HP Virtual Connect for c-Class BladeSystem - Hewlett Packard

HP Virtual Connect for c-Class BladeSystem - Hewlett Packard
HP Virtual Connect for c-Class BladeSystem
Setup and Installation Guide
Version 4.30/4.31
Abstract
This document contains setup, installation, and configuration information for HP Virtual Connect. This document is for the person who installs,
administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the servicing of computer equipment and trained in
recognizing hazards in products with hazardous energy levels.
Part Number: 762311-003
November 2014
Edition: 3
В© Copyright 2014 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express
warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall
not be liable for technical or editorial errors or omissions contained herein.
MicrosoftВ®, WindowsВ®, and Windows ServerВ® are U.S. registered trademarks of the Microsoft group of companies.
AdobeВ® is a registered trademark of Adobe Systems Incorporated.
Contents
Documentation resources ............................................................................................................... 6
Virtual Connect documentation.................................................................................................................... 6
Planning the installation ................................................................................................................. 8
Virtual Connect overview............................................................................................................................ 8
VC module supported firmware ......................................................................................................... 9
Using multiple enclosures .................................................................................................................. 9
Pre-deployment planning .......................................................................................................................... 10
Hardware setup overview ......................................................................................................................... 12
Default module configuration .......................................................................................................... 13
Virtual Connect Manager setup overview ................................................................................................... 13
Installation ................................................................................................................................. 15
Installation requirements ........................................................................................................................... 15
Supported configurations ................................................................................................................ 16
Bay configuration requirements ....................................................................................................... 19
HP Virtual Connect Flex-10 Module requirements ............................................................................... 20
HP Virtual Connect Flex-10/10D Module requirements ....................................................................... 21
HP Virtual Connect FlexFabric 10Gb/24-port Module requirements ..................................................... 21
HP Virtual Connect FlexFabric-20/40 F8 Module requirements ............................................................ 22
Virtual Connect and EBIPA .............................................................................................................. 22
Stacking Links ......................................................................................................................................... 23
Recommended stacking connections ................................................................................................ 24
Configuring partially stacked domains ............................................................................................. 27
Network loop protection ................................................................................................................. 28
Connecting multiple enclosures ................................................................................................................. 29
Multiple enclosure requirements ....................................................................................................... 31
FC and FlexFabric bay configuration using multiple enclosures ............................................................ 32
Directly connecting VC domains ................................................................................................................ 34
Virtual Connect FIPS mode of operation ..................................................................................................... 34
FIPS mode information and guidelines .............................................................................................. 34
Enabling FIPS mode ....................................................................................................................... 35
FIPS mode indicators (domain) ........................................................................................................ 36
FIPS mode indicators (VC Ethernet modules) ...................................................................................... 36
Installing a VC-Enet module ...................................................................................................................... 36
Installing a VC FlexFabric module.............................................................................................................. 39
Installing a VC-FC module ........................................................................................................................ 41
Installing DAC/AOC cables and transceivers .............................................................................................. 43
Installing the cable ......................................................................................................................... 43
Installing the transceiver ................................................................................................................. 44
Removing QSFP+, SFP+ or SFP transceivers ................................................................................................ 46
Factory default settings ............................................................................................................................. 46
Connecting Virtual Connect Ethernet module uplinks .................................................................................... 47
Configuration example using a Cisco Core switch ............................................................................. 50
Failover and check-pointing ...................................................................................................................... 52
Interconnect module removal and replacement ............................................................................................ 52
Virtual Connect modules ................................................................................................................. 52
Contents
3
Upgrading to an HP Virtual Connect 8Gb 24-Port FC Module ............................................................. 53
Upgrading to an HP Virtual Connect 8Gb 20-Port FC Module ............................................................. 53
Upgrading or removing an HP Virtual Connect Flex-10, HP Virtual Connect FlexFabric, or HP Virtual Connect
Flex-10/10D module ..................................................................................................................... 54
Upgrading to an HP Virtual Connect FlexFabric module from a VC-FC module ...................................... 56
Onboard Administrator modules ...................................................................................................... 57
HP Virtual Connect Manager........................................................................................................ 58
Configuring browser support .................................................................................................................... 58
Virtual Connect and Insight Control Server Deployment ................................................................................ 59
Accessing HP Virtual Connect Manager ..................................................................................................... 60
Command Line Interface overview ................................................................................................... 60
Logging on to the HP Virtual Connect Manager GUI .................................................................................... 61
About HP Virtual Connect Manager ........................................................................................................... 62
Reset Virtual Connect Manager ................................................................................................................. 62
Recovering remote enclosures ......................................................................................................... 62
Running the setup wizards ........................................................................................................................ 63
HP Virtual Connect Domain Setup Wizard ........................................................................................ 63
HP Virtual Connect Network Setup Wizard ....................................................................................... 73
HP Virtual Connect Fibre Channel Setup Wizard ............................................................................... 88
HP Virtual Connect Manager Server Profile Setup Wizard .................................................................. 94
Verifying data center connections ............................................................................................................ 102
Verify link and speed ................................................................................................................... 103
Verify network status using VC Manager ........................................................................................ 103
Component identification ........................................................................................................... 104
HP Virtual Connect Flex-10 10Gb Ethernet Module components and LEDs .................................................... 104
HP Virtual Connect Flex-10 10Gb Ethernet Module components ........................................................ 104
HP Virtual Connect Flex-10 10Gb Ethernet Module LEDs .................................................................. 105
HP Virtual Connect Flex-10 10Gb Ethernet Module system maintenance switch ................................... 107
HP Virtual Connect Flex-10/10D Module components and LEDs .................................................................. 108
HP Virtual Connect Flex10/10D Module components....................................................................... 108
HP Virtual Connect Flex10/10D Module LEDs ................................................................................. 108
HP Virtual Connect Flex10/10D Module system maintenance switch .................................................. 110
HP Virtual Connect FlexFabric-20/40 F8 Module components and LEDs ....................................................... 111
HP Virtual Connect FlexFabric-20/40 F8 Module components ........................................................... 111
HP Virtual Connect FlexFabric-20/40 F8 Module LEDs ..................................................................... 112
HP Virtual Connect FlexFabric-20/40 F8 Module system maintenance switch ...................................... 115
HP Virtual Connect FlexFabric 10Gb/24-port Module components and LEDs ................................................ 116
HP Virtual Connect FlexFabric 10Gb/24-port Module components .................................................... 116
HP Virtual Connect FlexFabric 10Gb/24-port Module LEDs .............................................................. 116
HP Virtual Connect FlexFabric 10Gb/24-port Module system maintenance switch ............................... 119
HP Virtual Connect 4Gb FC Module (with enhanced NPIV) components and LEDs ......................................... 120
HP Virtual Connect 4Gb FC Module components ............................................................................. 120
HP Virtual Connect 4Gb FC Module LEDs ....................................................................................... 121
HP Virtual Connect 4Gb FC Module system maintenance switch ........................................................ 122
HP Virtual Connect 8Gb 24-Port Fibre Channel Module components and LEDs .............................................. 123
HP VC 8Gb 24-Port FC Module components ................................................................................... 123
HP VC 8Gb 24-Port FC Module LEDs ............................................................................................. 124
HP VC 8Gb 24-Port FC Module system maintenance switch .............................................................. 125
HP Virtual Connect 8Gb 20-Port Fibre Channel Module components and LEDs .............................................. 126
HP VC 8Gb 20-Port FC Module components ................................................................................... 126
HP VC 8Gb 20-Port FC Module LEDs ............................................................................................. 126
HP VC 8Gb 20-Port FC Module system maintenance switch .............................................................. 127
Contents
4
Resetting the Administrator password and DNS settings.............................................................................. 128
Regulatory information .............................................................................................................. 130
Safety and regulatory compliance ........................................................................................................... 130
Belarus Kazakhstan Russia marking ......................................................................................................... 130
Turkey RoHS material content declaration ................................................................................................. 131
Ukraine RoHS material content declaration ............................................................................................... 131
Warranty information ............................................................................................................................ 131
Electrostatic discharge ............................................................................................................... 132
Preventing electrostatic discharge ............................................................................................................ 132
Grounding methods to prevent electrostatic discharge ................................................................................ 132
Support and other resources ...................................................................................................... 133
Before you contact HP............................................................................................................................ 133
HP contact information ........................................................................................................................... 133
Customer Self Repair ............................................................................................................................. 133
Acronyms and abbreviations ...................................................................................................... 141
Documentation feedback ........................................................................................................... 144
Index ....................................................................................................................................... 145
Contents
5
Documentation resources
Virtual Connect documentation
The following Virtual Connect documentation is available on the HP website
(http://www.hp.com/go/vc/manuals):
•
HP Virtual Connect for c-Class BladeSystem User Guide
This guide provides details for the Virtual Connect GUI, including descriptions of screen contents and
steps to set up domains, profiles, networks, and storage.
•
HP Virtual Connect for c-Class BladeSystem Setup and Installation Guide
This guide provides hardware installation and configuration information for initial setup of a Virtual
Connect solution. The guide also provides Virtual Connect module component and LED descriptions
and guidelines for module installation and upgrades.
•
HP Virtual Connect Manager Command Line Interface for c-Class BladeSystem User Guide
This guide provides information for using the Virtual Connect Command Line Interface, including use
scenarios and complete descriptions of all subcommands and managed elements.
•
HP Virtual Connect Ethernet Cookbook: Single and Multiple Domain (Stacked) Scenarios
This guide helps new Virtual Connect users understand the concepts of and implement steps for
integrating Virtual Connect into a network. The scenarios in this guide vary from simplistic to more
complex while covering a range of typical building blocks to use when designing Virtual Connect
solutions.
•
HP Virtual Connect Fibre Channel Networking Scenarios Cookbook
This guide details the concepts and implementation steps for integrating HP BladeSystem Virtual
Connect Fibre Channel components into an existing SAN fabric. The scenarios in this guide are
simplistic while covering a range of typical building blocks to use when designing a solution.
•
HP Virtual Connect with iSCSI Cookbook
This guide describes how to configure HP Virtual Connect for an iSCSI environment. It provides tips and
troubleshooting information for iSCSI boot and installation.
•
HP Virtual Connect FlexFabric Cookbook
This guide provides users with an understanding of the concepts and steps required when integrating
HP BladeSystem and Virtual Connect Flex-10 or FlexFabric components into an existing network.
•
FCoE Cookbook for HP Virtual Connect
This guide provides concept, implementation details, troubleshooting and use case scenarios of Fibre
Channel over Ethernet through FIP Snooping using FC-BB-5 with HP Virtual Connect.
•
HP BladeSystem c-Class Virtual Connect Support Utility User Guide
This guide provides instructions for using the Virtual Connect Support Utility, which enables
administrators to upgrade VC-Enet and VC-FC firmware and to perform other maintenance tasks
remotely on both HP BladeSystem c7000 and c3000 enclosures using a standalone, Windows-based,
HP-UX, or Linux command line utility.
Documentation resources
6
•
Release Notes
Release notes document new features, resolved issues, known issues, and important notes for each
release of the Virtual Connect product and support utility.
The HP Virtual Connection Migration Guide technical white paper on the HP website
(http://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/?docId=emr_na-c03885329)
provides you with procedures to migrate from HP VC 1/10 Ethernet modules to HP Virtual Connect
Flex-10/10D modules and retain VC-administered MAC and WW identifiers unchanged throughout the
migration.
Documentation resources
7
Planning the installation
Virtual Connect overview
HP Virtual Connect is a set of interconnect modules and embedded software for HP BladeSystem c-Class
enclosures. VC implements server edge virtualization between the server and the data center infrastructure so
networks can communicate with individual servers or pools of HP BladeSystem server blades. Upgrade,
replace, or move server blades within the enclosures without visible changes to the external LAN and SAN
environments. The external networks connect to a shared resource server pool rather than to individual
servers. VC cleanly separates server enclosure administration from LAN and SAN administration. VC
simplifies the setup and administration of server connections and includes the following components:
•
HP Virtual Connect Manager
•
VC-Enet modules:
o
HP VC Flex-10 10Gb Ethernet Module for BladeSystem c-Class
o
HP VC FlexFabric 10Gb/24-port Module for BladeSystem c-Class
o
HP VC FlexFabric-20/40 F8 Module for BladeSystem c-Class
o
HP VC Flex-10/10D Module for BladeSystem c-Class
NOTE: Using a Flex-10 capable NIC with an HP VC Flex-10 or FlexFabric module provides the
ability to divide a 10Gb NIC into four FlexNICs with configurable bandwidth.
•
VC-FC modules:
o
HP VC 4Gb Fibre Channel Module for BladeSystem c-Class (enhanced NPIV)
o
HP VC 8Gb 24-Port Fibre Channel Module for BladeSystem c-Class
o
HP VC 8Gb 20-Port Fibre Channel Module for BladeSystem c-Class
NOTE: Beginning with VC 4.10, the HP 4GB Virtual Connect Fibre Channel Module is no longer
supported.
VC modules support HP BladeSystem Enclosures and all server blades and networks contained within the
enclosure:
•
VC-Enet modules enable connectivity to data center Ethernet switches. VC-Enet modules can also be
directly connected to other types of devices, such as printers, laptops, rack servers, and network storage
devices.
•
VC-FC and FlexFabric modules enable connectivity of the enclosure to data center FC switches. Every
FC fabric is limited in the number of switches it can support, but the VC-FC and FlexFabric modules do
not appear as switches to the FC fabric and do not count against FC fabric limits.
For information on module support of enclosures and configurations, see the product QuickSpecs on the
HP website (http://www.hp.com/go/qs).
VCM is embedded on VC-Enet modules and is accessed through a web-based GUI or CLI. These interfaces
are also accessible from Onboard Administrator.
Planning the installation 8
A basic VC domain includes a single HP c-Class BladeSystem c7000 Enclosure for a total of 16 servers (or
up to 32 servers if the double-dense option is enabled), or a single HP c-Class BladeSystem c3000 Enclosure
for a total of 8 servers (or up to 16 servers if the double-dense option is enabled). For more information on
the double-dense option, see "Double-dense server bay option." Within the domain, any server blade with
the requisite LAN or SAN devices can access any LAN or SAN connected to a VC module, and a server
blade of a given processor type (Integrity or X86) can be used as a spare for any server blade of the same
processor type within the same enclosure, as long as the server has the requisite number and type of
connections. Using the network access groups feature, the network administrator can clearly define a
separation of networks based on their allowed functionality and prevent the server administrator from
assigning specific network combinations in the same server profile.
By stacking (cabling) the VC-Enet modules together within the domain and connecting the VC-FC or
FlexFabric module FC uplinks on the same bay of all enclosures to the same FC switch, every server blade in
the domain can be configured to access any external network or fabric connection. With this configuration,
you can use VCM to deploy and migrate a server blade profile to any server in the Virtual Connect domain
without changing external LAN or SAN configurations.
Beginning with VC 4.10, the FTP service on VC-Enet modules is disabled by default. The VCSU software
temporarily enables and disables the FTP service during firmware upgrades of VC-FC modules as needed.
More recent versions of VC use SFTP instead of FTP for firmware upgrades.
Each version of VC is tested and supported with one or more SPPs. For a list of supported SPPs that must be
installed, see the VC release notes.
VC module supported firmware
The following table lists all Virtual Connect modules and the highest firmware supported on that module.
Module
Highest VC firmware supported
HP Virtual Connect FlexFabric-20/40 F8 Module
4.31
HP Virtual Connect Flex-10/10D Module
4.31
HP Virtual Connect FlexFabric 10Gb/24-port Module
4.31
HP Virtual Connect Flex-10 10Gb Ethernet Module
4.31
HP Virtual Connect 8Gb 24-Port Fibre Channel Module
4.31
HP Virtual Connect 8Gb 20-Port Fibre Channel Module
4.31
HP Virtual Connect 4Gb Fibre Channel Module
4.31
HP 4Gb Virtual Connect Fibre Channel Module
4.01
HP 1/10Gb-F Virtual Connect Ethernet Module
3.61
HP 1/10Gb Virtual Connect Ethernet Module
3.61
Using multiple enclosures
Observe the following information:
•
A single domain supports up to four c7000 enclosures.
c3000 enclosures are not supported in multiple enclosure domains.
•
If double-dense mode is enabled in the Domain Setup Wizard, each enclosure can support a total of
128 servers.
Planning the installation 9
•
Stacking cables are used to connect multiple enclosures. This allows all VC-Enet modules to be
interconnected and redundantly stacked.
•
When the domain stacking mode is configured, stacking cables connect the primary slice of each
enclosure. The primary slice is the primary and standby interconnect modules for the enclosure.
•
All enclosures must have the same FC, FlexFabric, or Flex-10/10D module configuration.
For example, if bays 1 and 2 of the Primary Enclosure contain FlexFabric-20/40 F8 modules, then bays
1 and 2 of Remote Enclosures 1, 2, and 3 must also contain FlexFabric-20/40 F8 modules.
•
A total of 16 Ethernet and 16 VC-FC type modules can be installed in a multi-enclosure domain.
Each FlexFabric module counts as one Ethernet and one VC-FC module. Combinations of FlexFabric,
VC-Enet and VC-FC modules are allowed as long as the 16-module limit for each module type (Ethernet
and FC) is not exceeded in the domain.
•
VC-FC or FlexFabric modules must be in the same bay of all enclosures and connected to the same FC
switch to enable profile mobility.
•
All FC-capable modules in the same horizontally adjacent bay pair (bays 1-2, 3-4, and so on) must be
of the same type and position in all enclosures.
•
Multi-enclosure double-dense domains require similar and compatible VC-FC modules in bays 5, 6, 7,
and 8 in all enclosures when FC connectivity is required. If a multi-enclosure double-dense configuration
contains incompatible VC-FC modules in bays 5, 6, 7, or 8 in any of the enclosures, some or all of the
compatible VC-FC modules in the remote enclosures might be designated INCOMPATIBLE after import.
•
Be sure all Onboard Administrator and VC module management interfaces within the same VC domain
are on the same lightly loaded subnet and highly reliable network.
If the management network is overloaded, configuration attempts may be disabled until the connectivity
is re-established and synchronized with the domain.
•
HP recommends using a static IP address for Onboard Administrator.
•
Be sure all Onboard Administrators use the same user credentials. VCSU uses the primary credentials
for the remote enclosures to propagate firmware updates to all VC modules in each enclosure.
•
When both Primary and Standby modules in the base enclosure are taken down for maintenance or
lose power and are no longer present in the domain, the management capabilities in the VC domain
are lost. Both the Primary and Standby modules in the base enclosure must be recovered to regain
management access to the VC domain.
If network and fabric uplinks are defined on the remaining enclosures, the servers continue to have
network and storage access.
Pre-deployment planning
During the planning phase, the LAN and server administrator must determine how each server blade will
connect to the network and on which IP network and VLAN the server will reside. In a traditional network,
these connections are established through physical cables. If a move from one network to another is required,
the cables must also be moved. Virtual Connect provides a wire-once implementation when VC modules are
connected to upstream or core switches and the VC networks and server profiles are defined. Assigning a
server profile to a server blade completes the physical connection to the core network. If a server blade fails
or moves, all of the configuration parameters can be transferred easily to the new server.
Before beginning installation, complete the following tasks:
Planning the installation 10
•
Be sure that the firmware revisions on all VC modules in the domain are at the same revision level. The
active VCM does not allow incompatible modules to be managed as part of the same VC domain.
•
Be sure that OA, iLO, server blade system ROM, Ethernet option ROM, and FC option ROM firmware
are up-to-date.
•
Determine which mezzanine cards, HBAs, and interconnect modules are going to be used and where
they will be installed in the enclosure. For installation and information on mapping server ports to
interconnect bays, see the appropriate HP BladeSystem enclosure setup and installation guide on the
HP website
(http://h17007.www1.hp.com/us/en/enterprise/servers/solutions/info-library/index.aspx?cat=bla
desystem).
•
If your organization requires the use of secure protocols and standards, consider the security
requirements and restrictions of enabling FIPS mode ("Virtual Connect FIPS mode of operation" on page
34).
For a current status on FIPS certification, see the HP website
(http://government.hp.com/Certifications.aspx).
•
•
Determine the Ethernet stacking cable layout, and ensure that the proper cable and transceiver options
are ordered. Stacking cables enable any Ethernet NIC from any server to be connected to any of the
Ethernet networks defined for the enclosure using stacking links.
o
For information on stacking links, see "Stacking links (on page 23)."
o
For information on stacking cable configurations, see "Recommended stacking connections (on
page 24)."
o
For information on supported cable and transceiver options, see the Virtual Connect module
QuickSpecs on the HP website (http://www.hp.com/go/vc/manuals).
Determine which Ethernet networks will be connected to or contained within the enclosure.
Most installations will have multiple Ethernet networks, each typically mapped to a specific IP subnet.
Virtual Connect Ethernet networks can be contained completely within the enclosure for server-to-server
communication, or connected to external networks through rear panel ports (uplinks). For each network,
the administrator must use the VCM to identify the network by name and to define any external port
connections.
•
Determine which Fibre Channel fabrics will be connected to the enclosure.
Each uplink has a capability of aggregating up to 16 server HBA N-port links into an N-port uplink
through the use of NPIV.
•
Coordinate with data center personnel to ensure Ethernet network cable connections and Fibre Channel
cable connections to the enclosure are installed or scheduled to be installed.
•
Determine the Ethernet MAC address range to be used for the servers within the enclosure.
Server and networking administrators should fully understand the selection and use of MAC address
ranges before configuring the enclosure. For more information, see "MAC address settings (on page
74)."
•
Determine the FC World Wide Name (WWN) range to be used for servers within the enclosure.
Server and storage administrators should fully understand the selection and use of WWN ranges before
configuring the enclosure. For more information, see "WWN settings (on page 89)."
•
Identify the administrators for the Virtual Connect environment, and identify what roles and
administrative privileges they will require. The VCM classifies each operation as requiring server,
network, domain, or storage privileges. A single user may have any combination of these privileges.
Planning the installation 11
For more information, see the information on local users in the HP Virtual Connect for c-Class
BladeSystem User Guide on the HP website (http://www.hp.com/go/vc/manuals).
IMPORTANT: If you plan on using VC-assigned MAC addresses and WWNs and are also
working with server software that will be licensed by MAC addresses or WWNs, assign server
profiles before deploying an image through RDP or attaching a license.
Hardware setup overview
The following steps provide an overview of setting up the interconnect modules:
1.
Install and set up the enclosure. See the appropriate HP BladeSystem enclosure quick install instructions
on the HP website
(http://h17007.www1.hp.com/us/en/enterprise/servers/solutions/info-library/index.aspx?cat=bla
desystem).
2.
Install the interconnect modules ("Installation" on page 15).
To enable FIPS mode for the domain, be sure to configure the Virtual Connect Ethernet modules ("Virtual
Connect FIPS mode of operation" on page 34).
Plan your installation carefully. After the VC domain has been created, the position and type of the
primary and backup VC modules cannot be changed without deleting and recreating the domain.
3.
Install stacking links ("Recommended stacking connections" on page 24).
4.
Connect the VC-Enet module uplinks to data center networks. The network administrator should have
already installed the network cables into the rack with the proper labels. See "Connecting Virtual
Connect Ethernet module uplinks (on page 47)."
5.
Connect data center FC fabric links (if applicable).
6.
Note the default DNS name, user name, and password settings for the primary VC module, available
on the module Default Network Settings label.
The primary VC module is the first VC-Enet module in an odd-numbered interconnect bay.
7.
Note the default DNS name, user name, and password for the HP Onboard Administrator, available on
the module Default Network Settings label. See the HP BladeSystem Onboard Administrator User
Guide on the HP website (http://www.hp.com/go/oa).
8.
Apply power to the enclosures. See "Default module configuration (on page 13)." Also see the
appropriate HP BladeSystem enclosure quick install instructions on the HP website
(http://h17007.www1.hp.com/us/en/enterprise/servers/solutions/info-library/index.aspx?cat=bla
desystem).
9.
Use the HP Onboard Administrator for basic setup of the enclosures (including enclosure name and
passwords). See the HP BladeSystem Onboard Administrator User Guide on the HP website
(http://www.hp.com/go/oa).
10.
Be sure that all Virtual Connect interconnect module management interfaces and server blade iLO
interfaces have valid IP and gateway addresses using one of the following methods:
o
Run DHCP on the management network connected to the Onboard Administrator.
o
Configure the Onboard Administrator to set enclosure bay IP addresses. See "Virtual Connect and
EBIPA (on page 22)."
11.
Be sure that OA, iLO, server blade system ROM, Ethernet option ROM, and FC option ROM firmware
are current.
12.
Access VCM using one of the following methods:
Planning the installation 12
o
Use a web link from within the Onboard Administrator GUI or use the dynamic DNS name from the
Default Network Settings label. See "Accessing HP Virtual Connect Manager (on page 60)."
o
Access the VCM CLI remotely through an SSH session. See the HP Virtual Connect Manager
Command Line Interface User Guide on the HP website (http://www.hp.com/go/vc/manuals).
IMPORTANT: For proper management of enclosure devices there must be an Ethernet
connection from the Onboard Administrator module to the external management network. For
information on Onboard Administrator module cabling, see the HP BladeSystem Onboard
Administrator User Guide.
Default module configuration
When VC modules are inserted into an enclosure that is not yet part of a Virtual Connect domain, the
modules are configured to provide basic connectivity. After a Virtual Connect domain is defined for an
enclosure, server blades within that enclosure are isolated from all external network and fabric connections
until configured explicitly within VCM.
When not part of a Virtual Connect domain, each VC-Enet module is configured so that all server ports
connected to that module are connected to a single network, which is then connected to a single uplink. To
provide greater bandwidth, you can use LACP to aggregate additional ports on that module, as long as they
are connected to the same external switch. For aggregation of links to an external switch, the external switch
must support dynamic creation of link aggregation groups using the IEEE 802.3ad LACP. All stacking links
are disabled. This default configuration enables connectivity testing between server NICs and devices
outside the enclosure prior to Virtual Connect domain configuration.
When not part of a Virtual Connect domain, all of the VC-FC Module uplink ports are grouped into an uplink
port group and dynamically distribute connectivity from all server blades across all available uplink ports.
Virtual Connect Manager setup overview
The following steps provide an overview of setting up VCM:
1.
Log in and run the domain setup wizard ("HP Virtual Connect Domain Setup Wizard" on page 63).
a. Import the enclosure.
b. Name the Virtual Connect domain.
c.
Set up local user accounts and privileges.
TIP: If you want to setup network access groups, uncheck the "Start the Network Setup Wizard"
checkbox on the Finish screen of the Domain Setup Wizard.
2.
Define network access groups. For more information about network access groups, see "Network
Access Groups screen" in the user guide.
a. Select Network Access Group from the Define pull-down menu.
b. Set up network access groups. For more information about creating network access groups, see
"Define Network Access Group screen" in the user guide.
3.
Run the network setup wizard ("HP Virtual Connect Network Setup Wizard" on page 73).
a. Assign the MAC addresses used by server blade Ethernet network adapters within the Virtual
Connect domain ("MAC Address Settings" on page 74).
b. Configure server VLAN tagging support.
Planning the installation 13
c.
4.
Set up the networks.
Run the Fibre Channel setup wizard.
a. Select a WWN range to be used by server blade FC HBAs ("WWN settings" on page 89).
b. Define the SAN fabrics.
5.
If you created associated networks using the network setup wizard, all networks are assigned to the
Default network access group. You must be sure that all networks are in the proper network access
group before running the server profile setup wizard. For more information about editing network
access groups, see "Edit Network Access Group screen" in the user guide.
6.
Run the server profile setup wizard ("HP Virtual Connect Manager Server Profile Setup Wizard" on
page 94).
a. Assign serial numbers to server blades within the domain.
b. Create a server profile definition.
c.
Assign server profiles.
d. Name server profiles.
e. Create server profiles.
After an enclosure is imported into a Virtual Connect domain, server blades that have not been assigned a
server profile are isolated from all networks to ensure that only properly configured server blades are
attached to data center networks.
A server profile can be assigned and defined for each device bay so that the server blade can be powered
on and connected to a deployment network. These profiles can then later be modified or replaced by another
server profile.
A server profile can also be assigned to an empty bay to enable deployment at a later date.
Planning the installation 14
Installation
Installation requirements
CAUTION: Always use blanks to fill empty spaces in enclosures. This arrangement ensures
proper airflow. Using an enclosure without the proper blanks results in improper cooling that can
lead to thermal damage.
Observe the following requirements:
•
In all Virtual Connect configurations, a VC-Enet or FlexFabric module must be installed in the enclosure.
The embedded VCM operates on this module.
•
VC-Enet modules are used typically in pairs to provide access to all Ethernet controllers on the server
blade.
•
The specific interconnect bays with Ethernet connectivity depend on mezzanine card locations within
the server blade.
•
For c3000 enclosures, when two Fibre Channel mezzanine cards are installed in slots 2 and 3 of a
full-height server blade, the VC Manager only creates Fibre Channel connections and assigns WWNs
to the ports associated with the Fibre Channel mezzanine card in slot 2. This restriction does not apply
for c7000 enclosures.
•
For each Ethernet mezzanine port you want to manage with VCM, install a VC-Enet, HP VC
FlexFabric-20/40 F8 Module, or HP VC FlexFabric 10Gb/24-port Module in the interconnect bay
connected to that port. For more information, see the appropriate HP BladeSystem enclosure setup and
installation guide.
•
For Ethernet connections, Virtual Connect can be configured to assign or migrate MAC addresses for
device bay ports connected to VC-Enet or FlexFabric modules.
•
For Fibre Channel connections, FlexFabric module SFP ports can be connected only to Fibre Channel
switch ports that support N_port_ID virtualization. To verify that NPIV support is provided, see the
firmware documentation that ships with the Fibre Channel switch.
•
When using optional transceiver modules, or when using stacking cables to connect multiple VC-Enet
modules or multiple FlexFabric modules, order the cables and transceiver modules separately. For more
information, see the HP Virtual Connect QuickSpecs on the HP website
(http://www.hp.com/go/vc/manuals).
•
All modules in the enclosure require a valid and unique IP address, and all modules must be on the same
subnet. Use a DHCP server or the Onboard Administrator EBIPA feature to assign each module an IP
address.
•
For server or I/O interconnect hardware changes that involve adding or removing Flex-10 functionality,
the profile assigned to a server or server bay must be removed, all hardware changes performed, and
the profile reassigned. Otherwise, indeterminate network operation might occur. For more information,
see "Upgrading or removing an HP Virtual Connect Flex-10, HP Virtual Connect FlexFabric, or HP
Virtual Connect Flex-10/10D module (on page 54)."
Additional information
Installation 15
•
For the most up-to-date support information, see the HP website (http://www.hp.com/storage/spock).
Simple registration is required.
•
For more information on the association between the server blade mezzanine connectors and the
interconnect bays, see the HP BladeSystem enclosure setup and installation guide that ships with the
enclosure. During server blade installation, the location of the mezzanine card determines the
installation location of the interconnect modules.
•
For specific interconnect module port connection information for each server blade, see the HP
BladeSystem enclosure setup and installation guide that ships with the enclosure. Connections differ by
server blade type.
•
For more information on BladeSystem port mapping, see the HP BladeSystem enclosure setup and
installation guide that ships with the enclosure.
•
For the most current product information, see the release notes on the HP website
(http://www.hp.com/go/vc/manuals).
Supported configurations
The following table outlines the Ethernet, Fibre Channel, and enclosure support for each version of Virtual
Connect.
VC firmware version
Enclosure
FlexFabric
Support per
domain
Ethernet
support per
domain
FC support per Enclosures per
domain
single VC
domain
1.10
c3000
—
—
—
1.10
c7000
—
Up to 8 modules Up to 4 modules 1
1.20
c3000
—
Up to 4 modules Up to 2 modules 1
2.10/3.00/3.10
c7000
—
2.10/3.00/3.10
c3000
—
Up to 16
Up to 16
Up to 4
modules
modules
Up to 4 modules Up to 2 modules 1
3.15/3.17/3.30/3.51
/3.60/
3.70/3.75/4.01/4.10
c7000
Up to 16
modules*
Up to 16
modules
3.15/3.17/3.30/3.51
/3.60/
3.70/3.75/4.01/4.10
/
4.20/4.30/4.31
c3000
—
Up to 4 modules Up to 2 modules 1
4.20/4.30/4.31
c7000
Up to 16
modules*
Up to 16
modules
Up to 16
modules
Up to 16
modules
—
Up to 4
Up to 4
*Each FlexFabric module counts as one Ethernet and one VC-FC module. Combinations of FlexFabric, VC-Enet, and
VC-FC modules are allowed as long as the 16-module limit for each module type (Ethernet and FC) is not exceeded in the
domain.
HP BladeSystem c3000 Enclosure supported configurations
The following tables show several typical, supported configurations for an HP BladeSystem c3000 Enclosure.
In the following tables, "Other" indicates any c-Class interconnect module including a VC, Pass-Thru, or
switch.
[Bay 1]
VC Ethernet
[Bay 2]
VC Ethernet
Installation 16
[Bay 3]
Other/empty
[Bay 4]
Other/empty
[Bay 1]
VC Ethernet
[Bay 2]
VC Ethernet
[Bay 3]
VC Ethernet
[Bay 4]
VC Ethernet
[Bay 1]
VC Ethernet
[Bay 2]
VC Ethernet
[Bay 3]
VC-FC
[Bay 4]
VC-FC
[Bay 1]
Other/empty
[Bay 2]
Other/empty
[Bay 3]
VC Ethernet
[Bay 4]
VC Ethernet
IMPORTANT: The HP Virtual Connect FlexFabric 10Gb 24-port Module and HP Virtual Connect
Flex-Fabric-20/40 F8 Module are not supported in c3000 enclosures.
The use of an HP VC-Enet in bay 1 and a Fibre Channel module (for example, VC-FC, SNA
switch, or FC pass-thru) in bay 2 is not supported in c3000 enclosures.
IMPORTANT: The HP Virtual Connect Flex10/10D Module is supported in c3000 enclosures as
an Ethernet only module.
HP BladeSystem c7000 Enclosure supported configurations
The following tables show a number of typical, supported configurations for an HP BladeSystem c7000
Enclosure.
In the following tables, "Other" indicates any c-Class interconnect module including a VC, Pass-Thru, or
switch.
[Bay 1]
VC Ethernet
[Bay 2]
Empty
[Bay 3]
Other/empty
[Bay 4]
Other/empty
[Bay 5]
Other/empty
[Bay 6]
Other/empty
[Bay 7]
Other/empty
[Bay 8]
Other/empty
[Bay 1]
VC Ethernet
[Bay 2]
VC Ethernet
[Bay 3]
Other/empty
[Bay 4]
Other/empty
[Bay 5]
Other/empty
[Bay 6]
Other/empty
[Bay 7]
Other/empty
[Bay 8]
Other/empty
[Bay 1]
Other/empty
[Bay 2]
Other/empty
[Bay 3]
VC Ethernet*
[Bay 4]
VC Ethernet
[Bay 5]
Other/empty
[Bay 6]
Other/empty
[Bay 7]
Other/empty
[Bay 8]
Other/empty
*Requires minimum VC v3.10 firmware
VC Ethernet
[Bay 2]
VC Ethernet
[Bay 3]
Other/empty
[Bay 4]
Other/empty
[Bay 5]
VC Ethernet
[Bay 6]
VC Ethernet
[Bay 7]
Other/empty
[Bay 8]
Other/empty
[Bay 1]
VC Ethernet
[Bay 2]
VC Ethernet
[Bay 3]
VC Ethernet
[Bay 4]
VC Ethernet
[Bay 1]
Installation 17
[Bay 5]
VC Ethernet
[Bay 6]
VC Ethernet
[Bay 7]
Other/empty
[Bay 8]
Other/empty
[Bay 1]
VC Ethernet
[Bay 2]
Empty
[Bay 3]
VC-FC
[Bay 4]
Empty
[Bay 5]
Other/empty
[Bay 6]
Other/empty
[Bay 7]
Other/empty
[Bay 8]
Other/empty
[Bay 1]
VC Ethernet
[Bay 2]
VC Ethernet
[Bay 3]
VC-FC
[Bay 4]
VC-FC
[Bay 5]
Other/empty
[Bay 6]
Other/empty
[Bay 7]
Other/empty
[Bay 8]
Other/empty
[Bay 1]
VC Ethernet
[Bay 2]
VC Ethernet
[Bay 3]
VC Ethernet
[Bay 4]
VC Ethernet
[Bay 5]
VC-FC
[Bay 6]
VC-FC
[Bay 7]
Other/empty
[Bay 8]
Other/empty
[Bay 1]
VC Ethernet*
[Bay 2]
VC Ethernet
[Bay 3]
VC Ethernet
[Bay 4]
VC Ethernet
VC-FC
[Bay 6]
VC-FC
[Bay 5]
[Bay 8]
VC-FC
[Bay 7]
VC-FC
* This configuration only applies to enclosures with full-height servers.
VC Ethernet
[Bay 2]
VC Ethernet
[Bay 3]
VC-FC
[Bay 4]
VC-FC
[Bay 5]
VC Ethernet
[Bay 6]
VC Ethernet
[Bay 7]
Other/empty
[Bay 8]
Other/empty
[Bay 1]
VC Ethernet
[Bay 2]
VC Ethernet
[Bay 3]
VC-FC
[Bay 4]
VC-FC
[Bay 5]
VC Ethernet
[Bay 6]
VC Ethernet
[Bay 7]
VC Ethernet
[Bay 8]
VC Ethernet
[Bay 1]
VC Ethernet
[Bay 2]
VC Ethernet
[Bay 3]
Other/empty
[Bay 4]
Other/empty
[Bay 5]
VC-FC
[Bay 6]
VC-FC
[Bay 7]
Other/empty
[Bay 8]
Other/empty
[Bay 1]
VC Ethernet
[Bay 2]
VC Ethernet
[Bay 3]
VC-FC
[Bay 4]
VC-FC
[Bay 5]
VC-FC
[Bay 6]
VC-FC
[Bay 7]
Other/empty
[Bay 8]
Other/empty
[Bay 1]
VC Ethernet
[Bay 2]
VC Ethernet
[Bay 3]
VC Ethernet
[Bay 4]
VC Ethernet
[Bay 5]
VC Ethernet
[Bay 6]
VC Ethernet
[Bay 7]
VC Ethernet
[Bay 8]
VC Ethernet
[Bay 1]
Installation 18
Bay configuration requirements
Primary and backup VC modules
Observe the following requirements when installing primary and backup interconnect modules:
•
Plan your installation carefully. After the VC domain has been created, the position and type of the
primary and backup VC modules cannot be changed without deleting and recreating the domain.
IMPORTANT: The primary bay pair cannot be changed after the domain is created, including
through a restore configuration file operation.
•
To support failover configurations for VC, install two VC-Enet modules or two FlexFabric modules in
horizontally adjacent bays.
•
To support high availability of the Virtual Connect environment, HP recommends that VC-Enet modules
be used in horizontally adjacent interconnect bays. The embedded VCM operates in an active/standby
configuration. For more information, see "Failover and check-pointing (on page 52)."
•
To set up and configure VC, an odd-numbered interconnect bay must be populated with a VC-Enet
module or FlexFabric module. The lowest odd-numbered interconnect bay populated with a VC-Enet
module or FlexFabric module becomes the primary VC module.
Horizontally adjacent interconnect bays
Observe the following requirements when installing interconnect modules in horizontally adjacent bays:
•
Only like VC modules can reside in adjacent horizontal bays.
o
If a VC-Enet module is installed in an interconnect bay, the only module that can be installed in the
horizontally adjacent bay is another VC-Enet module of the same type.
o
HP Virtual Connect Flex-10 10Gb Ethernet Modules can reside in any bay. However, only another
HP Virtual Connect Flex-10 10Gb Ethernet Module can reside in an adjacent bay.
o
HP Virtual Connect Flex-10/10D Modules can reside in any bay. However, only another HP Virtual
Connect Flex-10/10D Module can reside in an adjacent bay.
o
HP Virtual Connect FlexFabric-20/40 F8 Modules can reside in any bay. However, only another HP
Virtual Connect FlexFabric-20/40 F8 Module can reside in an adjacent bay.
o
HP Virtual Connect FlexFabric 10Gb/24-port Modules can reside in any bay. However, only
another HP Virtual Connect FlexFabric 10Gb/24-port Module can reside in an adjacent bay
o
HP VC 8Gb 20-Port FC Modules can reside in any bay. However, only another HP VC 8Gb 20-Port
FC Module can reside in an adjacent bay.
o
HP Virtual Connect 8Gb 24-Port Fibre Channel Modules can reside in any bay. However, only
another 8Gb 24-Port Fibre Channel Module can reside in an adjacent bay.
o
Do not mix HP Virtual Connect 8Gb 24-Port FC Modules with HP Virtual Connect 4Gb or 8Gb
20-Port FC Modules in the horizontally adjacent interconnect bays connected to the same server
blade mezzanine card.
•
For c3000 enclosures, VC-FC modules are not supported in interconnect bay 2.
•
To avoid connectivity loss, do not install VC and non-VC modules in interconnect bays connected to the
same server blade mezzanine card. Non-VC modules cannot be installed in an interconnect bay
adjacent to a VC module.
•
Do not mix VC-Enet modules and VC-FC modules in interconnect bays connected to the same server
blade mezzanine card. This action generates an enclosure electronic keying error.
Installation 19
Odd numbered
bay
Horizontally
adjacent bay
Good
configuration?
Notes
VC FlexFabric
10Gb/24-port
VC FlexFabric
10Gb/24-port
Yes
—
VC FlexFabric
10Gb/24-port
Flex-10 Enet
No
Install only HP VC FlexFabric 10Gb/24-port
Modules into bays horizontally adjacent to bays
containing HP VC FlexFabric 10Gb/24-port
Modules.
VC
Yes
VC
FlexFabric-20/40 FlexFabric-20/40
F8
F8
VC FlexFabric
No
VC
FlexFabric-20/40 10Gb/24-port
F8
—
Install only HP VC FlexFabric-20/40 F8 Modules
into bays horizontally adjacent to bays containing
HP VC FlexFabric-20/40 F8 Modules.
Flex-10 Enet
Flex-10 Enet
Yes
—
Flex-10 Enet
Flex-10/10D
No
Install only HP Flex-10 10Gb VC-Enet Modules into
bays horizontally adjacent to bays containing HP
Flex-10 10Gb VC-Enet Modules.
Flex-10 Enet
4Gb FC with
enhanced NPIV
No
Do not mix Ethernet and FC modules in horizontally
adjacent bays.
Flex-10/10D
Flex-10/10D
Yes
—
Flex-10/10D
Flex-10 Enet
No
Install only HP VC Flex-10/10D Modules into bays
horizontally adjacent to bays containing HP VC
Flex-10/10D Modules.
4Gb FC
4Gb FC
Yes for 4.01
No for 4.10
Beginning with VC 4.10, the HP 4Gb VC-FC Module
is no longer supported.
4Gb FC
4Gb FC with
enhanced NPIV
Yes for 4.01
No for 4.10
Beginning with VC 4.10, the HP 4Gb VC-FC Module
is no longer supported.
4Gb FC with
enhanced NPIV
8Gb 20-Port FC
Yes
You can mix HP VC 4Gb FC Modules (with
enhanced NPIV) and HP 8Gb 20-Port FC Modules in
horizontally adjacent bays.
8Gb 24-Port FC
8Gb 20-Port FC
No
Do not mix HP 8Gb 24-Port FC and 8Gb 20-Port FC
Modules in horizontally adjacent bays.
VC FlexFabric
10Gb/24-port
8Gb 20-Port FC
No
The VC FlexFabric 10Gb/24-port module can only
have another VC FlexFabric 10Gb/24-port module
in the horizontally adjacent bay.
No
Do not mix VC and non-VC (switch or pass-thru)
modules in horizontally adjacent bays.
VC-Enet or VC-FC non-VC Other
HP Virtual Connect Flex-10 Module requirements
The following requirements apply to the installation or replacement of HP Virtual Connect Flex-10 10Gb
Ethernet Modules:
•
Only install HP Virtual Connect Flex-10 Modules into bays horizontally adjacent to bays containing
another HP Virtual Connect Flex-10 Module.
If any other type of module is installed, the second one discovered is set to UNKNOWN, and no
connections are made to the server NICs attached to the interconnect bay. The module is set to
UNKNOWN because it is removed automatically from the VC domain when removed physically from
the interconnect bay.
Installation 20
•
If an HP Virtual Connect Flex-10 Module is connected to a Flex-10 NIC that corresponds to an Ethernet
connection in a server profile, then replacing the module with any other type of Virtual Connect Ethernet
module requires that all network uplinks be removed from the module before replacement. For more
information on module removal, see "Interconnect module removal and replacement (on page 52)."
If the replacement module is not removed from the GUI, the module is marked as INCOMPATIBLE, and
no connections are made to the server NICs attached to the interconnect bay.
•
An empty interconnect bay horizontally adjacent to a bay containing an HP Virtual Connect Flex-10
Module is treated as if it has a Flex-10-compatible Ethernet module for server configuration. If the
corresponding server NIC is Flex-10, it is partitioned according to the connections in the server profile.
Adding a module that does not support Flex-10 when the corresponding server is configured for Flex-10
results in the module being set to INCOMPATIBLE.
HP Virtual Connect Flex-10/10D Module requirements
The following requirements apply to the installation or replacement of HP Virtual Connect Flex-10/10D
Modules:
•
Only install HP Virtual Connect Flex-10/10D Modules into bays horizontally adjacent to bays
containing another HP Virtual Connect Flex-10/10D Module.
If any other type of module is installed, the second one discovered is set to UNKNOWN, and no
connections are made to the server NICs attached to the interconnect bay. The module is set to
UNKNOWN because it is removed automatically from the VC domain when removed physically from
the interconnect bay.
•
If an HP Virtual Connect Flex-10/10D Module is connected to a Flex-10 NIC that corresponds to an
Ethernet connection in a server profile, then replacing the module with any other type of Virtual Connect
Ethernet module requires that all network uplinks be removed from the module before replacement. For
more information on module removal, see "Interconnect module removal and replacement (on page
52)."
If the replacement module is not removed from the GUI, the module is marked as INCOMPATIBLE, and
no connections are made to the server NICs attached to the interconnect bay.
•
An empty interconnect bay horizontally adjacent to a bay containing an HP Virtual Connect
Flex-10/10D Module is treated as if it has a Flex-10-compatible Ethernet module for server
configuration. If the corresponding server NIC is Flex-10, it is partitioned according to the connections
in the server profile. Adding a module that does not support Flex-10 when the corresponding server is
configured for Flex-10 results in the module being set to INCOMPATIBLE.
•
An HP Virtual Connect Flex-10/10D Module can only be used in a domain running VC firmware v3.70
or higher, otherwise the module is marked as UNKNOWN.
•
When the HP Virtual Connect Flex-10/10D Module has ports configured to carry FCoE traffic, those
ports do not support stacking.
HP Virtual Connect FlexFabric 10Gb/24-port Module
requirements
The following requirements apply to the installation or replacement of HP Virtual Connect FlexFabric
10Gb/24-port Modules:
Installation 21
•
For full storage network compatibility, each server blade attached to the HP VC FlexFabric
10Gb/24-port Module must have either an embedded or mezzanine-based FlexFabric converged
network adapter.
•
Only install an HP VC FlexFabric 10Gb/24-port Module in an interconnect bay horizontally adjacent
to a bay that contains an HP VC FlexFabric 10Gb/24-port Module.
•
The HP VC FlexFabric 10Gb/24-port Module only supports external stacking for Ethernet traffic. When
the HP VC FlexFabric 10Gb/24-port Module has ports configured to carry Fibre Channel or FCoE
traffic, those ports do not support stacking.
•
An HP VC FlexFabric 10Gb/24-port Module can only be used in a domain running VC firmware v3.15
or higher, otherwise the module is marked as UNKNOWN.
HP Virtual Connect FlexFabric-20/40 F8 Module requirements
The following requirements apply to the installation or replacement of HP Virtual Connect FlexFabric-20/40
F8 Modules:
•
The HP VC FlexFabric-20/40 F8 Module is supported only on the following c7000 SKUs:
o
5XXXXX-B21
o
6XXXXX-B21
o
7XXXXX-B21
This module is not supported in c3000 enclosures.
For information on updated SKUs, see the QuickSpecs on the HP website
(http://www.hp.com/go/qs).
•
If more than two HP VC FlexFabric-20/40 F8 Modules are installed in a c7000 enclosure, the ambient
operating temperature cannot exceed 30В°C (86В°F).
•
Do not install more than six HP VC FlexFabric-20/40 F8 Modules in a c7000 enclosure.
•
HP recommends a c7000 enclosure with a 10-fan configuration when HP Virtual Connect
FlexFabric-20/40 F8 Modules are installed.
•
For full storage network compatibility, each server blade attached to the HP VC FlexFabric-20/40 F8
Module must have either an embedded or mezzanine-based FlexFabric converged network adapter.
•
Only install an HP VC FlexFabric-20/40 F8 Module in an interconnect bay horizontally adjacent to a
bay that contains an HP VC FlexFabric-20/40 F8 Module.
•
The HP VC FlexFabric-20/40 F8 Module only supports external stacking for Ethernet traffic. When the
HP VC FlexFabric-20/40 F8 Module has ports configured to carry Fibre Channel or FCoE traffic, those
ports do not support stacking.
•
An HP VC FlexFabric-20/40 F8 Module can only be used in a domain running VC firmware v4.20 or
higher, otherwise the module is marked as UNKNOWN.
Virtual Connect and EBIPA
Enclosure Bay IP Addressing is used to specify IP addresses for the interconnect modules, which are then
provided to the modules by the Onboard Administrator.
For information on using IPv6 with Virtual Connect, see the HP Virtual Connect for c-Class BladeSystem User
Guide on the HP website (http://www.hp.com/go/vc/manuals).
Installation 22
Because Virtual Connect communicates with other components through the Onboard Administrator, special
considerations are required when using EBIPA with Virtual Connect Ethernet modules:
•
The Onboard Administrator must be on the same IP subnet as all Virtual Connect modules.
•
The Onboard Administrator IP address must be set properly before changing the IP addresses of the
Virtual Connect modules.
Stacking Links
Stacking links are used to add VC-Enet modules to a VC domain. This feature enables any server NIC
physically connected to a VC module to be connected to any Ethernet network. By using stacking links, a
single pair of uplinks can function as the data center network connections for the entire Virtual Connect
domain.
Observe the following guidelines:
•
Use uplink ports to connect modules to data center switches or stack VC-Enet modules and enclosures.
•
Virtual Connect does not support stacking for FC modules. Each VC-FC module or FlexFabric module
configured to carry Fibre Channel or FCoE traffic requires uplink connections to the external FC SAN
environment.
•
The following modules only support external stacking for Ethernet traffic:
o
HP VC FlexFabric 10Gb/24-port
o
HP VC FlexFabric-20/40 F8
o
HP VC Flex-10/10D
When these modules have ports configured to carry Fibre Channel or FCoE traffic, those ports do not
support stacking.
•
Observe the following information when Ethernet modules are horizontally-adjacent:
o
HP VC Flex-10 Enet modules
Uplink ports X7 and X8 form internal stacking links between the modules when left unpopulated.
o
HP VC FlexFabric 10Gb/24-Port modules
Uplink ports X7 and X8 form internal stacking links between the modules when left unpopulated.
o
HP VC Flex-10/10D Modules
Ports X11, X12, X13, and X14 are dedicated internal stacking links.
o
HP VC FlexFabric-20/40 F8 Modules
Ports X9 and X10 are dedicated internal stacking links.
•
Virtual Connect automatically detects when one VC-Enet module port is connected to another VC-Enet
module port within the domain and changes the port ID indicator color to amber to indicate a stacking
link.
•
All VC-Enet modules within the Virtual Connect domain must be interconnected. Any combination of
1Gb and 10Gb cables can be used to interconnect the modules. If connecting HP VC FlexFabric-20/40
F8 modules, 40Gb stacking cables can be used.
•
ISL ports provide stacking links between horizontally adjacent modules.
•
In partially stacked domains, the combination of a stacking link and horizontally-adjacent Enet modules
is considered a logical interconnect. Logical interconnects are formed in horizontal and primary slice
stacking modes.
Installation 23
To configure a partially stacked domain, see "Configuring partially stacked domains (on page 27)."
•
Be sure to connect any stacking cables before running the network setup wizard.
For recommended stacking cable configurations, see "Recommended stacking connections (on page
24)."
Recommended stacking connections
Use the following table for recommended stacking connections.
Single enclosure stacking
Modules (top to
bottom)
Stacking two modules
HP Virtual Connect
FlexFabric
10Gb/24-port Modules
HP Virtual Connect
Flex-10 10Gb Ethernet
Modules
HP Virtual Connect
FlexFabric-20/40 F8
Modules
Stacking four modules
•
•
•
•
HP Virtual Connect
FlexFabric
10Gb/24-port
Modules
HP Virtual Connect
FlexFabric
10Gb/24-port
Modules
HP Virtual Connect
FlexFabric
10Gb/24-port
Modules
HP Virtual Connect
Flex-10 10Gb
Ethernet Modules
Installation 24
Single enclosure stacking
Modules (top to
bottom)
•
•
HP Virtual Connect
FlexFabric
10Gb/24-port
Modules
HP Virtual Connect
FlexFabric-20/40 F8
Modules
Stacking six modules
•
•
•
•
•
•
•
•
•
HP Virtual Connect
FlexFabric
10Gb/24-port
Modules
HP Virtual Connect
FlexFabric
10Gb/24-port
Modules
HP Virtual Connect
FlexFabric
10Gb/24-port
Modules
HP Virtual Connect
FlexFabric
10Gb/24-port
Modules
HP Virtual Connect
FlexFabric
10Gb/24-port
Modules
HP Virtual Connect
Flex-10 10Gb
Ethernet Modules
HP Virtual Connect
FlexFabric
10Gb/24-port
Modules
HP Virtual Connect
Flex-10 10Gb
Ethernet Modules
HP Virtual Connect
Flex-10/10D
Modules
Installation 25
Single enclosure stacking
Modules (top to
bottom)
•
•
•
HP Virtual Connect
FlexFabric
10Gb/24-port
Modules
HP Virtual Connect
FlexFabric
10Gb/24-port
Modules
HP Virtual Connect
FlexFabric-20/40 F8
Modules
Stacking eight modules
•
•
•
•
•
•
•
•
HP Virtual Connect
FlexFabric
10Gb/24-port
Modules
HP Virtual Connect
FlexFabric
10Gb/24-port
Modules
HP Virtual Connect
FlexFabric
10Gb/24-port
Modules
HP Virtual Connect
Flex-10/10D
Modules
HP Virtual Connect
FlexFabric
10Gb/24-port
Modules
HP Virtual Connect
FlexFabric
10Gb/24-port
Modules
HP Virtual Connect
Flex-10 10Gb
Ethernet Modules
HP Virtual Connect
Flex-10 10Gb
Ethernet Modules
Installation 26
Single enclosure stacking
Modules (top to
bottom)
•
•
•
•
HP Virtual Connect
FlexFabric
10Gb/24-port
Modules
HP Virtual Connect
FlexFabric
10Gb/24-port
Modules
HP Virtual Connect
Flex-10 10Gb
Ethernet Modules
HP Virtual Connect
FlexFabric-20/40 F8
Modules
The 1000BASE-T links can be used as stacking links of up to 100 m (328 ft). Ports with different connector
types can be aggregated if the link speed is the same. For example, CX4 and SFP+ ports both running at
10G can be aggregated to provide enhanced throughput for the stacking link.
NOTE: The CX4 interface uses the same physical connector as InfiniBand, but InfiniBand cables
are tuned differently and will not perform as well in CX4 applications. HP recommends
purchasing CX4 cable assemblies that meet the IEEE CX4 specifications and support 10-Gigabit
communication at distances from 3 m to 15 m (9.84 ft to 49.20 ft).
For information on supported cables, see the module QuickSpecs on the HP website
(http://www.hp.com/go/vc/manuals).
HP strongly recommends full redundancy of VC-Enet modules. The recommended stacking configurations
have redundant connections. If a stacking cable is disconnected or fails, the Ethernet packets within the
Virtual Connect domain are automatically re-routed to the uplink through the redundant path. This
configuration helps preserve network connectivity if an Ethernet interconnect module fails or is removed.
Configuring partially stacked domains
A partially stacked domain uses logical interconnects to create stacking configurations in a VC domain. A
logical interconnect is the combination of horizontally adjacent Enet modules and the internal stacking link
that connects them.
The following stacking modes are available:
•
Full Stacking is the default stacking mode for the VC domain. In Full Stacking, all Ethernet modules
within the domain are connected by horizontal cross connects or by stacking cables.
•
Horizontal Stacking disables all vertical stacking links. In horizontal stacking mode, each horizontal
bay pair is a separate logical interconnect. For example, if bay 1 and bay 2 are populated, they form
a logical interconnect.
•
Primary Slice Stacking disables all stacking links outside of the primary slice. The primary slice is the
primary and standby interconnect modules for the enclosure. In primary slice stacking, the primary slice
is a logical interconnect.
When configuring horizontal or primary slice stacking, observe the following:
•
A brief network outage occurs when you change the domain stacking mode.
Installation 27
•
The following connections must reside within their configured logical interconnect for proper
functionality. These connections must not span outside of their logical interconnect:
o
Network uplink ports
o
Shared uplink sets
o
Monitored ports
o
sFlow ports
When configuring networks, uplink ports are filtered to ensure that all ports belong to the same logical
interconnect.
•
If there are connections not configured as stacking links between modules, the ports are linked and
function as normal uplink ports.
•
Server to server communications between logical interconnects requires a connection between the
logical interconnects.
•
Multiple enclosure configurations are supported and require that the primary slices of the enclosures be
connected with stacking cables.
•
Profile migrations are not supported in multi-enclosure domains.
•
Double-dense mode is not supported.
•
HP BladeSystem c3000 Enclosures are not supported.
•
HP recommends enabling Smart Link.
To configure the domain stacking mode, see the latest versions of the following documents in the Virtual
Connect Information Library (http://www.hp.com/go/vc/manuals):
•
HP Virtual Connect for c-Class BladeSystem User Guide
•
HP Virtual Connect Manager Command Line Interface for c-Class BladeSystem User Guide
Network loop protection
To avoid network loops, Virtual Connect first verifies that only one active uplink exists per network from the
Virtual Connect domain to the external Ethernet switching environment. Second, Virtual Connect makes sure
that no network loops are created by the stacking links between Virtual Connect modules.
•
One active link—A VC uplink set can include multiple uplink ports. To prevent a loop with broadcast
traffic coming in one uplink and going out another, only one uplink or uplink LAG is active at a time. The
uplink or LAG with the greatest bandwidth should be selected as the active uplink. If the active uplink
loses the link, then the next best uplink is made active.
•
No loops through stacking links—If multiple VC-Enet modules are used, they are interconnected using
stacking links, which might appear as an opportunity for loops within the VC environment. For each
individual network in the Virtual Connect environment, VC blocks certain stacking links to ensure that
each network has a loop-free topology.
Enhanced network loop protection detects loops on downlink ports, which can be a Flex-10 logical port or
physical port. The feature applies to Flex-10 logical function if the Flex-10 port is operating under the control
of DCC protocol. If DCC is not available, the feature applies to a physical downlink port.
Enhanced network loop protection uses two methods to detect loops:
Installation 28
•
It periodically injects a special probe frame into the VC domain and monitors downlink ports for the
looped back probe frame. If this special probe frame is detected on downlink ports, the port is
considered to cause the loop condition.
•
It monitors and intercepts common loop detection frames used in other switches. In network
environments where the upstream switches send loop detection frames, the VC Enet modules must
ensure that any downlink loops do not cause these frames to be sent back to the uplink ports. Even
though VC probe frames ensure loops are detected, there is a small time window depending on the
probe frame transmission interval in which the loop detection frames from the external switch might loop
through down link ports and reach uplink ports. By intercepting the external loop detection frames on
downlinks, the possibility of triggering loop protection on the upstream switch is eliminated. When
network loop protection is enabled, VC-Enet modules intercept the following types of loop detection
frames:
o
PVST+ BPDUs
o
Procurve Loop Protect frames
When the network loop protection feature is enabled, any probe frame or other supported loop detection
frame received on a downlink port is considered to be causing the network loop, and the port is disabled
immediately until an administrative action is taken. The administrative action involves resolving the loop
condition and clearing the loop protection error condition. The "loop detected" status on a port can be
cleared by one of the following administrative actions:
•
Restart loop detection by issuing "reset" loop protection from the CLI or GUI
•
Unassign all networks from the port in "loop detected" state
The SNMP agent supports trap generation when a loop condition is detected or cleared.
Virtual Connect provides the ability to enable or disable network loop protection. The feature is enabled by
default and applies to all VC-Enet modules in the domain. Network loops are detected and server ports can
be disabled even prior to any enclosure being imported.
A loop-protect reset command resets and restarts loop detection for all server ports in a “loop-detected” error
condition.
For each individual network in the Virtual Connect environment, VC blocks certain stacking links to ensure
that each network has a loop-free topology. VCM determines which stacking links are used to forward traffic
by determining the shortest route from the module with the active uplink to the remaining stacked VC-Enet
modules. For optimal stacking strategies, see HP Virtual Connect for the Cisco Network Administrator on the
Functionality & Value tab of the HP BladeSystem Technical Resources website
(http://www.hp.com/go/bladesystem/documentation).
Connecting multiple enclosures
Virtual Connect supports the connection of up to four c7000 enclosures, which can reduce the number of
network connections per rack and also enables a single VC Manager to control multiple enclosures. A single
set of cables can be used to carry all external Ethernet traffic from a single rack.
Multiple enclosure support enables up to four c7000 enclosures to be managed within a single Virtual
Connect domain.
Stacking multiple enclosures enables the management of up to four enclosures from a single control point. VC
Manager operates in the primary enclosure, and it enables up to three additional remote enclosures of the
same type to be added as part of a single VC domain. The locally managed primary enclosure must be
Installation 29
imported into the domain before importing additional (remote) enclosures. If a failure occurs, the standby
module in the primary enclosure takes over.
The VC Manager in the primary enclosure accesses all remote modules and OAs over the management
network. The OAs for each enclosure to be managed as part of a VC domain must be on the same
management subnet along with all of the VC-Enet and VC-FC modules that are in each enclosure. All
enclosure OAs and VC modules within the same VC domain must be on the same lightly loaded subnet. HP
recommends that the OA IP addresses used are configured to be static. The VC-Enet modules use stacking
cables between enclosures to route network traffic from any server port to any uplink port within the VC
domain.
The VC-FC modules and FlexFabric FC-configured ports do not support stacking. Connecting multiple
enclosures requires identical FC and FlexFabric module bay configuration in each enclosure. For more
information, see "FC and FlexFabric bay configuration using multiple enclosures (on page 32)."
Installation 30
Multi-enclosure double dense domains require similar and compatible FC modules in bays 5, 6, 7, and 8 in
all enclosures. If a multi-enclosure double dense configuration contains incompatible FC modules in bays 5,
6, 7, or 8 in either the local or remote enclosures, some or all of the compatible FC modules in the remote
enclosures might be designated INCOMPATIBLE after import.
To add additional enclosures to a domain, see the HP Virtual Connect for c-Class BladeSystem User Guide
on the HP website (http://www.hp.com/go/vc/manuals).
Multiple enclosure requirements
Observe the following requirements when connecting multiple enclosures:
•
A single domain supports up to four c7000 enclosures.
•
Each enclosure must have at least one supported VC-Enet module installed.
•
If the domain stacking mode is configured to full stacking, all VC-Enet modules must be interconnected
and redundantly stacked.
•
If the domain stacking mode is configured to horizontal or primary slice stacking, the primary slice of
each enclosure must be connected with stacking cables.
•
All enclosures must have the same FC and FlexFabric module configuration.
For example, if bays 1 and 2 of the Primary Enclosure contain FlexFabric-20/40 F8 modules, then bays
1 and 2 of Remote Enclosures 1, 2, and 3 must also contain FlexFabric-20/40 F8 modules.
•
All enclosures must have the same HP VC Flex-10/10D module configuration.
For example, if bays 1 and 2 of the Primary Enclosure contain HP VC Flex-10/10D modules, then bays
1 and 2 of Remote Enclosures 1, 2, and 3 must also contain HP VC Flex-10/10D modules.
•
A total of 16 Ethernet and 16 VC-FC type modules can be installed in a multi-enclosure domain.
•
Each FlexFabric module counts as one Ethernet and one VC-FC module. Combinations of FlexFabric,
VC-Enet and VC-FC modules are allowed as long as the 16-module limit for each module type (Ethernet
and FC) is not exceeded in the domain.
Additional constraints apply for the FlexFabric-20/40 F8 module ("HP Virtual Connect
FlexFabric-20/40 F8 Module requirements" on page 22).
•
All Onboard Administrators and VC modules must be on the same lightly loaded and highly reliable
management Ethernet network and IP subnet.
•
The VC-FC and FlexFabric FC-configured uplink port configuration must be identical across all
enclosures.
•
The Onboard Administrator firmware must be version 3.11 or higher. HP recommends using the latest
version available.
•
All Onboard Administrators must use the same user credentials. VCSU uses the primary credentials for
the remote enclosure.
•
When both Primary and Standby modules in the base enclosure are taken down for maintenance or
lose power and are no longer present in the domain, the management capabilities in the VC domain
are lost. Both the Primary and Standby modules in the base enclosure must be recovered to regain
management access to the VC domain.
If network and fabric uplinks are defined on the remaining enclosures, the servers continue to have
network and storage access.
Installation 31
FC and FlexFabric bay configuration using multiple enclosures
The VC-FC modules and FlexFabric FCoE or FC-configured uplinks do not support stacking. To ensure server
profile mobility, the VC-FC and FlexFabric bay configurations must be identical for all enclosures in the
domain.
For example, in a multi-enclosure domain with a total of four enclosures, if bays 3 and 4 of the Primary
Enclosure contain VC-FC modules, then bays 3 and 4 of Remote Enclosures 1, 2, and 3 must also contain
VC-FC modules. If bays 1 and 2 of the Primary Enclosure contain FlexFabric modules, then bays 1 and 2 of
Remote Enclosures 1, 2, and 3 must also contain FlexFabric modules. The following illustration shows a valid
VC-FC and FlexFabric bay configuration.
Sample valid VC-FC and FlexFabric bay configuration
Installation 32
The following illustration shows an invalid VC-FC and FlexFabric bay configuration. For VC-FC bay
compatibility, Bay 4 in Remote Enclosure 1 is empty, and Bay 3 of Remote Enclosure 2 has an Ethernet
module present. For FlexFabric bay compatibility, Bay 2 in Remote Enclosure 1 is empty, and Bay 1 of
Remote Enclosure 2 has an Ethernet module present.
Sample invalid VC-FC and FlexFabric bay configuration
Installation 33
Directly connecting VC domains
In a multi-enclosure domain configuration with properly installed stacking cables, each network defined in
the domain is available to all server profiles in the domain without requiring any additional uplink ports. This
configuration enables you to establish an open communication path between two or more enclosures.
You can also directly associate the uplinks from two enclosures from different domains so that servers in the
two domains attached to the networks configured for those uplinks can communicate with one another. This
configuration establishes a private communication path between the two enclosures. However, the
communication path is public for all of those servers and applications associated with it. Traffic would not
flow from an upstream switch over that direct connection.
The two enclosures can communicate with each other by a dedicated uplink port or a shared uplink port
defined on each enclosure. These uplinks on the two enclosures can be “teamed” using LACP because both
domains run LACP active. The link between the two enclosures cannot have any additional active links
connected to other targets. Only networks defined for that link can be shared between the two enclosures.
Virtual Connect FIPS mode of operation
Beginning with version 4.30, Virtual Connect supports FIPS 140-2 Level 1 security requirements. Enabling
FIPS mode requires the use of secure protocols, standards, and procedures within the VC domain. The Virtual
Connect FIPS certification is currently based on the standards described in Federal Information Processing
Standards Publication 140-2 (http://csrc.nist.gov/publications/PubsFIPS.html).
The term FIPS mode is used throughout this document to describe the feature, not the validation status. For
information about current FIPS status of this or any other firmware version, see the following documents:
•
Cryptographic Module Validation Program FIPS 140-1 and FIPS 140-2 Modules In Process List
(http://csrc.nist.gov/groups/STM/cmvp/documents/140-1/140InProcess.pdf)
•
FIPS 140-1 and FIPS 140-2 Vendor List
(http://csrc.nist.gov/groups/STM/cmvp/documents/140-1/1401vend.htm)
FIPS mode information and guidelines
Before enabling FIPS mode, observe the following information:
•
The OA should be enabled with FIPS mode before VCM.
If FIPS mode cannot be set on the OA, perform the following procedures before enabling FIPS mode on
VCM:
o
If it exists, delete the VC domain.
o
Clear the VC mode from the OA.
A partial VC domain state is created when VCM discovers the local OA in VC mode. Be sure to clear
the partial VC domain state by powering off and then powering on the primary VC Enet module.
•
When entering or exiting FIPS mode, the VC domain is deleted.
•
The firmware must be updated to version 4.30 or higher before FIPS mode can be enabled.
•
A rollback or downgrade to firmware earlier than 4.30 is not supported once the domain is in FIPS
mode.
•
VC Fibre Channel modules are incompatible and cannot be configured for FIPS mode.
Installation 34
•
•
The status of VC Fibre Channel modules is displayed as incompatible.
When a VC-Enet module is not in FIPS mode and the domain is in FIPS mode, the status of that module
is displayed as incompatible.
The VCM cannot configure modules that are not enabled with FIPS mode.
•
VC domain configuration files created in a FIPS enabled domain cannot be used in a non-FIPS domain.
•
VC domain configuration files created in a non-FIPS domain cannot be used in a FIPS enabled domain.
•
VC domain configuration files are deleted when FIPS mode is enabled or disabled.
When FIPS mode is enabled, security is increased across the domain. The following features are restricted:
•
FTP and TFTP
•
TACACS+ authentication
•
RADIUS authentication
•
Automated deployment
•
Configurable user roles
•
Administrator password recovery
•
USB firmware updates
•
SNMPv1 and SNMPv2
•
MD5 authentication and DES encryption for SNMPv3
•
Remote logging, except when using stunnel for encryption
•
Short passwords
•
Weak passwords
By default, the password strength is set to strong and the minimum password length must be 8 or more
characters. VCM uses SCP and SFTP protocols instead of FTP and TFTP.
TLS 1.2 is the default communication security protocol for a FIPS enabled domain. Verify the following
components support TLS 1.2:
•
The OA version
OA firmware versions prior to 4.10 do not support TLS 1.2.
•
The LDAP server
•
The terminal emulator you use for SSH
•
The browser you use to access the VCM web interface
If a component does not support TLS 1.2, you can use the VCM CLI or web interface to configure VCM to
support all TLS versions.
To verify browser settings, see "Configuring browser support (on page 58)."
Enabling FIPS mode
Enable FIPS mode by setting the DIP switch on the primary VC-Enet or FlexFabric module. To enable FIPS
mode:
1.
Verify the interconnect module firmware version is at least 4.30/4.31.
Installation 35
If the firmware version is not 4.30/4.31, upgrade the firmware to 4.31.
CAUTION: Before upgrading the firmware, be sure no plans exist to downgrade or rollback
firmware. Once the domain is in FIPS mode, the firmware cannot be downgraded.
2.
Remove the Virtual Connect Ethernet module from the interconnect bay.
3.
Remove the access panel.
Removing the access panel is not required on HP VC FlexFabric-20/40 F8 modules. The DIP switch is
accessible without removing the access panel.
4.
Locate the DIP switch ("Component identification" on page 104).
5.
Find DIP switch 3, and then set to the ON position. Be sure that all other switches remain in the OFF
position.
OFF OFF ON OFF
6.
Install the access panel.
7.
Install the Virtual Connect Ethernet module into the interconnect bay and allow the module to power up
and reach a fully booted and operational state (approximately 1 minute).
8.
Log in to VC Manager and verify the domain or the module is in FIPS mode.
FIPS mode indicators (domain)
VCM indicates if the domain is in FIPS mode by displaying the following icon in the banner.
The VCM CLI prompt indicates if the domain is in FIPS mode by displaying the following prompt:
FIPS->
FIPS mode indicators (VC Ethernet modules)
If a module is not enabled with FIPS mode, it is displayed as incompatible. To identify an incompatible
module, use the Interconnect Bays screen.
Installing a VC-Enet module
The VC-Enet module can be used in an HP BladeSystem c7000 Enclosure or an HP BladeSystem c3000
Enclosure. The following illustrations show the VC-Enet module being installed in a c7000 enclosure.
Installation 36
To install the component:
1.
Remove the interconnect blank.
NOTE: HP Virtual Connect works optimally in enclosures configured with HP Virtual Connect
interconnect modules only.
2.
Prepare the VC-Enet module for installation (HP VC Flex-10 10Gb Ethernet Module shown).
Installation 37
3.
Install the module into the interconnect bay (HP VC Flex-10 10Gb Ethernet Module shown). Push the
module in slowly and smoothly until it is firmly seated.
4.
If the Virtual Connect configuration includes three or more VC-Enet modules, install stacking links
(typically 10GBASE-CX4 cables) between the modules. For more information, see "Connecting Virtual
Connect Ethernet Module uplinks (on page 47)."
5.
Connect the data center network cables to the appropriate VC-Enet module faceplate ports. This step
can be deferred until after setup of the Virtual Connect Manager software. See "Default module
configuration (on page 13)."
The SFP+ ports can be used to connect to the data center if they are populated with a supported
pluggable SFP or SFP+ transceiver module.
IMPORTANT: For proper thermal operation, always install SFP dust covers in SFP ports without
SFP transceivers installed.
6.
Remove the perforated portion of the Default Network Setting label that extends beyond the faceplate
of the primary module, or record the information contained on the label.
The Default Network Settings label contains the DNS name, user name, and password of the primary
interconnect module. This information is required for access to VCM.
7.
Power on and configure the enclosure. For more information, see the appropriate HP BladeSystem
enclosure setup and installation guide on the HP website
(http://h17007.www1.hp.com/us/en/enterprise/servers/solutions/info-library/index.aspx?cat=bla
desystem).
8.
Connect a workstation to the data center network hosting the HP BladeSystem Onboard Administrator
for the enclosure.
9.
Start and log on to the workstation.
10.
Open a compatible web browser.
11.
Log on to the HP BladeSystem Onboard Administrator. For specific instructions, see the HP BladeSystem
Onboard Administrator User Guide on the HP website (http://www.hp.com/go/oa).
12.
Verify the HP Onboard Administrator firmware. HP recommends using the latest version available.
Using IPv6 requires OA 4.01 or higher. For specific instructions, see the HP BladeSystem Onboard
Administrator User Guide on the HP website (http://www.hp.com/go/oa).
Installation 38
IMPORTANT: For proper Virtual Connect operation, always assign an IP address to each server
blade iLO and interconnect module.
13.
Be sure that the server blade BIOS and NIC options ROM are at the appropriate revision level. For more
information, see the HP website (http://www.hp.com/go/bladesystemupdates).
14.
Review the Onboard Administrator bay summary screens to verify that each server blade iLO and
interconnect module has been assigned an IP address. Each IP address must be valid and unique, and
all iLOs and VC modules must be on the same subnet. For more information, see the HP BladeSystem
Onboard Administrator User Guide on the HP website (http://www.hp.com/go/oa).
15.
From the Onboard Administrator enclosure overview screen, click the Virtual Connect Manager link.
The VCM logon screen appears.
16.
Enter the user name from the Default Network Settings label into the Username field.
17.
Enter the password from the Default Network Settings label into the Password field, and then click Sign
In.
The HP Virtual Connect Manager Setup Wizard screen appears.
18.
Use the VC Manager to administer the VC-Enet module for the enclosure.
After an enclosure is imported into a Virtual Connect domain, server blades that have not been assigned a
server profile are isolated from all networks to ensure that only properly configured servers are attached to
data center networks.
A pre-deployment server profile can be defined within VCM for each device bay so that the server blade can
be powered on and connected to a deployment network. These profiles can then be modified at a later time
or replaced by another server profile. For more information on server profiles, see the HP Virtual Connect for
c-Class BladeSystem User Guide on the HP website (http://www.hp.com/go/vc/manuals).
Installing a VC FlexFabric module
For individual FlexFabric module installation requirements, see "Installation requirements (on page 15)."
To install the component:
1.
Remove the interconnect blank.
Installation 39
NOTE: HP Virtual Connect works optimally in enclosures configured with HP Virtual Connect
interconnect modules only.
2.
Prepare the FlexFabric module for installation. (HP Virtual Connect FlexFabric 10/24-port Module
shown).
3.
Install the FlexFabric module into the interconnect bay.
4.
If the enclosure configuration includes more than one VC module, connect any necessary stacking
cables between the modules.
The FlexFabric module supports stacking links for Ethernet traffic only. For more information, see the HP
Virtual Connect for c-Class BladeSystem User Guide on the HP website
(http://www.hp.com/go/vc/manuals).
5.
Connect the data center network cables to any FlexFabric module port not being used for Virtual
Connect stacking links.
Installation 40
Any available port can be used to connect to the data center for Ethernet traffic. If the port requires a
pluggable module, then the port must be populated with a supported pluggable transceiver module that
is compatible with the data center port type.
6.
If the FlexFabric module is being configured for Fibre Channel traffic, connect the data center SAN
switch ports to ports X1 through X4 of the module, or ports X1 through X8 on HP Virtual Connect
FlexFabric-20/40 F8 Modules.
IMPORTANT: For proper thermal operation, always install dust covers in QSFP+, SFP+, or SFP
ports without transceivers installed.
7.
Remove the perforated portion of the Default Network Settings label that extends beyond the faceplate
of one of the VC-Enet module or FlexFabric module installed in the enclosure.
The Default Network Settings label contains the DNS name, user name, and password of the
interconnect module. This information is required for access to VCM.
8.
Connect a workstation to the data center network hosting the HP BladeSystem Onboard Administrator
for the enclosure.
9.
Start and log on to the workstation.
10.
Open a web browser.
11.
Log on to the HP BladeSystem Onboard Administrator. If prompted, follow the steps in the OA First Time
Setup Wizard. For specific instructions, see the HP BladeSystem Onboard Administrator User Guide on
the HP website (http://www.hp.com/go/oa).
12.
Before accessing VCM, verify that the HP BladeSystem Onboard Administrator firmware is at the
recommended firmware version. For specific instructions, see the HP website
(http://www.hp.com/go/oa).
IMPORTANT: For proper Virtual Connect operation, always assign an IP address to each server
blade iLO and interconnect module.
13.
Verify that each server blade iLO and interconnect module has been assigned an IP address by
reviewing the bay summary screens in the Onboard Administrator. Each IP address must be valid and
unique, and all iLOs and Virtual Connect modules must be on the same subnet. For more information,
see the HP BladeSystem Onboard Administrator User Guide on the HP website
(http://www.hp.com/go/oa).
14.
From the enclosure overview screen, click Virtual Connect Manager.
The VCM logon screen appears.
15.
16.
In the Username field, type Administrator.
Enter the password from the Default Network Settings label into the Password field.
The HP Virtual Connect Manager Setup Wizard screen appears.
17.
Use VCM to administer the Virtual Connect Ethernet module for the enclosure. For more information, see
the HP Virtual Connect for c-Class BladeSystem User Guide on the HP website
(http://www.hp.com/go/vc/manuals).
Installing a VC-FC module
The VC-FC module can be used in an HP BladeSystem c7000 Enclosure or an HP BladeSystem c3000
Enclosure. The following illustrations show the VC-FC module being installed in a c7000 enclosure.
Installation 41
To install the component:
1.
Remove the interconnect blank.
NOTE: HP Virtual Connect works optimally in enclosures configured with HP Virtual Connect
interconnect modules only.
2.
Prepare the VC-FC module for installation (HP Virtual Connect 4Gb Fibre Channel Module shown).
Installation 42
3.
Install the VC-FC module into the interconnect bay (HP Virtual Connect 4Gb Fibre Channel Module
shown). Push the module in slowly and smoothly until it is firmly seated.
4.
Connect the data center SAN switch ports to the VC-FC module 1/2/4 Gb SFP ports.
IMPORTANT: For proper thermal operation, always install SFP dust covers in SFP ports without
SFP transceivers installed.
IMPORTANT: For proper Virtual Connect operation, always assign an IP address to each server
blade iLO and interconnect module.
5.
Review the Onboard Administrator bay summary screens to verify that each server blade iLO and
interconnect module has been assigned an IP address. Each IP address must be valid and unique, and
all iLOs and VC modules must be on the same subnet. For more information, see the HP BladeSystem
Onboard Administrator User Guide on the HP website (http://www.hp.com/go/oa).
6.
Configure the VC-FC module:
o
If VC-Enet modules are installed in the same enclosure, use VCM to administer VC-FC modules.
o
If VC-Enet modules are not installed in the same enclosure, the VC-FC module operates in the default
configuration only.
Installing DAC/AOC cables and transceivers
To install a DAC/AOC cable or a QSFP+, SFP+, or SFP transceiver , use the following procedures:
•
Installing a DAC/AOC cable ("Installing the cable" on page 43)
•
Installing a transceiver ("Installing the transceiver" on page 44)
Installing the cable
1.
If needed, remove the packaging and protective caps.
2.
Verify the cable is the correct type by checking the label on the transceiver.
3.
Remove the dust plug from the correct port.
Installation 43
4.
Align the transceiver in front of the port with the label facing up.
5.
Install the cable. (QSFP+ DAC cable shown)
Installing the transceiver
WARNING: To avoid serious injury, never look directly into an open transceiver port.
CAUTION: Disconnect all cables before removing or installing any transceivers or transceiver
adapters. Leaving the cable connected while handling the transceiver may damage the cable, the
cable connector, or the optical interfaces in the transceiver.
Do not remove and install transceivers more often than is necessary. Doing so can shorten the
useful life of the transceiver.
CAUTION: Do not remove the dust plugs from the transceiver or the connector until you are ready
to connect the cable. The plugs protect the ports and connectors from contamination and ambient
light.
NOTE: Transceivers may have a bail clasp latch or a pull tab latch. If installing a transceiver with
a bail clasp latch, be sure the latch is closed before connecting the cable.
To install a transceiver or transceiver adapter:
IMPORTANT: Use only HP approved transceivers.
1.
Verify the transceiver type by checking the label.
2.
Remove the dust plug from the correct port.
3.
Align the transceiver in front of the port with the label facing up.
4.
Install the transceiver:
Installation 44
o
SFP+
o
QSFP+
o
Transceiver adapter
If a cable needs to be connected, remove any dust plugs or covers, and then connect the cable.
Installation 45
Removing QSFP+, SFP+ or SFP transceivers
WARNING: To avoid serious injury, never look directly into an open transceiver port.
CAUTION: Disconnect all cables before removing or installing a QSFP+, SFP+ or SFP
transceiver, because of the potential damage to the cables, the cable connector, or the optical
interfaces in the transceiver.
Do not remove and install transceivers more often than is necessary. Doing so can shorten the
useful life of the transceiver.
1.
Disconnect all cables.
2.
Open the latch.
3.
Remove the transceiver. (SFP transceiver shown).
4.
Install dust plugs on the fiber-optic transceiver and rubber plugs on the fiber-optic cable.
CAUTION: Be sure to install the dust plugs on the fiber-optic transceiver and the rubber plugs on
the fiber-optic cable. The plugs and caps protect the transceiver ports and cables from
contamination and ambient light.
Factory default settings
The Virtual Connect Delete Domain operation returns all VC-FC modules to the factory default settings.
VC-FC modules that are physically removed from a VC domain can be returned to the factory default settings
when placed into a new enclosure by applying power, and then pressing and holding the reset button on the
front panel for at least 10 seconds. When moved from a VC domain and placed into an enclosure not part
of a VC domain, VC-FC modules retain assigned mappings until reset to the factory default.
Installation 46
Connecting Virtual Connect Ethernet module uplinks
Each interconnect module has several numbered Ethernet connectors. All of these connectors can be used to
connect to data center switches (uplink ports), or they can be used to stack Virtual Connect modules as part
of a single Virtual Connect domain (stacking ports). See "Recommended stacking connections (on page
24)."
Networks must be defined within VCM so that specific named networks can be associated with specific
external data center connections. These named networks can then be used to specify networking connectivity
for individual servers. The network connection can be between one or many networks to one or many uplink
ports:
•
One network to one port (unshared network)
•
One network to multiple uplink ports (unshared network)
•
Multiple networks to one port (shared uplink set)
•
Multiple networks to multiple ports (shared uplink set)
In addition, multiple networks can be connected to server downlink ports using server VLAN IDs. For more
information, see "Managing server profiles" in the user guide.
The following sections provide an overview of the types of external connections and their behaviors.
Mapping individual networks to individual external uplink ports
The simplest approach to connecting the defined networks to the data center is to map each network to a
specific external uplink port. This uplink port is defined by the following:
•
Enclosure name
•
Interconnect bay containing the VC-Enet module
•
Selected port on that module
Port status indicators can be used to locate a specific port or to provide additional status.
The following table shows an example of simple network mapping, where the Virtual Connect enclosure is
named Enclosure1 and VC-Enet modules are in interconnect module bays 1 and 2.
Network
Uplink port
Production_Network
Enclosure1:Bay1:PortX2
Dev_Network
Enclosure1:Bay1:Port4
Backup_Network
Enclosure1:Bay2:Port3
iSCSI_Storage_Network
Enclosure1:Bay2:PortX2
Installation 47
In this case, the Ethernet packets are passed unchanged between the server blades and the external
networks. Any VLAN tags added by the server or external switch are ignored and pass through the VC-Enet
modules.
The previous figure also shows a local connection between Server Blade 2 and Server Blade 16, which might
be used in a cluster or as a network heartbeat.
Mapping a single network to multiple uplinks (uplink port set)
A single network can be mapped to more than one external uplink port to provide improved throughput and
availability, referred to as an uplink port set. Review the following guidelines before mapping a single
network to an uplink port set:
•
External uplink ports within an uplink port set can be on the same VC-Enet module or on multiple VC-Enet
modules within the Virtual Connect domain.
•
Cables can be connected to one or more data center Ethernet switches.
•
When multiple external uplink ports are used for the same network, the VC-Enet modules provide
automatic loop prevention by enabling for a single active link or link set at any one time.
•
VC automatically chooses the uplink port that optimizes throughput and availability. Where possible,
links within the uplink port set automatically form a link aggregation group with LACP. This action
requires multiple uplink ports on a single VC-Enet module to be connected to an external switch that is
capable and configured to form link aggregation groups with LACP.
In the following example, a single network is mapped to four external uplink ports.
Network
Uplink port set
Production_Network
{ Enclosure1:Bay1:Port1
Enclosure1:Bay1:Port2
Enclosure1:Bay2:Port1
Enclosure1:Bay2:Port2 }
In this example, the ports from Bay 1 could be connected to one external switch, and the ports on Bay 2 could
be connected to a second switch. If the external switches support link aggregation, then this configuration
would provide an active 2-Gb link to one switch and a standby 2-Gb link to the other.
Installation 48
To make VCM aware of individual network connections, see "Define Ethernet Network screen" in the user
guide.
Mapping multiple networks to a single port in a shared uplink set
The network administrator can choose to reduce the number of cables between the Virtual Connect enclosure
and the data center switches by mapping multiple networks to a single, shared uplink port. In this case, a
network is not just mapped to an uplink port, but to a VLAN on that port. This configuration requires VLAN
tags to be added to each packet as it leaves the Virtual Connect domain and that packets entering the Virtual
Connect domain be tagged. The VLAN tag is stripped from packets entering the Virtual Connect domain
before they are routed to the appropriate server.
In the following example, an uplink port is defined as a shared uplink port so that it can then be used as the
external connection for multiple networks.
Shared_Uplink_Port_A = Enclosure1:Bay1:PortX2
Network
Shared uplink port and VLAN
Production_Network
Shared_Uplink_Port_A:VLAN_15
Dev_Network
Shared_Uplink_Port_A:VLAN_21
Backup_Network
Shared_Uplink_Port_A:VLAN_32
iSCSI_Storage_Network
Shared_Uplink_Port_A:VLAN_76
Because appropriate VLAN tags are added as the packets leave the enclosure, this type of uplink should not
be used in cases where VLAN tags are already added on the server itself. The system drops any Ethernet
packets with server-inserted VLAN tags that are received on networks connected to shared uplink ports.
To make VCM aware of shared network connections, see "Define Shared Uplink Set screen" in the user
guide.
Mapping multiple networks to a shared uplink set
It is also possible to map multiple VLAN-tagged networks to a set of shared uplink ports. The resulting shared
uplink set allows for the minimum number of cables while still providing for link aggregation and failover.
In the following example, a shared uplink set is first defined to provide aggregation and failover.
Shared_Uplink_Set_A = {Enclosure1:Bay1:PortX2, Enclosure1:Bay2:PortX2}
Installation 49
Network
Shared uplink set and VLAN
Production_Network
Shared_Uplink_Set_A:VLAN_15
Dev_Network
Shared_Uplink_Set_A:VLAN_21
Backup_Network
Shared_Uplink_Set_A:VLAN_32
iSCSI_Storage_Network
Shared_Uplink_Set_A:VLAN_76
In this example, all of the defined networks share a single active uplink port (such as
Enclosure1:Bay1:PortX2) using VLAN tagging, while the second link in the shared uplink set is available for
failover. The shared uplink set can also be constructed from multiple 1-Gb external ports.
To make VCM aware of shared network connections, see "Define Shared Uplink Set screen" in the user
guide.
Mapping FCoE networks to a shared uplink set
When mapping FCoE networks to a shared uplink set, the shared uplink set uplink port must be connected to
a supported FCoE switch that is capable of splitting the converged Enet and FCoE traffic out into native FC
or Enet, as it applies.
Configuration example using a Cisco Core switch
There are several ways to implement a redundant Virtual Connect configuration. This example provides a
reference for anyone unfamiliar with switch configurations. This example is just one of several ways to
connect an HP Virtual Connect to a Cisco Core switch. For more information, see HP Virtual Connect for the
Cisco Network Administrator on the Functionality & Value tab of the HP BladeSystem Technical Resources
website (http://www.hp.com/go/bladesystem/documentation).
Connecting Virtual Connect to a Cisco Core/distribution switch using a shared uplink set and VLAN tagging
done at the VC/data center boundary
In the following example, LACP is used on the Cisco Switch to connect to a shared uplink set using three
uplink ports. VLANs 10, 20, 30, and 40 from the network are tagged on the three shared uplink ports.
IMPORTANT: Change Channel Mode to LACP on the Cisco switch.
Installation 50
By default, all ports on a Catalyst 4500/4000 switch and a Catalyst 6500/6000 switch use channel
protocol PAgP and are not running LACP. For all ports concerned, you must change the channel mode to
LACP.
On switches running CatOS, you can only change channel mode per module. In the following example,
change the channel mode for slots 1 and 2 by using the following command:
set channelprotocol lacp module_number
Verify the changes by using the following command:
show channelprotocol.
CatOSSwitch (enable)
Mod 1 is set to LACP
CatOSSwitch (enable)
Mod 2 is set to LACP
CatOSSwitch (enable)
Channel
Module Protocol
------- -------1
LACP
2
LACP
3
PAGP
5
PAGP
set channelprotocol lacp 1
protocol.
set channelprotocol lacp 2
protocol.
show channelprotocol
On switches running Cisco IOS Software, specify which interfaces should be using LACP by entering the
following interface configuration command:
channel-protocol lacp:
CiscoIOSSwitch(config-if)#channel-protocol lacp
Example switch configuration of a Cat 6500 switch using IOS. Ports 7/46, 7/47, and 7/48 on the Cat
6500 switch are used to uplink to the Virtual Connect module:
interface Port-channel10
switchport
switchport trunk encapsulation dot1q
switchport trunk allowed vlan 10,20,30,40
switchport mode trunk
no ip address
interface GigabitEthernet7/46
description test-VC
switchport
switchport trunk encapsulation dot1q
switchport trunk allowed vlan 10,20,30,40
switchport mode trunk
no ip address
speed 1000
channel-protocol lacp
channel-group 10 mode active
!
interface GigabitEthernet7/47
description test-VC
switchport
switchport trunk encapsulation dot1q
switchport trunk allowed vlan 10,20,30,40
switchport mode trunk
no ip address
speed 1000
channel-protocol lacp
Installation 51
channel-group 10 mode active
!
interface GigabitEthernet7/48
description test-VC
switchport
switchport trunk encapsulation dot1q
switchport trunk allowed vlan 10,20,30,40
switchport mode trunk
no ip address
speed 1000
channel-protocol lacp
channel-group 10 mode active
Failover and check-pointing
VCM runs as a high-availability pair when VC-Enet modules are installed in horizontally adjacent
interconnect bays. The active VCM is usually on the lowest odd numbered bay when the enclosure is
powered up.
Each time a configuration is changed, it is written to local flash memory and then check-pointed to the
standby module. Configurations can also be backed up to a workstation using the GUI or Virtual Connect
Support Utility.
NOTE: HP recommends saving a configuration after each session and before updating
firmware.
Interconnect module removal and replacement
Virtual Connect modules
It is not necessary to remove the module from the domain if the module is not in use. The module is removed
automatically from the domain without user intervention.
Replacing a primary or backup VC module with a different VC module type is not allowed without first
deleting the domain.
If a module is in use and configured by the domain at the time it is physically removed from an enclosure, then
the module is marked as MISSING, and can only be replaced by a module of the same model and type. If
an in-use module is replaced by a module of a different type, then it is marked as INCOMPATIBLE by the
domain.
If a module being physically removed is the primary module of a primary bay pair, then it is marked as
MISSING and can only be replaced by a module of the same type.
A VC-Enet module is in use if any of the following conditions exist:
•
The module physically exists in an interconnect bay using VC release prior to 3.00.
•
The uplink and downlink ports of the module are being used by one or more networks, uplink sets, or
profiles.
•
Port monitoring is enabled for the interconnect module.
A VC-FC capable module is in use if any the following conditions exist:
•
The module physically exists in an interconnect bay using VC release prior to 3.00.
Installation 52
•
The uplink ports of the module are being used by a fabric that is being used by a profile.
•
The module is part of a FC bay group in a multi-enclosure configuration where other FC modules exist
in the bay group.
If a VC-FC module is replaced with a spare VC-FC module without powering down the servers, and if the
server has profiles assigned to it with FC connections, servers are allowed to log in for a brief period through
an uplink of the new module, provided that the uplink is connected to the fabric. Approximately 8 seconds
after discovering the new VC-FC module, VCM configures it with the correct information, mapping downlinks
to the correct uplinks. To work around this problem, power down the servers in the enclosure before
replacing or swapping FC modules. Alternatively, do not connect the VC-FC uplinks to the fabric until VCM
recognizes and configures the VC-FC module.
When adding VC interconnect modules to a VC managed enclosure, wait until the modules have been fully
integrated into the current domain before attempting to make configuration changes to the VC domain. These
changes include adding or editing networks, fabrics, profiles, and shared uplink sets. Verify that the domain
status is clear for the newly added interconnect module before making any changes to the configuration.
Modifying the configuration before the integration is complete can cause unexpected behavior such as
incorrect/invalid connections in a profile.
Upgrading to an HP Virtual Connect 8Gb 24-Port FC Module
Upgrading to an HP VC 8Gb 24-Port FC Module requires several important steps, depending on the starting
configuration.
Replacing an HP 4Gb VC-FC Module, HP VC 4Gb FC Module, or HP 8Gb 20-Port FC Module with an HP VC
8Gb 24-Port FC Module
1.
Upgrade the VC domain firmware to the latest supported version. See "VC module supported firmware
(on page 9)."
2.
Verify that the replacement will result in a good configuration. See "Multiple enclosure requirements (on
page 31)."
3.
Verify that the user has server and storage role permissions.
4.
Remove any FC profile connections that are connected to the interconnect bays being upgraded. To
remove the profile connections, un-assign the profile, and then delete the connections from the profile.
5.
If any FC SAN fabrics were created using uplinks from the interconnect bays that are being upgraded,
delete these FC SAN fabrics from the Virtual Connect domain.
6.
Physically remove the existing modules from BOTH horizontally adjacent bays for each enclosure in the
domain. In a double-dense domain, remove the modules from Bay 7 and Bay 8 when removing
modules in Bay 5 and Bay 6.
7.
Ensure that the VC-FC modules are no longer shown in the domain.
8.
Install the HP VC 8Gb 24-Port FC Modules.
9.
Re-create previously deleted FC SAN fabrics.
10.
Re-assign the server profiles, and then add the FC connections to the profiles.
Upgrading to an HP Virtual Connect 8Gb 20-Port FC Module
Replacing an HP 4Gb VC-FC Module or HP VC 4Gb FC Module with an HP VC 8Gb 20-Port FC Module
1.
Upgrade the VC domain firmware to the latest supported version. See "VC module supported firmware
(on page 9)."
Installation 53
2.
Physically remove the existing module.
3.
Install the HP VC 8Gb 20-port FC Module.
No additional steps are required.
Replacing an HP 8Gb 24-Port FC Module with an HP VC 8Gb 20-Port FC Module
1.
Upgrade the VC domain firmware to the latest supported version. See "VC module supported firmware
(on page 9)."
2.
Verify that the replacement will result in a good configuration. See "Multiple enclosure requirements (on
page 31)."
3.
Verify that the user has server and storage role permissions.
4.
Remove any FC profile connections that are connected to the interconnect bays being upgraded. To
remove a profile connection, un-assign the profile, and then delete the connections from the profile.
5.
If any FC SAN fabrics were created using uplinks from the interconnect bays that are being upgraded,
delete these FC SAN fabrics from the Virtual Connect domain.
6.
Physically remove the existing modules from BOTH horizontally adjacent bays for each enclosure in the
domain. In a double-dense domain, remove the modules from Bay 7 and Bay 8 when removing
modules in Bay 5 and Bay 6.
7.
Ensure that the VC-FC modules are no longer shown in the domain.
8.
Install the HP VC 8Gb 20-port FC Modules.
9.
Re-create previously deleted FC SAN fabrics.
10.
Re-assign the server profiles, and then add the FC connections to the profiles.
Possible errors
If the previous steps are not followed exactly, the module might be set to the UNKNOWN or INCOMPATIBLE
state depending on how the error state was reached. Physically remove the module. Then, insert the correct
module type.
If the previous steps have been followed and the server is not connecting properly to the network, power
down the server, and then power it back up.
Upgrading or removing an HP Virtual Connect Flex-10, HP Virtual
Connect FlexFabric, or HP Virtual Connect Flex-10/10D module
Upgrading an enclosure to Flex-10 or FlexFabric support or removing Flex-10 support requires several steps,
depending on the starting configuration.
•
For more information on individual module requirements, see "Installation requirements (on page 15)".
•
For detailed migration information, see the HP Virtual Connection Migration Guide technical white
paper on the HP website
(http://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/?docId=emr_na-c038853
29).
Replacing a Virtual Connect Ethernet module with an HP Virtual Connect Flex-10, HP FlexFabric, or HP
Flex-10/10D module in a horizontally adjacent bay pair hosting VC Manager (the horizontal bays housing
primary and/or backup modules)
Installation 54
CAUTION: Replacing the primary/backup bay pair modules with modules of a different type
requires the creation of a new VC domain, creating the probability that VC managed identifiers
(MAC, WWN, and serial numbers) could be assigned to different server ports or slots from the
original VC domain.
The HP Virtual Connection Migration Guide technical white paper on the HP website
(http://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/?docId=emr_na-c03
885329) details a procedure for upgrading to newer Virtual Connect modules while maintaining
the same VC-managed identifiers.
1.
Upgrade the VC domain firmware to the latest supported version. See "VC module supported firmware
(on page 9)".
2.
Delete the domain.
3.
Remove all network uplinks from the modules to be removed.
4.
Remove the existing modules from both horizontally adjacent bays.
5.
Install the HP Virtual Connect Flex-10, FlexFabric, or Flex-10/10D modules.
6.
Import one or more enclosures and create a new VC domain. If available, a user-created CLI script file
can accelerate VC domain recreation. However, be sure to verify the settings because VC-managed
identifiers, such as MAC, WWN, and serial numbers, might not match the original VC domain settings.
Replacing a Virtual Connect Ethernet module with an HP Virtual Connect Flex-10, HP FlexFabric, or HP
Flex-10/10D module in a horizontally adjacent bay pair not hosting VC Manager
1.
Upgrade the VC domain firmware to the latest supported version. See "VC module supported firmware
(on page 9)".
2.
Save the configuration.
3.
If any Flex-10 NICs with profile connections are connected to the interconnect bays being upgraded,
the profile connections must be removed. To remove a profile connection, unassign the profile
(recommended) or delete the connection from the profile.
4.
Remove all network uplinks from the modules to be removed.
5.
Remove the existing modules from both horizontally adjacent bays.
6.
Ensure that the modules are removed from the Virtual Connect GUI. If the modules still appear on the
GUI, there are still profiles with connections to the modules or networks with uplinks on the modules. Do
not proceed until the modules are removed.
7.
Install the HP Virtual Connect Flex-10, FlexFabric, or Flex-10/10D modules.
8.
Reassign the server profiles or add the connections to the profiles, depending on what was done in step
3.
Replacing an HP Virtual Connect Flex-10, HP FlexFabric, or HP Flex-10/10D module with a Virtual Connect
Ethernet module in a horizontally adjacent bay pair hosting VC Manager (the horizontal bays housing
primary and/or backup modules)
CAUTION: Replacing the primary/backup bay pair modules with modules of a different type
requires the creation of a new VC domain, creating the probability that VC managed identifiers
(MAC, WWN, and serial numbers) could be assigned to different server ports or slots from the
original VC domain.
The HP Virtual Connection Migration Guide technical white paper on the HP website
(http://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/?docId=emr_na-c03
885329) details a procedure for upgrading to newer Virtual Connect modules while maintaining
the same VC-managed identifiers.
Installation 55
1.
Delete the domain.
2.
Remove all network uplinks from the modules to be removed.
3.
Remove the existing Flex-10, FlexFabric, or Flex-10/10D modules from both horizontally adjacent
bays.
4.
Install the Virtual Connect Ethernet modules.
5.
Import one or more enclosures and create a new VC domain. If available, a user-created CLI script file
may accelerate VC domain recreation. However, be sure to verify the settings because VC-managed
identifiers, such as MAC, WWN, and Serial Numbers, might not match the original VC domain
settings.
Replacing an HP Virtual Connect Flex-10, HP FlexFabric, or HP Flex-10/10D module with a Virtual Connect
Ethernet module in a horizontally adjacent bay pair not hosting VC Manager
1.
If any Flex-10 NICs with profile connections are connected to the interconnect bays being upgraded,
then the profile connections must be removed. To remove a profile connection, unassign the profile
(recommended) or delete the connection from the profile.
2.
Remove all network uplinks from the modules to be removed.
3.
Remove the existing Flex-10, FlexFabric, or Flex-10/10D modules from both horizontally adjacent
bays.
4.
Ensure that the modules are removed from the Virtual Connect GUI. If the modules still appear on the
GUI, there are still profiles with connections to the modules or networks with uplinks on the modules. Do
not proceed until the modules are removed.
5.
Install the Virtual Connect Ethernet modules.
6.
Reassign the server profiles or add the connections to the profiles, depending on what was done in step
1.
Possible errors
If the previous steps are not followed exactly, the newly inserted module might be set to the UNKNOWN or
INCOMPATIBLE state, depending on how the error state was reached. To correct this error:
1.
Physically remove the module.
2.
Insert the original module.
3.
Ensure that all profiles have been unassigned.
4.
Remove the module.
5.
Verify that the module is removed from the GUI.
6.
Insert the correct module type.
If the previous steps have been followed and the server is not connecting properly to the network, power
down the server, and then power it back up.
Upgrading to an HP Virtual Connect FlexFabric module from a
VC-FC module
Replacing any VC-FC module with an HP VC FlexFabric module:
1.
Upgrade the VC domain firmware to the latest supported version. See "VC module supported firmware
(on page 9)."
Installation 56
2.
Verify that the replacement will result in a good configuration. See "Multiple enclosure requirements (on
page 31)."
3.
Verify that the user has server and storage role permissions.
4.
Remove any FC profile connections that are connected to the interconnect bays being upgraded by
deleting the connections from the profile.
5.
If any FC SAN fabrics were created using uplinks from the interconnect bays being upgraded, delete
these FC SAN fabrics from the Virtual Connect domain.
6.
Physically remove the existing modules from both horizontally adjacent bays.
7.
Ensure that the VC-FC modules are no longer shown in the domain.
8.
Replace the server blade FC HBA mezzanine cards with FlexFabric Adapter mezzanine cards.
9.
Install the HP VC FlexFabric Modules with the appropriate FC SFP+ transceivers.
10.
Recreate the previously deleted FC SAN fabrics.
11.
Add FCoE connections to the profiles.
12.
Power up the server and install the appropriate drivers for the FlexFabric Adapter mezzanine card.
Onboard Administrator modules
Replacing the OA in an enclosure containing only one OA causes the OA to leave VC mode. This mode
change requires VC Manager to re-establish credentials with the OA. During this process, VC Manager
rewrites all server settings and sets the state of the servers to "profile recovered." There should not be any
disruption to the servers, but the administrator should be sure that all servers have the correct MAC addresses
and WWNs. Powering off the server clears the "profile recovered" state. If any servers are rebooted or
power-cycled while the credential recovery occurs, the MAC addresses and WWNs might be returned to the
factory default settings.
Installation 57
HP Virtual Connect Manager
Configuring browser support
Access to the VCM GUI is provided through HTTPS (HTTP exchanged over an SSL-encrypted session) and
requires HTTPS (port 443) to be enabled on the management network.
The minimum supported screen resolution is 1024 x 768 with 256 colors. For optimal viewing, HP
recommends setting the screen resolution to 1280 x 1024.
Requirements
The VCM web interface requires an XSLT-enabled browser with support for JavaScript 1.3 or the equivalent.
The following browsers are supported:
•
Microsoft Internet Explorer 10.x and 11.x
•
Mozilla Firefox ESR 24 and 29.x
Browsers that provide the required functionality but do not appear in the previous list are not prevented from
running the application, but no support is offered for unlisted browsers.
If you receive a notice that your browser does not have the required functionality, examine your browser
settings to ensure they meet the following requirements or contact your administrator.
The use of third-party browser download managers is not supported or recommended when using Virtual
Connect. Using third-party download managers might cause some VC file download functionality to work
incorrectly, for example, when saving the domain configuration, downloading a support information file,
and so on.
The following browser settings must be enabled before running the application:
•
JavaScript
Client-side JavaScript is used extensively by this application. Check the browser settings to make sure
JavaScript is enabled before running the application.
•
ActiveX
When using Microsoft Internet Explorer with this application, ActiveX must be enabled. Check the
browser settings to make sure ActiveX is enabled before running the application.
•
Adobe Flash Player
VC 4.30/4.31 requires Adobe Flash Player 11.1 or higher before you can log in. HP recommends
updating to Adobe Flash Player 13 or higher for Windows and 11.2 for Linux systems.
The recommended Adobe Flash Player web browser plug-in can be downloaded and installed from the
Adobe website (http://get.adobe.com/flashplayer/), or downloaded as a standalone executable
from the Adobe website (http://www.adobe.com/downloads).
For the latest Adobe Flash Player Security Bulletin Updates, see the Adobe website
(http://www.adobe.com/support/security/index.html#flashplayer).
•
Pop-up windows
HP Virtual Connect Manager 58
Pop-up windows must be enabled for certain features to function correctly. Check the browser settings
to make sure pop-up blockers are not enabled before running the application.
•
Cookies
Cookies must be enabled for certain features to function correctly. Check your browser settings to make
sure cookies are enabled before running the application.
•
TLS 1.2
When managing Virtual Connect domains in FIPS mode, TLSv1.2 must be enabled in the browser.
The following browser versions support TLS 1.2 natively:
o
Internet Explorer 11 and above
o
Mozilla Firefox 27 and above
The following browser versions disable TLS 1.2 by default. Be sure to enable TLS 1.2 before attempting
to access the VCM GUI:
o
Internet Explorer 8, 9, and 10
o
Mozilla Firefox 24, 25, and 26
To enable TLS 1.2 for Internet Explorer:
a. Click Tools, and then select Internet Options.
b. Select the Advanced tab.
c.
Scroll down to the Security section, and then check the Use TLS 1.2 checkbox.
To enable TLS 1.2 for Mozilla Firefox:
a. Enter about:config in the URL address bar.
If prompted, read the warning statement.
b. Search for the TLS preference setting. Enter the following string into the preference search bar:
security.tls.version.max
c.
Set the value to 3.
Virtual Connect and Insight Control Server
Deployment
If you plan on using VC-assigned MAC addresses and WWNs and are also working with server software
that will be licensed by MAC addresses or WWNs, assign server profiles before deploying an image
through HP Insight Control Server Deployment or attaching the license.
Always apply relevant licenses that are dependent on MAC addresses after the server profiles are assigned
so that the licenses are not lost due to a change in MAC address.
IMPORTANT: If you plan to use Insight Control Server Deployment for RedHat Linux installation
and also plan to use User- or HP-defined MAC addresses, you must import the enclosure and
assign profiles before running Insight Control Server Deployment.
"Rip and replace" is not supported in a Virtual Connect environment.
For more information on HP Insight Control Server Deployment, see the HP website
(http://www.hp.com/servers/rdp).
HP Virtual Connect Manager 59
Accessing HP Virtual Connect Manager
Access to VCM occurs over the same Ethernet connection used to access the enclosure Onboard
Administrator and server blade iLO connections.
Access VCM in one of the following ways:
•
If the management network uses dynamic DNS, locate the Default Network Settings label on the
primary VC-Enet module, and then type the DNS name into the address field of the web browser.
If the management network does not use dynamic DNS, use the Onboard Administrator to access VCM.
•
Log on to the enclosure Onboard Administrator. From the rack overview screen, select the Virtual
Connect Manager link from the left navigation tree.
•
Log on to the enclosure Onboard Administrator. To display the Interconnect Bays summary screen,
select Interconnect Bays in the left navigation tree of the Onboard Administrator user interface. Select
the Management URL link for the primary VC-Enet module.
VCM typically operates on the primary VC-Enet module unless that module becomes unavailable,
causing a failover to the backup VC-Enet module. If you cannot connect to the primary VC-Enet module,
try connecting to the management URL for the backup VC-Enet module.
•
Access the VCM CLI remotely through an SSH session by connecting to the VC-Enet module
management IP address.
In a multi-enclosure VC domain, VCM runs on the primary module in the primary enclosure. If both the
primary and backup modules in the primary enclosure fail, are powered off, or are removed, VCM is not
accessible.
Command Line Interface overview
The VCM Command Line Interface can be used as an alternative method for administering the VCM. Using
the CLI can be useful in the following scenarios:
HP Virtual Connect Manager 60
•
You can develop tools that utilize VCM functions for data collection and for executing provisioning and
configuration tasks.
•
When no browser is available or you prefer to use a command line interface, you can access
management data and perform configuration tasks.
•
You can batch commands using script files. These script files can be run manually or scheduled to run
automatically.
For more information, see the HP Virtual Connect Manager Command Line Interface for c-Class BladeSystem
User Guide on HP website (http://www.hp.com/go/vc/manuals).
Logging on to the HP Virtual Connect Manager GUI
Log on using the user name (Administrator) and password.
You can optionally specify the authentication method or VCM role at log on:
•
•
To specify the authentication method (local, ldap, radius, tacacs), enter the authentication method
followed by a colon before the user name. For example, ldap:user1.
To specify the VCM role (domain, network, server, storage), enter the role followed by a colon before
the user name. For example, network:user1.
For more information on authentication methods and VCM roles, see the information about Virtual Connect
users and roles in the HP Virtual Connect for c-Class BladeSystem User Guide on the HP website
(http://www.hp.com/go/vc/manuals).
If the default password for the Administrator user has been changed and needs to be restored, see "Resetting
the Administrator password and DNS settings (on page 128)."
Logon problems might be caused by the following:
•
You have recently upgraded the VCM firmware. You might have to clear the browser cache before
attempting to log on again.
HP Virtual Connect Manager 61
•
The information is not being entered correctly. User names and passwords are case-sensitive.
•
The account being entered is not an account for VCM.
•
The account being entered has been deleted, disabled, or locked out.
•
The password for the account needs to be changed.
•
There is no connection to the primary VC-Enet module running VCM.
•
VCM is undergoing a failover or recovery.
•
The attempted IP sign-in address is not valid for the specified account.
•
The attempted IP sign-in address is for a VC-Enet module not running the primary VCM.
•
The browser settings are incorrect. See "Configuring browser support (on page 58)."
•
You have entered an invalid role or authentication service name.
•
Authentication service is disabled, is not correctly configured, or is not up in the server.
About HP Virtual Connect Manager
To view detailed product information, select About HP Virtual Connect Manager from the Help pull-down
menu.
Reset Virtual Connect Manager
You must have domain privileges to reset VCM. In a multi-enclosure environment, the VC-Enet modules in
bays 1 and 2 of the local enclosure host VCM. With VC 3.10 and higher, the primary modules can be in
bays other than 1 and 2.
To reset VCM running on the primary VC-Enet module, select Reset Virtual Connect Manager from the Tools
pull-down menu. The Reset Virtual Connect Manager screen appears.
•
If the Force Failover checkbox is selected and a VC-Enet module is available in the alternate
interconnect bay, the GUI is redirected to the alternate VC-Enet module for log on after the VCM has
restarted. Reset times depend on the size and complexity of the VC domain configuration.
•
If the Force Failover checkbox is not selected or a VC-Enet module is not available in the alternate
interconnect bay, the VCM restarts on the current VC-Enet module, and you are presented the logon
screen for the current VC-Enet module after VCM restarts. Reset times depend on the size and
complexity of the VC domain configuration.
When resetting the VC-Enet module, VCM is temporarily unavailable. If failover is specified and a backup
VC-Enet module is available, you are logged off and redirected to the backup VC-Enet module IP address.
Recovering remote enclosures
The credentials of the remote enclosure must be restored in the following situations:
•
A previously saved configuration file is restored.
•
The Onboard Administrator is reset to factory defaults.
•
The Onboard Administrator associated with the remote enclosure is replaced.
HP Virtual Connect Manager 62
If the IP address of the OA in the remote enclosure is lost, the remote enclosure is also marked as NO-COMM.
If IP connectivity is lost, credential recovery is not required. The enclosure automatically recovers after
connectivity is returned.
Running the setup wizards
HP Virtual Connect Domain Setup Wizard
A Virtual Connect domain consists of an enclosure and a set of associated modules and server blades that
are managed together by a single instance of the VCM. The Virtual Connect domain contains specified
networks, server profiles, and user accounts that simplify the setup and administration of server connections.
Establishing a Virtual Connect domain enables you to upgrade, replace, or move servers within your
enclosures without changes being visible to the external LAN/SAN environments.
Beginning with VC 4.10, an auto-deployment feature allows for the configuration of a VC domain from a
centralized location using DHCP and TFTP to access the configuration script. Auto-deployment is supported
only for single-enclosure domains. For more information on auto-deployment, see the HP Virtual Connect for
c-Class BladeSystem User Guide on the HP website (http://www.hp.com/go/vc/manuals).
Plan your interconnect module usage carefully before running the Virtual Connect Domain Setup Wizard.
After an interconnect bay is configured for use with a VC module, it remains configured for that module type
until the module is removed or the overall VC domain is deleted. Virtual Connect reports failures for any VC
module that is removed from the domain.
Before getting started, perform the following tasks:
•
Verify that the HP Onboard Administrator is running the latest firmware. HP recommends using the latest
version available. Using IPv6 requires OA 4.01 or higher.
•
Note the following information from the Default Network Settings label attached to the primary module:
•
o
DNS name
o
User name
o
Password
Connect any Ethernet module stacking cables ("Recommended stacking connections" on page 24).
After logging in for the first time, the Virtual Connect Domain Setup Wizard appears. This wizard walks you
through the following tasks:
•
Importing the enclosure (creating the domain)
•
Naming the domain
•
Administrating local users
HP Virtual Connect Manager 63
If the wizard is canceled before an enclosure is imported, you are returned to the Virtual Connect login page.
An enclosure must be imported to proceed.
Local Enclosure
To communicate with other VC modules and server blades, VCM requires the logon credentials for the local
Onboard Administrator.
IMPORTANT: An Onboard Administrator user name and password with full administrative
privileges for the selected enclosure is required.
Enter the user name and password for the enclosure Onboard Administrator. The local enclosure is detected
and selected automatically. If an error appears, it indicates that an invalid Onboard Administrator user name
and password, or one without sufficient privileges, might have been used.
After you import the remote enclosure, the OA IP address must not change. You must always assign a static
IP address or configure it appropriately through your DHCP server.
HP Virtual Connect Manager 64
VCM creates a local user named "vcmuser" on the OA module. Do not modify the credentials for this user.
Do not change the "local users" authentication setting for the OA module.
Enclosure Import/Recovery
After VCM has successfully established contact with the Onboard Administrator, you can create a Virtual
Connect domain by importing the enclosure or by restoring a previously created Virtual Connect domain
from a saved configuration file.
If you plan to use double density server blades, select the "Enable double dense server support (Restricts
single dense server support)" checkbox to display server device bays as double density slots.
This option should only be selected if double-dense servers will be in use. Single-dense servers do not have
access to I/O bays 7 and 8 when this option is selected.
NOTE: This option cannot be modified. After the enclosure is imported, select the Display single
dense device bays checkbox on the Domain Settings (Configuration) screen to display server
device bays as single density slots again.
For more information, see "Using double-dense server blades (on page 68)."
Select the appropriate method for creating the Virtual Connect domain.
•
To create the Virtual Connect domain by importing an enclosure, select the "Create a new Virtual
Connect domain by importing this enclosure" radio button, and then click Next. This process can take
several minutes as VCM establishes contact with each module in the enclosure and identifies its
capabilities.
HP Virtual Connect Manager 65
CAUTION: Restoring a Virtual Connect domain configuration from a backup file that was
created on another Virtual Connect domain is not supported and can cause serious faults within
this and other Virtual Connect Domains within the environment. The restore selection and
configuration files should only be used to restore the same previously existing domain.
•
To restore a domain using an existing configuration file, select the "Restore a Virtual Connect domain
using an externally-saved configuration file" radio button, and then click Next.
HP Virtual Connect Manager 66
Enclosure Import
After making the selection to create a new Virtual Connect domain by importing the enclosure on the
Enclosure Import/Recovery screen, the Import Status screen appears and provides information about
whether the import was successful. If the import is not successful, error information is displayed.
Importing additional enclosures
To import additional enclosures using the Domain Setup Wizard after the initial enclosure has been
imported:
1.
Select Tools > Domain Setup Wizard.
2.
On the Enclosure Import Recovery screen, click Find Enclosure.
3.
Click Find Enclosure to find additional enclosures.
4.
Enter the OA IP address, user name, and password.
5.
Select the checkbox next to the enclosures to import.
6.
Click Next. The Import status screen appears so that you can verify a successful import.
To import additional enclosures using the Domain Settings screen:
1.
Click the Domain Settings link on the Virtual Connect Home screen.
2.
Click the Domain Enclosures tab.
3.
Click Add.
4.
Enter the appropriate OA information, and then click OK.
5.
Select the checkbox next to the enclosure to import.
HP Virtual Connect Manager 67
6.
Click Import.
Using double-dense server blades
Virtual Connect Manager supports the use of double-dense server blades, enabling support for up to 32
device bays in a single c7000 enclosure. This support also provides 32 new device bays (1A-16A and
1B-16B) for profile assignment. On a c3000 enclosure, this feature supports 8 additional or 16 total device
bays. (1A-8A and 1B-8B)
The two physical servers A and B in a double-dense server blade correspond to the left and the right sides of
the device bay in c7000 enclosures, or the top and bottom of the device bay in c3000 enclosures. Servers
A and B have independent iLO, power, presence, and status capabilities.
In c7000 enclosures, Bays 1A-16A are associated with the left sides of the double-dense server blades
seated in the half-height bays 1-16. Bays 1B-16B are associated with the right sides of the double-dense
server blades seated in the half-height bays 1-16. In c3000 enclosures, Bays 1A-8A are associated with the
top of the double-dense server blades seated in the half-height bays 1-8. Bays 1B-8B are associated with the
bottom of the double-dense server blades seated in the half-height bays 1-8.
Enclosure recovery
If restoring a Virtual Connect domain using an externally saved configuration file, click Browse and locate the
saved configuration file.
CAUTION: Restoring a Virtual Connect domain configuration from a backup file that was
created on another Virtual Connect domain is not supported and can cause serious faults within
this and other Virtual Connect Domains within the environment. The restore selection and
configuration files should only be used to restore the same previously existing domain.
If the configuration file was originally created on an enclosure with a different serial number, the Ignore
enclosure serial number in restored configuration file checkbox must be selected to allow it to be used in a
new enclosure. Click Next to continue restoring the enclosure. At the end of the restoration, the browser
returns to the login screen. After the domain is restored, one of the local user accounts from the original
Virtual Connect domain must be used to login.
HP Virtual Connect Manager 68
When restoring from the configuration file, remote enclosure credentials are lost. See "Recovering remote
enclosures (on page 62)."
General Settings
The Virtual Connect domain name should be unique within the data center, and can be up to 31 characters
without spaces or special characters.
The Domain Setup Wizard automatically assigns a domain name (enclosurename_vc_domain). This name
can be changed when running the setup wizard, or at any time from the Domain Settings (Configuration)
screen.
HP Virtual Connect Manager 69
Local Users
The first time this screen appears, the Administrator account, which has all administrative user role
permissions, might be the only user listed. The Administrator account cannot be deleted or have domain user
role permissions removed. However, the Administrator password can be changed, and the network, server,
and storage user role permissions can be removed. The default Administrator password is identified on the
Default Network Settings label on the primary VC module.
To reset the Administrator password to the factory default, see "Resetting the Administrator password and
DNS settings (on page 128)." Resetting the Administrator password using the system maintenance switch
does not delete the VC domain, if configured. The password and DNS name of the module is reset to match
the information included on the Default Network Settings label on the module.
The following tasks can be performed on this screen:
•
To create a new local user account, click Add. The Add Local User screen appears.
•
To edit attributes of a defined local account, click the Edit link in the user row.
•
To delete a user account, select the checkbox next to the user name, and then click Delete.
TIP: You can also highlight a user, right-click, and then select Add, Delete, or Edit from the
pull-down menu.
•
To enable strong passwords, select the Require Strong Passwords checkbox. Use the up and down
arrows to select a password length between 3 and 40 characters. The default password length for a
newly created domain is 8 characters. With strong passwords enabled, passwords must also contain at
least one character from three of the following four categories:
o
Upper-case character
o
Lower-case character
o
Numeric character
o
Non-alphanumeric character
HP Virtual Connect Manager 70
Click Apply to save your changes.
•
To set a session timeout period, enter a number between 10 and 1440 in the Session Timeout box. To
disable a session timeout period, enter 0. Click Apply to save your changes.
Any change in the timeout value affects all open sessions and is applied to new sessions.
•
To edit the delete confirmation preference, select or clear Auto Populate Name During Delete
Confirmation, and then click Apply. VCM displays confirmation dialog boxes when deleting objects
such as server profiles, networks, and so on. These dialog boxes require you to enter the name of the
item you want to delete and, in some cases, you must also enter the word "delete." If you enable the
Auto Populate Name During Delete option, the confirmation dialog boxes appear with the required
information automatically populated, enabling you to simply click OK to proceed with the deletion. This
is a domain-wide setting.
•
To enable local users, select the Enable Local Users checkbox. To disable local users, clear the Enable
Local Users checkbox. Click Apply to save your changes. You cannot disable local users if you are
logged in as a local user. Log in as an LDAP, TACACS, or RADIUS authenticated user with domain
privileges to disable local users.
•
To select the Primary Remote Authentication Method, select an option from the Primary Remote
Authentication Method list. Click Apply to save your changes. The Primary Remote Authentication
Method is the primary authentication mechanism that triggers the re-enablement of local user
authentication (if it was disabled) if the remote authentication servers are found to be unavailable
during login by a remote VC user. Valid values include NONE, LDAP, RADIUS, and TACACS. The
default value is NONE.
HP Virtual Connect Manager 71
User Settings
Observe the following user settings guidelines:
•
Username is a required field.
•
The Username field must contain an alpha-numeric value with 1 to 31 characters.
•
The Password field must contain an alpha-numeric value with 3 to 40 characters. The default password
length is 8 characters.
•
If strong passwords are enabled, the password must contain the administrator-designated number of
characters and at least one character from three of the following four categories:
o
Upper-case character
o
Lower-case character
o
Numeric character
o
Non-alphanumeric character
•
The Full Name field can contain a value with a maximum value of 63 characters.
•
The Contact field can contain a value with a maximum value of 127 characters.
Up to 32 local user accounts can be created. Each account can be set up to have a combination of up to four
access roles: Domain, Network, Server, Storage. When a role is selected, the operations for that role are
listed with a checkmark.
The operations assigned to each role can be edited on the Role Management (Role Operations) screen.
HP Virtual Connect Manager 72
Finish domain wizard
Click Finish to complete this wizard, and then run the Network Setup Wizard ("HP Virtual Connect Network
Setup Wizard" on page 73) to define the Ethernet networks that will be available within the Virtual Connect
domain.
Deselect the Start the Network Setup Wizard checkbox, and then click Finish to go to the Home page without
running additional setup wizards.
HP Virtual Connect Network Setup Wizard
This wizard establishes external Ethernet network connectivity for the HP BladeSystem c-Class enclosure using
HP Virtual Connect. A user account with network privileges is required to perform these operations. Use this
wizard to do the following:
•
Identify the MAC addresses to be used on the servers deployed within this Virtual Connect domain.
•
Choose the method of handling VLAN tagged packets from servers.
•
Configure multiple networks link speed settings.
•
Set up connections from the HP c-Class enclosure to the external Ethernet networks.
These connections can be uplinks dedicated to a specific Ethernet network or shared uplinks that carry
multiple Ethernet networks with the use of VLAN tags.
•
Define external network connections with shared uplinks that carry multiple Ethernet networks or FCoE
networks
Be sure to connect any Ethernet module stacking cables before running the setup wizard.
HP Virtual Connect Manager 73
IMPORTANT: For a Virtual Connect environment to operate properly, all HP Virtual Connect
Ethernet modules within the Virtual Connect domain must be interconnected with stacking links.
HP strongly recommends that redundancy be maintained in stacking links to ensure continued
connectivity of servers to the external networks.
For more information, see “Supported configurations (on page 16)" and “Recommended stacking
connections (on page 24)."
NOTE: Virtual Connect does not support stacking for FC modules, so each VC-FC module
requires uplink connections to the external FC SAN environment.
To initiate this wizard, click the Network Setup Wizard link on the homepage, or select Network Setup
Wizard from the Tools pull-down menu. You must have network role permissions to access the Network Setup
Wizard.
MAC Address Settings
At this point in the wizard, you are asked to select the type of Ethernet MAC addresses to be used on the
server blades within the enclosure. Choose either the server factory default Ethernet MAC address that came
with the server or the Ethernet MAC addresses assigned by Virtual Connect. Be sure to fully understand the
following information before making this selection.
IMPORTANT: Configuring Virtual Connect to assign server blade MAC addresses requires
careful planning to ensure that the configured range of MAC addresses is used once within the
environment. Duplicate MAC addresses on an Ethernet network can result in a server network
outage.
Each server blade Ethernet NIC ships with a factory default MAC address. The MAC address is a 48-bit
number that uniquely identifies the Ethernet interface to other devices on the network. While the hardware
ships with default MAC addresses, Virtual Connect can assign MAC addresses that override the factory
default MAC addresses while the server remains in that Virtual Connect enclosure.
HP Virtual Connect Manager 74
Always establish control processes to ensure that a unique MAC address range is used in each Virtual
Connect domain in the environment. Reusing address ranges could result in server network outages caused
by multiple servers having the same MAC addresses.
If using Virtual Connect assigned MAC addresses, the following notes apply:
•
Virtual Connect automatically assigns two MAC addresses to each VC-Enet connection in the server
profile, a primary address for the Ethernet NIC, and an iSCSI MAC address for use by multifunction
gigabit server adapters, such as the HP NC373m PCI Express Dual Port Multifunction Gigabit Server
Adapter. Only the primary MAC address is used by standard (not multifunction) Ethernet devices.
•
If a server blade is moved from a Virtual Connect managed enclosure to a non-Virtual Connect
enclosure, the local MAC addresses on that server blade are automatically returned to the original
factory defaults.
•
If a server blade is removed from a bay within a Virtual Connect domain and installed in another bay
in the same Virtual Connect domain or in a bay in a different domain, it is assigned the new set of
addresses appropriate for that server location.
•
When FlexFabric adapters are in use, Virtual Connect assigns a MAC address to each FCoE connection
in the server profile.
Assigned MAC addresses
The MAC address range used by the Virtual Connect domain must be unique within the environment. HP
provides a set of pre-defined ranges that are for use by VCM and do not conflict with server factory default
MAC addresses.
When using the HP-defined MAC address ranges, be sure that each range is used only once within the
environment.
HP Virtual Connect Manager 75
Select the type and range of MAC address, and then click Next.
Selecting VC-assigned MAC address ranges
When using VC-assigned MAC addresses, you can choose between using an HP pre-defined MAC address
range or using a user-defined MAC address range.
•
HP pre-defined MAC address range (recommended). These pre-defined ranges are reserved and are
not the factory default on any hardware. There are 64 ranges of 1024 unique addresses to choose
from. Be sure to use each range only once within a data center.
1024 unique addresses might not be enough for a large configuration (multiple enclosures with many
Flex-10 NICs). If you plan a domain of this type, determine the number of MAC addresses you are likely
to use, and then select an option that provides the domain with sufficient MAC addresses.
•
User-defined MAC address range. To avoid potential conflict with other hardware MAC addresses in
the environment, consider using a subrange of MAC addresses reserved by the IEEE for
locally-administered MAC addresses. Ensure that the range does not conflict with any Ethernet device
already deployed within the enterprise.
IMPORTANT: If you plan to use Insight Control Server Deployment for RedHat Linux installation
and also plan to use User- or HP-defined MAC addresses, you must import the enclosure and
assign profiles before running Insight Control Server Deployment.
HP Virtual Connect Manager 76
NOTE: After any server profiles are deployed using a selected MAC address range, that range
cannot be changed until all server profiles are deleted.
Select the type and range of MAC address, and then click Next.
Server VLAN Tag Settings
VLAN tunneling support
You can tunnel VLAN tags and map VLAN tags in the same domain. As of VC 3.30, tunneling and mapping
is configured at the network level, not at the domain level. Server VLAN tunneling is supported only on
networks with dedicated uplinks and cannot be used with shared uplink sets.
Server VLAN tagging support
When the 'Force server connections to use same VLAN mappings as shared uplink sets' check box is
selected, server ports connected to multiple VC Ethernet networks are forced to use the same VLAN mappings
as those used for the corresponding shared uplink sets. This action forces all server connections mapped to
multiple networks to be linked to a shared uplink set. Server administrators cannot override this selection
when creating or editing a profile. When this check box is selected, server network connections can only be
selected from a single shared uplink set.
When the 'Force server connections to use same VLAN mappings as shared uplink sets' check box is not
selected, server network connections can be selected from any VC Ethernet network and the external VLAN
ID mappings can be manually edited. However, administrators must ensure that no server connection VLAN
ID conflict exists.
The 'Force server connections to use the same VLAN mappings as shared uplink sets' check box can be
selected if no server profile connections are assigned to multiple networks that are not linked to a shared
uplink set.
VLAN capacity
When the domain is configured with the Expanded VLAN capacity mode, observe the following:
•
1,000 networks can be in-use at any time.
An In-use network is defined as either:
HP Virtual Connect Manager 77
o
An Ethernet network that is assigned to a profile or an sFlow configuration
o
An FCoE network that is associated with a shared uplink set
VCEM enforces consistent in-use definitions across all domains in each domain group. If a domain
is in maintenance mode and changes are made which would increase the number of in-use
networks beyond 1000 for any domain in the domain group, the complete maintenance operation
fails, and the domain stays in maintenance mode.
HP recommends limiting the total number of FCoE VLANs on any individual VC ENET module to 32.
•
8,192 Ethernet and FCoE VLANs can be defined per domain.
•
4,094 Ethernet and FCoE VLANs can be defined per shared uplink set.
Shared uplink sets support a maximum of 32 FCoE networks.
•
162 VLANs can be defined per physical server port.
For example, if you configure 150 VLAN mappings to FlexNIC-a, then only 12 VLANs can be
configured for the remaining FlexNICs (FlexNIC-b, FlexNIC-c, and FlexNIC-d).
o
Duplicate VLANs cannot be configured on the same physical port.
o
Do not map more than 162 VLANs to one physical server port. If you exceed the 162 VLAN limit,
the physical server port is disabled and the four server connections are marked as failed.
When the domain is configured with the Legacy VLAN Capacity mode, observe the following:
•
The option to select Legacy VLAN Capacity mode is disabled when creating new domains with VC
firmware 3.70 or higher. Reverting from Expanded VLAN Capacity mode back to Legacy VLAN
Capacity mode is not allowed.
•
To maintain compatibility for VC domains configured with Legacy VLAN Capacity mode and
upgrading firmware from VC 3.30 to VC3.70 or higher, the VCM CLI maintains the functionality of the
Legacy VLAN capacity setting. This allows the use of existing scripts that configure the VLAN capacity
mode.
Multiple Networks Link Speed Settings
When using mapped VLAN tags (multiple networks over a single link), these settings are used for the overall
link speed control. Select the checkbox next to each item to set the value.
These settings affect only newly created profiles.
Versions of VC prior to v4.01 used the "preferred speed" to control bandwidth allocation. When existing
profiles are upgraded to VC v4.01 or later, the "maximum speed" from the network is set automatically on
the connection. If no maximum speed was configured prior to the upgrade, then the maximum speed is 20
Gb for Ethernet connections. The 20Gb maximum speed is dependent on 20Gb NICs and the HP VC
FlexFabric-20/40 F8 Module being present in the domain. The pre-4.01 behavior can be retained by setting
"maximum speed" to the same value as "preferred speed". When the maximum speed and preferred speed
for a network are set to the same bandwidth, then the profile connection bandwidth does not exceed the
custom speed set on the connection.
IMPORTANT: Depending on the NIC firmware versions in use, you might need to upgrade the
NIC firmware for these speed enforcement settings to work correctly.
To change these settings:
1.
Click the selection box, and then select a setting (100Mb to 20Gb):
HP Virtual Connect Manager 78
o
Set preferred connection speed. This value is the default speed for server profile connections
mapped to this network. The server administrator can increase or decrease this setting on an
individual profile connection. This setting is used for the minimum bandwidth.
o
Set maximum connection speed. This value is the maximum speed for server profile connections
mapped to this network. This setting limits the maximum port speed from the server to the network
connection associated with the multiple networks. Maximum bandwidth is determined by the
maximum connection speed of the network. All multiple networks share the same maximum
connection speed.
The availability of the 20Gb setting is dependent on 20Gb NICs and HP VC FlexFabric-20/40 F8
Modules being present in the domain.
2.
Click Apply.
Virtual Connect can control link speed for FlexNICs only when they are connected to an HP Virtual Connect
Enet Module. Virtual Connect cannot control the link speed of traditional NICs.
IMPORTANT: Each FlexNIC and FlexHBA is recognized by the server as a PCIe physical function
device with adjustable speeds from 100 Mb to 10 Gb in 100 Mb increments when connected to
an NC553i/m 10Gb 2-port FlexFabric FlexFabric Adapter or any Flex-10 NIC. For NC551i/m
Dual Port FlexFabric 20 Gb FlexFabric Adapters, the range is limited to 1 Gb to 20 Gb in 100 Mb
increments.
For more information on FlexNICs, see the HP Virtual Connect for c-Class BladeSystem User Guide on the HP
website (http://www.hp.com/go/vc/manuals).
Select Network Connection Type
To begin, select one of the following external network connections:
•
Connection with uplink(s) dedicated to a single network ("Define Single Network" on page 80)
Select this option to define a network within the Virtual Connect environment and identify any module
uplink ports used to connect to that network in the data center. Internal-only networks (without external
uplinks) can also be defined.
These single networks pass through any VLAN tags added by the server or added externally.
•
Connection with uplink(s) carrying multiple Ethernet networks and/or FCoE networks (using VLAN
tagging) ("Define Shared Uplink Set Connection" on page 83)
Select this option to define multiple networks, FCoE networks, or both that all share a common set of
module uplink ports within the Virtual Connect environment. Network traffic from each network within
the Virtual Connect environment receives a VLAN tag as it exits on a shared uplink port. Virtual Connect
uses the VLAN tag on incoming network traffic to place it on the appropriate internal network. Ethernet
VLAN tags are added on egress and stripped on ingress.
Avoid using this type of network connection when the server inserts VLAN tags.
One network can be designated as a native VLAN, causing all untagged incoming Ethernet packets to
be placed on this network. For more information, see "Shared uplink sets and VLAN tagging" in the user
guide.
After each network is defined, you have the option to define additional networks or finish the wizard.
HP Virtual Connect Manager 79
To determine the types of network connections to use, see "Connecting Virtual Connect Ethernet module
uplinks (on page 47)."
Define Single Network
HP Virtual Connect Manager 80
To define a network:
1.
Enter a name for the network that will be easily understood and recognized by the server administrators
defining and deploying server profiles. The network name can be up to 64 characters in length (no
spaces).
2.
To add a color to the network, select a color from the Color pull-down menu. The network color is used
as a visual identifier for the network within VCM.
3.
To add labels to the network, type a label in the Labels field, and then press Enter. Labels are used as
text-based identifiers for the network within VCM. Each label can contain up to 24 characters,
excluding spaces. Each network can have up to 16 labels.
4.
To enable Smart Link, select the Smart Link checkbox.
The checkbox is not available until an uplink is added to the network.
5.
To designate as a private network, select the Private Network checkbox.
6.
To enable VLAN tunneling, select the Enable VLAN Tunneling checkbox.
7.
To set a custom value for the preferred link connection speed or maximum link connection speed, select
the Advanced Network Settings checkbox. For more information, see "Advanced Network Settings (on
page 81)."
8.
Set the connection mode to Auto or Failover.
9.
If the connection mode is set to Auto, set the length of the LACP Timer.
10.
Select the specific VC-Enet module external uplink ports that will connect the network to the data center.
The available external ports are listed in the multi-level Add Port selector. Each port is labeled as linked
or not linked. This status refers to whether or not a current connection to an external switch exists.
If the network will be local to the servers within the VC domain (enclosure), then no uplinks need to be
selected.
To delete a port, click the Delete link in the Action column of the row to be deleted.
11.
In the Network Access Groups field, begin typing the name of a Network Access Group that should
include this network. When the Network Access Group name appears, select the name.
12.
Click Create Network.
For more information on defining networks, see the HP Virtual Connect for c-Class BladeSystem User Guide
on the HP website (http://www.hp.com/go/vc/manuals).
Advanced Network Settings
These settings affect only newly created profiles.
Versions of VC prior to v4.01 used the "preferred speed" to control bandwidth allocation. When existing
profiles are upgraded to VC v4.01 or later, the "maximum speed" from the network is set automatically on
the connection. If no maximum speed was configured prior to the upgrade, then the maximum speed is 20
Gb for Ethernet connections. The 20Gb maximum speed is dependent on 20Gb NICs and the HP VC
FlexFabric-20/40 F8 Module being present in the domain. The pre-4.01 behavior can be retained by setting
"maximum speed" to the same value as "preferred speed". When the maximum speed and preferred speed
for a network are set to the same bandwidth, then the profile connection bandwidth does not exceed the
custom speed set on the connection.
IMPORTANT: Depending on the NIC firmware versions in use, you might need to upgrade the
NIC firmware for these speed enforcement settings to work correctly.
HP Virtual Connect Manager 81
To change these settings:
1.
Click the selection box, and then select a setting (100Mb to 20Gb):
o
Set preferred connection speed. This value is the default speed for server profile connections
mapped to this network. The server administrator can increase or decrease this setting on an
individual profile connection. This setting is used for the minimum bandwidth.
o
Set maximum connection speed. This value is the maximum speed for server profile connections
mapped to this network. This setting limits the maximum port speed from the server to the network
connection associated with the multiple networks. Maximum bandwidth is determined by the
maximum connection speed of the network. All multiple networks share the same maximum
connection speed.
The availability of the 20Gb setting is dependent on 20Gb NICs and HP VC FlexFabric-20/40 F8
Modules being present in the domain.
2.
Click Apply.
HP Virtual Connect Manager 82
Define Shared Uplink Set Connection
To define multiple networks that share a common set of external uplink ports:
1.
Enter an overall name for the set of shared uplinks (up to 64 characters, no spaces).
2.
Set the connection mode to Auto or Failover.
3.
If the connection mode is set to Auto, set the length of the LACP Timer.
4.
From the Add Port list, select the external uplink ports that will carry these networks.
To delete a port, click the Delete link in the Action column of the row to delete.
5.
Click Add to define an associated FCoE Network.
When associating an FCoE network, the shared uplink set must contain uplink ports from a single VC
module. In a multi-enclosure domain, the matching ports must be available in all enclosures in the
domain. For VC 4.10, only one FCoE network can be associated with a given shared uplink set. In VC
4.20 and later, up to 32 FCoE networks can be associated with a given shared uplink set.
a. Enter a network name.
b. Enter a VLAN identifier.
c.
To add a color to the network, select a color from the Color pull-down menu. The network color is
used as visual identifier for the network within VCM.
HP Virtual Connect Manager 83
d. To add labels to the network, type a label in the Labels field, and then press Enter. Labels are used
as text-based identifiers for the network within VCM. Each label can contain up to 24 characters,
excluding spaces. Each network can have up to 16 labels.
e. To set a custom value for the preferred link connection speed or maximum link speed, click
Advanced Network Settings. For more information, see "Advanced Network Settings (on page
81)."
f.
6.
Click Apply.
Click Add to define the name and VLAN identifier of each network to use these shared uplinks.
a. You can add a single associated network or multiple associated networks. Selecting multiple
associated networks enables you to enter a comma-separated list of individual VLANs and ranges
of VLANs that share a common name.
The name is composed of the prefix, VLAN ID, and suffix. An example name is provided after the
VLAN IDs are specified.
b. To add a color to the network, select a color from the Color pull-down menu. The network color is
used as visual identifier for the network within VCM.
c.
To add labels to the network, type a label in the Labels field, and then press Enter. Labels are used
as text-based identifiers for the network within VCM. Each label can contain up to 24 characters,
excluding spaces. Each network can have up to 16 labels.
d. To use native VLAN, select the Native check box. Only one VLAN can be designated as the native
VLAN.
e. To use Smart Link, select the Smart Link check box. The check box is not available until an uplink is
added to the shared uplink set.
f.
To designate the network as private, select the Private Network check box.
g. To set a custom value for the preferred link connection speed or maximum link speed, click
Advanced Network Settings. For more information, see "Advanced Network Settings (on page
81)."
h. Click Apply.
7.
To create the associated networks, click Create Shared Uplink Set.
To delete associated networks, select the check box for one or more networks, and then click Delete.
For more information on defining a new shared uplink set and VLAN tagging, see the HP Virtual Connect for
c-Class BladeSystem User Guide on the HP website (http://www.hp.com/go/vc/manuals).
HP Virtual Connect Manager 84
Add an Associated FCoE Network.
Add a single Associated Network.
HP Virtual Connect Manager 85
Add multiple Associated Networks.
Defined Network Connections
This summary screen displays the external connections for each defined network.
HP Virtual Connect Manager 86
For more information about the data displayed on this screen, see "Ethernet Networks (External Connections)
screen" in the user guide.
To define additional networks in the domain, click Create more networks.
To complete the Network Setup Wizard, click Done.
To view a filtered list of created networks, click Filter, select the criteria, and then click Go. To return to the full
list, click X.
Finish network wizard
When the Network Setup Wizard completes, external Fibre Channel connectivity can be configured (if
applicable) or server profiles can be defined and associated with server blades.
To establish external Fibre Channel connectivity:
1.
Be sure the Start the Fibre Channel Wizard checkbox is selected.
2.
Click Finish. The Fibre Channel Wizard Welcome screen is displayed.
To begin deploying server blades:
1.
Be sure the Start Fibre Channel Wizard checkbox is not selected.
2.
Click Finish.
3.
Select Define Server Profile from the homepage.
Additional network connections can be defined at any time by using one of the following methods:
•
Select the Define a Network link on the homepage.
•
Select the Define a Shared Uplink Set link on the homepage.
HP Virtual Connect Manager 87
Select Ethernet Network from the Define pull-down menu.
HP Virtual Connect Fibre Channel Setup Wizard
This wizard configures external Fibre Channel connectivity for the HP BladeSystem c-Class enclosure using
HP Virtual Connect. A user account with storage privileges is required to perform these operations. Use this
wizard to do the following:
•
Identify WWNs to be used on the server blades deployed within this Virtual Connect domain.
•
Define fabrics.
To initiate this wizard, click the Fibre Channel Wizard link on the homepage, or select Fibre Channel Setup
Wizard from the Tools pull-down menu. You must have storage privileges to access the Fibre Channel Setup
Wizard.
HP Virtual Connect Manager 88
WWN settings
At this point in the wizard, you are asked to select the type of FC WWNs to be used on the server blades
within the enclosure. You can choose to use the server factory default WWNs provided with the FC HBA
mezzanine card or to use FC WWNs assigned by Virtual Connect. Be sure to fully understand the following
information before making this selection.
Each server blade FC HBA mezzanine card ships with factory default port and node WWNs for each FC
HBA port. Each WWN is a 64-bit number that uniquely identifies the FC HBA port/node to other devices on
the network. While the hardware ships with default WWNs, Virtual Connect has the ability to assign WWNs
that override the factory default WWNs while the server remains in that Virtual Connect enclosure. When
configured to assign WWNs, Virtual Connect securely manages the WWNs by accessing the physical FC
HBA through the enclosure Onboard Administrator and the iLO interfaces on the individual server blades.
When assigning WWNs to FC HBA ports, Virtual Connect assigns both a port WWN and a node WWN.
Because the port WWN is typically used for configuring fabric zoning, it is the WWN displayed throughout
the Virtual Connect user interface. The assigned node WWN is always the same as the port WWN
incremented by one.
Virtual Connect assigns or migrates WWNs for server FC ports connected to HP Virtual Connect modules.
Virtual Connect also assigns WWNs to FC ports that are not connected to an I/O module because Virtual
Connect modules can be added later. Server FC ports connected to non-Virtual Connect modules retain the
server factory default WWNs.
Configuring Virtual Connect to assign WWNs in server blades maintains a consistent storage identity
(WWN) even when the underlying server hardware is changed. This method allows server blades to be
replaced without affecting the external Fibre Channel SAN administration.
CAUTION: To avoid storage networking issues and potential loss of data associated with
duplicate WWNs on a FC SAN fabric, plan carefully when allowing Virtual Connect to assign
server blade WWNs so that the configured range of WWNs is used only once within the
environment.
HP Virtual Connect Manager 89
Assigned WWNs
The WWN range used by the Virtual Connect domain must be unique within the environment. HP provides
a set of pre-defined ranges that are reserved for use by Virtual Connect and do not conflict with server factory
default WWNs.
When using the HP-defined WWN ranges, be sure that each range is used only once within the environment.
Select the type and range of WWNs, and then click Next.
HP Virtual Connect Manager 90
Define Fabric
To define a fabric, select the Define Fabric checkbox, and then click Next.
If you do not want to define a fabric at this time, select I do not want to create a Fabric, and then click Next.
Define SAN Fabric
To define the SAN fabric:
1.
Name the fabric. Do not use spaces.
HP Virtual Connect Manager 91
2.
Select the uplink ports to be used. Only uplinks on the same bay can be in the same SAN fabric.
3.
If the uplink ports selected are FlexFabric module ports, select the fabric type. Supported fabric types
are FabricAttach and DirectAttach.
o
Select FabricAttach if the FlexFabric module is connected using traditional SAN switches. For this
fabric type, the advanced settings appear, allowing you to change the login re-distribution and set
the preferred and maximum connection speed.
o
Select DirectAttach if the FlexFabric module is directly connected to a supported storage target.
Login re-distribution is not applicable for a DirectAttach fabric; however, advanced settings are
available for the preferred and maximum FCoE connection speed.
After a fabric is defined, its type cannot be changed. The default fabric type is FabricAttach.
4.
If you are linking to an HP VC FlexFabric module and the fabric type is FabricAttach, click Advanced to
set the login re-distribution. For more information, see "Advanced SAN Fabric Settings (on page 92)."
5.
Change the configuration speed, if preferred.
6.
Click Apply.
In FabricAttach mode, connect only HP VC 4Gb FC Module, HP VC 8Gb 24-Port FC Module, HP VC 8Gb
20-Port FC Module, HP VC FlexFabric-20/40 F8 Module, or HP VC FlexFabric 10Gb/24-port Module
uplinks to Fibre Channel switch ports that are NPIV-enabled. If using a Brocade FC switch, verify that NPIV
is enabled properly by using the portshow command. If NPIV is not enabled properly, you might need to
downgrade the Brocade switch firmware, and then upgrade the firmware again.
For VC 8Gb 24-Port FC Modules, if uplink port 8 is present in the VC SAN fabric definition, this port is treated
as the lowest-numbered port and receives server logins before any other uplink ports.
In DirectAttach mode, connect the FC-capable uplink ports of the HP VC FlexFabric module to target ports on
the 3PAR array controller node.
Advanced SAN Fabric Settings
Login Re-Distribution
When creating or editing a SAN fabric using HP VC FlexFabric Modules in a FabricAttach fabric, select the
Show Advanced Settings checkbox to select the login re-distribution:
•
Manual Login Re-Distribution—Default for all FC modules. You must initiate a Login Re-Distribution
request through the VC GUI or CLI interfaces. You might re-distribute logins if an uplink that was
previously down is now available, if you added an uplink to a fabric, or if the number of logins through
each available uplink has become unbalanced for any reason.
•
Automatic Login Re-Distribution—When selected, the VC FlexFabric module initiates Login
Re-Distribution automatically when the specified time interval expires. For more information about
setting the time interval, see "Fibre Channel Settings (Misc.) screen" in the user guide.
The automatic option is only available on FlexFabric modules in a FabricAttach fabric and enables you to
specify an interval, in seconds, for the length of time the previously offline links must be stable before the
module can re-distribute logins. Login re-distribution is not supported for DirectAttach fabrics.
FCoE Connection Speed
To change these settings, click the selection box, and then select a setting (100Mb to 8Gb):
•
Set a custom value for the Preferred FCoE Connection Speed. This value is the default speed for server
profile connections mapped to this fabric. The server administrator can override this setting on an
individual profile connection.
HP Virtual Connect Manager 92
Set a custom value for the Maximum FCoE Connection Speed. This value is the maximum speed for server
profile connections mapped to this fabric.
To see how logins are currently distributed on the VC-FC module, navigate to the Interconnect Bays Status
and Summary screen and select the desired VC-FC module. A new Uplink Port column is added to the Server
Ports section of the screen.
To see how logins are currently distributed on the VC FlexFabric module, navigate to the Interconnect Bays
Status and Summary screen and select the desired VC FlexFabric module. A new SAN Uplink Port column is
added to the Server Ports tab.
You can also see how logins are currently distributed on the VC-FC or FlexFabric modules by logging in to the
upstream FC SAN fabric switch.
Fabric summary
This screen lists the summary of fabrics that are created.
Select Create more fabrics to define additional fabrics, or Done if you have defined all available fabrics.
HP Virtual Connect Manager 93
Finish Fibre Channel wizard
When the Fibre Channel Setup Wizard completes, server profiles can be defined and associated with server
blades.
To begin deploying server blades:
1.
Be sure the Start the Server Profile Wizard check box is selected.
2.
Click Finish. The Server Profile Wizard Welcome screen appears.
The FC SAN configuration can be changed at any time by using one of the following methods:
•
Click WWN Settings under Fibre Channel Settings in the left navigation tree of the homepage.
•
Select Fibre Channel Settings from the Configure pull-down menu.
HP Virtual Connect Manager Server Profile Setup Wizard
This wizard enables you to setup and configure network/SAN connections for the server blades within the
enclosure.
Use the wizard to define a server profile template that identifies the server connectivity to use on server blades
within the enclosure. Then use the template to create and apply server profiles to up to 16 server blades
automatically. Once created, the individual server profiles can be edited independently.
Before beginning the server profile wizard, do the following:
•
Complete the Network Setup Wizard.
•
Complete the Fibre Channel Setup Wizard (if applicable).
•
Be sure that any server blades to be configured using this wizard are powered off.
HP Virtual Connect Manager 94
This wizard walks you through the following tasks:
•
Designate serial numbers (logical) (optional)
•
Define a server profile template
•
Assign server profiles
•
Name server profiles
•
Create server profiles
Serial Number Settings
Use this screen to assign serial numbers to server blades within the domain.
By configuring VCM to assign serial numbers, a profile can present a single serial number regardless of the
physical server. With these configuration values added to server profiles, software that is licensed to a
particular server, based on one or both of these values, can be migrated to new server hardware without
re-licensing the software for the new server hardware. This feature prevents you from having to reinstall serial
number sensitive software after a system recovery.
CAUTION: The use of Serial Number Settings might prevent the proper operation of software
designed to track servers by serial number or UUID. Do not enable this feature until you consider
and understand the impact to the entire software environment in which the servers operate. This
impact includes, but is not limited to, warranty service, asset tracking, server deployment, and
software licensing.
HP Virtual Connect Manager 95
For more information on serial number settings, see the HP Virtual Connect for c-Class BladeSystem User
Guide on the HP website (http://www.hp.com/go/vc/manuals).
Create Server Profile Definition
Use this screen to create a new server profile definition, which defines and configures Ethernet and Fibre
Channel connectivity for the server.
HP Virtual Connect Manager 96
For more information on defining a server profile and advanced profile settings, see the HP Virtual Connect
for c-Class BladeSystem User Guide on the HP website (http://www.hp.com/go/vc/manuals).
Server profile troubleshooting
In some cases, server profiles can be assigned to server blades when certain mismatches exist between the
server profile definition and the server blade. The following list summarizes Virtual Connect behavior under
these circumstances:
•
If the number of network connections in the profile is more than the number of physical Ethernet ports,
the profile is assigned. When you view the profile, the connections display a status of "Not mapped."
•
If a switch other than a Virtual Connect Ethernet switch is connected to any port in the profile, the profile
is assigned, but the MAC address is not changed on the NIC. The connections display a status of “Not
mapped” when your view the profile.
•
If the number of Fibre Channel connections in the profile is more than the number of physical Fibre
Channel HBA ports, the profile is assigned, but the connections display a status of “Not mapped” when
you view the profile.
•
If the number of iSCSI connections in the profile is more than the number of available iSCSI ports on the
server, the profile assignment succeeds, but the connections display a status of "Not mapped" when
you view the profile.
HP Virtual Connect Manager 97
•
If the number of FCoE connections in the profile is more than the number of available FCoE ports on the
server, the profile assignment succeeds, but the connections display a statue of "Not mapped" when
you view the profile.
VCM supports a maximum of 256 profiles within the domain.
IMPORTANT: Disabling a server port by entering the iLO Remote Console, rebooting the server,
and then using the F9 key to enter RBSU causes a "Profile pending" status for a server profile
when a VCM failover occurs.
IMPORTANT: Virtual Connect versions 4.30 and later no longer support first-generation HP
Integrity BL860c Server Blades and HP Integrity BL870c Server Blades. HP Integrity i2 and i4
model server blades are still supported.
Assign Server Profiles
Server profiles are created from the definition. When these server profiles are created, you can choose to
automatically assign them to device bays or to leave the server profiles unassigned.
When defining server profiles in a multi-enclosure configuration, profiles can be assigned to server bays in
any of the enclosures that have been added and imported into the domain.
When a profile is created and assigned to a multi-blade server, the profile is applied to all of the blades in
the multi-blade server. Be sure that the profile contains enough Ethernet and Fibre Channel connection entries
for all of the ports on all of the blades in the multi-blade server.
HP Virtual Connect Manager 98
•
Single enclosure domain
HP Virtual Connect Manager 99
•
Multi-enclosure domain
Name Server Profiles
The table displays the automatically generated names that will be assigned to the new server profiles. The
server profile name can be up to 64 characters in length (no spaces). Because the server profile can be
assigned to different locations, HP recommends that the name reflect the server function. For each enclosure,
a base name is provided. You can use this enclosure name to create names for the profiles assigned to the
enclosure. The individual profile names can be edited as needed. Be sure that the names are unique and
meaningful.
After reviewing the profiles to be created, click Create Profiles.
HP Virtual Connect Manager 100
•
Single enclosure domain
•
Multi-enclosure domain
Create Server Profiles
This screen provides confirmation of each profile that was created and successfully assigned (if applicable).
HP Virtual Connect Manager 101
Click Start Over to create additional profiles using the wizard. This option returns you to the appropriate step
for creating more profiles.
Click Finish if you are finished creating profiles at this time. This option launches the Virtual Connect Home
page.
If creation of a server profile failed, see "Server profile troubleshooting (on page 97)."
Verifying data center connections
After completing the cabling between the HP BladeSystem c-Class enclosure and the data center networks,
use the following techniques to verify that the network connections are operating properly:
•
Verify that all external connections are linked and operating at the right speed.
•
Review the Virtual Connect Manager Network status screens ("Verify network status using VC
Manager" on page 103).
•
Use port IDs to verify network connections.
•
Configure a server and verify network connectivity.
HP Virtual Connect Manager 102
Verify link and speed
To verify that all external ports connected to the data center are linked and are operating at the appropriate
speed:
1.
Verify that all VC-Enet and FlexFabric modules are powered on and functioning properly. The module
status LED should be green for all modules connected and configured in Virtual Connect for data center
use.
If the LED is not green, use the HP Onboard Administrator user interface to diagnose the problem and
verify that the module is powered on.
2.
Verify that all VC-FC modules are powered on and functioning properly. The module status LED should
be green for all modules connected and configured in Virtual Connect for data center use.
If the LED is not green, use the HP Onboard Administrator user interface to diagnose the problem and
verify that the module is powered on.
3.
Verify that the data center switches are powered on.
4.
Verify that each external port is linked and operating at the appropriate speed using link/speed activity
LEDs for that port.
If ports are not linked, verify that the cables being used are not defective, and verify that both ends of
the link are configured for the same speed/duplex settings. Both sides of the configuration must match
for the link to be established. For autonegotiation, both ports must be configured to run autonegotiation.
To use a forced speed, (for example, 100 Mb full-duplex), both ports must be configured to be the same
forced speed. Mismatched configuration can result in ports not linking up or not functioning properly.
VC-Enet and FlexFabric modules do not support half-duplex operations.
5.
Verify that the port status indicator (port number) of each configured external port is illuminated green,
assuming no port IDs are enabled. This status indicates that the port is actively configured as part of an
external connection.
Verify network status using VC Manager
VCM provides many status and summary screens that can be used to verify that the networks were defined
properly and mapped to the appropriate network.
One useful summary screen is the Ethernet Networks (Summary) screen. To access this screen, click the
Ethernet Networks link in the left navigation tree.
The following actions are available from this screen:
•
Identify the external ports associated with each Ethernet network.
•
View the current port status (link, speed) of each external port.
•
View the current active/standby state of each external port.
•
Access information about attached switches (if the external switch supports LLDP).
•
Highlight the port IDs for all external ports associated with a specific network.
HP Virtual Connect Manager 103
Component identification
HP Virtual Connect Flex-10 10Gb Ethernet Module
components and LEDs
HP Virtual Connect Flex-10 10Gb Ethernet Module components
Item
Description
1
Port X1 (10GBASE-CX4), multiplexed with item 4
2
USB 2.0 mini AB connector (covered)
3
Next button
4
Port X1 SFP+ connector*, multiplexed with item 1
5
Port X2 SFP+ connector*
6
Port X3 SFP+ connector*
7
Port X4 SFP+ connector*
8
Port X5 SFP+ connector*
9
Port X6 SFP+ connector*
10
Port X7 SFP+ connector*, multiplexed with internal 10Gb interface
cross-link
11
Port X8 SFP+ connector*, multiplexed with internal 10Gb interface
cross-link
12
Reset button (recessed)
*Supports 1000BASE-T-SFP, 1000BASE-SX-SFP, 10GBASE-LR SFP+, 10GBASE-SR SFP+, and 10GBASE-LRM SFP+
pluggable transceiver modules
Component identification 104
HP Virtual Connect Flex-10 10Gb Ethernet Module LEDs
Item
LED description
Status
1
Module locator (UID) Blue = Module ID is selected.
Off = Module ID is not selected.
2
Module status
Green = Normal operation
Amber = Degraded condition
Amber flashing = Fault condition
Off = Power off
3
X1 port status
(10GBASE-CX4)
Green = Port is configured and operating as
an uplink port connected to a data center
fabric.
Amber = Port is operating as a stacking link
interconnecting Virtual Connect modules.
Blue = Port locator (PID)
Off = Unconfigured
4
X1 link/port activity
Green = Link
Green flashing = Activity
Off = No link
5
X1-X6 link/port
activity
Green = 10G link
Green flashing = 10G activity
Amber = 1G link
Amber flashing = 1G activity
Off = No link
6
X7/X8 link/port
activity
Green = 10G link
Green flashing = 10G activity
Amber = 1G link
Amber flashing = 1G activity
Off = No link
7
X7/X8 shared port
activity
Green = Port is active.
Off = Port is inactive.
Component identification 105
Item
LED description
Status
8
X7/X8 port status
Green = Port is configured and operating as
an uplink port connected to a data center
fabric.
Amber = Port is operating as a stacking link
interconnecting Virtual Connect modules.
Blue = Port locator (PID)
Off = Unconfigured
9
X1/X6 port status
Green = Port is configured and operating as
an uplink port connected to a data center
fabric.
Amber = Port is operating as a stacking link
interconnecting Virtual Connect modules.
Blue = Port locator (PID)
Off = Unconfigured
10
X1 shared port
activity
Green = Port is active.
Off = Port is inactive.
Shared port operation
Port X1 (10BASE-CX4) and Port X1 (SFP+)
Port X1 (10BASE-CX4) is multiplexed with Port X1 (SFP+). Either the CX-4 port is active or the SFP+ port is
active, but not both. The triangle LED underneath each port indicates which port is active. The SFP+ port
always has precedence over the CX4 port.
•
•
If there is a module installed in the SFP+ port, the SFP+ port is the active port.
o
The LED under the SFP+ port is on.
o
The LED under the CX4 port is off.
If there is no module installed in the SFP+ port, the CX4 port is the active port.
o
The LED under the CX4 port is on.
o
The LED under the SFP+ port is off.
Port X7 and port X8
•
Port X7 (SFP+) and port X8 (SFP+) are each multiplexed with an internal 10Gb interface cross-link,
which is provided on the enclosure midplane between two horizontally adjacent VC modules to
establish stacking links. Either the port is active or the internal cross-link is active, but not both. The
triangle LEDs underneath ports X7 and X8 indicate whether the SFP+ port is active or the internal
cross-link is active. The SFP+ port always has precedence over the internal cross-link port. Port X7 is
shared with internal cross-link 1, and Port X8 is shared with internal cross-link 2.
•
If there is a module installed in the SFP+ port, the SFP+ port is the active port.
The LED under the SFP+ port is on.
•
If there is no module installed in the SFP+ port, and the port has not been configured as an uplink in a
VC Ethernet network, then the corresponding internal cross-link is the active port.
The LED under the SFP+ port is off.
•
If there is no module installed in the SFP+ port, and the port has been configured as an uplink in a VC
Ethernet network, then the SFP+ port is the active port.
The LED under the SFP+ port is on.
Component identification 106
HP Virtual Connect Flex-10 10Gb Ethernet Module system
maintenance switch
Function
Switch positions*
Default setting
OFF OFF OFF OFF (0000)
Password/DNS reset
FIPS mode
ON OFF OFF OFF (1000)
OFF OFF ON OFF (0010)
*Switch positions are from 1 to 4.
See the following sections for function procedures:
•
"Resetting the Administrator password and DNS settings (on page 128)"
•
"Virtual Connect FIPS mode of operation (on page 34)"
Component identification 107
HP Virtual Connect Flex-10/10D Module components
and LEDs
HP Virtual Connect Flex10/10D Module components
Ports X1 through X10 support Ethernet traffic only.
Item
Component
Description
1
For support purposes only
2
USB 2.0 mini AB connector
(covered)
Next button
For support purposes only
3
Port X1 SFP+ connector
1Gb or 10Gb Ethernet
4
Port X2 SFP+ connector
1Gb or 10Gb Ethernet
5
Port X3 SFP+ connector
1Gb or 10Gb Ethernet
6
Port X4 SFP+ connector
1Gb or 10Gb Ethernet
7
Port X5 SFP+ connector
1Gb or 10Gb Ethernet
8
Port X6 SFP+ connector
1Gb or 10Gb Ethernet
9
Port X7 SFP+ connector
1Gb or 10Gb Ethernet
10
Port X8 SFP+ connector
1Gb or 10Gb Ethernet
11
Port X9 SFP+ connector
1Gb or 10Gb Ethernet
12
Port X10 SFP+ connector
1Gb or 10Gb Ethernet
The connectors support 1000BASE-T SFP, 1000BASE-SX SFP, 10GBASE-LR SFP+, 10GBASE-SR SFP+, 10GBASE-LRM
SFP+, and 10GBASE-DAC SFP+ pluggable Ethernet transceiver modules. For more information, see the Virtual Connect
QuickSpecs on the HP website (http://www.hp.com/go/vc/manuals).
HP Virtual Connect Flex10/10D Module LEDs
Component identification 108
Item
LED description
1
Module locator (UID) Blue = Module ID is selected.
Off = Module ID is not selected.
Status
2
Module status
Green = Normal operation
Amber = Degraded condition
Amber flashing = Fault condition
Off = Power off
3
X1–X10 link/port
activity
Green = 10G link
Green flashing = 10G activity
Amber = 1G link
Amber flashing = 1G activity
Off = No link
4
X1–X10 port status
Green = Port is configured and operating as
an uplink port connected to a data center
fabric.
Amber = Port is operating as a stacking link
interconnecting Virtual Connect modules.
Blue = Port locator (PID)
Off = Unconfigured
Component identification 109
HP Virtual Connect Flex10/10D Module system maintenance
switch
Function
Switch positions*
Default setting
OFF OFF OFF OFF (0000)
Password/DNS reset
FIPS mode
ON OFF OFF OFF (1000)
OFF OFF ON OFF (0010)
*Switch positions are from 1 to 4.
See the following sections for function procedures:
•
"Resetting the Administrator password and DNS settings (on page 128)"
•
"Virtual Connect FIPS mode of operation (on page 34)"
Component identification 110
HP Virtual Connect FlexFabric-20/40 F8 Module
components and LEDs
HP Virtual Connect FlexFabric-20/40 F8 Module components
Ports Q1 through Q4 support Ethernet. Ports X1 through X8 support Ethernet and Fibre Channel traffic. Port
pairs X5/X6 and X7/X8 carry a single type of network traffic, either Ethernet or Fibre Channel.
Item
Description
Capable speed
1
Port Q1 QSFP+ connector*
10Gb, 40Gb or 4x10Gb
2
Port Q2 QSFP+ connector*
10Gb, 40Gb or 4x10Gb
3
Port Q3 QSFP+ connector*
10Gb, 40Gb or 4x10Gb
4
Port Q4 QSFP+ connector*
10Gb, 40Gb or 4x10Gb
5
Next button
Toggles port LED mode through
PID, L/A, FC and Ethernet.
See "Port LED modes when
toggled using the Next button
(on page 112)."
6
—
7
USB 2.0 mini AB connector
(covered)
Port X1 SFP+ connector**
8
Port X2 SFP+ connector**
1Gb, 10Gb Ethernet
2Gb, 4Gb, or 8Gb FC
9
Port X3 SFP+ connector**
1Gb, 10Gb Ethernet
2Gb, 4Gb, or 8Gb FC
10
Port X4 SFP+ connector**
1Gb, 10Gb Ethernet
2Gb, 4Gb, or 8Gb FC
11
Port X8 SFP+ connector** †1Gb, 10Gb Ethernet
2Gb, 4Gb, or 8Gb FC
12
Port X7 SFP+ connector** †1Gb, 10Gb Ethernet
2Gb, 4Gb, or 8Gb FC
13
Port X6 SFP+ connector** †1Gb, 10Gb Ethernet
2Gb, 4Gb, or 8Gb FC
1Gb, 10Gb Ethernet
2Gb, 4Gb, or 8Gb FC
Component identification 111
Item
Description
Capable speed
14
Port X5 SFP+ connector** †1Gb, 10Gb Ethernet
2Gb, 4Gb, or 8Gb FC
*QSFP+ Supports 1x40Gb QSFP+ SR4, 1x40Gb QSFP+ SR4 300m, 1x40Gb QSFP+ LR4, 1x40Gb QSFP+ AOC SR4,
1x40Gb QSFP+ DAC CR4, and 40Gb QSFP+ to 4xSFP+ Splitter. 10Gb SFP+ pluggable Ethernet transceiver modules
can be used in QSFP+ ports by using the HP BLc QSFP+ to SFP+ Adapter. LRM, 1Gb, FC, 15m active DAC, and 7m
passive DAC SFP+ pluggable modules are not supported with the adapter in QSFP+ ports.
**SFP+ supports 1000BASE-T-SFP, 1000BASE-SX-SFP, 1000BASE-RJ45-SFP, 10GBASE-LR SFP+, 10GBASE-SR SFP+,
10GBASE-LRM SFP+, and 10GBASE-DAC SFP+ pluggable Ethernet transceiver modules and 2/4/8Gb SFP+ pluggable
Fibre Channel transceiver modules.
†Ports X5/X6 and X7/X8 are paired with each pair carrying a single type of network traffic, either FC or Ethernet. Each
pair must have the same speed for Ethernet, both 1Gb or both 10Gb.
For more information, see the HP Virtual Connect QuickSpecs on the HP QuickSpecs website
(http://www.hp.com/go/qs).
Port LED modes when toggled using the Next button
The port status LEDs are in one of four modes, indicated by the mode LED that is lit green. Use the Next button
to toggle between these modes.
•
PID mode—The PID mode LED is lit green and the port LEDs are amber for Enet stacking links or an FC
port is not online or logged in, green for Enet uplinks or an FC port is connected to a switch, light purple
for Ethernet mirror-to-port, and red if the port has an error.
•
L/A mode—The L/A mode LED is lit green and the color of the port LEDs indicates speed, and activity
when flashing.
•
Ethernet mode—The Ethernet mode LED is lit green. The port LEDs are solid green on ports configured
for Ethernet. All other port LEDs are off.
•
FC mode—The FC mode LED is lit green. The port LEDs are solid green on ports configured for FC. All
other port LEDs are off.
HP Virtual Connect FlexFabric-20/40 F8 Module LEDs
Item
LED description
1
Module locator (UID) Blue = Module ID is selected.
Off = Module ID is not selected.
Status
Component identification 112
Item
LED description
Status
2
Module status
Green = Normal operation
Amber = Degraded condition
Amber flashing = Fault condition
Off = Power off
3
L/A
Green = Port LEDs are in Link/Activity mode
4
PID
Green = Port LEDs are in Port Identifier mode
5
FC Mode
Green = Port LEDs are in FC mode
6
Ethernet
Green = Port LEDs are in Ethernet mode
7
8
9
10
11
12
13
14
X1-X8 port status
PID mode
The PID mode LED is lit green.
Port LEDs:
Amber = The port is configured as an Enet
stacking link or an FC port is not on-line or
logged in.
Green = The port is configured as an Enet
uplink port or an FC port connected to a
switch
Light Purple = The port is configured as an
Enet mirror-to-port.
Red = The port has an error such as an invalid
or unsupported pluggable module detected
Blue = Port identification (locator)
L/A mode
The L/A mode LED is lit green.
Port LEDs:
Green = The port is configured and operating
as an uplink port connected to a data center
fabric at either 10GbE or 4Gb FC.
Green flashing = Port activity at either 10GbE
or 4Gb FC.
Amber = The port is configured and
operating as an uplink port connected to a
data center fabric at either 1GbE or 8Gb FC.
Amber flashing = Port activity at either 1GbE
or 8Gb FC.
Orange = The port is configured and
operating as an uplink port connected to a
data center fabric at 2Gb FC.
Orange flashing = Port activity at 2Gb FC.
Red = Port error, invalid or unsupported
pluggable module detected.
Off = No link
Fibre Channel mode
Green = Port is configured for FC.
Off = Port is not configured for FC.
Ethernet mode
Green = Port is configured for Ethernet.
Off = Port is not configured for Ethernet.
15
16
17
18
Qx port status
For each QSFP+ port configured in 1x40G
mode, the first of the four ports (Qn1) is used
and Qn2 through Qn4 are inactive. For each
QSFP+ port configured in 4x10G mode,
each of the four LEDs represents one 10Gb
Component identification 113
Item
LED description
Status
link (Qn.1–Qn.4).
PID mode
The PID mode LED is lit green.
Port LEDs:
Amber = Port is configured as an Enet
stacking link.
Green = Port is configured as an Enet uplink
port
Light Purple = port is configured as an Enet
mirror-to-port
Red = Port has an error such as an invalid or
unsupported pluggable module detected
Blue = Port identification (locator)
L/A mode
The L/A mode LED is lit green.
Port LEDs:
Green = The port is configured and operating
as an uplink port connected to a data center
fabric at 10GbE.
Green flashing = Port activity at 10GbE.
Purple = The port is configured and operating
as an uplink port connected to a data center
fabric at 40GbE.
Purple flashing = Port activity at 40GbE.
Red = Port error, invalid or unsupported
pluggable module detected.
Off = No link
Fibre Channel mode
Off = Port does not support FC.
Ethernet mode
Green = Port is configured for Ethernet.
Off = Port is not configured for Ethernet.
Component identification 114
HP Virtual Connect FlexFabric-20/40 F8 Module system
maintenance switch
Function
Switch positions*
Default setting
OFF OFF OFF OFF (0000)
Password/DNS reset
FIPS mode
ON OFF OFF OFF (1000)
OFF OFF ON OFF (0010)
*Switch positions are from 1 to 4.
See the following sections for function procedures:
•
"Resetting the Administrator password and DNS settings (on page 128)"
•
"Virtual Connect FIPS mode of operation (on page 34)"
Component identification 115
HP Virtual Connect FlexFabric 10Gb/24-port Module
components and LEDs
HP Virtual Connect FlexFabric 10Gb/24-port Module
components
Ports X1 through X4 support Ethernet or Fibre Channel traffic. Ports X5 through X8 support Ethernet traffic
only. Ports X7 and X8 are multiplexed with the internal 10Gb interface cross-link.
Item
Description
Capable speed
1
—
2
USB 2.0 mini AB connector
(covered)
Next button
3
Port X1 SFP+ connector*
10Gb Ethernet
2Gb, 4Gb, or 8Gb FC
4
Port X2 SFP+ connector*
10Gb Ethernet
2Gb, 4Gb, or 8Gb FC
5
Port X3 SFP+ connector*
10Gb Ethernet
2Gb, 4Gb, or 8Gb FC
6
Port X4 SFP+ connector*
10Gb Ethernet
2Gb, 4Gb, or 8Gb FC
7
Port X5 SFP+ connector**
1Gb or 10Gb Ethernet
8
Port X6 SFP+ connector**
1Gb or 10Gb Ethernet
9
Port X7 SFP+ connector**
1Gb or 10Gb Ethernet
10
Port X8 SFP+ connector**
1Gb or 10Gb Ethernet
—
*Supports 10GBASE-LR SFP+, 10GBASE-SR SFP+, or 10GBASE-DAC SFP+ pluggable Ethernet transceiver modules and
2/4/8Gb SFP+ pluggable Fibre Channel transceiver modules
**Supports 1000BASE-T-SFP, 1000BASE-SX-SFP, 1000BASE-RJ45-SFP, 10GBASE-LR SFP+, 10GBASE-SR SFP+,
10GBASE-LRM SFP+, and 10GBASE-DAC SFP+ pluggable Ethernet transceiver modules
HP Virtual Connect FlexFabric 10Gb/24-port Module LEDs
Component identification 116
Item
LED description
1
Module locator (UID) Blue = Module ID is selected.
Off = Module ID is not selected.
Status
2
Module status
Green = Normal operation
Amber = Degraded condition
Amber flashing = Fault condition
Off = Power off
3
5
7
9
X1-X4 port status
Ethernet mode
Green = Port is configured and operating as
an uplink port connected to a data center
fabric.
Amber = Port is operating as a stacking link
interconnecting Virtual Connect modules.
Amber flashing = SFP module is invalid for
Ethernet mode.
Purple flashing = Port is configured as a
mirror to port.
Blue = Port locator (PID)
Off = Unconfigured
Fibre Channel mode
Green = Port is online and logged in to an
attached switch.
Green flashing = Port is either not online or
not logged in.
Amber flashing = SFP module is invalid for
Fibre Channel mode.
Blue = Port locator (PID)
Off = Unconfigured
4
6
8
10
X1-X4 link/port
activity
Ethernet mode
Green = 10GbE link
Green flashing = 10GbE activity
Off = No link
Fibre Channel mode
Orange = 2Gb link
Orange flashing = 2Gb activity
Green = 4Gb link
Green flashing = 4Gb activity
Amber = 8Gb link
Amber flashing = 8Gb activity
Off = No link
Component identification 117
Item
LED description
Status
11
13
15
17
X5-X8 port status
Green = Port is configured and operating as
an uplink port connected to a data center
fabric.
Amber = Port is operating as a stacking link
interconnecting Virtual Connect modules.
Amber flashing = SFP module is invalid for
Ethernet mode.
Purple flashing = Port is configured as a
mirror to port.
Blue = Port locator (PID)
Off = Unconfigured
12
14
16
18
X5-X8 link/port
activity
Green = 10GbE link
Green flashing = 10GbE activity
Amber = 1GbE link
Amber flashing = 1GbE activity
Off = No link
19
X8 shared port
indicator
Green = Port is multiplexed to the external
SFP+ connector.
Off = Port is multiplexed to the internal 10Gb
interface crosslink.
20
X7 shared port
indicator
Green = Port is multiplexed to the external
SFP+ connector.
Off = Port is multiplexed to the internal 10Gb
interface crosslink.
21
23
26
28
Fibre Channel mode
indicators
Green = The port is configured for Fibre
Channel traffic.
Off = The port is not configured for this mode.
22
24
25
27
Ethernet mode
indicators
Green = The port is configured for Ethernet
traffic.
Off = The port is not configured for this mode.
Component identification 118
HP Virtual Connect FlexFabric 10Gb/24-port Module system
maintenance switch
Function
Switch positions*
Default setting
OFF OFF OFF OFF (0000)
Password/DNS reset
FIPS mode
ON OFF OFF OFF (1000)
OFF OFF ON OFF (0010)
*Switch positions are from 1 to 4.
See the following sections for function procedures:
•
"Resetting the Administrator password and DNS settings (on page 128)"
•
"Virtual Connect FIPS mode of operation (on page 34)"
Component identification 119
HP Virtual Connect 4Gb FC Module (with enhanced
NPIV) components and LEDs
HP Virtual Connect 4Gb FC Module components
Item
Description
Device bays supported
in default
configuration
1
2/4 Gb capable SFP connectors
1-16 (c7000)
1-8 (c3000)
2
Reset button (recessed)
—
In the default configuration (before a Virtual Connect domain is created), all 2/4 Gb capable uplink ports
are grouped into an Uplink Port Group and dynamically distribute connectivity from all server blades.
Component identification 120
HP Virtual Connect 4Gb FC Module LEDs
Item
LED description
Status
1
Module locator
(UID)
Blue = Module ID selected
Off = Module ID not selected
2
Module status
Green = Normal operation
Amber = Degraded condition
Off = Power off
3
Port
Green = Port is configured as the
uplink for one or more server
HBAs.
Amber = Port is not configured.
Blue = Port is selected.
4
Logged in
Green = Logged in to an external
Fibre Channel switch port
Off = Port down, offline, no sync,
or error
5
Activity
Green flashing (variable) = Link
activity
Green flashing (1 Hz) = External
fabric switch does not support
NPIV.
Off = No activity
Component identification 121
HP Virtual Connect 4Gb FC Module system maintenance switch
Switch
Default
Function
1
Off
Reserved
2
Off
Reserved
3
Off
Reserved
4
Off
Reserved
When part of a Virtual Connect domain, Virtual Connect Manager overrides any system maintenance switch
settings.
Component identification 122
HP Virtual Connect 8Gb 24-Port Fibre Channel
Module components and LEDs
HP VC 8Gb 24-Port FC Module components
Item
Description
1
SFP/SFP+ ports supporting 8Gb SFP+ and 1-16
4Gb SFP transceivers
Reset button (recessed)
—
2
Device bays supported
when in default
configuration
Component identification 123
HP VC 8Gb 24-Port FC Module LEDs
Item
LED description
Status
1
Module locator
(UID)
Blue = Module ID selected
Off = Module ID not selected
2
Module status
Green = Normal operation
Amber = Degraded condition
Off = Power off
3
Port link/activity
Green = Port is online, but not
passing traffic
Green slow flashing = Port is
online and not logged in
Green flickering = Port is online
passing traffic
Amber = Port has light or signal,
but not yet online
Amber slow flashing = Port is
disabled (NPIV not enabled or
supported on external devices)
Amber fast flashing = Port is
faulty
Off = No power or signal on the
port
4
Port indicator
Green = Logged in to an external
Fibre Channel switch port
Off = Port down, offline, no sync,
or error
5
Port speed indicator Off = 2 Gb
Green = 4 Gb
Amber = 8 Gb
Component identification 124
HP VC 8Gb 24-Port FC Module system maintenance switch
Switch
Default
Function
1
Off
Reserved (must be in "Off" position)
2
Off
Reserved (must be in "Off" position)
3
Off
Reserved (must be in "Off" position)
4
Off
Off = Module debug and test interface is
inaccessible.
On = Module debug and test interface is accessible.
When part of a Virtual Connect domain, Virtual Connect Manager overrides any system maintenance switch
settings.
Component identification 125
HP Virtual Connect 8Gb 20-Port Fibre Channel
Module components and LEDs
HP VC 8Gb 20-Port FC Module components
Item
Description
Device bays supported
in default
configuration
1
SFP/SFP+ ports supporting 8Gb SFP+ and 1-16 (c7000)
4Gb SFP transceivers
1-8 (c3000)
2
Reset button (recessed)
—
In the default configuration, before a Virtual Connect domain is created, all uplink ports are grouped into an uplink port group and
dynamically distribute connectivity from all server blades.
HP VC 8Gb 20-Port FC Module LEDs
Component identification 126
Item
LED description
Status
1
Module locator
(UID)
Blue = Module ID is selected.
Off = Module ID is not selected.
2
Module status
Green = Normal operation
Amber = Degraded condition
Off = Power off
3
Logged in
Green = Logged in to an external
Fibre Channel switch port
Off = Port down, offline, no sync,
or error
4
Activity
Green flashing (variable) = Link
activity
Green flashing (1 Hz) = External
fabric switch does not support
NPIV.
Off = No activity
5
Port indicator
Green = Port is configured as the
uplink for one or more server
HBAs.
Amber = Port is not configured.
Blue = Port is selected.
HP VC 8Gb 20-Port FC Module system maintenance switch
Switch
Default
Function
1
Off
Reserved
2
Off
Reserved
3
Off
Reserved
4
Off
Reserved
When part of a Virtual Connect domain, Virtual Connect Manager overrides any system maintenance switch
settings.
Component identification 127
Resetting the Administrator password and DNS
settings
To return the VC-Enet module to factory default settings for the Administrator password and DNS settings, you
must access the system maintenance switch. For switch locations, see the appropriate module system
maintenance switch information.
When the VC-Enet module system maintenance switch 1 is in the ON position, the following actions occur:
•
The firmware restores the Administrator account password and DNS Settings to the factory defaults
listed on the module label (without disturbing any other local user accounts).
•
The VC-Enet module management console displays the Administrator account password. To access the
console, see the HP BladeSystem Onboard Administrator User Guide
(http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00705292/c00705292.pdf).
While switch 1 is in the ON position and reserved switches are in the OFF position, passwords are restored
during each power-up sequence, but changes are not allowed.
After switch 1 is returned to the OFF position, the following conditions exist:
•
Users with appropriate privileges can change the Administrator password.
•
The VC-Enet module management console no longer displays the Administrator password.
To recover a password:
1.
Remove the Virtual Connect Ethernet module from interconnect bay 1.
2.
Remove the access panel from the Virtual Connect Ethernet module.
3.
Set switch 1 to the ON position. Be sure that all other switches remain in the OFF position.
4.
Install the access panel.
5.
Install the Virtual Connect Ethernet module into bay 1 and allow the module to power up and reach a
fully booted and operational state (approximately 1 minute).
6.
Remove the Virtual Connect Ethernet module from interconnect bay 2.
This action forces the module in interconnect bay 1 to run the active VC Manager. Because switch 1 is
set, the Administrator password remains at the factory default for interconnect bay 1 (not overwritten by
the change of state because of the failover).
7.
Wait to ensure that the VC Manager has had time to become active on the module in interconnect bay
1. Log in to the VC Manager to confirm it is active.
8.
Insert the Virtual Connect Ethernet module into interconnect bay 2 and allow the module to power on
and reach a fully booted and operational state (approximately 1 minute).
9.
Remove the Virtual Connect Ethernet module from interconnect bay 1.
10.
Remove the access panel from the Virtual Connect Ethernet module.
11.
Set switch 1 to the OFF position. Ensure that all other switches remain in the OFF position.
12.
Install the access panel.
13.
Install the Virtual Connect Ethernet module into interconnect bay 1 and allow the module to power up
and reach a fully booted and operation state (approximately 1 minute).
14.
Log in to the active VC Manager. Use the factory default user name and password to log in to the
module, regardless of its location in interconnect bay 1 or interconnect bay 2.
Component identification 128
15.
Change the Administrator password.
Component identification 129
Regulatory information
Safety and regulatory compliance
For safety, environmental, and regulatory information, see Safety and Compliance Information for Server,
Storage, Power, Networking, and Rack Products, available at the HP website
(http://www.hp.com/support/Safety-Compliance-EnterpriseProducts).
Belarus Kazakhstan Russia marking
Manufacturer
Hewlett-Packard Company, Address: 3000 Hanover Street, Palo Alto, California 94304, U.S.
Local representative information (Russian)
•
HP Russia
•
HP Belarus
•
HP Kazakhstan
Local representative information (Kazakh)
Manufacturing date
The manufacturing date is defined by the serial number (HP serial number format for this product):
CCSYWWZZZZ
Regulatory information 130
Valid date formats include the following:
•
YWW, where Y indicates the year counting from within each new decade, with 2000 as the starting
point. For example, 238: 2 for 2002 and 38 for the week of September 9. In addition, 2010 is
indicated by 0, 2011 by 1, 2012 by 2, 2013 by 3, and so forth.
•
YYWW, where YY indicates the year, using a base year of 2000. For example, 0238: 02 for 2002 and
38 for the week of September 9.
Turkey RoHS material content declaration
Ukraine RoHS material content declaration
Warranty information
HP ProLiant and X86 Servers and Options (http://www.hp.com/support/ProLiantServers-Warranties)
HP Enterprise Servers (http://www.hp.com/support/EnterpriseServers-Warranties)
HP Storage Products (http://www.hp.com/support/Storage-Warranties)
HP Networking Products (http://www.hp.com/support/Networking-Warranties)
Regulatory information 131
Electrostatic discharge
Preventing electrostatic discharge
To prevent damaging the system, be aware of the precautions you need to follow when setting up the system
or handling parts. A discharge of static electricity from a finger or other conductor may damage system
boards or other static-sensitive devices. This type of damage may reduce the life expectancy of the device.
To prevent electrostatic damage:
•
Avoid hand contact by transporting and storing products in static-safe containers.
•
Keep electrostatic-sensitive parts in their containers until they arrive at static-free workstations.
•
Place parts on a grounded surface before removing them from their containers.
•
Avoid touching pins, leads, or circuitry.
•
Always be properly grounded when touching a static-sensitive component or assembly.
Grounding methods to prevent electrostatic discharge
Several methods are used for grounding. Use one or more of the following methods when handling or
installing electrostatic-sensitive parts:
•
Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis. Wrist
straps are flexible straps with a minimum of 1 megohm В±10 percent resistance in the ground cords. To
provide proper ground, wear the strap snug against the skin.
•
Use heel straps, toe straps, or boot straps at standing workstations. Wear the straps on both feet when
standing on conductive floors or dissipating floor mats.
•
Use conductive field service tools.
•
Use a portable field service kit with a folding static-dissipating work mat.
If you do not have any of the suggested equipment for proper grounding, have an authorized reseller install
the part.
For more information on static electricity or assistance with product installation, contact an authorized
reseller.
Electrostatic discharge
132
Support and other resources
Before you contact HP
Be sure to have the following information available before you call HP:
•
Active Health System log (HP ProLiant Gen8 or later products)
Download and have available an Active Health System log for 7 days before the failure was detected.
For more information, see the HP iLO 4 User Guide or HP Intelligent Provisioning User Guide on the HP
website (http://www.hp.com/go/ilo/docs).
•
Onboard Administrator SHOW ALL report (for HP BladeSystem products only)
For more information on obtaining the Onboard Administrator SHOW ALL report, see the HP website
(http://www.hp.com/go/OAlog).
•
Technical support registration number (if applicable)
•
Product serial number
•
Product model name and number
•
Product identification number
•
Applicable error messages
•
Add-on boards or hardware
•
Third-party hardware or software
•
Operating system type and revision level
HP contact information
For United States and worldwide contact information, see the Contact HP website
(http://www.hp.com/go/assistance).
In the United States:
•
To contact HP by phone, call 1-800-334-5144. For continuous quality improvement, calls may be
recorded or monitored.
•
If you have purchased a Care Pack (service upgrade), see the Support & Drivers website
(http://www8.hp.com/us/en/support-drivers.html). If the problem cannot be resolved at the website,
call 1-800-633-3600. For more information about Care Packs, see the HP website
(http://pro-aq-sama.houston.hp.com/services/cache/10950-0-0-225-121.html).
Customer Self Repair
HP products are designed with many Customer Self Repair (CSR) parts to minimize repair time and allow for
greater flexibility in performing defective parts replacement. If during the diagnosis period HP (or HP service
Support and other resources
133
providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, HP will
ship that part directly to you for replacement. There are two categories of CSR parts:
•
Mandatory—Parts for which customer self repair is mandatory. If you request HP to replace these parts,
you will be charged for the travel and labor costs of this service.
•
Optional—Parts for which customer self repair is optional. These parts are also designed for customer
self repair. If, however, you require that HP replace them for you, there may or may not be additional
charges, depending on the type of warranty service designated for your product.
NOTE: Some HP parts are not designed for customer self repair. In order to satisfy the customer warranty,
HP requires that an authorized service provider replace the part. These parts are identified as "No" in the
Illustrated Parts Catalog.
Based on availability and where geography permits, CSR parts will be shipped for next business day
delivery. Same day or four-hour delivery may be offered at an additional charge where geography permits.
If assistance is required, you can call the HP Technical Support Center and a technician will help you over the
telephone. HP specifies in the materials shipped with a replacement CSR part whether a defective part must
be returned to HP. In cases where it is required to return the defective part to HP, you must ship the defective
part back to HP within a defined period of time, normally five (5) business days. The defective part must be
returned with the associated documentation in the provided shipping material. Failure to return the defective
part may result in HP billing you for the replacement. With a customer self repair, HP will pay all shipping
and part return costs and determine the courier/carrier to be used.
For more information about HP's Customer Self Repair program, contact your local service provider. For the
North American program, refer to the HP website (http://www.hp.com/go/selfrepair).
RГ©paration par le client (CSR)
Les produits HP comportent de nombreuses piГЁces CSR (Customer Self Repair = rГ©paration par le client) afin
de minimiser les dГ©lais de rГ©paration et faciliter le remplacement des piГЁces dГ©fectueuses. Si pendant la
période de diagnostic, HP (ou ses partenaires ou mainteneurs agréés) détermine que la réparation peut être
effectuГ©e Г l'aide d'une piГЁce CSR, HP vous l'envoie directement. Il existe deux catГ©gories de piГЁces CSR:
Obligatoire - PiГЁces pour lesquelles la rГ©paration par le client est obligatoire. Si vous demandez Г HP de
remplacer ces piГЁces, les coГ»ts de dГ©placement et main d'Е“uvre du service vous seront facturГ©s.
Facultatif - PiГЁces pour lesquelles la rГ©paration par le client est facultative. Ces piГЁces sont Г©galement
conçues pour permettre au client d'effectuer lui-même la réparation. Toutefois, si vous demandez à HP de
remplacer ces piГЁces, l'intervention peut ou non vous ГЄtre facturГ©e, selon le type de garantie applicable Г votre produit.
REMARQUE: Certaines pièces HP ne sont pas conçues pour permettre au client d'effectuer lui-même la
rГ©paration. Pour que la garantie puisse s'appliquer, HP exige que le remplacement de la piГЁce soit effectuГ©
par un Mainteneur Agréé. Ces pièces sont identifiées par la mention "Non" dans le Catalogue illustré.
Les piГЁces CSR sont livrГ©es le jour ouvrГ© suivant, dans la limite des stocks disponibles et selon votre situation
gГ©ographique. Si votre situation gГ©ographique le permet et que vous demandez une livraison le jour mГЄme
ou dans les 4 heures, celle-ci vous sera facturГ©e. Pour bГ©nГ©ficier d'une assistance tГ©lГ©phonique, appelez le
Centre d'assistance technique HP. Dans les documents envoyГ©s avec la piГЁce de rechange CSR, HP prГ©cise
s'il est nГ©cessaire de lui retourner la piГЁce dГ©fectueuse. Si c'est le cas, vous devez le faire dans le dГ©lai
indiquГ©, gГ©nГ©ralement cinq (5) jours ouvrГ©s. La piГЁce et sa documentation doivent ГЄtre retournГ©es dans
l'emballage fourni. Si vous ne retournez pas la piГЁce dГ©fectueuse, HP se rГ©serve le droit de vous facturer les
coГ»ts de remplacement. Dans le cas d'une piГЁce CSR, HP supporte l'ensemble des frais d'expГ©dition et de
retour, et dГ©termine la sociГ©tГ© de courses ou le transporteur Г utiliser.
Support and other resources
134
Pour plus d'informations sur le programme CSR de HP, contactez votre Mainteneur AgrГ©e local. Pour plus
d'informations sur ce programme en AmГ©rique du Nord, consultez le site Web HP
(http://www.hp.com/go/selfrepair).
Riparazione da parte del cliente
Per abbreviare i tempi di riparazione e garantire una maggiore flessibilitГ nella sostituzione di parti
difettose, i prodotti HP sono realizzati con numerosi componenti che possono essere riparati direttamente
dal cliente (CSR, Customer Self Repair). Se in fase di diagnostica HP (o un centro di servizi o di assistenza
HP) identifica il guasto come riparabile mediante un ricambio CSR, HP lo spedirГ direttamente al cliente per
la sostituzione. Vi sono due categorie di parti CSR:
Obbligatorie – Parti che devono essere necessariamente riparate dal cliente. Se il cliente ne affida la
riparazione ad HP, deve sostenere le spese di spedizione e di manodopera per il servizio.
Opzionali – Parti la cui riparazione da parte del cliente è facoltativa. Si tratta comunque di componenti
progettati per questo scopo. Se tuttavia il cliente ne richiede la sostituzione ad HP, potrebbe dover sostenere
spese addizionali a seconda del tipo di garanzia previsto per il prodotto.
NOTA: alcuni componenti HP non sono progettati per la riparazione da parte del cliente. Per rispettare la
garanzia, HP richiede che queste parti siano sostituite da un centro di assistenza autorizzato. Tali parti sono
identificate da un "No" nel Catalogo illustrato dei componenti.
In base alla disponibilitГ e alla localitГ geografica, le parti CSR vengono spedite con consegna entro il
giorno lavorativo seguente. La consegna nel giorno stesso o entro quattro ore ГЁ offerta con un supplemento
di costo solo in alcune zone. In caso di necessitГ si puГІ richiedere l'assistenza telefonica di un addetto del
centro di supporto tecnico HP. Nel materiale fornito con una parte di ricambio CSR, HP specifica se il cliente
deve restituire dei componenti. Qualora sia richiesta la resa ad HP del componente difettoso, lo si deve
spedire ad HP entro un determinato periodo di tempo, generalmente cinque (5) giorni lavorativi. Il
componente difettoso deve essere restituito con la documentazione associata nell'imballo di spedizione
fornito. La mancata restituzione del componente puГІ comportare la fatturazione del ricambio da parte di HP.
Nel caso di riparazione da parte del cliente, HP sostiene tutte le spese di spedizione e resa e sceglie il
corriere/vettore da utilizzare.
Per ulteriori informazioni sul programma CSR di HP contattare il centro di assistenza di zona. Per il
programma in Nord America fare riferimento al sito Web HP (http://www.hp.com/go/selfrepair).
Customer Self Repair
HP Produkte enthalten viele CSR-Teile (Customer Self Repair), um Reparaturzeiten zu minimieren und höhere
Flexibilität beim Austausch defekter Bauteile zu ermöglichen. Wenn HP (oder ein HP Servicepartner) bei der
Diagnose feststellt, dass das Produkt mithilfe eines CSR-Teils repariert werden kann, sendet Ihnen HP dieses
Bauteil zum Austausch direkt zu. CSR-Teile werden in zwei Kategorien unterteilt:
Zwingend – Teile, für die das Customer Self Repair-Verfahren zwingend vorgegeben ist. Wenn Sie den
Austausch dieser Teile von HP vornehmen lassen, werden Ihnen die Anfahrt- und Arbeitskosten fГјr diesen
Service berechnet.
Optional – Teile, für die das Customer Self Repair-Verfahren optional ist. Diese Teile sind auch für Customer
Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten,
können bei diesem Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche
Kosten anfallen.
Support and other resources
135
HINWEIS: Einige Teile sind nicht fГјr Customer Self Repair ausgelegt. Um den Garantieanspruch des
Kunden zu erfГјllen, muss das Teil von einem HP Servicepartner ersetzt werden. Im illustrierten Teilekatalog
sind diese Teile mit „No“ bzw. „Nein“ gekennzeichnet.
CSR-Teile werden abhängig von der Verfügbarkeit und vom Lieferziel am folgenden Geschäftstag geliefert.
FГјr bestimmte Standorte ist eine Lieferung am selben Tag oder innerhalb von vier Stunden gegen einen
Aufpreis verfügbar. Wenn Sie Hilfe benötigen, können Sie das HP technische Support Center anrufen und
sich von einem Mitarbeiter per Telefon helfen lassen. Den Materialien, die mit einem CSR-Ersatzteil geliefert
werden, können Sie entnehmen, ob das defekte Teil an HP zurückgeschickt werden muss. Wenn es
erforderlich ist, das defekte Teil an HP zurГјckzuschicken, mГјssen Sie dies innerhalb eines vorgegebenen
Zeitraums tun, in der Regel innerhalb von fünf (5) Geschäftstagen. Das defekte Teil muss mit der zugehörigen
Dokumentation in der Verpackung zurГјckgeschickt werden, die im Lieferumfang enthalten ist. Wenn Sie das
defekte Teil nicht zurГјckschicken, kann HP Ihnen das Ersatzteil in Rechnung stellen. Im Falle von Customer
Self Repair kommt HP fГјr alle Kosten fГјr die Lieferung und RГјcksendung auf und bestimmt den
Kurier-/Frachtdienst.
Weitere Informationen Гјber das HP Customer Self Repair Programm erhalten Sie von Ihrem Servicepartner
vor Ort. Informationen Гјber das CSR-Programm in Nordamerika finden Sie auf der HP Website unter
(http://www.hp.com/go/selfrepair).
Reparaciones del propio cliente
Los productos de HP incluyen muchos componentes que el propio usuario puede reemplazar (Customer Self
Repair, CSR) para minimizar el tiempo de reparaciГіn y ofrecer una mayor flexibilidad a la hora de realizar
sustituciones de componentes defectuosos. Si, durante la fase de diagnГіstico, HP (o los proveedores o socios
de servicio de HP) identifica que una reparaciГіn puede llevarse a cabo mediante el uso de un componente
CSR, HP le enviarГЎ dicho componente directamente para que realice su sustituciГіn. Los componentes CSR se
clasifican en dos categorГ­as:
•
Obligatorio: componentes para los que la reparaciГіn por parte del usuario es obligatoria. Si solicita a
HP que realice la sustituciГіn de estos componentes, tendrГЎ que hacerse cargo de los gastos de
desplazamiento y de mano de obra de dicho servicio.
•
Opcional: componentes para los que la reparaciГіn por parte del usuario es opcional. Estos
componentes tambiГ©n estГЎn diseГ±ados para que puedan ser reparados por el usuario. Sin embargo, si
precisa que HP realice su sustituciГіn, puede o no conllevar costes adicionales, dependiendo del tipo de
servicio de garantГ­a correspondiente al producto.
NOTA: Algunos componentes no estГЎn diseГ±ados para que puedan ser reparados por el usuario. Para que
el usuario haga valer su garantГ­a, HP pone como condiciГіn que un proveedor de servicios autorizado
realice la sustituciГіn de estos componentes. Dichos componentes se identifican con la palabra "No" en el
catГЎlogo ilustrado de componentes.
SegГєn la disponibilidad y la situaciГіn geogrГЎfica, los componentes CSR se enviarГЎn para que lleguen a su
destino al siguiente dГ­a laborable. Si la situaciГіn geogrГЎfica lo permite, se puede solicitar la entrega en el
mismo dГ­a o en cuatro horas con un coste adicional. Si precisa asistencia tГ©cnica, puede llamar al Centro de
asistencia tГ©cnica de HP y recibirГЎ ayuda telefГіnica por parte de un tГ©cnico. Con el envГ­o de materiales
para la sustituciГіn de componentes CSR, HP especificarГЎ si los componentes defectuosos deberГЎn
devolverse a HP. En aquellos casos en los que sea necesario devolver algГєn componente a HP, deberГЎ
hacerlo en el periodo de tiempo especificado, normalmente cinco dГ­as laborables. Los componentes
defectuosos deberГЎn devolverse con toda la documentaciГіn relacionada y con el embalaje de envГ­o. Si no
enviara el componente defectuoso requerido, HP podrГЎ cobrarle por el de sustituciГіn. En el caso de todas
Support and other resources
136
sustituciones que lleve a cabo el cliente, HP se harГЎ cargo de todos los gastos de envГ­o y devoluciГіn de
componentes y escogerГЎ la empresa de transporte que se utilice para dicho servicio.
Para obtener mГЎs informaciГіn acerca del programa de Reparaciones del propio cliente de HP, pГіngase en
contacto con su proveedor de servicios local. Si estГЎ interesado en el programa para NorteamГ©rica, visite
la pГЎgina web de HP siguiente (http://www.hp.com/go/selfrepair).
Customer Self Repair
Veel onderdelen in HP producten zijn door de klant zelf te repareren, waardoor de reparatieduur tot een
minimum beperkt kan blijven en de flexibiliteit in het vervangen van defecte onderdelen groter is. Deze
onderdelen worden CSR-onderdelen (Customer Self Repair) genoemd. Als HP (of een HP Service Partner) bij
de diagnose vaststelt dat de reparatie kan worden uitgevoerd met een CSR-onderdeel, verzendt HP dat
onderdeel rechtstreeks naar u, zodat u het defecte onderdeel daarmee kunt vervangen. Er zijn twee
categorieГ«n CSR-onderdelen:
Verplicht: Onderdelen waarvoor reparatie door de klant verplicht is. Als u HP verzoekt deze onderdelen
voor u te vervangen, worden u voor deze service reiskosten en arbeidsloon in rekening gebracht.
Optioneel: Onderdelen waarvoor reparatie door de klant optioneel is. Ook deze onderdelen zijn ontworpen
voor reparatie door de klant. Als u echter HP verzoekt deze onderdelen voor u te vervangen, kunnen
daarvoor extra kosten in rekening worden gebracht, afhankelijk van het type garantieservice voor het
product.
OPMERKING: Sommige HP onderdelen zijn niet ontwikkeld voor reparatie door de klant. In verband met
de garantievoorwaarden moet het onderdeel door een geautoriseerde Service Partner worden vervangen.
Deze onderdelen worden in de geГЇllustreerde onderdelencatalogus aangemerkt met "Nee".
Afhankelijk van de leverbaarheid en de locatie worden CSR-onderdelen verzonden voor levering op de
eerstvolgende werkdag. Levering op dezelfde dag of binnen vier uur kan tegen meerkosten worden
aangeboden, indien dit mogelijk is gezien de locatie. Indien assistentie gewenst is, belt u een HP Service
Partner om via de telefoon technische ondersteuning te ontvangen. HP vermeldt in de documentatie bij het
vervangende CSR-onderdeel of het defecte onderdeel aan HP moet worden geretourneerd. Als het defecte
onderdeel aan HP moet worden teruggezonden, moet u het defecte onderdeel binnen een bepaalde
periode, gewoonlijk vijf (5) werkdagen, retourneren aan HP. Het defecte onderdeel moet met de
bijbehorende documentatie worden geretourneerd in het meegeleverde verpakkingsmateriaal. Als u het
defecte onderdeel niet terugzendt, kan HP u voor het vervangende onderdeel kosten in rekening brengen. Bij
reparatie door de klant betaalt HP alle verzendkosten voor het vervangende en geretourneerde onderdeel en
kiest HP zelf welke koerier/transportonderneming hiervoor wordt gebruikt.
Neem contact op met een Service Partner voor meer informatie over het Customer Self Repair programma
van HP. Informatie over Service Partners vindt u op de HP website (http://www.hp.com/go/selfrepair).
Reparo feito pelo cliente
Os produtos da HP são projetados com muitas peças para reparo feito pelo cliente (CSR) de modo a
minimizar o tempo de reparo e permitir maior flexibilidade na substituição de peças com defeito. Se,
durante o período de diagnóstico, a HP (ou fornecedores/parceiros de serviço da HP) concluir que o reparo
pode ser efetuado pelo uso de uma peça CSR, a peça de reposição será enviada diretamente ao cliente.
Existem duas categorias de peças CSR:
Obrigatória – Peças cujo reparo feito pelo cliente é obrigatório. Se desejar que a HP substitua essas peças,
serão cobradas as despesas de transporte e mão-de-obra do serviço.
Support and other resources
137
Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o
reparo feito pelo cliente. No entanto, se desejar que a HP as substitua, pode haver ou não a cobrança de
taxa adicional, dependendo do tipo de serviço de garantia destinado ao produto.
OBSERVAÇÃO: Algumas peças da HP não são projetadas para o reparo feito pelo cliente. A fim de
cumprir a garantia do cliente, a HP exige que um técnico autorizado substitua a peça. Essas peças estão
identificadas com a marca "No" (Não), no catálogo de peças ilustrado.
Conforme a disponibilidade e o local geográfico, as peças CSR serão enviadas no primeiro dia útil após o
pedido. Onde as condições geográficas permitirem, a entrega no mesmo dia ou em quatro horas pode ser
feita mediante uma taxa adicional. Se precisar de auxГ­lio, entre em contato com o Centro de suporte tГ©cnico
da HP para que um técnico o ajude por telefone. A HP especifica nos materiais fornecidos com a peça CSR
de reposição se a peça com defeito deve ser devolvida à HP. Nos casos em que isso for necessário, é
preciso enviar a peça com defeito à HP dentro do período determinado, normalmente cinco (5) dias úteis.
A peça com defeito deve ser enviada com a documentação correspondente no material de transporte
fornecido. Caso não o faça, a HP poderá cobrar a reposição. Para as peças de reparo feito pelo cliente, a
HP paga todas as despesas de transporte e de devolução da peça e determina a transportadora/serviço
postal a ser utilizado.
Para obter mais informações sobre o programa de reparo feito pelo cliente da HP, entre em contato com o
fornecedor de serviços local. Para o programa norte-americano, visite o site da HP
(http://www.hp.com/go/selfrepair).
Support and other resources
138
Support and other resources
139
Support and other resources
140
Acronyms and abbreviations
BPDU
Bridge Protocol Data Unit
DAC
direct attach cable
DHCP
Dynamic Host Configuration Protocol
DNS
domain name system
FC
Fibre Channel
FCoE
Fibre Channel over Ethernet
FIPS
Federal Information Processing Standard
HBA
host bus adapter
iSCSI
Internet Small Computer System Interface
ISL
Inter-Switch Link
LACP
Link Aggregation Control Protocol
LAG
link aggregation group
Acronyms and abbreviations
141
LLDP
Link Layer Discovery Protocol
MAC
Media Access Control
MIB
management information base
NPIV
N_Port ID Virtualization
OA
Onboard Administrator
POST
Power-On Self Test
RDP
Rapid Deployment Pack
SFP
small form-factor pluggable
SSL
Secure Sockets Layer
TFTP
Trivial File Transfer Protocol
USB
universal serial bus
VCDG
Virtual Connect Domain Group
VCEM
Virtual Connect Enterprise Manager
VCM
Virtual Connect Manager
Acronyms and abbreviations
142
VCSU
Virtual Connect Support Utility
VLAN
virtual local-area network
WWN
World Wide Name
XFP
10 Gb small form factor pluggable
Acronyms and abbreviations
143
Documentation feedback
HP is committed to providing documentation that meets your needs. To help us improve the documentation,
send any errors, suggestions, or comments to Documentation Feedback (mailto:[email protected]).
Include the document title and part number, version number, or the URL when submitting your feedback.
Index
144
Index
A
About menu 62
accessing HP Virtual Connect Manager 12, 60
ActiveX 58
adding enclosures 67
Advanced Network Settings 81
allowing double density device bays 65
assign server profiles 98
assigned MAC addresses 74, 76
assigned WWNs 90
authorized reseller 132, 133
B
backup module 12, 15, 29
bay configuration guidelines 19
browser requirements 58
BSMI notice 130
buttons 104
C
cabling 24, 47
Canadian notice 130
check-pointing 52
Cisco Core switch 50
CLI (Command Line Interface) 60
command line interface, using 60
command line overview 60
components 104, 108, 111, 116, 120, 123, 126
components, HP VC 8Gb 20-Port FC Module 126
components, HP VC 8Gb 24-Port FC Module 123
components, HP Virtual Connect 116
components, HP Virtual Connect 4Gb FC
Module 120
components, HP Virtual Connect Flex-10 10Gb
Ethernet Module 104
components, HP Virtual Connect Flex-10/10D
Module 108
components, HP Virtual Connect FlexFabric-20/40 F8
Module 111
configuration example 50
configuration, default module 13
configuration, redundant 24
connecting multiple enclosures 29
connectors 104
contact information 133
contacting HP 133
cookies 58
create server profile definition 96
create server profiles, Server Profile Wizard 101
customer self repair (CSR) 133
D
data center connections, verifying 102
Declaration of Conformity 130, 131
define network 80
define network connection 79, 86
define SAN fabric 91, 93
define shared uplink set 83
direct connect VC domains 34
DNS label 36, 39
DNS settings 128
documentation 6, 144
domain name 69
domain setup wizard 63
domains, directly connecting 34
double density device bays, allowing 65, 68
double-dense server blades 68
E
EBIPA (Enclosure Bay IP Addressing) 22
electrostatic discharge 132
enable local users 70
Enabling FIPS mode 35
enclosure import 65, 67
enclosure recovery 65, 68
Ethernet connections 97
Ethernet module, installing 36
European Union notice 130
external connections 47
external port connections, verifying 103
external uplink ports 80, 83
F
factory default settings 46
failover 15, 62
Index
145
FC connections 97
FC module bay configuration, multiple enclosures 32
FC module, installing 41
Federal Communications Commission (FCC)
notice 130
Fibre Channel settings (WWN) 89
finish wizard 73, 87, 94
FIPS Mode 34
FIPS mode guidelines 34
FIPS mode indicators 36
FIPS Mode, enabling 35
firmware, Onboard Administrator requirements 60
Flex-10 installation guidelines 20
FlexFabric module bay configuration, multiple
enclosures 32
FlexFabric module, installation 39
FlexNIC 8
G
general settings 69
grounding methods 132
H
hardware setup 12, 36, 39, 41
help resources 133
high availability support 24, 52
HP technical support 133
HP VC FlexFabric 10Gb/24-port Module
guidelines 21
HP VC FlexFabric-20/40 F8 Module requirements 22
HP Virtual Connect 4Gb FC Module 122
HP Virtual Connect 4Gb FC Module (with enhanced
NPIV) components and LEDs 120
HP Virtual Connect 8Gb 20-Port FC Module 126,
127
HP Virtual Connect 8Gb 20-Port FC Module,
upgrading to 53
HP Virtual Connect 8Gb 24-Port FC Module 123,
125
HP Virtual Connect 8Gb 24-Port FC Module,
upgrading to 53
HP Virtual Connect Flex-10 10Gb Ethernet
Module 107
HP Virtual Connect Flex-10 10Gb Ethernet Module
components and LEDs 104
HP Virtual Connect Flex-10 module, upgrading to 54
HP Virtual Connect Flex10/10D Module 21, 110
HP Virtual Connect Flex-10/10D Module components
and LEDs 108
HP Virtual Connect Flex-10/10D module, upgrading
to 54
HP Virtual Connect FlexFabric 10Gb/24-port
Module 119
HP Virtual Connect FlexFabric 10Gb/24-port Module
components and LEDs 116
HP Virtual Connect FlexFabric-20/40 F8 Module
components and LEDs 111
HP Virtual Connect Manager 58
I
idle user session timeout 70
import enclosures 67
importing enclosures 67
installation guidelines, Flex-10 module 20
installation requirements 15
installation, FlexFabric module 39
installation, management card 15
installing, Ethernet module 36
installing, FC module 41
interconnect modules, removing 52
interconnect modules, replacing 52
Internet Explorer support 58
iSCSI MAC address 74
iSCSI support 74
J
Japanese notice 130
Javascript 58
L
LACP timer configuration 80
LEDs 105, 108, 112, 116, 121, 124, 126
LEDs, HP Virtual Connect 4Gb FC Module 121
LEDs, HP Virtual Connect 8Gb 20-Port FC
Module 126
LEDs, HP Virtual Connect 8Gb 24-Port FC
module 124
LEDs, HP Virtual Connect Flex-10 10Gb Ethernet
Module 105
LEDs, HP Virtual Connect Flex10/10D Module 108
LEDs, HP Virtual Connect FlexFabric 10Gb/24-port
Module 116
LEDs, HP Virtual Connect FlexFabric-20/40 F8
Module 112
licensed software and MACs or WWNs 59
local user accounts 70
logging in 61
logical interconnects 27
Index
146
loop prevention 28
M
MAC address settings 74
mode, FIPS 34
modifications, FCC notice 130
module configuration, default 13
module removal and replacement 52
Mozilla support 58
multiple enclosures, adding and importing 67
multiple enclosures, FC module bay configuration 32
multiple enclosures, FlexFabric module bay
configuration 32
multiple enclosures, managing 9, 29
multiple enclosures, using 9
N
name server profiles 100
native VLAN 83
network mapping 47
node WWN 89
NPIV 15
O
Onboard Administrator login credentials 64
Onboard Administrator module, removing 57
Onboard Administrator, accessing Virtual Connect
Module 60
Onboard Administrator, required firmware
revision 60
P
password, resetting 128
phone numbers 133
planning the installation 8
port WWN 89
pre-deployment planning 10
primary module 12, 15, 29, 52, 60
private networks 80
recovering remote enclosures 62
recovery, enclosure 68
Red Hat procedures 59
redundant configuration 24
regulatory compliance identification numbers 130
regulatory compliance notices 130
remote enclosures, recovering 62
remove module from an enclosure 52
removing the Onboard Administrator 57
replacing the Onboard Administrator 57
resetting the adminsitrator password 128
resetting the system 62
resources 133
running the setup wizards 63
S
SAN fabrics, defining available 91
serial number settings 95
series number 130
server profile troubleshooting 97
server profiles 97
setup wizard 63, 73, 94
SFP transceiver, installing 44
SFP transceiver, removing 46
shared port operation 106
shared server links 77
Smart Link 80
stacking links 23
static electricity 132
strong password 70
support 133
support and other resources 133
supported configurations 16, 17
system maintenance switch 107, 110, 115, 119,
122, 125, 127
T
technical support 133
telephone numbers 133
troubleshooting, server profiles 97
Q
U
QSFP+ transceiver, installing 44
QSFP+ transceiver, removing 46
upgrading to an HP Virtual Connect 8Gb 20-Port FC
Module 53
upgrading to an HP Virtual Connect 8Gb 24-Port FC
Module 53
upgrading to an HP Virtual Connect Flex-10
Module 54
R
RDP, using with Virtual Connect 10
recommended stacking connections 24
Index
147
upgrading to an HP Virtual Connect Flex-10/10D
module 54
upgrading to an HP Virtual Connect FlexFabric
Module 54
Upgrading to an HP Virtual Connect FlexFabric
Module from a VC-FC module 56
user accounts 70
user settings 72
using multiple enclosures 9
V
VC domains, directly connecting 34
VC-assigned MAC addresses 76
verify data center connections 102
verify link and speed 103
verify network status 103
Virtual Connect documentation 6
Virtual Connect Manager setup overview 13
Virtual Connect overview 8
VLAN tagging 47, 77
VLAN tunneling, enable or disable 80
W
website, HP 133
WWN settings 89
WWN, selecting a range 90
Index
148
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF