Rheem ECO180DVELN3-1 Performance Plus 8.4 GPM Natural Gas Indoor Smart Tankless Water Heater Use and Care Manual 84 Pages
Rheem ECO180DVELN3-1 is a high-performance tankless water heater designed to provide an endless supply of hot water for your home. With its advanced technology and innovative features, this water heater offers exceptional heating capabilities while ensuring energy efficiency and safety. It is ideal for both residential and commercial applications, including homes, apartments, offices, and businesses.
Rheem ECO180DVELN3-1 Performance Plus 8.4 GPM Natural Gas Indoor Smart Tankless Water Heater Use and Care Manual
Rheem ECO180DVELN3-1 is a high-performance tankless water heater designed to provide an endless supply of hot water for your home. With its advanced technology and innovative features, this water heater offers exceptional heating capabilities while ensuring energy efficiency and safety. It is ideal for both residential and commercial applications, including homes, apartments, offices, and businesses.
advertisement
Ask Al about Rheem ECO180DVELN3-1 Performance Plus 8.4 GPM Natural Gas Indoor Smart Tankless Water Heater Use and Care Manual
Chatbot has read manual and is ready to answer your questions.
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
WARNING:
If the information in these instructions is not followed exactly, a fire or explosion may result, causing death, personal injury, or property damage.
For Your Safety!
• Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. To do so may result in an explosion or fire.
• Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
What to Do If
You Smell Gas
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
• Do not return to your home until authorized by the gas supplier or fire department.
TANKLESS
WATER HEATER
USE AND CARE MANUAL
With Installation Instructions for the Installer
Noncondensing 199,900 Btu/hr, 180,000 Btu/ hr, and 150,000 Btu/hr Models
CERTIFIED
R
Do not destroy manual. Please read carefully and keep in a safe place for future reference.
WARNING:
• This water heater is not suitable for use in manufactured (mobile) homes.
AP18000 (02/16)
2
CONTENTS
Important Safety Information
Safety Precautions ������������������������������������������������������������� 2–8
Product Information
Product Information ��������������������������������������������������������������� 8
Specifications ������������������������������������������������������������������ 9, 10
General Descriptions �������������������������������������������������������11, 12
Using Your Water Heater
Setting the Water Temperature ��������������������������������������� 13, 14
Caring for Your Water Heater
Water Heater Inspections ���������������������������������������������� 15, 16
Care and Cleaning �����������������������������������������������������������17, 18
Preventive Maintenance ������������������������������������������������������� 19
Draining the Water Heater ����������������������������������������������� 20–22
Freeze Protection ����������������������������������������������������������������� 22
Vacation and Extended Shutdown �������������������������������������� 23
Troubleshooting Chart��������������������������������������������������� 23, 24
Service Error Code Chart ���������������������������������������������� 25, 26
If You Need Service
Call for Assistance ��������������������������������������������������������������� 26
Installation Instructions
Standards Compliance ����������������������������������������������������������28
Choosing a Location ������������������������������������������������������� 28, 29
Product Inspection ��������������������������������������������������������������� 30
Water Heater Installation �������������������������������������������������30–33
Venting ����������������������������������������������������������������������������34–45
Water Quality/Supply ������������������������������������������������������46–50
Gas Supply ����������������������������������������������������������������������50–55
Electrical Wiring ��������������������������������������������������������������55–59
Remote Control Installation �������������������������������������������� 58, 59
Insulation Blankets and Installation Precautions ������������������60
Installation Checklist �������������������������������������������������������������61
Piping for Space Heaters ������������������������������������������������������62
Recirculation Control ������������������������������������������������������ 63-65
Activating the Water Heater ��������������������������������������������������66
Operating Instructions ����������������������������������������������������������67
Setting the Water Temperature ��������������������������������������� 68–70
High-Altitude Dip Switch Adjustments����������������������������70, 71
Water Saving Control Option ������������������������������������������72, 73
Maintenance Notice Option ���������������������������������������������74, 75
Parts Ordering ����������������������������������������������������������������76, 77
Warranty Information������������������������������������������������������79, 80
IMPORTANT SAFETY INFORMATION
READ THE SAFETY INFORMATION
Your safety and the safety of others are very important.
There are many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
!
WARNINGS:
• This water heater is not suitable for use in manufactured
(mobile) homes!
!
This is the safety alert symbol. Recognize this symbol as an indication of Important Safety
Information! This symbol alerts you to potential hazards that can kill or hurt you and others.
• Improper installation, adjustment, alteration, service, or maintenance can cause death, personal injury, or property damage. Follow the instructions in this manual.
All safety messages will follow the safety alert symbol and either the word “DANGER,” “WARNING,” “CAUTION,” or “NOTICE.”
READ ALL INSTRUCTIONS
BEFORE USING.
These words mean:
!
DANGER:
An imminently hazardous situation that will result in death or serious injury.
!
WARNING:
A potentially hazardous situation that can result in death or serious injury and/or damage to property.
!
CAUTION:
A potentially hazardous situation that may result in minor or moderate injury.
NOTICE:
Attention is called to observe a specified procedure or maintain a specific condition.
Be sure to read and understand the entire Use and Care Manual before attempting to install or operate this water heater� It may save you time and money� Pay particular attention to the Safety
Instructions� Failure to follow these warnings could result in death or serious bodily injury� Should you have problems understanding the instructions in this manual, or have any questions, STOP and get help from a qualified service technician or the local gas utility�
!
WARNING:
California Proposition 65
This product contains chemicals known to the state of California to cause cancer, birth defects, or other reproductive harm.
IMPORTANT SAFETY INFORMATION
Water Heater Venting Safety
!
DANGER:
• Failure to install and properly vent the water heater to the outdoors as outlined in the
“Venting” section of the Installation Instructions in this manual will result in death from fire, explosion, or asphyxiation from carbon monoxide. NEVER operate this water heater unless it is properly vented and has an adequate air supply for proper operation.
• Be sure to inspect the vent terminal, the air intake, and the coaxial vent system on the water heater for proper installation at initial start-up and at least annually thereafter.
Refer to the “Care and Cleaning” section of this manual for more information regarding coaxial vent system inspection.
!
WARNINGS:
• Gasoline and other flammable liquids, materials, and vapors (including paint thinners, solvents, and adhesives) are extremely dangerous.
DO NOT handle, use, or store gasoline or other flammable or combustible materials anywhere in the vicinity of a water heater or any other appliance. Be sure to read and follow the labels on the water heater, as well as the warnings printed in this manual. Failure to do so can result in death, bodily injury, or property damage.
• Combustible construction refers to adjacent walls and ceilings and should not be confused with combustible or flammable products and materials. Combustible materials, such as clothing, cleaning materials, or flammable liquids, should never be stored in the vicinity of this or any gas appliance. Fire or explosion can occur causing death, personal injury, and/or product damage. See page 29 for clearances to combustible materials.
• Follow vent manufacturer’s instructions for venting installation, including additional clearances from combustibles, to avoid conditions that can lead to death, personal injury, and/or property damage.
• Use tankless water heater manufacturerapproved Category III Stainless Steel vent material only. No other vent material is permitted.
• Moisture in the flue gas will condense as it leaves the vent terminal. In cold weather this condensate can freeze on the exterior wall, under the eaves, and on surrounding objects.
Some discoloration to the exterior of the building is to be expected. However, improper location or installation can result in severe damage to the structure or exterior finish of the building.
D A N G E R
FLAMMABLES Flammable Vapors
Vapors from flammable liquids will explode and catch fire causing death or severe burns.
Do not use or store flammable products such as gasoline, solvents or adhesives in the same room or area near the water heater.
Keep flammable products:
1. far away from heater,
2. in approved containers,
3. tightly closed and
4. out of children's reach.
Water heater has a main burner flame.
The main burner flame:
1. which can come on
at any time and
2. will ignite flammable
vapors.
Vapors:
1. cannot be seen,
2. are heavier than air,
3. go a long way on the
floor and
4. can be carried from
other rooms to the
main burner flame by
air currents.
Installation:
Do not install water heater where flammable products will be stored or used unless the main burner flame is at least
18" above the floor. This will reduce, but not eliminate, the risk of vapors being ignited by the main burner flame.
Read and follow water heater warnings and instructions. If owners manual is missing, contact the retailer or manufacturer.
• For multiple-unit installation, a minimum distance between vent terminations must be maintained to prevent recirculation of vent gases.
Maintain a center-to-center distance between vent terminations of 19 in. (48 cm) for two-unit installation. Maintain a center-to-center distance between vent terminations of 21 in. (53 cm) for installation of three or more units.
!
CAUTIONS:
• Ensure that the appliance vent is securely attached to the water heater collar.
• Condensate must drain away from the water heater and should not be allowed to drain back into any part of the vent system.
• DO NOT operate without the condensate trap connected to the vent and routed to the proper drain.
• Follow the vent manufacturer’s installation instructions because the design might vary from manufacturer to manufacturer.
3
4
IMPORTANT SAFETY INFORMATION
Water Supply Safety
!
DANGERS:
• WATER TEMPERATURE
SETTINGS – Safety and energy conservation are factors to be considered when selecting the water temperature setting of a water heater’s remote control.
Water temperatures above
125°F (52°C) can cause death or severe burns from scalding.
Be sure to read and follow the warnings outlined on the pictured label.
!
D A N G E R
!
CAUTIONS:
• This water heater must only be used with the following water supply system conditions:
• There is a hot water scald potential if the water temperature is set too high.
Households with small children, the disabled, or elderly persons may require a 120°F (49°C) or lower temperature setting to prevent contact with “HOT” water.
• Before manually operating the relief valve, make certain no one will be exposed to the danger of the hot water released by the valve. The water may be hot enough to create a scald hazard. The water should be released into a suitable drain to prevent injury or property damage.
Water temperature over 125 °
can cause severe burns
F
instantly or death from scalds.
Children, disabled and elderly are at highest risk of being scalded.
See instruction manual before setting temperature at water heater.
Feel water before bathing or showering.
Temperature limiting valves are available, see manual.
• Failure to perform the recommended Routine Preventive Maintenance can harm the proper operation of this water heater, which can cause carbon monoxide dangers, excessive hot water temperatures, and other potentially hazardous conditions.
HOT
BURN
Time/Temperature Relationship in Scalds
Water
• Even when drained properly, a small amount of water will remain in the water heater.
In cold weather conditions, this water can freeze. If this happens, allow the defrost protection on the heater at least
30 minutes to melt the frozen water or the water heater may not work properly.
Temperature
120°F (49°C)
– With inlet water temperatures above 32°F
(0°C), but not exceeding
120°F (49°C).
– DO NOT reverse the hot and cold water connections. The water heater will not operate.
Time to Produce
a Serious Burn
More than 5 minutes
!
WARNINGS:
• IMPORTANT: DO NOT apply heat to the HOT or
COLD water connections. If sweat connections are used, sweat tubing to adapter before fitting adapter to the water connections on heater.
Any heat applied to the water supply fittings will permanently damage the internal components of the water heater.
• In case the pipe insulation is not rated for the appropriate weather conditions, install electric heat tracing or equivalent to prevent freezing of the pipes. DO NOT insulate or block the drain valve on the hot outlet fitting. If the pipes are allowed to freeze, the water heater and the pipes may malfunction or leak due to freezing water.
125°F (52°C)
130°F (54°C)
135°F (57°C)
140°F (60°C)
145°F (63°C)
150°F (66°C)
155°F (68°C)
Table courtesy of Shriners Burn Institute
85
29
100
38 39
About 10 seconds
Less than 5 seconds
Temperature Conversion Chart °F/°C
102 104
40
– With clean, potable water free of corrosive chemicals, sand, dirt, or other contaminants.
41 42
1 1/2 to 2 minutes
106 108
About 30 seconds
Less than 3 seconds
About 1 1/2 seconds
About 1 second
110 112
43 44
°F
°C
• Failure to drain the water heater as described on page 20 can cause serious personal injuries from scalding and/or damage the water heater.
114 116 118 120 125 130 140 °F
46 47 48 49 52 54 60 °C
IMPORTANT SAFETY INFORMATION
Natural Gas and Liquefied Petroleum Safety
!
DANGERS:
• Never attempt to convert the water heater from natural gas to LP. The water heater should only use the fuel type in accordance with listing on data plate—natural gas for natural gas units and
LP for LP units. Any other fuel usage will result in death or serious personal injury from fire and/ or explosion. This water heater is not certified for any other fuel type.
• Both natural gas and propane (LP) have an odorant added to aid in detecting a gas leak.
Some people may not physically be able to smell or recognize this odorant. If you are unsure or unfamiliar with the smell of natural gas or LP, ask the gas supplier. Other conditions, such as “odorant fade,” which causes the odorant to diminish in intensity, can also hide or camouflage a gas leak.
• Water heaters using LP gas are different from natural gas models. A natural gas water heater will not function safely on LP and vice versa.
• LP water heaters should not be installed below grade (for example, in a basement) if such installation is prohibited by federal, state, and/or local laws, rules, regulations, or customs.
• LP must be used with great caution. It is heavier than air and will collect first in lower areas, making it hard to detect at nose level.
• Before attempting to light the water heater, make sure to look and smell for gas leaks. Use a soapy solution to check all gas fittings and connections. Bubbling at a connection indicates a leak that must be corrected. When smelling to detect a gas leak, be sure to also sniff near the floor.
• Gas detectors are recommended in LP and natural gas applications and their installation should be in accordance with the detector manufacturer’s recommendations and/or local laws, rules, regulations, or customs.
• Combustible materials, such as clothing, cleaning materials, or flammable liquids, must not be placed in the vicinity of the water heater.
• If a gas leak is present or suspected:
– DO NOT attempt to find the cause yourself.
!
WARNINGS:
•
The installation of gas piping must conform to local utility company requirements and/or in the absence of local codes, use the latest edition of
National Fuel Gas Code (NFGC), ANSI Z223.1/
NFPA 54, or CAN/CSA B149.1, Natural Gas and
Propane Installation Code.
• If inlet gas pressure is out of allowable range
[4.0” w.c. (1.0kPa) – 10.5” w.c. (2.6kPa)] for
Natural Gas, or [8.0” w.c. (2.0kPa) – 13.0” w.c.
(3.2kPa)] for LP gas, a gas pressure regulator must be installed to maintain the allowable inlet gas pressure.
• Should overheating occur or the gas supply fail to shut off, turn off the manual gas control valve to the water heater.
!
CAUTIONS:
• DO NOT attempt repair of electrical wiring, gas piping, remote control, burners, vent connectors, or other safety devices. Refer repairs to qualified service personnel.
• Turn off the manual gas shut-off valve if the water heater has been subjected to overheating, fire, flood, physical damage, or if the gas supply fails to shut off.
• DO NOT turn on the water heater unless the water and gas supplies are completely opened.
NOTICE:
• The factory setting allows operating temperatures between 100°F (38°C) and 120°F
(49°C). Temperatures of 85°F (29°C) and up to
140°F (60°C) can be achieved with the MAIN
(UMC-117) remote control. Temperatures of 85°F
(29°C) can be achieved with the Bath (USC-117 or
USC2-117) remote control. Only qualified service personnel should perform this adjustment. Only factory-authorized remote control(s) should be used.
– Never use an open flame to test for gas leaks. The gas can ignite resulting in death, personal injury, or property damage.
– Follow the steps listed under “What to Do If
You Smell Gas” found on the front cover of this manual.
5
IMPORTANT SAFETY INFORMATION
Before operating this water heater, be sure to read and follow the instructions on the label pictured below and all other labels on the water heater, as well as the warnings printed in this manual. Failure to do so can result in unsafe operation of the water heater, resulting in death, personal injury, or property damage.
Should you have any problems reading or following the instructions in this manual, STOP and get help from a qualified service technician.
FOR YOUR SAFETY READ BEFORE OPERATING
WARNING
: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
6
OPERATING INSTRUCTIONS
1.STOP! Read the safety information above on this label.
2.Turn off all electric power to the appliance.
GAS SHUTOFF
3.Do not attempt to light the burner by hand.
VALVE
4.Turn the Gas Shutoff Valve located on the outside of the unit
OPEN CLOSE
clockwise to the "OFF" position.
5.Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow "B" in
the safety information above on this label. If you don't smell gas, go to the next step.
6.Turn the Gas Shutoff Valve located on the outside of the unit counterclockwise to
the "ON" position.
7.Turn on all electric power to the appliance.
8.If the appliance will not operate, follow the instructions "To Turn Off Gas To Appliance"
and call your service technician or gas supplier.
TO TURN OFF GAS TO APPLIANCE
1.Turn off all electric power to the appliance if service is to be performed.
2.Turn the Gas Shutoff Valve located on the outside of the unit clockwise to the "OFF" position.
IMPORTANT SAFETY INFORMATION
Electrical Safety
!
DANGER:
• Shock Hazard – Make sure the electrical power to the water heater is off to avoid electric shock that will result in death or serious personal injury.
!
WARNINGS:
• For your safety, the information in this manual must be followed to minimize the risk of fire, explosion, or electric shock that can result in death, personal injury, and/or property damage.
• Field wiring connections and electrical grounding must comply with local codes or, in the absence of local codes, with the latest edition of the National Electrical Code, ANSI/
NFPA 70, or in Canada, Canadian Electrical
Code, CAN/CSA C22.1, Part 1.
!
CAUTIONS:
• Label all wires prior to disconnecting for service.
Wiring errors can cause dangerous and improper operation. Verify correct operation after servicing.
• For your safety, burner inspection and cleaning should be performed only by qualified service personnel.
• Make certain the power to the water heater is OFF before removing the unit cover panel.
Exposed electrical components and moving parts can cause personal injuries.
• For your safety, DO NOT attempt repair of electrical wiring, gas piping, remote control, burners, vent connectors, or other safety devices. Refer repairs to qualified service personnel.
FOR INSTALLATIONS IN THE STATE OF CALIFORNIA
California law requires that water heaters must be braced, anchored, or strapped to resist falling or horizontal displacement due to earthquake motions.
For water heaters up to 52-gallon capacity, a brochure with generic earthquake bracing instructions can be obtained from: Office of the State Architect, 1102 Q
Street, Suite 5100, Sacramento, CA 95814, or you may call 916-445-8100 or ask a water heater dealer.
However, applicable local codes shall govern installation. For residential water heaters of a capacity greater than 52 gallons or tankless-style, consult the local building jurisdiction code for acceptable bracing procedures.
7
8
IMPORTANT SAFETY INFORMATION
General Installation and Maintenance Safety
!
WARNINGS:
• This water heater must be installed in accordance with these instructions, local codes, utility company requirements and/or in the absence of local codes, use the latest edition of the American National Standard/
National Fuel Gas Code (NFGC), ANSI Z223.1 and National Fire Protection Association,
NFPA 54, or in Canada, CAN/CSA B149.1,
Natural Gas and Propane Installation Code, and the latest edition of the National Electrical
Code, ANSI/NFPA 70, or in Canada, Canadian
Electrical Code, CAN/CSA C22.1, Part 1.
• If local codes require the application of external insulation blanket kits, carefully follow the manufacturer’s installation instructions included with the kit. Only use blanket kits that are approved for use with your water heater.
• For your safety, DO NOT attempt to disassemble this water heater for any reason. Improper adjustments, alterations, service, or maintenance can cause death, personal injury, or property damage.
SAFETY PRECAUTIONS:
• Read this manual entirely before installing and/ or operating the water heater.
• Use this water heater only for its intended purpose as described in this Use and Care
Manual.
• Have the installer show you the location of the gas shut-off valve and how to shut it off if necessary. Turn off the manual shut-off valve if the water heater has been subjected to overheating, fire, flood, physical damage, or if the gas supply fails to shut off.
• Be sure your water heater is properly installed in accordance with local codes and the provided installation instructions.
• DO NOT attempt to repair or replace any part of your water heater unless it is specifically recommended in this manual. All other servicing should be referred to a qualified service technician.
SAVE THESE
INSTRUCTIONS
PRODUCT INFORMATION
Read This Manual
For Your Records
Inside you will find many helpful hints on how to use and maintain your water heater properly. A little preventive care on your part can save you time and money over the life of your water heater.
Write down and save the following product information along with the original sales slip and/ or cancelled check.The model and serial numbers can be found on the top label on the right side of the water heater.
You’ll find many answers to common problems in the
Troubleshooting Chart on pages 23 and 24� Always refer to this chart before calling for service� Referring to this chart before calling may answer your question(s) and eliminate the need for service�
Preoperating Checklist
MODEL NUMBER:
SERIAL NUMBER:
DATE OF INSTALLATION:
INSTALLING COMPANY/PHONE NUMBER:
PLUMBING CONTRACTOR/PHONE NUMBER:
Is the main gas valve to the water heater turned on?
Is the fuse in place or is the breaker turned on?
Does the water heater’s electronic ignition light?
Is the water temperature set to a safe temperature?
Is the water heater connected to a floor drain?
Is the water heater properly vented to the outside?
Is the water heater installed in a safe location away from flammable materials and/or freezing conditions?
See page 26 for additional service information.
Specifications – Direct-Vent Models
PRODUCT INFORMATION
5 3 /
16
"
(131 mm)
5 3 /
16
"
(131 mm)
13 1 /
2
"
(343 mm)
13 1
6 3 /
4
"
(172 mm)
/
2
"
(343 mm)
6 3 /
4
"
(172 mm)
29 13 /
16
"
(757 mm)
29 13 /
16
"
(757 mm)
25 5 /
8
"
(651 mm)
25 5 /
8
"
(651 mm)
1 9 /
16
"
(40 mm)
1 9 /
16
"
(40 mm)
13 15 /
16
"
(354 mm)
13 15 /
16
"
(354 mm)
1 3 /
4
"
(45 mm)
1 3 /
4
"
(45 mm)
9 1 /
2
"
(241 mm)
9 1 /
2
"
(241 mm)
5 1 /
2
"
(140 mm)
5 1 /
2
"
(140 mm)
4 3 /
16
"
3
(106 mm)
3 /
8
"
(86 mm)
4 3 /
16
3 3 /
8
"
(86 mm)
"
5
(106 mm)
5 /
8
"
(143 mm)
5 5 /
8
"
(143 mm)
5 5 /
8
"
(143 mm)
5 5
3 5 /
/
8
"
8
"
(143 mm)
3 5 /
8
"
(92 mm)
Specifications – Outdoor Models
13 1 /
2
"
(343 mm)
13 1 /
2
"
(343 mm)
26 13 /
16
26 13 /
16
" 23 3 /
4
"
(603 mm)
23 3 /
4
"
(603 mm)
1 9 /
16
" 1 9 /
16
"
(40 mm)
13 15 /
16
"
(354 mm)
13 15 /
16
"
(354 mm)
1 3 /
4
"
(45 mm)
1 3 /
4
"
(45 mm)
8 1 /
2
" 8 1 /
2
"
(216 mm)
4 3 /
16
" 4 3 /
16
"
(106 mm)
2 1 /
16
"
2 7 /
8
"
(73 mm)
2 7 /
8
5
2
5
1
/
/
8
16
"
"
(53 mm) 5 5 /
8
"
(143 mm)
5 5 /
8
"
2 1 /
4
"
5 5 /
8
"
(143 mm)
2 1 /
4
"
(58 mm)
9
PRODUCT INFORMATION
Specifications
The following product information can be found from the rating label on this water heater�
A� Model Number
B� Serial Number
C� Data Bar Code
D� Heater Type
E� Installation Type
F� Type of Gas
G� Max� Inlet Gas Pressure
H� Min� Inlet Gas Pressure
J� Recovery Rating
K� Max� BTU Input Rating
L� Min� BTU Input Rating
M� Manifold Gas Pressure
N� Certification Stamp
P� Alternate Approval Stamp
Q� Clearances
English Rating Label
English/French Rating Label
10
PRODUCT INFORMATION
General Descriptions
Typical Direct-Vent Water Heater
(Venting Required)
Condensate
Collector
Remote Control
With Power Switch
To Drain: Dispose of condensate in accordance with local codes.
To Hot Water
Faucet(s)
Drain Valve
Water
Filter
Power
Supply
Cord
Union
Relief
Valve
Manual Gas
Shut-Off Valve
Union
Manual Gas
Supply Line
Shut-Off Valve
Service
Valve
Cold Water Supply
Shut-Off Valve
6"
(150 mm)
Air Gap
Discharge Line
(To Suitable Drain)
Sediment Trap (in accordance with the local gas authority)
Cap
11
PRODUCT INFORMATION
Typical Outdoor Water Heater
(No Venting Required)
This water heater is for OUTDOOR installation only.
!
DANGER:
DO NOT install this water heater indoors or in a confined area. It is designed for outdoor installation only. Any other type of installation will result in death or serious personal injury.
Flue
Terminal
Remote Control
With Power Switch
(Installed Indoor)
Air Inlet
Hard-Wire
Water
Filter
To Hot Water
Faucet(s)
Power Supply
Cord
(not supplied)
Union
Relief
Valve
Relief
Valve
Service
Valve
Drain Valve
Manual Gas
Shut-Off Valve
Union
Manual Gas
Supply Line
Shut-Off Valve
Cold Water Supply
Shut-Off Valve
6"
(150 mm)
Air Gap
Discharge Line
(To Suitable Drain)
Sediment Trap (in accordance with the local gas authority)
Cap
12
Safety Precautions
!
WARNING:
• Flammable vapors can be drawn by air currents from surrounding areas to the water heater. Vapors can ignite causing death, personal injury, or product damage.
• DO NOT store or use flammable or combustible materials (gasoline, paint thinner, adhesives, newspapers, rags, mops, etc.) in the vicinity of the water heater or any other gas appliance. If they must be used, open doors and windows for ventilation, and shut off all gas-burning appliances, including their pilot lights.
USING YOUR WATER HEATER
• DO turn off manual gas shut-off valve if water heater has been subjected to overheating, fire, flood, physical damage, or if the gas supply fails to shut off.
• DO NOT turn on water heater unless water and gas supplies are completely opened.
• If there is any difficulty in understanding or following the operating and care instructions in this manual, it is recommended that you contact a qualified service technician to perform the work.
Setting the Water Temperature
!
DANGER:
Water temperatures above 125°F (52°C) will result in death and/or severe burns from scalding.
Safety and energy conservation are factors to be considered when selecting the water temperature setting. The temperature of the water in the water heater can be regulated by setting the temperature on the front of the remote control.
Be sure to read and follow the warnings outlined on the pictured label.
The remote control has been preset and shipped at the recommended temperature setting.
Safety factors should be considered whenever altering the water temperature setting. The chart below may be used as a guide in determining the proper water temperature for your home.
Time/Temperature Relationship in Scalds
Water
Temperature
Time to Produce
a Serious Burn
120°F (49°C)
125°F (52°C)
130°F (54°C)
135°F (57°C)
140°F (60°C)
145°F (63°C)
150°F (66°C)
155°F (68°C)
Table courtesy of Shriners Burn Institute
More than 5 minutes
1 1/2 to 2 minutes
About 30 seconds
About 10 seconds
Less than 5 seconds
Less than 3 seconds
About 1 1/2 seconds
About 1 second
!
D A N G E R
HOT
BURN
Water temperature over 125 °
can cause severe burns
F
instantly or death from scalds.
Children, disabled and elderly are at highest risk of being scalded.
See instruction manual before setting temperature at water heater.
Feel water before bathing or showering.
Temperature limiting valves are available, see manual.
13
USING YOUR WATER HEATER
Setting the Water Temperature (cont.)
Maximum water temperature occurs while the water heater burner is on. To determine the water temperature:
NOTICE:
The temperature set point on the standard remote control cannot be increased above
112°F (44°C) when a hot water faucet is in the open position. To achieve temperatures above
120°F (49°C) or below 85°F (29°C), contact a qualified service technician. Only factoryauthorized remote control(s) should be used.
The water heater may not operate with a small water flow� Increase the water flow and recheck� If it still does not operate with the hot water faucet completely open, increase the temperature setting on the remote control�
Turn on the hot water faucet and place a thermometer in the water stream.
NOTICE:
Water temperature at the faucet may vary depending on the season and the length of pipe from the water heater.
The remote control temperature range is between 100°F
(38°C) and 120°F (49°C)� To adjust the temperature to a desired setting, press the UP or DOWN adjustment button on the face of the remote control� The new temperature set point will show on the LED display�
In-Use Indicator
(Lit during operation)
Priority
Indicator
Water Heater Facts
!
DANGER:
Water temperatures above 125°F (52°C) will result in death and/or severe burns from scalding.
• The hottest-temperature water will be at the faucet closest to the water heater�
• Always remember to test the water temperature with your hand before use�
• Always supervise young children or others who are incapacitated�
• The water heater is equipped with a device that will shut off the gas supply to the burner if the water heater exceeds normal operating temperatures�
• Any water heater that has been subjected to fire, flood, physical damage, or been under water should be turned off at the manual gas shut-off valve and not used until it has been checked by qualified service personnel�
Temperature
Adjustment
Buttons
14
LED Temperature and
Error Code Display
Power ON/OFF
Button and
Indicator
CARING FOR YOUR WATER HEATER
Water Heater Inspections
Venting System (Direct Vent Only)
The venting system should be inspected annually by a qualified service technician to ensure all of the vent sections are secure and airtight�
!
WARNING:
DO NOT operate the water heater if the vent system shows signs of leaking exhaust.
Leaking exhaust could lead to death, personal injury, and/or product failure.
Outdoor models
Condensate Trap (Direct Vent Only)
!
CAUTION:
DO NOT operate without the condensate trap connected to the vent and routed to the proper drain. It could cause the system to malfunction or fail.
On a regular basis, inspect the condensate trap to ensure there is enough water in the trap and the condensate is draining properly�
Check the air intake and vent outlet for blockage and/or debris� Ensure that condensate is disposed of per local codes and regulations�
15
CARING FOR YOUR WATER HEATER
Water Heater Inspections (cont.)
Burner
It is recommended that the burner be inspected annually by a qualified service technician�
!
DANGER:
Shock Hazard – Removing the front cover panel exposes you to live electricity. Electric shock will cause death or serious personal injury.
1
Remove 4 screws and the unit cover panel�
Burner
Glass
3
While the water heater is operating, inspect the main burner flames through the burner sight glass� The flames should be blue when the main burner is firing�
NOTICE:
If the flames are not blue or you observe unusual burner operation, shut off the water heater and contact a qualified service technician.
2
Turn on a hot water faucet�
4
Turn off the hot water faucet and reinstall the unit cover panel�
16
CARING FOR YOUR WATER HEATER
Care and Cleaning
!
DANGER:
Shock Hazard – Make certain power to the water heater is OFF before removing protective cover for any reason.
Electric shock will cause death or serious personal injury.
!
WARNING:
Combustible materials, such as clothing, cleaning materials, or flammable liquids, must not be placed against or next to the water heater. Fire or explosion can occur causing death, personal injury, and/or product damage.
All care and cleaning to and around the water heater should only be performed with the water heater turned off and the electrical power supply disconnected�
NOTICE:
The air intake requires a minimum of 12 in. (30 cm) of clearance between the air intake opening and any obstruction.
Clean the water filter monthly, as described below and on page 18�
Water Filter Cleaning
1
Turn off the water heater and disconnect the electrical power supply�
1
Vacuum around the water heater to remove any dust, dirt, and/or lint buildup�
Clean the water heater and the remote control with a
2
Turn off the water supply to the water heater�
2 damp soft cloth and mild detergent� Gently wipe and completely dry all surfaces�
Check the air intake and vent outlet for blockage and/or
Outdoor models
Drain Valve
3
Drain the water heater� See page 20�
3 debris�
17
CARING FOR YOUR WATER HEATER
Care and Cleaning (cont.)
!
CAUTION:
DO NOT tap or force the filter during removal. This can deform and/or damage the filter.
!
CAUTION:
DO NOT overtighten the water filter. Overtightening can deform and/or damage the filter.
4
Unscrew the water filter from the base of the cold water inlet line and carefully slide it out of the line�
6
Replace the filter in the cold water inlet line and tighten until it is snug�
5
Clean the water filter under running water� To remove severe sediment and dirt, use a soft brush�
7
Turn on the water supply, reconnect the electrical supply, and turn on the water heater�
18
CARING FOR YOUR WATER HEATER
Preventive Maintenance
!
WARNING:
Failure to perform routine preventive maintenance can prevent the water heater from operating properly. Improper operation can cause carbon monoxide dangers, excessive water temperatures, and other potentially hazardous conditions resulting in death, personal injury, and/or product damage.
Properly maintaining your water heater will ensure dependable, trouble-free service�
User Preventive Maintenance
Establish and follow a routine preventive maintenance program� The following suggested items should be included in your program�
17
14
15
16
NOTICE:
If the pressure relief valve on the hot water heater discharges periodically, this may indicate a problem in the water system. Contact the water supplier or a plumbing contractor to correct the problem. DO NOT plug the relief valve outlet.
22
23
24
• Monthly check and clean the water filter� See “Water
Filter Cleaning” on page 17�
!
WARNING:
Hot water is released during manual operation of the relief valve. Make sure all people and animals are clear from the area before performing this check to prevent death, personal injury, and/or property damage from hot drain water.
Annually check the operation of the pressure-relief valve�
Lifting the lever handle on the pressure-relief valve opens the valve to flush hot water through the discharge line to the drain� After several gallons have drained, release the lever handle to close the valve and stop draining�
• Inspect and keep the area around the water heater clear and free of flammable materials, such as gasoline and other flammable vapors and liquids.
• Visually inspect the water heater for damage and/ or denting. If present, contact a service personnel to verify proper operation.
• Check for abnormal sound during normal operation (e.g., hissing or banging noises).
Contact a qualified service technician or plumbing contractor.
• Check all gas and water pipes for leaks. See page 54.
NOTICE:
– DO NOT operate the water heater if you feel something is wrong with the unit.
– DO NOT allow children to operate or handle the unit.
• After inspections, maintenance, and/or cleaning, ensure proper operation by turning on a hot water faucet�
Professional Preventive Maintenance
It is recommended that a periodic inspection of the water heater burner, relief valve, air intake filter, water filter, and venting system be made by a qualified service technician�
!
WARNING:
Certain water conditions can damage the water heater and may cause defects, malfunctions or failures of the water heater that are not covered by the limited warranty. See page 46 for more detail.
19
CARING FOR YOUR WATER HEATER
Draining the Water Heater
!
WARNING:
Failure to follow these draining instructions can cause serious personal injury from scalding and/or product damage.
5
Close the water shut-off valve.
1
Turn off the water heater by pressing the POWER
ON/OFF button on the control panel.
6
Using a suitable container to catch the water, remove the water filter from the base of the cold water inlet line.
2
Close the gas shut-off valve(s).
3
At least 10 seconds after Step 1, unplug the water heater or disconnect the power supply at the circuit breaker box.
7
Connect a garden hose to the drain valve in the hot water outlet line and place the other end in a suitable drain. Open the drain valve until all the water has drained from the water heater. Leave water heater as is until placed back in service.
20
4
Open all hot water faucets. Run the water until it is
COLD; then shut off the faucet.
CARING FOR YOUR WATER HEATER
Draining the Water Heater (cont.)
!
CAUTION:
Even when drained properly, a small amount of water will remain in the water heater. In cold weather conditions, this water can freeze. If this happens, allow the defrost protection on the water heater at least 30 minutes to melt the frozen water.
The water heater will not work properly until this water is thawed.
To put the water heater back in service:
4
Open all hot water faucets and let run until all air has been purged from the lines.
1
Disconnect drain hose. Make sure the drain valve is closed.
5
Plug in the power cord or reconnect the power supply at the circuit breaker box.
2
Reinstall the water filter in the base of the cold water inlet line.
6
Open the gas shut-off valve(s).
3
Open the water shut-off valve.
7
Press the POWER ON/OFF button on the control panel to restart the unit.
21
CARING FOR YOUR WATER HEATER
Draining the Water Heater (cont.)
Preferred Drain Method
Isolator valve kits may be purchased from the manufacturer, distributor, or place of purchase� The kits include two full port isolation valves to be used in the inlet and outlet water lines� It is highly recommended to install isolator valve kits because these kits provide a means for full diagnostic testing and ease of system flushing�
Pressure
Relief Valve
Hot Water
Service Valve
Water
Outlet
Cold Water
Service Valve
Water
Inlet
Freeze Protection
!
WARNING:
Failure to drain the water heater can cause serious personal injury from scalding and/or product damage.
Whenever the water heater may be exposed to freezing conditions, make sure to completely drain the water from the unit� See page 20�
Freezing conditions come from the ventilation system on direct-vent models and from exposure to cold air on outdoor models�
All of these water heaters are equipped with a freeze protection electric heater� This heater prevents freezing inside the water heater down to an ambient temperature of approximately -30°F (-34°C)� These temperatures are all based on temperatures without wind�
The heater only protects the internal components of the water heater�
NOTICE:
Unplugging or disconnecting the power supply to the water heater will also disconnect the power to the heater.
External piping and valves require additional freeze protection� One method is to wrap insulation around the piping and valves�
Another method is to turn on a hot water faucet and leave a small amount of water running at a faucet� This will protect the water heater, piping, and valves from freezing�
Running Water Freeze Protection
1
Turn off the water heater by pressing the POWER ON/OFF button on the control panel�
2
Close the gas shut-off valve(s)�
3
Open a hot water faucet slightly until the water stream is approximately 1/8 in� (0�3 cm)� Be sure to check the flow periodically�
22
CARING FOR YOUR WATER HEATER
Vacation and Extended Shutdown
!
WARNING:
Failure to drain the water heater can cause serious personal injury from scalding and/or product damage.
If the water heater is to remain idle for an extended period of time, the power and water to the heater should be turned off�
The water heater and piping should be drained if they might be subjected to freezing temperatures� See “Freeze
Protection” section on page 22�
After an extended shutdown, the water heater’s operation and controls should be checked by a qualified service technician�
Troubleshooting Chart
The information in the following troubleshooting chart may help you diagnose and/or fix a problem you may be experiencing� Please review this chart before calling for service assistance�
!
DANGER:
Shock Hazard – Make certain power to the water heater is OFF before removing protective cover for any reason. Electric shock will cause death or serious personal injury.
Problem
Not enough or no hot water�
3 4 9 11
13
7
5 12
4 2
10
8 6
1
!
WARNING:
For Your Safety, DO NOT attempt repair of electrical wiring, gas piping remote control, burners, vent connectors, or other safety devices. Refer repairs to a qualified service technician.
Possible Cause Solution
1� Unit is not ON�
2� Water shut-off valve is not completely opened�
1� Turn on the unit by pressing the POWER
ON/OFF button�
2� Check shut-off valve and open completely�
3� Hot water faucet is not completely opened� 3� Open hot water faucet completely� (The main burner goes off when incoming water volume is inadequate�)
4� Water piping is frozen�
5� Electrical power is disconnected or water supply is shut off�
6� The temperature may be set too low�
7� Mixing valve malfunctions (if
applicable)�
4� Allow piping to thaw�
5a� Plug in the power cord or reconnect the power supply at the circuit breaker box�
5b� Completely open the water supply valve�
(Inadequate water volume will cause the main burner to turn off�)
6� Increase the temperature setting�
7� Check and replace the mixing valve�
8� Error code displayed on the remote control� 8� See “Service Error Code Chart” on page 25� If required, contact a qualified service technician�
9� Not enough water demand� 9� Increase the hot water flow at the faucet�
10� Water filter is clogged or dirty�
11� Fixture aerator is clogged or dirty�
12� Scale buildup in the heat exchanger�
13� Hot and cold water lines reversed�
10�
11�
12�
Clean the water filter� (See page 17�)
Clean the aerator�
Check for error code� If required, contact a qualified service technician�
13� Reverse the water lines�
23
CARING FOR YOUR WATER HEATER
Troubleshooting Chart (cont.)
Problem
Water not hot enough�
Possible Cause
1� The temperature may be set too low�
1
2� The gas valve is not completely opened�
3� Gas supply pressure is low�
2
Solution
1� Increase the temperature setting at the remote control�
2� Check and completely open the gas valve�
3� Contact your gas utility company or gas contractor to verify the gas meter and gas piping size�
Water too hot�
4�
1�
Bleed-over in one of the hot water fixtures�
Temperature is set too high�
4� Contact a dealer or a qualified service technician�
1� Decrease the temperature setting at the remote control�
1
2� Water shut-off valve is not completely opened�
2� Check and completely open the water shutoff valve�
3
3� Small amount of water has been heated� 3� Increase the hot water flow at the faucet to allow more water to flow through the water heater�
2
Fan continues to rotate after the hot water faucet is closed�
The post-purge cycle clears flue gases� Normal operation�
24
CARING FOR YOUR WATER HEATER
Service Error Code Chart
Your water heater has an electronic diagnostic system built into it. When the water heater finds a problem, it displays an error code in the LED display on the remote control. The following chart lists the error codes along with their possible problem and solution. Using this chart may help you diagnose and/or fix a problem you may be experiencing. Please refer to this chart before calling for service assistance.
!
DANGER:
Shock Hazard – Make certain power to the water heater is OFF before removing protective cover for any reason. Electric shock will cause death or serious personal injury.
!
WARNING:
For Your Safety, DO NOT attempt repair of electrical wiring, gas piping, remote control, burners, vent connectors, or other safety devices. Refer repairs to a qualified service technician.
3
Wait about 5 minutes; then restart the water heater by pressing the POWER ON/OFF button.
1
When an error code is displayed:
2
Turn off all the hot water faucets.
Turn off the water heater by pressing the POWER
ON/OFF button on the remote control.
4
Turn on a hot water faucet and recheck the remote control display.
If the error code remains in the display:
1�
Turn off the hot water faucet�
2�
Turn off the water heater�
3�
Unplug the water heater from power, wait about 30 seconds and plug back in�
4�
Follow the error code chart information�
5�
Restart the water heater, turn on a hot water faucet, and recheck the remote control display�
If the error code is still shown:
1�
Turn off the hot water faucet�
2�
Turn off the water heater�
3�
Make note of the displayed error code and call for service assistance� See “Call for Assistance” section on page 26�
NOTICE:
If the displayed error code is not listed in the chart, immediately turn off the water heater and call for service assistance�
25
CARING FOR YOUR WATER HEATER
Service Error Code Chart (cont.)
Error Code
1L
05
11
12
13
14
15
31
33
61 or 99
65
P1
88
Possible Cause
Water heater has buildup of lime deposits�
Air intake or vent exhaust opening may be blocked�
The vent pipes on the vent termination may not be connected properly�
The gas shut-off valve is not fully opened�
Gas service has been interrupted�
LP gas is running low (LP models only)�
If this code is still displayed after taking the numbered steps above�
Water heater is overheating�
The heat exchanger is too hot�
Solution
Contact a dealer or qualified service technician�
Remove any blockage� (Air intake requires 12 in�
[30 cm] of clearance�)
Contact a dealer or qualified service technician�
Check shut-off valve and open completely�
Contact your gas utility company�
Refill or replace your LP gas container�
Contact a dealer or qualified service technician�
Faulty inlet thermistor�
Faulty outlet thermistor�
Faulty blower motor�
Faulty water flow solenoid�
Not enough water flow to operate the unit�
Reminder of flushing the heat exchanger and/or replacing the water treatment filter�
Contact a dealer or qualified service technician�
Check for blockage in the vent� Contact a dealer or qualified service technician�
Contact a dealer or qualified service technician�
Contact a dealer or qualified service technician�
Contact a dealer or qualified service technician�
Contact a dealer or qualified service technician�
Increase the water flow from the fixtures�
Contact a dealer or qualified service technician�
26
IF YOU NEED SERVICE
Call for Assistance
1. All questions, adjustments, repairs, and/or routine maintenance should be directed to your installer, plumbing contractor, or licensed service agent. If your contacts have moved or are not available, please refer to the telephone directory, commercial listings, or local utility company for qualified service assistance.
2. If your problem has not been solved to your satisfaction, contact the Rheem National Service
Department at the following address:
Rheem
National Service Department
1241 Carwood Court
Montgomery, Alabama 36117
Phone: 1-866-720-2076
When contacting the manufacturer, the following information will be requested:
A. Model and serial number. (See page 8 or the ratings plate on the side of the water heater.)
B. Address where the water heater is located.
C. Name and address of installation contractors
(page 8) and all qualified service companies that have worked on the water heater.
D. Original installation date. (See page 8.)
E. Dates any service or preventive maintenance was performed.
F. Details of the persisting problem.
G. List of businesses that have tried to fix this problem, along with dates of service.
INSTALLATION
INSTRUCTIONS
FOR THE CONTRACTOR
INSTALLATION INSTRUCTIONS
Standards Compliance
This water heater must be installed in accordance with these instructions, local codes, and utility company requirements.
In the United States where local codes are not available, use the latest edition of the American
National Standard/National Fuel Gas Code. A copy of the Fuel Gas Code can be purchased from either the American Gas Association, 400
North Capitol Street Northwest, Washington, DC
Choosing a Location
WARNING:
Fire Hazard – Combustible construction refers to adjacent walls and ceilings and should not be confused with combustible or flammable products and materials. Combustible materials, such as clothing, cleaning materials, or flammable liquids, must not be placed against or next to the water heater. Fire or explosion could occur causing death, personal injury, and/or product damage.
A gas-fired water heater should never be installed in a space or room where liquids with flammable vapors are used or stored. Such liquids include gasoline, LP gas (butane or propane), paint, adhesives and their thinners, solvents, or removers.
Flammable vapors carry long distances from where they are used or stored. The open flame of the water heater’s main burner can ignite these vapors causing an explosion or fire.
NOTICE:
Elevating a gas-fired water heater will reduce but
NOT eliminate the possibility of lighting the vapor of flammable liquids which may be improperly stored or accidentally spilled.
20001, as ANSI standard Z223.1, or National Fire
Protection Association, 1 Batterymarch Park, MA
02269 as NFPA 54.
In Canada, use the latest edition of the CAN/
CSA B149.1 Natural Gas and Propane Installation
Code and the Canadian Electrical Code, CAN/CSA
C22.1, Part 1.
NOTICE:
This water heater should not be located in an area where leakage of the heat exchanger or connections will result in damage to the area adjacent to it or to lower floors of the structures.
When such areas cannot be avoided, install a suitable catch pan with an adequate drain under the water heater. This drain pan must not restrict the combustion airflow.
The following requirements will ensure a safe installation:
The water heater must be located in an area where it won’t sustain damage from moving vehicles, flooding, etc. If the water heater is installed in a storage garage, the direct ignition system and main burner should be no less than 18 in. (45 cm) above the garage floor.
If the water heater is installed in a repair garage or in a private garage, the direct ignition system and main burner should be no less than 4.5 ft. (1400 mm) above the garage floor.
The water heater should be installed as close as possible to the vent termination. This minimizes the vent length and the number of elbows and joints required for venting.
The water heater should be installed with the proper venting and exhaust materials suitable for
Category III venting.
0" min.
(0 mm)
0" min.
(0 mm)
0" min.
(0 mm)
Coaxial Vent Pipe and Air Intake
28
INSTALLATION INSTRUCTIONS
Choosing a Location (cont.)
12" min.
(300 mm)
1/2" min.
(13 mm)
Every vent pipe penetration of a floor or ceiling that is not in a fire-rated shaft requires a fire stop plate.
Failure to install and properly vent the water heater to the outdoors as outlined on pages 34 through 45 can result in unsafe operation.
Minimum water heater clearances from combustible and noncombustible construction are as follows:
– 1/2 in. (1.3 cm) for sides
– 0 in. (0 cm) for rear with support bracket(s)
– 12 in. (30 cm) from the bottom, top, and front
NOTICE:
Preferred maintenance clearance is 24 in. (61 cm) from top, bottom, and front of unit.
0" min.
(0 mm)
Long hot water lines should be insulated to conserve water and energy.
The water heater and water lines should be protected from exposure to freezing temperatures.
• DO NOT install the water heater in
Code in U�S� installation or CAN/CSA
B149�1 in Canada installation�
• DO NOT install the water heater where
Minimum clearance around the coaxial vent pipe should meet the specifications listed on the instruction/warning label on the water heater� If no label is found, use the vent manufacturer’s specifications or a minimum clearance of 0 in� (0 cm) around the vent pipe�
• DO NOT install the water heater in a or other watercraft�
• DO NOT install the water heater
If necessary, maintain a minimum clearance of 4 ft� (1�2 m)�
29
INSTALLATION INSTRUCTIONS
Product Inspection
Visually inspect the water heater for any possible damage.
Check the rating plate on the water heater to make sure the water heater was designed to be used with the supplied type of gas (natural or LP).
Verify that all included supplied parts are present as shown.
Remote Control
Screws
Washers
Remote Control Cable
30
Manual Gas Shut-Off Valve
Water Heater Installation
Corrosive Atmosphere
NOTICE:
The water heater should not be installed near an air supply containing halogenated hydrocarbons.
Avoid installing a water heater in any of the following locations: beauty shops, dry-cleaning establishments, photo processing labs, and storage areas for liquid and powdered bleaches or swimming pool chemicals� These locations often contain such halogenated hydrocarbons�
The air supply containing halogenated hydrocarbons is
Pressure Relief Valve
(Some models only) safe to breathe, but when passed through a gas flame, corrosive elements are released that will shorten the life of any gas-burning appliance�
Propellants from common spray cans or gas leaks from
A/C and refrigeration equipment are highly corrosive after passing through a flame�
NOTICE:
The water heater warranty is void when the failure is due to operation in corrosive conditions.
INSTALLATION INSTRUCTIONS
Water Heater Installation (cont.)
NOTICE:
The National Fuel Gas Code (NFGC) and CAN/CSA B149.1 mandate a manual gas shut-off valve. See NFGC/B149.1 for complete instructions. Local codes or plumbing authority requirements may vary from the instructions or diagrams provided and take precedence over these instructions.
Typical Installation of Direct-Vent Water Heater (Venting Required)
Wall
Plate
1/4" Per Foot Downward Slope
(recommended)
90˚
Elbow
Vent Termination
With Protective
Screen
Built In Condensate Collector
Condensate Trap
To Drain: Dispose of condensate in accordance to local codes.
To Hot Water
Faucet(s)
Drain Valve
Power
Supply
Cord
Union
Water
Filter
Relief
Valve
Manual Gas
Shut-Off Valve
Union
Service
Valve
Sediment Trap
Cap
Cold Water Supply
Shut-Off Valve
6"
(150 mm)
Air Gap
Discharge Line
(To Suitable Drain)
Manual Gas
Supply Line
Shut-Off Valve
Outside
Wall
31
INSTALLATION INSTRUCTIONS
Water Heater Installation (cont.)
Typical Installation of Outdoor Water
Heater (No Venting Required)
This water heater is for OUTDOOR installation only.
!
WARNING:
DO NOT install this water heater indoors or in a confined area. It is designed for outdoor installation only. Any other type of installation can result in death, personal injury, and/or damage to the product or property.
Flue
Terminal
32
Hard-Wire
Union
To Hot Water
Faucet(s)
Relief
Valve
Drain Valve
(150 mm)
Air Gap
Union
Sediment Trap
Cap
Supply Line
Shut-Off Valve
Alternate Water Piping Arrangement
With Preferred Valve Kit
A valve kit is available and can be used with all models�
See “Water Supply Connections” on page 46 for installation instructions�
Pressure
Relief Valve
Hot Water
Service Valve
Water
Outlet
Cold Water
Service Valve
Water
Inlet
INSTALLATION INSTRUCTIONS
Mounting the Water Heater
!
CAUTION
Reinforcement of the wall is required in case the wall is not strong enough to hold the water heater.
Failure to do so could result in personal injury and/ or product damage.
The mounting location for the water heater should allow for easy access and operation�
1
The water heater is designed to be installed either inside the wall cavity between the wall studs or outside the wall cavity� Either installation requires the water heater to be supported with a wooden support brace between the wall studs or a piece of wood that is equal in size to the water heater and securely attached to the wall studs before the water heater is attached to it� This piece of wood can be installed inside or outside the wall� Use wood screws to secure brackets to the wall� If mounting to a concrete wall, use lag bolts designed for concrete�
3
Position the upper mounting bracket and partially install the center mounting screw� The clearance between the screw head and the wall should be about 1/8 in� (0�3 cm)�
Hang the upper bracket on the screw�
NOTICE:
The image above may differ in appearance from your water heater.
4
Using two mounting screws and washers, secure the lower mounting bracket to the wall� Then, secure the upper mounting bracket to the wall with two mounting screws and washers�
2
Make sure the proper electrical outlet or supply (120
VAC/60 Hz) is available and located near the unit� Directvent models come with a 6-ft� (1�8-m) power cord, while the outdoor models require hard-wiring or the addition of a plug�
5
Position the water heater and tighten the adjustment screws to complete the installation� The rear of the water heater can be positioned anywhere between 3/8 in� (0�95 cm) and 1 1/2 in� (3�8 cm) from the wall (indoor model only)�
33
INSTALLATION INSTRUCTIONS
Venting for Direct-Vent Water Heater
The water heater must be installed with 3-in�/5-in�
(7�6-cm/12�7-cm) diameter UL-approved Category III
Coaxial Stainless Steel appliance vent pipe or water heater manufacturer-approved concentric vent pipe�
!
DANGER:
Failure to install and properly vent the water heater to the outdoors as outlined in this Venting section will result in death or serious personal injury. To avoid the risk of fire, explosion, or asphyxiation from carbon monoxide, NEVER operate the water heater unless it is properly vented and has adequate air supply for proper operation as outlined in this Venting section.
!
WARNINGS:
• Use 3-in./5-in. (7.6-cm/12.7-cm) UL-approved
Category III Stainless Steel vent materials or water heater manufacturer-approved vent material. No other vent material is permitted for use with this appliance.
• Refer to page 29 for required clearances to combustible materials. Improper clearances can cause explosion or fire resulting in death, personal injury, and/or product damage.
Venting Requirements
The installation of venting must comply with national codes, local codes, and the vent manufacturer’s instructions�
The water heater must be vented to the outdoors as described in these instructions� DO NOT vent this water heater through a chimney� It must be vented separately from all other appliances�
All inner coaxial vent components (adapters, pipe, elbows, terminals, etc�) should be water heater manufacturer-approved Stainless Steel Venting Material
(e�g�, 444 SS, 316 L)�
Outer casing can be galvanized aluminum or other material�
The specified vent termination must be used� (Refer to page 45 for an example of concentric vent�)
!
CAUTION:
DO NOT attempt to fabricate or adapt other vent pipe or materials to this venting.
Use the provided screws to connect the coaxial vent pipe together�
Follow the vent manufacturer’s installation instructions�
This water heater can be vented horizontally or vertically�
All coaxial vent piping runs must be adequately supported� The maximum recommended unsupported span should be no more than 4 ft� (1�2 m)� Only use support isolation hanging bands� DO NOT use wire to support pipe runs�
Preexisting Venting Notes:
If the water heater is being installed as a replacement for an existing water heater, a thorough inspection of the existing venting and air intake system must be performed prior to any installation work. Verify that the correct materials, vent lengths, and terminal locations as described in this manual have been met. Carefully inspect the entire venting and air intake system for any signs of cracks or fractures, particularly at the joints between elbows or other fittings and the straight runs of vent pipe. Check the system for signs of sagging or other stresses in the joints as a result of misalignment of any components in the system. If any of these conditions are found, they must be corrected in accordance with the venting instructions in this manual before completing the installation and putting the water heater into service.
See page 35 for additional requirements for the
Commonwealth of Massachusetts�
34
INSTALLATION INSTRUCTIONS
In the Commonwealth of Massachusetts
The Commonwealth of Massachusetts requires compliance with regulation 248 CMR 4�00 and 5�00 for installation of throughthe-wall vented gas appliances as follows:
5�08: Modifications to NFPA–54, Chapter 10
(1) Revise NFPA–54 section 10�5�4�2 by adding a second exception as follows:
Existing chimneys shall be permitted to have their use continued when a gas conversion burner is installed, and shall be equipped with a manual reset device that will automatically shut off the gas to the burner in the event of a sustained backdraft�
(2) Revise 10�8�3 by adding the following additional requirements:
(a) For all side-wall, horizontally vented, gas-fueled equipment installed in every dwelling, building, or structure used in whole or part for residential purposes, including those owned or operated by the Commonwealth and where the side-wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied�
1� INSTALLATION OF CARBON MONOXIDE DETECTORS� At the time of installation of the side-wall, horizontally vented, gas-fueled equipment, the installing plumber or gasfitter shall observe that a hard-wired carbon monoxide detector with an alarm and battery backup is installed on the floor level where the gas equipment is to be installed� In addition, the installing plumber or gasfitter shall observe that a battery-operated or hard-wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building, or structure served by the side-wall, horizontally vented, gas-fueled equipment� It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard-wired carbon monoxide detectors� a� In the event that the side-wall, horizontally vented, gas-fueled equipment is installed in a crawl space or an attic, the hardwired carbon monoxide detector with alarm and battery backup may be installed on the next adjacent floor level� b� In the event that the requirements of this subdivision cannot be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements, provided, however, that during said thirty (30) day period, a battery-operated carbon monoxide detector with an alarm shall be installed�
2� APPROVED CARBON MONOXIDE DETECTORS� Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL
2034-listed and IAS-certified�
3� SIGNAGE� A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented, gasfueled heating appliance or equipment� The sign shall read, in print size no less than one-half (1/2) inch in size, “GAS VENT
DIRECTLY BELOW� KEEP CLEAR OF ALL OBSTRUCTIONS�”
4� INSPECTION� The state or local gas inspector of the sidewall, horizontally vented, gas-fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5�08 (2)(a)(1 through 4)�
(b) EXEMPTIONS: The following equipment is exempt from 248
CMR 5�08 (2)(a)(1 through 4):
1� The equipment listed in Chapter 10 entitled “Equipment Not
Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board, and
2� Product-approved side-wall, horizontally vented, gas-fueled equipment installed in a room or structure separate from the dwelling, building, or structure used in whole or in part for residential purposes�
(c) MANUFACTURER REQUIREMENTS – GAS EQUIPMENT
VENTING SYSTEM PROVIDED� When the manufacturer of product-approved side-wall, horizontally vented, gas-fueled equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:
1� Detailed instructions for the installation of the venting system design or the venting system components; and
2� A complete parts list for the venting system design or venting system�
(d) MANUFACTURER REQUIREMENTS – GAS EQUIPMENT
VENTING SYSTEM NOT PROVIDED� When the manufacturer of product-approved side-wall, horizontally vented, gas-fueled equipment does not provide the parts for venting the flue gases, but identifies “special venting systems,” the following requirements shall be satisfied by the manufacturer:
1� The referenced “special venting systems” instructions shall be included with the appliance or equipment installation instructions, and
2� The “special venting systems” shall be product-approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions�
(e) A copy of all installation instructions for all productapproved side-wall, horizontally vented, gas-fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation�
35
INSTALLATION INSTRUCTIONS
Venting for Direct-Vent Water Heater (cont.)
36
90˚
Elbow
Vent Pipe Wall Plate
Fire
Stop
Recommended Vent Lengths
Number of 90°
Elbows (bends)
1
2
5
6
3
4
Maximum Length of Straight Pipe
39 ft� (12�0 m)
37 ft� 6 in� (11�5 m)
36 ft� (11�0 m)
34 ft� 6 in� (10�5 m)
33 ft� (10�0 m)
31 ft� 6 in� (9�5 m)
Maximum Vent Length:
The system will not operate if there is excessive restriction (pressure drop) in the venting system� Use the chart above to calculate the maximum pipe run length with the required number of elbows (e�g�, a maximum
39 ft� [12 m] of vent pipe may be used provided there is only one 90° elbow in the system)�
A 90° elbow is equivalent to 1 ft� 6 in� (0�5 m) of straight pipe, while a 45° elbow is equivalent to 9 in� (0�25 m) of straight pipe�
The vent termination does not count as part of the straight pipe equivalent when determining the total vent length� The vent pipe should be installed with a slight downward slope of 1/4 in� per foot of horizontal run toward the vent termination� This ensures that any condensate formed during operation is evacuated from the water heater� It also prevents rain from entering the appliance� An upward slope on the vent termination is not acceptable for horizontal venting without using the condensate collector�
Inspection
(Optional)
Ceiling
Minimum Vent Length:
The venting may be as short as 12 in� (30 cm), provided one vent termination is installed to the outdoors through a sidewall with one 90° elbow and one wall plate included in the installation� Total equivalent vent length is 30 in�
(76 cm)�
Vent Seam
NOTICE:
Inspection
(Optional)
Make sure that the seam of the inner vent pipe in a horizontal run is towards the top of the installation as shown above.
Venting Through Closed Spaces
If the coaxial vent piping passes through a closed space, a minimum clearance of 0 in. (0 cm) for vertical piping and for horizontal piping should be maintained between the coaxial vent pipe and combustibles and noncombustibles. Be sure to follow local codes and vent manufacturer’s installation instructions.
For maintenance and inspection purposes, the following access panels may be required.
Two (2) inspection access panels large enough to allow access for venting inspection. One access panel may be close to where the coaxial vent pipe enters the ceiling. The other access panel may be near the vent termination.
INSTALLATION INSTRUCTIONS
Appliance Vent Adapter
!
CAUTION:
Ensure that the appliance vent adapter is securely attached to the water heater collar. Improperly connected vent adapter can cause damage to the appliance and/or poor performance.
Metal Fab Inc� standard concentric vent pipe can be installed into the water heater collar without an appliance vent adapter� However, other Rheem-approved vent manufacturer's pipe cannot be installed without a
UL-approved Category III Stainless Steel appliance concentric vent adapter�
NOTICE:
To install the appliance vent adapter, please follow the appliance vent adapter manufacturer's instructions.
Draining Vent Condensate
!
WARNINGS:
Failure to provide a vent condensate drain close to the water heater could allow acidic flue gas condensate to enter into water heater flueways, causing premature failure of the water heater.
If the condensate collector is not used, the drain fitting must be capped to prevent exhaust gases and condensate from entering the building� The cap is supplied on the water heater�
!
CAUTIONS:
Condensate is known to be acidic; refer to federal, state (provincial), and local codes for proper handling and discharge methods.
Condensate must be drained away from the water heater and should not be allowed to drain back into any part of the vent system.
The condensate collector must be used with vertical vent installation.
Condensate collector must be used with horizontal vent installation if the vent has an UPWARD slope toward the termination.
Provision should be made to collect and dispose of condensate from the venting systems.
When a water heater is vented horizontally, the vent pipe should have a DOWNWARD or UPWARD slope towards the termination. If an UPWARD slope is used, always attach a drain hose to the condensate collector and plumb the hose to a sanitary sewer drain.
Upward Slope
When a water heater is vented vertically, an
UPWARD slope must always be used. Always attach a drain hose to the condensate collector and plumb the hose to a sanitary sewer drain.
Properly installed condensate traps prevent the condensate from draining back into the water heater.
A high-temperature silicone tubing suitable for use with acidic condensate and appropriate for the temperature range should be used.
Condensate Collector
Condensate Trap
The drain tube is fashioned into a “pigtail” trap and must be filled with water to prevent flue gases from emitting into the building prior to operating the water heater.
37
INSTALLATION INSTRUCTIONS
Venting for Direct-Vent Water Heater (cont.)
Horizontal Vent Terminal Location
Outside Walls
D
F
V
C
V
Fixed
Closed
Operable
B
B
B
V Operable
Fixed
Closed
V
V
X
A J
H
I
V
E
L
V
B
V
X
Vent Terminal
Air Supply Inlet
Area Where Terminal is Not Permitted
Inside Wall
G
V
A
V
K
X
38
INSTALLATION INSTRUCTIONS
Horizontal Vent Terminal Location (cont.)
The following chart details the minimal dimensional information needed to determine the proper location of the vent terminal for direct vent and outdoor tankless water heaters� See corresponding letter reference in the illustration on page
38�
Location U.S. Installation Requirements 1 Canadian Installation Requirements 2
A = Clearance above grade, veranda, porch, deck, or balcony�
B = Clearance to window or door that may be opened�
12 in� (30 cm) 12 in� (30 cm)
C = Clearance to permanently closed window�
• 6 in� (15 cm) for water heaters less than or equal to 10,000 Btuh (3 kW)�
• 9 in� (23 cm) for water heaters greater than
10,000 Btuh (3 kW) and less than or equal to 50,000 Btuh (15 kW)�
• 12 in� (30 cm) for water heaters greater than 50,000 Btuh (15 kW) 3 �
• 6 in� (15 cm) for water heaters less than or equal to 10,000 Btuh (3 kW)�
• 12 in� (30 cm) for water heaters greater than 10,000 Btuh (3 kW) and less than or equal to 100,000 Btuh (30 kW)�
• 36 in� (91 cm) for water heaters greater than 100,000 Btuh (30 kW)�
D = Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 ft� (61 cm) from the centerline of the terminal�
E = Clearance to unventilated soffit�
36 in (91 cm) recommended 4
36 in (91 cm) recommended 4
F = Clearance to outside corner�
G = Clearance to inside corner�
36 in (91 cm) recommended 4
18 in (46 cm) recommended 4
36 in (91 cm) recommended 4
18 in (46 cm) recommended 4
3 ft� (91 cm) within a height of 15 ft� (4�57 m) above the meter/regulator assembly�
H = Clearance to each side of centerline extended above meter/regulator assembly�
I = Clearance to service regulator vent outlet�
J = Clearance to nonmechanical air supply inlet to the combustion air inlet to any building or other appliance�
K = Clearance to mechanical air supply inlet�
• 6 in� (15 cm) for water heaters less than or equal to 10,000 Btuh (3 kW)�
• 9 in� (23 cm) for water heaters greater than
10,000 Btuh (3 kW) and less than or equal to 50,000 Btuh (15 kW)�
• 12 in� (30 cm) for water heaters greater than 50,000 Btuh (15 kW) 3 �
3 ft� (91 cm) above if within 10 ft� (3 m) horizontally�
3 ft� (91 cm)
• 6 in� (15 cm) for water heaters less than or equal to 10,000 Btuh (3 kW)�
• 12 in� (30 cm) for water heaters greater than 10,000 Btuh (3 kW) and less than or equal to 100,000 Btuh (30 kW)�
• 36 in� (91 cm) for water heaters greater than 100,000 Btuh (30 kW)�
6 ft� (1�83 m)
L = Clearance above paved sidewalk or paved driveway located on public property�
M = Clearance under veranda, porch, deck, or balcony�
7 ft� (2�13 m) †
12 in� (30 cm) ‡
1 In accordance with current ANSI Z223�1/NFPA 54 National Fuel Gas Code�
2 In accordance with current CAN/CSA B149�1 Installation Codes�
3 For outdoor model, 4 ft (1�2 m) below or to side of opening; 1 ft (300 mm) above opening�
4 These are recommended minimum distances to prevent exhaust gas recirculation which may cause operational issues with the appliance�
For clearances not specified in ANSI Z223�1/NFPA 54 or CAN/CSA B149�1, one of the following shall be indicated: a) A minimum clearance value determined by testing in accordance with section 2�20, or b) A reference to the following footnote: “Clearance in accordance with local installation codes and the requirements of the gas supplier�”
† A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single-family dwellings and serves both dwellings�
‡ Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor�
39
INSTALLATION INSTRUCTIONS
Venting for Direct-Vent Water Heater (cont.)
Horizontal Vent Considerations
!
WARNING:
Moisture in the flue gas will condense as it leaves the vent terminal. In cold weather this condensate can freeze on the exterior wall, under the eaves, and on surrounding objects. Some discoloration to the exterior of the building is to be expected.
However, improper location or installation can result in severe damage to the structure or exterior finish of the building.
–
DO NOT locate vent terminal on the side of a building with prevailing winter winds. This will help prevent water lines from freezing and moisture from freezing on walls and under eaves.
–
DO NOT locate vent terminal too close to shrubbery, since flue gases may damage them.
–
All painted surfaces should be primed to lessen the chance of physical damage.
Painted surfaces will require maintenance.
–
Guard against accidental contact with people and pets.
Indoor Tankless Water Heaters
!
WARNING:
For multiple-unit installation, a minimum distance between vent terminations must be maintained to prevent recirculation of vent gases. Maintain a horizontal center-to-center distance between vent terminations of 19 in. (48 cm) for two-unit installation, or 21 in. (53 cm) for installation of three or more units*.
Caulk
Rising moisture will collect under eaves.
Inside
Corner
Caulk block off and install new vent at another location.
to edge of window etc., starting within 6' (1.8 m)
Caulk
Caulk
DO NOT terminate vent directly on brick or masonry surfaces. A rust-resistant, sheet-metal backing plate is recommended behind the vent.
–
Caulk all cracks, seams, and joints within
6 ft. (1.8 m) of the vent terminal.
–
Caulk around wall faceplate for weather-tight seal.
–
DO NOT extend exposed vent pipe of indoor water heaters outside of the building.
–
This water heater requires its own separate venting system. DO NOT connect the exhaust vent to an existing vent pipe or chimney.
Outdoor Tankless Water Heaters
Inside
Corner
Caulk
Caulk
Rising moisture will collect under eaves.
block off and install new vent at another location.
or to edge of window
6' (1.8 m)
Caulk minimum 19 in� (48cm)
– Install outdoor water heater such that air inlet and flue outlet are above anticipated snow level�
40
minimum 21 in� (53cm)
*Vents cannot be stacked vertically.
INSTALLATION INSTRUCTIONS
Horizontal Vent Installation
!
WARNING:
Follow the vent manufacturer’s installation instructions since design might vary from manufacturer to manufacturer. Improper vent installation can result in death, personal injury, product damage, and/or poor performance.
!
CAUTION:
Use UL-approved Category III Stainless Steel vent material only. No other vent material is permitted for use with this appliance.
Outer casing can be galvanized aluminum or other material�
Fasteners will vary depending on the wall type�
For particle board or composite sheathing, use 4 hollow wall anchors. The anchors should be at least
1/8 in. (0.3 cm) in diameter and the appropriate length for the sheathing thickness.
1
Apply high temperature silicone sealant or silicone/ latex caulk around the vent section. Completely seal where it passes through the wall plate and where it is attached to the structure. This will provide a weather seal for the system, so it must be a good seal.
For plywood or solid wood sheathing or members, use
4 #10 x 1 1/4-in. wood screws.
For masonry walls, use suitable masonry anchors long enough to pass through the wall.
2
Attach the female end of the next vent pipe section to the male end of the 3-in./5-in. (7.6-cm/12.7-cm) concentric vent pipe. Push firmly on the pipe until the outer jacket has made contact with the snap ring on the male end of the concentric vent pipe section. Secure the two pipe sections with the provided self-tapping screws.
NOTICE:
When fully assembled, the outer female end will overlap the male end about 1 in. (2.5 cm).
DO NOT attempt to fabricate or adapt other vent pipe or materials to this venting.
Reinstall the decorative sheathing around the faceplate. The decorative sheathing may be painted to match the exterior decor.
41
INSTALLATION INSTRUCTIONS
Venting for Direct-Vent Water Heater (cont.)
Horizontal Vent Installation (cont.)
Using a thick bead of high temperature silicone, seal the overlapping area of the outer 5-in. (12.7cm) pipe.
Typical Horizontal Termination with
1/4 In. Per Foot of DOWNWARD Slope
1/4" Per Foot Downward Slope
3
Attach required vent sections between the water heater collar and the horizontal vent termination.
2' max.*
(610 mm)
90˚
Elbow
Vent Pipe Wall Plate
Fire
Stop
Inspection
Access Panel
(Optional)
Ceiling Inspection
Access Panel
(Optional)
!
CAUTION:
The condensate collector must be used in horizontal terminations if vertical rise in the vent system exceeds 2 feet (610 mm).*
NOTICES:
• Maintain the proper clearance between the vent pipe and combustible or noncombustible materials as described on page 29.
• A zero clearance of 0 in. (0 cm) is allowed between the air intake pipes and combustible material.
• Use proper support for the vent and air intake pipes as described on page 34.
• Support method used should isolate the vent pipe from floor joists or other structural members. This helps prevent transmission of noise and vibration.
• DO NOT support, pin, or secure the venting system in a way that restricts the normal thermal expansion and contraction of the chosen venting material.
42
INSTALLATION INSTRUCTIONS
Vertical Vent Installation
!
WARNING:
Follow the vent manufacturer’s installation instructions since design might vary from manufacturer to manufacturer. Improper vent installation can result in death, personal injury, product damage, and/or poor performance.
NOTICE:
Only Rheem-approved termination and parts should be used during installation.
Install a fire stop plate at every penetration of a floor or ceiling, whenever the vent is not running through a fire-rated shaft.
Maintain the recommended air space clearance to combustible materials and building insulation.
Hole
Through Roof
CL
3
Support vertical and horizontal runs as described on page 36. Vertical supports are required every
4 ft. (1.2 m) along a vertical pipe route, after every transition to vertical, and after every offset elbow.
NOTICE:
Free-standing vent pipe that penetrates a roof/ ceiling requires another means of support from a second location.
A, B, C, D
1
Cut a hole through the roof and interior ceiling to accommodate the vent pipe.
4
Determine the vent terminal height and install the vent pipe accordingly. Refer to “Vertical Vent
Terminal Location” on page 44 for clearance requirements.
2
Complete the vent pipe installation to the water heater vent collar. If required, use high temperature silicone sealant where the vent connector joins the water heater.
5
Install adequate flashing where the vent pipe passes through the roof.
43
INSTALLATION INSTRUCTIONS
Venting for Direct-Vent Water Heater (cont.)
Vertical Vent Terminal Location
A, B, C, D
The following chart with diagrams details the minimum dimensional information needed to determine the proper location of the vertical vent terminal for direct-vent indoor tankless water heaters:
Location
A = Minimum clearance above the roof level�
B = Minimum clearance above anticipated snow level�
U�S� Installation
Requirements 1
12 in� (30�5 cm) above roof level�
12 in� (30�5 cm) above anticipated snow level�
Canadian Installation
Requirements 2
18 in� (45�7 cm) above roof level�
12 in� (30�5 cm) above anticipated snow level�
C = Maximum clearance above roof level (without additional vent support)�
D = Maximum clearance above anticipated snow level
(requires additional vent support)�
E = Required vent clearance from any gable, dormer, or other roof structure with building access (i�e�, vent, window)�
F = Required vent clearance from any forced air inlet, including dryer and furnace air inlets�
24 in� (61 cm) above roof level�
24 in� (61 cm) above anticipated snow level�
4 ft� (1�2 m)�
10 ft� (3 m)
24 in� (61 cm) above roof level�
24 in� (61 cm) above anticipated snow level�
4 ft� (1�2 m)�
6 ft� (1�8 m)
1 In accordance with current ANSI Z223�1/NFPA 54 National Fuel Gas Code�
2 In accordance with current CAN/CSA B149�1 Installation Codes�
NOTICE:
Only manufacturer-approved termination and parts should be used during installation.
44
Standard Vertical Vent Termination
INSTALLATION INSTRUCTIONS
Vertical Termination Adapter
Air Intake
Storm Collar
Adjustable Roof Flashing
3" to 5" Concentric Pipe
Support Clamp
Fire Stop
1/4" Per Foot Upward Slope
Support Hanger
CAUTION:
The condensate collector must be used with vertical vent installation.
Fire Stop
Condensate Trap of condensate in local codes.
45
INSTALLATION INSTRUCTIONS
Water Quality
Water quality must be taken into account when installing and maintaining the water heater. Water conditions outside of the levels specified below affect and may damage the water heater. Please note that the limited warranty provided with the water heater does not cover defects, malfunctions or failures resulting from water conditions that are not in accordance with the specifications in the table below.
If you nonetheless install this water heater where the water conditions are not within the levels specified in the table below, Rheem recommends that you take the following steps:
• Install a water treatment device or water softener at the same time as the original installation of the water heater. Rheem offers a water treatment accessory that can be installed with the water heater. (See below).
• Flush the water heater’s heat exchanger regularly.
Rheem offers a flush kit and isolation valves to help remove scale build up. (See below)
Chart for Recommended Water Quality Levels pH
(Total Dissolved
Solids) TDS
Free Carbon
Dioxide (CO
2
)
Total
Hardness
6�5–8�5 Up to 500 mg/L Up to 15 mg/L
Up to
200 mg/L
Cited reference: National Secondary Drinking Water Regulations
Aluminum Chlorides
0�05 to
0�2 mg/L
Up to
250 mg/L
Copper
Up to
1�0 mg/L
Iron
Up to
0�3 mg/L
Manganese
Up to
0�05 mg/L
Accessory part numbers listed below� See Parts and Accessories Catalog for more information�
Zinc
Up to
5 mg/L
Tankless Flush Kit Tankless Isolation Valve Accessory Kit Replacement Filter
AllClear Water Treatment Kit RTG20251
Scale Prevention Device RTG20246
RTG20252
RTG20247
RTG20124 RTG20220AB
Water Supply
!
CAUTION:
This water heater MUST ONLY be used with the following water supply conditions to prevent product damage and operation failure.
Clean, potable water free of corrosive chemicals, sand, dirt, or other contaminates�
Inlet water temperatures above 32°F (0°C), but not exceeding 120°F (49°C)�
DO NOT reverse the HOT and COLD water connections�
DO NOT connect this heater to water lines previously used for space heating� All water piping and components shall be suitable for potable water�
With recommended water quality (See chart above)�
Thermal Expansion
A thermal expansion tank will be required if the water heater is installed in a system with a recirculation or storage tank. This prevents damage to the heater, related piping, and the relief valve.
NOTICE:
Replacing the relief valve will not correct the problem!
The expansion tank is designed with a built-in air cushion that compresses as the system pressure increases. This relieves the over-pressure condition and eliminates the repeat operation of the relief valve.
For other approved methods of thermal expansion, contact an installing contractor, water supplier, or plumbing inspector.
Water Supply Connections
!
CAUTION:
IMPORTANT—DO NOT apply heat to the HOT or
COLD water connections. If sweat connections are used, sweat tubing to the adapter before fitting the adapter to the water connections on the water heater. Any heat applied to the water supply fittings will permanently damage the internal components of the water heater.
NOTICE:
In cold environments, ice can accumulate in the water heater’s connectors. Plug in the water heater power cord for approximately 10 minutes before making these connections. This will melt any ice buildup.
Plumbing should be carried out by a qualified plumbing contractor in accordance with local codes.
Only use approved plumbing materials.
To allow the full flow capacity, it is recommended to keep water inlet and outlet pipes 3/4-in. (1.9-cm) diameter or larger.
To conserve energy and to prevent freezing, insulate both COLD and HOT water supply lines.
DO NOT insulate the pressure-relief valve.
46
INSTALLATION INSTRUCTIONS
Water Supply Connections (cont.)
Recirculation
Direct recirculation is allowed, provided the loop is thermostatically controlled, and a timer is used to turn the pump off during off peak periods. The pump must be sized for a minimum of 5 gpm at
25 ft of head plus building head. A 10°F difference between the loop thermostat setting and water heater temperature setting must be maintained.
To ensure proper operation of the water heater, follow these water pressure guidelines.
Operation of the water heater requires a minimum water pressure of 14 psi (97 kPa) and a minimum activation water flow rate of 0.4 gpm (1.5 lpm).
Continuous operation of the water heater requires a minimum water flow rate of 0.25 gpm (1.01 lpm).
Water pressure of 40 psi (276 kPa) is required to achieve maximum flow rate.
To maintain proper performance, there must be sufficient water supply pressure.
Water Supply Installation
NOTICE:
• Use only Teflon tape on all COLD and HOT water connections.
• If the water flow resistance of a showerhead is too high, the burner in the water heater will fail to ignite. Keep all showerheads clean from debris that could cause additional pressure drop.
• If using mixing valves on the outlet, choose one that prevents COLD water pressure from overcoming HOT water pressure.
• If multiple water heaters are installed in a manifold system, the water piping MUST be in
“parallel” and the water pressure at each water heater should be 40 psi (276 kPa).
Required Water Pressure =
Min. Operating Water Pressure
(14 psi [97 kPa])
+ Pipe Pressure Loss
+ Faucet Pressure Loss
+ Safety Margin
(more than 5 psi [34 kPa]).
To supply HOT water to upper floors, additional water pressure will be required (0.44 psi [3 kPa] per foot of height). Calculate the distance between the water inlet of the water heater (ground level) to the HOT water faucet farthest away from the water heater (upper floor level).
• Well water systems should be set to ensure a minimum system pressure of 40 psi (276 kPa).
The pressure should remain constant and stable during the operation of the water heater.
• Gravity water pressure is not recommended.
When the water is supplied from a water supply tank, the height of the tank, the diameter of the supply pipes, and their relation to water pressure need to be taken into consideration.
NOTICE:
It is not recommended to use pipes with smaller diameters than the water supply connection of the water heater.
2
Before attaching the water line to the water heater, open the shut-off valve. Run the water until it has purged all contaminants (sand, debris, air, caulking).
1
Install a COLD water shut-off valve near the inlet line on the water heater. This valve will be used for servicing and draining purposes.
3
Install a service valve on the end of the COLD water supply line and connect it to the water inlet on the water heater.
47
INSTALLATION INSTRUCTIONS
Water Supply (cont.)
4
Open the drain valve in the COLD water outlet line to check the water flow through the water heater.
NOTICE:
Be sure to connect the COLD water inlet and the
HOT water outlet as shown on the water heater. If reversed, the water heater will not function.
The flow rate of HOT water may vary when more than two faucets (appliances, fixtures, etc.) are being used simultaneously.
The pipes MUST be completely drainable. If the
HOT water faucets are located at a point higher than the water heater, place a drain valve at the lowest point.
48
5
Close the shut-off valve and remove, clean, and replace the water filter.
It is recommended to use unions and flexible copper connections at the COLD and HOT water lines. They allow the water heater to be disconnected easily for servicing.
Use the following guidelines when connecting the
HOT WATER OUTLET:
Connections between the water heater and point(s) of use should be as short as possible.
Local codes shall govern the piping used for water connections.
To conserve energy and to prevent freezing, insulate both COLD and HOT water supply lines.
DO NOT insulate drain line or pressure-relief valve.
Alternate Water Piping Arrangement With Preferred Valve Kit
Service valve kits can attach to all tankless water heater systems. All kits include two full-port isolation valves to be used in the COLD and HOT water lines. When installed, these valves allow one person full diagnostic testing and ease of flushing the system. Contact your distributor or place of purchase for availability and installation information.
Pressure
Relief Valve
Hot Water
Service Valve
Water
Outlet
Cold Water
Service Valve
Water
Inlet
INSTALLATION INSTRUCTIONS
Relief Valve
A new pressure-relief valve, complying with the
Standard for Relief Valves and Automatic Gas
Shut-Off Devices for Hot Water Supply Systems,
ANSI Z21.22/CSA 4.4, must be installed at the
HOT water outlet connection of the water heater during installation. Local codes shall govern the installation of any relief valves.
NOTICE:
• The following drawing illustrates a pressure-only relief valve. If local codes require a combination temperature and pressure-relief valve, you may need to install an extension piece to ensure that the relief valve probe is not directly in the flow path of the water.
• Local codes govern the installation of relief valves. If local codes require that a temperature and pressurerelief valve be installed, the manufacturer recommends a type 40XL Watts temperature and pressure-relief valve or equivalent model be used.
• Manual operation of relief valves should be performed at least once a year.
• If the relief valve on the system discharges periodically, a problem exists. Turn off the water heater, unplug the unit, and call for service.
For safe operation of the water heater, be sure that:
The pressure rating of the relief valve must not exceed 150 psi (1,034 kPa) or the maximum working pressure of the water heater. (See the rating plate on the water heater.)
The BTUH rating of the relief valve must equal or exceed the BTUH input of the water heater. (See the rating plate on the water heater.)
No valve of any type should be installed between the relief valve and the water heater.
Discharge from the relief valve should be piped to a suitable drain. Piping used should be of a type approved for the distribution of hot water.
HOT and COLD water lines should be insulated up to the water heater. See page 50.
The discharge line must be NO SMALLER than the outlet of the relief valve. The drain line must pitch downward to allow for complete drainage of the line and the valve.
The end of the discharge line should not be threaded or concealed and should be protected from freezing. No valve of any type, restriction, or reducer coupling should be installed in the discharge line.
Union
Relief
Valve
Service
Valve
Service
Valve
Union
Hot Water
Supply Outlet
Cold Water Supply
Shut-Off Valve
Cold Water
Supply Inlet
Relief Valve
Discharge Line
One end of the relief valve discharge line connects to the HOT water outlet pipe as shown above. The other end of the pipe should be routed to a suitable drain to eliminate potential water damage.
49
50
INSTALLATION INSTRUCTIONS
Water Supply (cont.)
Hot and Cold Pipe Insulation Installation
!
WARNINGS:
When pipe insulation is not rated for the appropriate weather conditions, install electric heat tracing or equivalent to prevent freezing of the pipes.
For increased energy efficiency, use pipe insulation as shown in the diagram� Insulate the pipes all the way to the top� DO NOT cover any drain or pressure-relief valve(s)�
DO NOT insulate or block drain valve on the hot outlet fitting.
If pipes are allowed to freeze, the water heater and the pipes may malfunction or leak due to freezing water.
NOTICE:
The hot and cold water supply pipes should be insulated to provide additional freeze protection.
Relief
Valve
Water
Outlet
Hot Water
Service Valve
Drain
Drain
Cold Water
Service Valve
Water
Inlet
Gas Supply
Gas Supply System
WARNING:
DO NOT attempt to convert this water heater for use with a different type of gas other than the type shown on the rating plate. Doing so could result in death, personal injury, explosion or fire, product damage, and/or poor operating conditions or performance.
NOTICE:
Gas piping shall be in accordance with local utility company requirements and/or in the absence of local codes, use the latest edition of National Fuel
Gas Code (NFGC), ANSI Z223.1. In Canada, use the latest edition of CAN/CSA B149.1, Natural Gas and
Propane installation code.
Apply a thin coat of pipe compound to all threaded male ends. Compound must be of the type resistant to the action of LP gas.
To ensure proper water heater operation, the gas pipe and gas meter must be sized correctly.
If flexible connectors are used, the minimum inside diameter must be 3/4" or greater and the rated capacity of the connector must be equal to or greater than the BTU capacity of the water heater. See manufacturer information for the gas connector. Lengths over 36 inches are not recommended.
DO NOT use excessive force when tightening the pipe sections. Excessive force can damage the water heater, especially when Teflon pipe compound is used.
Manual Gas
Shut-Off Valve
Manual Gas
Supply Line
Shut-Off Valve
Union
Sediment Trap
Cap
INSTALLATION INSTRUCTIONS
Gas Supply (cont.)
Gas Piping
Pipe-Sizing Procedure
The gas supply system must be properly sized to ensure the proper operation of this tankless water heater as well as all the gas appliances on the system. Failure to ensure the gas system,
(meter, regulators, and piping) are properly sized could result in improper operation of this or other gas appliances. Insufficient gas pressure/supply can cause pilot outages, lockouts, or operating conditions that could lead to an appliance failure, improper combustion, carbon monoxide, sooting, or fire. Gas line sizing is based on gas type, the pressure drop in the system, the gas pressure supplied, and the gas line type. For gas pipe sizing in the United States, refer to the National Fuel Gas
Code, (NFPA 54, ANSI Z223.1). For Canadian gas pipe sizing, refer to the Natural Gas and Propane
Installation Code CAN/CSA B149.1.
These simplified instructions only address low pressure gas systems using Schedule 40 Metallic
Pipe (Black Iron). For hybrid gas systems, high pressure main lines with regulators at the appliances, gas systems piped with corrugated stainless steel tubing (CSST), or Propane gas systems.
Determining the required regulator and gas meter size.
Find the BTU capacity of each appliance on the system. This information is located on a rating label attached to the appliance. Total the BTU of all the appliances together and divide that by the heating value of the fuel (for natural gas the average is
1,024 or 2,546 for propane). This will give you the total cubic feet per hour of gas required for the system.
At your gas meter/regulator there will be a rating plate that gives the cubic feet per hour capacity of that equipment. If the total gas required for the system is greater than the rating of the meter/ regulator then the local gas company will need to be contacted in order to upgrade the meter/ regulator for the system.
Cubic Feet
Per Hour (CFH) =
Gas Input of
Water Heater (BTU/HR)
Heating Value of Gas (BTU/FT 3 )
Determining the required pipe size.
The gas system is designed to operate at a certain maximum pressure drop. A pressure drop greater than what is permissible can cause operational issues with the gas appliances. The National Fuel
Gas Code (NFPA 54, ANSI Z223.1 2012) allows for three pressure drop levels, a 0.3 inch W.C.,
(see table 2); a 0.5 inch W.C., (see table 3) and a 3.0 inch W.C., (see table 4) pressure drop for natural gas. Only a 0.5 inch W.C. pressure drop is allowable with Propane (see table 5). For Canadian installations the maximum allowable pressure drop is 0.5 inch W.C., (see table 3).
Measure the inlet gas pressure to the system using a manometer. For Natural Gas, if the inlet pressure is less than 8.0 inches W.C. then use Table 2 or 3 for your gas pipe sizing. Table 4 can only be used if the inlet gas pressure is 8.0 inches W.C. or greater.
Table 4 cannot be used for Canadian installations.
The gas piping system consists of a main trunk line that runs from the meter/regulator and branch lines that run from the trunk line to the individual appliances. A branch may carry gas for more than one appliance.
The trunk line must be sized to carry the entire load of all the gas appliances on the system. As with determining the meter/regulator size, total the
BTU of all the appliances together and divide that by the heating value of the fuel (for natural gas the average is 1,024 or 2,546 for propane). This will give you the total cubic feet per hour of gas required for the trunk line. Measure the total length of the line Refer to Table(s) 2, 3, or 4 and find the number closest to but higher than the total cubic feet per hour requirement calculation. This will tell you the minimum size that the trunk line must be.
Each branch line must be sized to carry the load of the appliance(s) attached to it. If more than one appliance is on a branch total the BTU and as with the trunk line divide that by the heating value of the fuel. Refer to Table(s) 2, 3, or 4 and find the number closest to but higher than the total cubic feet per hour requirement calculation for the branch and appliance(s). This will tell you the minimum size for that branch line and appliance.
51
52
INSTALLATION INSTRUCTIONS
Gas Supply (cont.)
Final Considerations
If this water heater is replacing an existing water heater, it is important to verify the capacity of the gas system.
Check the capacity of the meter/regulator, and verify the pipe lengths and sizes.
An improperly sized gas system will cause operational issues with this water heater. Other appliances on the gas system may be affected as well.
Flexible Gas Connectors may be used however the
BTU capacity of the connector must be checked. Each connector has a capacity label on it, verify that the connector has a BTU capacity greater than that of the water heater. An undersized flexible gas connector will cause operational issues with this water heater.
Half-inch gas lines are permissible provided the gas system meets certain requirements. First, the gas
Table 2 - Pipe-Sizing - Natural Gas
Schedule 40 Metallic Pipe (Black Iron)
Inlet System Pressure: Less than 2 PSI (55 inches W.C.)
Allowable Pressure Drop: 0.3 inches W.C.
Specific Gravity : 0.60
(Capacity in cubic feet per hour)
Length Pipe Size (Inches)
60
70
80
10
20
30
40
50
½
131
90
72
62
55
¾
273
188
151
129
114
1
514
355
284
243
215
1¼
1,060
726
583
499
442
50
46
42
104
95
89
195
179
167
400
368
343
600
552
514
90
100
40
38
83
79
157
148
322
304
482
455
Information in this chart obtained from NFPA 54, ANSI Z223.1 - 2012 Table 6.2(a)
1½
1,580
1,090
873
747
662
30
40
50
60
70
10
20
Table 4 - Pipe-Sizing - Natural Gas
Schedule 40 Metallic Pipe (Black Iron)
Inlet System Pressure: 8.0 inches W.C. or greater, but Less than 2 PSI (55 inches W.C.)
Allowable Pressure Drop: 3.0 inches W.C.
Specific Gravity : 0.60
(Capacity in cubic feet per hour)
Length
½
454
312
¾
949
652
Pipe Size (Inches)
1
1,787
1,228
1¼
3,669
2,522
1½
5,497
3,778
250
214
190
172
158
524
448
387
360
331
986
844
748
678
624
2,025
1,733
1,536
1,392
1,280
3,778
2,597
2,302
2,085
1,919
80
90
147
138
308
289
580
544
1,191
1,118
1,785
1,675
100 131 273 514 1,056 1,582
Information in this chart obtained from NFPA 54, ANSI Z223.1 - 2012 Table 6.2(c) pressure on the system must be 8.0 inch W.C. or greater. Second the capacity of the pipe as outlined in
Table 4 is followed. If the existing pipes are too small it could cause a pressure drop greater than 3.0 inch
W.C. and will cause operational issues with this water heater as well as other gas appliances on the system.
This is an example, in US, refer to current National Fuel
Gas Code, NFPA 54 for correct pipe sizing chart, and in Canada, refer to current Natural Gas and Propane
Installation Code CAN/CSA B149.1.
Table 3 - Pipe-Sizing - Natural Gas
Schedule 40 Metallic Pipe (Black Iron)
Inlet System Pressure: Less than 2 PSI (55 inches W.C.)
Allowable Pressure Drop: 0.5 inches W.C.
Specific Gravity : 0.60
(Capacity in cubic feet per hour)
Length Pipe Size (Inches)
40
50
60
10
20
30
½
172
118
95
81
72
65
¾
360
247
199
170
151
137
1
678
466
374
320
284
257
1¼
1390
957
768
657
583
528
70
80
90
100
60
56
52
50
126
117
110
104
237
220
207
195
486
452
424
400
728
677
635
600
Information in this chart obtained from NFPA 54, ANSI Z223.1 - 2012 Table 6.2(b)
1½
2090
1430
1150
985
873
791
10
20
30
40
50
60
80
100
Table 5 - Pipe-Sizing - Undiluted Propane
Schedule 40 Metallic Pipe (Black Iron)
Inlet System Pressure: 11 inches W.C.
Allowable Pressure Drop: 0.5 inches W.C.
Specific Gravity : 1.5
(Capacity in cubic feet per hour)
Length Pipe Size (Inches)
½
291
200
160
137
122
110
101
94
¾
608
418
336
287
255
231
212
197
1
1150
787
632
541
480
434
400
372
1¼
2350
1620
1300
1110
985
892
821
763
1½
3520
2420
1940
1660
1480
1340
1230
1140
125
150
89
84
185
175
349
330
716
677
1070
1010
Information in this chart obtained from NFPA 54, ANSI Z223.1 - 2012 Table 6.3(d)
INSTALLATION INSTRUCTIONS
Gas Supply Installation
1
Install the manual gas appliance shut-off valve to the gas connection at the water heater� The shut-off is supplied with the water heater�
4
Using the proper-size piping, fittings, and components, build the gas supply line to the water heater�
NOTICE:
The gas supply line should be a minimum of 3/4in. (1.9-cm) black steel pipe or other approved gas piping material.
2
Install a ground joint union or ANSI design-certified semirigid or flexible gas appliance connector to the open end of the manual gas appliance shut-off valve� The (NFGC)
ANSI Z223�1 and CAN/CSA B149�1 codes mandate the use of manual gas shut-off valves�
5
Install a sediment trap at the lowest portion of the gas line�
The inlet gas pressure to the water heater must NOT exceed 10�5 in� w�c� (2�6 kPa) for natural gas and 13 in� w�c� (3�2 kPa) for LP gas� For purposes of input adjustment, the minimum inlet gas pressure (with main burner on) is shown on the water heater rating plate� If high or low gas pressures are present, contact your gas supplier for correction�
3
Install a manual gas supply line shut-off valve to the end of the gas supply line�
53
54
INSTALLATION INSTRUCTIONS
Gas Supply (cont.)
Leak Testing
!
WARNING:
Never use an open flame to test for gas leaks, because death, personal injury, and/or property damage can result.
The water heater and its gas connections MUST be leak-tested at normal operating pressures before the unit is placed in operation. These tests should also include all factory connections.
Turn on the gas shut-off valve(s) to the water heater.
Use a soapy water solution to test for leaks at all the connections and fittings. If bubbles are seen, it indicates a gas leak that must be corrected.
Contact a qualified service technician.
Pressure Testing the Gas Supply System
!
CAUTION:
If inlet gas pressure is out of allowable range [4.0” w.c. (1.0kPa) – 10.5” w.c. (2.6kPa)] for Natural Gas, or [8.0” w.c. (2.0kPa) – 13.0” w.c. (3.2kPa)] for LP gas, a gas pressure regulator must be installed to maintain the allowable inlet gas pressure.
The water heater and its manual gas shut-off valve must be disconnected from the gas supply piping system whenever the pressure testing will exceed
1/2 psi (14 in. w.c. [3.5 kPa]).
The water heater must be isolated from the gas piping system whenever the pressure testing will be less than and/or up to 1/2 psi (14 in. w.c. [3.5 kPa]).
Closing the manual gas shut-off valve will isolate the water heater from the gas piping system.
INSTALLATION INSTRUCTIONS
High-Altitude Installation
!
WARNING:
DO NOT install this water heater at elevations above
2000 ft. (610 m) without the proper adjustments.
Failure to install a water heater suitable for the altitude at the location it is intended to serve can result in improper operation of the appliance resulting in property damage and/or producing carbon monoxide gas, which could result in personal injury or death.
NOTICE :
For installations above 2000 ft. (610 m) elevation, contact a qualified service technician to make the proper altitude adjustments. You can also contact your local gas supplier, place of purchase, or call the Rheem Customer Service phone number listed on page 26 in the "Call for Assistance" section.
See pages 70 and 71 for additional information.
Electrical Wiring
!
DANGER:
Shock Hazard – Before servicing the water heater, turn off the electrical power to the water heater at the main disconnect or circuit breaker. Failure to do so will result in death or serious personal injury.
!
WARNING:
Field wiring connections and electrical grounding must comply with local codes or, in the absence of local codes, with the latest edition of the National
Electrical Code, ANSI/NFPA 70, in the U.S., or
Canadian Electrical Code, CAN/CSA C22.1, Part 1, in
Canada.
!
CAUTION:
Labeling all wires prior to disconnection is recommended. Wiring errors can cause personal injury, product damage, and/or dangerous operating conditions. Verify correct operation after servicing.
NOTICE:
• DO NOT connect power until venting installation is complete (see Venting Installation pages 34–45).
• Wait ninety (90) seconds after power is connected for the first time to initiate operation of the water heater.
• Power consumption is up to 100 Watts during normal operation, 3-5 Watts during standby, waiting to run, and up to 200 Watts during the freeze protection operation.
Power Cord
The electric power supply requirement for this water heater is 120 VAC/60 Hz, 2 Amps.
A dedicated circuit is recommended for the water heater. DO NOT connect to a GFCI or AFCI circuit.
Multiple units may be connected to a single circuit up to the circuit rating.
DO NOT use 3-prong to 2-prong adapters. DO
NOT use power strips or multiple outlet adapters.
All direct-vent gas models come with a threeprong power cord. Only use this power cord and a matching grounded electrical outlet.
All outdoor gas models do not come with a power cord. Only hard-wire to an appropriate power outlet with a ground terminal.
Keep any excess length of the power supply cord on the outside of the water heater.
If local codes require hard-wiring, see instructions for “Hard-Wiring the Electrical Connections” below.
Hard-Wiring the Electrical
Connections
Wiring should be performed by a qualified electrician in accordance with local codes.
The water heater requires a properly grounded 120
VAC/60 Hz power supply. Multiple water heaters may be connected to a single circuit up to that circuit’s rating.
DO NOT connect grounding wire to water pipes, gas pipes, telephone cables, lighting conductor circuits, or to any other grounding circuits that require a GFCI or AFCI (arc fault circuit interrupter).
An ON/OFF switch must be provided and installed for the incoming 120 VAC power supply.
Wire the water heater exactly as shown in the wiring diagram. This wiring diagram can also be found inside the water heater cover panel.
The green screw is provided in the enclosure for a grounding connection.
Connect the live wire to the black wire and neutral wire to the white neutral wire.
55
56
INSTALLATION INSTRUCTIONS
Electrical Wiring (cont.)
Wiring Diagram
INSTALLATION INSTRUCTIONS
Remote Control Selection and Location
WARNING:
Field wiring connections and electrical grounding must comply with local codes or, in the absence of local codes, with the latest edition of the National
Electrical Code, ANSI/NFPA 70, in the U.S., or
Canadian Electrical Code, CAN/CSA C22.1, Part 1, in
Canada.
NOTICE:
The provided remote control will allow maximum temperature settings of 120°F (49°C). Temperatures up to 140°F (60°C) for residential applications and up to 185°F (85°C) for commercial applications* can be achieved with the MAIN (UMC-117) remote control.
Only qualified service personnel should perform this adjustment.
• An optional cable (EZ Link Cable TM ) can be purchased separately to manifold two water heaters together�
• DO NOT attempt to disassemble sealed and calibrated for accurate water heater control and operation�
One remote control is provided with the water heater� Additional remote controls may be purchased separately� The available remote controls are listed in the following chart� Up to three remote controls can be used with the water heater� No other manufacturer’s controls are suitable for use with this water heater�
Review the following considerations before determining the location of the remote control(s):
• DO NOT install any remote control with water�
• Avoid installing the remote control in the following areas and/or conditions:
– area exposed to heat�
– area exposed to steam�
– area exposed to oil�
– area exposed to direct sunlight�
– areas near stored or used flammable products�
• Place remote control out of children’s reach�
• The remote control should be installed in a convenient location (e�g�, kitchen, laundry room, utility room, or directly next to the water heater)�
• The maximum distance between the water heater and the remote control installation location is limited to 195 ft� (59 m) of wire�
Remote Control
Model Number
UMC-117
USC1-117
USC2-117
Remote Control
Description
MAIN
BATH 1
BATH 2
Temperature
Set Point Range
100°F–120°F (38°C–49°C)
85°F (29°C)
125°F–140°F (52°C–60°C)
85°F (29°C)
125°F–185°F (52°C–85°C)
100°F–120°F (38°C–49°C)
85°F (29°C)
100°F–120°F (38°C–49°C)
85°F (29°C)
Availability
Factory Default
Qualified Technician
Adjustment for Residential Products
Qualified Technician
Adjustment for Commercial Products*
Optional (Sold Separately)
Qualified Technician Adjustment
Optional (Sold Separately)
Qualified Technician Adjustment
MIC-6 or MIC-185**
Manifold System
Manifold System Optional (Sold Separately)
*A commercial conversion kit can be purchased to achieve temperatures up to 185°F (85°C)�
** When a manifold system is installed, the main remote control connected to the manifold controller (MIC-6 or MIC-185) has priority over the remote controls connected to the water heater�
57
58
INSTALLATION INSTRUCTIONS
Electrical Wiring (cont.)
Remote Control Installation
WARNING:
Field wiring connections and electrical grounding must comply with local codes or, in the absence of local codes, with the latest edition of the National
Electrical Code, ANSI/NFPA 70, in the U.S., or
Canadian Electrical Code, CAN/CSA C22.1, Part 1, in
Canada.
NOTICE:
Extension cable can be any 18 AWG wire similar to a thermostat wire and need not be polaritysensitive.
It is not recommended to have wiring exposed.
DO NOT apply sealant to remote control cable.
DO NOT use network cable, telephone wire, or any twisted-pair cable.
Connecting the MAIN (UMC-117) Remote Control to a
Wall:
4
Install the base plate to the wall using suitable screws and wall anchors.
NOTICE:
The tabs on the base plate should always point out.
5
Connect the remote control to the remote control cable.
1
Drill a 1- to 1 1/2-in. (2.5/3.8-cm) hole at the proposed control location. Install the remote control cable between the location of the remote control and the water heater.
2
Remove the remote control from the base plate.
6
Position the remote control on the base plate.
NOTICE:
The tabs on the base plate should line up with the slots on the back of the control panel.
Secure the control panel to the base plate with one screw into the bottom tab.
NOTICE:
DO NOT attempt to connect the remote control or control wire to the water heater while the water heater has power applied to it. Damage to the water heater will occur. DO NOT cut or strip the wiring while it is connected to the water heater or while the water heater has power applied to it.
3
Feed the remote control cable through the large center hole in the base plate.
INSTALLATION INSTRUCTIONS
Remote Control Installation (cont.)
Connecting the Remote Control to the Water
Heater:
1
Ensure that the power to the water heater has been disconnected.
4
Firmly tighten the terminal screws by hand.
Remote Control
Connection Cover
2
Loosen the one screw located on the remote control connection cover. The connection cover is made of white plastic.
NOTICE:
DO NOT REMOVE FRONT PANEL. Remote control wires are connected on the bottom of the unit.
There are no accessible remote control terminals inside the water heater.
5
Secure the remote control extension cable on the hook located on the side of the remote control connection base.
6
Reinstall the remote control connection cover and secure with the one screw.
3
Connect the remote control extension cables from the remote control to the remote control connection terminals.
NOTICE:
The remote control wire connection terminals are not polarity-sensitive.
7
Switch on the power supply to the water heater.
Check for proper operation of the remote control and the water heater.
59
60
INSTALLATION INSTRUCTIONS
Insulation Blankets
In general, insulation blankets for external use on gas water heaters are not necessary� The purpose of an insulation blanket is to reduce the standby heat loss from the water heater’s storage tank� Since these water heaters do not store water, they eliminate the need for the insulation blanket�
WARNING:
NEVER cover the air inlet, flue outlet, or operating and warning labels attached to the water heater.
Covering these components will cause dangerous operating conditions that can lead to death, personal injury, property damage, and/or product damage.
The manufacturer’s warranty does not cover any damage or defect caused by insulation, insulation attachment, or use of any type of energy-saving or other unapproved devices (unless authorized by the manufacturer)� The use of unauthorized energy-saving devices can result in death, personal injury, and/or property damage� The manufacturer disclaims any responsibility for such loss or injury resulting from the use of such unauthorized devices�
Installation Precautions
Follow all installation instructions covered in this manual.
Check the inlet gas pressure to make sure it is within the range specified on the rating plate.
Make sure there is adequate air for combustion and ventilation as described on pages 38–39 or page 43 in this manual.
Maintain proper clearances to combustibles and non combustibles as specified on the rating plate.
Make sure the venting system complies with local codes, National Fuel Gas Codes (ANSI Z223.1/
NFPA 54) or CAN/CSA B149.1, and the guidelines found on pages 34 through 45 in this manual.
Contact the local gas company to make sure the gas meter and gas piping are adequately sized.
Use Teflon tape on all male water line connections and fittings.
DO NOT block or restrict any air intake openings.
DO NOT remove the front cover unless absolutely necessary. This should only be done by a qualified service technician.
DO NOT install this product where standing water may occur.
DO NOT use pipe dope on water line connections and fittings.
Installation Checklist
A. Water Heater Location
Indoor water heaters must be installed indoors�
Outdoor water heaters must be installed outdoors�
Close to area of ventilation termination
(indoor models)�
Protected from freezing temperatures�
Proper clearance from combustible material observed�
Sufficient fresh air supply for proper operation of water heater�
Air supply free of corrosive elements and flammable vapors�
Provisions made to protect area from water damage�
Sufficient room to service heater�
Combustible materials, such as clothing, cleaning materials, and rags, clear of the heater and vent piping�
Water heater is properly attached to the wall�
B. Coaxial Vent (Indoor Models)
Vent pipe material is Category III and is manufacturer-approved�
Horizontal vent runs have 1/4 in� per foot of
DOWNWARD slope towards the vent terminal�
Vertical venting is installed as described on pages
44 and 45�
Connector(s) securely fastened together with hightemperature silicone (500°F [260°C]) and airtight�
All coaxial vent runs are properly installed�
Vent terminal is properly installed�
Maximum vent length is observed�
INSTALLATION INSTRUCTIONS
C. Water Supply/Relief Valve
Water supply has sufficient pressure�
Air has been purged from the water heater and the piping�
Water connections tight and free from leaks�
Water filter is clean and in place�
All piping has been assembled as described on pages 47 and 48�
Water pipes are insulated and protected from freezing, if necessary�
Pressure-relief valve properly installed with discharge line running to open drain�
Discharge line protected from freezing, if necessary�
D. Gas Supply
Gas type matches listing on rating plate�
Gas supply pressure is sufficient for the water heater�
Gas line equipped with shut-off valve, union, and sediment trap as described on page 53�
Approved pipe-joint compound has been used on all gas pipe connections�
All connections and fittings have been checked for leaks with a soapy water solution�
Gas company inspected installation (if required)�
E. Electrical Wiring
Supply cord and/or wiring meets all local codes,
National Electrical Code, ANSI/NFPA 70, in the U�S�, or Canadian Electrical Code, CAN/CSA C22�1, Part
1, in Canada�
Voltage matches listing on rating plate�
Water heater is properly grounded�
F. Condensate
Drain hose is attached to the condensate collector, and condensate is drained as described on page 37�
61
INSTALLATION INSTRUCTIONS
Piping for Space Heaters
Local codes or plumbing authority requirements may vary from the instructions or diagrams provided in this manual and take precedence over these instructions�
Combination Potable and Space
Heating Application
DANGERS:
When this system requires water for space heating at elevated temperatures (above 125°F [52°C]), a mixing or tempering valve must be installed in the hot water supply line to the house in order to reduce the scald hazard potential.
• Any piping or components used in the installation of this water heater in a combination potable and space heating application must be suitable for use with drinking water.
Typical Combination Illustration
• If this water heater is installed in an application intended to supply domestic hot water needs and hot water for space heating purposes, do not connect the heater to an existing heating unit or components of a heating system that have previously been used with a nondrinking water system. Toxic chemicals such as those used for boiler treatment may be present and will contaminate the drinking water supply causing possible health risks. Never introduce toxic chemicals, such as those used for boiler treatment, into this system.
• This water heater is not approved as the dedicated space heating unit. This water heater must be used for combination applications with air handler only and not for indoor heating applications.
62
Air Handler
INSTALLATION INSTRUCTIONS
Recirculation Control
Local codes or plumbing authority requirements may vary from the instructions or diagrams provided in this manual and take precedence over these instructions�
Your tankless water heater has the ability to control an external recirculation pump� Two modes are available,
Energy Saver and Performance, which recirculate the water in the plumbing system to provide hot water more quickly when a faucet is opened� Rheem offers a fully packaged recirculation pump kit� See the Parts and
Accessories catalog for more information�
NOTICE:
Recirculation control is for residential application only. Recirculation control cannot be used with an air handler or with multiple water heater installations. The maximum temperature setting is
140°F (60°C) in recirculation control.
Pump Requirements
Voltage: 120V, 60Hz
In-rush current: Less than 2�5 amps
Amperage: less than 2�0 amps
WARNING:
A control board can be damaged if amperage exceeds 2.0 amps.
Pump Size
The pump should be sized for about 2�5 gpm at the pressure drop through the tankless water heater and the supply and return plumbing in the recirculation loop�
Contact service department listed on page 26 of this use and care manual if you need more information�
Typical Recirculating Pump Installation
Remote
Control
Tankless
Water Heater
Single Unit
3
Hot Water to Fixtures
3/4”
Hot Water
Loop
Dedicated
Return Line
3/4”
Wire to Connect to Pump
Circulation
Pump
Cold water to Tankless
Expansion
Tank
Cold Water
Supply
63
64
INSTALLATION INSTRUCTIONS
Recirculation Control (cont.)
Installation
1
Disconnect all electric power to the water heater.
Control
Board
Blue
connector
Add
4 Amp
Fuse
BK
PUMP
W
Cut blue connector and splice wires.
5
To connect to the pump, cut the blue connector, splice the wires, and add a 4 amp fuse to the hot wire of the pump.
2
Remove the front cover panel on the water heater.
Install the recirculation pump on the return line according to the pump manufacturer installation instructions. Install a check valve in the return line as shown in typical recirculation pump installation if one is not integrated into the pump. See the bottom of page 63 for Typical Recirculation Pump
Installation.
* Check valve is included in Rheem recirculation pump kit.
3
Ground
6
Connect the ground wire from the pump to a screw at the base of the water heater cabinet.
NOTICE:
Follow any applicable electrical code and the pump manufacture installation instruction referring to the
Pump Electrical Connection Diagram in Step 5 of these instructions.
Control
Board
Blue
connector
BK
4
W
The wire harness for the recirculation pump is bundled with the wire harness from the control board. Find a blue connector with a black and a white wire.
Dip Switches
Control Board
7
Find DIP Switch 2 in the top-right portion of the control board. The switch labeled “DIP 2” is the bottom switch.
INSTALLATION INSTRUCTIONS
As set from factory
8
MIN MAX ADJ
The factory setting for this switch should all be in the OFF position (DOWN).
9
Change the first switch on “DIP 2” to the ON position (UP). Performance mode is selected.
10
To select Energy Saver mode, change the fourth switch on “DIP 1” to the ON position (UP).
11
Replace the front cover panel.
12
Turn on all electric power to the water heater.
Turn On the remote control. The pump and water heater will turn on to raise recirculation loop temperature.
Recirculation Operation
The water heater is turned ON when the recirculation pump starts operation. The water heater produces hot water at the setting temperature. When the return water temperature reaches approximately 15°F below the setting temperature, the water heater and the pump will turn OFF. The cycle will restart at the approximate time interval in the table below based on the temperature thermistor readings.
Energy Saver Mode
The Energy Saver mode operates as follows:
• Less energy consumption due to fewer pump cycles
• Pump cycles ON every 30 to 69 minutes
Performance Mode
The Performance mode operates as follows:
• Higher energy consumption due to more pump cycles
• Pump cycles ON every 15 to 35 minutes
Setting Temp
106
104
102
100
114
112
110
108
125
120
118
116
[°F]
140
135
130
Typical Pump ON Intervals [Min]
26
28
31
35
19
20
22
24
15
16
17
18
Performance
15
15
15
51
56
62
69
38
40
44
47
30
31
33
35
Energy Saver
30
30
30
Actual pump ON intervals may vary based on the setting temperature, insulation, and heat loss in the system.
65
INSTALLATION INSTRUCTIONS
Activating the Water Heater
WARNING:
Before operating this water heater, be sure to read and follow the instructions on the following label, all labels on the water heater, and the “Important
Safety Information” section in this manual. Failure to do so can result in unsafe operating conditions that can result in death, personal injury, property damage, and/or product damage.
FOR YOUR SAFETY READ BEFORE OPERATING
WARNING
: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
66
OPERATING INSTRUCTIONS
1.STOP! Read the safety information above on this label.
2.Turn off all electric power to the appliance.
GAS SHUTOFF
3.Do not attempt to light the burner by hand.
VALVE
4.Turn the Gas Shutoff Valve located on the outside of the unit
OPEN CLOSE
clockwise to the "OFF" position.
5.Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow "B" in
the safety information above on this label. If you don't smell gas, go to the next step.
6.Turn the Gas Shutoff Valve located on the outside of the unit counterclockwise to
the "ON" position.
7.Turn on all electric power to the appliance.
8.If the appliance will not operate, follow the instructions "To Turn Off Gas To Appliance"
and call your service technician or gas supplier.
TO TURN OFF GAS TO APPLIANCE
1.Turn off all electric power to the appliance if service is to be performed.
2.Turn the Gas Shutoff Valve located on the outside of the unit clockwise to the "OFF" position.
INSTALLATION INSTRUCTIONS
Operating Instructions
Read, understand, and follow the safety information listed on the operating label on page 63 and in the
“Important Safety Information” section on pages
2-8 in this manual.
1
Disconnect all electric power to the water heater.
2
Turn the gas shut-off valve clockwise to the OFF position. This valve is located on the outside of the water heater. Wait 5 minutes to clear any gas. If you don’t smell gas, proceed to Step 3.
NOTICE:
If you smell gas, STOP and follow the safety instructions listed under B on the operating label or on the front cover of this manual.
4
Turn on all electric power to the water heater. The water heater burner will automatically light when there is a demand for hot water.
WARNING:
DO NOT attempt to light the burner by hand.
Lighting the burner by hand is an unsafe operating condition that can result in death, personal injury, property damage, and/or product damage.
If the water heater burner will not light, turn off the water heater as described below and call your service technician or gas supplier.
Shutting Off the Water Heater
1
Disconnect all electric power to the water heater.
3
Turn the gas shut-off valve counterclockwise to the ON position�
2
Turn the gas shut-off valve clockwise to the OFF position.
67
INSTALLATION INSTRUCTIONS
The contents on pages 68 through 75 should only be performed by qualified service personnel.
Setting the Water Temperature
WARNING:
Improper adjustment, alteration, service, or maintenance can result in death, personal injury, property damage, and/or product damage.
In-Use
Indicator
(Lit during operation)
Maximum Temperature Adjustment by the Main Remote Control (UMC–117)
DANGER:
Water temperatures above 125°F (52°C) will result in death and/or severe burns from scalding.
WARNING:
Refer to chart below and the scald potential warnings on page 4 on this manual before making an adjustment. Changing this setting is done at your own risk.
Time/Temperature Relationship in Scalds
LED Display
(Displays water temperature and error codes)
1
Turn on the remote control.
Priority
Indicator
Temperature
Adjustment
Buttons
ON/OFF
Button and
Indicator
To change the temperature settings up to 140°F
(60°C):
Water
Temperature
Time to Produce a Serious Burn Turn off the gas and water to the water heater by
120°F (49°C)
125°F (52°C)
130°F (54°C)
135°F (57°C)
140°F (60°C)
145°F (63°C)
150°F (66°C)
155°F (68°C)
Table courtesy of Shriners Burn Institute
More than 5 minutes
1 1/2 to 2 minutes
About 30 seconds
About 10 seconds
Less than 5 seconds
Less than 3 seconds
About 1 1/2 seconds
About 1 second
Residential water heater temperatures can be adjusted up to 140°F (60°C). DO NOT perform the following adjustment if a setting of up to 140°F
(60°C) is not required.
2 closing the shut-off valves.
Press the UP adjustment button repeatedly until
3
120°F (49°C) shows in the LED display. Hold the
UP button until “140” on the display starts to blink.
NOTICE:
LED display only shows °F.
68
INSTALLATION INSTRUCTIONS
4
While “140” is blinking, press the UP and DOWN adjustment buttons at the same time. “140” will appear without blinking.
3
Press the DOWN adjustment button repeatedly until 100°F (38°C) or 85°F (29°C) shows in the
LED display. Hold the DOWN button until the number on the display starts to blink.
5
Press the UP or DOWN adjustment button to set the desired temperature.
4
While the number is blinking, press the UP and
DOWN adjustment buttons at the same time. The number will stop blinking.
6
Turn on the gas and water to the water heater by opening the shut-off valves.
To limit maximum water temperature setting to 120°F (49°C):
5
Press the UP or DOWN adjustment button to set the desired temperature.
1
Turn on the remote control.
6
Turn on the gas and water to the water heater by opening the shut-off valves.
2
Turn off the gas and water to the water heater by closing the shut-off valves.
69
INSTALLATION INSTRUCTIONS
Setting the Water Temperature (cont.)
Minimum Temperature Adjustment by the Main Remote Control (UMC–117,
USC1–117, and USC2–117)
Residential water heater temperatures can be adjusted down to 85°F (29°C), when required.
To change the temperature settings down to
85°F (29°C):
3
Press the DOWN adjustment button repeatedly until 100°F (38°C) shows in the LED display.
NOTICE:
LED display only shows °F.
1
Turn on the remote control.
4
Press the DOWN adjustment button 3 times within
5 seconds. The display will show “85.”
2
Turn off the gas and water to the water heater by closing the shut-off valves.
5
Turn on the gas and water to the water heater by opening the shut-off valves.
NOTICE:
The maximum flow rate at 85°F (29°C) is 1.3 gpm
(5.0 L/m).
High-Altitude DIP Switch Adjustments
Verify the altitude that the water heater is installed.
When the water heater is installed above 2000 ft.
(610 m), the settings on the DIP switch located on the control board must be changed. If these settings are not changed, the water heater will not function properly.
NOTICE:
If the water heater is installed under 2000 ft. (610 m) altitude, no adjustments are necessary.
1
Turn off the gas and water to the water heater by closing the shut-off valves.
70
INSTALLATION INSTRUCTIONS
High-Altitude DIP Switch Adjustments (cont.)
5
If altitude is above 2000 ft. (610 m) and below
5,400 ft. (1650 m), change the third switch on “DIP
2” to the ON position (UP).
2
Remove the front cover panel on the water heater.
Dip Switches
Control Board
3
Find DIP Switch 2 located in the top-right portion of the control board. The switch labeled “DIP 2” is the bottom switch.
6
If altitude is above 5,400 ft. (1650 m) and below
8,500 ft. (2590 m), change the fourth switch to the
ON position (UP).
NOTICE:
DO NOT alter any other DIP switch settings. The manifold pressure will be reduced accordingly.
Some models are not available at higher than
5400 ft (1650m). Please contact technical service listed on page 26 of this use and care manual if you have any questions of high altitude DIP switch adjustments.
As set from factory
4
MIN MAX ADJ
The factory settings for this switch should all be in the OFF position (DOWN).
7
Replace the front cover panel.
8
Turn on the gas and water to the water heater by opening the shut-off valves.
71
72
INSTALLATION INSTRUCTIONS
Water Saving Control
Water saving control is optional and is inactive as default. To activate this control, appropriate procedures must be followed.
Water saving control can reduce waste water at initiation of hot water demand by reducing flow until set temperature is reached of outlet hot water. It is recommended to turn ON this control if the water heater is installed in a drought area or anywhere water conservation is needed.
Follow the steps below to turn ON the water saving control.
4
Change the third switch on “DIP 1” to the ON position (UP).
1
Turn off the gas and water to the water heater by closing the shut-off valves.
5
Replace the front cover panel.
2
Remove the front cover panel on the water heater.
6
Turn on the gas and water to the water heater by opening the shut off valves.
Follow the below steps to turn OFF the water saving control.
Dip Switches
Control Board
3
Find DIP Switch 1 located in the top-right portion at the control board. The switch labeled “DIP 1” is the top switch.
1
Turn off the gas and water to the water heater by closing the shut-off valves.
INSTALLATION INSTRUCTIONS
2
Remove the front cover panel on the water heater.
Dip Switches
Control Board
3
Find DIP Switch 1 located in the top-right portion at the control board. The switch labeled “DIP 1” is the top switch.
4
Change the third switch on “DIP 1” to the OFF position (DOWN).
5
Turn on the gas and water to the water heater by opening the shut-off valves.
73
INSTALLATION INSTRUCTIONS
Maintenance Notice
Maintenance notice is an optional control and is inactive as default. Maintenance notice reminds users of water heater maintenance activities such as flushing the heat exchanger or replacing the water treatment filter (if applicable) in order to maximize the life of your tankless water heater.
Contact technical service department listed on page 26 of this use and care manual if you are not familiar with these maintenance activities.
As set from factory
5 MIN MAX ADJ
The factory settings for this switch should all be in the OFF position (DOWN).
1
Turn off the remote control.
2
Turn off the gas and water to the water heater by closing the shut-off valves.
6
MIN MAX ADJ
Change the third and fourth switches on “DIP 2” to the ON position (UP).
3
Remove the front cover panel on the water heater.
7
MIN MAX ADJ
Push and hold “Max” button until “ON” is shown on the display of the remote control.
74
Dip Switches
Control Board
4
Find DIP switch 2 located in the top-right portion of the control board. The switch labeled “DIP 2” is the bottom switch.
8
Change the third and fourth switches on “DIP 2” to the OFF position (OFF).
INSTALLATION INSTRUCTIONS
11
Turn on the gas and water to the water heater by opening the shut off valves.
9
Replace the front cover panel.
10
Turn on the remote control.
Error Code 88 Clearing
When a tankless water heater has a certain number of hours of combustion, error code
“88” is shown on the remote control. It is highly recommended to perform water heater maintenance activities such as flushing the heat exchanger and/or replacing the water treatment filter (if applicable). After these maintenance activities are made, follow the steps below in order to clear error code “88”.
3
Press the DOWN adjustment button repeatedly until the lowest setting temperature shows in the
LED display.
1
Turn on the remote control.
4
Press and hold the DOWN and UP adjustment button for 5 to 10 seconds.
2
Turn off the gas and water to the water heater by closing the shut-off valves.
5
Turn on the gas and water to the water heater by opening the shut off valves.
If error code "88" is still shown, repeat steps 1 through 5 above.
75
PARTS REPLACEMENT
Parts Ordering
WARNING:
For your safety, DO NOT attempt to disassemble, repair, or replace any portion of this unit. Refer all repairs, service, and/or adjustments to qualified service personnel.
Address all parts orders to the distributor or store where the water heater was purchased. All parts orders should include:
Direct-Vent Gas Components
1. The model and serial number of the water heater from the rating plate.
2. Specify the gas type (natural or LP) as marked on the rating plate.
3. Parts description (as shown below) and number of parts desired.
15
76
3
Ref #
3
4
5
1
2
6
7
8
13
11
14 9 10
7
5
8
Description
Control Board
Gas Valve Assembly
Burner Assembly
Igniter Coil
Blower Motor
Burner Manifold
Gas Inlet Connector 3/4"
Water Control Valve
Ref #
8a
9
10
11
13
14
15
8a
1
6
4
2
Description
Water Bypass Valve
Water Inlet Connector 3/4"
Inlet Water Filter
Hot Outlet Connector 3/4"
Front Cover
Remote Control Terminal Block
Concentric Vent Connector Assembly
PARTS REPLACEMENT
Outdoor Gas Components
3
Ref #
11
13
14
8
8a
9
10
3
4
1
2
5
6
7
13
11
14 9 10
7
5
8
Description
Control Board
Gas Valve Assembly
Burner Assembly
Igniter Coil
Blower Motor
Burner Manifold
Gas Inlet Connector 3/4"
Water Control Valve
Water Bypass Valve
Water Inlet Connector 3/4"
Inlet Water Filter
Hot Water Outlet Connector 3/4"
Front Cover
Remote Control Terminal Block
8a
1
2
6
4
77
78
NOTES
LIMITED WARRANTY
For the RHEEM®, RUUD®, Richmond®, Paloma®, and Sure Comfort® Residential Tankless Gas Water Heaters.
GENERAL
This Limited Warranty is only available to the original owner of the water heater at the original installation location. This Limited Warranty is not transferable.
Rheem Sales Company, Inc. (Rheem) warrants this tankless gas water heater, and its component parts, to be free from defects in materials and manufacture, under normal use and service, for the Applicable Warranty Period specified below. At its option, Rheem will repair or replace the defective water heater, or defective component part(s), in accordance with the terms of this Limited Warranty, if it fails in normal use and service during the Applicable Warranty Period. The replacement water heater must be manufactured by Rheem under one of the covered brand names. The replacement component part(s) must be Rheem authorized component part(s). The replacement unit will be warranted only for the unexpired portion of the original unit’s Applicable Warranty Period.
Rheem strongly recommends that this tankless water heater be installed by a contractor that is licensed, state qualified and trained on
Rheem's tankless products because improper installation may invalidate warranty coverage.
EFFECTIVE DATE
The Effective Date of warranty coverage (or the beginning of the Applicable Warranty Periods) is the date of the original installation of the water heater, if properly documented. Otherwise, it is the date of manufacture of the water heater plus ninety (90) days.
APPLICABLE WARRANTY PERIODS: The Applicable Warranty Period depends on the type of installation, as described below:
Residential: a Single Family Dwelling
Twelve (12) years from the Effective Date for the heat exchanger, five (5) years from the Effective Date for the component parts, and one (1) year from the Effective Date for certain labor as described under the heading, LABOR, SHIPPING AND PROCESSING COST.
Residential: a Single Family Dwelling used with Hydronic Force Air Heating
Ten (10) years from the Effective Date for the heat exchanger, five (5) years from the Effective Date for the component parts, and one (1) year from the Effective Date for certain labor as described under the heading, LABOR, SHIPPING AND PROCESSING COST. Provided that a
Rheem manufactured/ Rheem approved potable water hydronic air handler is installed with the system.
Residential: a Single Family Dwelling with recirculation, controlled loop
Twelve (12) years from the Effective Date for the heat exchanger, five (5) years from the Effective Date for the component parts, and one (1) year from the Effective Date for certain labor as described under the heading, LABOR, SHIPPING AND PROCESSING COST. Provided that the recirculation system is an on demand type system or the pump is controlled with a temperature sensor (aquastat) and timer.
Residential: a Single Family Dwelling with recirculation, uncontrolled loop
Three (3) years from the Effective Date for the heat exchanger, three (3) years from the Effective Date for the component parts, and one (1) year from the Effective Date for certain labor as described under the heading, LABOR, SHIPPING AND PROCESSING COST, if the water heater is installed in a system in which the water is re-circulated using a continuously operating pump.
Commercial: any installation that is not a single family dwelling
Five (5) years from the Effective Date for the heat exchanger, five (5) years from the Effective Date for the component parts, and one (1) year from the Effective Date for certain labor as described under the heading, LABOR, SHIPPING AND PROCESSING COST.
Commercial: with recirculation, controlled loop
Five (5) years from the Effective Date for the heat exchanger, five (5) years from the Effective Date for the component parts, and one (1) year from the Effective Date for certain labor as described under the heading, LABOR, SHIPPING AND PROCESSING COST. Provided that the recirculation system is an on demand type system or the pump is controlled with a temperature sensor (aquastat) and timer.
Commercial: with recirculation, uncontrolled loop
Three (3) years from the Effective Date for the heat exchanger, three (3) years from the Effective Date for the component parts, and one (1) year from the Effective Date for certain labor as described under the heading, LABOR, SHIPPING AND PROCESSING COST, if the water heater is installed in a system in which the water is re-circulated using a continuously operating pump.
WARRANTY EXCLUSIONS
This Limited Warranty will not cover: a) Damages, malfunctions or failures resulting from: pH
Chart for Recommended Water Quality Levels
(Total Dissolved Solids) TDS Free Carbon Dioxide (CO
2
) Total Hardness Aluminum Chlorides
Up to 500 mg/L Up to 15 mg/L
Copper Iron Manganese Zinc
Up to 200 mg/L 0�05 to 0�2 mg/L Up to 250 mg/L Up to 1�0 mg/L Up to 0�3 mg/L Up to 0�05 mg/L Up to 5 mg/L 6�5–8�5
Cited reference: National Secondary Drinking Water Regulations
1. Installation of the water heater in environments in which water quality levels do not fall within the ranges listed in the table above: b) Operating the water heater in a corrosive or contaminated atmosphere, including without limitation damages, malfunctions or failures caused by lime, mineral build-up, or scale.
c) Service trips to your business to teach you how to install, use, or maintain this water heater or to bring the water heater installation into compliance with local building codes and regulations or manufacturer’s installation requirements.
d) Water heater unit installed for use in: spa or pool heating; a recreational vehicle; a boat or any other watercraft.
e) Water heater unit installed in any circulating system in which the temperature of the incoming water to the water heater is in excess of 140° f.
f) Water heater unit that is installed in any installation supplying radiant heat, such as in floor, baseboard, radiators, snow melt or closed loop systems, or any system using glycol or non-potable water.
g) Damages, malfunctions or failures resulting from failure to install the water heater in accordance with applicable building codes/ordinances or good plumbing and electrical trade practices.
h) Damages, malfunctions or failures resulting from improper installation or failure to operate and maintain the unit in accordance with the manufacturer’s instructions.
i) Performance problems caused by improper sizing of the water heater or the gas supply line, the venting connection, combustion air openings, electric service voltage, wiring, or fusing.
j) Damages, malfunctions or failures caused by improper conversion from natural gas to LP gas or LP gas to natural gas fuel source.
k) Damages, malfunctions or failures caused by operating the water heater with any parts removed or with modified, altered, or unapproved parts installed.
l) Damages, malfunctions or failures caused by abuse, accident, fire, flood, freeze, lightning, acts of God and the like.
m) Heat exchanger failures (leaks) caused by operating the water heater in a corrosive or contaminated atmosphere or damages, malfunctions or failures caused by lime, mineral build-up, or scale.
n) Damages, malfunctions or failures caused by operating the unit at water temperatures exceeding the maximum setting of the operating, or high limit, control.
o) Heat exchanger failures caused by operating the water heater when it is not supplied with potable water, free to circulate at all times.
p) Damages, malfunctions or failures caused by subjecting the heat exchanger to pressures, or firing rates, greater than those shown on the rating label.
q) Damages, malfunctions or failures resulting from the use of any attachment, including any energy saving device, not authorized by Rheem.
r) Units installed outside the fifty states (and the District of Columbia) of the United States of America and Canada.
s) Units removed from the original installation location and reinstalled elsewhere.
t) Units that have had their rating labels altered, tampered with, or removed. A water heater should not be operated if the rating label is removed.
79
80
LABOR, SHIPPING, AND PROCESSING COSTS
For one (1) year after the Effective Date, Rheem will cover reasonable labor costs necessary to repair or replace a tankless water heater or component part that Rheem determines to be defective and covered by this Limited Warranty. The warranty service must be performed by a contractor that is licensed, state qualified, and trained to install and service Rheem's tankless water heaters. This Limited Warranty does not cover any labor expenses for general service, inspection, reinstallation, permits, removal and disposal of the failed water heater or defective component part(s), or updating the installation to meet manufacture or local code requirements. All such expenses are your responsibility.
Rheem will pay the transportation costs for an “in-warranty” replacement water heater, or “in-warranty” replacement component part(s), to a convenient delivery point (selected by Rheem) near the place the original water heater, or original component part(s), is located: such as a local water heater distributor. You must pay any local freight charges, including the cost of returning the failed water heater, or defective component part(s) to a convenient shipping location (selected by Rheem): such as a local Rheem distributor.
Rheem does not authorize, recommend, or receive any benefit from any claims processing or similar fees charged by others to process warranty claims for any water heater or component part(s). Rheem will not reimburse any party for these, or any other, fees not specifically covered in this Limited Warranty document.
HOW TO OBTAIN WARRANTY CLAIM ASSISTANCE
Any claim for warranty assistance must be made promptly. First, determine if your water heater is “in-warranty” (that is, within the Applicable Warranty Period).
You can determine your unit’s warranty status by adding its Applicable Warranty Period to its date of installation. However, if you do not have documentary proof of your water heater’s date of installation, your unit’s warranty status will be based on its date of manufacture as determined from the serial number. Add the Applicable Warranty Period plus ninety (90) days to the date of manufacture to determine whether the water heater is still covered by this Limited Warranty.
You may also determine your unit’s warranty status by obtaining the complete model number, complete serial number, and date of installation of your water heater and then accessing the “Warranty Verification” information on Rheem Water Heaters' internet website (www.rheem.com) or contacting Rheem's Claims
Department (telephone (800) 621-5622) during normal business hours (in the Central Time Zone) to determine if the Applicable Warranty Period has expired.
If your water heater is “in-warranty”, contact the plumber, or mechanical contractor, that installed it for assistance with the warranty repairs, or replacement, required. Rheem Water Heaters' Technical Service personnel are available to assist you (by telephone at (866) 720-2076) in obtaining “in-warranty” service or to answer your questions about the operation or repair of your water heater during normal business hours (in the Central Time Zone). Be prepared to provide the plumber, mechanical contractor, or Rheem Technical Service person you call with the complete model number, the complete serial number, and the date of installation of your water heater in addition to an explanation of your water heater problem.
If an exact replacement is not available, Rheem will provide you with the current model of your water heater, or component part(s), or a replacement unit with comparable operating features. If government regulations or industry certification or similar standards require the replacement water heater, or replacement component part(s), to have features not found in the defective water heater, or the defective component part(s), you will be charged for the difference in price represented by those required features. If you pay the price difference for those required features and/or to upgrade the size and/or other features available on a replacement new water heater, you will also receive a complete new Limited Warranty (with the full Applicable Warranty Period) for the replacement new water heater.
Rheem reserves the right to inspect, or require the return of, the failed water heater or the defective component part(s). Each “in-warranty” failure water heater must be made available to Rheem (with the rating label and all the component parts intact) in exchange for the replacement water heater. Each defective
“in-warranty” component part to be replaced must be returned to Rheem in exchange for the replacement component part.
Warranty compensation is subject to validation of “in-warranty” coverage by Rheem Claims Department personnel.
• To obtain warranty compensation for an “in-warranty” water heater failure, you must provide Rheem with the failed water heater (with the rating label and all the component parts intact) the complete model number and the complete serial number of the Rheem or Ruud water heater that replaced the failed unit; and the date the original water heater failed. You may also be required to provide documentary proof of the failed water heaters date of installation to establish its
“in-warranty” status.
• To receive warranty compensation for an “in-warranty” defective component part, you must provide Rheem with: the defective component part; the complete model number and the complete serial number of the Rheem or Ruud water heater from which the defective component part was removed; and the date the defective component part failed. You may also be required to provide documentary proof of the date of installation of the Rheem or Ruud water heater from which the defective part was removed – or the date of purchase of the part (If it was purchased separately) – to establish the “in-warranty” status of the defective component part.
• If Rheem determines that the water heater or component part returned to Rheem is free of defects in material and manufacture and/or that it was damaged by improper installation or other cause not covered by this Limited Warranty, the warranty claim for the product, component part and/or labor maybe denied.
Warranty claim documentation should be mailed promptly to Rheem Water Heaters, Claims Department, 1241 Carwood Court, Montgomery, Alabama 36117, or in Canada, 125 Edgeware Rd. Unit 1, Brampton, ON, Canada L6Y 0P5
EXCLUSIVE WARRANTY – LIMITATION OF LIABILITY
THIS LIMITED WARRANTY IS THE SOLE AND EXCLUSIVE WARRANTY PROVIDED IN CONNECTION WITH THIS RHEEM®,
RUUD®, RICHMOND®, PALOMA® AND SURE COMFORT® RESIDENTIAL TANKLESS GAS WATER HEATER UNIT (THE
“WATER HEATER”). No one is authorized to make any other warranties on behalf of Rheem. ANY IMPLIED WARRANTIES, INCLUDING
MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PURPOSE, SHALL NOT EXTEND BEYOND THE APPLICABLE WARRANTY
PERIODS, SPECIFIED PREVIOUSLY. RHEEM’S SOLE LIABILITY, WITH RESPECT TO ANY DEFECT, SHALL BE AS SET FORTH IN
THIS LIMITED WARRANTY, AND ANY CLAIMS FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDING DAMAGE FROM
WATER LEAKAGE) ARE EXCLUDED. Some states do not allow limitations on how long an implied warranty lasts, or for the exclusion of incidental or consequential damages, so the above limitations or exclusions may not apply to you.
This Limited Warranty gives you specific legal rights, and you may also have other rights, which vary from state to state.
DO NOT RETURN THIS WATER HEATER OR PART TO RHEEM WITHOUT A RETURN AUTHORIZATION.
This document is for reference only and does not replace the original warranty document found in the back of the Use and Care manual provided with the tankless water heater.
DO NOT RETURN THIS DOCUMENT TO RHEEM.
KEEP IT WITH YOUR WATER HEATER OR BUSINESS RECORDS.
Name of Owner:_______________________________________________________________________________________________________________
Owner’s Address:_______________________________________________________________________________________________________________
Name of Plumber/
Mechanical Contractor – Installer:__________________________________________________________________________________________________
Address of Plumber/
Mechanical Contractor – Installer :_________________________________________________________________________________________________
Telephone Number of Plumber/
Mechanical Contractor – Installer:_________________________________________________________________________________________________
Date of Water Heater Installation:__________________________________________________________________________________________________
Model Number of Your Water Heater:_______________________________________________________________________________________________
Serial Number of Your Water Heater:_ ______________________________________________________________________________________________
SMARTEC ECONET
TRANSLATOR KIT
Installation Instructions
This water heater is pre-installed with Smartec EcoNet Translator. Refer to below instruction to setup the translator and WiFi module.
CAUTION: Disconnect power before working on the water heater.
Warning: WiFi module needs to be installed indoors.
STAND-ALONE OPERATION SETUP
1. If only one Gas Tankless Water Heater is connected to the EcoNet Bus, you can now start using the SMARTEC EcoNet Translator to monitor and control the water temperature of your Gas Tankless Water Heater through the EcoNet App (see WiFi instructions). Remember to wait 60 seconds before starting operation.
2. The user can enable/disable the water heater and set/view the water outlet temperature using the Remote Control connected to the unit or wirelessly through the EcoNet App.
MANIFOLD OPERATION SETUP
If more than one water heater is connected together in a Manifold configuration continue with this section. Otherwise, skip to Alarms section.
1. Remove front cover from the water heater.
2. To allow the SMARTEC EcoNet Translator to control Gas Tankless Water
Heaters in a manifold configuration, each manifolded unit should be connected to a SMARTEC EcoNet Translator.
3. Connect manifolded units serially using both/any of the Econet ports located on the EcoNet Translator and the provided RJ25 cable.
4. Enter the setup menu by pressing the two buttons simultaneously located on the SMARTEC EcoNet Translator for 5 seconds. If successful, you will see a “1” instead of a “01” on the display.
5. Press the right button to change the number assigned to each water heater. The number displayed will increase with each button press.
6. Each unit in the manifold should be numbered sequentially. This means that if the user has 4 units connected in a manifold mode, then they should be numbered 01, 02, 03 and 04. Maximum number of units supported in manifold is 20.
To return to the main menu press the left button.
7. Connect the Remote Control included with the water heater only to number 01 when in manifold configuration. The remote control connected to number 01 will control all units in manifold.
8. The user can enable/disable the water heaters and set/view the water outlet temperature using the Remote Control connected to number 01 or wirelessly through the App.
Pressing the left button scrolls the menu items. Pressing the right button chooses the menu item and changes the menu choice as follows:
Menu Item Function
Number of Manifold Heaters (1-20), 1 = No manifold operation.
3 Recirculation Mode 0= OFF, 1=ON
The menu will exit after 10 seconds if no buttons are pressed. Changes will be saved upon menu exit.
9. Only unit number “01” will have menu item 2 available. This menu item tells the manifold manager (number 01) how many heaters are connected in the manifold system.
10. Pressing the right button when in menu item 2 will increase the number of manifolded units the manager will detect.
Once all units on the manifold are numbered correctly, the configuration will be completed. Power cycle all units. Wait 60 seconds before starting operation.
* All switches in the water heaters controller must be in the off position.
RECIRCULATION PUMP OPERATION
If you have a recirculation pump installed in your system follow the next steps to setup your system.
MANIFOLD
Use menu item 3 to turn ON recirculation mode only in the water heater unit with number 1 assigned. All other units connected in the manifold are left as is. Power cycle all water heaters in the manifold.
STAND ALONE
Use menu item 3 to turn ON recirculation mode. Power cycle your water heater.
Note: Recirculation mode is intended for setups of 3 or more manifolded units.
HIGH TEMPERATURE SETTING
If you have a water heater chip that allows a higher water temperature set-point (185°F) installed in your unit follow these steps to set it up with the EcoNet translator. The following steps are for stand-alone units and number/instance 01 in a manifold setup.
With unit ON:
1. Change your set-point to 100°F using the remote or the EcoNet App.
Wait 10 seconds.
2. Disconnect translator from unit.
3. Turn off unit by pressing the power button on the remote control.
4. Turn DIP1 switch 4 ON (Refer to the water heater Use & Care Manual).
The remote control starts to blink.
5. Press max button for 2 seconds.
6. Turn DIP1 switch 4 OFF.
7. Press the Power button in your remote control.
8. Connect translator to unit.
9. Wait 60 seconds.
10. Change the set-point to the desired value using the remote control the
EcoNet App.
Note: If you change the set-point to 140 and below you will have to repeat the process again.
For manifold setup it is necessary to complete the following process for each water heater that is not number 01:
1. Disconnect translator from unit.
2. Turn off unit by pressing the power button on the remote control.
3. Turn DIP1 switch 4 ON. The Red LED in the control board starts to blink.
4. Press max button for 2 seconds. Red LED stays solid.
5. Turn DIP1 switch 4 OFF.
6. Disconnect water heater unit from wall power.
7. Connect translator to unit.
8. Plug back water heater unit to power outlet.
ALARMS
If the EcoNet WiFi module is configured correctly, the user will receive a notification in the App regarding the detected alarm.
Additionally the remote control may display the alarms.
When an alarm is detected, the number displayed in the translator will blink.
When this occurs, the user should connect to the App in order to identify the issue that was detected.
To clear warnings or alarms press the left button on the EcoNet translator for 5 seconds until all segments on the LED displays are on. Then release the button and alarms will be cleared.
TROUBLESHOOTING
●
Verify that the WiFi module is connected and properly configured.
● If a fault is detected in any of the water heaters connected to EcoNet, please refer to the EcoNet App in order to troubleshoot any alarms in your water heater.
● If your WiFi signal strength is too weak at your Water Heater’s location, you may still be able to use the WiFi Kit by using a WiFi Range Extender.
Contact your favorite electronics retailer for more information.
●
If connection is lost, verify that the lights in your WiFi module are solid. If not, unplug and plug the power cord to the module.
● Contact customer service if a fault is detected.
Phone: 1-866-720-2076 - Water Heater Customer Service.
1-800-255-2388 - EcoNet Customer Service Number (Module WiFi)
Website: www.Rheem.com/EcoNet
Error Code Description
A100
Unknown Error from the
Tankless Control
A107
S300
S103
S104
S105
A201
A203
A203
Water Detected
Water Sensor Not
Installed
Possible Freezing
Conditions
Service Reminder
Change Water Filter
Translator to Water
Heater Comm.Failure
EcoNet Water Heater
Comm.Failure
Water Heater Comm.
Failure Instance X
Solution
Contact water heater customer service.
There is water present inside the water heater, check for leaks or other sources of water.
Verify the water sensor is connected properly to the
EcoNet translator.
Heat Exchanger temperature is too low.
Friendly reminder to have your water heater serviced. 200 hrs of operation have passed.
Change filter if installed, if not disregard warning.
Verify connection between
EcoNet translator and water heater control board. Reset power to unit.
Verify EcoNet wiring to WiFi module or to another EcoNet translator. Reset power to unit.
In manifold, verify wiring between units. Reset power to all water heaters.
AP18492 (01/17)
STEP 4: Install the power cord.
Install power cord into power jack at bottom of module and plug transformer to a power source.
ECONET WiFi KIT
Installation Instructions
BEFORE YOU BEGIN
The EcoNet WiFi Kit is intended for use with EcoNet Enabled products.
DO NOT attempt to use this kit with other equipment.
The EcoNet WiFi Kit requires a broadband home Internet connection and WiFi network in order to operate. Use a mobile phone or other WiFi capable device to ensure that the home’s WiFi network is accessible from the Water Heater’s location.*
STEP 1: Record the MAC Address.
Locate the MAC Address on the back of your module as depicted in
Figure 1, and record it. You will need this information in the future and may be asked for it during the setup process. Take a digital photo using a mobile device, or write it in the space provided below.
MAC Address: _____-_____-_____-_____-_____-____
Fig. 1
Sample
Media Access Control (MAC)
Address location
STEP 2: Connect the Communication Cable.
Fig. 2
Fig. 2
Remove front cover from the water heater and insert the other end of the Communication Cable into one of the EcoNet port on your EcoNet
Translator.
Exemple
Emplacement de l’adresse
MAC de commande d’accès au support
Ensure that both plugs on the Communication Cable are securely attached as described above.
Remove the protective paper from one side of the Adhesive Tape and affix it to the back of the WiFi Module above the label with the MAC
Address.
Fig. 3
Select a location for attaching the WiFi Module to the indoor location of your preference which does not cause severe tension in the
Communication Cable.
Remove the protective paper from the remaining side of the Adhesive
Tape and press the Module against a clean flat surface of the Water
Heater as depicted in Figure 3 for indoor models.
Fig. 3
Muestra
Ubicación de la dirección del
Control de Acceso a Medios (MAC)
STEP 5: Connecting to the Internet.
After the WiFi Module is installed and the Water Heater is powered, all three LEDs should blink simultaneously, indicating that the module is ready to be configured for use on the home network. [NOTE: In this state the module is operating as a WiFi Access Point.]
Fig. 5
Top LED indicates power and connection to equipment.
Fig. 5
Middle LED indicates
WiFi connection.
Lower LED indicates an active connection to the cloud/server.
The WLAN SETUP button is used to reset the WiFi configuration/connection.
Fig. 5
Le voyant DEL supérieur indique l’alimentation et la connexion à l’équipement.
instructions presented within the app.
Le voyant DEL du milieu indique une connexion WiFi.
continue installation, manually return to the EcoNet app and follow the remaining instructions.
Additional Tip
Le voyant DEL inférieur indique une connexion active au nuage/serveur.
Le bouton WLAN SETUP
(CONFIGURATION DU RÉSEAU
LOCAL SANS FIL) sert à réinitialiser la configuration/ connexion WiFi.
La luz LED superior indica corriente eléctrica y conexión al equipo.
La luz LED central indica conexión por WiFi.
La luz LED inferior indica que hay una conexión activa a la nube/ servidor.
El botón WLAN SETUP se usa para reconfigurar la conexión/ configuración por WiFi.
SMARTEC ECONET
TRANSLATOR KIT
Intrucciones de instalación
Este calentador de agua tiene preinstalado el Smartec EcoNet Translator.
Consulte las instrucciones que siguen a continuación para configurar el
Translator y el módulo WiFi.
Advertencia: el módulo WiFi debe instalarse en interiores.
CONFIGURACIÓN PARA OPERACIÓN INDEPENDIENTE
1. Si hay un solo calentador de agua a gas sin tanque conectado al bus
EcoNet, usted puede comenzar ahora a usar el SMARTEC EcoNet
Translator para monitorear y controlar la temperatura del agua de su calentador de agua a gas sin tanque por medio de la aplicación EcoNet
App (vea instrucciones de WiFi). Espere 60 segundos después de energizar para utilizar su unidad.
2. El usuario puede habilitar/deshabilitar el calentador de agua y establecer/ ver la temperatura de salida del agua por medio del control remoto conectado a la unidad, o de manera inalámbrica a través de la EcoNet
App.
CONFIGURACIÓN DE LA OPERACIÓN DE MANIFOLD
Si hay más de un calentador de agua conectado conjuntamente en una configuración de manifold, continúe con esta sección. De lo contrario,pase a la sección Alarmas.
1. Retire la cubierta frontal del calentador de agua.
2. Para permitir que el SMARTEC EcoNet Translator controle los calentadores de agua a gas sin tanque en una configuración de manifold, cada unidad acoplada debe conectarse a un SMARTEC EcoNet
Translator.
3. Conecte las unidades acopladas en serie mediante ambos o alguno de los puertos EcoNet ubicados en el EcoNet Translator y el cable RJ25 provisto.
4. Ingrese al menú de configuración oprimiendo simultáneamente los dos botones ubicados en el SMARTEC EcoNet Translator durante 5 segundos. Si el funcionamiento es correcto, usted verá un “1” en lugar de un “01” en la pantalla.
5. Oprima el botón derecho para cambiar el número asignado a cada calentador de agua. El número visualizado aumentará con cada pulsación del botón.
6. Cada unidad del manifold debe numerarse de manera secuencial. Esto significa que si el usuario tiene 4 unidades conectadas en modo de manifold, deben tener las numeraciones 01, 02, 03 y 04. La cantidad máxima de unidades conectadas en un manifold es 20.
Para volver al menú principal, oprima el botón izquierdo.
7. Conecte el Control Remoto incluido con el calentador de agua al número
01 cuando esté en la configuración de manifold. El control remoto conectado al número 01 controlará todas las unidades del manifold.
8. El usuario puede habilitar/deshabilitar los calentadores de agua y establecer/ver la temperatura de salida del agua por medio del control remoto conectado al número 01, o de manera inalámbrica a través de la App.
Al oprimir el botón izquierdo se recorren los ítems del menú. Al oprimir el botón derecho se elige el ítem del menú y se cambia la selección del menú, como sigue:
Item del menú Función
Cantidad de calentadores acoplados (1-20),
1= no hay operación de colector.
3 Modo de Recirculacion 0=Apagado, 1=encendido
Si no se oprimen botones durante 10 segundos, se sale del menú. Al salir del menú se guardan los cambios.
9. Solo la unidad número “01” tendrá disponible el ítem de menú 2. Este
ítem de menú le dice al administrador de manifold (número 01) cuántos calentadores están conectados en el sistema de manifold.
10. Al oprimir el botón derecho cuando se está en el ítem de menú 2, aumenta la cantidad de unidades acopladas que el administrador detectará.
Una vez que todas las unidades del manifold estén correctamente numeradas, la configuración ha finalizado.
* Todos los switches en los controladores de los calentadores de agua tienen que estar en la posición de apagado.
OPERACION CON BOMBA DE RECIRCULACION
Si tiene instalada una bomba de recirculacion, siga los siguientes pasos para configurar su Sistema.
MANIFOLD
Use el item del menú 3 para encender el modo de recirculación solo con el calentador de agua asignado al numero 01. Todas las otras unidades conectadas en manifold se quedan sin cambio alguno. Desconecte y reconecte la energia en todos los calentadores de agua en el manifold.
OPERACION INDEPENDIENTE
Use el item del menú 3 para encender el modo de recirculación.
Desconecte y reconecte la energia en todos los calentadores de agua en el manifold.
Nota: El modo de recirculación esta diseñado para configuraciones de
3 o más unidades en manifold.
CONFIGURACION DE TEMPERATURA ALTA
Si tiene un chip para calentador de agua que le permita establecer una temperatura de salida alta (185°F) instalado en su unidad, entonces siga estos pasos para configurarlo con su EcoNet translator. Los siguientes pasos son para unidades individuales y para la unidad con la instancia/ numero 01 en configuracion manifold.
Con el calentador de agua encendido:
Para configurar el manifold es necesario completer el siguiente proceso para cada calentador de agua que no sea el número/instancia 01:
1. Desconecte el EcoNet translator del calentador de agua.
2. Apague la unidad presionando el botton the power en el control remote.
3. Cambie a encendido el switch 4 del DIP1 en la tarjeta de control de su calentador de agua (Refierase al Manual de Uso y Cuidado de su calentador de agua). El LED rojo en la tarjeta de control empieza a parapadear.
4. Presiona el boton MAX en la tarjeta de control del calentador de agua por
2 segundos. El LED rojo se mantiene encendido.
5. Cambie a apagado el switch 4 del DIP1.
6. Desconecte el calentador de agua de la alimentacion de la pared.
7. Conecte el EcoNet translator de vuelta al calentador de agua.
8. Conecte el calentador de agua a la alimentacion de la pared.
ALARMAS
Si el módulo EcoNet WiFi está configurado correctamente, el usuario recibirá una notificación en la App respecto a la alarma detectada.
Además, el control remoto puede exhibir las alarmas.
Cuando se detecta una alarma, el número que se visualiza en el Translator destellará. Cuando esto ocurre, el usuario debe conectarse a la App para identificar el problema que se detectó.
Para limpiar las alarmas presione el botón izquierdo en el traductor EcoNet por 5 segundos hasta que todos los segmentos en los displays LED estén encendidos. Después suelte el botón y las alarmas serán limpiadas.
LOCALIZACIÓN DE FALLAS
● Verifique que el módulo WiFi esté conectado y correctamente configurado.
●
Si se detecta una falla en cualquiera de los calentadores de agua conectados al EcoNet, consulte la App de EcoNet a fin de investigar las alarmas de su calentador de agua.
● Si la intensidad de su señal de WiFi es demasiado débil en la ubicación de su calentador de agua, tiene la posibilidad de seguir utilizando el
Kit de WiFi mediante el uso de un Extensor de rango de WiFi. Para obtener más información, contacte con su tienda minorista de electrónica preferida.
●
Si se pierde la conexión, verifique que las luces de su módulo WiFi estén constantemente encendidas. Si no, desenchufe y vuelva a enchufar el cable de alimentación eléctrica al módulo.
● Si detecta una falla, contacte con el servicio al cliente.
Teléfono: 1-866-720-2076 - Servicio al cliente de calentadores de agua.
Sitio Web:
1-800-255-2388 - Número de Servicio al cliente de EcoNet (Modulo WiFi) www.Rheem.com/EcoNet
Código de
Error
A100
A107
S300
S103
S104
S105
A201
A203
A203
Descripción
Error desconocido del controlador tankless
Agua detectada
Sensor de agua no instalado
Posibles condiciones de congelamiento
Recordatorio de servicio
Falla de comunicación del traductor al calentador de agua
Falla de comunicación
EcoNet
Falla de comunicación en calentador de agua instancia X
Solución
Contacte al servicio al cliente de calentadores de agua.
Hay agua presente dentro del calentador de agua, busque fugas u otras fuentes de agua.
Verifique que el sensor de agua esta conectado al traductor EcoNet.
La temperatura del Intercambiador de Calor es muy baja.
Recordatorio de servicio.
200 horas de operacion han pasado.
Verifique la conexión entre traductor EcoNet y el calentador de agua. Reinicie la unidad.
Verifique el cableado al modulo de WiFi o a otro traductor EcoNet.
Reinicie la unidad.
En colector, verifique el cableado entre las unidades.
Reinicie todas las unidades.
2. Desconecte el EcoNet translator del calentador de agua.
3. Apague la unidad presionando el botton the power en el control remote.
4. Cambie a encendido el switch 4 del DIP1 en la tarjeta de control de su calentador de agua (Refierase al Manual de Uso y Cuidado de su calentador de agua). El control remoto empieza a parapadear.
5. Presiona el boton MAX en la tarjeta de control del calentador de agua por
2 segundos. El control remote deja de parpadear.
6. Cambie a apagado el switch 4 del DIP1.
7. Presione el boton de power en el control remote.
8. Conecte el EcoNet translator de vuelta al calentador de agua.
9 Espere 60 segundos.
10. Cambie la temperatura deseada en el control remoto o usando la
Aplicación EcoNet.
Nota: Si cambia la temperatura a 140°F o menos, tendra que repetir el proceso de nueva cuenta.
SMARTEC ECONET
TRANSLATOR KIT
Installation Instructions
This water heater is pre-installed with Smartec EcoNet Translator. Refer to below instruction to setup the translator and WiFi module.
CAUTION: Disconnect power before working on the water heater.
Warning: WiFi module needs to be installed indoors.
STAND-ALONE OPERATION SETUP
1. If only one Gas Tankless Water Heater is connected to the EcoNet Bus, you can now start using the SMARTEC EcoNet Translator to monitor and control the water temperature of your Gas Tankless Water Heater through the EcoNet App (see WiFi instructions). Remember to wait 60 seconds before starting operation.
2. The user can enable/disable the water heater and set/view the water outlet temperature using the Remote Control connected to the unit or wirelessly through the EcoNet App.
MANIFOLD OPERATION SETUP
If more than one water heater is connected together in a Manifold configuration continue with this section. Otherwise, skip to Alarms section.
1. Remove front cover from the water heater.
2. To allow the SMARTEC EcoNet Translator to control Gas Tankless Water
Heaters in a manifold configuration, each manifolded unit should be connected to a SMARTEC EcoNet Translator.
3. Connect manifolded units serially using both/any of the Econet ports
4. Enter the setup menu by pressing the two buttons simultaneously located on the SMARTEC EcoNet Translator for 5 seconds. If successful, you will see a “1” instead of a “01” on the display.
5. Press the right button to change the number assigned to each water heater. The number displayed will increase with each button press.
6. Each unit in the manifold should be numbered sequentially. This means that if the user has 4 units connected in a manifold mode, then they should be numbered 01, 02, 03 and 04. Maximum number of units supported in manifold is 20.
To return to the main menu press the left button.
7. Connect the Remote Control included with the water heater only to number 01 when in manifold configuration. The remote control connected to number 01 will control all units in manifold.
8. The user can enable/disable the water heaters and set/view the water outlet temperature using the Remote Control connected to number 01 or wirelessly through the App.
Pressing the left button scrolls the menu items. Pressing the right button chooses the menu item and changes the menu choice as follows:
Menu Item Function
Number of Manifold Heaters (1-20), 1 = No manifold operation.
3 Recirculation Mode 0= OFF, 1=ON
The menu will exit after 10 seconds if no buttons are pressed. Changes will be saved upon menu exit.
9. Only unit number “01” will have menu item 2 available. This menu item tells the manifold manager (number 01) how many heaters are connected in the manifold system.
10. Pressing the right button when in menu item 2 will increase the number of manifolded units the manager will detect.
Once all units on the manifold are numbered correctly, the configuration will be completed. Power cycle all units. Wait 60 seconds before starting operation.
* All switches in the water heaters controller must be in the off position.
RECIRCULATION PUMP OPERATION
If you have a recirculation pump installed in your system follow the next steps to setup your system.
MANIFOLD
Use menu item 3 to turn ON recirculation mode only in the water heater unit with number 1 assigned. All other units connected in the manifold are left as is. Power cycle all water heaters in the manifold.
STAND ALONE
Use menu item 3 to turn ON recirculation mode. Power cycle your water heater.
Note: Recirculation mode is intended for setups of 3 or more manifolded units.
HIGH TEMPERATURE SETTING
If you have a water heater chip that allows a higher water temperature set-point (185°F) installed in your unit follow these steps to set it up with the EcoNet translator. The following steps are for stand-alone units and number/instance 01 in a manifold setup.
With unit ON:
1. Change your set-point to 100°F using the remote or the EcoNet App.
Wait 10 seconds.
2. Disconnect translator from unit.
3. Turn off unit by pressing the power button on the remote control.
4. Turn DIP1 switch 4 ON (Refer to the water heater Use & Care Manual).
The remote control starts to blink.
5. Press max button for 2 seconds.
6. Turn DIP1 switch 4 OFF.
7. Press the Power button in your remote control.
8. Connect translator to unit.
9. Wait 60 seconds.
10. Change the set-point to the desired value using the remote control the
EcoNet App.
7. Connect translator to unit.
8. Plug back water heater unit to power outlet.
ALARMS
If the EcoNet WiFi module is configured correctly, the user will receive a notification in the App regarding the detected alarm.
Additionally the remote control may display the alarms.
When an alarm is detected, the number displayed in the translator will blink.
When this occurs, the user should connect to the App in order to identify the issue that was detected.
To clear warnings or alarms press the left button on the EcoNet translator for 5 seconds until all segments on the LED displays are on. Then release the button and alarms will be cleared.
TROUBLESHOOTING
●
Verify that the WiFi module is connected and properly configured.
●
If a fault is detected in any of the water heaters connected to EcoNet, please refer to the EcoNet App in order to troubleshoot any alarms in your water heater.
● If your WiFi signal strength is too weak at your Water Heater’s location, you may still be able to use the WiFi Kit by using a WiFi Range Extender.
Contact your favorite electronics retailer for more information.
● If connection is lost, verify that the lights in your WiFi module are solid. If not, unplug and plug the power cord to the module.
●
Contact customer service if a fault is detected.
Phone: 1-866-720-2076 - Water Heater Customer Service.
1-800-255-2388 - EcoNet Customer Service Number (Module WiFi)
Website: www.Rheem.com/EcoNet
Error Code Description
A100
Unknown Error from the
Tankless Control
A107
S300
S103
S104
S105
A201
A203
A203
Water Detected
Water Sensor Not
Installed
Possible Freezing
Conditions
Service Reminder
Change Water Filter
Translator to Water
Heater Comm.Failure
EcoNet Water Heater
Comm.Failure
Water Heater Comm.
Failure Instance X
Solution
Contact water heater customer service.
There is water present inside the water heater, check for leaks or other sources of water.
Verify the water sensor is connected properly to the
EcoNet translator.
Heat Exchanger temperature is too low.
Friendly reminder to have your water heater serviced. 200 hrs of operation have passed.
Change filter if installed, if not disregard warning.
Verify connection between
EcoNet translator and water heater control board. Reset power to unit.
Verify EcoNet wiring to WiFi module or to another EcoNet translator. Reset power to unit.
In manifold, verify wiring between units. Reset power to all water heaters.
For manifold setup it is necessary to complete the following process for each water heater that is not number 01:
1. Disconnect translator from unit.
2. Turn off unit by pressing the power button on the remote control.
3. Turn DIP1 switch 4 ON. The Red LED in the control board starts to blink.
4. Press max button for 2 seconds. Red LED stays solid.
5. Turn DIP1 switch 4 OFF.
6. Disconnect water heater unit from wall power.
ECONET WiFi KIT
Installation Instructions
BEFORE YOU BEGIN
●
The EcoNet WiFi Kit is intended for use with EcoNet Enabled products.
DO NOT attempt to use this kit with other equipment.
● The EcoNet WiFi Kit requires a broadband home Internet connection and WiFi network in order to operate. Use a mobile phone or other WiFi capable device to ensure that the home’s WiFi network is accessible from the Water Heater’s location.*
Middle LED indicates
WiFi connection.
Lower LED indicates an active connection to the cloud/server.
The WLAN SETUP button is used to reset the WiFi configuration/connection.
STEP 1: Record the MAC Address.
● Locate the MAC Address on the back of your module as depicted in
Figure 1, and record it. You will need this information in the future and may be asked for it during the setup process. Take a digital photo using a mobile device, or write it in the space provided below.
MAC Address: _____-_____-_____-_____-_____-____
Fig. 1
●
Fig. 5
Le voyant DEL supérieur
● indique l’alimentation et la
● connexion à l’équipement.
instructions presented within the app.
Le voyant DEL du milieu indique une connexion WiFi.
continue installation, manually return to the EcoNet app and follow the remaining instructions.
Additional Tip
Le voyant DEL inférieur indique une connexion active au nuage/serveur.
To repeat the setup process or change the Internet
Le bouton WLAN SETUP
(CONFIGURATION DU RÉSEAU
LOCAL SANS FIL) sert à réinitialiser la configuration/ connexion WiFi.
Sample
Media Access Control (MAC)
Address location
STEP 2: Connect the Communication Cable.
●
Fig. 1
Fig. 2
Fig. 2
● Remove front cover from the water heater and insert the other end of the Communication Cable into one of the EcoNet port on your EcoNet
Translator.
● Replace front cover and power the unit.
au support
Exemple
Emplacement de l’adresse
MAC de commande d’accès
●
Ensure that both plugs on the Communication Cable are securely attached as described above.
●
Fig. 1 affix it to the back of the WiFi Module above the label with the MAC
Address.
Fig. 3
● Select a location for attaching the WiFi Module to the indoor location of your preference which does not cause severe tension in the
Communication Cable.
●
Remove the protective paper from the remaining side of the Adhesive
Tape and press the Module against a clean flat surface of the Water
Heater as depicted in Figure 3 for indoor models.
Fig. 3
Muestra
Ubicación de la dirección del
Control de Acceso a Medios (MAC)
●
WiFi module and power connector need to be located indoor.
STEP 4: Install the power cord.
●
Install power cord into power jack at bottom of module and plug transformer to a power source.
STEP 5: Connecting to the Internet.
● After the WiFi Module is installed and the Water Heater is powered, all three LEDs should blink simultaneously, indicating that the module is ready to be configured for use on the home network. [NOTE: In this state the module is operating as a WiFi Access Point.]
Fig. 5
Top LED indicates power and connection to equipment.
Fig. 5
La luz LED superior indica corriente eléctrica y conexión al equipo.
La luz LED central indica conexión por WiFi.
La luz LED inferior indica que hay una conexión activa a la nube/ servidor.
El botón WLAN SETUP se usa para reconfigurar la conexión/ configuración por WiFi.
SMARTEC ECONET
TRANSLATOR KIT
Intrucciones de instalación
Este calentador de agua tiene preinstalado el Smartec EcoNet Translator.
Consulte las instrucciones que siguen a continuación para configurar el
Translator y el módulo WiFi.
ATENCIÓN: desconecte la alimentación eléctrica antes de trabajar en el calentador de agua.
Advertencia: el módulo WiFi debe instalarse en interiores.
CONFIGURACIÓN PARA OPERACIÓN INDEPENDIENTE
1. Si hay un solo calentador de agua a gas sin tanque conectado al bus
EcoNet, usted puede comenzar ahora a usar el SMARTEC EcoNet
Translator para monitorear y controlar la temperatura del agua de su calentador de agua a gas sin tanque por medio de la aplicación EcoNet
App (vea instrucciones de WiFi). Espere 60 segundos después de energizar para utilizar su unidad.
2. El usuario puede habilitar/deshabilitar el calentador de agua y establecer/ ver la temperatura de salida del agua por medio del control remoto conectado a la unidad, o de manera inalámbrica a través de la EcoNet
App.
CONFIGURACIÓN DE LA OPERACIÓN DE MANIFOLD
Si hay más de un calentador de agua conectado conjuntamente en una configuración de manifold, continúe con esta sección. De lo contrario,pase a la sección Alarmas.
1. Retire la cubierta frontal del calentador de agua.
2. Para permitir que el SMARTEC EcoNet Translator controle los calentadores de agua a gas sin tanque en una configuración de manifold, cada unidad acoplada debe conectarse a un SMARTEC EcoNet
Translator.
3. Conecte las unidades acopladas en serie mediante ambos o alguno de los puertos EcoNet ubicados en el EcoNet Translator y el cable RJ25 provisto.
4. Ingrese al menú de configuración oprimiendo simultáneamente los dos botones ubicados en el SMARTEC EcoNet Translator durante 5 segundos. Si el funcionamiento es correcto, usted verá un “1” en lugar de un “01” en la pantalla.
5. Oprima el botón derecho para cambiar el número asignado a cada calentador de agua. El número visualizado aumentará con cada pulsación del botón.
6. Cada unidad del manifold debe numerarse de manera secuencial. Esto significa que si el usuario tiene 4 unidades conectadas en modo de manifold, deben tener las numeraciones 01, 02, 03 y 04. La cantidad máxima de unidades conectadas en un manifold es 20.
Para volver al menú principal, oprima el botón izquierdo.
7. Conecte el Control Remoto incluido con el calentador de agua al número
01 cuando esté en la configuración de manifold. El control remoto conectado al número 01 controlará todas las unidades del manifold.
8. El usuario puede habilitar/deshabilitar los calentadores de agua y establecer/ver la temperatura de salida del agua por medio del control remoto conectado al número 01, o de manera inalámbrica a través de la App.
Al oprimir el botón izquierdo se recorren los ítems del menú. Al oprimir el botón derecho se elige el ítem del menú y se cambia la selección del menú, como sigue:
Item del menú Función
Cantidad de calentadores acoplados (1-20),
1= no hay operación de colector.
3 Modo de Recirculacion 0=Apagado, 1=encendido
Si no se oprimen botones durante 10 segundos, se sale del menú. Al salir del menú se guardan los cambios.
9. Solo la unidad número “01” tendrá disponible el ítem de menú 2. Este
ítem de menú le dice al administrador de manifold (número 01) cuántos calentadores están conectados en el sistema de manifold.
10. Al oprimir el botón derecho cuando se está en el ítem de menú 2, aumenta la cantidad de unidades acopladas que el administrador detectará.
Una vez que todas las unidades del manifold estén correctamente numeradas, la configuración ha finalizado.
* Todos los switches en los controladores de los calentadores de agua tienen que estar en la posición de apagado.
OPERACION CON BOMBA DE RECIRCULACION
Si tiene instalada una bomba de recirculacion, siga los siguientes pasos para configurar su Sistema.
MANIFOLD
Use el item del menú 3 para encender el modo de recirculación solo con el calentador de agua asignado al numero 01. Todas las otras unidades conectadas en manifold se quedan sin cambio alguno. Desconecte y reconecte la energia en todos los calentadores de agua en el manifold.
OPERACION INDEPENDIENTE
Use el item del menú 3 para encender el modo de recirculación.
Desconecte y reconecte la energia en todos los calentadores de agua en el manifold.
Nota: El modo de recirculación esta diseñado para configuraciones de
3 o más unidades en manifold.
CONFIGURACION DE TEMPERATURA ALTA
Si tiene un chip para calentador de agua que le permita establecer una temperatura de salida alta (185°F) instalado en su unidad, entonces siga estos pasos para configurarlo con su EcoNet translator. Los siguientes pasos son para unidades individuales y para la unidad con la instancia/ numero 01 en configuracion manifold.
Con el calentador de agua encendido:
1. Cambie el set-point de temperatura a 100°F usando el control remoto o la Aplicación EcoNet. Espere 10 segundos.
2. Desconecte el EcoNet translator del calentador de agua.
3. Apague la unidad presionando el botton the power en el control remote.
4. Cambie a encendido el switch 4 del DIP1 en la tarjeta de control de su calentador de agua (Refierase al Manual de Uso y Cuidado de su calentador de agua). El control remoto empieza a parapadear.
5. Presiona el boton MAX en la tarjeta de control del calentador de agua por
2 segundos. El control remote deja de parpadear.
6. Cambie a apagado el switch 4 del DIP1.
7. Presione el boton de power en el control remote.
8. Conecte el EcoNet translator de vuelta al calentador de agua.
9 Espere 60 segundos.
Para configurar el manifold es necesario completer el siguiente proceso para cada calentador de agua que no sea el número/instancia 01:
1. Desconecte el EcoNet translator del calentador de agua.
2. Apague la unidad presionando el botton the power en el control remote.
3. Cambie a encendido el switch 4 del DIP1 en la tarjeta de control de su calentador de agua (Refierase al Manual de Uso y Cuidado de su calentador de agua). El LED rojo en la tarjeta de control empieza a parapadear.
4. Presiona el boton MAX en la tarjeta de control del calentador de agua por
2 segundos. El LED rojo se mantiene encendido.
5. Cambie a apagado el switch 4 del DIP1.
6. Desconecte el calentador de agua de la alimentacion de la pared.
7. Conecte el EcoNet translator de vuelta al calentador de agua.
8. Conecte el calentador de agua a la alimentacion de la pared.
ALARMAS
Si el módulo EcoNet WiFi está configurado correctamente, el usuario recibirá una notificación en la App respecto a la alarma detectada.
Además, el control remoto puede exhibir las alarmas.
Cuando se detecta una alarma, el número que se visualiza en el Translator destellará. Cuando esto ocurre, el usuario debe conectarse a la App para identificar el problema que se detectó.
Para limpiar las alarmas presione el botón izquierdo en el traductor EcoNet por 5 segundos hasta que todos los segmentos en los displays LED estén encendidos. Después suelte el botón y las alarmas serán limpiadas.
LOCALIZACIÓN DE FALLAS
●
Verifique que el módulo WiFi esté conectado y correctamente configurado.
● Si se detecta una falla en cualquiera de los calentadores de agua conectados al EcoNet, consulte la App de EcoNet a fin de investigar las alarmas de su calentador de agua.
●
Si la intensidad de su señal de WiFi es demasiado débil en la ubicación de su calentador de agua, tiene la posibilidad de seguir utilizando el
Kit de WiFi mediante el uso de un Extensor de rango de WiFi. Para obtener más información, contacte con su tienda minorista de electrónica preferida.
● Si se pierde la conexión, verifique que las luces de su módulo WiFi estén constantemente encendidas. Si no, desenchufe y vuelva a enchufar el cable de alimentación eléctrica al módulo.
●
Si detecta una falla, contacte con el servicio al cliente.
Teléfono: 1-866-720-2076 - Servicio al cliente de calentadores de agua.
1-800-255-2388 - Número de Servicio al cliente de EcoNet (Modulo WiFi)
Sitio Web: www.Rheem.com/EcoNet
Código de
Error
A100
A107
S300
S103
S104
S105
A201
A203
A203
Descripción Solución
Error desconocido del controlador tankless
Agua detectada
Sensor de agua no instalado
Posibles condiciones de congelamiento
Recordatorio de servicio
Contacte al servicio al cliente de calentadores de agua.
Hay agua presente dentro del calentador de agua, busque fugas u otras fuentes de agua.
Verifique que el sensor de agua esta conectado al traductor EcoNet.
La temperatura del Intercambiador de Calor es muy baja.
Recordatorio de servicio.
200 horas de operacion han pasado.
Falla de comunicación del traductor al calentador de agua
Falla de comunicación
EcoNet
Falla de comunicación en calentador de agua instancia X
Verifique la conexión entre traductor EcoNet y el calentador de agua. Reinicie la unidad.
Verifique el cableado al modulo de WiFi o a otro traductor EcoNet.
Reinicie la unidad.
En colector, verifique el cableado entre las unidades.
Reinicie todas las unidades.
Nota: Si cambia la temperatura a 140°F o menos, tendra que repetir el proceso de nueva cuenta.
AP18492 (01/17)
Fig. 5
Top LED indicates power and connection to equipment.
Middle LED indicates
WiFi connection.
Lower LED indicates an active connection to the cloud/server.
The WLAN SETUP button is used to reset the WiFi configuration/connection.
Fig. 5
Le voyant DEL supérieur indique l’alimentation et la connexion à l’équipement.
Le voyant DEL du milieu indique une connexion WiFi.
Fig. 5
Top LED indicates power and connection to equipment.
Fig. 1
ECONET WiFi KIT
Intrucciones de instalación
ANTES DE COMENZAR
● El Kit de WiFi EcoNet está diseñado para su uso con productos habilitados para EcoNet. NO intente utilizar este kit con otros equipos.
●
El Kit de WiFi EcoNet requiere para operar una red de WiFi y conexión a Internet doméstica de banda ancha. Utilice un teléfono celular u otro dispositivo compatible con WiFi para asegurarse de que la red de WiFi del hogar esté accesible desde la ubicación del calentador de agua.*
Sample
Media Access Control (MAC)
Address location
Fig. 1
Exemple
●
MAC de commande d’accès au support foto digital con un dispositivo móvil, o escríbala en el espacio siguiente.
Dirección MAC: _____-_____-_____-_____-_____-____
Fig. 1
Muestra
Ubicación de la dirección del
Control de Acceso a Medios (MAC)
PASO 2: Conecte el cable de comunicación.
● Inserte un extremo del cable de comunicación en el conector hembra que se encuentra en el fondo del módulo WiFi, como se ilustra en la Figura 2.
Fig. 2
Fig. 2
● Retire la cubierta frontal del calentador de agua e inserte el otro extremo del cable de comunicación en uno de los puertos EcoNet de su EcoNet
Translator.
●
Vuelva a colocar la cubierta frontal y energice la unidad.
PASO 3: Haga la conexión permanente del módulo WiFi.
● Asegúrese de que ambos enchufes del cable de comunicación estén conectados firmemente, como se describió antes.
●
Fig. 3
●
Seleccione una ubicación para fijar el módulo WiFi en la ubicación interior de su preferencia que no cause una tensión severa en el cable de comunicación.
● Retire el papel protector del lado restante de la cinta adhesiva, y oprima el módulo contra una superficie plana y limpia del calentador de agua, como se ilustra en la Figura 3 de modelos para interiores.
Fig. 3
● El módulo WiFi y el conector de alimentación deben colocarse en interiores.
PASO 4: Instale el cable de alimentación.
● Instale el cable de alimentación en el conector hembra de alimentación que está en el fondo del módulo, y enchufe el transformador a una fuente de alimentación.
Le voyant DEL inférieur indique une connexion active au nuage/serveur.
●
Le bouton WLAN SETUP
(CONFIGURATION DU RÉSEAU
LOCAL SANS FIL) sert à réinitialiser la configuration/
En este estado, el módulo está funcionando como Punto de acceso de
WiFi].
connexion WiFi.
Fig. 5
SMARTEC ECONET
TRADUCTEUR KIT
Instructions d’installation
Ce chauffe-eau comporte un traducteur SMARTEC EcoNet installé à l’avance. Référez-vous aux instructions qui suivent pour la mise en œuvre du traducteur et du module WiFi.
La luz LED superior indica corriente eléctrica y conexión al equipo.
ATTENTION : Débranchez l’alimentation électrique avant d’intervenir sur le chauffe-eau.
La luz LED central indica conexión por WiFi.
Avertissement : Le module WIFI a besoin d’être installé à l’intérieur.
MISE EN SERVICE EN AUTONOME
La luz LED inferior indica que hay una conexión activa a la nube/ servidor.
1. Si un seul chauffe-eau à gaz sans réservoir est connecté au bus EcoNet, vous pouvez maintenant démarrer l’utilisation du traducteur SMARTEC
EcoNet pour surveiller et contrôler la température de l’eau de ce chauffeeau via l’application EcoNet (voir les instructions pour WiFi).Attendre 60 secondes apies la mise sous tension pour utiliser votre appareil.
El botón WLAN SETUP se usa para reconfigurar la conexión/ configuración por WiFi.
2. L’utilisateur peut activer/désactiver le chauffe-eau et régler/visualiser la température de l’eau en sortie à l’aide de la télécommande branchée sur l’appareil ou en liaison sans fil par l’application EcoNet.
MISE EN SERVICE AVEC COLLECTEUR
● Si todavía no lo ha hecho, descargue la aplicación gratuita EcoNet App del Apple App Store o Google Play Store.
Si plusieurs chauffe-eau sont interconnectés en configuration de collecteur, poursuivez avec cette section. Sinon vous pouvez passer directement à la section sur les Alertes.
●
Asegúrese de tener la dirección MAC que capturó en el Paso 1 anterior.
● Mientras esté cerca del módulo WiFi, abra la aplicación EcoNet y siga las instrucciones presentadas dentro de la aplicación.
NOTA: Algunos dispositivos móviles pueden fallar en el reinicio de la aplicación EcoNet después de realizar el primer paso de la conexión a la red. A fin de continuar la instalación, regrese manualmente a la aplicación EcoNet y siga las instrucciones restantes.
Consejo adicional
1. Ôtez le couvercle frontal du chauffe-eau.
2. Pour permettre au traducteur SMARTEC EcoNet de contrôler des chauffe-eau à gaz sans réservoir dans une configuration à collecteur, chaque appareil connecté doit être relié à un traducteur SMARTEC
EcoNet.
3. Reliez les chauffe-eau du même collecteur en série en utilisant un ou les deux ports EcoNet situés sur le traducteur EcoNet et le câble RJ25 fourni.
Para repetir el proceso de configuración o cambiar la configuración de conexión a Internet en cualquier momento, no tiene más que oprimir el botón
CONFIGURACIÓN DE WLAN (WLAN SETUP) del módulo WiFi. Esto hará regresar el módulo a sus valores predeterminados de fábrica. Una vez oprimido el botón, los tres LED comenzarán a destellar simultáneamente, indicando que el módulo se ha reiniciado.
4. Entrez dans le menu de configuration en appuyant en même temps sur les deux boutons du traducteur SMARTEC EcoNet pendant 5 secondes.
Normalement vous devrez voir “1” au lieu de “01” sur l’affichage.
5. Appuyez sur le bouton de droite pour modifier le numéro attribué à chaque chauffe-eau. Le numéro affiché va augmenter à chaque appui sur le bouton.
6. EChaque chauffe-eau sur le collecteur doit être numéroté en séquence.
Cela veut dire que si l’utilisateur a 4 chauffe-eau interconnectés en mode par collecteur, ils doivent être numérotés respectivement 01, 02, 03 et
04. Le nombre maximal de chauffe-eau sur un même collecteur est de 20.
Pour revenir au menu principal appuyez sur le bouton de gauche.
7. Connectez la télécommande incluse avec le chauffe-eau uniquement sur l’appareil numéro 01 dans cette configuration de collecteur. Cette télécommande du 01 va contrôler tous les chauffe-eau interconnectés.
8. L’utilisateur peut activer/désactiver le chauffe-eau et régler/visualiser la température de l’eau en sortie à l’aide de la télécommande branchée sur l’appareil 01 ou en liaison sans fil par l’application EcoNet.
L’appui sur le bouton de gauche fait défiler les articles du menu. L’appui sur le bouton de droite sélectionne l’article du menu et modifie le choix du menu comme suit:
Rubrique du menu Fonction
Nombre de chauffe-eau au collecteur
(1-20), 1 = Pas de fonctionnement en mode collecteur
3 Mode de Recirculation 0= éteindre, 1=allumer
Vous sortez du menu après 10 secondes s’il n’y a pas eu d’action sur un des boutons. Les changements seront sauvegardés dès la sortie du menu.
9. Seul le chauffe-eau numéro 01 aura l’article 2 du menu de disponible.
Cette rubrique du menu indique au gestionnaire du collecteur (numéro
01) combien de chauffe-eau sont connectés au système de collecteur.
10. L’appui sur le bouton de droite en étant à la rubrique 2 du menu augmentera le nombre d’appareils interconnectés que le gestionnaire détectera.
Une fois que tous les chauffe-eau sur le collecteur sont correctement numérotés, la configuration sera terminée, redémarrez votre systéme et attendre 60 secondes avant de commencer.
* Tous les interrupteurs des régulateurs de chauffe-eau doivent être en position d’arrêt.
INSTALLATION AVEC POMPE DE RECIRCULATION
Si votre système de production et de distribution d’eau chaude est équipé d’une pompe de recirculation, veuillez configurer votre chauffe-eau selon la procédure qui suit.
CHAUFFE-EAU EN PARALLÈLE (3 et +)
Utiliser l’option de menu 3 pour activer le mode de recirculation, seulement sur votre chauffe-eau auquel a été assignée la position
1. Ne touchez pas aux micro-interrupteurs des autres appareils de votre groupe de chauffe-eau. Une fois la modification effectuée, coupez l’alimentation électrique (prise murale) et réalimentez tous les chauffe-eau de votre groupe.
CHAUFFE-EAU INDIVIDUE
Utiliser l’option de menu 3 pour activer le mode de recirculation.
Une fois la modification effectuée, coupez l’alimentation électrique
(prise murale) du chauffe-eau et réalimentez-le.
Remarque: Le mode de recirculation est destiné à des configurations de 3 unités ou plus.
SÉLECTION DU RÉGLAGE HAUTE TEMPÉRATURE
Si votre chauffe-eau est équipé d’une carte commerciale qui est en mesure de produire de l’eau chaude pour la désinfection (à une température de 85°C/185°F), suivez la procédure qui suit pour configurer l’interface traducteur EcoNet. La procédure qui suit concerne les chauffe-eau individuel et votre chauffe-eau en parallèle auquel a été assignée la position 1.
Alors que le chauffe-eau est alimenté en électricité:
1. Changez la température de consigne à 100 ° F à l’aide de la télécommande ou l’application EcoNet. Attendre 10 secondes.
2. Déconnectez le traducteur du chauffe-eau.
3. Mettez le chauffe-eau à l’arrêt en appuyant sur le bouton d’alimentation de la télécommande murale.
4. Sur la carte électronique de votre chauffe-eau, déplacer à la position ON le micro-interrupteur 4 de la baguette DIP1 (reportezvous au manuel d’utilisation et d’entretien de votre chauffe-eau). La télécommande se met à clignoter.
5. Maintenez le bouton Max enfoncé pendant 2 secondes.
6. Déplacez à la position OFF le micro-interrupteur 4 de la baguette DIP1.
7. Appuyez sur le bouton d’alimentation de la télécommande.
8. Connectez le contrôleur traducteur au chauffe-eau.
9. Attendez pendant 60 secondes.
10. Changez la température de consigne jusqu’à la valeur voulue.
Note: Si vous souhaitez un peu plus tard régler la température de consigne à une valeur inférieure à 60°C (140°F), il faut effectuer à nouveau cette procédure.
Dans le cas d’une installation de chauffe-eau en parallèle, il faut effectuer la procédure qui suit pour tous les autres chauffe-eau (soit, autre que le numéro 1):
1. Déconnectez le contrôleur traducteur du chauffe-eau.
2. Mettez le chauffe-eau à OFF en appuyant sur le bouton d’alimentation de la télécommande.
3. Déplacer à la position ON le micro-interrupteur 4 de la baguette DIP1.
La DEL rouge de la carte électronique se met à clignoter.
4. Maintenez le bouton MAX enfoncé pendant 2 secondes. La DEL rouge reste allumée en continu.
5. Déplacez à la position OFF micro-interrupteur 4 de la baguette DIP1.
6. Coupez l’alimentation électrique du chauffe-eau (déconnectez-le de sa prise murale).
7. Connectez le contrôleur traducteur au chauffe-eau.
8. Reconnectez le chauffe-eau à sa prise murale.
ALERTES
Si le module WiFi EcoNet est configuré correctement, l’utilisateur recevra une notification dans l’application au sujet de l’alerte détectée.
En plus la télécommande pourra afficher les alertes.
Quand une situation d’alerte est détectée, le numéro affiché dans le traducteur va clignoter. Quand cela se produit, l’utilisateur doit se connecter
à l’application de façon à identifier le problème qui a été détecté.
Pour effacer les avertissements ou des alarmes, appuyez sur le bouton gauche sur le traducteur EcoNet pendant 5 secondes jusqu’à ce que tous les segments sur les écrans LED sont allumés. Ensuite, relâchez le bouton et les alarmes seront effacées.
DÉPANNAGE
● Vérifiez que le module WiFi est bien connecté et correctement configuré.
●
Si un défaut est détecté dans un des chauffe-eau connectés à EcoNet, veuillez vous référer à l’application EcoNet pour le dépannage de toutes les alertes de votre chauffe-eau.
● Si la force de votre signal WiFi est insuffisante à l’endroit de votre chauffeeau, vous pourrez encore utiliser le kit WiFi à l’aide de l’amplificateur de portée du WiFi. Contactez votre revendeur de matériel électronique pour plus d’informations.
● Si la connexion est perdue, vérifiez que les voyants sur votre module
WiFi sont allumés et ne clignotent pas. Si ce n’est pas le cas, débranchez puis rebranchez le cordon d’alimentation du module.
●
Contactez le service à la clientèle si un défaut est détecté:
Téléphone: 1-866-720-2076 - Service à la clientèle des chauffe-eau.
1-800-255-2388 - Service à la clientèle pour EcoNet (WiFi)
Site Web: www.Rheem.com/EcoNet.
Code d’erreur
A100
A107
S300
S103
S104
S105
A201
A203
A203
Description Solution
Erreur inconnue du contrôle Tankless
Eau détecté
Détecteur d’eau non installé
Conditions de congélation possibles
Rappel de service
Changer le filtre d’eau
Panne de communication chauffe-eau Traducteur
Erreur de communication
EcoNet
Panne de communication en instance X de chauffeeau
Contacter le service à la clientèle de chauffe-eau.
L’eau est présente à l’intérieur du chauffe-eau, vérifier les fuites ou d’autres sources d’eau.
Vérifier le capteur d’eau est correctement connecté au traducteur EcoNet.
Température Echangeur de chaleur est trop faible.
Rappel amical à avoir votre chauffe-eau desservie. 200 heures de fonctionnement se sont écoulés.
Changer le filtre si vous l’avez installé, sinon ignorer avertissement.
Vérifiez la connexion entre
EcoNet traducteur et chauffe-eau carte de contrôle. Réinitialiser la puissance à l’unité.
Vérifier le câblage EcoNet au module WiFi ou à un autre traducteur EcoNet. Réinitialiser la puissance à l’unité.
Dans le collecteur, vérifier le câblage entre les unités. Réinitialiser la puissance à tous les chauffe-eau.
KIT WiFi ECONET
Instructions d’installation
AVANT DE COMMENCER
● Ce kit EcoNet WiFi est prévu pour être utilisé avec des produits activés pour EcoNet. Essayez NE PAS d’utiliser de kit avec un autre
équipement.
● Le kit EcoNet WiFi nécessite une connexion domestique à Internet
à large bande et un réseau WiFi pour pouvoir fonctionner. Utilisez un téléphone mobile ou un autre appareil disposant du WiFi pour vous assurer que le réseau WiFi domestique est accessible depuis l’emplacement du chauffe-eau.*
Fig. 1
ÉTAPE 1: Notez l’adresse MAC.
●
Repérez l’adresse MAC au dos de votre module comme c’est illustré en
Sample
MAC Address: _____-_____-_____-_____-_____-____
Fig. 1
Exemple
Emplacement de l’adresse
MAC de commande d’accès au support
ÉTAPE 2: Connectez le câble de communication.
●
Insérez une extrémité du câble de communication dans le jack RJ25 qui se trouve en bas du module WiFi comme c’est montré en Figure 2.
Fig. 2
●
Fig. 2 câble de communication dans un des ports EcoNet sur votre traducteur
EcoNet.
Muestra
Ubicación de la dirección del
Control de Acceso a Medios (MAC)
● Remettez en place le couvercle frontal et branchez électriquement le chauffe-eau.
ÉTAPE 3: Fixez le module WiFi de façon permanente.
● Assurez-vous que les deux fiches RJ25 du câble de communication sont bien insérées comme décrit précédemment.
●
Pelez le papier de protection sur une face de la bande adhésive et collezla au dos du module WiFi au-dessus de l’étiquette portant son adresse
MAC.
Fig. 3
● Choisissez un emplacement de votre choix à l’intérieur pour fixer le module WiFi, qui ne cause pas de tension importante au câble de communication.
● Ôtez le papier de protection de la face restante de la bande adhésive et pressez le module contre une surface plane et propre du chauffe-eau, comme c’est montré en Figure 3 pour des modèles d’intérieur.
Fig. 3
● Le module WiFi et le connecteur d’alimentation doivent être situés à l’intérieur.
ÉTAPE 4: Installez le cordon d’alimentation.
● Installez le cordon d’alimentation dans le jack d’alimentation en bas du module, et branchez le transformateur de l’autre côté sur une prise secteur.
Fig. 5
Middle LED indicates
WiFi connection.
Lower LED indicates an active
●
The WLAN SETUP button is used to reset the WiFi sur le réseau domestique [NOTE : Dans cette configuration le module
Le voyant DEL supérieur indique l’alimentation et la connexion à l’équipement.
Le voyant DEL du milieu indique une connexion WiFi.
Le voyant DEL inférieur indique une connexion active au nuage/serveur.
Le bouton WLAN SETUP
(CONFIGURATION DU RÉSEAU
LOCAL SANS FIL) sert à réinitialiser la configuration/ connexion WiFi.
● Fig. 5
La luz LED superior indica
● Assurez-vous que vous possédez bien votre adresse MAC relevé à l’étape 1 précédente.
al equipo.
●
En étant à proximité du module WiFi, ouvrez l’application EcoNet et
La luz LED central indica
Conseil additionnel conexión por WiFi.
La luz LED inferior indica que hay una conexión activa a la nube/ servidor.
El botón WLAN SETUP se usa para reconfigurar la conexión/ configuración por WiFi.
à ses paramètres d’usine par défaut. Après cet appui, les trois voyants à DEL vont commencer à clignoter simultanément, pour indiquer que le module a bien été restauré.
Fig. 5
Top LED indicates power and connection to equipment.
Middle LED indicates
WiFi connection.
Lower LED indicates an active connection to the cloud/server.
The WLAN SETUP button is used to reset the WiFi configuration/connection.
Fig. 5
Le voyant DEL supérieur indique l’alimentation et la connexion à l’équipement.
Le voyant DEL du milieu indique une connexion WiFi.
Fig. 5
Top LED indicates power and connection to equipment.
Fig. 1
ECONET WiFi KIT
Intrucciones de instalación
ANTES DE COMENZAR
El Kit de WiFi EcoNet está diseñado para su uso con productos habilitados para EcoNet. NO intente utilizar este kit con otros equipos.
El Kit de WiFi EcoNet requiere para operar una red de WiFi y conexión a Internet doméstica de banda ancha. Utilice un teléfono celular u otro dispositivo compatible con WiFi para asegurarse de que la red de WiFi del hogar esté accesible desde la ubicación del calentador de agua.*
Sample
Media Access Control (MAC)
Address location
Fig. 1
Exemple
MAC de commande d’accès au support foto digital con un dispositivo móvil, o escríbala en el espacio siguiente.
Dirección MAC: _____-_____-_____-_____-_____-____
Fig. 1
Muestra
Ubicación de la dirección del
Control de Acceso a Medios (MAC)
PASO 2: Conecte el cable de comunicación.
● Inserte un extremo del cable de comunicación en el conector hembra que se encuentra en el fondo del módulo WiFi, como se ilustra en la Figura 2.
Fig. 2
Fig. 2
Retire la cubierta frontal del calentador de agua e inserte el otro extremo del cable de comunicación en uno de los puertos EcoNet de su EcoNet
Translator.
PASO 3: Haga la conexión permanente del módulo WiFi.
Asegúrese de que ambos enchufes del cable de comunicación estén conectados firmemente, como se describió antes.
Seleccione una ubicación para fijar el módulo WiFi en la ubicación interior de su preferencia que no cause una tensión severa en el cable de comunicación.
Retire el papel protector del lado restante de la cinta adhesiva, y oprima el módulo contra una superficie plana y limpia del calentador de agua, como se ilustra en la Figura 3 de modelos para interiores.
Fig. 3
El módulo WiFi y el conector de alimentación deben colocarse en interiores.
PASO 4: Instale el cable de alimentación.
Instale el cable de alimentación en el conector hembra de alimentación que está en el fondo del módulo, y enchufe el transformador a una fuente de alimentación.
Le voyant DEL inférieur indique une connexion active au nuage/serveur.
Le bouton WLAN SETUP
(CONFIGURATION DU RÉSEAU
LOCAL SANS FIL) sert à réinitialiser la configuration/
En este estado, el módulo está funcionando como Punto de acceso de
WiFi].
connexion WiFi.
Fig. 5
La luz LED superior indica corriente eléctrica y conexión al equipo.
La luz LED central indica conexión por WiFi.
SMARTEC ECONET
TRADUCTEUR KIT
Instructions d’installation
Ce chauffe-eau comporte un traducteur SMARTEC EcoNet installé à l’avance. Référez-vous aux instructions qui suivent pour la mise en œuvre du traducteur et du module WiFi.
ATTENTION : Débranchez l’alimentation électrique avant d’intervenir sur le chauffe-eau.
Avertissement : Le module WIFI a besoin d’être installé à l’intérieur.
MISE EN SERVICE EN AUTONOME
1. Si un seul chauffe-eau à gaz sans réservoir est connecté au bus EcoNet, vous pouvez maintenant démarrer l’utilisation du traducteur SMARTEC
EcoNet pour surveiller et contrôler la température de l’eau de ce chauffeeau via l’application EcoNet (voir les instructions pour WiFi).Attendre 60 secondes apies la mise sous tension pour utiliser votre appareil.
La luz LED inferior indica que hay una conexión activa a la nube/ servidor.
El botón WLAN SETUP se usa para reconfigurar la conexión/ configuración por WiFi.
Si todavía no lo ha hecho, descargue la aplicación gratuita EcoNet App del Apple App Store o Google Play Store.
Mientras esté cerca del módulo WiFi, abra la aplicación EcoNet y siga las instrucciones presentadas dentro de la aplicación.
NOTA: Algunos dispositivos móviles pueden fallar en el reinicio de la aplicación EcoNet después de realizar el primer paso de la conexión a la red. A fin de continuar la instalación, regrese manualmente a la aplicación EcoNet y siga las instrucciones restantes.
Consejo adicional
Para repetir el proceso de configuración o cambiar la configuración de conexión a Internet en cualquier momento, no tiene más que oprimir el botón
CONFIGURACIÓN DE WLAN (WLAN SETUP) del módulo WiFi. Esto hará regresar el módulo a sus valores predeterminados de fábrica. Una vez oprimido el botón, los tres LED comenzarán a destellar simultáneamente, indicando que el módulo se ha reiniciado.
2. L’utilisateur peut activer/désactiver le chauffe-eau et régler/visualiser la température de l’eau en sortie à l’aide de la télécommande branchée sur l’appareil ou en liaison sans fil par l’application EcoNet.
MISE EN SERVICE AVEC COLLECTEUR
Si plusieurs chauffe-eau sont interconnectés en configuration de collecteur, poursuivez avec cette section. Sinon vous pouvez passer directement à la section sur les Alertes.
1. Ôtez le couvercle frontal du chauffe-eau.
2. Pour permettre au traducteur SMARTEC EcoNet de contrôler des chauffe-eau à gaz sans réservoir dans une configuration à collecteur, chaque appareil connecté doit être relié à un traducteur SMARTEC
EcoNet.
3. Reliez les chauffe-eau du même collecteur en série en utilisant un ou les deux ports EcoNet situés sur le traducteur EcoNet et le câble RJ25 fourni.
4. Entrez dans le menu de configuration en appuyant en même temps sur les deux boutons du traducteur SMARTEC EcoNet pendant 5 secondes.
Normalement vous devrez voir “1” au lieu de “01” sur l’affichage.
5. Appuyez sur le bouton de droite pour modifier le numéro attribué à chaque chauffe-eau. Le numéro affiché va augmenter à chaque appui sur le bouton.
6. EChaque chauffe-eau sur le collecteur doit être numéroté en séquence.
Cela veut dire que si l’utilisateur a 4 chauffe-eau interconnectés en mode par collecteur, ils doivent être numérotés respectivement 01, 02, 03 et
04. Le nombre maximal de chauffe-eau sur un même collecteur est de 20.
Pour revenir au menu principal appuyez sur le bouton de gauche.
7. Connectez la télécommande incluse avec le chauffe-eau uniquement sur l’appareil numéro 01 dans cette configuration de collecteur. Cette télécommande du 01 va contrôler tous les chauffe-eau interconnectés.
8. L’utilisateur peut activer/désactiver le chauffe-eau et régler/visualiser la température de l’eau en sortie à l’aide de la télécommande branchée sur l’appareil 01 ou en liaison sans fil par l’application EcoNet.
L’appui sur le bouton de gauche fait défiler les articles du menu. L’appui sur le bouton de droite sélectionne l’article du menu et modifie le choix du menu comme suit:
Rubrique du menu Fonction
Nombre de chauffe-eau au collecteur
(1-20), 1 = Pas de fonctionnement en mode collecteur
3 Mode de Recirculation 0= éteindre, 1=allumer
Vous sortez du menu après 10 secondes s’il n’y a pas eu d’action sur un des boutons. Les changements seront sauvegardés dès la sortie du menu.
9. Seul le chauffe-eau numéro 01 aura l’article 2 du menu de disponible.
Cette rubrique du menu indique au gestionnaire du collecteur (numéro
01) combien de chauffe-eau sont connectés au système de collecteur.
10. L’appui sur le bouton de droite en étant à la rubrique 2 du menu augmentera le nombre d’appareils interconnectés que le gestionnaire détectera.
Une fois que tous les chauffe-eau sur le collecteur sont correctement numérotés, la configuration sera terminée, redémarrez votre systéme et attendre 60 secondes avant de commencer.
* Tous les interrupteurs des régulateurs de chauffe-eau doivent être en position d’arrêt.
INSTALLATION AVEC POMPE DE RECIRCULATION
Si votre système de production et de distribution d’eau chaude est équipé d’une pompe de recirculation, veuillez configurer votre chauffe-eau selon la procédure qui suit.
CHAUFFE-EAU EN PARALLÈLE (3 et +)
Utiliser l’option de menu 3 pour activer le mode de recirculation, seulement sur votre chauffe-eau auquel a été assignée la position
1. Ne touchez pas aux micro-interrupteurs des autres appareils de votre groupe de chauffe-eau. Une fois la modification effectuée, coupez l’alimentation électrique (prise murale) et réalimentez tous les chauffe-eau de votre groupe.
CHAUFFE-EAU INDIVIDUE
Utiliser l’option de menu 3 pour activer le mode de recirculation.
Une fois la modification effectuée, coupez l’alimentation électrique
(prise murale) du chauffe-eau et réalimentez-le.
Remarque: Le mode de recirculation est destiné à des configurations de 3 unités ou plus.
SÉLECTION DU RÉGLAGE HAUTE TEMPÉRATURE
Si votre chauffe-eau est équipé d’une carte commerciale qui est en mesure de produire de l’eau chaude pour la désinfection (à une température de 85°C/185°F), suivez la procédure qui suit pour configurer l’interface traducteur EcoNet. La procédure qui suit concerne les chauffe-eau individuel et votre chauffe-eau en parallèle auquel a été assignée la position 1.
Alors que le chauffe-eau est alimenté en électricité:
1. Changez la température de consigne à 100 ° F à l’aide de la télécommande ou l’application EcoNet. Attendre 10 secondes.
2. Déconnectez le traducteur du chauffe-eau.
3. Mettez le chauffe-eau à l’arrêt en appuyant sur le bouton d’alimentation de la télécommande murale.
4. Sur la carte électronique de votre chauffe-eau, déplacer à la position ON le micro-interrupteur 4 de la baguette DIP1 (reportezvous au manuel d’utilisation et d’entretien de votre chauffe-eau). La télécommande se met à clignoter.
5. Maintenez le bouton Max enfoncé pendant 2 secondes.
6. Déplacez à la position OFF le micro-interrupteur 4 de la baguette DIP1.
7. Appuyez sur le bouton d’alimentation de la télécommande.
8. Connectez le contrôleur traducteur au chauffe-eau.
9. Attendez pendant 60 secondes.
10. Changez la température de consigne jusqu’à la valeur voulue.
Note: Si vous souhaitez un peu plus tard régler la température de consigne à une valeur inférieure à 60°C (140°F), il faut effectuer à nouveau cette procédure.
Dans le cas d’une installation de chauffe-eau en parallèle, il faut effectuer la procédure qui suit pour tous les autres chauffe-eau (soit, autre que le numéro 1):
1. Déconnectez le contrôleur traducteur du chauffe-eau.
2. Mettez le chauffe-eau à OFF en appuyant sur le bouton d’alimentation de la télécommande.
3. Déplacer à la position ON le micro-interrupteur 4 de la baguette DIP1.
La DEL rouge de la carte électronique se met à clignoter.
4. Maintenez le bouton MAX enfoncé pendant 2 secondes. La DEL rouge reste allumée en continu.
5. Déplacez à la position OFF micro-interrupteur 4 de la baguette DIP1.
6. Coupez l’alimentation électrique du chauffe-eau (déconnectez-le de sa prise murale).
7. Connectez le contrôleur traducteur au chauffe-eau.
8. Reconnectez le chauffe-eau à sa prise murale.
ALERTES
Si le module WiFi EcoNet est configuré correctement, l’utilisateur recevra une notification dans l’application au sujet de l’alerte détectée.
En plus la télécommande pourra afficher les alertes.
Quand une situation d’alerte est détectée, le numéro affiché dans le traducteur va clignoter. Quand cela se produit, l’utilisateur doit se connecter
à l’application de façon à identifier le problème qui a été détecté.
Pour effacer les avertissements ou des alarmes, appuyez sur le bouton gauche sur le traducteur EcoNet pendant 5 secondes jusqu’à ce que tous les segments sur les écrans LED sont allumés. Ensuite, relâchez le bouton et les alarmes seront effacées.
DÉPANNAGE
● Vérifiez que le module WiFi est bien connecté et correctement configuré.
●
Si un défaut est détecté dans un des chauffe-eau connectés à EcoNet, veuillez vous référer à l’application EcoNet pour le dépannage de toutes les alertes de votre chauffe-eau.
● Si la force de votre signal WiFi est insuffisante à l’endroit de votre chauffeeau, vous pourrez encore utiliser le kit WiFi à l’aide de l’amplificateur de portée du WiFi. Contactez votre revendeur de matériel électronique pour plus d’informations.
● Si la connexion est perdue, vérifiez que les voyants sur votre module
WiFi sont allumés et ne clignotent pas. Si ce n’est pas le cas, débranchez puis rebranchez le cordon d’alimentation du module.
●
Contactez le service à la clientèle si un défaut est détecté:
Téléphone: 1-866-720-2076 - Service à la clientèle des chauffe-eau.
1-800-255-2388 - Service à la clientèle pour EcoNet (WiFi)
Site Web: www.Rheem.com/EcoNet.
Code d’erreur
A100
A107
S300
S103
S104
S105
A201
A203
A203
Description
Erreur inconnue du contrôle Tankless
Eau détecté
Détecteur d’eau non installé
Conditions de congélation possibles
Rappel de service
Changer le filtre d’eau
Panne de communication chauffe-eau Traducteur
Erreur de communication
EcoNet
Panne de communication en instance X de chauffeeau
Solution
Contacter le service à la clientèle de chauffe-eau.
L’eau est présente à l’intérieur du chauffe-eau, vérifier les fuites ou d’autres sources d’eau.
Vérifier le capteur d’eau est correctement connecté au traducteur EcoNet.
Température Echangeur de chaleur est trop faible.
Rappel amical à avoir votre chauffe-eau desservie. 200 heures de fonctionnement se sont écoulés.
Changer le filtre si vous l’avez installé, sinon ignorer avertissement.
Vérifiez la connexion entre
EcoNet traducteur et chauffe-eau carte de contrôle. Réinitialiser la puissance à l’unité.
Vérifier le câblage EcoNet au module WiFi ou à un autre traducteur EcoNet. Réinitialiser la puissance à l’unité.
Dans le collecteur, vérifier le câblage entre les unités. Réinitialiser la puissance à tous les chauffe-eau.
KIT WiFi ECONET
Instructions d’installation
AVANT DE COMMENCER
Ce kit EcoNet WiFi est prévu pour être utilisé avec des produits activés pour EcoNet. Essayez NE PAS d’utiliser de kit avec un autre
équipement.
Le kit EcoNet WiFi nécessite une connexion domestique à Internet
à large bande et un réseau WiFi pour pouvoir fonctionner. Utilisez un téléphone mobile ou un autre appareil disposant du WiFi pour vous assurer que le réseau WiFi domestique est accessible depuis l’emplacement du chauffe-eau.*
Fig. 1
ÉTAPE 1: Notez l’adresse MAC.
Repérez l’adresse MAC au dos de votre module comme c’est illustré en
Sample
MAC Address: _____-_____-_____-_____-_____-____
Fig. 1
Exemple
Emplacement de l’adresse
MAC de commande d’accès au support
ÉTAPE 2: Connectez le câble de communication.
Insérez une extrémité du câble de communication dans le jack RJ25 qui se trouve en bas du module WiFi comme c’est montré en Figure 2.
Fig. 2
Fig. 2 câble de communication dans un des ports EcoNet sur votre traducteur
EcoNet.
Muestra
Ubicación de la dirección del
Control de Acceso a Medios (MAC)
Remettez en place le couvercle frontal et branchez électriquement le chauffe-eau.
ÉTAPE 3: Fixez le module WiFi de façon permanente.
Assurez-vous que les deux fiches RJ25 du câble de communication sont bien insérées comme décrit précédemment.
Pelez le papier de protection sur une face de la bande adhésive et collezla au dos du module WiFi au-dessus de l’étiquette portant son adresse
MAC.
Fig. 3
Choisissez un emplacement de votre choix à l’intérieur pour fixer le module WiFi, qui ne cause pas de tension importante au câble de communication.
Ôtez le papier de protection de la face restante de la bande adhésive et pressez le module contre une surface plane et propre du chauffe-eau, comme c’est montré en Figure 3 pour des modèles d’intérieur.
Fig. 3
Le module WiFi et le connecteur d’alimentation doivent être situés à l’intérieur.
ÉTAPE 4: Installez le cordon d’alimentation.
Installez le cordon d’alimentation dans le jack d’alimentation en bas du module, et branchez le transformateur de l’autre côté sur une prise secteur.
Middle LED indicates
WiFi connection.
Lower LED indicates an active is used to reset the WiFi sur le réseau domestique [NOTE : Dans cette configuration le module
Fig. 5
Le voyant DEL supérieur indique l’alimentation et la connexion à l’équipement.
Le voyant DEL du milieu indique une connexion WiFi.
Le voyant DEL inférieur indique une connexion active au nuage/serveur.
Le bouton WLAN SETUP
(CONFIGURATION DU RÉSEAU
LOCAL SANS FIL) sert à réinitialiser la configuration/ connexion WiFi.
Fig. 5
La luz LED superior indica l’étape 1 précédente.
corriente eléctrica y conexión al equipo.
En étant à proximité du module WiFi, ouvrez l’application EcoNet et
La luz LED central indica conexión por WiFi.
La luz LED inferior indica que hay una conexión activa a la nube/ servidor.
Conseil additionnel
El botón WLAN SETUP se usa para reconfigurar la conexión/ configuración por WiFi.
à ses paramètres d’usine par défaut. Après cet appui, les trois voyants à DEL vont commencer à clignoter simultanément, pour indiquer que le module a bien été restauré.
advertisement
Key Features
- Endless hot water on demand, eliminating the need for a storage tank
- High-efficiency operation, reducing energy consumption and utility bills
- Compact design, saving valuable space in your home or business
- Digital temperature control, allowing for precise adjustment of water temperature
- Advanced safety features, including overheat protection and freeze protection
- Easy installation and maintenance, making it convenient and cost-effective to own
Frequently Answers and Questions
Is the Rheem ECO180DVELN3-1 suitable for use in manufactured homes?
What are the safety precautions to follow when using the Rheem ECO180DVELN3-1?
How do I set the water temperature on the Rheem ECO180DVELN3-1?
What is the recommended maintenance schedule for the Rheem ECO180DVELN3-1?
How do I troubleshoot common problems with the Rheem ECO180DVELN3-1?
Related manuals
advertisement
Table of contents
- 8 Safety Precautions
- 8 Product Information
- 10 Specifications
- 12 General Descriptions
- 14 Setting the Water Temperature
- 16 Water Heater Inspections
- 18 Care and Cleaning
- 19 Preventive Maintenance
- 22 Draining the Water Heater
- 22 Freeze Protection
- 23 Vacation and Extended Shutdown
- 24 Troubleshooting Chart
- 26 Service Error Code Chart
- 26 Call for Assistance
- 28 Standards Compliance
- 29 Choosing a Location
- 30 Product Inspection
- 33 Water Heater Installation
- 45 Venting
- 50 Water Quality/Supply
- 55 Gas Supply
- 59 Electrical Wiring
- 59 Remote Control Installation
- 60 Insulation Blankets and Installation Precautions
- 61 Installation Checklist
- 62 Piping for Space Heaters
- 63 Recirculation Control
- 66 Activating the Water Heater
- 67 Operating Instructions
- 70 Setting the Water Temperature
- 71 High-Altitude Dip Switch Adjustments
- 73 Water Saving Control Option
- 75 Maintenance Notice Option
- 77 Parts Ordering
- 80 Warranty Information