J-200 J-210 | J-200 J-245 | J-200 J-235 | J-200 J-275 | Jacuzzi J-200 J-280, J-275, J-245, J-235, J-210 spa Owner's manual

Add to My manuals
64 Pages

The J-200 J-280, J-200 J-275, J-200 J-245, J-200 J-235, and J-200 J-210 spas are designed to provide years of trouble-free use. These spas are equipped with an advanced water filtration system and have multiple features such as an automatic filtration cycle, a multi-colored LED light system, and optional BLUEWAVE™ Spa Stereo System. These spas are equipped with a CLEARRAY® Water Purification System.

advertisement

Jacuzzi J-200 Spa Owner's Manual | Manualzz
OWNER’S MANUAL
J-200™ Collection
J - 280
J - 275
J - 245
J - 235
J - 210
2530-277A Rev. A
Attention New Spa Owner!®
Congratulations on the purchase of your new Jacuzzi spa! The following
is a list of automated functions performed by your spa. These functions are
listed below in an attempt to alleviate any operational concerns you may
have during the first 24 hours of ownership! Also listed below are important
maintenance recommendations you should observe on a regular basis to
protect your new investment.
Automated Operations
Approximately two minutes after power is applied to the spa, the first
filtration/heating cycle turns on pump 1. With two pump models, an automatic
five-minute “blow-out” function also activates pump 2 for a period of five
minutes to flush all lines. Then, after five minutes, pump 2 turns off and pump
1 continues to operate for the duration of the cycle.
Note: This function only occurs during the first filtration/heating cycle each
day.
Maintain Healthy Spa Water
Always maintain your spa’s water chemistry within the following parameters:
With CLEARRAY®
Without CLEARRAY®
pH
7.4-7.6
7.4-7.6
Free Chlorine
no less than 1.0 ppm
3.0-4.0 ppm
Free Bromine
no less than 2.0 ppm
2.0-4.0 ppm
Total Alkalinity
100-120 ppm
100-120 ppm
Calcium Hardness
150-250 ppm
150-250 ppm
IMPORTANT: CLEARRAY® Water Purification System is factory installed. If
the CLEARRAY® system is altered or is not operating efficiently then follow
the “without CLEARRAY®” water chemistry parameters as defined by the
Association of Pool and Spa Professionals. CLEARRAY® requires an annual
bulb replacement to properly sanitize your water.
! TO DECREASE RISK OF INFECTION OR DISEASE! Always maintain
your spas filter as outlined below to ensure healthy spa water. Refer page
39 “Water Quality Maintenance” for additional information.
Required Filter Maintenance
Your new spa is equipped with an advanced water filtration system that provides
unsurpassed water quality! To ensure maximum water quality at all times, you
should clean the filter cartridge once a month, or earlier as necessary. See page
32 for detailed filter cartridge cleaning/replacement instructions.
Required Water Replacement
! TO DECREASE RISK OF INFECTION OR DISEASE! You should
replace the spa’s water every 3 months. The frequency depends on a number
of variables including frequency of use, number of users, and attention paid to
water quality maintenance. You will know it is time for a change when you
cannot control sudsing and/or you can no longer get the normal feel or
sparkle to the water, even though the key water balance measurements are
all within the proper parameters. See page 39 for additional information.
© Jacuzzi Hot Tubs, Inc. All Rights Reserved
Table of Contents
J-200
1.0
2.0
Important Spa Owner Information���������������������������������������������� 1
FCC Notice����������������������������������������������������������������������������������� 1
3.0
3.1
3.2
3.3
3.4
Important Safety Instructions for all Spa Owners�������������������� 2
Entrapment Risk���������������������������������������������������������������������������� 6
Hyperthermia��������������������������������������������������������������������������������� 7
Important CSA Safety Instructions (Canada Only)������������������������ 8
General Electrical Safety Instructions�������������������������������������������� 8
4.0
4.1
4.2
Choosing A Location������������������������������������������������������������������� 9
Outdoor Location������������������������������������������������������������������������� 10
Indoor Location���������������������������������������������������������������������������� 10
5.0
6.0
7.0
8.0
General Electrical Safety Instructions������������������������������������� 11
Power Requirements����������������������������������������������������������������� 12
Electrical Wiring Instructions��������������������������������������������������� 14
Spa Fill Up Procedure��������������������������������������������������������������� 17
9.0
9.1
9.2
9.3
Control Functions���������������������������������������������������������������������� 22
Control Panel������������������������������������������������������������������������������� 22
General Spa Features and Controls�������������������������������������������� 23
General Spa Features and Controls (J-235/J-245/J-275)����������� 24
10.0
10.1
10.2
10.3
10.4
10.5
10.6
10.7
Operating Instructions�������������������������������������������������������������� 25
Setting Water Temperature���������������������������������������������������������� 25
Activate Jet Pumps���������������������������������������������������������������������� 26
Multi-Colored LED Light System Operation��������������������������������� 26
Adjusting Individual Jet Flow������������������������������������������������������� 26
Selecting Desired Massage Action���������������������������������������������� 26
Air Controls���������������������������������������������������������������������������������� 27
Optional BLUEWAVE™ Spa Stereo System (J-235 to J-280)����� 27
11.0
11.1
11.2
11.3
11.4
11.5
11.6
Automatic Filtration Cycles������������������������������������������������������ 28
Standard Filtration/Heating Modes���������������������������������������������� 28
Economy Filtration/Heating Modes (All Models)�������������������������� 28
Lock Modes - L1-L3 (All Models)������������������������������������������������� 28
Selecting The Filtration/Heating Mode���������������������������������������� 28
Filtration Modes for Spas������������������������������������������������������������� 28
Programming the CLEARRAY (Ultraviolet)
Water Purification System����������������������������������������������������������� 30
12.0
12.1
12.2
12.3
12.4
12.5
Spa Maintenance����������������������������������������������������������������������� 32
Cleaning The Filters�������������������������������������������������������������������� 32
Draining and Refilling������������������������������������������������������������������ 36
Pillow Care���������������������������������������������������������������������������������� 36
Cleaning The Spa Interior������������������������������������������������������������ 37
Vinyl Cover Care and Maintenance��������������������������������������������� 37
J-200
12.6
12.7
12.8
Maintaining The Synthetic Cabinet���������������������������������������������� 37
Winterizing����������������������������������������������������������������������������������� 38
Restarting Your Spa in Cold Weather������������������������������������������ 39
13.0
13.1
13.2
13.3
13.4
Water Quality Maintenance������������������������������������������������������� 39
pH Control����������������������������������������������������������������������������������� 40
Sanitizing������������������������������������������������������������������������������������� 40
CLEARRAY® Water Purification System������������������������������������ 41
CLEARRAY® Lamp Replacement and
Quartz Tube Maintenance����������������������������������������������������������� 42
14.0
14.1
14.2
14.3
14.4
14.5
14.6
14.7
14.8
Error Conditions/Error Messages�������������������������������������������� 45
Panel Displays COL��������������������������������������������������������������������� 45
Panel Displays ICE���������������������������������������������������������������������� 45
Panel Displays SN1��������������������������������������������������������������������� 45
Panel Displays SN2��������������������������������������������������������������������� 45
Panel Flashes FL1 or FL2����������������������������������������������������������� 45
Panel Displays OH���������������������������������������������������������������������� 46
Panel Displays (- - -)�������������������������������������������������������������������� 46
Panel Displays BLB��������������������������������������������������������������������� 46
15.0
15.1
15.2
15.3
15.4
15.5
Troubleshooting Procedures���������������������������������������������������� 46
None of the Components Operate (e.g. Pump, Light)����������������� 46
Pump Does Not Operate But Light Does������������������������������������� 47
Poor Jet Action���������������������������������������������������������������������������� 47
Water is Too Hot�������������������������������������������������������������������������� 47
No Heat��������������������������������������������������������������������������������������� 47
16.0
16.1
16.2
16.3
16.4
Circuit Board Diagrams������������������������������������������������������������ 48
North American J-235, J-245, J-275 and J-280 Models�������������� 48
North American J-210 Convertible Models���������������������������������� 49
Export 50 Hz J-235, J-245, J-275 and J-280 Models������������������ 50
Export 50 Hz J-210 Models��������������������������������������������������������� 51
17.0
17.1
17.2
17.3
17.4
17.5
17.6
17.7
Optional BLUEWAVE™ Spa Stereo System���������������������������� 52
Pairing the Remote and Stereo��������������������������������������������������� 53
Audio Settings����������������������������������������������������������������������������� 53
Wireless Remote Control Functions�������������������������������������������� 55
Electronic Device Connections and Functions���������������������������� 56
Wireless Remote Battery Replacement Procedure��������������������� 59
Bluewave Spa Stereo System Specifications������������������������������ 59
Stereo Cautions��������������������������������������������������������������������������� 60
J-200
1.0
Important Spa Owner Information
Your Jacuzzi J-200 Collection spa is constructed to the highest standards
and is capable of providing many years of trouble-free use. However,
because heat retentive materials are utilized to insulate the spa for
efficient operation, an uncovered spa surface and wall fittings directly
exposed to sunlight and high temperatures for an extended period are
subject to permanent damage. Damage caused by exposing the spa
to this abuse is not covered under warranty. We recommend that you
always keep the spa full of water when it is exposed to direct sunlight
and that you keep the Jacuzzi premium insulating cover in place at
all times when the spa is not in use. Read and carefully follow the
requirements for your spa’s support base found in Section 4.0 titled,
“Choosing A Location” (page 9).
Jacuzzi constantly strives to offer the finest spas available,
therefore modifications and enhancements may be made which
affect the specifications, illustrations and/or instructions contained
herein.
2.0
FCC Notice
This equipment has been tested and found to comply with the limits for
a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
1. Rearrange or relocate the receiving antenna.
2. Increase the separation between the equipment and receiver.
3. Connect the equipment into an outlet on a circuit different from the
circuit connected.
4. Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party
responsible for FCC compliance could void the user’s authority to
operate this equipment.
1
J-200
3.0
Important Safety Instructions for all Spa Owners
READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY!
This spa was manufactured to meet the standards and specifications
outlined in the “Virginia Graeme Baker Pool and Spa Safety Act” (VGB
Safety Act). When installing and using this spa, basic safety precautions
should always be followed, including:
! DANGER: RISK OF SEVERE INJURY OR DROWNING!
1.
• Extreme caution must be exercised to prevent unauthorized access
by children.
• To avoid accidents, ensure that children do not use this spa unless
supervised at all times. Adult supervision is a critical safety factor in
preventing children from drowning.
• Use the straps and clip tie downs to secure the spa cover when not
in use. This will help discourage unsupervised children from entering
the spa. Keep the spa cover secure in high-wind conditions.
• There is no representation that the cover, clip tie-downs, or actual
locks will prevent access to the spa.
! DANGER: RISK OF SEVERE INJURY OR DROWNING!
2.
• Keep hair, loose articles of clothing or hanging jewelry away from
suction fittings, rotating jets or other moving components to avoid
entrapment that could lead to drowning or severe injury.
• Never use the spa unless all suction guards, filter, filter lid, or
skimmer assembly are installed to prevent body and/or hair
entrapment.
• Never operate or use the spa if the filter, filter lid, or skimmer
assembly are broken or any part of the skimmer assembly is missing.
Please contact your dealer or nearest service center for service.
• The suction fittings and suction covers in this spa are sized to match
the specific water flow created by the pump(s). If it is necessary to
replace the suction fittings, suction covers or pump(s), be sure that
the flow rates are compatible and are in compliance with the VGB
Safety Act.
• Never replace a suction fitting or suction cover with one rated less
than the flow rate marked on the original suction fitting. Using improper
suction fittings or suction covers can create a body or hair suction
entrapment hazard that may lead to drowning or severe injury.
3.
•
2
DANGER: RISK OF SEVERE INJURY FROM ELECTRIC
SHOCK OR DEATH FROM ELECTROCUTION!
Install the spa at least 5 feet (1.5m), from all metal surfaces. As an
alternative, a spa may be installed within 5 feet of metal surfaces
if each metal surface is permanently connected (bonded) by a
minimum No. 8 AWG (8.4 mm²) solid copper conductor attached
to the wire connector on the grounding lug, inside the equipment
compartment on the equipment box.
!
J-200
•
•
•
•
•
•
A grounding wire connector is provided on this unit to connect a
minimum No. 8 AWG (8.4 mm²) solid copper conductor between
this unit and any metal equipment, metal enclosures of electrical
equipment, metal water pipe, or conduit within 5 feet (1.5m) of the
unit.
Never permit any electrical appliance, such as a light, telephone,
radio, television, etc. within 5 feet (1.5m) of a spa unless such
appliances are built-in by the manufacturer.
Never bring any electrical appliances into or near the spa.
Never operate any electrical appliances from inside the spa or when
you are wet.
The electrical supply for this product must include a suitably rated
switch or circuit breaker to open all ungrounded supply conductors
to comply with Section 422-20 of the National Electrical Code/USA,
ANSI/NFPA 70. The disconnecting means must be readily accessible
and visible to the spa occupant but installed at least 5 feet (1.5m),
from the spa.
The electrical circuit supplied for the hot tub must include a suitable
ground fault circuit interrupter (GFCI) as required by NEC Article
680-42.
! WARNING: RISK OF SEVERE INJURY OR DEATH!
4.
• Extreme caution must be exercised to prevent diving or jumping
into the spa or slipping and falling, which could result in
unconsciousness, drowning, or serious injury. Remember that wet
surfaces can be very slippery.
• Never stand, walk or sit on the top railing of the spa.
5.
•
•
•
•
•
•
!
WARNING: RISK OF HYPERTHERMIA (OVER-HEATING)
CAUSING SEVERE INJURY, BURNS, WELTS OR DEATH!
Water temperature in excess of 104°F (40°C) may be injurious to
your health.
Refer to Section 3.2 Hyperthermia for specific causes and symptoms
of this condition.
The water in the spa should never exceed 104°F (40°C). Water
temperatures between 100°F (38°C) and 104°F (40°C) are
considered safe for a healthy adult.
Lower water temperatures are recommended for young children
(children are especially sensitive to hot water) and when spa use
may exceed 10 minutes.
The Consumer Products Safety Commission/USA has stated that the
water temperature in a spa should not exceed 104°F (40°C).
Always test the spa water temperature before entering the spa.
The user should measure the water temperature with an accurate
thermometer since the tolerance of water temperature-regulating
devices may vary as much as +/- 5°F (2°C).
3
J-200
! WARNING: RISK OF SEVERE INJURY OR DEATH!
6.
• Since excessive water temperatures have a high potential for
causing fetal damage during the early months of pregnancy, if
pregnant or possibly pregnant, consult your physician before using a
spa.
• Pregnant or possibly pregnant women should limit spa water
temperatures to 100°F (38°C).
• Persons suffering from obesity or a medical history of heart disease,
low or high blood pressure, circulatory system problems, diabetes,
infectious diseases or immune deficiency syndromes should consult
a physician before using a spa.
• If you experience breathing difficulties in association with using or
operating your spa, discontinue use and consult your physician.
• Persons using medication should consult a physician before using
a spa since some medication may induce drowsiness, while other
medication may affect heart rate, blood pressure, and circulation.
• Persons suffering from any condition requiring medical treatment, the
elderly, or infants should consult with a physician before using a spa.
• The use of alcohol, drugs, or medication before or during spa use
may lead to unconsciousness with the possibility of drowning.
! WARNING: RISK OF SEVERE INJURY OR DEATH!
7.
• Prolonged immersion in a spa may be injurious to your health.
• Observe a reasonable time limit when using the spa. Exposures
at higher temperatures can cause high body temperature (overheating). Symptoms may include dizziness, nausea, fainting,
drowsiness, and reduced awareness. These effects could possibly
result in drowning or serious injury.
• Never use a spa immediately following strenuous exercise. Enter
and exit the spa slowly. Wet surfaces can be slippery.
8.
•
•
•
4
!
WARNING: TO DECREASE RISK OF INFECTION OR
DISEASE!
To reduce the risk of contracting a waterborne illness (e.g. an infection, bacteria or virus) and/or respiratory ailments, maintain water
chemistry within the parameters listed on the inside cover of this
manual and consult with a licensed engineer regarding proper ventilation if installed indoors or in an enclosed area.
People with infectious diseases should not use a spa to avoid water
contamination, which could result in spreading infections to others.
Always shower before and after using your spa. Maintain water
chemistry in accordance with manufacturer’s instructions. Failure to
do so may result in contracting a waterborne illness (e.g. an infection,
bacteria or virus).
J-200
! WARNING: In addition to maintenance of filters and water
chemistry, proper ventilation is recommended to reduce the risk of
contracting a waterborne illness (e.g. an infection, bacteria or virus)
and/or respiratory ailments that could be present in the air or water.
Consult a licensed architect or building contractor to determine your
specific needs if installing your hot tub indoors.
9.
10. CAUTION: TO DECREASE RISK OF PRODUCT DAMAGE.
• Maintain water chemistry in accordance with manufacturer’s
instructions.
• Proper chemical maintenance of spa water is necessary to maintain
safe water and prevent possible damage to spa components.
11.
!
WARNING: RISK OF SEVERE INJURY OR DEATH! The
appliance is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of
experience or knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person
responsible for their safety.
12. NOTE: This spa is not intended nor designed to be used in a commercial or public application. The spa buyer shall determine whether
there are any code restrictions on the use or installation of this spa
since local code requirements vary from one locality to another.
Hot Tub Safety Literature
To ensure you have a safe and enjoyable hot tub experience,
learn all you can about hot tub safety and emergency procedures.
Especially useful are the brochures listed below:
• Children Aren’t Waterproof
• Pool and Spa Emergency Procedures For Infants and Children
• Layers of Protection
• The Sensible Way to Enjoy Your Spa or Hot Tub
The Association of Pool and Spa Professionals publishes these
brochures. To acquire a brochure:
• Ask your hot tub dealer (they may have copies)
• Go to http://apsp.org
• Conduct your own search on the internet
• Write to the following address:
The Association of Pool and Spa Professionals
2111 Eisenhower Avenue
Alexandria VA 22314
703.838.0083
5
J-200
3.1
Entrapment Risk
The Consumer Products Safety Commission/USA has reported that
users of pools and spas have become entrapped (stuck) to drain and/or
suction fittings causing death, drowning, or serious injury (see diagram
below). This spa was manufactured to meet the standards and specifications outlined in the “Virginia Graeme Baker Pool and Spa Safety Act”
(VGB Safety Act). Entrapment risk can be minimized if proper precautions are taken.
DANGER:
RISK OF PERSONAL INJURY OR DEATH!
Never operate the spa if a suction fitting, suction cover,
filter, filter lid or skimmer assembly are broken, damaged or
missing.
!
J-280 Assembly
J-210/J-235/
J-245/J-275
Assembly
Filter, Filter
Lid, Skimmer
Assembly,
Floating Weir,
(location and
style vary by
models)
Suction Fittings,
Suction Covers
(locations vary
by models)
Note: Suction covers must be replaced every 5 years.
1.
•
•
•
2.
•
•
6
DANGER: RISK OF SEVERE INJURY OR DROWNING!
Hair entrapment: May occur if hair is entangled, knotted or snagged
in a drain suction or skimmer assembly. This has been reported in
persons who when submerge themselves underwater, allowing hair
to come close and/or within the reach of the suction fittings, suction
covers or skimmer assembly.
Keep hair away from suction fittings, suction covers, filter, filter lid or
skimmer assembly.
Children are at risk for hair entrapment if swimming under water.
Never allow children to play or get near the suction fittings, suction
covers, filter, filter lid or skimmer assembly.
!
DANGER: RISK OF SEVERE INJURY OR DROWNING!
Limb entrapment: May occur when a limb becomes entrapped,
inserted or sucked into a suction or outlet opening.
Always keep suction fittings, suction covers, filter, filter lid or skimmer
assembly in place when operating to avoid limb entrapment.
Never allow children to play or get near the suction fittings, suction
covers, filter, filter lid or skimmer assembly.
!
J-200
3.
•
4.
•
•
5.
•
•
! DANGER: RISK OF SEVERE INJURY OR DROWNING!
Body entrapment: May occur when part of the torso becomes
entrapped, inserted or sucked into a suction or outlet opening.
Never allow children to play or get near the suction fittings, suction
covers, filter, filter lid or skimmer assembly.
DANGER: RISK OF SEVERE INJURY OR DROWNING!
Evisceration (disembowelment) entrapment: May occur when the
buttocks becomes entrapped, inserted or sucked into a suction or
outlet opening.
Never sit on suction fittings, suction covers, filter, filter lid or skimmer
assembly.
Never allow children to play or get near the suction fittings, suction
covers, filter, filter lid or skimmer assembly.
!
DANGER: RISK OF SEVERE INJURY OR DROWNING!
Mechanical entrapment: May occur when jewelry, swimsuit, or
hair accessories become entangled, knotted or snagged in a drain
suction or skimmer assembly.
Never allow your jewelry, swimsuit, or hair accessories to come close
to the suction fittings, suction covers or skimmer assembly.
Never allow children to play or get near the suction fittings, suction
covers, filter, filter lid or skimmer assembly.
!
3.2
Hyperthermia
Prolonged immersion in hot water may induce hyperthermia (overheating). The use of alcohol or drugs can greatly increase the risk of fatal
hyperthermia in spas. A description of the causes, symptoms, and effects
of hyperthermia are as follows.
Hyperthermia occurs when the internal temperature of the body reaches
a level several degrees above the normal body temperature of 98.6°F
(37°C). The symptoms of hyperthermia include drowsiness, lethargy
(fatigue), and an increase in the internal temperature of the body. The
effects of hyperthermia include:
•
•
•
•
•
•
Unawareness of impending hazard;
Failure to perceive heat;
Failure to recognize the need to exit spa;
Physical inability to exit spa;
Fetal damage in pregnant women; and
Unconsciousness and DANGER of drowning.
A Warning Sign is provided in your warranty packet. Please install at
a location near your spa, where it is visible to users of the spa. For
additional or replacement Warning Signs please contact your local
Jacuzzi dealer and reference item number #6530-082.
7
J-200
3.3
Important CSA Safety Instructions (Canada Only)
When using this electrical equipment, basic safety precautions should
always be followed, including the following:
1. READ AND FOLLOW ALL INSTRUCTIONS.
2. A green colored terminal or a terminal marked G, Gr, Ground,
Grounding or the
symbol* is located inside the supply terminal box
or compartment. To reduce the risk of electric shock, this terminal
must be connected to the grounding means provided in the electric
supply service panel with a continuous copper wire equivalent in size
to the circuit conductors that supply this equipment (*IEC Publication
417, Symbol 5019).
3. At least two lugs marked “Bonding Lugs” are provided on the
external surface or on the inside of the supply terminal box/
compartment. To reduce the risk of electric shock, connect the local
common bonding grid in the area of the spa to these terminals with
an insulated or bare copper conductor not smaller than No. 6 AWG
(10 mm²).
4. All field installed metal components such as rails, ladders, drains or
other similar hardware within 10 feet (3m) of the spa shall be bonded
to the equipment grounding buss with copper conductors not smaller
than No. 6 AWG (10 mm²).
5. SAVE THESE INSTRUCTIONS.
3.4
General Electrical Safety Instructions
Your new Jacuzzi spa is equipped with a “state-of-the-art” equipment
system. It contains the most advanced safety and self-protective
equipment in the industry. Nonetheless, this spa must be installed
properly to ensure dependable usage. Please contact your local Jacuzzi
dealer or local building department should you have any questions
regarding your installation.
Proper grounding is extremely important. Jacuzzi spas are equipped with
a current collector system. A pressure wire connector is provided on the
surface of the control box, located outside the equipment door (Figure
B, page 16) to permit connection of a bonding wire between this point
and any ground metal equipment, metal water pipe or conduit within 5
feet (1.5m) of the spa, or copper clad grounding rod buried within 5 feet
(1.5m) of the spa. Bonding wire must be at least No. 8 AWG (8.4 mm²)
solid copper wire. This is a most important safety assurance feature.
Before installing your spa, check with your local building department to
insure installation conforms to local building codes.
8
J-200
4.0
Choosing A Location
IMPORTANT: Because of the combined weight of the spa, water and
users, it is extremely important that the base upon which the spa rests
be smooth, flat, level and capable of uniformly supporting this weight,
without shifting or settling, for the entire time the spa is in place. If the
spa is placed on a surface which does not meet these requirements,
damage to the skirt and/or the spa shell may result. Damage caused by
improper support is not covered under warranty. It is the responsibility
of the spa owner to assure the integrity of the support at all times.
We recommend a poured, reinforced concrete slab with a minimum
thickness of 4 inches (10 cm). Wood decking is also acceptable
provided it is constructed so that it meets the requirements outlined
above.
!
WARNING: For spas that are to rest on balconies,
roofs or other platforms not specifically tied into main
structural support, consult a professional Structural
Engineer with experience in this type of application.
The spa must be installed in such a manner as to provide drainage away
from it. Placing the spa in a depression without provisions for proper
drainage could allow rain, overflow and other casual water to flood the
equipment and create a wet condition in which it would sit in. For spas
which will be recessed into a floor or deck, install so as to permit access
to the equipment, either from above or below, for servicing. Make certain
that there are no obstructions which would prevent removal of all side
cabinet side panels and access to the jet components, especially on the
side with the equipment bay.
!
CAUTION: If the spa is indoors or located in an enclosed area,
proper ventilation should be discussed with an Engineer or authority
competent enough to understand the necessary provisions needed
to vent moist or heated air and air associated with chemical odors
outdoors. When the spa is in use considerable amounts of
moisture will escape potentially causing mold and mildew. This
can cause health risk. Over time, this can damage certain surfaces,
surroundings, and equipment.
9
J-200
4.1
Outdoor Location
In selecting the ideal outdoor location for your spa, we suggest that you
take into consideration:
•
•
•
•
•
•
•
•
•
The proximity to changing area and shelter (especially in colder
weather).
The pathway to and from your spa (this should be free of debris so
that dirt and leaves are not easily tracked into the spa).
The closeness to trees and shrubbery (remember that leaves and
birds could create extra work in keeping the spa clean).
A sheltered environment (less wind and weather exposure can result
in lowered operation and maintenance costs).
The overall enhancement of your environment. It is preferable not to
place the spa under an unguttered roof overhang since run-off water
will shorten the life expectancy of the spa cover.
For spas that are to rest on balconies, roofs or other platforms not
specifically tied into main structural support, consult a professional
Structural Engineer with experience in this type of application.
In the unlikely event that you should ever need to access or gain
entry to any portion of the spa for servicing, it is highly recommended
that you plan your outdoor installation to provide full access to the
entire spa. Please take this into consideration when placing the spa
in a deck or enclosed by a surrounding.
Consider locating your spa away from any reflective surface or glass
to prevent any damage to the synthetic skirt.
Do not shim the spa. To ensure proper support the spa must sit flat
on the intended foundation.
4.2
Indoor Location
For indoor installations many factors need to be considered before
installing a spa indoors:
!
•
10
WARNING: In addition to maintenance of filters and water
chemistry, proper ventilation is recommended to reduce the
risk of contracting a waterborne illness (e.g. an infection,
bacteria or virus) and/or respiratory ailments that could be
present in the air or water. Consult a licensed architect or
building contractor to determine your specific needs if
installing your hot tub indoors.
Proper Foundation: Consult a Structural Engineer when
considering a foundation that will adequately support the spa
the entire time it is in place. Proper support is critical especially
if the spa is to rest on a second story or higher. For spas that are
to rest on balconies, roofs or other platforms not specifically tied
into the main structural support, you should consult a professional
Structural Engineer with experience in this type of application.
J-200
•
•
•
•
•
5.0
Proper Drainage: It is extremely important to have in place
measures to sufficiently handle excessive water spillage. Be
sure the flooring in which the spa rests on has adequate drainage
and can handle the entire contents of the spa. Be sure to make
provisions for ceilings and other structures that may be below the
spas installation. Areas around your spa can become wet or moist so
all flooring and subsequent furniture, walls and adjacent structures
should be able to withstand or resist water and moisture.
Proper Ventilation: Proper ventilation should be discussed with
an Engineer or authority competent enough to understand the
necessary provisions needed to vent moist or heated air and air
associated with chemical odors outdoors. When the spa is in use
considerable amounts of moisture will escape, potentially causing
mold and mildew over time which can damage certain surfaces and/
or surroundings.
Sufficient Access: In the unlikely event that you should ever need
to access or gain entry to any portion of the spa for servicing, it is
highly recommended that you plan your indoor installation to provide
full access to the entire spa.
Warranty: Damage caused by not following these guidelines or any
improper installation not in accordance to local codes or authorities is
not covered under the spas warranty. Please consult your local state
or city building ordinances.
Do not shim the spa. To ensure proper support the spa must sit flat
on the intended foundation.
General Electrical Safety Instructions
Your new Jacuzzi spa is equipped with a “state-of-the-art”
equipment system. It contains the most advanced safety
and self-protective equipment in the industry.
Nonetheless, this spa must be installed properly to insure
dependable usage. Please contact your dealer or local
building department should you have any questions regarding your
installation.
Proper grounding is extremely important. Jacuzzi spas are equipped with
a current collector system. A pressure wire connector is provided on the
surface of the control box, located outside the equipment door (Figure
B, page 16) to permit connection of a bonding wire between this point
and any ground metal equipment, metal water pipe or conduit within
5 feet (1.5m) of the spa, or copper clad grounding rod buried within 5 feet
(1.5m) of the spa. Bonding wire must be at least No. 8 AWG (8.4 mm²)
solid copper wire. This is a most important safety assurance feature.
Before installing this spa, check with the local building department to
insure installation conforms to local building codes.
11
J-200
120/240 Volt Convertible Models
A spa connected to a 120 VAC electrical service must be located close
enough to a grounded, grounding-type electrical outlet so that the
included 10 feet (3m) power cord can be plugged directly into it. DO NOT
USE AN EXTENSION CORD as this could cause damage to the spa’s
equipment due to insufficient voltage. The power supplied to this spa
must be a dedicated circuit with no other appliances or lights sharing the
power provided by the circuit.
6.0
Power Requirements
Jacuzzi spas are designed to provide optimum performance and
flexibility of use when connected to the maximum electrical service listed
below. Minor circuit board modifications can be performed to allow your
new spa to accept an electrical service other than the factory operation
setting.
Note: Refer to pages 48-51 for circuit board configuration details or
contact your authorized Jacuzzi dealer.
All North American J-210 Convertible Models (60 Hz)
120V/15A†
240V/30A†
240V/40A‡
Circuit Breaker:
15A†, 1-Pole
30A†, 2-Pole
40A‡, 2-Pole
Number of Wires:
3 (15A GFCI
Cord US
Only*)
4 (Hard Wire
Only)
4 (Hard Wire
Only)
60 Hz
60 Hz
60 Hz
12A
21A
30A
Frequency:
Current Draw:
† In 15A/30A configuration, the heater will not operate while the jets
pump is running in high speed. The factory setting is 120V/15A.
‡ In 40A configuration, remove jumper JP1-2 on the board, to allow the
heater to operate when the jets pump is running in high speed.
CAUTION (For 4-wire 240 VAC Heater Operation): Move the red
wire on the main terminal strip (TB1) from position #1 to position
#3. Make certain wires are connected exactly as shown in Figure
D (Page 16) before applying power. Failure to do so will result in
damage to the circuit board and/or related components and void
the manufacturer’s warranty.
12
J-200
All North American J-235/J-245/J-275/J-280 Models (60 Hz)
Circuit Breaker (2-Pole):
Number of Wires:
Frequency:
Current Draw:
240V/40A*
240V/50A**
240V/60A***
40A*
50A**
60A***
3
3
3
60 Hz
60 Hz
60 Hz
26A
36A
45A
In 40A configuration, the heater will not operate while either jets
pump is running in high speed. Note: pump 2 runs only in high
speed.
In
50A configuration, the heater will not operate while both jets
**
pumps are running in high speed. This is the factory setting.
Note: pump 2 runs only in high speed.
*** In 60A configuration the heater will operate while both jets pumps
are running in high speed.
*
Export J-235/J-245/J-275/J-280 Models (50 Hz)
Circuit Breaker:
Number of Wires:
Frequency:
Current Draw:
230V/20A*
230V/30A**
230V/40A***
20A*
30A**
40A***
3
3
3
50 Hz
50 Hz
50 Hz
15A
23A
29A
In 20A configuration, the heater will not operate while either jets
pump is running in high speed. This is the factory setting. Note:
pump 2 runs only in high speed.
** In 30A configuration, the heater will operate while one jets pump
is running in high speed. Note: pump 2 runs only in high speed.
*** In 40A configuration the heater will operate while both jets pumps
are running in high speed.
*
Export J-210 Models (50 Hz)
Circuit Breaker:
Number of Wires:
Frequency:
230V/20A*
230V/30A**
20A*
30A**
3
3
50 Hz
50 Hz
Current Draw:
15A
21A
* In 20A configuration, the heater will not operate while the jets
pump is running in high speed. This is the factory setting
** In 30A configuration, the heater will operate while the jets pump is
running in high speed.
13
J-200
7.0
Electrical Wiring Instructions
IMPORTANT NOTICE: The electrical wiring of this spa
must meet the requirements of the National Electrical
Code/USA (NEC) and any applicable state or local codes.
The electrical circuit must be installed by a qualified
electrician and approved by a local building/electrical inspection authority.
1. Convertible 120/240V Power Models:
•
•
! DANGER: TO DECREASE THE RISK OF SHOCK,
PRODUCT DAMAGE OR ELECTRICAL FIRE.
120V “Plug-in” Operation: This spa must operate on the supplied
120V GFCI cord at its original length or must be hard-wired for longer
runs. NEVER USE AN EXTENSION CORD FOR ANY REASON!
Convertible 120/240V heater Operation: The included 120V
GFCI cord must be discarded for 240V heater operation. This spa
must be hard wired. Supplying power to either configuration above
which is not in accordance with these instructions will void both the
independent testing agency listing and the manufacturer’s warranty.
2. Dedicated 230V-240V models must be permanently connected
(hard-wired) to the power supply. No plug-in connections or
extension cords are to be used in conjunction with the operation
of this spa. Supplying power to the spa which is not in accordance
with these instructions will void both the independent testing agency
listing and the manufacturer’s warranty.
3. The power supplied to this spa must be a dedicated circuit with no
other appliances or lights sharing the power provided by the circuit.
4. To determine the current, voltage and wire size required, refer to
Section 6.0 “Power Requirements” (page 12).
• Wire size must be appropriate per NEC/USA and/or local codes.
• We recommend type THHN wire.
• All wiring must be copper to ensure proper connections. Do not use
aluminum wire.
• When using wire larger than #6 (10 mm²), add a junction box near
the spa and reduce to short lengths of #6 (10 mm²) wire to connect
to the spa.
5. The electrical supply for this product must include a suitably rated
switch or circuit breaker to open all ungrounded supply conductors
to comply with Section 422-20 of the National Electrical Code/USA,
ANSI/NFPA 70. The disconnecting means must be readily accessible
to the spa’s occupant but installed at least 5 feet (1.5m) from spa
water.
14
J-200
6. The electrical circuit supplied for the spa must include a suitable
ground fault circuit interrupter (GFCI) as required by NEC/USA Article
680-42.
7. To gain access to the spa’s power terminal block, remove the screws
securing the synthetic cabinet panel under the control panel (Figure
A). Then remove the four control box door screws and door (Figure B).
8. Select the power supply inlet you want to use (Figure A). Feed power
cable to control box, then install it through the large opening provided
in the bottom side of the box.
9. Connect wires, color to color, on terminal blocks TB1 and TB3
(Figure C, page 16). TIGHTEN SECURELY! All wires must be
hooked up securely or damage could result.
10. Install control box door and screws and reinstall the cabinet side
panels.
Figure A
Equipment Area
9
1
WARNING!
DONOT LOOK AT LIT BULB
4
6
2
SEVERE EYE DAMAGE
OR BLINDNESS CAN OCCUR
8
5
7
3
5
2
Note: Equipment location (such as pumps, CLEARRAY system, drain, heater etc.) varies by model.
1.
2.
3.
4.
5.
Control Box
Power Supply Inlet(s)
2-Speed Pump
Heater
Pump Drain Plug
6.
7.
8.
9.
1-Speed Pump
CLEARRAY Water Purification System
Electronic Ballast (for CLEARRAY System)
Control Panel
15
J-200
Figure B
Control Box
1.
2.
3.
2
TB1
Terminal Block
Bonding Lug
Grounding Terminal
1
3
WHT
TB1
RED
1
Figure-D
WHT
to Circuit
Board
3
WHT
RED
BLK
BLK
BLK
2
TB1
1
BLK
BLK
Power In
WHT
Power In
Figure-C
BLK
2
RED
RED
3
to Circuit
Board
GRN
GRN
North American Convertible
Models: 120 VAC, 3-Wire Connection
60 Hz
Move Red
Wire Here
North American Convertible
Models: 240 VAC, 4-Wire Connection
60 Hz
CAUTION (For 4-wire 240 VAC Heater Operation): Move the red
wire on the main terminal strip (TB1) from position #1 to position
#3. Make certain wires are connected exactly as shown in Figure
D before applying power. Failure to do so will result in damage
to the circuit board and/or related components and void the
manufacturer’s warranty.
RED
1
Power In
BLK
2
Green
TB1
RED
TB2
Figure-F
1
RED
2
BLK
BLK
to Circuit
Board
TB3
North American 240V Models:
240 VAC, 3-Wire Connection 60 Hz
TB1
1
BLUE
BLUE
BROWN
BROWN
Power In
Figure-E
2
Green
TB1
to Circuit
Board
TB3
All Export Models: 230 VAC, 3-Wire
Connection 50 Hz
Congratulations! You are now all set to get your new spa ready to use.
Simply follow the step-by-step procedure in Section 8.0, before long,
you will be enjoying your first glorious experience in your Jacuzzi J-200
Collection spa.
16
J-200
8.0
Spa Fill Up Procedure
For best results, read each step in its entirety before proceeding with that
step.
1. Prepare The Spa For Filling
• Clear all debris from the spa. (Although the spa shell has been
polished at the factory, you may want to treat it with a specially
formulated spa cleaner.) Consult your authorized Jacuzzi dealer for
additional information prior to filling spa.
• Remove filter cover, then remove filter cartridge as outlined in
Section 12.1 (page 32).
2. Fill Spa
• Place the end of your garden hose into the empty filter bucket.
CAUTION: TO DECREASE BUILD UP ON COMPONENTS AND
MINIMIZE ACRYLIC DAMAGE.
Never fill with water from a water softener. If your water is extremely
“hard,” it is preferable to fill half-way with hard water and the rest of
the way with softened water. Water that is too soft can be corrosive
to metal components.
•
! WARNING: TO DECREASE RISK OF INFECTION OR
DISEASE.
Fill hot tub with clean tap water from garden hose, to reduce risk of
contracting a waterborne illness (e.g. an infection, bacteria or virus)
and/or respiratory ailments. Fill until water covers all jets but does not
touch the bottom of the lowest headrest. (DO NOT OVERFILL!)
IMPORTANT: Always fill your spa through the filter bucket after
draining. Failure to do so may cause air to be trapped in either
pump, preventing the pump from circulating water. Remove the
hose and replace the filter cartridge. Note: DO NOT overtighten filter
cartridge, finger tight only!
3. Turn On Power
Turn on power to spa at the home’s circuit breaker to start boot up
sequence (Sec. 10.0, page 25). The heater and filter pump will
automatically activate after several seconds. If the control panel LED
flashes water temperature and “COL” or “ICE” this is normal, refer to
page 45 for additional information.
Note: “COL” and “ICE” will only appear when the spa is in Economy
mode.
4. Activate Jets Pumps
Turn on jets pump(s) to ensure proper mixing when
adding start-up chemicals in step 5.
1
2
17
J-200
5. Add Start-Up Chemicals
Add the spa water chemicals as recommended by your authorized
Jacuzzi dealer. See Section 13.0 “Water Quality Maintenance” (page
39) for general guidance.
!
WARNING: RISK OF POISONING OR DEATH.
Never leave chemicals opened and accessible to anyone.
Use chemicals according to the vendors instructions. Always
store chemicals in a safe and/or locked location. Keep away
from and out of reach of children.
6. Establish A Stable Sanitizer Reading
Establish a stable sanitizer reading of no less than 1.0 ppm free
chlorine or 2.0 ppm bromine. To ensure healthy water conditions,
always maintain a constant sanitizer reading within the levels
recommended on the inside cover of this manual. If sanitizer levels
cannot be stabilized, perform the decontamination procedure steps
9-15 on the following page.
Note: The “decontamination procedure” steps 9-16 should also be used
after the spa has been “Winterized” (Section 12.7, page 38) or has
been sitting without power for an extended period.
7. Set Spa To Heat
To warm spa water to a comfortable temperature, follow
these steps:
• The LED display on the control panel displays the
actual temperature of the spa water. Press either the
COOLER ( ) or WARMER ( ) button once to display the “set”
temperature for 5 seconds. If you want the water to heat to a different
temperature, simply press COOLER ( ) or WARMER ( ) within 5
seconds. The set temperature increases or decreases by one degree
each time one of these buttons is pressed.
• The heater will turn off when the temperature corresponding to the
thermostat setting is achieved.
Important Heater Details:
• The maximum water temperature setting for your spa is 104°F
(40°C) and the minimum setting is 65°F (18°C).
• For North America spas connected to a 40 amp service, jets pump
#1 must be set to low speed and jets pump #2 must be turned off to
operate the heater.
• For Export spas connected to a 20 amp service, jets pump #1 must
be set to low speed and jets pump #2 must be turned off to operate
the heater.
• Setting the thermostat at maximum will not accelerate the heating
process. This will only result in a higher ultimate temperature.
• The heater operates until the water reaches the programmed “set
temperature,” then turns off. The heater will reactivate after the
water cools to approximately 1.5° below the set temperature.
18
J-200
8. Place Cover On Spa
• Keeping the insulating cover in place anytime the spa is not in
use will reduce the time required for heating, thereby minimizing
operating costs.
• The time required for initial heat-up will vary depending on the
starting water temperature.
!
DANGER:
RISK OF PERSONAL INJURY.
Check water temperature carefully before entering hot tub!
Excessive water temperature can cause burns, welts and
body temperature to rise, hyperthermia (over-heating).
Decontamination Procedure (Steps 9-16)
Steps 9-16 below are only required when sanitizer levels are unstable
after performing steps 1-6 above. Disregard steps 9-15 below if sanitizer
levels remain stable after performing steps 1-6 above (refer to the inside
cover of the manual).
9. Add 2.5 ounces of sodium dichlor for every 100 gallons of water.
Refer to the table below for approximate water fill volume by model.
!
CAUTION: RISK OF PERSONAL INJURY OR SPA DAMAGE!
Never add chlorine tablets (trichlor) or acid to your hot tub
for any reason! These chemicals may damage components
within your hot tub, burn or irritate your skin, create a rash,
and void the manufacturer warranty for your spa.
Water Fill Volume by Model
Model
Average Fill Volume*
Sodium Dichlor
J-280
460 Gal (1,741 L)
12.0 oz
J-275
420 Gal (1,590 L)
10.5 oz
J-245
360 Gal (1,363 L)
9.0 oz
J-235
360 Gal (1,363 L)
9.0 oz
J-210
240 Gal (908 L)
6.0 oz
*Use average fill volume for chemical maintenance
19
J-200
10. Leave spa cover open during this step to allow
excessive chemical vapors to exit spa, protecting
pillows and plastic knobs from chemical attack. If spa
is indoors, open doors and windows for proper
ventilation. Turn on all jet pumps for one hour, then
place the massage selector knob (if equipped) in the
center “combo” position and open all air controls
(Figure A is for all models except the J-210). For the
J-210 models (Figure B) turn the Diverter Jet in the
“combo” position.
Note: You will need to press the jets pump button(s)
every 20 minutes since these functions have an
automatic 20 minute time-out function that turns them off.
!
Figure A
Figure B
B
A
C
Air Control
WARNING: RISK OF PERSONAL INJURY!
•
•
To decrease the risk of injury, drowning or entrapment,
never leave your hot tub unattended for any reason while
the cover is open and accessible, especially to small
children and animals!
Precautions should be taken to minimize your exposure
to chemical vapors (that could cause lung, brain, or skin
damage).
11. Turn off power to the spa at the circuit breaker, then drain spa as
outlined in Section 12.2 “Draining And Refilling” (page 36).
12. Fill spa until water covers all jets but does not touch the bottom of
the lowest headrest. DO NOT OVERFILL.
CAUTION: TO DECREASE BUILD UP ON COMPONENTS AND
MINIMIZE ACRYLIC DAMAGE.
Never fill with water from a water softener. If your water is extremely
“hard,” it is preferable to fill half-way with hard water and the rest of
the way with softened water. Water that is too soft can be corrosive
to metal components.
13. Consult your authorized Jacuzzi dealer for chemical
recommendations, then add chemicals to hot tub water to achieve
a constant sanitizer reading within the levels recommended on the
inside cover of this manual.
14. Turn on all jet pumps when adding chemicals to ensure proper
mixing and leave your hot tub cover open until the sanitizer level
becomes stable to protect pillows and plastic knobs from chemical
attack. Refer to the inside cover of the manual.
20
J-200
!
WARNING: RISK OF PERSONAL INJURY.
•
•
To decrease the risk of injury, entrapment or drowning,
never leave your hot tub unattended for any reason,
especially if while the cover is open and accessible to
small children and animals!
To decrease the risk of contracting a waterborne illness
(e.g. an infection, bacteria or virus) and/or respiratory
ailments, maintain water chemistry within 6 step
parameters. If you or other bathers experience such a
condition, discontinue use and seek immediate medical
attention.
15. Establish a sanitizer reading no less than 1.0 ppm free chlorine
or 2.0 ppm bromine, then allow the hot tub to set undisturbed for
8 hours. Retest water after 8 hours to determine if sanitizer levels
are stable. If sanitizer levels are stable, your spa is ready for use.
To ensure healthy water conditions, always maintain a constant
sanitizer reading within the levels recommended on the inside cover
of this manual. If sanitizer levels are not stable at this time, it will be
necessary to repeat this procedure in its entirety (steps 1-15) until
stable sanitizer readings are achieved.
IMPORTANT: If the CLEARRAY® water purification system is removed
from the hot tub or is not operating effectively follow the “without
CLEARRAY®” water chemistry parameters as defined by the Association
of Pool and Spa Professionals.
16. After adequate sanitizer levels are achieved, close all spa air controls
to maximize heat retention when spa is not in use.
21
J-200
9.0
Control Functions
9.1
Control Panel
A. LED Display: Can
display current water
temperature (default
display), water temperature set point,
selected filtration/heating mode, and error
messages.
C
1
D
2
A
E
B
F
G
B. Heat Indicator: Lit when heater is on.
C. Jets 1 Button: Turns jets pump #1 on and off. Press once for low
speed; press a second time for high speed; press a third time to turn
pump off.
D. Jets 2 Button: Turns high-speed jets pump #2 on and off. Press
once to turn pump #2 on; press a second time to turn pump #2 off.
E. Light Button : Turns underwater light (if equipped) and accent lights
on in one of three random modes or one of seven solid colors. Refer
to Section 10.3 (page 26) for details.
F.
Warmer (
G. Cooler (
) Button: Increases water temperature set point.
) Button: Decreases water temperature set point.
Operation Details
• Temperature Adjustment: 65 to 104°F (18 to 40°C). Factory default
setting is 100°F (38°C).
•
LED light system: All LED lights run for 1 hour and then automatically
shut off.
•
Jets 1/Jets 2 Button Operation: Jets run for 20 minutes when
activated, then turn off automatically to conserve energy. Simply
press either jets button to continue operation for an additional 20
minutes.
22
J-200
9.2
General Spa Features and Controls
11
13
14
14
13
3
17
9
6a
4
16
16
14
6b
13
1
1
J-280 model illustrated
1.
2.
3.
4.
5.
6.
•
10
16
7
2
13
15
4
7
3
11
2
7
16
13
11
3
13
2
4
8
5
Control Panel
Headrest Pillows (4 ea.)
Air Controls (4 ea.)
Cup Holders (4 ea.)
Massage Selector (1 ea.)
LED Lighting System:
Underwater light system includes
multi-color footwell light (6a)
• Multiple LED accents lights (6b qty 22 ea.)
7. Suction Fittings (protect massage
selector from debris entrapment/
damage)
8. Waterfall with flow rate control lever
2
3
13
14
13
2
11
4
12
9. Heater Return/Gravity Drain
10. Filter lid with one underlying filter
cartridge (Filter requires periodic
cleaning)
11. Optional audio system speakers
(4 ea.)
12. Optional BLUEWAVE™ Spa Stereo
System
13. Classic Direct Jets (8 ea.)
14. Classic Euro Jets (16 ea.)
15. Classic Mini Jets (6 ea.)
16. Classic Luxury Jets (13 ea.)
17. Classic Whirl Jet (1 ea.)
Specifications Subject to Change Without Notice.
23
J-200
9.3
General Spa Features and Controls (J-235/J-245/J-275)
3
5
12
4
3
12
11
4
16
10
6
2
16
16
8
16
14
16
8
15
14
9
8
8
16
2
16
14
6
6
8
16
12
5
4
7
6
16
3
8
16
1
3
2
2
1
J-275 model illustrated Jet locations and features vary by model.
1. Control Panel
2. Air Controls (3 ea.)
3. Optional audio system speakers
(4 ea.)
4. Headrest Pillows (3 ea.)
5. Classic Direct Jets (8 ea.)
6. Classic Euro Jets (14 ea.)
7. Classic Pulsator Jets (6 ea.)
8. Classic Luxury Jets (12 ea.)
9. Classic Mini Jets (3 ea.)
10. Classic Turbo (2 ea.)
17
11. Waterfall with flow rate control lever
12. Cup Holders (3 ea.)
13. Filter skimmer with one underlying filter cartridge (Filter requires
periodic cleaning)
14. Suction Fittings (3 ea.)
15. Heater Return/Gravity Drain
16. LED lighting system includes multiple LED accents lights (10 ea.)
17. Optional BLUEWAVE™ Spa Stereo
System
Specifications Subject to Change Without Notice.
24
13
J-200
10.0
Operating Instructions
The spa control system has automatic functions that operate upon
start-up and normal operation to protect the system. Upon power up, the
readout displays the following information:
1. Control panel displays current software release then;
2. Control panel displays “888” and all indicator LEDs are lit, permitting visual inspection of all display segments and indicator lights for
proper operation.
3. After the initial start-up sequence ends, the actual water temperature
is displayed. If water temperature at this time is less than the factory default temperature setting of 100°F (38°C) and the spa is set
to either standard filtration/heating mode (Sections 11.1-11.2, page
28), the heater will turn on and run until the water temperature
rises to the factory setting, then turn off.
Note: It is common for the heater to turn on after the spa is first filled
because tap water is often very cold.
10.1
Setting Water Temperature
The spa’s thermostat provides optimum control of water
temperature. The temperature set point (set temperature) can
be adjusted from 65-104°F (18-40°C). To raise
the set temperature, press the WARMER ( )
button. To lower the set temperature, press the
COOLER ( ) button. The first press of either
WARMER ( ) or COOLER ( ) button
displays the set temperature. To access the
C
overtemp feature that allows the spa to reach
106°F (41°C) follow the steps below (Figure 1).
!
B
1
2
A
Figure 1
WARNING: RISK OF HYPERTHERMIA (OVER-HEATING)
CAUSING SEVERE INJURY, BURNS, WELTS OR DEATH!
Water temperature in excess of 104°F (40°C) may injurious to
your health.
A. Press and hold the WARMER (
) button then;
B. Press and hold the JETS 1 (
) button at the same time for 2
seconds. You will see the temperature rise to 106°F (41°C) on the
LED display. To lower the temperature, press the COOLER (
)
button.
C. When the overtemp feature has been activated, the decimal point
after the last digit will flash on and off every second as an indicator
for being in the overtemp mode.
Note: Once the temperature goes below 104°F (40°C) and you would
like to raise the temperature to 106°F (41°C) again, you will have to
repeat the steps above.
1
25
J-200
10.2
Activate Jet Pumps
The control panel JETS 1 button activates jets pump 1. The first press
activates low speed, the second press activates high speed, and the third
press shuts jets pump 1 off. The JETS 2 button activates jets pump 2.
The first press activates high speed, the second press turns jets pump 2
off. When manually activated, either pump will automatically turn off after
20 minutes.
10.3
Multi-Colored LED Light System Operation
The multi-colored LED spa light offers seven constant color
variations and three unique random modes for enhanced spa
enjoyment. Press the Light button once to activate the first
light mode Random Fade, then continue pressing the button
to either turn the light off or to select one of seven constant colors,
random solid color mode or strobe mode as illustrated below.
RANDOM
FADE
OFF
NEAR
WHITE
OFF
LIGHT
BLUE
OFF
VIOLET
OFF
OFF
LIME
GREEN
DARK
BLUE
Spa Light Sequence
OFF
STROBE
RANDOM
SOLID
RED
OFF
DARK
GREEN
OFF
Light Operation Tips:
You must press the light button within 3 seconds of any “off” condition or the
light sequence will revert back to “Random Fade” mode, when reactivated.
Anytime the spa light is manually activated, it will remain on for 1 hour
then automatically shut off.
10.4
Adjusting Individual Jet Flow
The water flow through certain jets in your spa can be
adjusted or turned off by rotating the outside jet ring. Other
jets also offer an adjustable center nozzle that allows you to
change the water discharge angle. Simply tilt the center
Classic Whirl Jet
nozzle in these jets to the desired angle to customize your
personal massage.
Note: Always keep at least 6 adjustable jets open at all times to
ensure proper filtration characteristics within spa.
Classic Pulsator Jet
10.5
Selecting Desired Massage Action
C
For models that incorporate a massage selector valve
(Diverter Jet for J-210, Figure A) that allows you to
B
customize the massage and performance by diverting
A
water between various jet systems within the spa. Simply
A
B
turn valve to positions A, B or C to divert water pressure
to various jet groups.
C
Note: The valve is intended to operate in positions A
Figure A
(Combo), B, or C for optimum performance. It is considered normal for sound levels within the valve to increase between
26
J-200
these positions due to the large amounts of water flowing through it. For
optimum filtration benefits, always leave this valve in position A when the
spa is covered and select positions B or C for maximum jet performance
during spa use.
10.6
Air Controls
Certain jet systems have their own air control. Each control
introduces air into the water lines that supply that specific jet group.
Simply turn the air control of choice counterclockwise to open or
clockwise to close. To minimize heat loss, all air controls should be
closed when the spa is not in use.
10.7
Optional BLUEWAVE™ Spa Stereo System (J-235
to J-280)
Spas equipped with the optional Jacuzzi audio system offer
enhanced enjoyment. These models include an integrated
FM//USB/AUX/Bluetooth receiver with high-quality marine
speakers for unsurpassed sound quality and long-life.
Note: Digital rights management (DRM) files cannot be
played. Personal files (MP3, WMA, iTunes or AAC) can be
played as long as they are not DRM encrypted files.
27
J-200
11.0 Automatic Filtration Cycles
The control system activates a programmable “Standard” or “Economy”
filtration cycle to remove debris from your spa. These cycles use the low
speed jets pump 1 and filter cartridge to quickly clear “skim” the water of
debris and minimize their “bathtub ring” affect while the spa is in use or
during a programmed filter cycle. Apart from their filtration benefit, each
filtration mode also effects the operation of the spa heater.
11.1
Standard Filtration/Heating Modes
Standard filtration/heating modes (F1-F3) are typically selected by
customers in cold climates where heat up times are extended due to
lower ambient temperatures. In these modes, the low-speed pump
and heater will come on as necessary to maintain the set temperature
24 hours a day. The low speed pump will run continuously during the
filtration/heating cycles with the heater coming on as necessary to
maintain the set temperature.
11.2
Economy Filtration/Heating Modes (All Models)
Economy filtration/heating modes (F4-F6) are typically selected by
customers in warm climates where heat up times are minimized due to
higher ambient temperatures. In these modes, the water temperature
is regulated by the set temperature only during a programmed filtration/
heating cycle. The heater will turn on only when there is a heat call
during a programmed filtration/heating cycle.
Note: These modes can be used to conserve energy while on vacation
or out of town for several weeks since heater operation is minimized.
During such times, you can also minimize the spa set temperature to
maximize energy savings!
11.3
Lock Modes - L1-L3 (All Models)
These modes are designed for use during spa service or to prevent
unauthorized use.
11.4
Selecting The Filtration/Heating Mode
Press and hold both control panel WARMER ( ) and COOLER ( )
buttons at the same time, then release. Then press either WARMER
( ) or COOLER ( ) button to select either filtration/heating mode or
lock mode as outlined below.
11.5
Filtration Modes for Spas
During the filtration/heating cycle the Jets pump 1 low speed will activate.
To set a time for the first filtration/heating cycle, simply turn power on to
the spa two minutes prior to the desired time. Example: If you desire your
first filtration/heating cycle to begin at 10:00 AM turn off power to the spa
and turn it back on again at 9:58 AM. You can also press the Warmer,
Cooler and Jets Pump 1 buttons simultaneously for 2 seconds to restart
the spa.
Note: Start time is approximate and may vary slightly from day to day.
28
J-200
With two pump models, an automatic five-minute “blow-out” function also
activates pump 2 for a period of five minutes to flush all lines. Then, after
five minutes, pump 2 turns off and pump 1 continues to operate for the
duration of the cycle.
Note: This function only occurs during the first filtration/heating cycle
each day.
Standard Filtration/Heating Modes (F1-F3)
(Heater automatically turns on during any heat call while in
any Standard mode).
F1 4 hours of filtration/heating per day (one 2-hour cycle
every 12 hours).
F2 6 hours of filtration/heating per day (one 2-hour cycle
every 8 hours).
F3 8 hours of filtration/heating per day (one 2-hour cycle every 6
hours).
Economy Filtration/Heating Modes (F4-F6)
(Heater can only turn on during an active filter cycle while in
any Economy mode).
F4 4 hours of filtration/heating per day (one 2-hour cycle
every 12 hours).
F5 6 hours of filtration/heating per day (one 2-hour cycle
every 8 hours).
F6 8 hours of filtration/heating per day (one 2-hour cycle every 6
hours).
Lock Modes (L1-L3)
(When in a lock mode the display will flash between the
temperature and the Lock mode number)
L1 Lock Out (disables all spa functions to permit filter
cleaning).
Note: The spa should not be left in this lock mode for an
extended period of time. Especially in colder climates or when
freezing conditions exist.
L2 Lock Mode (disables the jets and light buttons to prevent
unauthorized use of spa). Filtration/heating cycle will continue to
operate as programmed in this mode. The temperature display
flashes when this function is enabled. Example: the “F3” filtration/
heating cycle was enabled prior to choosing lock mode. The spa
continues to perform the “F3” cycle until lock mode is canceled,
allowing another cycle to be selected.
L3* Lock Mode (disables the temperature up and down buttons to
prevent unauthorized temperature adjustments). Filtration/heating
cycle will continue to operate as programmed in this mode. The
jets and lights buttons will still continue to operate as normal. The
temperature display flashes when this function is enabled. *Due to
a difference in software this feature is not available for all models.
Note: To exit a Lock Mode you will need to re-enter the filtration/heating
modes and select a cycle from F1-F6.
29
J-200
11.6
Programming the CLEARRAY (Ultraviolet) Water Purification
System
A. Programming the CLEARRAY System (U) or Corona Discharge
Ozone (O3)
Press and hold the Jets pump 1 (
) and Cooler (
) button at the
same time for 3 seconds to enter the sanitizing system program. The
screen will display one of the two menus below:
1
CLEARRAY Menu
O3 Menu
Press
Press
or
or
1. If the LED screen is displaying “U” then pressing the Jets pump
1 will change the sanitizing system from “U” to “O3” and exit the
programming menu. If the LED screen is displaying “O3” then
pressing the Jets pump 1 will change the sanitizing system from “O3”
to “U” and exit the programming menu.
Note: For the O3 option the “=” disables the duration countdown timer.
2. If you do not wish to change the option do not press any buttons and
after 10 seconds the display will return to the main menu.
Note: If the CLEARRAY System has been selected, when the
time allotted has expired (365 days) the display screen will
flash between the water temperature and “blb.” At this time the UV bulb
must be replaced, the quartz tube must be cleaned and the duration
countdown timer needs to be reset.
30
J-200
B. Resetting the duration countdown timer (CLEARRAY® System
only)
Once the duration countdown timer for the CLEARRAY System has
reached zero, you will need to reset it, replace the UV bulb and clean the
quartz tube.
To reset the duration countdown timer:
Press
Press
1
1. Press and hold Jets pump 1 (
) and Cooler (
) at the same
time for 3 seconds.
2. Press the Warmer (
) button until the display shows “0.”
3. If the timer has reached “0,” pressing the Jets pump 1 (
) button
will reset the timer to 365 days. If the timer is not at “0” pressing
the Jets pump 1 button will not reset it.
Note: If the spa power is interrupted, the duration countdown timer is not
affected. The number of days remaining is stored in the memory and will
continue to countdown once power is regained.
4. If the duration countdown timer is not at “0” and you need to reset it:
a. Press and hold the Jets pump 1 and Cooler buttons at the same
time for 3 seconds.
b. Press the Warmer button to scroll to “U.”
c. Press the Jets pump 1 button to switch from “U” to “O3.”
d. Press and hold the Jets pump 1 and Cooler buttons at the same
time for 3 seconds.
e. Press the Warmer button to scroll to “O3.”
f. Press the Jets pump 1 button to switch from “O3” to “U.” The
timer has been reset to 365 days.
1
1
31
J-200
12.0 Spa Maintenance
Proper and regular maintenance of your spa will help it retain its beauty
and performance. Your authorized Jacuzzi dealer can supply you with
all the information, supplies, and accessory products you will need to
accomplish this.
!
•
•
•
•
•
•
DANGER: RISK OF SEVERE INJURY OR DROWNING BY
ENTRAPMENT!
Keep hair, loose articles of clothing or hanging jewelry away from
suction fittings, rotating jets or other moving components to avoid
entrapment that could lead to drowning or severe injury.
Never use the spa unless all suction guards, filter, filter lid, or
skimmer assembly are installed to prevent body and/or hair
entrapment.
Never operate or use the spa if the filter, filter lid, or skimmer
assembly are broken or any part of the skimmer assembly is
missing. Please contact your dealer or nearest service center for
service.
The suction fittings and suction covers in this spa are sized
to match the specific water flow created by the pump(s). If it
is necessary to replace the suction fittings, suction covers or
pump(s), be sure that the flow rates are compatible and are in
compliance with the VGB Safety Act, page 2.
Never replace a suction fitting or suction cover with one rated less
than the flow rate marked on the original suction fitting. Using
improper suction fittings or suction covers can create a body or
hair suction entrapment hazard that may lead to drowning or
severe injury.
Owners must alert all spa users to the potential risk of Hair,
Limb, Body, Evisceration (disembowelment), and Mechanical
Entrapment, page 6.
12.1
Cleaning The Filters
TO DECREASE DROWNING OR ENTRAPMENT, ALWAYS TURN
POWER TO SPA OFF BEFORE CLEANING THE FILTER CARTRIDGE!
J-210/J-235/J-245/J-275 Models:
These model spas are equipped with a skimmer basket and filter
cartridge located in the skimmer/filter well. Filtering is accomplished
when jets pump #1 turns on in low speed initiating water flow through
the skimmer basket and polyester mesh filter cartridge. As this happens,
suspended particles become trapped on the filter’s surface.
To Clean Filter:
1. Turn off power to the spa at the home’s breaker panel or select the
L1 “Lock Out” mode (page 28) to disable all spa functions.
2. Remove the filter strainer lid assembly by rotating it
counterclockwise, Figure A (page 33).
32
J-200
3. Remove the filter cartridge by rotating it counterclockwise to
unthread it from the filter wall fitting (Figure B). Then lift it straight up
to remove from filter well (Figure C).
4. Using a garden hose with a high-pressure nozzle, rinse debris from
the filter pleats beginning at the top and working your way downward
(Figure D). Continue, one section at a time, until you have rinsed all
of the filter’s pleats.
Figure A
Figure B
SPA SHELL
SPA SHELL
Figure C
Figure D
SPA SHELL
CARTRIDGE
To ensure optimum performance, clean skimmer basket and filter
cartridge once a month or as necessary, depending on use.
J-210 models include filters on their footwell suction covers
(shown right) that prevent debris from entering the pump when
operating. These filters must remain in place to protect the
components from debris entrapment/damage. They should be
cleaned every 2 months, or when weak pump performance is
observed.
33
J-200
J-280 Models:
These model spas are equipped with a skimmer bag and one high
performance pleated filter cartridge located under the filter cover.
Debris are filtered by drawing water through the skimmer bag and filter
cartridge when jets pump 1 is running a programmed filter cycle or when
manually activated by spa use. Combined, both provide unsurpassed
water quality by trapping surface oils and suspended particles. The filter
cartridge should be cleaned once a month, or as needed for optimum
performance.
J-280 Models:
Refer to steps below for complete filter cleaning/replacement
instructions.
A
DANGER: TURN POWER TO SPA OFF! TO DECREASE
RISK OF DEATH, DROWNING, OR ENTRAPMENT,
NEVER OPERATE SPA WHEN FILTER IS NOT PROPERLY
INSTALLED OR IF SKIMMER ASSEMBLY IS DAMAGED OR
ALTERED!
(Inside Spa View)
(Inside Spa
View)
B
34
Lift upward on filter
skimmer cover handles
to remove it from
mating retainer clips.
(Filter Cover Back View)
C
Remove skimmer bag
from clips, then clean
out debris.
D
Rotate filter
cartridge handle
counterclockwise to
unthread filter cartridge
from mating wall fitting.
J-200
C
ar
tr
id
ge
Trapped
Air
Bubbles
E
Lift unthreaded filter
cartridge from skimmer
well.
F
Rinse debris from filter
cartridge pleats using
a garden hose and
high-pressure nozzle.
Start at the top and
work downward to the
handle. Repeat until all
pleats are clean.
G Submerge filter
cartridge in spa. Tilt
threaded end upward
to remove trapped air
bubbles, then keep
cartridge submerged to
prevent air entrapment
during installation
(step H).
(Inside Spa View)
(Inside Spa View)
(Filter Cover Back View)
H
Install filter cartridge
back onto wall
fitting by rotating
the cartridge handle
clockwise. DO NOT
OVERTIGHTEN!
I
Install clean skimmer
bag back onto the filter
cover clips as shown.
J
Install filter cover by
sliding it down into
position over mating
spa retainer clips. Turn
spa power back on
after skimmer cover is
installed.
Periodically, the filter cartridge will need a more thorough cleaning to
remove imbedded oils and minerals. For this, we suggest cleaning as
illustrated followed by soaking the filter overnight in a plastic container
filled with a solution of water and specially formulated filter cleanser
available from your authorized Jacuzzi dealer. The average life
expectancy of each filter is approximately two years with proper care and
water quality maintenance. Replacement cartridges may be purchased
from your authorized Jacuzzi dealer.
35
J-200
12.2
Draining and Refilling
About every 3 months, you will want to replace the spa’s water. The
frequency depends on a number of variables including the amount of
use, attention paid to water quality maintenance, etc. You will know it is
time for a change when you cannot control sudsing and/or you can no
longer get the normal feel or sparkle to the water even though the key
water balance measurements are all within the proper parameters.
CAUTION! READ THIS BEFORE DRAINING: To prevent damage
to the spa’s components, turn off power to the spa at the circuit
breaker before draining it. Do not turn the power back on until
your spa has been refilled.
CAUTION: There are certain precautions to keep in mind when
draining your spa. If it is extremely cold, and the spa is outdoors,
freezing could occur in the lines or the equipment, see “WINTERIZING” (page 38). On the other hand, if it is hot outdoors, do not
leave the spa’s surface exposed to direct sunlight.
To drain your spa, perform the following steps (actual
drain may vary from one shown). Turn off power to
spa at breaker.
1. Locate and remove the synthetic cabinet door
screws and door. The door is located directly
below the control panel.
2. Cut zip tie(s) and pull drain hose from
equipment area (Figure A).
3. Hold drain hose above water line, then
unthread drain cap (1) from hose using a
counterclockwise rotation (Figure B). Place
drain hose on ground to start drain, making sure
to direct water away from spa. If equipped, turn
valve (2) counterclockwise to open the valve
(Figure C).
4. After spa is drained, reinstall drain cap on drain
hose fitting until finger tight! If equipped, turn
valve (2) clockwise to close the valve. DO NOT
OVERTIGHTEN!
5. Coil drain hose up and place back inside the
spa equipment bay (Fig. A).
6. Reinstall synthetic cabinet door and screws, then
refer to the “Spa Fill Up Procedure” (page 17).
Figure A
2
1
Figure B
Figure C
Drain location
and appearance
may vary.
12.3
Pillow Care
Remove and clean each headrest by gently grasping both ends in each
hand and pulling upward to release each pillow “snap.” To reinstall,
simply “snap” each pillow back into place. Clean as needed with soapy
water using a cloth or soft-bristle brush. Always remove the pillows when
adding chemical shock treatment to the spa water. The pillows can be
36
J-200
returned to the spa when the sanitizer reading is stable as recommended
on the inside cover of the manual.
12.4
Cleaning The Spa Interior
To preserve the sheen of your spa’s surface, it is crucial that you avoid
using abrasive cleaners or cleaners which have adverse chemical effect
on the surface. If you are not certain as to the suitability of a particular
cleanser, consult your authorized Jacuzzi dealer. Regardless of the
cleanser used, use extreme care to assure that no soap residue is left on
the surface. This could cause severe sudsing when the spa is refilled.
12.5
Vinyl Cover Care and Maintenance
Your Jacuzzi cover has a vinyl encasement. This vinyl encasement is
attractive and durable. Monthly cleaning and conditioning is strongly
recommended to maintain and increase the longevity of your cover.
A. To Clean and Condition the Vinyl Cover
1. Use a garden hose to loosen debris and dirt.
2. Using a large sponge or a soft bristle brush, use diluted or mild soap
and scrub the vinyl top. Rinse clean and do not allow soap to dry on
cover. Do not use soap on the underside of the cover.
3. Please check with your Jacuzzi Dealer for recommended cover
care and conditioning products. Condition using non-petroleum
based conditioners to keep the vinyl supple and threads/stitching
from drying out. Do not use solvents, abrasive cleaners or strong
detergents. Do not use products that contain silicone or alcohol.
B. Additional Care and Maintenance Instructions:
1. Debris can accumulate on the spa cover. Removal of snow or other
debris will help to avoid breakage of the foam cores.
2. Be sure to lock the cover straps to secure the cover from unwanted
or accidental entry.
3. Do not place heavy objects on the vinyl.
4. Do not walk, sit or stand on the cover.
5. Do not drag or use the flaps/skirt or the cover lock straps to remove
the cover.
6. Use only recommended cover lift systems.
7. Use only chemicals and cleaners recommended by Jacuzzi.
8. Remember to keep spa covered when not in use. Maintaining proper
water levels assures efficient operation and efficient electrical usage.
9. Do not expose your spa to the sun for extended periods of time as
UV rays can damage the interior surface.
10. Use caution when removing cover. Before removing cover, assure all
locks have been released to avoid lock breakage and or cover strap
damage.
12.6
Maintaining The Synthetic Cabinet
Your new spa’s synthetic cabinet requires little or no maintenance of
any kind. To clean, simply wipe cabinet with a clean towel and mild soap
solution.
37
J-200
CAUTION: Never spray cabinet with a garden hose for any
reason since this action may induce an electrical short in the
spa’s electrical equipment.
12.7
Winterizing
Your Jacuzzi spa is designed to automatically protect itself against
freezing when operating properly. During periods of severe freezing
temperatures, you should check periodically to be certain that the
electrical supply to the spa has not been interrupted. In extreme, bitter
cold weather less than 32°F (0°C), choose the F3 “Standard” filtration/
heating mode to prevent freezing (page 28). If you do not intend to
use your spa, or if there is a prolonged power outage during periods
of severe freezing temperatures, it is important that all water be
removed from the spa and equipment to protect against damage
from freezing.
Expert winterization of your spa is highly recommended, contact
your authorized Jacuzzi dealer. In emergency situations, damage can
be minimized by taking the following steps:
CAUTION: TURN OFF POWER TO HOT TUB!
Follow the directions on page 36 for draining the spa.
1. Turn off power to the spa.
2. As the water level drops below the seats, use whatever means
necessary to get the water out of the recessed seating areas and
into the footwell, such as a wet/dry vacuum.
3. Turn the massage/diverter selector(s) into the middle combo position
to allow the water in the plumbing lines to drain, see page 26.
4. Turn the waterfall valve to the open position to allow the water in the
plumbing lines to drain, see page 23 and 24.
5. Open all the air controls and leave them open until you resume use
of the spa, page 27.
6. As the water level drops below the seats, use whatever means
necessary to get the water out of the recessed seating areas and
into the footwell, such as a wet/dry vacuum.
7. When the water level ceases to drop, use whatever means available
to remove any remaining water from the footwell, such as a wet/dry
vacuum.
8. Remove the synthetic cabinet panel under the control panel and
locate the drain plugs on the front of the pump(s), (Figure A, page
15). Remove plugs to allow water to drain out of pumps and
heater.
Note: Approximately one to two gallons will be released during this
procedure. Use a wet/dry vacuum or other means to keep this from
flooding the equipment compartment. Replace the drain plugs.
9. Loosen hose clamp at bottom of CLEARRAY® system and pull hose
off of CLEARRAY fitting (twist the hose back and forth while pulling
downward). Tip hose down and allow to drain. Then reinstall hose
38
J-200
and clamp. Remove the cover of the CLEARRAY system to access
the UV bulb and quartz tube. Remove and store the UV bulb in a
safe location. Remove and dry off the quartz tube then reinstall it.
Depending on the length of time, consider replacing the UV bulb
when you resume use of your hot tub.
10. Re-install synthetic cabinet side panel and cover spa so that no
casual moisture can enter into it.
Consult your authorized Jacuzzi dealer if you have any questions
regarding winter use or winterizing.
12.8
Restarting Your Spa in Cold Weather
If you want to start up your spa after it has sat empty for a time in
freezing temperatures, be aware that the water remaining in certain
sections of the piping may still be frozen. This situation will block water
flow preventing the spa from operating properly and possibly damaging
the equipment. We recommend you consult your authorized Jacuzzi
dealer for guidance before attempting to re-start your spa under these
conditions.
13.0
Water Quality Maintenance
To decrease the risk of contracting a waterborne illness (e.g. an infection,
bacteria or virus) and/or respiratory ailments, maintain water quality
within specified limits. This will enhance your enjoyment and prolong
the life of the hot tub’s equipment. Doing so requires regular attention
because the water chemistry involved is a balance of several factors.
Procrastination in regard to water maintenance will result in poor and
potentially unhealthful conditions for soaking and even damage to your
hot tub investment. For specific guidance on maintaining water quality,
consult your Authorized Jacuzzi dealer who can recommend appropriate
chemical products for sanitizing and maintaining your hot tub.
!
WARNING: FAILURE TO MAINTAIN WATER QUALITY
CAN RESULT IN:
• Increase risk of contracting a waterborne illness (e.g. an
infection bacteria or virus) and/or respiratory ailments.
• Damage the equipment, components and spa shell, which
are not covered under the hot tub’s warranty.
CAUTION: Never store hot tub chemicals inside the hot tub’s
equipment bay. The equipment bay may reach elevated temperatures, this is where high voltage electronic devices are located. This
area is not intended for storage of any kind.
39
J-200
13.1
pH Control
pH is a measure of relative acidity or alkalinity of water and is measured
on a scale of 0 to 14. The midpoint of 7 is said to be neutral, above which
is alkaline and below which is acidic. In spa water, it is very important
to maintain a slightly alkaline condition of 7.4 to 7.6. Problems become
proportionately severe the further outside of this range the water gets.
A low pH will be corrosive to metals in the spa equipment. A high pH will
cause minerals to deposit on the interior surface (scaling).
In addition, the ability of the sanitation agents to keep the spa clean is
severely affected as the pH moves beyond the ideal range. That is why
almost all spa water test kits contain a measure for pH as well as the
sanitizer.
13.2
Sanitizing
To destroy bacteria and organic compounds in the spa water, a sanitizer
must be used regularly. Chlorine and bromine are the two most popular
sanitizers used to date. Many other additives are available for your spa.
Some are necessary to compensate for out-of-balance water, some aid
in cosmetic water treatment and others simply alter the feel or smell of
the water. Your authorized Jacuzzi dealer can advise you on the use of
these additives. When adding spa shock (chlorine or non-chlorine) or pH
balancing chemicals activate the jets pump(s) and leave the spa cover
open for a minimum of 20 minutes. By doing this you will allow excessive
chemical vapors to exit the spa, protecting pillows and plastic knobs from
chemical attack.
!
WARNING: RISK OF PERSONAL INJURY, DROWNING
OR ENTRAPMENT!
Never leave your hot tub unattended for any reason while the
cover is open and accessible, especially to small children and
animals!
CAUTION: RISK OF PERSONAL INJURY OR SPA DAMAGE!
Never add chlorine tablets (trichlor) or acid to your hot tub
for any reason! These chemicals may damage components
within your hot tub, burn or irritate your skin, create a rash
and void the manufacturer warranty for your spa.
40
J-200
13.3
CLEARRAY® Water Purification System
CLEARRAY Water Purification System is exclusive
technology utilizing natural ultraviolet technology to
eliminate waterborne bacteria, viruses, and algae in
portable spas. The ultraviolet light otherwise known as
UV-C or germicidal light inactivates the microorganisms
disrupting the DNA so that it cannot reproduce and is
considered lifeless. CLEARRAY is plumbed in-line with your
filtration system. After the water is drawn from the pump, filter,
and heater it is then directed though the CLEARRAY system.
Water passes through an ultraviolet light energy that treats and
disinfects the water. The water is then pumped back into the
spa giving you crystal clear water instantly. The system has a
ballast that is the power supply for the purification system; it has two LED
indicator lights the green indicating incoming power and the red
indicating the system is properly working. CLEARRAY is standard for all
models.
Note: The CLEARRAY System only runs when the jets pump 1 is
running.
WARNING!
DO NOT LOOK AT LIT BULB
SEVERE EYE DAMAGE
OR BLINDNESS CAN OCCUR
120 - 230V
After a year the bulb must be replaced. If the UV timer has been
programmed correctly a message will appear on the LED display when
the time allotted has expired. In order to clear the “blb” message a new
UV bulb needs to be installed and the timer must be reset (Section 11.6,
page 31).
Note: In order to access the CLEARRAY unit, the front synthetic panel or
the stereo panel and the right corner panel need to be removed.
41
J-200
13.4
CLEARRAY® Lamp Replacement and Quartz Tube
Maintenance
Important: It is MANDATORY that the UV bulb is replaced and the
quartz tube be cleaned every 12 months to maintain optimum
performance.
9 10
1
2
6 7
4
3 13
8
5
11
Figure 1
12
!
DANGER:
!
WARNING: DRAIN THE SPA IF YOU ARE REPLACING OR
!
WARNING: ALLOW LAMP TO COOL DOWN PRIOR TO
!
DANGER:
POSITION!
TURN THE SPA BREAKER TO THE OFF
CLEANING THE QUARTZ TUBE!
REMOVING FROM QUARTZ TUBE.
NEVER LOOK AT THE LIT BULB. THIS CAN
CAUSE SEVERE EYE DAMAGE OR BLINDNESS.
UV BULB REPLACEMENT AND QUARTZ TUBE MAINTENANCE:
Note: Location of CLEARRAY System and connection may vary by
model.
1. Turn the breaker to the spa OFF. DRAIN YOUR
SPA. Disconnect the CLEARRAY System from the
controller, Figure 2.
Note: If you are only replacing the UV bulb then the spa
does not have to be drained. You will need to drain it if
you are replacing or cleaning the quartz tube.
!
Connection
UV Unit
WARNING!
DONOT LOOK AT LIT BULB
SEVERE EYE DAMAGE
OR BLINDNESS CAN OCCUR
SPA CONTROLLER
Figure 2
DANGER: NEVER REMOVE COVER WITHOUT FIRST
TURNING OFF AT POWER SOURCE AND DRAINING THE
SPA .
2. Once the UV bulb has cooled off remove the CLEARRAY System
enclosure cover (10) and gasket (9) by removing the four screws
(11).
42
J-200
Figure 3
7
Figure 4
Figure 5
4
8
4
5
3. Remove the black bulb boot (8) by sliding it over the cable away from
the quartz seal compression nut (7), Figure 3.
4. Slowly remove the UV bulb (4) out of the quartz tube.
5. Remove bulb socket (5) from the UV bulb (4), Figure 4.
6. Remove the quartz seal compression nut (7) by turning it
counterclockwise, Figure 3. Use a pair of channel-lock pliers if
needed, Figure 5. You will notice that there is a
2
stainless steel compression washer (6) that slides
13
over the quartz tube. Save the washer (6) for later
use, Figure 6. There is also a black seal ring (13),
7
6
grasp the black seal ring; slowly and carefully
remove the quartz tube.
Figure 6
7. Now you are ready to clean or replace the quartz tube (2).
For the cleaning of the quartz tube (2), follow steps 8 and 9 then
proceed to step 10. For replacing of the quartz tube (2), skip steps 8
and 9 and proceed to step 10.
8. Cleaning quartz tube: Clean the quartz tube by wiping until clear
using a paper towel or a dry cotton cloth. If needed a household tub
and shower lime removal product can be used.
!
WARNING: Do not use abrasive cleaners as they can
scratch the quartz tube surface.
9. Rinse the quartz tube with clean water to completely remove any
cleaning products that were used in step 4.
10. Replacing quartz tube: You will notice that the new quartz tube
does not have a black cushion on the domed end as the old quartz
tube does. This is normal as the cushion was provided with the
original quartz tube to protect it from breakage during transportation.
Install the black seal ring (13) over the opened end of the quartz
tube. Place the new quartz tube (2) into the water chamber (1) with
the domed end first making sure it is inserted and seated inside the
quartz end holder. Only a small portion will be exposed when it is
seated correctly.
11. Reinstall the compression washer (6) over the open end of the quartz
tube (2). Push it against the quartz black seal ring (13).
12. Reinstall and hand tighten the quartz seal compression nut (7) by
turning it clockwise.
13. Refill your spa.
43
J-200
14. System Test 1: Assure there is no water dripping from the seal
compression nut (7). If water is visible, STOP and tighten the
compression nut (7) using a pair of channel lock pliers to a maximum
of 1/4 turn. If that does not fix the leak, then repeat quartz tube
maintenance process from step 1 through step 13. Make sure there
is no water leaking before proceeding to step 15.
15. System Test 2: Reconnect the CLEARRAY System to the controller.
Turn breaker back ON. Turn on the pump to circulate the water
through the CLEARRAY System. Wait for 5 minutes and assure no
water is dripping. If water is visible, STOP, fix the leak by repeating
quartz tube maintenance process from step 1 through step 14. Make
sure there is no water visible and turn the pump and breaker
OFF, disconnect the CLEARRAY System to the controller
BEFORE proceeding to step 16.
16. Reconnect the bulb socket (5) to the new UV bulb (4) make sure you
use the latex glove provided when handling the UV bulb.
Note: Align pins on UV bulb (4) to the receptacle holes on the bulb
socket (5) before inserting the pins completely into socket holes. Failure
to do so will damage the UV bulb.
!
WARNING: DO NOT TOUCH THE NEW UV LAMP WITH
YOUR BARE HAND. Oil on your skin will cause hot spot on
the UV bulb and shorten the life of your UV bulb. Use the
provided latex glove to handle the UV bulb.
17. Slide the new UV bulb (4) back inside the quartz tube, Figure 3.
18. Reinstall the black bulb boot (8) back over the quartz seal
compression nut (7).
19. Reinstall the enclosure cover (10) with gasket (9) and secure with
the screws.
20. Reconnect the CLEARRAY System to the controller and turn on the
power to the spa.
21. Properly dispose of the old UV bulb.
!
WARNING: This CLEARRAY System includes a UV bulb,
which contains mercury. Dispose of the bulb in accordance
with disposal laws. See www.lamprecycle.org.
22. Once power is activated you can check the ballast
(12), Figure 7, to see if the CLEARRAY System
is functioning. A solid green light indicates that the
CLEARRAY System is being provided power and
should always be on. A solid red light indicates that
UV bulb is activated.
44
Indicator
Lights
120 - 230V
Figure 7
J-200
14.0
Error Conditions/Error Messages
Your spa has a self-diagnostic control system. The system will
automatically display the following if a problem is detected. Always
insist on genuine Jacuzzi replacement parts.
14.1
Panel Displays COL
Cool Condition - Temperature has dropped 20°F (11°C)
below the current set temperature. Jets pump 1 and the
heater have been activated to bring the temperature to within 15°F (8°C)
of the set temperature. No corrective action is required!
Note: This condition is common during first time fill ups or during refills
since tap water is often very cold. “COL” will only appear when the spa is
in Economy mode.
14.2
Panel Displays ICE
Freeze Protection - A potential freeze condition has been
detected. No action is required. Jets pump and heater will
operate to circulate and warm water through the plumbing until spa is out
of DANGER. See “Winterizing” (page 38).
Note: “ICE” will only appear when the spa is in Economy mode.
14.3
Panel Displays SN1
Open sensor (heater is disabled) or shorted sensor (spa is
deactivated). The high-limit temperature sensor is not
functioning. Contact your authorized Jacuzzi dealer or qualified service
technician.
14.4
Panel Displays SN2
Open or shorted sensor (heater disabled). The temperature
sensor is not functioning. Contact your authorized Jacuzzi
dealer or qualified service technician.
14.5
Panel Flashes FL1 or FL2
A flashing “FL1” display means the pressure switch is
not closed when the jets pump 1 is activated. Proper water
flow is inhibited or the pressure switch has malfunctioned. A
flashing “FL2” display means the pressure switch is malfunctioning
closed. In either case, the heater is deactivated. To correct condition,
perform to the following:
1. Verify water level is one inch below lowest pillow. Add water if
necessary.
2. Check for clogged or dirty filter cartridge (Sec. 12.1, page 32).
3. Purge “air lock” from jets pump 1 by loosening the upper pump head
drain screw (Figure A, page 15) for a few seconds to release
trapped air, then retighten drain screw. FINGER TIGHT ONLY!
4. If problem persists, contact your authorized Jacuzzi dealer.
45
J-200
14.6
!
Panel Displays OH
WARNING: RISK OF HYPERTHERMIA (OVER-HEATING)
CAUSING SEVERE INJURY, BURNS, OR WELTS.
Water temperature is above acceptable limits. DO NOT
ENTER SPA! Water temperature has reached 112°F (44°C)
and the low speed jets pump 1 has activated to circulate
water through heater. Contact your authorized Jacuzzi dealer or qualified
service technician.
14.7
!
Panel Displays (- - -)
WARNING: RISK OF HYPERTHERMIA (OVER-HEATING)
CAUSING SEVERE INJURY, BURNS, OR WELTS.
Water temperature is above acceptable limits. DO NOT
ENTER SPA! The safety “Watchdog” software has been
triggered and the spa is deactivated. A problem has been
detected which could cause damage to the spa or its
components. Contact your authorized Jacuzzi dealer or qualified service
technician.
14.8
Panel Displays BLB
UV bulb needs to be replaced. The message will flash
between “blb” and the water temperature. The countdown
timer for the UV bulb needs to be reset (Section 11.6, page 31).
A new UV bulb can be purchased from a local Jacuzzi dealer.
15.0
Troubleshooting Procedures
In the event your Jacuzzi spa is not working the way it should, please
first review all the installation and operating instructions in this manual
and check the message on the panel display. If you are still not satisfied
it is working properly, please follow the appropriate troubleshooting
instructions below.
Note: If any of the supply cords to the accessories are damaged,
they must be replaced by authorized service personnel. Contact your
authorized Jacuzzi dealer or qualified service technician. Always insist
on genuine Jacuzzi replacement parts.
15.1
None of the Components Operate (e.g. Pump, Light)
Check the following:
1. Is there power to the spa?
2. Is the household circuit breaker tripped?
3. Contact your authorized Jacuzzi dealer or qualified service
technician.
46
J-200
15.2
Pump Does Not Operate But Light Does
Press the JETS 1 button:
1. If no water movement is detected, make sure power is going to
the spa and check the water level. If it does not solve the problem,
contact your authorized Jacuzzi dealer or qualified service
technician.
2. The main jets pump 1 operates but no water flows to jets. Check the
following:
• Jets may all be closed in spa. Verify all jets are in the open “on”
position (Sec. 10.4, page 26).
• Pump may not be properly primed. This can happen after the spa is
drained and refilled. Press the JETS 1 button on the control panel
several times, never leaving the motor running for more than 5 to 10
seconds at a time. Turn power off and let the air out of spa plumbing
system by removing the filter cartridge (Sec. 12.1, page 32). Make
certain you reinstall the filter cartridge before turning on spa power
and restarting the jets pump 1.
15.3
Poor Jet Action
1. Make sure jets are in the full open “on” position (page 26).
2. Press the JETS 1 button to make certain pump #1 is on.
3. Open all air controls to their full on position (counterclockwise).
4. Check for dirty filter. Clean, if necessary (Section 12.1, page 32).
15.4
Water is Too Hot
Reduce thermostat setting.
15.5
No Heat
1. Check thermostat setting.
2. Keep the spa cover in place while heating.
3. Check the settings to see if your spa is in economy filtration/heating
mode (page 28).
Should checking the above steps fail to correct the problem, please call
your dealer so that they may arrange service. We build the best spas in
the industry. Nonetheless, we are always striving to improve the quality
and features of our products.
Your input as a Jacuzzi spa owner is a cherished part of this process. If
you have any comments or suggestions, or if you wish to be informed on
any new products for your spa, please write to us.
CONGRATULATIONS on your good taste and welcome to the happiest
and most relaxed family in the world!
47
48
DANGER
Turn power off
before servicing. This
task should only be
performed by a qualified technician.
RISK OF SHOCK OR
ELECTROCUTION!
!
7
8
9
10
2
3
4
5
EXP BAR
POWER
6
1
Mini-Din Control
Panel Cable
Ports 1-10
power spa
lights, waterfall
lights and step
lights on
applicable
models
HI
HI
LO
C
(Not offered on
all models)
Pump 2
Pump 1
Circ
Pump
OR
LED Lighting
System DCU
MAIN POWER
ON//OFF SHUTOFF
SWITCH
EXTERNAL SERVICE PANEL
BOX DISCONNECT MEANS
MUST BE LOCATED NO CLOSER
THAN 5 FT. (1.52m) FROM THE
INSIDE WALLS OF THE SPA AND
WITHIN SIGHT OF SPA
(Not offered
on all models)
CLEARRAY
Mini-Din Cable provides
constant 12 VAC from
yellow transformer wires
EXP BAR
Light DCU
WHT
BLK
RED
BLK
WHT
BLK
WHT
BLK
WHT
GRN
1
K6
K5
K4
K3
K2
K1
2
J7
BLK
K7
J8
Stereo
(Not offered on all models)
RED
Power Supply
F1
J4
K8
BLK
J10
J3
7
5
3
1
JP1
8
6
4
2
J2
RED
J9
J1
Control Panel
Heater
5.5 kW
240 VAC
This device complies with Part 15 of the
FCC rules. Operation is subject to the
following two conditions:
1. This device may not cause harmful
interference.
2. This device must accept any inteference
received including interference that may
cause undesired operation.
Flow sensor
Hi - limit / freeze sensor
Temperature sensor
Logic Jumper Settings
JP1 1-2 ON = 40A Logic
JP1 1-2 OFF = 50A Logic (Factory Default Setting)
JP1 3-4 ON = 2 Pump Operation
JP1 3-4 OFF = 1 Pump Operation
JP1 5-6 ON = 60A Logic (Remove JP1 1-2 Jumper)
JP1 5-6 OFF = Leave Off for 40A or 50A Logic
JP1 7-8 ON = Celsius Temperature Display
JP1 7-8 OFF = Fahrenheit Temperature Display
Standard 240 VAC, 3-Wire Connection (60 Hz, 1-Phase Service)
USE COPPER CONDUCTORS ONLY. WIRE SIZE MUST BE APPROPRIATE
PER NEC AND/OR LOCAL CODES. THE MAX SUPPLY CONNECTOR
AMPACITY IS 60A. THE AMPERE RATING OF SUPPLY CONDUCTOR
OVERCURRENT PROTECTIVE DEVICE IS 60A.
F1
30A, 250V
SC-30
BLK
J5
RED BLK
TB1
RED
J6
J19
J18
J17
J16
J15
J14
J13
J12
J11
J21
J20
Transformer
240 VAC
J-200
16.0 Circuit Board Diagrams
16.1
North American J-235, J-245, J-275 and J-280 Models
This wiring diagram is used for the 240V 60 Hz North American spa
models.
J-200
16.2
North American J-210 Convertible Models
This wiring diagram is used for all J-210 120/240V 60 Hz North American
convertible spa models.
!
DANGER
RISK OF SHOCK OR
ELECTROCUTION!
Light DCU
1
6
2
7
3
8
4
9
5
10
EXP BAR
POWER
Ports 1-10
power spa
lights, waterfall
lights and step
lights on
applicable
models
Turn power off
before servicing. This
task should only be
performed by a qualified technician.
Mini-Din Control
Panel Cable
EXP BAR
Mini-Din Cable provides
constant 12 VAC from
yellow transformer wires
Transformer
120 VAC
Control
Panel
OR
LED Lighting
System DCU
J20
J21
8
6
4
2
J1
7
5
3
1
Temperature Sensor
J2
BLK J12
CLEARRAY
J1 Logic
Logic Jumper
Jumper Settings
Settings
J1
JP1 1-2
1-2 ON
ON =
= 30A
30A Logic
Logic (4-wire
(4-wire 120/240
120/240 VAC
VAC operation
operation only)
only)
JP1
JP1 1-2
1-2 OFF
OFF =
= 40A
40A Logic
Logic (4-wire
(4-wire 120/240
120/240 VAC
VAC operation
operation only)
only)
JP1
JP1 7-8
7-8 ON
ON =
= °C
°C Temperature
Temperature Display
Display
JP1
JP1 7-8
7-8 OFF
OFF =
= °F
°F Temperature
Temperature Display
Display
JP1
J3
J14
Hi-limit/Freeze Sensor
Pressure Switch
BLK J16
Circ.
Pump
(not offered
on all models)
C
WHT
F1
J11
J15
WHT
K8
Heater IN
J17
WHT
HI
RED
Heater OUT
J9
J8
RED BLK
Main Pump
LO
J7
J10
RED BLK
THERM
THERM
SWITCH
SWITCH
This device complies with Part 15 of the
FCC rules. Operation is subject to the
following two conditions:
1. This device may not cause harmful
interference.
2. This device must accept any inteference
received including interference that may
cause undesired operation.
(Located inside the heater for certain models)
Heater
1.0 kW @ 120 VAC (3-wire connection)
4.0 kW @ 240 VAC (4-wire connection)
WHT
TB1
BLK
K7
J5
WHT
BLK
GRN
WHT
J13
J6
BLK
GROUND
Plug-in
GFCI
Cord (US
Models
Only) OR
Hard
Wire
F1
20A
250V
SC-20
K5
1
2
3
RED*
BLK
Standard 120 VAC 3-Wire Connection (60 Hz, 1 Phase, 15A Service),
USE COPPER CONDUCTORS ONLY. WIRE SIZE MUST MEET NEC RECOMENDATIONS
AND/OR LOCAL CODES AND IS DETERMINED BY MAXIMUM CURRENT DRAW AND
LENGTH OF RUN.
Hard
Wire
Only
GROUND
WARNING, ELECTRICAL SHOCK HAZARD EXISTS! Always remove power to spa before wiring and/or configuring the circuit board
To circuit board
GRN
TB1 WHT
WHT
1
BLK
2
RED
3
RED*
BLK
RED*
Optional 4-Wire 240/120 VAC Convertible Heater Connection
1. Remove and discard the factory installed GFCI Cord.
2. Move RED* wire from TB1 position #1 to TB1 position #3 as shown below.
3. Permanently connect to the power supply. Use copper conductors ONLY. Wire size must be
appropriate per NEC and/or local codes.
4. If hot tub is to be operated on 30A service, make sure the jumper provided at location JP1 #1 & 2
on the circuit board is installed. If hot tub is to be operated on 40A service, remove the jumper
JP1 #1 & 2 on the circuit board.
EXTERNAL SERVICE PANEL
BOX DISCONNECT MEANS
MUST BE LOCATED NO CLOSER
THAN 5 FT. (1.52m) FROM THE
INSIDE WALLS OF THE SPA AND
WITHIN SIGHT OF SPA
MAIN POWER
ON//OFF SHUTOFF
SWITCH
49
50
DANGER
Turn power off
before servicing. This
task should only be
performed by a qualified technician.
RISK OF SHOCK OR
ELECTROCUTION!
!
7
8
9
10
2
3
4
5
EXP BAR
LED Lighting
System DCU
OR
EXP BAR
POWER
6
1
Light DCU
Pump 2
Pump 1
HI
HI
LO
Circ.
Pump
C
BRN
BLU
TB2
J11
J21
J20
1
K6
K5
K4
K3
K2
K1
2
J7
J8
BRN
K7
Stereo
(not offered on all models)
BLU
Power Supply
F1
J4
K8
BRN
J10
J3
7
5
3
1
JP1
8
6
4
2
J2
BLU
J9
J1
Control Panel
Heater
2.7 kW @
230 VAC
Flow Sensor
Hi - limit / freeze sensor
Temperature sensor
Logic Jumper Settings
JP1 1-2 ON = 20A Logic
JP1 1-2 OFF = 30A Logic
JP1 3-4 ON = 2 Pump Operation
JP1 3-4 OFF = 1 Pump Operation
JP1 5-6 ON = 40A Logic (Remove JP1 1-2 Jumper)
JP1 5-6 OFF = Leave Off for 20A or 30A Logic
JP1 7-8 ON = Celsius Temperature Display
JP1 7-8 OFF = Fahrenheit Temperature Display
230 VAC 3-Wire Connection (50 Hz, 1-Phase Service), 1 Pump=15A/21A, 2 Pump=15A/29A,
USE COPPER CONDUCTORS ONLY. WIRE SIZE MUST MEET NEC RECOMMENDATONS
AND/OR LOCAL CODES AND IS DETERMINED BY MAXIMUM CURRENT DRAW AND
LENGTH OF RUN.
F1
20A, 250V
SC-20
BRN
J5
Transformer
230 VAC
BLU BRN
TB1
BLU
J6
J19
J18
J17
J16
J15
J14
J13
J12
BLU BRN
BRN
BLU
BLK
BRN
BLU
BRN
BLU
WHT
BLK
GRN
(not offered on all models)
(not offered on
all models)
CLEARRAY
Mini-Din Cable provides
constant 12 VAC from
yellow transformer wires
Mini-Din Control
Panel Cable
Ports 1-10
power spa
lights, waterfall
lights and step
lights on
applicable
models
J-200
16.3
Export 50 Hz J-235, J-245, J-275 and J-280 Models
This wiring diagram is used for the 230V 50 Hz Export spa models.
!
DANGER
Turn power off
before servicing. This
task should only be
performed by a qualified technician.
RISK OF SHOCK OR
ELECTROCUTION!
8
9
3
4
EXP BAR
1
J6
2
Main
Pump
J5
J17
HI
BLK
K5
J7
BLU
K7
BRN
J8
Heater IN
J4
K8
J1
J3
J2
J9
BRN
THERM
SWITCH
J10
Heater OUT
BLU
7
5
3
1
JP1
8
6
4
2
Temperature Sensor
Heater Specifications
Export Model:
2.7kW @ 230 VAC
(Thermo Switch - located inside
the heater for certain models)
Pressure Switch
Hi-limit/Freeze Sensor
Control Panel
J1 Logic Jumper Settings
JP1 1-2 ON = 20A Logic (Factory Setting)
JP1 1-2 OFF = 30A Logic
JP1 7-8 ON = °C Temperature Display
(Factory Setting)
JP1 7-8 OFF = °F Temperature Display
230 VAC 3-Wire Connection (50 Hz, 1-Phase Service),
USE COPPER CONDUCTORS ONLY. WIRE SIZE MUST MEET NEC RECOMMENDATIONS AND/
OR LOCAL CODES AND IS DETERMINED BY MAXIMUM CURRENT DRAW AND LENGTH OF RUN.
TB1
LO
F1
K4
K3
K2
K1
J20
Transformer
230 VAC
J15
J13
BLU
J11
J16
J14
J12
J21
F1 BRN
20A
250V
SC-20
BRN
BLU
BLU
Circ.
Pump
BRN
GRN BLU BRN
(not offered
on all models)
BRN
Mini-Din Cable provides
constant 12 VAC from
yellow transformer wires
Mini-Din Control
Panel Cable
Ports 1-10 power
spa lights, waterfall
lights and step lights
on applicable models
CLEARRAY
LED Lighting
System DCU
OR
EXP BAR
POWER
10
7
2
5
6
1
Light DCU
J-200
16.4
Export 50 Hz J-210 Models
This wiring diagram is used for all J-210 230V 50 Hz Export spa models.
51
J-200
17.0 Optional BLUEWAVE™ Spa Stereo System
To start enjoying your new stereo receiver, please read the following
operation instructions in their entirety.
3.5 mm cable
2
1
AUX
USB
3
4
6
30-pin
Connector
7
5
USB connector
1. Media Locker Handle
Slide the handle to lock and unlock the protective door.
2. Power Button
Press power button once to turn “ON” stereo system. Press a second
time to place the stereo in “Standby” mode and the red light will
remain illuminated.
3. Auxiliary Input Jack Connector
Allows you to connect an auxiliary device by using a 3.5 mm cable.
4. Universal Serial Bus (USB) Device Connector
Allows you to connect your device via a USB port and a USB cable
compatible with your device. Apple 30-pin cable supplied with
BLUEWAVE stereo.
5. Auxiliary Device Holding Base
The removable base securely holds the Auxiliary device, such as an
iPod®/MP3/iPhone, in place. It can be removed for larger devices.
6. 3.5 mm Cable
Use this cable to connect your Auxiliary or MP3 device to the stereo
via the “AUX” connection.
7. Apple 30-pin to USB Cable
Use this cable to connect your compatible iPod, iPhone or MP3
device to the stereo via the “USB” connection.
52
J-200
WARNING: RISK OF ELECTRICAL SHOCK HAZARD
EXISTS AND EQUIPMENT DAMAGE! Never install or
remove electrical devices (e.g. Apple device/MP3/USB/AUX/
Bluetooth) while hands are wet or while sitting partially or fully
immersed in the spa!
CAUTION: Never leave electrical devices in the Media Locker
when spa is not is use to prevent damage from outdoor
elements! Never spray Media Locker with a pressurized
water hose for any reason! Damage to the device or spa
stereo system caused by water intrusion is not covered
under the manufacturer’s warranty! Damage to Media Locker
port or electrical devices due to excessive force or improper
alignment during installation or removal from Media Locker is
not covered under warranty.
17.1
Pairing the Remote and Stereo
In order for the remote to operate the stereo, you
need to pair them using the following method:
1. Make sure the stereo unit is in “Standby” mode.
LED power light will be red, Figure A.
2. Press any button on the remote to turn it ON. The remote
LCD display will read “No Link.”
3. Press and hold the “Mode” button on the remote (Figure B).
At the same time, press and hold the power button on the
stereo for 2 seconds (Figure A).
4. The remote LCD display will read “Welcome,” “Load” and
“Radio” if the pairing sequence was successful.
Figure A
AUDIO
MODE
1
2
3
DIR -
REPEAT
DIR +
RANDOM
Figure B
17.2
Audio Settings
The Audio button, Figure C, provides access to many of the
stereo’s settings. By continually pressing the Audio button you
can scroll and adjust the following functions: BAS-TRE-BALFAD-DSP-AREA-LOUD-DX-STEREO (respectively).
Note: You can adjust the settings by pressing the Audio button,
making your adjustments and pressing the Audio button to go
Figure C
the next feature. If you exit the setting menus continually press
the Audio button until you reach the setting you would like to adjust.
AUDIO
MODE
1
2
3
DIR -
REPEAT
DIR +
RANDOM
1. Bass Setting: Press the Audio button once to access
the bass setting. The LCD display will change to “BAS
Figure D
0,” Figure D. Press the Up button to adjust the setting to a
maximum of +5. Press the Down button to adjust the setting down to
-5.
Note: The default setting is “0.” This feature is disabled when a “Digital
Sound Processor” (DSP) setting is active such as “Rock,” “Classic,” or
“Pop.”
53
J-200
2. Treble Setting: Press the Audio button 2 times to access
the treble setting. The LCD display will change to “TRE 0,”
Figure E
Figure E. Press the Up button to adjust the setting to a
maximum of +5. Press the Down button to adjust the
setting down to -5.
Note: The default setting is “0.” This feature is disabled when a “Digital
Sound Processor” (DSP) setting is active such as “Rock,” “Classic,” or
“Pop.”
3. Balance Setting: Press the Audio button 3 times to
access the balance setting. The LCD display will change
Figure F
to “BAL L=R,” Figure F. Press the Up button to adjust the
setting to a maximum of 10R (only the right side speakers will have
volume). Press the Down button to adjust the setting down to 10L
(only the left side speakers will have volume).
4. Fade Setting: Press the Audio button 4 times to access
the fade setting. The LCD display will change to “FAD
F=R,” Figure G. Press the Up button to adjust the setting to Figure G
a maximum of 10F (only the front speakers will have volume). Press
the Down button to adjust the setting down to 10R (only the rear
speakers will have volume).
5. Digital Sound Processor (DSP) Setting: Press the
Audio button 5 times to access the DSP setting. The LCD
display will change to “DSP OFF,” Figure H. Press the Up
button to select one of the preset settings such as Rock,
Classic or Pop. If a preset setting is select a small icon will
appear on the LCD display, Figure I.
Figure H
ROCK
Figure I
6. Area Setting: Press the Audio button 6 times to access
the Area setting. The LCD display will change to “AREA
USA,” Figure J. Press the Up button to select either USA or
EUR setting.
Figure J
7. Loud Setting: Press the Audio button 7 times to access
the Loud setting. The LCD display will change to “LOUD
OFF,” Figure K. Press the Up button to select either OFF
or ON.
Figure K
8. Distant Setting: Press the Audio button 8 times to
access the Distant setting. The LCD display will change to
Figure L
“DX,” Figure L. Press the Up button to select either Distant
(DX) or Local for station frequency. The “LOCAL” setting
allows for better FM reception when a local station is too
strong. Leave the setting to “DX” if this condition does not exist.
54
J-200
9. Stereo Setting: Press the Audio button 9 times to
access the Stereo setting. The LCD display will change to
“STEREO,” Figure M. Press the Up button to select either
Stereo or Mono.
17.3
Wireless Remote Control Functions
A wireless radio frequency (RF) remote control is supplied
on all spas with the optional audio system. This remote
provides control of the radio and over some media device’s
functions.
Figure M
AUDIO
MODE
1
2
3
DIR -
REPEAT
DIR +
A. External Media Device Playback
The supplied remote control provides no control over
external Auxiliary player operations except for volume control and source
selection. The Auxiliary player performs all external playback operations.
Button
AUDIO
MODE
RANDOM
Operation
Power Button: Press once to turn remote “ON” (remote LCD display
will read “No LInk”); Press second time to turn stereo “ON” (remote
LCD display will read “Welcome”); Press a third time to place the
stereo in “Standby” mode.
Audio Button: Allows access to most of the stereo sound functions.
Press continuously to scroll through the following settings: Bas-TreBal-Fad-DSP-Area-Loud-DX-Stereo.
Mode Button: Press continuously to switch between “RADIO,” “USB,”
and “AUX IN” modes. “BT AUDIO” appears when a Bluetooth device
in paired with the stereo.
Volume Up Button: Used to increase volume between 0 to 30.
Volume Down Button: Used to decrease volume between 30 to 0.
Button
1
DIR -
2
REPEAT
Device Mode (USB)
Radio Mode
Play/Pause Button: Press once
to pause track, press again to
resume playing
Mute Button: Press to mute
sound, press again to reactivate
sound
Track Down Button: Press to
rewind tracks.
Seek Down Button: Seeks down
for stations.
Track Up Button: Press to move
forward tracks.
Seek Forward Button: Seeks
forward for stations.
Press the button to change
music folders.
Preset 1: Press to access a preset station.
Apple Device: Press once to
repeat song. Press again to
repeat entire album. Press again
to turn off.
USB Mode: Press once to turn
on. Press again to turn off.
Preset 2: Press to access a preset station.
55
J-200
Button
3
DIR +
RANDOM
17.4
Device Mode (USB)
Radio Mode
Press the button to change
music folders.
Preset 3: Press to access a preset station.
Press to play songs in a random
order.
Not used
Electronic Device Connections and Functions
IMPORTANT:
• If stereo unit is “ON” (blue light is illuminated on the stereo power
button) then press the power button on the remote once.
•
If stereo unit is in “Standby” mode (red light is illuminated on the
stereo power button) then press the power button on the remote
once to activate the remote (remote LCD display will read “NO
LINK”). Press the button again to activate the stereo unit (remote
LCD display will read “WELCOME”).
A. Operating the Radio:
1. Turn power “ON” to the stereo unit. Press the power
Figure A
button on the remote.
2. The LCD screen on the remote will display the following: “Welcome,”
“Load,” “Radio” and the station number, Figure A.
3. You can use the seek button to search for frequencies.
4. You can save up to 3 stations as presets. Follow the steps below to
set a station:
a. Find a station you want to save.
b. Press and hold one of the three preset buttons. The station
preset number (1, 2, or 3) on the display will quickly flash to
confirm the setting. To set the additional two stations, conduct
this step again.
56
J-200
B. Connecting Your Apple Device and MP3 Player Using the USB:
1. Locate the USB port in the stereo locker (Figure B).
2. Locate the 30-pin cable provided for compatible devices (Figure C)
or a cable provided with your device.
3. Connect the USB end of the cable into the USB connection on
stereo.
4. Connect the 30-pin end of the cable to the Apple device/MP3 Player
(purchased separately), Figure D.
5. After connecting the cable to both devices, set the player into the
rubber holding base, Figure E.
Note: This also charges most compatible Apple devices when
connected.
AUX
USB
AUX
USB
ACCESSORY CONNECTED
Figure B
Figure C
Figure D
(device purchased
separately)
Figure E
CAUTION: RISK OF ELECTRICAL SHOCK OR
EQUIPMENT DAMAGE!
Never install, remove or operate any electrical device (e.g.
Apple device/MP3/USB/AUX/Bluetooth) while hands are wet
or while sitting partially or fully immersed in the spa!
Note: The DRM (Digital Rights Management) Files cannot be played
on this deck. Personal files (MP3, WMA, iTunes or AAC) can be
played as long as they are not DRM encrypted.
C. Operating MP3/USB/Apple Device:
1. Turn power “ON” to the stereo unit. Turn power “ON” to the remote.
2. The LCD screen on the remote will display the following: “Welcome,”
“USB,” “Load,” “Apple” (final display will vary depending on the
device connected). All functions are performed through the remote.
3. While the music is playing the remote screen will display and
continually scroll through the following: Artist, Album, Song and Track
information.
4. For operational functions refer to the “External Media Device
Playback” section.
57
J-200
D. Operating the USB drive:
1. Plug in your USB device into the “USB” connection on the stereo,
Figure A.
2. Turn power “ON” to the stereo unit and the stereo remote.
3. The LCD screen on the remote will display the following: “Welcome,”
“USB,” “Load,” “TOL XX” (final display will vary depending on the
whether the USB holds folders or files). All functions are performed
through the remote.
4. While the music is playing the remote screen will display and
continually scroll through the following: Title, Song, Artist, Album, Dir,
Music and Track information.
5. For operational functions refer to the “External Media Device
Playback” section.
E. Connecting Your Auxiliary Player Using the 3.5 mm Cable:
1. Plug one end of the cable to “Aux” connection on the
stereo, Figure F.
2. Plug the other end of the supplied cable into the
head phone jack connection on the Apple device/
MP3 Player.
3. Press the Mode button on the remote to “AUX IN.”
4. All playback operations are conducted via the
Figure F
Auxiliary Player. The stereo remote functions do not work on
the external Auxiliary Player (except volume control).
AUX
USB
Connecting Your Bluetooth Device:
Turn power “ON” to the stereo unit.
From your Bluetooth device, make sure the Bluetooth setting is “ON.”
Follow the pairing instructions for your Bluetooth device and connect
to the “BLUEWAVE” device that appears on your screen.
4. If asked for a password, enter the code “0000.”
5. The remote LCD screen will display, “BT AUDIO” if the process was
successful.
F.
1.
2.
3.
G. Operating Your Bluetooth Device:
1. Press the seek up or down buttons to scroll through the tracks (on
the remote).
2. Press the volume up or down buttons to adjust volume level between
0 to 30 (on the remote).
3. Any other playback operations are conducted via the Bluetooth
device.
CAUTION: RISK OF ELECTRICAL SHOCK OR
EQUIPMENT DAMAGE!
Never install, remove or operate any electrical device (e.g.
Apple device/MP3/USB/AUX/Bluetooth) while hands are wet
or while sitting partially or fully immersed in the spa!
58
J-200
17.5
Wireless Remote Battery Replacement Procedure
1. Turn the remote unit over and locate the battery door
(Figure A).
Battery
OPEN
CLOSED
30
24
CR 3V
Door
Fig. A
OPEN
Fig. B
OPEN
CLOSED
CR2430
3V
3. Remove battery door by lifting the door upward (Figure C).
CLOSED
CR2430
3V
2. Rotate the battery door, with a coin, counterclockwise to
the Open position (Figure B). When the door is unlocked it
will pop up slightly.
Fig. C
CLOSED
OPEN
4. Replace battery using CR2430 or equivalent (Figure D).
CR2430
3V
Fig. D
5. Reinstall the battery cover, using the coin rotate the door
to the Close position (Figure E).
OPEN
CLOSED
30
24
CR 3V
Note: Remote unit is water resistant not waterproof. Although it is Fig. E
designed for use while in the spa, it should never be left in the spa while
the cover is on and spa is not in use. The remote should be stored in a
dry location such as the stereo remote pouch (if applicable) located on
the outside of the spa cover or within your home. Extreme weather can
affect the remote control battery. In extreme hot or cold environments
store the remote control indoors to prolong battery life.
17.6
Bluewave Spa Stereo System Specifications
Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.7-14.4V DC
Tuner
FM radio sensitivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8uV
FM radio reception . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Stereo
59
J-200
17.7
Stereo Cautions
1.
“CAUTION - Risk of Electric Shock. Do not
leave compartment door open.”
2.
“CAUTION - Risk of Electric Shock. Replace
components only with identical components.”
!
DANGER
RISK OF SHOCK OR
ELECTROCUTION!
3. “Do not operate the audio/video controls while inside
in the spa.”
4.
“WARNING - Risk of Electrocution. Do not connect any auxiliary
components (for example cables, additional speakers, headphones,
additional audio/video components, etc.) to the system.”
5. These units are not provided with an outdoor antennae; when
provided, it should be installed in accordance with Article 810 of the
National Electrical Code, ANSI/NFPA 70.
6. Do not service this product yourself as opening or removing covers
may expose you to dangerous voltage or other risk of injury. Refer all
servicing to qualified service personnel.
7. When the power supply connections or power supply cord(s) are
damaged; if water is entering the audio/video compartment or any
electrical equipment compartment area; if the protective shields or
barriers are showing signs of deterioration; or if there are signs of
other potential damage to the unit, turn off the unit and refer servicing
to a qualified service personnel.
8. This unit should be subjected to periodic routine maintenance
(for example, once every 3 months) to make sure that the unit is
operating properly.
60

advertisement

Key Features

  • Advanced water filtration system
  • Automatic filtration cycle
  • Multi-colored LED light system
  • BLUEWAVE™ Spa Stereo System
  • CLEARRAY® Water Purification System
  • Adjustable jet flow

Related manuals

Frequently Answers and Questions

What are the recommended water chemistry parameters for my spa?
The recommended water chemistry parameters are listed on the inside cover of this manual. Always maintain your spa’s water chemistry within these parameters.
How often should I clean the filter cartridge?
You should clean the filter cartridge once a month, or earlier as necessary. Refer to page 32 for detailed instructions.
How often should I replace the spa water?
You should replace the spa’s water every 3 months. The frequency depends on a number of variables including frequency of use, number of users, and attention paid to water quality maintenance.
What are the error conditions/error messages that may appear on the control panel?
Refer to Section 14.0 for a list of error conditions/error messages and what they mean.
What should I do if my spa is not heating up?
Refer to Section 15.0 for troubleshooting procedures. You may need to check the electrical connections, the thermostat setting, or the heater itself.
What is the CLEARRAY® Water Purification System?
The CLEARRAY® Water Purification System is a factory installed system that utilizes ultraviolet light to sanitize your spa water. It requires an annual bulb replacement.
Download PDF

advertisement