RF, ANSI B16.5/316L
Flange 3" 150 lb RF, ANSI B16.5/316L
30
32
33
Flange 3" 300 lb RF, ANSI B16.5/316L
Flange 4" 150 lb RF, ANSI B16.5/316L
34
35
Flange 4" 300 lb RF, ANSI B16.5/316L
Flange 6" 150 lb RF, ANSI B16.5/316L
36
37
Electronics
Two-wire 4 ... 20mA/HART
Four-wire Modbus16)17)18)19)
Two-wire 4...20mA/HART with SIL
qualification14)15)
0
1
2
Four-wire 4...20mA/HART; 90...253V AC;
50/60Hz1)3)5)
Four-wire 4...20mA/HART; 9.6...48V DC;
20...42 V AC1)3)5)
PROFIBUS PA
1H
4
3
4
5
Seal/Process temperature
1K
1L
1N
1P
FKM (SHS FPM 70C3 GLT)/-40 ... +80 °C
(-40 ... +176 °F)
FKM (SHS FPM 70C3 GLT)/-40 ... +150 °C
(-40 ... +302 °F)
FFKM (Kalrez 6375)/-20 ... +200 °C
(-4 ... +392 °F)
A
EPDM (A+P 75.5/KW75F)/-40 ... +80 °C
(-40 ... +176 °F)
EPDM (A+P 75.5/KW75F)/-40 ... +150 °C
(-40 ... +392 °F)
D
B
C
E
Housing/Protection/Cable
1R
A
B
E
Plastic IP66/IP67 M20x1.5/blind stopper
Plastic IP66/IP67 ½" NPT/blind stopper
Plastic 2-chamber/IP66/IP67/M20x1.5/
blind stopper
A
B
C
Plastic 2-chamber/IP66/IP67 /½" NPT/
blind stopper
Aluminium/IP66/IP68 (0.2 bar) M20x1.5/
blind stopper
Aluminium/IP66/IP68 (0.2 bar) ½" NPT/
blind stopper
D
Aluminium double chamber/IP66/IP68
(0.2 bar) M20x1.5/blind stopper
Aluminium double chamber/IP66/IP68
(0.2 bar) ½" NPT/blind stopper
Stainless Steel (precision casting) 316L/IP66/
IP68 (0.2 bar) M20x1.5/blind stopper
G
Siemens FI 01 · 2015
E
F
H
J
4/299
© Siemens AG 2014
Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
Selection and Ordering data
Article No. Order Code
Selection and Ordering data
Article No. Order Code
SITRANS LG260
A guided wave radar sensor for level measurement of solids.
7ML5882-
SITRANS LG260
A guided wave radar sensor for level measurement of solids.
7ML5882-
Stainless steel (precision casting) 316L/IP66/
IP68 (0.2 bar) ½" NPT/blind stopper
Stainless steel (electropolished) 316L/IP66/
IP68 (0.2 bar) M20x1.5/blind stopper
Stainless steel (electropolished) 316L/IP66/
IP68 (0.2 bar) ½" NPT/blind stopper
Stainless steel double chamber/IP66/IP68
(0.2 bar) M20x1.5/blind stopper
Stainless steel double chamber/IP66/IP68
(0.2 bar) ½" NPT/blind stopper
Aluminium/IP66/IP68 (0.2 bar) M20x1.5/
cable gland stainless steel
4
77777 - 7777 777
K
Cable lengths ø6 mm/316L
500 mm (19.69 inch)
501 ... 1 000 mm (19.72 ... 39.37 inch)
1 001 ... 5 000 mm (39.41 ... 196.85 inch)
9 R4A
9 R4B
9 R4C
5 001 ... 10 000 mm (196.89 ... 393.70 inch)
10 001 ... 15 000 mm (393.74 ... 590.55 inch)
15 001 ... 20 000 mm
(590.59 ... 787.40 inch)
9 R4D
9 R4E
9 R4F
20 001 ... 25 000 mm
(787.44 ... 984.25 inch)
25 001 ... 30 000 mm
(984.29 ... 1 181.10 inch)
30 001 ... 35 000 mm
(1 181.14 ... 1 377.95 inch)
9 R4G
35 001 ... 40 000 mm
(1 377.99 ... 1 574.80 inch)
40 001 ... 45 000 mm
(1 574.84 ... 1 771.65 inch)
45 001 ... 50 000 mm
(1 771.69 ... 1 968.50 inch)
9 R4K
9 R4N
X
50 001 ... 55 000 mm
(1 968.54 ... 2 165.35 inch)
55 001 ... 60 000 mm
(2 165.39 ... 2 362.20 inch)
Y
Further designs (mandatory)
L
M
N
P
Q
Aluminium double chamber/IP66/IP68
(0.2 bar) M20x1.5/cable gland stainless steel
Stainless steel (precision casting) 316L/IP66/
IP68 (0.2 bar) M20x1.5/cable gland stainless
steel
Stainless steel (electropolished) 316L/IP66/
IP68 (0.2 bar) M20x1.5/cable gland stainless
steel
R
Aluminium single chamber / IP66/IP68
(0.2 bar) M20x1.5 / Cable gland brass
nickel-plated
Aluminium double chamber / IP66/IP68
(0.2 bar) M20x1.5 / Cable gland brass
nickel-plated
Stainless steel single chamber (precision
casting) / IP66/IP68 (0.2 bar) M20x1.5 /
Cable gland brass nickel-plated
W
S
T
Rod ø16 mm/316L
500 mm (19.69 inch)
501 ... 1 000 mm (19.72 ... 39.37 inch)
1 001 ... 2 000 mm (39.41 ... 78.74 inch)
0
1
2
2 001 ... 3 000 mm (78.78 ... 118.11 inch)
3 001 ... 4 000 mm (118.15 ... 157.48 inch)
3
4
4 001 ... 5 000 mm (157.52 ... 196.85 inch)
5 001 ... 6 000 mm (196.89 ... 216.53 inch)
5
6
Cable lengths ø2 or 4 mm/316
501 ... 1 000 mm (19.72 ... 39.37 inch)
1 001 ... 5 000 mm (39.41 ... 196.85 inch)
5 001 ... 10 000 mm (196.89 ... 393.70 inch)
9 R2E
9 R2F
9 R2G
10 001 ... 15 000 mm (393.74 ... 590.55 inch)
15 001 ... 20 000 mm (590.59 ... 787.40 inch)
20 001 ... 25 000 mm (787.44 ... 984.25 inch)
9 R2H
9 R2 J
9 R2K
25 001 ... 30 000 mm
(984.29 ... 1 181.10 inch)
30 001 ... 35 000 mm
(1 181.14 ... 1 377.95 inch)
35 001 ... 40 000 mm
(1 377.99 ... 1 574.80 inch)
9 R2L
40 001 ... 45 000 mm
(1 574.84 ... 1 771.65 inch)
45 001 ... 50 000 mm
(1 771.69 ... 1 968.50 inch)
9 R2P
50 001 ... 55 000 mm
(1 968.54 ... 2 165.35 inch)
55 001 ... 60 000 mm
(2 165.39 ... 2 362.20 inch)
9 R2R
Siemens FI 01 · 2015
9 R4H
9 R4J
9 R4L
9 R4M
9 R4P
Order Code
Please add "-Z" to Article No. and specify
Order code(s).
Lengths
4/300
77777 - 7777 777
9 R2M
9 R2N
9 R2Q
9 R2S
Supplementary electronics
Without1)
Additional current output 4 ... 20 mA1)20)
Rod mounted
Without Rod, applicable for coax or cable
probe types only
Mounted
Not mounted
A00
A01
C00
C01
C02
Local display interface
Without
Mounted
Laterally mounted1)
E00
E01
E02
Language of display
German
English
French
Dutch
Italian
L00
L01
L02
L03
L04
Spanish
Portuguese
Russian
Chinese
Japanese
L05
L06
L07
L08
L09
Operating instructions
German
English
French
Spanish
M00
M01
M02
M03
© Siemens AG 2014
Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
Selection and Ordering data
Order code
Further designs (optional)
Please add "-Z" to Article No. and specify Order
code(s).
Selection and Ordering data
Accessories
Article No.
Sitrans LG, GWR sensor Display Module
A5E34143449
7ML5741-...
Enter the total insertion length in plain text description
Y01
SITRANS RD100, loop powered display see Chapter 7
Cleaning included certificate: oil, grease and silicone free
W01
SITRANS RD200, universal input display with
Modbus conversion - see Chapter 7
7ML5740-...
Identification Label (measurement loop) stainless
steel
Y17
7ML5744-...
Identification Label (measurement loop) Foil
Y18
SITRANS RD300, dual line display with totalizer
and linearization curve and Modbus conversion see Chapter 7
3.1 Certificate instrument13)
C12
SITRANS RD500 web, universal remote monitoring
solution for instrumentation - see Chapter 7
7ML5750-...
3.1 Certificate material
(NACE0175)13)
D07
3.1-Certificate instrument with test data13)
C25
For applicable back up point level switch see point level measurement section
2.2-Certificate material13)
C15
1)
Available only with Housing/Protection/Cable Options G, H, N, P
C26
2)
Not available with Process/Fitting/Material options 00, 01, 02, and 03
Dye penetration test + 3.1 certificate/instrument13)
C13
3)
X-ray test + 3.1 certificate/instrument13)
C14
Positive material identification test + 3.1 certificate/
instrument 13)
C16
Roughness test + 3.1 certificate/instrument13)
C18
Pressure test + 3.1 certificate/instrument13)
C31
Helium leak test + 3.1 certificate/instrument13)
C32
Ferrite measuring accuracy to DIN32514-1 + 3.1
certificate/instrument13)
C60
Pressure test according to Norsok + 3.1 certificate/
instrument13)
C61
5 point calibration certificate + 3.1 certificate/
instrument13)
C62
Operating Instructions
Article No.
Quality/test
plan13)
German
4 … 20 mA/HART - two-wire
PBD-51041020
4 … 20 mA/HART - four-wire
PBD-51041021
Modbus
PBD-51041022
PROFIBUS PA
PBD-51041023
Available with Supplementary electronic option A00 and Indicating/adjustment modules E00, E01
4)
Available with Supplementary electronic option A01
5)
Not Available with Approval options 0B ... 0H 0L, 0Q, 1B, 1F, 1G,1J, 1L
(not available with Intrinsically Safe and shipping approvals)
6)
Available with Rod Mounted options C01 and C02
7)
Available with Indicating/adjustment modules E00 and E01
8)
Available with Housing Protection options E, F, G, H, J, K, N, P
9)
Not available with Housing/Protection/Cable options L, M, and T
10)
Available with Electronic option 0 only
11)
Available with Seal/Process temperature option C only
12)
Available with Version/Material option E only
13)
Listed Certificates are not available with all configurations, please contact
factory for more information
14)
SIL electronics option 2 available with Approval options 0A, 0E, 0G, 0H,
0N, 0Q, 0R, 0S, 0T, 0U, 1C, 1D, 1F, 1H, 1M, 1N, 1P, and 1R
15)
Available with supplementary electronic option A00, SIL electronics
16)
Modbus available only with Approval options GP and NI and XP-IS/
Ex d ia
17)
Modbus available only with two chamber housing options
18)
Modbus not available with supplementary electronic (only for HART)
option
19)
Modbus not available with lateral mount display option
20)
Not available with Indicating/adjustment module E02
21)
Available with Housing Protection F, H, P and K
English
4 … 20 mA/HART - two-wire
PBD-51041057
4 … 20 mA/HART - four-wire
PBD-51041058
Modbus
PBD-51041059
PROFIBUS PA
PBD-51041060
French
4 … 20 mA/HART - two-wire
PBD-51041131
4 … 20 mA/HART - four-wire
PBD-51041132
Modbus
PBD-51041133
PROFIBUS PA
PBD-51041134
Spanish
4 … 20 mA/HART - two-wire
PBD-51041094
4 … 20 mA/HART - four-wire
PBD-51041095
Modbus
PBD-51041096
PROFIBUS PA
PBD-51041097
Siemens FI 01 · 2015
4/301
4
© Siemens AG 2014
Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
Selection and Ordering data
Article No. Order Code
Selection and Ordering data
Article No. Order Code
SITRANS LG270
A guided wave radar sensor for continuous
level and interface measurement of liquids in
aggressive applications
7ML5883-
SITRANS LG270
A guided wave radar sensor for continuous
level and interface measurement of liquids in
aggressive applications
7ML5883-
77777 - 7777 777
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Approvals
Ordinary location CE3)
Shipping approval17)18)19)
ATEX II 1G, 1/2G, 2G Ex ia IIC T63)
4
Process fitting/Material
0A
0B
0E
ATEX II 1G, 1/2G, 2G Ex ia IIC T6 + shipping
approval GL17)18)19)
ATEX II 1G,1/2G 2G Ex ia IIC + ATEX II 1D,
1/2D, 2D IP6x16)28)
ATEX II 1/2G, 2G Ex d ia IIC T61)10)14)
0G
ATEX II 1/2G, 2G Ex d ia IIC + ship
(GL)1)10)14)17)18)19)
ATEX II 1/2G, 2G Ex d ia IIC + ATEX II 1/2D,
2D IP6x10)14)16)28)
ATEX II 1/2G, 2G Ex d IIC T611)
0L
ATEX II 1/2G, 2G Ex d IIC + ship approval
(GL)3)17)18)19)
ATEX II 1/2G, 2G Ex d IIC + ATEX II 1/2D, 2D
IP6x11)16)28)
ATEX II 1D, 1/2D, 2D IP6x T16)28)
0Q
IEC Ex ia IIC T6
IEC Ex ia IIC T6 + IEC IP6x T tD16)28)
IEC Ex d ia IIC T61)10)14)
0T
0U
1A
0H
0J
0M
0N
0R
0S
tD10)14)16)28)
IEC Ex d ia IIC T6 + IEC IP6x T
IEC Ex d IIC T611)
IEC Ex d IIC T6 + IEC IP6x T tD11)16)28)
1B
1C
1D
FM (NI) Class I, Div.2, Groups A, B, C, D
FM (NI) Class I, Div.2, Groups A, B, C, D +
ship approval (GL)17)18)19)
FM (IS) Class I, II, III, Div. 1, Groups A, B, C,
D, E, F
1F
1G
FM (IS) Class I, II, III, Div. 1, Groups A, B, C,
D, E, F, G + ship approval (GL)17)18)19)
FM (XP-IS) Class I, II, III, Div. 1, Groups A, B,
C, D, E, F, G1)10)14)
FM (XP-IS) Class I, II, III, Div. 1, Groups A, B,
C, D, E, F, G + shipping approval
(GL)1)10)17)18)19)
1J
FM (XP) Class I, Div.1, Groups A, B, C, D
CSA (NI) Class I, Div. 2, Groups A, B, C, D;
(DIP) Class II, III, Div.1, Groups E, F, G16)
CSA (IS) Class I, II, III, Div.1, Groups A, B, C,
D, E, F, G
1M
1N
CSA (XP-IS) Class I, II, III, Div. 1, Groups A,
B, C, D, E, F, G1)10)14)
CSA (XP) Class I, II, III, Div. 1, Groups A, B,
C, D, E, F, G11)
1Q
1H
1K
1L
1P
1R
Version/Material
Probe exchangeable cable ø 2 mm
(0.08 inch) with gravity weight/316L4)7)
Probe exchangeable cable ø2 mm
(0.08 inch) center weight/316L 5)7)
Probe exchangeable cable ø4 mm
(0.16 inch) with gravity weight/316L4)7)
A
Probe exchangeable cable ø4 mm
(0.16 inch) with center weight/316L5)7)
Probe exchangeable rod ø 16 mm
(0.63 inch) /316L4)7)9)
D
Probe coax version ø 42.2 mm (1.66 inch)
with multiple hole/316L4)7)
F
Probe coax version ø 42.2 mm (1.66 inch);
multiple hole; reference distances/
316L4)7)13)
G
4/302
Siemens FI 01 · 2015
77777 - 7777 777
B
C
E
Thread G1½" (DIN 3852-A) PN400/316L
Thread 1½" NPT (ASME B1.20.1) PN400/316L
Thread 1½" NPT (ASME B1.20.1) PN400/C22
00
01
02
Flange DN 50 PN 40 Form C, DIN 2501/316L
Flange DN 50 PN 40 form V13, DIN 2513/316L
Flange DN 65 PN 64 Form V13, DIN 2501/316L
10
11
12
Flange DN 80 PN 40 Form C, DIN 2501/316L
Flange DN 80 PN 40 Form V13, DIN 2501/316L
Flange DN 80 PN 100 Form L, DIN 2501/316L
13
14
15
Flange DN 100 PN 16 Form C, DIN 2501/316L
Flange DN 100 PN 16 Form C, DIN 2501/316L
Flange DN 100 PN 40 Form C, DIN 2501/316L
16
17
18
Flange DN 100 PN 40 Form V13, DIN 2513/
316L
Flange DN 150 PN 16 Form C, DIN 2501/316L
Flange DN 50 PN 40 EN1092-1 Form B1/316L
20
Flange DN 100 PN 160 GOST 12815-80.7/
316L
Flange DN 80 PN 160 Form C, DIN 2501/316L
Flange DN 80 PN 250 Form L, DIN 2501/316L
23
Flange DN 50 PN 160, EN1092-1 Form B1/
316L
Flange DN 50 PN 160, EN1092-1 Form B2/
316L
Flange DN 50 PN 320, EN1092-1 Form B1/
316L
62
Flange DN 65 PN 250, EN1092-1 Form B1/
316L
Flange DN 100 PN 160, EN1092-1 Form B2/
316L
Flange 2" 150 lb RF, ANSI B16.5/316L
65
Flange 2" 300 lb RF, ANSI B16.5/316L
Flange 2" 600 lb RF, ANSI B16.5/316L
Flange 2" 1 500 lb RF, ANSI B16.5/316L
31
32
33
Flange 3" 150 lb RF, ANSI B16.5/316L
Flange 3" 300 lb RF, ANSI B16.5/316L
Flange 3" 600 lb RF, ANSI B16.5/316L
34
35
36
Flange 3" 900 lb RF, ANSI B16.5/316L
Flange 3" 2 500 lb RF, ANSI B16.5/316L
Flange 3 ½" 600 lb RF, ANSI B16.5/316L
37
38
40
Flange 4" 150 lb RF, ANSI B16.5/316L
Flange 4" 300 lb RF, ANSI B16.5/316L
Flange 4" 600 lb RF, ANSI B16.5/316L
41
42
43
Flange 6" 150 lb RF, ANSI B16.5/316L
Flange 6" 300 lb RF, ANSI B16.5/316L
Flange 6" 600 lb RF, ANSI B16.5/316L
44
45
46
Flange 2"150 lb Fisher special return/316L
Flange 2" 900 lb RF, ANSI B16.5/316L
Flange 3" 1 500 lb RF, ANSI B16.5/316L
47
50
51
Flange 4" 900 lb RF, ANSI B16.5/316L
Flange 4" 1 500 lb RF, ANSI B16.5/316L
Flange 4" 2 500 lb RJF, ANSI B16.5/316L
52
53
54
21
22
60
61
63
64
66
30
© Siemens AG 2014
Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
Selection and Ordering data
Article No. Order Code
Selection and Ordering data
Article No. Order Code
SITRANS LG270
A guided wave radar sensor for continuous
level and interface measurement of liquids in
aggressive applications
7ML5883-
SITRANS LG270
A guided wave radar sensor for continuous
level and interface measurement of liquids in
aggressive applications
7ML5883-
Electronics
Two-wire 4 ... 20mA/HART
Four-wire Modbus23)24)25)26)
Two-wire 4...20mA/HART with SIL
qualification21)22)
Four-wire 4...20mA/HART; 90...253V AC; 50/
60Hz1)2)6)
Four-wire 4...20mA/HART; 9.6...48V DC;
20...42 V AC1)2)6)
PROFIBUS PA
Seal/Second line of defense/
Process temperature
Ceramic-graphite/with glass seal/
-196 ... +280 °C (-321 ... +536 °F)
Ceramic-graphite /with glass seal/
-196 ... +450 °C (-321 ... +842 °F)
77777 - 7777 777
Lengths
0
1
2
Rod ø16 mm/316L
3
4
5
A
B
Plastic IP66/IP67 M20x1.5/blind stopper
Plastic IP66/IP67 ½" NPT/blind stopper
Aluminium/IP66/IP68 (0.2 bar) M20x1.5/
blind stopper
A
B
C
Aluminium/IP66/IP68 (0.2 bar) ½" NPT/
blind stopper
Aluminium double chamber/IP66/IP68
(0.2 bar) M20x1.5/blind stopper
Aluminium double chamber/IP66/IP68
(0.2 bar) ½" NPT/blind stopper
D
Stainless steel (precision casting) 316L/
IP66/IP68 (0.2 bar) M20x1.5/blind stopper
Stainless steel (precision casting) 316L/
IP66/IP68 (0.2 bar) ½" NPT/blind stopper
Stainless steel (electropolished) 316L
IP66/IP68 (0.2 bar) M20x1.5/blind stopper
L
Aluminium/IP66/IP68 (0.2 bar) M20x1.5/
cable gland stainless steel
Aluminium double chamber/IP66/IP68
(0.2 bar) M20x1.5/cable gland stainless steel
Stainless steel (precision casting) 316L/
IP66/IP68 (0.2 bar) M20x1.5/Cable gland
stainless steel
Stainless steel (electropolished) 316L/
IP66/IP68 (0.2 bar) M20x1.5/cable gland
stainless steel
Aluminium single chamber / IP66/IP68
(0.2 bar) M20x1.5 / Cable gland brass
nickel-plated
Aluminium double chamber / IP66/IP68
(0.2 bar) M20x1.5 / Cable gland brass
nickel-plated
Stainless steel single chamber (precision
casting) / IP66/IP68 (0.2 bar) M20x1.5 /
Cable gland brass nickel-plated
300 mm (11.81 inch)15)
500 mm (19.69 inch)15)
501 ... 1 000 mm (19.72 ... 39.37 inch)15)
0
1
2
1 001 ... 2 000 mm (39.41 ... 78.74 inch)15)
2 001 ... 3 000 mm (78.78 ... 118.11 inch)15)
3 001 ... 4 000 mm
(118.15 ... 157.48 inch)15)
3
4
5
4 001 ... 5 000 mm
(157.52 ... 196.85 inch)15)
5 001 ... 6 000 mm
(196.89 ... 216.53 inch)15)
6
7
Cable lengths ø2 or 4 mm/316L
Housing/Protection/Cable
Stainless steel (electropolished) 316L/
IP66/IP68 (0.2 bar) ½" NPT/blind stopper
Stainless steel double chamber/IP66/IP68
(0.2 bar) M20x1.5/blind stopper
Stainless steel double chamber/IP66/IP68
(0.2 bar) ½" NPT/blind stopper
77777 - 7777 777
E
F
M
N
P
Q
501 ... 1 000 mm (19.72 ... 39.37 inch)
1 000 ... 5 000 mm (39.37 ... 196.85 inch)
5 001 ... 10 000 mm (196.89 ... 393.70 inch)
9 R2E
9 R2F
9 R2G
10 001 ... 15 000 mm (393.74 ... 590.55 inch)
15 001 ... 20 000 mm (590.59 ... 787.40 inch)
20 001 ... 25 000 mm (787.44 ... 984.25 inch)
9 R2H
9 R2J
9 R2K
25 001 ... 30 000 mm
(984.29 ... 1 181.10 inch)
30 001 ... 35 000 mm
(1 181.14 ... 1 377.95 inch)
35 001 ... 40 000 mm
(1 377.99 ... 1 574.80 inch)
9 R2L
40 001 ... 45 000 mm
(1 574.84 ... 1 771.65 inch)
45 001 ... 50 000 mm
(1 771.69 ... 1 968.50 inch)
9 R2P
50 001 ... 55 000 mm
(1 968.54 ... 2 165.35 inch)
55 001 ... 60 000 mm
(2 165.39 ... 2 362.20 inch)
9 R2R
9 R2M
9 R2N
9 R2Q
9 R2S
Coax ø42.2 mm/316L
R
S
T
U
V
300 ... 1 000 mm (11.81 ... 39.37 inch)15)
1 001 ... 2 000 mm (39.41 ... 78.74 inch)15)
2 001 ... 3 000 mm (78.78 ... 118.11 inch)15)
9 R3G
9 R3H
9 R3J
3 001 ... 4 000 mm
(118.15 ... 157.48 inch)15)
4 001 ... 5 000 mm
(157.52 … 196.85 inch)15)
5 001 … 6 000 mm
(196.89 … 236.22 inch)15)
9 R3K
9 R3L
9 R3M
W
X
Y
Siemens FI 01 · 2015
4/303
4
© Siemens AG 2014
Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
Selection and Ordering data
Article No. Order Code
Selection and Ordering data
SITRANS LG270
A guided wave radar sensor for continuous
level and interface measurement of liquids in
aggressive applications
7ML5883-
Further designs (optional)
77777 - 7777 777
Please add "-Z" to Article No. and specify Order
code(s).
Further designs (mandatory)
Order Code
Please add "-Z" to Article No. and specify
Order code(s).
4
Supplementary electronics
Without
Additional current output 4 ... 20 mA1)27)
A00
A01
Dimensions centering weight
(diameter/height)
Without
ø40/30 mm
ø45/30 mm (for 2 inch tubes)
B00
B01
B02
ø75/30 mm (for 3 inch tubes)
ø95/30 mm (for 4 inch tubes)
ø1.57/1.18 inch (for 2 inch schedule 160)
B03
B04
B05
ø1.77/ 1.18 inch (for 2 inch schedule 40/80)
ø2.95/1.18 inch (for 3 inch schedule 10/40)
ø3.74/ 1.18 inch (for 4 inch schedule 80)
B06
B07
B08
Rod mounted
Without Rod, applicable for coax or cable
probe types only8)
Mounted
Not mounted
Y02
Cleaning included certificate: oil, grease and
silicone free
W01
Identification Label (measurement loop) stainless
steel
Y17
Identification Label (measurement loop) Foil
Y18
3.1 Certificate instrument20)
C12
3.1 Certificate material (NACE0175)20)
D07
3.1-Certificate instrument with test data20)
C25
2.2-Certificate material20)
C15
Quality/test
plan20)
C26
C14
Positive material identification test + 3.1 certificate/
instrument20)
C16
C00
Roughness test + 3.1 certificate/instrument20)
C18
C01
C02
Pressure test + 3.1 certificate/instrument20)
C31
Helium leak test + 3.1 certificate/instrument20)
C32
Ferrite measuring accuracy to DIN32514-1 + 3.1
certificate/instrument20)
C60
Pressure test according to Norsok + 3.1 certificate/
instrument20)
C61
5 point calibration certificate + 3.1 certificate/
instrument20)29)
C62
Additional Operating Instructions
Article No.
Language of display
German
English
French
Dutch
Italian
L00
L01
L02
L03
L04
L05
L06
L07
L08
L09
Siemens FI 01 · 2015
Enter the total length of rigid part (cable version
only, to a maximum of 100 mm)
C13
E00
E01
E02
4/304
Y01
X-ray test + 3.1 certificate/instrument20)
Without
Mounted
Laterally mounted1)
Operating instructions
German
English
French
Spanish
Enter the total insertion length in plain text description
Dye penetration test + 3.1 certificate/instrument20)
Local display interface
Spanish
Portuguese
Russian
Chinese
Japanese
Order code
M00
M01
M02
M03
German
4 … 20 mA/HART - two-wire
PBD-51041025
4 … 20 mA/HART - two-wire coax probe
PBD-51041026
4 … 20 mA/HART - four-wire
PBD-51041027
4 … 20 mA/HART - four-wire coax probe
PBD-51041028
Modbus
PBD-51041029
Modbus- Coax probe
PBD-51041030
PROFIBUS PA
PBD-51041031
PROFIBUS PA, Coax probe
PBD-51041032
English
4 … 20 mA/HART - two-wire
PBD-51041062
4 … 20 mA/HART - two-wire coax probe
PBD-51041063
4 … 20 mA/HART - four-wire
PBD-51041064
4 … 20 mA/HART - four-wire coax probe
PBD-51041065
Modbus
PBD-51041066
Modbus- coax probe
PBD-51041067
PROFIBUS PA
PBD-51041068
PROFIBUS PA, Coax probe
PBD-51041069
© Siemens AG 2014
Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
Selection and Ordering data
Article No.
French
4 … 20 mA/HART - two-wire
PBD-51041136
4 … 20 mA/HART - two-wire coax probe
PBD-51041137
4 … 20 mA/HART - four-wire
PBD-51041138
4 … 20 mA/HART - four-wire coax probe
PBD-51041139
Modbus
PBD-51041140
Modbus- Coax probe
PBD-51041141
PROFIBUS PA
PBD-51041142
PROFIBUS PA, Coax probe
PBD-51041143
Spanish
4 … 20 mA/HART - two-wire
PBD-51041099
4 … 20 mA/HART - two-wire coax probe
PBD-51041100
4 … 20 mA/HART - four-wire
PBD-51041101
4 … 20 mA/HART - four-wire coax probe
PBD-51041102
Modbus
PBD-51041103
Modbus- Coax probe
PBD-51041104
PROFIBUS PA
PBD-51041105
PROFIBUS PA, Coax probe
PBD-51041105
4
Accessories
Sitrans LG, GWR sensor Display Module
A5E34143449
SITRANS RD100, loop powered display see Chapter 7
7ML5741-...
SITRANS RD200, universal input display with
Modbus conversion - see Chapter 7
7ML5740-...
SITRANS RD300, dual line display with totalizer
and linearization curve and Modbus conversion see Chapter 7
7ML5744-...
SITRANS RD500 web, universal remote monitoring
solution for instrumentation - see Chapter 7
7ML5750-...
For applicable back up point level switch see point level measurement section
1)
Available with Housing/Protection/Cable options E, F, Q, R, and T
Available with Supplementary electronic option A00 and Indicating/adjustment modules E00, E01
3)
Available with Supplementary electronics A01
4) Available with Centering weight option B00 only
5)
Available with Centering weight options B01 ... B08 only
6)
Available with Approval options 0A,0B,0J,0K,0N,0R,OS,1A,1C,1E,1F, and
1G
7)
Available only with the same diameter probe lengths
8)
Available with Version/Material options A, B, C, D, F, G
9) Available with Rod Mounted options C01 and C02
10)
Available with Indicating/adjustment modules E00 and E01
11)
Available with Housing/Protection Cable options C, D, L, M only
12) Version/Material Hastelloy C22, temperature is limited to 400 °C (752 °F)
13)
Not available with Length R3G
14) Available with Housing/Protection Cable options E, F, Q, and R
15) Y02 only available with Cable options
16)
Available with Housing protection options C, D, E,F,L, M,Q, and R
17) Not available with Housing/Protection/Cable options N, P, and V
18) Available with Electronic option 0 only
19)
Not available with Version/Material options E, F, and G
20) Listed Certificates are not available with all configurations, please contact
factory for more information
21)
SIL electronics option 2 available with Approval options 0A, 0E, 0G, 0H,
0N, 0Q, 0R, 0S, 0T, 0U, 1C, 1D, 1F, 1H, 1M, 1N, 1P and 1R
22) Available with Supplementary electronic option A00, SIL electronics
23)
Available with Approval options 0A, 0H, 0K, 0R, 0S, 0U, 1A, 1C, 1D, 1E, 1F,
1H, 1N, 1P and 1R
24) Modbus only available with two chamber housing options
25)
Modbus not available with Supplementary electronic (only for HART)
option
26) Modbus not available with lateral mount display option
27)
Not available with Indicating/adjustment module E02
28) Available with Housing protection options D, F, M and R
29) Available with Version/Material A, B, C, D and E
2)
Siemens FI 01 · 2015
4/305
© Siemens AG 2014
Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
■ Characteristic curves
SITRANS LG240, Ambient temperature/process temperature, standard version
Ambient
Temperature
Maximum
Permissible
Temperature
80 °C
(176 °F)
4
0 °C
(32 °F)
-20 °C
(-68 °F)
-40 °C
(-104 °F)
SITRANS LG240, Ambient temperature/process temperature curve
4/306
Siemens FI 01 · 2015
150 °C
(302 °F)
Process
Temperature
© Siemens AG 2014
Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
SITRANS LG250, Ambient temperature/process temperature, standard version
Ambient
Temperature
Maximum
Permissible
Temperature
80 °C
(176 °F)
Limited
Temperature
Range
65 °C
(149 °F)
0 °C
(32 °F)
-40 °C
(-104 °F)
80 °C
(176 °F)
130 °C
(266 °F)
150 °C
(302 °F)
4
Process
Temperature
-40 °C
(-104 °F)
SITRANS LG250, Ambient temperature/process temperature, temperature adapter version
Ambient
Temperature
Maximum
Permissible
Temperature
80 °C
(176 °F)
Limited
Temperature
Range
55 °C
(131 °F)
0 °C
(32 °F)
-20 °C
(-68 °F)
150 °C
(302 °F)
200 °C
(392 °F)
Process
Temperature
-40 °C
(-104 °F)
SITRANS LG250, Ambient temperature/process temperature curves
Siemens FI 01 · 2015
4/307
© Siemens AG 2014
Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
SITRANS LG260, Maximum tensile load with cereals and plastic granules - cable: ø 4 mm (0.157 inch)
1
1
12
6
3
3
10
5
4
8
4
4
5
5
6
3
6
4
2
2
6
1
2
4
0
"A"
0
5
10
15
20
25
30
2
0
"B"
35
0
5
10
15
20
25
30
35
A. Cereals
B. Plastic granules
1. Tensile force in kN (the determined value must be multiplied with safety factor 2)
2. Cable length in m
3. Vessel diameter 12 m (39.37 ft)
4. Vessel diameter 9 m (29.53 ft)
5. Vessel diameter 6 m (19.69 ft)
6. Vessel diameter 3 m (9.843 ft)
SITRANS LG260, Maximum tensile load with sand and cement - cable: ø 4 mm (0.157 inch)
1
1
20
20
18
18
3
16
14
3
16
14
4
12
4
12
5
10
10
5
8
8
6
6
6
6
4
4
2
2
2
"C"
0
0
5
10
15
20
25
30
35
2
"D"
0
0
5
10
C. Sand
D. Cement
1. Tensile force in kN (the determined value must be multiplied with safety factor 2)
2. Cable length in m
3. Vessel diameter 12 m (39.37 ft)
4. Vessel diameter 9 m (29.53 ft)
5. Vessel diameter 6 m (19.69 ft)
6. Vessel diameter 3 m (9.843 ft)
SITRANS LG260, Maximum tensile load curves
4/308
Siemens FI 01 · 2015
15
20
25
30
35
© Siemens AG 2014
Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
SITRANS LG260, Ambient temperature/process temperature, standard version
Cable version with ø 4 mm (0.157 inch)
Cable version, PA coated with ø 6 mm (0.236 inch)
Ambient
Temperature
Maximum
Permissible
Temperature
80 °C
(176 °F)
Limited
Temperature
Range
65 °C
(149 °F)
0 °C
(32 °F)
-40 °C
(-104 °F)
130 °C
(266 °F)
150 °C
(302 °F)
4
Process
Temperature
-40 °C
(-104 °F)
SITRANS LG260, Ambient temperature/process temperature, temperature adapter version
Cable version with ø 4 mm (0.157 inch)
Cable version, PA coated with ø 6 mm (0.236 inch)
Ambient
Temperature
Maximum
Permissible
Temperature
80 °C
(176 °F)
Limited
Temperature
Range
55 °C
(131 °F)
0 °C
(32 °F)
-20 °C
(-68 °F)
150 °C
(302 °F)
200 °C
(392 °F)
Process
Temperature
-40 °C
(-104 °F)
SITRANS LG260, Ambient temperature/process temperature curves
Siemens FI 01 · 2015
4/309
© Siemens AG 2014
Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
SITRANS LG260, Ambient temperature/process temperature, standard version
Cable version with ø 6 mm (0.236 inch)
Cable version, PA coated with ø 11 mm (0.433 inch)
Ambient
Temperature
Maximum
Permissible
Temperature
80 °C
(176 °F)
4
0 °C
(32 °F)
150 °C
(302 °F)
-40 °C
(-104 °F)
Process
Temperature
-40 °C
(-104 °F)
SITRANS LG260, Ambient temperature/process temperature, temperature adapter version
Cable version with ø 6 mm (0.236 inch)
Cable version, PA coated with ø 11 mm (0.433 inch)
Ambient
Temperature
Maximum
Permissible
Temperature
80 °C
(176 °F)
Limited
Temperature
Range
65 °C
(149 °F)
0 °C
(32 °F)
-20 °C
(-68 °F)
-40 °C
(-104 °F)
SITRANS LG260, Ambient temperature/process temperature curves
4/310
Siemens FI 01 · 2015
170 °C
(338 °F)
200 °C
(392 °F)
Process
Temperature
© Siemens AG 2014
Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
SITRANS LG270, Ambient temperature /process temperature ( -196 … +280 °C/-321 … +536 °F version)
Ambient
Temperature
Maximum
Permissible
Temperature
80 °C
(176°F)
65 °C
(149 °F)
55 °C
(131 °F)
-196 °C
(-321 °F)
-80 °C
(-112 °F)
Limited
Temperature
Range
0 °C
(32 °F)
190 °C
(374 °F)
250 °C 280 °C
(482 °F) (536 °F)
Process
Temperature
4
-40 °C
(-104 °F)
SITRANS LG270, Ambient temperature/process temperature ( -196 … +450 °C/-321 … +842 °F version)
Ambient
Temperature
Maximum
Permissible
Temperature
80 °C
(176 °F)
Limited
Temperature
Range
35 °C
(95 °F)
-196 °C
(-321 °F)
-110 °C
(-230 °F)
0 °C
(32 °F)
-20 °C
(-68 °F)
220 °C
(428 °F)
450 °C
(842 °F)
Process
Temperature
-40 °C
(-104 °F)
SITRANS LG270, Ambient temperature/process temperature curves
Siemens FI 01 · 2015
4/311
© Siemens AG 2014
Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
SITRANS LG270, Process pressure/process temperature ( -196 … +450 °C/-321 … +842 °F version)
Process
Pressure
400 bar
(5800 psig)
380 bar
(5510 psig)
350 bar
(5070 psig)
320 bar
(4640 psig)
300 bar
(4350 psig)
200 bar
(2900 psig)
4
100 bar
(1450 psig)
-200 °C
(-328 °F)
-100 °C
(-148 °F)
SITRANS LG270, Process pressure/process temperature curve
4/312
Siemens FI 01 · 2015
0 °C
(32 °F)
100 °C
(212 °F)
200 °C
(392 °F)
300 °C
(572 °F)
400 °C 450 °C
(752 °F) (842 °F)
Process
Temperature
© Siemens AG 2014
Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
■ Dimensional drawings
LG Series plastic housing
69
(2.72)
86
(3.39)
Ø 77
(3.03)
Ø 77
(3.03)
M16x1.5
114
(4.49)
114
(4.49)
M20x1.5/
½" NPT
M20x1.5/
½" NPT
Single chamber
version
4
Double chamber
version
LG Series aluminum housing
116
(4.57)
Ø 84
(3.31)
91
(3.58)
Ø 84
(3.31)
M16x1.5
124
(4.88)
120
(4.72)
M20x1.5/
½" NPT
M20x1.5
Single chamber
version
M20x1.5/
½" NPT
Double chamber
version
LG Series stainless steel housing
59
(2.32)
69
(2.72)
Ø 80
(3.15)
90
(3.54)
Ø 77
(3.03)
Ø 84
(3.31)
M16x1.5
123
(4.84)
119
(4.69)
112
(4.41)
M20x1.5/
½" NPT
M20x1.5/
½" NPT
Single chamber
version,
electropolished
Single chamber
version,
precision casting
M20x1.5/
½" NPT
Double chamber
version,
precision casting
Note: For integrated display and adjustment module the housing is 9 (0.35) higher for all housing options
SITRANS LG series, dimensions in mm (inch)
Siemens FI 01 · 2015
4/313
© Siemens AG 2014
Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
SITRANS LG240
71.4
(2.81)
69.4
(2.73)
71.4
(2.81)
70
(2.76)
Cable version
with clamp
Cable version
with bolting
115
(4.53)
Ø4
(0.16)
Cable version
with bolting
Cable version
with clamp
300 ... 4 000
(11.81... 157.48)
500 ... 32 000
(19.68 ... 12 598.42)
4
Rod version Ø 10 (0.394), PFA coated
70
(2.76)
69.4
(2.73)
Cable version Ø 4 (0.157), PFA coated
Ø4
(0.16)
Ø 10
(0.39)
Autoclaved version
Cover with
groove nut
65.3
(2.57)
Ø 54
(2.13)
56
(2.02)
183
(7.20)
112
(4.84)
Rod version Ø 8 (0.315), polished
Groove nut
Process fitting
DIN DN 25 DN 32 DN 40/ 1" 1½"
Ø 50.5
DIN DN 50/ 2"
Ø 64
DIN DN 65/ 3"
Ø 91
SITRANS LG240, dimensions in mm (inch)
4/314
Siemens FI 01 · 2015
300 ... 4 000
(11.81... 157.48)
Øw
300 ... 4 000
(11.81... 157.48)
Øw
Ø8
(0.32)
© Siemens AG 2014
Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
SITRANS LG250
Ø 16
(0.63)
Ø2
(0.079)
22
(0.87)
Ø8
(0.32)
51
(2.01)
30
(1.18)
G1½,
1½" NPT
300 ... 6 000
(11.81 ... 236.22)
22
(0.87)
SW 55
(2.17)
300 ... 6 000
(11.81 ... 236.22)
46
(1.81)
Ø 20
(0.79)
Ø4
(0.16)
500 ... 75 000
(19.68 ... 2 952.75)
Ø2
(0.08)
30
(1.18)
Ø 20
(0.79)
Ø 20
(0.79)
100
(3.94)
100
(3.94)
50
(1.97)
Ø 16
(0.63)
G3/4, 3/4" NPT
G1, 1" NPT
G1½, 1½" NPT
30
(1.18)
Ø4
(0.16)
Ø2
(0.08)
Ø 16
(0.63)
SW 36 (1.42")
(G3/4, 3/4" NPT)
SW 41 (1.61")
Cable version with centering
(G1, 1" NPT)
weight
SW 46 (1.81")
(G1½, 1½" NPT)
SW 36 (1.42")
(G3/4, 3/4" NPT)
SW 41 (1.61")
(G1, 1" NPT)
G3/4, 3/4" NPT
SW 46 (1.81")
G1, 1" NPT
(G1½, 1½" NPT)
G1½, 1½" NPT
22
(0.87)
22
(0.87)
500 ... 75 000
(19.68 ... 2 952.75)
Ø4
(0.16)
500 ... 75 000
(19.68 ... 2 952.75)
G3/4, 3/4" NPT
G1, 1" NPT
G1½, 1½" NPT
96
(3.78)
46
(1.81)
SW 36 (1.42")
(G3/4, 3/4" NPT)
SW 41 (1.61")
(G1, 1" NPT)
SW 46 (1.81")
(G1½, 1½" NPT)
46
(1.81)
Rod version
Cable version with gravity weight
Ø 12
(0.47)
Ø4
(0.157)
SITRANS LG250, dimensions in mm (inch)
SITRANS LG250, coax version
Up to 6 m (19.69 ft)
46
(1.81)
ø 21.3
(0.84)
22
(0.86)
G¾, ¾" NPT,
G1, 1" NPT,
G1½, 1½" NPT
SW 55
(2.17)
G1½,
1½" NPT
Up to 6 m (19.69 ft)
SW 36 (1.42)
(G¾, ¾" NPT)
SW 41 (1.61)
(G1, 1" NPT)
SW 46 (1.81)
(G1½, 1½" NPT)
51
(2.01)
Coaxial version
ø 42.2 (1.661)
Coaxial version
ø 21.3 (0.839)
ø 42.2
(1.66)
SITRANS LG250, dimensions in mm (inch)
Siemens FI 01 · 2015
4/315
4
© Siemens AG 2014
Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
SITRANS LG260
Cable version Ø 6 (0.236)/ Ø 11 (0.433)- PA coated
Rod version Ø 16 (0.63)
Cable version Ø 4 (0.157)/ Ø 6 (0.236)- PA coated
Ø 22
(0.79)
Ø4
(0.157)
SITRANS LG260, dimensions in mm (inch)
4/316
Siemens FI 01 · 2015
SW 55
2.17
30
(0.24)
Ø6
(0.24)
Joint rod
Ø 11
(0.43)
150
(5.91)
Ø6
(0.24)
G1½
Ø 11
(0.433)
30
(0.24)
500 ... 65 000
(19.68 ... 2 559.05)
46
(1.81)
500 ... 65 000
(19.68 ... 2 559.05)
Ø4
(0.16)
150
(5.91)
4
22
(0.87)
G 3/4
Joint
cable
Joint
cable
300 ... 6 000
(11.81 ... 236.22)
G1½
SW 36
1.42
80
(3.15)
80
(3.15)
SW 55
2.17
Ø 16
(0.63)
© Siemens AG 2014
Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
SITRANS LG270
Cable version with gravity weight
Ø 20
(0.79)
Ø 20
(0.79)
Ø 16
(0.63)
35
(1.38)
500 ... 60 000
(19.68 ... 2 362.20)
30
(1.18)
Ø2
(0.08)/
Ø4
(0.16)
Ø2
(0.08)/
Ø4
(0.16)
30
(1.18)
30
(1.18)
Ø2/ Ø4
(0.08) (0.16)
100
(3.94)
50
(1.97)
Ø 16
(0.63)
500 ... 60 000
(19.68 ... 2 362.20)
Ø4
(0.16)
Ø2
(0.08)
45
(1.77)
500 ... 60 000
(19.68 ... 2 362.20)
35
(1.38)
G1½
1½" NPT
500 ... 60 000
(19.68 ... 2 362.20)
Ø 16
(0.63)
100
(3.94)
Ø4
(0.16)
312
(12.28)
Max. height of
the vessel
insulation
G1½
1½" NPT
SW 60
(2.36)
237
(9.33)
312
(12.28)
SW 60
(2.36)
237
(9.33)
Max. height of
the vessel
insulation
Cable version with centering weight
Ø 20
(0.79)
Max. height of
the vessel
insulation
SW 60
(2.36)
312
(12.28)
237
(9.33)
Rod version
500 ... 6 000
(19.68 ... 236.22)
300 ... 6 000
(11.81 ... 236.22)
45
(1.77)
35
(1.38)
G1½
1½" NPT
Ø 16
(0.63)
Ø 16
(0.63)
SITRANS LG270, dimensions in mm (inch)
Siemens FI 01 · 2015
4/317
4
© Siemens AG 2014
Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
SITRANS LG270, coax version
ZXYG
OXYUY_P
Temperature version
-196 … +450 °C (-321 … 842 °F)
z~G]W
OYUZ]P
Z\
OXUZ_P
YZ^G
O`UZZP
Temperature version
-196 … +280 °C (-321 … 536 °F)
Up to 6 m (19.69 ft)
Up to 6 m (19.69 ft)
4
\^
OYUY[P
nXÃIV
XÃIGuw{
þG[YUYGOXU]]P
SITRANS LG270, dimensions in mm (inch)
4/318
Siemens FI 01 · 2015
þG[YUYGOXU]]P
© Siemens AG 2014
Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
■ Schematics
2-wire HART electronic option, electronics and connection
compartment, single chamber housing
2-wire HART electronic option, electronics compartment,
double chamber housing
For external display
and adjustment unit
4-20mA
Voltage
supply, signal
output
(+) 1
2 (-)
5
6
7
8
Ground terminal for
connection of the
cable screen
2-wire HART electronic option, connection compartment,
Ex-d-ia double chamber housing
4-20mA
Voltage
supply, signal
output
(+) 1
Internal
connection
to the plug
connector
for external
display
and adjustment
unit (optional)
For display and
adjustment
module or
interface
adapter
For display and adjustment
module or interface adapter
4-20mA
Internal connection
to the connection
compartment
(+) 1
2 (-)
5
6
7
8
4
Note: All 2-wire HART connections and electronics are also
available with SIL
Ground terminal for
connection of the
cable screen
2 (-)
SITRANS LG series, connections
4-wire electronic option, connection compartment with
double chamber housing with mains voltage
For display and
adjustment
module or
interface adapter
( +)1
2(-)
5
6
Internal connection to the
connection compartment
7
8
(+) 1
RVs
2 (-)
5
6
7
IS GND
Common
Power Supply
4 ... 20mA
Active +
4 ... 20mA
Passive +
4-wire HART electronic option, electronics compartment,
double chamber housing
8
Function ground
with installation
according
to CSA
Mass - output
+ 4…20 mA output (passive)
+ 4…20 mA output (active)
TVu
PE
Voltage
Supply
SITRANS LG series, connections
Siemens FI 01 · 2015
4/319
© Siemens AG 2014
Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
Connection compartment with low voltage
Supplementary electronics
(+) 1
1
(+) 7
2 (-)
(+) 1
8 (-)
+
+
RVs
2
2 (-)
5
IS GND
Power Supply
4 ... 20mA
1 First current output (I) - Voltage supply and signal output (HART)
6
7
Function ground
with installation
according to CSA
8
/N
+
+
Mass - output
4 … 20 mA output (passive)
4 … 20 mA output (active)
Voltage
supply
2 Second current output (II) - Voltage supply and signal output
(without HART)
SITRANS LG series, connections
Modbus electronic option,
electronics compartment, double chamber housing
Modbus electronic option, connection compartment
D0 (+)
power supply
(+)1
MODBUS
2(-) off on
Modbus
signal
D1 (-)
USB
3 4
IS GND
USB
interface
Slide switch
for integrated
termination
resistor
(120 Ω)
For display and
adjustment
module or
interface
adapter
4 ... 20 mA
5
5
2 (-)
(+) 1
Voltage
supply
1
6
7 8
1
1 Internal connection to the connection compartment
SITRANS LG series, connection
Profibus electronic option, electronics compartment,
double chamber housing
Profibus electronic option, connection compartment,
double chamber housing
2
2
3
1 R
2(-)
(+)1
3
6 78 9
6 78 9
5
2(-)
01
23 4
(+)1
Bus
23 4
01
Bus
5
4
Active +
4 ... 20mA
Passive +
II
Common
4...20mA
I
1
5
7
6
8
1
T
1 Voltage supply, signal output
2 For display and adjustment module or interface adapter
1 Internal connection to the connection compartment
2 Contact pins for the display and adjustment module or interface adapter
3 Ground terminal for connection of the cable screen
3 Selection switch for bus address
LG series, connection
4/320
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
Profibus electronic option, electronics and connection compartment,
single chamber housing
2
3
6 789
1
6 789
5
2(-)
5
(+)1
0
01
23 4
1
Bus
23 4
01
0
4
5
6 7
8
5
1
1 Voltage supply, signal output
2 For display and adjustment module or interface adapter
4
3 Selection switch for bus address
4 For external display and adjustment unit
5 Ground terminal for connection of the cable screen
LG series, connection
Siemens FI 01 · 2015
4/321
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC300
■ Overview
■ Configuration
Installation
Build up of material in active shield
area does not affect switch
operation.
Mounting on a bypass
4
SITRANS LC300 is an inverse frequency shift capacitance
continuous level transmitter for liquids and solids applications.
It is ideal for standard industrial applications in chemical, hydrocarbon processing, food and beverage, water, wastewater,
and mining, aggregate, and cement industries.
M
■ Benefits
4/322
Siemens FI 01 · 2015
)
(2
Materials with low or high dielectric properties are accurately
measured and patented Active-Shield technology helps in ignoring the effects of buildup or condensation near vessel nozzle.
• Key Applications: Conductive and non-conductive media
including: liquids and solids in standard industrial processes,
bulk solids applications involving dust, and chemical
processes involving vapor
0
SITRANS LC300 is a 2-wire level measurement instrument combining a sophisticated, yet easy-to-adjust microprocessor with
field-proven probes. It is available in four versions: rod, rod with
stilling well, cable with PFA insulation, and cable without
PFA insulation.
.5
■ Application
in
• Patented Active-Shield technology so measurement is
unaffected by material buildup in active shield section
• Highly accurate and reliable PFA-lined probes
• Integrated local LCD display
• 2-wire (4 to 20 mA) current loop design
• Current signaling according to NAMUR NE 43
• Push-button calibration and programming
• Stilling well (ground tube) version for low dielectric media and
non-metallic vessels
Min. 50 (2)
Install probe at least 50 (2) from tank wall.
Note angle of repose and adjust accordingly.
SITRANS LC300 installation, dimensions in mm (inch)
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC300
■ Technical specifications
Input
Safety
Measuring range
1.66 ... 3 300 pF
Span
Min. 3.3 pF
Output
Continuous signal 4 ... 20 mA/
20 ... 4 mA according to NAMUR 43
Accuracy (transmitter)
Temperature stability
0.25 % of actual capacitance value
Non-linearity and repeatability
< 0.4 % of full scale and actual measurement value
Accuracy
Deviation < 0.5 % of actual measurement value
1)
Ambient conditions
• Ambient temperature
• Installation category
• Pollution degree
• Ingress protection
-40 ... +85 °C (-40 ... +185 °F)2)
I
4
Type 4/NEMA 4/IP65 (optional IP68)
Installation conditions
• Location
Indoor/outdoor
Process pressure
Process temperature
Min. dielectric constant r
1.5
General
Probe diameter
• Rod version
• Cable version
Active shield length
• Rod version
• Cable version
Process connection of probe
• Threaded rod mounting
• Europe
Flame Proof
(Intrinsically Safe probe circuit)
• Europe
Explosion Proof
(Intrinsically Safe probe circuit)
• Canada/USA
FM/CSA:
Class II, Div. 1, Groups E,F,G
Class III T4
ATEX 1/2 D T100 °C
ATEX II 1/2 G EEx d [ia] IIC T6 ... T1
ATEX II 1/2 D T100 °C
Class I, Div. 1, Groups A,B,C,D
Class II, Div. 1, Groups E,F,G
Class III T4
Marine
Bureau Veritas Type Approval ABS
Type Approval
-1 ... +35 bar g (-14.6 ... +511 psi g)
Overfill Protection
AIB-Vincotte
-40 ... +200 ºC (-40 ... +392 ºF)3)
Other
Pattern Approval (China)
Aluminum, epoxy-coated
19 mm (0.75 inch) with PFA jacket
9 mm (0.35 inch) with PFA jacket,
6 mm (0.24 inch) without PFA jacket
Threaded: 120 mm (4.72 inch)
Flanged: 100 mm (3.94 inch)
Threaded: 125 mm (4.92 inch)
Flanged: 105 mm (4.13 inch)
1)
When operation is in areas classified as hazardous, observe restrictions
according to relevant certificate.
See also Pressure/Temperature curves on page 4/331.
2)
Thermal isolator is used if process connection temperature exceeds 85 °C
(185 °F)
3)
Not suitable for steam environments
Design: Probe
Rod version
Stilling well
version
Cable version
Length
Min. 300 mm
(12 inch),
max. 5 000 mm
(197 inch)
Min. 300 mm
(12 inch),
max. 5 000 mm
(197 inch)
Min. 1 000 mm
(40 inch),
max. 25 000 mm
(984 inch)
Sensor wetted
parts
PFA, 316L
stainless steel
PFA, 316L
stainless steel
316L stainless
steel or 316L
stainless steel
with PFA insulation
O-ring seal mate- FKM or FFKM
rial
FKM or FFKM
FKM or FFKM
¾",1",1¼", 1½" NPT [(Taper),
ANSI/ASME B1.20.1]
R ¾",1", 1½" [(BSPT),
EN 10226/PT (JIS-T), JIS B 0203]
• Flange mounting
G ¾",1", 1½" [(BSPP),
EN ISO 228-1/PF (JIS-P), JIS B 0202]
1½" NPT [(Taper),
ANSI/ASME B1.20.1]
R 1½" [(BSPT),
EN 10226/PT (JIS-T), JIS B 0203]
G 1½" [(BSPP),
EN ISO 228-1/PF (JIS-P), JIS B 0202]
1 ... 4" ASME, DN 25 ... 100
Enclosure cable inlet
2 x ½" NPT or 2 x M20x1.5
Power supply
12 ... 30 V DC any polarity,
2-wire current loop circuit
• Threaded cable mounting
CE, CSAUS/C, FM, RCM
Dust Ignition Proof
(Intrinsically Safe probe circuit)
• Canada/USA
Design
Material
• Enclosure
According to NAMUR NE 43,
signal 3.8 ... 20.5 mA, fault  3.6 or
 21 mA (22 mA)
Certificates and approvals
Loop current
Rated operating conditions
Measurement current signaling
Thermal isolator
Optional
Optional
Optional
Options
N/A
N/A
Mounting eye for
PFA insulated
cable version
User Interface
Display
Local LCD, 4 digit, each 0 ... 9 and
limited alpha characters
Siemens FI 01 · 2015
4/323
4
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC300
Selection and Ordering data
Article No.
Selection and Ordering data
Article No.
SITRANS LC300, rod version
An inverse frequency shift capacitance continuous
level transmitter for liquids and solids applications.
7ML5670-
SITRANS LC300, rod version
An inverse frequency shift capacitance continuous
level transmitter for liquids and solids applications.
7ML5670-
77 7 77 - 777 0
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Process connection
Threaded, 316L stainless steel
¾" NPT [(Taper), ANSI/ASME B1.20.1]
1" NPT [(Taper), ANSI/ASME B1.20.1]
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
1½" NPT [(Taper), ANSI/ASME B1.20.1]
4
Wetted seals
FKM
FFKM [for process temperatures above -20 °C
(-4 °F)]
0A
0B
0C
0D
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
R 1½" [(BSPT), EN 10226/PT (JIS-T),
JIS B 0203]
1A
1B
1D
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
Welded flange, 316L stainless steel, raised face1)
1" ASME, 150 lb
1" ASME, 300 lb
1" ASME, 600 lb
3A
1½" ASME, 150 lb
1½" ASME, 300 lb
1½" ASME, 600 lb
5D
5E
5F
2" ASME, 150 lb
2" ASME, 300 lb
2" ASME, 600 lb
5G
5H
5J
3" ASME, 150 lb
3" ASME, 300 lb
3" ASME, 600 lb
5K
5L
5M
4" ASME, 150 lb
4" ASME, 300 lb
4" ASME, 600 lb
Welded flange, 316L stainless steel,
Type A flat faced1)
DN 25, PN 16
DN 25, PN 40
DN 40, PN 16
5N
5P
5Q
DN 40, PN 40
DN 50, PN 16
DN 50, PN 40
6D
6E
6F
DN 80, PN 16
DN 80, PN 40
DN 100, PN 16
DN 100, PN 40
6G
6H
6J
6K
Probe material
19 mm (0.75 inch) diameter 316L stainless steel,
PFA lined rod
3D
5A
5B
5C
Enclosure
Aluminum epoxy coated 2 x ½" NPT via adapter cable inlet, IP65
Aluminum epoxy coated 2 x M20 x 1.5 cable inlet,
IP65
Aluminum epoxy coated 2 x ½" NPT via adapter cable inlet, IP68
Aluminum epoxy coated 2 x M20 x 1.5 cable inlet,
IP68
1)
6A
6B
6C
3 001 ... 4 000 mm (118.15 ... 157.48 inch)
4 001 ... 5 000 mm (157.52 ... 196.85 inch)
D
E
Siemens FI 01 · 2015
0
Dust Ignition Proof With IS Probe
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
Explosion Proof Enclosure With IS Probe
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
3B
A
B
C
4/324
0
1
Approvals
General Safety (CSA, FM, CE, RCM)
Dust Ignition Proof With IS Probe
CE, RCM, ATEX II 1/2 D T100 °C
Flame Proof Enclosure With IS Probe
CE, RCM, ATEX II 1/2 G EEx d [ia] IIC T6...T1,
ATEX II 1/2 D T100 °C
Probe Length
(from flange face or including process thread)
Add Order code Y01 and plain text:
"Insertion length ... mm"
300 ... 1 000 mm (11.81 ... 39.37 inch)
1 001 ... 2 000 mm (39.41 ... 78.74 inch)
2 001 ... 3 000 mm (78.78 ... 118.11 inch)
Thermal isolator
Without thermal isolator
With thermal isolator [for process connection
temperatures over 85 °C (185 °F)]
77 7 77 - 777 0
0
1
Flange bolting patterns and facings dimensionally correspond to the
applicable ASME B16.5 or EN 1092-1 standard.
A
B
C
D
E
A
B
C
D
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC300
Selection and Ordering data
Order code
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
Insertion length, specify in plain text: Y01: ... mm
Y01
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 27 characters) specify in plain text
Y15
Manufacturer's Test Certificate: M to DIN 55350,
Part 18 and to ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Operating Instructions
Article No.
English
7ML1998-5HE03
French
7ML1998-5HE11
German
7ML1998-5HE33
Spanish
7ML1998-5HE21
Multi-language Quick Start manual
Note: The Operating Instructions should be
ordered as a separate line item on the order.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
A5E32268590
4
Accessories
Electronic transmitter kit (includes transmitter and
driver)
7ML1830-1KN
SITRANS RD100, loop powered display see Chapter 7
7ML5741-...
SITRANS RD200, universal input display with
Modbus conversion - see Chapter 7
7ML5740-...
SITRANS RD300, dual line display with totalizer
and linearization curve and Modbus conversion see Chapter 7
7ML5744-...
SITRANS RD500 web, universal remote monitoring
solution for instrumentation - see Chapter 7
7ML5750-...
For applicable back up point level switch see point level measurement section
Siemens FI 01 · 2015
4/325
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC300
Selection and Ordering data
Article No.
Selection and Ordering data
Article No.
SITRANS LC300, stilling well version
An inverse frequency shift capacitance continuous
level transmitter for liquid applications.
7ML5671-
SITRANS LC300, stilling well version
An inverse frequency shift capacitance continuous
level transmitter for liquid applications.
7ML5671-
77 7 77 - 777 0
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Process connection
Threaded, 316L stainless steel
1½" NPT [(Taper), ANSI/ASME B1.20.1]
R 1½" [(BSPT), EN 10226/PT (JIS-T),
JIS B 0203]
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
Welded flange, 316L stainless steel, raised face1)
4
2" ASME, 150 lb
2" ASME, 300 lb
2" ASME, 600 lb
5G
5H
5J
3" ASME, 150 lb
3" ASME, 300 lb
3" ASME, 600 lb
5K
5L
5M
4" ASME, 150 lb
4" ASME, 300 lb
4" ASME, 600 lb
Welded flange, 316L stainless steel,
Type A flat faced1)
DN 40, PN 16
DN 40, PN 40
DN 50, PN 16
5N
5P
5Q
DN 50, PN 40
DN 80, PN 16
DN 80, PN 40
6F
6G
6H
DN 100, PN 16
DN 100, PN 40
1)
4/326
Siemens FI 01 · 2015
D
Order code
Please add "-Z" to Article No. and specify Order
code(s).
6C
6D
6E
6J
6K
D
E
Approvals
General Safety (CSA, FM, CE, RCM)
Dust Ignition Proof With IS Probe
CE, RCM, ATEX II 1/2 D T100 °C
Flame Proof Enclosure With IS Probe
CE, RCM, ATEX II 1/2 G EEx d [ia] IIC T6 ... T1,
ATEX II 1/2 D T100 °C
C
Flange bolting patterns and facings dimensionally correspond to the
applicable ASME B16.5 or EN 1092-1 standard.
Selection and Ordering data
3 001 ... 4 000 mm (118.15 ... 157.48 inch)
4 001 ... 5 000 mm (157.52 ... 196.85 inch)
Probe material
35 mm (1.38 inch) diameter stilling well,
with 19 mm (0.75 inch) diameter 316L
stainless steel, PFA lined rod with PTFE spacers
B
Further designs
A
B
C
Wetted seals
FKM
FFKM [for process temperatures above -20 °C (-4 °F)]
A
Aluminum epoxy coated 2 x M20 x 1.5 cable inlet,
IP68
Probe Length
(from flange face or including process thread)
Add Order code Y01 and plain text:
"Insertion length ... mm"
300 ... 1 000 mm (11.81 ... 39.37 inch)
1 001 ... 2 000 mm (39.41 ... 78.74 inch)
2 001 ... 3 000 mm (78.78 ... 118.11 inch)
Thermal isolator
Without thermal isolator
With thermal isolator [for process connection
temperatures over 85 °C (185 °F)]
E
Enclosure
Aluminum epoxy coated 2 x ½" NPT via adapter cable inlet, IP65
Aluminum epoxy coated 2 x M20 x 1.5 cable inlet,
IP65
Aluminum epoxy coated 2 x ½" NPT via adapter cable inlet, IP68
3D
5D
5E
5F
D
Dust Ignition Proof With IS Probe
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
Explosion Proof Enclosure With IS Probe
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
0D
1D
1½" ASME, 150 lb
1½" ASME, 300 lb
1½" ASME, 600 lb
77 7 77 - 777 0
Insertion length, specify in plain text: Y01: ... mm
Y01
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 27 characters) specify in plain text
Y15
Manufacturer's Test Certificate: M to DIN 55350,
Part 18 and to ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Operating Instructions
Article No.
English
7ML1998-5HE03
French
7ML1998-5HE11
German
7ML1998-5HE33
Spanish
7ML1998-5HE21
Multi-language Quick Start manual
Note: The Operating Instructions should be
ordered as a separate line item on the order.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
7ML1998-5QH81
Accessories
0
1
0
1
1
A
B
C
Electronic transmitter kit
(includes transmitter and driver)
7ML1830-1KN
SITRANS RD100, loop powered display see Chapter 7
7ML5741-...
SITRANS RD200, universal input display with
Modbus conversion - see Chapter 7
7ML5740-...
SITRANS RD300, dual line display with totalizer
and linearization curve and Modbus conversion see Chapter 7
7ML5744-...
SITRANS RD500 web, universal remote monitoring
solution for instrumentation - see Chapter 7
7ML5750-...
For applicable back up point level switch see point level measurement section
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC300
Selection and Ordering data
Article No.
Selection and Ordering data
Article No.
SITRANS LC300, cable version
An inverse frequency shift capacitance continuous
level transmitter for non-conductive liquids and
solids applications.
7ML5672-
SITRANS LC300, cable version
An inverse frequency shift capacitance continuous
level transmitter for non-conductive liquids and
solids applications.
7ML5672-
77 7 77 - 777 0
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Process connection
Threaded, 316L stainless steel
1½" NPT [(Taper), ANSI/ASME B1.20.1]
R 1½" [(BSPT), EN 10226/PT (JIS-T),
JIS B 0203]
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
Welded flange, 316L stainless steel, raised face1)
Approvals
General Safety (CSA, FM, CE, RCM)
Dust Ignition Proof With IS Probe
CE, RCM, ATEX II 1/2 D T100 °C
Flame Proof Enclosure With IS Probe
CE, RCM, ATEX II 1/2 G EEx d [ia] IIC T6...T1,
ATEX II 1/2 D T100 °C
0D
1D
5D
5E
5F
2" ASME, 150 lb
2" ASME, 300 lb
2" ASME, 600 lb
5G
5H
5J
3" ASME, 150 lb
3" ASME, 300 lb
3" ASME, 600 lb
5K
5L
5M
4" ASME, 150 lb
4" ASME, 300 lb
4" ASME, 600 lb
Welded flange, 316L stainless steel,
Type A flat faced1)
DN 40, PN 16
DN 40, PN 40
DN 50, PN 16
5N
5P
5Q
DN 50, PN 40
DN 80, PN 16
DN 80, PN 40
6F
6G
6H
DN 100, PN 16
DN 100, PN 40
6J
6K
6C
6D
6E
6 001 ... 8 000 mm (236.26 ... 314.96 inch)
8 001 ... 10 000 mm (315.00 ... 393.70 inch)
10 001 ... 12 000 mm (393.74 ... 472.44 inch)
D
E
F
12 001 ... 14 000 mm (472.48 ... 551.18 inch)
14 001 ... 16 000 mm (551.22 ... 629.92 inch)2)
16 001 ... 18 000 mm (629.96 ... 708.66 inch)2)
G
H
J
18 001 ... 20 000 mm (708.70 ... 787.40 inch)2)
20 001 ... 22 000 mm (787.44 ... 866.14 inch)2)
22 001 ... 24 000 mm (866.18 ... 944.88 inch)2)
K
L
M
24 001 ... 25 000 mm (944.92 ... 984.25 inch)2)
N
Probe material
Bare 316L stainless steel cable and 316L
stainless steel cable weight, tinned copper crimp,
PTFE backing ring, PEEK isolator and PFA lined
active shield
D
E
4
A
B
C
D
Aluminum epoxy coated 2 x M20 x 1.5 cable inlet,
IP68
A
B
C
Wetted seals
FKM
FFKM [for process temperatures above
-20 °C (-4 °F)]
C
Enclosure
Aluminum epoxy coated 2 x ½" NPT via adapter cable inlet, IP65
Aluminum epoxy coated 2 x M20 x 1.5 cable inlet,
IP65
Aluminum epoxy coated 2 x ½" NPT via adapter cable inlet, IP68
Probe Length
(from flange face or including process thread)
Add Order code Y01 and plain text:
"Insertion length ... mm"
1 000 ... 2 000 mm (39.37 ... 78.74 inch)
2 001 ... 4 000 mm (78.78 ... 157.48 inch)
4 001 ... 6 000 mm (157.52 ... 236.22 inch)
Thermal isolator
Without thermal isolator
With thermal isolator [for process connection
temperatures over 85 °C (185 °F)]
A
B
Dust Ignition Proof With IS Probe
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
Explosion Proof Enclosure With IS Probe
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
3D
1½" ASME, 150 lb
1½" ASME, 300 lb
1½" ASME, 600 lb
77 7 77 - 777 0
1)
Flange bolting patterns and facings dimensionally correspond to the
applicable ASME B16.5 or EN 1092-1 standard.
2)
Cable lengths from 15 000 mm (590.55 inch) to 25 000 mm (984.25 inch)
can be used in non-conductive media. Contact Factory for assistance.
0
1
0
1
0
Siemens FI 01 · 2015
4/327
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC300
Selection and Ordering data
Order code
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
4
Insertion length, specify in plain text: Y01: ... mm
Y01
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 27 characters) specify in plain text
Y15
Manufacturer's Test Certificate: M to DIN 55350,
Part 18 and to ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Operating Instructions
Article No.
English
7ML1998-5HE03
French
7ML1998-5HE11
German
7ML1998-5HE33
Spanish
7ML1998-5HE21
Multi-language Quick Start manual
Note: The Operating Instructions should be
ordered as a separate line item on the order.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
7ML1998-5QH81
Accessories
Electronic transmitter kit (includes transmitter
and driver)
7ML1830-1KN
SITRANS RD100, loop powered display see Chapter 7
7ML5741-...
SITRANS RD200, universal input display with
Modbus conversion - see Chapter 7
7ML5740-...
SITRANS RD300, dual line display with totalizer
and linearization curve and Modbus conversion see Chapter 7
7ML5744-...
SITRANS RD500 web, universal remote monitoring
solution for instrumentation - see Chapter 7
7ML5750-...
For applicable back up point level switch see point level measurement section
4/328
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC300
Selection and Ordering data
Article No.
Selection and Ordering data
Article No.
SITRANS LC300, PFA coated cable version
An inverse frequency shift capacitance continuous
level transmitter for liquids and solids applications.
7ML5673-
SITRANS LC300, PFA coated cable version
An inverse frequency shift capacitance continuous
level transmitter for liquids and solids applications.
7ML5673-
77 7 77 - 777 7
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Process connection
Threaded, 316L stainless steel
1½" NPT [(Taper), ANSI/ASME B1.20.1]
R 1½" [(BSPT), EN 10226/PT (JIS-T),
JIS B 0203]
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
Welded flange, 316L stainless steel, raised face1)
Probe material
PFA coated cable and 316L stainless steel cable
weight, PEEK isolator and PFA lined active shield
3D
5D
5E
5F
2" ASME, 150 lb
2" ASME, 300 lb
2" ASME, 600 lb
5G
5H
5J
3" ASME, 150 lb
3" ASME, 300 lb
3" ASME, 600 lb
5K
5L
5M
4" ASME, 150 lb
4" ASME, 300 lb
4" ASME, 600 lb
Welded flange, 316L stainless steel,
Type A flat faced1)
DN 40, PN 16
DN 40, PN 40
DN 50, PN 16
5N
5P
5Q
DN 50, PN 40
DN 80, PN 16
DN 80, PN 40
6F
6G
6H
Flame Proof Enclosure With IS Probe
CE, RCM, ATEX II 1/2 G EEx d [ia] IIC T6...T1,
ATEX II 1/2 D T100 °C
C
Dust Ignition Proof With IS Probe
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
Explosion Proof Enclosure With IS Probe
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
D
A
B
C
D
Mounting eye
Without Mounting eye
With mounting eye
6J
6K
6 001 ... 8 000 mm (236.26 ... 314.96 inch)
8 001 ... 10 000 mm (315.00 ... 393.70 inch)
10 001 ... 12 000 mm (393.74 ... 472.44 inch)
D
E
F
12 001 ... 14 000 mm (472.48 ... 551.18 inch)
14 001 ... 16 000 mm (551.22 ... 629.92 inch)2)
16 001 ... 18 000 mm (629.96 ... 708.66 inch)2)
G
H
J
18 001 ... 20 000 mm (708.70 ... 787.40 inch)2)
20 001 ... 22 000 mm (787.44 ... 866.14 inch)2)
22 001 ... 24 000 mm (866.18 ... 944.88 inch)2)
K
L
M
24 001 ... 25 000 mm (944.92 ... 984.25 inch)2)
N
4
E
Aluminum epoxy coated 2 x M20 x 1.5 cable inlet,
IP68
6C
6D
6E
A
B
C
Wetted seals
FKM
FFKM [for process temperatures above -20 °C
(-4 °F)]
A
B
Enclosure
Aluminum epoxy coated 2 x ½" NPT via adapter cable inlet, IP65
Aluminum epoxy coated 2 x M20 x 1.5 cable inlet,
IP65
Aluminum epoxy coated 2 x ½" NPT via adapter cable inlet, IP68
Probe Length
(from flange face or including process thread)
Add Order code Y01 and plain text:
"Insertion length ... mm"
1 000 ... 2 000 mm (39.37 ... 78.74 inch)
2 001 ... 4 000 mm (78.78 ... 157.48 inch)
4 001 ... 6 000 mm (157.52 ... 236.22 inch)
Thermal isolator
Without thermal isolator
With thermal isolator [for process connection
temperatures over 85 °C (185 °F)]
1
Approvals
General Safety (CSA, FM, CE, RCM)
Dust Ignition Proof With IS Probe
CE, RCM, ATEX II 1/2 D T100 °C
0D
1D
1½" ASME, 150 lb
1½" ASME, 300 lb
1½" ASME, 600 lb
DN 100, PN 16
DN 100, PN 40
77 7 77 - 777 7
0
1
1)
Flange bolting patterns and facings dimensionally correspond to the
applicable ASME B16.5 or EN 1092-1 standard.
2)
Cable lengths from 15 000 mm (590.55 inch) to 25 000 mm (984.25 inch)
can be used in non-conductive media. Contact Factory for assistance.
0
1
0
1
Siemens FI 01 · 2015
4/329
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC300
Selection and Ordering data
Order code
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
4
Insertion length, specify in plain text: Y01: ... mm
Y01
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 27 characters) specify in plain text
Y15
Manufacturer's Test Certificate: M to DIN 55350,
Part 18 and to ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Operating Instructions
Article No.
English
7ML1998-5HE03
French
7ML1998-5HE11
German
7ML1998-5HE33
Spanish
7ML1998-5HE21
Multi-language Quick Start manual
7ML1998-5QH81
Note: The Operating Instructions should be
ordered as a separate line item on the order.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
Accessories
Electronic transmitter kit (includes transmitter
and driver)
7ML1830-1KN
SITRANS RD100, loop powered display see Chapter 7
7ML5741-...
SITRANS RD200, universal input display with
Modbus conversion - see Chapter 7
7ML5740-...
SITRANS RD300, dual line display with totalizer
and linearization curve and Modbus conversion see Chapter 7
7ML5744-...
SITRANS RD500 web, universal remote monitoring
solution for instrumentation - see Chapter 7
7ML5750-...
For applicable back up point level switch see point level measurement section
4/330
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC300
■ Characteristic curves
Pressure/temperature curve
LC300 standard, extended rod and cable probes
Threaded process connections
(7ML5670, 7ML5671, 7ML5672 and 7ML5673)
Permitted operating pressures P
40 bar (580 psi)
30 bar (435 psi)
20 bar (290 psi)
Atmospheric
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
4
10 bar (145 psi)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
-29 ºC
(-20 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
Permitted operating temperature T
Example:
ermitted operating pressure = 30 bar (435 psi) at 75 °C
SITRANS LC300 Process Pressure/Temperature derating curves (7ML5625)
Siemens FI 01 · 2015
4/331
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC300
Pressure/temperature curve
LC300 standard, extended rod and cable probes
ASME flanged process connections
(7ML5670, 7ML5671, 7ML5672 and 7ML5673)
Permitted operating pressures P
90 bar (1.305 psi)
80 bar (1.160 psi)
70 bar (1.015 psi)
60 bar (870 psi)
4
ASME 6001)
50 bar (725 psi)
40 bar (580 psi)
30 bar (435 psi)
ASME 3001)
20 bar (290 psi)
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
ASME 1501)
10 bar (145 psi)
Atmospheric
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
-29 ºC
(-20 ºF)
1)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted operating temperature T
The curve denotes the minimum allowable flange class for the shaded area below.
SITRANS LC300 Process Pressure/Temperature derating curves (7ML5626)
Pressure/temperature curve
LC300 standard, extended rod and cable probes
EN flanged process connections
(7ML5670, 7ML5671, 7ML5672 and 7ML5673)
Permitted operating pressures P
40 bar (580 psi)
30 bar (435 psi)
PN 401)
20 bar (290 psi)
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
PN 161)
10 bar (145 psi)
Atmospheric
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
-29 ºC
(-20 ºF)
1)
The curve denotes the minimum allowable flange class for the shaded area below.
SITRANS LC300 Process Pressure/Temperature derating curves (7ML5626)
4/332
Siemens FI 01 · 2015
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted operating temperature T
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC300
■ Dimensional drawings
Threaded (7ML5670)
Threaded (7ML5671)
Lid
2 cable entries
1/2" NPT or
M20 x 1.5
Stainless steel
stilling well
Measuring length
Vent
PFA
insulated
probe
Ø19 (0.75)
Y01 (insertion length)
min. = 300 (14) / max. = 5 000 (197)
Y02 1)
M20: 135 (5.32)
1/2" NPT: 150
(5.91)
Lid without window
Thermal
isolator
Note:
1) Rod version Y02: Shield length = 100 mm
(3.9 inch) for threaded including process
connection thread length, 100 mm
(3.9 inch) for welded flange
2) For non-conductive applications only.
Non-insulated cable can be shortened on
site. Weight is included in measuring
length.
3) For liquids and solids applications.
Insulated cable cannot be shortened.
Weight is not included in measuring
length.
4) For conductive materials, the measuring
length includes the exposed PFA insulated
cable only. Any fluid contact with the upper
rod assembly will result in a short circuit
and incorrect readings.
*
*
PFA
insulated
probe
Y01 (insertion length)
min. = 300 (14) / max. = 5 000 (197)
Measuring length
Y02 1)
20 (0.79)
Ø35 (1.38)
Ø19 (0.75)
* = 30 (1.18) Inactive tip
Cable version, non-insulated
Threaded (7ML5672)
2)
Cable version, insulated
Threaded (7ML5673)
275 (10.83)
Electronics/
enclosure
150
(5.91)
Lid clip
3)
Ø32 (1.26)
Stainless steel
weight (electrically
isolated but not
PFA insulated),
actual weight =
(2.15 kg [4.76 lb])
350 (13.78)
Ø9 (0.35)
Ø34,5 (1.36)
Mounting eye
Ø12
(0.47)
Ø25 (0.98)
20 (0.79)
Ø9 (0.35)
See
note 4
Y01 (insertion length)
min. = 1 000 (40) / max. = 25 000 (984)
Y02 =
105
(4.13)
Measuring
length
PFA insulated
cable
350 (13.78)
Stainless steel
weight, actual
weight = (1.27 kg
[2.80 lb])
250 (9.84)
Ø6 (0.24)
Y01 (insertion length)
min. = 1 000 (40) / max. = 25 000 (984)
Stainless steel
cable
Measuring length
Y02 =
105
(4.13)
20 (0.79)
Ø34,5 (1.36)
SITRANS LC300 - Threaded Process Connections, dimensions in mm (inch)
Siemens FI 01 · 2015
4/333
4
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC300
Welded Flange (7ML5670)
Welded Flange (7ML5671)
2 cable entries
½" NPT or
M20 x 1.5
Lid
Lid clip
Electronics/
enclosure
M20: 135 (5.32)
1/2" NPT: 150 (5.91)
PFA
insulated
probe
Ø19 (0.75)
150
(5.91)
Thermal
isolator
Flange Facing (raised face)
Flange Class
2 (0.08)
ASME 600/900
7 (0.28)
PN16/40
2 (0.08)
Ø32 (1.26)
Stainless steel
weight (electrically
isolated but not PFA
insulated)
Ø34,5 (1.36)
Ø9 (0.35)
350 (13.78)
See
note 4
Y01 (insertion length)
min. = 1 000 (40) / max. = 25 000 (984)
Y02 =
105
(4.13)
Ø9 (0.35)
SITRANS LC300 - Flanged Process Connections, dimensions in mm (inch)
Siemens FI 01 · 2015
Measuring
length
PFA insulated
cable
350 (13.78)
Ø6 (0.24)
Cable version, insulated 3)
Welded Flange (7ML5673)
Y01 (insertion length)
min. = 1 000 (40) / max. = 25 000 (984)
Stainless steel
cable
Measuring length
Y02 =
105
(4.13)
Cable version, non-insulated 2)
Welded Flange (7ML5672)
Ø34,5 (1.36)
Mounting eye
Ø12
(0.47)
Ø25 (0.98)
20 (0.79)
*
* = 30 (1.18) inactive tip
4/334
Facing thickness
ASME 150/300
Notes:
1) Rod version Y02: Shield length = 100 mm
(3.9 inch) for threaded including process
connection thread length, 100 mm
(3.9 inch) for welded flange.
2) For non-conductive applications only.
Non-insulated cable can be shortened on
site. Weight is included in measuring
length.
3) For liquids and solids applications.
Insulated cable cannot be shortened.
Weight is not included in measuring
length.
4) For conductive materials, the measuring
length includes the exposed PFA insulated
cable only. Any fluid contact with the upper
rod assembly will result in a short circuit
and incorrect readings.
Ø35 (1.38)
Ø19 (0.75)
Stainless steel
weight
275 (10.83)
Measuring length
Vent
Y01 (insertion length)
min. = 300 (14) / max. = 5 000 (197)
Y02 1)
Stainless steel
stilling well
*
Y01 (insertion length)
min. = 300 (14) / max. = 5 000 (197)
Y02 1)
Measuring length
PFA
insulated
probe
250 (9.84)
4
Lid without window
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC300
■ Schematics
With safety barrier
Without safety barrier
white (S)
orange (S)
black (O)
black (O)
red (+)
red (+)
For factory software
update use only
Menu / function selector
4 ... 20 mA (2-wire) current loop
measurement signal (not polarity
sensitive)
4
Down / - button
Up / + button
SITRANS LC300 connections
Siemens FI 01 · 2015
4/335
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500
■ Overview
■ Configuration
Installation
Build up of material or condensation in active shield area
does not affect switch operation.
4
SITRANS LC500 is an inverse frequency shift capacitance level
or interface transmitter for extreme and critical process conditions, such as oil and liquified natural gas (LNG) as well as toxic
and aggressive chemicals and vapors.
■ Benefits
• Patented Active-Shield technology so measurement is
unaffected by material buildup in active shield section
• Simple push-button calibration and integrated local display
• Inverse frequency approach provides high resolution
• 2-wire loop powered 4 to 20/20 to 4 mA measurement signal
• Pre-detection alarm and full function diagnostics
• High temperature and pressure resistant (optional)
• Full-function diagnostics comply with NAMUR NE 43
• Easy calibration locally or via HART (using SIMATIC PDM
software)
■ Application
Mounting on non-linear vessels in non-conductive fluids
using stilling well.
SITRANS LC500 installation, dimensions in mm (inch)
■ Technical specifications
Input
Measuring range
1 ... 3 300 pF
Span
Min. 3.3 pF
Output
Solid-state switch
SITRANS LC500’s advanced electronics provide one-step,
push-button calibration and local display for easy on-site installation and setup.
• Output
Galvanically isolated
• Protection
Bipolar
The unique mechanical probe design coupled with a high
performance transmitter gives superior performance in toxic
and aggressive chemicals, acids, caustics, adhesives and in
viscous conductive and non-conductive materials.
• Max. switching voltage
• 30 V (DC)
• 30 V peak (AC)
• Max. load current
82 mA
• Voltage drop
< 1 V, typical at 50 mA
The SMART 2-wire transmitter has HART communications for remote commissioning and inspection.
• Key Applications: Oil/water or foam/liquid interface
measurement in separators or coalescers, cryogenic applications including C02 and liquified natural gas (LNG), distillation/
regeneration tanks with high temperatures
• Time delay (pre or post switching)
1 ... 60 s
Loop current
3.6 ... 22 mA/22 ... 3.6 mA
(2-wire current loop)
4/336
Siemens FI 01 · 2015
Accuracy (transmitter)
Temperature stability
0.15 pF (0 pF) or < 0.25 %
(typically < 0.1 %) of actual measured value, whichever is greater
over the full temperature range
Non-linearity and repeatability
< 0.1 % of range and actual
measured value respectively
Accuracy
Deviation < 0.1 % of measured value
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500
Rated operating conditions1)
Power supply
Installation conditions
User Interface
• Location
12 ... 33 V DC
Indoor/outdoor
Display
Local LCD, 4 digit, each 0 ... 9 and
limited alpha characters
• Ambient temperature (transmitter)
-40 ... +85 °C (-40 ... +185 °F)2)
Rotary function switch
For selecting programmable menu
items
• Installation category
II
Push buttons
• Pollution degree
4
Red +, blue -, used in conjunction
with rotary switch for
programming
Ambient conditions
Medium conditions
Features
• Relative dielectric constant r
Min. 1.5
• Process temperature
Temperature rating of process seal is
pressure dependent.
See Pressure/Temperature curves on
page 4/346.
- Standard (PFA)
3)
- Cryogenic version
Measurement current signaling
According to NAMUR NE 43,
signal 3.8 ... 20.5 mA, fault  3.6 or
 21 mA (22 mA)
Safety
• Inputs/outputs fully galvanically
isolated
• Polarity-insensitive current loop
• Fully potted
• Integrated safety barrier
Diagnostics with fault alarm when:
Primary variable (PV) out of limits,
system failure in measurement circuit,
deviation between A/D and D/A converter, check sum, watch dog and
self-checking facility
Function rotary switch
Positions 0 ... 9, A ... F
SMART communication
Conforming to HART Communication
Foundation (HCF)
-50 ... +200 °C (-58 ... +392 °F)
-200 ... +200 °C (-328 ... +392 °F)
Contact [email protected] for
details.
• Process pressure
Pressure rating of process seal is
temperature dependent.
See Pressure/Temperature curves on
page 4/346.
• Standard (PFA)
-1 ... 150 bar g (2175 psi g)
Design
Material
Certificates and approvals
• Wetted parts material
- Standard rod
General Purpose
CE, CSA, FM, RCM
Non-incendive/Non-sparking
• CSA/FM Class 1, Div. 2, Groups A,
B, C, D T4 ATEX II 3G 2D EEx nA [ib]
IIC
• Probe insulation (rod)
• Cable
316L stainless steel
PFA
316 stainless steel/
316 stainless steel PFA
Probe diameter
• Rod version
16 mm (0.63 inch) or 24 mm
(0.95 inch)
• Cable version
9 mm (0.35 inch) with PFA jacket,
6 mm (0.24 inch) without PFA jacket
Active shield length
• Minimum (rod version)
• T6 ... T4 T100 °C
Dust Ignition Proof
(Intrinsically Safe Probe Circuit)
• CSA/FM Class II and III, Div. 1,
Groups E, F, G
• ATEX II 1/2 GD EEx d [ia] T6 to T1
T100 °C
Explosion Proof
(Intrinsically Safe Probe Circuit)
• FM Class 1, Div. 1, Groups A, B, C, D
T4
• ATEX II 1/2 GD EEx d [ia] IIC T6 to T1
50 mm (1.97 inch), customer selectable (order number Y02)
Marine
Probe length
• Rod version
Max. 3.5 m (138 inch) with 16 mm
rod, PFA
Max. 5.5 m (216 inch) with 24 mm
rod, PFA
• Cable version
Max. 35 m (1 378 inch)
Process connection of probe
• Threaded mounting
NPT [(Taper), ANSI/ASME B1.20.1]
R [(BSPT), EN 10226/PT (JIS-T),
JIS B 0203]
G [(BSPP), EN ISO 228-1/
PF (JIS-P), JIS B 0202]
• Flange mounting
ASME, EN 1092-1
Lloyds Register of Shipping,
Categories ENV1, ENV2, ENV3 and
ENV5, Bureau Veritas
1)
When operation is in areas classified as hazardous, observe restrictions
according to relevant certificate. See also Pressure/Temperature curves on
page 4/346.
2)
Thermal isolator is used if process connection temperature exceeds 85 °C
(185 °F).
3)
Not recommended for steam environments
Enclosure
• Material
Aluminum, epoxy-coated
• Cable inlet
2 x ½ inch NPT (2 x M20x1.5,
IP68 adapter, optional)
• Degree of protection
Type 4X/NEMA4X/IP65, IP68
Siemens FI 01 · 2015
4/337
4
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500
SITRANS LC500 probe version
Standard
Extended Cable version with
Rod Sensor
Process connection types
Threaded or welded flange
Single piece flanged
Threaded or welded flange
Threaded
Available as standard
–
Available as standard
Flange
Available as standard
Available as standard
Available as standard
Available as standard
Available as standard
Available as standard
Available as standard
Available as standard
Available as standard
Rod length for PFA 16 mm version
Min. 200 mm (7.87 inch)
Max. 3 500 mm (137.80 inch)
Min. 200 mm (7.87 inch)
Max. 3 500 mm (137.80 inch)
Min. 200 mm (7.87 inch)
Max. 3 500 mm (137.80 inch)
Rod length for PFA 24 mm version
Min. 200 mm (7.87 inch)
Max. 5 500 mm (216.54 inch)
Min. 200 mm (7.87 inch)
Max. 5 500 mm (216.54 inch)
Min. 200 mm (7.87 inch)
Max. 5 500 mm (216.54 inch)
Cable length
Min. 1 000 mm (39.37 inch)
Max. 35 000 mm (1 377.95 inch)
Min. 1 000 mm (39.37 inch)
Max. 35 000 mm (1 377.95 inch)
Min. 5 000 mm (196.85 inch)2)
Max. 35 000 mm (1 377.95 inch)2)
Maximum process pressure
See Pressure/Temperature curves for specific probe type
Process connection materials
Stainless steel 316L
Probe insulation
PFA
Length and Process parameters1)
4
Maximum process temperature
5 bar g (73 psi g)
100 °C (212 °F)
1)
See Pressure/Temperature curves for specific probe type
2)
Refers to total insertion length. See dimension drawing on page 4/354 for further explanation - Not available as standard
4/338
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500
Selection and Ordering data
SITRANS LC500, Threaded or Welded Flange
with Cable Sensor
Inverse frequency shift capacitance level and
interface transmitter for extreme and critical
process conditions, such as oil and liquid gas,
toxic and aggressive chemicals and vapours.
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Version1)
Cable, 9 mm (0.35 inch) diameter, 316 stainless
steel with PFA insulation, weighted
Add Order code Y01 and plain text:
"Insertion length ... mm"
1 000 ... 2 000 mm (39.37 ... 78.74 inch)
2 001 ... 4 000 mm (78.78 ... 157.48 inch)
4 001 ... 6 000 mm (157.52 ... 236.22 inch)
6 001 ... 8 000 mm (236.26 ... 314.96 inch)
8 001 ... 10 000 mm (315 ... 393.70 inch)
Longer lengths possible to a max. of 35 000 mm
(114.83 ft). Contact [email protected] for
details.
Cable, 6 mm (0.24 inch) diameter, 316L stainless
steel, non-insulated, weighted (non-conductive
media only)
Add Order code Y01 and plain text:
"Insertion length ... mm"
1 000 ... 2 000 mm (39.37 ... 78.74 inch)2)
2 001 ... 4 000 mm (78.78 ... 157.48 inch)2)3)
4 001 ... 6 000 mm (157.52 ... 236.22 inch)2)3)
6 001 ... 8 000 mm (236.26 ... 314.96 inch)2)3)
8 001 ... 10 000 mm (315 ... 393.70 inch)2)3)
Cable lengths up to 25 000 mm (984.25 inch) are
possible for non-conductive media. Cable lengths
up to 15 000 mm (590.55 inch) are possible for
conductive media.
Contact [email protected] for details.
Process connection (316L stainless steel)
Threaded connection
1½" NPT [(Taper), ANSI/ASME B1.20.1]
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
Welded flange, raised face
1½", ASME, 150 Ib
1½", ASME, 300 Ib
1½", ASME, 600 Ib
2", ASME, 150 Ib
2", ASME, 300 Ib
2", ASME, 600 Ib
3", ASME, 150 Ib3)
3", ASME, 300 Ib3)
3", ASME, 600 Ib3)
4", ASME, 150 Ib3)
4", ASME, 300 Ib3)
4", ASME, 600 Ib3)
6", ASME, 150 Ib3)
6", ASME, 300 Ib3)
6", ASME, 600 Ib3)
Article No.
7ML551377 7 77 - 77 77
0E
1E
2E
3E
4E
0F
1F
2F
3F
4F
C0
F0
K0
L0
B1
B2
B3
C1
C2
C3
D1
D2
D3
E1
E2
E3
F1
F2
F3
Selection and Ordering data
SITRANS LC500, Threaded or Welded Flange
with Cable Sensor
Inverse frequency shift capacitance level and
interface transmitter for extreme and critical
process conditions, such as oil and liquid gas,
toxic and aggressive chemicals and vapours.
Approvals
General Purpose: CE, CSA, FM, RCM
CSA / FM Class I, Div. 2, Groups A, B, C, D
CSA / FM Class II, III, Div. 1, Groups E, F, G T4
ATEX II 3G 2D EEx nA [ib] IIC T6 ... T4 T 100 °C
ATEX II 1/2 GD EEx d [ia] IIC T6 ... T1 T 100 °C
FM Class I, Div.1, Groups A, B, C, D, T4
Enclosure/Cable inlet
Aluminum epoxy coated
2 x ½" NPT, IP68
2 x M20x1.5 (IP68, adapter)
Options
No additional options
With mounting eye4)
Thermal isolator
Without thermal isolator
Isolator, only for use when temperature range is
outside of -40 ... +85 °C (-40 ... +185 °F),
explosion proof approval -40 ... +70 °C
(-40 ... +158 °F)
Electronic output
2-wire loop current 4 ... 20 mA
(transmitter MSP 2002-2 _3300 pF)
Article No.
7ML55137 7 7 77 - 77 7 7
1
2
4
6
1
2
4
A
B
A
B
1
1)
A minimum span of 3 pF must be maintained
2)
Available with non-conductive media only
3)
Custom shipping methods required. Contact factory for more details.
4)
Available in PFA insulated version only
Order code
Selection and Ordering data
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
Insertion length, specify in plain text: Y01: ... mm
Y01
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 27 characters) specify in plain text
Y15
Manufacturer's test certificate: M to DIN 55350,
Part 18 and to ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Operating Instructions
See page 4/345
Accessories
See page 4/345
Welded flange, Type A flat faced
DN 40, PN 16
DN 40, PN 40
DN 50, PN 16
DN 50, PN 40
DN 80, PN 16
DN 80, PN 403)
DN 100, PN 163)
DN 100, PN 403)
DN 125, PN 163)
DN 125, PN 403)
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5, or EN 1092-1 standard.)
K4
K5
L4
L5
M4
M5
N4
N5
P4
P5
Siemens FI 01 · 2015
4/339
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500
4
Selection and Ordering data
SITRANS LC500, Threaded or Welded Flange,
with Rod Sensor
Inverse frequency shift capacitance level and
interface transmitter for extreme and critical
process conditions, such as oil and liquid gas,
toxic and aggressive chemicals and vapours.
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Version
Rod, 16 mm (0.63 inch), PFA insulated
Add Order code Y01 and Y02 and plain text:
"Insertion length ... mm and active shield
length ... mm"
200 ... 1 000 mm (7.87 ... 39.37 inch)1)
1 001 ... 2 000 mm (39.41 ... 78.74 inch)
2 001 ... 3 000 mm (78.78 ... 118.11 inch)2)
3 001 ... 3 500 mm (118.15 ... 137.80 inch)2)
Rod, 16 mm (0.63 inch), PFA insulated with 35 mm
(1.38 inch) stilling well in 316L stainless steel
Add Order code Y01 and Y02 and plain text:
"Insertion length ... mm and active shield
length ... mm"
200 ... 1 000 mm (7.87 ... 39.37 inch)1)3)
1 001 ... 2 000 mm (39.41 ... 78.74 inch)3)
2 001 ... 3 000 mm (78.78 ... 118.11 inch)2)3)
3 001 ... 3 500 mm (118.15 ... 137.80 inch)2)3)
Rod, 24 mm (0.94 inch), PFA insulated
Add Order code Y01 and Y02 and plain text:
"Insertion length ... mm and active shield
length ... mm"
200 ... 1 000 mm (7.87 ... 39.37 inch)4)
1 001 ... 2 000 mm (39.41 ... 78.74 inch)4)
2 001 ... 3 000 mm (78.78 ... 118.11 inch)2)4)
3 001 ... 4 000 mm (118.15 ... 157.48 inch)2)4)
4 001 ... 5 000 mm (173.26 ... 196.88 inch)2)4)
5 001 ... 5 500 mm (196.89 ... 216.54 inch)2)4)
Rod, 24 mm (0.94 inch), PFA insulated with 48 mm
(1.89 inch) stilling well in 316L stainless steel
Add Order code Y01 and Y02 and plain text:
"Insertion length ... mm and active shield
length ... mm"
200 ... 1 000 mm (7.87 ... 39.37 inch)5)
1 001 ... 2 000 mm (39.41 ... 78.74 inch)5)
2 001 ... 3 000 mm (78.78 ... 118.11 inch)2)5)
3 001 ... 4 000 mm (118.15 ... 157.48 inch)2)5)
4 001 ... 5 000 mm (173.26 ... 196.88 inch)2)5)
5 001 ... 5 500 mm (196.89 ... 216.54 inch)2)5)
Process connection (316L stainless steel)
Threaded connection
¾" NPT [(Taper), ANSI/ASME B1.20.1]
1" NPT [(Taper), ANSI/ASME B1.20.1]
1½" NPT [(Taper), ANSI/ASME B1.20.1]
2" NPT [(Taper), ANSI/ASME B1.20.1]
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
R 2" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
G 2" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
4/340
Siemens FI 01 · 2015
Article No.
7ML551577 7 77 - 77 77
0A
1A
2A
3A
0B
1B
2B
3B
0C
1C
2C
3C
4C
5C
0D
1D
2D
3D
4D
5D
A0
B0
C0
D0
E0
F0
J0
K0
N0
P0
R0
S0
T0
Selection and Ordering data
SITRANS LC500, Threaded or Welded Flange,
with Rod Sensor
Inverse frequency shift capacitance level and
interface transmitter for extreme and critical
process conditions, such as oil and liquid gas,
toxic and aggressive chemicals and vapours.
Welded flange, raised face
1½", ASME, 150 Ib
1½", ASME, 300 Ib
1½", ASME, 600 Ib
2", ASME, 150 Ib
2", ASME, 300 Ib
2", ASME, 600 Ib
3", ASME, 150 Ib2)
3", ASME, 300 Ib2)
3", ASME, 600 Ib2)
4", ASME, 150 Ib2)
4", ASME, 300 Ib2)
4", ASME, 600 Ib2)
6", ASME, 150 Ib2)
6", ASME, 300 Ib2)
6", ASME, 600 Ib2)
Welded flange, Type A flat faced
DN 40, PN 16
DN 40, PN 40
DN 50, PN 16
DN 50, PN 40
DN 80, PN 16
DN 80, PN 402)
DN 100, PN 162)
DN 100, PN 402)
DN 125, PN 162)
DN 125, PN 402)
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5, or EN 1092-1 standard.)
Approvals
General Purpose: CE, CSA, FM, RCM
CSA / FM Class I, Div. 2, Groups A, B, C, D
CSA / FM Class II, III, Div. 1, Groups E, F, G T4
ATEX II 3G 2D EEx nA [ib] IIC T6 ... T4 T 100 °C
ATEX II 1/2 GD EEx d [ia] IIC T6 ... T1 T 100 °C
FM Class I, Div.1, Groups A, B, C, D, T4
Enclosure/Cable inlet
Aluminum epoxy coated
2 x ½" NPT, IP68
2 x M20 x1.5 (IP68, adapter)
Options
No additional options
Slotted holes instead of standard vent holes in
stilling well (refer to Operating Instructions for
dimensions.)6)
Thermal isolator/remote version
Without thermal isolator or remote electronics
Thermal isolator, only for use when temperature
range is outside of -40 ... +85 °C (-40 ... +185 °F),
explosion proof approval -40 ... +70 °C
(-40 ... +158 °F)
Remote electronics with mounting bracket and
cable7)
• Length: 2 m (79 inch)
• Length: 3 m (118 inch)
• Length: 4 m (158 inch)
• Length: 5 m (197 inch)
Article No.
7ML55157 7 7 77 - 77 7 7
B1
B2
B3
C1
C2
C3
D1
D2
D3
E1
E2
E3
F1
F2
F3
K4
K5
L4
L5
M4
M5
N4
N5
P4
P5
1
2
4
6
1
2
A
B
A
B
C
D
E
F
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500
Selection and Ordering data
SITRANS LC500, Threaded or Welded Flange,
with Rod Sensor
Inverse frequency shift capacitance level and
interface transmitter for extreme and critical
process conditions, such as oil and liquid gas,
toxic and aggressive chemicals and vapours.
Electronic output
2-wire loop current 4 ... 20 mA
(transmitter MSP 2002-2 _3300 pF)
Article No.
7ML5515-
Order code
Selection and Ordering data
Further designs
77 7 77 - 77 77
1
Please add "-Z" to Article No. and specify Order
code(s).
Insertion length, specify in plain text: Y01: ... mm
Y01
Active shield length, specify in plain text
[min. length is 50 mm (2 inch)]: Y02: ... mm
Y02
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 27 characters) specify in plain text
Y15
Manufacturer's test certificate: M to DIN 55350,
Part 18 and to ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
1)
A minimum span of 3 pF must be maintained
2)
Custom shipping methods required. Contact factory for more details.
3)
Available with process connection 1½" or larger
4)
Available with process connection 1" or larger
5)
Available with process connection 2 " or larger
6)
Available with version 0B … 3B, 0D … 5D and 0F only
Manufacturing Test Report (Electrode Test)
C18
7)
Available with approval option 1 only
Operating Instructions
See page 4/345
Accessories
See page 4/345
Siemens FI 01 · 2015
4/341
4
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500
4
Selection and Ordering data
SITRANS LC500, Single Piece Flanged with
Rod Sensor
Inverse frequency shift capacitance level and
interface transmitter for extreme and critical
process conditions, such as oil and liquid gas,
toxic and aggressive chemicals and vapours.
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Version
Rod, 16 mm (0.63 inch), PFA insulated
Add Order code Y01 and Y02 and plain text:
"Insertion length ... mm and active shield
length ... mm"
250 ... 1 000 mm (9.84 ... 39.37 inch)1)
1 001 ... 2 000 mm (39.41 ... 78.74 inch)
2 001 ... 3 000 mm (78.78 ... 118.11 inch)2)
3 001 ... 3 500 mm (118.15 ... 137.80 inch)2)
Rod, 16 mm (0.63 inch), PFA insulated with 35 mm
(1.34 inch) stilling well in 316L stainless steel
Add Order code Y01 and Y02 and plain text:
"Insertion length ... mm and active shield
length ... mm"
250 ... 1 000 mm (9.84 ... 39.37 inch)
1 001 ... 2 000 mm (39.41 ... 78.74 inch)
2 001 ... 3 000 mm (78.78 ... 118.11 inch)2)
3 001 ... 3 500 mm (118.15 ... 137.80 inch)2)
Rod, 24 mm (0.94 inch), PFA insulated
Add Order code Y01 and Y02 and plain text:
"Insertion length ... mm and active shield
length ... mm"
250 ... 1 000 mm (9.84 ... 39.37 inch)
1 001 ... 2 000 mm (39.41 ... 78.74 inch)
2 001 ... 3 000 mm (78.78 ... 118.11 inch)2)
3 001 ... 4 000 mm (118.15 ... 157.48 inch)2)
4 001 ... 5 000 mm (173.26 ... 196.88 inch)2)
5 001 ... 5 500 mm (196.89 ... 216.54 inch)2)
Rod, 24 mm (0.94 inch), PFA insulated with 48 mm
(1.89 inch) stilling well in 316L stainless steel
Add Order code Y01 and Y02 and plain text:
"Insertion length ... mm and active shield
length ... mm"
250 ... 1 000 mm (9.84 ... 39.37 inch)
1 001 ... 2 000 mm (39.41 ... 78.74 inch)2)3)
2 001 ... 3 000 mm (78.78 ... 118.11 inch)2)3)
3 001 ... 4 000 mm (118.15 ... 157.48 inch)2)3)
4 001 ... 5 000 mm (173.26 ... 196.88 inch)2)3)
5 001 ... 5 500 mm (196.89 ... 216.54 inch)2)3)
Process connection (316L stainless steel)
Single piece flange, raised face
1½", ASME, 150 Ib
1½", ASME, 300 Ib
1½", ASME, 600 Ib
2", ASME, 150 Ib
2", ASME, 300 Ib
2", ASME, 600 Ib
3", ASME, 150 Ib2)
3", ASME, 300 Ib2)
3", ASME, 600 Ib2)
4", ASME, 150 Ib2)
4", ASME, 300 Ib2)
4", ASME, 600 Ib2)
6", ASME, 150 Ib2)
6", ASME, 300 Ib2)
6", ASME, 600 Ib2)
4/342
Siemens FI 01 · 2015
Article No.
7ML551777 7 77 - 7777
0A
1A
2A
3A
0B
1B
2B
3B
0C
1C
2C
3C
4C
5C
0D
1D
2D
3D
4D
5D
B1
B2
B3
C1
C2
C3
D1
D2
D3
E1
E2
E3
F1
F2
F3
Selection and Ordering data
SITRANS LC500, Single Piece Flanged with
Rod Sensor
Inverse frequency shift capacitance level and
interface transmitter for extreme and critical
process conditions, such as oil and liquid gas,
toxic and aggressive chemicals and vapours.
Single piece flange, Type B1 raised face
DN 40, PN 16
DN 40, PN 40
DN 50, PN 16
DN 50, PN 40
DN 80, PN 16
DN 80, PN 402)
DN 100, PN 162)
DN 100, PN 402)
DN 125, PN 162)
DN 125, PN 402)
Single piece flange with PTFE flange facing
(applicable with versions 0A ... 3A and 0C ... 5C)4)
1½" ASME, 150 Ib
1½", ASME, 300 Ib
1½", ASME, 600 Ib
2", ASME, 150 Ib
2", ASME, 300 Ib
2", ASME, 600 Ib
3", ASME, 150 Ib2)
3", ASME, 300 Ib2)
3", ASME, 600 Ib2)
4", ASME, 150 Ib2)
4", ASME, 300 Ib2)
4", ASME, 600 Ib2)
6", ASME, 150 Ib2)
6", ASME, 300 Ib2)
6", ASME, 600 Ib2)
Single piece flange with PTFE flange facing
(applicable with versions 0A ... 3A, 0C ... 5C)4)
DN 40, PN 16
DN 40, PN 40
DN 50, PN 16
DN 50, PN 40
DN 80, PN 16
DN 80, PN 402)
DN 100, PN 162)
DN 100, PN 402)
DN 125, PN 162)
DN 125, PN 402)
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5, or EN 1092-1 standard.)
Article No.
7ML5517777 77 - 7777
K4
K5
L4
L5
M4
M5
N4
N5
P4
P5
B4
B5
B6
C4
C5
C6
D4
D5
D6
E4
E5
E6
F4
F5
F6
K6
K7
L6
L7
M6
M7
N6
N7
P6
P7
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500
Selection and Ordering data
SITRANS LC500, Single Piece Flanged with
Rod Sensor
Inverse frequency shift capacitance level and
interface transmitter for extreme and critical
process conditions, such as oil and liquid gas,
toxic and aggressive chemicals and vapours.
Approvals
General Purpose: CE, CSA, FM, RCM
CSA / FM Class I, Div. 2, Groups A, B, C, D
CSA / FM Class II, III, Div. 1, Groups E, F, G T4
ATEX II 3G 2D EEx nA [ib] IIC T6 ... T4 T 100 °C
ATEX II 1/2 GD EEx d [ia] IIC T6 ... T1 T 100 °C
FM Class I, Div.1, Groups A, B, C, D, T4
Enclosure/Cable inlet
Aluminum epoxy coated
2 x ½" NPT, IP68
2 x M20 x1.5 (IP68, adapter)
Options
None
Slotted holes instead of standard vent holes in
stilling well (Refer to manual for dimensions)5)
Thermal isolator/remote version
Without thermal isolator
Isolator, only for use when temperature range is
outside of -40 ... +85 °C (-40 ... +185 °F),
explosion proof approval -40 ... +70 °C
(-40 ... +158 °F)
Remote electronics with mounting bracket and
cable6)
• Length: 2 m (79 inch)
• Length: 3 m (118 inch)
• Length: 4 m (158 inch)
• Length: 5 m (197 inch)
Electronic output
2-wire loop current 4 ... 20 mA
(transmitter MSP 2002-2 _3300 pF)
Article No.
7ML551777 7 77 - 7777
1
2
4
6
1
2
A
B
1)
A minimum span of 3 pF must be maintained
2)
Custom shipping methods required. Contact factory for more details.
3)
Available with process connection 2" or larger, and only available with
process connection options C1 ... F3, L4 ... P5
4)
Not available with versions 0E and 0F
5)
Available with version 0B ... 3B, 0D ... 5D and 0F only
6)
Available with approval option 1 only
Order code
Selection and Ordering data
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
Insertion length, specify in plain text: Y01: ... mm
Y01
Active shield length, specify in plain text
[min. length is 50 mm (2 inch)]: Y02: ... mm
Y02
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 27 characters) specify in plain text
Y15
Manufacturer's test certificate: M to DIN 55350,
Part 18 and to ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Manufacturing Test Report (Electrode Test)
C18
Operating Instructions
See page 4/345
Accessories
See page 4/345
A
B
C
D
E
F
1
Siemens FI 01 · 2015
4/343
4
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500
4
Selection and Ordering data
SITRANS LC500, Extended Cable version with
Rod Sensor, threaded connection or welded
flange1)
Inverse frequency shift capacitance level and
interface transmitter for short range continuous
measurement in large storage vessels.
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Version2)
Rod, 16 mm (0.63 inch), PFA insulated and 316L
stainless steel flexible extension tube
Total insertion length:
Add Order code Y01 and plain text: "Total insertion
length ... mm and Y02 and plain text:
Active shield length ... mm"3)4)
• 5 000 ... 10 000 mm (196.85 ... 393.70 inch)1)
• 10 001 ... 15 000 mm (393.74 ... 590.55 inch)1)
• 15 001 ... 20 000 mm (590.59 ... 787.40 inch)1)
• 20 001 ... 25 000 mm (787.44 ... 984.25 inch)1)
• 25 001 ... 30 000 mm (984.29 ... 1181.10 inch)1)
• 30 001 ... 35 000 mm (1 181.14 ... 1 377.95 inch)1)
Rod, 24 mm (0.94 inch), PFA insulated and 316L
stainless steel flexible extension tube
Total insertion length:
Add Order code Y01 and plain text: "Total insertion
length ... mm and Y02 and plain text:
Active shield length ... mm"3)4)
• 5 000 ... 10 000 mm (196.85 ... 393.70 inch)1)
• 10 001 ... 15 000 mm (393.74 ... 590.55 inch)1)
• 15 001 ... 20 000 mm (590.59 ... 787.40 inch)1)
• 20 001 ... 25 000 mm (787.44 ... 984.25 inch)1)
• 25 001 ... 30 000 mm (984.29 ... 1 181.10 inch)1)
• 30 001 ... 35 000 mm (1 181.14 ... 1 377.95 inch)1)
Process connection (316L stainless steel)
Threaded connection
2" NPT [(Taper), ANSI/ASME B1.20.1]
R 2" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
G 2" [(BSPP), EN ISO 228-1/PF (JIS-P) JIS B 0202]
Welded flange, raised face
2", ASME, 150 Ib
2", ASME, 300 Ib
3", ASME, 150 Ib1)
3", ASME, 300 Ib1)
4", ASME, 150 Ib1)
4", ASME, 300 Ib1)
6", ASME, 150 Ib1)
6", ASME, 300 Ib1)
Welded flange, Type A flat faced
DN 50, PN 16
DN 50, PN 40
DN 80, PN 16
DN 80, PN 401)
DN 100, PN 161)
DN 100, PN 401)
DN 125, PN 161)
DN 125, PN 401)
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5, or EN 1092-1 standard.)
Approvals
General Purpose: CE, CSA, FM, RCM
CSA / FM Class I, Div. 2, Groups A, B, C, D
CSA / FM Class II, III, Div. 1, Groups E, F, G T4
ATEX II 3G 2D EEx nA [ib] IIC T6 ... T4 T 100 °C
ATEX II 1/2 GD EEx d [ia] IIC T6 ... T1 T 100 °C
FM Class I, Div. 1, Groups A, B, C, D T4
4/344
Siemens FI 01 · 2015
Article No.
7ML55237 7 7 77 - 77 7 7
0A
1A
2A
3A
4A
5A
0B
1B
2B
3B
4B
5B
A0
B0
D0
C1
C2
D1
D2
E1
E2
F1
F2
L4
L5
M4
M5
N4
N5
P4
P5
1
2
4
6
Selection and Ordering data
SITRANS LC500, Extended Cable version with
Rod Sensor, threaded connection or welded
flange1)
Inverse frequency shift capacitance level and
interface transmitter for short range continuous
measurement in large storage vessels.
Enclosure/Cable inlet
Aluminum epoxy coated
2 x ½" NPT, IP68
2 x M20x1.5 (IP68, adapter)
Options
No additional options
With mounting eye
Thermal isolator
Without thermal isolator
Isolator, only for use when temperature range is
outside of -40 ... +85 °C (-40 ... +185 °F),
explosion proof approval -40 ... +70 °C
(-40 ... +158 °F)
Electronic output
2-wire loop current 4 ... 20 mA
(transmitter MSP 2002-2 _3300 pF)
Article No.
7ML55237 7 7 77 - 77 7 7
1
2
A
B
1)
Custom shipping methods required. Contact factory for more details.
2)
A minimum span of 3 pF must be maintained.
3)
See dimension drawings on page 4/354 for further explanation of Y01.
4)
Inactive length is equal to the flexible extension plus transition.
See dimension drawings on page 4/354 for further explanation of Y02.
A
B
1
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500
Selection and Ordering data
Order code
Order code
Selection and Ordering data
Further designs
Accessories
Please add "-Z" to Article No. and specify Order
code(s).
General Purpose
Y01
1/2" NPT General Purpose Cable Entry IP68/IP69K
NEMA6, -40 ... -100 °C (-40 ... -212 °F),
cable size 6 ... 12 mm (0.236 ... 0.472 inch)
7ML1830-1JA
Insertion length, specify in plain text: Y01: to mm
(Includes measuring range plus cable extension) see dimensional information on page 4/354
Y02
M20x1.5 General Purpose Cable Entry IP68/IP69K
NEMA6, -40 ... -100 °C (-40 ... -212 °F),
cable size 7 ... 12 mm (0.275 ... 0.472 inch)
7ML1830-1JC
Active shield/cable extension length, specify in
plain text [min. length is 50 mm (2 inch)]:
Y02: to mm (see dimensional information on
page 4/354)
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 27 characters) specify in plain text
Y15
Manufacturer's test certificate M to DIN 55350,
Part 18 and to ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Operating Instructions
Article No.
Hazardous Locations
1/2" NPT EMC rated Cable Gland: Dust Ignition Proof,
Flameproof Exd, and Increased Safety ATEX II 2 GD
ExtD A21 (Zone 1, Zone 2, Zone 21, Zone 22, and in
Gas Groups IIA,IIB and IIC) -60 ... +80 °C IP66, IP67,
IP68, NEMA4X, cable sizes 5.5 ... 12 mm
(0.216 ... 0.472 inch)
7ML1830-1JB
7ML1830-1JD
English
7ML1998-5GE04
French
7ML1998-5GE12
M20 EMC rated Cable Gland: Dust Ignition Proof,
Flameproof Exd, and Increased Safety ATEX II 2 GD
ExtD A21 (Zone 1, Zone 2, Zone 21, Zone 22 and in
Gas Groups IIA,IIB and IIC) -60 ... +80 °C IP66, IP67,
IP68, NEMA4X, cable sizes 5.5 ... 12 mm
(0.216 ... 0.472 inch)
Spanish
7ML1998-5GE21
Transmitter, MSP 2002-1, 330 PF1)
7ML1830-1JP
German
Note: The Operating Instructions should be
ordered as a separate line item on the order.
7ML1998-5GE33
Transmitter, MSP 2002-2, 3 300 PF1)
7ML1830-1JQ
Transmitter, MSP 2002-3, 6 600 PF (used with
conductive fluids and probe lengths >10 000 mm)1)
7ML1830-1JR
SITRANS RD100, loop powered display see Chapter 7
7ML5741-...
SITRANS RD200, universal input display with
Modbus conversion - see Chapter 7
7ML5740-...
SITRANS RD300, dual line display with totalizer
and linearization curve and Modbus conversion see Chapter 7
7ML5744-...
SITRANS RD500 web, universal remote monitoring
solution for instrumentation - see Chapter 7
7ML5750-...
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
For applicable back up point level switch see point level measurement section
1)
Transmitters not suitable for Intrinsically Safe application
(ATEX II 1G EEx ia IIC T4 or CSA/FM Class 1 Div. 1 Groups A, B, C and D
Please contact [email protected] for special requests.
Siemens FI 01 · 2015
4/345
4
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500
■ Characteristic curves
Pressure/temperature curve
LC500 cable probes
threaded process connections
(7ML5513)
Permitted operating pressures P
30 bar (435 psi)
20 bar (290 psi)
10 bar (145 psi)
Atmospheric
4
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
-29 ºC
(-20 ºF)
Example:
permitted operating pressure = 10 bar (145 psi) at 75 °C
SITRANS LC500 Process Pressure/Temperature derating curves (7ML5513)
4/346
Siemens FI 01 · 2015
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
Permitted operating temperature T
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500
Pressure/temperature curve
LC500 PFA rod probes
Threaded process connections
(7ML5515)
Permitted operating pressures P
150 bar (2.175 psi)
140 bar (2.030 psi)
130 bar (1.885 psi)
4
120 bar (1.740 psi)
110 bar (1.595 psi)
100 bar (1.450 psi)
90 bar (1.305 psi)
80 bar (1.160 psi)
70 bar (1.015 psi)
60 bar (870 psi)
50 bar (725 psi)
40 bar (580 psi)
30 bar (435 psi)
20 bar (290 psi)
Atmospheric
10 bar (145 psi)
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
-29 ºC
(-20 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
Permitted operating temperature T
SITRANS LC500 Process Pressure/Temperature derating curves (7ML5515)
Siemens FI 01 · 2015
4/347
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500
Pressure/temperature curve
LC500 cable probes
ASME flanged process connections
(7ML5513)
Permitted operating pressures P
20 bar (290 psi)
10 bar (145 psi)
ASME 150 lb1)
Atmospheric
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
4
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
-29 ºC
(-20 ºF)
1)
The curve denotes the minimum allowable flange class for the shaded area below.
SITRANS LC500 Process Pressure/Temperature derating curves (7ML5513)
4/348
Siemens FI 01 · 2015
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted operating temperature T
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500
Pressure/temperature curve
LC500 PFA rod probes
ASME flanged process connections
(7ML5515 and 7ML5517)
Permitted operating pressures P
150 bar (2.175 psi)
140 bar (2.030 psi)
130 bar (1.885 psi)
4
120 bar (1.740 psi)
110 bar (1.595 psi)
100 bar (1.450 psi)
90 bar (1.305 psi)
80 bar (1.160 psi)
70 bar (1.015 psi)
60 bar (870 psi)
ASME 600 lb1)
50 bar (725 psi)
40 bar (580 psi)
30 bar (435 psi)
ASME 300 lb1)
20 bar (290 psi)
Atmospheric
-40 ºF 14 ºF
(-40 ºC)(-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
ASME 150 lb1)
10 bar (145 psi)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
-29 ºC
(-20 ºF)
1)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted operating temperature T
The curve denotes the minimum allowable flange class for the shaded area below.
SITRANS LC500 Process Pressure/Temperature derating curves (7ML5515 and 7ML5517)
Siemens FI 01 · 2015
4/349
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500
Pressure/temperature curve
LC500 cable probes
EN flanged process connections
(7ML5513)
Permitted operating pressures P
20 bar (290 psi)
10 bar (145 psi)
PN 161)
Atmospheric
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
4
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
-29 ºC
(-20 ºF)
1)
The curve denotes the minimum allowable flange class for the shaded area below.
SITRANS LC500 Process Pressure/Temperature derating curves (7ML5513)
4/350
Siemens FI 01 · 2015
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted operating temperature T
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500
Pressure/temperature curve
LC500 PFA rod probes
EN flanged process connections
(7ML5515 and 7ML5517)
Permitted operating pressures P
150 bar (2.175 psi)
140 bar (2.030 psi)
130 bar (1.885 psi)
4
120 bar (1.740 psi)
110 bar (1.595 psi)
100 bar (1.450 psi)
90 bar (1.305 psi)
80 bar (1.160 psi)
70 bar (1.015 psi)
60 bar (870 psi)
50 bar (725 psi)
40 bar (580 psi)
30 bar (435 psi)
PN 401)
20 bar (290 psi)
Atmospheric
10 bar (145 psi)
-40 ºF 14 ºF
(-40 ºC)(-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
PN 161)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
-29 ºC
(-20 ºF)
1)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted operating temperature T
The curve denotes the minimum allowable flange class for the shaded area below.
SITRANS LC500 Process Pressure/Temperature derating curves (7ML5515 and 7ML5517)
Siemens FI 01 · 2015
4/351
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500
Pressure/temperature curve
LC500 single piece flanged rod probes with PTFE facing
EN flanged process connections
(7ML5517)
Permitted operating pressures P
80 bar (1.160 psi)
70 bar (1.015 psi)
60 bar (870 psi)
4
50 bar (725 psi)
40 bar (580 psi)
30 bar (435 psi)
PN 401)
20 bar (290 psi)
-40 ºF 14 ºF 100 ºF
(-40 ºC) (-10 ºC) (38 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
PN 161)
10 bar (145 psi)
Atmospheric
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
-29 ºC
(-20 ºF)
1)
The curve denotes the minimum allowable flange class for the shaded area below.
SITRANS LC500 Process Pressure/Temperature derating curves (7ML5517)
4/352
Siemens FI 01 · 2015
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted operating temperature T
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500
Pressure/temperature curve
LC500 single piece flanged rod probes with PTFE facing
ASME flanged process connections
(7ML5517)
Permitted operating pressures P
80 bar (1.160 psi)
70 bar (1.015 psi)
60 bar (870 psi)
ASME 600 lb1)
50 bar (725 psi)
40 bar (580 psi)
30 bar (435 psi)
ASME 300 lb1)
20 bar (290 psi)
Atmospheric
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
ASME 150 lb1)
10 bar (145 psi)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
-29 ºC
(-20 ºF)
1)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted operating temperature T
The curve denotes the minimum allowable flange class for the shaded area below.
SITRANS LC500 Process Pressure/Temperature derating curves (7ML5517)
Siemens FI 01 · 2015
4/353
4
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500
■ Dimensional drawings
Cable version, non-insulated
welded flange (7ML5513)
Cable version, insulated
welded flange (7ML5513)
Transmitter/
electronics
Option for mounting eye
only available for PFA
insulated cable
Stainless
steel weight
Ø12
(0.47)
Ø25 (0.98)
Ø12 (0.47)
Ø25 (0.98)
SITRANS LC500 - Cable Versions, dimensions in mm (inch)
Ø24
(0.94)
Ø35
(1.37)
15 (0.60)
Note:
1) Applicable for non-conductive media only.
Cable can be shortened on site. Weight is
included in measuring length.
2) Applicable for both liquids and solids.
Cable cannot be shortened. Weight is not
part of measuring length.
3) For Y02 lengths greater than 5 000 (197),
cable is inactive and is not actively
shielded.
4) Minimum length = 200 (7.87), maximum
length = 5 500 (216.54)
5) Insertion length Y01 =
Y02 + measuring length + 92 (3.62)
6) Insertion length Y01 =
Y02 + measuring length + 15 (0.59)
Mounting
eye option
Inactive tip
100 (3.9)
Mounting
eye
Ø48 (1.88)
Siemens FI 01 · 2015
Ø40
(1.57)
Measuring
Y02 Inactive length
length
Y01 (insertion length)
min. = 5 000 (197) / max. = 35 000 (1 378)
Mounting
eye option
54 (2.12)
Stainless
steel
flexible
tube
20
(0.79)
Y02 Inactive length
Y01 (insertion length)
min. = 5 000 (197) / max. = 35 000 (1 378)
Measuring
length
63
92
(3.62) (2.48)
20 (0.79)
4/354
Mounting
eye
Extended cable version with rod sensor
welded flange (7ML5523)
Extended cable version with rod sensor
welded flange (7ML5523)
Ø16
(0.63)
Ø34.5 (1.36)
Ø34.5 (1.36)
Ø32 (1.26)
Stainless
steel
flexible
tube
350 (13.78)
Ø9 (0.35)
Ø9 (0.35)
20 (0.79)
Measuring
length
Y01 (insertion length)
min. = 1 000 (39.40) / max. = 35 000 (1 378)
Stainless
steel weight
PFA insulated
probe
350 (13.78)
Masuring length
250 (9.84)
Ø6 (0.24)
92
(3.62)
4
Stainless
steel cable
Y01 (insertion length)
min. = 1 000 (39.40) / max. = 35 000 (1 378)
20 (0.79)
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500
Cable version, non-insulated 1)
Welded flange (7ML5513)
Cable version, insulated 2)
Welded flange (7ML5513)
Transmitter/
electronics
Option for mounting eye
only available for PFA
insulated cable
350 (13.78)
Ø12
(0.47)
Ø25 (0.98)
20
(0.79)
Mounting
eye option
Ø40
(1.57)
Mounting
eye
Ø12 (0.47)
Ø25 (0.98)
Ø48 (1.88)
Ø24
(0.94)
Ø35
(1.37)
Note:
1) Applicable for non-conductive media only.
Cable can be shortened on site. Weight is
included in measuring length.
2) Applicable for both liquids and solids.
Cable cannot be shortened. Weight is not
part of measuring length.
3) For Y02 lengths greater than 5 000 (197),
cable is inactive and is not actively
shielded.
4) Minimum length = 200 (7.87), maximum
length = 5 500 (216.54)
5) Insertion length Y01 =
Y02 + measuring length + 92 (3.62)
6) Insertion length Y01 =
Y02 + measuring length + 15 (0.59)
Mounting
eye option
Inactive tip
100 (3.9)
Stainless
steel
flexible
tube
Measuring
Y02 Inactive length
length 4)
6)
Y01 (insertion length)
min. = 5 000 (197) / max. = 35 000 (1 378)
Y01 (insertion length)
min. = 5 000 (197) / max. = 35 000 (1 378)
Mounting
eye
Extended cable version with rod sensor 3)
Welded flange (7ML5523)
5)
Y02 Inactive length
63
92
(3.62) (2.48)
Measuring
length 4)
92
(3.62)
4
Ø34.5 (1.36)
Extended cable version with rod sensor 3)
Welded flange (7ML5523)
Ø16
(0.63)
Ø34.5 (1.36)
20 (0.79)
Stainless steel
weight, actual
weight = (2.15 kg
[4.75 lb])
Ø32 (1.26)
Stainless
steel
flexible
tube
Y01 (insertion length)
max. = 35 000 (1 378)
Measuring
length
350 (13.78)
Stainless steel
weight, actual
weight = (1.27 kg
[2.80 lb])
Ø9 (0.35)
54 (2.12)
250 (9.84)
Ø6 (0.24)
PFA insulated
probe
Y01 (insertion length)
max. = 35 000 (1 378)
Measuring length
Stainless
steel cable
Ø9 (0.35)
15 (0.60)
SITRANS LC500 - Cable Versions, dimensions in mm (inch)
Siemens FI 01 · 2015
4/355
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500
Rod version with stilling well
threaded (7ML5515)
Stainless
steel stilling
well
Measuring length1)
Vent holes or
optional slots
PFA insulated
probe
*
Ø16 (0.63)
or Ø24 (0.94)
150 (6)
205 (8.1)
Y01 (insertion length)
min. = 200 (7.87) / max. = 3 500 (138), Ø16 (0.63)
min. = 200 (7.87) / max. = 5 500 (216), Ø24 (0.94)
Ø16 (0.63)
or Ø24 (0.94)
Y02 1)
205 (8.1)
Y01 (insertion length)
min. = 200 (7.87) / max. = 3 500 (138), Ø16 (0.63)
min. = 200 (7.87) / max. = 5 500 (216), Ø24 (0.94)
Measuring length
PFA insulated
probe
*
Stainless steel flexible tube
General purpose approval only.
Standard configuration
(all versions)
M20: 160 (6.3)
1/2" NPT: 230 (9.1)
With thermal isolator
option (all versions)
Ø35 (1.38)
or Ø48 (1.89)
* = 30 (1.18) inactive tip
Note:
1) Minimum Y02 (active shield length) = 50 (1.96),
minimum measuring length = 200 (7.87)
430 (16.9)
With explosion-proof
seal option
(all versions)
270 (10.6)
4
1)
20
(0.79)
Y02 1)
Transmitter/
electronics
Remote electronics with mounting bracket option
threaded (7ML5515)
205 (8.1)
Rod version
threaded (7ML5515)
Thermal
isolator
SITRANS LC500 - Rod Versions, dimensions in mm (inch)
4/356
Siemens FI 01 · 2015
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500
Rod version
Welded flange (7ML5515)
Single piece flange (7ML5517)
Rod version with stilling well
Welded flange (7ML5515)
Single piece flange (7ML5517)
150 (6)
Y02 1)
Measuring length1)
Vent holes or
optional slots
PFA insulated
probe
Ø16 (0.63)
or Ø24 (0.94)
Ø35 (1.38)
or Ø48 (1.89)
Ø16 (0.63)
or Ø24 (0.94)
General purpose approval only.
2)
Stainless steel
stilling well
Y01 (insertion length)
min. = 200 (7.87) / max. = 3 500 (138), Ø16 (0.63)
min. = 200 (7.87) / max. = 5 500 (216), Ø24 (0.94)
*
PFA insulated
probe
Stainless steel flexible tube
*
Y02 1)
Measuring length1)
2)
Y01 (insertion length)
min. = 200 (7.87) / max. = 3 500 (138), Ø16 (0.63)
min. = 200 (7.87) / max. = 5 500 (216), Ø24 (0.94)
205 (8.1)
(Typical)
Transmitter/
electronics
Remote electronics with mounting bracket option
Welded flange (7ML5515)
Single piece flange (7ML5517)
PTFE flange facing option
single piece flange only (7ML5517)
Raised
face flange
4
PTFE flange
facing
No stilling well or enamel probe available with this
option.
* = 30 (1.18) inactive tip
Flange facing (raised face)
205 (8.1)
Standard configuration
(all versions)
Flange class
M20: 160 (6.3)
1/2" NPT: 230 (9.1)
Facing thickness
ASME 150/300
2 (0.08)
ASME 600/900
7 (0.28)
PN16/25/40/64
2 (0.08)
PTFE facing (additional)
2 (0.08)
With thermal isolator
option (all versions)
Notes:
1) Minimum Y02 (active shield length) = 50 (1.96),
minimum measuring length = 200 (7.87)
2) Insertion length does not include any raised face/gasket face
dimension (see Flange Facing table above).
270 (10.6)
430 (16.9)
With explosion-proof
seal option (all
versions)
Thermal
isolator
SITRANS LC500 - Rod Versions, dimensions in mm (inch)
Siemens FI 01 · 2015
4/357
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500
■ Schematics
Ground lug
Protective
label
Solid state
switch relay
(any polarity)
Instrument
system
ground
4
Measuring
signal
(minicoaxial
cable)
Type:
Ser.:
Date:
Rev.:
Tampering voids warranty
Ground connection
point for instrument
system
SITRANS LC500 connections
4/358
Siemens FI 01 · 2015
4 ... 20 mA
current loop
connection
(any polarity)
© Siemens AG 2014
Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC300 and LC500 Specials
■ Selection and ordering data
LC300 and LC500 Specials1)
LC300 and LC500 Specials1)
Article No.
LC300 Cable Extensions,
316L stainless steel
Article No.
LC300 Mounting Eye
Spare mounting eye (LC300 PFA versions only)
A5E01163717
LC300 Weight Kit, 316L stainless steel
Kit, stainless steel cable extension, 1 m,
adjustable by customer
A5E01163688
Kit, stainless steel cable extension, 3 m,
adjustable by customer
A5E01163689
Kit, stainless steel cable extension, 5 m,
adjustable by customer
A5E01163690
Kit, stainless steel cable extension, 10 m,
adjustable by customer
A5E01163691
Kit, Spare stainless steel weight. To be used in
any cable version of CLS300, or stainless steel
cable version of LC300
Kit, stainless steel cable extension, 15 m,
adjustable by customer
A5E01163693
LC500 Gasket (IP65), Silicone
Kit, stainless steel cable extension, 20 m,
adjustable by customer
A5E01163695
A5E01163727
LC300 Cable Extensions,
316 stainless steel with PFA coating
Spare gasket, LC500 enclosure version, IP65
A5E01163728
LC500 Blind Lid
A5E01163709
Spare LC500 aluminum blind lid
Kit, PFA cable extension, 3 m
A5E01163710
LC500 Mounting Eye
Kit, PFA cable extension, 5 m
A5E01163711
Kit, PFA cable extension, 10 m
A5E01163712
Kit, PFA cable extension, 15 m
A5E01163713
Kit, PFA cable extension, 20 m
A5E01163714
Kit, PFA cable extension, 1 m
A5E01163729
Spare mounting eye (PFA cable version only)
A5E01163717
LC500 Mounting Bracket
Spare mounting bracket
A5E01163730
LC500 Sanitary Versions2)
1)
Special flange sizes and facings are available. Please contact
[email protected] for part number and pricing.
Submit Application Questionnaire found on page 4/11.
2)
Please contact [email protected] for part number and pricing.
Submit Application Questionnaire found on page 4/11.
Please contact [email protected] for special requests.
Siemens FI 01 · 2015
4/359
4
© Siemens AG 2014
Level Measurement
Communication
SmartLinx module
■ Overview
■ Technical specifications
4
SmartLinx modules provide direct digital connection to popular
industrial communications buses with true plug-and-play
compatibility with products manufactured by Siemens.
Module type
PROFIBUS DP
• Interface
RS 485 (PROFIBUS standard)
• Transmission rate
All valid PROFIBUS DP rates from
9 600 Kbps to 12 Mbps
• Rack address
0 ... 99
• Connection
Slave
• SmartLinx module compatibility
• MultiRanger 100/200
• HydroRanger 200
Module type
DeviceNet
• Interface
DeviceNet physical layer
• Transmission rate in kbps
125, 250, 500
• Rack address
0 ... 63
• Connection
Slave (group 2)
• SmartLinx module compatibility
• MultiRanger 100/200
• HydroRanger 200
Selection and Ordering data
■ Benefits
• Fast, easy installation
• Direct connection: no additional installation required
• Scaleable application layer allows for optimized network
bandwidth and memory requirements
• Modules available for PROFIBUS DP and DeviceNet
■ Application
Many Siemens products include HART, PROFIBUS PA and
Modbus communications. For additional communication
modules, SmartLinx cards are the answer.
They’re fast and easy to install, and can be added at any time.
The module simply plugs into the socket on any SmartLinxenabled product. They require no secondary private buses or
gateways and no separate wiring. There are no extra boxes to
connect to your network so there’s a minimum load on
engineering and maintenance staff.
SmartLinx provides all data from the instrument, including
measurement and status, and allows changes to operation
parameters to be done over the bus or telemetry link. The user
can select which data in the application layer to transfer over the
bus. This selection saves bandwidth and memory and optimizes
data throughput and speeds up the network, enabling you to
connect more instruments to your network.
4/360
Article No.
SmartLinx module for MultiRanger 100/200 and
HydroRanger 200
Siemens FI 01 · 2015
PROFIBUS DP module
7ML1830-1HR
DeviceNet module
7ML1830-1HT
Operating Instructions
PROFIBUS communications module
• English
7ML1998-1AQ03
• French
7ML1998-1AQ13
• German
7ML1998-1AQ33
DeviceNet
This device is shipped with the Siemens Milltronics
manual DVD containing Quick Starts and Operating Instructions.
7ML1998-1BH02
• English
7ML1998-1BH02
• French
7ML1998-1BH12
Spare SmartLinx software
PROFIBUS DP data diskette
7ML1830-1CL
DeviceNet data diskette
7ML1830-1CM
© Siemens AG 2014
Level Measurement
Communication
Dolphin Plus Software
■ Overview
Compatibility
Dolphin Plus is compatible with Microsoft Windows
95/98/NT4/Me/2000/XP and works with a wide range of Siemens
products, including:
• SITRANS LU10
• SITRANS LU02
• SITRANS LU01
Connection to a Siemens instrument may be a direct RS 232
serial connection or via an RS 485 converter or Siemens infrared
ComVerter, depending on the instrument being configured.
Meets VDE 2187 user interface requirements.
(Most other Siemens level devices use Simatic PDM
configuration software.)
Dolphin Plus is instrument configuration software that allows you
to quickly and easily configure, monitor, tune and diagnose
several Siemens level devices remotely (see list below).
Remote access is available using your desktop PC or connected
directly in the field using a laptop.
■ Benefits
• Real-time monitoring and adjustment of parameters
• On-screen visualization of process values
• Saving and visualization of echo profiles for a wide range of
Siemens level meters
• Copying of data for programming several devices
• Quick setup and commissioning of device
• Generation of configuration reports within seconds
Note:
The Dolphin Plus software is only available in English.
■ Application
Dolphin Plus is easy to install and use. Just load the software
from the DVD. In minutes, you’re ready to set up or modify
complete parameter configurations for one or more devices.
Following configuration, you can alter parameters, upload and
download parameter sets to and from disk, and use parameter
sets saved from other instruments. Reading of echo profiles
permits fine tuning without the need for special instruments.
Built-in quick start wizards and help functions guide you through
the entire process.
Selection and Ordering data
Article No.
Dolphin Plus
Instrument configuration software to quickly and
easily configure, monitor, tune and diagnose most
Siemens devices remotely, from your desktop PC or
connected directly in the field using a laptop.
Dolphin Plus Software includes a software DVD,
and a nine pin adapter with a 2.1 m (82.7 inch)
cable for connection to a PC serial port.
7ML18417AA 0 7
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
RS 485 to RS 232 converter
No
Yes
0
1
ComVerter
No
Yes
0
1
Article No.
Selection and Ordering data
Operating Instructions
Connection manual, English:
Included on Dolphin Plus DVD and available at
www.siemens.com/processautomation
Spare parts
Converter, RS 485 to RS 232 (D-Sub)
7ML1830-1HA
Kit containing one 9-pin D-Sub to RJ11 Adapter
and one 2.1 meter telephone cable with two male
jacks
7ML1830-1MC
ComVerter, Infrared link
7ML1830-1MM
Siemens FI 01 · 2015
4/361
4
© Siemens AG 2014
Level Measurement
Notes
4
4/362
Siemens FI 01 · 2015
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement