使用手冊SPH , SS , SSC , SSN-HQ - Tough Guy

Add to my manuals
2 Pages

advertisement

使用手冊SPH , SS , SSC , SSN-HQ - Tough Guy | Manualzz
6. Do not allow the cord to interfere with the float control motion
or to drape over the pump motor. With electrician's tape, secure
the cords to the discharge pipe. This will provide protection
for the cords and make a neat installation.
7. Plug switch into grounded outlet and plug pump into switch
plug. Restore electrical power at the service entrance. Fill
sump pit with water to check automatic switch operation.
Limited Warranty:
CONDITION
COMMON CAUSES
Check fuse, low voltage, overload open, open
or incorrect wiring, open switch, impeller or
A. Pump will not
start or run.
seal bound mechanically, defective capacitor
or relay when used, motor or wiring shorted.
Float assembly held down. Switch defective,
damaged, or out of adjustment.
8. Install a sump cover. A cover will prevent solid matter from
falling into the sump, prevent odor, and guards against
accidental injury.
B. Motor overheats
and trips overload
or blows fuse.
Incorrect voltage, negative head (discharge
open lower than normal) impeller or seal bound
mechanically, defective capacitor or relay,
motor shorted.
SERVICE CHECKLIST
Float tight on rod, check valve stuck or none
C. Pump starts and
installed in long distance line, overload open,
stops too often.
level switch(s) defective, sump pit too small.
WARNING
ELECTRICAL PRECAUTIONS
Before servicing a pump, always shut off the main power
breaker and then unplug the pump - making sure you are
wearing insulated protective sole shoes and not standing in
water. Under flooded conditions, contact your local electric
company or a qualified licensed electrician for disconnecting
electrical service prior to pump removal.
D. Pump will not
shut off.
bound by pit sides or other, switch defective,
Check strainer housing, discharge pipe, or if
Submersible pumps contain oils which becomes pressurized
and hot under operating conditions - allow 2½ hours after
disconnecting before attempting service.
This warranty is subject to due compliance by the original purchaser with all
directions and conditions set out in the installation and operating instructions.
Failure to comply with these instructions, damage or breakdown caused by
fair wear and tear, negligence, misuse, incorrect installation, inappropriate
chemicals or additives in the water, inadequate protection against freezing, rain
or other adverse weather conditions, corrosive or abrasive water, lightning or
high voltage spikes or through unauthorized persons attempting repairs are
not covered under warranty.
Tough Guy will not be liable for any incidental or consequential damages,
losses, or expenses, arising from installation, use, or any other causes. There
are no express or implied warranties, including merchantability or fitness for
a particular purpose, which extend beyond those warranties described or
referred to above.
check valve is used vent hole must be clear.
Discharge head exceeds pump capacity. Low
or incorrect voltage. Incorrect motor rotation.
Capacitor defective. Incoming water containing
WARNING
The warranty period commences on the date of original purchase of the
equipment. Proof of purchase and installation date, failure date, and supporting
installation data must be provided when claiming repairs under warranty.
Debris under float assembly, float or float rod
damaged or out of adjustment.
E. Pump operates
but delivers little
or no water.
Products of Tough Guy Fluid Technology (Tough Guy) are warranted to the first
user only to be free of defects in material and workmanship for a period of 12
months from date of installation, but no more than 24 months from date of
shipment. Tough Guy's liability under this warranty shall be limited to repairing
or replacing at our election, without charge, FOB Tough Guy's distribution
center or authorized service agent. Tough Guy will not be liable for any cost of
removal, installation, transportation or any other charges that may arise in
connection with warranty claim.
air or causing air to enter pumping chamber.
Increased pipe friction, clogged line or check
F. Drop in head and
/or capacity after a valve. Abrasive material and adverse chemicals
could possibly deteriorate impeller and pump
period of use.
Certain countries do not permit the exclusion or limitation of incidental or
consequential damages or the placing of limitations on the duration of an
implied warranty, therefore, the limitations or exclusions herein may not apply.
This warranty sets forth specific legal rights and obligations, however,
additional rights may exist, which may vary from countries to countries
Supersedes all previous publications
FLUID TECHNOLOGY
housing. Check line. Remove base and inspect.
R
WEBSITE : www.toughguyfluidtech.com
E-MAIL : [email protected]
R
FLUID TECHNOLOGY
Installation and Operating Instructions
SPH , SS , SSC , SSN
PREINSTALLATION CHECKLIST - ALL INSTALLATIONS
1. Inspect your pump. Occasionally, products are damaged
during shipment. If the unit is damaged, contact your dealer
before using. Do Not remove the test plug in the cover.
2. Carefully read the literature provided to familiarize yourself
with specific details regarding installation and use. These
materials should be retained for future reference.
WARNING
SEE BELOW FOR LIST OF WARNINGS
1. Make sure there is a properly installed ground fault circuit
interrupter (GFCI) protected circuit available. All pumps are
furnished with provisions for proper grounding to help protect
you against the possibility of electrical shock.
2. Make certain that the ground fault receptacle is within the reach
of pump’s power supply cord. DO NOT USE AN EXTENSION
CORD. Extension cords that are too long or too light do not
deliver sufficient voltage to the pump motor. More importantly,
they could present a safety hazard if the insulation were to
become damaged or the connection ends were to fall into the
sump and become wet.
3. Make sure the pump electrical supply circuit is equipped with
fuses or circuit breakers of proper capacity. A separate branch
circuit is recommended, sized according local codes for the
current shown on the pump name plate.
4. TESTING FOR GROUND. As a safety measure, each electrical
outlet should be checked for ground using a recognized circuit
analyzer which will indicate if the power, neutral and ground
wires are correctly connected to your outlet. If they are not, call
a qualified licensed electrician.
5. Installation and checking of electrical circuits and hardware
should only be performed by a qualified licensed electrician.
6. FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP
FROM ITS POWER SOURCE BEFORE HANDLING.
7. Risk of electric shock. This pump has not been investigated
for use in swimming pool areas.
8. For Added Safety. Use of a residual current device with an
operating current no higher than 30 mA is recommended.
9. If the supply cable is damaged, it must be replaced by the
manufacturer, or its technical service, or similarly qualified
persons in order to avoid a hazard.
10. The appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they have been given
supervision or instruction to concerning use of the appliance
by a person responsible for their safety.
11. Pump is not intended for potable water due to possible
contamination by oil contained in the pump.
CAUTION
SEE BELOW FOR LIST OF CAUTIONS
3. Information - vent hole purpose. It is necessary that all
submersible sump and sewage pumps capable of handling
various sizes of solid waste be of the bottom intake design to
reduce clogging and seal failures. If a check valve is incorporated
in the installation, a vent hole (approx. 5 mm) must be drilled in
the discharge pipe below the check valve and pit cover to purge
the unit of trapped air. Trapped air is caused by agitation and/
or a dry basin. Vent hole should be checked periodically for
clogging. You may not want to drill one. If you choose not to
drill a vent hole, be sure the pump case and impeller is covered
with liquid before connecting the pipe to the check valve and no
inlet carries air to the pump intake. NOTE: THE HOLE MUST
ALSO BE BELOW THE BASIN COVER AND CLEANED
PERIODICALLY. Water stream will be visible from this hole
during pump run periods.
4. Pump should be checked frequently for debris and/or build up
which may interfere with the float “on” or “off ” position.
5. Dewatering and sump pumps (SPH Series) are not designed
for use in pits handling raw sewage.
1. Check to be sure your power source is capable of handling the
voltage requirements of the motor, as indicated on the pump
name plate.
6. Maximum operating temperature for standard model pumps
must not exceed 104°F (40°C).
2. The installation of automatic pumps with variable level float
switches or non-automatic pumps using auxiliary variable level
float switches is the responsibility of the installing party. Care
should be taken that the tethered float switch will not hang up
on the pump apparatus or pit peculiarities and is secured so
that the pump will shut off. It is recommended to use rigid piping
and fittings and the pit be 18" or larger in diameter.
8. Pump not intended for continuous run application, misapplication
may reduce pump life.
7. Do not operate a pump in an application where the Total
Dynamic Head is less than the minimum Total Dynamic Head
listed on the Pump Performance Curves.
DO NOT USE FOR PUMPING OILS, GASOLINE
OR ANY PETROLEUM BY-PRODUCTS.
GENERAL INFORMATION
1. Automatic models are equipped with an omnidirectional
mechanical float switch. The pump will turn on automatically
when the water level in the sump reaches approximately the
float switch "on" level and automatically turn off when the water
is pumped down to the float switch "off " level.
2. The sump pit must be a minimum of 22" deep and 12" in
diameter. The pump requires a minimum diameter of 12" so
that the float switch will operate without restriction. Any
smaller diameter may restrict the switch operation, resulting
in pump failure.
INSTALLATION
1. For your safety, turn off the electrical power at the service
entrance to avoid any possible electrical shock hazards.
2. On a replacement installation, remove the existing pump from
the sump by disconnecting the discharge pipe or hose from the
old pump. Depending on how your old pump is installed, unscrew
clamps and discard old corrugated hose, or unscrew galvanized
or plastic pipe from pump discharge. If discharge pipe cannot
be removed easily, saw through the pipe about five feet above
the pump discharge.
3. After removing the old pump, remove sediment, debris, and
any standing water from the sump pit.
4. Place your pump in the sump and attach the discharge piping.
Be sure that the pump is positioned so that the float switch
moves freely without touching the wall of the sump or other
obstructions.
5. Install a full flow check valve to prevent back flow which can
cause the pump to cycle too frequently and result in wear and
shortened motor life. Drill 3/16" vent hole in piping below the
pit cover and check valve. Water stream will be visible from
this hole during pump run periods. Reattach discharge piping
as required.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement