TranquilityВ® Vertical
Stack (TSL) Series
Submittal Data
Models TSL09 - 36
60Hz - HFC-410A
SUBMITTAL DATA - I-P UNITS
Unit Designation:
English Language/I-P Units
Job Name:
Architect:
Engineer:
Contractor:
PERFORMANCE DATA
Cooling Capacity:
Btuh
EER:
Heating Capacity:
Btuh
COP:
Ambient Air Temp:
В°F
Entering Water Temp (Clg):
В°F
Entering Air Temp (Clg):
В°F
Entering Water Temp (Htg):
В°F
Entering Air Temp (Htg):
В°F
Airflow:
CFM
Fan Speed or Motor/RPM/Turns:
Revised: 16 December, 2014
Operating Weight:
(lb)
ELECTRICAL DATA
Power Supply:
Volts
Phase
Minimum Circuit Ampacity:
ClimateMaster works continually to improve its products. As a result, the design and specifications of each
product at the time of order may be changed without notice and may not be as described herein. Please contact
ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and
specifications. Statements and other information contained herein are not express warranties and do not form the
basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products.
The latest version of this document is available at climatemaster.com.
*LC1007*
LC1007
Revised: 16 December, 2014
Maximum Overcurrent Protection:
Hz
TranquilityВ® Vertical
Stack (TSL) Series
Submittal Data
Models TSL09 - 36
60Hz - HFC-410A
SUBMITTAL DATA - S-I UNITS
Unit Designation:
English Language/S-I Units
Job Name:
Architect:
Engineer:
Contractor:
PERFORMANCE DATA
Cooling Capacity:
kW
EER:
Heating Capacity:
kW
COP:
Ambient Air Temp:
В°C
Entering Water Temp (Clg):
В°C
Entering Air Temp (Clg):
В°C
Entering Water Temp (Htg):
В°C
Entering Air Temp (Htg):
В°C
Airflow:
l/s
Fan Speed or Motor/RPM/Turns:
Revised: 16 December, 2014
Operating Weight:
(kg)
ELECTRICAL DATA
Power Supply:
Volts
Phase
Minimum Circuit Ampacity:
ClimateMaster works continually to improve its products. As a result, the design and specifications of each
product at the time of order may be changed without notice and may not be as described herein. Please contact
ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and
specifications. Statements and other information contained herein are not express warranties and do not form the
basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products.
The latest version of this document is available at climatemaster.com.
*LC1007*
LC1007
Revised: 16 December, 2014
Maximum Overcurrent Protection:
Hz
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Table of Contents
Unit Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
iGateв„ў Communicating Controls . . . . . . . . . . . . . . . . . . . .
vFlowв„ў Internal Variable Water Flow Control . . . . . . . . . .
Selection Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TSL Series Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . .
Performance Data – AHRI/ASHRAE/ISO 13256-1 . . . . . . . .
Performance Data – Selection Notes . . . . . . . . . . . . . . . . .
Performance Data – TSL09 with PSC Motor . . . . . . . . . . . .
Performance Data – TSL12 with PSC Motor . . . . . . . . . . . .
Performance Data – TSL15 with PSC Motor . . . . . . . . . . . .
Performance Data – TSL18 with PSC Motor . . . . . . . . . . . .
Performance Data – TSL24 with PSC Motor . . . . . . . . . . . .
Performance Data – TSL30 with PSC Motor . . . . . . . . . . . .
Performance Data – TSL36 with PSC Motor . . . . . . . . . . . .
Performance Data – TSL09 with ECM Motor . . . . . . . . . . . .
Performance Data – TSL12 with ECM Motor . . . . . . . . . . . .
Performance Data – TSL15 with ECM Motor . . . . . . . . . . . .
Performance Data – TSL18 with ECM Motor . . . . . . . . . . . .
Performance Data – TSL24 with ECM Motor . . . . . . . . . . . .
Performance Data – TSL30 with ECM Motor . . . . . . . . . . . .
Performance Data – TSL36 with ECM Motor . . . . . . . . . . . .
Performance Data Correction Tables . . . . . . . . . . . . . . . .
PSC Blower Performance Data . . . . . . . . . . . . . . . . . . . . .
ECM Blower Performance Data . . . . . . . . . . . . . . . . . . . . .
Sound Data - Case Radiated . . . . . . . . . . . . . . . . . . . . . . .
Sound Data - Ducted Discharge . . . . . . . . . . . . . . . . . . . .
Physical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TSL Series Wiring Diagram Matrix . . . . . . . . . . . . . . . . . . .
Typical Wiring Diagram – TSL09 - 36 CXM with PSC Motor . .
Typical Wiring Diagram – TSL09 - 36 DXM2 with PSC Motor
Typical Wiring Diagram – TSL09 - 12 DXM2 with ECM Motor
Typical Wiring Diagram – TSL15 - 36 DXM2 with ECM Motor
Typical Wiring Diagram – Single Phase TSL Units with DXM2
Emergency Shutdown, & Pump Restart. . . . . . . . . . . . . . . .
Typical Unit - Exploded View . . . . . . . . . . . . . . . . . . . . . . .
TSL – Standard Unit, Risers Ship Separate . . . . . . . . . . . .
Cabinet Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cabinet Slot Dimensions and Riser Arrangements . . . . . . .
Typical Cabinet Installation - Flush . . . . . . . . . . . . . . . . .
Typical Cabinet Installation - Recessed . . . . . . . . . . . . . . .
Hinged “G” Style Return Air Panel – AVHSG Series . . . . . .
AHH Series – Stainless Steel Braided Hose Kit . . . . . . . . .
ACST Cabinet Stands . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Thermostats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TSL Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ECM Blower Motor (Optional) . . . . . . . . . . . . . . . . . . . . . .
Riser GPM Definitions and Sizing . . . . . . . . . . . . . . . . . . .
Riser Diameter Sizing . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Riser Length Definitions and Calculations . . . . . . . . . . . .
Riser Extension Definitions and Calculations . . . . . . . . . .
Shipping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Engineering Specifications . . . . . . . . . . . . . . . . . . . . . . . .
Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
*Page Number
. . . . . . . . . . . . . . . . . . . . . . . . .4
. . . . . . . . . . . . . . . . . . . . . . . . .6
. . . . . . . . . . . . . . . . . . . . . . . . .7
. . . . . . . . . . . . . . . . . . . . . . . . .8
. . . . . . . . . . . . . . . . . . . . . . . . 10
. . . . . . . . . . . . . . . . . . . . . . . . 13
. . . . . . . . . . . . . . . . . . . . . . . . 14
. . . . . . . . . . . . . . . . . . . . . . . . 15
. . . . . . . . . . . . . . . . . . . . . . . . 16
. . . . . . . . . . . . . . . . . . . . . . . . 17
. . . . . . . . . . . . . . . . . . . . . . . . 18
. . . . . . . . . . . . . . . . . . . . . . . . 19
. . . . . . . . . . . . . . . . . . . . . . . . 20
. . . . . . . . . . . . . . . . . . . . . . . . 21
. . . . . . . . . . . . . . . . . . . . . . . . 22
. . . . . . . . . . . . . . . . . . . . . . . . 23
. . . . . . . . . . . . . . . . . . . . . . . . 24
. . . . . . . . . . . . . . . . . . . . . . . . 25
. . . . . . . . . . . . . . . . . . . . . . . . 26
. . . . . . . . . . . . . . . . . . . . . . . . 27
. . . . . . . . . . . . . . . . . . . . . . . . 28
. . . . . . . . . . . . . . . . . . . . . . . . 36
. . . . . . . . . . . . . . . . . . . . . . . . 38
. . . . . . . . . . . . . . . . . . . . . . . . 39
. . . . . . . . . . . . . . . . . . . . . . . . 40
. . . . . . . . . . . . . . . . . . . . . . . . 41
. . . . . . . . . . . . . . . . . . . . . . . . 42
. . . . . . . . . . . . . . . . . . . . . . . . 45
. . . . . . . . . . . . . . . . . . . . . . . . 46
. . . . . . . . . . . . . . . . . . . . . . . . 47
. . . . . . . . . . . . . . . . . . . . . . . . 48
. . . . . . . . . . . . . . . . . . . . . . . . 49
Controller with Night Setback,
. . . . . . . . . . . . . . . . . . . . . . . . 50
. . . . . . . . . . . . . . . . . . . . . . . . 51
. . . . . . . . . . . . . . . . . . . . . . . . 52
. . . . . . . . . . . . . . . . . . . . . . . . 53
. . . . . . . . . . . . . . . . . . . . . . . . 54
. . . . . . . . . . . . . . . . . . . . . . . . 55
. . . . . . . . . . . . . . . . . . . . . . . . 56
. . . . . . . . . . . . . . . . . . . . . . . . 57
. . . . . . . . . . . . . . . . . . . . . . . . 58
. . . . . . . . . . . . . . . . . . . . . . . . 58
. . . . . . . . . . . . . . . . . . . . . . . . 59
. . . . . . . . . . . . . . . . . . . . . . . . 60
. . . . . . . . . . . . . . . . . . . . . . . . 61
. . . . . . . . . . . . . . . . . . . . . . . . 63
. . . . . . . . . . . . . . . . . . . . . . . . 64
. . . . . . . . . . . . . . . . . . . . . . . . 65
. . . . . . . . . . . . . . . . . . . . . . . . 66
. . . . . . . . . . . . . . . . . . . . . . . . 67
. . . . . . . . . . . . . . . . . . . . . . . . 68
. . . . . . . . . . . . . . . . . . . . . . . . 76
*Document page number is shown next to part number (e.g. LCXXX - 3 = page 3). Since not all pages are typically
used in the submittals process, the page number in the lower right corner can still be used (page ____of_____).
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 3
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Unit Features
TRANQUILITYВ® VERTICAL STACK (TSL) SERIES WITH
EARTHPUREВ® REFRIGERANT
The TranquilityВ® Vertical Stack (TSL) Series offers an
innovative, labor-saving solution for spaces where
individual, quiet control of the heating and cooling
system is important. TSL units consist of 2 major
components - cabinet behind finished wall and slide
in refrigeration chassis. Vertical risers running behind
cabinet are especially ideal for multi-story buildings.
Risers shipped separate so riser stack can be completely
assembled, pressure tested, filled, and water circulated.
This allows floor by floor completion and occupancy
before construction is completed. The TSL Series exceeds
ASHRAE 90.1 efficiencies, yet maintains small cabinet
dimensions. Using EarthPureВ® (HFC-410A) refrigerant, the
TSL Series not only protects the environment, it does so
while delivering unprecedented comfort, efficiency, and
reliability.
Available in sizes 3/4 ton (2.6 kW) through 3 tons (10.6 kW)
with numerous cabinet, water piping and control choices,
the TSL Series offers a wide range of units for most any
installation. The TSL has an extended range refrigerant
circuit, capable of ground loop (geothermal) applications
as well as water loop (boiler-tower) applications. Standard
features are many. Microprocessor controls, TXV metering
device, galvanized steel cabinet, torsion-flex blower
motor mounting, and (optional) ECM motor for all models
are just some of the features of the innovative TSL Series.
ClimateMaster’s exclusive double isolation compressor
mounting system makes the TSL Series the quietest
vertical stack units on the market. Compressors are
mounted on specially engineered sound-tested EPDM
grommets to a heavy gauge base pan, which is then
isolated from the cabinet base with grommets under
the condensate pan for maximized vibration/sound
attenuation. Factory-installed internal options such
as DDC controls, ECM motors, single speed pump,
variable speed pump, auto flow water regulator, 2-way
water solenoid valve, and modulating water valve allow
customized design solutions.
iGateв„ў technology is the next generation in intelligent
control by using two-way communication to provide
a gateway into the system. The iGateв„ў control system
allows end-users and contractors to monitor the performance of the unit, custom tailor its operation, and
diagnose any issues, right from the ATC thermostat, or
diagnostic tool.
The iGateв„ў communications hub is the DXM2 intelligent
controller, which analyzes the status of sensors and smart
components (which are also two-way communicating)
to determine how best to operate the system for optimal comfort, efficiency and long-term reliability. All of
this information is passed to the iGateв„ў thermostat (or
diagnostic tool), where it can be displayed in plain English. And since communication is both ways, the iGateв„ў
thermostat can also be used to configure and tailor the
system without even touching the unit.
vFlowв„ў variable water flow technology represents a major
advance in water-source system performance made possible through the iGateв„ў system. vFlowв„ў not only builds
the major water circulation components into the unit for
a clean installation, it also intelligently varies the water
flow to minimize pump energy consumption and improve
system reliability. vFlowв„ў also allows cooling and heating
operation across the entire 20–120°F entering water conditions, providing ultimate flexibility in designing watersource heating and cooling systems with ClimateMaster
vFlowв„ў units.
The heart of vFlowв„ў is either a variable-speed pump or
modulating water valve directly linked into the iGateв„ў
system. Water flow is automatically varied based on T,
in turn changes in unit capacity level (stage) and source
water temperature to maintain optimum system performance. vFlowв„ў allows the use of direct return piping,
while eliminating external two-ways valves and automatic
flow regulators. vFlowв„ў systems are inherently selfbalancing. vFlowв„ў with automatically modulating valves
deliver superior value by being priced competitively with
inefficient two-way valve with auto flow regulator options.
vFlowв„ў systems provide reduced water pumping power
compared to traditional fixed-speed pumping or fixed
water flow systems and protects the unit against extreme
operating conditions, extending the life of the compressor and air coil. Since vFlowв„ў is built inside the unit, it
also saves on installation time and makes for a very clean
and compact installation. The TranquilityВ® TSL Series
water-source heat pumps are designed to meet the challenges of today’s HVAC demands with one of the most
innovative products available on the market.
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 4
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
The TSL Series Vertical Stack Water-Source Heat Pumps
are designed to meet the challenges of today’s HVAC
demands with a low cost/high value solution.
UNIT FEATURES
• Sizes 09 (3/4 ton, 2.6 kW) through 36 (3 ton, 10.6 kW)
• Environmentally-friendly EarthPure® (HFC-410A) zero
ozone depletion refrigerant
• High efficiency rotary and scroll compressors
• Exceeds ASHRAE 90.1 efficiencies
• Removable chassis allows staged installation and ease
of maintenance
• Galvanized steel cabinet
• Chassis rests on rubber grommeted isolated
condensate pan for vibration reduction.
• Double isolation of compressor for quiet operation
• UltraQuiet option
• Air coil hairpins are tin-plated; Option non-plated
• TXV metering device
• Cabinet construction for unit or remote-mounted
controls
• Two fan speed capability with CXM or DXM2
• Microprocessor controls standard (optional DXM2 and/
or DDC controls)
• Optional Advanced Controls - iGate™ communicating
control provides advanced unit functionality and
comprehensive configuration, monitoring and
diagnostic capabilities through digital communication
links with the variable-speed fan motor, variable-speed
source pump (or modulating valve) and communicating
thermostat or Configuration/Diagnostic tool.
• 7 temperature sensor inputs for system protection
and control
• Anti-short cycle and over/under voltage protection
• High pressure, loss of charge, and condensate
overflow protection
• LED fault and status indication at controller
• Service tool port for optional setup and
diagnostics at unit
• Eight Safeties Standard.
• Filter Rail for 1" or 2" Filter
• LonWorks, BACnet, Modbus and Johnson N2
compatibility options for DDC controls
• Unit Performance Sentinel performance monitoring
system
• Integrated drain pan with condensate overflow sensor
• Attractive return air panel with hinged access door
(“G” panel) - option key locked.
• Multiple supply air discharge options
• Full port shut-off valves with memory stop, for supply
and return, located opposite return air panel inside
cabinet
Eng/I-P
• Stainless steel braided hose kits for connection from
piping risers to chassis
• Wide variety of cabinet options including disconnect
switch, breaker, thermostat whip with molex connector,
isolation pad, stainless steel drain pan, riser chase, and
ECM variable speed communicating and electric heat
motor.
• Wide variety of chassis options including stainless
steel drain pan, insulated tubing for extended
range operation, vFlowв„ў (modulating valve normally
closed or variable speed pump), autoflow regulator,
motorized water valve (normally closed), secondary
circulating pump, and cupro-nickel coaxial heat
exchanger
• Selection of thermostats including manual changeover,
automatic changeover, or programmable are available.
• Accessory Filters, 1" Merv 8 and 11; 2" Merv 8 and 13
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 5
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
iGateв„ў Communicating Controls
iGateв„ў Information gateway to monitor, control and
diagnose your system
TranquilityВ® Vertical Stack Series is equipped with
industry-first, iGate™ – Information Gateway – 2-way
communicating system that allows users to interact with
their water-source system in plain English AND delivers
improved reliability and efficiency by precisely controlling
smart variable speed components.
Monitor/Configure – Installers can configure from the
iGateв„ў communicating thermostat or configuration/
diagnostic tool, including: Air flow, loop delta T, waterflow option configuration, unit configuration, accessory
configuration, and demand reduction (optional, to limit
unit operation during peak times). Users can look up the
current system status: temperature sensor readings and
operational status of the blower and pump.
Precise Control – The new DXM2 board enables
intelligent, 2-way communication between the DXM2
board and smart components like the communicating
thermostat, fan motor, and water pump. The DXM2
control can also directly control the modulating valve and
accepts various feedback/input (see figure). The Intelligent
DXM2 board uses information received from the smart
components and sensors to precisely control operation
of variable speed fan, variable speed water pump (or
modulating valve) to deliver higher efficiency, reliability
and increased comfort.
Diagnostics – iGate™ takes diagnosing geothermal units
to a next level of simplicity, by providing a dashboard of
system and fault information, in plain English, on the iGate
thermostat/ service tool.
iGateв„ў Service Warning warns the occupant of a fault and
displays fault description, possible causes and current
system status (temperature readings, fan RPM and water
flow status) which may be reported to service personnel.
в„ў
In iGate Service Mode, the service personnel can access
fault description, possible causes and most importantly,
the conditions (temp, flow, i/o conditions, configuration)
at the time of the fault. Manual Operation mode allows
the service personnel to manually command operation for
any of the thermostat outputs, blower speed, as well as
pump speed or valve position from the thermostat, to help
troubleshoot specific components.
With iGateв„ў communicating system, users and contractors
have a gateway to system information never before
available.
ECM
Blower
Motor
Communicating
Thermostat
DXM2
Or
Sensors
Diagnostic
Tool
Two-Way Communication
One-Way Communication
Or
Mot.
Modulating
Valve
Variable
Speed
Pump
AIRFLOW SELECTION
HEAT STAGE 1
HEAT STAGE 2
AUXILIARY HEAT
EMERGENCY HEAT
COOL STAGE 1
COOL STAGE 2
COOL DEHUMID 1
COOL DEHUMID 2
CONTINUOUS FAN
HEAT OFF DELAY
COOL OFF DELAY
PREVIOUS
CFM
600
750
850
850
525
700
425
550
350
60
30
NEXT
POSSIBLE FAULT CAUSES
LOW WATER COIL TEMP
LOW WATER TEMP - HTG
LOW WATER FLOW - HTG
LOW REFRIG CHARGE - HTG
INCORRECT LT1 SETTING
BAD LT1 THERMISTOR
PREVIOUS
FAULT TEMPERATURE CONDITIONS
LT1 LOW WATER TEMP
HEAT 1 11:11 AM 11/14
LT1 TEMP
LT2 TEMP
HOT WATER EWT
COMP DISCHARGE
LEAVING AIR
LEAVING WATER
ENTERING WATER
CONTROL VOLTAGE
28.1
97.3
121.5
157.7
92.7
34.9
42.1
26.4
PREVIOUS
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 6
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
vFlowв„ў Internal Variable Water Flow Control
vFlowв„ў Internal Variable Water Flow
Industry-first, Built-in vFlowв„ў provide an ultra-highefficient, variable speed, internal water flow system. It
saves installers time and labor by avoiding installing
bulky external pumps, valves, or flow regulators. Multiunit installations are also much simpler with vFlowв„ў
systems, as the units automatically adjust water flow
across the system.
vFlowв„ў is enabled by iGateв„ў, which facilitates intelligent
communication between the thermostat, DXM2 control,
sensors and internal water pump/valve to make true
variable water flow a reality.
в„ў
vFlow is available in two variations:
1. Low System Pressure Drop Modulating Valve – High CV
motorized valve for central pumping.
2. Standard Head Variable Pump – multi unit/central pumping.
vFlowв„ў delivers three main benefits:
1. Easier and quicker unit installation as the flow control is built
in to the unit.
2. Superior reliability by varying the water flow to deliver more
stable operation across the entering water range (20°–120°F,
heating and cooling).
3. Higher cost savings by varying the flow (and pump watt
consumption) to match the unit’s mode of operation.
Variable flow
vFlowв„ў technology enables variable water flow through
the unit, with the DXM2 control adjusting the pump
speed to maintain an installer-set loop delta T. By
controlling the water flow, the system is able to operate
at its optimal capacity and efficiency. vFlowв„ў provides a
lower flow rate for part load where units typically operate
80% of the time and a higher, more normal flow rate for
full load operation.
Variable speed pump or motorized modulating
valve delivers variable water-flow, controlled
by DXM2 control, based on loop water ∆T.
Lowering the flow results in lower energy consumption by
the water pump (=higher cost savings) in vFlowв„ў units.
In applications using vFlowв„ў with internal variable-speed
(ECM) pump, the ECM pump uses fewer watts than a
fixed speed (PSC) pump, even at full load. The ECM
pump excels in energy savings in part load, saving 70
–80% watts compared to fixed speed pumps (see chart).
The ECM pump can operate with independent flow rates
for heating and cooling, further saving more energy.
In applications using vFlowв„ў with modulating valve,
when the motorized modulating valve slows down the
water flow during part load operation, the external pump
consumes fewer watts, thus saving more energy.
Energy Savings with water circulation control
Units with vFlowв„ў deliver higher operating cost savings
by varying the water flow to match the unit’s operation
(ex: lower water flow when unit is in part load operation).
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 7
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Selection Procedure
Reference Calculations
Heating
Cooling
HE
LWT = EWT GPM x Constant
LAT = EAT +
HC
CFM x1.08
LWT = EWT +
HE
GPM x Constant
LAT (DB) = EAT (DB) -
LC = TC - SC
SC
CFM x1.08
S/T =
SC
TC
Constant = 500 for water, 485 for antifreeze.
Legend and Glossary of Abbreviations
BTUH = BTU( British Thermal Unit) per hour
CFM = airflow, cubic feet/minute
COP = coefficient of performance = BTUH output/BTUH input
DB = dry bulb temperature (В°F)
EAT = entering air temperature, Fahrenheit (dry bulb/wet bulb)
EER = energy efficiency ratio = BTUH output/Watt input
MPT = male pipe thread
ESP = external static pressure (inches w.g.)
EWT = entering water temperature
GPM = water flow in U.S. gallons/minute
HE = total heat of extraction, BTUH
HC = air heating capacity, BTUH
HR = total heat of rejection, BTUH
HWC
FPT
KW
LAT
LC
LWT
MBTUH
S/T
SC
TC
WB
WPD
= hot water generator (desuperheater) capacity, Mbtuh
= female pipe thread
= total power unit input, kilowatts
= leaving air temperature, В°F
= latent cooling capacity, BTUH
= leaving water temperature, В°F
= 1000 BTU per hour
= sensible to total cooling ratio
= sensible cooling capacity, BTUH
= total cooling capacity, BTUH
= wet bulb temperature (В°F)
= waterside pressure drop (psi & ft. of hd.)
Conversion Table - to convert inch-pound (English) to S-I (Metric)
Air Flow
Water Flow
Ext Static Pressure
Water Pressure Drop
Airflow (L/s) = CFM x 0.472
Water Flow (L/s) = gpm x 0.0631
ESP (Pa) = ESP (in of wg) x 249
PD (kPa) = PD (ft of hd) x 2.99
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 8
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Selection Procedure
Step 1 Determine the actual heating and cooling loads at the
desired dry bulb and wet bulb conditions.
Example Equipment Selection For Cooling
Step 2 Obtain the following design parameters: Entering water
temperature, water flow rate in GPM, air flow in CFM,
water flow pressure drop and design wet and dry bulb
temperatures. Air flow CFM should be between 300 and
500 CFM per ton. Unit water pressure drop should be
kept as close as possible to each other to make water
balancing easier. Go to the appropriate tables and find
the proper indicated water flow and water temperature.
Assume we have determined that the appropriate cooling load
at the desired dry bulb 80В°F and wet bulb 65В°F conditions is
as follows
Step 3 Select a unit based on total and sensible cooling
conditions. Select a unit which is closest to, but no
larger than, the actual cooling load.
Step 4 Enter tables at the design water flow and water
temperature. Read the total and sensible cooling
capacities (Note: interpolation is permissible,
extrapolation is not).
Step 1 Load Determination:
Total Cooling........................................................17,000 BTUH
Sensible Cooling..................................................12,000 BTUH
Entering Air Temp..................80В°F Dry Bulb / 65В°F Wet Bulb
Step 2 Design Conditions:
Similarly, we have also obtained the following design parameters:
Entering Water Temp........................................................90В°F
Water Flow (Based upon 10В°F rise in temp.).............5.1 GPM
Air Flow at ESP Unit...........................630 CFM (90% of rated)
Step 3, 4 & 5 HP Selection:
Step 5 Read the heating capacity. If it exceeds the design
criteria it is acceptable. It is quite normal for WaterSource Heat Pumps to be selected on cooling capacity
only since the heating output is usually greater than the
cooling capacity.
Step 6 Determine the correction factors associated with the
variable factors of dry bulb, wet bulb, and air flow.
Corrected Total Cooling = tabulated total cooling x wet
bulb correction x air flow correction.
Corrected Sensible Cooling = tabulated sensible cooling
x wet/dry bulb correction, and air flow correction.
Step 7 Compare the corrected capacities to the load
requirements. Normally if the capacities are within 10%
of the loads, the equipment is acceptable. It is better
to undersize than oversize, as undersizing improves
humidity control, reduces sound levels and extends the
life of the equipment.
Step 8 When completed, calculate water temperature rise
and assess the selection. If the units selected are not
within 10% of the load calculations, then review what
effect changing the GPM, water temperature and/or air
flow and air temperature would have on the corrected
capacities. If the desired capacity cannot be achieved,
select the next larger or smaller unit and repeat the
procedure. Remember, when in doubt, undersize
slightly for best performance.
After making our preliminary selection (TSL18 with PSC motor),
we enter the tables at design water flow and water temperature
and read Total Cooling, Sens. Cooling and Heat of Rej.
capacities:
Total Cooling........................................................18,350 BTUH
Sensible Cooling..................................................13,210 BTUH
Heat of Rejection.................................................22,470 BTUH
Step 6 & 7 Entering Air and Airflow Corrections:
Next, we determine our correction factors.
Table
Ent Air
Air Flow
Corrected
Corrected Total Cooling = 18,350 x 0.975 x 0.971 = 17,372
Corrected Sens Cooling = 13,210 x 0.999 x 0.932 = 12,299
Corrected Heat of Reject = 22,470 x 0.982 x 0.979 = 21,602
Step 8 Water Temperature Rise Calculation & Assessment:
Actual Temperature Rise..................................................8.8В°F
When we compare the Corrected Total Cooling and Corrected
Sensible Cooling figures with our load requirements stated
in Step 1, we discover that our selection is within +/- 10%
of our sensible load requirement. Furthermore, we see that
our Corrected Total Cooling figure is slightly undersized as
recommended, when compared to the actual indicated load.
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 9
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
TSL Series Nomenclature
Cabinet
1
2
3
D1 G
4
5
0
N
11
12
13
14
15
0 E 1 0 0 0
0
0
0
A
6
7
8
10
9
REVISION LEVEL
CABINET SIZE
A = CURRENT REVISION
1 = 09
2 = 12
3 = 15
4 = 18
5 = 24
6 = 30
7 = 36
STANDARD
0 = STANDARD
A, B, C etc.... = SPECIAL 1, 2, 3 etc....
T-STAT WHIP
0 = No Whip
1 = 15’ whip
2 = 25’ whip
3 = 35’ whip
VOLTAGE
OPTION
Volt/Hertz/Phaze
G
E
208-230/60/1
265/60/1
N/A
OPTIONS
0 = No Opening
OPTION S.S. DRAIN PAN PREMIUM SEAL
–
X
X
–
–
X
X
–
A
B
C
0
1
2
3
4
1Гќ and 2Гќ FILTER
1Гќ
1Гќ
1Гќ
1Гќ
2Гќ
2Гќ
2Гќ
2Гќ
X
–
X
–
X
–
X
–
Discharge Air
3 = Top Opening
NOT USED
HARNESS CONTROLS
LOW
OPTION PSC STATIC ECM
PSC
A
B
C
D
L
M
N
R
T
U
V
–
–
–
–
–
–
–
–
X
X
X
X
–
X
–
X
–
X
–
–
–
–
0 = Not Used
R =REMOTE
M = MPC
W = WALL SENSOR L = LON
A = ADA
–
X
–
X
–
X
–
X
–
–
–
RISER: LOCATION
–
–
M
M
L
L
–
–
–
M
–
A
A
W
W
W
W
R
R
A
W
R
0 = None
1 = Shipped Separately
6 = Chassis ships in Cabinet (Risers Not Attached)
RISER STYLE
0 = SLAVE / NONE
1 = STANDARD
2 = MASTER
CABINET HEIGHT
POWER TERMINATION
OPTION DISCONNECT SWITCH
A
B
C
0
BREAKER
ISP / BREAKER
X
OPTION
65”
E
F
X
X
ISO PAD
X
X
X
NO OPTIONS
Note: Risers always ship separate.
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 10
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
TSL Series Nomenclature
Chassis
3
4 5
6
7
8
9
10
11
12
13
TSL
09
G
S
A
S
S
C
S
S S A
1 2
15
14
Revision Level
Series
A = Current Revision Level
TSL = TRANQUILITYВ®
HIGH RISE CHASSIS
For D (65”) Cabinet
Standard
S = Standard
A = Special #1
B = Special #2
Etc.....
Unit Size
09
12
15
18
24
30
36
Future Use
S = Standard
Shipping
6 = Chassis Will Ship In Cabinet (Risers Not Attached)
S = Standard
Voltage
E = 265/60/1
G = 208-230/60/1
Heat Exchanger Options
Tin Plated Air Coil
Position 11
Chassis Options
A
S.S.
Drain
Pan
X
B
–
X
C
S
X
–
X
–
OPTION
Non-Coated Air Coil
Copper
Cupro-nickel
Copper
Cupro-nickel
Standard Tubing
C
N
L
M
Insulated Tubing
(Extended Range)
D
E
F
G
Water Valve & Pump Option
ULTRAQUIET
S = No Water valve
M = Standard Water Valve (Normally Closed)
P = Secondary Circulating Pump
T = Modulating Valve
U = UPM-Geo
–
Controls
A = CXM w/PSC
B = DXM2 w/ECM
C = DXM2 w/PSC
1 = CXM w/PSC w/EH
2 = DXM2 w/ECM w/EH
3 = DXM2 w/PSC w/EH
Chassis
Cabinet
09
D1
12
D2
15
D3
18
D4
24
D5
30
D6
36
D7
AUTO-FLOW REGULATOR (US GPM) CODE
7/8 SWEAT
5/8 SWEAT
UNIT
09
1.5
UNIT
12
2.0
UNIT
15
-
UNIT
18
-
UNIT
24
C
D 2.0
2.5
2.5
E 2.5
3.0
3.0
3.0
F 3.0
3.5
3.5
3.5
G
4.0
4.0
4.0
H
J
5.0
5.0
6.0
K
L
7.0
M N
P
S = STANDARD - NO FLOW REGULATOR
UNIT
30
-
UNIT
36
-
-
-
-
-
5.0
6.0
6.0
7.0
8.0
-
-
7.0
8.0
9.0
10.0
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 11
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
TSL Series Nomenclature
Hose Kit
1 2 3
4
5
6
7
8
AH H 0 5 0 3 B
Group
Revision Level
B = Current Revision
AHH = Accessory Hose Kit Hi-Rise
Hose Size
Length
050 = 1/2” Nominal
075 = 3/4” Nominal
100 = 1” Nominal
3 = Length in Feet
Return Air Panel
1
2
3
4
5
7
6
8
9
10
11
F S M S
AVHSG 1 S
STANDARD
S = STANDARD
ACCESSORY VHS RETURN AIR PANEL
AVHSG = G-PANEL
REVISION LEVEL
M = CURRENT REVISION TSM/TSL (”G” PANEL)
UNIT SIZE
OPTION
1
2
3
TSM/TSL
STYLE
09, 12, 15, 18
N/A
24, 30, 36
A = DOOR w/ADA TSTAT MOUNTING
B = DOOR w/ADA TSTAT MOUNTING & GRILLE
C = DOOR w/ADA TSTAT MOUNTING & LOCK
D = DOOR w/ADA TSTAT MOUNTING, GRILLE, & LOCK
G = DOOR w/GRILLE (20 GA. SHEET METAL) 24-36
K = DOOR w/KEY LOCKS & GRILLE (18 GA. SHEET METAL)
L = DOOR w/KEY LOCKS (18 GA. SHEET METAL)
S = STANDARD (20 GA. SHEET METAL)
COLOR
N = NON-PAINTED
S = STANDARD (POLAR ICE)
INSULATION TYPE
B = FOIL-BACK
F = FIBERGLASS
Cabinet Stand
1 2 3 4
5
6 7
8
9
10
11
12
13
1 01 0 0 0 0 0 A
A CS T
Accessory Cabinet Stand TSM/TSL
REVISION
A=CURRENT REVISION
UNIT SIZE
FUTURE USE
1 = 09-18
2 = 24-36
0 = STANDARD
HEIGHT
01 = 1”
02 = 2”
03 = 3”
04 = 4”
05 = 5”
06 = 6”
07 = 7”
08 = 8”
09 = 9”
10 = 10”
11 = 11”
12 = 12”
FUTURE USE
0 = STANDARD
FUTURE USE
0 = STANDARD
FUTURE USE
0 = STANDARD
ISO PAD
0 = STANDARD (NO ISO PAD)
1 = ISO PAD
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 12
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Performance Data – AHRI/ASHRAE/ISO 13256-1
ASHRAE/AHRI/ISO 13256-1. English (I-P) Units
Water Loop Heat Pump
Model
with ECM
Motor
TSL09
Cooling 86В°F
Ground Water Heat Pump
Heating 68В°F
Capacity
Btuh
EER
Btuh/W
Capacity
Btuh
10,000
15.2
13,100
Cooling 59В°F
Ground Loop Heat Pump
Heating 50В°F
COP
Capacity
Btuh
EER
Btuh/W
Capacity
Btuh
5.4
11,800
24.8
10,400
Cooling 77В°F
Heating 32В°F
COP
Capacity
Btuh
EER
Btuh/W
Capacity
Btuh
COP
4.4
10,400
17.3
7,500
3.3
TSL12
11,600
14.9
15,800
5.1
13,600
24.2
12,900
4.2
12,500
17.5
9,400
3.3
TSL15
14,600
16.3
18,900
5.4
16,800
25.8
15,000
4.6
15,400
19.2
11,000
3.7
TSL18
17,100
15.1
22,300
5.4
20,300
24.6
17,700
4.6
18,400
17.8
13,000
3.5
TSL24
25,000
16.4
30,500
5.3
29,000
27.2
25,000
4.6
26,500
19.4
18,500
3.6
TSL30
28,500
16.1
33,500
5.3
32,500
24.7
27,500
4.7
29,500
18.4
21,000
3.7
TSL36
37,500
14.8
44,000
5.0
42,500
22.6
36,000
4.3
38,500
16.7
28,000
3.5
Water Loop Heat Pump
Model
with PSC
Motor
Cooling 86В°F
Ground Water Heat Pump
Heating 68В°F
Capacity
Btuh
EER
Btuh/W
Capacity
Btuh
COP
TSL09
9,500
14.1
13,000
TSL12
11,600
14.3
15,900
TSL15
14,000
14.3
TSL18
16,800
TSL24
Cooling 59В°F
Ground Loop Heat Pump
Heating 50В°F
Capacity
Btuh
EER
Btuh/W
Capacity
Btuh
5.0
11,300
22.5
4.7
13,500
22.9
19,000
5.0
17,500
13.2
22,800
5.0
24,500
15.2
31,500
TSL30
28,000
15.2
TSL36
34,500
14.3
Cooling 77В°F
Heating 32В°F
COP
Capacity
Btuh
EER
Btuh/W
Capacity
Btuh
COP
10,400
4.2
10,000
16.0
7,500
3.2
13,000
4.1
12,122
16.4
9,629
3.2
25.8
15,500
4.8
15,400
17.7
11,500
3.6
19,900
20.6
18,400
4.2
18,600
16.9
13,100
3.4
5.0
28,500
24.3
25,500
4.3
26,000
17.9
18,500
3.4
34,000
5.2
32,000
23.7
27,000
4.4
29,500
18.0
21,000
3.4
41,500
5.0
38,500
22.0
33,500
4.3
36,000
16.6
25,500
3.5
Cooling capacities based upon 80.6В°F DB, 66.2В°F WB entering air temperature
Heating capacities based upon 68В°F DB, 59В°F WB entering air temperature
All units AHRI/ISO/ASHRAE 13256-1 rated on high speed motor TAP
All ratings based upon operation at lower voltage of dual voltage rated models
ASHRAE/AHRI/ISO 13256-1. Metric (S-I) Units
Water Loop Heat Pump
Model
with ECM
Motor
Cooling 30В°C
Ground Water Heat Pump
Heating 20В°C
Capacity
kW
EER
W/W
Capacity
kW
TSL09
2.93
4.5
TSL12
3.40
TSL15
4.28
TSL18
Cooling 15В°C
COP
Capacity
kW
EER
W/W
Capacity
kW
3.84
5.4
3.46
7.3
4.4
4.63
5.1
3.99
4.8
5.54
5.4
4.92
5.01
4.4
6.54
5.4
TSL24
7.33
4.8
8.94
TSL30
8.35
4.7
TSL36
10.99
4.3
Cooling 30В°C
Cooling 25В°C
Heating 0В°C
COP
Capacity
kW
EER
W/W
Capacity
kW
COP
3.05
4.4
3.05
5.1
2.20
3.3
7.1
3.78
4.2
3.66
5.1
2.75
3.3
7.6
4.40
4.6
4.51
5.6
3.22
3.7
5.95
7.2
5.19
4.6
5.39
5.2
3.81
3.5
5.3
8.50
8.0
7.33
4.6
7.77
5.7
5.42
3.6
9.82
5.3
9.53
7.2
8.06
4.7
8.65
5.4
6.15
3.7
12.90
5.0
12.46
6.6
10.55
4.3
11.28
4.9
8.21
3.5
Water Loop Heat Pump
Model
with PSC
Motor
Ground Loop Heat Pump
Heating 10В°C
Ground Water Heat Pump
Heating 20В°C
Capacity
kW
EER
W/W
Capacity
kW
TSL09
2.78
4.1
TSL12
3.40
4.2
TSL15
4.10
TSL18
Cooling 15В°C
Ground Loop Heat Pump
Heating 10В°C
COP
Capacity
kW
EER
W/W
Capacity
kW
3.81
5.0
3.31
6.6
4.66
4.7
3.96
6.7
4.2
5.57
5.0
5.13
4.92
3.9
6.68
5.0
TSL24
7.18
4.5
9.23
TSL30
8.21
4.5
TSL36
10.11
4.2
Cooling 25В°C
Heating 0В°C
COP
Capacity
kW
EER
W/W
Capacity
kW
COP
3.05
4.2
2.93
4.7
2.20
3.2
3.81
4.1
3.55
4.8
2.82
3.2
7.6
4.54
4.8
4.51
5.2
3.37
3.6
5.83
6.0
5.39
4.2
5.45
5.0
3.84
3.4
5.0
8.35
7.1
7.47
4.3
7.62
5.2
5.42
3.4
9.96
5.2
9.38
6.9
7.91
4.4
8.65
5.3
6.15
3.4
12.16
5.0
11.28
6.4
9.82
4.3
10.55
4.9
7.47
3.5
Cooling capacities based upon 27В°C DB, 19В°C WB entering air temperature
Heating capacities based upon 20В°C DB, 15В°C WB entering air temperature
All units AHRI/ISO/ASHRAE 13256-1 rated on high speed motor TAP
All ratings based upon operation at lower voltage of dual voltage rated models
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 13
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Performance Data – Selection Notes
For operation in the shaded area to determine if water
can be used in lieu of an antifreeze solution, the Leaving
Water Temperature (LWT) must be calculated. Flow must be
maintained to a level such that the LWT is maintained above
42В°F [5.6В°C] when the CXM/DXM2 JW3 jumper is not clipped
(see example below). Otherwise, appropriate levels (10В° below
LWT, See IOM) of a proper antifreeze should be used in systems
with leaving water temperatures of 42В°F [5.6В°C] or below and
the JW3 jumper should be clipped. This is due to the potential
of the refrigerant temperature being as low as 32В°F [0В°C], which
may lead to a nuisance cutout due to the activation of the Low
Temperature Protection (LT1). JW3 should never be clipped for
standard range equipment or systems without antifreeze.
Example:
/67В°F
W
Heating - EAT 70В°F
HR
EER
HC
kW
HE
LAT
COP
23.28
2.31
15.72
85.9
3.0
mended
62
52.07
29.0
26.08
2.35
18.36
88.1
3.2
51
52.26
31.3
27.35
2.37
19.56
89.1
3.4
47
52.27
32.5
28.06
2.38
20.23
89.6
3.4
77
51.56
26.0
30.51
2.42
22.56
91.5
3.7
65
51.98
28.3
32.12
2.45
24.08
92.7
3.8
At 50В°F EWT (Entering Water Temperature) and 1.5 gpm/ton, a
3 ton unit has a HE of 26,830 Btuh. To calculate LWT, rearrange
the formula for HE as follows:
60
52.12
29.4
33.01
2.46
24.92
93.4
3.9
94
50.82
22.9
35.03
2.49
26.83
95.0
4.1
80
51.40
25.3
36.94
2.52
28.65
96.4
4.3
HE = TD x GPM x 500, where HE = Heat of Extraction (Btuh);
TD = temperature difference (EWT - LWT) and GPM = U.S.
Gallons per Minute.
74
51.65
26.4
38.00
2.54
29.65
97.3
4.4
5
49.89
19.9
39.53
2.56
31.09
98.4
4.5
TD = HE / (GPM x 500)
TD = 26,830 / (4.5 x 500)
TD = 12В°F
LWT = EWT - TD
LWT = 50 - 12 = 38В°F - Requires appropriate antifreeze (Protect to 28В°F), JW3 must be clipped, and extended range insulation
option.
In this example, a higher flow rate will be required for EWTs of 50В°F without antifreeze. At 3 gpm/ton, the calculation becomes:
(Note higher flow increases HE)
TD = 29,650 / (9GPMx500)
TD = 7В°F
LWT = 50 - 7 = 43В°F - Water is acceptable, do not clip JW3.
Performance Data Selection Notes – vFlow™ Models
Operation in Shaded Area: Closed Loop Application
For operation in the shaded area, appropriate levels of a proper antifreeze should be used in systems with leaving water
temperatures of 40В°F or below and the JW3 jumper should be clipped. This is due to the potential of the refrigerant temperature
being as low as 32В°F [0В°C] with 40В°F [4.4В°C] LWT, which may lead to a nuisance cutout due to the activation of the Low Temperature
Protection. JW3 should never be clipped for systems without antifreeze.
Open Loop Application:
For operation in shaded area (below 40°F LWT) in open loop applications, ΔT (on DXM2) should be set such that the LWT (=EWT ΔT) doesn’t drop below 40°F. JW3 should NEVER be clipped for systems without antifreeze.
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 14
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Performance Data – TSL09 with PSC Motor
400 CFM Nominal Airflow Heating, 350 CFM Nominal Airlfow Cooling
*WPD Adder for
Motorized Valve,
TSL09
(Cv = 4.9,
MOPD = 150 psi)
WPD Adder
EWT
В°F
20
GPM
PSI
FT
1.5
0.3
0.7
2.3
0.5
1.1
3.0
0.6
30
1.4
40
50
WPD*
GPM
PSI
70
80
90
100
110
120
TC
Heating - EAT 70В°F
EER
HC
kW
HE
LAT
COP
1.5
1.6
2.3
1.8
3.0
5.7
13.2
6.33
0.65
3.96
75.6
2.8
1.5
1.1
2.6
13.08
9.05
0.69
0.41
14.61
32.5
7.36
0.66
4.95
76.9
3.2
2.3
1.8
4.0
12.95
8.80
0.68
0.39
14.43
33.4
7.70
0.67
5.28
77.3
3.3
3.0
4.7
10.7
12.82
8.63
0.67
0.39
14.29
33.5
7.89
0.67
5.46
77.5
3.4
1.5
0.8
1.9
12.97
9.21
0.71
0.44
14.64
29.6
8.84
0.68
6.39
78.7
3.8
2.3
1.7
3.9
13.08
9.14
0.70
0.42
14.65
31.6
9.31
0.68
6.84
79.3
3.9
9.06
0.69
0.41
14.62
32.4
Operation not recommended
3.0
4.1
9.6
13.08
9.57
0.68
7.09
79.6
4.0
1.5
0.5
1.1
12.59
9.16
0.73
0.49
14.42
25.9
10.39
0.69
7.89
80.6
4.4
2.3
1.6
3.7
12.87
9.21
0.72
0.46
14.58
28.3
10.98
0.69
8.47
81.3
4.6
3.0
3.6
8.4
12.97
9.21
0.71
0.44
14.63
29.5
11.31
0.69
8.79
81.7
4.7
1.0
12.00
8.95
0.75
0.55
14.03
22.1
11.95
0.70
9.42
82.5
5.0
9.09
0.73
0.51
14.29
24.5
1.5
60
FT
Performance capacities shown in thousands of Btuh
Cooling - EAT 80/67В°F
Sens/Tot
SC
kW
HR
Ratio
0.4
2.3
1.5
3.5
12.40
12.65
0.70
10.11
83.4
5.2
3.0
4.0
9.3
12.57
9.15
0.73
0.49
14.41
25.8
13.04
0.70
10.49
83.9
5.4
8.64
0.77
0.61
13.52
18.6
1.5
0.4
0.9
11.28
13.50
0.71
10.94
84.4
5.5
2.3
1.4
3.3
11.74
8.84
0.75
0.57
13.84
20.7
14.28
0.71
11.71
85.4
5.8
8.93
0.75
0.55
14.00
21.9
3.0
3.0
7.0
11.96
14.71
0.71
12.13
85.9
6.0
1.5
0.3
0.8
10.46
8.27
0.79
0.68
12.94
15.6
14.98
0.71
12.40
86.3
6.1
8.49
0.78
0.64
13.29
17.3
2.3
1.3
3.1
10.95
15.81
0.72
13.22
87.3
6.4
3.0
3.1
7.1
11.20
8.60
0.77
0.62
13.46
18.3
16.24
0.72
13.65
87.8
6.6
7.87
0.82
0.75
12.33
12.9
1.5
0.3
0.7
9.61
16.36
0.72
13.76
88.0
6.6
2.3
1.5
3.5
10.09
8.10
0.80
0.71
12.68
14.4
17.18
0.72
14.57
89.0
6.9
8.21
0.79
0.69
12.86
15.2
17.58
0.72
14.98
89.5
7.1
3.0
3.1
7.2
10.34
1.5
0.1
0.2
8.76
7.49
0.86
0.83
11.73
10.8
2.3
1.2
2.9
9.21
7.69
0.84
0.79
12.05
11.9
3.0
2.8
6.4
9.45
7.80
0.83
0.77
12.22
12.5
1.5
0.1
0.2
7.96
7.16
0.90
0.90
11.18
9.0
2.3
1.2
2.8
8.36
7.32
0.88
0.86
11.45
9.9
7.41
0.86
0.84
11.60
10.3
3.0
2.7
6.2
8.57
1.5
0.1
0.2
7.26
6.93
0.95
0.97
10.72
7.6
7.03
0.93
0.94
10.93
8.3
7.09
0.91
0.92
11.05
8.6
2.3
1.2
2.7
7.59
3.0
2.6
6.0
7.77
Operation not recommended
Interpolation is permissible; extrapolation is not.
All entering air conditions are 80В°F DB and 67В°F WB in cooling, and 70В°F DB in heating.
AHRI/ISO certified conditions are 80.6В°F DB and 66.2В°F WB in cooling and 68В°F DB in heating.
Table does not reflect fan or pump power corrections for AHRI/ISO conditions.
All performance is based upon the lower voltage of dual voltage rated units.
Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated.
Operation below 40В°F EWT is based upon a 15% methanol antifreeze solution.
Operation below 60В°F EWT requires optional insulated water/refrigerant circuit.
See performance correction tables for operating conditions other than those listed above.
See Performance Data Selection Notes for operation in the shaded areas.
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 15
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Performance Data – TSL12 with PSC Motor
500 CFM Nominal Airflow Heating, 400 CFM Nominal Airlfow Cooling
WPD*
EWT
В°F
20
30
40
50
60
70
80
90
100
110
120
GPM
PSI
FT
1.8
4.1
2.6
6.3
3.5
9.4
21.7
1.8
3.4
7.9
Performance capacities shown in thousands of Btuh
Cooling - EAT 80/67В°F
TC
SC
Sens/Tot
Ratio
kW
Heating - EAT 70В°F
HR
EER
HC
kW
HE
LAT
COP
WPD Adder
Operation not recommended
15.44
9.92
0.64
0.45
16.96
*WPD Adder for
Motorized Valve,
TSL12
(Cv = 4.9,
MOPD = 150 psi)
GPM
34.6
8.00
0.79
5.31
82.8
3.0
9.12
0.81
6.36
84.9
3.3
2.6
5.6
13.0
15.49
9.88
0.64
0.41
16.89
37.6
9.56
0.82
6.77
85.7
3.4
3.5
7.8
18.0
15.46
9.83
0.64
0.40
16.81
39.0
9.81
0.82
7.00
86.1
3.5
1.8
2.9
6.6
15.13
9.86
0.65
0.51
16.86
29.9
10.87
0.84
8.01
88.1
3.8
2.6
4.9
11.4
15.36
9.92
0.65
0.47
16.95
32.9
11.47
0.85
8.57
89.2
4.0
3.5
6.2
14.4
15.44
9.92
0.64
0.45
16.96
34.5
11.81
0.85
8.89
89.8
4.0
1.8
2.3
5.3
14.59
9.65
0.66
0.57
16.55
25.4
12.73
0.87
9.77
91.5
4.3
2.6
4.2
9.8
14.96
9.80
0.65
0.53
16.77
28.2
13.49
0.88
10.49
92.9
4.5
3.5
7.7
17.8
15.11
9.85
0.65
0.51
16.85
29.7
13.92
0.88
10.90
93.7
4.6
1.8
2.3
5.3
13.89
9.35
0.67
0.65
16.10
21.4
14.64
0.89
11.59
95.1
4.8
2.6
4.1
9.5
14.34
9.55
0.67
0.60
16.40
23.8
15.55
0.90
12.47
96.7
5.0
3.5
5.9
13.6
14.56
9.64
0.66
0.58
16.53
25.1
16.07
0.91
12.96
97.7
5.2
1.8
2.2
5.2
13.07
8.97
0.69
0.73
15.56
17.9
16.56
0.92
13.44
98.6
5.3
2.6
4.0
9.1
13.57
9.21
0.68
0.68
15.90
19.9
17.61
0.93
14.44
100.5
5.6
3.5
6.2
14.3
13.82
9.32
0.67
0.66
16.06
21.1
18.19
0.93
15.00
101.6
5.7
1.8
2.1
4.9
12.17
8.54
0.70
0.81
14.95
15.0
18.45
0.94
15.26
102.1
5.8
2.6
3.9
8.9
12.70
8.80
0.69
0.76
15.31
16.6
19.59
0.95
16.36
104.2
6.1
3.5
5.6
13.0
12.97
8.93
0.69
0.74
15.49
17.5
20.20
0.95
16.96
105.3
6.2
1.8
2.1
4.8
11.25
8.09
0.72
0.90
14.33
12.5
20.26
0.95
17.01
105.4
6.2
2.6
3.7
8.7
11.77
8.34
0.71
0.85
14.68
13.8
21.43
0.96
18.15
107.6
6.5
3.5
5.5
12.7
12.04
8.48
0.70
0.83
14.86
14.5
22.04
0.97
18.75
108.7
6.7
1.8
1.9
4.4
10.34
7.63
0.74
1.00
13.73
10.4
2.6
3.4
7.8
10.82
7.87
0.73
0.95
14.05
11.4
3.5
5.4
12.4
11.08
8.00
0.72
0.92
14.22
12.0
1.8
1.8
4.2
9.48
7.19
0.76
1.09
13.20
8.7
2.6
3.3
7.7
9.91
7.41
0.75
1.04
13.46
9.5
3.5
5.3
12.2
10.14
7.53
0.74
1.02
13.61
10.0
1.8
1.8
4.1
8.71
6.82
0.78
1.19
12.76
7.3
2.6
3.3
7.5
9.07
6.99
0.77
1.14
12.96
8.0
3.5
5.2
11.9
9.27
7.09
0.76
1.11
13.08
8.3
PSI
FT
1.8
0.4
0.8
2.6
0.5
1.2
3.5
0.7
1.7
Operation not recommended
Interpolation is permissible; extrapolation is not.
All entering air conditions are 80В°F DB and 67В°F WB in cooling, and 70В°F DB in heating.
AHRI/ISO certified conditions are 80.6В°F DB and 66.2В°F WB in cooling and 68В°F DB in heating.
Table does not reflect fan or pump power corrections for AHRI/ISO conditions.
All performance is based upon the lower voltage of dual voltage rated units.
Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated.
Operation below 40В°F EWT is based upon a 15% methanol antifreeze solution.
Operation below 60В°F EWT requires optional insulated water/refrigerant circuit.
See performance correction tables for operating conditions other than those listed above.
See Performance Data Selection Notes for operation in the shaded areas.
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 16
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Performance Data – TSL15 with PSC Motor
600 CFM Nominal (Rated) Airflow
*WPD Adder for
Motorized Valve,
TSL15
(Cv = 10.3,
MOPD = 150 psi)
EWT
В°F
GPM
PSI
FT
Cooling - EAT 80/67В°F
TC
SC
Sens/Tot
Ratio
kW
Heating - EAT 70В°F
HR
EER
HC
kW
HE
LAT
COP
2.3
2.4
3.5
5.8
FT
4.5
8.8
20.3
8.99
0.98
6.15
81.8
2.7
2.3
2.3
5.4
17.43
11.10
0.64
0.65
19.15
26.6
10.44
1.01
7.51
84.1
3.0
3.5
5.0
11.6
16.92
10.50
0.62
0.63
18.56
26.9
10.91
1.02
7.95
84.8
3.1
4.5
8.3
19.2
16.60
10.17
0.61
0.62
18.20
26.9
11.16
1.02
8.19
85.2
3.2
2.3
2.2
5.1
17.82
11.84
0.66
0.72
19.75
24.9
12.41
1.04
9.37
87.1
3.5
3.5
4.3
9.8
17.67
11.46
0.65
0.68
19.47
26.0
12.98
1.05
9.91
88.0
3.6
4.5
7.7
17.8
17.52
11.23
0.64
0.66
19.27
26.5
13.29
1.05
10.21
88.5
3.7
2.3
2.1
4.8
17.69
12.22
0.69
0.79
19.87
22.4
14.34
1.07
11.20
90.1
3.9
3.5
4.2
9.7
17.82
12.04
0.68
0.74
19.85
23.9
15.01
1.08
11.84
91.1
4.1
4.5
7.1
16.4
17.83
11.91
0.67
0.72
19.79
24.6
15.38
1.09
12.18
91.7
4.2
2.3
2.1
4.9
17.17
12.30
0.72
0.88
19.64
19.6
16.24
1.10
13.01
93.0
4.3
3.5
4.2
9.7
17.52
12.29
0.70
0.82
19.81
21.3
17.00
1.11
13.73
94.2
4.5
4.5
7.0
16.1
17.65
12.24
0.69
0.80
19.86
22.1
17.41
1.11
14.12
94.8
4.6
2.3
2.0
4.7
16.36
12.13
0.74
0.97
19.16
16.9
18.09
1.12
14.78
95.9
4.7
3.5
4.2
9.6
16.85
12.26
0.73
0.91
19.46
18.4
18.93
1.13
15.58
97.1
4.9
4.5
6.9
15.8
17.08
12.29
0.72
0.89
19.59
19.3
19.38
1.14
16.01
97.8
5.0
2.3
2.0
4.5
15.34
11.77
0.77
1.07
18.49
14.3
19.89
1.14
16.51
98.6
5.1
3.5
4.0
9.2
15.93
11.99
0.75
1.01
18.88
15.7
20.80
1.15
17.39
100.0
5.3
4.5
6.6
15.3
16.21
12.09
0.75
0.98
19.06
16.5
21.28
1.15
17.85
100.8
5.4
2.3
1.9
4.4
14.19
11.25
0.79
1.18
17.71
12.0
21.63
1.16
18.20
101.3
5.5
3.5
3.9
9.0
14.82
11.55
0.78
1.12
18.14
13.2
22.59
1.16
19.14
102.8
5.7
4.5
6.6
15.3
15.14
11.68
0.77
1.09
18.35
13.9
23.10
1.16
19.64
103.6
5.8
2.3
1.9
4.4
12.97
10.63
0.82
1.30
16.89
10.0
3.5
3.9
8.9
13.61
10.96
0.81
1.24
17.31
11.0
4.5
6.5
15.0
13.93
11.12
0.80
1.21
17.53
11.5
2.3
1.9
4.4
11.74
9.95
0.85
1.42
16.06
8.3
3.5
3.9
8.9
12.34
10.28
0.83
1.36
16.46
9.1
4.5
6.4
14.8
12.65
10.46
0.83
1.33
16.67
9.5
2.3
1.9
4.4
10.56
9.25
0.88
1.54
15.30
6.9
3.5
3.8
8.8
11.10
9.57
0.86
1.48
15.64
7.5
4.5
6.3
14.6
11.38
9.74
0.86
1.45
15.83
7.8
WPD Adder
20
GPM
PSI
Performance capacities shown in thousands of Btuh
WPD*
2.3
0.2
0.5
3.5
0.3
0.8
4.5
0.4
1.1
30
40
50
60
70
80
90
100
110
120
Operation not recommended
Operation not recommended
Interpolation is permissible; extrapolation is not.
All entering air conditions are 80В°F DB and 67В°F WB in cooling, and 70В°F DB in heating.
AHRI/ISO certified conditions are 80.6В°F DB and 66.2В°F WB in cooling and 68В°F DB in heating.
Table does not reflect fan or pump power corrections for AHRI/ISO conditions.
All performance is based upon the lower voltage of dual voltage rated units.
Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated.
Operation below 40В°F EWT is based upon a 15% methanol antifreeze solution.
Operation below 60В°F EWT requires optional insulated water/refrigerant circuit.
See performance correction tables for operating conditions other than those listed above.
See Performance Data Selection Notes for operation in the shaded areas.
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 17
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Performance Data – TSL18 with PSC Motor
685 CFM Nominal (Rated) Airflow
Performance capacities shown in thousands of Btuh
WPD*
EWT
В°F
20
30
40
50
60
70
80
90
100
110
120
Cooling - EAT 80/67В°F
GPM
PSI
FT
TC
SC
Sens/Tot
Ratio
kW
Heating - EAT 70В°F
HR
3.4
2.6
5.1
4.7
6.8
7.2
16.7
3.4
2.2
5.1
23.79
15.72
0.66
0.77
25.90
5.1
4.2
9.7
23.88
15.52
0.65
0.73
6.8
6.7
15.4
23.89
15.38
0.64
3.4
1.9
4.3
23.35
15.80
5.1
3.8
8.7
23.61
6.8
5.4
12.5
3.4
1.5
3.5
5.1
3.3
6.8
4.4
3.4
1.5
5.1
2.9
6.8
3.4
EER
HC
kW
HE
LAT
COP
*WPD Adder for
Motorized Valve,
TSL18
(Cv = 10.3,
MOPD = 150 psi)
WPD Adder
Operation not recommended
GPM
10.67
1.18
7.16
82.1
2.7
31.0
12.64
1.21
9.01
84.7
3.1
25.85
32.8
13.10
1.22
9.45
85.3
3.1
0.71
25.79
33.7
13.36
1.23
9.69
85.6
3.2
0.68
0.85
25.75
27.3
15.18
1.26
11.41
88.0
3.5
15.81
0.67
0.81
25.86
29.2
15.79
1.27
11.98
88.8
3.7
23.71
15.77
0.67
0.79
25.89
30.1
16.12
1.27
12.29
89.3
3.7
22.61
15.55
0.69
0.95
25.33
23.8
17.78
1.30
13.87
91.5
4.0
7.7
23.01
15.71
0.68
0.90
25.57
25.6
18.53
1.31
14.57
92.5
4.1
10.0
23.19
15.76
0.68
0.88
25.67
26.5
18.93
1.31
14.96
93.0
4.2
3.3
21.63
15.06
0.70
1.05
24.70
20.6
20.40
1.34
16.36
94.9
4.5
6.6
22.13
15.32
0.69
1.00
25.03
22.1
21.29
1.35
17.20
96.1
4.6
4.3
9.9
22.37
15.44
0.69
0.97
25.19
23.0
21.77
1.36
17.66
96.7
4.7
1.4
3.2
20.45
14.40
0.70
1.16
23.91
17.6
23.04
1.37
18.87
98.4
4.9
5.1
2.4
5.5
21.03
14.73
0.70
1.11
24.30
19.0
24.07
1.39
19.85
99.8
5.1
6.8
4.2
9.6
21.31
14.89
0.70
1.08
24.49
19.7
24.62
1.39
20.38
100.5
5.2
3.4
1.1
2.4
19.13
13.65
0.71
1.29
23.01
14.9
25.68
1.41
21.38
101.9
5.3
5.1
2.6
6.0
19.75
14.01
0.71
1.23
23.43
16.1
26.83
1.42
22.49
103.4
5.5
6.8
4.1
9.5
20.06
14.18
0.71
1.20
23.65
16.7
27.45
1.43
23.08
104.2
5.6
3.4
1.1
2.5
17.71
12.86
0.73
1.42
22.04
12.5
28.29
1.44
23.89
105.3
5.8
5.1
2.8
6.6
18.35
13.21
0.72
1.36
22.47
13.5
29.56
1.45
25.11
107.0
6.0
6.8
4.0
9.3
18.67
13.39
0.72
1.33
22.69
14.0
30.24
1.46
25.76
107.9
6.1
3.4
1.1
2.5
16.22
12.07
0.74
1.56
21.04
10.4
5.1
2.2
5.0
16.85
12.40
0.74
1.50
21.46
11.2
6.8
3.6
8.4
17.17
12.57
0.73
1.47
21.68
11.7
3.4
1.0
2.2
14.70
11.30
0.77
1.72
20.06
8.5
5.1
2.1
4.9
15.31
11.60
0.76
1.66
20.45
9.2
6.8
3.5
8.2
15.62
11.76
0.75
1.62
20.65
9.6
3.4
1.0
2.2
13.19
10.58
0.80
1.89
19.13
7.0
5.1
2.1
4.7
13.76
10.85
0.79
1.83
19.48
7.5
6.8
3.5
8.0
14.06
10.99
0.78
1.79
19.66
7.8
PSI
FT
3.4
0.3
0.8
5.1
0.5
1.1
6.8
0.7
1.5
Operation not recommended
Interpolation is permissible; extrapolation is not.
All entering air conditions are 80В°F DB and 67В°F WB in cooling, and 70В°F DB in heating.
AHRI/ISO certified conditions are 80.6В°F DB and 66.2В°F WB in cooling and 68В°F DB in heating.
Table does not reflect fan or pump power corrections for AHRI/ISO conditions.
All performance is based upon the lower voltage of dual voltage rated units.
Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated.
Operation below 40В°F EWT is based upon a 15% methanol antifreeze solution.
Operation below 60В°F EWT requires optional insulated water/refrigerant circuit.
See performance correction tables for operating conditions other than those listed above.
See Performance Data Selection Notes for operation in the shaded areas.
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 18
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Performance Data – TSL24 with PSC Motor
850 CFM Nominal (Rated) Airflow
*WPD Adder for
Motorized Valve,
TSL24
(Cv = 10.3,
MOPD = 150 psi)
GPM
WPD Adder
PSI
FT
4.0
0.4
0.9
6.0
0.6
1.3
8.0
0.8
1.8
Performance capacities shown in thousands of Btuh
WPD*
EWT
В°F
20
30
40
50
60
70
80
90
100
110
120
Cooling - EAT 80/67В°F
GPM
PSI
FT
TC
SC
Sens/Tot
Ratio
Heating - EAT 70В°F
kW
HR
EER
HC
kW
HE
LAT
COP
17.55
1.73
12.11
87.1
3.0
4.0
0.8
6.0
2.5
8.0
5.2
12.1
4.0
0.9
2.1
33.57
21.59
0.64
1.06
36.72
31.8
19.10
1.72
13.69
88.8
3.3
6.0
2.3
5.3
34.11
21.76
0.64
0.99
37.03
34.4
19.80
1.72
14.39
89.5
3.4
8.0
5.0
11.4
34.31
21.80
0.64
0.96
37.13
35.7
20.20
1.72
14.79
90.0
3.4
4.0
0.7
1.6
32.53
21.15
0.65
1.16
36.03
28.0
21.81
1.73
16.37
91.7
3.7
6.0
2.3
5.2
33.29
21.48
0.65
1.09
36.54
30.6
22.77
1.74
17.30
92.8
3.8
8.0
4.6
10.7
33.62
21.61
0.64
1.05
36.75
32.0
23.31
1.74
17.82
93.3
3.9
4.0
0.5
1.1
31.23
20.51
0.66
1.28
35.13
24.4
24.83
1.76
19.27
95.0
4.1
6.0
2.2
5.1
32.14
20.97
0.65
1.20
35.76
26.9
26.06
1.78
20.44
96.3
4.3
8.0
4.3
9.9
32.57
21.17
0.65
1.16
36.05
28.2
26.75
1.79
21.10
97.1
4.4
4.0
0.4
1.0
29.72
19.72
0.66
1.42
34.11
20.9
28.05
1.82
22.32
98.5
4.5
6.0
2.0
4.6
30.74
20.26
0.66
1.33
34.80
23.2
29.55
1.84
23.72
100.1
4.7
8.0
4.0
9.3
31.23
20.51
0.66
1.28
35.14
24.4
30.38
1.86
24.49
101.0
4.8
4.0
0.4
0.9
28.06
18.82
0.67
1.59
33.02
17.7
31.39
1.88
25.43
102.1
4.9
6.0
1.8
4.1
29.14
19.41
0.67
1.48
33.72
19.7
33.13
1.92
27.03
104.0
5.1
8.0
3.8
8.7
29.67
19.70
0.66
1.43
34.08
20.8
34.08
1.94
27.91
105.0
5.1
4.0
0.3
0.7
26.31
17.83
0.68
1.78
31.93
14.7
34.76
1.96
28.53
105.8
5.2
6.0
1.7
4.0
27.40
18.45
0.67
1.66
32.60
16.5
36.67
2.01
30.28
107.9
5.4
8.0
3.5
8.1
27.96
18.76
0.67
1.60
32.95
17.5
37.70
2.03
31.23
109.0
5.4
4.0
0.3
0.7
24.51
16.80
0.69
2.01
30.92
12.2
38.05
2.04
31.54
109.4
5.5
6.0
1.8
4.2
25.59
17.43
0.68
1.87
31.52
13.7
40.07
2.10
33.38
111.5
5.6
41.13
2.12
34.34
112.7
5.7
Operation not recommended
8.0
3.2
7.4
26.15
17.74
0.68
1.80
31.84
14.5
4.0
0.3
0.6
22.72
15.77
0.69
2.28
30.05
9.9
6.0
1.6
3.7
23.76
16.37
0.69
2.12
30.54
11.2
8.0
3.0
6.9
24.30
16.68
0.69
2.04
30.81
11.9
4.0
0.2
0.5
21.00
14.77
0.70
2.60
29.41
8.1
6.0
1.6
3.7
21.96
15.33
0.70
2.42
29.74
9.1
8.0
2.9
6.7
22.47
15.62
0.70
2.33
29.95
9.7
4.0
0.2
0.4
19.39
13.84
0.71
2.97
29.07
6.5
6.0
1.0
2.3
20.26
14.34
0.71
2.76
29.21
7.3
8.0
2.8
6.6
20.73
14.61
0.70
2.66
29.33
7.8
Operation not recommended
Interpolation is permissible; extrapolation is not.
All entering air conditions are 80В°F DB and 67В°F WB in cooling, and 70В°F DB in heating.
AHRI/ISO certified conditions are 80.6В°F DB and 66.2В°F WB in cooling and 68В°F DB in heating.
Table does not reflect fan or pump power corrections for AHRI/ISO conditions.
All performance is based upon the lower voltage of dual voltage rated units.
Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated.
Operation below 40В°F EWT is based upon a 15% methanol antifreeze solution.
Operation below 60В°F EWT requires optional insulated water/refrigerant circuit.
See performance correction tables for operating conditions other than those listed above.
See Performance Data Selection Notes for operation in the shaded areas.
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 19
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Performance Data – TSL30 with PSC Motor
1000 CFM Nominal (Rated) Airflow
Performance capacities shown in thousands of Btuh
WPD*
EWT
В°F
20
30
40
50
60
70
80
90
100
110
120
Cooling - EAT 80/67В°F
GPM
PSI
FT
TC
SC
Sens/Tot
Ratio
kW
Heating - EAT 70В°F
HR
4.0
1.2
6.0
2.5
8.0
5.2
12.1
4.0
0.9
2.1
33.05
22.48
0.68
1.30
36.75
6.0
2.3
5.3
32.29
21.97
0.68
1.23
35.77
8.0
5.0
11.4
31.79
21.64
0.68
1.20
4.0
0.7
1.6
33.55
22.84
0.68
6.0
2.3
5.2
33.34
22.68
8.0
4.6
10.7
33.12
22.53
4.0
0.5
1.1
33.29
6.0
2.2
5.1
33.53
8.0
4.3
9.9
4.0
0.4
6.0
2.0
8.0
4.0
EER
HC
kW
HE
LAT
COP
Operation not recommended
*WPD Adder for
Motorized Valve,
TSL30
(Cv = 10.3,
MOPD = 150 psi)
GPM
17.82
1.93
11.96
84.5
2.7
25.4
20.35
1.97
14.35
86.8
3.0
26.2
21.25
1.99
15.20
87.6
3.1
35.17
26.4
21.74
2.00
15.67
88.1
3.2
1.42
37.65
23.7
23.88
2.03
17.69
90.1
3.4
0.68
1.34
37.19
24.8
24.96
2.05
18.71
91.1
3.6
0.68
1.31
36.85
25.3
25.54
2.06
19.25
91.6
3.6
22.75
0.68
1.55
37.84
21.5
27.28
2.08
20.90
93.2
3.8
22.85
0.68
1.46
37.79
22.9
28.49
2.10
22.05
94.3
4.0
33.56
22.85
0.68
1.42
37.68
23.6
29.14
2.12
22.65
94.9
4.0
1.0
32.45
22.34
0.69
1.70
37.51
19.1
30.51
2.14
23.95
96.2
4.2
4.6
33.04
22.63
0.68
1.60
37.76
20.7
31.79
2.16
25.16
97.4
4.3
4.0
9.3
33.26
22.74
0.68
1.55
37.83
21.4
32.47
2.17
25.79
98.0
4.4
0.4
0.9
31.16
21.69
0.70
1.87
36.81
16.7
33.50
2.19
26.76
98.9
4.5
6.0
1.8
4.1
32.01
22.11
0.69
1.76
37.28
18.2
34.79
2.21
27.97
100.1
4.6
8.0
3.8
8.7
32.38
22.30
0.69
1.71
37.47
19.0
35.45
2.23
28.59
100.7
4.7
4.0
0.3
0.7
29.53
20.87
0.71
2.07
35.88
14.2
36.18
2.24
29.28
101.4
4.7
6.0
1.7
4.0
30.56
21.38
0.70
1.95
36.47
15.7
37.40
2.26
30.42
102.5
4.8
8.0
3.5
8.1
31.04
21.63
0.70
1.89
36.74
16.5
38.00
2.27
30.97
103.1
4.9
4.0
0.3
0.7
27.66
19.95
0.72
2.31
34.83
12.0
38.48
2.28
31.42
103.5
4.9
6.0
1.8
4.2
28.79
20.50
0.71
2.17
35.46
13.3
39.53
2.31
32.40
104.5
5.0
8.0
3.2
7.4
29.35
20.78
0.71
2.10
35.77
14.0
40.02
2.32
32.85
105.0
5.1
4.0
0.3
0.6
25.63
18.96
0.74
2.60
33.76
9.9
6.0
1.6
3.7
26.81
19.53
0.73
2.43
34.37
11.0
8.0
3.0
6.9
27.40
19.82
0.72
2.35
34.68
11.7
4.0
0.2
0.5
23.53
17.95
0.76
2.93
32.79
8.0
6.0
1.6
3.7
24.70
18.51
0.75
2.74
33.31
9.0
8.0
2.9
6.7
25.30
18.80
0.74
2.65
33.60
9.6
4.0
0.2
0.4
21.44
16.97
0.79
3.32
32.03
6.5
6.0
1.0
2.3
22.56
17.49
0.78
3.10
32.41
7.3
8.0
2.8
6.6
23.14
17.77
0.77
3.00
32.63
7.7
WPD Adder
PSI
FT
4.0
0.4
0.9
6.0
0.6
1.3
8.0
0.8
1.8
Operation not recommended
Interpolation is permissible; extrapolation is not.
All entering air conditions are 80В°F DB and 67В°F WB in cooling, and 70В°F DB in heating.
AHRI/ISO certified conditions are 80.6В°F DB and 66.2В°F WB in cooling and 68В°F DB in heating.
Table does not reflect fan or pump power corrections for AHRI/ISO conditions.
All performance is based upon the lower voltage of dual voltage rated units.
Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated.
Operation below 40В°F EWT is based upon a 15% methanol antifreeze solution.
Operation below 60В°F EWT requires optional insulated water/refrigerant circuit.
See performance correction tables for operating conditions other than those listed above.
See Performance Data Selection Notes for operation in the shaded areas.
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 20
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Performance Data – TSL36 with PSC Motor
1200 CFM Nominal (Rated) Airflow
*WPD Adder for
Motorized Valve,
TSL36
(Cv = 10.3,
MOPD = 150 psi)
GPM
EWT
В°F
WPD Adder
PSI
FT
4.5
0.4
1.0
6.8
0.7
1.5
9.0
0.9
2.0
Performance capacities shown in thousands of Btuh
WPD*
20
30
40
50
60
70
80
90
100
110
120
Cooling - EAT 80/67В°F
GPM
PSI
4.5
3.7
6.0
5.0
FT
TC
SC
Sens/Tot
Ratio
kW
Heating - EAT 70В°F
HR
EER
HC
kW
HE
LAT
COP
Operation not recommended
9.0
8.6
19.8
23.28
2.31
15.72
85.9
3.0
4.5
2.8
6.4
46.36
30.52
0.66
1.62
52.07
29.0
26.08
2.35
18.36
88.1
3.2
6.0
3.8
8.8
46.90
30.81
0.66
1.51
52.26
31.3
27.35
2.37
19.56
89.1
3.4
9.0
7.4
17.0
47.08
30.90
0.66
1.47
52.27
32.5
28.06
2.38
20.23
89.6
3.4
4.5
1.8
4.3
45.35
29.95
0.66
1.77
51.56
26.0
30.51
2.42
22.56
91.5
3.7
6.0
2.6
5.9
46.16
30.41
0.66
1.65
51.98
28.3
32.12
2.45
24.08
92.7
3.8
9.0
7.0
16.3
46.49
30.59
0.66
1.60
52.12
29.4
33.01
2.46
24.92
93.4
3.9
4.5
0.9
2.1
44.01
29.22
0.66
1.94
50.82
22.9
35.03
2.49
26.83
95.0
4.1
6.0
2.4
5.6
45.06
29.79
0.66
1.80
51.40
25.3
36.94
2.52
28.65
96.4
4.3
9.0
4.7
10.7
45.52
30.05
0.66
1.74
51.65
26.4
38.00
2.54
29.65
97.3
4.4
4.5
0.9
2.0
42.36
28.34
0.67
2.15
49.89
19.9
39.53
2.56
31.09
98.4
4.5
6.0
2.3
5.3
43.62
29.01
0.67
1.99
50.60
22.2
41.72
2.60
33.15
100.1
4.7
9.0
4.4
10.3
44.20
29.32
0.66
1.91
50.93
23.3
42.91
2.62
34.28
101.0
4.8
4.5
0.8
1.8
40.44
27.36
0.68
2.40
48.83
17.0
43.95
2.64
35.25
101.8
4.9
6.0
2.2
5.1
41.88
28.09
0.67
2.21
49.62
19.2
46.34
2.69
37.48
103.7
5.1
9.0
4.3
10.0
42.56
28.45
0.67
2.12
50.00
20.3
47.62
2.71
38.67
104.7
5.1
4.5
0.8
1.8
38.26
26.28
0.69
2.71
47.70
14.3
48.21
2.73
39.21
105.1
5.2
6.0
2.1
4.9
39.85
27.06
0.68
2.48
48.52
16.3
50.69
2.78
41.50
107.0
5.3
9.0
4.2
9.6
40.62
27.45
0.68
2.38
48.93
17.3
52.00
2.82
42.69
108.0
5.4
4.5
0.8
1.8
35.85
25.12
0.70
3.08
46.54
11.8
52.19
2.82
42.87
108.2
5.4
6.0
2.1
4.9
37.57
25.94
0.69
2.81
47.35
13.5
54.65
2.90
45.08
110.1
5.5
9.0
4.0
9.3
38.41
26.35
0.69
2.69
47.77
14.5
55.89
2.94
46.17
111.0
5.6
4.5
0.7
1.7
33.20
23.86
0.72
3.52
45.40
9.6
6.0
2.1
4.8
35.03
24.73
0.71
3.21
46.17
11.1
9.0
3.9
9.1
35.93
25.16
0.70
3.06
46.58
11.9
4.5
0.7
1.5
30.35
22.50
0.74
4.04
44.33
7.6
6.0
2.0
4.6
32.28
23.42
0.73
3.68
45.03
8.9
9.0
3.9
8.9
33.23
23.87
0.72
3.51
45.41
9.6
4.5
0.6
1.5
27.29
21.02
0.77
4.66
43.37
6.0
6.0
1.9
4.4
29.31
22.00
0.75
4.24
43.98
7.0
9.0
3.6
8.4
30.30
22.48
0.74
4.05
44.31
7.6
Operation not recommended
Interpolation is permissible; extrapolation is not.
All entering air conditions are 80В°F DB and 67В°F WB in cooling, and 70В°F DB in heating.
AHRI/ISO certified conditions are 80.6В°F DB and 66.2В°F WB in cooling and 68В°F DB in heating.
Table does not reflect fan or pump power corrections for AHRI/ISO conditions.
All performance is based upon the lower voltage of dual voltage rated units.
Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated.
Operation below 40В°F EWT is based upon a 15% methanol antifreeze solution.
Operation below 60В°F EWT requires optional insulated water/refrigerant circuit.
See performance correction tables for operating conditions other than those listed above.
See Performance Data Selection Notes for operation in the shaded areas.
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 21
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Performance Data – TSL09 with ECM Motor
400 CFM Nominal Airflow Heating, 350 CFM Nominal Airflow Cooling
WPD
EWT
В°F
20
30
40
50
60
70
80
90
100
110
120
GPM
PSI
FT
Performance capacities shown in thousands of Btuh
Cooling - EAT 80/67В°F
TC
SC
Sens/Tot
Ratio
Heating - EAT 70В°F
kW
HR
EER
HC
kW
HE
LAT
COP
6.18
0.65
3.96
75.6
2.8
1.5
1.6
2.3
1.8
3.0
5.7
13.2
1.5
1.1
2.6
13.23
9.05
0.68
0.41
14.61
32.5
7.21
0.66
4.95
76.9
3.2
2.3
1.8
4.0
13.10
8.80
0.67
0.39
14.43
33.4
7.55
0.67
5.28
77.3
3.3
3.0
4.7
10.7
12.97
8.63
0.67
0.39
14.29
33.5
7.74
0.67
5.46
77.5
1.5
0.8
1.9
13.12
9.21
0.70
0.44
14.64
29.6
8.69
0.68
6.39
78.7
2.3
1.7
3.9
13.23
9.14
0.69
0.42
14.65
31.6
9.16
0.68
6.84
79.3
3.9
3.0
4.1
9.6
13.23
9.06
0.69
0.41
14.62
32.4
9.42
0.68
7.09
79.6
4.0
1.5
0.5
1.1
12.74
9.16
0.72
0.49
14.42
25.9
10.24
0.69
7.89
80.6
4.4
2.3
1.6
3.7
13.02
9.21
0.71
0.46
14.58
28.3
10.83
0.69
8.47
81.3
4.6
3.0
3.6
8.4
13.12
9.21
0.70
0.44
14.63
29.5
11.16
0.69
8.79
81.7
4.7
1.5
0.4
1.0
12.15
8.95
0.74
0.55
14.03
22.1
11.80
0.70
9.42
82.5
5.0
2.3
1.5
3.5
12.55
9.09
0.72
0.51
14.29
24.5
12.50
0.70
10.11
83.4
5.2
3.0
4.0
9.3
12.72
9.15
0.72
0.49
14.41
25.8
12.89
0.70
10.49
83.9
5.4
1.5
0.4
0.9
11.43
8.64
0.76
0.61
13.52
18.6
13.35
0.71
10.94
84.4
5.5
2.3
1.4
3.3
11.89
8.84
0.74
0.57
13.84
20.7
14.13
0.71
11.71
85.4
5.8
3.0
3.0
7.0
12.11
8.93
0.74
0.55
14.00
21.9
14.56
0.71
12.13
85.9
6.0
1.5
0.3
0.8
10.61
8.27
0.78
0.68
12.94
15.6
14.83
0.71
12.40
86.3
6.1
2.3
1.3
3.1
11.10
8.49
0.76
0.64
13.29
17.3
15.66
0.72
13.22
87.3
6.4
3.0
3.1
7.1
11.35
8.60
0.76
0.62
13.46
18.3
16.09
0.72
13.65
87.8
6.6
1.5
0.3
0.7
9.76
7.87
0.81
0.75
12.33
12.9
16.21
0.72
13.76
88.0
6.6
2.3
1.5
3.5
10.24
8.10
0.79
0.71
12.68
14.4
17.03
0.72
14.57
89.0
6.9
3.0
3.1
7.2
10.49
8.21
0.78
0.69
12.86
15.2
17.43
0.72
14.98
89.5
7.1
1.5
0.1
0.2
8.91
7.49
0.84
0.83
11.73
10.8
2.3
1.2
2.9
9.36
7.69
0.82
0.79
12.05
11.9
3.0
2.8
6.4
9.60
7.80
0.81
0.77
12.22
12.5
1.5
0.1
0.2
8.11
7.16
0.88
0.90
11.18
9.0
2.3
1.2
2.8
8.51
7.32
0.86
0.86
11.45
9.9
3.0
2.7
6.2
8.72
7.41
0.85
0.84
11.60
10.3
1.5
0.1
0.2
7.41
6.93
0.93
0.97
10.72
7.6
2.3
1.2
2.7
7.74
7.03
0.91
0.94
10.93
8.3
3.0
2.6
6.0
7.92
7.09
0.90
0.92
11.05
8.6
*WPD Adder for
Motorized Valve,
TSL09
(Cv = 4.9,
MOPD = 150 psi)
Operation not recommended
WPD Adder
GPM
PSI
FT
1.5
0.3
0.7
3.4
2.3
0.5
1.1
3.8
3.0
0.6
1.4
Operation not recommended
Interpolation is permissible; extrapolation is not.
All entering air conditions are 80В°F DB and 67В°F WB in cooling, and 70В°F DB in heating.
AHRI/ISO certified conditions are 80.6В°F DB and 66.2В°F WB in cooling and 68В°F DB in heating.
Table does not reflect fan or pump power corrections for AHRI/ISO conditions.
All performance is based upon the lower voltage of dual voltage rated units.
Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated.
Operation below 40В°F EWT is based upon a 15% methanol antifreeze solution.
Operation below 60В°F EWT requires optional insulated water/refrigerant circuit.
See performance correction tables for operating conditions other than those listed above.
See Performance Data Selection Notes for operation in the shaded areas.
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 22
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Performance Data – TSL12 with ECM Motor
500 CFM Nominal Airflow Heating, 400 CFM Nominal Airflow Cooling
*WPD Adder for
Motorized Valve,
TSL12
(Cv = 4.9,
MOPD = 150 psi)
WPD Adder
WPD
EWT
В°F
20
GPM
PSI
FT
1.8
0.4
0.8
2.6
0.5
1.2
3.5
0.7
1.7
30
40
50
60
70
80
90
100
110
120
GPM
PSI
Performance capacities shown in thousands of Btuh
Cooling - EAT 80/67В°F
FT
TC
SC
Sens/Tot
Ratio
kW
Heating - EAT 70В°F
HR
EER
HC
kW
HE
LAT
COP
1.8
4.1
2.7
6.3
3.5
9.4
21.7
7.76
0.77
5.13
83.9
2.9
1.8
3.4
7.9
15.67
10.25
0.65
0.41
17.07
38.2
8.92
0.79
6.23
86.3
3.3
2.7
5.6
13.0
15.78
10.15
0.64
0.37
17.05
42.4
9.25
0.79
6.54
87.0
3.4
3.5
7.8
18.0
15.79
10.06
0.64
0.35
17.00
44.5
9.43
0.80
6.71
87.4
3.5
1.8
2.9
6.6
15.30
10.23
0.67
0.47
16.92
32.2
10.50
0.81
7.72
89.6
3.8
2.7
4.9
11.4
15.56
10.27
0.66
0.43
17.04
36.0
10.92
0.82
8.12
90.4
3.9
3.5
6.2
14.4
15.66
10.25
0.65
0.41
17.07
38.0
11.16
0.83
8.34
90.9
4.0
1.8
2.3
5.3
14.74
10.05
0.68
0.54
16.60
27.1
12.11
0.84
9.24
92.9
4.2
2.7
4.2
9.8
15.12
10.18
0.67
0.50
16.82
30.3
12.62
0.85
9.71
93.9
4.3
3.5
7.7
17.8
15.28
10.23
0.67
0.48
16.91
32.1
12.90
0.86
9.97
94.5
4.4
1.8
2.3
5.3
14.04
9.75
0.69
0.62
16.16
22.7
13.72
0.87
10.74
96.2
4.6
2.7
4.1
9.5
14.49
9.95
0.69
0.57
16.45
25.3
14.30
0.89
11.28
97.4
4.7
3.5
5.9
13.6
14.71
10.04
0.68
0.55
16.58
26.8
14.62
0.89
11.57
98.0
4.8
1.8
2.2
5.2
13.23
9.37
0.71
0.70
15.62
18.9
15.30
0.91
12.21
99.4
4.9
2.7
4.0
9.1
13.73
9.60
0.70
0.65
15.95
21.1
15.93
0.92
12.79
100.7
5.1
3.5
6.2
14.3
13.98
9.72
0.70
0.63
16.12
22.3
16.27
0.93
13.11
101.4
5.2
1.8
2.1
4.9
12.35
8.94
0.72
0.78
15.02
15.8
16.81
0.94
13.61
102.5
5.3
2.7
3.9
8.9
12.87
9.19
0.71
0.73
15.38
17.5
17.47
0.95
14.23
103.9
5.4
3.5
5.6
13.0
13.14
9.32
0.71
0.71
15.56
18.5
17.82
0.96
14.56
104.6
5.5
1.8
2.1
4.8
11.43
8.49
0.74
0.87
14.40
13.1
18.22
0.96
14.93
105.4
5.5
2.7
3.7
8.7
11.95
8.74
0.73
0.82
14.75
14.5
18.88
0.98
15.55
106.8
5.7
3.5
5.5
12.7
12.22
8.87
0.73
0.80
14.93
15.3
19.22
0.98
15.87
107.5
5.7
10.9
Operation not recommended
1.8
1.9
4.4
10.50
8.05
0.77
0.96
13.78
2.7
3.4
7.8
11.00
8.29
0.75
0.91
14.11
12.1
3.5
5.4
12.4
11.26
8.41
0.75
0.89
14.29
12.7
1.8
1.8
4.2
9.59
7.65
0.80
1.05
13.19
9.1
2.7
3.3
7.7
10.05
7.85
0.78
1.01
13.49
10.0
3.5
5.3
12.2
10.30
7.96
0.77
0.98
13.65
10.5
1.8
1.8
4.1
8.74
7.29
0.83
1.15
12.66
7.6
2.7
3.3
7.5
9.15
7.46
0.82
1.10
12.91
8.3
3.5
5.2
11.9
9.37
7.55
0.81
1.08
13.05
8.7
Operation not recommended
Interpolation is permissible; extrapolation is not.
All entering air conditions are 80В°F DB and 67В°F WB in cooling, and 70В°F DB in heating.
AHRI/ISO certified conditions are 80.6В°F DB and 66.2В°F WB in cooling and 68В°F DB in heating.
Table does not reflect fan or pump power corrections for AHRI/ISO conditions.
All performance is based upon the lower voltage of dual voltage rated units.
Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated.
Operation below 40В°F EWT is based upon a 15% methanol antifreeze solution.
Operation below 60В°F EWT requires optional insulated water/refrigerant circuit.
See performance correction tables for operating conditions other than those listed above.
See Performance Data Selection Notes for operation in the shaded areas.
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 23
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Performance Data – TSL15 with ECM Motor
600 CFM Nominal (Rated) Airflow
Performance capacities shown in thousands of Btuh
WPD
EWT
В°F
20
30
40
50
60
70
80
90
100
110
120
Cooling - EAT 80/67В°F
GPM
PSI
FT
TC
SC
Sens/Tot
Ratio
kW
Heating - EAT 70В°F
HR
EER
HC
kW
HE
LAT
COP
8.69
0.83
6.15
81.8
3.2
2.3
2.4
3.5
5.8
4.5
8.8
20.3
2.3
2.3
5.4
17.43
11.10
0.64
0.50
19.15
34.5
10.14
0.86
7.51
84.1
3.6
3.5
5.0
11.6
16.92
10.50
0.62
0.48
18.56
35.4
10.61
0.87
7.95
84.8
3.7
4.5
8.3
19.2
16.60
10.17
0.61
0.47
18.20
35.5
10.86
0.87
8.19
85.2
3.8
2.3
2.2
3.5
4.5
*WPD Adder for
Motorized Valve,
TSL15
(Cv = 10.3,
MOPD = 150 psi)
Operation not recommended
WPD Adder
5.1
17.82
11.84
0.66
0.57
19.75
31.5
12.11
0.89
9.37
87.1
4.1
4.3
9.8
17.67
11.46
0.65
0.53
19.47
33.4
12.68
0.90
9.91
88.0
4.2
7.7
17.8
17.52
11.23
0.64
0.51
19.27
34.2
12.99
0.90
10.21
88.5
4.3
2.3
2.1
4.8
17.69
12.22
0.69
0.64
19.87
27.7
14.04
0.92
11.20
90.1
4.6
3.5
4.2
9.7
17.82
12.04
0.68
0.59
19.85
30.0
14.71
0.93
11.84
91.1
4.7
4.5
7.1
16.4
17.83
11.91
0.67
0.57
19.79
31.1
15.08
0.94
12.18
91.7
4.8
2.3
2.1
4.9
17.17
12.30
0.72
0.73
19.64
23.7
15.94
0.95
13.01
93.0
5.0
3.5
4.2
9.7
17.52
12.29
0.70
0.67
19.81
26.0
16.70
0.96
13.73
94.2
5.2
4.5
7.0
16.1
17.65
12.24
0.69
0.65
19.86
27.2
17.11
0.96
14.12
94.8
5.3
2.3
2.0
4.7
16.36
12.13
0.74
0.82
19.16
20.0
17.79
0.97
14.78
95.9
5.5
3.5
4.2
9.6
16.85
12.26
0.73
0.76
19.46
22.1
18.63
0.98
15.58
97.1
5.7
4.5
6.9
15.8
17.08
12.29
0.72
0.74
19.59
23.2
19.08
0.99
16.01
97.8
5.8
2.3
2.0
4.5
15.34
11.77
0.77
0.92
18.49
16.6
19.59
0.99
16.51
98.6
5.9
3.5
4.0
9.2
15.93
11.99
0.75
0.86
18.88
18.4
20.50
1.00
17.39
100.0
6.1
4.5
6.6
15.3
16.21
12.09
0.75
0.83
19.06
19.4
20.98
1.00
17.85
100.8
6.2
2.3
1.9
4.4
14.19
11.25
0.79
1.03
17.71
13.8
21.33
1.01
18.20
101.3
6.3
3.5
3.9
9.0
14.82
11.55
0.78
0.97
18.14
15.3
22.29
1.01
19.14
102.8
6.5
4.5
6.6
15.3
15.14
11.68
0.77
0.94
18.35
16.1
22.80
1.01
19.64
103.6
6.7
2.3
1.9
4.4
12.97
10.63
0.82
1.15
16.89
11.3
3.5
3.9
8.9
13.61
10.96
0.81
1.09
17.31
12.5
4.5
6.5
15.0
13.93
11.12
0.80
1.06
17.53
13.2
2.3
1.9
4.4
11.74
9.95
0.85
1.27
16.06
9.3
3.5
3.9
8.9
12.34
10.28
0.83
1.21
16.46
10.2
4.5
6.4
14.8
12.65
10.46
0.83
1.18
16.67
10.8
2.3
1.9
4.4
10.56
9.25
0.88
1.39
15.30
7.6
3.5
3.8
8.8
11.10
9.57
0.86
1.33
15.64
8.3
4.5
6.3
14.6
11.38
9.74
0.86
1.30
15.83
8.7
GPM
PSI
FT
2.3
0.2
0.5
3.5
0.3
0.8
4.5
0.4
1.1
Operation not recommended
Interpolation is permissible; extrapolation is not.
All entering air conditions are 80В°F DB and 67В°F WB in cooling, and 70В°F DB in heating.
AHRI/ISO certified conditions are 80.6В°F DB and 66.2В°F WB in cooling and 68В°F DB in heating.
Table does not reflect fan or pump power corrections for AHRI/ISO conditions.
All performance is based upon the lower voltage of dual voltage rated units.
Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated.
Operation below 40В°F EWT is based upon a 15% methanol antifreeze solution.
Operation below 60В°F EWT requires optional insulated water/refrigerant circuit.
See performance correction tables for operating conditions other than those listed above.
See Performance Data Selection Notes for operation in the shaded areas.
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 24
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Performance Data – TSL18 with ECM Motor
700 CFM Nominal (Rated) Airflow
*WPD Adder for
Motorized Valve,
TSL18
(Cv = 10.3,
MOPD = 150 psi)
WPD Adder
EWT
В°F
20
GPM
PSI
FT
3.4
0.3
0.8
5.1
0.5
1.1
6.8
0.7
1.5
Performance capacities shown in thousands of Btuh
WPD
30
40
50
60
70
80
90
100
110
120
Cooling - EAT 80/67В°F
GPM
PSI
FT
TC
SC
Sens/Tot
Ratio
kW
Heating - EAT 70В°F
HR
EER
HC
kW
HE
LAT
COP
10.67
1.03
7.16
82.1
3.0
38.5
12.64
1.06
9.01
84.7
3.5
3.4
5.1
2.6
4.7
6.8
7.2
16.7
3.4
2.2
5.1
5.1
4.2
9.7
23.88
15.52
0.65
0.58
25.85
41.4
13.10
1.07
9.45
85.3
3.6
6.8
6.7
15.4
23.89
15.38
0.64
0.56
25.79
42.8
13.36
1.08
9.69
85.6
3.6
3.4
1.9
4.3
23.35
15.80
0.68
0.70
25.75
33.2
15.18
1.11
11.41
88.0
4.0
5.1
3.8
8.7
23.61
15.81
0.67
0.66
25.86
35.8
15.79
1.12
11.98
88.8
4.1
6.8
5.4
12.5
23.71
15.77
0.67
0.64
25.89
37.2
16.12
1.12
12.29
89.3
4.2
3.4
1.5
3.5
22.61
15.55
0.69
0.80
25.33
28.3
17.78
1.15
13.87
91.5
4.5
5.1
3.3
7.7
23.01
15.71
0.68
0.75
25.57
30.7
18.53
1.16
14.57
92.5
4.7
6.8
4.4
10.0
23.19
15.76
0.68
0.73
25.67
31.9
18.93
1.16
14.96
93.0
4.8
3.4
1.5
3.3
21.63
15.06
0.70
0.90
24.70
24.0
20.40
1.19
16.36
94.9
5.0
5.1
2.9
6.6
22.13
15.32
0.69
0.85
25.03
26.0
21.29
1.20
17.20
96.1
5.2
6.8
4.3
9.9
22.37
15.44
0.69
0.82
25.19
27.1
21.77
1.21
17.66
96.7
5.3
3.4
1.4
3.2
20.45
14.40
0.70
1.01
23.91
20.2
23.04
1.22
18.87
98.4
5.5
5.1
2.4
5.5
21.03
14.73
0.70
0.96
24.30
21.9
24.07
1.24
19.85
99.8
5.7
6.8
4.2
9.6
21.31
14.89
0.70
0.93
24.49
22.9
24.62
1.24
20.38
100.5
5.8
3.4
1.1
2.4
19.13
13.65
0.71
1.14
23.01
16.8
25.68
1.26
21.38
101.9
6.0
5.1
2.6
6.0
19.75
14.01
0.71
1.08
23.43
18.3
26.83
1.27
22.49
103.4
6.2
6.8
4.1
9.5
20.06
14.18
0.71
1.05
23.65
19.1
27.45
1.28
23.08
104.2
6.3
3.4
1.1
2.5
17.71
12.86
0.73
1.27
22.04
13.9
28.29
1.29
23.89
105.3
6.4
5.1
2.8
6.6
18.35
13.21
0.72
1.21
22.47
15.2
29.56
1.30
25.11
107.0
6.6
6.8
4.0
9.3
18.67
13.39
0.72
1.18
22.69
15.8
30.24
1.31
25.76
107.9
6.8
3.4
1.1
2.5
16.22
12.07
0.74
1.41
21.04
11.5
5.1
2.2
5.0
16.85
12.40
0.74
1.35
21.46
12.5
6.8
3.6
8.4
17.17
12.57
0.73
1.32
21.68
13.0
3.4
1.0
2.2
14.70
11.30
0.77
1.57
20.06
9.3
5.1
2.1
4.9
15.31
11.60
0.76
1.51
20.45
10.2
6.8
3.5
8.2
15.62
11.76
0.75
1.47
20.65
10.6
3.4
1.0
2.2
13.19
10.58
0.80
1.74
19.13
7.6
5.1
2.1
4.7
13.76
10.85
0.79
1.68
19.48
8.2
6.8
3.5
8.0
14.06
10.99
0.78
1.64
19.66
8.6
Operation not recommended
23.79
15.72
0.66
0.62
25.90
Operation not recommended
Interpolation is permissible; extrapolation is not.
All entering air conditions are 80В°F DB and 67В°F WB in cooling, and 70В°F DB in heating.
AHRI/ISO certified conditions are 80.6В°F DB and 66.2В°F WB in cooling and 68В°F DB in heating.
Table does not reflect fan or pump power corrections for AHRI/ISO conditions.
All performance is based upon the lower voltage of dual voltage rated units.
Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated.
Operation below 40В°F EWT is based upon a 15% methanol antifreeze solution.
Operation below 60В°F EWT requires optional insulated water/refrigerant circuit.
See performance correction tables for operating conditions other than those listed above.
See Performance Data Selection Notes for operation in the shaded areas.
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 25
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Performance Data – TSL24 with ECM Motor
850 CFM Nominal (Rated) Airflow
Performance capacities shown in thousands of Btuh
WPD
EWT
В°F
20
30
40
50
60
70
80
90
100
110
120
Cooling - EAT 80/67В°F
GPM
PSI
FT
TC
SC
4.0
6.0
3.9
2.5
8.0
5.2
12.1
4.0
0.9
2.1
6.0
2.3
5.3
34.11
21.76
8.0
5.0
11.4
34.31
21.80
4.0
0.7
6.0
8.0
Sens/Tot
Ratio
kW
Heating - EAT 70В°F
HR
EER
HC
kW
HE
LAT
COP
17.55
1.60
12.11
87.1
3.2
*WPD Adder for
Motorized Valve,
TSL24
(Cv = 10.3,
MOPD = 150 psi)
Operation not recommended
33.57
21.59
0.64
0.92
36.72
36.4
19.10
1.59
13.69
88.8
3.5
0.64
0.86
37.03
39.8
19.80
1.59
14.39
89.5
3.7
0.64
0.83
37.13
41.6
20.20
1.59
14.79
90.0
3.7
1.6
32.53
21.15
0.65
1.03
36.03
31.7
21.81
1.59
16.37
91.7
4.0
2.3
5.2
33.29
21.48
0.65
0.95
36.54
35.0
22.77
1.60
17.30
92.8
4.2
4.6
10.7
33.62
21.61
0.64
0.92
36.75
36.7
23.31
1.61
17.82
93.3
4.2
4.0
0.5
1.1
31.23
20.51
0.66
1.15
35.13
27.3
24.83
1.63
19.27
95.0
4.5
6.0
2.2
5.1
32.14
20.97
0.65
1.06
35.76
30.3
26.06
1.65
20.44
96.3
4.6
8.0
4.3
9.9
32.57
21.17
0.65
1.02
36.05
31.9
26.75
1.66
21.10
97.1
4.7
4.0
0.4
1.0
29.72
19.72
0.66
1.29
34.11
23.1
28.05
1.68
22.32
98.5
4.9
6.0
2.0
4.6
30.74
20.26
0.66
1.19
34.80
25.8
29.55
1.71
23.72
100.1
5.1
8.0
4.0
9.3
31.23
20.51
0.66
1.15
35.14
27.3
30.38
1.73
24.49
101.0
5.2
4.0
0.4
0.9
28.06
18.82
0.67
1.45
33.02
19.3
31.39
1.75
25.43
102.1
5.3
6.0
1.8
4.1
29.14
19.41
0.67
1.34
33.72
21.7
33.13
1.79
27.03
104.0
5.4
8.0
3.8
8.7
29.67
19.70
0.66
1.29
34.08
23.0
34.08
1.81
27.91
105.0
5.5
4.0
0.3
0.7
26.31
17.83
0.68
1.65
31.93
16.0
34.76
1.82
28.53
105.8
5.6
6.0
1.7
4.0
27.40
18.45
0.67
1.52
32.60
18.0
36.67
1.87
30.28
107.9
5.7
8.0
3.5
8.1
27.96
18.76
0.67
1.46
32.95
19.1
37.70
1.90
31.23
109.0
5.8
4.0
0.3
0.7
24.51
16.80
0.69
1.88
30.92
13.0
38.05
1.91
31.54
109.4
5.8
6.0
1.8
4.2
25.59
17.43
0.68
1.74
31.52
14.7
40.07
1.96
33.38
111.5
6.0
8.0
3.2
7.4
26.15
17.74
0.68
1.67
31.84
15.7
41.13
1.99
34.34
112.7
6.1
4.0
0.3
0.6
22.72
15.77
0.69
2.15
30.05
10.6
6.0
1.6
3.7
23.76
16.37
0.69
1.99
30.54
12.0
8.0
3.0
6.9
24.30
16.68
0.69
1.91
30.81
12.7
4.0
0.2
0.5
21.00
14.77
0.70
2.47
29.41
8.5
6.0
1.6
3.7
21.96
15.33
0.70
2.28
29.74
9.6
8.0
2.9
6.7
22.47
15.62
0.70
2.19
29.95
10.3
4.0
0.2
0.4
19.39
13.84
0.71
2.84
29.07
6.8
6.0
1.0
2.3
20.26
14.34
0.71
2.62
29.21
7.7
8.0
2.8
6.6
20.73
14.61
0.70
2.52
29.33
8.2
GPM
WPD Adder
PSI
FT
4.0
0.4
0.9
6.0
0.6
1.3
8.0
0.8
1.8
Operation not recommended
Interpolation is permissible; extrapolation is not.
All entering air conditions are 80В°F DB and 67В°F WB in cooling, and 70В°F DB in heating.
AHRI/ISO certified conditions are 80.6В°F DB and 66.2В°F WB in cooling and 68В°F DB in heating.
Table does not reflect fan or pump power corrections for AHRI/ISO conditions.
All performance is based upon the lower voltage of dual voltage rated units.
Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated.
Operation below 40В°F EWT is based upon a 15% methanol antifreeze solution.
Operation below 60В°F EWT requires optional insulated water/refrigerant circuit.
See performance correction tables for operating conditions other than those listed above.
See Performance Data Selection Notes for operation in the shaded areas.
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 26
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Performance Data – TSL30 with ECM Motor
1000 CFM Nominal (Rated) Airflow
*WPD Adder for
Motorized Valve,
TSL30
(Cv = 10.3,
MOPD = 150 psi)
GPM
WPD Adder
PSI
WPD
0.4
0.9
6.0
0.6
1.3
8.0
0.8
1.8
Cooling - EAT 80/67В°F
EWT
В°F
GPM
4.0
1.2
20
6.0
2.5
8.0
5.2
12.1
4.0
0.9
2.1
33.05
22.48
0.68
1.08
6.0
2.3
5.3
32.29
21.97
0.68
8.0
5.0
11.4
31.79
21.64
0.68
4.0
0.7
1.6
33.55
22.84
6.0
2.3
5.2
33.34
8.0
4.6
10.7
4.0
0.5
6.0
FT
4.0
Performance capacities shown in thousands of Btuh
30
40
50
60
70
80
90
100
110
120
PSI
FT
TC
SC
Sens/Tot
Ratio
kW
Heating - EAT 70В°F
HR
EER
HC
kW
HE
LAT
COP
17.82
1.72
11.96
84.5
3.0
36.75
30.5
20.35
1.76
14.35
86.8
3.4
1.02
35.77
31.7
21.25
1.77
15.20
87.6
3.5
0.99
35.17
32.2
21.74
1.78
15.67
88.1
3.6
0.68
1.20
37.65
27.9
23.88
1.81
17.69
90.1
3.9
22.68
0.68
1.13
37.19
29.6
24.96
1.83
18.71
91.1
4.0
33.12
22.53
0.68
1.09
36.85
30.3
25.54
1.84
19.25
91.6
4.1
1.1
33.29
22.75
0.68
1.33
37.84
25.0
27.28
1.87
20.90
93.2
4.3
2.2
5.1
33.53
22.85
0.68
1.25
37.79
26.9
28.49
1.89
22.05
94.3
4.4
8.0
4.3
9.9
33.56
22.85
0.68
1.21
37.68
27.8
29.14
1.90
22.65
94.9
4.5
4.0
0.4
1.0
32.45
22.34
0.69
1.48
37.51
21.9
30.51
1.92
23.95
96.2
4.6
6.0
2.0
4.6
33.04
22.63
0.68
1.38
37.76
23.9
31.79
1.95
25.16
97.4
4.8
8.0
4.0
9.3
33.26
22.74
0.68
1.34
37.83
24.9
32.47
1.96
25.79
98.0
4.9
4.0
0.4
0.9
31.16
21.69
0.70
1.65
36.81
18.8
33.50
1.97
26.76
98.9
5.0
6.0
1.8
4.1
32.01
22.11
0.69
1.54
37.28
20.7
34.79
2.00
27.97
100.1
5.1
8.0
3.8
8.7
32.38
22.30
0.69
1.49
37.47
21.7
35.45
2.01
28.59
100.7
5.2
4.0
0.3
0.7
29.53
20.87
0.71
1.86
35.88
15.9
36.18
2.02
29.28
101.4
5.2
6.0
1.7
4.0
30.56
21.38
0.70
1.73
36.47
17.7
37.40
2.05
30.42
102.5
5.4
8.0
3.5
8.1
31.04
21.63
0.70
1.67
36.74
18.6
38.00
2.06
30.97
103.1
5.4
4.0
0.3
0.7
27.66
19.95
0.72
2.10
34.83
13.2
38.48
2.07
31.42
103.5
5.5
6.0
1.8
4.2
28.79
20.50
0.71
1.95
35.46
14.7
39.53
2.09
32.40
104.5
5.5
8.0
3.2
7.4
29.35
20.78
0.71
1.88
35.77
15.6
40.02
2.10
32.85
105.0
5.6
4.0
0.3
0.6
25.63
18.96
0.74
2.38
33.76
10.8
6.0
1.6
3.7
26.81
19.53
0.73
2.21
34.37
12.1
8.0
3.0
6.9
27.40
19.82
0.72
2.13
34.68
12.8
4.0
0.2
0.5
23.53
17.95
0.76
2.71
32.79
8.7
6.0
1.6
3.7
24.70
18.51
0.75
2.52
33.31
9.8
8.0
2.9
6.7
25.30
18.80
0.74
2.43
33.60
10.4
4.0
0.2
0.4
21.44
16.97
0.79
3.10
32.03
6.9
6.0
1.0
2.3
22.56
17.49
0.78
2.89
32.41
7.8
8.0
2.8
6.6
23.14
17.77
0.77
2.78
32.63
8.3
Operation not recommended
Operation not recommended
Interpolation is permissible; extrapolation is not.
All entering air conditions are 80В°F DB and 67В°F WB in cooling, and 70В°F DB in heating.
AHRI/ISO certified conditions are 80.6В°F DB and 66.2В°F WB in cooling and 68В°F DB in heating.
Table does not reflect fan or pump power corrections for AHRI/ISO conditions.
All performance is based upon the lower voltage of dual voltage rated units.
Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated.
Operation below 40В°F EWT is based upon a 15% methanol antifreeze solution.
Operation below 60В°F EWT requires optional insulated water/refrigerant circuit.
See performance correction tables for operating conditions other than those listed above.
See Performance Data Selection Notes for operation in the shaded areas.
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 27
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Performance Data – TSL36 with ECM Motor
1200 CFM Nominal (Rated) Airflow
Performance capacities shown in thousands of Btuh
WPD
EWT
В°F
PSI
4.5
20
30
40
50
60
70
80
90
100
110
120
Cooling - EAT 80/67В°F
GPM
FT
TC
SC
Sens/Tot
Ratio
kW
Heating - EAT 70В°F
HR
EER
HC
kW
HE
LAT
COP
23.28
2.22
15.72
85.9
3.1
3.7
6.0
5.0
9.0
8.6
19.8
4.5
2.8
6.4
46.26
30.11
0.65
1.53
51.50
30.2
26.08
2.26
18.36
88.1
3.4
6.0
3.8
8.8
46.26
30.05
0.65
1.46
51.25
31.7
27.35
2.28
19.56
89.1
3.5
9.0
7.4
17.0
46.01
29.82
0.65
1.40
50.77
33.0
28.06
2.29
20.23
89.6
3.6
4.5
1.8
4.3
45.73
29.87
0.65
1.68
51.44
27.3
30.51
2.33
22.56
91.5
3.8
6.0
2.6
5.9
46.11
30.05
0.65
1.59
51.54
29.0
32.12
2.36
24.08
92.7
4.0
9.0
7.0
16.3
46.29
30.11
0.65
1.51
51.45
30.6
33.01
2.37
24.92
93.4
4.1
4.5
0.9
2.1
44.61
29.29
0.66
1.85
50.92
24.1
35.03
2.40
26.83
95.0
4.3
6.0
2.4
5.6
45.31
29.66
0.65
1.75
51.27
25.9
36.94
2.43
28.65
96.4
4.5
9.0
4.7
10.7
45.84
29.93
0.65
1.65
51.49
27.7
38.00
2.45
29.65
97.3
4.5
4.5
0.9
2.0
43.02
28.46
0.66
2.06
50.04
20.9
39.53
2.47
31.09
98.4
4.7
6.0
2.3
5.3
43.97
28.95
0.66
1.94
50.57
22.7
41.72
2.51
33.15
100.1
4.9
9.0
4.4
10.3
44.79
29.38
0.66
1.82
51.01
24.6
42.91
2.53
34.28
101.0
5.0
4.5
0.8
1.8
41.06
27.44
0.67
2.31
48.94
17.8
43.95
2.55
35.25
101.8
5.1
6.0
2.2
5.1
42.18
28.02
0.66
2.17
49.57
19.5
46.34
2.60
37.48
103.7
5.2
9.0
4.3
10.0
43.23
28.56
0.66
2.03
50.16
21.3
47.62
2.62
38.67
104.7
5.3
4.5
0.8
1.8
38.78
26.29
0.68
2.62
47.71
14.8
48.21
2.64
39.21
105.1
5.4
6.0
2.1
4.9
40.04
26.92
0.67
2.45
48.38
16.4
50.69
2.69
41.50
107.0
5.5
9.0
4.2
9.6
41.25
27.54
0.67
2.29
49.05
18.0
52.00
2.73
42.69
108.0
5.6
4.5
0.8
1.8
36.27
25.06
0.69
2.99
46.46
12.1
52.19
2.73
42.87
108.2
5.6
6.0
2.1
4.9
37.61
25.71
0.68
2.79
47.11
13.5
54.65
2.81
45.08
110.1
5.7
9.0
4.0
9.3
38.93
26.37
0.68
2.60
47.79
15.0
55.89
2.85
46.17
111.0
5.8
4.5
0.7
1.7
33.58
23.77
0.71
3.43
45.27
9.8
6.0
2.1
4.8
34.97
24.43
0.70
3.19
45.86
11.0
9.0
3.9
9.1
36.35
25.10
0.69
2.97
46.50
12.2
4.5
0.7
1.5
30.78
22.45
0.73
3.95
44.25
7.8
6.0
2.0
4.6
32.18
23.10
0.72
3.68
44.73
8.7
9.0
3.9
8.9
33.60
23.77
0.71
3.42
45.28
9.8
4.5
0.6
1.5
27.92
21.12
0.76
4.57
43.50
6.1
6.0
1.9
4.4
29.31
21.77
0.74
4.25
43.83
6.9
9.0
3.6
8.4
30.73
22.42
0.73
3.96
44.23
7.8
*WPD Adder for
Motorized Valve,
TSL36
(Cv = 10.3,
MOPD = 150 psi)
Operation not recommended
GPM
WPD Adder
PSI
FT
4.5
0.4
1.0
6.8
0.7
1.5
9.0
0.9
2.0
Operation not recommended
Interpolation is permissible; extrapolation is not.
All entering air conditions are 80В°F DB and 67В°F WB in cooling, and 70В°F DB in heating.
AHRI/ISO certified conditions are 80.6В°F DB and 66.2В°F WB in cooling and 68В°F DB in heating.
Table does not reflect fan or pump power corrections for AHRI/ISO conditions.
All performance is based upon the lower voltage of dual voltage rated units.
Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated.
Operation below 40В°F EWT is based upon a 15% methanol antifreeze solution.
Operation below 60В°F EWT requires optional insulated water/refrigerant circuit.
See performance correction tables for operating conditions other than those listed above.
See Performance Data Selection Notes for operation in the shaded areas.
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 28
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Performance Data – TSL09 with Modulating Valve or Variable Speed Pump
400 CFM Nominal Airflow Heating, 350 CFM Nominal Airflow Cooling
EWT
В°F
WPD
Cooling - EAT 80/67В°F
WPD
GPM
PSI
FT
TC
SC
kW
HR
EER
LWT
PSI
FT
1.0
0.7
1.6
13.10
9.16
0.45
14.62
29.4
60
3.0
5.7
13.2
6.18
0.65
3.96
75.6
2.8
17
1.5
1.1
2.5
7.21
0.66
4.95
76.9
3.2
23
1.0
0.7
1.6
13.10
9.16
0.45
14.62
29.4
60
2.3
1.0
0.7
1.6
13.10
9.16
0.45
14.62
29.4
60
3.0
1.8
4.2
7.55
0.67
5.28
77.3
3.3
25
4.7
10.9
7.74
0.67
5.46
77.5
3.4
26
1.5
1.4
3.3
13.10
9.16
0.45
14.62
29.4
60
1.5
1.4
3.3
13.10
9.16
0.45
14.62
29.4
60
1.5
0.8
1.8
8.69
0.68
6.39
78.7
3.8
31
2.3
1.7
3.9
9.16
0.68
6.84
79.3
3.9
1.5
1.4
3.3
13.10
9.16
0.45
14.62
29.4
34
60
3.0
4.1
9.5
9.42
0.68
7.09
79.6
4.0
1.5
0.5
1.1
12.74
9.12
0.49
14.42
35
25.9
69
1.5
0.5
1.1
10.24
0.69
7.89
91.6
4.4
2.3
1.6
3.7
13.01
9.17
0.46
39
14.58
28.3
63
2.3
1.6
3.7
10.83
0.69
8.47
93.0
4.6
42
2.9
3.6
8.4
13.10
9.16
1.5
0.4
1.0
12.16
8.93
0.45
14.62
29.4
60
3.0
3.6
8.4
11.12
0.69
8.75
93.7
4.7
44
0.55
14.03
22.1
79
1.5
0.4
1.0
11.80
0.70
9.42
95.3
5.0
2.3
1.5
3.5
12.55
47
9.06
0.51
14.29
24.5
73
2.3
1.5
3.5
12.50
0.70
10.11
96.9
5.2
3.0
4.0
9.3
51
12.72
9.11
0.49
14.40
25.7
70
3.0
4.0
9.3
12.89
0.70
10.49
97.8
5.4
1.5
0.4
53
0.9
11.43
8.63
0.62
13.53
18.6
88
1.5
0.4
0.9
13.35
0.71
10.94
98.8
5.5
2.3
55
1.4
3.3
11.89
8.82
0.57
13.85
20.7
82
2.3
1.4
3.3
14.13
0.71
11.71
100.6
5.8
60
3.0
3.0
7.0
12.11
8.91
0.55
14.00
21.9
79
3.0
3.0
7.0
14.56
0.71
12.13
101.6
6.0
62
1.5
0.3
0.8
10.61
8.27
0.69
12.95
15.5
97
1.5
0.3
0.8
14.83
0.71
12.40
102.3
6.1
63
2.3
1.3
3.1
11.10
8.49
0.64
13.30
17.3
92
2.3
1.3
3.1
15.66
0.72
13.22
104.2
6.4
68
3.0
3.1
7.1
11.27
8.56
0.63
13.41
17.9
90
2.7
3.1
7.1
15.95
0.72
13.50
104.8
6.5
70
1.5
0.3
0.7
9.75
7.89
0.76
12.34
12.9
106
1.4
0.2
0.5
15.95
0.72
13.50
104.8
6.5
70
2.3
1.5
3.5
9.75
7.89
0.76
12.34
12.9
106
1.4
0.2
0.5
15.95
0.72
13.50
104.8
6.5
70
3.0
3.1
7.2
9.75
7.89
0.76
12.34
12.9
106
1.4
0.2
0.5
15.95
0.72
13.50
104.8
6.5
70
1.5
0.1
0.2
8.90
7.51
0.83
11.73
10.7
116
0.9
0.1
0.2
15.95
0.72
13.50
104.8
6.5
70
2.3
1.2
2.9
9.35
7.71
0.79
12.06
11.8
111
0.9
0.1
0.2
15.95
0.72
13.50
104.8
6.5
70
3.0
2.8
6.4
9.59
7.82
0.77
12.23
12.4
108
0.9
0.1
0.2
15.95
0.72
13.50
104.8
6.5
70
1.5
0.1
0.2
8.10
7.16
0.90
11.18
9.0
125
0.7
0.1
0.2
15.95
0.72
13.50
104.8
6.5
70
2.3
1.2
2.8
8.50
7.33
0.87
11.45
9.8
120
0.7
0.1
0.2
15.95
0.72
13.50
104.8
6.5
70
3.0
2.7
6.2
8.71
7.42
0.85
11.60
10.3
118
0.7
0.1
0.2
15.95
0.72
13.50
104.8
6.5
70
1.5
0.1
0.2
7.39
6.91
0.97
10.70
7.6
134
0.5
0.1
0.2
15.95
0.72
13.50
104.8
6.5
70
2.3
1.2
2.7
7.72
7.02
0.94
10.92
8.2
130
0.5
0.1
0.2
15.95
0.72
13.50
104.8
6.5
70
3.0
2.6
6.0
7.90
7.09
0.92
11.04
8.6
127
0.5
0.1
0.2
15.95
0.72
13.50
104.8
6.5
70
20
30
40
50
60
70
80
90
100
110
120
Heating - EAT 70ВєF
GPM
HC
kW
HE
LAT
COP
LWT
Interpolation is permissible; extrapolation is not.
All entering air conditions are 80В°F DB and 67В°F WB in cooling, and 70В°F DB in heating.
AHRI/ISO certified conditions are 80.6В°F DB and 66.2В°F WB in cooling and 68В°F DB in heating.
Table does not reflect fan or pump power corrections for AHRI/ISO conditions.
All performance is based upon the lower voltage of dual voltage rated units.
Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated.
Operation below 40В°F EWT is based upon a 15% methanol antifreeze solution.
Operation below 60В°F EWT requires optional insulated water/refrigerant circuit.
See performance correction tables for operating conditions other than those listed above.
See Performance Data Selection Notes for operation in the shaded areas.
Water Pressure drop adder for modulating pump option see table on page 37.
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 29
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Performance Data – TSL12 with Modulating Valve or Variable Speed Pump
400 CFM Nominal Airflow Heating, 500 CFM Nominal Airflow Cooling
EWT
В°F
WPD
Cooling - EAT 80/67В°F
WPD
GPM
PSI
FT
TC
SC
kW
HR
EER
LWT
20
30
40
50
60
70
80
90
100
110
120
Heating - EAT 70ВєF
GPM
PSI
FT
HC
kW
HE
LAT
COP
LWT
3.5
9.4
21.7
7.76
0.77
5.13
83.9
2.9
17
1.1
1.1
2.6
15.10
9.86
0.51
16.85
29.6
60
1.8
3.4
7.9
8.92
0.79
6.23
86.3
3.3
23
1.1
1.1
2.6
15.10
9.86
0.51
16.85
29.6
60
2.6
5.6
12.9
9.25
0.79
6.54
87.0
3.4
25
1.1
1.1
2.6
15.10
9.86
0.51
16.85
29.6
60
3.5
7.8
18.0
9.43
0.80
6.71
87.4
3.5
26
1.7
2.3
5.3
15.10
9.86
0.51
16.85
29.6
60
1.8
2.9
6.7
10.50
0.81
7.72
89.6
3.8
31
1.7
2.3
5.3
15.10
9.86
0.51
16.85
29.6
60
2.6
4.9
11.3
10.92
0.82
8.12
90.4
3.9
34
1.7
2.3
5.3
15.10
9.86
0.51
16.85
29.6
60
3.5
6.2
14.3
11.16
0.83
8.34
90.9
4.0
35
1.8
2.3
5.3
14.58
9.66
0.58
16.55
25.3
69
1.8
2.3
5.3
12.74
0.87
9.77
91.5
4.3
39
2.6
4.2
9.7
14.95
9.81
0.53
16.77
28.1
63
2.6
4.2
9.7
13.49
0.88
10.49
92.9
4.5
42
3.3
7.7
17.8
15.10
9.86
0.51
16.85
29.6
60
3.5
7.7
17.8
13.85
0.88
10.83
93.6
4.6
43
1.8
2.3
5.3
13.87
9.34
0.65
16.09
21.3
78
1.8
2.3
5.3
14.64
0.89
11.59
95.0
4.8
47
2.6
4.1
9.5
14.33
9.55
0.60
16.39
23.8
73
2.6
4.1
9.5
15.54
0.90
12.46
96.7
5.0
50
3.5
6.9
15.9
14.55
9.65
0.58
16.52
25.1
69
3.5
6.9
15.9
16.05
0.91
12.95
97.7
5.2
53
1.8
2.2
5.2
13.04
8.95
0.73
15.53
17.9
88
1.8
2.2
5.2
16.55
0.92
13.42
98.6
5.3
55
2.6
4.0
9.1
13.55
9.20
0.68
15.87
19.9
82
2.6
4.0
9.1
17.58
0.93
14.42
100.5
5.6
59
3.5
6.2
14.3
13.80
9.31
0.66
16.04
21.0
79
3.5
6.2
14.3
18.16
0.93
14.98
101.5
5.7
61
1.8
2.1
4.9
12.14
8.51
0.81
14.92
14.9
97
1.8
2.1
4.9
18.42
0.93
15.23
102.0
5.8
63
2.6
3.9
8.9
12.67
8.77
0.76
15.28
16.6
92
2.6
3.9
8.9
19.55
0.95
16.33
104.1
6.1
68
3.5
5.6
13.0
12.94
8.90
0.74
15.46
17.5
89
3.4
5.6
13.0
20.11
0.95
16.87
105.2
6.2
70
1.8
2.1
4.8
11.20
8.05
0.90
14.29
12.4
106
1.7
1.8
4.2
20.11
0.95
16.87
105.2
6.2
70
2.6
3.7
8.7
11.72
8.31
0.85
14.64
13.7
101
1.7
1.8
4.2
20.11
0.95
16.87
105.2
6.2
70
3.5
5.5
12.7
12.00
8.44
0.83
14.82
14.5
98
1.7
1.8
4.2
20.11
0.95
16.87
105.2
6.2
70
1.8
1.9
4.4
10.28
7.60
1.00
13.68
10.3
116
1.1
0.5
1.2
20.11
0.95
16.87
105.2
6.2
70
2.6
3.4
7.8
10.77
7.84
0.95
14.00
11.4
111
1.1
0.5
1.2
20.11
0.95
16.87
105.2
6.2
70
3.5
5.4
12.4
11.03
7.97
0.92
14.17
12.0
108
1.1
0.5
1.2
20.11
0.95
16.87
105.2
6.2
70
1.8
1.8
4.2
9.41
7.18
1.09
13.13
8.6
125
0.8
0.1
0.2
20.11
0.95
16.87
105.2
6.2
70
2.6
3.3
7.7
9.84
7.39
1.04
13.40
9.4
120
0.8
0.1
0.2
20.11
0.95
16.87
105.2
6.2
70
3.5
5.3
12.2
10.08
7.50
1.02
13.55
9.9
118
0.8
0.1
0.2
20.11
0.95
16.87
105.2
6.2
70
1.8
1.8
4.1
8.63
6.84
1.19
12.70
7.2
135
0.7
0.1
0.2
20.11
0.95
16.87
105.2
6.2
70
2.6
3.3
7.5
8.99
7.00
1.14
12.89
7.9
130
0.7
0.1
0.2
20.11
0.95
16.87
105.2
6.2
70
3.5
5.2
11.9
9.19
7.09
1.12
13.01
8.2
127
0.7
0.1
0.2
20.11
0.95
16.87
105.2
6.2
70
Interpolation is permissible; extrapolation is not.
All entering air conditions are 80В°F DB and 67В°F WB in cooling, and 70В°F DB in heating.
AHRI/ISO certified conditions are 80.6В°F DB and 66.2В°F WB in cooling and 68В°F DB in heating.
Table does not reflect fan or pump power corrections for AHRI/ISO conditions.
All performance is based upon the lower voltage of dual voltage rated units.
Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated.
Operation below 40В°F EWT is based upon a 15% methanol antifreeze solution.
Operation below 60В°F EWT requires optional insulated water/refrigerant circuit.
See performance correction tables for operating conditions other than those listed above.
See Performance Data Selection Notes for operation in the shaded areas.
Water Pressure drop adder for modulating pump option see table on page 37.
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 30
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Performance Data – TSL15 with Modulating Valve or Variable Speed Pump
600 CFM Nominal Airflow Heating, 600 CFM Nominal Airflow Cooling
EWT
В°F
WPD
Cooling - EAT 80/67В°F
WPD
GPM
PSI
FT
TC
SC
kW
HR
EER
LWT
PSI
FT
1.3
1.8
4.2
17.75
11.82
0.58
19.74
30.5
60
4.5
8.8
20.3
8.99
0.83
6.15
81.8
3.2
17
2.3
2.3
5.3
10.14
0.86
7.51
84.1
3.6
23
1.3
1.8
4.2
17.75
11.82
0.58
19.74
30.5
60
3.5
1.3
1.8
4.2
17.75
11.82
0.58
19.74
30.5
60
4.5
5.0
11.6
10.61
0.87
7.95
84.8
3.7
25
8.3
19.2
10.86
0.87
8.19
85.2
3.8
2.0
2.2
5.1
17.75
11.82
0.58
19.74
30.5
60
26
2.3
2.2
5.1
12.11
0.89
9.37
87.1
4.1
32
2.0
2.2
5.1
17.75
11.82
0.58
19.74
30.5
2.0
2.2
5.1
17.75
11.82
0.58
19.74
30.5
60
3.5
4.3
9.9
12.68
0.90
9.91
88.0
4.2
34
60
4.5
7.7
17.8
12.99
0.90
10.21
88.5
4.3
2.3
2.1
4.8
17.67
12.19
0.64
19.85
35
27.6
68
2.3
2.1
4.8
14.34
0.92
11.20
90.1
4.6
40
3.5
4.2
9.7
17.75
11.90
0.59
19.77
30.0
61
3.5
4.2
9.7
15.06
0.93
11.89
91.2
4.7
43
4.1
7.1
16.4 17.75
11.82
2.3
2.1
4.9
17.22
12.43
0.58
19.74
30.5
60
4.1
7.1
16.4
15.26
0.93
12.07
91.5
4.8
44
0.73
19.70
23.7
78
2.3
2.1
4.9
16.24
0.95
13.01
93.0
5.0
3.5
4.2
9.7
17.54
48
12.32
0.67
19.83
26.1
71
3.5
4.2
9.7
17.06
0.96
13.79
94.3
5.2
4.5
7.0
52
16.1 17.63
12.24
0.65
19.85
27.1
69
4.5
7.0
16.1
17.41
0.96
14.12
94.8
5.3
54
2.3
3.5
2.0
4.7
16.45
12.32
0.82
19.25
20.1
87
2.3
2.0
4.7
18.09
0.97
14.78
95.9
5.5
57
4.2
9.6
16.97
12.43
0.76
19.57
22.3
81
3.5
4.2
9.6
18.99
0.98
15.64
97.2
5.7
61
4.5
6.9
15.8 17.14
12.44
0.74
19.66
23.2
79
4.5
6.9
15.8
19.38
0.99
16.01
97.8
5.8
63
2.3
2.0
4.5
15.39
11.81
0.92
18.54
16.7
96
3.5
3.4
7.9
20.86
1.00
17.45
100.1
6.1
70
3.5
4.0
9.2
16.07
12.16
0.86
19.00
18.7
91
3.5
3.4
7.9
20.86
1.00
17.45
100.1
6.1
70
4.5
6.6
15.3 16.31
12.27
0.83
19.16
19.5
89
3.5
3.4
7.9
20.86
1.00
17.45
100.1
6.1
70
2.3
1.9
4.4
14.08
10.89
1.03
17.57
13.7
106
1.8
1.8
4.2
20.87
1.00
17.46
100.1
6.1
70
3.5
3.9
9.0
14.87
11.47
0.96
18.16
15.4
100
1.8
1.8
4.2
20.87
1.00
17.46
100.1
6.1
70
4.5
6.6
15.3 15.17
11.67
0.94
18.38
16.1
98
1.8
1.8
4.2
20.87
1.00
17.46
100.1
6.1
70
2.3
1.9
4.4
12.53
9.59
1.13
16.39
11.1
115
1.2
0.6
1.4
20.87
1.00
17.46
100.1
6.1
70
3.5
3.9
8.9
13.39
10.34
1.07
17.06
12.5
110
1.2
0.6
1.4
20.87
1.00
17.46
100.1
6.1
70
4.5
6.5
15.0 13.74
10.62
1.05
17.32
13.1
108
1.2
0.6
1.4
20.87
1.00
17.46
100.1
6.1
70
2.3
1.9
4.4
10.77
7.97
1.24
15.00
8.7
123
0.9
0.2
0.5
20.87
1.00
17.46
100.1
6.1
70
3.5
3.9
8.9
11.67
8.81
1.19
15.72
9.8
119
0.9
0.2
0.5
20.87
1.00
17.46
100.1
6.1
70
4.5
6.4
14.8 12.04
9.15
1.16
16.01
10.3
117
0.9
0.2
0.5
20.87
1.00
17.46
100.1
6.1
70
2.3
1.9
4.4
8.83
6.14
1.35
13.43
6.5
132
0.7
0.1
0.2
20.87
1.00
17.46
100.1
6.1
70
3.5
3.8
8.8
9.73
6.98
1.30
14.16
7.5
128
0.7
0.1
0.2
20.87
1.00
17.46
100.1
6.1
70
4.5
6.3
14.6 10.10
7.33
1.28
14.46
7.9
126
0.7
0.1
0.2
20.87
1.00
17.46
100.1
6.1
70
20
30
40
50
60
70
80
90
100
110
120
Heating - EAT 70ВєF
GPM
HC
kW
HE
LAT
COP
LWT
Interpolation is permissible; extrapolation is not.
All entering air conditions are 80В°F DB and 67В°F WB in cooling, and 70В°F DB in heating.
AHRI/ISO certified conditions are 80.6В°F DB and 66.2В°F WB in cooling and 68В°F DB in heating.
Table does not reflect fan or pump power corrections for AHRI/ISO conditions.
All performance is based upon the lower voltage of dual voltage rated units.
Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated.
Operation below 40В°F EWT is based upon a 15% methanol antifreeze solution.
Operation below 60В°F EWT requires optional insulated water/refrigerant circuit.
See performance correction tables for operating conditions other than those listed above.
See Performance Data Selection Notes for operation in the shaded areas.
Water Pressure drop adder for modulating pump option see table on page 37.
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 31
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Performance Data – TSL18 with Modulating Valve or Variable Speed Pump
700 CFM Nominal Airflow Heating, 700 CFM Nominal Airflow Cooling
EWT
В°F
WPD
Cooling - EAT 80/67В°F
WPD
GPM
PSI
FT
TC
SC
kW
HR
EER
LWT
PSI
FT
HC
COP
LWT
1.7
0.3
0.7
22.88
15.85
0.75
25.43
30.5
60
6.8
7.2
16.6
10.66
1.03
7.15
3.4
2.2
5.1
11.47
1.04
7.91
82.1
3.0
17.9
83.1
3.2
1.7
0.3
0.7
22.88
15.85
0.75
25.43
30.5
60
5.1
4.2
9.7
11.47
1.04
7.91
21
83.1
3.2
1.7
0.3
0.7
22.88
15.85
0.75
25.43
30.5
60
6.8
6.7
15.5
11.47
1.04
21
7.91
83.1
3.2
2.6
0.4
0.9
22.88
15.85
0.75
25.43
30.5
60
3.4
1.9
4.4
14.65
21
1.10
10.91
87.3
3.9
2.6
0.4
0.9
22.88
15.85
0.75
25.43
30.5
60
5.1
3.8
8.8
31
14.65
1.10
10.91
87.3
3.9
2.6
0.4
0.9
22.88
15.85
0.75
25.43
30.5
60
6.8
5.4
31
12.5
14.65
1.10
10.91
87.3
3.9
3.4
0.5
1.2
22.46
15.70
0.80
25.18
28.2
60
3.4
1.5
31
3.5
17.82
1.14
13.92
91.5
4.6
42
5.1
1.7
3.9
5.1
2.8
6.5
22.87
15.84
0.75
25.43
30.5
60
5.1
22.87
15.84
0.75
25.43
30.5
60
6.8
3.3
7.6
18.57
1.15
14.64
92.5
4.7
44
4.4
10.2
18.57
1.15
14.64
92.5
4.7
3.4
1.5
3.5
21.49
15.22
0.90
24.56
23.8
74
44
3.4
1.5
3.5
20.46
1.18
16.43
95.0
5.1
50
5.1
6.8
2.9
6.7
21.99
15.48
0.85
24.88
25.9
4.3
9.9
22.22
15.60
0.82
25.04
27.0
70
5.1
2.9
6.7
21.35
1.19
17.29
96.2
5.3
53
67
6.8
4.3
9.9
21.84
1.20
17.75
96.8
5.3
3.4
1.4
3.2
20.34
14.55
1.01
23.80
55
20.1
84
3.4
1.4
3.2
23.10
1.22
18.95
98.5
5.6
5.1
2.4
5.5
20.90
14.89
0.96
59
24.17
21.8
79
5.1
2.4
5.5
24.13
1.23
19.93
99.8
5.8
6.8
4.2
9.7
21.18
15.05
62
0.93
24.36
22.7
77
6.8
4.2
9.7
24.68
1.24
20.46
100.6
5.8
64
3.4
1.1
2.5
19.06
5.1
2.6
6.0
19.66
13.78
1.14
22.93
16.8
93
3.4
1.1
2.5
25.72
1.25
21.45
101.9
6.0
67
14.14
1.08
23.34
18.2
91
4.5
2.2
5.1
26.52
1.26
22.21
103.0
6.2
6.8
4.1
9.5
70
19.96
14.32
1.05
23.54
19.0
91
4.5
2.2
5.1
26.52
1.26
22.21
103.0
6.2
70
3.4
1.1
5.1
2.8
2.5
17.67
12.95
1.27
22.00
13.9
110
2.2
2.0
4.6
26.52
1.26
22.21
103.0
6.2
70
6.5
18.29
13.31
1.21
22.42
15.1
110
2.2
2.0
4.6
26.52
1.26
22.21
103.0
6.2
6.8
70
4.0
9.2
18.60
13.50
1.18
22.63
15.8
110
2.2
2.0
4.6
26.52
1.26
22.21
103.0
6.2
70
3.4
1.1
2.5
16.21
12.12
1.42
21.04
11.5
112
1.5
0.9
2.1
26.52
1.26
22.21
103.0
6.2
70
5.1
2.2
5.1
16.83
12.46
1.35
21.45
12.4
108
1.5
0.9
2.1
26.52
1.26
22.21
103.0
6.2
70
6.8
3.6
8.3
17.15
12.64
1.32
21.65
13.0
106
1.5
0.9
2.1
26.52
1.26
22.21
103.0
6.2
70
3.4
1.0
2.3
14.70
11.31
1.57
20.07
9.4
122
1.1
0.5
1.2
26.52
1.26
22.21
103.0
6.2
70
5.1
2.1
4.9
15.31
11.63
1.51
20.46
10.2
118
1.1
0.5
1.2
26.52
1.26
22.21
103.0
6.2
70
6.8
3.5
8.1
15.62
11.80
1.48
20.66
10.6
116
1.1
0.5
1.2
26.52
1.26
22.21
103.0
6.2
70
3.4
1.0
2.3
13.19
10.56
1.74
19.13
7.6
131
0.9
0.2
0.5
26.52
1.26
22.21
103.0
6.2
70
5.1
2.1
4.9
13.77
10.84
1.68
19.48
8.2
128
0.9
0.2
0.5
26.52
1.26
22.21
103.0
6.2
70
6.8
3.5
8.1
14.06
10.99
1.64
19.67
8.6
126
0.9
0.2
0.5
26.52
1.26
22.21
103.0
6.2
70
20
30
40
50
60
70
80
90
100
110
120
Heating - EAT 70ВєF
GPM
kW
HE
LAT
Interpolation is permissible; extrapolation is not.
All entering air conditions are 80В°F DB and 67В°F WB in cooling, and 70В°F DB in heating.
AHRI/ISO certified conditions are 80.6В°F DB and 66.2В°F WB in cooling and 68В°F DB in heating.
Table does not reflect fan or pump power corrections for AHRI/ISO conditions.
All performance is based upon the lower voltage of dual voltage rated units.
Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated.
Operation below 40В°F EWT is based upon a 15% methanol antifreeze solution.
Operation below 60В°F EWT requires optional insulated water/refrigerant circuit.
See performance correction tables for operating conditions other than those listed above.
See Performance Data Selection Notes for operation in the shaded areas.
Water Pressure drop adder for modulating pump option see table on page 37.
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 32
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Performance Data – TSL24 with Modulating Valve or Variable Speed Pump
850 CFM Nominal Airflow Heating, 850 CFM Nominal Airflow Cooling
EWT
В°F
WPD
Cooling - EAT 80/67В°F
WPD
GPM
PSI
FT
TC
SC
kW
HR
EER
LWT
PSI
FT
COP
LWT
2.4
0.5
1.2
32.76
21.27
1.01
36.21
32.3
60
8.0
5.2
12.0
13.86
1.73
7.94
4.0
0.9
2.1
17.35
1.67
11.67
83.1
2.3
18.0
86.9
3.1
2.4
0.5
1.2
32.76
21.27
1.01
36.21
32.3
60
6.0
2.3
5.3
18.24
1.65
12.60
24
87.8
3.2
2.4
0.5
1.2
32.76
21.27
1.01
36.21
32.3
60
8.0
5.0
11.6
18.73
1.65
26
13.11
88.4
3.3
3.7
0.7
1.6
32.76
21.27
1.01
36.22
32.3
60
4.0
0.7
1.6
21.45
27
1.63
15.90
91.3
3.9
32
3.7
0.7
1.6
32.76
21.27
1.01
3.7
0.7
1.6
32.76
21.27
1.01
36.22
32.3
60
6.0
2.3
5.3
36.22
32.3
60
8.0
4.6
10.6
22.57
1.63
17.02
92.5
4.1
34
23.17
1.63
17.62
93.2
4.2
4.0
0.5
1.1
31.60
20.72
1.12
35.42
28.3
68
4.0
0.5
36
1.2
25.28
1.64
19.70
95.5
4.5
40
6.0
2.2
5.1
32.45
21.13
1.04
36.01
31.2
62
6.0
2.2
5.1
26.56
1.65
20.94
96.9
4.7
43
7.4
4.0
9.2
4.0
0.4
1.0
32.76
21.27
1.01
36.22
32.3
60
30.07
19.92
1.26
34.35
23.9
77
8.0
4.3
9.9
27.25
1.66
21.60
97.6
4.8
45
4.0
0.4
1.0
28.88
1.68
23.15
99.4
5.0
6.0
2.0
4.6
30.98
20.40
1.17
34.98
26.4
48
72
6.0
2.0
4.6
30.29
1.71
24.46
100.9
5.2
52
8.0
4.0
4.0
9.3
31.43
20.63
1.13
35.29
0.4
0.9
28.42
19.02
1.41
33.24
27.7
69
8.0
4.0
9.3
31.04
1.72
25.16
101.7
5.3
54
20.1
87
4.0
0.4
0.9
32.28
1.75
26.31
103.1
5.4
6.0
1.8
4.1
29.36
19.54
1.32
57
33.87
22.2
81
6.0
1.8
4.1
33.81
1.79
27.70
104.7
5.5
61
8.0
3.8
8.7
29.83
19.80
4.0
0.3
0.7
26.69
18.04
1.28
34.19
23.4
79
7.0
3.8
8.7
34.62
1.81
28.44
105.6
5.6
63
1.60
32.14
16.7
96
4.0
0.3
0.7
35.56
1.84
29.29
106.6
5.7
6.0
1.7
4.0
27.64
65
18.58
1.49
32.74
18.5
91
6.0
1.7
4.0
37.21
1.89
30.78
108.4
5.8
8.0
3.5
8.1
70
28.12
18.85
1.44
33.05
19.5
91
6.2
1.7
3.9
37.32
1.89
30.88
108.6
5.8
4.0
0.3
70
0.7
24.92
17.03
1.82
31.13
13.7
110
3.1
0.2
0.5
37.32
1.89
30.88
108.6
5.8
6.0
70
1.8
4.2
25.86
17.56
1.70
31.65
15.2
110
3.1
0.2
0.5
37.32
1.89
30.88
108.6
5.8
70
8.0
3.2
7.4
26.34
17.84
1.64
31.93
16.1
111
3.1
0.2
0.5
37.32
1.89
30.88
108.6
5.8
70
4.0
0.3
0.6
23.15
16.01
2.08
30.26
11.1
115
2.1
0.1
0.2
37.32
1.89
30.88
108.6
5.8
70
6.0
1.6
3.7
24.06
16.53
1.94
30.68
12.4
110
2.1
0.1
0.2
37.32
1.89
30.88
108.6
5.8
70
8.0
3.0
6.9
24.52
16.80
1.87
30.92
13.1
108
2.1
0.1
0.2
37.32
1.89
30.88
108.6
5.8
70
4.0
0.2
0.5
21.40
15.01
2.40
29.60
8.9
125
1.5
0.1
0.2
37.32
1.89
30.88
108.6
5.8
70
6.0
1.6
3.7
22.27
15.50
2.24
29.90
10.0
120
1.5
0.1
0.2
37.32
1.89
30.88
108.6
5.8
70
8.0
2.9
6.7
22.71
15.76
2.16
30.07
10.5
118
1.5
0.1
0.2
37.32
1.89
30.88
108.6
5.8
70
4.0
0.2
0.4
19.73
14.08
2.79
29.24
7.1
135
1.2
0.1
0.2
37.32
1.89
30.88
108.6
5.8
70
6.0
1.0
2.3
20.54
14.53
2.59
29.38
7.9
130
1.2
0.1
0.2
37.32
1.89
30.88
108.6
5.8
70
8.0
2.8
6.6
20.95
14.76
2.50
29.48
8.4
127
1.2
0.1
0.2
37.32
1.89
30.88
108.6
5.8
70
20
30
40
50
60
70
80
90
100
110
120
Heating - EAT 70ВєF
GPM
HC
kW
HE
LAT
Interpolation is permissible; extrapolation is not.
All entering air conditions are 80В°F DB and 67В°F WB in cooling, and 70В°F DB in heating.
AHRI/ISO certified conditions are 80.6В°F DB and 66.2В°F WB in cooling and 68В°F DB in heating.
Table does not reflect fan or pump power corrections for AHRI/ISO conditions.
All performance is based upon the lower voltage of dual voltage rated units.
Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated.
Operation below 40В°F EWT is based upon a 15% methanol antifreeze solution.
Operation below 60В°F EWT requires optional insulated water/refrigerant circuit.
See performance correction tables for operating conditions other than those listed above.
See Performance Data Selection Notes for operation in the shaded areas.
Water Pressure drop adder for modulating pump option see table on page 37.
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 33
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Performance Data – TSL30 with Modulating Valve or Variable Speed Pump
1000 CFM Nominal Airflow Heating, 1000 CFM Nominal Airflow Cooling
EWT
В°F
WPD
Cooling - EAT 80/67В°F
WPD
GPM
PSI
FT
TC
SC
kW
HR
EER
LWT
PSI
FT
2.5
0.5
1.1
33.42
22.73
1.22
37.56
27.5
60
8.0
5.2
12.0
17.82
1.72
11.96
84.5
3.0
17
4.0
0.9
2.1
18.94
1.74
13.02
85.5
3.2
20
2.5
0.5
1.1
33.42
22.73
1.22
37.56
27.5
60
6.0
2.3
5.3
18.94
1.74
13.02
85.5
3.2
20
2.5
0.5
1.1
33.42
22.73
1.22
37.56
27.5
3.8
0.7
1.6
33.42
22.73
1.22
37.56
27.5
60
8.0
5.0
11.6
18.94
1.74
13.02
85.5
3.2
20
60
4.0
0.7
1.6
23.68
1.81
17.50
89.9
3.8
3.8
0.7
1.6
33.42
22.73
1.22
37.56
31
27.5
60
6.0
2.3
5.3
23.68
1.81
17.50
89.9
3.8
3.8
0.7
1.6
33.42
22.73
1.22
31
37.56
27.5
60
8.0
4.6
10.6
23.68
1.81
17.50
89.9
3.8
4.0
0.5
1.1
33.35
22.92
31
1.33
37.89
25.0
69
4.0
0.5
1.2
27.28
1.87
20.90
93.2
4.3
40
6.0
2.2
5.1
33.47
7.5
4.3
9.9
33.42
22.83
1.25
37.72
26.8
63
6.0
2.2
5.1
28.49
1.89
22.05
94.3
4.4
43
22.73
1.22
37.56
27.5
60
8.0
4.3
9.9
29.01
1.90
22.54
94.8
4.5
4.0
0.4
1.0
44
32.55
22.62
1.48
37.60
21.9
79
4.0
0.4
0.9
30.51
1.92
23.95
96.2
4.6
6.0
2.0
48
4.6
33.13
22.86
1.39
37.85
23.9
73
6.0
2.0
4.6
31.79
1.95
25.16
97.4
4.8
8.0
52
4.0
9.3
33.32
22.91
1.34
37.89
24.9
69
8.0
4.0
9.2
32.47
1.96
25.79
98.0
4.9
54
4.0
0.4
0.9
31.19
21.95
1.66
36.85
18.8
88
4.0
0.4
0.9
33.50
1.97
26.76
98.9
5.0
57
6.0
1.8
4.1
32.09
22.41
1.55
37.36
20.8
82
6.0
1.8
4.2
34.79
2.00
27.97
100.1
5.1
61
8.0
3.8
8.7
32.48
22.59
1.49
37.57
21.8
79
8.0
3.8
8.8
35.45
2.01
28.59
100.7
5.2
63
4.0
0.3
0.7
29.46
21.03
1.86
35.81
15.8
98
4.0
0.3
0.7
36.18
2.02
29.28
101.4
5.2
65
6.0
1.7
4.0
30.55
21.61
1.73
36.46
17.6
92
6.1
1.8
4.2
37.43
2.05
30.44
102.6
5.4
70
8.0
3.5
8.1
31.07
21.88
1.67
36.77
18.6
89
6.1
1.8
4.2
37.43
2.05
30.44
102.6
5.4
70
4.0
0.3
0.7
27.50
19.98
2.10
34.67
13.1
107
3.1
0.3
0.7
37.43
2.05
30.44
102.6
5.4
70
6.0
1.8
4.2
28.68
20.61
1.95
35.34
14.7
102
3.1
0.3
0.7
37.43
2.05
30.44
102.6
5.4
70
8.0
3.2
7.4
29.26
20.92
1.88
35.69
15.5
99
3.1
0.3
0.7
37.43
2.05
30.44
102.6
5.4
70
4.0
0.3
0.6
25.45
18.90
2.38
33.57
10.7
117
2.0
0.2
0.5
37.43
2.05
30.44
102.6
5.4
70
6.0
1.6
3.7
26.62
19.52
2.21
34.18
12.0
111
2.0
0.2
0.5
37.43
2.05
30.44
102.6
5.4
70
8.0
3.0
6.9
27.22
19.83
2.14
34.51
12.8
109
2.0
0.2
0.5
37.43
2.05
30.44
102.6
5.4
70
4.0
0.2
0.5
23.44
17.89
2.71
32.69
8.6
126
1.5
0.1
0.2
37.43
2.05
30.44
102.6
5.4
70
6.0
1.6
3.7
24.54
18.43
2.52
33.14
9.7
121
1.5
0.1
0.2
37.43
2.05
30.44
102.6
5.4
70
8.0
2.9
6.7
25.11
18.73
2.43
33.41
10.3
118
1.5
0.1
0.2
37.43
2.05
30.44
102.6
5.4
70
4.0
0.2
0.4
21.61
17.07
3.11
32.21
7.0
136
1.2
0.1
0.2
37.43
2.05
30.44
102.6
5.4
70
6.0
1.0
2.3
22.56
17.48
2.88
32.41
7.8
131
1.2
0.1
0.2
37.43
2.05
30.44
102.6
5.4
70
8.0
2.8
6.6
23.08
17.72
2.78
32.56
8.3
128
1.2
0.1
0.2
37.43
2.05
30.44
102.6
5.4
70
20
30
40
50
60
70
80
90
100
110
120
Heating - EAT 70ВєF
GPM
HC
kW
HE
LAT
COP
LWT
Interpolation is permissible; extrapolation is not.
All entering air conditions are 80В°F DB and 67В°F WB in cooling, and 70В°F DB in heating.
AHRI/ISO certified conditions are 80.6В°F DB and 66.2В°F WB in cooling and 68В°F DB in heating.
Table does not reflect fan or pump power corrections for AHRI/ISO conditions.
All performance is based upon the lower voltage of dual voltage rated units.
Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated.
Operation below 40В°F EWT is based upon a 15% methanol antifreeze solution.
Operation below 60В°F EWT requires optional insulated water/refrigerant circuit.
See performance correction tables for operating conditions other than those listed above.
See Performance Data Selection Notes for operation in the shaded areas.
Water Pressure drop adder for modulating pump option see table on page 37.
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 34
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Performance Data – TSL36 with Modulating Valve or Variable Speed Pump
1200 CFM Nominal Airflow Heating, 1200 CFM Nominal Airflow Cooling
EWT
В°F
WPD
Cooling - EAT 80/67В°F
WPD
GPM
PSI
FT
TC
SC
kW
HR
EER
LWT
PSI
FT
3.4
0.9
2.0
45.94
30.11
1.63
51.51
28.2
60
9.0
8.6
19.9
23.28
2.22
15.72
85.9
3.1
17
4.5
2.8
6.5
26.08
2.26
18.36
88.1
3.4
22
3.4
0.9
2.0
45.94
30.11
1.63
51.51
28.2
60
6.0
3.4
0.9
2.0
45.94
30.11
1.63
51.51
28.2
60
9.0
3.8
8.8
27.35
2.28
19.56
89.1
3.5
23
7.4
17.1
28.06
2.29
20.23
89.6
3.6
5.2
2.2
5.1
45.94
30.11
1.63
51.51
28.2
60
26
4.5
1.8
4.2
30.51
2.33
22.56
91.5
3.8
30
5.2
2.2
5.1
45.94
30.11
1.63
51.51
28.2
5.2
2.2
5.1
45.94
30.11
1.63
51.51
28.2
60
6.0
2.6
6.0
32.12
2.36
24.08
92.7
4.0
32
60
9.0
7.0
16.2
33.01
2.37
24.92
93.4
4.1
4.5
0.9
2.1
44.37
29.84
1.86
50.71
34
23.9
73
4.5
0.9
2.1
35.03
2.40
26.83
95.0
4.3
28
6.0
2.4
5.6
45.14
30.09
1.75
51.12
25.7
67
6.0
2.4
5.5
36.94
2.43
28.65
96.4
4.5
40
9.0
4.7
10.7 45.79
30.13
4.5
0.9
2.0
42.74
29.04
1.66
51.44
27.6
61
9.0
4.7
10.9
38.00
2.45
29.65
97.3
4.5
43
2.07
49.80
20.7
82
4.5
0.9
2.1
39.39
2.46
31.00
98.3
4.7
6.0
2.3
5.3
43.69
46
29.54
1.95
50.33
22.4
77
6.0
2.3
5.3
40.98
2.48
32.50
99.5
4.8
9.0
4.4
49
10.3 44.55
29.91
1.83
50.81
24.3
71
9.0
4.4
10.2
42.71
2.51
34.13
100.9
5.0
52
4.5
6.0
0.8
1.8
40.81
27.89
2.32
48.73
17.6
92
4.5
0.8
1.8
43.76
2.53
35.11
101.7
5.1
54
2.2
5.1
41.90
28.55
2.18
49.33
19.2
86
6.0
2.2
5.1
45.51
2.57
36.75
103.0
5.2
58
9.0
4.3
10.0 42.94
29.14
2.04
49.91
21.0
81
9.0
4.3
9.9
47.40
2.61
38.50
104.5
5.3
61
4.5
0.8
1.8
38.61
26.55
2.62
47.57
14.7
101
4.5
0.8
1.8
48.00
2.62
39.06
105.0
5.4
63
6.0
2.1
4.9
39.82
27.29
2.46
48.20
16.2
96
6.0
2.1
4.9
49.87
2.67
40.78
106.4
5.5
66
9.0
4.2
9.6
40.98
28.00
2.30
48.83
17.8
91
8.5
4.1
9.5
51.61
2.71
42.36
107.7
5.6
70
4.5
0.8
1.8
36.19
25.14
2.99
46.39
12.1
111
4.3
0.7
1.6
51.61
2.71
42.36
107.7
5.6
70
6.0
2.1
4.9
37.48
25.88
2.79
47.00
13.4
106
4.3
0.7
1.6
51.61
2.71
42.36
107.7
5.6
70
9.0
4.0
9.3
38.75
26.64
2.61
47.64
14.9
101
4.3
0.7
1.6
51.61
2.71
42.36
107.7
5.6
70
4.5
0.7
1.7
33.58
23.73
3.43
45.27
9.8
120
2.8
0.4
0.9
51.61
2.71
42.36
107.7
5.6
70
6.0
2.1
4.8
34.93
24.44
3.19
45.83
10.9
115
2.8
0.4
0.9
51.61
2.71
42.36
107.7
5.6
70
9.0
3.9
9.1
36.27
25.18
2.98
46.43
12.2
110
2.8
0.4
0.9
51.61
2.71
42.36
107.7
5.6
70
4.5
0.7
1.5
30.81
22.39
3.95
44.28
7.8
130
2.1
0.2
0.5
51.61
2.71
42.36
107.7
5.6
70
6.0
2.0
4.6
32.20
23.05
3.68
44.75
8.8
125
2.1
0.2
0.5
51.61
2.71
42.36
107.7
5.6
70
9.0
3.9
8.9
33.59
23.74
3.42
45.28
9.8
120
2.1
0.2
0.5
51.61
2.71
42.36
107.7
5.6
70
4.5
0.6
1.5
27.91
21.16
4.57
43.50
6.1
139
1.7
0.1
0.2
51.61
2.71
42.36
107.7
5.6
70
6.0
1.9
4.4
29.34
21.75
4.25
43.85
6.9
135
1.7
0.1
0.2
51.61
2.71
42.36
107.7
5.6
70
9.0
3.6
8.4
30.76
22.37
3.96
44.27
7.8
130
1.7
0.1
0.2
51.61
2.71
42.36
107.7
5.6
70
20
30
40
50
60
70
80
90
100
110
120
Heating - EAT 70ВєF
GPM
HC
kW
HE
LAT
COP
LWT
Interpolation is permissible; extrapolation is not.
All entering air conditions are 80В°F DB and 67В°F WB in cooling, and 70В°F DB in heating.
AHRI/ISO certified conditions are 80.6В°F DB and 66.2В°F WB in cooling and 68В°F DB in heating.
Table does not reflect fan or pump power corrections for AHRI/ISO conditions.
All performance is based upon the lower voltage of dual voltage rated units.
Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated.
Operation below 40В°F EWT is based upon a 15% methanol antifreeze solution.
Operation below 60В°F EWT requires optional insulated water/refrigerant circuit.
See performance correction tables for operating conditions other than those listed above.
See Performance Data Selection Notes for operation in the shaded areas.
Water Pressure drop adder for modulating pump option see table on page 37.
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 35
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Performance Data Correction Tables
Air Flow Correction Table
Airflow
Cooling
% of
Nominal
(Rated)
SCFM
Total
Capacity
70
75
Heating
Sensible
Capacity
Power
Heat of
Rejection
Heating
Capacity
Power
Heat of
Extraction
0.921
0.8
0.969
0.943
0.942
1.077
0.934
0.934
0.833
0.974
0.952
0.952
1.062
0.947
80
0.946
0.866
0.979
0.961
0.961
1.048
0.958
85
0.958
0.899
0.985
0.97
0.971
1.035
0.969
90
0.971
0.932
0.99
0.979
0.980
1.023
0.979
95
0.985
0.966
0.995
0.989
0.990
1.011
0.989
100
1.000
1.000
1.000
1.000
1.000
1.000
1.000
105
1.017
1.035
1.005
1.013
1.010
0.989
1.011
Entering Air Correction Table
Cooling
Heating
45
1.107
0.768
1.181
Ent.
Air
WB
ВєF
50
1.085
0.814
1.143
45
0.557
*
*
*
*
*
*
*
*
0.986
0.672
55
1.064
0.860
1.108
50
0.658
1.100
*
*
*
*
*
*
*
0.989
0.747
60
1.043
0.906
1.072
55
0.758
0.861
1.091
*
*
*
*
*
*
0.992
0.821
65
1.022
0.952
1.036
60
0.859
0.623
0.854
1.091
1.325
1.383
*
*
*
0.996
0.896
68
1.009
0.981
1.015
65
0.960
*
0.617
0.857
1.093
1.151
1.326
*
*
0.999
0.970
0.984
*
0.561
0.801
1.037
1.095
1.270
1.521
*
1.000
0.988
Entering
Air DBВ°F
Heating
Capacity
Power
Heat of
Extraction
Sensible Capacity-Entering Air Dry Bulb, В°F
Total
Capacity
Power
65
70
75
80
80.6
85
90
95
Heat of
Rejection
70
1.000
1.000
1.000
66.2
75
0.982
1.050
0.962
67
1.000
*
0.523
0.763
1.000
1.058
1.232
1.482
*
1.000
1.000
80
0.953
1.103
0.921
70
1.060
*
*
0.623
0.861
0.919
1.090
1.339
1.563
1.002
1.045
75
1.161
*
*
*
0.629
0.686
0.854
1.101
1.318
1.005
1.119
* = Sensible capacity equals total capacity
AHRI/ISO/ASHRAE 13256-1 uses entering air conditions of Cooling - 80.6В°F DB/66.2В°F WB,
and Heating - 68В°F DB/59В°F WB entering air temperature
Antifreeze Correction Table
Antifreeze Type
Water
Propylene Glycol
Methanol
Ethanol
Ethylene Glycol
Antifreeze
%
Cooling
Heating
EWT 90В°F
EWT 30В°F
WPD
Corr. Fct.
EWT 30В°F
Total
Cap
Sens
Cap
Power
Htg
Cap
Power
0
1.000
1.000
1.000
1.000
1.000
1.000
5
0.995
0.995
1.003
0.989
0.997
1.070
15
0.986
0.986
1.009
0.968
0.990
1.210
25
0.978
0.978
1.014
0.947
0.983
1.360
5
0.997
0.997
1.002
0.989
0.997
1.070
15
0.990
0.990
1.007
0.968
0.990
1.160
25
0.982
0.982
1.012
0.949
0.984
1.220
5
0.998
0.998
1.002
0.981
0.994
1.140
15
0.994
0.994
1.005
0.944
0.983
1.300
25
0.986
0.986
1.009
0.917
0.974
1.360
5
0.998
0.998
1.002
0.993
0.998
1.040
15
0.994
0.994
1.004
0.980
0.994
1.120
25
0.988
0.988
1.008
0.966
0.990
1.200
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 36
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
vFlowв„ў - Modulating Valve and Variable Pump Tables
Modulating Valve for Closed Loop Applications/Water Pressure Drop Adder
Model
026
038
049
064
072
CV
MOPD
4.7
4.7
4.7
7.4
7.4
7.4
10
10
10
19
19
19
19
19
19
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
WPD Adders
GPM
PSI
FT
3
4.5
6
4.5
6.8
9
6
9
12
7.5
11.3
15
8.5
12.8
17
0.41
0.92
1.63
0.37
0.84
1.48
0.36
0.81
1.44
0.16
0.35
0.62
0.20
0.45
0.80
0.94
2.12
3.76
0.85
1.95
3.42
0.83
1.87
3.33
0.36
0.82
1.44
0.46
1.05
1.85
UPM Geo 25-85 Standard Head Variable Pump Performance
35
30
Head (Ft.)
25
20
15
10
5
0
0
5
10
15
Flow (GPM)
20
25
GPM
Head (ft)
0.00
28.7
1.00
28.4
2.00
28.1
3.00
27.9
4.00
27.7
5.00
27.0
6.00
25.3
7.00
23.7
8.00
22.2
9.00
20.6
10.00
19.1
11.00
17.7
12.00
16.2
13.00
14.8
14.00
13.4
15.00
12.1
16.00
10.8
17.00
9.5
18.00
8.2
19.00
7.0
20.00
5.8
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 37
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
PSC Blower Performance Data
TSL with PSC Motor
Airflow in CFM with wet coil and clean 1" (25mm) fiberglass air filter.
Size
Fan
Speed
Rated
CFM
Min
CFM
External Static Pressure (in. wg)
0.10
0.15
0.20
0.25
0.30
0.35
0.55
0.6
0.65
0.70
400
384
368
361
345
329
303
High
09
Medium
400H/350C
Medium
500H/400C
310
Low
Medium
600
447
372
361
502
486
470
451
435
416
400
384
495
480
472
460
447
433
420
405
389
375
361
342
329
402
395
389
380
372
361
350
338
328
318
712
691
668
656
635
623
608
696
675
659
637
623
607
586
350
416
Operation not recommended
24
700
480
328
314
637
600
575
549
524
500
458
712
691
668
656
635
623
608
585
696
675
659
637
623
607
586
490
485
Low
700
674
637
600
575
549
524
500
1204
1184
1163
1134
1104
1072
1040
1001
961
918
875
970
960
945
930
910
890
865
840
810
775
740
Medium
850
596
Low
36
339
High
980
975
890
880
High
30
586
460
380
Low
Medium
0.80
389
High
18
0.75
395
High
15
0.50
402
High
12
0.45
486
451
435
416
Operation not recommended
433
420
400
389
375
284
Low
0.40
Medium
1000
798
980
975
870
865
850
838
825
805
785
768
750
710
670
1204
1184
1163
1134
1100
1072
1040
1001
961
918
875
970
960
945
930
910
890
865
840
810
Low
890
880
870
865
850
840
825
805
High
1436
1405
1379
1345
1316
1280
1235
1205
1166
1120
1081
1040
1000
1200
1180
1168
1145
1126
1098
1070
1040
1014
980
950
910
875
930
920
910
900
890
870
850
Medium
1200
Low
850
950
940
Units with CXM or DXM2 factory shipped on medium and HIGH TAPs. Field select other TAPs if needed.
All airflow is rated at lowest Voltage if unit is dual Voltage rated, i.e. 208V for 208-230V units.
All units AHRI/ISO/ASHRAE 13256-1 rated at CFM in table.
CFM Tolerance is 7%.
TSL with Low Static PSC
Airflow in CFM with wet coil and clean 1" (25mm) fiberglass air filter.
Size
Fan
Speed
Rated CFM
Min.
CFM
High
09
Medium
400H/350C
284
Low
High
12
Medium
500H/400C
310
Low
High
15
Medium
600
416
Low
High
18
Medium
700
480
Low
High
24
30
36
Medium
850
596
External Static Pressure (in. wg)
0.10
0.15
0.20
Operation not recommended
420
400
375
340
320
300
330
310
290
375
420
400
340
320
330
310
0.25
0.30
0.35
0.40
330
310
300
290
330
310
Operation not recommended
748
726
703
688
672
659
625
594
584
580
571
561
551
541
526
521
516
505
500
489
468
461
451
726
703
688
672
659
625
615
615
584
580
571
561
551
541
526
511
516
505
500
489
1220
1200
1190
1180
1150
1135
1120
1100
950
940
930
920
900
885
870
Low
840
835
830
820
810
795
787
1220
1200
1190
1180
1150
1135
1120
950
940
930
920
900
885
870
1000
798
Low
840
835
830
820
810
798
High
1200
1190
1180
1150
1135
1120
1100
940
930
920
900
880
870
860
Medium
1200
850
0.50
285
High
Medium
0.45
511
1100
Low
Units with CXM or DXM2 factory shipped on medium and HIGH TAPs. Field select other TAPs if needed.
All airflow is rated at lowest Voltage if unit is dual Voltage rated, i.e. 208V for 208-230V units.
All units AHRI/ISO/ASHRAE 13256-1 rated at CFM in table.
CFM Tolerance is 7%.
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 38
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
ECM Blower Performance Data
TSL Ducted ECM 65" Cabinet
All data wet coil clean filter.
Tranquility
Model
ESP
Range
(in wg)
Constant
Cooling Mode
TSL12
TSL15
TSL18
TSL24
TSL30
TSL36
0.05 – 0.4
0.05 – 0.4
0.1 – 0.5
0.1 – 0.5
0.15 – 0.6
0.15 – 0.6
0.15 – 0.6
Heating Mode
Stg 2
Stg 1
Stg 2
Stg 1
Stg 2
Stg 1
Fan Only
Mode
400
350
350
300
450
400
300
Setting
Default
TSL09
Dehumid Mode
Hi Fan
Mode
Aux
Emerg
Mode
400
450
Maximum
450
450
450
450
450
450
450
450
450
Minimum
350
300
350
300
400
300
300
350
400
Default
450
400
400
350
450
400
300
400
450
Maximum
450
450
450
450
450
450
450
450
450
Minimum
400
350
350
300
400
350
300
350
400
Default
700
600
600
500
600
500
400
600
600
Maximum
700
700
700
600
700
700
700
700
700
Minimum
600
500
500
450
500
450
450
500
500
Default
800
700
700
600
700
600
450
600
700
Maximum
800
800
800
700
800
800
800
800
800
Minimum
700
600
600
500
600
500
450
500
600
Default
850
800
750
650
850
750
500
750
850
Maximum
950
850
950
800
950
850
950
950
950
Minimum
800
650
650
600
750
650
500
650
750
Default
1150
1000
1000
900
1150
1000
600
850
1150
Maximum
1150
1150
1100
1000
1150
1150
1100
1100
1150
Minimum
1000
900
900
800
1000
900
600
800
1000
Default
1200
1100
1100
1000
1200
1100
800
950
1200
Maximum
1350
1200
1200
1100
1350
1200
1200
1350
1350
Minimum
1100
1000
1000
950
1100
1000
800
1000
1100
All units AHRI/ISO/ASHRAE 13256-1 rated on CFM shown on performance data page.
Airflow is rated at lowest Voltage if unit is dual Voltage rated, i.e. 208V for 208-230V units.
Shipped on default settings. C = Cooling; H = Heating; D = Dehumidification.
Change from default setting with service tool (ACDU02) or Communicating thermostat (ATC32U01).
Airflow is controlled within 7% up to the max ESP.
TRM15-36 ramp default is 30.
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 39
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Sound Data - Case Radiated
Standard Construction Free Inlet Case Radiated
Model
TSL09
TSL12
TSL15
TSL18
TSL24
TSL30
TSL36
Mode
UltraQuiet Construction Free Inlet Case Radiated
Octive Band Frequency, Hz
Octive Band Frequency, Hz
125
250
500
1000
2000
4000
8000
125
250
500
1000
2000
4000
8000
Fan Only Low Speed Fan
64
57
54
52
47
44
41
64
57
54
52
47
44
41
Fan Only Med Speed Fan
68
61
57
55
50
48
45
68
61
57
55
50
48
45
Fan Only High Speed Fan
69
63
59
56
52
51
47
69
63
59
56
52
51
47
Cooling Low Speed Fan
71
60
60
57
50
48
47
70
59
60
57
50
48
47
Cooling Med Speed Fan
71
63
60
57
52
50
48
70
62
60
57
52
50
48
Cooling High Speed Fan
72
63
61
58
53
52
50
71
62
61
58
53
52
50
Heating Low Speed Fan
74
62
58
57
53
51
49
73
61
58
57
53
51
49
Heating Med Speed Fan
74
64
59
59
54
52
50
73
63
59
59
54
52
50
Heating High Speed Fan
75
64
60
59
55
53
51
74
63
60
59
55
53
51
Fan Only Low Speed Fan
64
57
55
52
47
44
41
64
57
55
52
47
44
41
Fan Only Med Speed Fan
68
61
57
55
51
49
45
68
61
57
55
51
49
45
Fan Only High Speed Fan
70
63
59
55
52
51
48
70
63
59
55
52
51
48
Cooling Low Speed Fan
69
60
57
52
48
45
42
68
59
57
52
48
45
42
Cooling Med Speed Fan
70
62
58
55
51
49
46
69
61
58
55
51
49
46
Cooling High Speed Fan
71
64
59
56
52
51
48
70
63
59
56
52
51
48
Heating Low Speed Fan
69
59
54
52
47
44
41
68
58
54
52
47
44
41
Heating Med Speed Fan
70
62
57
54
50
48
45
69
61
57
54
50
48
45
Heating High Speed Fan
71
63
58
55
52
51
47
70
62
58
55
52
51
47
Fan Only Low Speed Fan
69
62
61
57
53
52
46
69
62
61
57
53
52
46
Fan Only Med Speed Fan
69
62
62
58
54
52
47
69
62
62
58
54
52
47
Fan Only High Speed Fan
69
63
62
58
54
53
47
69
63
62
58
54
53
47
Cooling Low Speed Fan
69
63
61
57
53
52
47
68
62
61
57
53
52
47
Cooling Med Speed Fan
70
63
62
58
54
53
48
69
62
62
58
54
53
48
Cooling High Speed Fan
70
64
62
58
54
53
48
69
63
62
58
54
53
48
Heating Low Speed Fan
69
63
61
57
53
52
46
68
62
61
57
53
52
46
Heating Med Speed Fan
69
63
61
58
53
52
47
68
62
61
58
53
52
47
Heating High Speed Fan
70
64
62
58
54
53
47
69
63
62
58
54
53
47
Fan Only Low Speed Fan
70
64
61
56
52
50
44
70
64
61
56
52
50
44
Fan Only Med Speed Fan
70
64
61
56
52
50
44
70
64
61
56
52
50
44
Fan Only High Speed Fan
69
63
61
56
51
50
44
69
63
61
56
51
50
44
Cooling Low Speed Fan
71
65
61
59
53
53
58
70
64
61
59
53
53
58
Cooling Med Speed Fan
71
65
61
58
53
53
57
70
64
61
58
53
53
57
Cooling High Speed Fan
70
64
61
58
53
52
56
69
63
61
58
53
52
56
Heating Low Speed Fan
70
65
61
58
53
53
55
69
64
61
58
53
53
55
Heating Med Speed Fan
70
65
61
58
53
53
55
69
64
61
58
53
53
55
Heating High Speed Fan
69
64
61
57
53
53
55
68
63
61
57
53
53
55
Fan Only Low Speed Fan
68
62
59
56
53
51
46
68
62
59
56
53
51
46
Fan Only Med Speed Fan
69
64
60
58
55
54
49
69
64
60
58
55
54
49
Fan Only High Speed Fan
71
70
62
60
58
57
52
71
70
62
60
58
57
52
Cooling Low Speed Fan
68
63
60
56
53
52
47
67
62
60
56
53
52
47
Cooling Med Speed Fan
70
64
60
58
55
54
49
69
63
60
58
55
54
49
Cooling High Speed Fan
72
69
63
61
58
57
53
71
68
63
61
58
57
53
Heating Low Speed Fan
70
62
60
56
53
53
47
69
61
60
56
53
53
47
Heating Med Speed Fan
70
64
61
57
55
54
49
69
63
61
57
55
54
49
Heating High Speed Fan
72
70
62
59
57
57
52
71
69
62
59
57
57
52
Fan Only Low Speed Fan
67
63
59
56
53
52
46
67
63
59
56
53
52
46
Fan Only Med Speed Fan
69
64
60
58
55
54
49
69
64
60
58
55
54
49
Fan Only High Speed Fan
71
70
63
60
58
57
52
71
70
63
60
58
57
52
Cooling Low Speed Fan
71
63
61
59
54
53
50
70
62
61
59
54
53
50
Cooling Med Speed Fan
71
64
62
59
55
54
49
70
63
62
59
55
54
49
Cooling High Speed Fan
73
69
63
62
58
57
53
72
68
63
62
58
57
53
Heating Low Speed Fan
74
63
60
57
53
52
48
73
62
60
57
53
52
48
Heating Med Speed Fan
74
64
61
58
55
54
49
73
63
61
58
55
54
49
Heating High Speed Fan
74
70
63
60
58
57
52
73
68
63
60
58
57
52
Fan Only Low Speed Fan
67
61
58
55
52
50
44
67
61
58
55
52
50
44
Fan Only Med Speed Fan
70
66
61
59
56
55
49
70
66
61
59
56
55
49
Fan Only High Speed Fan
71
67
62
61
58
57
51
71
67
62
61
58
57
51
Cooling Low Speed Fan
71
61
59
57
52
50
45
70
60
59
57
52
50
45
Cooling Med Speed Fan
70
66
62
60
57
55
49
69
65
62
60
57
55
49
Cooling High Speed Fan
73
67
63
62
59
57
52
72
66
63
62
59
57
52
Heating Low Speed Fan
78
62
60
56
53
50
45
77
61
60
56
53
50
45
Heating Med Speed Fan
75
66
61
59
56
55
49
74
65
61
59
56
55
49
Heating High Speed Fan
76
67
62
61
58
57
51
75
66
62
61
58
57
51
Notes: Sound power data is obtained using appropriate testing method in a qualified reverberant sound laboratory as per AHRI 260-2011.
For d'BA and NC in particular room use sound analyzer on climatemaster.com.
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 40
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Sound Data - Ducted Discharge
Standard Construction Ducted Discharge
Model
TSL09
TSL12
TSL15
TSL18
TSL24
TSL30
TSL36
Mode
UltraQuiet Construction Ducted Discharge
Octive Band Frequency, Hz
Octive Band Frequency, Hz
125
250
500
1000
2000
4000
8000
125
250
500
1000
2000
4000
8000
Fan Only Low Speed Fan
59
52
47
51
40
37
37
59
52
47
51
40
37
37
Fan Only Med Speed Fan
62
55
46
52
44
43
39
62
55
46
52
44
43
39
Fan Only High Speed Fan
65
58
49
52
46
45
41
65
58
49
52
46
45
41
Cooling Low Speed Fan
59
52
50
51
40
38
37
58
52
50
51
40
38
37
Cooling Med Speed Fan
63
56
47
52
44
43
40
62
56
47
52
44
43
40
Cooling High Speed Fan
64
58
49
52
47
46
42
63
58
49
52
47
46
42
Heating Low Speed Fan
60
52
44
49
40
37
37
59
52
44
49
40
37
37
Heating Med Speed Fan
63
55
46
52
44
42
39
62
55
46
52
44
42
39
Heating High Speed Fan
65
57
48
52
46
45
41
64
57
48
52
46
45
41
Fan Only Low Speed Fan
59
52
45
49
40
37
37
59
52
45
49
40
37
37
Fan Only Med Speed Fan
63
56
47
53
44
43
39
63
56
47
53
44
43
39
Fan Only High Speed Fan
63
56
47
53
44
43
39
63
56
47
53
44
43
39
Cooling Low Speed Fan
69
60
57
52
48
45
42
68
60
57
52
48
45
42
Cooling Med Speed Fan
70
62
58
55
51
49
46
69
62
58
55
51
49
46
Cooling High Speed Fan
71
64
59
56
52
51
48
70
63
59
56
52
51
48
Heating Low Speed Fan
60
52
44
48
40
37
36
59
52
44
48
40
37
36
Heating Med Speed Fan
63
55
46
52
44
42
39
62
55
46
52
44
42
39
Heating High Speed Fan
65
57
48
53
46
45
41
64
57
48
53
46
45
41
Fan Only Low Speed Fan
68
61
53
52
47
45
40
68
61
53
52
47
45
40
Fan Only Med Speed Fan
68
63
53
52
47
45
39
68
63
53
52
47
45
39
Fan Only High Speed Fan
68
62
52
52
47
45
39
68
62
52
52
47
45
39
Cooling Low Speed Fan
68
63
53
53
48
45
40
67
63
53
53
48
45
40
Cooling Med Speed Fan
68
63
53
53
48
45
40
67
63
53
53
48
45
40
Cooling High Speed Fan
68
62
53
52
47
45
40
67
62
53
52
47
45
40
Heating Low Speed Fan
68
61
52
52
47
44
39
67
61
52
52
47
44
39
Heating Med Speed Fan
68
61
52
52
47
44
39
67
61
52
52
47
44
39
Heating High Speed Fan
69
62
53
52
47
44
39
68
61
53
52
47
44
39
Fan Only Low Speed Fan
68
61
53
52
47
45
40
68
61
53
52
47
45
40
Fan Only Med Speed Fan
68
61
53
53
47
45
40
68
61
53
53
47
45
40
Fan Only High Speed Fan
68
62
52
52
47
45
39
68
62
52
52
47
45
39
Cooling Low Speed Fan
68
61
53
52
47
45
40
67
61
53
52
47
45
40
Cooling Med Speed Fan
67
60
52
52
47
45
40
66
60
52
52
47
45
40
Cooling High Speed Fan
67
60
52
52
47
45
39
66
59
52
52
47
45
39
Heating Low Speed Fan
68
61
52
52
47
44
39
67
61
52
52
47
44
39
Heating Med Speed Fan
68
61
52
52
47
44
39
67
61
52
52
47
44
39
Heating High Speed Fan
68
60
52
52
47
44
39
67
60
52
52
47
44
39
Fan Only Low Speed Fan
64
64
54
53
50
48
42
64
64
54
53
50
48
42
Fan Only Med Speed Fan
66
64
55
53
52
50
44
66
64
55
53
52
50
44
Fan Only High Speed Fan
68
66
57
56
54
53
47
68
66
57
56
54
53
47
Cooling Low Speed Fan
64
63
55
54
50
48
42
63
63
55
54
50
48
42
Cooling Med Speed Fan
65
65
55
53
52
50
44
64
65
55
53
52
50
44
Cooling High Speed Fan
68
66
57
56
55
53
47
67
66
57
56
55
53
47
Heating Low Speed Fan
64
61
54
53
50
47
41
63
61
54
53
50
47
41
Heating Med Speed Fan
65
62
54
53
51
49
43
64
62
54
53
51
49
43
Heating High Speed Fan
67
65
57
55
54
52
46
66
64
57
55
54
52
46
Fan Only Low Speed Fan
64
62
54
53
50
48
42
64
62
54
53
50
48
42
Fan Only Med Speed Fan
65
63
55
53
52
50
43
65
63
55
53
52
50
43
Fan Only High Speed Fan
68
66
57
56
55
53
47
68
66
57
56
55
53
47
Cooling Low Speed Fan
63
62
58
52
50
48
42
62
62
58
52
50
48
42
Cooling Med Speed Fan
65
64
56
53
52
50
43
64
64
56
53
52
50
43
Cooling High Speed Fan
68
65
57
55
55
53
47
67
64
57
55
55
53
47
Heating Low Speed Fan
66
61
53
53
50
47
41
65
61
53
53
50
47
41
Heating Med Speed Fan
67
62
55
54
52
49
43
66
62
55
54
52
49
43
Heating High Speed Fan
68
64
57
55
54
52
46
67
63
57
55
54
52
46
Fan Only Low Speed Fan
64
59
53
50
49
46
40
64
59
53
50
49
46
40
Fan Only Med Speed Fan
67
63
56
54
53
51
45
67
63
56
54
53
51
45
Fan Only High Speed Fan
68
65
58
56
55
53
47
68
65
58
56
55
53
47
Cooling Low Speed Fan
64
58
54
49
48
45
40
63
58
54
49
48
45
40
Cooling Med Speed Fan
67
63
56
54
53
51
45
66
63
56
54
53
51
45
Cooling High Speed Fan
69
65
58
56
55
53
48
68
64
58
56
55
53
48
Heating Low Speed Fan
64
58
52
50
49
45
40
63
58
52
50
49
45
40
Heating Med Speed Fan
67
63
56
54
52
50
44
66
63
56
54
52
50
44
Heating High Speed Fan
68
64
57
56
54
52
46
67
64
57
56
54
52
46
Notes: Sound power data is obtained using appropriate testing method in a qualified reverberant sound laboratory as per AHRI 260-2011.
For d'BA and NC in particular room use sound analyzer on climatemaster.com.
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 41
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Physical Data
Model
09
12
15
Compressor (1 Each)
Factory Charge HFC-410A (oz) [kg]
18
24
Rotary
30
36
Scroll
34 [.07]
34 [.97]
43 [1.22]
53 [1.51]
71 [2.01]
66 [1.87]
84 [2.38]
6.75 x 7.25
[174 x 184]
6.75 x 7.25
[174 x 184]
9.50 x 7.12
[241 x 181]
9.50 x 7.12
[241 x 181]
9.50 x 8.06 [241 x 205]
6.75 x 7.25
[174 x 184]
6.75 x 7.25
[174 x 184]
9.50 x 7.12
[241 x 181]
9.50 x 7.12
[241 x 181]
9.50 x 8.06 [241 x 205]
Air Coil Dimensions (h x w) - (in) [mm]
28 x 14
[711 x 356]
28 x 14
[711 x 356]
28 x 14
[711 x 356]
28 x 14 [711 x 356]
30 x 18
[762 x 457]
30 x 18
[762 x 457]
30 x 18
[762 x 457]
Standard Filter - 1" [25.4 mm],
(w x h) - (in) [mm]
16 x 30
[406 x 762]
16 x 30
[406 x 762]
16 x 30
[406 x 762]
16 x 30
[406 x 762]
20 x 32
[508 x 813]
20 x 32
[508 x 813]
20 x 32
[508 x 813]
Coax Volume (Gallons)
0.215
0.26
0.367
0.367
0.602
0.602
0.602
1/2
1/2
3/4
3/4
103 [47]
105 [48]
123 [56]
125 [57]
PSC Blower Wheel
Blower Wheel Size (dia x w) (in) [mm]
ECM Blower Wheel
Blower Wheel Size (dia x w) (in) [mm]
Chassis Air Coil
Hose Size (in)
1
Weight
Chassis - (lbs) [kg]
Cabinet - (lbs) [kg]
108 [49]
186 [84]
190 [86]
192 [87]
142 [64]
Unit Maximum Water Working Pressure
Options
Base Unit (Hoses)
Internal Secondary Pump (ISP)
Max Pressure PSIG [kPa]
400 [2,757]
145 [999]
Internal Motorized Water Valve (WMV)*
300 [2,068]
Internal Auto Flow Valve
400 [2,757]
Use the lowest maximum pressure rating when multiple options are combined.
* Units with MWV have 300 [2068] High Pressure Water switch - 250 [1723] Auto Reset
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 42
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Electrical Data - PSC Motor
Rated
Voltage
Model #
Min/
Max
Voltage
Compressor
Fan
Motor
Standard Unit
With Pump
SCCR
SCCR
SCCR
SCCR
Total
FLA
MCA
kA rms
Symetrical
Volts
Maximum
Max
Fuse
Amps
Total
FLA
MCA
kA rms
Symetrical
Volts
Maximum
Max
Fuse /
HACR
15
RLA
LRA
FLA
TSL09G 208-230/60/1 197/254
3.7
22
0.8
4.5
5.5
NA
NA
15
5.0
6.0
NA
NA
265/60/1
239/292
3.5
22
0.8
4.3
5.2
NA
NA
15
4.8
5.7
NA
NA
15
TSL12G 208-230/60/1 197/254
4.7
25
0.8
5.5
6.7
NA
NA
15
6.0
7.2
NA
NA
15
265/60/1
239/292
4.2
22
0.8
5
6.1
NA
NA
15
5.5
6.6
NA
NA
15
TSL15G 208-230/60/1 197/254
5.6
29
2.2
7.8
9.2
NA
NA
15
8.6
10.0
NA
NA
15
265/60/1
5
28
1.7
6.7
8.0
NA
NA
15
7.5
8.8
NA
NA
15
6.6
33
2.2
8.8
10.5
NA
NA
15
9.6
11.3
NA
NA
20
TSL09E
TSL12E
TSL15E
239/292
TSL18G 208-230/60/1 197/254
239/292
5.6
28
1.7
7.3
8.7
NA
NA
15
8.1
9.5
NA
NA
15
TSL24G 208-230/60/1 197/254
265/60/1
12.8
58.3
2.6
15.4
18.6
NA
NA
30
16.2
19.4
NA
NA
30
265/60/1
239/292
9.6
54
2.0
11.6
14.0
NA
NA
25
12.4
14.8
NA
NA
25
TSL30G 208-230/60/1 197/254
12.8
64
2.6
15.4
18.6
NA
NA
30
16.2
19.4
NA
NA
30
265/60/1
239/292
10.9
60
2.0
12.9
15.6
NA
NA
25
13.7
16.4
NA
NA
25
TSL36G 208-230/60/1 197/254
14.1
77
2.7
16.8
20.3
NA
NA
35
17.6
21.1
NA
NA
35
265/60/1
12.2
72
2.9
15.1
18.2
NA
NA
30
15.9
19.0
NA
NA
30
SCCR
SCCR
TSL18E
TSL24E
TSL30E
TSL36E
239/292
TSL with Low Static PSC
Rated
Voltage
Model #
TSL09G
208-230/60/1 197/254
FLA
MCA
kA rms
symetrical
Volts
Maximum
Max
Fuse
Amps
Total
FLA
MCA
kA rms
symetrical
Volts
Maximum
Max
Fuse /
HACR
15
0.4
4.1
5.0
NA
NA
15
4.6
5.5
NA
NA
0.3
3.8
4.7
NA
NA
15
4.3
5.2
NA
NA
15
208-230/60/1 197/254
4.7
25
0.4
5.1
6.3
NA
NA
15
5.6
6.8
NA
NA
15
239/292
4.2
22
0.3
4.5
5.6
NA
NA
15
5
6.1
NA
NA
15
208-230/60/1 197/254
265/60/1
5.6
29
1
6.6
8.0
NA
NA
15
7.4
8.8
NA
NA
15
5
28
0.9
5.9
7.2
NA
NA
15
6.7
8.0
NA
NA
15
15
265/60/1
239/292
208-230/60/1 197/254
6.6
33
1
7.6
9.3
NA
NA
15
8.4
10.1
NA
NA
239/292
5.6
28
0.9
6.5
7.9
NA
NA
15
7.3
8.7
NA
NA
15
208-230/60/1 197/254
12.8
58.3
2.6
15.4
18.6
NA
NA
30
16.2
19.4
NA
NA
30
265/60/1
239/292
9.6
54
2
11.6
14.0
NA
NA
25
12.4
14.8
NA
NA
25
208-230/60/1 197/254
265/60/1
12.8
64
2.6
15.4
18.6
NA
NA
30
16.2
19.4
NA
NA
30
239/292
10.9
60
2
12.9
15.6
NA
NA
25
13.7
16.4
NA
NA
25
208-230/60/1 197/254
265/60/1
14.1
77
2.6
16.7
20.2
NA
NA
35
17.5
21.0
NA
NA
35
12.2
72
2
14.2
17.3
NA
NA
30
15.0
18.1
NA
NA
30
TSL30E
TSL36G
LRA
SCCR
22
TSL24E
TSL30G
RLA
Total
FLA
With Pump
SCCR
22
TSL18E
TSL24G
Standard Unit
3.5
TSL15E
TSL18G
Fan
Motor
3.7
TSL12E
TSL15G
Compressor
239/292
265/60/1
TSL09E
TSL12G
Min/
Max
Voltage
TSL36E
265/60/1
239/292
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 43
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Electrical Data - ECM Motor
Model
with
ECM
Motor
Rated
Voltage
Min/
Max
Voltage
Standard Unit
Compressor
Motor
FLA
RLA
LRA
With Pump
SCCR
SCCR
Total
FLA
MCA
kA rms
Symetrical
Volts
Maximum
Max
Total
Fuse /
FLA
HACR
SCCR
SCCR
MCA
kA rms
Symetrical
Volts
Maximum
Max
Fuse /
HACR
TSL09G 208-230/60/1 197/254
3.7
22
2.6
6.3
7.2
NA
NA
15
6.8
7.7
NA
NA
15
265/60/1
239/292
3.5
22
2.5
6
6.9
NA
NA
15
6.8
7.7
NA
NA
15
TSL12G 208-230/60/1 197/254
4.7
25
2.6
7.2
8.5
NA
NA
15
7.8
8.5
NA
NA
15
265265/60/1
239/292
4.2
22
2.5
6.7
7.8
NA
NA
15
7.5
8.6
NA
NA
15
TSL15G 208-230/60/1 197/254
5.6
29
2.6
8.2
9.6
NA
NA
15
9
10.4
NA
NA
15
5
28
2.1
7.1
8.4
NA
NA
15
7.9
9.2
NA
NA
15
6.6
33
2.6
9.2
10.9
NA
NA
15
10
11.7
NA
NA
15
TSL09E
TSL12E
TSL15E
265/60/1
239/292
TSL18G 208-230/60/1 197/254
239/292
5.6
28
2.1
7.7
9.1
NA
NA
15
8.5
9.9
NA
NA
15
TSL24G 208-230/60/1 197/254
12.8
58.3
2.6
15.4
18.6
NA
NA
30
16.2
19.4
NA
NA
30
TSL18E
265/60/1
239/292
9.6
54
2.1
11.7
14.1
NA
NA
20
12.5
14.9
NA
NA
25
TSL30G 208-230/60/1 197/254
12.8
64
3.9
16.7
19.9
NA
NA
30
17.5
20.7
NA
NA
30
265/60/1
TSL24E
265/60/1
239/292
10.9
60
3.2
14.1
16.8
NA
NA
25
14.9
17.6
NA
NA
25
TSL36G 208-230/60/1 197/254
14.1
77
5.2
19.3
22.8
NA
NA
35
20.1
23.6
NA
NA
35
265/60/1
12.2
72
4.7
16.9
20.0
NA
NA
30
17.7
20.8
NA
NA
30
TSL30E
TSL36E
239/292
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 44
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
TSL Series Wiring Diagram Matrix
All current diagrams can be located online at climatemaster.com. Click �Commercial’ (go to �Quick Links’
in the upper right) using the part numbers presented below.
Model
Refrigerant
TSL09-36
PSC
TSL09-12
ECM Motor
TSL15-36
ECM Motor
EarthPure
(HFC-410A)
В®
Wiring Diagram
Part Number
96B0173N33
96B0173N32
96B0173N34
Electrical
208-230/60/1,
265/60/1
Control
Agency
CXM
DXM2
ACO/MCO
ETL
DXM2
96B0173N35
MPC Connections
NOTE 2
EH2
HOT/R
Notes:
1. Refer to wire diagram for connection to CXM/DXM2. Low voltage wiring
must be class 1 and voltage rated equal or greater than unit supply voltage.
2. ASW06 - ASW08 MOVE JUMPER TO LSTAT, ASW09 - ASW11
MOVE JUMPER TO RNET.
CABINET
CHASSIS
NOTE 1
LON Connections
Note:
1. Refer to wire diagram for connection to CXM/DXM2. Low
voltage wiring must be class 1 and voltage rated equal or
greater than unit supply voltage.
CABINET
CHASSIS
NOTE 1
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 45
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Typical Wiring Diagram – TSL09 - 36 CXM with PSC Motor
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 46
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Typical Wiring Diagram – TSL09 - 36 DXM2 with PSC Motor
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 47
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Typical Wiring Diagram – TSL09 - 12 DXM2 with ECM Motor
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 48
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Typical Wiring Diagram – TSL15 - 36 DXM2 with ECM Motor
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 49
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Typical Wiring Diagram – Single Phase TSL Units with DXM2 Controller with Night Setback,
Emergency Shutdown, & Pump Restart
DXM 2
DXM 2
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 50
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Typical Unit - Exploded View
Major Components
1. TSL Cabinet (Furred-in)
A - floating condensate drain pan
B - drain P trap
C - optional disconnect / breaker location
D - upper control box (high voltage terminal blocks optional MPC, Lon)
E - blower assembly/motor
F - shutoffs (not shown)
G - filter panel
H - filter
2. TSL Chassis
A - compressor acoustic enclosure, compressor, water coil, reversing valve
B - data plate
C - lower control box (transformer, CXM/DXM2, contactor)
D - capacitor
E - high and low voltage locking quick connectors
F - air coil
3. Architectural Acoustic Return Air Panel (G)
A - frame
B - hinged inner panel
4. Hoses (Not Shown)
5. Thermostat (Not Shown)
6. Supply Air Ductwork, field supplied (Not shown)
1C
1E
1D
2F
1G
2E
3A
1H
3B
1A
1
1B
2A
2
2B
2D
2C
3
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 51
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
TSL – Standard Unit, Risers Ship Separate
Top Supply
Air Opening
Remote
T/Stat
Entrance
Power
Entrance
2.00(51)
Service
Area
Note 3
24
(610)
Upper Control Box & Electrical
Power Connections
Motor-Blower Assembly
Filter Panel (Not Shown)
Flex Hose
Filter, Throwaway
Air coil
Shutoff (On Riser)
Return Air Opening
Heat Pump Chassis
Optional motorized water
valve, pump, or auto flow
regulator valve
Trapped
Condensate Drain Hose
(Note 4)
Lower Drain Pan
Front
Notes:
1. All dimensions are in inches (mm).
2. The return air/control box side is defined as front of cabinet. Riser K.O.'s are on all
panels.
3. Service area from finished wall.
4. Installer must cut drain hose connect to condensate pan and riser stubout, clamp
both ends.
5. Contractor to supply ductwork, see blower table for maximum static.
When cabinets are pushed up to risers allow suffient clearance.
Shutoffs should be inside cabinet.
1/4” to 1”
(6 to 25)
Approx.
6”
(152)
Shutoffs
Inside
Push
Push
Push
Step 1
Risers Opposite
Return Air Opening
Step 1
Risers Adjacent to
Return Air Opening
Step 2
Final
Cabinet Postion
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 52
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Cabinet Dimensions
C
E
F
.75 (19)
DIA 2 Holes
High Voltage
Entrance
D
Low Voltage
Entrance
4.75 [120]
1.50 [38]
1.50 [38]
1.25
[32]
5.00
[127]
65.00
[1651]
5.00
[127]
2.75
[70]
OPENING
FOR
CHASSIS
2.50 x 12.00 K.O.
[64 x 305]
2.88
[73]
57.00
[1259]
2.88
[73]
5.00
(127)
35.75
[908]
Note 4
12.12
[308]
12.00
[305]
12.12
[308]
6.00
[152]
L.H. SIDE
A
B
FRONT
R.H. SIDE
12.12
[308]
2.25 x 3.00 K.O.
[57 x 76]
BACK
(24-36)
3.12 [79]
BACK
(09-18)
Notes:
1. All dimensions are in inches (mm).
2. Cabinets have riser K.O.'s, all panels. Remove only K.O.'s necessary to configure
cabinet. Seal any K.O.'s removed by mistake.
3. Service area to be width of cabinet and 24" [610] from finished wall.
4. For 09-18 cabinet use drain on opposite side from supply and return risers.
Unit Size
TSL09 - 12
A
B
C
D
19.25 [489]
19.00 [483]
11.50 [292]
6.00 [152]
24.25 [616]
24.00 [610]
12.00 [305]
12.00 [305]
TSL15 - 18
TSL24 - 36
E
2.62 [66.5]
3.87 [93]
6.12 [155.5]
F
.665 [17]
1.04 [26]
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 53
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Cabinet Slot Dimensions and Riser Arrangements
1/4” - 1”
(6-25)
TOP VIEWS
2.75”
(70)
12.00”
(305)
A
S
S
5.00”
(127)
R
9.25”
(235)
2.75”
(70)
STYLE
4 RA
R
B
D
D
STYLE
4
Risers Left
Side
STYLE
5
Risers Right
Side
RA
SIDE
RA
SIDE
Model
09-18
24-36
A
STYLE
5 RA
STYLE
3 RA
STYLE
2 RA
STYLE
2 RA
STYLE
3 RA
B
19.25 [489]
24.25 [616]
STYLE
4 RA
STYLE
5 RA
19 [483]
24 [610]
Note 8
2.88”
(73)
D
R
2.88”
(73)
S
S
STYLE
2 RA
R
D
STYLE
3 RA
STYLE
5 RA
STYLE
4 RA
STYLE
4 RA
STYLE
5 RA
9.25”
(235)
12.12”
(308)
STYLE
3
Risers Back
Right
STYLE
2
Risers Back
Left
RA
SIDE
RA
SIDE
STYLE
2 RA
STYLE
3 RA
Note 8
NOTICE! Not all styles will stack above
or adjacent to each other. (See Note 8).
FRONT VIEW
STYLE 3
Notes:
2.88”
(73)
1.
2.
3.
4.
5.
6.
7.
5.00”
(127)
12.00”
[305]
2.50”
(64)
12.12”
(308)
NOTICE!
39.75”
[1100]
35.75”
Note
7
[908]
2.25”
(57)
3.00”
(76)
Dimensions are inches [mm].
Style refers to cabinet model digit 9 - riser location.
Return air side is the front of the cabinet.
Supply riser is closest to corner.
Drain is not centered on D1-D4 (09-18) cabinets.
Slots allow for riser stack expansion and contraction.
Supply and return riser stub outs are 39.75" (1100) from
bottom of cabinet and is not centered vertically in slot. Drain
Runout is 3.12" (79) from bottom of cabinet.
8. From floor to floor on one riser stack you can only have; all
same style, styles 2 and 5; or styles 3 and 4. For master/slave
units you can only have styles 3 or 4 adjacent to 2 or 5.
9. Risers ship separate. Secure riser stack to building structure.
10. Riser shutoff should be inside cabinet.
3.125” (all sizes)
(79)
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 54
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Typical Cabinet Installation - Flush
NOTICE!
C
Seal between studs and cabinet flanges
with weather tight foam material to
prevent wall cavity air from infiltrating unit
or room.
R.O.
A
High Voltage
TSL CABINET
FOR REMOTE
MOUNTED
THERMOSTAT
TOP VIEW
X X
X
Note 4
OUTSIDE
CORNER
C
2x4
nominal
studs
B
FRONT
VIEW
X
Low Voltage Conduit
57 1/2
(1460)
X
1 Layer
seal gap
(4) sides
1-1/4” (32) min - Note 7
to 2 3/8” (60) max from cabinet
to front of finished wall
5/8” (16) drywall 1
or 2 layers. Position
studs accordingly.
Floor
5 7/8
(149)
Note 6
X
X X
Drywall Opening
Note
4
Cabinet Flange
(4) sides
INSIDE
CORNER
1.25 (32)
Model
A
B
C
09-18
24-36
19.25
[489]
24.25
[610]
19
[483]
24
[610]
19.5
[495]
24.5
[622]
1.
2.
3.
4.
5.
6.
7.
All dimensions are in inches (mm).
Cabinet configuration will determine slab core
drilling location and walls surrounding cabinet.
Recommend stud walls surrounding cabinet.
Drywall and studs should not be attached or
contacting cabinet for best sound attenuation.
Where possible fill gaps with sound absorbing
material. Use iso pad under cabinet. Secure
cabinet to floor in two places at back.
Return air panel (not shown) overlaps rough
opening, allow minimum of 3 1/2" (89) dry wall
to corner. Do not caulk G panel to wall.
Installer supplied top duct should connect with
flex boot.
If cabinet stand or ISO pad is used add to
dimension.
For 2"(50) filter set cabinet 2"(50) minimum
from front of drywall.
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 55
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Typical Cabinet Installation - Recessed
X
6.00
(152)
Note 8
СҐ NOTICE! СҐ
Recessed cabinet requires frame kit.
Seal Gap (4) Sides
Frame
Outside
Drywall
Outside air requires motorized damper.
X
G Style
Return Air Panel
Seal between the frame and cabinet with
weather seal material to avoid air being pulled
in from the wall cavity. Attach frame to studs
not cabinet.
B
CABINET A
TOP VIEW
Frame
Crossbars
(Note 4)
Do not distort frame shim sides if required.
XX
3-1/2
(89)
DRYWALL
5/8"
It is recommended to leave 2” (51) minimum clearance
(16)
on both sides for removing panel
Cabinet
Flange
1.25 (32)
Notes:
1. Cabinet configuration will determine slab core drilling location and walls surrounding cabinet.
2. Recommend stud walls surrounding cabinet. Drywall and studs should not be attached or contacting cabinet for best
sound attenuation. Where possible п¬Ѓll gaps with sound absorbing material. Use iso pad under cabinet. Secure cabinet to
floor in two places at back.
3. Return air panel overlaps rough opening, allow minimum of 3 1/2" (89) dry wall to corner. Do not caulk panel to wall.
4. G Panel attaches to frame cross bars. Cabinet must be recessed behind wall.
5. Dimensions are in inches (mm). All studs nominal 2x4, 1.50 (38) x 3.50 (89).
6. For п¬Ѓlter access, pivot inner panel, open п¬Ѓlter access snap. For chassis removal, remove G Panel, remove 2 cross bars,
remove п¬Ѓlter panel, slide out chassis.
7. When outside air is required, 48A0100N04 motorized damper must be used, mixed air temperature must be no
lower than 45В°F (7В°C), no higher than 95 DB/75 WB, and not exceed 20% of total CFM. Contractor must supply
air duct, cut hole in stud, remove K.O., assemble and wire damper assembly.
Note: Use extreme weather temperatures.
8. For 2" MERV 13 п¬Ѓlter set cabinet 6.25" (158) from front of drywall.
9. If drywall flanges (2) are removed, cabinet can set back 5.00 (127).
9.00 x 2.00 KO (228 x 51)
Outside air opening,
.38
(10)
left or right side
to suit installation.
2
Upper cross bar
1
“G” Frame
1
Frame
1
Upper Cross Bar
1
Lower Cross Bar
Optional motorized damper (order
seperately) 48A0100N04 may be
installed on left or right side. Note 7
4.75 (120)
C
Frame Kit
R.O.
12-1/4
(311)
Kit
57-1/2
(1460) R.O.
28-5/8
(727)
Floor
3
Lower cross bar
3
24.12 (612)
Qty Description
Kit Part
1
2
FRONT VIEW
Size
A
B
C
D
Panel
D
19.25
48A0100N51 09-18 (489)
19
19-5/8
(483) (498)
21.50
(546)
48A0100N52 24-36 24.25
(616)
24-3/8
24
(610) (620)
25.50
(648)
59
(1599)
5-7/8*
(149)
4.50* (114)
* Dimension if cabinet is on floor.
Add if cabinet is on stand/pad.
G Panel
Perimeter
Panel
Mounting
Bracket
4 Panel
Mounting
Nuts
Front View
Frame Installed
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 56
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Hinged “G” Style Return Air Panel – AVHSG Series
Inner
Panel
Pivots
Open
.625 (16)
A
1.81
(46)
15
(380)
Outer
Panel
59.00
(1499)
Hinged
Inner
Panel
Locks
46.50
(1181)
To
Floor
Wall
4.50* (114)
From Floor
Surface
* - Dimension increases if cabinet is
Optional
Inner Panel
with Keyed Locks
on stand or pad
Optional
Inner Panel
with Grille
(stamped louvers)
for 24-36 only
Optional
Inner Panel with
holes to mount
ADA thermostat
Front View
Standard Panel
Notes:
Unit
AVHS
Digit 6
A
09- 18
1
21.50 (546)
24 - 36
3
25.50 (648)
1.
2.
3.
4.
Dimensions are in inches (mm).
Panel painted polar ice.
Inner panel pivots open 90В°, for filter replacement without removing panel.
Shipped as left-hand pivot, but can be field converted to right hand. Cannot convert
panel with grille, or ADA options.
5. Optional locks and/or louvered panel available.
6. Optional frame for recessed cabinet applications and damper assembly available. See
page 46.
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 57
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
AHH Series – Stainless Steel Braided Hose Kit
Specifications:
•
•
•
•
•
•
•
•
•
Designed for VHS water-source heat pump applications.
KevlarВ® reinforced EPDM core with ANSI 302/304 stainless steel outer braid.
Fire rated materials per ASTM E 84-00 (NFPA 255, ANSI/UL 723 & UBC 8-1).
MPT (External Pipe Thread) fitting at one end; swivel with NPSH thread connector (Internal Thread) at the other
end (seals via fiber or EPDM washer, shipped inside connection).
Swivel connection provides union between chassis and risers.
Brass fittings, stainless steel ferrules.
Temperature range of 15В°F [9В°C] to 180В°F [82В°C]. (Operation below 32В°F requires antifreeze)
Max. working pressure of 400 psi [2756 kPa].
Min. burst pressure of four times working pressure.
Physical Data
Unit
Part #
Inside
Diameter
inches
Length
feet [cm]
Working
Pressure
psi [kPa]
Min. Burst
Pressure
psi [kPa]
Min. Bend
Radius
inches [mm]
09, 12
AHH0503B
0.50
3 [91]
400 [2756]
1600 [11024]
2.5 [63.5]
15, 18
AHH0753B
0.75
3 [91]
400 [2756]
1600 [11024]
4.5 [114.3]
24-36
AHH1003B
1.00
3 [91]
400 [2756]
1600 [11024]
5.5 [139.7]
ACST Cabinet Stands
Specifications
• 1" to 12" (25 to 305) tall, 1" (25) increments
• 16 Gauge galvanized steel
• Attached to cabinet with 4 screws
• Field installed
• Optional ISO pad .06" (1.5) thick
Top, front and
back are open
C
Unit
A
B
09-18
18.86
[479]
18.25
[464]
24-36
23.86
[606]
23.25
[590]
C
1 to 12
(25 to 305)
Optional ISO pad
on bottom
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 58
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Thermostats
Two types of thermostats are available AT Series - require field to make wiring connections to screw terminals on thermostat. Cabinet construction for remote
thermostat with field supplied whip (wires long enough to reach wall thermostat location) use AT Series.
A91558 Series - are the AT Series thermostats with a wire harness factory assembled, 6” long wires terminating with 9
pin molex connector. Cabinet construction for remote mount thermostat with optional factory whip (15, 25, or 35 foot
(457, 762, or 1067 cm) wires terminate with 9 pin molex for quick connection to A91558 Series thermostats.
Customer supplied thermostats should be approved by ClimateMaster Engineering Department prior to using.
All cabinets are compatible with 2 speed thermostats (G2 or Y2).
A9155805 shown below is ATP32U03C with factory wire harness (pigtail).
Connection to DXM2 Control
Connection to CXM Control
A9155805 Thermostat
Compressor
Reversing Valve
Fan
24Vac Hot
24Vac Common
Fault LED
CXM
Y1
Blower
Relay
Y
Y2
O
O
G
G
R
R
C
C
L
AL1
A9155805 Thermostat
Compressor
High Speed
Reversing Valve
Fan
24Vac Hot
24Vac Common
Fault LED
DXM2
Y1
Y1
Y2
Y2
O
R
O/W2
G
R
C
L
C
AL1
G
Molex Connectors
Manual Changeover
Automatic Changeover
Digital
Fault Indicator
A9155801
X
X
X
X
X
X
ATA11U03
A9155802
X
X
X
X
X
ATA22U01
A9155804
X
X
X
X
X
X
ATP32U03C
A9155805
X
X
X
X
X
X
X
X
1 or 2*
X
ATC32U02C
A9155806
X
X
X
X
X
X
X
2*
X
Fan Speeds
DXM2
ATA11U01
Setback Override
Thermostat
Assembly with
Molex Connector
6” Pigtail
Programmable
Thermostat Only
CXM
Set Temperature Limits
Molex Connectors
1
2**
X
1 or 2*
*Fan speed change automatic through thermostat Y2 signal.
** - Manual speed change
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 59
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
TSL Options
Optional Cabinet Disconnect Switch
Located on control box access door. Can be accessed through slot in “G” Panel Frame. Classified as motor
disconnect. See Cabinet decoder.
Optional Cabinet Circuit Breaker
Located on control box access door. Can be accessed through slot in “G” Panel Frame. All 208/230V and 265V 15 and
20 amp classified as HACR breaker. 265V 25 amp and higher classified as supplemental breaker. See Cabinet decoder.
Optional Thermostat Wire Harness (WHIP)
Low voltage wire harness 15, 25, or 35 foot ending with 9-Pin Molex quick connector. Exits cabinet on top, left front
corner. Thermostat cable is rated CL-2. See Cabinet decoder. Can be encased in BX conduit as special, contact factory.
Optional Premium Seal
Located on cabinet filter panel, seal is upgraded to extruded rubber gasket for durability and long life.
Optional 2" Filter
2" filter improves air filtration and reduces maintenance.
Accessory Filters (Not available for every application - check blower table for ESP)
1" (25mm) thick, MERV 8, and MERV 11
2" (50mm) thick, MERV 8, MERV 11, and MERV 13
TSL Accessory Filter ESP Table
TSL with ECM Motor
Model
Max CFM
Max ESP
9
450
0.4
Accessory Filter Initial ESP
coil area
face velocity
Merv 8
sq ft
fps
1"
2"
1"
Merv 11
2"
Merv 13
2"
2.5
180
0.08
0.06
0.09
0.08
0.15
12
450
0.4
2.5
180
0.08
0.06
0.09
0.08
0.15
15
700
0.5
2.5
280
0.17
0.14
0.22
0.15
0.25
18
800
0.5
2.5
320
0.20
0.16
0.29
0.19
0.28
24
950
0.6
3.4
280
0.17
0.14
0.22
0.15
0.25
30
1150
0.6
3.4
340
0.22
0.16
0.33
0.20
0.30
36
1350
0.6
3.4
400
0.26
0.21
0.44
0.24
0.34
Optional Cabinet Stand
Heavy gauge galvanized sheet metal stand field-attached to bottom of cabinet (or as special factory-installed for
cabinets with risers attached) to lift cabinet off floor. Can order 1" to 12" (25 to 305 mm) heights (by 1" increments)
without or with isolation pad for reduced transmission of vibration to the floor. Contact factory.
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 60
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
ECM Blower Motor (Optional)
The ECM blower motor (optional) for TSL09 - 36 is
controlled directly by the DXM2 control board that
converts thermostat inputs and CFM settings to signals
used by the ECM motor controller. To take full advantage
of the ECM motor features, a communicating multi-stage
thermostat should be used (ATC32U**).
The DXM2 control maintains a selectable operating airflow
[CFM] for each heat pump operating mode. For each
operating mode there are maximum and minimum airflow
limits. See the ECM Blower Performance tables for the
maximum, minimum, and default operating airflows.
Airflow Configuration Screen on Communicating
Thermostat or (ACDU) Service Tool.
AIRFLOW SELECTION
HEAT STAGE 1
HEAT STAGE 2
AUXILIARY HEAT
EMERGENCY HEAT
COOL STAGE 1
COOL STAGE 2
COOL DEHUMID 1
COOL DEHUMID 2
CONTINUOUS FAN
HEAT OFF DELAY
COOL OFF DELAY
PREVIOUS
CFM
600
750
850
850
525
700
425
550
350
60
30
NEXT
Airflow levels are selected using the configuration
menus of a communicating thermostat (ATC32U0IC) or
configuration/diagnostic tool (ACDU02C and harness
11B0100N27). The configuration menus allow the installer
to independently select and adjust the operating airflow
for each of the operating modes. Air flow can be selected
in 25 CFM increments within the minimum and maximum
limits shown in the ECM Blower Performance Table. The
blower operating modes include:
• First Stage Cooling (Y1 & O)
• Second Stage Cooling (Y1, Y2, & O)
• First Stage Heating (Y1)
• Second Stage Heating (Y1 & Y2)
• Fan (G with no Y1, Y2, or W)
The ECM motor for all TSL models includes “soft start”
and “ramp down” features. The soft start feature is a
gentle increase of motor rpm at blower start up. This
creates a much quieter blower start cycle.
The ramp down feature allows the blower to slowly
decrease rpm to a full stop at the end of each blower
cycle. This creates a much quieter end to each blower
cycle and adds overall unit efficiency.
The ramp down, time can be changed, feature is
eliminated during an ESD (Emergency Shut Down)
situation. When the DXM2 ESD input is activated, the
blower and all other control outputs are immediately deactivated.
The ramp down feature (also known as the heating or
cooling “Off Delay”) is field selectable by the installer. The
allowable range is 0 to 255 seconds.
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 61
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Riser Definitions
Swaged 3” Deep
For A Dia. Riser
From Above
A Dia.
A Dia.
A
A Dia.
A Dia.
Shutoff
Valve
Assembly
A Dia.
B Dia.
6.00
(152)
MAX
3.00
(76)
B Dia.
Runout
Into
Cabinet
Bottom of
Cabinet
Runout
Into
Cabinet
Runout
Into
Cabinet
39.75
(1100)
3.00
(76)
(Note 10)
Drain Runout
Into Cabinet
Supply and Return Supply and Return
Transition Up
Straight
Runout
Into
Cabinet
C Dia.
Supply and Return
Transition Down
3.12
(79)
Drain
Transition Up
A
1.00
1.25
1.50
2.00
2.50
B
1.25
1.50
2.00
2.50
3.00
-
C
-
1.00
1.25
1.50
2.00
2.50
Runout
for Slave
Cabinet
(Note 8)
Bottom Capped
Supply and Return
Runout
Into
Cabinet
A
A
Drain Only
Master Supply and Return
Master Drain (Runout Lower)
Top Capped
Supply and Return
Top Capped
Drain
3.00
Notes:
1.
2.
3.
4.
5.
6.
7.
8.
9.
You must know water flow direction to determine if cabinet requires transition up or down.
Transitions can only change by one diameter (1" to 1Вј", 1Вј" to 1ВЅ", etc.)
Riser transition couplings and runouts are factory brazed.
All risers are factory pressure tested.
Standard riser diameters are 1", 1Вј", 1ВЅ", 2", 2ВЅ" and 3"nominal water tubing.
Copper Type M and L available.
Drain riser insulated standard. Supply and return insulated optional.
Master riser - contractor provides tubing from runout to slave cabinet if needed.
Shutoff has FPT for hose (1/2" for D1 (09), D2 (12); 3/4" for D3 (15), D4 (18); or 1" for D5 (24), D6 (30),
D7 (36).
10. If cabinet stand or thick ISO Pad is used, at installation add height/thickness to shutoff valve and drain
runout height. Verify riser shutoff height with plans before brazing.
Note: ClimateMaster units with motorized valve option have water high pressure switches. Do not design riser stack
where switch will not reset (trip - 300 PSI; Reset - 250 PSI).
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 62
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Riser GPM Definitions and Sizing
Riser GPM requirements and individual Unit GPM requirements are necessary to select the proper Riser Piping
diameters. Refer to this page to determine GPM requirement, then refer to Riser Diameter Sizing Table to
determine Riser Piping diameters.
Example is for bottom supply (upward flow) - bottom return (downward flow) system feed loop, both supply
and return will be same GPM. GPM's are dependent upon unit load and system loop water temperatures.
Please refer to Performance Charts for individual Unit GPM requirements.
Floor 4
TSL09
2.0 GPM
Unit GPM (UGPM) = Required gallon per minute from "Performance
Charts,"or GPM used in Climasize.
Note: For factory installed AFR check Flow Rate available (See Table)
Total Riser GPM (TRGPM) = The sum of, all Unit, GPM's on each Riser.
Floor 3
TSL12
3.0 GPM
Total GPM Per Floor (TGF) = Total GPM minus the sum of Unit GPM from
all floors above or below, depending on direction of flow.
Example: Four floors, Consisting of units sizes TSL36, TSL24, TSL12 and
TSL09, as shown in diagram. UGPM's are 9.0, 6.0, 3.0 and 2.0 respectively.
Floor 2
TSL24
6.0 GPM
TRGPM = 9.0 + 6.0 + 3.0 + 2.0 = 20 GPM.
Auto-Flow Regulator (US GPM) Code
5/8 Sweat
Floor 1
TSL36
9.0 GPM
Upward Flow:
Floor 1: TGF = 20
Floor 2: TGF = 11
Floor 3: TGF = 5
Floor 4: TGF = 2
Add all floor GPM's (TRGPM).
Total GPM minus floor 1 GPM.
Total GPM minus floors 1 and 2 GPM's.
Total GPM minus floors 1, 2, and 3 GPM's.
Downward Flow:
Floor 4: TGF = 20 Add all floor GPM's (TRGPM).
Floor 3: TGF = 18 Total GPM minus floor 4 GPM.
Floor 2: TGF = 15 Total GPM minus floors 1 and 2 GPM's.
Floor 1: TGF = 9 Total GPM minus floors 1, 2, and 3 GPM's.
7/8 SWEAT
Unit
09
Unit
12
Unit
15
Unit
18
Unit
24
Unit
30
Unit
36
C
1.5
–
–
–
–
–
–
D
2.0
2.0
–
–
–
–
–
E
2.5
2.5
2.5
–
–
–
–
F
3.0
3.0
3.0
3.0
–
–
–
G
–
3.5
3.5
3.5
–
–
–
H
–
–
4.0
4.0
4.0
–
–
J
–
–
–
5.0
5.0
5.0
–
K
–
–
–
–
6.0
6.0
6.0
L
–
–
–
–
7.0
7.0
7.0
M
–
–
–
–
–
8.0
8.0
N
–
–
–
–
–
–
9.0
P
–
–
–
–
–
–
10.0
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 63
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Riser Diameter Sizing
Refer to Riser GPM Definitions and Sizing for the prefix to this example.
Each TSL Vertical Stack unit has three riser pipes: supply, return, and drain. The following example will be for
Supply and Return riser pipe (from the top floor to the bottom floor), supply flow up and return flow down.
Note: If flows are both same direction, you will have to create two table 3's, Supply and Return
TOP CAP
From Table 1 (below) determine the proper riser diameter needed to
satisfy the required GPM's at each unit. Refer to Table 2 (below) for a
summary.
TSL 09
2 GPM
0.00/1.00
Floor 4
1.00/1.00
Top Cap - Top half of riser is eliminated and sealed.
Bottom Cap - Bottom half of riser is eliminated and sealed.
The following nomenclature is used to designate the diameters at the
top (always first) and bottom of each unit.
0.00/1.00 - Indicates top cap/1" bottom.
1.00/1.00 - Indicates 1" top/bottom.
1.00/1.25 - Indicates 1" top/1.25" bottom.
1.25/1.50 - Indicates 1.25" top/1.50"bottom.
(from this we develop Table 3)
TSL 12
3 GPM
Floor 3
1.00
Change in Riser
Diameter
1.25
TSL 24
6 GPM
Note:
Floor 2
TSL 36
9 GPM
1.25/1.50
Floor 1
Supply
Flow
Transitions limited to 1 nominal
diameter size larger or smaller within each floor (cabinet).
Return
Flow
Table 1
Maximum GPM
10
16
23
45
80
135
Nominal Riser
Diameter
1”
1-1/4”
1-1/2”
2”
2-1/2”
3”
Max GPM for 1" to 1ВЅ"sized for 4 FT per second maximum velocity
Max GPM for 2" to 3" sized for maximum Frictional Loss Pressure Drop= 4 FT/100 FT
Note:
Max GPM per NABB recommendation. Never exceed 6.5 FPS, excessive
noise and abrasion will occur.
Table 2
Table 4 (From IMC-2012 Table 307.2.2)
Table 3
Floor
TGF
Diameter From
Table 1
Nomenclature
per Unit
Description
Drain Diameter
Max Tonnage
4
2
1” [25.4]
0.00/1.00
Top Cap, w/1” Bot Feed
1" [25 mm]
40
3
5
1 [25.4]
1.00/1.00
1” Full Length Riser
1Вј" [32mm]
90
2
11
1.25” [31.8]
1.00/1.25
1” Top, 1.25” to 1st Floor
1ВЅ" [38mm]
125
1
20
1.50” [38.1]
1.25/1.50
1.25” Top, 1.50" Bottom
2" [51mm]
250
Values from Table 3 are to be entered on the Riser Piping Schedule of EZ Order.
Top diameter must match bottom diameter of floor above.
To calculate drain riser diameter, add up unit tonnage and use Table 4. Example has 6Вѕ tons,
so 1" diameter is adequate.
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 64
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Riser Length Definitions and Calculations
Total Riser Length (L) = FF of floor below + 2"(51)
THIRD
FLOOR
Floor To Floor Height (FF): Distance from top of slab to top of
above slab.
RRH=91
(2311)
Room Riser Height (RRH): = 91 (2311) for all TSL's.
Riser Tail (RT): Length of riser extending down from the cabinet.
Riser tail piece must extend a minimum of 5" (127) below slab.
RT = L – RRH
SECOND
FLOOR
RRH=91
(2311)
FF=110
(2794)
Slab thickness (ST); Slab thickness plus and additional material
added to slab prior to setting cabinets.
Calculating Riser Dimensions for Example:
8" finished slab all floors
FIRST
FLOOR
RRH=91
(2311)
B
BASEMENT
FF=104
(2642)
RT
ST=
8” (203)
SLAB
All
Floors
FIRST FLOOR - (Pick L depending how far below slab wanted)
L = 115 (292) Max Standard Length
RT = L – RRH = 115 (2921) – 91 (2311) = 24 (610)
SECOND FLOOR L = FF (Floor 1) + 2 (51) = 104 (2642) + 2 (51) = 106 (2692)
RT = L – RRH = 106 (2692) – 91 (2311) = 15 (381)
THIRD FLOOR L = FF (Floor 2) + 2 (51) = 110 (2794) + 2 (51) = 112 (2844)
RT = L – RRH = 112 (2844) – 91 (2311) = 21 (533)
Notes:
1. For calculating riser length do not include ISO pad or stand, except remember that below (B) on any floor should be 5 (127) or
more for ease of brazing. For risers installed before cabinet—ISO pad or stand does affect riser shutoff valve and drain stub
setting dimension from floor, add to 39.75 (1100) and 3.12 (79). Check plans before brazing.
2. If riser maximum is exceeded or RT is less than slab + 5" (127) see riser extension sizing.
3. For calculationg and entering on EZ, use full length even if top or bottom capped.
4. Dimensions are inches (mm).
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 65
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Riser Extension Definitions and Calculations
Joint Overlap 2 Places
2"
(51)
Riser Extension Length: Start with the floor to floor Dim. (FF) From this
subtract the room riser height and tail length. Then add 4" (102) for the two
joint overlaps.
Riser Extension Length = FF {First floor} - (RRH {First floor} + RT {Second floor})
+ 4" (102). Minimum extension is 10 (254). Reduce riser length, if needed.
Second
Floor
Slab
Thickness
Riser Tail (RT): Length of riser extending down from the cabinet. Riser tail must
extend a minimum of 5" (127) below slab, for ease of brazing.
Room Riser Height (RRH): 91 (2311) for TSL.
FF
First
Floor
Floor To Floor Height (FF): Distance from top of slab to top of above slab.
Slab thickness (ST); Slab thickness plus and additional material added to slab
prior to setting cabinets.
RRH
Special care must be taken in sizing riser lengths and tail lengths when:
A) Riser extensions are used.
B) Floor to floor heights vary.
C) Slab thickness varies from floor to floor.
RT
Floor
B
Above Slab
Calculate extension length for Floor A.
RT
13 (330)
Riser
Extension
3"(76) Swage
Example: Floor to floor (FF) = 120" (3048)
Room Riser Height (RRH) = 91" (2311)
RT (Floor above) = 13" (330).
Riser Extension: 120" - (13" + 91") + 4" = 20".
3048 - (330 + 2311) + 102 = 508 mm.
(FF) = 120
(3048)
Room Riser
Height
(RRH)
91 (2311)
Floor
A
All Slabs
8” (203)
Notes:
1. Example shown - riser extensions would be
ordered with Floor “A” and assembled between
“A” and “B”.
2. Riser and extension “A” Top and Riser “B”
bottom must be the same diameter. Extensions
cannot transition.
3. Extensions are shipped loose, bulk shipped to
minimize shipping cost.
4. Dimensions are inches (mm).
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 66
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
Shipping
Units Are Shipped FOB Factory
TSL Chassis can be shipped 2 ways.
1. Upright in carton 4 per pallet, see figure 1.
2. Upright inside cabinet (risers shipped separate or customer supplied) 4 per pallet, see figure 1.
TSL Cabinet will ship upright 4 per pallet, see figure 1.
Cabinets are palletized to maximize shipping density then grouped by unit size, building, and floor where possible.
Special shipping accommodations can be provided. Request added cost before quoting job, shipping cost could
increase significantly and any additional charges will be billed. Some examples include reduced number of units per
pallet, palletized specifically by riser, by floor, or over crating.
Vertical Shipping
Per 4 pack on pallet
Description
Height
Aprox. Quantity Per
53 foot Box Trailer
Approximate
Weight per
pallet
Length
Width
Chassis 09-12
40
40
50
120 single stacked
480
Chassis 09-12
40
40
100
240 double stacked
480
Chassis 15-18
40
40
50
120 single stacked
560
Chassis 15-18
40
40
100
240 double stacked
560
Chassis 24-36
50
48
52
96 single stacked
825
Chassis 24-36
50
48
104
192 double stacked
825
Cabinet 09-18
40
40
71
112 single stacked
500
Cabinet 24-36
50
48
71
72 single stacked
625
Cabinet with Chassis 09-12
40
40
71
112 single stacked
940
Cabinet with Chassis 15-18
40
40
71
112 single stacked
1020
Cabinet with Chassis 24-36
50
48
71
72 single stacked
1410
H
W
Figure 1
L
Fork
this
side
Small and Large cabinets can be mixed on some loads
88” Cabinets cannot have stands factory assembled, must ship loose or ship horizontal.
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 67
Revised: 16 December, 2014
Page ______ of ______
TSL Series 60Hz - HFC-410A Submittal Data
Eng/I-P
TranquilityВ® Modular - TSL Series
Engineering Specifications – Page 1
General:
Furnish and install ClimateMaster Tranquility® “TSL Vertical Stack” Water Source Heat Pumps, as indicated on the plans with
capacities and characteristics as listed in the schedule and the specifications that follow.
Units shall be supplied completely factory built capable of operating over an entering water temperature range from 20В° to 120В°F
(-6.7В° to 48.9В°C) as standard. Equivalent units from other manufacturers may be proposed provided approval to bid is given 10
days prior to bid closing. All equipment listed in this section must be rated and certified in accordance with Air-Conditioning,
Heating and Refrigeration Institute/International Standards Organization (AHRI / ISO 13256-1). All equipment must be tested,
investigated, and determined to comply with the requirements of the standards for Heating and Cooling Equipment UL-1995 for
the United States and CAN/CSA-C22.2 NO.236 for Canada, by Intertek Testing Laboratories (ETL). The units shall have AHRI / ISO
and ETL-US-C labels.
All units shall be fully quality tested by factory run testing under normal operating conditions as described herein. Quality control
system shall automatically perform via computer: triple leak check, pressure tests, evacuation and accurately charge system,
perform detailed heating and cooling mode tests, and quality cross check all operational and test conditions to pass/fail criteria.
Detailed report card will ship with each unit displaying status for critical tests and components. Note: If unit fails on any cross
check, it shall not be allowed to ship. Serial numbers will be recorded by factory and furnished to contractor on report card
for ease of unit warranty status. Units tested without water flow are not acceptable.
Basic Construction:
The cabinet construction is for ducted top discharge. The cabinet panels shall be fabricated from heavy gauge galvanized steel.
The rigid one-piece cabinet assembly shall be constructed so that it is self-supporting, and can be installed prior to the chassis
arrival, and to be able to avoid damage during construction. Top, base, fan deck, and other metal structural parts are to be 16
gauge construction, while exterior panels to be 20 gauge; unit further strengthened by structural breaks at corners. Units not
constructed of a minimum of these thicknesses are not acceptable. Cabinet shall have a full panel over the chassis opening for
structural rigidity of the cabinet; no “open” top or “open” bottom designs allowed.
The cabinet shall contain a secondary drain pan fully insulated with a pressure differential drain trap for field connection to the
condensate riser pipe, and guide rails for the slide in refrigeration chassis. Drain pan to be rubber grommet mounted to provide
isolation of chassis from the cabinet. Drain pan(s) shall be easily accessible for cleaning. All interior surfaces shall be lined with 1/2
inch (12.7mm) thick, 1-1/2 lb/ft3 (24 kg/m3) acoustic type fiberglass insulation. All insulation shall be foil faced and have exposed
edges butted up to flanges to prevent the introduction of glass fibers into the air stream.
Standard insulation must meet NFPA Fire Hazard Classification requirements 25/50 per ASTM E84, UL 723, CAN/ULC S102-M88
and NFPA 90A requirements; air erosion and mold growth limits of UL-181; stringent fungal resistance test per ASTM-C1071 and
ASTM G21; and shall meet zero level bacteria growth per ASTM G22. Unit insulation must meet these stringent requirements
or unit(s) will not be accepted.
Option: Isolation pad attached to bottom of cabinet for best sound attenuation.
Standard air filter is 1 inch (25mm) thick fiberglass throwaway.
Option: 2 inch (50mm) thick fiberglass throwaway.
Cabinet arrangements shall allow riser piping on any one of the three sides of the cabinet not used for the chassis access. Cabinet
to be top ducted. Ductwork to be field fabricated. Field shall configure cabinets by removing factory Riser knockouts per model
configuration shown on plans. Cabinet design shall allow a full height base board (4.50 inches/114mm) beneath the return air
panel. The cabinet shall contain an easily removable motor/blower assembly.
Electrical connections are direct into the control compartment.
Option: Low voltage 15, 25, or 35 foot (572, 762, or 1,067 cm) whip with molex-type connector A9155801, A9155802, A9155803,
A9155804, A9155805 or A9155806, thermostat assembly, which is thermostat model ATA11U01, ATA11U03, ATP21U01,
ATA22U01, ATP32U03C or ATC32U02C respectively with mating molex-type connector.
Option: Premium automotive grade rubber seal between cabinet inner panel and chassis.
Option: Cabinet to have harness for connection to A9155 Series thermostat mounted to ADA “G” return air panel.
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
LC1007 - 68
Revised: 16 December, 2014
Page ______ of ______
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement